You are on page 1of 2

SEÑALES TORRETA

X20. 7 6 5 4 3 2 1 0 TP0 TURRET POSITION DETECTED

T1 1 1 1 1 1 1 0 0

T2 1 1 1 1 1 0 1 0

T3 1 1 1 1 0 1 1 0

T4 1 1 1 0 1 1 1 0

T5 1 1 0 1 1 1 1 0

T6 1 0 1 1 1 1 1 0

T7 0 1 1 1 1 1 0 0

T8 0 1 1 1 1 0 1 0

T9 0 1 1 1 0 1 1 0

T10 0 1 1 0 1 1 1 0

T11 0 1 0 1 1 1 1 0

T12 0 0 1 1 1 1 1 0

X22.0 = TURRET IN POS CHECK TIP

X22.1 = TURRET CLAMP CHECK TCP

X22.4 = TURRET IN POSITION CHECK ? O X22.0 ? TIP

R513.5 = TINP

R513.2 = XEQY TOOL No COMPARASION

R514.5 = TOOL CHANGE END ?

R518.0 = T11Y TOOL No DECODING

TIMER TM9 D350 =11 XEQY TOOL No COMPARASION DELAY (150MS) R521.0

TIMER TM10 D355=101 TEN TOOL CHANGE CONFIRM DELAY (250 MS)

TIMER TM 11 D360= 11110000 TOOL CHANGE LAP TIME (12 SEC)

SENSOR PEQUEÑO DE TORRETA VA A ENTRADA 08 DEL PLC = REDUCE SPEED?

X22.2 = TURRET UNCLAMP CHECK SOLENOIDE TUC

Y52.5= TURRET CW ? SOLENOIDE TCW

Y52.6= TURRET CCW ? SOLENOIDE TCCW


Y52.7 = TURRET REDUCTION SPEED ? TSR SOLENOIDE TRD

Y53.3= TURRET HIGH SPEED? THS SOLENOIDE THD

R513.7 = MFW MOTOR FREE

R514.7 = TEN TURRET UNCLAMP CONFIRM

R520.4=(150MS) MOTOR FREE WHEELING

TIMER TM5 DELAY MFW? D330=11? (150MS) MOTOR FREE WHEELING R520.4