SCHEDULE OF RATES 2016-17

PW, P & IWTD, SOUTH ZONE, BANGALORE


SL NO Name Unit Basic Rate

1.0 MORTAR
1.1 KSRB 0.5-1.1 : Providing cement mortar of mix 1:1 (1 cement :1 sand)
including cost of all materials, labour charges, HOM ofmachinery complete
as per specifications.Specification No. KBS 0.5-1.2 Cum 7934.00

1.2 KSRB 0.5-1.2 : Providing cement mortar of mix 1:2(1 cement :2 sand)
including cost of all materials, labour charges, HOM ofmachinery complete
as per specifications. Specification No. KBS 0.5-1.2 Cum 6370.00

1.3 KSRB 0.5-1.3 : Providing cement mortar of mix 1:3 (1 cement : 3 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 Cum 5591.00

1.4 KSRB 0.5-1.4 : Providing cement mortar of mix 1:4 (1 cement :4 sand)
including cost of all materials, labour charges, HOM ofmachinery complete
as per specifications. Specification No. KBS 0.5-1.2 Cum 4817.00

1.5 KSRB 0.5-1.5 : Providing cement mortar of mix 1:5 (1 cement :5 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 Cum 4401.00

1.6 KSRB 0.5-1.6 : Providing cement mortar of mix 1:6 (1 cement :6 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 Cum 4044.00

1.7 KSRB 0.5-1.7 : Providing cement mortar of mix 1:8 (1 cement :8 sand)
including cost of all materials, labour charges, HOM ofmachinery complete
as per specifications. Specification No. KBS 0.5-1.2 Cum 3688.00

1.8 KSRB 0.5-1.8 : Providing cement mortar of mix 1:10 (1 cement :10 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-1.2 Cum 3450.00

1.9 KSRB 0.5-2.1 : Providing lime mortar of mix 1:1 (1 lime putty :1 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 Cum 5754.00

1.10 KSRB 0.5-2.2 : Providing lime mortar of mix 1:2 (1 lime putty :2 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 Cum 5087.00

1.11 KSRB 0.5-2.3 : Providing lime mortar of mix 1:3 (1 lime putty :3 sand)
including cost of all materials, labour charges, HOM of machinery complete
as per specifications. Specification No. KBS 0.5-2.1 Cum 4760.00

1.12 KSRB 0.5-3.1 : Providing lime surkhi mortar of mix 1:1 (1 lime putty: 1
surkhi) including cost of all materials, labour charges, HOM of machinery Cum 4614.00
complete as per specifications. Specification No. KBS
1.13 KSRB 0.5-3.2 : Providing lime surkhi mortar of mix 1:2 (1 lime putty : 2
surkhi) including cost of all materials, labour charges, HOM of machinery Cum 3567.00
complete as per specifications. Specification No. KBS
1.14 KSRB 0.5-3.3 : Providing lime surkhi mortar of mix 1:3 (1 lime putty :3
surkhi) including cost of all materials, labour charges, HOM of machinery Cum 3047.00
complete as per specifications. Specification No. KBS
1.15 KSRB 0.5-4.1 : Providing lime surkhi sand mortar of mix 1:1:1 (1 lime
putty : 1 surkhi : 1 sand) including cost of all materials, labour charges,
HOM of machinery complete as per specifications. Specification No. KBS Cum 4272.00

1.16 KSRB 0.5-4.1 : Providing lime surkhi sand mortar of mix 1:1:2 (1 lime
putty : 1 surkhi : 2 sand) including cost of all materials, labour charges,
HOM of machinery complete as per specifications. Specification No. KBS Cum 3427.00

Page No. 02
1.17 KSRB 0.5-5.1 : Providing cement mortar with stone dust/grit of mix 1:2
(1 cement : 2 stone dust/grit) including cost of all materials, labour
charges, HOM of machinery complete as per specifications. Specification Cum 5689.00
No. KBS

Page 1 of 375
1.18 KSRB 0.5-6.1: Providing cement lime mortar of mix 1:1:3 (1 cement :
1lime putty:3 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 6812.00

1.19 KSRB 0.5-6.2: Providing cement lime mortar of mix 1:1:4 (1 cement :
1lime putty:4 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 6398.00

1.20 KSRB 0.5-6.3: Providing cement lime mortar of mix 1:1:5 (1 cement :
1lime putty:5 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 6116.00

1.21 KSRB 0.5-6.4: Providing cement lime mortar of mix 1:1:6 (1 cement :
1lime putty:6 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 5568.00

1.22 KSRB 0.5-6.5: Providing cement lime mortar of mix 1:1:7 (1 cement :
1lime putty:7 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 5260.00

1.23 KSRB 0.5-6.6: Providing cement lime mortar of mix 1:1:8 (1 cement :
1lime putty:8 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 4981.00

1.24 KSRB 0.5-6.7: Providing cement lime mortar of mix 1:2:9 (1 cement :
2lime putty:9 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 5359.00

1.25 KSRB 0.5-6.8: Providing cement lime mortar of mix 1:3:12 (1 cement :
3lime putty:12 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.3 Cum 5264.00

1.26 KSRB 0.5-7.1 : Providing white cement mortar with marble dust of mix
1:2 (1 white cement : 2 marble dust) including cost of all materials,
labour charges, HOM of machinery complete as per specifications. Cum 14379.00
Specification No. KBS
1.27 KSRB 0.5-7.2 : Providing white cement mortar with marble dust of mix
1:3 (1 white cement : 3 marble dust) including cost of all materials,
labour charges, HOM of machinery complete as per specifications. Cum 11287.00
Specification No. KBS
1.28 KSRB 0.5-7.3 : Providing white cement mortar with marble dust of mix
1:4 (1 white cement : 4 marble dust) including cost of all materials,
labour charges, HOM of machinery complete as per specifications. Cum 8825.00
Specification No. KBS
1.29 KSRB 0.5-7.4 : Providing white cement mortar with marble dust of mix
1:5 (1 white cement : 5 marble dust) including cost of all materials,
labour charges, HOM of machinery complete as per specifications. Cum 7500.00
Specification No. KBS
1.30 KSRB 0.5-8.1 : Providing fly ash sand mortar of mix 1:1.5:3 (1 cement :
1.5 fly ash : 3 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 3901.00

Page No. 03
1.31 KSRB 0.5-8.2 : Providing fly ash sand mortar of mix 1:2:4 (1 cement : 2
fly ash : 4 sand) including cost of all materials, labour charges, HOM of
machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 3366.00

1.32 KSRB 0.5-8.3 : Providing fly ash sand mortar of mix 1:2.5:5 (1 cement :
2.5 fly ash : 5 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 3069.00

1.33 KSRB 0.5-8.4 : Providing fly ash sand mortar of mix 1:3:6.5 (1 cement :
3 fly ash : 6.5 sand) including cost of all materials, labour charges, HOM
of machinery complete as per specifications. Specification No. KBS 0.5-2.4 Cum 2831.00

1.34 Mud Mortar Cum 278.00


Page No. 04

2.0 EARTHWORK FOR BUILDINGS

Page 2 of 375
2.1 KSRB 2-1.1 : Earthwork in surface excavation in ordinary soil for levelling
and lowering the ground manually ( other than foundation of buildings,
culverts, road drains and trenches of pipe lines and cables ) and removing
the excavated stuff to a distance not exceeding 50m and lift upto 1.5m, Cum 249.00
excavated surface levelled and neatly dressed, disposed earth to be levelled
after breaking of clods and neatly dressed as per specifications.
specification. No. KBS 2.1(a) / 2.3.1

2.2 KSRB 2-1.2 : Earthwork in surface excavation in Hard soil for levelling and
lowering the ground manually ( other than foundation of buildings,
culverts, road drains and trenches of pipe lines and cables ) and removing
the excavated stuff to a distance not exceeding 50m and lift upto 1.5m,
excavated surface levelled and neatly dressed, disposed earth to be levelled Cum 349.00
after breaking of clods and neatly dressed as per specifications.
specification. No. KBS 2.1(a) / 2.3.1. (P.No. 5/I.No. 2.2 of CSR 2015-16)

2.3 KSRB 2-2.1 : Earthwork excavation for foundation of buildings, water


supply, sanitary lines and electrical conduits either in pits or in trenches
1.5m and above in width, in ordinary soil not exceeding 1.5 m. in depth
including dressing the bottom and sides of pits and trenches, stacking the Cum 299.00
excavated soil clear from edges of excavation with lead upto 50 m. after
breaking of clods complete as per specifications. specification. No. KBS
2.1(a) / 2.3.5

2.4 KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water


supply, sanitary lines and electrical conduits either in pits or in trenches
1.5m and above in width, in hard soil not exceeding 1.5 m. in depth
including dressing the bottom and sides of pits and trenches, stacking the
excavated soil clear from edges of excavation with lead upto 50 m. after Cum 449.00
breaking of clods complete as per specifications. specification. No. KBS
2.1(b) / 2.3.5. (P.No. 5/I.No. 2.4 of CSR 2015-16)

2.5 KSRB 2-2.3 : Excavation 1.5m and above in width in soft rock by blasting
for foundation of buildings, water supply, sanitary lines and electrical
conduits either in pits or in trenches not exceeding 1.5 m. in depth,
stacking the excavated stuff from edges of excavation with lead upto 50m Cum 686.00
including cost of explosives, labour and HOM of equipment complete as per
specifications. specification. No. KBS 2.1.C / 2.9.4 / 2.18 / 2.19

2.6 KSRB 2-2.4 : Excavation 1.5m and above in width in soft rock without
blasting for foundation of buildings, water supply, sanitary lines and
electrical conduits either in pits or in trenches not exceeding 1.5 m. in
depth, stacking the excavated stuff from edges of excavation with lead upto Cum 1421.00
50m including cost of explosives, labour and HOM of equipment complete
as per specifications. specification. No. KBS 2.1.C / 2.9.4 / 2.18 / 2.19

2.7 KSRB 2-2.5 : Excavation 1.5m and above in width in hard rock by blasting
for foundation of buildings, water supply, sanitary lines and electrical
conduits either in pits or in trenches not exceeding 1.5 m. in depth,
stacking the excavated stuff from edges of excavation with lead upto 50m Cum 739.00
including cost of explosives, labour and HOM of equipment complete as per
specifications. specification. No. KBS 2.1.d / 2.3.4 / 2.18 / 2.19

2.8 KSRB 2.2.6 : Excavation 1.5m and above in width in hard rock by
chiselling and / or wedging, where blasting is prohibited for foundation of
buildings, water supply, sanitary lines and electrical conduits either in pits
or in trenches 1.5 m. in depth stacking the excavated stuff clear from the Cum 2042.00
edge of excavation with lead upto 50m including cost of labour complete as
per specifications. Specification. No. KBS

2.9 KSRB 2.2.7: Benching hard rock 5 to 7.5 cm depth. for seating of
foundation, including cost of all labour complete as per specifications. Sqm 2192.00
specification. No. KBS 2.1(a) / 2.3.1
Page No. 06
2.10 KSRB 2-3 : Filling available excavated earth (excluding rock ) in sides of
foundation upto plinth in layers not exceeding 20cms. In depth, compacting
each deposited layer by ramming after watering with lead upto 50m. And Cum 201.00
lift upto 1.5m. Including cost of all labour complete as per specifications.
Specificaton. No. KBS 2.9
2.11 KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not
exceeding 20cms in depth, compacting each deposited layer by ramming
after watering with lead upto 50m. and lift upto 1.5 m. including cost of all Cum 121.00
labour complete as per specifications.

Page 3 of 375
2.12 KSRB 2.5 : Earthwork excavation in soil deposits and filling sides of
foundation upto plinth in layers not exceeding 20cms. in depth, compacting
each deposited layer by ramming after watering with all lead and lift Cum 403.00
including cost of all labour complete as per specifications. specification.
No. KBS 2.9.9 / 2.9.10.1 / 2.1.1
2.13 KSRB 2.6 : Providing and filling sand in foundation upto plinth to
required depth for sub soil treatment including watering ramming with all
lead and lift complete as per specifications.specification. No. KBS 2.10.2 Cum 2060.00

2.14 KSRB 2.7 : Providing and removing shoring and strutting for protecting
the sides of foundation trenches, wherever required, including cost of all
materials and labour complete as per specifications. specification. No. KBS Sqm 450.00
2.5 / 2.13
2.15 KSRB 2.8 : Providing and Filling in foundation with granite / trap
broken metal 100mm. and down size, with approved sand including hand
packing, ramming, watering, including cost of all materials and labour with Cum 2429.00
all lead and lift. complete as per specifications. specification. No. KBS

2.16 KSRB 2.9 : Spreading and forming the excavated earth to required level,
slope for an average thickness of 75mm. in all classes of soils including
breaking clods and tamping manually alround the building and low laying Sqm 9.00
areas complete as per specifications.specification. No. KBS :

2.17 KSRB 2.10 : Providing sand cement bed with 5% cement with all leads for
all materials and lift of 1.5 m. machine mixed, laid in layers of 15cms. thick
and well compacted for foundation, including curing cost of materials Cum 2998.00
labour and HOM complete as per specifications. specification. No. KBS

2.18 KSRB 2.11 : Providing sand cement bed with 10% cement with all leads
for all materials and lift of 1.5 m. machine mixed, laid in layers of 15cms.
thick and well compacted for foundation, including curing cost of materials Cum 3425.00
labour and HOM complete as per specifications. specification. No. KBS

2.19 KSRB 2.12 : Providing sand piles with all leads and lift of 1.5 m. for
stabilising foundation after duly making 5 cms. dia holes to a depth of 1.2
to 1.5 m. at 0.5 m c to c and filling with sand and tamping wherever Sqm 323.00
required including cost of materials, labour complete as per specifications.

Page No. 07
2.20 KSRB 2.13 : Providing sand piles with all leads and lift of 1.5 m. for
stabilising foundation after duly making 5 cms. dia holes to a depth of 1.2
to 1.5 m. at 0.5 m c to c and filling with sand and tamping wherever Sqm 360.00
required including cost of materials, labour complete as per specifications.
sand and 10% cement.
2.21 KSRB 2.14-1: Extra for additional lift of 1.5m. or part thereof for
excavation In loose / soft or hard soil including cost of materials, labour Cum 20.00
complete as per specifications.
2.22 KSRB 2.14-2: Extra for additional lift of 1.5m. or part thereof for
excavation In loose / soft or hard soil including cost of materials, labour Cum 35.00
complete as per specifications. in soft or hard rock
2.23.1 Earth work excavation for foundation of structures by mechanical
means as per drawing and technical specification, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom, backfilling the excavation Cum 52.00
earth to the extent required and utilising / transporting the remaining
earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - in Ordinary/Hard
soil.

2.23.2 Earth work excavation for foundation of structures by mechanical


means as per drawing and technical specification, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom, backfilling the excavation Cum 68.00
earth to the extent required and utilising / transporting the remaining
earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - in Ordinary Rock
(Without blasting)

2.23.3 Earth work excavation for foundation of structures by mechanical


means as per drawing and technical specification, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom, backfilling the excavation Cum 741.00
earth to the extent required and utilising / transporting the remaining
earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - Ordinary/Hard
Rock (With blasting using explosives)

Page 4 of 375
2.23.4 Earth work excavation for foundation of structures by mechanical
means as per drawing and technical specification, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom, backfilling the excavation Cum 313.00
earth to the extent required and utilising / transporting the remaining
earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - Marshy soil-

2.24 Earth work for lowering and levelling the ground other than foundation
works by mechanical means upto 3.00 depth, including providing
shoring and strutting, removal of stumps and other deleterious matter,
dressing of sides and bottom, filling back the excavation earth to the extent Cum 61.00
required including the cost of labour & HOM of machineries, as per drawing
and technical specification.

Note :
KSRB 2.2. :
1.Excavation for foundations of buildings, water supply lines, electrical
conduits, either in pits of in trenches where excavation width is above 600
mm below 1.5 mtrs, depth add 25% extra and for width 600 mm add 50%
extra for respective rates due to restricted conditions.

KSRB 2-2
2.Extra for excavtion under water conditions and /or foul conditions
including bailing/ pumping out, removing slush add 20% of the rate of the
respective rate on account of slow progress of work under these conditions.

KSRB 2.3, 2.4 & 2.9


3. Royalty charges need not be deducted for these items
Page No. 8

3.0 ANTI TERMITE TREATMENT


3.1 KSRB-3.1 Supplying chloropyriphos emulisifiable concentrate of 20%,
in sealed containers including delivery as specified sales tax, transport,
Insurance and other levies complete as per specifications. Specification No. L 205.00
KBS
3.2 KSRB-3.2: Providing and injecting chemical emulsion for Pre-
constructional Anti-Termite Treatment, creating continuous chemical
barrier under and around the column pits, walls, trenches, basement
excavation, top surface of the plinth filling, junction of wall and floor,
along the external perimeter of building, expansion joints, over the top
surface of consolidated earth on which apron is to be laid, surrounding of
pipes and conduits, with chloropyriphos emulsifiable concentrates of 20% Sqm 106.00
concentration, including cost of chemical, diluting in water to one percent
concentration, labour, HOM of equipments, complete as per specifications.
(Plinth area of the building at ground floor only shall be measured )
Specification No. KBS : 3.2.6 / 3.2.7

3.3 KSRB-3.3 : Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment along external walls where the apron is not
provided using chemical emulsion at 7.5 Litre/sqm of the vertical surface of
the substructure to a depth of 300mm. Including excavation of channel
along the wall and redoing with chlorophyriphos emulsion concentrate 20% m 86.00
diluting in water to 1% concentration, including cost of chemicals, diluting
in water to one percent concentration, labour, HOM of equipments,
complete as per specifications. Specification No. KBS : 3.3.3

3.4 KSRB-3.4: Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment along external walls below concrete or
masonry apron using chemical emulsion at 2.25 litre/m. including drilling
and plugging of holes, with chlorophyriphos emulsion concentrate 20%
diluting in water to 1% concentration, including cost of chemicals, diluting m 46.00
in water to one percent concentration, labour, HOM of equipments,
complete as per specifications. Specification No. KBS : 3.3.4

3.5 KSRB 3.5: Providing, injecting chemical emulsion for Pre-constructional


Anti-Termite Treatment of soil under existing floors using chemical
emulsion at one litre / hole 30mm apart including drilling 12mm. dia holes
and plugging with cement mortar 1:2 proportion to match with the existing
floors with chlorophyriphos emulsion concentrate 20%, including cost of Sqm 251.00
chemical diluting in water to one percent concentration, labour, HOM of
equipments, complete as per specifications. (P. No. 9/ I. No. 3.5 of CSR
2015-16)

Page 5 of 375
3.6 KSRB.3-6: Providing, Injecting chemical emulsion for Pre-constructional
Anti-Termite Treatment of existing masonry using chemical emulsion at
one liter / hole at 300mm intervals including drilling of holes at 45 degree
and plugging them with cement mortar 1:2 to the full depth of the hole with
Chloropyriphos emulsifiable concentration 20% including cost of chemical m 79.00
diluting in water to one percent concentration, labour, HOM of
equipments, complete as per specifications. Specification No. KBS : 3.3.5

Page No. 10
3.7 KSRB 3.7: Providing, injecting chemical emulsion for Pre-constructional
Anti-Termite Treatment at points of contacts of wood work by chemical
emulsion Chloropyriphos ( in oil or kerosene based solution ) at 0.5 liters
per hole by drilling 6mm. dia holes at downword angle of 45 degree at
150mm. c to c and sealing the same including cost of chemicals, diluting in m 251.00
water to one percent concentration, labour, HOM of equipments, complete
as per specifications. Specification No. KBS : 3.3.7

3.8 Providing general disinfection services, spraying of insecticide and


pesticide inside and outside the building ( flies, bedbugs,lizards,
cockroaches, spiders caterpillars etc., including cost of materials labour Sqm 29.00
lead lift, hire charges of equipments etc., complete.
Page No. 11

4.0 CEMENT CONCRETE


4.1 KSRB 4-1.1: Providing and laying in position plain cement concrete of
mix 1:2:4 with OPC cement @ 240kgs, with 40mm and down size graded
granite metal coarse aggregates @0.878cum and fine aggregates @
0.459cum machine mixed, concrete laid in layers not exceeding 15 cms. Cum 5283.00
thick, well compacted, in foundation, including cost of all materials,
labour, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1, 4.2

4.2 KSRB 4-1.2 : Providing and laying in position plain cement concrete of
mix 1:3:6 with OPC cement @ 220kgs, with 40mm and down size graded
granite metal coarse aggregates @0.892cum and fine aggregates @
0.465cum machine mixed, machine mixed, concrete laid in layers not
exceeding 15 cms. thick, well compacted, in foundation including cost of Cum 5194.00
all materials, labour, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1, 4.2. (P.No. 12/I.No. 4.2 of CSR
2015-16)

4.3 KSRB 4-1.3 : Providing and laying in position plain cement concrete of
mix 1:4:8 with OPC cement @ 180kgs, with 40mm and down size graded
granite metal coarse aggregates @0.85cum and fine aggregates @ 0.57cum
machine mixed, machine mixed, concrete laid in layers not exceeding 15
cms. thick, well compacted, in foundation, including cost of all materials, Cum 5102.00
labour, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1, 4.2. (P.No.12, I.No. 4.3 of PWD SR 2015-16)

4.4 KSRB 4-1.4 : Providing and laying in position plain cement concrete of
mix 1:5:10 with OPC cement @ 160kgs, with 40mm and down size graded
granite metal coarse aggregates @0.86cum and fine aggregtes @ 0.58cum
machine mixed, machine mixed, concrete laid in layers not exceeding 15
cms. thick, well compacted, in foundation, including cost of all materials, Cum 5015.00
labour, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1, 4.2. (P.No.12, I.No. 4.4 of PWD SR 2015-16)

4.5 KSRB 4-1.5 : Providing and laying in position plain cement concrete of
mix M20 with OPC cement @ 300kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.43cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well Cum 5328.00
compacted, in foundation, plinth and cills, including cost of all materials,
labour, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1, 4.2. (P.No.12, I.No. 4.5 of PWD SR 2015-16)

4.6 KSRB 4-1.6 ; Providing and laying in position plain cement concrete of
mix 1:2:4 with cement @ 240kgs, with 20mm and down size graded granite
metal coarse aggregates @ 0.69 cum and fine aggregtes @ 0.459cum,
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well
compacted, in foundation, plinth and cills, ncluding cost of all materials, Cum 5422.00
labour, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1, 4.2. (P.No.12, I.No. 4.6 of PWD SR 2015-16)

Page 6 of 375
4.7 KSRB 4-1.7 : Providing and laying in position plain cement concrete of
mix 1:3:6 with OPC cement @ 220kgs, with 20mm and down size graded
granite metal coarse aggregates @0.84cum and fine aggregtes @ 0.56cum,
machine mixed, concrete laid in layers not exceeding 15 cms. thick, well Cum 5309.00
compacted, in foundation, plinth and cills, ncluding cost of all materials,
labour, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1, 4.2

Page No. 13
4.8 KSRB 4-1.8 : Extra for laying cement concrete under water including
cost of pumping or dewatering and clearing slush as per specifications. Cum 153.00
Specification No. KBS 4.2, 4.8
4.9 KSRB 4-1.9 : Extra for laying cement concrete under foul conditions.
Cum 220.00
Specification No. KBS
4.10 KSRB 4.2.1 : Providing and laying in position reinforced cement concrete
of Design mix M25 with OPC cement @ 340kgs, with 20mm and down size
graded granite metal coarse aggregates @0.70 cum and fine aggregtes @
0.47cum, with super plasticisers @ 3 liters confirming to is 9103-1999
reafirmed-2008 at machine mixed, concrete laid in layers not exceeding 15
cms thick, vibrated for all works in foundation for footings, pedastals,
retaining walls, return walls, walls (any thickness) including attached Cum 5812.00
pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor
blocks & plinths etc., including cost of all materials, labour, HOM of
machinery, curing, complete but excluding cost of reinforcement as per
specifications. Specification No. KBS 4.1, 4.6

4.11 KSRB 4.2.2 : Providing and laying in position reinforced cement concrete
of Design mix M20 with OPC cement @ 320kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregtes @
0.460 cum, with super plasticisers @ 3 liters confirming to is 9103-1999
reafirmed-2008, machine mixed, concrete laid in layers not exceeding 15
cms thick, vibrated for all works in foundation for footings, pedastals,
retaining walls, return walls, walls (any thickness) including attached Cum 5659.00
pilasters, columnspillars, posts, struts, buttresses, bed blocks, anchor
blocks & plinths etc., including cost of all materials, labour, HOM of
machinery, curing, complete but excluding cost of reinforcement as per
specifications. Specification No. KBS 4.1, 4.6

4.12 KSRB 4.2.7 : Providing and laying in position reinforced cement concrete
of design mix M25 with OPC cement @ 340kgs, with 20mm and down size
graded granite metal coarse aggregates @0.70cum and fine aggregtes @
0.47cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15
cms thick, vibrated for all works in ground floor level for roof slabs,
staircase, lintles and beams retaining walls, return walls, walls (any
thickness) including attached pilasters, columns, ,pillars, posts, struts, Cum 6045.00
buttresses, string or lacing courses, parapets, coping, bed blocks,
anchor blocks, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing, complete but excluding cost
of reinforcement as per specifications. Specification No. KBS 4.1, 4.6

4.13 KSRB 4.2.8: Providing and laying in position reinforced cement concrete
of design mix M20 with OPC cement @ 320kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15
cms thick, vibrated for all works in ground floor level for roof slabs,
staircase, lintles, and beams retaining walls, return walls, walls (any
thickness) including attached plasters, columns, pillars, posts, struts, Cum 5892.00
buttresses, string or lacing courses, parapets, coping, bed blocks,
anchor blocks, plain window cills, fillets etc., including cost of all
materials, labour, HOM of machinery, curing, complete but excluding cost
of reinforcement as per specifications. Specification No. KBS 4.1, 4.6. (P.
No. 14/ I.No. 4.13 of CSR 2015-16)

Page No. 14

Page 7 of 375
4.19 KSRB 4.2.10 : Providing and laying in position reinforced cement
concrete of design mix M20 with OPC cement @ 24kgs, with 12mm and
down size graded granite metal coarse aggregates @0.05175cum and fine
aggregtes @ 0.0345cum, with superplastisiser @0.225lts, machine mixed,
well compacted for plain chajja of 7.5 cms. average thickness, upto Sqm 440.00
ground floor level, including cost of all materials, labour, HOM of
machinery, finishing, curing, complete but excluding cost of reinforcement
as per specifications. Specification No. KBS 4.1, 4.6

4.20 KSRB 4.2.11 : Providing and laying in position reinforced cement


concrete of design mix M20 with OPC cement @ 27.20kgs, with 12mm
and down size graded granite metal coarse aggregates @0.05865cum and
fine aggregtes @ 0.0391cum, with superplastisiser @0.225lts, machine
mixed, well compacted for plain chajja of 8.5 cms. average thickness, upto Sqm 496.00
ground floor level, including cost of all materials, labour, HOM of
machinery, finishing, curing, complete but excluding cost of reinforcement
as per specifications. Specification No. KBS 4.1, 4.6

4.21 KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C.
chajja with plastering ( labour charges only ) as per specifications.
Specification No. KBS. (P. No. 14/ I.No. 4.21 of CSR 2015-16) m 33.00

4.22 KSRB 4-3.1 : Extra if vibrator is used for Item No.4-1 to 4-8 as per
Cum 14.00
specifications. Specification No. KBS 4.2.6
4.23 KSRB 4-3.2 : Deduct where machine mixing is not done Specification No.
Cum 14.00
KBS 4.2.2.5 / 4.3.2.2
4.24 KSRB 4-4.1 : Extra for use of water proofing compound in Cement
concrete of mix 1:1:2,at one kg of compound per bag of cement. Cum 209.00
Specification No. KBS
4.25 KSRB 4-4.2 : Extra for use of water proofing compound in Cement
concrete of mix 1:1.5:3,at one kg of compound per bag of cement. Cum 155.00
Specification No. KBS
4.26 KSRB 4-4.3 : Extra for use of water proofing compound in Cement
concrete of mix 1:2:4,at one kg of compound per bag of cement. Cum 124.00
Specification No. KBS
4.27 KSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5cms thick
with 6mm dia mild steel bars at 20 cms. c to c both horizontally and
vertically fixing chicken mesh for drop chajja, facia, backing to cup boards
including cost of all materials, labour, providing and removing form work Sqm 1072.00
HOM of machineries, curing, complete as per specifications. Specification
No. KBS
Page No. 14
4.28 KSRB 4-6.1 : Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for foundations, footings, bases of
columns for mass concrete including cost of all materials, labour complete Sqm 258.00
as per specificaitons. Specification No. KBS 4.6.2

4.29.2 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 400.00
ground level. - 0 to 5 mtrs. Specification No. KBS 4.6.2

4.29.3 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 580.00
ground level. - 0 to 6 mtrs. Specification No. KBS 4.6.2

4.29.4 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 750.00
ground level. - 0 to 7 mtrs. Specification No. KBS 4.6.2

4.29.5 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 920.00
ground level. - 0 to 8 mtrs. Specification No. KBS 4.6.2

Page 8 of 375
4.29.6 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 1170.00
ground level. - 0 to 9 mtrs. Specification No. KBS 4.6.2

4.29.7 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 1430.00
ground level. - 0 to 10 mtrs. Specification No. KBS 4.6.2

4.29.8 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 1690.00
ground level. - 0 to 11 mtrs. Specification No. KBS 4.6.2

4.29.9 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 1940.00
ground level. - 0 to 12 mtrs. Specification No. KBS 4.6.2

4.29.10 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 2190.00
ground level. - 0 to 13 mtrs. Specification No. KBS 4.6.2

4.29.11 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 2460.00
ground level. - 0 to 14 mtrs. Specification No. KBS 4.6.2

4.29.12 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 2780.00
ground level. - 0 to 15 mtrs. Specification No. KBS 4.6.2

4.29.13 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for suspended floors, landings,
balconies and likes, thickness upto 200 mm including cost of all materials,
labour complete as per specificaitons for heights more than 3.50m from Sqm 3080.00
ground level. - 0 to 16 mtrs. Specification No. KBS 4.6.2

4.30 KSRB 4-6.3 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for flat surface such as
suspended floors, roofs, landings, balconies and likes, thickness above 200 Sqm 440.00
mm including cost of all materials, labour complete as per Specification.
Specification No. KBS 4.6.2
4.31 KSRB 4-6.4 : Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for vertical surface such as walls
at any thickness, including attached pilasters, buttresses, plinth cills and Sqm 358.00
string courses cost of all materials, labour complete as per specifications.
Specification No. KBS 4.6.2
4.32 KSRB 4-6.5 : Providing and removing centering, shuttering, strutting,
propping etc., for columns, pillars, post and struts, square /
rectangular/ polygon in plan including cost of all materials, labour Sqm 456.00
complete as per specifications. Specification No. KBS 4.6.2
4.33 KSRB 4-6.6 : Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for columns, pillars,post and
struts, circular or curved in plan including cost of all materials, labour Sqm 913.00
complete as per specifications. Specification No. KBS 4.6.2

Page No. 16

Page 9 of 375
4.34 KSRB 4-6.7 :Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for sides and soffits of beams,
beam haunchings, cantilever girders, bressumers and lintels not
exceeding 1m in depth including cost of all materials, labour complete as Sqm 292.00
per specifications. Specification No. KBS 4.6.2

4.35 KSRB 4-6.8 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for sides and soffits of beams,
beams haunchings, cantilelver, girders, bressumers and lintels
exceeding 1m in depth including cost of all materials, labour complete as Sqm 403.00
per specifications. Specification No. KBS 4.6.2

4.36 KSRB 4-6.9 :Providing and removing centering, shuttering, strutting,


propping etc., for edges of slabs and breaks in floor including cost of all
materials, labour complete as per specifications. Specification No. KBS Sqm 755.00
4.6.2
4.37 KSRB 4-6.10 :Providing and removing centering, shuttering, strutting,
propping etc., for chajjas, corbels etc., including edges including cost of all
materials, labour complete as per specifications. Specification No. KBS Sqm 323.00
4.6.2
4.38 KSRB 4-6.11 :Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for Stairs (excluding landing)
except spiral staircase including cost of all materials, labour complete as Sqm 520.00
per specificaiton. Specification No. KBS 4.6.2

4.39 KSRB 4-6.12 :Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for cornices and mouldings
including cost of all materials, labour complete as per specifications. Sqm 511.00
Specification No. KBS 4.6.2
4.40 KSRB 4-6.13 :Providing and removing, centering, shuttering, strutting,
propping etc., and removal of form work for vertical fins and vertical sun
breakers including cost of all materials, labour complete as per Sqm 597.00
specifications. Specification No. KBS 4.6.2
4.41 KSRB 4-6.14 :Providing and removing centering, shuttering, strutting,
propping etc., and removal of form work for sloping or battering surface
including folded plates where inclination to horizontal plane does not
exceed 30 degree requiring shuttering only on the under side including Sqm 512.00
cost of all materials, labour complete as per specifications. Specification No.
KBS 4.6.2

4.42 KSRB 4-6.15 : Providing and removing centering, shuttering, strutting,


propping etc., and removal of form work for where inclination to horizontal
plane exceeds 30 degree (where shuttering may be provided both on
under side and upper side if required) including cost of all materials, labour Sqm 811.00
complete as per specifications. Specification No. KBS 4.6.2

Page No. 17
4.43.1 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using
10-15 cms. dia best quality casurina poles of 4m over all length (3m +0.5m
projection + 0.5m In to the ground), the distance between two rows being
1.25m and spacing of posts being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2 m c to c including m 336.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications.

4.43.2 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using
10-15 cms. dia best quality casurina poles of 4m over all length (3m +0.5m
projection + 0.5m In to the ground), the distance between two rows being
1.25m and spacing of posts being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2 m c to c including Cum 252.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications. - Scaffolding for stone masonry work converted to cum.

4.43.3 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using
10-15 cms. dia best quality casurina poles of 4m over all length (3m +0.5m
projection + 0.5m In to the ground), the distance between two rows being
1.25m and spacing of posts being 2m in both rows with 2 horizontal posts
with 0.5 mm overlap on either side and braces at 2 m c to c including Sqm 120.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications. - Scaffolding for stone masonry work converted to sqm.

Page 10 of 375
4.44.1 KSRB 4-8 : Providing two legged scaffolding for brick masonry work
using 10-15 cms. dia best quality Casurina poles of 4m over all length (3m
+0.5m projection + 0.5m In to the ground) the distance between two rows
being 1.25m and spacing of post being 2m in both rows with 2 horizontal
posts with 0.5 mm overlap on either side and braces at 2 m c to c including Cum 250.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications - for non modular brick work (Non modular standard
bricks : 4x0.23x3=2.76 cum)

4.44.2 KSRB 4-8 : Providing two legged scaffolding for brick masonry work
using 10-15 cms. dia best quality Casurina poles of 4m over all length (3m
+0.5m projection + 0.5m In to the ground) the distance between two rows
being 1.25m and spacing of post being 2m in both rows with 2 horizontal
posts with 0.5 mm overlap on either side and braces at 2 m c to c including Cum 290.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications - for modular brick work (modular standard bricks :
4x0.20x3=2.40 cum)

4.44.3 KSRB 4-8 : Providing two legged scaffolding for brick masonry work
using 10-15 cms. dia best quality Casurina poles of 4m over all length (3m
+0.5m projection + 0.5m In to the ground) the distance between two rows
being 1.25m and spacing of post being 2m in both rows with 2 horizontal
posts with 0.5 mm overlap on either side and braces at 2 m c to c including Sqm 58.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications - for non modular brick work

4.44.4 KSRB 4-8 : Providing two legged scaffolding for brick masonry work
using 10-15 cms. dia best quality Casurina poles of 4m over all length (3m
+0.5m projection + 0.5m In to the ground) the distance between two rows
being 1.25m and spacing of post being 2m in both rows with 2 horizontal
posts with 0.5 mm overlap on either side and braces at 2 m c to c including Sqm 58.00
longitudinal and transveres middle braces to step up and providing
platform with casurina poles, forms tied up using coir rope complete as per
specifications - for modular brick work

4.46.2 KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work
including straightening, cutting, bending, hooking, placing in position,
lapping and / or welding wherever required, tying with binding wire and
anchoring to the adjoining members wherever necessary complete as per
design (laps, hooks and wastage shall not be measured and paid) cost of Tonne 70966.00
materials, labour, HOM of machinery complete as per specifications.
Specification No. KBS 4.6.3 - TMT bars Fe 500

4.46.3 KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work
including straightening, cutting, bending, hooking, placing in position,
lapping and / or welding wherever required, tying with binding wire and
anchoring to the adjoining members wherever necessary complete as per
design (laps, hooks and wastage shall not be measured and paid) cost of Tonne 71518.00
materials, labour, HOM of machinery complete as per specifications.
Specification No. KBS 4.6.3 - TMT bars Fe 550

4.47 Lift charges for steel of all diameters for additional floors over ground
floor per floor height of 3.5 m. or part thereof cost of labour, complete as
per specifications. (P.No. 18, I.No. 4.47 of PWD SR 2015-16) Tonne 748.00

4.48 Providing and laying cement concrete using 20 mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete (RMC) M 20
for R.C.C works laid in 15 cms thick layers and well compacted vibrating,
curing, for raft foundation column footing , main and secondary beams Cum 5444.00
with all lead and lifts etc., complete (exclusive of cost of steel and
fabrication charges.)

Page No. 18
4.49.1 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5444.00
and fabrication charges) - Ready mixed Cement concrete for Beams,
Staircase and Roof with M-20

Page 11 of 375
4.49.2 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5497.00
and fabrication charges) - Ready mixed Cement concrete for Beams,
Staircase and Roof with M-25

4.49.3 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5598.00
and fabrication charges) - Ready mixed Cement concrete for Beams,
Staircase and Roof with M-30

4.49.4 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5804.00
and fabrication charges) - Ready mixed Cement concrete for Beams,
Staircase and Roof with M-35

4.49.5 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 6009.00
and fabrication charges) - Ready mixed Cement concrete for Beams,
Staircase and Roof with M-40

4.49.6 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5084.00
and fabrication charges) - Ready mixed cement concrete with OPC 50%
+ GGBS 50% M-20

4.49.7 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5187.00
and fabrication charges) - Ready mixed cement concrete with OPC 50%
+ GGBS 50% M-25

4.49.8 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5392.00
and fabrication charges) - Ready mixed cement concrete with OPC 50%
+ GGBS 50% M-30

4.49.9 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5710.00
and fabrication charges) - Ready mixed cement concrete with OPC 50%
+ GGBS 50% M-35

4.49.10 Providing and laying cement concrete using 20mm and down size granite
coarse aggregates and fine aggregates of ready mixed concrete for RCC
works laid in 15 cm thick layers and well compacted including vibrating
curing etc., with all lead and lift etc., complete. (exculsive of cost of steel Cum 5893.00
and fabrication charges) - Ready mixed cement concrete with OPC 50%
+ GGBS 50% M-40

Note: The RMC should be obtained only from the plants certified by
the quality council of India as per letter No, CE, C&B, AE-2, 2015-16
Dt.02.09.2015.
4.51 Providing and mixing fibermesh MD(Multi Dimensional) Graded (fibermesh
inforce e3) fibrilated (interconnected bundles of fibers that open up during
the mix process) 100% virgin Polypropylene fibers contains no reprocessed
olefin materials and are specially manufactured with 25 individual unique
fiber design to an optimum gradation for use as complete secondary
reinforcement. Application per cubic meter shall equal a minimum of 0.1%
Cum 655.00
by volume (0.9kg per cubic meter) in the concrete. Fibermesh MD Graded
Polypropylene fibrilated fiber should confirm to ASTM C 1116 type III 4.1.3
ASTM C 1116 performance level 1% ASTM C 1339 (Minimum average
residual strength of 0.35 Mpa).

Page 12 of 375
4.52 Providing and mixing fibermesh stealth e3 Fibermesh150multi
dimensional graded multifilamenrt 100%virgin polypropylene fibres
contains no reprocesserd olfrin materials and are specifically manufactured
for use as concrete secondary reinforcement. Application per cubic meter Cum 360.00
shall be @ 0.9kg to 1.8kg per cum of concrete. Fibermesh stealth e3 shall
confirm to ASTM C 1116 type 111.4.106.

4.53 Providing and casting reinforced cement concrete racks with design mix
M20, granite or trap jelly 12mm and down size 5 cms thick and below with
reinforcements of 6mm dia MS bars at 15 cms. Centre to centre for main
reinforcement and at 30cms centre to centre for distribution including Cum 984.00
supports wherever necessary with burnt brick in CM 1:4 including centring,
form work, curing etc., complete (inclusive of cost of steel and fabrication
charges).

Page No. 19
4.54 Providing RCC loft (atta) 7.5cms thick with cement concrete design mix
M20 using clean granite or trap jelly of 20mm and down size with necessary
reinforcements at 20cms centre to centre as per design including form Sqm 429.00
work, centring, curing, etc., complete (exclusive of cost of steel and
fabrication charges).
4.55 Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and
down size jelly cement concrete design mix M20 including CM 1:3 plaster
finishing, curing etc., complete (excluding the cost of steel and fabrication Sqm 619.00
charges
4.56.1 Providing RCC design mix M20 using granite metal 20mm and down size
for 7.5 cms thick solid parapet or perforated as per design, specification
and directions.(exclusive of cost of steel and fabrication charges) including Sqm 420.00
necessary centring, form work and finishing smooth with CM (1:3) etc.,
complete. - 7.5 cms thick
4.56.2 Providing RCC design mix M20 using granite metal 20mm and down size
for 7.5 cms thick solid parapet or perforated as per design, specification
and directions.(exclusive of cost of steel and fabrication charges) including Sqm 639.00
necessary centring, form work and finishing smooth with CM (1:3) etc.,
complete. - 10cms thick
4.57 Providing and mixing Alkali resistant glass fibres HD12 to arrest plastic
shrinkage cracks and to provide as a secondary reinforcement in concrete
at 600 gms/cum of concrete and containing minimum 127 millions of fibres
of length 12 mm , diameter 14 microns specific gravity 2.68, modulus of Cum 300.00
elasticity 72 Gpa and having the aspect ratio (length / dia) of 857, including
cost of labour, materials and HOM of machineries etc complete (Note: Rate
of cum of concrete)

4.58 Providing and laying pervious concrete of mix M20 with OPC 320 kgs with
20mm size metal coarse aggregate at 0.69 cum and 12mm size aggregates
at 0.43 cum with chemical admixture at 1.44 kg/cum machine mixed, laid
in layer not exceeding 15 cm thick well compacted for foot path , drain bed, Cum 4868.00
all round building premises, parking area etc., including cost of all
materials, labour, HOM curing complete as per specifications.

Page No. 20
Lift Charges : An additional rate of Rs. 60.00 cum per floor may be
added for every additonal floo for items under Sl.No. 4.1, to 4.18, 4,19,
4,20, 4,27 4,28, 4,55, 4,57, 4,58, 4,58.2, 4.30 to 4.42, for 4.43 for
4.43 1 to 4.44.4 an additional rate of Rs. 5/floor may be added.
Centering height of 3.5 meters is considered for item No. 4.28, 4,30, to
4,44.4 An additional rates Rs. 20 shall be added for every additional meter
or part there of for the above limits.
usage of ground Granulated Blast Furance Slag as per IS-12089
Use of 25% of Ground Granulated Blast Furance Slag of minimum 380
mtsq. Per kg fineness to replace cement in the cement concrete nominal
mix as given below to economize and to reduce the concrete cost
proportionately.
The Different in cost of cement for RMC items shall be effected for every
price revision of cement
RMC : While using RMC, taking out the samples at works site is
mandotory for conducting necessary tests. It is the responsibility of the
contractor to assure and ensure quality of RMC at the work spots as per
design mix for which executive engineer shall obtain necessary test
certifiicates as per IS Standards.
TMT Steel : For all RCC works the Contractor shall purchases the TMT
Steel manufactuered by the authorised dealers and necessary physical tests
for the TMT Steel so procured shall be conducted. As per IS 1786 if
necessary chemical tests may also be insisted.

Page 13 of 375
For lapping steel reinforcement, preferably 25mm and above, only welding
spices shall be done.
Page No. 23

5.0 STONE WORK


5.1 KSRB 5-1.1 : Providing and constructing granite / trap / basalt rubble
stone masonry in foundation with mud mortar (uncoursed), bond stones at
two m. apart in each course including cost of materials, labour, curing Cum 2358.00
complete as per specifications. KBS 5.1.12
5.2 KSRB 5.1-2 : Providing and constructing granite / trap / basalt rubble
stone masonry in foundation with cement mortar 1:8 (uncoursed), bond
stones at two m. apart in each course including cost of materials, labour, Cum 3527.00
curing complete as per specifications.KBS 5.1.12
5.3 KSRB 5.1-3 : Providing and constructing granite / trap / basalt rubble
stone masonry in foundation with cement mortar 1:6 (uncoursed), bond
stones at two m. apart in each course including cost of materials, labour, Cum 3647.00
curing complete as per specifications.KBS 5.1.12
5.4 KSRB 5.2-1 : Providing and constructing granite / trap / basalt size stone
masonry in foundation with mud mortar, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart in each Cum 3502.00
course including cost of materials, labour, curing complete as per
specifications. KBS 5.1.12
5.5 KSRB 5.2-2 : Providing and constructing granite / trap / basalt size stone
masonry in foundation with cement mortar 1:8, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart in each Cum 4494.00
course including cost of materials, labour, curing complete as per
specifications. KBS 5.1.13
5.6 KSRB 5.2-3 : Providing and constructing granite / trap / basalt size stone
masonry in foundation with cement mortar 1:6, stone hammerd dressed in
courses not less than 20 cms high, bond stones at two m. apart in each Cum 4596.00
course including cost of materials, labour, curing complete as per
specifications. KBS 5.1.13
5.9 KSRB 5.3-3 : Providing and constructing granite / trap / basalt size stone
masonry in basement with cement mortar 1:6, edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart Cum 5483.00
in each course including cost of materials, labour, curing complete as per
specifications. KBS 5.1.13
5.12 KSRB 5.4-3 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:6 , edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart Cum 5784.00
in each course including cost of materials, labour, scaffolding, curing
complete as per specifications. KBS 5.1.13
5.13 KSRB 5.4-4 : Providing and constructing granite / trap / basalt size stone
masonry in superstructure with cement mortar 1:4 , edges of stones chistle
dressed in courses not less than 15 cms high, bond stones at two m. apart Cum 6005.00
in each course including cost of materials, labour, scaffolding, curing
complete as per specifications. KBS 5.1.13
5.14 KSRB 5-5 : Extra lift charges for size stone masonry above ground floor for
Cum 312.00
every additional floor. KBS 5.1.13
5.15 KSRB 5-6 : Extra for constructing stone masonry in square or rectangular
Cum 489.00
pillars complete as per specifications. KBS 5.1.13
Page No. 25
5.16 KSRB 5-7 : Extra for constructing masonry in circular pillars including cost
of extra materials and labour complete as per specifications. KBS 5.1.13 Cum 1109.00

5.17 KSRB 5-8.1 : Providing one line dressing to granite stone slab / granite
Sqm 897.00
stone masonry as per specifications .KBS 5.1.13
5.18 KSRB 5-8.2 : Providing two line dressing to granite stone slab / granite
Sqm 1495.00
stone masonry as per specifications. KBS 5.1.13
5.19 KSRB 5-8.3 : Proiding three line dressing to granite stone slab / granite
Sqm 2092.00
stone masonry as per specifications. KBS 5.1.13
5.20 KSRB 5-8.4 : Providing pulmane finish only on three line dressed surface as
Sqm 591.00
per specifications. KBS 5.1.13
5.21 KSRB 5-8.5 : Providing quoin dressing to stone masonry and stone slabs,
two line 5 cms wide on each face as per specifications.(measurement m 150.00
including mortar joints). KBS 5.1.13
5.22 KSRB 5-9 : Providing chamfering edges to stone slab 2.5 cms. wide as per
specifications. (only chamfered length shall be recorded) KBS 5.1.13 m 58.00

5.23 KSRB 5-10 : Providing hammer dressing to size stones as per specifications.
No 11.00
KBS 5.1.13.3

Page 14 of 375
5.24.1 KSRB 5-11 : Providing and constructing load bearing wall with cement
concrete cavities blocks ( hollow blocks ) of size 400x200x200 mm Grade B
having a minimum face shell thickness of 30mm and web thickness of
25mm with block density between 1100 kg/m3 and 1500 kg/m3 having a
minimum average compressive strength of 5.00 N/mm2 confirming to IS Sqm 916.00
2185 (Part) : 2005 and constructed with CM 1:4 , as per IS 2572:2005
including cost of all materials, labour charegs, scaffolding, curing complete
as per specifications. KBS No.5.4

5.24.2 KSRB 5-11 : Providing and constructing load bearing wall with cement
concrete cavities blocks ( hollow blocks ) of size 400x150x200 mm Grade B
having a minimum face shell thickness of 30mm and web thickness of
25mm with block density between 1100 kg/m3 and 1500 kg/m3 having a
minimum average compressive strength of 5.00 N/mm2 confirming to IS Sqm 904.00
2185 (Part) : 2005 and constructed with CM 1:4 , as per IS 2572:2005
including cost of all materials, labour charegs, scaffolding, curing complete
as per specifications. KBS No.5.4

5.25.1 KSRB 5-11 : Providing and constructing load bearing wall with cement
concrete cavities blocks ( hollow blocks ) of size 400x200x200 mm Grade B
having a minimum face shell thickness of 30mm and web thickness of
25mm with block density between 1100 kg/m3 and 1500 kg/m3 having a
minimum average compressive strength not lessthan 3.5 N/mm2 Sqm 916.00
confirming to IS 2185 (Part) : 2005 and constructed with CM 1:4 , as per IS
2572:2005 including cost of all materials, labour charegs, scaffolding,
curing complete as per specifications. KBS No.5.4

Page No. 26
5.25.2 KSRB 5-11 : Providing and constructing load bearing wall with cement
concrete cavities blocks ( hollow blocks ) of size 400x150x200 mm Grade B
having a minimum face shell thickness of 30mm and web thickness of
25mm with block density between 1100 kg/m3 and 1500 kg/m3 having a
minimum average compressive strength not lessthan 3.5 N/mm2 Sqm 891.00
confirming to IS 2185 (Part) : 2005 and constructed with CM 1:4 , as per IS
2572:2005 including cost of all materials, labour charegs, scaffolding,
curing complete as per specifications. KBS No.5.4

5.26.1 KSRB 5-11 : Providing and constructing load bearing wall with solid
concrete blocks of size 400x200x200 mm having block density not
lessthan 1800 kg/m3 and having a minimum average compressive strength
4.00 N/mm2 confirming to IS 2185 (Part) : 2005 and constructed with CM Sqm 962.00
1:4 , as per IS 2572:2005 including cost of all materials, labour charegs,
scaffolding, curing complete as per specifications. KBS No.5.4

5.26.2 KSRB 5-11 : Providing and constructing load bearing wall with solid
concrete blocks of size 400x150x200 mm having block density not
lessthan 1800 kg/m3 and having a minimum average compressive strength
4.00 N/mm2 confirming to IS 2185 (Part) : 2005 and constructed with CM Sqm 924.00
1:4 , as per IS 2572:2005 including cost of all materials, labour charegs,
scaffolding, curing complete as per specifications. KBS No.5.4

5.27.1 KSRB 5-11 : Providing and constructing load bearing wall with solid
concrete blocks of size 400x200x200 mm having block density not
lessthan 1800 kg/m3 and having a minimum average compressive strength
5.00 N/mm2 confirming to IS 2185 (Part) : 2005 and constructed with CM Sqm 912.00
1:4 , as per IS 2572:2005 including cost of all materials, labour charegs,
scaffolding, curing complete as per specifications. KBS No.5.4

5.27.2 KSRB 5-11 : Providing and constructing load bearing wall with solid
concrete blocks of size 400x150x200 mm having block density not
lessthan 1800 kg/m3 and having a minimum average compressive strength
5.00 N/mm2 confirming to IS 2185 (Part) : 2005 and constructed with CM sqm 953.00
1:4 , as per IS 2572:2005 including cost of all materials, labour charegs,
scaffolding, curing complete as per specifications. KBS No.5.4

5.28 KSRB 5-11 : Providing and constructing non load bearing wall with solid
concrete blocks of size 400x100x200 mm having block density not
lessthan 1800 kg/m3 and having a minimum average compressive strength
4.00 N/mm2 confirming to IS 2185 (Part) : 2005 and constructed with CM sqm 811.00
1:4 , as per IS 2572:2005 including cost of all materials, labour charegs,
scaffolding, curing complete as per specifications. KBS No.5.4

Page 15 of 375
5.29.1 Providing and fixing pre cast solid concrete kerb stones of size
450x200x400 mm made out of CC 1:2:4 and finished with CM 1:3 no 450.00
plastering and finishing cutting ete., complete.
5.29.2 Providing and fixing pre cast solid concrete kerb stones of size
450x150x500 mm made out of CC 1:2:4 and finished with CM 1:3 no 441.00
plastering and finishing cutting ete., complete.
5.30 Providing and fixing pre cast solid cement concrete kerb stones made out of
CC 1:2:4 with top and bottom width 114 and 165 mm respectively, 400mm
high and 450mm in length finished with CM 1:3 plastering and finishing
cutting including formwork, curing, including cost of materials, labour No 408.00
charges of machinery, loading and unloading, lead and lift, transportation
ete.,complete

5.31.1 Providing granite slabs of selected quality roughly dressed havinf a size of
7.5 cms thick and fixed in cement mortar (1:6) including fixing curing ete., Sqm 700.00
complete.
5.31.2 Providing granite slabs of selected quality roughly dressed havinf a size of
10 cms thick and fixed in cement mortar (1:6) including fixing curing ete., Sqm 912.00
complete.
5.32 Removing B.S slab of drain and stacking Sqm 99.00
5.33 Removing and refixing stone slabs of drains and pointing in CM (1:3) Sqm 105.00
Note: Additional rate of Rs. 35.00/Sqm for item nos. 5.24, 5.25, 5.26, 5.27,
5.28, 5.34 for every additional floor.
Page No. 27

6.0 6.BRICK WORK


6.1 KSRB 6-1.1 :Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 3.5 Newton per sqmm with mud mortar for basement and
superstructure including cost of materials, labour charges, scaffolding, Cum 5176.00
curing complete as per specifications Specification No. KBS 6.2.

6.2 KSRB 6-1.2 : Providing and constructing burnt brick masonry for basement
and superstructure with approved quality of non-modular bricks of
standard size of class designation 3.5Newton per sqmm with cement
mortar1:8 including cost of materials, labour charges, scaffolding, curing Cum 6124.00
complete as per specifications. Specification No. KBS 6.2

6.3 KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement
and superstructure with approved quality of non-modular bricks of
standard size of class designation 3.5Newton per sqmm with cement
mortar1:6 including cost of materials, labour charges, scaffolding, curing Cum 6212.00
complete as per specifications. Specification No. KBS 6.2

6.5 KSRB 6-2.2 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 5.0Newton per sqmm (table moulded) with cement mortar
1:8 for basement and superstructu/re including cost of materials, labour Cum 6600.00
charges, scaffolding, curing complete as per specifications. Specification No.
KBS 6.2

6.6 KSRB 6-2.3 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 5.0Newton per sqmm (table moulded) with cement mortar
1:6 for basement and superstructu/re including cost of materials, labour Cum 6709.00
charges, scaffolding, curing complete as per specifications. Specification No.
KBS 6.2

6.7 KSRB 6-2.4 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 5.0 Newton per sqmm with cement mortar 1:4 for basement
and superstructure including cost of materials, labour charges, scaffolding, Cum 6899.00
curing complete as per specifications. Specification No. KBS 6.2. (P.No.27,
I.No. 6.7 of PWD SR 2015-16)

6.8 KSRB 6-3.1 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 7.5Newton per sqmm with cement mortar 1:8 for basement
and superstructure (Machine moulded Wirecut bricks) with cost of Cum 9698.00
materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

Page 16 of 375
6.9 KSRB 6-3.2 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 7.5Newton per sqmm with cement mortar 1:6 for basement
and superstructure (Machine moulded Wirecut bricks) with cost of Cum 9785.00
materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

6.10 KSRB 6-3.3 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 7.5Newton per sqmm with cement mortar 1:4 for basement
and superstructure (Machine moulded Wirecut bricks) with cost of Cum 9975.00
materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

6.11 KSRB 6-3.4 : Providing and constructing burnt brick masonry with
approved quality of non-modular bricks of standard size of class
designation 7.5Newton per sqmm with cement mortar 1:3 for basement
and superstructure (Machine moulded Wirecut bricks) with cost of Cum 10166.00
materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2
Page No. 29
6.13 KSRB 6-4.2 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation 3.5Newton per sqmm with cement mortar 1:8 for
basement and superstructure with cost of materials, labour charges, Cum 6265.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2

6.14 KSRB 6-4.3 : Providing and constructing burnt brick masonry with
approved quality of modular bricks ground moulded of standard size of
class designation 3.5Newton per sqmm with cement mortar 1:6 for
basement and superstructure with cost of materials, labour charges, Cum 6342.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2

6.16 KSRB 6-5.2 : Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
5.0Newton per sqmm (table moulded) with cement mortar 1:8 for
basement and superstructure including cost of materials, labour charges, Cum 6805.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2

6.17 KSRB 6-5.3 : Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
5.0Newton per sqmm (table moulded) with cement mortar 1:6 for
basement and superstructure including cost of materials, labour charges, Cum 6881.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2

6.18 KSRB 6-5.4 : Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
5.0Newton per sqmm (table moulded) with cement mortar 1:4 for
basement and superstructure including cost of materials, labour charges, Cum 7047.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2

6.19 KSRB 6-6.1 : Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
7.5Newton per sqmm (Machine moulded Wirecut bricks) with cement
mortar 1:8 for basement and superstructure including cost of materials, Cum 10041.00
labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2

6.20 KSRB 6-6.2 : Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
7.5Newton per sqmm (Machine moulded Wirecut bricks) with cement
mortar 1:6 for basement and superstructure including cost of materials, Cum 10118.00
labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2

6.21 KSRB 6-6.3 : Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
7.5Newton per sqmm (Machine moulded Wirecut bricks) with cement
mortar 1:4 for basement and superstructure including cost of materials, Cum 10284.00
labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2

Page 17 of 375
6.22 KSRB 6-6.4 : Providing and constructing burnt brick masonry with
approved quality of modular bricks of standard size of class designation
7.5Newton per sqmm (Machine moulded Wirecut bricks) with cement
mortar 1:3 for basement and superstructure including cost of materials, Cum 10450.00
labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2

6.23 KSRB 6-7.1 : Construction of partition wall 11.2 cms thick with non
modular ground moulded burnt bricks of class designation 3.5 Newton
per sqmm with cement mortar 1:4 inlcuding providing and fixing plaster
mesh manufactured out of hot dipped galvanised iron of nominal thickness
0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including Sqm 838.00
cost of materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2. (P.No. 28, I.No. 6.23 of PWD SR
2015-16)

6.24 KSRB 6-7.2 : Construction of partition wall 11.2 cms thick with non
modular ground moulded burnt bricks of class designation 5.0 Newton
per sqmm with cement mortar 1:4 inlcuding providing and fixing plaster
mesh manufactured out of hot dipped galvanised iron of nominal thickness Sqm 920.00
0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including
cost of materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

Page No. 30
6.25 KSRB 6-7.3 : Construction of partition wall 11.2 cms thick with non-
modular ground moulded burnt bricks of class designation 3.5 Newton
per sqmm with cement mortar 1:4 including cost of materials, labour Sqm 815.00
charges, scaffolding, curing complete as per specifications. Specification No.
KBS 6.2
6.26 KSRB 6-7.4 : Construction of partition wall 11.2 cms thick with non-
modular ground moulded burnt bricks of class designation 5.0 Newton
per sqmm with cement mortar 1:4 including cost of materials, labour Sqm 884.00
charges, scaffolding, curing complete as per specifications. Specification No.
KBS 6.2
6.27 KSRB 6-8.1 :Construction of partition wall 10 cms thick with ground
moulded modular burnt bricks of class designation 3.5 Newton per
sqmm with cement mortar 1:4 including providing and fixing plaster mesh
manufactured out of hot dipped gelvanised iron of nominal thickness 0.35 Sqm 764.00
mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including cost of
materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

6.28 KSRB 6-8.2 : Construction of partition wall 10 cms thick with table
moulded modular burnt bricks of class designation 5.0Newton per
sqmm with cement mortar 1:4 including providing and fixing plaster mesh
manufactured out of hot dipped gelvanised iron of nominal thickness 0.35 Sqm 822.00
mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including cost of
materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

6.29 KSRB 6-8.3 :Construction of partition wall 10 cms thick with ground
moulded modular burnt bricks of class designation 3.5Newton per
sqmm with cement mortar 1:4 including cost of materials, labour charges, Sqm 728.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2

6.30 KSRB 6-8.4 : Construction of partition wall 10 cms thick with table
moulded modular burnt bricks of class designation 5.0 Newton per
sqmm with cement mortar 1:4 including cost of materials, labour charges, Sqm 786.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2

6.31 Providing and constructing approved quality of standard size precast FLY
ASH brick masonry with compresive strength not less than 3.5 Newton per
sqmm with cement mortar 1:6 for basement and superstructure with cost Cum 5217.00
of materials, labour charges, scaffolding, curing complete as per
specifications
6.32.1 Provinding and constructing non load bearing wall with Light Weight
Concrete (Autoclaved areated concrete) Blocks confirming to IS:2185
(part-3) 1984 and IS 6441-1972 of compressive strength of 3.0N/sq mm
with a thin layer of polymer based jointing solvent for super structure with Sqm 1125.00
neccesary scaffolding, curing including cost of all materials, labour, lead&
lift etc, complete as per specifications. - with 600x200x100mm size
Blocks

Page 18 of 375
6.32.2 Provinding and constructing non load bearing wall with Light Weight
Concrete (Autoclaved areated concrete) Blocks confirming to IS:2185
(part-3) 1984 and IS 6441-1972 of compressive strength of 3.0N/sq mm
with a thin layer of polymer based jointing solvent for super structure with Sqm 1504.00
neccesary scaffolding, curing including cost of all materials, labour, lead&
lift etc, complete as per specifications. - with 600x200x150mm size
Blocks

6.32.3 Provinding and constructing non load bearing wall with Light Weight
Concrete (Autoclaved areated concrete) Blocks confirming to IS:2185
(part-3) 1984 and IS 6441-1972 of compressive strength of 3.0N/sq mm
with a thin layer of polymer based jointing solvent for super structure with Sqm 1694.00
neccesary scaffolding, curing including cost of all materials, labour, lead&
lift etc, complete as per specifications. - with 600x200x200mm size
Blocks

6.32.4 Provinding and constructing non load bearing wall with Light Weight
Concrete (Autoclaved areated concrete) Blocks confirming to IS:2185
(part-3) 1984 and IS 6441-1972 of compressive strength of 3.0N/sq mm
with a thin layer of polymer based jointing solvent for super structure with Sqm 2067.00
neccesary scaffolding, curing including cost of all materials, labour, lead&
lift etc, complete as per specifications. - with 600x200x230mm size
Blocks

1.Lift charges : The Above rates are applicable for Ground only, An
Additional rate of Rs. 60.00 /cum and Rs. /sqm per floor may be added for
every additional floor above or below the ground floor.
2. Add 10% extra for gable portion
Page No. 31

7.0 STEEL AND ALUMINIUM WORK


7.1 KSRB 7.1 : Providing and fixing in position collapsible steel shutters with
single or double leaf with vertical channel 20mmx10mmx2mm braced with
flat iron diagonals 20mmx5mm size, with top and bottom rails of T iron
sections of 40x40x6 mm with 38mm dia steel pulleys complete with bolt
and nuts, locking arrangements, stoppers, handles on both sides with Sqm 5210.00
7.5cms openings at 10 cms. c to c applying a priming coat of red lead paint.
cost of materials, labour, HOM of machinery complete as per specifications.
size of gate 2.4mx1.4m. Specification No. KBS 7.7 / 7.12

7.2 KSRB 7.2 : Providing and fixing 1mm thick M.S. sheet sliding shutters
with frame and diagonal braces of 40x40x6 mm angle Iron 3.15mm thick
M.S. Gusset plates at junctions and corners, 25mm dia pulley, 40x40x6
mm angles and T iron guide rail top and bottom respectively with handles,
stoppers and locking arrangements etc., including applying a priming coat Sqm 3180.00
of red lead paint cost of materials, labour, HOM of machinery complete as
per specifications. 1 double leaf door of size 2.4x2.4m. Specification No.
KBS 7.8 / 7.12

7.3 KSRB 7.3 : Providing and fixing 1mm thick M.S. sheet garage door with
frame and diagonal braces of size 40x40x6 mm angle Iron, 3.15mm thick
M.S. Gusset plates at the junctions and corners, with handles, stoppers
and locking arrangements etc., including applying a priming coat of red
lead paint cost of materials, labour, HOM of machinery complete as per Sqm 2729.00
specifications. Double leaf door of size 2.4x2.4m. Specification No. KBS
7.9 / 7.12. (P.No. 31, I.No. 7.3 of CSR 2015-16)

7.4 KSRB 7.4 : Providing and fixing 1mm thick M.S. sheet garage door with
frame and diagonal braces of size 40x40x6 mm angle Iron, using M.S. flats
30x6 mm for diagonal braces and central cross pieces 3.15mm thick M.S.
Gusset plates at the junctions and corners, with handles, stoppers and
locking arrangements etc., including applying a priming coat of red lead Sqm 2133.00
paint cost of materials, labour, HOM of machinery complete as per
specifications. 1 double leaf door of size 2.4x2.4m. Specification No. KBS
7.9 / 7.12. (P.No. 31, I.No. 7.4 of CSR 2015-16)

Page 19 of 375
7.5 KSRB 7.5 : Providing and fixing pull and push type rolling shutters of
approved make out of 18 guage, 75mm wide cold rolled steel laths of convex
corrugation, with side guides and bottom rail, with interlocking
arrangements for steel laths by means of alternate clips, suspension shaft
with High tension coil type springs two numbers, mounted on specially
designed pipe shaft, with bracket plates, guide channels, ball bearing
arrangements, for inside & outside locking with push & pull operations
complete including pulling hooks, 4Nos. handles with all fittings and Sqm 2607.00
accessories, painted with a coat of red lead paint (without top cover) cost of
materials, labour, HOM of machinery complete as per specifications.
Shutter size 3mx2.8 m. Specification No. KBS 7.10 / 7.12. (P.No. 31, I.No.
7.5 of CSR 2015-16)

Page No. 33
7.6 KSRB 7.6 : Providing and fixing top covers made out of 20 guage M.S. sheet
over pull and push rolling shutters bent to shape including cost of red lead
primer coat of painting , materials, labour, HOM of machinery complete as m 482.00
per specifications. Specification No. KBS 7.10.6 / 7.12

7.7 KSRB 7.7 : Providing and fixing in position in cement concrete 1:3:6 steel
glazed windows and ventilators side hung/top hung fully openable as
per approved drawings using Z angles of 25x33x3mm, weighing 1.419
Kg/m both for outer and inner frames and central mullion section of size
25x46x3mm. weighing 2.28Kg/m duly providing T section 19x19x3mm
weighing 0.839 kg/m for glazing of windows not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood
beading of required size, all steel sections should confirm to I.S 7452:1990,
4nos. of holdfasts of approved size, section should be cut to length welded
and electrically grinded subdividing frames of unit shall be tenonned and Sqm 3898.00
revetted into the frames electrically. All the steel surface shall be throughly
cleaned free of rust and painted with one coat of anti-corosive paint and
finishing with two coats of ready mix paint of approved colour and make
including cost of materials, fixtures, labour and HOM of machinerycomplete
as per specifications. Specification No. KBS 7.12.1 / 7.12.2 / 7.12.3 / 7.12

7.8 KSRB 7.8 : Providing and fixing in position in cement concrete 1:3:6 steel
glazed windows and ventilators side hung/top hung 2/3 openable 1/3 fixed
as per approved drawings using Z angles of 25x33x3mm, weighing 1.419
kg/m both for outer and inner frames and central mullion section of size
25x46x3mm, weighing 2.28kg/m all duly providing T section 19x19x3mm
weighing 0.839 kg/m for glazing of windows, not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood
beading of required size, all steel sections should confirm to I.S 7452:1990,
4nos. of holdfasts of approved size, section should be cut to length welded Sqm 3328.00
and grinded electrically subdividing frames of unit shall be tenonned and
revetted into the frames electrically. All the steel surface shall be throughly
cleaned free of rust and painted with one coat of anti-corrosive paint and
finishing two coats of ready mix paint of approved colour and make
including cost of materials, fixtures, labour charges and HOM of machinery
complete as per specifications.

7.9 KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators
weighing 21kg/sqm using M.S. flats, or M.S. square rods, or combination of
M.S. flats and square rods as per approved design, drawing including
cutting steel sections and welding the same to required pattern with a coat
of red lead primer, cost of materials, fixtures, labour and HOM of Kgs 95.00
machinery complete as per specifications. Specification No. KBS 7.12.
(P.No. 32, I.No. 7.9 of PWD SR 2015-16)

Page No. 32

Page 20 of 375
7.10.1 KSRB 7.10 : Providing and fixing in position aluminium windows and
ventilators as per approved drawings with sliding shutters using double
track window frame section of size 61.85x31.75mm. with 1.2mm thick,
bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick
weight 0.659 kg/m; and shutter comprising top and bottom section of size
40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side
40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section
40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted
on nylon rollers with approved quality of fixtures such as aluminium
handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass
Sqm 4266.00
for shutters fitted with rubber beading aluminium sections including
cutting to required length, joints mitred subdividing the frame tenonned
and rivetted in the assembled frame stiffened with end clips at corners
angles etc., and fixed to the walls, lintels, floor beams/cills as the case may
be with necessary steel screws, raul plugs, or teak wood gatties including
cutting masonry or concrete and making good the original surface using
cement mortar, aluminium sections pretreated for removal of any
Specification No. KBS
using aluminium section anodized to 12 - 15 microns.

7.10.2 KSRB 7.10 : Providing and fixing in position aluminium windows and
ventilators as per approved drawings with sliding shutters using double
track window frame section of size 61.85x31.75mm. with 1.2mm thick,
bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick
weight 0.659 kg/m; and shutter comprising top and bottom section of size
40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side
40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section
40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted
on nylon rollers with approved quality of fixtures such as aluminium
handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass
Sqm 4375.00
for shutters fitted with rubber beading aluminium sections including
cutting to required length, joints mitred subdividing the frame tenonned
and rivetted in the assembled frame stiffened with end clips at corners
angles etc., and fixed to the walls, lintels, floor beams/cills as the case may
be with necessary steel screws, raul plugs, or teak wood gatties including
cutting masonry or concrete and making good the original surface using
cement mortar, aluminium sections pretreated for removal of any
Specification No. KBS
using aluminium section powdered coated to a minimum of 60-70 microns
with exterior durable pure polyester grade powder of approved quality.
7.11.1 (P.No.
KSRB 33, I.No.
7.11 7.10.2 of PWD
: Providing and SR 2015-16)
fixing in position aluminium windows and
ventilators as per approved drawings with sliding shutters using three track
window frame of size 92x31.75mm bottom section 1.3mm thick, weight
1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933
kg/m.shutter frame section comprising top and bottom section of size
40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side
outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter
interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight
0.469 kg/m, the shutters mounted on nylon rollers with approved quality of
fixtures such as aluminium handles tower bolts etc.; providing and fixing
Sqm 4351.00
5.5mm. thick plain glass for shutters fitted with rubber beading all
aluminium sections including cutting to required length, joints mitred
subdividing the frame tenonned and rivetted, in the assembled frame,
stiffened with end clips for corners, angles etc., and fixed to the walls,
lintels, floor beams/cills as the case may be, with necessary steel screws,
raul plugs or teak wood gatties including cutting masonry or concrete and
making good the original surface using cement mortar.
using aluminium section anodized to 12 - 15 microns.

7.11.2 KSRB 7.11 : Providing and fixing in position aluminium windows and
ventilators as per approved drawings with sliding shutters using three track
window frame of size 92x31.75mm bottom section 1.3mm thick, weight
1.07kg/m; sides and top sections 1.3 mm, thick, weight 0.933
kg/m.shutter frame section comprising top and bottom section of size
40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side
outer 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m, shutter
interlock section 40mmx26.7mm wall thickness 1.1 mm. thick, weight
0.469 kg/m, the shutters mounted on nylon rollers with approved quality of
fixtures such as aluminium handles tower bolts etc.; providing and fixing
Sqm 4473.00
5.5mm. thick plain glass for shutters fitted with rubber beading all
aluminium sections including cutting to required length, joints mitred
subdividing the frame tenonned and rivetted, in the assembled frame,
stiffened with end clips for corners, angles etc., and fixed to the walls,
lintels, floor beams/cills as the case may be, with necessary steel screws,
raul plugs or teak wood gatties including cutting masonry or concrete and
making good the original surface using cement mortar.
using aluminium section powdered coated to a minimum of 60-70 microns
with exterior durable pure polyester grade powder of approved quality.
(P.No. 33, I.No. 7.11.2 of PWD SR 2016-17)

Page 21 of 375
Page No. 35
7.12.1 KSRB 7.12 : Providing and fixing in position aluminium windows and
ventilators as per approved drawings with sliding shutters using four track
window frame of size 122.2x31.75mm. for bottom section 1.1mm thick,
weight 1.205 kg/m; sides and top sections 1.2 mm. thick weight 1.093
kg/m; shutter section comprising top and bottom section of size
40mmx18mm wall thickness 1.25mm. weight 0.417 kg./m, shutter
sideouter 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m,
shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. weight
0.469 kg/m; shutters mounted on nylon rollers with approved quality of
fixtures such as aluminium handles, tower bolts etc.; providing and fixing
Sqm 3723.00
5.5mm. thick plain glass for shutters fitted with rubber beading including
cutting to required length, joints mitred subdividing the frame, tenonned
and rivetted in the assembled frame to be stiffened with end clips at
corners, angles etc.; fixed to the walls, lintels, floor beams;cills, as the case
may be with necessary steel screws, raul plugs, or teak wood gatties
including cutting masonry or concrete and making good the original surface
using cement mortar; aluminium sections pretreated for removal of any
rust and coated with greasy materials for non adhesion of mortar and other
sticky materials; ( this coating should be cleaned after installation )
including cost of materials, fixtures, labour and HOM of machinery
7.12.2 complete
KSRB 7.12 as per specifications.
: Providing and fixing in position aluminium windows and
ventilators as per approved drawings with sliding shutters using four track
window frame of size 122.2x31.75mm. for bottom section 1.1mm thick,
weight 1.205 kg/m; sides and top sections 1.2 mm. thick weight 1.093
kg/m; shutter section comprising top and bottom section of size
40mmx18mm wall thickness 1.25mm. weight 0.417 kg./m, shutter
sideouter 40mmx18mm. wall thickness 1.25mm. weight 0.417 kg/m,
shutter interlock section 40mmx26.7mm wall thickness 1.1 mm. weight
0.469 kg/m; shutters mounted on nylon rollers with approved quality of
fixtures such as aluminium handles, tower bolts etc.; providing and fixing
Sqm 3903.00
5.5mm. thick plain glass for shutters fitted with rubber beading including
cutting to required length, joints mitred subdividing the frame, tenonned
and rivetted in the assembled frame to be stiffened with end clips at
corners, angles etc.; fixed to the walls, lintels, floor beams;cills, as the case
may be with necessary steel screws, raul plugs, or teak wood gatties
including cutting masonry or concrete and making good the original surface
using cement mortar; aluminium sections pretreated for removal of any
rust and coated with greasy materials for non adhesion of mortar and other
sticky materials; ( this coating should be cleaned after installation )
including cost of materials, fixtures, labour and HOM of machinery
7.13.1 complete7.13
KSRB as per
: specifications.
Providing and fixing aluminium casement windows,
combination of fixed glazing at top fully openable windows using Z sections
of 33mm, web thickness 4mm, weight 0.663 kg/m; central mullion section
59x33mm with web thickness 3mm section weight 1.123kg/m; the shutters
on aluminium hinges with approved quality of fixtures such as aluminium
tower bolts, handles, stays etc., providing and fixing 5.5mm plain glass for
shutters fitted with glazed clips 19mmx17.3mmx11mm. 0.9mm thick and
rubber beading, aluminium sections cutting to required length, joints
metered, subdividing the frame tennoned and rivetted, assembled frame to
be stiffened with end clips at corner, angles and fixed to wall, lintel beam,
Sqm 4776.00
floor;cill, as the case may be with necessary screws, rawl plugs, cutting
masonry or concrete and making good the orginal surface; aluminium
surface pretreated for removal of any rust and coated with greasy materials
for nonadherence of mortar or any other sticky materials; (coating removed
after instalation) and throughly cleaned free from dirt, rust etc., including
cost of materials, fixtures, labour and HOM of machinery complete as per
specifications.
using aluminium section anodized to 12 - 15 microns.

Page 22 of 375
7.13.2 KSRB 7.13 : Providing and fixing aluminium casement windows,
combination of fixed glazing at top fully openable windows using Z sections
of 33mm, web thickness 4mm, weight 0.663 kg/m; central mullion section
59x33mm with web thickness 3mm section weight 1.123kg/m; the shutters
on aluminium hinges with approved quality of fixtures such as aluminium
tower bolts, handles, stays etc., providing and fixing 5.5mm plain glass for
shutters fitted with glazed clips 19mmx17.3mmx11mm. 0.9mm thick and
rubber beading, aluminium sections cutting to required length, joints
metered, subdividing the frame tennoned and rivetted, assembled frame to
be stiffened with end clips at corner, angles and fixed to wall, lintel beam,
Sqm 4861.00
floor;cill, as the case may be with necessary screws, rawl plugs, cutting
masonry or concrete and making good the orginal surface; aluminium
surface pretreated for removal of any rust and coated with greasy materials
for nonadherence of mortar or any other sticky materials; (coating removed
after instalation) and throughly cleaned free from dirt, rust etc., including
cost of materials, fixtures, labour and HOM of machinery complete as per
specifications.
using aluminium section powdered coated to a minimum of 60-70 microns
with exterior durable pure polyester grade powder of approved quality.

Page No.36
7.14.1 KSRB 7.14 : Providing, fabricating, assembling and fixing in position
aluminium partitions using sections in combination of plain, single grove
and double grove as per requirements for the frames of overall size
101.6mm x 44.45mm, 3.18mm.thick having section weight, plain sections
2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683
kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm
1.7mm. thick section weight 0.483kg/m; bottom portions provided with
12mm. thick prelaminated sheet both side of approved colour lamination
exterior grade; aluminium sections of mat finish or glossy finish using
section, spacing of vertical member shall not exceed 0.6 m. c to c; sections
Sqm 4734.00
are cut to the required lengths, joints mitered and corners grinded
subdividing frames tennoned and rivetted to the frames, the assembled
frame should be stiffened with corner angles stripped and fixed with
screws, rawl plugs and teak wood gutties to R.C.C.columns or masonry on
sides, R.C.C. lintels or beams at top and floor at bottom, including cutting
chistling and making good with cement mortar to match the surface,
providing and fixing bottom panel filled with the materials to a height of
0.9m. from floor level; and 5.5mm. thick plain glass for middle portion viz.,
0.9m. to 2.13 m. and top panel with lower sections, the glass and panels
fitted with glazing clips of 19mmx17.3mm. with thickness of 0.9mm. weight
7.14.2 0.124kg/m;
KSRB 7.14 aluminium
: Providing,sections pre-treated
fabricating, for removal
assembling of any
and fixing in rust and
position
aluminium partitions using sections in combination of plain, single grove
and double grove as per requirements for the frames of overall size
101.6mm x 44.45mm, 3.18mm.thick having section weight, plain sections
2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683
kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm
1.7mm. thick section weight 0.483kg/m; bottom portions provided with
12mm. thick prelaminated sheet both side of approved colour lamination
exterior grade; aluminium sections of mat finish or glossy finish using
section, spacing of vertical member shall not exceed 0.6 m. c to c; sections
Sqm 4795.00
are cut to the required lengths, joints mitered and corners grinded
subdividing frames tennoned and rivetted to the frames, the assembled
frame should be stiffened with corner angles stripped and fixed with
screws, rawl plugs and teak wood gutties to R.C.C.columns or masonry on
sides, R.C.C. lintels or beams at top and floor at bottom, including cutting
chistling and making good with cement mortar to match the surface,
providing and fixing bottom panel filled with the materials to a height of
0.9m. from floor level; and 5.5mm. thick plain glass for middle portion viz.,
0.9m. to 2.13 m. and top panel with lower sections, the glass and panels
fitted with glazing clips of 19mmx17.3mm. with thickness of 0.9mm. weight
0.124kg/m; aluminium sections pre-treated
Page No. 37 for removal of any rust and

Page 23 of 375
7.15.1 KSRB 7.15 : Providing, fabricating, assembling and fixing in position
aluminium partitions using aluminium sections of mat finish or glassy
finish in combination of plain grove, single grove and double grove as per
requirements for the frames of overall size 63.5mm x 38.1mm. with
thickness of 2mm. having section weight, plain sections 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094kg/m, double grove thickness
1.9mm section weight 1.094kg/m and bottom member 114.3 mm. x
44.45mm. thickness 3.18mm. weight 2.646 kg/m; aluminium louvres
section of size 36.5mmx34.93mm 1.45mm. thick section weight
0.429kg/m; bottom portions provided with 12mm. thick prelaminated sheet
Sqm 3364.00
both sides of approved colour lamination exterior grade upto 0.9m height,
spacing of vertical member not exceeding 0.6 m. c to c; sections are cut to
the required lengths, joints mitered and corners grinded subdividing frames
tennoned and rivetted to the frames; the assembled frame stiffened with
corner angles, stripped and fixed with screws, rawl plugs and teak wood
gutties to R.C.C.columns on sides, R.C.C. lintels or beams at top and floor
at bottom, including cutting chistelling and making good with cement
mortar to match the surface; providing and fixing 5.5mm. thick plain glass
for middle portion viz., 0.9m. to 2.13 m. and top panel with louvres
sections; the glass and panels fitted withglazing clips of 19mmx17.3mm. of
7.15.2 thickness
KSRB 7.150.9mm. weight fabricating,
: Providing, 0.124kg/ m, aluminium
assembling andsections treated
fixing in for
position
aluminium partitions using aluminium sections of mat finish or glassy
finish in combination of plain grove, single grove and double grove as per
requirements for the frames of overall size 63.5mm x 38.1mm. with
thickness of 2mm. having section weight, plain sections 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094kg/m, double grove thickness
1.9mm section weight 1.094kg/m and bottom member 114.3 mm. x
44.45mm. thickness 3.18mm. weight 2.646 kg/m; aluminium louvres
section of size 36.5mmx34.93mm 1.45mm. thick section weight
0.429kg/m; bottom portions provided with 12mm. thick prelaminated sheet
Sqm 3432.00
both sides of approved colour lamination exterior grade upto 0.9m height,
spacing of vertical member not exceeding 0.6 m. c to c; sections are cut to
the required lengths, joints mitered and corners grinded subdividing frames
tennoned and rivetted to the frames; the assembled frame stiffened with
corner angles, stripped and fixed with screws, rawl plugs and teak wood
gutties to R.C.C.columns on sides, R.C.C. lintels or beams at top and floor
at bottom, including cutting chistelling and making good with cement
mortar to match the surface; providing and fixing 5.5mm. thick plain glass
for middle portion viz., 0.9m. to 2.13 m. and top panel with louvres
sections; the glass and panels fitted withglazing clips of 19mmx17.3mm. of
7.16.1 thickness
KSRB 7.160.9mm. weight fabricating,
: Providing, 0.124kg/ m, aluminium
assembling andsections treated
fixing in for
position
aluminium shutters to the existing door frame in the partition using
47.62x44.45mm section thickness 3.18mm, weight 1.505kg/m for vertical
frame; 47.62x44.45 thickness of 3mm, weight 1.42kg/m for top section,
49.91mmx44.45mm with wall thickness 3mm, weight 1.495kg/ m for
central rail; and 114.3mmx44.45mm thickness 3.18mm, weight 2.646kg/m
for bottom rail; aluminium sections and cut to length joint metred and
corners grinded, the bottom rail and top rail hinged or pivoted, opening
arrangements including providing and fixing standard approved
accessories, such as aluminium handles, tower bolts, lock, pivots: hinges
Sqm 3977.00
P.V.C. or rubber gasket, 12mm prelaminated sheets ( Novopan) exterior
grade of approved colour both sides same colour for bottom panel of
maximum height 0.90m and 5.5mm thick plain glass for top panel
( Novopan ) and glass fixed with glazed clips 19mmx17.3mmx11mm,
0.9mm thick, weight 0.124kg/m; aluminium sections treated for removal of
any rust and prevention of further rust formation, and coated with greasy
materials for non-adherance of mortars or any other sticky materials,
including cost of materials, fixtures, labour and HOM of machinery
complete as per specifications.
using aluminium section anodized to 12 - 15 microns.
7.16.2 KSRB 7.16 : Providing, fabricating, assembling and fixing in position
aluminium shutters to the existing door frame in the partition using
47.62x44.45mm section thickness 3.18mm, weight 1.505kg/m for vertical
frame; 47.62x44.45 thickness of 3mm, weight 1.42kg/m for top section,
49.91mmx44.45mm with wall thickness 3mm, weight 1.495kg/ m for
central rail; and 114.3mmx44.45mm thickness 3.18mm, weight 2.646kg/m
for bottom rail; aluminium sections and cut to length joint metred and
corners grinded, the bottom rail and top rail hinged or pivoted, opening
arrangements including providing and fixing standard approved
accessories, such as aluminium handles, tower bolts, lock, pivots: hinges
Sqm 4018.00
P.V.C. or rubber gasket, 12mm prelaminated sheets ( Novopan) exterior
grade of approved colour both sides same colour for bottom panel of
maximum height 0.90m and 5.5mm thick plain glass for top panel
( Novopan ) and glass fixed with glazed clips 19mmx17.3mmx11mm,
0.9mm thick, weight 0.124kg/m; aluminium sections treated for removal of
any rust and prevention of further rust formation, and coated with greasy
materials for non-adherance of mortars or any other sticky materials,
including cost of materials, fixtures, labour and HOM of machinery
complete as per specifications.
using aluminium section powdered coated to a minimum of 60-70 microns
with exterior durable pure polyester grade powder of approved quality.
Page 24 of 375
Page No. 38
7.17.1 KSRB 7.17 : Providing, fabricating, assembling and fixing in position
aluminium doors using following aluminium mat finish or glossy finish,
outer frame plain section 101.6x44.45mm thickness 3.18mm, section
weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm
thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm
thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45
thickness 3.18mm, section weight 2.646kg/m, door central section
49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing
clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m;
aluminium sections cut to length joint metred cornersgrinded, the shutters
Sqm 6131.00
pivoted opening arrangement with heavy duty aluminium alloy automatic
door closures floor mounted, providing and fixing standard approved
accessories, such as aluminium handle for full width or length, tower bolts,
lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top
and bottom panel; aluminium sections treated for removal of any rust and
prevention of further rust formation, and coated with greasy materials for
non-adherance of mortars or any other sticky materials; the assembled
frame fitted with the corner angles, strips and fitted with screws, rawl plugs
or teakwood gutties to R.C.C. columns or masonry on sides. beams and
flooring in bottom. including cutting, chistling and making good with
7.17.2 cement
KSRB 7.17mortar to match the
: Providing, surface; all
fabricating, the framesand
assembling throughly
fixing cleaned free
in position
aluminium doors using following aluminium mat finish or glossy finish,
outer frame plain section 101.6x44.45mm thickness 3.18mm, section
weight 2.404 kg/m, door shutters vertical section 44.62x44.45mm
thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm
thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45
thickness 3.18mm, section weight 2.646kg/m, door central section
49.91x44.45mm thickness 3.00mm, section weight 1.495 kg/m glazing
clips 19x17.3x11mm thickness 0.9mm section weight 0.124kg/m;
aluminium sections cut to length joint metred cornersgrinded, the shutters
Sqm 6220.00
pivoted opening arrangement with heavy duty aluminium alloy automatic
door closures floor mounted, providing and fixing standard approved
accessories, such as aluminium handle for full width or length, tower bolts,
lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain glass for top
and bottom panel; aluminium sections treated for removal of any rust and
prevention of further rust formation, and coated with greasy materials for
non-adherance of mortars or any other sticky materials; the assembled
frame fitted with the corner angles, strips and fitted with screws, rawl plugs
or teakwood gutties to R.C.C. columns or masonry on sides. beams and
flooring in bottom. including cutting, chistling and making good with
7.18 cement mortar
Providing to match
and fixing the surface;
of Aluminium all the frames
composite throughly
panel of cleaned
approved free
make and
colour for wall cladding for straight Brick/Rcc/stone walls &
coloumns/beams with necessary aluminium frame works at required level
made out of 50x25x3mm C section or equalent. The panel should consist of
2.5 mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminium sheet making a total panel thickness of 3mm. The
surfaces will be finished with PVDF based coating on topsides and service
coating on reverse sides would be in polyester paint. The system shall be Sqm 3940.00
fixed using GI brackets, aluminium L cleats and stainless steel bolts and
nuts complete with spring washer and cap nuts and all other necessary
accessories, sealing shall be done using weather sealant of Dow Corning
789 with necessary rods etc., complete.

7.19 Providing and fixing of Aluminium composite panel of approved make and
colour for wall cladding for curved Brick/Rcc/stone walls &
coloumns/beams with necessary aluminium frame works at required level
made out of 50x25x3mm C section or equalent. The panel should consist of
2.5 mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminium sheet making a total panel thickness of 3mm. The
surfaces will be finished with PVDF based coating on topsides and service
coating on reverse sides would be in polyester paint. The system shall be Sqm 4400.00
fixed using GI brackets, aluminium L cleats and stainless steel bolts and
nuts complete with spring washer and cap nuts and all other necessary
accessories, sealing shall be done using weather sealant necessary rods
etc., complete.

Page No. 39

Page 25 of 375
7.20 Providing, fabricating and fixing of stick type structural glazing using
Alluminium Extrusions of 63.5 mm x 58.00 mmx 2.25 mm of 1.73 kgs/ mtr
for vertical and Horizontal members and 63.5 mm x 38.1 x 1.33 mm of
0.759 kg/Mtr, as outer frame with Electro Anodized Paint coated block
finishing, using 6mm thick imported glass reflective hard coatedocean blue
raw glass with all necessary accesories like ultra glass Silicon sealant of Sqm 6653.00
Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, 6mm
thick M.S. angle 50mm x 150mm x 6mm M.S. Galvanized L Brackets,
structural sealent setting clocks, fasteners, wall connection etc., complete.

7.21.1 "Providing fusion bonded epoxy coating not less than 175 microns
thickness and upto 300 microns to reinforcement of all diameters as per IS:
13620-1993 including testing of coating at plant. The rate is inclusive of
cost on account of careful handling, PVC coated binding wire instead of GI
Binding wire, touch up material supplied by coating agency, repair work, Tonne 10535.00
loading, unloading and straightening of bent rods etc., complete as per
specification and as directed by the Engineer in charge. (Inclusive of all
taxes but excluding transportation charges)
For 10mm to 16mm dia bars

7.21.2 "Providing fusion bonded epoxy coating not less than 175 microns
thickness and upto 300 microns to reinforcement of all diameters as per IS:
13620-1993 including testing of coating at plant. The rate is inclusive of
cost on account of careful handling, PVC coated binding wire instead of GI
Binding wire, touch up material supplied by coating agency, repair work, Tonne 8380.00
loading, unloading and straightening of bent rods etc., complete as per
specification and as directed by the Engineer in charge. (Inclusive of all
taxes but excluding transportation charges)
For 20mm to 32mm dia bars

7.22.1 Providing , fabricating, assembling and fixing in position aluminium


partition using 101.60mm x 44.45mm x 3.18mm aluminium, mat finish or
glossy finish , anodized sections combination of plain , single groove and
double groove members should not exceed 0.60mc/c and bottom member of
required lengths, joints mitred and corner grinded sub dividing assembled
frame should be stiffened with corner angles. Stripped and fixed with
screws rawl plug and teakwood guttas to RCC column or masonry on sides.
RCC lintels or beams at top and mosaic floor at bottom; including cutting
chistelling and making good with cement mortar to match the
surface .Providing and fixing 12mm.thick prelaminated sheet (Ecoboard –
Sqm 2500.00
exterior grade )of approved colour for bottom panel of maximum height
0.9m, and 5.50 mm thick plain or pin headed glass for middle panel and
top panel with glazing clips pf 19.05mm.x17.30mm.1.00mm. All the
aluminium sections used should be treated for removal of any rust and
prevention of further rust formation and coated with greasy materials for
non adherence of mortar or any other sticky materials: The vertical
members should be embedded in the flooring by making suitable size holes
and fixing with cement mortar. All the frame should be thoroughly cleaned
free from rust , scale or dirt. work should be carried out as per direction of
engineer-in-charge of the work with all lead and lift as per chief Architect’s
drawing etc., complete to a degree of perfection.
Page No. 40
7.22.2 Providing , fabricating, assembling and fixing in position aluminium
partition using 101.60mm x 44.45mm x 3.18mm aluminium, mat finish or
glossy finish , anodized sections combination of plain , single groove and
double groove members should not exceed 0.60mc/c and bottom member of
required lengths, joints mitred and corner grinded sub dividing assembled
frame should be stiffened with corner angles. Stripped and fixed with
screws rawl plug and teakwood guttas to RCC column or masonry on sides.
RCC lintels or beams at top and mosaic floor at bottom; including cutting
chistelling and making good with cement mortar to match the
surface .Providing and fixing 12mm.thick prelaminated sheet (Ecoboard –
Sqm 2600.00
exterior grade )of approved colour for bottom panel of maximum height
0.9m, and 5.50 mm thick plain or pin headed glass for middle panel and
top panel with glazing clips pf 19.05mm.x17.30mm.1.00mm. All the
aluminium sections used should be treated for removal of any rust and
prevention of further rust formation and coated with greasy materials for
non adherence of mortar or any other sticky materials: The vertical
members should be embedded in the flooring by making suitable size holes
and fixing with cement mortar. All the frame should be thoroughly cleaned
free from rust , scale or dirt. work should be carried out as per direction of
engineer-in-charge of the work with all lead and lift as per chief Architect’s
drawing etc., complete to a degree of perfection.

Page 26 of 375
7.23 Providing and fixing door frame with or without ventilator made out of cold
rolled steel section of thickness 1.25mm formed into section of 60mm x
105mm welded to form a rectangular door conforming to IS 513-1973 and
phosphated and painted and with one coat of red oxideprimer, two coat of
approved enamel paints the frame work with 4nos. of hold fast of size 200 x
25 x 4mm fixed in cement concrete 1:3 :6 of 20mm down size jelly and
4nos. of ISI marked hinges 125mm long welded to the frame and fixed with
shutter made out of Honne wood styles and rails of 30mm thick with panels Sqm 2000.00
of 12mm thick ‘Ecoboard’ Plain Particle Board of exterior grade conforming
to IS- 3087 excluding the cost of fixtures but including labour charges for
fixing of fixtures.. The hollow portion of the frame to be filled with c.c1:2:4
of 20mm down size jelly.

7.24.1.a "Providing and fixing cold rolled prepainted steel windows of IS standards,
made out of 0.6mm thick deep drawing quality galvanised on both sides
120gms/sq.mtr. Primer coat upto 5 microns with thermosetting epoxy resin
and finish painted with a polyester based paint 20 microns thick. The size
of profiles is approximately 46 x 52mm for external frames, 46x46mm
section for shutters, 46x70mm section for centre mullion/transom and
18x31mm section is for fixing glasses. The section should be cut to length
joint mitred and assembling by means of corner brackets made out of cold
rolled cold annealed strips of 1.2mm thick duly galvanised and fixed with
nickle plated self taping screws.The shutters are provided with approved Sqm 4400.00
quality of fixtures like handles made out of zamac alloy die cast and powder
coated, receiver made out of glass filled nylone and hinges made out of
CRCA powder coated. 4mm thick glass should be fixed with EPDM gaskets.
Guard bars fabricated out of 10mm square bright bars shall be fixed
horizontally at 125mm C/C by rivetting to the external frame. The above
frames are fixed to the concrete / masonry walls by means of self expanding
screws.” with 4mm float glass without gaurd bars

7.24.1.b "Providing and fixing cold rolled prepainted steel windows of IS standards,
made out of 0.6mm thick deep drawing quality galvanised on both sides
120gms/sq.mtr. Primer coat upto 5 microns with thermosetting epoxy resin
and finish painted with a polyester based paint 20 microns thick. The size
of profiles is approximately 46 x 52mm for external frames, 46x46mm
section for shutters, 46x70mm section for centre mullion/transom and
18x31mm section is for fixing glasses. The section should be cut to length
joint mitred and assembling by means of corner brackets made out of cold
rolled cold annealed strips of 1.2mm thick duly galvanised and fixed with
nickle plated self taping screws.The shutters are provided with approved Sqm 4500.00
quality of fixtures like handles made out of zamac alloy die cast and powder
coated, receiver made out of glass filled nylone and hinges made out of
CRCA powder coated. 4mm thick glass should be fixed with EPDM gaskets.
Guard bars fabricated out of 10mm square bright bars shall be fixed
horizontally at 125mm C/C by rivetting to the external frame. The above
frames are fixed to the concrete / masonry walls by means of self expanding
screws.” with 4mm tinted glass without gaurd bars

7.24.1.c "Providing and fixing cold rolled prepainted steel windows of IS standards,
made out of 0.6mm thick deep drawing quality galvanised on both sides
120gms/sq.mtr. Primer coat upto 5 microns with thermosetting epoxy resin
and finish painted with a polyester based paint 20 microns thick. The size
of profiles is approximately 46 x 52mm for external frames, 46x46mm
section for shutters, 46x70mm section for centre mullion/transom and
18x31mm section is for fixing glasses. The section should be cut to length
joint mitred and assembling by means of corner brackets made out of cold
rolled cold annealed strips of 1.2mm thick duly galvanised and fixed with
nickle plated self taping screws.The shutters are provided with approved Sqm 5250.00
quality of fixtures like handles made out of zamac alloy die cast and powder
coated, receiver made out of glass filled nylone and hinges made out of
CRCA powder coated. 4mm thick glass should be fixed with EPDM gaskets.
Guard bars fabricated out of 10mm square bright bars shall be fixed
horizontally at 125mm C/C by rivetting to the external frame. The above
frames are fixed to the concrete / masonry walls by means of self expanding
screws.” with 4mm float glass with gaurd bars

Page 27 of 375
7.24.1.d "Providing and fixing cold rolled prepainted steel windows of IS standards,
made out of 0.6mm thick deep drawing quality galvanised on both sides
120gms/sq.mtr. Primer coat upto 5 microns with thermosetting epoxy resin
and finish painted with a polyester based paint 20 microns thick. The size
of profiles is approximately 46 x 52mm for external frames, 46x46mm
section for shutters, 46x70mm section for centre mullion/transom and
18x31mm section is for fixing glasses. The section should be cut to length
joint mitred and assembling by means of corner brackets made out of cold
rolled cold annealed strips of 1.2mm thick duly galvanised and fixed with
nickle plated self taping screws.The shutters are provided with approved Sqm 5350.00
quality of fixtures like handles made out of zamac alloy die cast and powder
coated, receiver made out of glass filled nylone and hinges made out of
CRCA powder coated. 4mm thick glass should be fixed with EPDM gaskets.
Guard bars fabricated out of 10mm square bright bars shall be fixed
horizontally at 125mm C/C by rivetting to the external frame. The above
frames are fixed to the concrete / masonry walls by means of self expanding
screws.” with 4mm tinted glass with gaurd bars

7.25 Providing and fixing cold rolled prepainted steel partitions of IS standards,
made out of 0.6mm of deep drawing quality galvanised on both sides
120gms/Sq.mtr. Primer coated upto 5 microns with thermosetting epoxy
resin and finish painted with a polyester based paint 20 microns thick. The
size of profiles is 46X52mm for external frame, section for mullion or
transom is of size 46x70mm and section for fixing glass/board is of
18x31mm. The section should be cut to length joint mitred and assembling
by means of corner brackets made out of cold rolled cold annealed strips of Sqm 2500.00
1.2mm thick duly galvanised and fixed with nickel plated self taping
screws. 5mm thick glass should be fixed with EPDM gaskets. 10mm thick
prelaminated particle board shall be fixed with the help of the clipping
bead. The above frames are fixed to the concrete / masonry walls and floors
by means of self expanding screws.

Page No. 41
7.26 Supplying and fixing pressed steel door frames size 125x65 mm
manufactured from 1.25mm thick carbon steel or imported steel strips with
mitred joints of 900 for door openings and shutters made out of seasoned
Honne wood, styles of 30 mm, thick with lock rail of 160 mm, width, top
and side rails of 100 mm. width and bottom rails of 250 mm width and
panel filling with 12mm thick particle board of exterior grade bonded with
phenol formal dehide resin and the shutter shall be rot proof, vermin proof,
heat resistant guaranteed against shrinkage, warpage and such other
defects for a period of 3 years. This shall be as per approved drawings, Sqm 3210.00
specification and direction including cost of conveyance, manufacturing,
painting with enamel paint 2 coats over primer coat, cost of labour for all
items of work, machinery, equipment and all other incidental charges with
all lead, lift, loading and unloading etc., complete. The Hollow portion of the
frame to be filled with cement concrete 1:2:4.

7.27 "Supplying and fixing pressed steel window frame of size 100 x 50mm
manufactured from 1.25 mm thick carbon steel or imported steel strips
with neat mitred joints at 900degree for window openings and shall be
suitable to fix M.S. grills as per design and drawings using 12mm dia rods
at 100mm Centre to Centre horizontally and two members of M.S flats of
6mmx40mm size at 150mm apart, welded into a frame of 6mmx40mm size
M.S. flats with 16mm size lugs, and 8 Nos. of 100mm size hinges, 4 Nos of
Butt Stay pins and 4 Nos. Tower bolts and shutters half panelled and hallf
glazed with shutters made out of seasoned honne wood, styles of 30mm
thick and 100mm width and rails of 30mm thick and 100mm width and Sqm 3550.00
using 4mm thick pin headed glass and panel, filling with 12mm thick
particle board of exterior grade bonded with phenol formal dehide resin and
the shutter shall be rot proof vermin proof, heat resistant guaranteed
against shrinkage, warp age and such other defects for a period of 3
years.This shall be as per approved drawing, specification and direction
including cost of conveyance, manufacturing painting with 2 coats enamel
paint over one coat of primer, cost of labour for all items of work,
machinery, equipment and all other incidental charges with all lead, lift
loading and unloading etc., complete. The Hollow portion of the frame to be
7.28 Providing electric welding using carbon electrodes including cost of welding
machine, power charges, welding rods, and labour charges for welding etc., cm 3.00
complete as per specification.
Page No. 42

Page 28 of 375
7.29 Fabricating, supplying and erecting M.S. TubularTruss of span upto 10m.
The bottom and top member is provided with 50x50x6mm double equal
angles, welded back to back and in between top and bottom line, in areas of
mid section is provided with 50x50x6mm equal single angle for vertical and
inclined members and at supporting ends 40x40x5mm single angle is
provided. All the members are welded together with 6mm gusset plate as
per Drawing. The entire truss is anchored in RCC column by using 4 Nos.
of M.S. anchor bolts at each support, with 10mm thick base plate and shoe
plate.The work includes cutting, straightening, placing in position of M.S Kgs 111.00
angle and wleding wherever necessary, and applying one coat of red oxide
primer coat to all themembers including cost of all materials, labour
charges, and hire charges of machineries for cutting, welding, grinding and
erection equipments, with all lead and lift, transportation, etc., complete as
per specification. (Page No. 40 Item No. 7.29 of CSR 2015-16).

7.30 Fabricating, supplying & erecting M.S. angular Truss of span upto 10m.
The bottom & top member is provided with 50x50x6mm double equal
angles, welded back to back and in between top & bottom line, in areas of
mid section is provided with 50x50x6mm equal single angle for vertical and
inclined members and at supporting ends 40x40x5mm single angle is
provided. All the members are welded together with 6mm gusset plate as
per Drawing No.CBS/ SD/K-Mantap/9/MND/97. The entire truss is
anchored in RCC column by using 4 Nos. of M.S. anchor bolts at each
support, with 10mm thick base plate and shoe plate.The work includes Kgs 128.00
cutting, straightening, placing in position of M.S angle and wleding
wherever necessary, and applying one coat of red oxide primer coat to all
the members including cost of all materials, labour charges, & hire charges
of machineries for cutting, welding, grinding & erection equipments, etc.,
complete as per specification. (Page No. 40 Item No. 7.30 of CSR 2015-16).

7.31 Fabricating, providing and erecting in poiston of M S Ornamental security


Grill Gate without hot dip using 75 x 12mm M S Flat for alround frame
work with verticals at the centre and horizontal centere support M S Square
of 20 x20 mm of different heights as shown in the drawing are to be fixed at
16 cms C/C for suqare bars of full height and at 8cms C / C for bottom
rods providg ornamental C I Designers at the botom and C I arrows inthe
midle and top. The entire frame work is to be fixed by means of expansion
bolts to the brick pillars with necesary drillling holes. the work includes
providng two coats of enamel painting over one coatr of red lead ready mix Kgs 132.00
primer coat etc complete cost of all labour, painting, erection charges using
hoist pulleycranes with all lead and lift, loading, transporting and
unloading using hoist pulley cranes, scaffolding charges and all other
incidental charges required for successful completion fo the work as per
specification and drawings

7.32 Fabricating, providing and erecting in poiston of Hot dip galvanised


M.S.Ornamental security Grill Gate using 75 x 12mm M S Flat for alround
frame work with verticals at the centre and horizontal centere support M S
Square of 20 x20 mm of different heights as shown in the drawing are to be
fixed at 16 cms C/C for suqare bars of full height and at 8cms C / C for
bottom rods providg ornamental C I Designers at the botom and C I arrows
inthe midle and top. The entire frame work is to be fixed by means of Kgs 151.00
expansion bolts to the brick pillars with necesary drillling holes. the work
includes providng two coats of enamel painting over one coat of red lead
ready mix primer coat etc complete cost of all labour, painting, erection
charges using hoist pulleycranes etc as per specification and drawings.

Page No. 43
7.33 Fabricating, providing and erecting in poiston of M S Ornamental security
Grill without hot dip using 75 x 12mm M S Flat for alround frame work
with verticals at the centre and horizontal centere support M S Square of 20
x20 mm of different heights as shown in the drawing are to be fixed at 16
cms C/C for suqare bars of full height and at 8cms C / C for bottom rods
providg ornamental C I Designers at thebotom and C I arrows inthe midle
and top. The entire frame work is to be fixed by means of expansion bolts to Kgs 149.00
the brick pillars with necesary drillling holes. the work includes providng
two coats of enamel painting over one coatr of red lead ready mix primer
coat etc complete cost of all labour, painting, erection charges using hoist
pulleycranes etc as per specification and drawings.

Page 29 of 375
7.34 Fabricating, providing and erecting in poiston of Hot dip galvanised M S
Ornamental security Grill using 75 x 12mm M S Flat for alround frame
work with verticals at the centre and horizontal centere support M S Square
of 20 x20 mm of different heights as shown in the drawing are to be fixed at
16 cms C/C for suqare bars of full height and at 8cms C / C for bottom
rods providg ornamental C I Designers at the botom and C I arrows inthe
midle and top. The entire frame work is to be fixed by means of expansion
bolts to the brick pillars with necesary drillling holes. the work includes
providng two coats of enamel painting over one coatr of red lead ready mix Kgs 179.00
primer coat etc complete cost of all labour, painting, erection charges using
hoist pulleycranes with all lead and lift, loading, transporting and
unloading using hoist pulley cranes, scaffolding charges and all other
incidental charges required for successful completion fo the work as per
specification and drawings,

7.35 Providing and fixing M.S. Hand railing for Balcony with 50mm dia. M.S.
hollow pipe of 14 gauge, welded to 20mmx20mm M.S. square rod placed
vertically, spaced at 100mm at regular intervals of 600mm. These vertical
rods laterally tied to 3 horizontal rods spaced at equal interval. These
assembly is fixed to concrete by using expansion bolts and welding the
same to reinforcement bars and making good the surface. All the joints and
Sqm 2840.00
sections hould be cut to length, welded and grinded wherever necessary
etc., complete . The work includes cost of all materials, labour charges for
all items of work, hire charges for welding, cutting and grinding equipment,
and electricity charges, etc., complete as per specification and drawing.

7.36 Providing and fixing M.S.Grill over existing compound wall as per Chief
Architect drawing No. 12686, using 16mm x 16mm M.S.Square rod at
150mm c/c spacing and 6mm x 40mm M.S. flats at horizontal and 6mm
x12mm M.S. flat for ornamental design and providing shop edge design at
the vertex of every vertical rods, including welding, grinding wherever
necessary. All the steel surface should be thoroughly cleaned free of rust
Sqm 5369.00
and painted with anti corrosive paint (shop paint) etc., complete. The work
includes cost of all materials, labour charges for all items of work, hire
charges for welding, cutting and grinding equipment, and electricity
charges, etc., complete as per specification.

Page No. 44
7.37 Providing and fixing M.S. Gate as per Chief Architect Drawing, using 50mm
x 50mm 14 guage M.S. hollow pipe frame work bent to ornamental shape
as shown in the drawing and 35mm x 6mm and 16 x 16mm Square rods for
verticals alternatively spaced at 4cms c/c in two halves and 40mmx6mm
M.S. flats for horizontal member and at the top cast iron spikes are
provided at alternate vertical members asshown in the drawing etc.,
complete. All the steel surface should be thoroughly cleaned free of rust and
painted with anti corrosive paint (shop paint) etc., complete. The work Sqm 3012.00
includes cost of all materials, labour charges for all items of work, hire
charges for welding, cutting and grinding equipment, and electricity
charges, with lead and lift, loading and unloading charges, etc., complete as
per specifiocation. (P. No. 43 / I. No. 7.37 of CSR 2015-16)

7.38 Providing and fixing Stainless steel staircase raling as per Chief Architect
Drawing No. 11520/ HRSC with hand rail 50mm dia 16 guage hollow pipe
welded to vertical hollow 50mm dia pipe of 16 guage, stainless steel vertical
pipe spaced at 1.20m regular intervals, and 5 Nos of 25mm dia. Stainless
steel hollow horizontal pipe are welded to vertical 50mm dia hollow pipe.
The entire assembly is fixed to staircase concrete by using expansion bolts Sqm 6021.00
by drilling concrete etc., complete including cost of materials, labour, HOM
of machineries and electrical charges, etc., complete as per specifications.
(P. No. 43 / I. No. 7.38 of CSR 2015-16)

Page 30 of 375
7.39 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes
for Ramps or Staircase are made out of stainless steel hallow pipes, using
50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by
drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of
Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally
for 2-rows top, one pipes are fixed with vertical pipes another one are fixed
with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top
measure @ equal intervals including cutting, welding, bending wherever
necessary with suitable caps @ tops, bottoms & corners finishing with Sqm 5378.00
mat / shining etc., complete including cost and conveyance of all materials,
labour for all items of work, HOM of equipment with all lead and lift,
loading and unloading, transportation charges and all other incidental
charges etc., complete as per specification and directions of the Engineer-
in-charge of the work. Ramps or Staircase for physically challenged. (P. No.
43 / I. No. 7.39 of CSR 2015-16)

Note :
1.KSRB 7-14 and KSRB 7-15 Door Opening shall only be deleted from the
over all measurements and balance area shall only be considered for
payment.
2.lift charges : The above are applicable for Ground and basement floors
only Add an additional rates of Rs. 6.00/sqm per floor above or below

Page No. 45

8.0 8.ROOFING
8.1 KSRB 8.1 : Providing and fixing in position stone slab roofing 10 to 12 cms
thick laid to line and level over wooden rafters or R.C.C. battens, pointing
exposed joints with cement mortar 1:4 including cost of materials, labour,
curing complete as per specifications. ( wooden rafters and R.C.C. battens Sqm 1158.00
to be paid seperately ) Specification No. KBS

8.2 KSRB 8.2 : Providing and fixing in position black cuddapah slab /
Shahabad slab / Thandur blue slab 4 cms thick for roofing laid to line and
level over wooden rafters or R.C.C. battens pointing exposed joints with
cement mortar 1:4 including cost of materials, labour, curing complete as Sqm 636.00
per specifications. (wooden rafters and R.C.C. battens to be paid
seperately )

8.3 KSRB 8.3-1 : Providing and laying to required line and slope roofing with
corrugated asbestos cement sheet 6mm. thick fixed with galvanised iron J
or L hooks, bolts and nuts 8mm. dia C.I plain and bitumen washers over
the existing purlins, rafters and trusses including cost of materials, labour, Sqm 346.00
complete as per specifications. Specification No. KBS 8.5 (P.No. 46, I.No.
8.3 of PWD SR 2015-16)

8.4 KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement :
15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid
to slope compacting, including cost of materials, labour, curing complete as cum 1995.00
per specifications.
8.5 KSRB 8.6-1 : Providing and fixing on wall surface cast iron rain down water
pipes 75mm dia including filling the joints with spun yarn soaked in neat
cement slurry 1:2 with necessary specials like shoes, bends and offsets m 990.00
fixed with iron clamps, wall plugs, screws, including cost of materials,
labour, complete as per specifications.
8.6 KSRB 8.3-2 : Providing and laying to required line and slope roofing with
semi-corrugated ( Trafford ) asbestos cement sheet 6mm. thick fixed with
galvanised iron J or L hooks, bolts and nuts 8mm. dia C.I plain and
bitumen washers, over the existing purlins, rafters and trusses including Sqm 374.00
cost of materials, labour, complete as per specifications.

8.7 KSRB 8.3-3 Extra for A.C. sheet corrugated / semi-corrugated sheet roofing
Sqm 15.00
with vertical sheeting to a pitch exceeding 60 degrees
8.8 KSRB 8.3-4 : Providing and fixing ridges, hips with asbestos cement sheet
roofing with G.I. J or L hooks, bolts and nuts 8mm. dia G.I.plain and
bitumen washers, serrated or plain wings, adjustable ridges, including cost m 300.00
of materials, labour, complete as per specifications.
8.9 KSRB 8.3-5 : Providing and fixing northlight adjustable ridges, hips with
asbestos cement sheet roofing with G.I. J or L hooks, bolts and nuts 8mm.
dia G.I.plain and bitumen washers, serrated or plain wings, adjustable m 211.00
ridges, including cost of materials, labour, complete as per specifications.

Page No. 48

Page 31 of 375
8.10 KSRB 8.4-1 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips, teak wood reepers of
size 50x25mm and pointed with cement mortar 1:4 over the existing rafters
including cost of materials, labour, curing complete as per specifications. Sqm 1068.00
Specification No. KBS 8.17. (P.No. 47, I.No. 8.10 of PWD SR 2015-16)

8.11 KSRB 8.4-2 :Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips,nandi wood reepers of
size 50x25mm and pointed with cement mortar 1:4 over the existing rafters Sqm 796.00
including cost of materials, labour, curing complete as per specifications.
Specification No. KBS 8.17
8.12 KSRB 8.4-3 : Providing and fixing Mangalore tile roofing using first class
tiles with necessary special tiles for ridges and hips,jungle wood reepers of
size 50x25mm and pointed with cement mortar 1:4 over the existing rafters Sqm 661.00
including cost of materials, labour, curing complete as per specifications.
Specification No. KBS 8.17
8.14 KSRB 8.6-3 : Providing and fixing on wall surface asbestos cement rain
down water pipes 75mm dia including filling the joints with spun yarn
soaked in neat cement slurry 1:2 with necessary specials like shoes, bends
and offsets fixed with iron clamps, wall plugs, screws, including cost of m 384.00
materials, labour, curing complete as per specifications. Specification No.
KBS 8.27, 8.28

8.15 KSRB 8.6-4 : Providing and fixing on wall surface asbestos cement rain
down water pipes 100 mm dia including filling the joints with spun yarn
soaked in neat cement slurry 1:2 with necessary specials like shoes, bends
and offsets fixed with iron clamps, wall plugs, screws, including cost of m 419.00
materials, labour, curing complete as per specifications. Specification No.
KBS 8.27, 8.28

8.16 KSRB 8.6-5 : Providing and fixing on wall surface 2.5 kg / sq.cm H.D.P.E.
rain down water pipes 90 mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps, wall m 365.00
plugs, screws, including cost of materials, labour, curing complete as per
specifications.
8.17 KSRB 8.6-6 : Providing and fixing on wall surface 2.5kg / sq.cm H.D.P.E.
rain down water pipes 110mm outer dia approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps, wall m 432.00
plugs, screws, including cost of materials, labour, curing complete as per
specifications.
8.18 KSRB 8.6-7 : Providing and fixing on wall surface 4.0 kg / sq.cm H.D.P.E.
rain down water pipes 90 mm outer dia. approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps, wall m 391.00
plugs, screws, including cost of materials, labour, complete as per
specifications.
8.19 KSRB 8.6-8 : Providing and fixing on wall surface. 40 kg / sq.cm H.D.P.E.
rain down water pipes 110mm outer dia. approved make and brand with
necessary specials like shoes, bends and offsets fixed with iron clamps, wall m 512.00
plugs, screws, including cost of materials, labour, complete as per
specifications. (P.No. 47/ I.No. 8.19 of CSR 2015-16)
8.20 KSRB 8.7-1 :Providing and fixing in position 10mm thick plaster of paris
(Gypsum anhydrous ) for ceiling flat surface upto a height of 5 m above
floor level over aluminium 25mm / 6mm with 10mm gap in between and
reinforced with rabbit wire mesh fixed to metal frames including cost of Sqm 1327.00
materials, labour, curing complete as per specifications. (P.No. 47/ I.No.
8.20 of CSR 2015-16)

8.21 KSRB 8.7-2 : Providing and fixing in position 10mm thick plaster of paris
(Gypsum anhydrous ) for ceiling curved surface upto a height of 5 m above
floor level over aluminium strips 25mm / 6mm with 10mm gap in between
and reinforced with rabbit wire mesh fixed to meatal frames including cost Sqm 1479.00
of materials, labour, curing complete as per specifications.

Page No. 49
8.22 KSRB 8.7-3 : Extra over item No. 8.7-1 and 8.7-2 for any sunk or raised
Sqm 596.00
moulded design plaster of paris ( Gypsum anhydrous ) ceiling
8.23 KSRB 8.7-4 : Extra over item No. 8.7-1 and 8.7-2 for providing plaster of
Sqm/m 161.00
paris (Gypsum anhydrous ) ceiling above 5 m height from floor level
8.24 KSRB 8.7-5 : Providing and fixing in position 12mm thick plaster of paris
(Gypsum anhydrous ) for ceiling flat surface with ceiling tiles upto a height
of 5 m above floor level over wooden frames and rendered smooth with
plaster of paris (frame work to be measured and paid for seperately ) Sqm 1167.00
including cost of materials, labour, curing complete as per specifications.

Page 32 of 375
8.25 KSRB 8.7-6 : Extra over item No. 8.7-5 for providing plaster of paris
Sqm/m 72.00
(Gypsum anhydrous ) ceiling tiles above 5 m height from floor level
8.26 Providing top layer with 12mm thick silica latex plaster with smooth
Sqm 345.00
finishing on top surface. (P.No. 48, I.No. 8.26 of PWD SR 2015-16)
8.27 Providing and fixing 6mm Bronze Multi wall poly carbonate sheet for
Tubular structure. The work including cost of all materials, labour charges,
and hire charges of machineries for cutting, welding, grinding and erection Sqm 3126.00
equipments, complete as per specification.
8.28 Providing and fixing 15 mm thick densified regular edged eco friendly light
weight calcium silicate False ceiling tiles of approved texture
spintone/cosmos/Hexa or equivalent of size 595X595 mm in true
horizontal level suspended on inter locking metal grid of hot dipped
galvanized steel sections (galvanizing @ 120 grams per sqm including both
sides) consisting of main T runner suitably spaced at joints to get required
length and of size 24 X 38 mm made from 0.33 mm thick (minimum) sheet,
spaced 1200 mm centre to centre, and cross T of size 24 X 28 mm made
out of 0.33 mm (minimum) sheet, 1200 mm long spaced between main T at
600 mm centre to centre to form a grid of 1200 X 600 mm and secondary Sqm 1504.00
cross T of length 600 mm and size 24 X 28 mm made of 0.33 mm thick
(minimum) sheet to be inter locked at middle of the 1200X600 mm panel to
form grid of size 600X600 mm resting on periphery walls / partitions on a
Perimeter wall angle precioated steel of size 24X24X3000 mm made of 0.40
mm thick with 25 mm long dry wall screwes at 230 mm intervals and laying
15 mm thick densifed edges calcium silicate ceiling tiles of approved texture
(Spintone / Cosmos) in the grid including cutting / making opening for
services like diffusers, grills, light fittings, fixtures, smoke detectors etc.,
wherever required, Main T runners ti be suspended from ceiling using G I
Page No. 50
8.29 Providing and fixing of pre pigmented extruded orange cement roof tiles of
size 420mm x 330mm with necessary specials such as Ridges, Barges and
Nails etc. including cast of providing PVC (6.00kgs/sq cm) gutters of min 6”
radius and down water pipes of 4” dia as per the roof design on EXISTING Sqm 721.00
MS/WOODEN ROOF or TRUSS. Including cost of materials, scaffoldings,
labour etc., compelte as per specifications.

8.30 Providing and fixing of pre pigmented extruded orange cement roof tiles of
size 420mm x 330mm with necessary specials such as Ridges, Barges and
Nails etc., including cost of providing PVC (6.00kgs/ sqcm) gutters of min
6” radius and down water pipes of 4” dia as per roof design on EXISTING Sqm 685.00
CONCRETE SLOPING ROOF SLAB. Including cost of mortar band, all
materials labour as per specifications.

8.31.1 Providing and laying non - asbestos high impact ploypropylene reinforced
corrugated cement roofing sheet reinforced with natural Grey colour and
with a blend of strong factory made fibre as per IS:14871 and IS:9933:1995
(E) roofing upto any pitch and fixing with polymer coated J or L hooks, bolts
and nuts 8mm dia, G I plain and bitumen washers or with self drilling
fastener and EPDM washers ete. complete but excluding the cost of purlins, Sqm 543.00
refters and trusses. including cutting to size and shape of corrugated sheets
wherever required. and cost of materials, labour, complete as per
specifications.

8.31.2 Providing and laying non - asbestos high impact ploypropylene reinforced
corrugated cement roofing sheet reinforced with Other colours and with a
blend of strong factory made fibre as per IS:14871 and IS:9933:1995 (E)
roofing upto any pitch and fixing with polymer coated J or L hooks, bolts
and nuts 8mm dia, G I plain and bitumen washers or with self drilling Sqm 590.00
fastener and EPDM washers ete. complete but excluding the cost of purlins,
refters and trusses. including cutting to size and shape of corrugated sheets
wherever required. and cost of materials, labour, complete as per
specifications.

Page No. 51

9.0 9.WOOD WORK


9.1 KSRB 9-1 :Labour for providing Teak wood wrought and putup for purlins,
common rafters and similar work including cost of labour, HOM of
machineries complete as per specifications. Specification No. KBS 9.4 cum 4987.00

9.2 KSRB 9-2.1 :Providing Honne wood wrought and putup for purlins,
common rafters and similar work including cost of materials, labour, HOM
of machineries complete as per specifications. Specification No. KBS 9.27 cum 86340.00

9.3 KSRB 9-2.2 :Providing Mathi / Nandi wood wrought and putup for purlins,
common rafters and similar work including cost of materials, labour, HOM
of machineries complete as per specifications. Specification No. KBS 9.27 cum 71932.00

Page 33 of 375
9.4 KSRB 9-2.3 :Providing Sal wood wrought and putup for purlins, common
rafters and similar work including cost of materials, labour, HOM of
machineries complete as per specifications. Specification No. KBS 9.27 cum 59284.00

9.5 KSRB 9-2.4 :Providing Jungle wood such as Nerale, Neem wrought and
putup for purlins, common rafters and similar work including cost of
materials, labour, HOM of machineries complete as per specifications. cum 42237.00
Specification No. KBS 9.27
9.10 KSRB 9.4-1 : Providing Teak wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves ( excluding cost of cement concrete and
side clamps ), but including cost of materials, labour, HOM of machineries cum 182079.00
complete as per specifications. Specification No. KBS 9.33. (P.No.51, I.No.
9.10 of PWD SR 2016-17)

9.11 KSRB 9.4-2 : Providing Honne wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves ( excluding cost of cement concrete and
side clamps ), but including cost of materials, labour, HOM of machineries cum 87604.00
complete as per specifications. Specification No. KBS 9.33

9.12 KSRB 9.4-3 : Providing Mathi / Nandi wood frames of doors, windows,
clerestory windows, ventilators and other frames, wrought, framed or
assembled including making plaster groves ( excluding cost of cement
concrete and side clamps ), but including cost of materials, labour, HOM of cum 73196.00
machineries complete as per specifications. Specification No. KBS 9.33

9.13 KSRB 9.4-4 : Providing WHITE Sal wood frames of doors, windows,
clerestory windows, ventilators and other frames, wrought, framed or
assembled including making plaster groves ( excluding cost of cement
concrete and side clamps ), but including cost of materials, labour, HOM of cum 60548.00
machineries complete as per specifications. Specification No. KBS 9.33. (P.
No. 51/ I. No. 9.13 of CSR 2016-17)

9.13.1 KSRB 9.4-4 : Providing RED Sal wood frames of doors, windows, clerestory
windows, ventilators and other frames, wrought, framed or assembled
including making plaster groves ( excluding cost of cement concrete and
side clamps ), but including cost of materials, labour, HOM of machineries cum 60614.00
complete as per specifications. Specification No. KBS 9.33

9.14 KSRB 9.5-1 : Providing and fixing in position fully panelled Teak wood
shutters for doors, styles and rails of 40mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 8108.00
machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34

9.15 KSRB 9.5-2 : Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 40mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 4722.00
machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34

9.16 KSRB 9.5-3 : Providing and fixing in position fully panelled Mathi/Nandi
wood shutters for doors, styles and rails of 40mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 4176.00
machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34

9.17 KSRB 9-6.1 : Providing and fixing in position fully panelled Teak wood
shutters for doors, styles and rails of 35mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 7638.00
machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34

9.18 KSRB 9-6.2 : Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 35mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 4504.00
machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34

Page 34 of 375
9.19 KSRB 9-6.3 : Providing and fixing in position fully panelled Mathi/ Nandi
wood shutters for doors, styles and rails of 35mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 3996.00
machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34
Page No. 53
9.20 KSRB 9-7.1 : Providing and fixing in position fully panelled Teak wood
shutters for doors, styles and rails of 30mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 7168.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

9.21 KSRB 9-7.2 : Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 30mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 4287.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

9.22 KSRB 9-7.3 :Providing and fixing in position fully panelled Mathi/ Nandi
wood shutters for doors, styles and rails of 30mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 3817.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

9.23 KSRB 9-8.1 : Providing and fixing in position fully panelled Teak wood
shutters for doors, styles and rails of 25mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 6733.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

9.24 KSRB 9-8.2 : Providing and fixing in position fully panelled Honne wood
shutters for doors, styles and rails of 25mm. thick with bottom and lock
rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 4069.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

9.25 KSRB 9-8.3 : Providing and fixing in position fully panelled Mathi/ Nandi
wood shutters for doors, styles and rails of 25mm. thick with bottom and
lock rails 180mm wide top rail and styles 100mm wide as per drawing and
panels of 25mm thick including cost of materials, labour, HOM of Sqm 2558.00
machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

9.26 KSRB 9-9.1: Providing and fixing in position Teak wood half panelled and
half glazed shutters for doors, styles and rails of 40mm. thick with bottom
and lock rails 180mm wide top rail and styles 100mm wide as per drawing
and panels of 25mm thick, 4mm thick plain glass, fixed with beading
15mm wide and thickness to finish with the shutters surface including cost Sqm 7096.00
of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.27 KSRB 9-9.2: Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 40mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 4288.00
including cost of materials, labour, HOM of machineries complete as per
specifications. ( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.28 KSRB 9-10.1 : Providing and fixing in position Teak wood half panelled and
half glazed shutters for doors, styles and rails of 35mm. thick with bottom
and lock rails 180mm wide top rail and styles 100mm wide as per drawing
and panels of 25mm thick, 4mm thick plain glass, fixed with beading
15mm wide and thickness to finish with the shutters surface including cost Sqm 6626.00
of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures )

Page 35 of 375
9.29 KSRB 9-10.2 :Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 35mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 4070.00
including cost of materials, labour, HOM of machineries complete as per
specifications. (excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

Page No. 54
9.30 KSRB 9-11.1 : Providing and fixing in position Teak wood half panelled and
half glazed shutters for doors, styles and rails of 30mm. thick with bottom
and lock rails 180mm wide top rail and styles 100mm wide as per drawing
and panels of 25mm thick, 4mm thick plain glass, fixed with beading
15mm wide and thickness to finish with the shutters surface including cost Sqm 6062.00
of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.31 KSRB 9-11.2 : Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 30mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 25mm thick, 4mm thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 3809.00
including cost of materials, labour, HOM of machineries complete as per
specifications. ( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.32 KSRB 9-12.1 : Providing and fixing in position Teak wood half panelled and
half glazed shutters for doors, styles and rails of 30mm. thick with bottom
and lock rails 180mm wide top rail and styles 100mm wide as per drawing
and panels of 20mm thick, 4mm. thick plain glass, fixed with beading
15mm wide and thickness to finish with the shutters surface including cost Sqm 5801.00
of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.33 KSRB 9-12.2 : Providing and fixing in position Honne wood half panelled
and half glazed shutters for doors, styles and rails of 30mm. thick with
bottom and lock rails 180mm wide top rail and styles 100mm wide as per
drawing and panels of 20mm thick, 4mm. thick plain glass, fixed with
beading 15mm wide and thickness to finish with the shutters surface Sqm 3678.00
including cost of materials, labour, HOM of machineries complete as per
specifications. ( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.34 KSRB 9-13-1: Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 3684.00
HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4

9.35 KSRB 9-13-2 : roviding and fixing in position shutters for doors made out of
Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 3665.00
HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4 on one side

9.36 KSRB 9-13-3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 40mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade plain particle board including cost of Sqm 3529.00
materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.26.3

9.37 KSRB 9-14-1: Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 3433.00
HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4

Page 36 of 375
9.38 KSRB 9-14-2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side including cost of materials, labour, Sqm 3447.00
HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4 one side

Page No. 55
9.39 KSRB 9-14-3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 35mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade plain particle board including cost of Sqm 3442.00
materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.26.3

9.40 KSRB 9-15-1: Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade Melamine impregnated prelamination particle
board of approved colour on both sides including cost of materials, labour, Sqm 3249.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.3

9.41 KSRB 9-15-2 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade Melamine impregnated prelamination particle
board of approved colour on one side including cost of materials, labour, Sqm 3229.00
HOM of machineries complete as per specifications. (excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.3 one side

9.42 KSRB 9-15-3 : Providing and fixing in position shutters for doors made out
of Honne wood styles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and styles 100mm wide as per drawing and panels of
18mm thick of exterior grade Plain particle board including cost of Sqm 3094.00
materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.26.3

9.43 KSRB 9-16.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and rails of 35mm. thick, 75mm wide in
two halves with panels of 25mm thick including cost of materials, labour Sqm 8221.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures ) Specification No. KBS 9.34
9.44 KSRB 9-16.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 35mm. thick, 75mm wide in
two halves with panels of 25mm thick including cost of materials, labour Sqm 4929.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures ) Specification No. KBS 9.34
9.45 KSRB 9-16.3 : Providing and fixing in position Mathi/ Nandi wood fully
panelled shutters for windows with styles and rails of 35mm. thick, 75mm
wide in two halves with panels of 25mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 4345.00
(excluding cost of fixtures ) Specification No. KBS 9.34

9.46 KSRB 9-16.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 35mm. thick, 75mm wide in
two halves with panels provided with NUWUD ( MDF ) of 25mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 3934.00
as per specifications. (excluding cost of fixtures ) Specification No. KBS
9.34, 9.26.3

9.47 KSRB 9-17.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and rails of 30mm. thick, 75mm wide in
two halves with panels of 20mm thick including cost of materials, labour Sqm 7122.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures ) Specification No. KBS 9.34
Page No. 56
9.48 KSRB 9-17.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 30mm. thick, 75mm wide in
two halves with panels of 20mm thick including cost of materials, labour Sqm 4379.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures ) Specification No. KBS 9.34

Page 37 of 375
9.49 KSRB 9-17.3 : Providing and fixing in positionMathi/ Nandi wood fully
panelled shutters for windows with styles and rails of 30mm. thick, 75mm
wide in two halves with panels of 20mm thick including cost of materials, Sqm 3892.00
labour charges, HOM of machineries complete as per specifications.
(excluding cost of fixtures ) Specification No. KBS 9.34
9.50 KSRB 9-17.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 30mm. thick, 75mm wide in
two halves with panels provided with NUWUD ( MDF ) of 18mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 3659.00
as per specifications. ( excluding cost of fixtures ) Specification No. KBS
9.34, 9.26.3

9.51 KSRB 9-18.1 : Providing and fixing in position Teak wood fully panelled
shutters for windows with styles and rails of 25mm. thick, 75mm wide in
two halves with panels of 20mm thick including cost of materials, labour Sqm 6572.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures ) Specification No. KBS 9.34
9.52 KSRB 9-18.2 : Providing and fixing in position Honne wood fully panelled
shutters for windows with styles and rails of 25mm. thick, 75mm wide in
two halves with panels of 20mm thick including cost of materials, labour Sqm 4103.00
charges, HOM of machineries complete as per specifications. (excluding
cost of fixtures ) Specification No. KBS 9.34
9.53 KSRB 9-18.3 : Providing and fixing in position Mathi/ Nandi wood fully
panelled shutters for windows with styles and rails of 25mm. thick, 75mm
wide in two halves with panels of 20mm thick including cost of materials,
labour charges, HOM of machineries complete as per specifications. Sqm 3666.00
(excluding cost of fixtures ) Specification No. KBS 9.34

9.54 KSRB 9-18.4 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 25mm. thick, 75mm wide in
two halves with panels provided with NUWUD ( MDF ) of 18mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 3145.00
as per specifications. ( excluding cost of fixtures ) Specification No. KBS
9.34, 9.26.3

9.55 KSRB 9-18.5 : Providing and fixing in position fully panelled shutters for
windows with Honne wood styles and rails of 25mm. thick, 75mm wide in
two halves with panels provided with NUWUD ( MDF ) of 12mm thick
including cost of materials, labour charges, HOM of machineries complete Sqm 3111.00
as per specifications. ( excluding cost of fixtures ) Specification No. KBS
9.34, 9.26.3

9.56 KSRB 9-19.1 : Providing and fixing in position Teak wood half panelled
shutters at bottom and half glazed at top for window shutters with styles
and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm
thick, 3mm thick reeded glass for top panels fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete
as per specifications. ( excluding cost of fixtures) Specification No. Providing
and fixing in position Teak wood half panelled shutters at bottom and half
glazed at top for window shutters with styles and rails of 35mm. thick, Sqm 7163.00
75mm wide in two halves with panels of 25mm thick, 3mm thick reeded
glass for top panels fixed with wooden beading including cost of materials,
labour charges, HOM of machineries complete as per specifications.
( excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.57 KSRB 9-19.2 :Providing and fixing in position Honne wood half panelled
shutters at bottom and half glazed at top for window shutters with styles
and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm
thick, 3mm thick reeded glass for top panels fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete
as per specifications. ( excluding cost of fixtures) Specification No. Providing
and fixing in position Teak wood half panelled shutters at bottom and half
glazed at top for window shutters with styles and rails of 35mm. thick, Sqm 4557.00
75mm wide in two halves with panels of 25mm thick, 3mm thick reeded
glass for top panels fixed with wooden beading including cost of materials,
labour charges, HOM of machineries complete as per specifications.
( excluding cost of fixtures) Specification No. KBS 9.34, 9.42

Page 38 of 375
9.58 KSRB 9-19.3 :Providing and fixing in position Mathi/ Nandi wood half
panelled shutters at bottom and half glazed at top for window shutters with
styles and rails of 35mm. thick, 75mm wide in two halves with panels of
25mm thick, 3mm thick reeded glass for top panels fixed with wooden
beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. ( excluding cost of fixtures) Specification No.
Providing and fixing in position Teak wood half panelled shutters at bottom
and half glazed at top for window shutters with styles and rails of 35mm. Sqm 4095.00
thick, 75mm wide in two halves with panels of 25mm thick, 3mm thick
reeded glass for top panels fixed with wooden beading including cost of
materials, labour charges, HOM of machineries complete as per
specifications. ( excluding cost of fixtures) Specification No. KBS 9.34, 9.42

Page No : 57
9.59 KSRB 9-19.4 :Providing and fixing in position windows half paneled
shutters at bottom and half glazed at top for window shutters with Honne
wood styles and rails of 35mm. thick, 75mm wide in two halves with panels
filled with NUWUD ( MDF ) of 18mm thick, 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour Sqm 3830.00
charges, HOM of machineries complete as per specifications. ( excluding
cost of fixtures ) Specification No. KBS 9.34, 9.42, 9.26.3

9.60 KSRB 9-20.1 : Providing and fixing in position Teak wood half panelled
shutters at bottom and half glazed at top for window shutters with styles
and rails of 30mm. thick, 75mm wide in two halves with panels of 20mm
thick, 3mm thick reeded glass for top panels fixed with wooden beading Sqm 6476.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42

9.61 KSRB 9-20.2 : Providing and fixing in position Honne wood half panelled
shutters at bottom and half glazed at top for window shutters with styles
and rails of 30mm. thick, 75mm wide in two halves with panels of 20mm
thick, 3mm thick reeded glass for top panels fixed with wooden beading Sqm 4213.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42

9.62 KSRB 9-20.3 : Providing and fixing in position Mathi/ Nandi wood half
panelled shutters at bottom and half glazed at top for window shutters with
styles and rails of 30mm. thick, 75mm wide in two halves with panels of
20mm thick, 3mm thick reeded glass for top panels fixed with wooden Sqm 3812.00
beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. (excluding cost of fixtures) Specification No.
KBS 9.34, 9.42

9.63 KSRB 9-20.4 : Providing and fixing in position windows half paneled
shutters at bottom and half glazed at top for window shutters with Honne
wood styles and rails of 30mm. thick, 75mm wide in two halves with panels
filled with NUWUD (MDF ) of 18mm thick, 3mm thick reeded glass for top
panels fixed with woodenbeading including cost of materials, labour Sqm 3393.00
charges, HOM of machineries completeas per specifications. ( excluding
cost of fixtures ) Specification No. KBS 9.34,9.42, 9.26.3

9.64 KSRB 9-21.1 : Providing and fixing in position half panelled shutters at
bottomand half glazed at top for window shutters with Teak wood styles
and rails of25mm. thick, 75mm wide in two halves with panels of 20mm
thick, 3mm thick reeded glass for top panels fixed with wooden beading Sqm 5936.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42

9.65 KSRB 9-21.2 : Providing and fixing in position half panelled shutters at
bottomand half glazed at top for window shutters with Honne wood styles
and rails of25mm. thick, 75mm wide in two halves with panels of 20mm
thick, 3mm thick reeded glass for top panels fixed with wooden beading Sqm 3947.00
including cost of materials, labour charges, HOM of machineries complete
as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34,
9.42

9.66 KSRB 9-21.3 : Providing and fixing in position half panelled shutters at
bottomand half glazed at top for window shutters with Mathi/ Nandi wood
styles and rails of25mm. thick, 75mm wide in two halves with panels of
20mm thick, 3mm thick reeded glass for top panels fixed with wooden Sqm 3588.00
beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. (excluding cost of fixtures) Specification No.
KBS 9.34, 9.42

Page 39 of 375
9.67 KSRB 9-21.4 : Providing and fixing in position windows half paneled
shutters at bottom and half glazed at top for window shutters with Honne
wood styles and rails of 25mm. thick, 75mm wide in two halves with panels
filled with NUWUD ( MDF ) of 18mm thick, 3mm thick reeded glass for top
panels fixed with wooden beading including cost of materials, labour Sqm 3119.00
charges, HOM of machineries complete as per specifications. ( excluding
cost of fixtures ) Specification No. KBS 9.34, 9.42, 9.26.3

Page No : 58
9.68 KSRB 9-22.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 35mm. thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 5277.00
as per specifications. (excluding cost of fixtures ) Specification No. KBS
9.34, 9.42

9.69 KSRB 9-22.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 35mm. thick 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 3557.00
as per specifications. (excluding cost of fixtures ) Specification No. KBS
9.34, 9.42

9.70 KSRB 9-23.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 30mm. thick, 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 4865.00
as per specifications. ( excluding cost of fixtures ) Specification No. KBS
9.34, 9.42

9.71 KSRB 9-23.2 :Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 30mm. thick, 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials, labour charges, HOM of machineries complete Sqm 3351.00
as per specifications. ( excluding cost of fixtures ) Specification No. KBS
9.34, 9.42

9.72 KSRB 9-24.1 : Providing and fixing in position fully glazed for windows
shutters with Teak wood styles and rails of 25mm. thick, 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials,labour charges, HOM of machineries complete Sqm 4452.00
as per specifications. ( excluding cost of fixtures ) Specification No. KBS
9.34, 9.42

9.73 KSRB 9-24.2 : Providing and fixing in position fully glazed for windows
shutters with Honne wood styles and rails of 25mm. thick, 75mm wide in
single shutters with 4mm thick plain glass fixed with wooden beading
including cost of materials,labour charges, HOM of machineries complete Sqm 3144.00
as per specifications. ( excluding cost of fixtures ) Specification No. KBS
9.34, 9.42

9.74 KSRB 9-25.1 :Providing and fixing in position fully glazed shutters for
ventilators side hung or central pivoted with Teak wood styles and rails of
30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the Sqm 6214.00
thickness of the frame including cost of materials, labour charges, HOM of
machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

9.75 KSRB 9-25.2 :Providing and fixing in position fully glazed shutters for
ventilators side hung or central pivoted with Honne wood styles and rails of
30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the Sqm 4088.00
thickness of the frame including cost of materials, labour charges, HOM of
machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

9.76 KSRB 9-25.3 : Providing and fixing in position fully glazed shutters for
ventilators side hung or central pivoted with Mathi/ Nandi wood styles and
rails of 30mm. thick, 50mm wide and central divider of 30mm. wide, 3mm
thick reeded glass fixed with wooden beading of size 10mm wide flushed to
the thickness of the frame including cost of materials, labour charges, HOM Sqm 3675.00
of machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

Page No. 59

Page 40 of 375
9.77 KSRB 9-26.1 : Providing and fixing in position fully glazed shutters for
ventilators side hung or central pivoted with Teak wood styles and rails of
25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the Sqm 3738.00
thickness of the frame including cost of materials, labour charges, HOM of
machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

9.78 KSRB 9-26.2 : Providing and fixing in position fully glazed shutters for
ventilators side hung or central pivoted with Honne wood styles and rails of
25mm. thick, 50mm wide and central divider of 25mm. wide, 3mm thick
reeded glass fixed with wooden beading of size 10mm wide flushed to the Sqm 2576.00
thickness of the frame including cost of materials, labour charges, HOM of
machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

9.79 KSRB 9-26.3 : Providing and fixing in position fully glazed shutters for
ventilators side hung or central pivoted with Mathi/ Nandi wood styles
and rails of 25mm. thick, 50mm wide and central divider of 25mm. wide,
3mm thick reeded glass fixed with wooden beading of size 10mm wide
flushed to the thickness of the frame including cost of materials, labour Sqm 2338.00
charges, HOM of machineries complete as per specifications. ( excluding
cost of fixtures ) Specification No. KBS 9.34, 9.42

9.80 KSRB 9-27.1 : Fixing of door frame in an existing opening including


embeeding frame in floor and walls after cutting masonry for holdfasts for
embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good
the damages to walls and floor as required and disposal of the debries with Nos 1366.00
lead upto 50 m. including cost of materials, labour charges, complete as per
specifications. (P.No. 57, I.No. 9.80 of PWD SR 2016-17)

9.81 KSRB 9-27.2 : Fixing of window frame in an existing opening including


embeeding frame in floor and walls after cutting masonry for holdfasts for
embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good Nos 928.00
the damages to walls and floor as required and disposal of the debries with
lead upto 50 m. including cost of materials, labour charges, complete as per
specifications.

9.82 KSRB 9-27.3 : Fixing of ventilator frame in an existing opening including


embeeding frame in floor and walls after cutting masonry for holdfasts for
embedding holdfast in cement concrete 1:3:6 of 20mm and down size
granite metal painting two coats of coal tar to sides of frame, making good Nos 791.00
the damages to walls and floor as required and disposal of the debries with
lead upto 50 m. including cost of materials, labour charges, complete as per
specifications.

9.83 SOLID PANEL PVC DOOR SHUTTER Providing & fixing 30mm thick factory
made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge
thickness, size 19x19mm fro styles and 15x15mm for top & bottom rails,
covered with heat moulded PVC channel of 5mm thick sheet & 30 x 50mm
wide to form styles & 5mm thick & 75mm wide PVC Sheets for top rail, lock
rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap
insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in Sqm 2777.00
the M.S. Frame, Sealed to the styles & rails with 5x30mm PVC sheet
beading on either side & joined together with solvent cement adhesive etc.,
Complete as per manufacturers specification & direction of Engineer-in-
charge fixed to frames with 3 nos of 75 m.m Aluminium hinges.

9.84 SOLID PVC DOOR FRAME Providing & fixing factory made PVC Door frame
of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm
rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm
long brackets of 15x15mm M.S Square tube, the entire door frame to be
reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to Sqm 468.00
be fixed to the wall using M.S. Screws of 65/80mm size complete as per
manufacturers specification & direction of Engineer-in-charge.

Page No. 60

Page 41 of 375
9.85.1 SOLID PANEL PRELAM PVC DOOR SHUTTER Providing & fixing 30mm
thick factory made rigid foam Prelam Panelled Door Shutters made from
M.S. tube of 19x19mm, 19 gauge for styles and 15x15mm for top & bottom
rails, covered with heat moulded Prelaminated PVC C Channel of 5mm
thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide
Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side
& 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail &
bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side Sqm 3746.00
fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer
beading on either side & joined together with solvent cement adhesive etc.,
Complete as per manufacturers specification & direction of Engineer-in-
charge fixed to frames with 3 nos of 75mm. Aluminium hinges.
with both side prelam

9.85.2 SOLID PANEL PRELAM PVC DOOR SHUTTER Providing & fixing 30mm
thick factory made rigid foam Prelam Panelled Door Shutters made from
M.S. tube of 19x19mm, 19 gauge for styles and 15x15mm for top & bottom
rails, covered with heat moulded Prelaminated PVC C Channel of 5mm
thick sheet & 30x50mm wide to form styles & 5mm thick & 75mm wide
Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side
& 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail &
bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side Sqm 2798.00
fitted in the M.S. frame, Sealed to the styles & rails with PVC Designer
beading on either side & joined together with solvent cement adhesive etc.,
Complete as per manufacturers specification & direction of Engineer-in-
charge fixed to frames with 3 nos of 75mm. Aluminium hinges.
with one side prelam

9.86 PVC DOOR SHUTTER (Nandi or Equivalent) Supply and fixing of door
shuttersmade of rigid PVC extruded hollow section (Nandi or equivalent) o f
20mm x 200mm with the wall thickness of 1.0mm + /0.1mm equally
divided into 4nos with tongue and groove locking arrangements. The
shutter frame is made of 58x24 mm with the wall thickness of 1.5mm+/ -
0.15mm section metricut and joined at 4 corners with 125mmx225mm
Sqm 1785.00
plastic brackets. The shutter shall be horizontally reinforced with 2nos of
8mm PVC rods. Teak wood battons shall be reinforced inside the door
shutter during the fabrication of the door shutter at those points wherever
the hardware is fixed on to the door shutter.

9.87 Supply and fixing of door shutters made of rigid PVC extruded hollow
section (Nandi or equivalent) of 20mmx200mm with the wall thickness of
1.0mm+/-0.1mm equally divided into 4nos with tongue an groove locking
arrangements. The shutter frame is made of 30mm x 79mm with the wall
thickness of 1.5mm+/-0.15mm section metric cut and joined at 4 corners
with 125mmx225mm plastic brackets. The shutter shall be horizontally Sqm 2000.00
reinforced with 2nos of 8mm PVC rods. Teak wood battons shall be
reinforced inside the door shutter during the fabrication of the door shutter
at those points wherever the hardware is fixed on to the door shutter.

9.88 Supply and fixing of door frame made of hollow extruded PVC Section
(Nandi or Equivalent) having dimension of 40x57mm with the wall
thickness of 2mm+/-0.2mm duly reinforced with seasoned wood plank at m 250.00
the hinges side. The door frame top 2corners shall be metric cut/ welded.

9.89 Supply and fixing of door frame made of hollow extruded PVC Section
(Nandi or Equivalent) having dimension of 40x46mm with the wall
thickness of 2mm+/-0.2mm duly reinforced with seasoned wood plank at m 250.00
the hinges side. The door frame top 2 corners shall be metric cut/ weilded .

Page No. 61

Page 42 of 375
9.90.1 Providing and fixing factory made splendoor of solid core single leaf rigid
composite polymer laminated sal wood, door shutter of required thickness,
manufactured out of solid core door conforming to IS 2202 (Part-1) 1991,
laminated with 0.8 mm thick polymer, termite, water resistant and fire
retardant with superior gluing based on vacuum lamination technology and
with various pre moulded design on both faces conforming to IS 6307-1985,
using adhesive conforming to IS 4835-1979 and door shuters tested in
conformation to IS 4020-1994. The finish of shutters will be Sqm 3250.00
TEADK/OAK/CEDAR/ROSE WOOD/ WALNUT, plain colurs
WHITE/IVORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot.
with door shutter 30mm thick

9.90.2 Providing and fixing factory made splendoor of solid core single leaf rigid
composite polymer laminated sal wood, door shutter of required thickness,
manufactured out of solid core door conforming to IS 2202 (Part-1) 1991,
laminated with 0.8 mm thick polymer, termite, water resistant and fire
retardant with superior gluing based on vacuum lamination technology and
with various pre moulded design on both faces conforming to IS 6307-1985,
using adhesive conforming to IS 4835-1979 and door shuters tested in
conformation to IS 4020-1994. The finish of shutters will be Sqm 3800.00
TEADK/OAK/CEDAR/ROSE WOOD/ WALNUT, plain colurs
WHITE/IVORY/BEIGE/LIGHT GREY. Excluding cost of fixtures and
inclusive of supply of shutters to respective work spot.
with door shutter 35mm thick

9.91 Providing and fixind of factory made 30mm P.V.C rigid foam (FOREX)
PANEL DOORS Rajashree made from MS tube of 19 guage, size of 19mm x
19mm and covered with heat moulded PVC C Channel of 5 mm thick and
width of 50mm to form styles and rails. The inner panel should be inserted
in between the frame with 5mm thick PVC rigid foam sheet, welded/sealed Sqm 2400.00
to the styles and rails along with 5mm PVC, beeding on all and either sides.
The vertical tubes may be filled with suitable wood material to further
enhance the screw holding capacity

9.92 Providing and fixing PVC Hollow Door Frame of the size 50x47mm with a
wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet,
mitre cut at two corners and joined with 2 Nos. of 150mm long brackets of
15x15mm M.S. Square tube. The two vertical door profiles are to be
reinforced with 19x19 mm M.S. Square tube of 19 gauge, EPDM rubber m 360.00
gasket weather seal to be provided through out the frame. The door screws
through the frame by using PVC fasteners. A minimum of 4 Nos of screws
to be provided for each vertical member & minimum 2 Nos. for horizontal
member.

9.93 Providing and fixing factory made single leaft rigid GRP Sandwich
composite door shutter of 32mm thick, laminated with two GRP skins with
wood grain finish, fabricated using U.V-stabilized Isopthalic Gelcoat and on
layer of 45 gsm E-Glass Chopped strand Mat (CSM), impregnated with
orthopthalic polyster resin. The thickness of the skins shall not be less than
1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm
thickness and a density of 20 Kg/m3 shall be used as core material.
Wooden reinforcements made of Seasoned Salwood block of cross section
not less than 28mmx32mm and also necessary salwood reinforcements for
fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be Sqm 3000.00
provided. A structural adhesive compatible with EPS foam shall be used for
bonding the core material, the Salwood reinforcement and the skins. The
material and process for manufacturing the door shutters shall confirm to
RV/TIFAC Composites Design centre Standards and specifications and the
door shutters tested in confiramation to IS 4020-1994. The finish of shutter
will be plain colour White/Ivory/Beige/Light Grey or any other colour using
high quality pigments. Exclusing cost of fixtures and inclusive of supply of
shutters to respective work spot.

Page 43 of 375
9.94 Providing and fixing factory made single leaf rigid GRP Sandwich composite
door shutter of 40 mm thick, laminated with two GRP skins with wood
grain finish, fabricated using U.V-stabilized Isopthalic Gelcoat and one
layer of 450 gns E-Glass Chopped Strand Mat (CSM), impregnated with
orthopthalic polyester resin. The thickness of the skins shall not be less
than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 37mm
thickness and a density of 20 Kg/m3 shall be used as core material.
Wooden reinforcements made of Seasoned Salwood block of cross section
not lessthan 36mmx32mmand also necessary salwood reinforcements for
fixing the metal fittings such as tower bolts, aldrops, handles, etc. shall be Sqm 3800.00
provided. A structural adhesive compatible with EPS foam shall be used for
bonding the core material, the salwood reinforement and the skins. The
material and process for manufacturing the door shutters shall confirm to
RV-TIFAC Composites Design Centre Standards and specifications and the
door shutters tested in confiramation to IS 4020-1994. The finish of shutter
will be plain coulur White/IVORY/Beige/Light Grey or any other colour
using high quality pigments. Excluding cost of fixtures and inclusive of
supply of shutters to respective work spot. (P.No.60, I.No.9.94 of PWD SR
2015-16)
Page No. 62
9.95 Providing and fixing 65mmx90mm GRP Doorframe fabricated using E-Glass
Chopped Strand Mat (CSM). U.V-stabilized Isopthalic Gelcoat and Isopthalic
resin. The thickness of the GRP skin shall not be less than 2.0 mm. The
doorframe consists of four segmens, which are provided with plug-in-socket
arrangement in-situ in the mould. The segments are plugged in and are
joined together by means of screws. The GRP frame shall be provided with
m 450.00
wooden reinforcement of 6 locations fro high screw holding capacity for
fixing metallic hold fast and shall be consolidated by filling with medium
density foam/Plaster with fibre reinforcement. Six Numbers of
260mmx25mmx5mm size S shaped M.S. flat hold fast shall be provided
with the frame.

9.96 Providing and fixing 65mmx125mm GRP Doorframe fabricated using E-


Glass Chopped Strand Mat (CSM) U.V- stabilized Isopthalic Gelcoat and
Isopthalic resin. The thickness of the GRP skin shall not be less than
2.0mm. The doorframe consists of four segments, which are provided with
plug-in-socket arrangement in-situ in the mould. The segments are plugged
in and are joined together by means of screws. The GRP frame shall be
provided with wooden reinforcement on 6 locations for high screw holding m 550.00
capacity for fixing metalling hold fast and shall be consolidated by filling
with medium density foam/Plaster of Paris with fibre reinforcement. Six
Numbers of 260mmx25mmx5mm size S shaped M.S. flat hold fast shall be
provided with the frame.

9.97 Providing G.R.P. unbreakable railings available in a wide range of attractive


colours made out of cross section >70mmx64mm of standard length 7 feet
(approximate 3.6Kg/m). The material and process for manufacturing Each 400.00
railings shall confirm to RV-TIFAC composites design centre standards and
specifications.
9.98 Providing and fixing RCC door frames factory manufactured, with C.C. 1:1
1/2 :3 reinforced with 3 Nos. of 6 mm dia. Main bars and 6 mm dia.
Stirrups welded at 30 cm C/C, vibrating, curing including cost of steel and
fabrication charges having 3 Nos. of hinges with 20mm x 3mm M.S. flat
welded with required iron rods and flats with drilling and fixing 4 No.of flat
screw nuts each in concrete for fixing hinges and making necessary m 872.00
provision in concrete for fixing aldrops, tower bolts etc., including cost of
one coat of oil based enamel primer, 4 No.of hold fasts, 3 Nos. ISS Iron
oxidised hinges necessary metal screws etc., complete. 60mm x 100 mm
size-Door frames.

Page No. 63
9.99 Providing and fixing masquito mesh to mesh to windows with 7.5 mm to
1.25 mm thick Honne wood petties including labour charges etc., complete. Sqm 715.00

9.100 Providing and fixing require line and slope roofing with semi-corrugated
PVC roofing sheets of industrial profile 250/40 in 2.00 mm thick white
colour, fire and heat resistant having width of 1.054 mtrs. fixed with self
tapping screws with washers, over the existing purlins, rafters and trusses Sqm 820.00
including cost of materials, labour, complete as per specification.

Page 44 of 375
9.101 Providng and fixng Teak Wood Hand railing to stair case using bulusters of
sections 40mm x 25mm as per design drawing No: 11863 / railings issued
by the Principal Chief Architect and fixing it to the steps using anchor bolts
and necessary adhesive materiasl and fixing T.W.handrail of section 75 x
75 mm to bulusters and finishing the same by using colourless polish etc.,
complete. The work includes cost of all materials, labour charges for all m 11219.00
items of work, hire charges for welding, cutting and grinding equipment,
and electricity charges, with lead and lift, loading and unloading charges,
etc., complete as per drawing and specification

9.102 Providing Maranthi wood frames of doors, windows, clear story windows,
ventilation and other frames, wrought, framed or assembled including
making plaster grooves (excluding cost of concrete cement and side clamps) cum 45613.00
but including cost of materials, labours, HOM of machineries complete as
per specifications.
9.103 Providing & Fixing Mosquito mesh shutters made out of Stainless Steel
mosquito proof mesh with 95% & above visibility which is fixed to the
powder coated aluminium frame 32mm thick of approved shade. The work
including fixing the shutters with necessary accessories, to complete as per Sqm 3200.00
specification including the labour charges for fixing the shutter to the
existing frames.

9.104 Providing & Fixing Mosquito mesh shutters made out of Stainless Steel
mosquito proof mesh with 95% & above visibility which is fixed to the
powder coated aluminium frame 20mm thick of approved shade. The work
including fixing the shutters with necessary accessories, to complete as per Sqm 2900.00
specification including the labour charges for fixing the shutter to the
existing frames.
Page No. 64
9.106.1 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 3702.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 30mm thick both side teak

9.106.2 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 3156.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 30mm thick one side teak and one side
commercial

9.106.3 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 2308.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 30mm thick both side commercial

9.106.4 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 3944.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 35mm thick both side teak

9.106.5 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 3350.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 35mm thick one side teak and one side
commercial

Page 45 of 375
9.106.6 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 2550.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 35mm thick both side commercial. (P.
No. 62/ I.No. 9.106.6 of CSR 2015-16)

9.106.7 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 4065.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 40mm thick both side teak

9.106.8 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 3580.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 40mm thick one side teak and one side
commercial

9.106.9 Providing and fixing flush door shutter made out of solid core black board
type, well seasoned chemically treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame all-round door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door using liquid phenol formaldehyde resin sqm 2793.00
as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory)
complete as per specification. - 40mm thick both side commercial

9.107 Providing and fixing to the existing door frames, factory made single
leaf HDF – Teak Veneer skin sandwich composite door shutter of 40mm
thickness made out of honeycomb of 34 mm thick and surrounded by good
quality properly seasoned wooden reinforcements of size 33 mm X 65 mm
for fixing fixtures such as tower bolts, aldrops, handles etc., and laminated
on either sides with 3 mm thick wood grain finish good quality HDF-Teak
Veneer skins, using structural bonding material compatible with
honeycomb core, wood and HDF- Teak Veneer skin and the whole assembly
is bonded together at high temperature and pressure using 650 tonnage Sqm 2350.00
heated compression moulding press.All the four sides of the door shutter
are applied with two coats of UV stabilized polyester resin putty to
completely cover and seal the wood from water ingression.The material and
process for manufacturing the door shall confirm to RV-TIFAC composites
design centre standards and specification and the door shutters tested in
confirmation to IS4020-1994, including cost of all materials, labour
charges, HOM and machineries etc. complete but excluding the cost of
fixtures.

Page 46 of 375
9.108 Providing and fixing to the existing door frames, factory made
single leaf HDF skin sandwich composite door shutter of 40 mm
thickness made out of honeycomb of 34 mm thick and surrounded
by good quality properly seasoned wooden reinforcements of size
33 mm X 65 mm for fixing fixtures such as tower bolts, aldrops, handles
etc., and laminated on either sides with 3 mm thick wood grain finish good
quality HDF skins, using structural bonding material compatible with
honeycomb core, wood and HDF skin and the whole assembly is bonded
together at high temperature and pressure using 650 tonnage heated
compression moulding press. The HDF Composite door surface is coated
with 2 coats of high quality primer.The front and back surfaces of the door
shutter and all the four sides are painted with two coats of high quality
paint of any desired colour. The material and process for manufacturing the Sqm 1532.00
door shall confirm to RV-TIFAC composites design centre standards and
specification and the door shutters tested in confirmation to IS4020-1994,
including cost of all materials, labour
charges, HOM and machineries etc. complete but excluding the cost of
fixtures.

9.109 Providing and fixing to the existing door frames, factory made single leaf
HDF – Teak Veneer skin sandwich composite door shutter of 32 mm
thickness made out of honeycomb of 29 mm thick and surrounded by good
quality properly seasoned wooden reinforcements of size 28 mm X 40 mm
for fixing fixtures such as tower bolts, aldrops, handles etc., and laminated
on either sides with 3 mm thick wood grain finish good quality HDF- Teak
Veneer skins, using structural bonding material compatible with
honeycomb core, wood and HDF- Teak Veneer skin and
the whole assembly is bonded together at high temperature and pressure
using 650 tonnage heated compression moulding press. All the four sides of
the door shutter are applied with two coats of UV stabilized polyester resin Sqm 2128.00
putty to completely cover and seal the wood from water ingression.The
material and process for manufacturing the door shall confirm to RV-TIFAC
composites design centre standards and specification and the door shutters
tested in confirmation to IS4020-1994, including cost of all materials,
labour charges, HOM and machineries etc. complete
but excluding the cost of fixtures.

Page No. 65
9.110 Providing and fixing to the existing door frames, factory made single leaf
HDF skin sandwich composite door shutter of 32 mm thickness made out
of honeycomb of 26 mm thick and surrounded by good quality properly
seasoned wooden reinforcements of size 25 mm X 65 mm for fixing fixtures
such as tower bolts, aldrops, handles etc., and laminated on either sides
with 3 mm thick wood grain finish good quality HDF skins, using structural
bonding material compatible with honeycomb core, wood and HDF skin and
the whole assembly is bonded together at high temperature and pressure
using 650 tonnage heated compression moulding press. The HDF
Composite door surface is coated with 2 coats of high quality primer.The
front and back surfaces of the door shutter and all the four sides are
painted with two coats of high quality paint of any desired colour. The
Sqm 1437.00
material and process for manufacturing the door shall confirm to RV-TIFAC
composites design centre standards and specification and the door shutters
tested in confirmation to IS4020-1994, including cost of all materials,
labour charges, HOM and machineries etc. complete but excluding the cost
of fixtures.

Page 47 of 375
9.111 Providing and fixing to the existing door frames, factory made single leaf
HDF skin sandwich composite door shutter of 32 mm thickness made out
of honeycomb of 26 mm thick and surrounded by good quality properly
seasoned wooden reinforcements of size 25 mm x 65 mm for fixing fixtures
such as tower bolts, aldrops, handles etc., and laminated on either sides
with 3 mm thick wood grain finish good quality HDF skins, using structural
bonding material compatible with honeycomb core, wood and HDF skin and
the whole assembly is bonded together at high temperature and pressure
using 650 tonnage heated compression moulding press. The HDF
Composite door surface is coated with 2 coats of high quality primer.The
front and back surfaces of the door shutter and all the four sides are
painted with two coats of high quality paint of any desired colour. The
material and process for manufacturing the door shall confirm to RV-TIFAC Sqm 1655.00
composites design centre standards and specification and the door shutters
tested in confirmation to IS4020-1994, including cost of all materials,
labour charges, HOM and machineries etc. complete but excluding the cost
of fixtures.

Note :
1 Lift charges : The Above rates are applicable for ground floor only. An
additional rates of Rs. 4.00/sqm per floor may be added for every additional
floor above or below for items vide Sl.No.9.14 to 9.99, 9.101. 9,102 an
9.111
Page No. 66

10.0 10.WATER PROOFING


10.1 KSRB 10-2 : Providing and laying in position yelahanka tiles of size 250 x
250mm of approved quality and make, over a bed of cement mortar 1:3 an
average thickness 25mm over weather proof course and pointed with
cement mortar 1:3 mix with red oxide including curing cost of materials, Sqm 978.00
labour complete as per specifications. Specification No. KBS

10.2 KSRB 10-3 : Providing and laying integral cement based waterproofing
treatment including preparation of surface as required for treatment of
roofs, balconies, terraces etc., consisting of following application. (a)
Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of
cement admixed with proprietary water proofing compound conforming to
IS:2645 over the RCC slab after cleaning the surface before treatment. (b)
Laying cement concrete using broken brick bats 25mm to 100mm size with
50% of cement mortar 1:5 admixed with proprietary water proofing
compound conforming IS:2645 over 20mm thick layer of cement mortar 1:5
admixed with proprietary water proofing compound to required slope and
treating similarly the adjoining walls upto 300mm height including
rounding off junctions of walls and slabs. (c) After two days of proper
curing, applying a second coat of cement lurry admixed with proprietary
water proofing compound (d) Finishing the surface with 20mm thick
jointless cement mortar of mix 1:4 admixed with proprietary water proofing Sqm 1006.00
compound and finally finishing the surface with trowel and neat cement
slurry and making of 300x300mm square. (e) The whole terrace so finished
shall be flooded with water for a minimum period of two weeks for curing
and for final test including cost of materials, labour complete as per
specifications. (P.No. 66, I.No. 10.2 of PWD SR 2015-16)

Page 48 of 375
10.3 KSRB 10-4 : Providing and laying four courses water proofing treatment
with bitumen felt over roof consisting of first and third courses of blown
and / or residual bitumen applied hot at 1.45 kg / sqm of area for each
course second course of roofing felt Type - 3 grade-I ( hessian based self
finish bitumen felt ) and forth and final course of stone grit 6mm and down
size or pea sized gravel spread at 0.06 cum. / sqm including preparation of
surface but excluding grading complete with bitumen felt ( hessian based )
Sqm 240.00
Type - 3 grade-I blown or / and residual bitumen applied hot 1.4 kg / sqm
including cost of materials, labour complete as per specifications. KBS
10.4.3

10.4 KSRB 10-5 : Providing and laying six courses water proofing treatment with
bitumen felt over roof consisting of first, third and fifth courses of blown
and / or residual bitumen applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of
area respectively, second and fourth courses of roofing felt Type -2 grade-I
( fibre based self finish bitumen felt ) and sixth and final course of stone grit
6mm and down size or pea sized gravel spread at 0.06 cum. / sqm
including preparation of surface, excluding grading but including cost of Sqm 411.00
materials, labour complete as per specifications. KBS 10.4.3

Page No. 68
10.5.1 Waterproofing of RCC Terrace / podium slab / toilet / utilities / water
retaining structure by preparing the surface by chipping and cleaning and
Grouting of Honey comb, voids,cracks / construction joints with cement
slurry (1kg cement added in 10 ltr of water) added with 100gm of inorganic
accelerator, followed by spraying of liquid biological modified alkaline earth
silicates @ 0.40 ltr per sqm on whole surface to reduce the micro porosity
and allowing it to dry, curing the surface for the silicates to penetrate
deeper into the concrete and spraying waterproofing impregnate liquid sqm 526.00
containing silane and silanol linear copolymer @ 0.50 ltr per sqm and
finally applying polymer slurry made out of cross linked acrylic / styrene /
butadiene & cement in the ratio of 1:0.1, @0.50kg/sqm on the whole
surface, including all labour charges tools and equipments, all complete as
per the specification

10.5.2 Bore Packing : filling the bore wherever necessary with polymer modified
concrete and brushing one coat of acrylic copolymer cross linked
formulation on the bore. including all labour charges tools and equipments, sqm 216.00
all complete as per the manufacturer
10.5.3 Extra for water proofing the inside surface of tanks (OHT & UGT) - applying
of modified polymers soft acrylic esters coat @0.40 kg/sqm in 2 coats
including all labour charges tools and equipments, all complete as per the sqm 254.00
specification.

10.6 Providing and fixing food grade epoxy painting to over head tank and sump
tank after cleaning and drying including pumping and bailing out of water,
including cost of all materials labour lead and lifts etc., complete Sqm 88.00

10.7 Cleaning RCCsump tanks and RCC overhead tanks with mechanical
dewatering including removal of sludge, mud, dirt, algea etc and cleanuing
the wall surface of tanks using high pressure jet, vacuum cleaning and
spraying anti bacterial treatment to the wall and ceiling surfaces and UV
treatment, including removing of sludge etc., using suitable coconut
broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic
buckets, mugs, dewatering using motor with portal arrangement, hose pipe L 0.35
etc., complete including all safety measures.

Page 49 of 375
10.8 Providing and applying composite water proofing compound as impregnate
only on wet surfaces to arrest leaks in surfaces such as roof cealing,
internal and external walls, flooring and other surfaces apart from water
tanks, sumps, reservoirs, by mixing the composite waterproofing
compound with water in ratio of 1:10 to make a workable slurry and
pouring it on all cleaned and prepared corners and disturbed area and
further mixing in the ratio 1:20 AND pouring it on the prepared surface by sqm 577.00
cleaning the surface with etchant chemical from dirt foreign materials etc.,
and allowing it to be there upto 3 hours and then cleaning the same using
water complete as per specification so that the surface is got back and
ready to use after 4 hours.

Page No. 69
10.9 Providing and applying Polymer based water proofing slurry having
chemical resistance properties, capable of withstanding a Temperature of
200 DegC for Protective Negative coating for Water Dampness & seepages,
comprising of Portland cement, Lime stone, Silica sand, Alumina cement,
sodium aluminate in the form of powder composition at 3.30 kgs mixed
with 1.0 liter of Acrylic emulsion, applied on 0.64 Sqm area/liter of slurry
on a cleaned surface free of loose materials etc, complete on all masonry Sqm 2767.00
structures, overhead tank, sump tank, water closet areas, sunken slab and
other such areas, filling tile joints, capable of Self curing within 3 to 4
hours of its application in normal atmospheric condition, including cost of
all materials, labour charges, HOM and machineries etc., complete.

10.10 Providing and applying Polymer based instant running water leak arrester
in civil works using mixture capable of withstanding a temperature of 200
Deg C comprising of Portland cement, Lime stone, Silica sand, Alumina
cement, Sodium aluminate, Calcium oxide in the form of powder
composition of 1.00kg mixed with 250ml water, applied on a cleaned
surface free of loose materials, dust etc., for cavities and also for damaged
areas in all masonry and concrete structures, for rapid hardening and leak kg 1875.00
arresting including cost of all materials, labour charges, HOM and
machineries etc., complete.

10.11 Providing and applying water proofing in two coats of 300 microns
thickness on all surfaces like concrete, Metal, Plastic , Asbestos, Wood,
Cloth canopy using Heat refractive compound made out of Vinyl Acetate
copolymer latex, Water, Titanium Dioxide, Barium metaborate, Ceramic
Microsphere powder, Mica, Propylene Glycol in suitable proportions and the
surface to be treated should be cleared of loose particles/dust/fungus etc
and kept dry before the application of heat refractive compound, including Sqm 803.00
cost of all materials, labour charges, HOM and machineries etc., complete.

Note :
1 If can be fallowed by other operations like screeding, tiling etc., after 1 hout.
Do Not Farcibly remove composite waterproofing compound on tiles if any

Page No. 70

11.0 11.DRAINAGE WORK


11.1 KSRB 12-1.1 : Providing and laying in position to required level or slope
100mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 245.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.2 KSRB 12-1.2 : Providing and laying in position to required level or slope
150mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 368.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.3 KSRB 12-1.3 : Providing and laying in position to required level or slope
200mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and
joints,including cost of materials, labour charges complete as per m 487.00
specifications. Specification No. KBS 12.2.5 / 12.7 200mm

Page 50 of 375
11.4 KSRB 12-1.4 : Providing and laying in position to required level or slope
230mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 536.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.5 KSRB 12-1.5 : Providing and laying in position to required level or slope
250mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 579.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.6 KSRB 12-1.6 : Providing and laying in position to required level or slope
300mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 631.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.7 KSRB 12-1.7 : Providing and laying in position to required level or slope
350mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 682.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.8 KSRB 12-1.8 : Providing and laying in position to required level or slope
400mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 744.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.9 KSRB 12-1.9 : Providing and laying in position to required level or slope
450mm internal diameter salt glazed stoneware pipes grade A and jointing
with stiff mixture of cement mortar in proportion of 1:1, testing of pipes and m 874.00
joints,including cost of materials, labour charges complete as per
specifications. Specification No. KBS 12.2.5 / 12.7
11.10 KSRB12-2.1 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 100mm internal
diameter stoneware pipes including cost of materials, labour charges, HOM m 242.00
of machinery, curing complete as per specifications Specification No. KBS
4.1 / 4.2

11.11 KSRB 12-2.2 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 150mm internal
diameter stoneware pipes including cost of materials, labour charges, HOM m 408.00
of machinery, curing complete as per specifications Specification No. KBS
4.1 / 4.2

11.12 KSRB 12-2.3 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 200mm internal m 454.00
diameter stoneware pipes including cost of materials, labour charges, HOM
of machinery, curing
11.13 KSRB 12-2.4 :Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 230mm internal m 489.00
diameter stoneware pipes including cost of materials, labour charges, HOM
of machinery, curing
11.14 KSRB 12-2.5 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 250mm internal
diameter stoneware pipes including cost of materials, labour charges, HOM m 510.00
of machinery, curing complete as per specifications Specification No. KBS
4.1 / 4.2

11.15 KSRB 12-2.6 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 300mm internal
diameter stoneware pipes including cost of materials, labour charges, HOM m 581.00
of machinery, curing complete as per specifications Specification No. KBS
4.1 / 4.2 300mm

11.16 KSRB 12-2.7 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 350mm internal
diameter stoneware pipes including cost of materials, labour charges, HOM m 653.00
of machinery, curing complete as per specifications Specification No. KBS
4.1 / 4.2

Page 51 of 375
11.17 KSRB 12-2.8 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 400mm internal
diameter stoneware pipes including cost of materials, labour charges, HOM m 724.00
of machinery, curing complete as per specifications Specification No. KBS
4.1 / 4.2

11.18 KSRB 12-2.9 : Providing and laying in position plain cement concrete M7.5
40mm and down size graded granite metal, machine mixed concrete laid in
layers not exceeding 15 cms thick, well compacted, for 450mm internal
diameter stoneware pipes including cost of materials, labour charges, HOM m 790.00
of machinery, curing complete as per specifications Specification No. KBS
4.1 / 4.2

11.19 KSRB 12-3.1 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 100mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 372.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

Page No. 72
11.20 KSRB 12-3.2 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 150mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 579.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

11.21 KSRB 12-3.3 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 200mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 682.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

11.22 KSRB 12-3.4 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 230mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 784.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

11.23 KSRB 12-3.5 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 250mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 795.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

11.24 KSRB 12-3.6 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 300mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 918.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

11.25 KSRB 12-3.7 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 350mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 1050.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

11.26 KSRB 12-3.8 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 400mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 1181.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

Page 52 of 375
11.27 KSRB 12-3.9 : Providing and laying in position plain cement concrete of mix
M 7.5 using 40mm and down size graded granite / trap metal for
haunching of 450mm internal diameter stoneware pipes, concrete machine
mixed laid in layers not exceeding 15 cms thick, well compacted, including m 1311.00
cost of materials, labour charges, form work, HOM of machinery, curing
complete as per specifications. Specification No. KBS 4.1 / 4.2

11.28 KSRB 12-4.1 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 100mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 761.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.29 KSRB 12-4.2 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 150mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 924.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.30 KSRB 12-4.3 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 200mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 1079.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.31 KSRB 12-4.4 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 230mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 1178.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.32 KSRB 12-4.5 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 250mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 1249.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.33 KSRB 12-4.6 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 300mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 1423.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.34 KSRB 12-4.7 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 350mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 1622.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.35 KSRB 12-4.8 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 400mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 1815.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

11.36 KSRB 12-4.9 : Providing and laying in position plain cement concrete of M
7.5 using 40mm and down size graded granite / trap metal for surrounded
encasing 450mm internal diameter stoneware pipes, concrete machine
mixed well compacted including cost of materials, labour charges, form m 2000.00
work, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1 / 4.2

Page 53 of 375
11.37 KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m
internal dia at bottom,0.91m deep and 0.56m dia at top with table
moulded non-modular bricks of 50 class designation 50 in cement mortar
1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished
with a floating coat of neat cement, foundation concrete M 10 using 40mm
and downsize granite metal and making necessary channel in cement
concrete M 50 with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS :12592, Nos 14705.00
total weight cover and frame to be not less than 182 kg, fixed in cement
concrete 1:2:4, 20mm and downsize broken granite metal, providing and
removing centering, shuttering including cost of materials, labour charges,
HOM of mechineries complete as per specifications. (Excavation, footrests
and 12mm thick cement plaster on the external surface shall be paid
seperately ) Specification No. KBS 12.4

Page No. 73
11.38 KSRB 12-5.2 : Constructing brick masonry circular type manhole 1.67 m
internal dia at bottom, 0.91m deep and 0.56m dia at top with table
moulded non-modular bricks of 50 class designation 50 in cement mortar
1:4, inside cement plastered 12mm thick with cement mortar 1:3, finished
with a floating coat of neat cement, foundation concrete M 10 using 40mm
and downsize granite metal and making necessary channel in cement
concrete M 50 with 20mm and downsize granite metal finished with a
floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty,
HD-20 grade designation) 560mm internal diametre confirming IS :12592, Nos 24284.00
total weight cover and frame to be not less than 182 kg, fixed in cement
concrete 1:2:4, 20mm and downsize broken granite metal, providing and
removing centering, shuttering including cost of materials, labour charges,
HOM of mechineries complete as per specifications. (Excavation, footrests
and 12mm thick cement plaster on the external surface shall be paid
seperately ) Specification No. KBS 12.4

11.39 KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22 m
internal dia at bottom, 1.68 m deep and 0.56m dia at top, with table
moulded and non modular bricks of class designation 50 in cement mortar
1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished
with a floating coat of neat cement, foundation concrete M 10 using 40mm
and down size granite metal and making necessary channel in cement
concrete M 15 with 20mm and down size granite metal, finished with a
floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty,
HD-20 grade designation) 560mm internal diameter confirming to Nos 29318.00
IS :12592, total weight length of cover and frame to be not less than 182 kg,
fixed in cement concrete M 15 20mm and down size broken granite metal,
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of mechineries complete as per specifications.
( Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately ) Specification No. KBS 12.4

11.40 KSRB 12-5.4 : – Constructing brick masonry circular type manhole 1.22 m
internal dia at bottom, 2.29m deep and 0.56m dia at top, with table
moulded and non modular bricks of class designation 50 in cement mortar
1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished
with a floating coat of neat cement, foundation concrete M 10 using 40mm
and down size granite metal and making necessary channel in cement
concrete M 15 with 20mm and down size granite metal, finished with a
floating coat of neat cement, with S.F.R.C. cover and frame ( heavy duty,
HD-20 grade designation) 560mm internal diameter confirming to Nos 34853.00
IS :12592, total weight length of cover and frame to be not less than 182 kg,
fixed in cement concrete M 15 20mm and down size broken granite metal,
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of mechineries complete as per specifications.
( Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately ) Specification No. KBS 12.4

Page 54 of 375
11.41 KSRB 12-5.5 : Constructing brick masonry circular type manhole 1.52 m
internal dia at bottom, 2.30m deep and 0.56m dia at top, with table
moulded and non-modular bricks of class designation 50 in cement mortar
1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished
with a floating coat of neat cement, foundation concrete M 10 mixed using
40mm and down size granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm anddown size granite metal, finished
with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy
duty, HD-20 grade designation) 560mm internal diameter confirming to
IS :12592, total weight length of cover and frame to be not less than 182 kg, Nos 45878.00
fixed in cement concrete M 15 20mm and down size broken granite metal,
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of mechineries complete as per specifications.
( Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately ) Specification No. KBS 12.4

11.42 KSRB 12-5.6 :Constructing brick masonry circular type manhole 1.52 m
internal dia at bottom, 4.18m deep and 0.56m dia at top, with table
moulded and non-modular bricks of class designation 50 in cement mortar
1:4, inside cement plaster 12mm thick with cement mortar 1:3, finished
with a floating coat of neat cement, foundation concrete M 10 mixed using
40mm and down size granite metal and making necessary channel in
cement concrete 1:2:4 mix with 20mm anddown size granite metal, finished
with a floating coat of neat cement, with S.F.R.C. cover and frame ( heavy
duty, HD-20 grade designation) 560mm internal diameter confirming to
IS :12592, total weight length of cover and frame to be not less than 182 kg, Nos 85449.00
fixed in cement concrete M 15 20mm and down size broken granite metal,
providing and removing centering, shuttering including cost of materials,
labour charges, HOM of mechineries complete as per specifications.
( Excavation, footrests and 12mm thick cement plaster on the external
surface shall be paid seperately ) Specification No. KBS 12.4

11.43 KSRB 12-5.7 : Constructing circular type manhole 1500mm internal dia
at bottom 2.50m deep 525mm dia at top, in brick masonry with 1:5
cement mortar, cement plaster 1:3, finish with a floating coat of neat
cement, RCC 1:2:4 top slab using 20mm and down size granite metal,
foundation concrete M 7.5 using 40mm and down size granite metal and
making channels in cement concrete M 15 using 20mm and down size
Nos 47043.00
granite metal, neatly finished curing, fixing CI cover complete including cost
of materials, labour charges, HOM of mechineries complete as per
specifications. (Excavation, footrests and 12mm thick cement plaster on
the external surface shall be paid seperately ) Specification No. KBS 12.4

Page No. 74
11.44 KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole
with M 10 cement concrete block of 20x20x10cms, using 20mm and down
size metal of size including cost of materials, labour charges, curing Nos 276.00
complete as per specifications. Specification No. KBS 12.4.6

11.45 KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole
with M 10 cement concrete block of 20x20x10cms, using 20mm and down
size metal of size including cost of materials, labour charges, curing Nos 254.00
complete as per specifications. Specification No. KBS 12.4.6

11.46 KSRB 12-6.3 : Providing cast iron footrest and fixing in manhole with M 10
cement concrete block of 20x20x10cms, using 20mm and down size metal
of size including cost of materials, labour charges, curing complete as per Nos 236.00
specifications. Specification No. KBS 12.4.6
11.47 KSRB 12-7.1 : Making connection of drain or sewer line of size 100 to
230mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete M 15 with 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3, finished Nos 2691.00
with a floating coat of neat cement, and making necessary channels for the
drain, including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

Page 55 of 375
11.48 KSRB 12-7.2 : Making connection of drain or sewer line of size 250 to
300mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete M 15 with 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3, finished Nos 3488.00
with a floating coat of neat cement, and making necessary channels for the
drain, including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

11.49 KSRB 12-7.3 : Making connection of drain or sewer line of size 350 to
450mm external dia with existing manhole including breaking into and
making good the walls, floors with cement concrete M 15 with 20mm and
downsize granite metal, cement plastered on both sides of mix 1:3, finished Nos 4451.00
with a floating coat of neat cement, and making necessary channels for the
drain, including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

11.50.1 Constructing brick masonry inspection chamber 455x610mm, and


450mm depth, ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5,
C.I cover withframe (light duty) 455x610mm internal dimensions, total
weight of cover with frame to be not less than 38 kg ( weight of cover 23kg
and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with
20mm and downsize granite metal, foundation concrete M 5 with 40mm
and downsize granite metal inside plastering 12mm thick with cement
mortar 1:3, finish smooth with a floating coat of cement on walls and bed
concrete complete as per standard design including cost of materials,
labour charges, curing complete as per specifications. Specification No. KBS
Nos. 7064.00
600x600mm and 450mm depth ( clear inside dimension ) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm. (P.No.
73/ I.No.11.50.1 of PWD SR 2015-16)

11.50.2 Constructing brick masonry inspection chamber 600x600mm, and


450mm depth, ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5,
C.I cover withframe (light duty) 455x610mm internal dimensions, total
weight of cover with frame to be not less than 38 kg ( weight of cover 23kg
and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with
20mm and downsize granite metal, foundation concrete M 5 with 40mm
and downsize granite metal inside plastering 12mm thick with cement
mortar 1:3, finish smooth with a floating coat of cement on walls and bed Nos. 8490.00
concrete complete as per standard design including cost of materials,
labour charges, curing complete as per specifications. Specification No. KBS
450x450mm and 450mm depth ( clear inside dimension ) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I cover withframe (light duty) 450x450mm (P.No.
73/ I.No.11.50.2 of PWD SR 2015-16)

Page No 75
11.50.3 Constructing brick masonry inspection chamber 450x450mm, and
450mm depth, ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5,
C.I cover withframe (light duty) 455x610mm internal dimensions, total
weight of cover with frame to be not less than 38 kg ( weight of cover 23kg
and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with
20mm and downsize granite metal, foundation concrete M 5 with 40mm
and downsize granite metal inside plastering 12mm thick with cement
mortar 1:3, finish smooth with a floating coat of cement on walls and bed Nos. 530.00
concrete complete as per standard design including cost of materials,
labour charges, curing complete as per specifications. Specification No. KBS
450x450mm and 450mm depth ( clear inside dimension ) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I cover withframe (light duty) 450x450mm (P.No.
73/ I.No.11.50.2 of PWD SR 2015-16)

Page 56 of 375
11.50.4 Constructing brick masonry inspection chamber 450x300mm, and
450mm depth, ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5,
C.I cover withframe (light duty) 455x610mm internal dimensions, total
weight of cover with frame to be not less than 38 kg ( weight of cover 23kg
and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with
20mm and downsize granite metal, foundation concrete M 5 with 40mm
and downsize granite metal inside plastering 12mm thick with cement
mortar 1:3, finish smooth with a floating coat of cement on walls and bed Nos. 3800.00
concrete complete as per standard design including cost of materials,
labour charges, curing complete as per specifications. Specification No. KBS
450x300mm and 450mm depth ( clear inside dimension ) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I cover withframe (light duty) 450x300mm

11.50.5 Constructing brick masonry inspection chamber 230x150mm, and


450mm depth, ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5,
C.I cover withframe (light duty) 455x610mm internal dimensions, total
weight of cover with frame to be not less than 38 kg ( weight of cover 23kg
and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with
20mm and downsize granite metal, foundation concrete M 5 with 40mm
and downsize granite metal inside plastering 12mm thick with cement
mortar 1:3, finish smooth with a floating coat of cement on walls and bed Nos. 1600.00
concrete complete as per standard design including cost of materials,
labour charges, curing complete as per specifications. Specification No. KBS
230x150mm and 450mm depth ( clear inside dimension ) for single
pipeline, using table moulded non-modular bricks of class designation 50
in cement mortar 1:5, C.I cover withframe (light duty) 230x150mm

11.51 KSRB 12-8.1.1 : Extra for item no. KSRB 12-8.1 depth beyond 450mm and
brick masonry chamber with table moulded non modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof Each 729.00
including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS
11.52 KSRB 12-8.2 : Constructing brick masonry inspection chamber
500x700mm, and 450mm depth, ( clear inside dimension ) for pipeline
with one or two inlets, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I cover with frame (light duty)
455x610mm internal dimensions, total weight of cover with frame to be not
less than 38 kg ( weight of cover 23kg and weight of frame 15 kg ) R.C.C.
top slab with cement concrete M 15 with 20mm and downsize granite metal
, foundation concrete M 5 with 40mm and downsize granite metal inside Each 7877.00
plastering 12mm thick with cement mortar 1:3, finished smooth with a
floating coat of cement on walls and bed concrete complete as per standard
design including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

11.53 KSRB 12-8.2.1 : Extra for item no. KSRB 12-8.2 depth beyond 450mm and
brick masonry chamber with table moulded non-modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof Each 811.00
including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS
11.54 KSRB 12-8.3 : Constructing brick masonry inspection chamber
600x850mm, and 450mm depth, ( clear inside dimension ) for pipeline
with three or more inlets, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I cover with frame (light duty)
455x610mm internal dimensions, total weight of cover with frame to be not
less than 38 kg ( weight of cover 23kg and weight of frame 15 kg ) R.C.C.
top slab with cement concrete M 15 with 20mm and downsize granite metal
, foundation concrete M 5 with 40mm and downsize granite metal inside Each 9030.00
plastering 12mm thick with cement mortar 1:3, finished smooth with a
floating coat of cement on walls and bed concrete complete as per standard
design including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

Page No. 76

Page 57 of 375
11.55 KSRB 12-8.3.1 : Extra for item no. KSRB12-8.3 depth beyond 450mm and
brick masonry chamber with table moulded non-modular bricks of class
designation 50 in cement mortar 1:5 for every 150mm depth or part thereof Each 942.00
including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS
11.56.1 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 431.00
including cost of all materials, with 90mm outer dia
11.56.2 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 606.00
including cost of all materials,with 110mm outer dia

11.56.3 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 989.00
including cost of all materials,with 140mm outer dia

11.56.4 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 1252.00
including cost of all materials,with 160mm outer dia

11.56.5 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 1580.00
including cost of all materials,with 200mm outer dia

11.56.6 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 1909.00
including cost of all materials,with 225mm outer dia

11.56.7 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 2894.00
including cost of all materials,with 250mm outer dia

11.56.8 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 3661.00
including cost of all materials,with 280mm outer dia

11.56.9 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00
kgf/sq.cm working pressure chemp plast / Wavin or equivalent make
with pipe fittings, wall clips, making good the wall, ceiling and floor, m 4646.00
including cost of all materials,with 315mm outer dia

Note :
1 The Items vide Sl.No. 11.10, to 11.18 are for cement concrete bedding for
stoneware pipes.
2 The Items vide Sl.No. 11.19 to 11.27 are for for hanuching of stoneware
pipes with cement concrete
3 The items vide Sl.No. 11.28 to 11.36 are for Haunching of stoneware
pipes with cement concrete surrounded encasing
4 The walls of manholes and inspection chambers shall be built of one brick
thickness i.e. 112.5mm for dephts upto 4.25m, Below a depth depth of 4.25
m in ordinary subsoil the wall thickness shall be increased to one and half
brick i.e. 168 75 mm and at 9.75m below ground two brick thick i.e. 225
mm walls shall be built
Page No. 77

12.0 SANITARY WORK

Page 58 of 375
12.1 KSRB 11-1 : Providing and fixing white vitreous china clay, water closet
Indian type ( Squatting pan ) of size 580mm with footrests, 100mm S or P
trap, 10 litre low level, P.V.C flushing cistern ( all are approved make ) with
fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and clamps,
overflow arrangements with specials and 25mm mosquito proof coupling of
approved design, painting of fittings and brackets, cutting and making good pan 3506.00
the wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11

12.2 KSRB 11-2 : Providing and fixing white vitreous china clay, water closet
Orissa pattern of size 580 x 440mm with integral type footrests, 100mm S
or P trap, 10 litre low level, P.V.C flushing cistern ( all are approved make )
with fittings, C.I / M.S brackets, 32mm diameter flush pipe fittings and
clamps, overflow arrangements with special and 25mm mosquito proof
coupling of approved design, painting of fittings and brackets, cutting and pan 4224.00
making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications. Specification No. KBS 11.
(P.No. 77, I.No.12.2 of PWD SR 2015-16)

12.3 KSRB 11-3 : Providing and fixing white vitreous china clay, water closet
Indian type ( Squatting pan ) of size 580mm with footrests, 100mm S or P
trap, (approved make) cutting and making good the wall and floor wherever pan 1331.00
required, including cost of materials, labour complete as per specifications.

12.4 KSRB 11-4 : Providing and fixing white vitreous china clay, water closet
Orissa pattern of size 580 x 440mm with integral type footrests, 100mm S
or P trap, (approved make ) cutting and making good the wall and floor pan 2067.00
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11
12.5 KSRB 11-5 : Providing and fixing white vitreous china clay, water closet
European type ( Pedestal type, P-trap ) with black solid plastic seat and lid,
C.P brass hinges, rubber buffers. 10 litre low level, P.V.C flushing cistern
( all are approved make ) with fittings, C.I / M.S brackets, 40mm diameter
flush bend with fittings and clamps, overflow arrangements with special
and 25mm mosquito proof coupling of approved design, painting of fittings Each 4956.00
and brackets, cutting and making good the wall and floor wherever
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.6 KSRB 11-6 : Providing and fixing white vitreous china clay, water closet
European type ( Pedestal type, S-trap ) with black solid plastic seat and lid,
C.P brass hinges, rubber buffers. 10 litre white glazed / vitreous china clay
low level, flushing cistern ( all are approved make ) with fittings, C.I / M.S
brackets, 40mm diameter flush bend with fittings and clamps, overflow
arrangements with specials and 25mm mosquito proof coupling of approved Each 4807.00
design, painting of fittings and brackets, cutting and making good the wall
and floor wherever required, including cost of materials, labour complete as
per specifications. Specification No. KBS 11

Page No. 79
12.7 KSRB 11-7.1 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430x260x350mm with 5 litres PVC automatic
flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass
spreaders with brass unions and G.I. clamps complete painting of fittings Unit 3072.00
and brackets, cutting and making good the wall and floor wherever
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.8 KSRB 11-7.2 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430x260x350mm in the range of two 7.5 litre
P.V.C with automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps painting Unit 4165.00
of fittings and brackets, cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.9 KSRB 11-7.3 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430x260x350mm in the range of three with 7.5
litres PVC automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps painting Unit 5814.00
of fittings and brackets, cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

Page 59 of 375
12.10 KSRB 11-7.4 : Providing and fixing white vitreous china clay, flat back,
lipped front urinal basin of 430x260x350mm in the range of four with 10
litres PVC automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps complete Unit 7091.00
painting of fittings and brackets, cutting and making good the wall and
floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.11 KSRB 11-8.1 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340x410x265mm with 5 litres P.V.C
automatic flushing cistern, C.I / M.S brackets, standard flush pipe and
C.P. brass spreaders with brass unions and G.I. clamps complete painting Unit 2984.00
of fittings and brackets, cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

Page No. 80
12.12 KSRB 11-8.2 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340x410x265mm in the range of two
with 7.5 litre P.V.C automatic flushing cistern, C.I / M.S brackets, standard
flush pipe and C.P. brass spreaders with brass unions and G.I. clamps
painting of fittings and brackets, cutting and making good the wall and Unit 3832.00
floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.13 KSRB 11-8.3 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340x410x265mm in the range of three
with 7.5 litre P.V.C automatic flushing cistern, C.I / M.S brackets, standard
flush pipe and C.P. brass spreaders with brass unions and G.I. clamps
painting of fittings and brackets, cutting and making good the wall and Unit 4495.00
floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.14 KSRB 11-8.4 : Providing and fixing white vitreous china clay, wall corner
type, lipped front urinal basin of size 340x410x265mm in the range of four
with 10 litre P.V.C automatic flushing cistern, C.I / M.S brackets, standard
flush pipe and C.P. brass spreaders with brass unions and G.I. clamps
painting of fittings and brackets, cutting and making good the wall and Unit 5157.00
floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.15 KSRB 11-9.1 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580x380x350mm with 5 litres P.V.C automatic
flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass
spreaders with brass unions and G.I. clamps C.I dtrap with outlet grating
and other couplings in C.P brass, painting of fittings and brackets, cutting Unit 4975.00
and making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications.

12.16 KSRB 11-9.2 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580x380x350mm in the range of two with 7.5
litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps, C.I. trap
with outlet grating and other couplings in C.P brass painting of fittings and Unit 8073.00
brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.17 KSRB 11-9.3 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580x380x350mm in the range of three with 10
litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps, C.I. trap
with outlet grating and other couplings in C.P brass painting of fittings and Unit 10985.00
brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications.
Specification No. KBS 11

Page No. 81
12.18 KSRB 11-9.4 : Providing and fixing white vitreous china clay, flat back or
half stall urinal basin of size 580x380x350mm in the range of four with 10
litres P.V.C automatic flushing cistern, C.I / M.S brackets, standard flush
pipe and C.P. brass spreaders with brass unions and G.I. clamps, C.I. trap
with outlet grating and other couplings in C.P brass painting of fittings and Unit 13897.00
brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications.
Specification No. KBS 11

Page 60 of 375
12.19 KSRB 11-10.1 : Providing and fixing white vitreous china clay, squatting
plate with 5 litre P.V.C automatic flushing cistern including brass coupling
C.I / M.S brackets, G.I flush pipe of standard size and C.P. brass spreaders
painting of fittings and brackets, cutting and making good the wall and Unit 3389.00
floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.20 KSRB 11-10.2 : Providing and fixing white vitreous china clay, squatting
plate in the range of two single squatting plate with 7.5 litre P.V.C
automatic flushing cistern including brass coupling C.I / M.S brackets, G.I
flush pipe of standard size and C.P. brass spreaders painting of fittings and Unit 5161.00
brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.21 KSRB 11-10.3 : Providing and fixing white vitreous china clay, squatting
plate in the range of three single squatting plates with 10 litre P.V.C
automatic flushing cistern including brass coupling C.I / M.S brackets, G.I
flush pipe of standard size and C.P. brass spreaders painting of fittings and Unit 6747.00
brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.22 KSRB 11-10.4 : Providing and fixing white vitreous china clay, squatting
plate in the range of four single squatting plates with one number 15 litre
P.V.C automatic flushing cistern including brass coupling C.I / M.S
brackets, G.I flush pipe of standard size and C.P. brass spreaders painting Unit 8439.00
of fittings and brackets, cutting and making good the wall and floor
wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.23 KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back
wash basin size 630x450mm with a pair of 15mm C.P brass pillar taps with
C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 4007.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11
Page No. 82
12.24 KSRB 11-11.2 : Providing and fixing white vitreous china clay, flat back
wash basin size 630x450mm with a single 15mm C.P brass pillar tap with
C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 3149.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11. (P.No. 81, I.No. 12.24 of PWD SR 2015-16)

12.25 KSRB 11-11.3 : Providing and fixing white vitreous china clay, flat back
wash basin size 550x400mm with a pair of 15mm C.P brass pillar taps with
C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 3879.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.26 KSRB 11-11.4 : Providing and fixing white vitreous china clay, flat back
wash basin size 550x400mm with a single 15mm C.P brass pillar tap with
C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 3021.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.27 KSRB 11-11.5 : Providing and fixing white vitreous china clay, flat back
wash basin size 450x300mm with a single 15mm C.P brass pillar tap with
C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 2807.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.28 KSRB 11-11.6 : Providing and fixing white vitreous china clay, angle back
wash basin size 600x480mm with a single 15mm C.P brass pillar tap with
C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 3288.00
required, including cost of materials, labour complete as per specifications.

12.29 KSRB 11-11.7 : Providing and fixing white vitreous china clay, angle back
wash basin size 400x400mm with a single 15mm C.P brass pillar tap with
C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of
fittings and brackets, cutting and making good the wall and floor wherever Unit 3026.00
required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

Page 61 of 375
12.30 KSRB 11-11.8 : Providing and fixing white vitreous china clay, surgeon type
wash basin size 660x460mm with a pair of 15mm C.P brass pillar taps with
pair of elbow operated levers, C.I / M.S brackets, 32 mm C.P. brass waste
of standard pattern, painting of fittings and brackets, cutting and making Unit 4605.00
good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. KBS 11

12.31 KSRB 11-11.9 : Providing and fixing white vitreous china clay, surgeon type
wash basin size 660x460mm with single 15mm C.P brass pillar tap with
single elbow operated lever, C.I / M.S brackets, 32 mm C.P. brass waste of
standard pattern, painting of fittings and brackets, cutting and making Unit 4082.00
good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. KBS 11

Page No. 83
12.32 KSRB 11-12.1 : Providing and fixing kitchen sink of white glazed fire clay of
size 600x450x250mm with M.S / C.I brackets, C.P brass chain with rubber
plug, 32 mm C.P. brass waste, tap with union, brass stop cock complete,
painting of fittings and brackets, cutting and making good the wall and Unit 3493.00
floor wherever required, including cost of materials, labour complete as per
specifications. KBS 11

12.33 KSRB 11-12.2 : Providing and fixing kitchen sink of white glazed fire clay of
size 750x450x250mm with M.S / C.I brackets, C.P brass chain with rubber
plug, 32 mm C.P. brass waste, tap with union, brass stop cock complete,
painting of fittings and brackets, cutting and making good the wall and Unit 4114.00
floor wherever required, including cost of materials, labour complete as per
specifications. KBS 11

12.34 KSRB 11-13.1 : Providing and fixing laboratory sink of white glazed fire clay
of size 600x450x200mm with M.S / C.I brackets, C.P brass chain with
rubber plug, 32 mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the Unit 3559.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications. KBS 11

12.35 KSRB 11-13.2 : Providing and fixing laboratory sink of white glazed fire clay
of size 450x300x150mm with M.S / C.I brackets, C.P brass chain with
rubber plug, 32 mm C.P. brass waste, tap with union, brass stop cock
complete, painting of fittings and brackets, cutting and making good the Unit 3260.00
wall and floor wherever required, including cost of materials, labour
complete as per specifications KBS 11

12.36 KSRB 11-14.1 : Providing and fixing stainless steel kitchen sink of size
510x1040mm bowl depth 178mm, with drain board, M.S / C.I brackets,
stainless steel plug 40 mm, painting of fittings and brackets, cutting and Unit 14254.00
making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications.
12.37 KSRB 11-14.2 : Providing and fixing stainless steel kitchen sink of size
500x1000mm bowl depth 178mm, with drain board, M.S / C.I brackets,
stainless steel plug 40 mm, painting of fittings and brackets, cutting and Unit 8860.00
making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications.
12.38 KSRB 11-14.3 : Providing and fixing stainless steel kitchen sink of size
400x915mm bowl depth 160mm, with drain board, M.S / C.I brackets,
stainless steel plug 40 mm, painting of fittings and brackets, cutting and Unit 6454.00
making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications.
12.39 KSRB 11-15.1 : Providing and fixing 600x450mm bevelLead edge mirror of
superior glass with 6mm hard board backing and fixed to wooden cleats
with C.P screws, washers, including cost of materials, labour complete as Unit 1157.00
per specifications.
12.40 KSRB 11-15.2 : Providing and fixing 450mm dia circular shape mirror with
plastic moulded frame of approved make and shade with 6mm thick hard
board backing including cost of materials, labour complete as per Unit 828.00
specifications.
12.41 KSRB 11-15.3 : Providing and fixing 453x357mm dia rectangular shape
mirror with plastic moulded frame of approved make and shade with 6mm
thick hard board backing including cost of materials, labour complete as Unit 1136.00
per specifications. (P.No.82, I.No. 12.41 of PWD SR 2015-16)

Page No. 84
12.42 KSRB 11-15.4 : Providing and fixing 450x350mm dia oval shape mirror
with plastic moulded frame of approved make and shade with 6mm thick
hard board backing including cost of materials, labour complete as per Unit 874.00
specifications.

Page 62 of 375
12.43 KSRB 11-15.5 : Providing and fixing 1500x450mm dia rectangular shape
mirror with plastic moulded frame of approved make and shade with 6mm
thick hard board backing including cost of materials, labour complete as Unit 1481.00
per specifications. (P.No.83. I.No. 12.43 of PWD SR 2015-16)

12.44 KSRB 11-16 : Providing and fixing 600x120mm glass shelf supported on
alluminium angle frame with C.P brass brackets, guard rail fixed to wooden
cleats with C.P. brass screws and washers including cost of materials, Unit 1082.00
labour complete as per specifications.
12.45 KSRB 11-17-1 : Providing and fixing C.P. brass towel rail 740mm length,
20mm dia with C.P brackets, fixed to wooden cleats with C.P. brass screws
including cost of materials, labour complete as per specifications. Unit 739.00

12.46 KSRB 11-17.2 : Providing and fixing C.P. brass towel rail 600 mm length,
20mm dia with C.P brackets, fixed to wooden cleats with C.P. brass screws
including cost of materials, labour complete as per specifications. Unit 674.00

12.47 KSRB 11-18-1.1 : Providing and fixing sand cast iron soil waste and vent
pipes 100mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per m 666.00
specifications. KBS 11-1.10
12.48 KSRB 11-18-1.2 : Providing and fixing sand cast iron soil waste and vent
pipes 75mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per m 634.00
specifications.KBS 11-1.10
12.49 KSRB 11-18-1.3 : Providing and fixing sand cast iron soil waste and vent
pipes 50mm dia with spun yarn soaked in cement slurry and cement
mortar 1:2 including cost of materials, labour, testing complete as per m 324.00
specifications. KBS 11-1.10
12.50 KSRB 11-18-2.1 : Providing and fixing sand cast iron soil waste bends 100
mm dia with access door, insertion of rubber washers 3mm thick bolts and
nut, with spun yarn soaked in cement slurry and cement mortar 1:2 Each 507.00
including cost of materials, labour, testing complete as per specifications.

12.51 KSRB 11-18-2.2 : Providing and fixing sand cast iron soil waste bends
75mm dia with access door, insertion of rubber washers 3mm thick bolts
and nut, with spun yarn soaked in cement slurry and cement mortar 1:2 Each 435.00
including cost of materials, labour, testing complete as per specifications.

12.52 KSRB 11-18-2.3 : Providing and fixing sand cast iron soil waste bends
50mm dia with access door, insertion of rubber washers 3mm thick bolts
and nut with spun yarn soaked in cement slurry and cement mortar 1:2 Each 414.00
including cost of materials, labour, testing complete as per specifications

12.53 KSRB 11-18-3.1 : Providing and fixing sand cast iron soil waste plain bend,
100mm dia with spun yarn soaked in cement slurry and cement mortar 1:2
including cost of materials, labour, testing complete as per specifications. Each 974.00
KBS 11-1.10
12.54 KSRB 11-18-3.2 : Providing and fixing sand cast iron soil waste plain bend,
75mm dia with spun yarn soaked in cement slurry and cement mortar 1:2
including cost of materials, labour, testing complete as per specifications Each 315.00
KBS 11-1.10
12.55 KSRB 11-18-3.3 : Providing and fixing sand cast iron soil waste plain bend,
50mm dia with spun yarn soaked in cement slurry and cement mortar 1:2
including cost of materials, labour, testing complete as per specifications. Each 352.00
KBS 11-1.10
Page No. 85
12.56 KSRB 11-18-4.1 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 100x100x100x100mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 1078.00
materials, labour, testing complete as per specifications. KBS 11-1.10

12.57 KSRB 11-18-4.2 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 75x75x75x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 798.00
materials, labour, testing complete as per specifications. KBS 11-1.10

12.58 KSRB 11-18-4.3 : Providing and fixing sand cast iron soil waste double
equal junction of required degree with access door 50x50x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 705.00
materials, labour, testing complete as per specifications. KBS 11-1.10

Page 63 of 375
12.59 KSRB 11-18-5.1 : Providing and fixing sand cast iron soil waste single equal
junction of required degree with access door 100x100x100mm, insertion of
rubber washers 3mm thick bolts and nuts, including cost of materials, Each 933.00
labour, testing complete as per specifications. KBS 11-1.10

12.60 KSRB 11-18-5.2 : Providing and fixing sand cast iron soil waste single equal
junction of required degree with access door 75x75x75mm, insertion of
rubber washers 3mm thick bolts and nuts, including cost of materials, Each 705.00
labour, testing complete as per specifications. KBS 11-1.10

12.61 KSRB 11-18-5.3 : Providing and fixing sand cast iron soil waste single equal
junction of required degree with access door 50x50x50mm, insertion of
rubber washers 3mm thick bolts and nuts, including cost of materials, Each 560.00
labour, testing complete as per specifications. KBS 11-1.10

12.62 KSRB 11-18-6.1 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 100x100x75x75mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 1078.00
materials, labour, testing complete as per specifications. KBS 11-1.10

12.63 KSRB 11-18-6.2 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 100x100x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 1078.00
materials, labour, testing complete as per specifications. KBS 11-1.10

12.64 KSRB 11-18-6.3 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree with access door 75x75x50x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 456.00
materials, labour, testing complete as per specifications. KBS 11-1.10

12.65 KSRB 11-18-7.1 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door
100x100x75mm,insertion of rubber washers 3mm thick bolts and nuts, Each 829.00
including cost of materials, labour, testing complete as per specifications.
KBS 11-1.10
12.66 KSRB 11-18-7.2 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 100x100x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 788.00
materials, labour, testing complete as per specifications. Specification No.
KBS 11.1.10
12.67 KSRB 11-18-7.3 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree with access door 75x75x50mm,
insertion of rubber washers 3mm thick bolts and nuts, including cost of Each 570.00
materials, labour, testing complete as per specifications Specification No.
KBS 11.1.10
12.68 KSRB 11-18-8.1 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 100x100x100x100mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 860.00
KBS 11.1.10
Page No. 86
12.69 KSRB 11-18-8.2 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 75x75x75x75mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 653.00
KBS 11.1.10
12.70 KSRB 11-18-8.3 : Providing and fixing sand cast iron soil waste double
equal junction of required degree 50x50x50x50mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 445.00
KBS 11.1.10
12.71 KSRB 11-18-9.1 : Providing and fixing sand cast iron soil waste single equal
junction of required degree with access door 100x100x100mm, including
cost of materials, labour, testing complete as per specifications. Each 933.00
Specification No. KBS 11.1.10
12.72 KSRB 11-18-10.1 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree100x100x75x75mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 1078.00

12.73 KSRB 11-18-11.1 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 100x100x75mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 507.00

Page 64 of 375
12.74 KSRB 11-18-11.2 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 100x100x50mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 523.00

12.75 KSRB 11-18-11.3 : Providing and fixing sand cast iron soil waste single
unequal junction of required degree 75x75x50mm, including cost of
materials, labour, testing complete as per specifications. KBS 11-1.10 Each 435.00

12.76 KSRB 11-18-12.1 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 100x100x100x100mm,
including cost of materials, labour, testing complete as per specifications. Each 990.00
Specification No. KBS 11.1.10
12.77 KSRB 11-18-12.2 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 75x75x75x75mm, including
cost of materials, labour, testing complete as per specifications. Each 653.00
Specification No. KBS 11.1.10
12.78 KSRB 11-18-12.3 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 50x50x50x50mm, including
cost of materials, labour, testing complete as per specifications Each 451.00
Specification No. KBS 11.1.10
12.79 KSRB 11-18-13.1 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 100x100x100x100mm,
including cost of materials, labour, testing complete as per specifications. Each 912.00
Specification No. KBS 11.1.10
12.80 KSRB 11-18-13.2 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 75x75x75x75mm, including
cost of materials, labour, testing complete as per specifications. Each 705.00
Specification No. KBS 11.1.10
12.81 KSRB 11-18-13.3 : Providing and fixing sand cast iron soil waste single
equal invert plain branches of required degree 50x50x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 622.00
Specification No. KBS 11.1.10
12.82 KSRB 11-18-14.1 : Providing and fixing sand cast iron soil waste double
unequal invert plain branches of required degree 100x100x75x75mm,
including cost of materials, labour, testing complete as per specifications. Each 1047.00
Specification No. KBS 11.1.10
12.83 KSRB 11-18-14.3 : Providing and fixing sand cast iron soil waste double
equal invert plain branches of required degree 75x75x50x50mm, including
cost of materials, labour, testing complete as per specifications. Each 580.00
Specification No. KBS 11.1.10
Page No. 87
12.84 KSRB 11-18-15.1 : Providing and fixing sand cast iron soil waste single
unequal invert plain branches of required degree 100x100x75mm,
including cost of materials, labour, testing complete as per specifications. Each 508.00
Specification No. KBS 11.1.10
12.85 KSRB 11-18-15.2 : Providing and fixing sand cast iron soil waste single
unequal invert plain branches of required degree 75x75x50mm including
cost of materials, labour, testing complete as per specifications. Each 435.00
Specification No. KBS 11.1.10
12.86 KSRB 11-18-16.1 : Providing and fixing sand cast iron soil waste 152mm
offsets for 100mm pipes, including cost of materials, labour, testing Each 674.00
complete as per specifications. Specification No. KBS 11.1.10
12.87 KSRB 11-18-16.2 : Providing and fixing sand cast iron soil waste 114mm
offsets for 75mm pipes, including cost of materials, labour, testing complete Each 425.00
as per specifications. Specification No. KBS 11.1.10
12.88 KSRB 11-18-16.3 : Providing and fixing sand cast iron soil waste 230 mm
offsets for 75mm pipes, including cost of materials, labour, testing complete Each 726.00
as per specifications. Specification No. KBS 11.1.10
12.89 KSRB 11-18-17.1 : Providing and fixing sand cast iron trap of 100mm dia,
of self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of
materials, labour, testing, complete as per specifications Specification No. Each 830.00
KBS 11.1.10. (P.No.86, I.No.12.89 of PWD SR 2015-16)

12.90 KSRB 11-18-17.2 : Providing and fixing sand cast iron trap of 75mm dia, of
self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of Each 756.00
materials, labour, testing, complete as per specifications. Specification No.
KBS 11.1.10

Page 65 of 375
12.91 KSRB 11-18-17.3 : Providing and fixing sand cast iron trap of 50mm dia, of
self cleaning design with screwed down or hinged grating with or without
vent arm including cutting and making good the walls and floors, cost of Each 698.00
materials, labour, testing, complete as per specifications. Specification No.
KBS 11.1.10
12.92 KSRB 11-18-18.1 : Providing lead caulked joints to sand cast iron / cast
iron ( spun ) pipes and fittings of 100mm dia, including cost of materials,
labour, testing, complete as per specifications. Specification No. KBS 13.2.7 Joint 129.00

12.93 KSRB 11-18-18.2 : Providing lead caulked joints to sand cast iron / cast
iron ( spun) pipes and fittings of 75mm dia, including cost of materials,
labour, testing, complete as per specifications specification No. KBS 13.2.7 Joint 111.00

12.94 KSRB 11-18-18.3 : Providing lead caulked joints to sand cast iron / cast
iron ( spun) pipes and fittings of 50mm dia, including cost of materials,
labour, testing, complete as per specifications Specification No. KBS 13.2.7 Joint 93.00

12.95 KSRB 11-18-9.2 : Providing and fixing sand cast iron soil waste single equal
junction of required degree with access door 75x75x75mm, including cost
of materials, labour, testing complete as per specifications Specification No. Each 705.00
KBS 11.1.10
Page No. 88
12.96 KSRB 11-18-9.3 : Providing and fixing sand cast iron soil waste single equal
junction of required degree with access door 50x50x50mm, including cost
of materials, labour, testing complete as per specifications. Specification Each 560.00
No. KBS 11.1.10
12.97 KSRB 11-18-10.2 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree100x100x50x50mm, including cost of
materials, labour, testing complete as per specifications. Specification No. Each 1078.00
KBS 11.1.10
12.98 KSRB 11-18-10.3 : Providing and fixing sand cast iron soil waste double
unequal junction of required degree 75x75x50x50mm, including cost of
materials, labour, testing complete as per specifications. Each 580.00

12.99 KSRB 11-18-19.1 : Providing and fixing M.S stays and clamps for sand cast
iron pipes of 100mm dia including cost of materials, labour, complete as No 328.00
per specifications.
12.100. KSRB 11-18-19.2 : Providing and fixing M.S stays and clamps for sand cast
iron pipes of 75mm dia including cost of materials, labour, complete as per No 308.00
specifications.
12.101 KSRB 11-18-19.3 : Providing and fixing M.S stays and clamps for sand cast
iron pipes of 50mm dia including cost of materials, labour, complete as per No 58.00
specifications.
12.102 KSRB 11-18-14.2 : Providing and fixing sand cast iron soil waste double
unequal invert plain branches of required degree 100x100x75x75mm
including cost of materials, labour, testing complete as per specifications. Each 1029.00
Specification No. KBS 11.1.10
12.103 Providing (China Clay) glazed foot rests of approved 1st quality and make
conforming to ISI specifications and fixing in CM (1:3) as directed (Rate
includes cost of materials and conveyance to work spot). Pair 175.00

12.104.1 Providing plastic seat with approved 1st quality and make conforming to ISI
specifications double flapped and fixing to English water closet with all
fittings (Rate includes cost of materials, fixtures and conveyance to work Pair 265.00
spot). - WHITE
12.104.2 Providing plastic seat with approved 1st quality and make conforming to ISI
specifications double flapped and fixing to English water closet with all
fittings (Rate includes cost of materials, fixtures and conveyance to work Pair 225.00
spot). - BLACK
12.105. Providing 3 cms dia GI telescopic flush tank lever of approved 1st quality
and make conforming to ISI specifications and fixing in position as directed
by the Engineer. Rate includes cost of materials and conveyance to work Each 210.00
spot.
12.106. Providing vulcanizing or rubber float of approved 1st quality and make
conforming to ISI Specifications and fixing for low down cistern as
directed .Rate includes cost of materials and conveyance to work spot. Each 165.00

12.107. Providing wash basin brackets of approved 1st quality and make
conforming to ISI Specifications and fixing for low down cistern as
directed .Rate includes cost of materials and conveyance to work spot. Pair 240.00

Page 66 of 375
12.108. Providing pedestal for wash basin of approved 1st quality and make
conforming to ISI Specifications and fixing for low down cistern as
directed .Rate includes cost of materials and conveyance to work spot. Each 900.00

Page No. 89
12.109. Providing and fixing white vitreous china clay urinals with flat back of
approved make fixed to wooden plugs including bends, painting white to
exposed pipes etc., complete as per directions.(rate includes cost of all Each 850.00
materials and lead).A grade.
12.110. Providing white vitreous china clay Indian pattern squatting urinals with
white glazed foot rests of approved quality and make conforming to ISI
specifications and fixing in Position with M-15 as directed of size 50.8 cms
X 38 cms X 10.16 cms - A Grade (Rate includes cost of all materials and Each 950.00
conveyance to work spot). (P.No. 88, I.No. 12.110 of PWD SR 2015-16)

12.111 Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia.
Each 150.00
(P.No. 88, I.No. 12.111 of PWD SR 2015-16)
12.112.1 Providing stoneware gully trap of approved quality and make fixing in M-15
and plastering with CM 1:3 wherever necessary.( Rate includes cost of all Each 190.00
materials, fixtures and lead).- 10cms x 10cms
12.112.2 Providing stoneware gully trap of approved quality and make fixing in M-15
and plastering with CM 1:3 wherever necessary.( Rate includes cost of all Each 280.00
materials, fixtures and lead). - 15cms x 10cms
12.113.1 Providing and fixing CI Nahani trap of approved make conforming to ISI
specifications and construction of Cistern in M-15 as per directions (Rate is
inclusive of cost of materials and fixtures and conveyance of materials to Each 250.00
work spot). - 10cms x 7.5cms
12.113.2 Providing and fixing CI Nahani trap of approved make conforming to ISI
specifications and construction of Cistern in M-15 as per directions (Rate is
inclusive of cost of materials and fixtures and conveyance of materials to Each 285.00
work spot). - 12.5cms x 7.5cms
12.114.1 Cleaning the blockages of closets and soil pipes into working order with
m 60.00
scaffolding
12.114.2 Cleaning the blockages of closets and soil pipes into working order without
m 50.00
scaffolding
12.114.3 Cleaning the blockages of closets and soil pipes into working order
m 20.00
underground stone ware pipes
12.115. Providing and fixing white vitreous china clay, wall corner type, lipped
front watrless urinal basin of size 328x319x598mm C.I / M.S brackets,
standard flush pipe complete painting of fittings and brackets, cutting and unit 23862.00
making good the wall and floo
12.116.1 Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00
kgs/sqcm working pressure with pipe fittings, wall clips etc., and making
good the wall, ceiling and floor for sanitary pipelines including cost of all m 434.00
materials, labour charges, HOM of acquirements and testing complete as
per specifications. - 110mm dia
12.116.2 Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00
kgs/sqcm working pressure with pipe fittings, wall clips etc., and making
good the wall, ceiling and floor for sanitary pipelines including cost of all m 688.00
materials, labour charges, HOM of acquirements and testing complete as
per specifications. - 140mm dia
12.116.3 Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00
kgs/sqcm working pressure with pipe fittings, wall clips etc., and making
good the wall, ceiling and floor for sanitary pipelines including cost of all m 853.00
materials, labour charges, HOM of acquirements and testing complete as
per specifications. - 160mm dia
12.116.4 Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00
kgs/sqcm working pressure with pipe fittings, wall clips etc., and making
good the wall, ceiling and floor for sanitary pipelines including cost of all m 1354.00
materials, labour charges, HOM of acquirements and testing complete as
per specifications. - 200mm dia
12.116.5 Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00
kgs/sqcm working pressure with pipe fittings, wall clips etc., and making
good the wall, ceiling and floor for sanitary pipelines including cost of all m 2075.00
materials, labour charges, HOM of acquirements and testing complete as
per specifications. - 250mm dia
Page No. 90

13.0 WATER SUPPLY WORK

Page 67 of 375
13.1 KSRB13-1.1 : Providing and fixing to wall, ceiling and floor galvanised /
mild steel tube 15mm dia nominal bore with fittings (medium grade weight
1.27 kg/mtr) B class including cost of all materials, labour charges, HOM of m 203.00
equipments and testing complete as per specifications. Specification
No.KBS 13.2.14 / 13.8
13.2 KSRB13-1.2 : Providing and fixing to wall, ceiling and floor galvanised /
mild steel tube 20mm dia nominal bore with fittings (medium grade weight
1.65 kg/mtr) B class including cost of all materials, labour charges, HOM of m 240.00
equipments and testing complete as per specifications. Specification
No.KBS 13.2.14 / 13.8
13.3 KSRB13-1.3 : Providing and fixing to wall, ceiling and floor galvanised /
mild steel tube 25mm dia nominal bore with fittings (medium grade weight
2.51kg/mtr) B class including cost of all materials, labour charges, HOM of m 311.00
equipments and testing complete as per specifications. Specification
No.KBS 13.2.14 / 13.8
13.4 KSRB13-1.4 : Providing and fixing to wall, ceiling and floor galvanised /
mild steel tube 32mm dia nominal bore with fittings (medium grade weight
3.23kg/mtr) B class including cost of all materials, labour charges, HOM of m 361.00
equipments and testing complete as per specifications. Specification
No.KBS 13.2.14 / 13.8
13.5 KSRB13-1.5 : Providing and fixing to wall, ceiling and floor galvanised /
mild steel tube 40mm dia nominal bore with fittings (medium grade weight
3.72 kg/mtr) B class including cost of all materials, labour charges, HOM of m 447.00
equipments and testing complete as per specifications. Specification
No.KBS 13.2.14 / 13.8
13.6 KSRB13-1.6 : Providing and fixing to wall, ceiling and floor galvanised /
mild steel tube 50mm dia nominal bore with fittings (medium grade weight
5.24kg/mtr) B class including cost of all materials, labour charges, HOM of m 512.00
equipments and testing complete as per specifications. Specification
No.KBS 13.2.14 / 13.8
13.7 KSRB13-2.1 : Extra for concealed pipe including painting with anticorrosive
bitumastic paint cutting chases, making good the concrete surface, and
plaster for 15mm dia nominal bore including cost of all materials, labour m 156.00
charges, HOM equipment complete as per specifications. Specification
No.KBS
13.8 KSRB13-2.2 : Extra for concealed pipe including painting with anticorrosive
bitumastic paint cutting chases making good the concrete surface and
plaster for 20mm dia nominal bore including cost of all materials, labour m 156.00
and HOM equipment complete as per specifications. Specification No.KBS

13.9 KSRB13-2.3 : Extra for concealed pipe including painting with anticorrosive
bitumastic paint, cutting chases making good the concrete surface and
plaster for 25mm dia nominal bore including cost of all materials, labour m 156.00
and HOM equipment complete as per specifications. Specification No.KBS

13.10 KSRB13-3.1: Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 15mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 144.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.11 KSRB13-3.2 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 20mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 177.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.12 KSRB13-3.3 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 25mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 250.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.13 KSRB13-3.4 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 32mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 283.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.14 KSRB13-3.5 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 40mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 356.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6

Page 68 of 375
13.15 KSRB13-3.6 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 50mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 388.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.16 KSRB13-3.7 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 65mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 596.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.17 KSRB13-3.8 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 80mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 750.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.18 KSRB13-3.9 : Providing and fixing in trenches galvanised / mild steel tubes
(medium grade) 100mm dia nominal bore with all fittings ( earth work in
trenches to be measured and paid for separately ) including cost of all m 1001.00
materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.14 / 13.6
13.19 KSRB13-3.10 : Providing and fixing in trenches galvanised / mild steel
tubes (medium grade) 150mm dia nominal bore with all fittings ( earth work
in trenches to be measured and paid for separately ) including cost of all
materials, labour charges, HOM of equipments and testing complete as per m 1494.00
specifications. Specification No.KBS 13.2.14 / 13.6

Page No. 92
13.20 KSRB13-4.1 : Making connection of G.I distribution branch with G.I main
of 25 to 40mm. nominal bore, including cutting and threading the pipes,
providing and fixing Tee, nuts, labour for all item of works, testing and Nos 483.00
HOM of equipments complete as per specifications. Specification No.KBS
13.10
13.21 KSRB13-4.2 : Making connection of G.I distribution branch with G.I main
of 50 to 85mm. and 100 to 150 nominal bore, including cutting and
threading the pipes, providing and fixing Tee, nuts, labour for all item of Nos 879.00
works, testing and HOM of equipments complete as per specifications.
Specification No.KBS 13.10
13.22 KSRB13-5 : Providing and fixing water meter with stop cock, jam nut,
socket in G.I pipe line including cutting and threading the pipe and making
long screws including cost of all materials, labour, HOM of equipments and Set 1320.00
testing complete as per specifications. Specification No.KBS 13.2.19 /
13.16
13.23 KSRB13-6.1-1 : Providing and fixing in position brass bib cock of approved
quality 15mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 190.00
No.KBS 13.2.2 / 13.3
13.24 KSRB13-6.1-2 : Providing and fixing in position brass bib cock of approved
quality 20mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 173.00
No.KBS 13.2.2 / 13.3. (P.No.91/ I.No. 13.24 of CSR 2015-16)

13.25 KSRB13-6.1-3 : Providing and fixing in position brass bib cock of approved
quality 25mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 236.00
No.KBS 13.2.2 / 13.3
13.26 KSRB13-6.2-1 : Providing and fixing in position brass stop cock of approved
quality 15mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 141.00
No.KBS 13.2.2 / 13.3
13.27 KSRB13-6.2-2 : Providing and fixing in position brass stop cock of approved
quality 20mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 141.00
No.KBS 13.2.2 / 13.3
13.28 KSRB13-6.2-3 : Providing and fixing in position brass stop cock of approved
quality 25mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 139.00
No.KBS 13.2.2 / 13.3
13.29 KSRB13-6.2-4 : Providing and fixing in position brass stop cock of approved
quality 32mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 139.00
No.KBS 13.2.2 / 13.3

Page 69 of 375
13.30 KSRB13-6.2-5 : Providing and fixing in position brass stop cock of approved
quality 40mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 140.00
No.KBS 13.2.2 / 13.3
13.31 KSRB13-6.2-6 : Providing and fixing in position brass stop cock of approved
quality 50mm nominal bore including cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification Each 138.00
No.KBS 13.2.2 / 13.3
13.32 KSRB13-6.3-1 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 15mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 272.00
as per specifications. Specification No.KBS 13.2.6 / 13.3

13.33 KSRB13-6.3-2 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 20mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 336.00
as per specifications. Specification No.KBS 13.2.6 / 13.3 (P.No. 91, I.No.
13.33 of PWD SR 2015-16)
Page No. 93
13.34 KSRB13-6.3-3 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 25mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 449.00
as per specifications. Specification No.KBS 13.2.6 / 13.3. (P.No.91/ I.No.
13.34 of CSR 2015-16)
13.35 KSRB13-6.3-4 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 32mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 830.00
as per specifications. Specification No.KBS 13.2.6 / 13.3

13.36 KSRB13-6.3-5 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 40mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 1040.00
as per specifications. Specification No.KBS 13.2.6 / 13.3 (P.No. 92, I.No.
13.36 of PWD SR 2015-16)
13.37 KSRB13-6.3-6 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 50mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 1739.00
as per specifications. Specification No.KBS 13.2.6 / 13.3. (P.No.92/ I.No.
13.37 of CSR 2015-16)
13.38 KSRB13-6.3-7 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 65mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 2103.00
as per specifications. Specification No.KBS 13.2.6 / 13.3. (P.No.92/ I.No.
13.38 of CSR 2015-16)
13.39 KSRB13-6.3-8 : Providing and fixing in position brass gate valve with C.I
wheel of approved quality ( screwed end ) 80mm nominal bore including
cost of all materials, labour and HOM of equipments with all leads complete Each 2221.00
as per specifications. Specification No.KBS 13.2.6 / 13.3

13.40 KSRB13-6.4-1 : Providing and fixing in position brass ball valve high or low
pressure with plastic float of approved quality 15mm nominal bore
including cost of all materials, labour and HOM of equipments with all Each 343.00
leads complete as per specifications. Specification No.KBS
13.41 KSRB13-6.4-2 : Providing and fixing in position brass ball valve high or low
pressure with plastic float of approved quality 20mm nominal bore
including cost of all materials, labour and HOM of equipments with all Each 359.00
leads complete as per specifications. Specification No.KBS
13.42 KSRB13-6.4-3 : Providing and fixing in position brass ball valve high or low
pressure with plastic float of approved quality 25mm nominal bore
including cost of all materials, labour and HOM of equipments with all Each 513.00
leads complete as per specifications. Specification No.KBS
13.43 KSRB13-6.5-1 : Providing and fixing in position 15mm nominal bore brass
ferrule with C.I mouth cover including boring and tapping the main, cost of
all materials, labour and HOM of equipments with all leads complete as per Each 161.00
specifications. Specification No.KBS 13.2.3 / 13.14

13.44 KSRB13-6.5-2 : Providing and fixing in position 20mm nominal bore brass
ferrule with C.I mouth cover including boring and tapping the main, cost of
all materials, labour and HOM of equipments with all leads complete as per Each 209.00
specifications. Specification No.KBS 13.2.3 / 13.14

Page 70 of 375
13.45 KSRB13-6.5-3 : Providing and fixing in position 25mm nominal bore brass
ferrule with C.I mouth cover including boring and tapping the main, cost of
all materials, labour and HOM of equipments with all leads complete as per Each 241.00
specifications. Specification No.KBS 13.2.3 / 13.14

13.46 KSRB13-6.6-1 : Providing and fixing unplasticised PVC connection pipe


with brass union 15mm nominal bore 300 mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 234.00
leads complete as per specifications. Specification No.KBS

13.47 KSRB13-6.6-2 : Providing and fixing unplasticised PVC connection pipe


with brass union 15mm nominal bore 450mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 264.00
leads complete as per specifications. Specification No.KBS. (P.No.92, I.No.
13.47 of PWD SR 2015-16)
13.48 KSRB13-6.6-3 : Providing and fixing unplasticised PVC connection pipe
with brass union 20mm nominal bore 300 mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 242.00
leads complete as per specifications. Specification No.KBS

13.49 KSRB13-6.6-4 : Providing and fixing unplasticised PVC connection pipe


with brass union 20mm nominal bore 450mm length of PVC connection
including cost of all materials, labour and HOM of equipments with all Set 246.00
leads complete as per specifications. Specification No.KBS

Page No. 94
13.50 KSRB13-6.7-1 : Providing and fixing in position chromium plated brass
shower rose with 15 or 20mm inlet 100mm dia including cost of all
materials, labour and HOM of equipments with all leads complete as per Each 707.00
specifications. Specification No.KBS 13.2.16 / 13.3
13.51 KSRB13-6.7-2 : Providing and fixing in position chromium plated brass
shower rose with 15 or 20mm inlet 150mm dia including cost of all
materials, labour and HOM of equipments with all leads complete as per Each 750.00
specifications. Specification No.KBS 13.2.16 / 13.3
13.52 KSRB13-7.1-1 : Providing and fixing in position 25mm nominal bore gun
metal non-return valve horizontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as per Nos 587.00
specifications. Specification No.KBS 13.2.10 / 13.13

13.53 KSRB13-7.1-2 : Providing and fixing in position 32mm nominal bore gun
metal non-return valve horizontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as per Nos 740.00
specifications. Specification No.KBS 13.2.10 / 13.13

13.54 KSRB13-7.1-3 : Providing and fixing in position 40mm nominal bore gun
metal non-return valve horizontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as per Each 947.00
specifications. Specification No.KBS 13.2.10 / 13.13

13.55 KSRB13-7.1-4 : Providing and fixing in position 50mm nominal bore gun
metal non-return valve horizontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as per Nos 1330.00
specifications. Specification No.KBS 13.2.10 / 13.13

13.56 KSRB13-7.1-5 : Providing and fixing in position 65mm nominal bore gun
metal non-return valve horizontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as per Nos 1728.00
specifications. Specification No.KBS 13.2.10 / 13.13

13.57 KSRB13-7.1-6 : Providing and fixing in position 80mm nominal bore gun
metal non-return valve horizontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as per Nos 2143.00
specifications. Specification No.KBS 13.2.10 / 13.13

13.58 KSRB13-7.1-7 : Providing and fixing in position 100mm nominal bore gun
metal non-return valve horizontal type of approved make including cost of
all materials, labour and HOM of equipments with all leads complete as per Nos 2403.00
specifications. Specification No.KBS 13.2.10 / 13.13

Page 71 of 375
13.59 KSRB13-7.2-1 : Providing and fixing in position 25mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos 475.00
specifications. Specification No.KBS 13.2.10 / 13.13
13.60 KSRB13-7.2-2 : Providing and fixing in position 32mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos 747.00
specifications. Specification No.KBS 13.2.10 / 13.13
13.61 KSRB13-7.2-3 : Providing and fixing in position 40mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos 903.00
specifications. Specification No.KBS 13.2.10 / 13.13
13.62 KSRB13-7.2-4 : Providing and fixing in position 50mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos 1269.00
specifications. Specification No.KBS 13.2.10 / 13.13
13.63 KSRB13-7.2-5 : Providing and fixing in position 65mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos 1579.00
specifications. Specification No.KBS 13.2.10 / 13.13
13.64 KSRB13-7.2-6 : Providing and fixing in position 80mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos 1929.00
specifications. Specification No.KBS 13.2.10 / 13.13
13.65 KSRB13-7.2-7 : Providing and fixing in position 100mm nominal bore non-
return valve vertical type of approved make including cost of all materials,
labour and HOM of equipments with all leads complete as per Nos 2198.00
specifications. Specification No.KBS 13.2.10 / 13.13
13.66 KSRB13-8.1 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 20mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor including cost of all materials, labour m 107.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.67 KSRB13-8.2 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 25mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 129.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.68 KSRB13-8.3 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 190.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.69 KSRB13-8.4 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 40mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 228.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

Page No : 95
13.70.1 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 261.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.70.2 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 63mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 297.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.70.3 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 326.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

Page 72 of 375
13.70.4 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 90mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 380.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.70.5 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 110mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 450.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.70.6 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 140mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 556.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.70.7 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density
polyethylene pipes 6.00 kgf/sq.cm working pressure 160mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 627.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.1 / 13.9

13.71 KSRB13-9.1 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 32mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 235.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9

13.72 KSRB13-9.2 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 40mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 262.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9

13.73.1 KSRB13-9.3 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 50mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 328.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9

13.73.2 KSRB13-9.4 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 63mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 372.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9

13.73.3 KSRB13-9.5 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 75mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 425.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9. (P.No. 94/ I.No. 13.73.3 of CSR
2015-16)

13.73.4 KSRB13-9.6 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 90mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 498.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9. (P.No. 94, I.No.13.73.4 of PWD SR
2015-16)

13.73.5 KSRB13-9.7 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 110mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 595.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9

Page 73 of 375
13.73.6 KSRB13-9.8 : Providing and fixing to wall, ceiling and floor high density
polyethylene pipes 6.00 kgf/sq.cm working pressure 140mm outside
diameter with special flange, compression type fittings, wall clips, making
good the wall, ceiling and floor, including cost of all materials, labour m 741.00
charges, HOM of equipments and testing complete as per specifications.
Specification No.KBS 13.2.15.2 / 13.9. (P.No. 94, I.No.13.73.5 of PWD SR
2015-16)

13.74 KSRB13-10.1 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 16mm outside diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials, m 107.00
labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.4 / 13.9

13.75 KSRB13-10.2 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 20mm outside diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials, m 107.00
labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.4 / 13.9

13.76 KSRB13-10.3 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 25mm outside diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials, m 118.00
labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.4 / 13.9

13.77 KSRB13-10.4 : Providing and fixing to wall, ceiling and floor unplasticised
PVC pipes 10.00 kgf/sq.cm working pressure 32mm outside diameter
chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials, m 129.00
labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.4 / 13.9

13.78 KSRB 13-11.1 : Providing and placing on terrace, polyethylene water


storage tanks with manhole lid and suitable locking arrangements, making
holes of suitable diameter for inlet, outlet and over flow pipes, including
cost of all materials, labour, transport charges, HOM of equipments and Nos 6828.00
testing complete as per specifications.(For 1000 litre capacity) Specification
No.KBS 13.22
Page No. 96
13.79.1 Providing and fixing gun metal wheel valve conforming to IS specification of
approved make as per directions including all lead and lift etc., complete. - Each 395.00
for 15mm dia:
13.79.2 Providing and fixing gun metal wheel valve conforming to IS specification of
approved make as per directions including all lead and lift etc., complete.- Each 414.00
for 20mm dia:
13.79.3 Providing and fixing gun metal wheel valve conforming to IS specification of
approved make as per directions including all lead and lift etc., complete.- Each 447.00
for 25mm dia:
13.79.4 Providing and fixing gun metal wheel valve conforming to IS specification of
approved make as per directions including all lead and lift etc., complete.- Each 486.00
for 32mm dia:
13.79.5 Providing and fixing gun metal wheel valve conforming to IS specification of
approved make as per directions including all lead and lift etc., complete.- Each 562.00
for 40mm dia:
13.79.6 Providing and fixing gun metal wheel valve conforming to IS specification of
approved make as per directions including all lead and lift etc., complete.- Each 734.00
for 50mm dia:
13.80 Providing gun metal pillar cocks 15mm dia of I class conforming to ISI
specifications and fixing them in position as per directions including of cost Each 242.00
of materials and fixtures and conveyance to spot.
13.81.1 Providing NP/CP waste unions conforming to ISI specifications and fixing
them in position as per directions including cost of materials, fixtures and Each 120.00
conveyance to work spot etc., complete. - for 32mm dia
13.81.2 Providing NP/CP waste unions conforming to ISI specifications and fixing
them in position as per directions including cost of materials, fixtures and Each 160.00
conveyance to work spot etc., complete.- for 40mm dia:
13.81.3 Providing NP/CP waste unions conforming to ISI specifications and fixing
them in position as per directions including cost of materials, fixtures and Each 210.00
conveyance to work spot etc., complete.- for 50mm dia:

Page 74 of 375
13.82.1 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)
Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 179.00
tees, reducers, couplers & connectors etc., with clamps at 1.00 meter
spacing, cutting & making good the walls etc., including testing complete as
required. (Internal work) Pipes exposed on wall - 1216(16 mm OD) Pipe

13.82.2 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 214.00
tees, reducers, couplers & connectors etc., with clamps at 1.00 meter
spacing, cutting & making good the walls etc., including testing complete as
required. (Internal work) Pipes exposed on wall - 1620(20mm OD) pipe

13.82.3 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 254.00
tees, reducers, couplers & connectors etc., with clamps at 1.00 meter
spacing, cutting & making good the walls etc., including testing complete as
required. (Internal work) Pipes exposed on wall - 2025(25mm OD) pipe

13.82.4 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 357.00
tees, reducers, couplers & connectors etc., with clamps at 1.00 meter
spacing, cutting & making good the walls etc., including testing complete as
required. (Internal work) Pipes exposed on wall - 2532(32mm OD) pipe

13.82.5 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 510.00
tees, reducers, couplers & connectors etc., with clamps at 1.00 meter
spacing, cutting & making good the walls etc., including testing complete as
required. (Internal work) Pipes exposed on wall - 3240 (40mm OD) pipe

13.82.6 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 589.00
tees, reducers, couplers & connectors etc., with clamps at 1.00 meter
spacing, cutting & making good the walls etc., including testing complete as
required. (Internal work) Pipes exposed on wall - 4050 (50mm OD) pipe

Page No : 97
13.83.1 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)
Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows,
tees, reducers, couplers & connectors etc. with cement tacking at 1.00 m 265.00
meter spacing, and every fitting, cutting & making good the walls etc.,
including testing complete as required. (Internal work) Concealed piping
with cutting chases & making good walls etc., - 1216(16 mm OD) Pipe

Page 75 of 375
13.83.2 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)
Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows,
tees, reducers, couplers & connectors etc. with cement tacking at 1.00 m 305.00
meter spacing, and every fitting, cutting & making good the walls etc.,
including testing complete as required. (Internal work) Concealed piping
with cutting chases & making good walls etc., - 1620(20mm OD) pipe

13.83.3 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows,
tees, reducers, couplers & connectors etc. with cement tacking at 1.00 m 350.00
meter spacing, and every fitting, cutting & making good the walls etc.,
including testing complete as required. (Internal work) Concealed piping
with cutting chases & making good walls etc., - 2025(25mm OD) pipe

13.83.4 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows,
tees, reducers, couplers & connectors etc. with cement tacking at 1.00 m 466.00
meter spacing, and every fitting, cutting & making good the walls etc.,
including testing complete as required. (Internal work) Concealed piping
with cutting chases & making good walls etc., - 2532(32mm OD) pipe

13.83.5 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows,
tees, reducers, couplers & connectors etc. with cement tacking at 1.00 m 648.00
meter spacing, and every fitting, cutting & making good the walls etc.,
including testing complete as required. (Internal work) Concealed piping
with cutting chases & making good walls etc., - 3240 (40mm OD) pipe

13.83.6 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows,
tees, reducers, couplers & connectors etc. with cement tacking at 1.00 m 751.00
meter spacing, and every fitting, cutting & making good the walls etc.,
including testing complete as required. (Internal work) Concealed piping
with cutting chases & making good walls etc., - 4050 (50mm OD) pipe

13.84.1 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows,
tees, reducers, couplers & connectors etc. with tranching & refilling upto m 171.00
1.00 meter depth including testing complete as required. (External work)
Pipe in trenches including excavation & refilling etc.,
- 1216 (16mm OD) pipe

13.84.2 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 198.00
tees, reducers, couplers & connectors etc. with tranching & refilling upto
1.00 meter depth including testing complete as required. (External work)
Pipe in trenches including excavation & refilling etc., - 1620(20mm OD)
pipe

Page 76 of 375
13.84.3 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE)
Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 229.00
tees, reducers, couplers & connectors etc. with tranching & refilling upto
1.00 meter depth including testing complete as required. (External work)
Pipe in trenches including excavation & refilling etc., - 2025 (25mm OD)
pipe

13.84.4 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 316.00
tees, reducers, couplers & connectors etc. with tranching & refilling upto
1.00 meter depth including testing complete as required. (External work)
Pipe in trenches including excavation & refilling etc., - 2532 (32mm OD)
pipe

13.84.5 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 448.00
tees, reducers, couplers & connectors etc. with tranching & refilling upto
1.00 meter depth including testing complete as required. (External work)
Pipe in trenches including excavation & refilling etc., - 3240 (40mm OD)
pipe

13.84.6 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE)


Composite Pressure Pipes conforming to IS 15450 duly “ISI” marked, U.V.
stabalized with Carbon black for hot & cold water supply, capable to
withstand temperature upto 80°C including all special composite fittings
(engineering plastic blend and brass inserts wherever required.) e.g. elbows, m 527.00
tees, reducers, couplers & connectors etc. with tranching & refilling upto
1.00 meter depth including testing complete as required. (External work)
Pipe in trenches including excavation & refilling etc., - 4050 (50mm OD)
pipe

13.85.1 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and m 130.00
fittings with one step CPVC solvent cement and testing of joints complete.
(internal work exposed on wall) - 15mm nominal OD pipes

13.85.2 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and m 157.00
fittings with one step CPVC solvent cement and testing of joints complete.
(internal work exposed on wall) - 20mm nominal OD pipes

13.85.3 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and m 196.00
fittings with one step CPVC solvent cement and testing of joints complete.
(internal work exposed on wall) - 25mm nominal OD pipes. (P.No. 96/I.No.
13.85.3 of CSR 2015-16)

13.85.4 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and m 254.00
fittings with one step CPVC solvent cement and testing of joints complete.
(internal work exposed on wall) - 32mm nominal OD pipes

13.85.5 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and m 337.00
fittings with one step CPVC solvent cement and testing of joints complete.
(internal work exposed on wall) - 40mm nominal OD pipes

Page 77 of 375
13.85.6 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and m 465.00
fittings with one step CPVC solvent cement and testing of joints complete.
(internal work exposed on wall) - 50mm nominal OD pipes. (P.No. 96/I.No.
13.85.6 of CSR 2015-16)

Page No : 98
13.86.1 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPVC solvent cement & the cost of cutting chases & m 206.00
making good the same including testing of joints complete. (Concealed work
including cutting chases and good the walls etc.) - 15mm nominal OD pipes

13.86.2 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPVC solvent cement & the cost of cutting chases & m 235.00
making good the same including testing of joints complete. (Concealed work
including cutting chases and good the walls etc.) - 20mm nominal OD
pipes. (P.No.96, I.No. 13.86.2 of PWD SR 2015-16)

13.86.3 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPVC solvent cement & the cost of cutting chases & m 293.00
making good the same including testing of joints complete. (Concealed work
including cutting chases and good the walls etc.) - 25mm nominal OD pipes

13.86.4 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778, having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings including fixing
the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and
fittings with one step CPVC solvent cement & the cost of cutting chases & m 374.00
making good the same including testing of joints complete. (Concealed work
including cutting chases and good the walls etc.) - 32mm nominal OD pipes

13.87.1 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 126.00
refilling & testing of joints complete. (external work). - 15mm nominal OD
pipes

13.87.2 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 146.00
refilling & testing of joints complete. (external work). - 20mm nominal OD
pipes

13.87.3 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 179.00
refilling & testing of joints complete. (external work). - 25mm nominal OD
pipes

13.87.4 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 226.00
refilling & testing of joints complete. (external work). - 32mm nominal OD
pipes

13.87.5 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 292.00
refilling & testing of joints complete. (external work). - 40mm nominal OD
pipes

Page 78 of 375
13.87.6 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 432.00
refilling & testing of joints complete. (external work). - 50mm nominal OD
pipes

13.87.7 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 1410.00
refilling & testing of joints complete. (external work). - 62.50mm nominal
OD pipes

13.87.8 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 1800.00
refilling & testing of joints complete. (external work). - 75mm nominal OD
pipes. (P.No. 97/ I.No. 13.87.8 of CSR 2015-16)

13.87.9 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 2450.00
refilling & testing of joints complete. (external work). - 100mm nominal OD
pipes

13.87.10 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes
conforming to IS 15778 having thermal stability for hot and cold water
supply including all CPVC plain and brass threaded fittings, this includes
jointing of pipes and fittings with one step solvent cement, trenching, m 4250.00
refilling & testing of joints complete. (external work). - 150mm nominal OD
pipes

13.88 Providing and fixing polished granite sink of size 60cms x 90cms of 23cm
thick, the sink portion shall be 15cm in depth of shapes oval / round /
square over brick masonry in cement mortar 1:6 including cost and
conveyance of all materials, labour for all items of work, HOM of equipment
with all lead and lift, loading and unloading, transportation charges and all Each 6563.00
other incidental charges etc., complete as per specification and directions of
the Engineer-in-charge of the work.

13.89 Providing and fixing polished granite sink of size 60cms x 75cms of 23cm
thick, the sink portion shall be 15cm in depth of shapes oval / round /
square over brick masonry in cement mortar 1:6 including cost and
conveyance of all materials, labour for all items of work, HOM of equipment
with all lead and lift, loading and unloading, transportation charges and all Each 5574.00
other incidental charges etc., complete as per specification and directions of
the Engineer-in-charge of the work.

Page No : 99
13.90 Providing and fixing polished granite sink of size 60cms x 60cms of 23cm
thick, the sink portion shall be 15cm in depth of shapes oval / round /
square over brick masonry in cement mortar 1:6 including cost and
conveyance of all materials, labour for all items of work, HOM of equipment
with all lead and lift, loading and unloading, transportation charges and all Each 4586.00
other incidental charges etc., complete as per specification and directions of
the Engineer-in-charge of the work.

13.91 Providing and Fixing Stainless Steel sink of sizes upto 60cms x 45cms in
20mm thick granite slab of by cutting required thickness and width of
grooves and fixing using adhesives etc., complete including cost and
conveyance of all materials, labour for all items of work, HOM of equipment Each 5437.00
with all lead and lift, loading and unloading, transportation charges and all
other incidental charges etc., complete as per specification and directions of
the Engineer-in-charge of the work.

