You are on page 1of 1

metric composition or saturation temperature as they CHIMNEY - A vertical shaft enclosing one or more

evaporate or condense at constant pressure. flues for conveying flue gases to the outside atmo-
sphere.
204.0 -B-
Factory Built Chimney - A listed chimney.
BOILER, HIGH PRESSURE - A boiler furnishing
steam at pressures in excess of fifteen (15) pounds Masonry Chimney - A chimney of solid
per square inch (103.4 kPa) or hot water at tempera- masonry units, bricks, stones, tisted masonry
tures in excess of 250F (121t) or at pressures in
units, or reinforced concrete, lined with suitable
excess of one hundred and sixty (160) pounds per flue liners.
square inch (1,103.2 kPa).
Metal Chimney - A chimney constructed of
BOILER ROOM - Any room containing a steam or a minimum thickngss not less than
metal with
hot water boiler.
one hundred and twenty-seven one hundredths
(0.127) inch (3.23 mm) (No. 10 manufacturer,s
BONDING JUMPER - A retiabte conductor to standard gauge steel sheet).
ensure the required electrical conductivity between
metal parts required to be electrically connected. CHIMNEY CLASSIFICATIONS:
BREATHING ZONE - The region within an occupied Ghimney, Residential Appliance Type -A
space between three (3) planes anQ seventy-two
factory built or masonry chimney suitable for
(72) inches (1,800 mm) above the floor and more
removing products of combustion from
than (2) two feet (600 mm) from the walls or fixed air-
conditioning equipment.
residential type appliances producing
combustion gases not in excess of 1,000F
(538C), measured at the appliance flue ouflet.
BREATHING ZONE OUTDOOR AIRFLOW (Vbz)
-
The rate of outdoor airflow required in the breathing
Factory built Type HT chimneys have high
temperature thermal shock resistance.
zone of an occupiable space.

BREECHING - A metal connector for medium and


Chimney, Low Heat Appliance Type -A
factory built, masonry, or metal chimney suitable
high heat appliances.
for removing the products of combustion from
BTU/H - The listed maximum capacity of any appli-
fuel burning low heat appliances producing
combustion gases not in excess of 1,000F
ance, absorption unit, 6i burner expressed in British
(538C) under normal operating conditions, but
thermal units input per hour, unless otherwise noted.
capable of producing combustion gases of
1,400F (760C) during intermittent forced firing
BUILDING CODE - The Nationat Buitding Code of the
Philippines that is adopted by this jurisdiction.
for periods up to one hour. All temperatures are
measured at the appliance flue ouflet.
BUILDING OFFtCtALi - See Authority Having
Jurisdiction. Chimney, Medium Heat Appliance Type -A
factory built, masonry, or metal chimney suitable
205.0 for removing the products of combustion from
-c- fuel burning medium heat appliances producing
combustion gases not in excess of 2,000f
CAS NUMBER - The Chemicat Abstract System (1,093C), measured at the appliance flue ouflet.
registry number.

CENTRAL HEATING PLANT oT HEATING PLANT


Ghimney, High Heat Apptiance Type -A
factory built, masonry, or metal chimneysuitable
Environmental heating equipment installed in a
manner to supply heat by means of ducts or pipes to
for removing the products of combustion from
areas other than the room or space in which the
fuel burning high heat appliances producing
equipment is located.
combustion gases in excess of
2,000F(1,093C), measured at the apptiance
flue outlet.
CERTIFIED - A formally stated recognition and
approva! of an acceptable level of competency,
CHIMNEY CONNECTOR - The pipe that connects a
acceptable to the Authority Having fuel burning appliance to a chimney.
Jurisdiction.
CLOSED COMBUSTION SOLTDFUELBURNING
APPLIANCE - A heat producing appliance that
employs a combustion chamber that has no

18 2012 PHILIPPINE MECHANICAL ENGINEERING CODE