Professional Documents
Culture Documents
(Remember)
*************************************************************************************
Assignment No 2
[Total No. of Questions = 1 ] [Total No. of Pages = 1 ]
Halogen lamp
Induction lamp
HPMV lamp
HPSV lamp
LPSP lamp
LPMV lamp
LED
*************************************************************************************
Assignment No 3
[Total No. of Questions = 3 ] [Total No. of Pages = 1 ]
Q.2 Classify the light fitting according to way the light reaches the object. [7 ]
Q.3 Define luminaries as per IEC. What are the design factors for the [6 ]
illumination
*************************************************************************************
**
Assignment No 4
[Total No. of Questions = 3 ] [Total No. of Pages = 1 ]
B.E. (Electrical) 2012-Course
Subject Code:403143 Subject Name:Illumination Engineering
Semester: II (2017-18)
[Time: 1 Hours] [Max Marks = 20 ]
Instructions to Candidates:
• All Questions are compulsory.
• Use of Scientific calculator is allowed.
Q.2 An engineering institutes drawing hall 30m x 13m with a ceiling height of 5m [7 ]
is to be provided with a general illumination of 120lux. Taking a coefficient of
utilization of 0.5 and depreciation factor of 1.4, determine the number of
fluorescent tubes required, their spacing mounting height and total wattage.
Taking luminous efficiency of fluorescent tube as 40lumen/watt for 80 watt
tube.
Q.3 [6 ]
*************************************************************************************
**
Assignment No 5
[Total No. of Questions = 2 ] [Total No. of Pages = 1 ]
Q. 1 Two lamp posts are 10m apart and fitted with 100cp lamp each at the [10 ]
height of 5m of above ground calculate illumination
*************************************************************************************
**
Assignment No 6
[Total No. of Questions = 3 ] [Total No. of Pages = 1 ]