Report No.

: BD-M/2212-001
MAGNETIC PARTICLE TESTING REPORT
Page: 1 of 1

Code / Standards: BS-6072-1981 End User: BIEN DONG PETROLEUM OPERATING COMPANY
Test in accordance with: BD-HSE-P- Location: MT1-WHP
0030: Inspection and Certification of Project: 6 MONTH INSPECTION LIFTING GEAR
Lifting Equipment Item: LIFTING GEAR - SHACKLE
Equipment: Yoke MY-2 MPI method Material type: Carbon Steel
Serial No.: 2006011 Visible wet continuous Welding process: N/A
Current: AC MPI ink: Nabakem SM-15 Surface condition: As casted
Pole spacing: 75-150 mm Batch No.: 220621/7 Cleaned by: Brusher
Lifting power: Background contrast: Nabakem MP-35 Lighting condition: daylight (2000 lux)
4.5 KG Batch No.: 220722/1C Date of inspection: Nov.-2022
Field strength assessment: Burmah Castrol Strip
Result
No. Part ID / Serial no. Tested locations Noted Findings Remark
ACC/REJ
1 SH3-12HT All suface Non- Relevant indication ACC -
2 561.0412 All suface Non- Relevant indication ACC -
3 0565.0412MT All suface Non- Relevant indication ACC -
4 568.0412 All suface Non- Relevant indication ACC -
5 25T-1 All suface Non- Relevant indication ACC -
6 BD-SH25-2 All suface Non- Relevant indication ACC -
7 PQP-SH8-02 All suface Non- Relevant indication ACC -
8 BD-SH901 All suface Non- Relevant indication ACC -
9 SH9-11 All suface Non- Relevant indication ACC -
10 PQP-SH12-10 All suface Non- Relevant indication ACC -
11 BD-SH3-4 All suface Non- Relevant indication ACC -
12 05650412MT All suface Non- Relevant indication ACC -
13 5680412 All suface Non- Relevant indication ACC -
Reference photo:

Remark:
Legends: ACC: Accepted REJ: Rejected IC: Intermittent cold lap
C: Crack U: Undercut LP: Lack of penetration
CP: Clustered Porosity CR: Crater crack P: Porosity
LF: Lack of fusion CL: Cold lap SI: Slag inclusion
Inspector / examiner QA/QC Reviewed by client
Name: PHAM QUOC KIET Name: Name:
Signature: Signature: Signature:

Date: 30/11/2022 Date: Date:


Report No.: BD-M/2212-002
MAGNETIC PARTICLE TESTING REPORT
Page: 1 of 1

Code / Standards: BS-6072-1981 End User: BIEN DONG PETROLEUM OPERATING COMPANY
Test in accordance with: BD-HSE-P- Location: MT1-WHP
0030: Inspection and Certification of Project: 6 MONTH INSPECTION LIFTING GEAR
Lifting Equipment Item: LIFTING GEAR - SHACKLE
Equipment: Yoke MY-2 MPI method Material type: Carbon Steel
Serial No.: 2006011 Visible wet continuous Welding process: N/A
Current: AC MPI ink: Nabakem SM-15 Surface condition: As casted
Pole spacing: 75-150 mm Batch No.: 220621/7 Cleaned by: Brusher
Lifting power: Background contrast: Nabakem MP-35 Lighting condition: daylight (2000 lux)
4.5 KG Batch No.: 220722/1C Date of inspection: Nov.-2022
Field strength assessment: Burmah Castrol Strip
Result
No. Part ID / Serial no. Tested locations Noted Findings Remark
ACC/REJ
1 MT1-EB-1 All suface Non-Relevant indication ACC -
2 MT1-EB-3 All suface Non-Relevant indication ACC -
3 MT1-EB-4 All suface Non-Relevant indication ACC -
4 MT1-EB-5 All suface Non-Relevant indication ACC -
5 MT1-EB-6 All suface Non-Relevant indication ACC -
6 MT1-EB-7 All suface Non-Relevant indication ACC -
7 MT1-EB-8 All suface Non-Relevant indication ACC -
8 MT1-EB-9 All suface Non-Relevant indication ACC -
Reference photo:

Remark:
Legends: ACC: Accepted REJ: Rejected IC: Intermittent cold lap
C: Crack U: Undercut LP: Lack of penetration
CP: Clustered Porosity CR: Crater crack P: Porosity
LF: Lack of fusion CL: Cold lap SI: Slag inclusion
Inspector / examiner QA/QC Reviewed by client
Name: PHAM QUOC KIET Name: Name:
Signature: Signature: Signature:

Date: 30/11/2022 Date: Date:


Report No.: BD-M/2212-003
MAGNETIC PARTICLE TESTING REPORT
Page: 1 of 1

Code / Standards: BS-6072-1981 End User: BIEN DONG PETROLEUM OPERATING COMPANY
Test in accordance with: BD-HSE-P- Location: MT1-WHP
0030: Inspection and Certification of Project: 6 MONTH INSPECTION LIFTING GEAR
Lifting Equipment Item: LIFTING GEAR - SHACKLE
Equipment: Yoke MY-2 MPI method Material type: Carbon Steel
Serial No.: 2006011 Visible wet continuous Welding process: N/A
Current: AC MPI ink: Nabakem SM-15 Surface condition: As casted
Pole spacing: 75-150 mm Batch No.: 220621/7 Cleaned by: Brusher
Lifting power: Background contrast: Nabakem MP-35 Lighting condition: daylight (2000 lux)
4.5 KG Batch No.: 220722/1C Date of inspection: Nov.-2022
Field strength assessment: Burmah Castrol Strip
Result
No. Part ID / Serial no. Tested locations Noted Findings Remark
ACC/REJ
1 MT 121012512 Pin Non-Relevant indication ACC 2PCS
2 MT 121113220 Pin Non-Relevant indication ACC 2PCS
3 BLP-05324-002 Padeye, Welding Non-Relevant indication ACC -
Reference photo:

Remark:
Legends: ACC: Accepted REJ: Rejected IC: Intermittent cold lap
C: Crack U: Undercut LP: Lack of penetration
CP: Clustered Porosity CR: Crater crack P: Porosity
LF: Lack of fusion CL: Cold lap SI: Slag inclusion
Inspector / examiner QA/QC Reviewed by client
Name: PHAM QUOC KIET Name: Name:
Signature: Signature: Signature:

Date: 30/11/2022 Date: Date:


Report No.: BD-M/2212-004
MAGNETIC PARTICLE TESTING REPORT
Page: 1 of 1

Code / Standards: BS-6072-1981 End User: BIEN DONG PETROLEUM OPERATING COMPANY
Test in accordance with: BD-HSE-P- Location: MT1-WHP
0030: Inspection and Certification of Project: 6 MONTH INSPECTION LIFTING GEAR
Lifting Equipment Item: LIFTING GEAR - SHACKLE
Equipment: Yoke MY-2 MPI method Material type: Carbon Steel
Serial No.: 2006011 Visible wet continuous Welding process: N/A
Current: AC MPI ink: Nabakem SM-15 Surface condition: As casted
Pole spacing: 75-150 mm Batch No.: 220621/7 Cleaned by: Brusher
Lifting power: Background contrast: Nabakem MP-35 Lighting condition: daylight (2000 lux)
4.5 KG Batch No.: 220722/1C Date of inspection: Nov.-2022
Field strength assessment: Burmah Castrol Strip
Result
No. Part ID / Serial no. Tested locations Noted Findings Remark
ACC/REJ
1 10-3640MT All surface,Pin Non-Relevant indication ACC -
2 10-3642MT All surface,Pin Non-Relevant indication ACC -
3 10-4352MT All surface,Pin Non-Relevant indication ACC -
4 10-1367MT All surface,Pin Non-Relevant indication ACC -
Reference photo:

Remark:
Legends: ACC: Accepted REJ: Rejected IC: Intermittent cold lap
C: Crack U: Undercut LP: Lack of penetration
CP: Clustered Porosity CR: Crater crack P: Porosity
LF: Lack of fusion CL: Cold lap SI: Slag inclusion
Inspector / examiner QA/QC Reviewed by client
Name: PHAM QUOC KIET Name: Name:
Signature: Signature: Signature:

Date: 30/11/2022 Date: Date:


Report No.: BD-M/2212-005
MAGNETIC PARTICLE TESTING REPORT
Page: 1 of 1

Code / Standards: BS-6072-1981 End User: BIEN DONG PETROLEUM OPERATING COMPANY
Test in accordance with: BD-HSE-P- Location: MT1-WHP
0030: Inspection and Certification of Project: 6 MONTH INSPECTION LIFTING GEAR
Lifting Equipment Item: LIFTING GEAR - SHACKLE
Equipment: Yoke MY-2 MPI method Material type: Carbon Steel
Serial No.: 2006011 Visible wet continuous Welding process: N/A
Current: AC MPI ink: Nabakem SM-15 Surface condition: As casted
Pole spacing: 75-150 mm Batch No.: 220621/7 Cleaned by: Brusher
Lifting power: Background contrast: Nabakem MP-35 Lighting condition: daylight (2000 lux)
4.5 KG Batch No.: 220722/1C Date of inspection: Nov.-2022
Field strength assessment: Burmah Castrol Strip
Result
No. Part ID / Serial no. Tested locations Noted Findings Remark
ACC/REJ
1 H22T-2 All surface Non-Relevant indication ACC -
Reference photo:

Remark:
Legends: ACC: Accepted REJ: Rejected IC: Intermittent cold lap
C: Crack U: Undercut LP: Lack of penetration
CP: Clustered Porosity CR: Crater crack P: Porosity
LF: Lack of fusion CL: Cold lap SI: Slag inclusion
Inspector / examiner QA/QC Reviewed by client
Name: PHAM QUOC KIET Name: Name:
Signature: Signature: Signature:

Date: 30/11/2022 Date: Date:


Report No.: BD-M/2212-006
MAGNETIC PARTICLE TESTING REPORT
Page: 1 of 1

Code / Standards: BS-6072-1981 End User: BIEN DONG PETROLEUM OPERATING COMPANY
Test in accordance with: BD-HSE-P- Location: MT1-WHP
0030: Inspection and Certification of Project: 6 MONTH INSPECTION LIFTING GEAR
Lifting Equipment Item: LIFTING GEAR - SHACKLE
Equipment: Yoke MY-2 MPI method Material type: Carbon Steel
Serial No.: 2006011 Visible wet continuous Welding process: N/A
Current: AC MPI ink: Nabakem SM-15 Surface condition: As casted
Pole spacing: 75-150 mm Batch No.: 220621/7 Cleaned by: Brusher
Lifting power: Background contrast: Nabakem MP-35 Lighting condition: daylight (2000 lux)
4.5 KG Batch No.: 220722/1C Date of inspection: Nov.-2022
Field strength assessment: Burmah Castrol Strip
Result
No. Part ID / Serial no. Tested locations Noted Findings Remark
ACC/REJ
1 582786MT Main Hook, Auxiliary hook Non-Relevant indication ACC -
2 1446309HT Main Hook, Auxiliary hook Non-Relevant indication ACC -
3 PQP 1472122 Main Hook, Auxiliary hook Non-Relevant indication ACC -
Reference photo:

Remark:
Legends: ACC: Accepted REJ: Rejected IC: Intermittent cold lap
C: Crack U: Undercut LP: Lack of penetration
CP: Clustered Porosity CR: Crater crack P: Porosity
LF: Lack of fusion CL: Cold lap SI: Slag inclusion
Inspector / examiner QA/QC Reviewed by client
Name: PHAM QUOC KIET Name: Name:
Signature: Signature: Signature:

Date: 30/11/2022 Date: Date:


Report No.: BD-M/2212-007
MAGNETIC PARTICLE TESTING REPORT
Page: 1 of 1

Code / Standards: BS-6072-1981 End User: BIEN DONG PETROLEUM OPERATING COMPANY
Test in accordance with: BD-HSE-P- Location: MT1-WHP
0030: Inspection and Certification of Project: 6 MONTH INSPECTION LIFTING GEAR
Lifting Equipment Item: LIFTING GEAR - SHACKLE
Equipment: Yoke MY-2 MPI method Material type: Carbon Steel
Serial No.: 2006011 Visible wet continuous Welding process: N/A
Current: AC MPI ink: Nabakem SM-15 Surface condition: As casted
Pole spacing: 75-150 mm Batch No.: 220621/7 Cleaned by: Brusher
Lifting power: Background contrast: Nabakem MP-35 Lighting condition: daylight (2000 lux)
4.5 KG Batch No.: 220722/1C Date of inspection: Nov.-2022
Field strength assessment: Burmah Castrol Strip
Result
No. Part ID / Serial no. Tested locations Noted Findings Remark
ACC/REJ
1 MT 121012512 Pin Non-Relevant indication ACC -
2 MT 121113220 Pin Non-Relevant indication ACC -
Reference photo:

Remark:
Legends: ACC: Accepted REJ: Rejected IC: Intermittent cold lap
C: Crack U: Undercut LP: Lack of penetration
CP: Clustered Porosity CR: Crater crack P: Porosity
LF: Lack of fusion CL: Cold lap SI: Slag inclusion
Inspector / examiner QA/QC Reviewed by client
Name: PHAM QUOC KIET Name: Name:
Signature: Signature: Signature:

Date: 30/11/2022 Date: Date: