3-Color Display Digital Gap Checker New

G type 0.02 to 0.15 mm


Rated detection distance range (Displayable/Settable range: 10 to 300)
H type 0.05 to 0.30 mm
Rated detection distance range (Displayable/Settable range: 30 to 500)
RoHS

Check at a glance if the workpiece is placed or not!


Main screen
ON: Placed Workpiece OFF: Not placed Workpiece

The clearance distance between the detection


surface and the workpiece can be found intuitively!
Sub screen
Switch output/
Screen indication
Large gap
Workpiece
When the workpiece is away
from the detection surface,
the level meter will be away
from the switch point value


Switch point bar.
value bar
Level meter

When the workpiece is seated


on the detection surface, the
level meter will reach the
Workpiece switch point value bar.
Small gap

Detection surface
The number of level meter symbols changes
Detection nozzle depending on the clearance between the work-
Air piece and the detection surface. A clearance
Confirmation of the position which cannot actually be seen can be indi-
of the molding die cated on the display.

Simple Setting
Setting is possible while checking
the displayed value! STEP1 STEP2 STEP3
Snap shot function
Pressing the and buttons for a

3
Placement
status Workpiece
minimum of 1 second will make the switch
point the same as the current displayed value!
steps Clearance gauge Press the Press the
···Features 1
Air button. Press the or buttons button
to set the switch point value. to complete.

Energy Saving ···Features 2 Manifold ···Features 3

• Air consumption: 60% reduction


Environmental Resistance ···Features 1

• Improved drainage resistance: 10 times or more


∗ Compared with the ISA2 based on the SMC’s specific testing condition (oil proof test).
With control unit
• Easier maintenance

Series ISA3
CAT.ES100-105A
Series ISA3

3 Step Setting (Switch Point Change Mode)


A simple operation to enter the switch point value (point Pressing the and buttons for a minimum of 1 second,

at which the clearance reaches the switch point value) Snap shot
function
then releasing the buttons when the displayed switch point value disappears,
will make the switch point the same as the current displayed value.

Switch point
Clearance gauge setting
Placed
Displayed (Switch output ON)
value
Workpiece
Switch
point
value
Switch point value ≥ Displayed value

Not placed
Air (Switch output OFF)

1 Reproduce the seating of the workpiece, 2 Press the or buttons to 3 Press the button to
Switch point value < Displayed value
then press the button. set the switch point value. complete the setting.

Features of the 2-Screen, 3-Color Digital Display


The seating condition can be checked at a glance. The sub screen display can be selected from 6 display options.
Main screen

Workpiece Workpiece

Placed Not placed


(Switch output ON) (Switch output OFF)

Sub screen

Level meter Displayed value SUP side pressure OUT side pressure Switch point value Display OFF

∗ The displayed value is a reference value obtained by converting the distance between the workpiece and the detection surface into a digital numerical value, it is not displayed in units.
For details, refer to “Relationship between Displayed Value and Distance” on page 7.

Improved Environmental Resistance


Easier maintenance Measures against drainage
The internal orifice part can be removed for cleaning. It is not necessary to remove the piping
or metal connection fitting for cleaning when the product is installed in the user’s equipment.
Drainage
resistance: 10 times or more
∗ Based on the SMC’s specific testing condition (oil proof test).
∗ Compared with the ISA2.

Withstand pressure expanded 3 times∗


compared with

600 kPa
Orifice
the ISA2
Max.:
∗ Compared with the ISA2 with 0.2 MPa pressure gauge.

High pressure flushing is possible.


∗ If the orifice is taken out, perform the switch point setting again. ∗ The switch output will be OFF during flushing.

Features 1
3-Color Display Digital Gap Checker

 Noise Energy Measures


reduction saving against clogging

Noise Energy
A Exhaust noise reduction
B Air consumption saving

Zero 60% reduction ∗

The conventional model (ISA2) needs to exhaust The new detection principle eliminates air being
air from the exhaust port due to the bridge circuit. exhausted from the product. This makes the flow
The ISA3 does not exhaust air from the product consumption 0 L/min. when the workpiece is
body. seated.
This reduces noise considerably compared with A much lower air consumption is required than
the conventional model. the conventional model.
∗ Conditions: Unseated for 5 seconds and seated for 20 seconds

Comparison of detection circuit

New ISA3 Existing model (ISA2) A B


EXH port
P1
Sensor Sensor SUP
SUP S1 S3
port
port S2
Sensor
S1
Detection S2 S4
port
P2
Detection
port

D C
S1, S2: Fixed orifice
S1: Fixed orifice
S3: Variable orifice (adjusted by setting handle)
S2: Detection nozzle
S4: Detection nozzle

Measures Measures
C Number of orifices against clogging D Orifice area ratio against clogging
3→1 68% increase
By reducing the number of internal orifices from 3 A larger orifice area provides less possibility of
to 1, there is less possibility of variations in the clogging.
output due to clogging. Even if the orifice is clogged with foreign matter,
By removing the setting handle for S3, variations the product construction enables cleaning with
in the detection distance are prevented. the internal orifice removed.

Features 2
Series ISA3

 Compact & Lightweight  Piping Variations


Volume: 40 % reduction Piping specification:
C type
Weight: 55 % reduction Piping specification:
(Comparison between ISA3-GC and the conventional model ISA2 with One-touch fitting) F type
63
38 45

Rc1/8

G1/8 ∗
One-touch fitting (ø6)
90.6
111.2
G1/8 ∗
∗ Conforming to ISO1179-1

ISA3 Mounting
ISA2 Bracket

Smooth front surface without projections


DIN rail

 Keylock Function Locked


A key LED turns ON when the prod-
uct is locked and the button opera-
tion is disabled to prevent uninten-
tional changes to set values.

 Manifold
With control unit Without control unit

Regulator Solenoid valve (2 port)

∗ Bracket mounting only

Features 3
3-Color Display Digital Gap Checker

 Application Examples

Confirmation of the datum level


for press fitting of a shaft
ON: Placed
Shaft

Datum
level

OFF: Not placed

Datum
level

Confirmation of close contact with Confirmation of close contact with


the datum level for machining the workpiece for machining

 Main Functions
Display OFF mode Security code
Display OFF mode can be se- By activating the security code, Security code:
The numerical Input an arbitrary
lected. The display can be turned value disappears the key lock cannot be released 3-digit value.
OFF to reduce power consump- and only the without entering a security code.
decimal points
tion. blink.

Displayed value compensation


Display color The displayed value can be corrected within ±20% R.D. of the
The color of the main display When ON: Green When OFF: Orange displayed value at the time of shipment.
can be set to change depending
When ON: Orange When OFF: Green
upon the output activity. The
Normally: Orange Forced output
display color change makes vis-
ual identification of the output Normally: Green The output can be fixed to an on/off state when starting the system
ON/OFF easier. or during maintenance. This enables confirmation of the wiring
and prevents system errors due to unexpected output.

Unit conversion
Zero-clear of pressure display
The pressure unit dis- Display unit kPa bar psi
played on the sub screen The pressure value displayed on the sub screen can be cleared to
Minimum setting unit 1 0.01 0.1
can be changed. zero.

Features 4
3-Color Display
Digital Gap Checker

Series ISA3 RoHS

How to Order

ISA3 G C N M 1 B
Rated distance range
Option 2 (Bracket) Control unit
G 0.02 to 0.15 mm
Nil None (DIN rail mounting) ∗2 Nil Without control unit
H 0.05 to 0.30 mm
Without control unit ∗3 ∗4 With control unit ∗5 With control unit ∗5
Piping specifications Regulator ∗6
Symbol Supply side Detection side B AR20-02G-1-A
+
ø6 One-touch fitting Solenoid valve
(2 port type)
C Rc1/8 ∗2: Order DIN rail separately. VX210ZZ2AX276
∗3: At the factory, the options are not
The supply port is available
attached to the product, but packed
together with it for shipment. only on the left side.
∗4: About the number of brackets,
G1/8 ∗1 1 station: 1 piece is packed, L1
2 stations or more: 2 pieces are packed.
F G1/8 ∗1 Option 1 (Cable)
Stations Straight ∗3
1 1 station
∗1: Conforming to ISO1179-1 2 2 stations
3 3 stations Nil
Output specifications 4 4 stations
N NPN output 5 5 stations
P PNP output 6 6 stations
Right angle ∗3 ∗5: Select “B” for Option 2 (Bracket)
Unit specifications of pressure value if the product with control unit is
L to be ordered. The bracket for
Nil With unit conversion function
the control unit is shipped mount-
M Fixed SI unit ed to the product.
Mounting position of the bracket
∗6: When the piping specification is
2 stations n stations N None option C, the supply port for the
(Mount to 1st and 2nd station) (Mount to 1st and nth station) ∗3: At the factory, the regulator is Rc1/4.
options are not attached When the piping specification is
to the product, but option F, the supply port for the
packed together with it regulator is G1/4 (according to
for shipment. ISO16030).

1 2 1 2 … n

Parts List

 Joint screws  Seal for  Bracket


Spacer ∗
(
2 screws,
2 spacers, 2 nuts ) extra station
ISA-15
ISA-14

Stations Part no.


Seal for 2 ISA-16-2
extra station
3 ISA-16-3
ISA-15
4∗ ISA-16-4
5 ISA-16-5
6∗ ISA-16-6
With 3 tapping
screws (3 x 8)

Joint screws (2 pcs.)  Threaded plug with seal



ISA-16- ISA-12-
Threaded plug with seal
ISA-12- Piping Part no.
Rc1/8 ISA-12-A
∗ Spacers are included for 4 and 6 stations. G1/8 ISA-12-C
1
3-Color Display Digital Gap Checker Series ISA3

Parts List
 DIN rail  Cable with connector
ISA-5- ZS-31-B ZS-31-C
Straight 5 m Right angle 5 m

L Stations Part no. L


1 ISA-5-1 73.0
1.25 8 4.5 7.5
2 ISA-5-2 135.5
3 ISA-5-3 173.0
4 ISA-5-4 210.5
5.5
35

35
5 ISA-5-5 248.0
6 ISA-5-6 285.5

Parts List (Control Unit)


 Regulator
AR20 02G-1-A

Piping specifications
Nil Rc1/4
F G1/4 ∗ Refer to the WEB catalog or the
Best Pneumatics No. 5 for details.
∗: Conforming to ISO16030

 Solenoid valve (2 port type)


VX210 Z Z2A X276
Restrictor needle
Specifications
Symbol Specifications
· With restrictor For specifications other than X276,
X276 refer to the WEB catalog or the
· IN, OUT ports: No thread machining
Best Pneumatics No. 7.
Voltage/Electrical entry
Symbol Voltage Electrical entry
DIN terminal with light
Z2A 24 VDC
(With surge voltage suppressor)

Body material/Port size/Orifice diameter


Symbol Body material Port size Orifice diameter
Z Al 1/8 ø4

 Bracket (For with control unit)  Spacer with bracket  Modular adapter
ISA-17 Y200T-A E210-U01

With 2 tapping screws (3 x 8)


2
Series ISA3

Parts Structure
Without control unit
Threaded plug with seal
ISA-12-
Cable with connector
Joint screws
ZS-31-B
ISA-16-

Cable with connector


ZS-31-C Seal for extra station
ISA-15

Bracket
ISA-14

With control unit Threaded plug with seal


ISA-12-
Cable with connector
Joint screws
ZS-31-B
ISA-16-

Cable with connector


ZS-31-C Seal for extra station
ISA-15

Modular adapter
E210-U01

Solenoid valve

Bracket
ISA-17

Spacer with bracket


Y200T-A

Regulator

Caution
SMC products are not intended for use as instruments for legal metrology.
Measurement instruments that SMC manufactures or sells have not been qualified by type approval tests relevant to the metrology (measurement) laws
of each country. Therefore, SMC products cannot be used for business or certification ordained by the metrology (measurement) laws of each country.
3
3-Color Display Digital Gap Checker Series ISA3

For the Common Precautions for the Gap Checker, refer to “Handling Precautions for SMC Products.”
For the Specific Product Precautions, refer to the Operation Manual at SMC website.
Specifications

Model ISA3-G ISA3-H


Applicable fluid Dry air (Filtered through a 5 µm filter)
Rated distance range 0.02 to 0.15 mm 0.05 to 0.30 mm
Displayable/Settable range (Distance reference) ∗1 10 to 300 ∗4 30 to 500 ∗4
Minimum display unit (Distance reference) ∗1 1
Rated pressure range 100 to 200 kPa
Displayable range (Pressure value) ∗2 −20 to 220 kPa
Withstand pressure 600 kPa
Detection nozzle ø1.5 ∗3
Consumption flow rate 12 L/min or less 22 L/min or less
Power supply voltage 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection)
Current consumption 25 mA or less
Switch output 1 output (NPN or PNP)
Maximum load current 10 mA
Maximum applied voltage 26.4 V
Residual voltage 1 V or less (at 10 mA)
Short circuit protection Provided
Repeatability 0.010 mm 0.020 mm
Temperature characteristics (Reference: 25°C) 0.015 mm 0.030 mm
Hysteresis 0 to variable (Default: 20)
2-screen display, LCD
Display Main screen: 3-digit, 7-segment 2-color (Orange/Green)
Sub screen: 6-digit, 7-segment 1-color (White)
Enclosure IP67 equivalent
Operating temperature range Operating: 0 to 50°C, Stored: −20 to 70°C (No condensation or freezing)
Environment Operating humidity range Operating/stored: 35 to 85% RH (No condensation)
Withstand voltage 1000 VAC or more (in 50/60 Hz) for 1 minute between terminals and housing
Insulation resistance 2 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
For piping type F, Supply port: G1/8 (ISO1179-1), Detection port: G1/8 (ISO1179-1)
Piping specifications
For piping type C, Supply port: Rc1/8, Detection port: ø6 One-touch fitting
M12 cable with 4-pin connector, 4 cores, ø4, 5 m
Cable
Conductor O.D.: 0.72 mm, Insulator O.D.: 1.14 mm
Weight 113 g (Cable not included, One-touch fitting)
Standards CE, RoHS compliant
∗1: For details, refer to “Relationship between Displayed Value and Distance” on page 7.
∗2: The pressure value will be indicated on the sub screen.
∗3: For details of the detection nozzle, refer to the figures on page 7.
∗4: If hysteresis is set to 20 (Default setting), “Displayable/Settable range of G type” is limited to 280 and “Displayable/Settable range of H type” is limited to 480.

Rated Detection Distance Range and Displayable/Settable Range

Caution
The displayed value is a reference value obtained by converting the distance between the workpiece and the de-
tection surface into a digital numerical value, it is not displayed in units.
For details, refer to “Relationship between Displayed Value and Distance” on page 7.
Rated detection distance range: Detection distance within which the product meets the specifications.
Displayable/Settable range: It is possible to display or set values, but it is not guaranteed to meet the specifications.

Distance
Model
0.02 mm 0.05 mm 0.15 mm 0.30 mm 0.50 mm

ISA3-G type

ISA3-H type

Rated detection distance range


Displayable/Settable range
4
Series ISA3

Supply Pressure Dependence Characteristics


The detection distance for turning ON the output depends on the supply pressure.
The graphs below show the variation of the distance for the product to turn ON, for 3 types of gap, by changing the supply pressure (±50 kPa)
when the product is set to turn ON at 150 kPa supply pressure.

Test conditions Detection nozzle: ø1.5 Piping: ø6 x ø4 tube Reference pressure: 150 kPa
∗ Use within the rated pressure range (100 kPa to 200 kPa).
It will be impossible to measure the gap when the operating pressure is less than 80 kPa or more than 220 kPa. And the output will be OFF.
(Refer to “Relationship between Supply Pressure and Display” on page 10.)

ISA3-G ISA3-H
Piping length: 1 m Piping length: 1 m

0.30 Reference pressure 0.60 Reference pressure


0.25 mm 0.5 mm
The distance of switch ON [mm]

The distance of switch ON [mm]


0.25 0.50

0.20 0.40
0.15 mm 0.3 mm
0.15 0.30

0.10 0.20

0.05 0.10 0.05 mm


0.02 mm
0 0
75 100 125 150 175 200 225 75 100 125 150 175 200 225
Supply pressure [kPa] Supply pressure [kPa]

Piping length: 3 m Piping length: 3 m

0.30 Reference pressure 0.60 Reference pressure


0.25 mm
The distance of switch ON [mm]

The distance of switch ON [mm]

0.5 mm
0.25 0.50

0.20 0.40
0.15 mm 0.3 mm
0.15 0.30

0.10 0.20

0.05 0.10 0.05 mm


0.02 mm
0 0
75 100 125 150 175 200 225 75 100 125 150 175 200 225
Supply pressure [kPa] Supply pressure [kPa]

Piping length: 5 m Piping length: 5 m

0.30 Reference pressure 0.60 Reference pressure


0.25 mm
The distance of switch ON [mm]

The distance of switch ON [mm]

0.5 mm
0.25 0.50

0.20 0.40
0.15 mm 0.3 mm
0.15 0.30

0.10 0.20

0.05 0.10 0.05 mm


0.02 mm

0 0
75 100 125 150 175 200 225 75 100 125 150 175 200 225
Supply pressure [kPa] Supply pressure [kPa]

5
3-Color Display Digital Gap Checker Series ISA3

Response Time
Response time is the elapsed time between the pressure supply and the turning ON of the switch output.
The response time varies depending on the piping length from the OUT port to the detection nozzle, and the seating condition of the workpiece.
The graphs below show the response time when the workpiece is approached at 90% distance and 0% distance (close contact). (∗: The switch
point is 100% distance.)
(Example: When the switch point is set to 0.1 mm, the response time when the workpiece is at 0.09 mm and 0 mm are measured.)

Test conditions Detection nozzle: ø1.5 Piping: ø6 x ø4 tube Reference pressure: 200 kPa

ISA3-G ISA3-H
Piping length: 1 m Piping length: 1 m

2.0 2.0
Response time when the Response time when the
workpiece is set at 90% workpiece is set at 90%
distance
Response time [sec]

1.5 distance

Response time [sec]


1.5
Response time for close Response time for close
contact of workpiece contact of workpiece
1.0 1.0

0.5 0.5

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0 0.1 0.2 0.3 0.4 0.5
Distance [mm] Distance [mm]

Piping length: 3 m Piping length: 3 m

2.0 2.0
Response time when the Response time when the
workpiece is set at 90% workpiece is set at 90%
distance distance
Response time [sec]

Response time [sec]

1.5 1.5
Response time for close Response time for close
contact of workpiece contact of workpiece
1.0 1.0

0.5 0.5

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0 0.1 0.2 0.3 0.4 0.5
Distance [mm] Distance [mm]

Piping length: 5 m Piping length: 5 m

2.0 2.0
Response time when Response time when the
the workpiece is set workpiece is set at 90%
at 90% distance distance
Response time [sec]

Response time [sec]

1.5 1.5
Response time for Response time for close
close contact of contact of workpiece
1.0 workpiece 1.0

0.5 0.5

0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0 0.1 0.2 0.3 0.4 0.5
Distance [mm] Distance [mm]

6
Series ISA3

Relationship between Displayed Value and Distance


The graphs below show the relationship between the displayed value and distance.

ISA3-G ISA3-H
Detection nozzle: ø1.5 Supply pressure: 200 kPa Detection nozzle: ø1.5 Supply pressure: 200 kPa
Detection piping: ø6 x ø4 tube 1 m, 3 m, 5 m Detection piping: ø6 x ø4 tube 1 m, 3 m, 5 m
300 500
450
250 3m
1m 400
1m
5m 350
200
Displayed value

Displayed value
3m 300
5m
150 250
200
100
150

50 100
50
0 0
0 0.05 0.1 0.15 0.2 0.25 0.3 0 0.1 0.2 0.3 0.4 0.5
Actual distance [mm] Actual distance [mm]

Nozzle Shape
The nozzle shape must be similar to Figure 1.
Do not chamfer the nozzle as shown in Figure 2, as the characteristics will be affected.

Fig.1: Recommended nozzle shape Fig.2: Unsuitable nozzle shape

ø1.5
2 or more

ø3 or more

7
3-Color Display Digital Gap Checker Series ISA3

Dimensions
ISA3- (Bracket mounting)

5000
1 3
5000
1.8 L1

38.5
38

30.8
4
77
66
25.6

Pin no. Description Lead wire color


17
H

1 DC (+) Brown
11
5.5

18 6.5 2 N.C. White


24 3 DC (–) Blue
Supply port
36 Detection port
ISA3-C: Rc1/8 4 OUT1 Black
ISA3-F: G1/8 ∗ ISA3-C: ø6 One-touch fitting
ISA3-F: G1/8 ∗
Stations 1 2 3 4 5 6
∗: Conforming to L1 38 76 114 152 190 228
47

ISO1179-1
Piping type C (One-touch fitting) F (G thread)
18

H 13.6 19
2

ISA3- (DIN rail mounting)

2
5000

1 3
5000
1.8 L1
38.5

38
30.8

4
77
66
(30.8)
25.6

Pin no. Description Lead wire color


H

1 DC (+) Brown
18 5.25 L2 2 N.C. White

Supply port
L3 3 DC (–) Blue
ISA3-C: Rc1/8 4 OUT1 Black
ISA3-F: G1/8 ∗
Stations 1 2 3 4 5 6
L1 38 76 114 152 190 228
47

∗: Conforming to L2 62.5 125 162.5 200 237.5 275


18

ISO1179-1 L3 73 135.5 173 210.5 248 285.5


Detection port
(3.7)

ISA3-C: ø6 One-touch fitting


Piping type C (One-touch fitting) F (G thread)
ISA3-F: G1/8 ∗ H 13.6 19

8
Series ISA3

Dimensions
ISA3--B-L1 (With control unit)

30 58.5 41.6 46.2 L1 57


3.5 12 1.6

11
5.5

40.4
29
24

66

16
24

3.1
33

52.5
67.4

13.6
38
Supply port L2 13 30
ISA3-C: Rc1/4
ISA3-F: G1/4 ∗1 Detection port
ISA3-C: ø6 One-touch fitting
∗: Bracket mounting only ISA3-F: G1/8 ∗2
Stations 1 2 3 4 5 6
∗1: Conforming to ISO16030
L1 55.6 93.6 131.6 169.6 207.6 245.6
∗2: Conforming to ISO1179-1
L2 136.4 174.4 212.4 250.4 288.4 326.4

ZS-31-B (Cable with connector)


5000 38.5 2
Brown 1
White
ø15

Blue
Black 3
4

ZS-31-C (Cable with connector) Connector pin no.


Brown 5000 23.5
White
Blue Pin no. Lead wire color Description
Black 1
30.8

Brown DC (+)
2 White N.C.
3 Blue DC (–)
ø15 4 Black OUT1

ISA-14 (Bracket for without control unit) Y200T-A (Spacer with bracket)
36 53.4
15.5
18.6

28 6 30
4

3.5
5.5
51.5
9.6

4
3.

29
24
x
3

67
5.5
24
5.5

33
6

5.5

6.5 1.6
24 12

ISA-17 (Bracket for with control unit)


28
16 16
5.5 (1.6)
6
12

22
6.5

4
3.
4

x 19.2
2
A 9
3-Color Display Digital Gap Checker Series ISA3

Error Indication

Main screen Name Description Measures

Displayed when supply pressure is not in the Supply rated pressure (100 kPa to 200 kPa).
Supply pressure error range 80 kPa to 220 kPa. Measurement is not The product will return to measurement
possible. mode automatically.

Outside of the displayable


Move the workpiece closer to the detec-
range The workpiece is outside the displayable range.
tion nozzle.
(Switch point change mode)

Turn the power OFF and remove the


The switch output (OUT1) load current has ex-
OUT1 over current error cause of the over current. Then turn the
ceeded 80 mA.
power ON again.

Zero clear was not performed at atmospheric


Perform zero clear at atmospheric pres-
Zero clear error pressure. (Pressure outside of ±14 kPa was
sure.
supplied present.)

Turn the power OFF and turn it ON


System error An internal data error has occurred.
again.

to

Sub screen Name Description Measures

Supply pressure error Pressure exceeding 220 kPa is supplied.


(When [SUP side pressure Keep the supply pressure within the dis-
value display] is set to the playable range of –20 kPa to 220 kPa.
sub screen) Vacuum pressure (less than –20 kPa) is sup-
plied.

Relationship between Supply Pressure and Display

Detection which satisfies


Cannot be detected. the specification is available. Cannot be detected.

Rated pressure range

Can be detected, but Can be detected, but Breakage


specification is not satisfied. specification is not satisfied. may occur.

Main screen
[ ] Range in which [ON/OFF] is displayed in the main screen [ ]

Switch output is automatically turned OFF. Switch output is normally output. Switch output is automatically turned OFF.

Sub screen
[ ] Range which can be displayed when [SUP side pressure value display] is set to the sub screen [ ]

−20 80 100 200 220 600


(Withstand pressure)
Pressure [kPa]

10
These safety instructions are intended to prevent hazardous situations and/or
Safety Instructions equipment damage. These instructions indicate the level of potential hazard with
the labels of “Caution,” “Warning” or “Danger.” They are all important notes for
safety and must be followed in addition to International Standards (ISO/IEC)∗1),
and other safety regulations.
∗1) ISO 4414: Pneumatic fluid power – General rules relating to systems.
Caution indicates a hazard with a low level of risk ISO 4413: Hydraulic fluid power – General rules relating to systems.
Caution: which, if not avoided, could result in minor or IEC 60204-1: Safety of machinery – Electrical equipment of machines.
moderate injury.
(Part 1: General requirements)
Warning indicates a hazard with a medium level of ISO 10218-1: Manipulating industrial robots – Safety.
Warning: risk which, if not avoided, could result in death or etc.
serious injury.
Danger indicates a hazard with a high level of risk
Danger : which, if not avoided, will result in death or serious
injury.

Warning Caution
1. The compatibility of the product is the responsibility of the 1. The product is provided for use in manufacturing industries.
person who designs the equipment or decides its specifications. The product herein described is basically provided for peaceful use in
Since the product specified here is used under various operating conditions, its manufacturing industries.
compatibility with specific equipment must be decided by the person who designs If considering using the product in other industries, consult SMC beforehand and
the equipment or decides its specifications based on necessary analysis and test
exchange specifications or a contract if necessary.
results. The expected performance and safety assurance of the equipment will be
If anything is unclear, contact your nearest sales branch.
the responsibility of the person who has determined its compatibility with the
product. This person should also continuously review all specifications of the
product referring to its latest catalog information, with a view to giving due
consideration to any possibility of equipment failure when configuring the Limited warranty and Disclaimer/
equipment.
2. Only personnel with appropriate training should operate
Compliance Requirements
machinery and equipment. The product used is subject to the following “Limited warranty and Disclaimer”
The product specified here may become unsafe if handled incorrectly. The and “Compliance Requirements”.
assembly, operation and maintenance of machines or equipment including our Read and accept them before using the product.
products must be performed by an operator who is appropriately trained and
experienced. Limited warranty and Disclaimer
3. Do not service or attempt to remove product and machinery/
equipment until safety is confirmed. 1. The warranty period of the product is 1 year in service or 1.5 years after
1. The inspection and maintenance of machinery/equipment should only be the product is delivered, whichever is first.∗2)
performed after measures to prevent falling or runaway of the driven objects Also, the product may have specified durability, running distance or
have been confirmed. replacement parts. Please consult your nearest sales branch.
2. When the product is to be removed, confirm that the safety measures as
mentioned above are implemented and the power from any appropriate source 2. For any failure or damage reported within the warranty period which is clearly our
is cut, and read and understand the specific product precautions of all relevant responsibility, a replacement product or necessary parts will be provided.
products carefully. This limited warranty applies only to our product independently, and not to any
3. Before machinery/equipment is restarted, take measures to prevent other damage incurred due to the failure of the product.
unexpected operation and malfunction.
4. Contact SMC beforehand and take special consideration of safety 3. Prior to using SMC products, please read and understand the warranty terms
measures if the product is to be used in any of the following and disclaimers noted in the specified catalog for the particular products.
conditions. ∗2) Vacuum pads are excluded from this 1 year warranty.
1. Conditions and environments outside of the given specifications, or use A vacuum pad is a consumable part, so it is warranted for a year after it is delivered.
Also, even within the warranty period, the wear of a product due to the use of the vacuum pad
outdoors or in a place exposed to direct sunlight.
or failure due to the deterioration of rubber material are not covered by the limited warranty.
2. Installation on equipment in conjunction with atomic energy, railways, air
navigation, space, shipping, vehicles, military, medical treatment, combustion
and recreation, or equipment in contact with food and beverages, emergency Compliance Requirements
stop circuits, clutch and brake circuits in press applications, safety equipment
or other applications unsuitable for the standard specifications described in the 1. The use of SMC products with production equipment for the manufacture of
product catalog. weapons of mass destruction (WMD) or any other weapon is strictly prohibited.
3. An application which could have negative effects on people, property, or
animals requiring special safety analysis. 2. The exports of SMC products or technology from one country to another are
4. Use in an interlock circuit, which requires the provision of double interlock for governed by the relevant security laws and regulations of the countries involved
possible failure by using a mechanical protective function, and periodical in the transaction. Prior to the shipment of a SMC product to another country,
checks to confirm proper operation. assure that all local rules governing that export are known and followed.

Safety Instructions Be sure to read “Handling Precautions for SMC Products” (M-E03-3) before using.