Acoustic, digital
current meter OTT ADC
1. Discharge Measuring 1 Setting parameters for discharge 1. Delete Deleting saved file.
1.Settings measuring. 1:Iller1 10:25 18/05
2.Name:*** 2 Enter file name. 2:Iller2 13:37 18/05
3.Party: 3:Iller3 09:12 21/05
4.Notes 3 Enter name for party. 4:Durach1 14:06 24/05
5.START 4 Enter notes. 5:Durach2 10:24 25/05
5 Start measurement.
3. Data Files Call information on saved file. 3. System Menu 1 Enter hours, minutes, seconds
1:Iller1 10:25 18/05 1.Date and Time and year (2-digit).
2:Iller2 13:37 18/05 2.Display 2 Set display and frequency
3:Iller3 09:12 21/05 3.Sound level
4:Durach1 14:06 24/05
of the measured value display.
5:Durach2 10:24 25/05 3 Set volume.
Discharge Measuring Press key 2 and enter file name (max. 8 characters, no spaces or special symbols).
1.Settings Press key 3 and enter party.
2.Name:ILLER5
3.Party:SB&FR Press key 4 and add notes if wanted.
4.Notes Press key 1 ➝ Discharge menu [1/3] opens.
5.START
2a: There are not yet any basic settings at the station
Press key 2, 3, 4 or 5 and Press key 1 and select the Press key 1 and change
set the respective parameters measure method. the measuring time if necessary.
(see below). Press key 2 and select the Press key 2 and change
Press ■ key type of evaluation. the salinity if necessary.
➝ next menu level. Press ■ key
Press key ➝ next menu level.
1 Load... Press key 1 or 2. Select File Select file with its basic settings.
1.Load settings only 1:IllER1 08:24 03/03
2.Continue a 2:ILLER2 14:10 10/04
If point 1 in the Load… menu has been selected:
previous 3:ROTTACH 10:45 11/04 Press key ➝ return to Discharge Measuring menu.
Strem width:10.00 2 Points
Verticals :11 Using MID-section
Measure points:22 Averaging: 30S
2.Water Depth:1.20 3.Gauge :2.48 3.Width :0.50
3.2 Points 4.Define Obstruction If required, call verticals information:
4.End this Vertical Press key.
Enter level if required: press key 3.
Enter parameters for obstruction if necessary:
press key 4.
11:01:56 Position sensor at preset depth (in example 0.96 ). Continue: Press key.
0.96 The symbol for the preset depth (set submersion depth)
m/s
0.85 1.14m
blinks until the sensor position is correct.
Starting measurement: Press key.
1.00
0.96 the set time interval. 1.00 m 0.96 m Continue with measure point 2 as described above.
m/s
0.81 0.96m
V 0.12 m/s
SNR 40 dB
15.5 o C
10.0 V or
1.00
Reject measurement: Press key.
Repeat measurement.
MEASUREMENT
COMPLETED. 3.Streamwidth:10.00
Discharge Measurement Display additional information: Iller5 Display details for the individual
Name: ILLER5 press key 1. Discharge : 0.110 verticals: Press key.
Discharge: 0.110 Avg. Velocity : 0.830
1.Details
End measurement: Avg. Depth : 1.550
2.End Press key 2 and confirm the Area : 6.240
3.Continue query with key in the
subsequent window.
Maintenance Work
Before packing the devices, remove any dirt and dry the probe
and rods with a cloth.
Sensor connection
USB connection
OTT Heres adjuster
On-off switch
Handheld unit
Sensor
connection
line
Sensor
Rod (Ø 20 mm)
OTT Hydromet GmbH
Ludwigstrasse 16
87437 Kempten · Germany
Tel. +49 8 31 56 17- 0
Fax +49 8 31 56 17- 2 09
Document number 10.500.001.K.E 03-0411 info@ott.com · www.ott.com