You are on page 1of 2

Installation Button Guide Symbol Guide Start up Perform Reset/Homing Memory Positions Setting Memory Positions 1 – 3 Accessing Memory

Start up Perform Reset/Homing Memory Positions Setting Memory Positions 1 – 3 Accessing Memory Positions 1 – 3
Attach the handset to the underside of the Explanation of the display Once connected, a height read-out should Critical step. At installation or if a critical com- Set/Adjust a quick memory position. There
User manual for table top using the two provided screws. If - Adjust the table upwards appear on the display. ponent such as a column or motor is changed is a quick memory position option to set the
or Move the table to desired height Hold the M button for at least
3 seconds
Flow Visual Handset the work surface thickness is less than 18 mm
(3/4”) use shorter screws (not provided).
- Scroll up when in the Menu
73 8 Start-up indications
or disconnected, a Reset must be performed.

NOTE! Ensure that the area around and under


Up and Down buttons to move the desk to a
predefined height. To set the predefined height
for a button:
Hold the M button for at least 3
seconds 1, 2 OR 3 Use the Up or Down button to
choose stored position 1, 2 or 3
Use the Down button to navigate
- Adjust the table downwards the table are clear. to SET Press and hold the M button while
- Scroll down when in the Menu Three dashes the table moves to the stored
Understanding the symbols Adjust the table to the preferred memory position
or

- Menu, to enter Menu mode


- Enter, when in Menu mode
Menu mode

Memory
Imperial, inch

Thermometer
--- and

8 seconds
Press and hold the Up and Down
buttons at the same time

Hold the buttons pressed at least


height to be stored as a memory
position

Press the M button, and release


1, 2 OR 3
Press the M button to select

Use the Up or Down button to


select position to store the height
or with a slave number such as 8 seconds to, 1, 2 or 3.

1
Error codes Metric, centimeter or Immediately press the Up or
Release Release the Up and Down buttons Down button to store the current Press the M button to save
height as a quick memory posi- current height
Reset 73 8 Height reading
Immediately press and hold tion to the selected button
Homing mode
Height reading the Down button - the display
will indicate reset mode with

Connect 15 sec – sleep mode


73 8 ---
three dashes and a house in the
lower left corner - until the desk
reaches its lowest position and
stops moving
Use preset heights

or Press and hold either the Up or


Down button to move the desk
Display backlight will go to sleep mode after Release Release the Down button to the quick memory position,
Connect the handset cable to one of the 15 seconds of inactivity. the desk will stop at the preset
Height The three dashes on the display height. Release the button.
columns connector ports. The second port
reading will be replaced by a height
on the handset can be used to connect other reading Press and hold the same button
or
devices. as previously to bypass the desks
Complete The reset process is completed preset height.

2 3 4 5 6 7 8 9
Calibrate Upper Limit Lower Limit Units Performing a Forced Reset Software Version Error logs Error codes Actuator Versions
If the height reading displays incorrect height, Set an Upper Limit when planning over-head Set an Lower Limit when planning storage Change between metric or imperial units If Standard Reset (page 6) does not initiate Display Software Version Shows the number of times each error has 1. Hard stop
the height from the table top needs to be storage under the table a reset, perform a Forced Reset occurred since start-up or last reset 2. Back off
calibrated. 3. Soft stop
4. Waiting for button
Measure the distance between the floor and the Press and hold M button for at Press and hold M button for at Press and hold M button for at Press and hold M button for at Press and hold M button for at Press and hold M button for at 5. Waiting for button release Press and hold M button for
top of the table top. least 8 seconds... least 8 seconds... least 8 seconds... least 8 seconds... least 8 seconds... least 8 seconds... 6. Motor lost at least 8 seconds...
7. Overcurrent
...until three dashes are displayed ...until three dashes are displayed ...until three dashes are displayed ...until three dashes are displayed ...until three dashes are displayed ...until three dashes are displayed ...until three dashes are

Press and hold M button for at


--- --- --- --- --- --- 8. Overheating: Thermometer flashing, wait
10 minutes for motor cooling.
--- displayed

least 8 seconds... 9. Low voltage: (under 16vdc)


Release Release the M button Release Release the M button Release Release the M button Release Release the M button Release Release the M button Release Release the M button Release Release the M button
...until three dashes are displayed 10. High voltage: (over 40vdc)
--- U.L. Use the Up or Down button to
navigate to U.L. (Upper Limit) L.L. Use the Up or Down button to
navigate to L.L (Lower Limit)
Use the Up or Down button to
navigate to Un (Units). RES Use the Up or Down button to
navigate to RES. (Reset) SOF Use the Up or Down button
to navigate to SOF (Software
Version)
e Use the Up or Down button to
navigate to Err
11.
12.
Out of sync / legs too far apart
Destination above upper limit A Use the Up or Down button
to navigate to Act (Actuator/
Columns)
Release Release the M button 13. Destination below lower limit
Select by pressing the M button Select by pressing the M button Select by pressing the M button Select by pressing the M button Select by pressing the M button Select by pressing the M button Select by pressing the M
14. Internal error
Use the Up or Down button to button
CAL navigate to CAL (Calibrate)
or Calibrate Upper Limit by using or Calibrate Lower Limit by using CM OR “ Choose CM (centimeter) or “ Activate Reset/Homing by Software Software Version will appear on Navigate with the Up or Down
15. Collision detected by CDS

68006805-A © ROL ERGO AB


the Up or Down buttons the Up or Down button (inch) with the Up or Down pressing the Down button button to the error number you 16. Wrong number of motors connected Latest firm- Latest Firmware Version will
Version the display
button displayed want to view 17. Destination above upper motor limit ware version appear
Select by pressing the M button displayed
Select value and return to Menu Select value and return to Menu 18. Destination below lower motor limit
by pressing the M button by pressing the M button Select value and return to Menu Return to Menu by pressing the Number of After 1 second of inactivity, the
Change the current height read- by pressing the M button times the number of times that error has 19. Slave lost/Disconnected Navigate with the Up or
or M button
ing by using the Up or Down error occurred will display 20. Motor not moving Down button to see the
button to the measured height occoured oldest Firmware Version
displayed
Store the current height reading
and return to Menu by pressing
the M button
Return to Menu by pressing the
M button 3
Default error code
123
Error code 8, flashing
Return to Menu by pressing
the M button

10 11 12 13 14 15 16 example thermometer 18