13.92.1 Cutting granite slab upto 40mm thick and required width of grooves for
fixing Stainless steel sink upto 60cm x 45 cms and fixing using adhesives. No 1047.00

13.92.2 Cutting granite slab upto 40mm thick and required width of grooves for
fixing Stainless steel sink above 60cm x 45 cms and fixing using adhesives. No 1570.00

Page 79 of 375
13.93.1 Providing and fixing concealed UVstabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
incluiding brass threaded polypropelene random fittings including chasing m 210.00
the walls. Internal Plumbing - for concealed fitting - 20mm pipe outer dia (3
layer)
13.93.2 Providing and fixing concealed UVstabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
incluiding brass threaded polypropelene random fittings including chasing m 260.00
the walls. Internal Plumbing - for concealed fitting - 25mm pipe outer dia (3
layer)
13.93.3 Providing and fixing concealed UVstabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
incluiding brass threaded polypropelene random fittings including chasing m 330.00
the walls. Internal Plumbing - for concealed fitting - 32mm pipe outer dia (3
layer)
13.94.1 Providing and fixing concealed UV stabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 compete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 140.00
the walls. Internal Plumbing - for exposed on wall - 20mm pipe
outer dia (3 layer)
13.94.2 Providing and fixing concealed UV stabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 compete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 180.00
the walls. Internal Plumbing - for exposed on wall - 25mm pipe
outer dia (3 layer)
13.94.3 Providing and fixing concealed UV stabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 compete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 250.00
the walls. Internal Plumbing - for exposed on wall - 32mm pipe
outer dia (3 layer)
13.94.4 Providing and fixing concealed UV stabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 compete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 350.00
the walls. Internal Plumbing - for exposed on wall - 40mm pipe
outer dia (3 layer)
13.94.5 Providing and fixing concealed UV stabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 compete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 500.00
the walls. Internal Plumbing - for exposed on wall - 50mm pipe
outer dia (3 layer)
Page No : 100
13.95.1 Providing and fixing concealed UV stabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 130.00
the walls. External plumbing - 20mm pipe outer dia (3 layer)

13.95.2 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 180.00
the walls. External plumbing -25mm pipe outer dia (3 layer)

13.95.3 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 220.00
the walls. External plumbing - 32mm pipe outer dia (3 layer)

13.95.4 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 300.00
the walls. External plumbing - 40mm pipe outer dia (3 layer)

13.95.5 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 550.00
the walls. External plumbing - 50mm pipe outer dia (3 layer)

13.95.6 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 670.00
the walls. External plumbing - 63mm pipe outer dia (3 layer)

Page 80 of 375
13.95.7 Providing and fixing concealed UV stabilised and antimicrobial fusion 3
layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 800.00
the walls. External plumbing - 75mm pipe outer dia (3 layer)

13.95.8 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 1200.00
the walls. External plumbing - 90mm pipe outer dia (3 layer)

13.95.9 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 1320.00
the walls. External plumbing - 110mm pipe outer dia (3 layer)

13.95.10 Providing and fixing concealed UV stabilised and antimicrobial fusion 3


layer PP-R pipes confirming to DIN 8077 complete with PP-R plain fittings
including brass threaded polypropelene random fittings including chasing m 2260.00
the walls. External plumbing - 160mm pipe outer dia (3 layer)

Note : KSRB 13-11 : Polytheylene tanks


1 These tanks shall be ready made/manufactured with following materials

i) HDPE : High Density poly-ethylene


ii) LDPE : Low Density poly-ethylene
iii) LLDPE : Linear low density poly-ethylene
2 Tanks shall be anchored properly depending upon location
3 Fittings checknuts etc., shall be paid separately
4 Tanks shall be anchored properly depending upon location
5 Tanks are available in sizes 200 to 20000 litres
6 Add 15% extra for itnernal water supply items.
Page No. 101

14.0 14.FLOORING

14.1 KSRB 14.1 : Providing and laying flooring with burnt stone slabs 10 cms
thick, rough chistle dressed on sand bed 7.5 cms to 8 cms thick and
pointed with cement mortar 1:3, , including cost of materials, labour, Sqm 1148.00
curing complete as per specifications. Specification No. KBS 14.26

14.2 KSRB 14.2 : Providing and laying flooring with burnt stone slabs 10 cms
thick rough chistle dressed on cement mortar bed 1:6, 25 mm thick, and
pointed with cement mortar 1:3, , including cost of materials, labour, Sqm 1112.00
curing complete as per specifications. Specification No. KBS 14.26

14.3 KSRB 14.3 : Providing and laying flooring and steps machine cut granite
slabs 40mm thick on cement mortar bed 1:6, 25 mm thick, and pointed
with cement mortar 1:3 over existing cement concrete bed , including cost Sqm 2427.00
of materials, labour, curing complete as per specifications. Specification No.
KBS 14.26
14.4 KSRB 14.4 : Providing and laying flooring and steps fine dressed granite
stone slabs 40 mm thick on cement mortar bed 1:6, 25 mm thick, and
pointed with cement mortar 1:3 over existing cement concrete bed , Sqm 3241.00
including cost of materials, labour, curing complete as per specifications.
Specification No. KBS 14.26
14.5 KSRB 14.5 : Providing and laying flooring and steps fine machine polished
granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick,
and joints finished with cement mortar 1:3 over existing cement concrete Sqm 1184.00
bed , including cost of materials, labour, curing complete as per
specifications. Specification No. KBS 14.26
14.6 KSRB 14.6-1: Providing and laying heavy duty cobble stones 60mm thick
interlock pavers, using cement and course sand for manufacture of blocks
of approved size, shape and colour with a minimum compressive strength of
281 kg per sqm over 50mm thick sand bed (average thickness ) and
compacting with plate vibrator having 3 tons compaction force thereby
forcing part of sand underneath to come up in between joints, final Sqm 1053.00
compaction of paver surface joints into its final level, including cost of
materials, labour and HOM of machineries complete as per specifications.
Specification No. KBS. (P.No. 101, I.No. 14.6 of CSR 2015-16)

Page 81 of 375
14.7 KSRB 14.6-2 :Providing and laying heavy duty cobble stones 75mm thick
interlock pavers, using cement and course sand for manufacture of blocks
of approved size, shape and colour with a minimum compressive strength of
281 kg per sqm over 50mm thick sand bed (average thickness ) and
compacting with plate vibrator having 3 tons compaction force thereby
forcing part of sand underneath to come up in between joints, final Sqm 1110.00
compaction of paver surface joints into its final level, including cost of
materials, labour and HOM of machineries complete as per specifications.
Specification No. KBS (P.No. 101, I.No. 14.7 of CSR 2015-16)

14.8 KSRB 14.7-1: Providing and laying flooring with M15 cement concrete 40
mm thick using broken granite 20mm and down size laid to line and level
in one layer and finish with a floating coat of neat cement , including cost of Sqm 349.00
materials, labour, curing, complete as per specifications. Specification No.
KBS 14.3
Page No. 103
14.9 KSRB 14.7-2 : Providing and laying red oxide flooring 40 mm thick, with an
under layer of 30mm thick M-15 cement concrete, using broken granite
metal of 12.5mm nominal size and top layer of 10mm thick plaster with 1:3
cement mortar mixed with red oxide ( using 3.5 kg of red oxide per 50 kg of
cement ) finished with floating coat of neat cement mixed with red oxide Sqm 665.00
( mix of same proportion ) , including cost of materials, labour, curing,
complete as per specifications. Specification No. KBS 14.3

14.10 KSRB 14.7-3 : Providing and laying flooring 40 mm thick, with an under
layer of 30mm thick M-15 cement concrete, using broken granite metal of
12.5mm nominal size and top layer of 10mm thick plaster with cement
mortar 1:3, finished with floating coat of neat cement , including cost of Sqm 608.00
materials, labour, curing, complete as per specifications. Specification No.
KBS 14.3. (P.No. 102, I.No. 14.10 of CSR 2015-16)

14.11 KSRB 14.7-4 : Extra for making chequers of approved pattern on cement
concrete floor, steps, landings, pavements , including cost of labour Sqm 36.00
complete as per specifications. Specification No. KBS
14.12 KSRB 14.8-1: Providing and laying linolium covering to floors plain or
coloured 3.2mm thick sheet / tiles laid with an approved adhesive on sub
floor stretching, cutting and fixing complete , including cost of materials, Sqm 408.00
labour, complete as per specifications. Specification No. KBS 14.37.7

14.13 KSRB 14.9-1: Providing and laying M-15 cement concrete flooring, 50 mm
thick with metallic concrete hardner toping, under layer of 35mm thick m-
15 cement concrete using broken granite metal of 20mm and down size,
and top layer 50mm thick of metallic cement hardner consisting of mix 1:2 (
1 cement hardner mix : 2 granite metal 10mm nominal size ) by volume,
with which metallic hardening compound of approved quality mix in the Sqm 631.00
ratio of 4:1 ( 4 part of cement and 1 part of metallic floor hardening
compound of approved quality by wt) , including finishing cost of materials,
labour, curing, complete as per specifications Specification No. KBS 14.4

14.14 KSRB 14.9-2 : Providing and laying M-15 cement concrete flooring 60 mm
thick with metallic concrete hardner toping, under layer of 45mm thick M-
15 cement concrete using broken granite metal of 20mm and down size and
top layer of 15mm thick metallic cement hardner consisting of mix 1:2 ( 1
cement hardner mix : 2 granite metal 10mm nominal size ) by volume, with
metalic hardening compound of approved quality mix in the ratio of 4:1 ( 4 Sqm 701.00
part of cement = 1 part of metallic floor hardening compound of approved
quality by wt ) , including finishing, cost of materials, labour, curing,
complete as per specifications. Specification No. KBS 14.4

Page No. 104


14.15 KSRB 14.10-1: Flooring with 25mm to 40mm thick polished tandur blue
stone slabs using cement mortar 1:6, 25mm thick over existing cement
concrete bed or top of roof laid to line and level and jointed with cement
slurry mixed with pigment to match the shade of the slab, , including cost Sqm 1254.00
of materials, labour, curing, polishing complete as per specifications.
Specification No. KBS

14.16 KSRB 14.10-2: Flooring with 25mm to 40mm thick polished shahabad
slabs using cement mortar 1:6, 25mm thick over existing cement concrete
bed or top of roof laid to line and level and jointed with cement slurry mixed
with pigment to match the shade of the slab, , including cost of materials, Sqm 1380.00
labour, curing, polishing complete as per specifications. Specification No.
KBS

Page 82 of 375
14.17 KSRB 14.10-3: Providing flooring with 25mm to 40mm thick polished
Cadapa slabs using cement mortar 1:6, 25mm thick over existing cement
concrete bed or top of roof laid to line and level and jointed with cement
slurry mixed with pigment to match the shade of the slab, including cost of Sqm 1288.00
materials, labour, curing, polishing complete as per specifications.
Specification No. KBS

14.18 KSRB 14.11-1: Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement concrete M-15 with stone aggregate
12mm and down size, and top layer 12mm thick with dark shade pigment
with ordinary cement in top layer only using white, black, chacolate, yellow
or baroda green marble chips of size from 7 to 10 nominal size laid in
Sqm 1460.00
cement marble powder mix 3:1 ( 3 cement : 1 marble powder by weight ) in
proportion of 4:7 ( 4 cement marble powder mix : 7 marble chips by
volume ) curing polishing oxalic acid wash, wax polish , including cost of
materials, labour, complete as per specifications. Specification No. KBS
14.8

14.19 KSRB 14.11-2 : Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring, rubbed and polished to granolithic finish with
under layer of 28mm thick cement cocrete M-15 with stone aggregate
12mm and down size , and top layer 12mm thick with light shade pigment
with white cement in top layer only using white, black, chacolate, yellow or
baroda green marble chips of size from 7 to 10 nominal size laid in cement
Sqm 1572.00
marble stone mixed 3:1 ( 3 cement : 1 marble powder by weight ) in
proportion of 4:7 ( 4 cement marble powder mix : 7 marble chips by
volume ) curing polishing oxalic acid wash, wax polish , including cost of
materials, labour, complete as per specifications. Specification No. KBS
14.8

14.20 KSRB 14.11-3 : Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips flooring rubbed and polished to granolithic finish with
under layer of 28mm thick cement cocrete M-15 with stone aggregate
12mm and down size, and top layer 12mm thick with medium shade
pigment with approximately 50% white cement and 50% ordinary cement in
top layer only using white, black, chacolate, yellow or baroda green marble
chips of size from 7 to 10 nominal size laid in cement marble stone mixed Sqm 1493.00
3:1 ( 3 cement : 1 marble powder by weight ) in proportion of 4:7 ( 4 cement
marble powder mix : 7 marble chips by volume ) curing polishing oxalic
acid wash, wax polishing, including cost of materials, labour, complete as
per specifications. Specification No. KBS 14.8

Page No. 105


14.21 KSRB 14.11-4 : Providing mosaic flooring with cast-in-situ 40mm thick
using marble chips and polished to granolithic finish with under layer of
28mm thick cement concrete M-15 with stone aggregate 12mm and down
size , and top layer 12mm thick with white cement without any pigment in
top layer only using white, black, chacolate, yellow or baroda green marble
chips of size from 7 to 10 nominal size laid in cement marble powder mix
Sqm 1545.00
3:1 ( 3 cement : 1 marble powder by weight ) in proportion of 4:7 ( 4 cement
marble powder mix : 7 marble chips by volume ) curing, polishing oxalic
acid wash, wax polish , including cost of materials, labour, complete as per
specifications. Specification No. KBS 14.8

14.22 KSRB 14.11-5 :Extra for providing and fixing aluminium strips 40 mm wide
and 1.5mm thick painted with a protective coat of bitumen for joints of
mosaic floors, including cost of materials, labour, curing, complete as per m 40.00
specifications. Specification No. KBS
14.23 KSRB 14.11-6 :Extra for providing and fixing glass strips 40 mm wide and
4mm thick for joints of mosaic floors , including cost of materials, labour, m 49.00
curing, complete as per specifications. Specification No. KBS
14.24 KSRB 14.12-1: Providing mosaic tiles flooring with precast grey colour
mosaic tiles 20mm thick using marble chips of approved colour 7 to 10
nominal size laid in floors and landings on a bed of 25mm thick cement
mortar 1:6, mix, jointed with neat cement slurry mix with pigment to match
the shade of tiles curing, rubbing, polishing, oxalic acid wash, wax polish , Sqm 699.00
including cost of materials, labour, HOM of machinary complete as per
specifications. Specification No. KBS 14.11

Page 83 of 375
14.25 KSRB 14.12-2: Providing mosaic tiles flooring with precast light shade
pigment with white cement mosaic tiles 20mm thick using marble chips of
approved colour 7 to 10 nominal size laid in floors and landings on a bed of
25mm thick cement mortar 1:6, mix, jointed with neat cement slurry mix
with pigment to match the shade of tiles, curing. rubbing, polishing, oxalic Sqm 805.00
acid wash, wax polish, including cost of materials, labour, HOM of
machinary complete as per specifications. Specification No. KBS 14.11

14.26 KSRB 14.12-3 : Providing mosaic tiles flooring with precast medium shade
pigment using 50% white cement and 50% ordinary cement mosaic tiles
20mm thick using marble chips of approved colour 7 to 10 nominal size
laid in floors and landings on a bed of 25mm thick average thickness of
cement mortar 1:6, mix, jointed with neat cement slurry mix with pigment Sqm 648.00
to match the shade of tiles, curing, rubbing, polishing, oxalic acid wash,
wax polish , including cost of materials, labour, HOM of machinary
complete as per specifications.

Page No. 106


14.27 KSRB 14.12-4 : Providing mosaic tiles flooring with white precast cement
mosaic tiles 20mm thick using marble chips of 7 to 10 nominal size laid in
floors and landings on a bed of 25mm thick average thickness of cement
mortar 1:6, mix, jointed with neat cement slurry mix with pigment to match Sqm 773.00
the shade of tiles, curing, rubbing, polishing, oxalic acid wash, wax polish ,
including cost of materials, labour, HOM of machinary complete as per
specifications.

14.28 KSRB 14.13-1: Providing precast chequered mosaic tiles dark shade using
ordinary grey cement for steps and flooring, with precast 20mm thick,
using marble chips of 7 to 10 nominal size laid in floors, steps and landings
on a bed of 12mm thick cement mortar 1:3 mix, and jointed with neat Sqm 1070.00
cement slurry mixed with pigment to match the shade of tiles, curing,
rubbing, polishing, oxalic acid wash, wax polish , including cost of
materials, labour, complete as per specifications.

14.29 KSRB 14.13-2: Providing precast chequered mosaic tiles light shade using
white cement for steps and flooring, 20mm thick, using marble chips of 7 to
10 nominal size laid in floors, steps and landings on a bed of 12mm thick
cement mortar 1:3 mix, and jointed with neat cement slurry mixed with
pigment to match the shade of tiles curing, rubbing, polishing, oxalic acid Sqm 1173.00
wash, wax polish , including cost of materials, labour, complete as per
specifications. Specification No. KBS 14.13, 14.14

14.30 KSRB 14.13-3: Providing precast chequered mosaic tiles medium shade
pigment using 50% white cement and 50% ordinary cement for steps and
flooring 20mm thick using marble chips of 7 to 10 nominal size laid on a
bed of 12mm thick cement mortar 1:3 mix, and jointed with neat cement
slurry mixed with pigment to match the shade of tiles curing, rubbing, Sqm 1134.00
polishing, oxalic acid wash, wax polish , including cost of materials, labour,
complete as per specifications. Specification No. KBS 14.13, 14.14

14.31 KSRB 14.13-4: Providing precast chequered mosaic tiles white colour for
steps and flooring, 20mm thick, using marble chips of 7 to 10 nominal size
laid on a bed of 12mm thick cement mortar 1:3 mix, and jointed with neat
cement slurry mixed with pigment to match the shade of tiles rubbing, Sqm 1238.00
polishing, oxalic acid wash, wax polish, including cost of materials, labour,
curing, complete as per specifications. Specification No. KBS 14.13, 14.14

Page No. 107


14.36.1 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for
flooring, treads of steps and landings laid on a bed of 12mm thick, cement
mortar 1:3 mix, flush pointing with white cement using colour pigment , Sqm 1124.00
including cost of materials, labour, curing, complete as per specifications. -
for Ceramic Tiles of size 15x15cms 6mm thick
14.36.2 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for
flooring, treads of steps and landings laid on a bed of 12mm thick, cement
mortar 1:3 mix, flush pointing with white cement using colour pigment ,
including cost of materials, labour, curing, complete as per specifications. - Sqm 1210.00
for Ceramic Tiles of size 30x30cms 6mm thick. (P.No.106, I.No. 14.36.2 of
PWD SR 2015-16)

14.36.3 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for
flooring, treads of steps and landings laid on a bed of 12mm thick, cement
mortar 1:3 mix, flush pointing with white cement using colour pigment ,
including cost of materials, labour, curing, complete as per specifications. - Sqm 1348.00
for Ceramic Tiles 400 x 400mm on a bed of 20mm thick

Page 84 of 375
14.36.4 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for
flooring, treads of steps and landings laid on a bed of 12mm thick, cement
mortar 1:3 mix, flush pointing with white cement using colour pigment ,
including cost of materials, labour, curing, complete as per specifications. - Sqm 1348.00
for Ceramic tiles 30cm x 60cm 6mm thick on a bed of 20mm thick

14.37 KSRB 14.15-1: Providing marble slab flooring 20mm thick with edges of
slab machine cut, for flooring, treads of steps and landings laid on a bed of
25mm thick cement mortar 1:6, mix, to line and level, jointed with cement
slurry curing, rubbing, polishing complete finishIing with flush pointing
using white cement, including cost of materials, HOM of machineries, Sqm 3582.00
labour, curing, complete as per specifications. Note : While preparing
analysis the quality of marble slab should be clearly noted namely white
marble, adanga marble, makrana etc., and also size of slab should be noted
clearly. Specification No. KBS 14.18

14.38 KSRB 14-16.1 : Providing skirting upto 30 cms. height with cement mortar
1:3 finished with a floating coat of neat cement including rounding off
junctions floor, overall 15 mm thick including cost of materials, labour, Sqm 323.00
complete as per specifications. Specification No.KBS 14.5

14.39 KSRB 14-16.2 : Providing red oxide skirting upto 30 cms. height with
cement mortar 1:3 including rounding off junctions with floor, finished
overall 15 mm thick, top portion 5mm thick mixed with red oxide and a
floating coat of neat cement using 3.5kg of red oxide of iron per 50 kg of Sqm 341.00
cement including cost of materials, labour, complete as per specifications.
Specification No.KBS 14.5

14.40 KSRB 14-17.1 : Providing skirting, dado, rises of steps with white glazed
tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white
cement slurry over rough plaster surface ( excluding cost of rough plastered
surface which should be measured and paid separately) using glazed tiles of Sqm 1168.00
approved make and size including cost of materials, labour, complete as per
specifications. Specification No.KBS 14.16, 14.17

14.41.1 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed
tiles on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over rough plaster surface ( excluding cost of rough plastered surface
which should be measured and paid separately) using glazed tiles of Sqm 1271.00
approved make and size including cost of materials, labour, complete as per
specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles
15x15 cms 6mm thick

14.41.2 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed
tiles on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over rough plaster surface ( excluding cost of rough plastered surface
which should be measured and paid separately) using glazed tiles of
approved make and size including cost of materials, labour, complete as per Sqm 1632.00
specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles
30x60 cms 6mm thick with border of size 30 x 10 cms. (P.No.106, I.No.
14.41.2 of PWD SR 2015-16)

14.41.3 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed
tiles on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over rough plaster surface ( excluding cost of rough plastered surface
which should be measured and paid separately) using glazed tiles of
approved make and size including cost of materials, labour, complete as per Sqm 1275.00
specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles
30x45 cms 6mm thick with border of size 30 x 10 cms.

Page No. 108


14.42 KSRB 14-18.1 : Providing skirting, dado, rises of steps with marble slabs
not exceeding 30 cms. height on 10 cms. thick cement mortar 1:3 and
jointed with white cement slurry over rough plaster surface (excluding cost
of rough plastered which should be measured and paid separately ) using Sqm 3868.00
marble slab with machine cut edges upto 25cms. thick including cost of
materials, labour, complete as per specifications. Specification No.KBS
14.19

14.43 Providing and fixing Special make glazed Vitrified tiles (Granomite finish) of
approved make, quality and colour of size 600x600x10mm thick fixed on
existing flooring with a special roffe adhesive for flooring and skirting etc.,
complete including providing spears at required interval and removing Sqm 1099.00
stains etc., complete. (P.No. 107, I.No. 14.43 of SR 2015-16).

Page 85 of 375
14.44 Providing flooring with 60 cms.x 60 cms. size Vitrified glazed tiles of
approved quality & make, fixed on top of existing flooring fixed with suitable
adhesive, including cutting the tiles to the required size and fixing etc., Sqm 1035.00
complete.
14.45 Providing vitrified tiles 60 x 60cms of approved make, shade and size for
flooring laid on a bed of 12mm thick cement mortar 1:3 mix, flush pointing
with white cement using colour pigment, including cost of materials, Sqm 976.00
labour, curing complete as per specification.
14.45.1 Providing vitrified tiles 90 x 90cms of approved make, shade and size for
flooring laid on a bed of 12mm thick cement mortar 1:3 mix, flush pointing
with white cement using colour pigment, including cost of materials, Sqm 1137.00
labour, curing complete as per specification.
14.46 Providing and laying pattern flooring for staircase treads and risers using
the combination of 20mm thick ruby red granite @ 66%,20 mm thick grey
granite @ 20%, 20mm thick, 20mm thick black granite 14%. The granite
materials are laid on existing bed of CM 1:3 20mm thick pointed with Sqm 7194.00
colour pigment, including full rounding for nosing, flaming the ruby red
granite for 50 mm wide curing etc., complete as per specification. (P.No.
107, I.No. 14.46 of PWD SR 2015-16)

14.47.1 Providing and laying flooring using prepolished, water cut/gang saw
19mm thick granite laid over bed of 20mm thick 1:4 cm & jointed with
neat cement slurry mixed with pigment to mach shade of granite slabs
including laying POP on finished surface and cleaning the surface,
including the cost of all materials and labours etc., complete as per
specifications. - using silver grey granite / Multy Red / Ruby Red / Sqm 2739.00
Black / HassanGreen Granite of width not less than 1200mm
(P.No.107, I.No.14.47.1 of PWD SR 2015-16)

Page No : 109
14.47.2 Providing and laying flooring using prepolished, water cut/gang saw
19mm thick granite laid over bed of 20mm thick 1:4 cm & jointed with
neat cement slurry mixed with pigment to mach shade of granite slabs
including laying POP on finished surface and cleaning the surface,
including the cost of all materials and labours etc., complete as per Sqm 2408.00
specifications. - using silver grey granite / Multy Red / Ruby Red /
Black / HassanGreen Granite of width not less than 900mm

14.47.3 Providing and laying flooring using prepolished, water cut/gang saw
19mm thick granite laid over bed of 20mm thick 1:4 cm & jointed with
neat cement slurry mixed with pigment to mach shade of granite slabs
including laying POP on finished surface and cleaning the surface, Sqm 1400.00
including the cost of all materials and labours etc., complete as per
specifications. - using 10mm thick silver grey granite / Multy Red /
Ruby Red/ Black / Hassan Green Granite tiles

14.47.4 Providing and laying flooring using prepolished, water cut/gang saw
19mm thick granite laid over bed of 20mm thick 1:4 cm & jointed with
neat cement slurry mixed with pigment to mach shade of granite slabs
including laying POP on finished surface and cleaning the surface, Sqm 2738.00
including the cost of all materials and labours etc., complete as per
specifications. - using 19mm thick Raw Silk / Black Pearl granite of
width not less than 1200 mm

14.47.5 Providing and laying flooring using prepolished, water cut/gang saw
19mm thick granite laid over bed of 20mm thick 1:4 cm & jointed with
neat cement slurry mixed with pigment to mach shade of granite slabs
including laying POP on finished surface and cleaning the surface, Sqm 2379.00
including the cost of all materials and labours etc., complete as per
specifications. - using 19mm thick Raw Silk / Black Pearl granite of
width not less than 900 mm

14.48.1 Providing and laying flooring for corridors/lobbies using combination of


pre polished 19 mm thick water cut/gang saw Grey Granite, Black
Granite, and strips of 50mm wide pre flamed grey granite using pre
polished grey granite 19mm thick 76%, Pre polished black granite 19mm
thick @ 2% and preflamed 19mm thick grey granite @22% over existing Sqm 2621.00
cement concrete bed in CM 1:4 average 20mm thick pointed with white
cement/colour pigment etc., complete. - using 19mm thick granite width
not less than 1200mm (P.No.108, I.No.14.48.1 of PWD SR 2016-17)

Page 86 of 375
14.48.2 Providing and laying flooring for corridors/lobbies using combination of
pre polished 19 mm thick water cut/gang saw Grey Granite, Black
Granite, and strips of 50mm wide pre flamed grey granite using pre
polished grey granite 19mm thick 76%, Pre polished black granite 19mm
thick @ 2% and preflamed 19mm thick grey granite @22% over existing Sqm 1752.00
cement concrete bed in CM 1:4 average 20mm thick pointed with white
cement/colour pigment etc., complete. - using 10mm thick granite slab

14.49 Providing and fixing of wall cladding using 20mm thick gang saw water cut
Shiva gold granite, grey granite in CM 1:3 proportion cut to required shape,
pattern with paper joints, finished with cement mortal using white cement
and colour pigments to match the colour of slab making through jointing Sqm 3542.00
with sealant, making holes 25mmx12mm grooves in joints including curing
etc., complete. (P.No. 108, I.No. 14.49 of PWD SR 2015-16)

14.50 "Providing and fixing skirting of 300mm high using prepolished water
cut/gang saw of 19mm thick grey granite 0.5mm wide chamfered width and
depth and fixing in CM 1:4 of 20mm thick after chipping the walls etc., m 759.00
complete.”
14.51 Providing and laying Hassan Green granite flooring for staircase, treads and
rises using pre polished 20 mm thick water cut green Granite slab laid over
existing cement concrete bed in CM 1:3, average 20mm thick including full
rounding for nosing , cutting 3 line grooves not more than 2 mm wide for Sqm 4456.00
antiskidding, curing etc.,complete.

14.52 Providing and laying plat form using prepolished, water cut / gang saw
40mm thick telephonic Black Granite. laid on existing vertical -supports
and fixing in CM 1:3 proportion. Including cutting to required shape,
pattern with paper joints, including full rounding for nosing, finished with
cement mortar, pointed with colour pigments to match the colour of slab Sqm 3525.00
making through jointing with sealant, making holes 25mm x 12mm grooves
in joints including curing. (P.No. 108, I.No. 14.52 of PWD SR 2015-16)

Page No : 110
14.53 Providing full nosing for 40mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification m 540.00

14.54 Providing half nosing for 40mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification m 360.00

14.55 Providing full nosing for 20mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification. (P.No. 108, I.No. m 270.00
14.55 of PWD SR 2015-16)
14.56 Providing half nosing for 20mm thick granite slab using required machinery
including cost and conveyance of all materials, labour for all items of work,
HOM of equipment etc., complete as per specification m 180.00

14.57 Providing and fixing for flooring 40mm thick sadarhalli grey flammed
granite slab for bath areas in Bathrooms over a bed of 25mm thick CM 1:6 Sqm 1834.00
and fixing granite slab with CM 1:3.
14.58 Providing and fixing granite flooring in combination of 19mm thick (Avg)
gang saw water cut LAKARED granite with 86% and with 14% of 19mm
thicl (avg) Black granite in CM 1:4 proportion with a coat of rough
plastering using CM 1:4, cut to required shape, pattern with paper joints,
finished with cement mortar using white cement and colour pigments to
match the colour of slab making through jointing with sealant, grooves in Sqm 3474.00
joints including cost of curing etc., complete including cost and conveyance
of all materials, labour for all items of work, HOM of equipment etc.,
complete as per specification. (P.No. 109, I.No. 14.58 of PWD SR 2015-16)

14.59 Providing and fixing for flooring 20mm thick gang saw water cut telephonic
black granite in CM 1:4 proportion with a coat of rough plastering using CM
1:4, cut to required shape, pattern with paper joints, finished with cement
mortar using white cement and colour pigments to match the colour of slab
making through jointing with sealant, grooves in joints including cost of Sqm 2392.00
curing etc., complete including cost and conveyance of all materials, labour
for all items of work, HOM of equipment etc., complete as per specification

Page 87 of 375
14.60 Providing and fixing 20mm thick gang saw water cut LAKARED granite in
CM 1:4 proportion with a coat of rough plastering using CM 1:4, cut to
required shape, pattern with paper joints, finished with cement mortar
using white cement and colour pigments to match the colour of slab
making through jointing with sealant, grooves in joints including cost of Sqm 3471.00
curing etc., complete including cost and conveyance of all materials, labour
for all items of work, HOM of equipment etc., complete as per specification .

Page No : 111
14.61.1 Providing and fixing for flooring 20mm thick gang saw water cut
sadarhalli gray granite in CM 1:4 proportion, cut to required shape,
pattern with paper joints, finished with cement mortar using white cement
and colour pigments to match the colour of slab making through jointing sqm 2051.00
with sealant, groves in joints including cost of curing - minimum width of
1200mm

14.61.2 Providing and fixing for flooring 20mm thick gang saw water cut
sadarhalli gray granite in CM 1:4 proportion, cut to required shape,
pattern with paper joints, finished with cement mortar using white cement
and colour pigments to match the colour of slab making through jointing Sqm 1979.00
with sealant, groves in joints including cost of curing - minimum width of
900mm.

14.62 Providing and laying/fixing cement base, precast, pre polished cement
concrete, designer tiles 25mm thick for flooring conforming to IS 1237
heavy duty tiles for flooring, treads of steps and landing, laid on a bed of
12mm thick cement mortar 1:3 mis finished with flush pointing using white
cement, including cost of materials, including cutting, griding the edge to Sqm 1232.00
half/full round wherever required, labour, curing complete as per
specification. (P.No. 109, I.No. 14.62 of PWD SR 2015-16)

14.63 Providing and fixing Ceramic tiles of size 400x400mm for flooring, threads,
steps and landing, laid on a bed of 20mm thick cement mortar 1:3 mix
flush pointing with white cement mixed with matching colour pigment
including curing, cleaning etc., complete. The work includes cost of all Sqm 1132.00
materials, labour charges for all items of work, hire charges for
equipment, , etc., complete as per specification

14.64 Providing and fixing colour glazed tiles of size 300mmx600mm for walls
with borders of size 300x100mm, set in Cement Mortar 1:3 and pointed
with white cement with matching colour pigment with necessary curing,
cleaning including providing and removing scaffolding wherever necessary Sqm 1212.00
etc., complete. The work includes cost of all materials, labour charges for
all items of work, hire charges for equipment, etc., complete as per
specification.

14.65 Providing and fixing colour glazed tiles of size 300mmx450mm for walls
with borders of size 300x100mm, set in Cement Mortar 1:3 and pointed
with white cement with matching colour pigment with necessary curing,
cleaning including providing and removing scaffolding wherever necessary Sqm 1034.00
etc., complete. The work includes cost of all materials, labour charges for
all items of work, hire charges for equipment, etc., complete as per
specification.

Page No : 112
14.67.1 Providing and fixing of wall cladding using 20 mm thick gang saw water cut
granite in CM 1:3 proportion cut to required shape patron with paper joint
finished with cement mortar using white cement and colour pigments to
match the colour of slab making through jointing with sealant, making sqm 2447.00
holes 25mm × 12mm grooves in joints including curing etc., complete -
with grey granite 20mm thick gang saw with minimum width 1200

14.67.2 Providing and fixing of wall cladding using 20 mm thick gang saw water cut
granite in CM 1:3 proportion cut to required shape patron with paper joint
finished with cement mortar using white cement and colour pigments to
match the colour of slab making through jointing with sealant, making sqm 2328.00
holes 25mm × 12mm grooves in joints including curing etc., complete -
with Sadarahalli granite 20mm thick gang saw with minimum width
1200

14.68 Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm
thick on 12mm thick cement mortar 1:3 & jointed with Adhesive / cement
slurry over rough plaster surface excluding cost of rough plasterd surface Sqm 1500.00
and the surface is painted with red apex paint and black apex paint into
the groves.

Page 88 of 375
14.69 Supplying, fabricating and fixing of Stainless steel cladding for walls using
304 grade Stainless steel 16 guage sheet wall cladding of thickness over the
frame made out of 50x50mmx3mm thickness anodized aluminium frame
work at an equal distance of 2 ft vertifically fixed to the wall using 100mm
screws, guttas, anchor bolts and fastners with all necessary bending and Sqm 12350.00
cutting as per the desing and site condition. The frame work finally to be
finished with 12mm BWP plywood to receive the SS sheet on it uniformly

14.70 Providing and laying of teak wooden polished flooring of 12mm thick, high
density timber of approved colour and design with end trims, transition,
profiles, beading, 15mm thick felt, and 20 micron polyester film with 4mm Sqm 4800.00
thick foam underlay etc.,
14.71 Providing and laying of Modular wooden polished flooring of 12mm thick,
high density timber of approved colour and design with end trims,
transition, profiles, beading, 15mm thick felt, and 20 micron polyester film Sqm 2720.00
with 4mm thick foam underlay etc.,
14.72 Providing Venyl flooring of approved quality and make, fixed on the top of
existing flooring fixed with suitable adhesive, including cutting to the Sqm 560.00
requied size and fixing etc. complete
Note:
Lift charges: The above rates are applicable for Ground and basement
floors only. An additional rate of Rs. 2.00/sqm per floor may be added for
every additional floor for items vide Sl.No. 14.1 to 14.72.
Page No. 113

15.0 FINISHING WORK


15.1 KSRB 15.1.1 Providing flush pointing to square rubble, course or
uncoursed stone masonry with cement mortar 1:3, 20mm deep, after raking
joints to depth of 20mm nicely lining, including cost of materials, labour, Sqm 141.00
curing complete as per specifications.
15.2 KSRB 15.1.2 Providing flush pointing to square rubble, course or
uncoursed stone masonry with cement mortar 1:4, 20mm deep, after raking
joints to depth of 20mm nicely lining, including cost of materials, labour, Sqm 140.00
curing complete as per specifications.
15.3 KSRB 15.1.3 – do – Providing ruled pointing to coursed stone masonry with
cement mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely
lining, including cost of materials, labour, curing complete as per Sqm 142.00
specifications.
15.4 KSRB 15.1.4 Providing ruled pointing to coursed stone masonry with
cement mortar 1:4, 20mm deep, after raking joints to depth of 20mm nicely
lining, including cost of materials, labour, curing complete as per Sqm 140.00
specifications.
15.5 KSRB 15.1.5 Providing raised and cut pointing to coursed stone masonry
with cement mortar 1:3, 20mm, after raking joints to depth of 20mm nicely
lining, including cost of materials, labour, curing complete as per Sqm 207.00
specifications.
15.6 KSRB 15.1.6 Providing raised and cut pointing to coursed stone masonry
with cement mortar 1:4, 20mm, after raking joints to depth of 20mm nicely
lining, including cost of materials, labour, curing complete as per Sqm 204.00
specifications.
15.7 KSRB 15.2.1 Providing flush pointing to stone slab pavements, with cement
mortar 1:3, after raking joints, nicely lining, including cost of materials, Sqm 44.00
labour, curing complete as per specifications.
15.8 KSRB 15.2.2 Providing ruled pointing to stone slab pavements with cement
mortar 1:3, 20mm deep, after raking joints , including cost of materials, Sqm 46.00
labour, curing complete as per specifications.
15.9 KSRB 15.3.1 Providing 12mm thick cement plaster in single coat with
cement mortar 1:3, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 211.00
including cost of materials, labour, curing complete as per specifications.

15.10 KSRB15-3.2 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:4, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 204.00
including cost of materials, labour, curing complete as per specifications.

15.11 KSRB15-3.3 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:6, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 193.00
including cost of materials, labour, curing complete as per specifications.

Page 89 of 375
15.12 KSRB15-3.4 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:3, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 234.00
including cost of materials, labour, curing complete as per specifications.

15.13 KSRB15-3.5 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:4, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 221.00
including cost of materials, labour, curing complete as per specifications.
(P.No. 112, I.No. 15.13 of PWD SR 2015-16)
15.14 KSRB15-3.6 : Providing 15mm thick cement plaster in single coat with
cement mortar 1:6, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 208.00
including cost of materials, labour, curing complete as per specifications.

Page No. 115


15.15 KSRB15-3.7 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:3, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 276.00
including cost of materials, labour, curing complete as per specifications.
(P.No. 112, I.No. 15.15 of PWD SR 2015-16)
15.16 KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with
cement mortar 1:4, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 261.00
including cost of materials, labour, curing complete as per specifications.

15.17 KSRB15-3.9 :Providing 18mm thick cement plaster in single coat with
cement mortar 1:6, to brick masonry including rounding off corners
wherever required smooth rendering, : Providing and removing scaffolding, Sqm 245.00
including cost of materials, labour, curing complete as per specifications.

15.18 KSRB15-3.10 : Providing 20mm thick cement plaster in single coat with
cement mortar 1:3, to stone masonry & concrete surface including
rounding off corners wherever required smooth rendering, : Providing and Sqm 289.00
removing scaffolding, including cost of materials, labour, curing complete
as per specifications.
15.19 KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with
cement mortar 1:4, to stone masonry & concrete surface including
rounding off corners wherever required smooth rendering, : Providing and Sqm 271.00
removing scaffolding, including cost of materials, labour, curing complete
as per specifications.
15.20 KSRB15-3.12 :Providing 20mm thick cement plaster in single coat with
cement mortar 1:6, to stone masonry & concrete surface including
rounding off corners wherever required smooth rendering, : Providing and Sqm 254.00
removing scaffolding, including cost of materials, labour, curing complete
as per specifications.
15.21 KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:3, to ceiling including rounding off corners wherever
required smooth rendering, : Providing and removing scaffolding, including Sqm 235.00
cost of materials, labour, curing complete as per specifications. (P.No. 113,
I.No. 15.21 of PWD SR 2015-16)
15.22 KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with
cement mortar 1:4, to ceiling including rounding off corners wherever
required smooth rendering, : Providing and removing scaffolding, including Sqm 225.00
cost of materials, labour, curing complete as per specifications.

15.23 KSRB15-4.1 Extra for providing and mixing waterproofing compound in


cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:3, 12mm thick cost of materials Sqm 7.00
complete as per specifications.
15.24 KSRB15-4.2 Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 12mm thick cost of materials Sqm 5.00
complete as per specifications.
15.25 KSRB15-4.3 Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, for cement mortar 1:4, 15mm thick cost of materials Sqm 7.00
complete as per specifications.
15.26 KSRB15-4.4 Extra for providing and mixing waterproofing compound in
cement plaster work at one kg per bag or in the proportion recommended
by the manufacturers, forcement mortar 1:4, 18mm thick cost of materials Sqm 8.00
complete as per specifications.

Page 90 of 375
15.27 KSRB15-4.5 Extra for providing and mixing waterproofing compound in
cement plaster for stone masonry work at one kg per bag or in the
proportion recommended by the manufacturers, for cement mortar 1:4, Sqm 9.00
20mm thick cost of materials complete as per specifications.
15.28 KSRB15-4.6 Extra for providing and mixing waterproofing compound in
cement plaster for birck masonry work at one kg per bag or in the
proportion recommended by the manufacturers, for cement mortar 1:3, Sqm 12.00
20mm thick cost of materials complete as per specifications.
15.29 KSRB15-4.7 Extra for providing and mixing waterproofing compound in
cement plaster for brick masonry work at one kg per bag or in the
proportion recommended by the manufacturers, for cement mortar 1:4, Sqm 9.00
20mm thick cost of materials complete as per specifications.
Page No. 116
15.30 KSRB15-5.1 : Providing rough cement plastering 15mm thick in single coat
with cement mortar 1:4, to brick masonry for base of dadooing works with
sand of approved quality, providing and removing scaffolding, including Sqm 205.00
cost of materials, labour, curing complete as per specifications. (P.No. 113,
I.No. 15.30 of PWD SR 2015-16)
15.31 KSRB15-5.2 : Providing rough cement plastering 15mm thick in single coat
with cement mortar 1:6, to brick masonry for base of dadooing works with
sand of approved quality, providing and removing scaffolding, including Sqm 192.00
cost of materials, labour, curing complete as per specifications.

15.32 KSRB15-6 : Providing floating coat of cement to plastering and finishing


smooth, including cost of materials, labour, curing complete as per Sqm 19.00
specifications.
15.33 KSRB15-7 : Providing lime rendering for plastering to wall and ceiling,
including cost of materials, labour, curing complete as per specifications. Sqm 32.00

15.34 KSRB 15.8.1 Providing and fixing plaster mesh 100mm wide manufactured
out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc
coating of 120gms per sqm width, along route of walls chipped for services,
junction between RCC and brick walls including cost of materials, labour m 26.00
for fixing complete as per specifications. ( length of mesh only be measured
for payment )

15.35 KSRB 15.8.2 Providing and fixing plaster mesh 150mm wide manufactured
out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc
coating of 120gms per sqm width, along route of walls chipped for services,
junction between RCC and brick walls including cost of materials, labour m 31.00
for fixing complete as per specifications. ( length of mesh only be measured
for payment )

15.36 KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured
out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc
coating of 120gms per sqm width, along route of walls chipped for services,
junction between RCC and brick walls including cost of materials, labour m 36.00
for fixing complete as per specifications. (length of mesh only be measured
for payment) (P. No. 114, I.No. 15.36 of SR 2015-16).

15.37 KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured
out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc
coating of 120gms per sqm width, along exposed corners of walls, m 28.00
coloumns, lintels including cost of materials, labour for fixing complete .
(length of mesh be measured for payment)
15.38 KSRB 15.10.1 Providing white washing to new wall surface in two coats
with lime of approved quality, to give an even shade including cost of Sqm 12.00
materials, labour, complete as per specifications.
15.39 KSRB 15.10.2 Providing white washing for every one additional coat with
lime of approved quality, to give an even shade including cost of materials, Sqm 6.00
labour, complete as per specifications.
15.40 KSRB 15.10.3 Providing white washing to ceiling and / or sloping roof
surface in two coats with lime of approved quality, to give an even shade
including cost of materials, labour, complete as per specifications. Sqm 13.00

15.41 KSRB 15.10.4 Providing white washing to ceiling and / or sloping roof
surface with additional one coat with lime of approved quality, to give an
even shade including cost of materials, labour, complete as per Sqm 7.00
specifications.
Page No. 117

Page 91 of 375
15.42 KSRB 15.11.1Providing cement washing to rough wall surface in one coat
with portland cement slurry to give an even shade after throughly brooming
the surface to remove all dirt, dust, mortar drops and other foreign matter Sqm 11.00
including cost of materials, labour, complete as per specifications.

15.43 KSRB 15.11.2 Providing cement washing on iron surface in one coat with
portland cement slurry mixed with boiled linseed oil to give an even surface
after thoroughly cleaning the surface to remove all dirt, dust, mortar drops Sqm 102.00
and other foreign matter including cost of materials, labour, complete as
per specifications.
15.44 KSRB 15.12.1Providing Gopi colour washing to new wall surface in two
coats with lime and gopi colour of approved quality, to give an even shade
after thoroughly brooming the surface to remove all dirt, dust, mortar drops Sqm 15.00
and other foreign matter including cost of materials, labour, complete as
per specifications.
15.45 KSRB 15.12.2 Providing Gopi colour washing to new wall surface in one
coat with lime and gopi colour of approved quality, to give an even shade
after thoroughly brooming the surface to remove all dirt, dust, mortar drops Sqm 8.00
and other foreign matter including cost of materials, labour, complete as
per specifications.
15.46.1 KSRB15-13 : Applying of distemper KSRB 15-13.1 : Providing and applying
one coat distemper primer of approved brand on wall surface after
throughly brooming the surface to remove all dirt, dust, mortar drops and
other foreign matter including preparing the surface, even and sand paper Sqm 35.00
smooth, cost of materials, labour, complete as per specifications. -wall
surface-

15.46.2 KSRB 15-13.2 : Extra over Item 15-13.1 for applying one coat of distemper
primer over ceiling and / or sloping roof as per specifications. Sqm 3.00

15.47.1 KSRB 15-13.3 : Providing and applying two coats dry distemper of approved
brand, and shade on wall surface including priming coat and whitening
after throughly brooming the surface to remove all dirt, dust, mortar drops
and other foreign matter including preparing the surface even and sand Sqm 73.00
paper smooth, cost of materials, labour, complete as per specifications.

15.47.2 KSRB 15-13.4 : Extra over Item 15-13.3 for applying distemper primer over
Sqm 6.00
ceiling and / or sloping roof as per specifications.
15.48.1 KSRB 15-13.5 : Providing and applying one coat on old surface dry
distemper of approved brand, and shade on wall surface after thoroughly
brooming the surface clean of all gease, dirt, loose pieces of scales including
preparing the surface even and sand paper smooth, cost of material, Sqm 20.00
labour, complete as per specifications. -wall surface-

Page No. 118


15.48.2 KSRB 15-13.6 : Extra over Item 15-13.5 for applying distemper over ceiling
Sqm 2.00
and /or sloping roof as per specifications.
15.48.3 KSRB 15-13.7 : Extra for providing and applying every subsequent cost of
dry distemper of approved brand , for item no. 15-13.3 and 15-13.5 of
approved shade on wall surface cost of materials, labour, complete as per Sqm 14.00
specifications.
15.49.1 KSRB 15-14.1 : Providing and applying two coats with oil bound washable
distemper of approved brand and shade on wall surface including priming
coat with distemper primer after throughly brooming the surface free from
mortar drops and other foreign matter including preparing the surface even Sqm 110.00
and sand paper smooth, cost of materials, labour, complete as per
specifications.

15.49.2 KSRB 15-14.2 : Extra over Item 15-14.1 for applying oil bound washable
distemper on ceiling and / or sloping roof as per specifications. Sqm 8.00

15.50.1 KSRB 15-14.3 : Providing and applying one coat with oil bound washable
distemper of approved brand and shade on wall surface to give an even
shade after throughly brooming the surface free from all grease, dirt, loose
peases of scales, including preparing the surface even and sand paper Sqm 46.00
smooth, cost of materials, labour, complete as per specifications.

15.50.2 KSRB 15-14.4 : Extra over Item 15-14.3 for applying one coat with oil
bound washable distemper on ceiling and / or sloping roof as per Sqm 3.00
specifications.

Page 92 of 375
15.51.1 KSRB 15-15.1 : Providing and applying painting in two coats with plastic
emulsion paint of approved brand on wall surface to give an even approved
shade after thoroughly brushing the surface, free from mortar drops and
other foreign matter including preparing the surface even and sand paper Sqm 87.00
smooth, cost of materials, labour, complete as per specifications.

15.51.2 KSRB 15-15.1 : Providing and applying painting in two coats with plastic
emulsion paint of approved brand on wall surface to give an even approved
shade after thoroughly brushing the surface, free from mortar drops and
other foreign matter including preparing the surface even and sand paper Sqm 90.00
smooth, cost of materials, labour, complete as per specifications. - with
primer. (P. No. 116, I.No. 15.51.2 of SR 2015-16).

15.51.3 KSRB 15-15.2 : Extra over Item 15-15.1 for painting two coats with plastic
emulsion paint of approved brand and shade on ceiling and / or sloping
roof as per specifications. (P. No. 116, I.No. 15.51.3 of SR 2015-16). Sqm 5.00

Page No. 119


15.52.1 KSRB 15-15.3 : Providing and applying painting in one coat with plastic
emulsion paint of approved brand and manufacture on wall surface to give
an even approved shade after throughly brushing the surface, free from
mortar drops and other foreign matter including preparing the surface even Sqm 56.00
and sand paper smooth, cost of materials, labour, complete as per
specifications.

15.52.2 KSRB 15.15.4 : Extra over Item 15-15.3 for painting with one coat plastic
emulsion paint of approved brand and shade on ceiling and / or sloping Sqm 4.00
roof as per specifications.
15.52.3 KSRB 15-15.5 : Extra for providing and applying every subsequent coat of
painting with plastic emulsion paint of approved brand and shade for Item
no.15-15.1 and 15-15.3 cost of materials, labour, complete as per Sqm 37.00
specifications.
15.53.1 KSRB 15-16.1 : Providing and finishing external walls in two coats with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose
powdered material, free from mortar drops and other foreign matter cost of Sqm 89.00
materials, labour, complete as per specifications.

15.53.2 KSRB 15-16.1 : Providing and finishing external walls in two coats with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose
powdered material, free from mortar drops and other foreign matter cost of Sqm 102.00
materials, labour, complete as per specifications. - with primer. (P. No. 117,
I.No. 15.53.2 of SR 2015-16).

15.53.3 KSRB 15-16.3 : Extra for providing and applying every subsequent coat of
waterproofing cement paint of approved brand and shade for Item no.15-
16.1 cost of materials, labour, complete as per specifications. Sqm 34.00

15.54.1 KSRB 15-16.2 : Providing and finishing external walls in one coat with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose Sqm 51.00
powdered material, free from mortar drops and other foreign matter cost of
materials, labour, complete as per specifications.
15.54.2 KSRB 15-16.2 : Providing and finishing external walls in one coat with
waterproof cement paint of approved brand and shade to give an even
shade after throughly brooming the surface to remove all dirt and loose
powdered material, free from mortar drops and other foreign matter cost of Sqm 47.00
materials, labour, complete as per specifications. - with primer

15.54.3 KSRB 15-16.3 : Extra for providing and applying every subsequent coat of
waterproofing cement paint of approved brand and shade for Item no.15-
16.1 and 15-16.2 cost of materials, labour, complete as per specifications. Sqm 34.00

15.55 KSRB 15-17.1 : Applying priming coat over new wood surface and / or
wood based surface with white lead paint priming including preparing the
surface after thoroughly cleaning oil, grease, dirt and foreign matter, sand Sqm 43.00
papering and knotting ready mix paint including cost of materials, labour,
complete as per specifications.
15.56 KSRB 15-17.2 : Applying priming coat over new wood surface and / or
wood based surface after brushing with wood primer pink paint including
preparing the surface after thoroughly cleaning oil, grease, dirt and foreign Sqm 46.00
matter, sand papering and knotting ready mix paint including cost of
materials, labour, complete as per specifications.

Page 93 of 375
Page No. 120
15.57 KSRB 15-17.3 : Applying priming coat over new wood surface and / or
wood based surface after brushing with aluminium paint primer, water
resistant including preparing the surface after thoroughly cleaning oil,
grease, dirt and foreign matter, sand papering and knotting ready mix paint Sqm 42.00
including cost of materials, labour, complete as per specifications.

15.58 KSRB 15-17.4 : Applying priming coat over new wood surface and / or
wood based surface, after brushing with ready mix enamel priming paint
including preparing the surface after thoroughly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting ready mix paint including Sqm 50.00
cost of materials, labour, complete as per specifications.

15.59 KSRB 15-17.5 : Applying priming coat over new wood surface and / or
wood based surface after preparing the surface after throughly cleaning oil,
grease, dirt and foreign matter, sand papering and knotting liquid wood
filler, for varnish including cost of materials, labour, complete as per Sqm 50.00
specifications. (P.No. 118, I.No. 15.59 of SR 2015-16).

15.60.1 KSRB 15-17.6 : Providing and applying painting two coats ( excluding
priming coat ) on new wood surface and / or wood based surface with
enamel paint to give an even shade, cleaning the surface of all dirt, dust
and foreign matter, sand papering including cost of materials, labour, Sqm 97.00
complete as per specifications. (P.No. 118, I.No. 15.60.1 of SR 2016-17).

15.60.2 KSRB 15-17.8 : Extra over Item No. 15-17.6 for applying every subsequent
coat of enamel paint to give an even shade after cleaning the surface of all
dirt, dust and foreign matter, sand papering including cost of materials, Sqm 55.00
labour, complete as per specifications.
15.61.1 KSRB 15-17.7 : Providing and applying painting one coat ( excluding
priming coat ) on new wood surface and / or wood based surface with
enamel paint to give an even shade after cleaning the surface of all dirt, Sqm 62.00
dust and foreign matter, sand papering including cost of materials, labour,
complete as per specifications.
15.61.2 KSRB 15-17.8 : Extra over Item No.15-17.7 for applying every subsequent
coat of enamel paint to give an even shade after cleaning the surface of all
dirt, dust and foreign matter, sand papering including cost of materials, Sqm 55.00
labour, complete as per specifications.
15.62.1 KSRB 15-17.9 : Applying varnish two coats ( excluding priming coat ) on
new wood surface and / or wood based surface undercoating with flatting
varnish and finishing coat with varnish to give an even shade after cleaning
the surface of all dirt, dust and foreign matter, sand papering so as to Sqm 87.00
produce smooth dry, mat surface including cost of materials, labour,
complete as per specifications.

15.62.2 KSRB 15-17.11 : Extra over Item No. 15-17.9 and 15-17.10 for applying
every subsequent coat of varnish to produce a smooth dry and mat surface
after cleaning the surface of all dirt, dust and foreign matter, including cost Sqm 45.00
of materials, labour, complete as per specifications.

Page No. 121


15.63.1 KSRB 15-17.10 : Providing and applying varnishing one coat ( excluding
priming coat ) on previously varnished wood / or wood based surface to give
an even surface after cleaning the surface of all dirt, dust and foreign
matter, sand papering so as to produce a smooth dry and mat surface, Sqm 51.00
including cost of materials, labour, complete as per specifications.

15.63.2 KSRB 15-17.11 : Extra over Item No. 15-17.9 and 15-17.10 for applying
every subsequent coat of varnish to produce a smooth dry and mat surface
after cleaning the surface of all dirt, dust and foreign matter, including cost Sqm 45.00
of materials, labour, complete as per specifications.

15.64 KSRB 15-17.12 : Providing and applying polishing with french polish on
new wood surface and / or wood based surface to give an even surface after
cleaning the surface of all dirt, dust and foreign matter, sand papered Sqm 202.00
smooth, including cost of wood filler and materials, labour, complete as per
specifications.
15.65 KSRB 15-17.13 : Providing and applying polishing with french polish over
previously polished wood or wood based surface to give an even surface
after cleaning the surface of all dirt, dust and foreign matter, sand papered Sqm 107.00
smooth, including cost of wood filler and materials, labour, complete as per
specifications.

Page 94 of 375
15.66 KSRB 15-17.14 : Providing and applying wax polish in two coats on new
wood surface and / or wood based surface, with bees wax polish in
proportion of 2:1.5:1:0.5 ( 2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5
varnish by weight ) to give an even surface after cleaning the surface of all Sqm 93.00
dirt, dust and foreign matter, sand papered smooth, including cost of
materials, labour, complete as per specifications.

15.67 KSRB 15-17.15 : Providing and applying wax polish in single coat on new
wood surface and / or wood based surface, with bees wax polish in
proportion of 2:1.5:1:0.5 ( 2 bees wax : 1.5 linseed oil : 1 turpentine oil : 0.5
varnish by weight ) to give an even surface after cleaning the surface of all Sqm 47.00
dirt, dust and foreign matter, sand papered smooth, including cost of
materials, labour, complete as per specifications.

15.68 KSRB 15-17.16 : Providing and applying painting two coats ( excluding
priming coat ) on new wood surface and / or wood based surface with coal
tar paint to give an even shade after cleaning the surface of all dirt, dust Sqm 60.00
and foreign matter, including cost of materials, labour, complete as per
specifications.
15.69 KSRB 15-17.17 : Providing and applying painting one coat ( excluding
priming coat ) on new wood surface and / or wood based surface with coal
tar paint to give an even shade after cleaning the surface of dirt, dust and Sqm 40.00
foreign matter, including cost of materials, labour, complete as per
specifications.
Page No. 122
15.70 KSRB 15-17.18 : Providing and applying painting one coat ( excluding
priming coat) on previously painted wood surface and / or wood based
surface with coal tar paint to give an even shade after cleaning the surface Sqm 33.00
of all dirt, dust and foreign matter, including cost of materials, labour,
complete as per specifications.
15.71 KSRB 15-17.19: Providing and applying painting one coat ( excluding
priming coat ) on previously painted wood surface and / or wood based
surface with black japan paint to give an even shade after cleaning the Sqm 56.00
surface of all dirt, dust and foreign matter, including cost of materials,
labour, complete as per specifications.
15.72 KSRB 15-17.20: Applying additional one coat ( excluding priming coat) on
previously painted wood surface and / or wood based surface with black
japan paint to give an even shade after cleaning the surface of all dirt, dust Sqm 50.00
and foreign matter, including cost of materials, labour, complete as per
specifications.
15.73 KSRB 15-18.1 : Applying red lead ready mix priming coat over new steel or
other metal surface including preparing the surface after throughly cleaning
oil, grease, dirt and other foreign matter, and scoured with wire brushes, Sqm 41.00
fine steel wool, sand papers including cost of materials, labour, complete as
per specifications.
15.74 KSRB 15-18.2 : Providing and applying enamel metal paint two coats
( excluding priming coat ) over new steel or other metal surface brushing to
give an even shade after cleaning oil, grease, dirt and other foreign matter, Sqm 95.00
including cost of materials, labour, complete as per specifications. (Page No.
120 Item No. 15.74 of SR 2015-16).
15.75 KSRB 15-18.3 : Providing and applying enamel metal paint one coat
(excluding priming coat ) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 61.00
foreign matter, including cost of materials, labour, complete as per
specifications.
15.76 KSRB 15-18.4 : Providing and applying alluminium paint two coats
(excluding priming coat ) over new steel or other metal surface brushing to
give an even shade after cleaning oil, grease, dirt and other foreign matter, Sqm 74.00
including cost of materials, labour, complete as per specifications.

15.77 KSRB 15-18.5 : Providing and applying alluminium paint one coat
(excluding priming coat ) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 48.00
foreign matter, including cost of materials, labour, complete as per
specifications.
15.78 KSRB 15-18.6 : Providing and applying black japan paint one coat
(excluding priming coat ) on previously painted steel or other metal surface
brushing to give an even shade after cleaning oil, grease, dirt and other Sqm 46.00
foreign matter, including cost of materials, labour, complete as per
specifications.
Page No. 123

Page 95 of 375
15.79 KSRB 15-18.7 : Extra for applying every subsequent black japan paint on
previously painted steel or other metal surface brushing to give an even
shade after cleaning of oil, grease, dirt and other foreign matter, including Sqm 40.00
cost of materials, labour, complete as per specifications.
15.80 KSRB 15-19.1 : Providing and applying ready mix priming coat over
concrete / masonry / asbestos cement sheet / plastered surfaces including
preparing the surface after thoroughly cleaning of oil, grease, dirt and other Sqm 37.00
foreign matter, and sand papering including cost of materials, labour,
complete as per specifications.
15.81 KSRB 15-19.2 : Providing and applying spray painting in two coats
(excluding priming coat ) over concrete / masonry / asbestos cement
sheet / plastered surfaces with flat wall paint of approved brand to give
even shade after cleaning the surface of all dirt, dust and other foreign Sqm 85.00
matter, and sand papering including cost of materials, labour, complete as
per specifications.

15.82 KSRB 15-19.3 : Providing and applying spray painting in one coat(excluding
priming coat ) over concrete / masonry / asbestos cement sheet / plastered
surfaces with flat wall paint of approved brand to give even shade after
cleaning the surface of all dirt, dust and other foreign matter, and sand Sqm 55.00
papering including cost of materials, labour, complete as per specifications.

15.83 KSRB 15-20.1 : Providing and applying floor painting with ready mix paint
in two coats ( exluding priming coat ) on new concrete / asbestos cement
sheet / plastered surfaces brushing to give an even shade after preparing
the surface after throughly cleaning oil, dirt, dust other foreign matter and Sqm 71.00
sand papering including cost of materials, labour, complete as per
specifications.

15.84 KSRB 15-20.2 : Providing and applying floor painting with ready mix paint
in one coat ( exluding priming coat ) on new concrete / asbestos cement
sheet / plastered surfaces brushing to give an even shade after preparing
the surface after throughly cleaning oil, dirt, dust other foreign matter and Sqm 46.00
sand papering including cost of materials, labour, complete as per
specifications.

15.85 KSRB 15-21.1 : Providing and applying wax polish on new concrete floor
and vertical plastered surface using approved brand to give an even shade
after preparing the surface after thoroughly cleaning oil, dirt, dust other Sqm 44.00
foreign matter, including cost of materials, labour, complete as per
specifications.
15.86 KSRB 15-21.2 : Providing and applying wax polish on new concrete floor
and vertical plastered surface using approved brand to give an even shade
after preparing the surface after thoroughly cleaning oil, dirt, dust other Sqm 43.00
foreign matter, including cost of materials, labour, complete as per
specifications. previously polished concrete floor
15.87 KSRB 15-22.1 : Providing marble chips skirting or dado ( upto 30cms
height ) rubbed and polished to granolithic finish, top layer 6mm thick with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size dark shade pigment with ordinary cement
( in top layer only ) laid in cement marble powder 3:1 ( 3 cement : 1 marble
powder by weight ) in proportion of 4:7 (4 cement marble powder mix : 7 Sqm 1345.00
marble chips by volume ) overall thickness 24mm (18mm thick under layer,
6mm thick top layer ) in cement mortar of mix 1:3 including cost of
materials, labour, complete as per specifications.

15.88 KSRB 15-22.2 : Providing marble chips skirting or dado ( upto 30cms
height ) rubbed and polished to granolithic finish, top layer 6mm thick,
with white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, light shade pigment with white cement ( in
top layer only ) laid in cement marble powder 3:1 ( 3 cement : 1 marble
powder by weight ) in proportion of 4:7 ( 4 cement marble powder mix : 7 Sqm 1395.00
marble chips by volume ) overall thickness 24mm (18mm thick under layer,
6mm thick top layer ) in cement mortar of mix 1:3 including cost of
materials, labour, complete as per specifications.

Page No. 124

Page 96 of 375
15.89 KSRB 15-22.3 : Providing marble chips skirting or dado ( upto 30cms
height ) rubbed and polished to granolithic finish top layer 6mm thick with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, medium shade pigment with approximately
50% white cement and 50% ordinary cement (in top layer only ) laid in
cement marble powder 3:1 ( 3 cement :1 marble powder by weight ) in Sqm 1378.00
proportion of 4:7 ( 4 cement marble powder mix : 7marble chips by volume)
overall thickness 24mm ( 18mm thick under layer, 6mm thick top layer ) in
cement mortar of mix 1:3 including cost of materials, labour, complete as
per specifications.

15.90 KSRB 15-22.4 : Providing marble chips skirting or dado ( upto 30cms
height ) rubbed and polished to granolithic finish top layer 6mm thick with
white, black, chocolate, grey, yellow or baroda green marble chips from
smallest to 4mm nominal size, white cement without any pigment ( in top
layer only ) laid in cement marble powder 3:1 ( 3 cement : 1 marble powder
by weight ) in proportion of 4:7 ( 4 cement marble powder mix : 7 marble Sqm 1340.00
chips by volume ) overall thickness 24mm (18mm thick under layer, 6mm
thick top layer ) in cement mortar of mix 1:3 including cost of materials,
labour, complete as per specifications.

15.91 KSRB 15-22.5 : Extra labour for work in dado exceeding 30 cms in height
Sqm 30.00
including cost of labour, complete as per specifications.
15.92 KSRB 15-23.1 : Providing pre-cast grey colour mosaic tiles 20mm thick
with marble chips of white, black, chocolate, grey, yellow or baroda green
from smallest to 6mm nominal size, with ordinary cement ( in top layer only
) for skirting and rises of steps ( not exceeding 30cms height) on 10cms m 332.00
thick cement mortar 1:3 jointed with neat cement slurry, rubbed and
polished to granolithic finish, including cost of materials, labour, complete
as per specifications.

15.93 KSRB 15-23.2 : Providing pre-cast mosaic tiles using light shade pigment
with white cement 20mm thick with marble chips of white, black,
chocolate, grey, yellow or baroda green from smallest to 6mm nominal size,
with ordinary cement ( in top layer only ) for skirting and rises of steps ( not
exceeding 30cms height ) on 10cms thick cement mortar 1:3 jointed with m 388.00
neat cement slurry, rubbed and polished to granolithic finish, including
cost of materials, labour, complete as per specifications.

15.94 KSRB 15-23.3 : Providing pre-cast mosaic tiles using medium shade
pigment using approximately 50% white cement and 50% ordinary cement
20mm thick with marble chips of white, black, chocolate, grey, yellow or
baroda green from smallest to 6mm nominal size, with ordinary cement ( in
top layer only ) for skirting and rises of steps ( not exceeding 30cms height ) m 345.00
on 10cms thick cement mortar 1:3 jointed with neat cement slurry, rubbed
and polished to granolithic finish, including cost of materials, labour,
complete as per specifications.

Page No. 125


15.95 KSRB 15-23.4 : Providing pre-cast mosaic tiles of white shade with white
cement without any pigment 20mm thick with marble chips of white, black,
chocolate, grey, yellow or baroda green from smallest to 6mm nominal size,
with ordinary cement ( in top layer only ) for skirting and rises of steps ( not
exceeding 30cms height ) on 10cms thick cement mortar 1:3 jointed with m 303.00
neat cement slurry, rubbed and polished to granolithic finish, including
cost of materials, labour, complete as per specifications.

15.96 Providing melamine polishing of approved shade including removing and


refixing of doors shutters scraping with blade and rubbing with zero size
sand paper and applying sealer coat by way of spraying with necessary
compressor and applying patty after rubbing with steel wool including two Sqm 856.00
coats of approved shade of melamine polish etc., complete.

15.97 Providing melamine polishing of approved shade including removing and


refixing of doors shutters, glass, beading and existing polishing, scraping
with blade and rubbing with zero size sand paper and applying sealer coat
by way of spraying with necessary compressor and applying patty after Sqm 1038.00
rubbing with steel wool including two coats of approved shade of melamine
polish etc., complete.

15.98.1 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement I.e 0.25% by weight of cement. - Sqm 6.00
for CM 1:4, 20mm thick

Page 97 of 375
15.98.2 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement I.e 0.25% by weight of cement. - Sqm 5.00
for CM 1:4, 12mm thick
15.98.3 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement I.e 0.25% by weight of cement. - Sqm 4.50
for CM 1:6, 20mm thick
15.98.4 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament
polyster fibers 6mm in cut length for use as micro reinforcement for
application at 125 grams per bag of cement I.e 0.25% by weight of cement. - Sqm 5.50
for CM 1:6, 12mm thick
15.99 Providing and mixing Synthetic fiber 100% virgin triangular monofilament
polyester fibers for use as micro secondary reinforcement in guitie and
shotcrete civil works with application dosage of 125-175 grams per bag of Sqm 12.00
cement i.e. 0.25%-0.30% by weight of cement.

Page No. 126


15.100.1 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and 200
gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 25.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confirming to ASTM C 1116 ACI 524-93. - for CM 1:3 , 20mm
thick

15.100.2 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and 200
gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 16.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confirming to ASTM C 1116 ACI 524-93. - for CM 1:3 , 12mm
thick

15.100.3 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and 200
gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 22.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confirming to ASTM C 1116 ACI 524-93. - for CM 1:4 , 20mm
thick

15.100.4 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and 200
gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 14.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confirming to ASTM C 1116 ACI 524-93. - for CM 1:4 , 12mm
thick

15.100.5 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and 200
gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 19.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confirming to ASTM C 1116 ACI 524-93. - for CM 1:6 , 20mm
thick

15.100.6 Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin
polypropylene fibers contains no olefin materials and are specially
engineered manufactured to use as cementitious micro reinforcement.
Application @125 gms for 1:3 cement mortar, 150 gms for 1:4 CM and 200
gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 14.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm
long fibers shall be used in the top coat. Fibermesh Harbourite fibers
should be confirming to ASTM C 1116 ACI 524-93. - for CM 1:6, 12mm
thick

Page 98 of 375
15.101.1 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process.It should prevent the growth of micro organisms like bacteria, mold
fungus, mildew etc. on concrete surfaces. Application top of plaster to be Sqm 40.00
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM
1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro
blocker shall confirm to ASTM C-1116 type 111 4.1.3. - for CM 1:3, 20mm
thick

15.101.2 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process.It should prevent the growth of micro organisms like bacteria, mold
fungus, mildew etc. on concrete surfaces. Application top of plaster to be Sqm 27.00
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM
1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro
blocker shall confirm to ASTM C-1116 type 111 4.1.3. - for CM 1:3, 12mm
thick

15.101.3 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process.It should prevent the growth of micro organisms like bacteria, mold
fungus, mildew etc. on concrete surfaces. Application top of plaster to be Sqm 35.00
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM
1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro
blocker shall confirm to ASTM C-1116 type 111 4.1.3. - for CM 1:4, 20mm
thick

15.101.4 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process.It should prevent the growth of micro organisms like bacteria, mold
fungus, mildew etc. on concrete surfaces. Application top of plaster to be Sqm 23.00
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM
1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro
blocker shall confirm to ASTM C-1116 type 111 4.1.3. - for CM 1:4, 12mm
thick

15.101.5 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process.It should prevent the growth of micro organisms like bacteria, mold
fungus, mildew etc. on concrete surfaces. Application top of plaster to be Sqm 33.00
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM
1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro
blocker shall confirm to ASTM C-1116 type 111 4.1.3. - for CM 1:6, 20mm
thick

15.101.6 Providing and mixing fibermesh stealth micro blocker anti microbial multi
filament 100% virgin polypropylene fibers which should be free from
reprocessed olefin materials, containing an active anti microbial ingredient
built in to the polymer structure of the fiber itself during manufacturing
process.It should prevent the growth of micro organisms like bacteria, mold
fungus, mildew etc. on concrete surfaces. Application top of plaster to be Sqm 30.00
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM
1:3, 175 gm for CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro
blocker shall confirm to ASTM C-1116 type 111 4.1.3. - for CM 1:6, 12mm
thick

15.102. Providing and mixing Harbourite 12 mm fine fibrillated 100% virgin


polypropylene fibers which should be free from reprocessed olefin materials
and specifically manufactured for use as cementitious micro reinforcement
application rate of 175 gms to 250 gms per bag of cement or 1.8 kg per cum Sqm 68.00
in the guinite/shotcret and designed to an optimum gradation for use as
concrete secondary reinforcement.

