You are on page 1of 12

Airspan Products

GENERIC
Power Over Ethernet (PoE)
Power Supply Unit (PSU)
Stuart Harfield
sharfield@airspan.com
Airspan Networks
UK

(Mod-150)

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 1
DISCLAIMER STATEMENT

All information provided herein including, but not limited to, Feature Content, Feature Releases, Feature Functionality, Estimated
Dates and Time lines, has been prepared by Airspan Network for general informational and training purposes only and is subject to
change at any time, including, without limitation, as a result of specific field conditions. Airspan Networks is under no obligation
and is making no commitments with regards to any of the information contained herein.
The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned
technologies or hardware or software products are given “as is”.
However, and although there is no guarantee in this regard, Airspan Networks has made all reasonable efforts to ensure that the
information contained in the document is adequate and free of material errors and omissions.
All activities related to the products detailed herein, including, without limitation, the installation, usage and operation of the
products, should be executed by specifically trained and licensed personnel, and be performed in accordance with applicable laws
and standards.
SUBJECT TO APPLICABLE LAW, IN NO EVENT WILL AIRSPAN NETWORKS BE LIABLE FOR ERRORS IN THIS
DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL
OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS
INTERRUPTION, BUSINESS OPPORTUNITY OR DATA, THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE
INFORMATION IN IT.

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 2
Grounding & Surge Protection

PoE Power Over Ethernet


PSU Power Supply Unit

Overview
 PoE/PSU
 AC
 DC

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 3
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Power Supply Unit


Power Over Ethernet
(PSU/PoE)

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 4
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Power Supply Unit/Power Over Ethernet (PSU/PoE)


PSU & PoE Overview
• Power over Ethernet or PoE describes any of several standard or ad-hoc systems which pass electric power along with data on
twisted pair Ethernet cabling
• This allows a single cable to provide both data connection and electric power to devices such as wireless access points, IP
cameras, and VoIP phones
• There are several common techniques for transmitting power over Ethernet cabling
• Two of them have been standardized by IEEE 802.3 since 2003
• These standards are known as Alternative A and Alternative B
A. 10BASE-T
B. 100BASE-TX
• Only two of the four signal pairs in typical Cat 5 (Ethernet )cable are used
• Alternative B separates the data and the power conductors, making troubleshooting easier
• It also makes full use of all four twisted pairs in a typical Cat 5 (Ethernet) cable
• The positive voltage runs along pins 4 and 5, and the negative along pins 7 and 8

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 5
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Power Supply Unit/Power Over Ethernet (PSU/PoE)


PSU & PoE Overview
• Alternative A transports power on the same wires as data for 10 and 100 Mbit/s Ethernet variants
• This is similar to the phantom power technique commonly used for powering condenser microphones
• Power is transmitted on the data conductors by applying a common voltage to each pair
• Because twisted-pair Ethernet uses differential signaling, this does not interfere with data transmission
• The common-mode voltage is easily extracted using the centre tap of the standard Ethernet pulse transformer
• Gigabit Ethernet and faster, all four pairs are used for data transmission, so BOTH Alternatives A and B transport power on wire
pairs also used for data
• In addition to standardizing existing practice for spare-pair (Alternative B) and common-mode data pair power (Alternative A)
transmission, the IEEE PoE standards provide for signalling between the power sourcing equipment (PSE) and powered device (PD)
• This signalling allows the presence of a conformant device to be detected by the power source, and allows the device and source to
negotiate the amount of power required or available

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 6
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Power Supply Unit/Power Over Ethernet (PSU/PoE)


Airspan PSU & PoE Overview
• PoE supplies and provide the required output voltage for the equipment to operate (24V volt)
• The power source for the PoE supply is designed for a specific application. (AC mains input or DC input)
• For mains input most modern switch mode converters are designed to work over a full range of input voltages from around 100V to
264V this allows them to be used in countries with 110V 60Hz mains or countries with 230V 50Hz (including the anticipated voltage
variations)
• For the DC conversion a similar range of input voltages can be accommodated and typically they can be designed for 12V
(automobile applications), 24V (typical USA exchange voltage) or 48V (typical European exchange voltage)
• Specific case of the iB440 DC PoE supply the nominal input voltage is defined as 48V and the 36v – 72V input range is the
maximum range of input voltage variation that can be accommodated while still maintaining the correct output voltage.
• Input voltages outside of these extremes will result in output shutdown due to input over-voltage (at the high end) or input over-
current (at the lowest voltage)
• Note: These systems are often defined by the lead acid battery formats used for emergency back up.

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 7
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Power Supply Unit/Power Over Ethernet (PSU/PoE)


Airspan Products PSU & PoE
• Products powered by Airspan PSU/PoE
• Products based on a 24V PSU/PoE
• AC/Internal/Indoor 3 Pin Power Lead
• DC/External/Outdoor Hard Wire Terminal Block
• They accept data-in via a Shielded RJ45 Input Jack Ethernet Connector
• Providing data and power on the Shielded RJ45 Output Jack Ethernet Connector
• They work by supplying power to the remote device on the 24v Unused Ethernet Pins
• Voltage ranges quoted are the input conditions for the nominal 48V going into the PSU/ PoE supply that provides the 24V via PoE
to the Radio or Antenna Transport Solution
• Ethernet Wires & RJ45 Connector Pins are used for power and data:-
• 1-3 & 2-6 (Data)
• 4-5 (Power)
• 7-8 (Earth)

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 8
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Power Supply Unit/Power Over Ethernet (PSU/PoE) • PSU/PoE have been designed for
PSU & PoE Interfaces - DC/External/Outdoor Installation Internal/Indoor or External/Outdoor use

• 2 Ethernet RJ45 Shielded Female Receptacles- Ports In & Out • DC/External/Outdoor use to be housed or
mounted inside a weatherproof enclosure
• External Power Termination Block/Point
• DC/External/Outdoor type has a hardwire
terminal block, not a three pin connector
receptacle point

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 9
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Power Supply Unit/Power Over Ethernet (PSU/PoE)


PSU & PoE Interfaces - AC/Internal/Indoor Installation • PSU/PoE have been designed for
Internal/Indoor or External/Outdoor use
• 2 Ethernet RJ45 Shielded Female Receptacles- Ports In & Out
• The key feature of the Internal/Indoor
• AC/External Power Lead 3 Pin Receptacle Cable Socket PSU/PoE is that it has a 3 Pin Receptacle
Cable Plug Power Lead connection point

© Airspan Networks Stuart HARFIELD (Global Training Manager), Section 07 - – Generic – PoE – Power Over Ethernet - mod-150 Version:18-12-11 10
Grounding & Surge Protection
Ethernet Ethernet
+ +
. Ethernet PoE PoE Ethernet

PoE PoE Network


UE eNB power Surge 802.11ac Surge power
AC/DC protector protector AC/DC

Installation Power Supply Unit/Power Over Ethernet (PSU/PoE) Weatherproof Enclosure


PSU & PoE Interfaces – Weatherproof Enclosure

• Weatherproof Enclosure
• Ground Wire Ground Point
• Power Cable Terminated to the Hard Point Wiring Terminal Block
• Dc/External/Outdoor PSU/PoE mounted inside the Weatherproof
Enclosure
• PoE Green LED
• RJ45 Connection Female/Male Ethernet Receptacles/Ports
• External Weatherproof Glands(ip67)
• Ground Cable Weatherproof Box
• Ethernet Surge Protection can be installed in this enclosure
(Data In & Data Out Ethernet Cables - Not Shown)