D. Operation procedure
The data is backed up and restored by using BACKUP screen .
Refer following procedure for details on operations.
NO : "N" "INPUT"
#( )
Input "Y" in the setting area # ( ), and press the INPUT key. The BACKUP screen will open.
[BACKUP] PARAM 3
The date and time that the backup data was saved, and the serial No. are displayed on this screen.
48
1. M60 / M60S Series
1.5 How to backup / recover /replace the NC unit
The parameters are backed up in the maintenance memory cassette with the following steps.
(1)
Execute emergency stop.
#( ) ( )
"EMG EMERGENCY" will appear at the EMG EMERGENCY
operation message area.
WORK PROCESS I/O PAR SETUP MENU
(2)
Input "1" at the setting area # ( ),
and press the INPUT key. #(1) ( ) PLC STOP Y/N
EMG EMERGENCY
"PLC STOP Y/N" will appear at the
WORK PROCESS I/O PAR SETUP MENU
message area.
(3)
Input "Y" at the setting area ( ),
and press the INPUT key. #(1) ( Y) BACKUP EXEC Y/N
EMG EMERGENCY
"BACKUP EXEC Y/N" will appear at the WORK PROCESS I/O PAR SETUP MENU
message area.
(4)
Input "Y" at the setting area ( ),
and press the INPUT key. #(1) ( Y) BACKUP EXECUTION
EMG EMERGENCY
(a) The message "BACKUP EXECUTION"
WORK PROCESS I/O PAR SETUP MENU
will appear while the parameters are
being backed up.
#( ) ( ) BACKUP COMPLETE
EMG EMERGENCY
WORK PROCESS I/O PAR SETUP MENU
49
1. M60 / M60S Series
1.5 How to backup / recover /replace the NC unit
The parameters are restored from the maintenance memory cassette to the NC with the following steps.
(1)
Execute emergency stop.
#( ) ( )
"EMG EMERGENCY" will appear at the EMG EMERGENCY
operation message area.
WORK PROCESS I/O PAR SETUP MENU
(2)
Input "2" at the setting area # ( ),
and press the INPUT key. #(2) ( ) PLC STOP Y/N
EMG EMERGENCY
"PLC STOP Y/N" will appear at the
WORK PROCESS I/O PAR SETUP MENU
message area.
(3)
Input "Y" at the setting area ( ),
and press the INPUT key. #(2) ( Y) RESTORE EXEC Y/N
EMG EMERGENCY
"RESTORE EXEC Y/N" will appear at WORK PROCESS I/O PAR SETUP MENU
the message area.
(4)
Input "Y" at the setting area ( ),
and press the INPUT key. #(2) ( Y) RESTORE EXECUTION
EMG EMERGENCY
(a) The message "RESTORE EXECUTION"
WORK PROCESS I/O PAR SETUP MENU
will appear while the parameters are
being restored.
50