How to use #(99)( ALL1) input data procedure (include OPTION).

Press Emergency The following two methods can be used to stop the PLC.
Start your NC
stop again.
buttom. 1) Stopping with rotary switch
Set the rotary switch: ”NC SYS” (on NC bottom
NO
looking from front) on the top of the unit to “1”.
Stop user PLC.
2) Stopping with PLC onboard
Press F0 , FILE and 4RUN/STOP keys,and input
“1”.
Into the SETUP PARAM 2/14 screen .
Input #(1060)DATA(64)(S) .And click “input”
This parameter is to open your OPTION
two times.
parameter screen.

Press “TOOL PARAM”menu key.

Press “DIAG IN/OUT”menu key.


Confirm input/output device connection.

Select INPUT screen

#(99) DATA( ) Setting and click “INPUT”. Then select ALL1 parameter file and start
your computer input .

Start data input.

“DATA IN COMPLETE” finish input.

Turn off your NC power. Start your NC again.

Into the SETUP PARAM 2/14 screen .


Input #(1060)DATA(64)(S) .And click “input”
two times.

Press “TOOL PARAM”menu key.


You can see your NC option value screen.

YES
Data in completion