Professional Documents
Culture Documents
10-1 10 cm
Cutting efficiency of soft tissue and haemostasis is supe- 10-2 1m
rior to any known alternative. Saline or water is used 10-3 10 m
for irrigation reducing the risk of TUR Syndrom [2]. 10-4 100 m
0,1 0,5 1 2 3 10 100
Excess laser radiation is absorbed by the irrigation and Wavelength [µm]
does not affect tissue more than 3 mm from the tip of
the fibre. Tissue damage is limited to 0.2 to 1.5 mm
depending on laser power. Absorbtion spectra of body chromophores
Visualization is excellent. Neither bleeding nor visible This graph shows the absorption of the most important
laser glare affects the vision of the surgical site. Colour body chromophores (RED for blood, BLUE for water,
neutral laser safety glasses maintain true colours. Endo- BROWN for melanin) at different wavelengths. Depth
scope lenses remain free from splatter when used in of penetration is shown at the right. Laser wavelengths
laparoscopic surgery. are shown as vertical lines.
Green laser: In the absence of haemoglobin the Green
laser at 532 nm experiences close to no absorption in
RevoLix – what are the benefits ? tissue because at this wavelength water as the main
J No blood loss, no transfusions body constituent is almost transparent. Under laser
treatment haemoglobin bleaches due to the tempera-
J Quick recovery ture increase in tissue caused by the laser. This explains
J Short hospital stay the ever decreasing ablation efficiency during a Green
laser treatment.
J Less postoperative care
J Short catheterisation time in BPH treatment Diode laser: At Diode laser wavelength neither water
nor haemoglobin is a good absorber. This explains
J Precise surgery the deep penetration of diode lasers and the Nd:YAG
J No deep tissue penetration laser.
J Safe operation RevoLix and Holmium laser: Both lasers are of similar
wavelength which is selectively absorbed by the water
J Excellent haemostasis molecule. The optical penetration of RevoLix in tissue
J Treatment of patients under anticoagulant is app. ¼ mm [13].
J Ejaculation protective BPH surgery Unlike than haemoglobin water retains its absorptive
J Multi-disciplinary properties under the temperature increase in tissue
caused by any laser. This explains the everlasting tis-
sue effect during RevoLix treatment.
WHY REVOLIX
at the transition
0.
Histology of excised prostatic tissue after vaporization with RevoLix 200 watt laser will progress cutting chips which increase in size and
3
m
m
Nuclear morphology
finally ending up in enucleation – all with the same
ap
p.
ap
at the transition
0.
p.
instrument.
3
1.
m
0
m
m
m
Pycnotic nuclei
Throughout the learning curve there is no additional
ap
p.
1.
Pycnotic nuclei
is longer [12].
Tissue samples are produced for subsequent histologi-
Healthy nuclear morphology cal examination during Vaporesection and Enucleation.
RevoLix for BPH surgery is efficient and safe [6].
Healthy nuclear morphology
Urology
VapoResection of prostate (ThuVaRP)
Vaporisation of Prostate (ThuVAP)
VapoEnucleation of prostate (ThuVEP)
Enucleation of prostate (ThuLEP)
Va p
r
Va
te
ou
Ex
Re or sio
e
Bladder neck incision
sta
st tu
p
is a
ci
m
ro
at
o
se c ti o n o f Pr o no
Opening of strictures ti o n o f p f kid n ey
Vaporisation and excision of bladder tumours
Partial nephrectomy
Laparoscopy
Lithotripsy
U re
t e r st o n e
Gynaecology
Excision of polyps
Endometriosis
Hysterectomy
Adhesiolysis
Conisation
Condylomata Ad
h e sio l ysis
Myomectomy
Neurosurgery**
Fenestration of cysts
Ventriculocysternosomy
Catheter recovery Ve y
3rd ventriculostomy M ISS n t ri c u l o s t o m
Tumour resection
Haemostasis
ENT
Excision of tumours
Tonsillectomy xz
To y ou
E
is i o
r
Conchotomy
n s il l e c t o m y n of tu m
Pneumology
Bronchoscopy
Airway recanalization
Desobstruction
n
Ai
wa t
io
Technical Specifications
120/20-Watt-Laser
RevoLix ™
150/20-Watt-Laser*
x
Tissue laser system continuous wave DPSS laser
Wavelength 2013 nm
Power at fibre tip 5 - 120 W (adjustable) 5 - 150 W (adjustable)
Emission mode continuous wave, chopped 50 ms - 1000 ms
IMPORTANT NOTICE:
Safety Standards: IEC 60601
*CE approval pending The information provided is a general overview of
potential clinical applications of the described products.
U.S. federal law restricts this device
to sale by or on the order of a phy- National health care regulations vary between
sician. countries and may exclude certain clinical applica-
tions at your location. The user assumes responsi-
Specifications are subject to change bility to be updated about national deviations from
without notice. the applications listed above.
Made in Germany 2016-06 **In the USA the products are not intended for use
Brochure Part No. 036 002 100 in clinical applications in neurosurgery.