15.103. Providing external walls with texture finish using approved brand paint,
applied uniformly in three coats over one coat of primer including cost of all
materials, machineries, labour, transportation, loading and unloading, all
lead and lift and all other incidental charges including scaffolding and Sqm 340.00
removing stains, complete as per specifications.

Page 99 of 375
15.104. Providing and finishing external walls in two coats over one coat of primer
with antifungal paint of approved brand and shade to give an even shade
after thoroughly brooming the surface to remove all dirt and loose powdered
material, free from mortar drops and other foreign matter cost of materials, Sqm 180.00
labour, complete as per specifications. (P.No. 124, I.No. 15.104 of CSR
2015-16).
Page No. 127
15.105. Providing textured paint of approved quality, colour and shade to wall
surface after cleaning and rubbing the wall surface with wire brush of
medium size emery stone to remove all the loosely adhering particles, the
surface is then cleaned with water and ensured that it is in line and level.
The textured material is then mixed with 40-50% of clean water until a
homogeneous thick slurry is formed, the slurry is left for 5-10 min, to react
completely with ingredients. The textured finish prepared as above is then
applied to the wall surface with suitable roller/spray gun/putty/ blade/ Sqm 439.00
trowel to get the desired finish. The finished surface shall be applied with
two coats of exterior apex paint of approved shade. The rate includes
providing and removing scaffolding, all lead and lift and all other incidental
charges etc., complete as per directions of the Engineer-in-charge of the
work.

15.106. Providing applying two coats of wall putty to inside plastered walls and
ceiling using white cement putty. Scrapping and levelling the surface using
steel blade and preparing the surface even and smooth by using different
grade sand papers, including cost of all materials, cost of labour and Sqm 78.00
scaffolding etc., complete as per the specification. (P.No. 125, I.No. 15.106
of SR 2015-16).

Note :
1 Lift charges : The Above rates are applicable for Ground floor only An
additional rate of Rs. 6.00/Sqm per floor for inside plastering works only
may be added for every additional floor. Below or above the ground floor.

2 Lift charges : The Above rates are applicable for Ground floor. An
additional rate of Rs. 4.00 / Sqm per floor for painting works of exterior
walls only may be added for every additional floor.
3 Scafolding charges : An additional rate of Rs. 12.00 /sqm per floor for
external plastering works only may be added for every additional floor.

4 Scafolding charges : An Additional rates of Rs. 4.00/sqm for painting works


of exeterior walls only maybe added for every additional floor.

Page No. 128

16.0 16.REPAIRS TO BUILDINGS


16.1.1 KSRB 24-1 : Removing white wash or colour wash by steel brushing and /
or scraping, sand papering and preparing wall surface smooth including
repairs to scraches, cost of labour, complete as per specifications. Sqm 9.00
Specification No.KBS. (P.No. 128/ I.No. 16.1.1 of CSR 2016-17)

16.1.2 KSRB 24-2 : Extra for removing white wash or colour wash by steel
brushing and / or scraping, sand papering the ceiling and / or sloping roof
surface smooth including repairs to scraches, cost of labour, complete as Sqm 10.00
per specifications.
16.1.3 KSRB 24-3 : Extra for washing the wall surface spoiled by smoke, soot, with
clear water before sand papering the surface smooth including necessary
repairs to scraches, cost of labour, complete as per specifications. Sqm 4.00

16.1.4 KSRB 24-4 : Extra for Item No. 24-3 washing the ceiling and / or sloping
roof surface spoiled by smoke soot with clear water before sand papering
the surface smooth and including necessary repairs to scraches, cost of Sqm 4.00
labour, complete as per specifications.
16.2.1 KSRB 24-5 : Cleaning and washing of decorated wall surface with soap,
soda and water including cost of materials, labour, complete as per Sqm 4.00
specifications. Specification No.KBS
16.2.2 KSRB 24-6 : Extra for KSRB 24-5 cleaning and washing the old ceiling
and / or sloping roof with soap, soda and water including cost of materials, Sqm 4.00
labour, complete as per specifications.
16.3.1 KSRB 24-7 : Cleaning and washing the old plastered wall surface with soap,
soda, water including cost of materials, labour, complete as per Sqm 4.00
specifications.
16.3.2 KSRB 24-8 : Extra for Item No. 24-7 cleaning and washing the old plastered
ceiling and / or sloping roof surface with soap, soda, water including cost of Sqm 4.00
materials, labour, complete as per specifications.

Page 100 of 375


16.4 KSRB 24-9 : Cleaning and washing of stone masonry wall surface with
nitric acid including cost of materials, labour, complete as per Sqm 5.00
specifications. Specification No.KBS
16.5 KSRB 24-10 : Removing the old paint or polish from wood and / or wood
based surface with paint remover of approved brand / manufacturer and
making surface even including cost of materials, labour, complete as per Sqm 65.00
specifications. Specification No.KBS. (P. No. 127, I.No. 16.5 of CSR 2015-
16).
Page No. 130
16.6 KSRB 24-11 : Removing the old paint or polish from wood and / or wood
based surface with caustic soda solution and making surface even
including cost of materials, labour, complete as per specifications. Sqm 45.00
Specification No.KBS
16.7 KSRB 24-12 : Removing the old paint from wood and / or wood based
surface with blow lamp and making surface even including cost of
materials, labour, complete as per specifications. Specification No.KBS Sqm 93.00

16.8 KSRB 24-13 : Removing the old paint from steel and / or other metal
surface with hand scraping and making surface even including cost of
labour, complete as per specifications. Specification No.KBS. (P. No. 128, Sqm 84.00
I.No. 16.8 of CSR 2015-16).
16.9 KSRB 24-14 : Removing the old paint from steel and / or other metal
surface with flame cleaning and making surface even including cost of Sqm 93.00
material, labour, complete as per specifications. Specification No.KBS
16.10 KSRB 24-15 : Removing the old paint from steel and / or other metal
surface with paint remover of approved brand / manufacturer cleaning and
making surface even including cost of material, labour, complete as per Sqm 64.00
specifications. Specification No.KBS
16.11 KSRB 24-16 : Fixing small pieces ( not exceeding 0.015 cum ) for making
good wherever hinges etc., have been removed from frames or joinery etc.,
with teak wood excluding cost of materials but including cost of labour, Piece 26.00
complete as per specifications. Specification No.KBS
16.12 KSRB 24-17 : Providing and fixing small pieces ( not exceeding 0.015 cum )
for making good wherever hinges etc., have been removed from frames or
joinery etc., with honne wood including cost of materials, labour, complete Piece 172.00
as per specifications. Specification No.KBS
16.13 KSRB 24-18 :Providing and fixing small pieces ( not exceeding 0.015 cum )
for making good wherever hinges etc., have been removed from frames or
joinery etc., with matti / nandi wood including cost of materials, labour, Piece 146.00
complete as per specifications. Specification No.KBS. (P.No. 128, I.No.
16.13 of SR 2015-16)
16.14 KSRB 24-19 : Providing and fixing small pieces ( not exceeding 0.015 cum )
for making good wherever hinges etc., have been removed from frames or
joinery etc., with Sal wood pieces ( not exceeding 0.015 cum ) including Piece 122.00
cost of materials, labour, complete as per specifications. Specification
No.KBS
16.15 KSRB 24-20 : Renewing bars, styles and rails, straight for joinery upto
50mm thick including mitres, haunching, mortices etc., and removing the
old defective pieces and replacing with Teak wood including cost of Piece 1126.00
materials, labour, complete as per specifications. Specification No.KBS

16.16 KSRB 24-21 :Renewing bars, styles and rails, straight for joinery upto
50mm thick including mitres, haunching, mortices etc., and removing the
old defective pieces and replacing with Honne wood including cost of Piece 499.00
materials, labour, complete as per specifications. Specification No.KBS

16.17 KSRB 24-22 : Renewing bars, styles and rails, straight for joinery upto
50mm thick including mitres, haunching, mortices etc., and removing the
old defective pieces and replacing with Matti / Nandi woodincluding cost of Piece 428.00
materials, labour, complete as per specifications. Specification No.KBS

Page No. 131


16.18 KSRB 24-23 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding one sqm per leaf, removing or
dismantling excluding cost of wood but including cost of labour, complete Leaf 577.00
as per specifications. Specification No.KBS. (P.No. 129, I.No. 16.18 of SR
2015-16)

Page 101 of 375


16.19 KSRB 24-24 :Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding one sqm per leaf, removing or
dismantling excluding cost of wood but including cost of labour, complete Leaf 766.00
as per specifications. Specification No.KBS exceeding one sqm but not
exceeding two sqm per leaf

16.20 KSRB 24-25 : Rewedging, cramping joinery of any description with new
wedges in glue or white lead and repinning including rehanging or refixing
of shutters, hinges or pivots, not exceeding one sqm per leaf, removing or
dismantling excluding cost of wood but including cost of labour, complete Leaf 1082.00
as per specifications. Specification No.KBS exceeding two sqm

16.21 KSRB 24-26 : Making repairs to joinery at angles with 300mm x 25mm x
3mm length of MS flat forged to shape and let into wood work, counter
sunk, drilled and screwed including cost of materials, labour, complete as Each 112.00
per specifications. Specification No.KBS
16.22 KSRB 24-27 : Renewing Honne wood battens in roof including making good
the holes in walls, removal of rubbish to the dumping round with a lead
upto 50 m including cost of materials, labour, complete as per cum 13446.00
specifications. Specification No.KBS
16.23 KSRB 24-28 :Renewing Matti / Nandi wood battens in roof including
making good the holes in walls, removal of rubbish to the dumping round
with a lead upto 50 m including cost of materials, labour, complete as per cum 11800.00
specifications. Specification No.KBS
16.24 KSRB 24-29 :Renewing Sal wood battens in roof including making good the
holes in walls, removal of rubbish to the dumping round with a lead upto
50 m including cost of materials, labour, complete as per specifications. cum 10417.00
Specification No.KBS
16.25 KSRB 24-30 : Removal of old broken glass panes (any thickness of size,
quality or description) from wooden frames, glazed with putty or fixed with
beads including cost of labour, complete as per specifications. Specification Sqm 124.00
No.KBS
16.26 KSRB 24-31 : Removal of old broken glass panes (any thickness of size,
quality or description) from metal frames, glazed with putty or fixed with
beads including cost of labour, complete as per specifications. Specification Sqm 175.00
No.KBS
16.27 KSRB 24-32 : Removing serviceable glass of any description from old wood
or metal frames (any thickness or size, quality or description) hacking out
old putty etc., including risk and making good breakages in taking out and
handling, stacking within a lead of 50 m. including cost of labour, complete Sqm 179.00
as per specifications. Specification No.KBS. (P.No. 129, I.No. 16.27 of SR
2015-16)

16.28 KSRB 24-33 : Supplying and fixing new teak wood beads wherever
necessary including cost of materials, labour, complete as per m 40.00
specifications. Specification No.KBS
16.29 KSRB 24-34 : Supplying and fixing new Honne wood beads wherever
necessary including cost of materials, labour, complete as per m 33.00
specifications. Specification No.KBS
16.30 KSRB 24-35 : Renewal of old putty of glass panes including cost of
materials, labour, complete as per specifications. Specification No.KBS m 36.00
24.2.6
Page No. 132
16.31 KSRB 24-36 : Removing the glazed tiles in patches in area exceeding 10
tiles and not exceeding 5 sqm including removing old tiles preparing
surfaces and laying or setting new or old tiles complete including cost of Sqm 804.00
materials, ( excluding cost of tiles ) labour, complete as per specifications.
Specification No.KBS
16.32 KSRB 24-37 : Removing the mosaic tiles in patches in area exceeding 10
tiles and not exceeding 5 sqm including removing old tiles preparing
surfaces and laying or setting new or old tiles complete including cost of Sqm 619.00
materials, ( excluding cost of tiles ) labour, complete as per specifications.
Specification No.KBS
16.33 KSRB 24-38 : Cutting out cracks of roof terrace to V - section cleaning out,
wetting, grouting with cement and sand slurry 1:3 (1 cement, 3 sand)
including cost of materials, labour, complete as per specifications. m 64.00
Specification No.KBS
16.34 KSRB 24-39 : Cutting out cracks of roof terrace to V - section cleaning out
and filling solidly with a hot mixure of bitumen and clean dry sand 1:1 by
weight including cost of materials, labour, complete as per specifications. Sqm 66.00
Specification No.KBS

Page 102 of 375


16.35.1 KSRB 24-40 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:3 including curing cost of
materials, labour, complete as per specifications. Specification No.KBS Sqm 170.00
24.2.1
16.35.2 KSRB 24-43 : Add from Item no. 24-40 for every 5mm thick increase after
10mm with respective mortars including curing cost of materials, labour, Sqm 49.00
complete as per specifications.
16.36.1 KSRB 24-41 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:4 including curing cost of
materials, labour, complete as per specifications. Specification No.KBS Sqm 154.00
24.2.1
16.36.2 KSRB 24-43 : Add from Item no. 24-40, 24-41, 24-42 for every 5mm thick
increase after 10mm with respective mortars including curing cost of Sqm 45.00
materials, labour, complete as per specifications.
16.37.1 KSRB 24-42 : Dubbing out on old irregular walls average 10mm thick and
making good the surface with cement mortar 1:6 including curing cost of
materials, labour, complete as per specifications. Specification No.KBS Sqm 138.00
24.2.1
16.37.2 KSRB 24-43 : Add from Item no. 24-40, 24-41, 24-42 for every 5mm thick
increase after 10mm with respective mortars including curing cost of Sqm 41.00
materials, labour, complete as per specifications.
16.38 KSRB 24-44 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:3 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 292.00
labour, complete as per specifications. Specification No.KBS 24.2.1 (P.No.
131, I.No. 16.38 of SR 2016-17).

16.39 KSRB 24-45 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:4 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 275.00
labour, complete as per specifications. Specification No.KBS 24.2.1 (P.No.
131, I.No. 16.39 of SR 2016-17).

16.40 KSRB 24-46 : Repairs to plaster in patches of 2.5 sqm and less in walls,
ceilings 10 to 20mm thick in cement mortar 1:6 including cutting the
patches in proper shape and replastering the surface of the wall including
disposal of rubbish with a lead of 50m including curing cost of materials, Sqm 259.00
labour, complete as per specifications. Specification No.KBS 24.2.1

Page No. 133


16.41 Removing of existing old or broken wash basin / urinals and disposing it
with all cost and conveyance labour for all items of work, HOM of
equipment with all lead and lift, loading and unloading, transportation
charges and all other incidental charges etc., complete as per specification Each 321.00
and directions of the Engineer-in-charge of the work.

16.42 Removing of existing old or broken Water closet Indian / Eurpoean and
disposing it with all cost and conveyance labour for all items of work, HOM
of equipment with all lead and lift, loading and unloading, transportation
charges and all other incidental charges etc., complete as per specification Each 296.00
and directions of the Engineer-in-charge of the work.

16.43 Removing of existing old Sanitary and plumbing pipelines, stacking and
disposing it with all cost and conveyance labour for all items of work, HOM
of equipment with all lead and lift, loading and unloading, transportation
charges and all other incidental charges etc., complete as per specification m 99.00
and directions of the Engineer-in-charge of the work.

16.44 External sweeping and terrace cleaning - Cleaning of outer periphery like
roads footpaths curb stones terrace including removing grass dust etc., to
the nearest garbage pit using suitable coconut broomstic,bombay
broomstick, squezers /wipers / rubberbrushes, coir brushes, bamboo Sqm 1.00
baskets, plastic bukets mugs trolley etc., complete

16.45 Cleaning stone parapets removing of dirt dust etc., using suitrable soap
powder, coconut broomstick, squeezers / wipers/ rubber brushes, coir
brushes, plastric brushjes, mugs, booster pumps with portable Sqm 1.00
arrangement, hose pipe etc., complete including cost of water charges and
electrical charges.

Page 103 of 375


16.46 Cleaning Quadrangle chajjas including removing of dirt dust etc., using
suitrable soap powder , coconut broomstick, squeezers / wipers/ rubber
brushes, coir brushes, plastric brushjes, mugs, booster pumps with
portable arrangement, hose pipe etc., complete excluding water charges Sqm 11.00
including electrical charges and all safety measures.

16.47 Cleaning sub surface drains including removing of dirt dust etc., using
suitrable soap powder , coconut broomstick, squeezers / wipers/ rubber
brushes, coir brushes, plastric brushjes, mugs, booster pumps with m 13.00
portable arrangement, hose pipe etc., complete
16.48 Cleaning surface drains including removing of dirt dust etc., using suitrable
soap powder , coconut broomstick, squeezers / wipers/ rubber brushes,
coir brushes, plastric brushjes, mugs, booster pumps with portable m 8.00
arrangement, hose pipe etc., complete.
16.49 Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage
units, furnitures,electrical & electronic equipments, doors, windows,
curtains, blinds etc., including cleaning of dust, etc., using suitable bombay
broom stick, squezers / wipers/rubber brushes, mop sticks, coir brushes, Sqm 2.00
bamboo baskets, plastic buckets, trolleys, wiping cloths, carry bags,
etc.,removing the debris to the nearest garbage pit complete.

Page No. 134

17.0 ROADS AND BRIDGES - CARRIAGE OF MATERIALS


17.1 KSRRB M100-1 Loading and Unloading of Stone Boulder / Stone
aggregates /Sand/ Kanker / Moorum. KSRRB M100-1 : Placing tipper at
loading point, loading with front end loader,dumping, turning for return cum 57.00
trip, excluding time for haulage and return trip complete as per
specifications. MORTH -100/ Chapter 1
17.2 KSRRB M100-2. Loading and Unloading of Stone Boulders by Manual
cum 111.00
Means complete as per specifications. MORTH -100/ Chapter 1
17.3 KSRRB M100-3 Loading and Unloading of Cement or Steel by Manual
Tonne 152.00
Means and as per specifications complete MORTH -100/ Chapter 1
17.4 KSRRB M100-4.1. Cost of Haulage Excluding Loading and Unloading
t.km 2.00
MORTH -100/ Chapter 1 Case-I : Surface Road
17.5 KSRRB M100-4.2. Haulage of materials by tipper excluding cost of loading,
unloading and stacking complete as per specifications. MORTH -100/ t.km 2.00
Chapter 1 Case-II : Unsurfaced Gravelled Road
17.6 KSRRB M100-4.3. Haulage of materials by tipper excluding cost of loading,
unloading and stacking complete as per specifications.MORTH Chapter 1
Case-III : Katcha Track and Track in River Bed/Nallah Bed and Choe Bed t.km 4.00

17.7 KSRRB M100-5. Supply of quarried stone, hand breaking into coarse
aggregate 63mm nominal size (passing 80 mm and retained on 50 mm
sieve) and stacking as directed complete as per specifications. MORTH - cum 661.00
100/ Chapter 1
17.8 KSRRB M100-6. Crushing of stone boulders of 150 mm size in an
integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyor and vibrating cum 798.00
screens to obtain stone aggregates of 13.2 mm nominal size complete.
MORTH -100/ Chapter 1
17.9 KSRRB M100-7. Crushing of stone boulders of 150 mm size in an
integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyor and vibrating cum 803.00
screens to obtain stone aggregates of 20 mm nominal size complete.
MORTH -100/ Chapter 1
17.10 KSRRB M100-8. Crushing of stone boulders of 150 mm size in an
integrated stone crushing unit of 200 tonnes per hour capacity comprising
of primary and secondary crushing units, belt conveyor and vibrating cum 717.00
screens to obtain stone aggregates of 40mm nominal size complete. MORTH
-100/ Chapter 1
Page No. 136

18.0 18.SITE CLEARANCE AND DISMANTLING


18.1 KSRRB 200-1. Cutting of trees girth from 300mm to 600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials earth filling in the depressions / pit, labour charges complete as Each 299.00
per specifications. MORTH specification clause 201/ Chapter 2

Page 104 of 375


18.2 KSRRB 200-2. Cutting of trees girth from 600mm to 900mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials earth filling in the depressions / pit, labour charges complete as Each 922.00
per specifications. MORTH specification clause 201/ Chapter 2

18.3 KSRRB 200-3. Cutting of trees girth from 900mm to 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials earth filling in the depressions / pit, labour charges complete as Each 2243.00
per specifications. MORTH specification clause 201/ Chapter 2

18.4 KSRRB 200-4. Cutting of trees girth from 1800mm to 2700mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials earth filling in the depressions / pit, labour charges complete as Each 3489.00
per specifications. MORTH specification clause 201/ Chapter 2

18.5 KSRRB 200-5. Cutting of trees girth from 2700mmto 3600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials earth filling in the depressions / pit, labour charges complete as Each 6977.00
per specifications. MORTH specification clause 201/ Chapter 2

18.6 KSRRB M200-6.1 Cutting of trees girth from 300mm to 600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials with all lifts earth filling in the depressions / pit, complete as per Each 543.00
specifications. MORTH Specification No. 201
18.7 KSRRB M200-6.2 Cutting of trees girth from 600mm to 900mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials with all lifts earth filling in the depressions / pit, complete as per Each 1031.00
specifications. MORTH Specification No. 201
18.8 KSRRB M200-6.3 Cutting of trees girth from 900mm to 1800mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials with all lifts earth filling in the depressions / pit, complete as per Each 2360.00
specifications. MORTH Specification No. 201
18.9 KSRRB M200-6.4 Cutting of trees girth from 1800mm to 2700mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials with all lifts earth filling in the depressions / pit, complete as per Each 7149.00
specifications. MORTH Specification No. 201
18.9.1 KSRRB M200-6.4 Cutting of trees girth from 2700mm to 3600mm including
cutting of trunks, branches and removal of stumps stacking of serviceable
materials with all lifts earth filling in the depressions / pit, complete as per Each 25755.00
specifications. MORTH Specification No. 201
18.10 KSRRB M200-7.1. Clearing grass and removal of rubbish by manual means
and stacking outside the periphery of the area cleaned complete as per Ha 25755.00
specifications. MORTH Specification No. 201
18.11 KSRRB 200-8. Clearing and grubbing road land including uprooting rank
vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm,
by manual means, in area of light jungle, removal of stumps, disposal of Sqm 10.00
unserviceable materials, stacking of serviceable materials labour charges
complete as per specifications. MORTH / Chapter 2
18.12 KSRRB 200-9. Clearing and grubbing road land including uprooting rank
vegetation, grass, brush, shrubs, saplings and trees of girth upto 300mm,
by manual means, in area of thorney jungle, removal of stumps, disposal of
unserviceable materials, stacking of serviceable materials labour charges Sqm 15.00
complete as per specifications. MORTH / Chapter 2

18.13 KSRRB M200-10.1. Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300
mm, removaL of stumps of trees cut earlier and disposal of unserviceable
materials and stacking of serviceable material to be used or auctioned,
including removal and disposal of top organic soil not exceeding 150 mm in Ha 77458.00
thickness complete as per specifications. I. By Manual Means: A. In area of
light jungle. MORTH Specification No. 201

18.14 KSRRB M200-10.2. Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300
mm, removaL of stumps of trees cut earlier and disposal of unserviceable
materials and stacking of serviceable material to be used or auctioned, Ha 103406.00
including removal and disposal of top organic soil not exceeding 150 mm in
thickness complete as per specifications. I. By Manual Means:B. In area of
thorny jungle.

Page No. 138

Page 105 of 375


18.15 KSRRB M200-11.1. Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300
mm, removalof stumps of trees cut earlier and disposal of unserviceable
materials and stacking of serviceable material to be used or auctioned,
including removal and disposal of top organic soil not exceeding 150 mm in Ha 18526.00
thickness complete as per specifications . II. By Mechanical Means:A. In
area of light jungle. MORTH Specification No. 201

18.16 KSRRB M200-11.2. Clearing and grubbing road land including uprooting
rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300
mm, removalof stumps of trees cut earlier and disposal of unserviceable
materials and stacking of serviceable material to be used or auctioned, Ha 22907.00
including removal and disposal of top organic soil not exceeding 150 mm in
thickness complete as per specifications .II. By Mechanical Means:B. In
area of thorny jungle

18.17 KSRRB M200-12.1. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 454.00
specifications. i) Lime /Cement Concrete. I. By Manual Means :A. Lime
Concrete, cement concrete grade M-10 and below. MORTH Specification No.
202. (P.No. 136/ I. No. 18.17 of CSR 2015-16)

18.18 KSRRB M200-12.2. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 557.00
specifications. i) Lime /Cement Concrete. I. By Manual Means :B. Cement
Concrete Grade M-15 & M-20. MORTH Specification No. 202. (P.No. 136,
I.No. 18.18 of CSR 2015-16)

18.19 KSRRB M200-12.3. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 1589.00
specifications. C. Prestressed / Reinforced cement concrete grade M-20 &
above. MORTH Specification No. 202

18.20 KSRRB M200-13.1. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 390.00
specifications. II. By Mechanical Means. A. Cement Concrete Grade M-15
&M-20. MORTH Specification No. 202

18.21 KSRRB M200-13.2. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable cum 739.00
material and stacking the serviceable material with all lifts complete as per
specifications. II.By Mechanical Means. MORTH Specification No. 202

18.22 KSRRB M200-14.1. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable cum 248.00
material and stacking the serviceable material with all lifts complete as per
specifications. ii) Dismantling Brick / Tile work. A. In lime mortar. MORTH
Specification No. 202

18.23 KSRRB M200-14.2. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable cum 351.00
material and stacking the serviceable material with all lifts complete as per
specifications. ii) Dismantling brick/Tile work B. In cement mortar. MORTH
Specification No. 202

Page 106 of 375


18.24 KSRRB M200-14.3. Dismantling of existing structures like culverts,
bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable cum 207.00
material and stacking the serviceable material with all lifts complete as per
specifications. ii) Dismantling brick/Tile work C. In mud mortar.MORTH
Specification No. 202

18.25 KSRRB M200-14.4. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 186.00
specifications. ii) Dismantling brick/Tile work D. Dry brick pitching or
brick soling. MORTH Specification No. 202

18.26 KSRRB M200-15.1. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 289.00
specifications. iii) Dismantling Stone Masonry. A. Rubble Stone masonry in
lime mortar. MORTH Specification No. 202

Page No. 139


18.27 KSRRB M200-15.2. Dismantling of existing structures like culverts,
bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 351.00
specifications. iii) Dismantling Stone Masonry.B. Rubble stone masonry in
cement mortar. MORTH Specification No. 202

18.28 KSRRB M200-15.3. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 248.00
specifications. iii) Dismantling Stone Masonry C. Rubble stone masonry in
mud mortar. MORTH Specification No. 202

18.29 KSRRB M200-15.4. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable cum 227.00
material and stacking the serviceable material with all lifts complete as per
specifications. iii) Dismantling Stone Masonry D. Dry rubble masonry.
MORTH Specification No. 202

18.30 KSRRB M200-15.5. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 207.00
specifications. iii) Dismantling Stone MasonryE. Dismantling stone pitching
/ dry stone spalls. MORTH Specification No. 202

18.31 KSRRB M200-15.6.Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 248.00
specifications. Dismantling brick/Tile work F. Dismantling Boulders laid in
wire crates including opening of crates and stacking dismantled materials.

18.32 KSRRB M200-16.Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 665.00
specifications. iv) Dismantling wood work wrought framed and fixed in
frames of trusses upto a Height of 5m above Plinth Level.

Page 107 of 375


18.33 “KSRRB M200-17.1. Dismantling of existing structures like culverts,
bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per Tonne 1893.00
specifications. v) Steel work in all types of Sections upto a Height of 5 m
above plinth level excluding Cutting of Rivet. – A. Including dismembering.”
(P.No.137/ I.No. 18.33 of CSR 2015-16)

18.34 KSRRB M200-17.2. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per Tonne 1426.00
specifications. v)Steel work in all types of Sections upto a Height of 5 m
above plinth level excluding Cutting of Rivet– B. Excluding dismembering.

18.35 Dismantling of existing structures like culverts, bridges, retaining walls and
other structure comprising of masonry, cement concrete, wood work, steel
work, including T&P and scaffolding wherever necessary, sorting the
dismantled material, disposal of unserviceable material and stacking the RIVET 14.00
serviceable material with all lifts complete as per specifications. B for
cutting rivets.

18.36 KSRRB M200-18.1. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per Nos 2.00
specifications. vi) Scraping of Bricks Dismantled from Brick work including
Stacking - A. In Lime / Cement mortar.

18.37 KSRRB M200-18.2. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable Nos 1.00
material and stacking the serviceable material with all lifts complete as per
specifications. B. In mud mortar.

18.38 KSRRB M200-19.1. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per cum 723.00
specifications. vii) Scraping of stones from dismantled stone masonry – A.
In cement and lime mortar.

18.39 KSRRB M200-19.2.Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable cum 153.00
material and stacking the serviceable material with all lifts complete as per
specifications. B. In mud mortar.

18.40 KSRRB M200-20.Dismantling of existing structures like culverts, bridges,


retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable Sqm 21.00
material and stacking the serviceable material with all lifts complete as per
specifications. viii) Scraping plaster in lime or cement mortar from brick /
stone masonry.

18.41 KSRRB M200-21.1. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per m 267.00
specifications. ix) Removal of all types of Hume pipes and stacking
including earthwork and dismantling of masonry works – A. Upto 600 mm
dia

Page 108 of 375


18.42 KSRRB M200-21.2. Dismantling of existing structures like culverts,
bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per m 362.00
specifications. Removal of all types of Hume pipes and stacking including
earthwork and dismantling of masonry works – B. Above 600 mm to 900
mm dia.

18.43 KSRRB M200-21.3. Dismantling of existing structures like culverts,


bridges, retaining walls and other structure comprising of masonry, cement
concrete, wood work, steel work, including T&P and scaffolding wherever
necessary, sorting the dismantled material, disposal of unserviceable
material and stacking the serviceable material with all lifts complete as per m 619.00
specifications. Removal of all types of Hume pipes and stacking including
earthwork and dismantling of masonry works C. Above 900 mm dia.

18.47 KSRRB M200-24. Dismantling of cement concrete pavement by mechanical


means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in
volume and stock piling at designated locations and disposal of dismantled
materials stacking serviceable and unserviceable materials seperately cum 899.00
complete as per specifications. MORTH Specification No. 202

18.48 KSRRB M200-25. Dismantling of guard rails by manual means and


disposal of dismantled materials with all lifts and stacking serviceable
materials and unserviceable materials seperately complete as per m 87.00
specifications. MORTH Specification No. 202
Page No. 138
18.49 KSRRB M200-26. Dismantling Kerb stone by manual means and disposal
of dismantled materials with all lifts and complete as per specifications. m 12.00
MORTH Specification No. 202
18.50 KSRRB M200-27. Dismantling of Kerb stone channel by manual means
including and disposal of dismantled material with all lifts and complete as m 18.00
per specifications. MORTH Specification No. 202
18.51 KSRRB M200-28.1. Dismantling of kilometre stone including cutting of
earth, foundation and disposal of dismantled material with all lifts and
back filling of pit complete as per specifications. A. 5th KM stone ( quantity Each 469.00
of cement concrete = 0.392 cum). MORTH Specification No. 202

18.52 KSRRB M200-28.2.Dismantling of kilometre stone including cutting of


earth, foundation and disposal of dismantled material with all lifts and
back filling of pit complete as per specifications B. Ordinary KM stone Each 277.00
( quantity of cement concrete = 0.269 cum ).
18.53 KSRRB M200-28.3. Dismantling of kilometre stone including cutting of
earth, foundation and disposal of dismantled material with all lifts and
back filling of pit complete as per specifications C. Hectometer stone Each 55.00
( quantity of cement concrete = 0.048 cum ].
18.54 KSRRB M200-29. Dismantling of barbed wire fencing / wire mesh fencing
including posts, foundation concrete, back filling of pit by manual means
including disposal of dismantled material with all lifts and stacking
serviceable material and unserviceable material separately complete as per m 66.00
specifications. MORTH Specification No. 202

18.55 KSRRB M200-30. Dismantling of CI water pipe line 600 mm dia including
disposal with all lifts and stacking of serviceable material and unserviceable
material separately under supervision of concerned department complete as m 137.00
per specifications. MORTH Specification No. 202

18.56 KSRRB M200-31. Removal of cement concrete pipe of sewer gutter 1500
mm dia under the supervision of concerned department including disposal
with all lifts and stacking of serviceable and unserviceable material
separately but excluding earth excavation and dismantling of masonry m 168.00
works complete as per specifications. MORTH Specification No. 202

18.57 KSRRB M200-32. Removal of Telephone / Electric poles including


excavation and dismantling of foundation concrete and lines under the
supervision of concerned department, disposal with all lifts and stacking
the serviceable and unserviceable material separatelycomplete as per Nos 217.00
specifications. MORTH Specification No. 202

Page No. 141

19.0 EARTH WORK, EROSION CONTROL AND DRAINAGE

Page 109 of 375


19.1 KSRRB 300 - Excavation for road, drains and similar works KSRRB 300-1.
Earthwork excavation by manual means in ordinary soil involving an
average horizontal throw upto 2 meters and an average lift upto 0.5 m,
excavated surface leveled and sides neatly dressed, the disposed earth to be cum 130.00
leveled neatly after breaking of clods complete as per specifications. MORTH
/ Chapter 3

19.2 KSRRB 300-2. Earthwork excavation by manual means in hard soil


involving an average horizontal throw upto 2 meters and an average lift
upto 0.5 m, excavated surface leveled and sides neatly dressed, the cum 179.00
disposed earth to be leveled neatly after breaking of clods complete as per
specifications. MORTH / Chapter 3
19.3 KSRRB 300 - Excavation for road formation KSRRB 300-3. Earthwork
excavation and forming in embankment by manual means in ordinary soil
(When earth is taken from bank cutting or from borrow pits ) including
breaking of clods, spreading to required line and level, forming, and cost of cum 164.00
all labour complete as per specifications. ( excluding watering and
compaction of earth ) (with all lead and lift) MORTH / Chapter 3

19.4 KSRRB 300-4. Earthwork excavation and forming in embankment by


manual means in hard soil (When earth is taken from bank cutting or from
borrow pits ) including breaking of clods, spreading to required line and
level, forming, and cost of all labour complete as per specifications. cum 445.00
( excluding watering and compaction of earth ) (with all lead and lift)
MORTH / Chapter 3

19.5 KSRRB 300-5. Excavation in soft rock with blasting for formation of roads
including stacking neatly, to uniform line and level including cost of
explosives, labour, HOM of machineries and equipments complete as per cum 445.00
specifications. (with all lead and lift) MORTH / Chapter 3

19.6 KSRRB 300-6. Excavation soft rock without blasting for formation of roads
including stacking neatly, to uniform line and level including cost of
explosives, labour, HOM of machineries and equipments complete as per cum 1201.00
specifications. (with all lead and lift) MORTH / Chapter 3

19.7 KSRRB 300-7. Excavation in hard rock by blasting for formation of roads
including stacking to uniform line and level as directed by the engineer
including cost of explosives, labour, HOM of machineries and equipments cum 578.00
complete as per specifications. (with all lead and lift) MORTH / Chapter 3

19.8 KSRRB 300-8. Excavation in hard rock by chiselling and / or wedging


where blasting is prohibited for formation of roads including stacking to
uniform line and level including cost of all labour complete as per cum 1813.00
specifications. (with all lead and lift) MORTH / Chapter 3
19.13 Excavation in Hard Rock (requiring blasting) with disposal KSRRB M300-
13. Excavation for roadway in hard rock (requiring blasting) by drilling,
blasting and breaking, trimming of bottom and side slopes in accordance
with requirements of lines, grades and cross sections, loading and disposal cum 161.00
of cut road and complete as per specifications (Excavated rock credited to
contractor). MORTH Specification No. 301

19.14 Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with


Disposal KSRRB M300-14. Excavation for roadwork in soil with hydraulic
excavator of 0.9 cum bucket capacity including cutting and loading in
tippers, trimming bottom and side slopes, in accordance with requirements cum 41.00
of lines, grades and cross sections, and transporting to the embankment
location and complete as per specifications. MORTH Specification No.301

Page No : 143
19.15 Excavation in Ordinary Rock using Hydraulic Excavator CK-90 and Tippers
with Disposal KSRRB M300-15. Excavation for roadway in ordinary rock
with hydraulic excavator of 0.9 cum bucket capacity including cutting and
loading in tippers, transporting to embankment site and trimming bottom cum 56.00
and side slopes in accordance with requirements of lines, grades and cross
sections complete as per specifications. MORTH Specification No. 301

19.16 Excavation in Hard Rock (blasting prohibited) KSRRB M300-16.1.


Excavation for roadway in hard rock (blasting prohibited) with rock
breakers including breaking rock, loading in tippers and disposal and
trimming bottom and side slopes in accordance with requirements of lines, cum 373.00
grades and cross sections complete as per specifications. A. Mechanised
MORTH Specification No. 301

Page 110 of 375


19.17 Excavation in Hard Rock (blasting prohibited) KSRRB M300-16.2.
Excavation for roadway in hard rock (blasting prohibited) with rock
breakers including breaking rock, loading in tippers and disposal and
trimming bottom and side slopes in accordance with requirements of lines, cum 1183.00
grades and cross sections complete as per specifications. B. Manual
Method. MORTH Specification No. 301

19.18 KSRRB M300-17. Excavation for road way in hard rock ( controlled
blasting) with rock brakers including breaking rock, loading in tippers
transporting to embankment site and trimming bottom and side slopes in cum 182.00
accordance with requirement of lines, grades and cross sections complete
as per specifications. MORTH Specification No. 301
19.19 Excavation in Marshy Soil KSRRB M300-18. Excavation for roadway in
marshy soil with hydraulic excavator 0.9 cum bucket capacity including
cutting and loading in tippers and disposal and trimming of bottom and
side slopes in accordance with requirements of lines, grades and cross cum 47.00
sections complete as per specifications. MORTH Specification No. 301

19.20 Removal of Unserviceable Soil with Disposal KSRRB M300-19. Removal of


unserviceable soil including excavation, loading and disposal but excluding
replacement by suitable soil which shall be paid separately as per clause cum 33.00
300.5 complete as per specifications. MORTH Specification No. 301

19.30 KSRRB 300- Extra additional lead KSRRB 300-26.1. Extra for every 7.5m
additional lead of 7.50 mtr. additional lead beyond 15m but upto 60m by
manual means for all kinds of soils except hard rock including cost of all cum 6.00
labour complete as per specifications. MORTH Chapter 3

19.31 KSRRB 300- Extra additional lead KSRRB 300-26.2. When lead is more
than 60m upto 500m by any means of conveyance including loading and
unloading for all kinds of soils except hard rock including cost of all labour cum 6.00
complete as per specifications. MORTH Chapter 3
19.33 KSRRB 300-28. Box cutting / trenching the sub grade to proper slope,
camber and removing inequalities including removing the stuff and
depositing on the road side slopes ( cutting of earthwork shall be paid
seperately in the respective item on the basis of classification of the Sqm 2.00
excavation) including cost of all labour complete as per specifications.
MORTH Chapter 3

Page No : 144
19.36 KSRRB M300- Turfing with Sods/Seeding and Mulching KSRRB M300-31.
Turfing with Sods-Furnishing and laying of the live sods of perenial turf
forming grass on embankment slope, verges or other locations shown on
the drawing or as directed by the Engineer including preparation of ground, Sqm 110.00
fetching of sods and watering. complete as per specifications. MORTH
Specification No. 307

19.42 KSRRB M300- Sub-Surface Drains with Perforated Pipe. KSRRB M300-36.
Construction sub-surface drain with perforated pipe of 100 mm internal
diameter of metal / asbestos cement / cement concrete / PVC, closely
jointed, perforations ranging from 3mm to 6mm depending upon size of
crushed stone material surrounding the pipe, with 150mm bedding below m 587.00
the pipe and 300mm cusion above the pipe, cross-section of excavation
450x550mm. Excavated material to be utilised in roadway at site complete
as per specifications. MORTH Specification No. 309

19.43 KSRRB M300- Sub-Surface Drains KSRRB M300-37. Construction of


aggregate sub-surface drain 300mm x 450mm with crushed stone
aggregates conforming to Table 300-4, excavated material to be utilised in m 245.00
roadway complete as per specifications. MORTH Specification No. 309

19.44 KSRRB M300-Underground Drain at Edge of Pavement KSRRB M300-38.


Construction of coverd drain 1m x 1m (inside dimension) with RCC M20
grade 10cm thick for walls and floor, laid over 10cm thick 1:3:6 PCC bed
and covered with M30 grade RCC slab of 15cm thick excluding earth work m 5708.00
including reinforcement @ 35 kg/rmt and form work complete as per
specifications. MORTH 309

19.45 KSRRB M300- Preparation and Surface Treatment of Formation. KSRRB


M300-39. Preparation and Surface Treatment of Formation by removing
mud and slurry, watering to the extent needed to maintain the desired
moisture content, trimming to the required line, grade, profile and rolling Sqm 2.00
with 8-10 tonne smooth sheeled roller, complete as per Clause 310.
complete as per specifications. MORTH Specification No. 310

Page 111 of 375


19.46 KSRRB M300 Earth work on Hill Road KSRRB M300-40. Excavation in hilly
Areas in Soil by Mechanical means. Excavation soil in hilly areas by
mechanical means including cutting and trimming of side slopes and cum 77.00
disposing of excavated earth and complete as per specifications. MORTH
Specification No. 301
19.47 KSRRB M300-41. Excavation in Hilly Areas in Ordinary Rock by
Mechanical means not requiring Blasting. Excavation in hilly area in
ordinary rock not requiring blasting by mechanical means including cutting cum 121.00
and trimming of slopes and disposal of cut material and complete as per
specifications. MORTH Specification No. 301
19.48 KSRRB M300-42. Excavation in Hilly Areas in Hard Rock Requiring
Blasting. Excavation hilly areas in hard rock requiring blasting by
mechanical means including trimming of slopes and disposal of cut cum 331.00
material and complete as per specification. MORTH Specification No. 301

Page No. 145


19.51 KSRRB 300-45. Scarifying stone metal crust 50mm to 100mm thick with
pick axes along with premix carpet / surface dressing and stacking of old
serviceable materials by manual means including cost of all labour charges Sqm 80.00
complete as per specifications. MORTH / Chapter 3

19.52 KSRRB 300-46. Scarifying stone metal crust 50mm to 100mm thick by
road roller with scarifier along with 20mm premix carpet / surface dressing
and stacking of old serviceable materials including cost of all labour Sqm 39.00
charges, HOM of machinaries complete as per specifications. MORTH /
Chapter 3
19.53 KSRRB 300-47. Scarifying kankar / gravel / metal crust upto 150mm thick
with pick axes and disposal of stuff including cost of all labour charges Sqm 40.00
complete as per specifications. MORTH / Chapter 3
19.54 KSRRB 300-48. Scarifying kankar / gravel / metal crust upto 150mm thick
with power roller and scarifier, disposal of stuff including cost of all labour
charges, HOM of machineries complete as per specifications. MORTH / Sqm 24.00
Chapter 3
19.55 KSRRB 300-49. Scarifying bituminous course 50mm to 75mm thick along
with premix carpet / surface dressing by manual means without disturbing
the base and stacking of the debris materials including cost of all labour Sqm 90.00
charges complete as per specifications. MORTH / Chapter 3

19.56 KSRRB 300-50. Scarifying bituminous course 50mm to 75mm thick along
with premix carpet / surface dressing by road roller attached with scarifier
without disturbing the base and stacking the debris including cost of all Sqm 39.00
labour charges, HOM of machineries complete as per specifications.
MORTH / Chapter 3
19.57 KSRRB 300-51. Making 50mm x 50mm furrows at 450 to the centre line of
the road and at one metre interval in the existing thin bituminous wearing
course including sweeping, taking out old materials, stacking the debris Sqm 5.00
cost of all labour charges complete as per specifications. MORTH / Chapter
3
19.58 KSRRB M300- Scarifying Existing Granular Surface to a Depth of 50mm by
Manual Means. KSRRB M300-52.1. Scarifying the existing granular road
surface to a depth of 50mm and disposal of scarified material and complete Sqm 30.00
as per specifications. MORTH Specification No. 305.4.3

19.59 KSRRB M300-52.2. Scarifying Existing Bituminous surface to a depth of


50mm by Mechanical Means. Scarifying the existing bituminous road
surface to a depth of 50mm and disposal of scarified material and complete Sqm 3.50
as per specifications. MORTH Specification No. 305.4.3
Page No. 146
19.60 KSRRB M300- Construction of Embankment with Material Gravel/
Murrum. KSRRB M300-53. Construction of embankment with approved
material Gravel/Murrum with all lifts and leads, transporting to site,
spreading, grading to required slope and compacting to meet requirement
Table 300- 2 complete as per specifications.(Including cost of gravel / cum 325.00
murrum, watering charges & compaction by vibratory roller to 95% of
proctors density) MORTH Specification No. 305

Page 112 of 375


19.61 KSRRB M300-Construction of Embankment with Material deposited from
Roadway cutting. KSRRB M300-54. Construction of embankment with
approved material deposited at site from roadway cutting and excavation
from drain and foundation of other structures graded and compacted to cum 95.00
meet requirement of Table 300-2 complete asper specifications.which
includes , watering charges & compaction by vibratory roller) MORTH
Specification No. 305

19.62 KSRRB M300-Construction of Subgrade and Earthen Shoulders. KSRRB


M300-55. Construction of sub-grade and earthen shoulders with approved
material Gravel/Murrum with all lifts & leads, transporting to site,
spreading, grading to required slope and compacted to meet requirement of
Table No. 300-2 complete as per specifications (including cost of earth, cum 349.00
watering charges & compaction by vibratory rollercompaction by vibratory
roller to 97% of proctors density) MORTH Specification No. 305

19.63 KSRRB M300-Construction of Rockfill Embankment. KSRRB M300-56.


Construction of rockfill embankment with availabel broken hard rock
fragments of size not exceeding 300mm laid in layers not exceeding 500mm
thick including filling of surface voids with stone spalls, blinding top layer cum 36.00
with granular material, rolled with vibratory road roller, all complete as per
Clause 313 complete as per specifications. MORTH Specification No. 313

19.64 KSRRB 300-Compaction KSRRB 300-58. Compaction of original ground


with maximum of 6 passes of 8 to 10 tonnes power roller including filling in
depression occuring during rolling including cost of all labour, HOM of Sqm 6.00
machinery complete as per specifications. MORTH / Chapter 3

19.66 KSRRB M300-59.2. Loosening, levelling and compacting origial ground


supporting embankment to facilitate placement of first layer of
embankment, scarified to a depth of 150mm, mixed with water at OMC and
then compacted by rolling so as to achieve minimum dry density as given in
Table 300-2 for embankment construction. complete as per specifications. cum 23.00
Case-II: Compacting original ground supporting embankment.(which
includes watering charges & compaction by vibratory roller) MORTH
Specification No. 305.3.4

19.67 KSRRB 300-60. Extra for laying earth by manual means as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done simultaneously with excavation of earth work and cum 16.00
dressing but excluding rolling and watering including cost of all labour
complete as per specifications. MORTH / Chapter 3
19.68 KSRRB 300-61. Extra for laying earth by manual means as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done from stacked materials including breaking of clods cum 105.00
and dressing but excluding rolling and watering including cost of all labour
complete as per specifications. MORTH / Chapter 3
Page No. 147
19.69 KSRRB 300-62. Extra for laying earth by mechanical means as per
specifications for compaction in 250mm thick loose layers when laying of
earth in layers is done from stacked materials including breaking of clods
and dressing but excluding rolling and watering including cost of all labour, cum 58.00
HOM of machineries complete as per specifications. MORTH / Chapter 3

19.70 KSRRB M300-63. Construction of Embankment with Flyash / Pond Ash


available from Coal or Lignite Burning Thermal Plants as Waste Material.
Construction of embankment with flyash conforming to Table 1 of
IRC:SP:58-2001 obtained from coal or lignite burning thermal power cum 72.00
stations as waste material, spread and compacted in layer of 200mm
thickness each at OMC, all as specified in IRC:SP:58-2001 and as per
approved plans complete as per specifications.

19.71 KSRRB 300-64.1. Extra for watering the earth to bring the earth upto
required optimum moisture content manually including cost of all labour cum 12.00
complete as per specifications. MORTH / Chapter 3
19.72 KSRRB 300-64.2. Extra for watering the earth to bring the earth upto
required optimum moisture content with mechinery including cost of all
labour, HOM of machineries complete as per specifications. MORTH / cum 2.00
Chapter 3
19.73 KSRRB 300-65. Extra for rolling to specification with the use of vibratory
roller when earth is at suitable moisture content with desired field density
not less than 95% of maximum dry density ( modified heavy proctor test ) cum 13.00
including HOM of machineries complete as per specifications. MORTH /
Chapter 3

Page 113 of 375


19.77 KSRRB M300-Horticulture KSRRB M300-Spreading of sludge farm yard
manure or/ and good earth KSRRB M300-1. Spreading of sludge farm yard
manure or/ and good earth in required thickness (cost of sludge, farm yard cum 103.00
manure or/and good earth to be paid for separately) complete as per
specifications. MORTH Specification No. 307
19.78 KSRRB M300- Grassing with Doobs grass KSRRB M300- 2.1. Grassing with
Doobs grass including watering and maintenance of the lawn for 30 days or
more till the grass forms a thick lawn free from weeds and fit for moving
including supplying good earth if needed complete as per specifications. Sqm 46.00
MORTH Specification No. 307 i) In rows 15 cm apart in either direction.

19.79 KSRRB M300-2.2. Grassing with Doobs grass KSRRB M300- 2.1. Grassing
with Doobs grass including watering and maintenance of the lawn for 30
days or more till the grass forms a thick lawn free from weeds and fit for
moving including supplying good earth if needed complete as per Sqm 85.00
specifications. MORTH Specification No. 307 ii) In rows 7.5 cm apart in
either direction

19.80 KSRRB M300-Making lawns including ploughing and dradding with


‘swagha’ breaking of clod KSRRB M300-3. Making lawns including
ploughing and breaking of clod, removal of rubbish, dressing and supplying
doobs grass roots and planting at 15 cm apart, including supplying and Sqm 16.00
spreading of farm yard manure at rate of 0.18 cum per 100 sqm complete
as per specifiifications. MORTH Specification No. 307

Page No. 148


19.81 KSRRB M300- Maintenance of lawns or Turfing KSRRB M300-
4.Maintenance of lawns or Turfing of slopes (rough grassing) for a period of
one year including watering etc complete as per specifications. MORTH Sqm 103.00
Specification No. 307
19.82 KSRRB M300-Turfing lawns with fine grassing including ploughing,
dressing KSRRB M300-5. Turfing lawns with fine grassing including
ploughing, dressing including breaking of clods, removal of rubbish,
dressing and supplying doobs grass roots at 10 cm apart, including Sqm 23.00
supplying and spreading of farm yard manure at rate of 0.6 cum per 100
sqm complete as per specifications. MORTH Specification No. 307

19.83 KSRRB M300- Maintenance of lawns with fine grassing for the first year
KSRRB M300-6. Maintenance of lawns with fine grassing for the first year
including watering etc complete as per specifications. MORTH Specification Sqm 92.00
No. 307
19.84 KSRRB M300- Planting and maintenance permanent hedges KSRRB M300-
7.1. Planting permanent hedges including digging of trenches, 60 cm wide
and 45 cm deep, refilling the excavated earth mixed with farmyard manure,
supplied at the rate of 4.65 cum per 100 metres and supplying and m 296.00
planting hedge plants at 30 cm apart complete as per specifications. A)
Planting permanent hedges including digging of trenches MORTH
Specification No. 307

19.85 “KSRRB M300-7.2. Planting and maintenance permanent hedges KSRRB


M300-7.1. Planting permanent hedges including digging of trenches, 60 cm
wide and 45 cm deep, refilling the excavated earth mixed with farmyard
manure, supplied at the rate of 4.65 cum per 100 metres and supplying m 208.00
and planting hedge plants at 30 cm apart complete as per specifications.
B) Maintenance of hedge for one year

19.86 KSRRB M300- Planting and Maintaining of Flowering Plants and Shrubs
KSRRB M300- 8.1. Planting and Maintaining of Flowering Plants and
Shrubs - A) Planting flowring plants and shrubs in central verge MORTH m 46.00
Specification No. 307
19.87 KSRRB M300- 8.2. Planting and Maintaining of Flowering Plants and
Shrubs KSRRB M300- 8.1. Planting and Maintaining of Flowering Plants
and Shrubs B) Maintenance of flowering plants and shrubs in central verge Km 218743.00
for one year.
19.88 KSRRB M300- Planting of trees and their maintenance for one year KSRRB
M300-9. Planting of trees by the road side (Avenue trees) in 0.60 m dia
holes, 1 m deep dug in the ground, mixing the soil with decayed farm
yard/sludge manure, planting the saplings, backfilling the trench, watering, Each 1050.00
fixing the tree guard and maintaining the plants for one year complete as
per specifications. MORTH Specification No. 307

Page 114 of 375


19.89 KSRRB M300-Renovation lawns including, weeding, forking the ground, top
dressing with forked soil KSRRB M300-10. Renovation lawns including,
weeding, forking the ground, top dressing with forked soil, watering and
maintenance the lawns, for 30 days or more, till the grass forms a thick
lawn, free from weeds, and fit for moving and disposal of rubbish as Sqm 17.00
directed, including supplying good earth, if needed but excluding the cost of
well decayed farmyard namure complete as per specifications. MORTH
Specification No. 308

Page No. 149


19.90 KSRRB M300-Supply at site of work well decayed farm yard manure
KSRRB M300-11. Supply at site of work well decayed farm yard manure,
from any available source, approved by the engineer in charge including cum 204.00
screening and stackin complete as per specifications. MORTH Specification
No. 308.2
19.91 KSRRB 300-Supply at site of work/ store-deoiled neem cake KSRRB 300-
12. Supply at site of work/ store-deoiled neem cake duly packed in used
gunny bags complete as per specifications. MORTH Specification No. 308.2 quintal 1100.00

19.92 KSRRB M300-Supplying sludge KSRRB M300-13. Supplying sludge duly


stacked at site/store complete as per specifications. MORTH Specification cum 207.00
No. 308.2
19.93 KSRRB M300- Half brick circular tree guard KSRRB M300-14. Half brick
circular tree guard, in 2nd class brick, internal diametre 1.25 metres, and
height 1.2 metres, above ground and 0.20 metre below ground, bottom two
courses laid dry, and top three courses in cement mortar 1:6 (1 cement 6 Each 2015.00
sand) and the intermediate courses being in dry honey comb masonry, as
per design complete, complete as per specifications.

19.94 KSRRB M300-Edging with 2nd class bricks, laid dry lengthwise KSRRB
M300-15. Edging with 2nd class bricks, laid dry lengthwise, including
excavation, refilling, consolidation, with a hand packing and spreading m 41.00
nearly surplus earth within a lead of 50 metres complete as per
specifications.
19.95 KSRRB M300- Making tree guard from empty bitumen drums KSRRB
M300-16. Making tree guard 53 cm dia and 1.3 m high as per design from
empty bitumen drum, slit suitably to permit sun and air, (supplied by the
department at stock issue rate) including providing and fixing 2 nos MS Each 374.00
sheet rings 50 x 0.5 mm with rivets, complete in all respect complete as per
specifications.

19.96 KSRRB M300-17. Making tree guard 53 cm dia and 2 metres high as per
design from empty bitumen drums, slit suitably to permit sun and air,
(supplied by the department at stock issue rate) including providing and
fixing four legs 40 cm long of 30 x 3 mm MS riveted to tree guard and Each 704.00
providing and fixing 2 nos. MS sheet rings 50 x 0.5 mm with rivets
complete in all respects complete as per specifications.

19.97 KSRRB M300- Wrought iron and mild steel welded work KSRRB M300-18.
Wrought iron and mild steel welded work (using angles, square bars, tees
and channel grills, grating frames, gates and tree guards of any size and
design etc. including cost of screens and welding rods or bolts and nuts quintal 7187.00
complete fixed in position but without the cost of excavation and concrete
for fixing which will be paid separately complete as per specifications.

Page No. 150


19.98 KSRRB M300-Tree guard with MS iron KSRRB M300-19. Providing and
fixing MS iron tree guard 60 cm dia and 2 metre high above ground level
formed of 4 Nos (25 x 6 mm) and 8 Nos (25 x 3 mm) vertical MS riveted to 3
Nos (25 x 6 mm) iron rings in two halves, bolted together with 8 mm dia Each 1805.00
and 30 mm long bolts including painting two coats with paint of approved
brand over a coat of priming, complete in all respects, complete as per
specifications.

19.100 KSRRB M300-Tree gaurd with MS Angle and Steel wire KSRRB M300-20.
Providing and fixing tree gaurd 0.60 metre square, 2.00 metre high
fabricated with MS angle iron 30 x 30 x 3 mm, MS iron 25 x 3 mm and steel Each 2326.00
wire 3 mm dia welded and fabricated as per design in two halves bolted
together complete as per specifications
19.101 KSRRB M300-Compensatory afforestation KSRRB M300-21. Planting trees
as compensatory afforestation at the rate of 290 trees per hectare at a
spacing of 6 m by grubbing and leveling the ground upto a depth of 150 Ha 76387.00
mm, digging holes 0.9 m dia, 1 m deep, mixing farm yard/sludge manure
with soil, planting of saple.

Page 115 of 375


19.102 Milling the bituminous pavement surface upto a depth of 55 mm using
milling machine, to make a uniform surface without disturbing the base,
cleaning the milled surface, including cost of all labour charges and hire Sqm 70.00
charges of machineries etc complete., including stacking the milled material
on the sides of road.
Note for item 19.102
1 For any additional depth over and above 55mm, rate shall be worked out on
pro-rata basis
2 Lead charges for the disposal of milled material shall be worked out as per
note 1 indicated in chapter-17, The lead charges shall be allowed only with
prior approval of Executive Engineer.
3 In case there is a stituation where the cross-section is of cut and fill and
cut earth wis required to be used in embankment in the immediate
vicinity.
4 KSRRB 300-26.2 : Note : For lead beyond 500 m earthwork shall be payable
at carriage rates by mechanical transport. There rate also include
earthwork excavation in ordinary soil including and unloading.

Page No. 151

20.0 SUB BASES-BASES (NON BITUMINOUS) AND SHOULDERS


20.1 KSRRB 400- Granular Sub-base KSRRB 400-1. Providing, laying, spreading
and compacting inverted choke of screening Type ‘ B ‘ or sand in sub-base
course in uniform layer on a prepared base by mechanical means with
motor grader and compacting with power roller including cost of all cum 2317.00
materials, labour, HOM of machineries complete as per specifications.
MORTH Chapter 4

20.2 KSRRB 400-2. Providing, laying, spreading and compacting specified


graded sand, gravel or any other course material 60% and crushed stone
aggregates of granite / trap / basalt 40% in sub-base course including
premixing the material at OMC in mechanical mixer (Pug mill), carriage of
mixed material up to 1km, spreading in uniform layers with motor grader
on a prepared base and compacting with power roller to achieve the desired cum 1248.00
density including all materials, labour, HOM of machinery, lighting,
guarding, barricading and maintenance of diversion complete as per
specifications. MORTH Chapter 4

20.5 Construction of granular sub-base Grading-V as sub-base and drainage


layer by providing coarse graded crushed stone aggregates of
granite/trap/basalt material, mixing in a mechanical mix plant at OMC,
carriage of mixed material to work site, spreading in uniform layers with cum 1882.00
motor grader on prepared surface and compacting with vibratory power
roller to achieve the 98% proctor density, complete as per specifications.
Clause 401 of MORTH V Revision.

20.6 Construction of granular sub-base Grading-V as sub-base and drainage


layer by providing coarse graded crushed stone aggregates of
granite/trap/basalt material, mixing in a mechanical mix plant at OMC,
spreading in uniform layers with motor grader on prepared surface and cum 1750.00
compacting with vibratory power roller to achieve the 98% proctor density,
complete as per specifications. Clause 401 of MORTH V Revision.

