You are on page 1of 1

GENERAL NOTES

2 3 1 4 5 1 6 7 8 8 This drawing is protected under the


copyright Act andcannot be reproduced
in part or in whole wholewithout author
consent
All dimensions are to be checked on site
44 610
written dimensions rules overscaled
8 510 8 650 6 680 5 200 5 100 3 110 5 090 2 270 dimensions

8 310 200 8 550 200 950 900 220 1 180 200 1 200 3 610 200 1 200 3 640 200 1 200 3 840 150 2 300 250 2 340 Any discrepancy in the dimensions is to
800 640 100 300
2 000 2 000
8 500 1 140 5 930 1 960 500 500 1000 500 500 1 250 600 5 190 470 330 400 2 950 2 400 150 2 550 2 340
be reported to the Architect before work
commences

pv
All dimensions are in MM unless
pv
A A unless specified
300

200

200
1 930
1930

2 210
+
_ 5700 All construction Work is to comply with
W 03 W 03 W 03 W 03 W 03 W 03

3 640
pv
3 470 the latest K .B .S standard codes of
B pv pv pv pv pv pv B

4 350
pv pv pv
practice,local authority by -laws and
200

+
_ 5700

1 200

1 200
1 320 6 940 1 750 1 560
NON-SLIP 3 030 2 680 fire regulations
C 1 110 NON-SLIP NON-SLIP C
NON-SLIP CERAMIC TILES BOUTIQUE SHOP This drawing is to be read in conjuction

8 360
+
_ 5700 GENTS CERAMIC TILES CERAMIC TILES +
_ 5700
LADIESCERAMIC TILES

7 650
DOWN

4 800

1 990
with specifications and all other
W 06

WASHROOM WASHROOM +
_ 5700
PHARMACY

5 800
3 890 3 900
NON-SLIP 3 570 FOOT WEAR relevant drawings

6 510
2 500
CERAMIC TILES 3 900 5 850
5700

5 360
+
_ 5 735
3 570 +
_ 5700
NON-SLIP P.V denotes permanent ventilation and

3 530
FRUITSHOP NON-SLIP

3 460
1 740

1 740
LOBBY LOBBY CERAMIC TILES
8 330

pv

9 750

9 670
pv
NON-SLIP
CERAMIC TILES NON-SLIP must be provided above allwindows
D-02
CERAMIC TILES

UP
D-02
CERAMIC TILES and doors where indicated or shown.

7 850
2 350 D-02 6 320

D-11
SUPA MARKET WITH BAKERY

200
D-11
Water meter to be 300mm above ground
12 880

4 875 +
_ 5700 +
_ 5700
+
_ 5700
NON-SLIP
level .
8 870 NON-SLIP 6 000
CERAMIC TILES NON-SLIP CERAMIC TILES All walls under200mm thick to reinforced

2 610
2 325
NON-SLIP NON-SLIP CERAMIC TILES

3 880
CERAMIC TILES CERAMIC TILES with hoop iron after everyalternating
200

D D course
D-02
1 210
6 500

200
Damp proof course to be

2 525
STALLS SPACE
W 07
840

LOBBY
+
_ 5700 NON-SLIP provided under all external walls at grade
D-02 CERAMIC TILES pv
25 050

25 050
D .P .C to be a minimum of 1 5 0mm

3 825
NON-SLIP

4 480
24 750

NON-SLIP

4 140
D-10
3 160
2700

CERAMIC TILES CERAMIC TILES


+
_ 5700 +
_ 5700 above ground level
ACCESORIES
Depth of foundation is tobe determined

2 800
+
_ 5700 DUCTS SPACE 100 2 450 100 2 450 100 2 450 100
E E on site to S.E approval.
1 200

1 400
pv

D-04
All vegetable soil to be removed from

100

200
1 290
1 425 +
_ 5700 under slab and all paved surfaces

FIRE ESCAPE CHUTES

FIRE ESCAPE CHUTES


UP UP

1 540
500

All soils under slab and around external

ROOM

ROOM

2 850
+
_ 5700
LOBBY
+
_ 5700 foundation to be treated for termite
NON-SLIP BOUTIQUE SHOP
1 210

CERAMIC TILES
100 2 450 100 2 450 100 2 450 100
control.

3 565

14 380
7 700

1 540
STALLS SPACE All reinforcement work to
6 590 1 520

DOWN
8 280

F F
490

Structural Engineers details.

2 420
LOBBY Drain pipes passing under tarmac
DOWN

NON-SLIP

10 050
D-04

11 810
driveways and buildings to be encased in
W 06

CERAMIC TILES
1 100

+
_ 5700

110
8 680
1 5 0mm thick concrete surround
NON-SLIP +
_ 5700 pv
NON-SLIP
+
_ 5700
CERAMIC TILES
BEAUTY SHOP All sanitary works to the satisfaction of
+
_ 5700 NON-SLIP CERAMIC TILES

W 07
pv CERAMIC TILES the mechanical engineer
5 750

5 150
5 690
+
_ 5700
+
_ 5700
3 160
2 700

D-10

100 2 450 100 2 450 100 All roads ,storm water drainage and foul
STALLS SPACE STALLS SPACE
sewerage to civil engineers drawings
10 750
D- 14

D- 14
All electrical works to the entire
900

G pv G
W 07

pv pv pv pv pv pv pv

300
satisfaction of the Electrical engineer
780

17 330 8 410 16 200 REV DATE DESCRIPTION BY

300 9 185 300 3 325 100 2 090 100 2090 100 18 .963 200 5 365 375

300 9 185 300 3 560 170 2 520 170 3 170 170 2 710 170 4 440 100 2 090 100 2 090 100 2 090 100 4 340 200 5 560 200

44 610

2 3 1 4 5 1 6 7 8 8

GROUND FLOOR - SCALE 1 : 100

BUILT UP AREAS

Ground Floor
First floor
2nd,3rd,4th,5th,6th,7th
8th,9th,10th,11th,12th
Roof plan

Total

floor
FINISHES SCHEDULE
ceiling
finish

walls skirting

1. Specified floor finish on 1:3 mix cement sand


floor screed not less than 20mm level or
to fall as necessary.
2. 50mm thick 600x600mm precast concrete
paving slabs laid on and incluiding 50mm sand
bed and pointed in cement and sand
paved walkways.
3. 3 coats of approved plastic emulsion paint to
13mm 1:2:3 cement sand lime mix plastered
surfaces of internal wall/ceiling surface.
4. fair face finish to machine cut external walls
with cement sand (1:3) mix mortar pointing
forming half round recessed joints.
5. Heavy duty concrete block road finish
to engineer's specifications.

PAPERSIZE

A0
N

Architect :
Reg .No. :
Signature

Client:
Kachok - Kisumu City - KisumuCounty
Project :
Production drawings
Plot No. Road - Kisumu - Busia
Location: Kachok Town:Kisumu
Architect : Omar Kassim
Scale:
Drawing Title: As shown
Drawing No: Project No: Rev. No:

Drawn By: Checked By: Date:


Omar Kassim
Oketch Spencer

ARCHITECTURAL DESIGN & DRAWING


MIXED USE
URBAN
DEVELOPEMENT

GSPublisherVersion 0.11.100.100

You might also like