Replacing BMS-2000 LCD Panel (LCD5)
ECS breaker
4. Remove the LCD Panel, and disconnect the earth lead. Turn over to see the
terminals on the rear panel.
5. Cut off the insulation locks tied with the LCD Panel and the Cables.
Release the mounting lock, and remove the LCD Panel from the Control desk
9. Install the new LCD with the Control Desk, fit the earth lead and set the cover
with the fixing screws.
10. Turn on the breaker ‘ECS’ on the Relay Panel to activate the LCD Panel.
11. Press the SET, and input 7 five times in the password.
12. Follow the procedure below and save all the data.
Ⅰ.Press ‘EPS(F2)’-> Press ‘SAVE(F9)’. After making sure saving the data, press
EXIT (F1) to exit.
Ⅱ.Press ‘ETS(F3)’->Press ‘SAVE(F9)’ ,and then press ‘EXIT(F1)’ to exit.
Ⅲ.Press ‘ECSrpm(F4)’->Press ‘SAVE(F9)’ , and then press ‘EXIT(F1)’ to exit.
Ⅳ.Press ‘ECStime(F5)’-> Press ‘SAVE(F9)’ ,and then press ‘EXIT(F1)’ to exit.
Ⅴ.Press ‘GOVndle(F6)’->Press ‘SAVE(F9)’ and then press ‘EXIT(F1)’ to exit.
Ⅵ.Press ‘GOVothr(F7)’-> Press ‘SAVE(F9)’, and then press ‘EXIT(F1)’ to exit.
Ⅶ.Press ‘SHDSLD(F8)’-> Press ‘SHUTDOWN(F3)’-> Press ‘SAVE’(F9)’ and then
press ‘EXIT(F1)’ to exit.
Ⅷ.Press ‘SLOWDOWN(F4)’->Press ‘SAVE(F9)’ and then press ‘EXIT(F1)’
twice to exit.
Ⅸ.Press ‘CONFIG(F9)’->Press ‘ECS(F3)’-> Press ‘SAVE(F9)’ and then press
‘EXIT(F1)’ to exit.
Ⅹ. Press ‘ETS(F4)’>Press ‘SAVE(F9)’ and then press ‘EXIT(F1)’ three times
to return to General display.
For details, refer to the ‘operation of the LCD panel and setting value’ in the
Instruction Manual 5-1.