20.7 KSRRB M400- Lime stabilization for improving subgrade KSRRB M400-8.1.
Laying and spreading available soil in the subgrade on a prepared surface,
pulverising, mixing the spread soil in place with rotavator with 3 per cent
slaked lime having minimum content of 70 per cent of CaO, grading with
motor grader and compacting with the road roller at OMC to the desired cum 380.00
density to form a layer of improved subgrade complete as per specifications.
A. By Mechanical means MORTH Specification No. 402

Page No : 153
20.8 KSRRB M400-8.2. Lime Stabilisation for improving Subgrade Laying and
spreading available soil in the subgrade on a prepared surface, pulverising,
mixing the spread soil in place with rotavator with 3 per cent slaked lime
having minimum content of 70 per cent of CaO, grading with motor grader
and compacting with the road roller at OMC to the desired density to form a cum 446.00
layer of improved subgrade. complete as per specifications. B. By Manual
means MORTH Specification No. 402

Page 116 of 375


20.9 KSRRB M400- Lime Treated Soil for Sub-Base KSRRB M400-9. Providing,
laying and spreading soil on a prepared subgrade, pulverising, mixing the
spread soil in place with rotavator with 3% slaked lime with minimum
content of 70 per cent of CaO, grading with motor grader and compacting cum 476.00
with the road roller at OMC to achieve atleast 98% of the maximum dry
density to form a layer of sub-base complete as per specifications. MORTH
Specification No. 402

20.10 KSRRB M400-Cement Treated Soil Sub-Base/Base KSRRB M400-10.


Providing, laying and spreading soil on a prepared subgrade, pulverising,
adding the designed quantity of cement to the spread soil, mixing in place
with the rotavator, grading with the motor grader and compacting with the
road roller at OMC to achieve the desired unconfined compressive strength cum 788.00
and to form a layer of sub-base/base complete as per specifications. ( For
4% quantity of cement by weight of soil). MORTH Specification No. 403

20.11.1 KSRRB M400-Cement Treated Crushed rock or Combination as per Clause


403.2 & Table 400.4 in Sub-Base/Base KSRRB M400-11. Providing, laying
and spreading material on a prepared subgrade, adding the Designed
quantity of cement to the spread material, mixing in place with the
rotavator, grading with the motor grader and compacting with the road
roller at OMC to achieve the desired unconfined compressive strength and
cum 2398.00
to form a layer of sub-base/base complete as per specifications. (Quantity
of cement assumed as 4% of quantity of crushed rock by weight) MORTH
Specification No. 403 - Cement at site at 4% by wt. of crushed aggregate
(600 tonne) Grading of material for sub-base course

20.11.2 KSRRB M400-Cement Treated Crushed rock or Combination as per Clause


403.2 & Table 400.4 in Sub-Base/Base KSRRB M400-11. Providing, laying
and spreading material on a prepared subgrade, adding the Designed
quantity of cement to the spread material, mixing in place with the
rotavator, grading with the motor grader and compacting with the road
roller at OMC to achieve the desired unconfined compressive strength and
cum 2359.00
to form a layer of sub-base/base complete as per specifications. (Quantity
of cement assumed as 4% of quantity of crushed rock by weight) MORTH
Specification No. 403 - Cement at site at 4% by wt. of crushed aggregate
(600 tonne) Grading of material for base course

Page No : 154
20.14.1 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing,
laying, spreading and compacting crushed stone aggregates of granite /
trap / basalt specific sizes to water bound macadam specifications
including spreading in uniform thickness, hand packing, rolling with 3-
wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding cum 2192.00
materials to fill up the interstices of coarse aggregates, watering and
compacting to the required density complete as per Specification. A. By
mannual means. MORTH Specification No. 404 - Type A 13.2mm for
grading II

20.14.2 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing,


laying, spreading and compacting crushed stone aggregates of granite /
trap / basalt specific sizes to water bound macadam specifications
including spreading in uniform thickness, hand packing, rolling with 3-
wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding cum 2049.00
materials to fill up the interstices of coarse aggregates, watering and
compacting to the required density complete as per Specification. A. By
mannual means. MORTH Specification No. 404 - Crushable type such as
Moorum or Gravel for grading II

20.14.3 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing,


laying, spreading andcompacting crushed stone aggregates of granite / trap
/ basalt specific sizes to water bound macadam specifications including
spreading in uniform thickness, hand packing, rolling with 3- wheeled
steel/vibratory roller 8-10 tonnes in stages to proper grade and camber,
applying and brooming requisite type of screening/binding materials to fill cum 2322.00
up the interstices of coarse aggregates, watering and compacting to the
required density complete as per Specification. A. By mannual means.
MORTH Specification No. 404 - Type B 11.2mm for grading III

Page 117 of 375


20.14.4 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing,
laying, spreading and compacting crushed stone aggregates of granite /
trap / basalt specific sizes to water bound macadam specifications
including spreading in uniform thickness, hand packing, rolling with 3-
wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding cum 2074.00
materials to fill up the interstices of coarse aggregates, watering and
compacting to the required density complete as per Specification. A. By
mannual means. MORTH Specification No. 404 - Crushable type such as
Moorum or Gravel for grading III

20.16 KSRRB M400- Crushed cement sub-base/base KSRRB M400- 15. Breaking
and crushing of material obtained by breaking damaged cement concrete
slabs to size range not exceeding 75mm as specified in Table 400.7
transporting the aggregate obtained from breaking of cement concrete slabs
, laying and compacting the same as sub-base / base course, constructed cum 274.00
as WBM to Clause 400.4 except the use of screening or binding material
complete as per specifications. MORTH Specification No. 405

20.17 KSRRB M400- Penetration Coat over top layer of crushed cement concrete
base KSRRB M400-16. Spraying of bitumen over cleaned dry surface of
crushed cement concrete base at the rate of 25 kg per 10 sqm by a bitumen
pressure distributor, spreading of key aggregates at the rate of 0.13 cum Sqm 136.00
per 10 sqm by a mechanical gritter and rolling the surface as per Clause
500.6.3.8 complete as per specifications MORTH Specification No. 405.2

20.18 KSRRB M400- Wet Mix Macadam KSRRB M400-17. Providing, laying,
spreading and compacting crushed stone aggregates of granite / trap /
basalt to wet mix macadam specifications including pre mixing the material
with water at OMC in mechanical mix plant carriage of mixed method of
tipper to site, laying in uniform layers with paver in sub-base/base course cum 1888.00
on well prepared surface and compacting with vibratory roller to achieve the
desired density complete as per specifications. MORTH Specification No.
406

20.19 KSRRB M400-Construction of Median and Island with soil taken from
Roadway cutting KSRRB M400-18. Construction of Median and island
above road level with approved material deposited at site from roadway
cutting and excavation for drain and foundation of other structures, spread, cum 175.00
graded and compacted as per Clause 400.7 complete as per specifications.
MORTH Specification No. 407

20.20 KSRRB M400-Construction of Median and island with Soil taken from
Borrow Areas. KSRRB M400-19. Construction of Median and island with
Soil taken from Borrow Areas. Construction of Median and island above
road level with approved material deposited from borrowpits, spread, sloped cum 209.00
and compacted as per Clause 400.7 complete as per specifications. MORTH
Specification No. 407

20.21 KSRRB M400-Construction of footpath and separator KSRRB M400-21.


Construction of footpath/separator by providing a 150 mm compacted
granular sub-base as per Clause 401 & 25mm thick cement concrete grade
M-15, overlaid with precast concrete tiles in cement mortar 1:3 including Sqm 689.00
provision of all drainage arrangements but excluding kerb channel
complete as per specifications. MORTH Specification No. 409

Page No : 155
20.26 KSRRB M400- Lime, Flyash stabilised Soil Sub-base. KSRRB M400-23.
Lime, Flyash stabilised Soil Sub-base. Construction of sub-base using lime-
flyash admixture with granular soil, free from organic matter/deleterious
material or clayey silts and low plasticity clays having PI between 5 & 20
and liquid limit less than 25 and commercial dry lime slaked at site or pre-
slaked with CaO content not less than 50%, flyash to conform to gradation
as per Clause 43 of IRC: 88-1984, lime + flyash content ranging between 10 cum 362.00
to 30%, the minimum un-confined compressive strength and CBR value
after 28 days curing and 4 days soaking to be 7.5 kg/sqcm and 25%
respectively, all as specified in IRC:88-1984 complete as per specifications.

Note : KSRRB-400-2,4
Note : 1) This Analysis provides for median and island earthen top. In case
the surface is required to be turfed or planted with shrubs, the same is
required to be provided separately.
Note : 2. : KSRRB M 400-20. Construction of Shoulders
A. Earthen shoulders, The rate as applicable for sub-grade construction
may be adopted.

Page 118 of 375


B. Hard Shoulders Rate as applicable for sub-base and or base may be
adopted as per approved design.
C. Paved Shoulders. The rate may be adopted as applicable for different
layers of pavement depending upon approved design of paved shoulders.

Note : 3) Cost of flyash has not been considered as same will be available
free of cost. Only carrige of flyash has been provided.
Note : 4) Lime + Flyash has been taken as 20% of total mass and ration of
lime and flyash as 1:4 for estimating purposes. Total quantities will be as
per approved design .
Note : 5) Ground granulated blast furance slog/slag sand may be used for
item No.20.120.2,20.3,20.4,20,5 20,6, instead of river sasnd, grit and 6mm
below aggregates or in combinations.
Page No. 156

21.0 BASE AND SURFACE COURSES (BITUMINOUS)

21.1 KSRRB 500-1. Cleaning the existing WBM road surface including
removing of binding materials and other foreign matter with wire brushes
and small picks, sweeping with brooms or soft brushes and finally dusting
with old gunny bags and / or compressed air, to receive bituminous Sqm 21.00
treatment including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH specification clause 501

21.2 KSRRB 500-2. Cleaning the existing black topped surface with brooms, soft
brushes and finally dusting with old gunny bags and / or compressed air to
receive bituminous treatment including cost of all materials, labour, HOM Sqm 5.00
of machineries complete as per specifications. MORTH specification clause
501
21.3 KSRRB 500-3. Scarifying existing stone metal layer upto 75mm thick
along with their bituminous surface, picking up scarified materials and
stacking of old serviceable materials with lead of 100 m. sequential
spreading of the salvaged aggregates with fresh aggregates on prepared
base and consolidating as per water bound macadam specifications Sqm 126.00
including cost of all labour, HOM of machineries complete as per
specifications. MORTH specification clause 501

21.5 Providing and applying primer coat for surfaces of medium porosity like
cement stabilized soil base @ 1.10kg/sqmt over prepared surface with S.S
bitumen emulsion using bitumen tanker fitted with spray set (excluding
cleaning of road surface) including cost of all material, labour, HOM of Sqm 44.00
machineries complete as per specifications.. MORTH Chapter 5

21.6 KSRRB M500-6. Providing and applying primer coat with S.S. bitumen
emulsion on prepared surface of granular base such as WMM including
cleaning of road surface and spraying primer at the rate of 0.60 kg / sqm Sqm 34.00
using mechanical means complete as per specifications. MORTH
Specification No. 502
21.7 KSRRB 500-7. Providing and applying tack coat using 80/100 grade
bitumen(VG10) on the prepared black topped surfaces at 2.5 kg per 10
sqm, heating bitumen in boiler fitted with spray set (excluding cleaning of Sqm 14.00
road surface) including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH/Chapter 5
21.9 KSRRB 500-9. Providing and applying tack coat using 80/100 grade
bitumen (VG10) on granular base such as WBM surfaces hot bitumen
primed at 4 kg per 10 sqm, heating bitumen in boiler fitted with spray set
(excluding cleaning of road surface) including cost of all materials, labour, Sqm 23.00
HOM of machineries complete as per specifications. MORTH / Chapter 5

Page No. 158


21.10 KSRRB M500-10. Providing and applying tack coat using 80/100 grade
bitumen(VG10) in boiler fitted with spray set distributor at the rate of
0.25 kg per sqm on the existing prepared bituminous surface (primed
surface) cleaned with mchancial broom. complete as per specifications. Sqm 12.00

Page 119 of 375


21.11.1 KSRRB 500-11. Providing and laying bituminous macadam on prepared
surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E. loader, hot
mixing of stone aggregates and bitumen in hot mix plant, transporting the
mixd material in tipper to paver and laying mixed materials with paver
finisher to the required level and grade, rolling by power roller to achieve
cum 5863.00
the desired density, but excluding cost of primer / tack coat including lead,
lift and cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH /Chapter 5 - using 100/120 TPH capacity H.M.P.
with sensor paver Gr-1 (80 mm to 100mm) with 3.1 % VG-30 Bitumen

21.11.2 KSRRB 500-11. Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E. loader, hot
mixing of stone aggregates and bitumen in hot mix plant, transporting the
mixd material in tipper to paver and laying mixed materials with paver
finisher to the required level and grade, rolling by power roller to achieve
cum 6318.00
the desired density, but excluding cost of primer / tack coat including lead,
lift and cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH /Chapter 5 - using 100/120 TPH capacity H.M.P.
with sensor paver Gr-II (50 mm to 75 mm) with 3.3 % VG-30 Bitumen

21.11.3 KSRRB 500-11. Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E. loader, hot
mixing of stone aggregates and bitumen in hot mix plant, transporting the
mixd material in tipper to paver and laying mixed materials with paver
finisher to the required level and grade, rolling by power roller to achieve
cum 5734.00
the desired density, but excluding cost of primer / tack coat including lead,
lift and cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH /Chapter 5 - using 40/60 TPH capacity H.M.P. with
sensor paver Gr-I (80 mm to 100 mm) with 3.1 % VG-30 Bitumen

21.11.4 KSRRB 500-11. Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E. loader, hot
mixing of stone aggregates and bitumen in hot mix plant, transporting the
mixd material in tipper to paver and laying mixed materials with paver
finisher to the required level and grade, rolling by power roller to achieve
cum 5866.00
the desired density, but excluding cost of primer / tack coat including lead,
lift and cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH /Chapter 5 - using 40/60 TPH capacity H.M.P. with
sensor paver Gr-II (50 mm to 75 mm) with 3.3 % VG-30 Bitumen

21.11.5 KSRRB 500-11. Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E. loader, hot
mixing of stone aggregates and bitumen in hot mix plant, transporting the
mixd material in tipper to paver and laying mixed materials with paver
finisher to the required level and grade, rolling by power roller to achieve
cum 5691.00
the desired density, but excluding cost of primer / tack coat including lead,
lift and cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH /Chapter 5 - using 40/60 TPH capacity H.M.P. with
Mechanical paver Gr-I (80 mm to 100 mm) with 3.1 % VG-30 Bitumen

21.11.6 KSRRB 500-11. Providing and laying bituminous macadam on prepared


surface with crushed coarse aggregates as per design mix formula for
base / binding course including loading of aggregates with F.E. loader, hot
mixing of stone aggregates and bitumen in hot mix plant, transporting the
mixd material in tipper to paver and laying mixed materials with paver
finisher to the required level and grade, rolling by power roller to achieve
cum 5823.00
the desired density, but excluding cost of primer / tack coat including lead,
lift and cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH /Chapter 5 - using 40/60 TPH capacity H.M.P. with
Mechanical paver Gr-II (50 mm to 75 mm) with 3.3 % VG-30 Bitumen

Page 120 of 375


21.12 KSRRB 500-12. Providing, laying and consolidating of crushed stone
aggregates on prepared surface as per built up spray grout specifications
75mm thick, as base course compacted in two layers composite
construction of crushed stone aggregates with application of bitumen
binder after each layer and lay aggregate on the top of second layer and Sqm 385.00
rolling with power roller 8 to 10 tonne but excluding cost of primer / tack
coat including cost of all materials, labour, HOM of machineries complete
as per specifications.MORTH clause No. 506

Page No. 159


21.17.1 KSRRB M500-17. Providing and laying dense graded bituminous
macadam using crushed aggregates of specified grading, premixed with
VG30 grade bituminous binder and, transporting the hot mix to work site,
laying to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 6870.00
per MORTH table 500-10 complete in all respects complete as per
specifications.. MORTH Specification No. 507 - using 100/120 TPH capacity
H.M.P. with sensor paver Gr-1 (80 mm to 100mm) with 4 % VG-30 Bitumen

21.17.2 KSRRB M500-17. Providing and laying dense graded bituminous


macadam using crushed aggregates of specified grading, premixed with
VG30 grade bituminous binder and, transporting the hot mix to work site,
laying to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7464.00
per MORTH table 500-10 complete in all respects complete as per
specifications.. MORTH Specification No. 507 -using 100/120 TPH capacity
H.M.P. with sensor paver Gr-II (50 mm to 75 mm) with 4.5 % VG-30
Bitumen

21.17.3 KSRRB M500-17. Providing and laying dense graded bituminous


macadam using crushed aggregates of specified grading, premixed with
VG30 grade bituminous binder and, transporting the hot mix to work site,
laying to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 6734.00
per MORTH table 500-10 complete in all respects complete as per
specifications.. MORTH Specification No. 507 - using 40/60 TPH capacity
H.M.P. with sensor paver Gr-I (80 mm to 100 mm) with 4 % VG-30 Bitumen

21.17.4 KSRRB M500-17. Providing and laying dense graded bituminous


macadam using crushed aggregates of specified grading, premixed with
VG30 grade bituminous binder and, transporting the hot mix to work site,
laying to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7329.00
per MORTH table 500-10 complete in all respects complete as per
specifications.. MORTH Specification No. 507 - using 40/60 TPH capacity
H.M.P. with sensor paver Gr-II (50 mm to 75 mm) with 4.5 % VG-30
Bitumen

21.17.5 KSRRB M500-17. Providing and laying dense graded bituminous


macadam using crushed aggregates of specified grading, premixed with
VG30 grade bituminous binder and, transporting the hot mix to work site,
laying to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 6687.00
per MORTH table 500-10 complete in all respects complete as per
specifications.. MORTH Specification No. 507 - using 40/60 TPH capacity
H.M.P. with Mechanical paver Gr-I (80 mm to 100 mm) with 4 % VG-30
Bitumen

21.17.6 KSRRB M500-17. Providing and laying dense graded bituminous


macadam using crushed aggregates of specified grading, premixed with
VG30 grade bituminous binder and, transporting the hot mix to work site,
laying to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7284.00
per MORTH table 500-10 complete in all respects complete as per
specifications.. MORTH Specification No. 507 - using 40/60 TPH capacity
H.M.P. with Mechanical paver Gr-II (50 mm to 75 mm) with 4.5 % VG-30
Bitumen

21.20.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7461.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 100/120 TPH capacity H.M.P. with sensor
paver Gr-I (35 mm to 40 mm) with 4.5 % VG-30 Bitumen

Page 121 of 375


21.20.2 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7997.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 100/120 TPH capacity H.M.P. with sensor
paver Gr-II (25 mm to 30 mm) with 5 % VG-30 Bitumen

21.20.3 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7328.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40/60 TPH capacity H.M.P. with sensor paver
Gr-I (35 mm to 40mm) with 4.5 % VG-30 Bitumen

21.20.4 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7866.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using40/60 TPH capacity H.M.P. with sensor paver
Gr-II (25 mm to 30 mm) with 5 % VG-30 Bitumen

21.20.5 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7281.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using40/60 TPH capacity H.M.P. with Mechanical
Paver Gr-I (35 mm to 40 mm) with 4.5 % VG-30 Bitumen

21.20.6 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7821.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using40/60 TPH capacity H.M.P. with Mechanical
Paver Gr-II (25 mm to 30 mm) with 5 % VG-30 Bitumen

21.20.7 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7364.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 100/120 TPH capacity H.M.P. with sensor
paver Gr-I (35 mm to 40 mm) with 4.5 % VG-10 Bitumen

21.20.8 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7893.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 100/120 TPH capacity H.M.P. with sensor
paver Gr-II (25 mm to 30 mm) with 5 % VG-10 Bitumen

21.20.9 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7228.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40/60 TPH capacity H.M.P. with sensor paver
Gr-I (35 mm to 40mm) with 4.5 % VG-10 Bitumen

Page 122 of 375


21.20.10 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7758.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using40/60 TPH capacity H.M.P. with sensor paver
Gr-II (25 mm to 30 mm) with 5 % VG-10 Bitumen

21.20.11 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7376.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using40/60 TPH capacity H.M.P. with Mechanical
Paver Gr-I (35 mm to 40 mm) with 4.5 % VG-10 Bitumen

Page No. 160


21.20.12 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7713.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using40/60 TPH capacity H.M.P. with Mechanical
Paver Gr-II (25 mm to 30 mm) with 5 % VG-10 Bitumen

21.21.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7595.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. do - using 100-120 TPH capacity H.M.P. with sensor
paver grading I (35-40mm) with 4.5% CRMB-55 grade

21.21.2 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 8151.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 100-120 TPH capacity H.M.P. with sensor
paver grading II (25-30mm) with 5% CRMB-55 grade

21.21.3 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7462.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with sensor paver
grading I (35-40mm) with 4.5% CRMB-55 grade

21.21.4 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 8015.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with sensor paver
grading II (25-30mm) with 5% CRMB-55 grade

Page 123 of 375


21.21.5 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7416.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with mechanical
paver grading I (35 -40mm) with 4.5% CRMB-55 grade

21.21.6 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 7970.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with mechanical
paver grading II (25-30mm) with 5% CRMB-55 grade

21.21.7 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 9048.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 100-120 TPH capacity H.M.P. with sensor
paver grading I (35-40mm) with 4.5% NRMB 70 / PMB 70 grade

21.21.8 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 9765.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 100-120 TPH capacity H.M.P. with sensor
paver grading II (25-30mm) with 5% NRMB 70/ PMB 70 grade

21.21.9 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 8912.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with sensor paver
grading I (35-40mm) with 4.5% NRMB 70/ PMB 70 grade

21.21.10 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 9630.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with sensor paver
grading II (25-30mm) with 5% NRMB 70/ PMB 70 grade

21.21.11 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 8867.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with mechanical
paver grading I (35-40mm) with 4.5% NRMB 70/ PMB 70 grade

21.21.12 KSRRB M500-18. Providing and laying semi dense bituminous concrete
using crushed aggregates of specified grading, premixed with bituminous
binder and filler, transporting the hot mix to work site, laying with a paver
finisher to the required grade, level and alignment, rolling with smooth
wheeled, vibratory and tandem rollers to achieve the desired compaction as cum 9585.00
per MORTH specification clause No. 508 complete in all respects complete
as per specifications. - using 40-60 TPH capacity H.M.P. with mechanical
paver grading II (25-30mm) with 5% NRMB 70/ PMB 70 grade

Page 124 of 375


Page No. 161
21.22.1 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick
with hot mix plant, using crushed aggregates of specified grading, premixed
with bituminous binder and filler, transporting the hot mix to work site,
laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the
desired compaction as per MORTH specification clause No. 500.9 complete cum 8367.00
in all respects complete as per specifications. MORTH Specification No. 509
- using 100/120 TPH capacity H.M.P. with sensor paver Gr-I (50 to 65 mm)
with 5.5 % VG-30 Bitumen

21.22.2 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick


with hot mix plant, using crushed aggregates of specified grading, premixed
with bituminous binder and filler, transporting the hot mix to work site,
laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the
desired compaction as per MORTH specification clause No. 500.9 complete cum 8656.00
in all respects complete as per specifications. MORTH Specification No. 509
- using 100/120 TPH capacity H.M.P. with sensor paver Gr-II (30 mm to 45
mm) with6 % VG-30 Bitumen

21.22.3 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick


with hot mix plant, using crushed aggregates of specified grading, premixed
with bituminous binder and filler, transporting the hot mix to work site,
laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the
desired compaction as per MORTH specification clause No. 500.9 complete cum 8230.00
in all respects complete as per specifications. MORTH Specification No. 509
- using 40/60 TPH capacity H.M.P. with sensor paver Gr-I (50 mm to
60mm) with 5.5 % VG-30 Bitumen

21.22.4 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick


with hot mix plant, using crushed aggregates of specified grading, premixed
with bituminous binder and filler, transporting the hot mix to work site,
laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the
desired compaction as per MORTH specification clause No. 500.9 complete cum 8518.00
in all respects complete as per specifications. MORTH Specification No. 509
- using40/60 TPH capacity H.M.P. with sensor paver Gr-II (30 mm to 45
mm) with 6 % VG-30 Bitumen

21.22.5 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick


with hot mix plant, using crushed aggregates of specified grading, premixed
with bituminous binder and filler, transporting the hot mix to work site,
laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the
desired compaction as per MORTH specification clause No. 500.9 complete cum 8184.00
in all respects complete as per specifications. MORTH Specification No. 509
- using 40-60 TPH capacity H.M.P. with mechanical paver grading I (50-
65mm) with 5.5%VG-30 Bitumen

21.22.6 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick


with hot mix plant, using crushed aggregates of specified grading, premixed
with bituminous binder and filler, transporting the hot mix to work site,
laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the
desired compaction as per MORTH specification clause No. 500.9 complete cum 8472.00
in all respects complete as per specifications. MORTH Specification No. 509
- using40/60 TPH capacity H.M.P. with Mechanical Paver Gr-II (30 mm to
45 mm) with 6 % VG-30 Bitumen

21.23.1 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 8525.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using 100/120 TPH capacity H.M.P. with sensor paver
Gr-I (50 to 65mm) with 5.5 % CRMB 55

Page 125 of 375


21.23.2 KSRRB M500-19. Providing and laying bituminous concrete using
crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 8822.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using 100/120 TPH capacity H.M.P. with sensor paver
Gr-II (30 mm to 45 mm) with6 % CRMB 55

21.23.3 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 8389.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using 40/60 TPH capacity H.M.P. with sensor paver Gr-
I (50 mm to 60mm) with 5.5 % CRMB 55

21.23.4 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 8685.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using40/60 TPH capacity H.M.P. with sensor paver Gr-
II (30 mm to 45mm) with 6 % CRMB 55

21.23.5 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 8343.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using 40-60 TPH capacity H.M.P. with mechanical
paver grading I (50 -65mm) with 5.5% CRMB-55 grade

21.23.6 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 8639.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using40/60 TPH capacity H.M.P. with Mechanical
Paver Gr-II (30 mm to 45 mm) with 6 % CRMB 55

21.23.7 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 10232.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using 100/120 TPH capacity H.M.P. with sensor paver
Gr-I (50 to 65 mm) with 5.5 % NRMB 70/ PMB 70

21.23.8 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 10617.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications.- using 100/120 TPH capacity H.M.P. with sensor paver
Gr-II (30 mm to 45 mm) with 6 % NRMB 70/ PMB 70

21.23.9 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 10096.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using 40/60 TPH capacity H.M.P. with sensor paver Gr-
I (50 mm to 60mm) with 5.5 %NRMB 70/PMB 70

Page 126 of 375


21.23.10 KSRRB M500-19. Providing and laying bituminous concrete using
crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 10481.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using40/60 TPH capacity H.M.P. with sensor paver Gr-
II (30 mm to 45 mm) with 6 % NRMB 70/ PMB 70

Page No. 162


21.23.11 KSRRB M500-19. Providing and laying bituminous concrete using
crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 10050.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using 40-60 TPH capacity H.M.P. with mechanical
paver grading I (50-65mm) with 5.5% NRMB 70/ PMB 70

21.23.12 KSRRB M500-19. Providing and laying bituminous concrete using


crushed aggregates of specified grading, premixed with bituminous binder
and filler, transporting the hot mix to work site, laying with paver finisher
to the required grade, level and alignment, rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desired compaction as per cum 10435.00
MORTH specification clause No. 509 complete in all respects complete as
per specifications. - using40/60 TPH capacity H.M.P. with Mechanical
Paver Gr-II (30 mm to 45 mm) with 6 % NRMB 70/ PMB 70

21.26 KSRRB 500-22. Providing and laying single coat surface dressing or first
coat of the two surface dressing with 0.15 cum/10 sqm crushed stone
chippings passing 19mm & retained on 13.20mm sieve as per Table 500-
21and bitumen 12 kg / 10 sqm of VG-10 (80/100) as wearing course
consisting of a layer of bituminous binder laid on the prepared surface Sqm 95.00
followed by cover of crushed stone chippings of specified size (may be pre-
coated also) and rolling with power roller 8-10 tonne capacity including cost
of all materials, labour, HOM of machineries complete as per specifications.
MORTHclause No.510

21.27 KSRRB 500-23. Providing and laying second coat surface dressing with
0.10 cum/10 sqm crushed stone chippings passing 13.2mm & retained on
9.50mm sieve as per Table 500-21and bitumen 10 kg / 10 sqm of VG-10
(80/100) as wearing course consisting of a layer of bituminous binder laid
on the prepared surface followed by cover of crushed stone chippings of Sqm 77.00
specified size (may be pre-coated also) and rolling with power roller 8-10
tonne capacity including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTHclause No.510

21.32 KSRRB 500-27. Providing and laying open graded premix carpet of 20mm
thick on prepared surface in a single course as wearing course composed of
11.2mm and 13.2mm size stone aggregates 0.027 cum/ sqm premixd with
bituminous binder at 1.46kg/sqm in mini hot mix plant 6-10 tonne
capacity laying manually and rolling with power roller 8-10 tonne, Sqm 139.00
excluding cost of tack coat, including cost of all materials, labour, HOM of
machineries complete as per specifications using VG 10 (80/100) grade.
MORTH clause No.511/Chapter 5

21.33 KSRRB 500-28. Providing and laying open graded premix carpet of 20mm
thick on prepared surface in a single course as wearing course composed of
11.2mm and 13.2mm size stone aggregates 0.027 cum/ sqm premixd with
bituminous binder at 1.46kg/sqm in mini hot mix plant 6-10 tonne
capacity laying manually and rolling with power roller 8-10 tonne, Sqm 142.00
excluding cost of tack coat, including cost of all materials, labour, HOM of
machineries complete as per specifications using VG 10 (80/100) grade.
MORTH clause No.511/Chapter 5.- (Using CRMB 55 grade)

Page 127 of 375


21.36 KSRRB 500-30. Providing and laying 20 mm thick mix seal surfacing
Type A on prepared surface as wearing course with specified graded
crushed aggregates of 5.6mm and 11.2mm size 0.027 cum/sqm premixd
with bituminous binder at 2.20kg/sqm), in hotmix plant 40/60 tonne,
transporting the mixed materials in tipper and laying with machanical
paver finisher to required level and grade, rolling with power roller 8-10 Sqm 155.00
tonne, excluding cost of tack coat including cost of all materials, labour,
HOM of machineries complete as per specifications. MORTH clause No.512
- using VG-30 (60/70 grade)

21.37 KSRRB 500-31. Providing and laying 20 mm thick mix seal surfacing
Type A on prepared surface as wearing course with specified graded
crushed aggregates of 5.6mm and 11.2mm size 0.027 cum/sqm premixd
with bituminous binder at 2.20kg/sqm), in hotmix plant 40/60 tonne,
transporting the mixed materials in tipper and laying with machanical
paver finisher to required level and grade, rolling with power roller 8-10 Sqm 158.00
tonne, excluding cost of tack coat including cost of all materials, labour,
HOM of machineries complete as per specifications. MORTH clause No.512
- using CRMB 55 grade Bitumen

Page No. 163


21.38 KSRRB 500-32. Providing and laying 20 mm thick mix seal surfacing
Type-B on prepared surface as wearing course with specified graded
crushed aggregates of 5.6mm and 13.2mm size 0.027 cum/sqm premixed
with bituminous binder at 1.90kg/sqm in hotmix plant 40/60 TPH,
transporting the mixed materials in tipper and laying with machanical
paver finisher to required level and grade, rolling with power roller 8-10 Sqm 144.00
tonne, excluding cost of tack coat including cost of all materials, labour,
HOM of machineries complete as per specifications. MORTH clause No.512
- using VG 30 (60/70 grade) bitumen

21.39 KSRRB 500-33. Providing and laying 20 mm thick mix seal surfacing
Type-B on prepared surface as wearing course with specified graded
crushed aggregates of 5.6mm and 13.2mm size 0.027 cum/sqm premixd
with bituminous binder at 1.90kg/sqm in hotmix plant 40/60 TPH,
transporting the mixed materials in tipper and laying with machanical
paver finisher to required level and grade, rolling with power roller 8-10 Sqm 146.00
tonne, excluding cost of tack coat including cost of all materials, labour,
HOM of machineries complete as per specifications. MORTH clause No.512
- - using CRMB 55 grade Bitumen

21.40 KSRRB 500-34. Providing and laying 20 mm thick mix seal surfacing Type
A on prepared surface in a single course composed of specified graded
crushed aggregates 5.6mm to 11.2mm size 0.027 cum/sqm premixd with
bitumen binder at 2.20 kg/sqm of in a minimix plant 6 /10 tonne
capacity, laying manually and rolling with power roller 8-10 tonne Sqm 171.00
excluding cost of tack coat including cost of all materials, labour, HOM of
machineries complete as per specifications. MORTH clause No.512 - using
VG-30 (60/70) bitumen

21.41 KSRRB 500-35. Providing and laying 20 mm thick mix seal surfacing Type
A on prepared surface in a single course composed of specified graded
crushed aggregates 5.6mm to 11.2mm size 0.027 cum/sqm premixd with
bitumen binder at 2.20 kg/sqm of in a minimix plant 6 /10 tonne
capacity, laying manually and rolling with power roller 8-10 tonne Sqm 174.00
excluding cost of tack coat including cost of all materials, labour, HOM of
machineries complete as per specifications. MORTH clause No.512 - -
using CRMB 55 grade Bitumen

21.42 KSRRB 500-36. Providing and laying 20 mm thick mix seal surfacing Type
‘ B ‘ on prepared surface in a single course composed of specified graded
crushed aggregates 5.6mm to 13.2mm size premixed with bitumen binder
@ 1.90 kg/sqm of VG-30 (60/70) in a minimix plant 6 / 10 tonne, laying
manually and rolling with power roller 8-10 tonne excluding cost of tack Sqm 164.00
coat including cost of all materials, labour, HOM of machineries complete
as per specifications . MORTH clause No.512

Page 128 of 375


21.43 KSRRB 500-37. Providing and laying 20 mm thick mix seal surfacing Type
‘ B ‘ on prepared surface in a single course composed of specified graded
crushed aggregates 5.6mm to 13.2mm size premixed with bitumen binder
@ 1.90 kg/sqm of CRMB 55 grade in a minimix plant 6 / 10 tonne, laying
manually and rolling with power roller 8-10 tonne excluding cost of tack Sqm 162.00
coat including cost of all materials, labour, HOM of machineries complete
as per specifications . MORTH clause No.512

Page No : 164
21.45.1 KSRRB M500- 39.1 and 39.2. Providing and laying SEAL COAT for sealing
the voids on Bituminous surface, laid to the specified levels, grade and
cross fall manually and rolling with power roller 8 - 10 tonne capacity
including cost of all materials, labour, HOM of machinery complete as per
the specifications. MORTH Specification No. 513 - TYPE A - using graded Sqm 58.00
aggregates 6.7mm and down size at 0.009 cum/sqm with bitumen binder
VG-10 (80/100 grade) at 0.98 kg/sqm.

21.45.2 KSRRB M500- 39.1 and 39.2. Providing and laying SEAL COAT for sealing
the voids on Bituminous surface, laid to the specified levels, grade and
cross fall manually and rolling with power roller 8 - 10 tonne capacity
including cost of all materials, labour, HOM of machinery complete as per
the specifications. MORTH Specification No. 513 -TYPE B - using graded Sqm 45.00
aggregates 2.36mm and down size at 0.006 cum/sqm with bitumen binder
VG-10 (80/100 grade) at 0.68 kg/sqm.

21.47 KSRRB M500- Mastic asphalt KSRRB M500-41. Providing and laying 25
mm thick mastic asphalt wearing course with paving grade bitumen@
5.82 kg/sqmt meeting the requirements given in table 500-29, prepared by
using mastic cooker and laid to required level and slope after cleaning the
surface, including providing antiskid surface with bitumen precoated fine
grained hard stone chipping of 13.2 mm nominal size at the rate of
0.005cum per 10 sqm and at an approximate spacing of 10 cm center to Sqm 741.00
center in both directions, pressed into surface when the temperature of
surfaces is not less than 100°C, protruding 1 mm to 4 mm over mastic
surface, complete as per clause 500.15 as per specifications. MORTH
Specification No. 515

21.53 KSRRB M500-48. Providing and applying slow setting bitumen emulsion@at
0.75 kg/sqm for sealing cracks less than 3 mm wide or incipient fretting or
disintegration in an existing bituminous surfacing complete as per Sqm 43.00
specifications. MORTH Specification No. 518
21.55 KSRRB M500-49.1. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified
grades and levels complete as per specifications. Case - I : using bitumen cum 12913.00
emulsion at 175 kgs/cum & 9.5mm or 13.2mm nominal size aggregate”
MORTH Specification No. 519

21.56 KSRRB M500-49.2. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified
grades and levels complete as per specifications.Case - II : using bitumen cum 11215.00
emulsion at 175 kgs/cum & 19mm to 26.5mm nominal size aggregate
MORTH Specification No. 519

21.57 KSRRB M500-49.3. Providing, laying and rolling of bituminous cold mix on
prepared base consisting of a mixture of unheated mineral aggregate and
emulsified or cutback bitumen, including mixing in a plant of suitable type
and capacity, transporting, laying, compacting and finishing to specified
grades and levels complete as per specifications. Case - III : using cutback cum 11711.00
bitumen at 110 kgs/cum & 9.5mm or 13.2mm nominal size aggregate .
MORTH Specification No. 519

21.64 KSRRB M500-56.1. Providing and laying slurry seal consisting of a mixture
of fine aggregates, portland cement filler, bituminous emulsion and water
on a road surface including cleaning of surface, mixing of slurry seal in a
suitable mobile plant, laying and compacting to provide even riding surface Sqm 28.00
Complete as per specifications. Case - I : 5mm thickness MORTH
Specification No. 516
Page No. 165

Page 129 of 375


21.65 KSRRB M500-56.2. -Providing and laying slurry seal consisting of a mixture
of fine aggregates, portland cement filler, bituminous emulsion and water
on a road surface including cleaning of surface, mixing of slurry seal in a
suitable mobile plant, laying and compacting to provide even riding surface Sqm 32.00
Complete as per specifications.- Case - II : 3mm thickness MORTH
Specification No. 516

21.66 KSRRB M500-56.3. Providing and laying slurry seal consisting of a mixture
of fine aggregates, portland cement filler, bituminous emulsion and water
on a road surface including cleaning of surface, mixing of slurry seal in a
suitable mobile plant, laying and compacting to provide even riding surface Sqm 31.00
Complete as per specifications.- Case - III : 1.5mm thickness MORTH
Specification No. 516

21.67 KSRRB M500-57.1. Providing and laying of a stress absorbing membrane


over a cracked road surface, with crack width below 6 mm after cleaning
with a mechanical broom, using modified binder complying with clause
521, sprayed at the rate of 9 kg per 10 sqm and spreading 5.6 mm crushed
stone aggregates at 0.11 cum per 10 sqm with hydraulic chip spreader, Sqm 66.00
sweeping the surface for uniform spread of aggregates and surface finished
to conform to clause 900.2 complete as per specification. Case - I :Stress
absorbing membrane (SAM) crack width less than 6mm MORTH
Specification No. 522

21.68 “KSRRB M500-57.2. Providing and laying of a stress absorbing membrane


over a cracked road surface, with crack width 6 to 9 mm after cleaning with
a mechanical broom, using modified binder complying with clause 521,
sprayed at the rate of 11 kg per 10 sqm and spreading 11.2 mm crushed
stone aggregates at 0.12 cum per 10 sqm, sweeping the surface for uniform Sqm 71.00
spread of aggregates and surface finished to conform to clause 900.2
complete as per specification. Case - II :Stress absorbing membrane (SAM)
crack width 6mm to 9mm” MORTH Specification No. 522

21.69 KSRRB M500-57.3. Providing and laying a single coat of a stress absorbing
membrane over a cracked road surface, with crack width above 9 mm and
cracked area above 50% after cleaning with a mechanical broom, using
modified binder complying with clause 521, sprayed at the rate of 15 kg per
10 sqm and spreading 11.2 mm crushed stone aggregates at 0.12 cum per
10 sqm, sweeping the surface for uniform spread of aggregates and surface Sqm 90.00
finished to conform to clause 900.2 complete as per specification. Case -
III :Stress absorbing membrane (SAM) crack width above 9 mm and cracked
aread above 50% MORTH Specification No. 522

Page No. 166


21.70 KSRRB M500-57.4. Providing and laying a bitumen impregnated geotextile
layer after cleaning the road surface, geotextile conforming to requirements
of clause 700.3.3, laid over a tack coat with 1.05 kg per sqm of paving
grade bitumen 80 - 100 penetration and constructed to the requirement of Sqm 124.00
clause 700.3.4.5 complete as per specification. Case - IV : Bitumen
impregnated geotextile MORTH Specification No. 522

21.71 KSRRB M500-Recipe Cold Mixes KSRRB M500-58.1. Providing and laying
of premix of crushed stone aggregates of 40 mm down size and emulsion
binder at 98 kgs/cum mixed in a batch type cold mixing plant, laid over
prepared surface, by paver finisher, rolled with a pneumatic tyred roller cum 6918.00
initially and finished with a smooth steel wheel roller, all as per clause
500.19.3 complete as per specifications. Case - I : 75 mm thickness
MORTH Specification No. 519.3

21.72 KSRRB M500-58.2. KSRRB M500-58.1. Providing and laying of premix of


crushed stone aggregates of 13.20 mm down size and emulsion binder at
153 kg/cum mixed in a batch type cold mixing
plant, laid over prepared surface, by paver finisher, rolled with a cum 9434.00
pneumatic tyred roller initially and finished with a smooth steel wheel
roller, all as per clause 500.19.3 complete as per specifications.- Case - II :
40 mm thickness MORTH Specification No. 519.3

21.73 KSRRB M500-58.3. KSRRB M500-58.1. Providing and laying of premix of


crushed stone aggregates 6.0mm down size and emulsion binder at 186
kgs/cum mixed in a batch type cold mixing plant, laid over prepared
surface, by paver finisher, rolled with a pneumatic tyred roller initially and cum 10872.00
finished with a smooth steel wheel roller, all as per clause 500.19.3
complete as per specifications. Case - III : 25 mm thickness MORTH
Specification No. 519.3

Page 130 of 375


21.74.1 KSRRB M500-47. Recycling pavement by cold milling of existing
bituminous layers, planing the surface after cold milling, reclaiming
excavated material to the extent of 30 per cent of the required quantity,
hauling and stock piling the reclaimed material near the central recycling
plant after carrying out necessary checks and evaluation, adding fresh
material including rejuvenators as required, mixing in a 40/60 TPH hot mix
plant, transporting to site and laying with mechanical paver and
compacting to the required grade, level and thickness including cost of all cum 5701.00
materials and labour etc., complete as specified in MORTH clause 517. -
using milling machine for DBM grade II (50mm to 75mm thick) using
bitumen binder VG-30 (60/70 grade) to achieve 4.50% bitumen content.

Page No : 167
21.74.2 KSRRB M500-47. Recycling pavement by cold milling of existing
bituminous layers, planing the surface after cold milling, reclaiming
excavated material to the extent of 30 per cent of the required quantity,
hauling and stock piling the reclaimed material near the central recycling
plant after carrying out necessary checks and evaluation, adding fresh
material including rejuvenators as required, mixing in a 40/60 TPH hot mix
plant, transporting to site and laying with mechanical paver and cum 5720.00
compacting to the required grade, level and thickness including cost of all
materials and labour etc., complete as specified in MORTH clause 517. -
Scarifying using roller attached scarifier - for DBM grade II (50mm to 75mm
thick) using bitumen binder VG-30 (60/70 grade) to achieve 4.50% bitumen
content.

21.74.3 KSRRB M500-47. Recycling pavement by cold milling of existing


bituminous layers, planing the surface after cold milling, reclaiming
excavated material to the extent of 30 per cent of the required quantity,
hauling and stock piling the reclaimed material near the central recycling
plant after carrying out necessary checks and evaluation, adding fresh
material including rejuvenators as required, mixing in a 40/60 TPH hot mix
plant, transporting to site and laying with mechanical paver and
compacting to the required grade, level and thickness including cost of all cum 4405.00
materials and labour etc., complete as specified in MORTH clause 517. -
using milling machine for BM grade II (50mm to 75mm thick) using
bitumen binder VG-30 (60/70 grade) to achieve 3.30% bitumen content

21.74.4 KSRRB M500-47. Recycling pavement by cold milling of existing


bituminous layers, planing the surface after cold milling, reclaiming
excavated material to the extent of 30 per cent of the required quantity,
hauling and stock piling the reclaimed material near the central recycling
plant after carrying out necessary checks and evaluation, adding fresh
material including rejuvenators as required, mixing in a 40/60 TPH hot mix
plant, transporting to site and laying with mechanical paver and cum 4424.00
compacting to the required grade, level and thickness including cost of all
materials and labour etc., complete as specified in MORTH clause 517. -
Scarifying using roller attached scarifier - for BM grade II (50mm to 75mm
thick) using bitumen binder VG-30 (60/70 grade) to achieve 3.30% bitumen
content.

21.75 Providing and laying 20 mm thick mix seal surfacing Type A on prepared
surface as wearing course with specified graded crushed aggregates of
5.6mm and 11.2mm size 0.027 cum/sqm premixd with modified
bituminous binder at 2.20 kg/sqm consisting of 2.024 kg of VG- 10
bitumen (80/100 grade) and Plastomeric Thermoplastics (Waste Plastic
Additive) @ 0.176 kg, in hotmix plant 40/60 TPH, transporting the mixed
Sqm 153.00
materials in tipper and laying with machanical paver finisher to required
level and grade, rolling with power roller 8-10 tonne, excluding cost of tack
coat, including cost of all materials, labour, HOM of machineries complete
as per specifications. MORTH clause No.512

Page 131 of 375


21.76 Providing and laying 20 mm thick mix seal surfacing Type B on prepared
surface as wearing course with specified graded crushed aggregates of
5.6mm and 13.2mm size 0.027 cum/sqm premixd with modified
bituminous binder at 1.90 kg/sqm consisting of 1.748 kg of VG- 10
bitumen (80/100 grade) and Plastomeric Thermoplastics (Waste Plastic
Additive) @ 0.152 kg, in hotmix plant 40/60 TPH, transporting the mixed
Sqm 147.00
materials in tipper and laying with machanical paver finisher to required
level and grade, rolling with power roller 8-10 tonne, excluding cost of tack
coat, including cost of all materials, labour, HOM of machineries complete
as per specifications.MORTH clause No.512

21.77.1 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per
cum 7236.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-1
(35 mm to 40 mm) with 4.5 % of modified bitumen binder consisting of VG-
10 Bitumen (80/100 grade) and 0.36% of Plastomeric Thermoplastics
(Waste plastic Additive).

Page No. 168


21.77.2 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7751.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-2
(25 mm to 30 mm) with 5 % of modified bitumen binder consisting of
Plastomeric Thermoplastics (Waste plastic Additive).

21.77.3 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7101.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-1 (35
mm to 40 mm) with 4.5 % of modified bitumen binder consisting of 4.14%
VG- 10 bitumen (80/100 grade) 0.36% Plastomeric Thermoplastics (Waste
plastic Additive).

21.77.4 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7616.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II
with 5 % of modified bitumen binder consisting of 4.60% VG- 10 bitumen
(80/100 grade) 0.4% Plastomeric Thermoplastics (Waste plastic Additive).

21.77.5 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7056.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I
(35-40mm) with 4.5 % of modified bitumen binder consisting of 4.14% VG-
10 bitumen (80/100 grade) 0.36% Plastomeric Thermoplastics (Waste
plastic Additive).

Page 132 of 375


21.77.6 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7571.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I (25-
30mm) with 5 % of modified bitumen binder consisting of 4.6% VG- 10
bitumen (80/100 grade) 0.40% Plastomeric Thermoplastics (Waste plastic
Additive).

21.77.7 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7328.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-1
(35 mm to 40 mm) with 4.5 % of modified bitumen binder consisting of VG-
30 Bitumen (60/70 grade) and 0.36% of Plastomeric Thermoplastics (Waste
plastic Additive).

21.77.8 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7853.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-II
(25 mm to 30 mm) with 5 % of modified bitumen binder consisting of VG-30
Bitumen (60/70 grade) and 0.40% Plastomeric Thermoplastics (Waste
plastic Additive).

21.77.9 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7192.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-1 (35
mm to 40 mm) with 4.5 % of modified bitumen binder consisting of 4.14%
VG- 30 bitumen (60/70 grade) 0.36% Plastomeric Thermoplastics (Waste
plastic Additive).

21.77.10 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7717.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II
with 5 % of modified bitumen binder consisting of 4.60% VG- 30 bitumen
(60/70 grade) 0.40% Plastomeric Thermoplastics (Waste plastic Additive).

21.77.11 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7147.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-I
(35-40mm) with 4.5 % of modified bitumen binder consisting of 4.14% VG-
30 bitumen (60/70 grade) 0.36% Plastomeric Thermoplastics (Waste plastic
Additive).

Page No. 169


21.77.12 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7672.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-
II (25-30mm) with 5 % of modified bitumen binder consisting of 4.60% VG-
30 bitumen (60/70 grade) 0.40% Plastomeric Thermoplastics (Waste plastic
Additive).

Page 133 of 375


21.78.1 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8120.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-I
(50-65mm) with 5.2 % of modified bitumen binder consisting of 4.78% VG-
10 bitumen (80/100 grade) 0.42% Plastomeric Thermoplastics (Waste
plastic Additive).

21.78.2 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8395.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-II
(30-45mm) with 5.4 % of modified bitumen binder consisting of 4.97% VG-
10 bitumen (80/100 grade) 0.43% Plastomeric Thermoplastics (Waste
plastic Additive).

21.78.3 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7675.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I
(50-65mm) with 5.2 % of modified bitumen binder consisting of 4.78% VG-
10 bitumen (80/100 grade) 0.42% Plastomeric Thermoplastics (Waste
plastic Additive).

21.78.4 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8257.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II
(30-45mm) with 5.4 % of modified bitumen binder consisting of 4.97% VG-
10 bitumen (80/100 grade) 0.43% Plastomeric Thermoplastics (Waste
plastic Additive).

21.78.5 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7826.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-I
(50-65mm) with 5.2 % of modified bitumen binder consisting of 4.78% VG-
10 bitumen (80/100 grade) 0.42% Plastomeric Thermoplastics (Waste
plastic Additive).

21.78.6 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8408.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-
II (30-45mm) with 5.4 % of modified bitumen binder consisting of 4.97%
VG- 10 bitumen (80/100 grade) 0.43% Plastomeric Thermoplastics (Waste
plastic Additive).

21.78.7 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8228.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-I
(50-65mm) with 5.2 % of modified bitumen binder consisting of 4.78% VG-
30 bitumen (60/70 grade) 0.42% Plastomeric Thermoplastics (Waste plastic
Additive).

Page No. 170

Page 134 of 375


21.78.8 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8509.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-II
(30-45mm) with 5.4 % of modified bitumen binder consisting of 4.97% VG-
10 bitumen (60/70 grade) 0.43% Plastomeric Thermoplastics (Waste plastic
Additive).

21.78.9 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7783.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I
(50-65mm) with 5.2 % of modified bitumen binder consisting of 4.78% VG-
30 bitumen (60/70 grade) 0.42% Plastomeric Thermoplastics (Waste plastic
Additive).

21.78.10 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8370.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II
(30-45mm) with 5.4 % of modified bitumen binder consisting of 4.97% VG-
30 bitumen (60/70 grade) 0.43% Plastomeric Thermoplastics (Waste plastic
Additive).

21.78.11 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 7933.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I
(50-65mm) with 5.2 % of modified bitumen binder consisting of 4.78% VG-
30 bitumen (60/70 grade) 0.42% Plastomeric Thermoplastics (Waste plastic
Additive).

21.78.12 Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler,
transporting the hot mix to work site, laying with a paver finisher to the
required grade, level and alignment, rolling with smooth wheeled, vibratory
and tandem rollers to achieve the desired compaction as per MORTH
specification clause No. 508 complete in all respects complete as per cum 8521.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-
II (30-45mm) with 5.4 % of modified bitumen binder consisting of 4.97%
VG- 30 bitumen (60/70 grade) 0.43% Plastomeric Thermoplastics (Waste
plastic Additive).

21.79.1 Stone Matrix Asphalt (SMA) as per section 515 of MORTH 5th Revision:
Providing and laying stone Matrix Asphalt (SMA) using crushed aggregates
of specified grading (as per section 515 of MORTH 5th Revision): premixed
with modified bituminous binder containing Pelletized Cellous fibre at 0.3%
(on loose fibre basis) on the weight of total mix in the batch and
filler(Hydrated lime dust @ 2% of weight of aggregates, transporting the hot
mix to work site, Laying with a paver finisher to the required grade, level
and alignment, rolling with smooth wheeled, Vibratory and tandem rollers cum 10298.00
to achieve the desired compaction as per MORTH specifications clause no.
515 complete in all respects complete as per specification.- using 40-60
TPH capacity HMP with mechanical Paver, SMA - 45mm to 75mm
compacted thickness with 5.80% VG- 30 bitumen as per MORTH 5 revision
clause 515.

Page 135 of 375


21.79.2 Stone Matrix Asphalt (SMA) as per section 515 of MORTH 5th Revision:
Providing and laying stone Matrix Asphalt (SMA) using crushed aggregates
of specified grading (as per section 515 of MORTH 5th Revision): premixed
with modified bituminous binder containing Pelletized Cellous fibre at 0.3%
(on loose fibre basis) on the weight of total mix in the batch and
filler(Hydrated lime dust @ 2% of weight of aggregates, transporting the hot
mix to work site, Laying with a paver finisher to the required grade, level
and alignment, rolling with smooth wheeled, Vibratory and tandem rollers cum 10310.00
to achieve the desired compaction as per MORTH specifications clause no.
515 complete in all respects complete as per specification. - using 40-60
TPH capacity HMP with mechanical Paver, SMA - 40-50 mm compacted
thickness with 5.80% VG- 30 bitumen as per MORTH 5 revision clause 515.

Page No. 171


Note : KSRB 500-11, 13, 16,17,18,19
1 Labour for traffic control, which and ward and other miscellaneous duties
at site including sundries have been included in administrative overheads
of the contractor.
2 Where tack coat is required to be provided before laying mastic asphalt, the
same is required to be measured and paid separately
3 Where the contractors selected source of aggregates have poor affinity for
bitumen as a conditions for the approval of that source the bitumen shall
be treated with approved anti stripping agent as per the manufactures
recommendations without additional payment.
4 As per ministry circular No. RW/24011/01/2008-Mech. Dated
21.10.2011 , the use of Batch type Hot Mix Plant is Mandatory with effect
from 01.04.2012, where the cost of Bituminous work is greater than Rs.
25.00 crores.
Page No. 172

22.0 CONCRETE PAVEMENT


22.1 KSRRB M600-1. Construction of dry lean cement concrete mix CC1:5:10
with OPC cement @160Kgs, with 25mm and down size graded granite metal
coarse aggregate at 0.86cum and fine aggregates @ 0.58cum Sub- base over
a prepared sub-grade with (coarse and fine aggregate conforming to IS: 383)
aggregate cement ratio not to exceed 15:1. Aggregate gradation after
blending to be as per Table 600-1, cement content not to be less than 160
kg/ cum, optimum moisture content to be determined during trial length
construction, concrete strength not to be less than 10 Mpa at 7 days, mixed
in a batching plant, transported to site, laid with a paver with electronic
sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing
complete as per specifications.
. MORTH Specification No. 601

22.1.1 KSRRB M600-1. Construction of dry lean cement concrete mix CC1:5:10
with OPC cement @150Kgs, with 25mm and down size graded granite metal
coarse aggregate at 0.86cum and fine aggregates @ 0.58cum using Concrete
Batch mix Plant at 75 cum/hr capacity with slip form paver with electronic cum 3585.00
sensor.

22.1.2 KSRRB M600-1. Construction of dry lean cement concrete mix CC1:5:10
with OPC cement @150Kgs, with 25mm and down size graded granite metal
coarse aggregate at 0.86cum and fine aggregates @ 0.58cum using Concrete cum 3665.00
Batch mix Plant at 75 cum/hr capacity with fixed form paver.

22.1.3 KSRRB M600-1. Construction of dry lean cement concrete mix CC1:5:10
with OPC cement @120Kgs, and Fly ash 30 kg/cum confirming to IS:3812,
coarse aggregate at 0.86cum and fine aggregates @ 0.58cum using Concrete cum 3389.00
Batch mix Plant at 75 cum/hr capacity with slip form paver with electronic
sensor.
22.1.4 KSRRB M600-1. Construction of dry lean cement concrete mix CC1:5:10
with OPC cement @120Kgs, and Fly ash 30 kg/cum confirming to IS:3812,
coarse aggregate at 0.86cum and fine aggregates @ 0.58cum using Concrete cum 3159.00
Batch mix Plant at 75 cum/hr capacity with fixed form paver.

Page No : 174

Page 136 of 375


22.2.1 KSRRB M600-2. Providing and constructing un-reinforced, dowel jointed,
plain cement Pavement Quality concrete for pavements using Grade M-40
having Flexural strength not less than 4.50 Mpa over a prepared base with
OPC 420 kg/cum , coarse aggregate at 0.64cum, fine aggregates at
0.36cum, Coarse and fine aggregate confirming to IS:383-2016 and Table
600-3 of MORTH V Revision, with Superplastizer at 3lts conforming to IS
9103-2008. loading materials to batch mix plant by front end loader, mixed
in a cement concrete batch mix plant as per approved mix design,
transported to site in transit truck agitator 5cum capacity, laid with Paver,
compacted and finished in a continous operation as per IRC-15 including cum 5470.00
cost for providing of contraction, expansion, construction and longitudinal
joints, joint filler, seperation membrane of impermiable plastic sheet of 125
micron, groove cutting, sealant primer joint sealent, debonding strip, dowel
bars at 9 kg/cum, tie rods at 1.15 kg/cum, admixtures as approved, curing
compound, finishing to lines and grades, textured with texturing machine,
and curing including cost of all materials, labour, hire charges of
machineries, all lead &lift charges etc., complete as per specifications.Using
Concrete Batch mix Plant at 75cum/hr capacity with Slip form paver with
electronic sensor Clause 601 of MORTH
22.2.2 V Revision
KSRRB and IS Providing
M600-2. 456 Table-5
and constructing un-reinforced, dowel jointed,
plain cement Pavement Quality concrete for pavements using Grade M-40
having Flexural strength not less than 4.50 Mpa over a prepared base with
OPC 420 kg/cum , coarse aggregate at 0.64cum, fine aggregates at
0.36cum, Coarse and fine aggregate confirming to IS:383-2016 and Table
600-3 of MORTH V Revision, with Superplastizer at 3lts conforming to IS
9103-2008. loading materials to batch mix plant by front end loader, mixed
in a cement concrete batch mix plant as per approved mix design,
transported to site in transit truck agitator 5cum capacity, laid with Paver,
compacted and finished in a continous operation as per IRC-15 including cum 5518.00
cost for providing of contraction, expansion, construction and longitudinal
joints, joint filler, seperation membrane of impermiable plastic sheet of 125
micron, groove cutting, sealant primer joint sealent, debonding strip, dowel
bars at 9 kg/cum, tie rods at 1.15 kg/cum, admixtures as approved, curing
compound, finishing to lines and grades, textured with texturing machine,
and curing including cost of all materials, labour, hire charges of
machineries, all lead &lift charges etc., complete as per specifications.Using
Concrete Batch mix Plant at 75cum/hr capacity with fixed form paver

22.2.3 KSRRB M600-2. Providing and constructing un-reinforced, dowel jointed,


plain cement Pavement Quality concrete for pavements using Grade M-40
having Flexural strength not less than 4.50 Mpa over a prepared base with
OPC 370 kg/cum and GGBS 50 kg/cum confirming to IS:12089 coarse cum 5375.00
aggregate at 0.64cum, fine aggregates at 0.36cum.Using Concrete Batch
mix Plant at 75cum/hr capacity with Slip form paver with electronic sensor

22.2.4 KSRRB M600-2. Providing and constructing un-reinforced, dowel jointed,


plain cement Pavement Quality concrete for pavements using Grade M-40
having Flexural strength not less than 4.50 Mpa over a prepared base with
OPC 370 kg/cum and GGBS 50 kg/cum confirming to IS:12089 coarse cum 5421.00
aggregate at 0.64cum, fine aggregates at 0.36cum.Using Concrete Batch
mix Plant at 75cum/hr capacity with fixed form paver

22.2.5 KSRRB M600-2. Providing and constructing un-reinforced, dowel jointed,


plain cement Pavement Quality concrete for pavements using Grade M-40
having Flexural strength not less than 4.50 Mpa over a prepared base with
OPC 370 kg/cum and Fly ash 50 kg/cum confirming to IS:12089 coarse cum 5174.00
aggregate at 0.64cum, fine aggregates at 0.36cum.Using Concrete Batch
mix Plant at 75cum/hr capacity with Slip form paver with electronic sensor

22.2.6 KSRRB M600-2. Providing and constructing un-reinforced, dowel jointed,


plain cement Pavement Quality concrete for pavements using Grade M-40
having Flexural strength not less than 4.50 Mpa over a prepared base with
OPC 370 kg/cum and Fly ash 50 kg/cum confirming to IS:12089 coarse cum 5219.00
aggregate at 0.64cum, fine aggregates at 0.36cum.Using Concrete Batch
mix Plant at 75cum/hr capacity with fixed form paver

22.3 KSRRB M600-3. Construction of Rolled Cement Concrete mix 1:4:8 OPC
cement @180kgs, with 25mm and down size graded granite metal coarse
aggregate at 0.85cum and fine aggregates @0.57cum base course with
coarse and fine aggregate conforming to IS:383, aggregate cement ratio 12:1
and minimum cement content of 180kg/ cum, aggregate gradation to be as
per Table 600-4 after blending, mixing in batching plant at optimum cum 3402.00
moisture content, transporting to site, laying with a paver with electronic
sensor, compacting with 8-10 tonnes smooth wheeled vibratory roller to
achieve, the designed flexural strength, finishing and curing complete as
per specifications -

Page 137 of 375


Page No. 175
22.6.1 constructing un-reinforced, plain cement Pavements using Grade M-30 over
a prepared base with OPC 360 kg/cum coarse aggregate at 0.69cum, fine
aggregates at 0.46cum, Coarse and fine aggregate confirming to IS:383-
2016 with Superplastizer at 3lts conforming to IS 9103-2008. mixed in a
concrete mixer of not less than 0.6 cum capacity and appropriate weigh
batcher as per approved mix design, laid in approved fixed side form work
(steel channel, laying and fixing of 125 micronthick polythene film, wedges,
steel plates including levelling the form work as per drawing). & Spreading
the concrete with shovels, rackers compacted using needle, screed and
plate vibrator and finished with floaters in a continous operation including cum 4916.00
provision of contraction, expansion, construction and longitudinal joints,
including groove cutting charges, joint filler, separation membrane of
impermiable plastic sheet of 125 micron, sealant primer, joint sealant,
admixtures as approved, curing compound, finishing to lines and grades,
textured with texturing machine, and curing including cost of all materials,
labour, hire charges of machineries, all lead & lift charges etc., complete as
per specifications.

22.6.2 constructing un-reinforced, plain cement Pavements using Grade M-30 over
a prepared base with OPC 320 kg/cum and GGBS 40 kg/cum confirming
to IS:12089, coarse aggregate at 0.69cum, fine aggregates at 0.46cum,
Coarse and fine aggregate confirming to IS:383-2016 with Superplastizer at
3lts conforming to IS 9103-2008. mixed in a concrete mixer of not less than
0.6 cum capacity and appropriate weigh batcher as per approved mix
design, laid in approved fixed side form work (steel channel, laying and
fixing of 125 micronthick polythene film, wedges, steel plates including
levelling the form work as per drawing). & Spreading the concrete with
shovels, rackers compacted using needle, screed and plate vibrator and cum 4838.00
finished with floaters in a continous operation including provision of
contraction, expansion, construction and longitudinal joints, including
groove cutting charges, joint filler, separation membrane of impermiable
plastic sheet of 125 micron, sealant primer, joint sealant, admixtures as
approved, curing compound, finishing to lines and grades, textured with
texturing machine, and curing including cost of all materials, labour, hire
charges of machineries, all lead & lift charges etc., complete as per
specifications.

22.6.3 constructing un-reinforced, plain cement Pavements using Grade M-30 over
a prepared base with OPC 320 kg/cum and Fly ash 40 kg/cum confirming
to IS:3812, coarse aggregate at 0.69cum, fine aggregates at 0.46cum,
Coarse and fine aggregate confirming to IS:383-2016 with Superplastizer at
3lts conforming to IS 9103-2008. mixed in a concrete mixer of not less than
0.6 cum capacity and appropriate weigh batcher as per approved mix
design, laid in approved fixed side form work (steel channel, laying and
fixing of 125 micronthick polythene film, wedges, steel plates including
levelling the form work as per drawing). & Spreading the concrete with
shovels, rackers compacted using needle, screed and plate vibrator and cum 4679.00
finished with floaters in a continous operation including provision of
contraction, expansion, construction and longitudinal joints, including
groove cutting charges, joint filler, separation membrane of impermiable
plastic sheet of 125 micron, sealant primer, joint sealant, admixtures as
approved, curing compound, finishing to lines and grades, textured with
texturing machine, and curing including cost of all materials, labour, hire
charges of machineries, all lead & lift charges etc., complete as per
specifications.

22.7 Vaccum de-watering with vaccum pump and suction mat and compaction
with skin floater clubbed with floating disc including cost of generator,
HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., Sqm 68.00
with all lead and lift.
22.8.1 Providing groove cutting for width of 5mm to 10mm and depth 80mm-
100mm including cost of cutting machine, generator & HOM of machinery,
including cost of blade,coolant etc., including cleaning of groove & providing
sand and hot bitumen fillars, and filler metal etc., including cost of Rmt. 135.00
conveyance of all materials, labour, lead and lift charges and all other
incidental charges as per drawing and as per specifications. - for concrete
pavement

22.8.2 Providing groove cutting for width of 5mm to 10mm and depth 80mm-
100mm including cost of cutting machine, generator & HOM of machinery,
including cost of blade,coolant etc., including cleaning of groove & providing
sand and hot bitumen fillars, and filler metal etc., including cost of Rmt. 100.00
conveyance of all materials, labour, lead and lift charges and all other
incidental charges as per drawing and as per specifications. - for asphalt
pavement

Page 138 of 375


22.9 Providing and Laying M40 grade high early strngth concrete produced by
ISO-9001 accredited plants, confirming ti IS 10262-2009 with strength of
40Mpa attained at 72 hrs with OPC @ 430kgs/cum confirming to IS 269-
2015, aggregates 20mm @ 680 kgs/cum, 12.5mm @430 Kgs/cum & Fine
aggregates (M-sand/River sand) confirming to IS 383-2016 @ 710kgs/cum
and using Mineral admixture such as Ultrafine GGBS, Silica Fumes & Rice
Husk etc @50kgs/cum confirming to IS 456-200. Fine particles below 75
micron should confirm to IS 383-2016 for fine aggrgates. Water content cum 6774.00
max. 160 kgs/cum & slump to be between 150mm to 180mm with
retention of 1 hour at site inluding cost of all materials, labour charges,
scaffolding, curing & hire charges of machineries etc complete as per the
directions of engineer incharge of the work.

Note 1. The specification 22.9 shall be operated only after the approval of
uperintending Engineer. Necessary quality control tests certificate shall be
obtained
Note 2. The mineral admixtures shall confirm to particle size of d95 < 11 microns
and mean particle size of d50 not more than 6 microns when tested in PSD
analyser as per ISO 13322.
Page No. 176

23.0 23.GEOSYNTHETIC AND REINFORCED EARTH


23.1 KSRRB M700-1. Construction of sub surface drain 200 mm dia using
geotextilestreated with carbon black with physical properties as given in
clause 700.2.2.3 formed in to a stable network and a planar geocomposites
structure, joints wrapped with geotextiles to prevent ingress of soil, all as m 661.00
per clause 700.2 and approved drawings including excavation and
backfilling complete as per specifications.MORTH Specification No. 702

23.2 KSRRB M700-2. Construction of a narrow filter sub- surface drain Narrow
Filter Sub-Surface Drain consisting of porous or perforated pipe laid in
narrow trench surrounded by a geotextiles filter fabric, with a minimum of
450 mm overlap of fabric and installed as per clause 700.2.3 and 300.9.3.5 m 754.00
including excavation and backfilling complete as per specifications. MORTH
Specification No. 702.4

23.3 KSRRB M700-3. Laying Paving Fabric Beneath a Pavement Overlay:-


Providing and laying paving fabric with physical requirements as per Table
704-2 over a tack coat of paving grade Bitumen 80-100 penetration, laid at
the rate of 1 kg per sqm over thoroughly cleaned and repaired surface to
provide a water resistant membrane and crack retarding layer. Paving
fabric to be free of wrinkling and folding and to be laid before cooling of tack Sqm 73.00
coat, brooming and rolling of surface with pneumatic roller to maximise
paving fabric contact with pavement surface complete as per specifications.
MORTH Specification No. 703

23.4 KSRRB M700-4. Laying Boulder Apron in Crates of Synthetic Geogrids:-


Providing, preparing and l aying of geogrids crated apron 1 m x 5 m, 600
mm thick including excavation and backfilling with baffles at 1 metre
interval, made with geogrids having characteristics as per clause 700.4.2,
joining sides with connectors/ring staples, top corners to be tie tensioned,
placing of suitable cross interval ties in layers of 300 mm connecting
opposite side with lateral braces and tied with polymer braids to avoid
bulging, constructed as per clause 700.4.3. filled with stone with minimum cum 3760.00
size of 200 mm and specific gravity not less than 2.65, packed with stone
spalls, keyed to the foundation recess in case of sloping ground and laid
over a layer of geotextiles to prevent migration of fines, all as per clause
700.4 and laid as per clause 200.5.3.3 and approved design complete as
per specifications.MORTH Specification No. 704

Page No. 178

24.0 TRAFFIC SIGNS, MARKINGS & OTHER ROAD APPURTENANCES


24.1 KSRRB 800-1. Painting two coats after filling the surface with synthetic
enamel paint in approved shades on new plastered concrete surfaces, with
materials, labour complete as per specifications. MORTH Chapter 8 Sqm 80.00

Page 139 of 375


24.2.1 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Providing and fixing of
retro- reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over
aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post
75mm X 75mm X 6mm firmly fixed to the ground by means of properly No 3454.00
designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60
cm, 60 cm below ground level as per approved drawing- 900 MM
Equilateral triangle - TYPE XI

24.2.2 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Providing and fixing of


retro- reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over
aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post
75mm X 75mm X 6mm firmly fixed to the ground by means of properly No 2493.00
designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60
cm, 60 cm below ground level as per approved drawing- 600 MM
Equilateral triangle - TYPE XI

24.2.3 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Providing and fixing of


retro- reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over
aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post
75mm X 75mm X 6mm firmly fixed to the ground by means of properly No 3122.00
designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60
cm, 60 cm below ground level as per approved drawing- 600 MM Circle -
TYPE XI

24.2.4 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Providing and fixing of


retro- reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over
aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post
75mm X 75mm X 6mm firmly fixed to the ground by means of properly No 4097.00
designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60
cm, 60 cm below ground level as per approved drawing- 600 x 800 mm -
TYPE XI

24.2.5 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Providing and fixing of


retro- reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over
aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post
75mm X 75mm X 6mm firmly fixed to the ground by means of properly No 3058.00
designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60
cm, 60 cm below ground level as per approved drawing- 600 x 450 mm -
TYPE XI

24.2.6 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Providing and fixing of


retro- reflectorised cautionary, mandatory and informatory sign as per
IRC:67 made of high intensity grade sheeting vide Clause 801.3, fixed over
aluminium sheeting, 1.5mm thick supported on a mild steel angle iron post
75mm X 75mm X 6mm firmly fixed to the ground by means of properly No 5047.00
designed foundation with M 15 grade cement concrete 45 cm x 45 cm x 60
cm, 60 cm below ground level as per approved drawing- 900 MM Octagon
Stop Board - TYPE XI

24.3 KSRRB M800-3. Direction and Place Identification Signs upto 0.9 sqm
Size Board:-Providing and erecting direction and place identification retro-
reflectorised sign as per IRC:67 made of high intensity grade sheeting vide
Clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not
exceeding 0.9sqm supported on a mild steel single angle iron post 75x75x6 Sqm 6863.00
mm firmly fixed to the ground by means of properly designed foundation
with M 15 grade cement concrete 45x45x60 cm, 60cm below ground level
as per approved drawing

24.4 KSRRB M800-3. Direction and Place Identification Signs more than 0.9
sqm Size Board:-Providing and erecting direction and place identification
retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting
vide Clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not
exceeding 0.9sqm supported on a mild steel single angle iron post 75x75x6 Sqm 7130.00
mm, 2 Nos. firmly fixed to the ground by means of properly designed
foundation with M 15 grade cement concrete 45x45x60 cm, 60cm below
ground level as per approved drawing

Page 140 of 375


24.5 KSRRB M800-5.1. Over head Signs (Truss and Vertical Support):-
Manufacturing supply and installation of retro-reflective overhead Gantry
signboards made out of cube corner micro prismatic grade sheeting
confirming to Type XI standards of IRC:67:2012 fixed over 4mm thick
Aluminium Composite Panel sheet, Excluding the cost of Type XI retro-
reflective sheeting and 4mm Thick ACP sheet suitable back support
frame over a designed support system of aluminium alloy or galvanised Tonne 70647.00
steel trestles and trusses of section type as per structural design
reguirements and approved plans complete as per specifications. Vertical
and Lateral clearance of the Gantry shall be as per IRC 67 2012 and as per
Clause 800.2.2 and 800.2.3 and installed as per clause 800.2.7.

Page No. 180


24.6 KSRRB M800-5.2. Over head Signs:-Supply and installation of retro-
reflective overhead Gantry signboards made out of cube corner micro
prismatic grade sheeting confirming to Type XI standards of IRC:67:2012
specification & fixed over 4mm thick Aluminium Composite Panel sheet
having minimum 0.30mm thick aluminum skin on both sides, Excluding Sqm 9525.00
the cost of back support frame, vertical support and horizontal
support and foundation. as directed by the engineer incharge of the work.

24.7 KSRRB M800-6. Painting two coats on New Concrete Surface:-Painting


two coats after filling the surface with synthetic enamel paint in all shades
on new plastered concrete surfaces complete as per specifications. MORTH Sqm 82.00
Specification No. 803
24.8.1 KSRRB M800-7. Painting:-Providing and applying two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803 - Sqm 72.00
Painting on Steel Surface
24.8.2 KSRRB M800-7. Painting:-Providing and applying two coats of ready mix
paint of approved brand after through cleaning of surface to give an even
shade complete as per specifications. MORTH Specification No. 803 - Sqm 79.00
Painting on Wood Surface
24.9 KSRRBM800-9. Painting New Letter and Figures of any Shade with
synthetic enamel paint black or any other approved colour to give an even
shade complete as per specifications. (“i) Hindi ( Matras commas and the cm 1.00
like not to be measured and paid for half letter shall be counted as half) “
MORTH Specification No. 803
24.10 KSRRB M800-10. Painting new letter and figures of any shade with
synthetic enamel paint black or any other approved colour to give an even
shade complete as per specifications. (“ii) English and Roman - Hyphen and cm 0.70
the like not to be measured and paid for “ MORTH Specification No.801

24.11 KSRRB M800-11.1.Painting lines, dashes, arrows etc.,on Roads in two


coats on New Work:-Painting lines, dashes, arrows etc on roads in two
coats on new work with ready mixed road marking paint conforming to
IS:164 on bituminous surface, including cleaning the surface of all dirt, Sqm 146.00
dust and other foreign matter, demarcation at site and traffic control
complete as per specifications. i) Over 10 cm in width. MORTH Specification
No. 803

Page No. 181


24.12 KSRRB M800-11.2. Painting lines, dashes, arrows etc.,on Roads in two
coats on New Work:-Painting lines, dashes, arrows etc on roads in two
coats on new work with ready mixed road marking paint conforming to
IS:164 on bituminous surface, including cleaning the surface of all dirt, Sqm 125.00
dust and other foreign matter, demarcation at site and traffic control
complete as per specifications.ii) Upto 10 cm in width MORTH
Specification No. 803

24.13 KSRRB M800-12.1.Painting lines, dashes, arrows etc.,on Roads in two


coats on Old Work:-Painting lines, dashes, arrows etc on roads in two
coats on old work with ready mixed road marking paint conforming to IS:
164 on bituminous surface, including cleaning the surface of all dirt, dust Sqm 130.00
and other foreign matter, demarcation at site and traffic control complete as
per specifications. i) Over 10 cm in width MORTH Specification No. 803

24.14 KSRRB M800-12.2 -Painting lines, dashes, arrows etc.,on Roads in two
coats on Old Work:-Painting lines, dashes, arrows etc on roads in two
coats on old work with ready mixed road marking paint conforming to IS:
164 on bituminous surface, including cleaning the surface of all dirt, dust Sqm 111.00
and other foreign matter, demarcation at site and traffic control complete as
per specifications. ii) Upto 10 cm in width MORTH Specification No. 803

Page 141 of 375


24.15 KSRRB M800-13.Road Marking with Hot Applied Thermoplastic
Compound with Reflectrising Glass Beads on Bituminous
Surface/Concrete Surface:- Providing and laying of hot applied
thermoplastic compound 2.5 mm thick including reflectorising glass beads
at 250 gms per sqm area, thickness of 2.5 mm is exclusive of surface Sqm 429.00
applied glass beads as per IRC:35. The finished surface to be level, uniform
and free from streaks and holes complete as per specifications. MORTH
Specification No. 803

24.16 KSRRB 800- Kilometre stone KSRRB M800-14.1. Reinforced cement


concrete M-15 5th Grade kilometre stone of standard design as per
IRC:8-1980, fixing in position including painting and printing etc complete Nos 3413.00
as per specifications.including additional M-15 concrete pedestal of 0.2mt.
height above G.L. MORTH Specification No. 804
24.17 KSRRB M800-14.2. Reinforced cement concrete M-15 Grade kilometre
stone of standard design as per IRC:8-1980, fixing in position including
painting and printing etc complete as per specifications.including additional Nos 2126.00
M-15 concrete pedestal of 0.2mt. height above G.L. MORTH Specification
No. 804
24.18 KSRRB M800-14.3. Reinforced cement concrete M-15 Grade 200m stone
of standard design as per IRC:26-1980, fixing in position including painting
and printing etc complete as per specifications. including additional M-15 Nos 541.00
concrete pedestal of 0.2mt. height above G.L. MORTH Specification No. 804

24.19 KSRRB M800-15. Road Delineators:-Supply and installation of Vertical


delineators having wide angle cube corner micro prismatic non metallic
reflective sheeting confirming to Type XI of IRC:67:2012 with White and Red
Colour combination and having minimum of retro reflective exposed area of
125 Sq CM on top slots & 35 Sq CM on bottom slots and no edges shall be
exposed for tampering. This tubular delineator shall have a core and shell
construction, shell shall be made of tough, high impact resistant, injection-
molded, thermoplastic outer body & the inner core shall consist of powder
coated or painted Mild steel of minimum thickness 1.0mm. & core-shell
structure shall be of height not less than 800 mmabove the ground and Nos 1852.00
width not less than 80mm. The metalic core of the delineator shall extend
300mm beyond the shell length from bottom for installing in the ground.
The extended portion of the metallic core having suitable slots to be fixed in
M20 grade Cement Concrete of size 300x300x400 MM with suitable
anchoring rods for enhancing the grip, as per IRC:79 Specifications.

Page No. 182


24.20 KSRRB M800-16. Boundry Pillar:- Reinforced cement concrete M-15 grade
boundry pillars of standard design as per IRC:25-1967, fixed in position
including finishing and lettering but excluding painting complete as per Nos 473.00
specifications.MORTH Specification No. 806
24.21 KSRRB M800- Fencing/ Railing KSRRB M800-17. G.I. Barbed Wire
Fencing 1.2 Metre High-Providing and fixing 1.2 metres high GI barbed
wire fencing with 1.8 m angle iron posts 40 mm x 40 mm x 6 mm placed
every 3 metres center to center founded in M15 grade cement concrete, 0.6
metre below ground level, every 15th post, last but one end post and corner
post shall be strutted on both sides and end post on one side only and m 204.00
provided with 9 horizontal lines and 2 diagonals interwoven with horizontal
wires, fixed with GI staples, turn buckles etc complete as per clause 800.7
as per specifications. MORTH Specification No. 807

24.22 KSRRB M800-18. G.I. Barbed Wire Fencing 1.8 Metre High:- Providing
and fixing 1.8 metres high GI barbed wire fencing with 2.4 m angle iron
posts 50 mm x 50 mm x 6 mm placed every 3 metres center to center
founded in M-15 grade cement concrete, 0.6 metre below ground level,
every 15th post, last but one end post and corner post shall be strutted on m 339.00
both sides and end post on one side only and provided with 12 horizontal
lines and 2 diagonals interwoven with horizontal wires, fixed with GI
staples, turn buckles etc complete as per clause 800.7 as per specifications.
MORTH Specification No. 807

24.23 KSRRB M800-19. Fencing with Welded Steel Wire Fabric 75mm x
50mm:-Providing 1.20 metre high fencing with angle iron posts 50 mm x
50 mm x 6 mm at 3 metre center to center with 0.40 metre embedded in
M15 grade cement concrete, corner, end and every 10th post to be strutted,
provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x m 509.00
25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc.
complete in all respects as per specifications. MORTH Specification
No.Suggestive

Page 142 of 375


Page No. 183
24.24 KSRRB M800-20.Tubular Steel Railing on Medium Weight Steel
Channel (ISMC Series) 100 mm x 50mm:-Providing, fixing and erecting
50 mm dia steel pipe railing in 3 rows duly painted on medium weight steel
channels (ISMC series) 100 mm x 50 mm, 1.2 metres high above ground, 2 m 1426.00
m centre to centre, complete as per approved drawings as per
specifications. MORTH Specification No. 808

24.25 KSRRB M800-21.Tubular Steel Railing on Precast RCC Posts, 1.2m High
Above Ground Level:-Providing, fencing and erecting 50 mm dia painted
steel pipe railing in 3 rows on precast M-20 Grade RCC vertical posts1.8
metres high (1.2 m above GL) with 3 holes 50 mm dia for pipe, fixed 2 m 1209.00
metres centre to, complete as per approved drawing as per specifications.
MORTH Specification No. 808

24.26 KSRRB M800- Crash Barrier KSRRB M800-22.Reinforced Cement


Concrete Crash Barrier:- Provision of an Reinforced cement concrete crash
barrier at the edges of the road, approaches to bridge structures and
medians, constructed with M-20 grade concrete with HYSD reinforcement
conforming to IRC:21 and dowel bars 25 mm dia, 450 mm long at
expansion joints filled with pre-moulded asphalt filler board, keyed to the
structure on which it is built and installed as per design given in the m 3287.00
enclosure to MOST circular No. RW / NH - 33022/1/94-DO III dated 24
June 1994 as per dimensions in the approved drawing and at locations
directed by the Engineer, all as specified complete as per specifications.
MORTH Specification No. 809

24.27 KSRRB M800-23.1. Metal Beam Crash Barrier:-Providing and erecting a


“W” metal beam crash barrier comprising of 3 mm thick corrugated sheet
metal beam rail, 70 cm above road/ground level, fixed on ISMC series
channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 1.8 m
high, 1.1 m below ground/road level, all steel parts and fitments to be
galvanised by hot dip process, all fittings to conform to IS:1367 and
m 1959.00
IS:1364, metal beam rail to be fixed on the vertical post with a spacer of
channel section 150 x 75 x 5 mm, 330 mm long complete as per clause
800.10 complete as per specifications excluding cost of earth work
excavation and PCC for fixing. A. Type - A, “W” MORTH Specification No.
810

24.28 KSRRB M800-23.2. Metal Beam Crash Barrier:-Providing and erecting a


“Thrie” metal beam crash barrier comprising of 3 mm thick corrugated
sheet metal beam rail, 85 cm above road/ground level, fixed on ISMC series
channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, 2 m
high with 1.15 m below ground level, all steel parts and fitments to be
galvanised by hot dip process, all fittings to conform to IS:1367 and
IS:1364, metal beam rail to be fixed on the vertical post with a space of m 3044.00
channel section 150 x 75 x 5 mm, 546 mm long complete as per clause
800.10 complete as per specifications. Excluding cost of
earth work excavation & PCC for fixing.B. Type - B, “THRIE” MORTH
Specification No. 810

Page No. 184


24.29 KSRRB M800-24. Flexible Crash Barrier, Wire Rope Safety Barrier:-
Providing and erecting a wire rope safety barrier with vertical posts of
medium weight RS Joist (ISMB series) 100 mm x 75 mm (11.50 kg/m), 1.50
m long 0.85 m above ground and 0.65 m below ground level, split at the
bottom for better grip, embedded in M-15 Grade cement concrete 450 x 450
x 450 mm, 1.50 m center to center and with 4 horizontal steel wire rope 40
mm dia and anchored at terminal posts 15 m apart. Terminal post to be
embedded in M 15 grade cement concrete foundation 2400 x 450 x 900 mm
(depth), strengthened by a strut of RS joist 100 x 75 mm, 2 m long at 45º m 1745.00
inclination and a tie 100 x 8 mm, 1.50 m long at the bottom, all embedded
in foundation concrete as per approved design and drawing, rate excluding
excavation and cement concrete complete as per specifications Excluding
cost of earth work excavation &
PCC for fixing. MORTH Specification No. Suggestive

Page 143 of 375


24.30 KSRRB M800- Anti-Glare devices in Median KSRRB M800-26.2. Providing
and erecting an anti - glare screen with 25 mm dia vertical pipes
fabricated and framed in the form of panels of one metre length and 1.75
metre height fixed with circular vane 250 mm dia at top and rectangular
vane 600 x 300 mm at the middle, made out of steel sheet of 3 mm
thickness, end vertical pipes of the panel made larger for embedding in
foundation concrete, applying 2 coats of paint on all exposed surfaces, all Each 2362.00
as per approved design and drawings complete as per specifications. B.
Anti-glare screen with 25 mm steel pipe framework fixed with circular and
rectangular vanes Excluding cost of earth work excavation &
PCC for fixing. MORTH Specification No. Suggestive

24.31 KSRRB M800-26.3. Providing and erecting anti - glare screen with
rectangular vanes of size 750 x 500 mm made from MS sheet, 3 mm thick
and fixed on MS angle 50 x 50 x 6 mm at an angle of 45º to the direction of
flow of traffic, 1.5 m center to center, top edge of the screen 1.75 m above
ground level, vertical post firmly embedded in M-15 cement concrete
foundation 0.60 m below ground level, applying 2 coats of paint on exposed m 714.00
faces, all complete as per approved design and drawings complete as per
specifications.C. Anti-glare screen with rectangular vane MS sheet.
Excluding cost of earth work excavation &
PCC for fixing. MORTH Specification No. Suggestive

24.32 KSRRB M800 - Street lighting KSRRB M800-27. Providing and erecting
street light mounted on a steel circular hollow pole of standard
specifications for street lighting, 9 m high spaced 40 m apart, 1.8 m
overhang on both sides if fixed in the median and on one side if fixed on the
footpath, fitted with sodium vapour lamp and fixed firmly in concrete Each 10815.00
foundation complete as per specifications. Excluding cost of earth work
excavation & PCC for fixing. MORTH Specification No. Suggestive

Page No. 185


24.33 KSRRB M800-28. Lighting on Bridges :- Providing and fixing lighting on
bridges, mounted on steel hollow circular poles of standard specifications, 5
m high fixed on parapets with cement concrete, 20 m apart and fitted with Each 6990.00
sodium vapour lamp complete as per specifications

24.34 KSRRB M800- Cable Duct Across the road KSRRB M800-29.1. Providing
and laying of a reinforced cement concrete pipe duct, 300 mm dia, across
the road (new construction), extending from drain to drain in cuts and toe
of slope to toe of slope in fills, constructing head walls at both ends,
providing a minimum fill of granular material over top and sides of RCC
pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular
material free of rock pieces, outer to outer distance of pipe at least half dia
of pipe subject to minimum450 mm in case of double and triple row ducts, m 1727.00
joints to be made leak proof, invert level of duct to be above higher than
ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997
and approved drawings complete as per specifications. Case - I : Single
row for one utility service

24.35 KSRRB M800-29.2. Cable Duct Across the road KSRRB M800-29.1.
Providing and laying of a reinforced cement concrete pipe duct, 300 mm
dia, across the road (new construction), extending from drain to drain in
cuts and toe of slope to toe of slope in fills, constructing head walls at both
ends, providing a minimum fill of granular material over top and sides of
RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular
material free of rock pieces, outer to outer distance of pipe at least half dia
of pipe subject to minimum450 mm in case of double and triple row ducts, m 3191.00
joints to be made leak proof, invert level of duct to be above higher than
ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997
and approved drawings complete as per specifications. Case - II : Double
row for two utility services

Page 144 of 375


24.36 KSRRB M800-29.3.Cable Duct Across the road KSRRB M800-29.1.
Providing and laying of a reinforced cement concrete pipe duct, 300 mm
dia, across the road (new construction), extending from drain to drain in
cuts and toe of slope to toe of slope in fills, constructing head walls at both
ends, providing a minimum fill of granular material over top and sides of
RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular
material free of rock pieces, outer to outer distance of pipe at least half dia
of pipe subject to minimum450 mm in case of double and triple row ducts, m 4681.00
joints to be made leak proof, invert level of duct to be above higher than
ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997
and approved drawings complete as per specifications. Case-III :Triple
row for three utility services.

24.37 KSRRB M800-Gantry mounted variable message sign board KSRRB M800-
33.1. Providing and erecting gantry mounted variable message sign board
electronically operated capable of flashing the desired message over a
designed support system of aluminium alloy or galvanised steel, erected as Tonne 67467.00
per approved design and drawings and with lateral clearance as per clause
800.2.3 complete as perspecifications. i) Gantry Support System

24.38 KSRRB M800-34Traffic input attenuators at abutments and piers KSRRB


M800-34.1. Providing and installation of traffic attenuators at
abutment/pier of flyovers bridges using scrap tyres of size 100 x 20
retrieved from trucks laid in 2 rows and 4 tiers, one above the other and Sqm 1343.00
tied with 20 mm wire rope as per approved design and drawings complete
as per specifications

24.39 KSRRB M800-34.2. Providing and installation of traffic impact attenuator at


abutment/pier of flyovers bridges using plastic/steel barrels 0.60 m dia and
1.0 m in height, filled with sand in three rows and tied with20 mm steel
wire rope as per approved design and drawings complete as per Sqm 1273.00
specifications. B. Using Plastic / steel Barrel, Filled with Sand

24.40 KSRRB M800-34.3. Providing and installing a patentend HI - DRO cell


system as a traffic impact attenuators, using plastic tubes 50 cm dia, 1.2 m
in height, 25 mm opening at the top, placed in three rows, filled with water
and tied with a 20 mm steel wire rope complete as per specifications. (In Sqm 762.00
this patented HI - DRO cell system, water gets discharged from plastic
tubes on impact over a pre-determined time, thus absorbing the energy) C.
With HI - DRO Cell Sandwich (Patented)

Page No. 186


24.41 KSRRB M800 Road markers / Road stud KSRRB M800-35. Providing and
fixing of road stud 100x 100 mm, diecast in aluminium, resistant to
corrosive effect of salt and grit, fitted with lense reflectors, installed in
concrete or asphaltic surface by drilling hole 30 mm upto a depth of 60 mm Nos 337.00
and bedded in a suitable bituminous grout or epoxy mortar, all as per BS:
873 part 4:1973 complete as per specifications

24.42 KSRRB M800- Traffic cone KSRRB M800-36. Provision of red fluorescent
with white reflective sleeve traffic cone made of low density polyethylene
(LDPE) material with a square base of 390 x 390 x 35 mm and a height of Nos 411.00
770 mm, 4 kg in weight, placed at 1.5 m interval, all as per BS: 873
complete as per specifications
24.43 KSRRB M800- policeman umbrella KSRRB M800-39. Provision of a 2 m
high (floor to roof) umbrella for traffic policeman at road crossings, where
necessary, installed on a raised platform, built on a central support of a
steel pipe 100 mm dia, roof made of 25 mm dia steel pipe to provide covered Nos 4591.00
area of 3 sqm, roofed with CGI sheets, all steel parts to be given 2 coats of
paint complete as per specifications

24.44 KSRRB M800-Portable barricade in construction zone KSRRB M800-43.


Installation of a steel portable barricade with horizontal rail 300 mm wide,
2.5 m in length fitted on a ‘A’ frame made with 45 x 45 x 5 mm angle iron
section, 1.5 m in height, horizontal rail painted (2 coats) with yellow and Each 2490.00
white stripes, 150 mm in width at an angle of 45º, ‘A’ frame painted with 2
coats of yellow paint, complete as per IRC:SP:55-2001 complete as per
specifications.

24.45 KSRRB M800-Permanent type barricade in construction zone KSRRB


M800-44.1. Construction of a permanent type barricade made of steel
components, 1.5 m high from road level, fitted with 3 horizontal rails 200
mm wide and 4 m long on 50 x 50 x 5 mm angle iron vertical support, Each 3829.00
painted with yellow and white strips, 150 mm in width at an angle of 45º,
complete as per IRC:SP:55-2001 complete as per specifications . A. With
steel components

Page No. 187

Page 145 of 375


24.46 KSRRB M800-44.2. Construction of a permanent type barricade made of
wooden components, 1.5 m high from road level, fitted with 3 horizontal
planks 200 mm wide and 3.66 m long on 100 x 100mm wooden vertical
post, painted with yellow and white strips, 150 mm in width at an angle of Each 7210.00
45º, complete as per IRC:SP:55-2001 complete as per specifications. B.
With Wooden components

24.47 KSRRB M800-44.3. Construction of a permanent type barricade made with


brick work in mud mortar, 1.5 m high, 4 m long, 600 mm thick, plastered
with cement mortar 1:6, painted with yellow and white strips complete as Each 16638.00
per specifications. C. With bricks
24.48 KSRRB M800-Drum delineator in construction zone KSRRB M800-45.
Provision of metal drum/empty bitumen drum delineator, 300 mm in
diameter, 800 mm high, filled with earth for stability, painted in
circumferential strips of alternate black and white 100 mm wide fitted with Each 524.00
reflectors 3 Nos of 7.5 cm dia, all as per IRC:SP:55- 2001 complete as per
specifications.

24.49 KSRRB M800-Flagman KSRRB M800-46. Positioning of a smart flagman


with a yellow vest and a yellow cap and a red flag 600 x 600 mm securely
fastened to a staff 1 m in length for guiding the traffic complete as per Each 549.00
specifications
24.51 Removing and verifying guard stones/KM stones/ boundary stones, in a
Each 51.00
complete manner embedded in earth excluding painting.
24.52 Providing and fixing RCC precast guard stones of size 0.23mx0.23mx1.5m
casted in cc 1:1.5:3 with 20mm down size aggregates using 10mm dia
vertical 4TMT steel rods and 8 mm dia stirrups at 20 cm c/c fixed 0.90 m
above Ground level using steel moulding, Curing, transportation to work
spot including excavation in hard soil fixing in plain cement concrete 1:2:4
using 20mm downsize aggregate including aligning to plumb and line
Each 2478.00
providing enamel painting to exposed faces in alternate black and white
strips and painting with reflective paint on top of guard stone with a width
of 10 cm including cost of all materials, labour, hire charge of machineries
complete. ( As per drawing)

24.53 Suppy & installation of Aluminium-backed flexible prismatic sheeting


made of Yellow coloured flexible prismatic sheeting with non-metallic
prismatic lens, formed in a transparent, syntheti resin, as retroreflective
elements mounted on a Aluminium (Al) foil with a pre-coated pressure
sensitive adhesive and easily removable liner containing screen printed
arrow/slant line pattern in black colour in a continous roll format and the Sqft 788.00
sheeting shall be extremely flexible and easy to bend or wrap around
objects, capable of exhibiting very high conformability and non-returning
dead-fold characteristics required for application on rough and uneven
surfaces.

24.54 Suppy & installation of flexible Median Markers made of combination of


tough, high impact resistant molded thermoplastic body with U shape
structure & rebound property & exposed body structure should be cornered
rounded for better aesthetics. The flexible median median marker shall
have U shaped florescent color retro-refleective sheeting with minimum
exposed reflective area 75 cm2. The reflective sheeting should confirm to
Type XI Florescent Yellow sheeting as per IRC 67 2012 . The third party test
report for reflective sheeting shall be submitted along with product
information. The product design has to with stand all natural impacts and No 353.00
should not get damaged if any pedastrian stamp on top of it intentionally or
unintentionally. The product should bend up to 90 degree on both sides
( becoming completely horizontal ), it should be able to take minimum 500
stamping without any significant damage. The flexible Median Marker shall
be fixed by a combination of epoxy adhesive and grouting/Drilling as
recommended by manufacturer

Page No. 188

Page 146 of 375


24.55 Supply & Installation of Solar Raised Pavement Markers made of
polycaarbonate molded body with circular shape, solar powered, LED self
illumination in active mode, 360 degree illumination and reflective panels
with micro prismatic lens in passive mode. The marker shall support a load
of 20000 kg tested in accordance to IRC 37 and shall be resistant to dust
and water ingress according to IP 65 ( Ingress Protection 65 is a test which
is conducted to check if solar road stud is protected from total dust Ingress
and low pressure water jets from any direction) standards and should
withstand temperatures in the range of 0 C to 70 C. Color of lighting could
be provided in red or yellow (amber) as per requirement and typical
frequency of blinking is 1 Hz. There should be current losses of less than 20
micron-amperes at 2.4 V in sleep-charging mode to enhance the life of the
marker and a full charge should provide for a minimum autonomy of the
marker of 50 hours. The height, width and length of the marker shall not be
less than 10 mm X 100 mm X 100 mm. Also, the surface diameter of the No 2961.00
marker shall not be less than 100 mm respectively. The weight of the
marker shall not be exceed 0.5 kilograms. Fixing will be by drilling holes on
the road for the shanks to go inside, without nails and using epoxy resin
based adhesive as per manufacturer's recommendation and complete as
directed by the engineer.

24.56 Supply & Installation of Rigid Median Marker made of tough, high impact
resistant, injection-molded, thermoplastic body with an isosceles
trapezoidal structure of length, width and height not less than 15cm, 10cm
and 10cm respectively and thickness not less than 1.8mm, the body
structure shall be rounded suitably. The plastic used for molding the
median marker shall conform to ASTM D256. The logo of yhe manufacturer
shall be embossed on either side of the body in the injection molding
process. The median marker shall have rectangular-shaped, flourescent
yellow colour retro-reflective sheeting of size not less than 8.5cm*8.5cm and No 445.00
with fully reflective micro prismatic cube corners as its retro-reflective
elements as per IRC 67 2012. The retro-reflective sheeting shall be a one or
both sides of the median marker and shall be edge protected with no
exposed edges which will prevent edge lifting, vandalism, sheeting damage,
etc. The median marker shall be fixed by a combination of epoxy adhesive
and grouting.

24.58 Manufacturing, supply and installation of Retro-reflective Hazard marker


signboards made out of cube corner micro prismatic grade sheeting
confirming to Type XI standards of IRC:67:2012 & ASTM D4956-09
specification & fixed over 4 mm thick Aluminium Composite Panel sheet
having minimum 0.30 mm thick aluminium skin on both sides & fixed over
back support frame of 25x25x3mm MS angle frame. Supported on the
round pipe post of 1.5 meters height and grouted 60cm Oxide paint and
two coats of synthatic enamel paint of black and firmly concrete foundation Sqm 4668.00
size of 45 cm x 45cm x 60cm including cost & conveyance of all materials,
equipment,machinery & labour with all leads and lifts, Loading charges
necessary for satisfactory completion of the work as directed by engineer
incharge.

Page No. 189

Page 147 of 375


24.59 Supplly and fixing of Retro Reflective Single Arrow Name Signboard of
size 1600mm x 900mm made out of retro reflective sheeting confirming to
Type XI standards of ASTM D 4956 - 09 & as per IRC 67-2012 for full back
ground of blue colour & white letters and fixed over 4 mm thick Aluminium
Composite Material sheet having minimum 0.5 mm thick Aluminium skin
on both sides with back side painted grey colour and fixed over back
support frame SS angle of 15mm x 20mm x 1.2mm, supported by 38mm
OD stainless steel pipe all round in 304 grade and 2 nos of vertical posts of
50mm OD stainless steel pipe of 202 grade firmly fixed to the ground by
means of propery designed fouundation of size 450mm x 450mm x 600mm Sqm 13297.00
in 1:1.5:3 ratio cement concrete. The background shall be blue in colour
with letters and border in white, the item includes earthwork excavation,
cost of all materials, loading, unloading, lead, lift, transportation etc.,
complete. as per direction of engineer incharge of work clause 6.9 of IRC 67
- 2012 for Type XI retro reflective sheeting from the sheeting manufacturer
& a certified copy of test reports from an independent test laboratory
confirming to clause 6.7 of IRC 67-2012 including outdoor weather
exposure report for the retro reflective sheeting offered shall be submitted
by the contractor for technical qualification in the tender.
24.60 Supplly and fixing of Retro Reflective Single Arrow Name Signboard of
size 2000mm x 900mm made out of retro reflective sheeting confirming to
Type XI standards of ASTM D 4956 - 09 & as per IRC 67-2012 for full back
ground of blue colour & white letters and fixed over 4 mm thick Aluminium
Composite Material sheet having minimum 0.5 mm thick Aluminium skin
on both sides with back side painted grey colour and fixed over back
support frame SS angle of 15mm x 20mm x 1.2mm, supported by 38mm
OD stainless steel pipe all round in 304 grade and 2 nos of vertical posts of
50mm OD stainless steel pipe of 202 grade firmly fixed to the ground by
means of propery designed fouundation of size 450mm x 450mm x 600mm Sqm 15785.00
in 1:1.5:3 ratio cement concrete. The background shall be blue in colour
with letters and border in white, the item includes earthwork excavation,
cost of all materials, loading, unloading, lead, lift, transportation etc.,
complete. as per direction of engineer incharge of work clause 6.9 of IRC 67
- 2012 for Type XI retro reflective sheeting from the sheeting manufacturer
& a certified copy of test reports from an independent test laboratory
confirming to clause 6.7 of IRC 67-2012 including outdoor weather
exposure report for the retro reflective sheeting offered shall be submitted
by the contractor for technical qualification in the tender.

Page No. 190


1 Lettering and arrow marks on sign board to be provided separately as per
actual requirement. Rates for these items have been analysed separately

2 Rate for excavation, cement concrete M-15 and painting may be taken from
respective chaters
3 Excavation and backfilling are incidental to work and not to be measured
separetely
4 In the case of median crash barrier, "W" metal beam or their beam section
should be provided on both sides of the vertical posts fixed in the median.
Extra provision for metal beam railing and spacer is required to be made
when fixed in the median depending on approved design.

5 Plantation of shrubs and plants of approved species in the median apart


from cutting off glare from vehicle coming from opposite directions, these
plants provide a pleasant environement and are eco-friendly

Page No. 191

25.BRIDGES - PILE FOUNDATION

25.1.1 KSRRB 1100- Bored / Cast-in-situ R.C.C. piles KSRRB 1100-1. Bored /
Cast-in-situ R.C.C. 1000mm dia. piles with OPC cement design mix
M20 @ 320kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 excluding reinforcement m 22620.00
as per drawings including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH /Chapter 12

25.1.2 KSRRB 1100- Bored / Cast-in-situ R.C.C. piles KSRRB 1100-1. Bored /
Cast-in-situ R.C.C. 1000mm dia. piles with OPC cement design mix
M30 @ 360kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 excluding reinforcement m 22798.00
as per drawings including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH /Chapter 12

Page 148 of 375


25.1.3 KSRRB 1100- Bored / Cast-in-situ R.C.C. piles KSRRB 1100-1. Bored /
Cast-in-situ R.C.C. 1000mm dia. piles with OPC cement design mix
M35 @ 390kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 excluding reinforcement m 22907.00
as per drawings including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH /Chapter 12

25.2.1 KSRRB 1100-2. Driving cast-in-place vertical R.C.C. 500mm dia. piles
with OPC cement design mix M20 @ 320kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregtes @
0.46cum, with superplastisiser @3lts confirming to IS9103- 1999 m 7963.00
Reaffirmed-2008 excluding reinforcement as per drawings including cost of
all materials, labour, HOM of machineries complete as per specifications.
MORTH / Chapter 12

25.2.2 KSRRB 1100-2. Driving cast-in-place vertical R.C.C. 500mm dia. piles
with OPC cement design mix M30 @ 360kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregtes @
0.46cum, with superplastisiser @3lts confirming to IS9103- 1999 m 7737.00
Reaffirmed-2008 excluding reinforcement as per drawings including cost of
all materials, labour, HOM of machineries complete as per specifications.
MORTH / Chapter 12

25.2.3 KSRRB 1100-2. Driving cast-in-place vertical R.C.C. 500mm dia. piles
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregtes @
0.46cum, with superplastisiser @3lts confirming to IS9103- 1999 m 7765.00
Reaffirmed-2008 excluding reinforcement as per drawings including cost of
all materials, labour, HOM of machineries complete as per specifications.
MORTH / Chapter 12

25.3 KSRRB M1100-3.1. Bored cast-in-situ R.C.C. Pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite metal
coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
excluding Reinforcement complete as per Drawing and Technical m 4632.00
Specifications and removal of excavated earth with all lifts and lead upto
1000 m complete as per specifications. A. Pile diametre =750
mm MORTH Specification No.1100 & 1700

25.4 KSRRB M1100-3.2. Bored cast-in-situ R.C.C. Pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite metal
coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
excluding Reinforcement complete as per Drawing and Technical m 7413.00
Specifications and removal of excavated earth with all lifts and lead upto
1000 m complete as per specifications. B. Pile diametre = 1000
mm MORTH Specification No.1100, 1600 & 1700

25.5 KSRRB M1100.3.3. Bored cast-in-situ R.C.C. Pile with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite metal
coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
excluding Reinforcement complete as per Drawing and Technical m 8300.00
Specifications and removal of excavated earth with all lifts and lead upto
1000 m complete as per specifications.- C. Pile diametre = 1200
mm MORTH Specification No.1100 & 1700

25.6 KSRRB M1100 Driven cast-in-place R.C.C. Pile KSRRB M1100-4.1. Driven
cast-in-place vertical R.C.C. Pile with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregtes @ 0.45cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008, excluding Reinforcement m 3713.00
complete as per Drawing and & Technical Specification complete as per
specifications. Pile diametre = 750 mm MORTH Specification No.1100 &
1700

Page No. 197


25.7 KSRRB M1100-4.2. Driven cast-in-place vertical R.C.C. Pile with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregtes @ 0.45cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 5987.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications. Pile diametre = 1000 mm
MORTH Specification No.1100 & 1700

Page 149 of 375


25.8 KSRRB M1100-4.3. Driven cast-in-place vertical R.C.C. Pile with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregtes @ 0.45cum,
with uperplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 8745.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications. Pile diametre = 1200 mm
MORTH Specification No.1100 & 1700

25.9 KSRRB M1100-4.4. Driven precast vertical R.C.C. Piles with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregtes @ 0.45cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 1708.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications.Pile diametre = 500 mm
MORTH Specification No. 1100 & 1700

25.10 KSRRB M1100-4.5. Driven precast vertical R.C.C. Piles with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite metal
coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 2934.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications- Pile diametre = 750 mm
MORTH Specification No. 1100 & 1700

25.11 KSRRB M1100-4.6. Driven precast vertical R.C.C. Piles with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite metal
coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 4914.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications Pile diametre = 1000 mm
MORTH Specification No.1100 & 1700

25.12 KSRRB M1100-4.7. Driven precast vertical R.C.C. Piles with OPC cement
design mix M35 @ 390kgs, with 20mm and down size graded granite metal
coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 1149.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications. Size of pile = 300 mm x 300
mm MORTH Specification No.1100 & 1700

25.13 KSRRB M1100-4.8. Driven precast vertical R.C.C. Piles with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregtes @ 0.45cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 1920.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications. Size of pile = 500 mm x 500
mm MORTH Specification No.1100 & 1700

25.14 KSRRB M1100-4.9. Driven precast vertical R.C.C. Piles with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregtes @ 0.45cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, m 3712.00
excluding Reinforcement complete as per Drawing and & Technical
Specification complete as per specifications. Size of pile = 750 mm x 750
mm MORTH Specification No.1100 & 1700

25.15 KSRRB M1100-5. Driven Vertical Steel Piles as per Drawing and &
Technical Specification complete as per specifications. Section of the pile
=H Section steel column 400 x 250 mm (ISHB Series) MORTH m 5089.00
Specification No.1100 & 1900
25.16 KSRRB M1100-6. Driven Vertical Steel Piles as per Drawing and &
Technical Specification complete as per specifications. Section of the pile
=H Section steel column 450 x 250 mm (ISHB Series) MORTH Specification m 5746.00
No.1100 & 1900
25.18 KSRRB M1100- Pile Cap KSRRB M1100-8.1. Cement Concrete for
Reinforced Concrete in Pile Cap as per Drawing and Technical Specification
complete as per specifications. A. RCC with OPC cement design mix M20 @
320kgs, with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts cum 5397.00
confirming to IS9103-1999 Reaffirmed-2008 Case-I: Using Concrete Mixer
MORTH Specification No.1100, 1500 & 1700

Page No. 198

Page 150 of 375


25.19 KSRRB M1100-8.2. Pile Cap KSRRB M1100-8.1. Cement Concrete for
Reinforced Concrete in Pile Cap as per Drawing and Technical Specification
complete as per specifications A. RCC with OPC cement design mix M20 @
320kgs, with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts cum 4666.00
confirming to IS9103-1999 Reaffirmed-2008 Case-II: Using Batching Plant,
Transit Mixer and Concrete Pump MORTH Specification No.1100, 1500 &
1700

25.20 KSRRB M1100-9.1. Cement Concrete for Reinforced Concrete in Pile Cap as
per Drawing and Technical Specification complete as per specifications. B.
RCC with OPC cement design mix M25 @ 340kgs, with 20mm and down
size graded granite metal coarse aggregates @0.7cum and fine aggregtes @ cum 5552.00
0.47cum, with superplastisiser @3lts confirming to IS9103- 1999
Reaffirmed-2009. Case-I: Using Concrete Mixer MORTH Specification
No.1100, 1500 & 1700

25.21 KSRRB M1100-9.2. KSRRB M1100-9.1. Cement Concrete for Reinforced


Concrete in Pile Cap as per Drawing and Technical Specification complete
as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs,
with 20mm and down size graded granite metal coarse aggregates @0.7cum
and fine aggregtes @ 0.47cum, with superplastisiser @3lts confirming to cum 4965.00
IS9103-1999 Reaffirmed-2009. Case-II: Using Batching Plant, Transit Mixer
and Concrete Pump MORTH Specification No.1100, 1500 & 1700

25.22 KSRRB M1100-10.1. Cement Concrete for Reinforced Concrete in Pile Cap
per Drawing and Technical Specification complete as per specifications. C.
RCC with OPC cement design mix M30 @ 360kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ cum 5670.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008. Case-I: Using Concrete Mixer MORTH Specification
No.1100, 1500 & 1700

25.23 KSRRB M1100-10.2. KSRRB M1100-10.1. Cement Concrete for Reinforced


Concrete in Pile Cap per Drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs,
with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts cum 4985.00
confirming to IS9103-1999 Reaffirmed-2008. Case-II: Using Batching Plant,
Transit Mixer and Concrete Pump MORTH Specification No.1100, 1500 &
1700

Page No. 199


25.24 KSRRB M1100-11.1. Cement Concrete for Reinforced Concrete in Pile Cap
complete as per Drawing and Technical Specification complete as per
specifications.D. RCC with OPC cement design mix M35 @ 390kgs, with
20mm and down size graded granite metal coarse aggregates @0.68cum
and fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to cum 5826.00
IS9103-1999 Reaffirmed-2008. Case-I: Using Concrete Mixer MORTH
Specification No.1100, 1500 & 1700

25.25 KSRRB M1100-11.2. -Cement Concrete for Reinforced Concrete in


Pile Cap complete as per Drawing and Technical Specification complete as
per specifications. D. RCC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregtes @ 0.45cum, with superplastisiser @3lts cum 5231.00
confirming to IS9103-1999 Reaffirmed-2008. Case-II: Using Batching Plant,
Transit Mixer and Concrete Pump MORTH Specification No.1100, 1500 &
1700

25.26 KSRRB M1100-Levelling course for Pile Cap KSRRB M1100-12. Providing
and laying of PCC M 15 levelling course 100 mm thick below the pile cap
complete as per specifications MORTH Specification No.1100 & 1700 cum 4345.00

25.27.2 KSRRB M1100- Supplying, Fitting and Placing un-coated HYSD bar /MS
Bar KSRRB M1100-13. Supplying, Fitting and Placing un-coated TMT bar
Reinforcement in Foundation as per Drawing and Technical Specifications Tonne 68001.00
complete as per specifications MORTH Specification No.1600 - TMT bars
Fe 500
25.27.3 KSRRB M1100- Supplying, Fitting and Placing un-coated HYSD bar /MS
Bar KSRRB M1100-13. Supplying, Fitting and Placing un-coated TMT bar
Reinforcement in Foundation as per Drawing and Technical Specifications Tonne 68480.00
complete as per specifications MORTH Specification No.1600 - TMT bars Fe
550

Page 151 of 375


25.28 KSRRB M1100-14. Supplying, fitting and placing un-coated Mild steel
reinforcement in foundation as per drawing and technical specification
complete as per specifications MORTH Specification No.1600 Tonne 51703.00

25.29 Trail Bores : Drilling 80mm dia hole through all kinds of soil using casing
shoe bit vertical or inclined up to 10 degree to vertical, as directed includ-
ing cost of materials, machineries, labour, water charges, remaining,
collection of wash samples at suitable intervals, logging and leaving, m 1389.00
supplying honne wood core box, fixing casing pipes (excluding cost of
casing pipes etc., complete.

Page No. 200


25.30 Trail Bores : Drilling 76mm dia (NX) core hole in soft rock using diamond
core bit vertical or inclined up to 10 degree to vertical, as directed in-
cluding cost of materials, machineries, labour, water charges, collection of
core samples, logging and leaving, supplying honne wood core box m 2416.00
including cement grounding (excluding cost of cement for grouting) and re-
drilling in case of collapse of sides etc., complete.

25.31 Trail Bores : Drilling 76 mm dia (NX) core hole in Hard rock using dia-
mond core bit vertical or inclined up to 10 degree to vertical as directed
including cost of materials, machineries, labour, including cement grouting m 4416.00
(excluding cost of cement for grouting) and re-drilling incase of collapse of
sides etc., complete.
Note : KSRRB 1100.1, KSRRB 1100.2
Note 1 : Rate for 450mm dia, 550mm dia, 750mm dia, piles and 1200 mm,.
Dia . Piles can be extrapolated as per proportionof pile cross-sectional area.

Note 2 : Item No.25.1 is to be adopted :


a) Only where manual labour is used for removal of excavated earth,
disposal of excavated earth etc., and when only pilling rig and Betonite
pump machinery is used.
Note 3 : Items No. 25.2, 25.2.1, 25.2.2, 25,3, 25,4, 25,5, 25,6, 25,7, 25.8,
25.9, 25.10, 25.11, 25.12, 25.13 & 25,14 are to be adopted where entire
work is taken up using machinery
Page No. 201

26.0 26.BRIDGES - WELL FOUNDATION


26.1 KSRRB M1200- Temporary Island KSRRB M1200-1.1. Providing and
Constructing Temporary Island 16 m diameter for Construction of Well
Foundation for 8m dia Well complete as per specifications. MORTH No 114966.00
Specification No. 1200
26.2 KSRRB M1200-1.2. Providing and Constructing Temporary Island 16 m
diameter for Construction of Well Foundation for 8m dia Well complete as
per specifications. B. Assuming depth of water 4.0 m and height of island No 701981.00
4.5m MORTH Specification No. 1200
26.3 KSRRB M1200-1.3. Providing and Constructing Temporary Island 16 m
diameter for Construction of Well Foundation for 8m dia Well complete as
per specifications. C. Providing and constructing one span service road to
reach island location from one pier location to another pier location- m 4595.00
Assuming span length 30 m, width of service road 10 m & depth of water 1
mMORTH Specification No. 1200

26.4 KSRRB M1200- Providing and Laying Cutting Edge of Mild Steel KSRRB
M1200-2. Providing and Laying Cutting Edge of Mild Steel weighing 40 kg
per metre for Well Foundation complete as per Drawing and Technical Tonne 76975.00
Specification complete as per specifications MORTH Specification No.1200
& 1900
26.5 KSRRB M1200-3.1. Plain / Reinforced Cement Concrete, in Well
Foundation complete as per Drawing and Technical Specification. MORTH
Specification No. 1200,1500 & 1700 -
26.5.1 KSRRB M1200-3.1 i) RCC with OPC cement design mix M20 @ 320kgs,
with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 6223.00
confirming to IS9103-1999 Reaffirmed-2008
26.5.2 KSRRB M1200-3.2 ii) RCC with OPC cement design mix M25 @
340kgs, with 20mm and down size graded granite metal coarse aggregates
@0.7cum and fine aggregates @ 0.47cum, with superplastisiser @3lts cum 6416.00
confirming to IS9103-1999 Reaffirmed-2008
26.5.3 KSRRB M1200-3.3. iii) RCC with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @3lts cum 6717.00
confirming to IS9103-1999 Reaffirmed-2008
Page No. 203

Page 152 of 375


26.5.4 KSRRB M1200-4.1. i) PCC with OPC cement design mix M15 @ 240kgs,
with 40mm and down size graded granite metal coarse aggregates
@0.63cum and fine aggregates @ 0.42cum, with superplastisiser @3lts cum 4908.00
confirming to IS9103-1999 Reaffirmed-2008
26.5.5 KSRRB M1200-4.2. ii) PCC with OPC cement design mix M20 @ 300kgs,
with 40mm and down size graded granite metal coarse aggregates
@0.64cum and fine aggregates @ 0.43cum, with superplastisiser @3lts cum 5435.00
confirming to IS9103-1999 Reaffirmed-2008
26.5.6 KSRRB M1200-4.3. iii) RCC with OPC cement design mix M20 @
320kgs, with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 5724.00
confirming to IS9103-1999 Reaffirmed-2008
26.5.7 KSRRB M1200-4.4. iv) PCC with OPC cement design mix M25 @ 340kgs,
with 40mm and down size graded granite metal coarse aggregates @0.7cum
and fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 5899.00
IS9103-1999 Reaffirmed-2008
26.5.8 KSRRB M1200-4.5. v) RCC with OPC cement design mix M25 @ 340kgs,
with 20mm and down size graded granite metal coarse aggregates @0.7cum
and fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 5900.00
IS9103-1999 Reaffirmed-2008
26.5.9 KSRRB M1200-4.6. vi) PCC with OPC cement design mix M30 @ 360kgs,
with 40mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 6003.00
confirming to IS9103-1999 Reaffirmed-2008
26.5.10 KSRRB M1200-4.7. vii) RCC with OPC cement design mix M30 @
360kgs, with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 6003.00
confirming to IS9103-1999 Reaffirmed-2008
26.5.11 KSRRB M1200-4.8 viii) RCC with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @3lts cum 6176.00
confirming to IS9103-1999 Reaffirmed-2008
Page No. 204
26.5.12 KSRRB M1200-4.9. ix) RCC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates
@0.67cum and fine aggregates @ 0.44cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008 - Using Batching Plant, Transit cum 5654.00
Mixer and Concrete PumpMORTH Specification No.1200,1500 & 1700

26.6 KSRRB M1200-5.1. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe. C. Bottom Plug: i) PCC with 43 grade
cement design mix M20 @ 320kgs, with 40mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 5320.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008.
Case - I : Using Concrete Mixer. MORTH Specification No.1200,1500 &
1700

26.7 KSRRB M1200-5.2. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe i) PCC with OPC cement design mix M20
@ 320kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser cum 4653.00
@3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II : Using
Batching Plant, Transit Mixer and Crane / Concrete PumpMORTH
Specification No.1200,1500 & 1700

26.8 KSRRB M1200-6.1. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe ii) PCC with OPC cement design mix M25
@ 340kgs, with 40mm and down size graded granite metal coarse
aggregates @0.7cum and fine aggregates @ 0.47cum, with superplastisiser cum 5763.00
@3lts confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using
Concrete MixerMORTH Specification No.1200,1500 & 1700

26.9 KSRRB M1200-6.2. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe ii)PCC with OPC cement design mix M25
@ 340kgs, with 40mm and down size graded granite metal coarse
aggregates @0.7cum and fine aggregates @ 0.47cum, with superplastisiser cum 4963.00
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer and Crane / Concrete Pump MORTH
Specification No.1200,1500 & 1700

Page No. 205

Page 153 of 375


26.10 KSRRB M1200-7.1. Plain / Reinforced Cement Concrete, in Well
Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe. iii) PCC with OPC cement design mix M30 @
360kgs, with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 6432.00
confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using Concrete
MixerMORTH Specification No.1200,1500 & 1700

26.11 KSRRB M1200-7.2. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe. :PCC with OPC cement design mix M30 @
360kgs, with 40mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 5060.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching
Plant, Transit Mixer and Crane / Concrete PumpMORTH Specification
No.1200,1500 & 1700

26.12 KSRRB M1200-8.1. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe. iv) PCC with OPC cement design mix M35 @
390kgs, with 40mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @3lts cum 6644.00
confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using Concrete
MixerMORTH Specification No.1200,1500 & 1700

26.13 KSRRB M1200-8.2. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification Concrete
to be placed using tremie pipe :PCC with OPC cement design mix M35 @
390kgs, with 40mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @3lts cum 5225.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching
Plant, Transit Mixer and Crane / Concrete PumpMORTH Specification
No.1200,1500 & 1700

26.14 KSRRB M1200-9.1. (i) PCC with OPC cement design mix M20 @ 320kgs,
with 40mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008 Same as in bottom plug cum 5210.00
concrete, excluding cost of forming sump, protective bunds, chiselling
etc.MORTH Specification No.1200,1500 & 1700

Page No. 206


26.15.1 D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well
Foundation MORTH Specification No.1200,1500 & 1700 - KSRRB M1200-
9.2. (ii) PCC with OPC cement design mix M25 @ 340kgs, with 40mm and
down size graded granite metal coarse aggregates @0.7cum and fine cum 5505.00
aggregates @ 0.47cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008

26.15.2 D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well


Foundation MORTH Specification No.1200,1500 & 1700 - KSRRB M1200-
9.3. (iii) PCC with OPC cement design mix M30 @ 360kgs, with 40mm and
down size graded granite metal coarse aggregates @0.69cum and fine cum 6432.00
aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008

26.16 E.Top Plug KSRRB M1200-10.1. (i) i) PCC design mix M15 with OPC cement
@ 240kgs, with 40mm and down size graded granite metal coarse
aggregates @0.63cum and fine aggregates @ 0.42cum MORTH Specification cum 4462.00
No.1200,1500 & 1700
26.17 KSRRB M1200-10.2. (ii) PCC with OPC cement design mix M20 @ 320kgs,
with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 5089.00
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification
No.1200,1500 & 1700
26.18 KSRRB M1200-10.3. (iii) PCC with OPC cement design mix M25 @ 340kgs,
with 40mm and down size graded granite metal coarse aggregates @0.7cum
and fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008 Same as item 2100-11.5. excluding cum 5384.00
formwork MORTH Specification No.1200,1500 & 1700

Page 154 of 375


26.19 KSRRB M1200-10.4. (iv) PCC with OPC cement design mix M30 @ 360kgs,
with 40mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008 Same as item 2100-11.9. cum 5478.00
excluding formwork MORTH Specification No.1200,1500 & 1700

Page No. 207


26.20 "KSRRB M1200-11.1. Plain / Reinforced Cement Concrete, in Well
Foundation complete as per Drawing and Technical Specification F. Well
cap. i) RCC with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine cum 6066.00
aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008.Case - I:Using Concrete Mixer” MORTH Specification
No.1200,1500 & 1700

26.21 "KSRRB M1200-11.2. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification. i) RCC
with OPC cement design mix M20 @ 320kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 cum 4751.00
Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer and
Crane / Concrete Pump”MORTH Specification No.1200,1500 & 1700

26.22 KSRRB M1200-11.3. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification. i) RCC
with OPC cement design mix M20 @ 320kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 5412.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008. Case - I : Using Concrete MixerMORTH Specification
No.1200,1500 & 1700

26.23 "KSRRB M1200-11.4. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification. (ii) RCC
with OPC cement design mix M25 @ 340kgs, with 20mm and down size
graded granite metal coarse aggregates @0.7cum and fine aggregates @
0.47cum, with superplastisiser @3lts confirming to IS9103-1999 cum 4920.00
Reaffirmed-2008. (Case - II : Using batching plant, transit mixer and
crane /Concrete ”MORTH Specification No.1200,1500 & 1700

26.24 "KSRRB M1200-11.5. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification. (iii) RCC
with OPC cement design mix M30 @ 360kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 5676.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008. Case - I : Using Concrete Mixer”MORTH Specification
No.1200,1500 & 1700

Page No. 208


26.25 "KSRRB M1200-11.6. Plain / Reinforced Cement Concrete, in Well
Foundation complete as per Drawing and Technical Specification. :RCC
with OPC cement design mix M30 @ 360kgs, with 20mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 cum 4993.00
Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer and
Crane / Concrete Pump”MORTH Specification No.1200,1500 & 1700

26.26 "KSRRB M1200-11.7. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification. (iv) RCC
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 5798.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008. Case - I : Using Concrete Mixer”MORTH Specification
No.1200,1500 & 1700

26.27 "KSRRB M1200-11.8. Plain / Reinforced Cement Concrete, in Well


Foundation complete as per Drawing and Technical Specification:RCC with
OPC cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 5155.00
Case - II : Using Batching Plant, Transit Mixer and Crane / Concrete
Pump”MORTH Specification No.1200,1500 & 1700

Page 155 of 375


26.28 "KSRRB M1200-12. Plain / Reinforced Cement Concrete, in Well
Foundation complete as per Drawing and Technical Specification (v) RCC
with OPC cement design mix M40 @ 420kgs, with 20mm and down size
graded granite metal coarse aggregates @0.67cum and fine aggregates @ cum 5292.00
0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008. Using Btching Plant, Transit Mixer and Concrete
Pump”MORTH Specification No.1200,1500 & 1700

26.29 KSRRB M1200- Sinking of well in sandy soil KSRRB M1200-13.1. Sinking
of 6 m external diameter well (other than pneumatic method of sinking)
through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications.
Depth of sinking is reckoned from bed level complete as per specifications. m 2436.00
(i) Depth below bed level upto 3.0 m. Rate of sinking = 0.50 m per hour
MORTH Specification No. Section 1200

Page No. 209


26.30 KSRRB M1200-13.2. Sinking of well in sandy soil KSRRB M1200-13.1.
Sinking of 6 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock
as shown against each case, complete as per drawing and technical m 3195.00
specifications. Depth of sinking is reckoned from bed level complete as per
specifications. ii) Beyond 3 m upto 10 m depth, Rate of sinking = 0.33 m
per hour MORTH Specification No. Section 1200

26.34 KSRRB M1200-14.1. Sinking of 7 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 3269.00
level complete as per specifications. A. Sandy Soil, Diameter of well = 7 m. i)
Depth below bed level upto 3.0 m, Rate of sinking = 0.30 m per hour.
MORTH Specification No. Section 1200

26.35 KSRRB M1200-14.2. Sinking of 7 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 4101.00
level complete as per specifications. A. Sandy Soil, Diameter of well = 7 m.
(ii) Beyond 3 m upto 10 m depth. Rate of sinking = 0.22 m per hour MORTH
Specification No. Section 1200

26.39 KSRRB M1200-15.1. Sinking of 8 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 3953.00
level complete as per specifications. (i) Depth below bed level upto 3.0 m.
Rate of sinking at 0.25 m per hour MORTH Specification No. Section 1200

26.40 KSRRB M1200-15.2.Sinking of 8 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 4736.00
level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate
of sinking at 0.20 m per hour MORTH Specification No. Section 1200

26.44 KSRRB M1200-16.1. Sinking of 9 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 4106.00
level complete as per specifications (i) Depth below bed level upto 3.0 m.
Rate of sinking at 0.25 m per hour MORTH Specification No. Section 1200

26.45 KSRRB M1200-16.2. Sinking of 9 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 5192.00
level complete as per specifications (ii) Beyond 3 m upto 10 m depth. Rate
of sinking = 0.18 m per hour MORTH Specification No. Section 1200

Page No. 210

Page 156 of 375


26.49.1 KSRRB M1200-17.1. Sinking of 10 m external diameter well ( other than
pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 4557.00
level complete as per specifications. MORTH Specification No. Section 1200
- i) Depth below bed level upto 3.0 m. Rate of sinking = 0.20 m / hour

26.49.2 KSRRB M1200-17.1. Sinking of 10 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 5586.00
level complete as per specifications. MORTH Specification No. Section 1200
- ii)Beyond 3 m upto 10 m depth. Rate of sinking = 0.17 m/ hour

26.53 KSRRB M1200-18.1. Sinking of 11 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 9488.00
level complete as per specifications. i) Depth below bed level upto 3.0 m,
Rate of sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.54 KSRRB M1200-18.2. Sinking of 11 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 10438.00
level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate
of sinking at 0.13 m per hour. MORTH Specification No. Section 1200

26.58 KSRRB M1200-19.1. Sinking of 12 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 21236.00
level complete as per specifications. i) Depth below bed level upto 3.0 m,
Rate of sinking at 0.05 m/ hour MORTH Specification No. Section 1200

26.59 KSRRB M1200-19.2. Sinking of 12 m external diameter well ( other than


pneumatic method of sinking ) through all types of strata namely sandy
soil, clayey soil and rock as shown against each case, complete as per
drawing and technical specifications. Depth of sinking is reckoned from bed m 25747.00
level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate
of sinking at 0.038 m/hour MORTH Specification No. Section 1200

26.63 KSRRB M1200-20.1. Sinking of Twin D Type well ( other than pneumatic
method of sinking ) through all types of strata namely, sandy soil, clayey
soil and rock as shown against each case, complete as per drawing and
technical specifications. Depth of sinking is reckoned from bed level m 4706.00
complete as per specifications. Overall length = 12 m, Overall width = 6 m.
(i) Depth from bed level upto 3.0 m, Rate of sinking at 0.18 m/ hour
MORTH Specification No. 1200

26.64 KSRRB M1200-20.2. Sinking of Twin D Type well ( other than pneumatic
method of sinking ) through all types of strata namely, sandy soil, clayey
soil and rock as shown against each case, complete as per drawing and
technical specifications. Depth of sinking is reckoned from bed level m 5178.00
complete as per specifications. Overall length = 12 m, Overall width = 6 m.
(ii) Beyond 3 m upto 10 m depth: Rate of sinking at 0.17 m/hour MORTH
Specification No. 1200

Page No. 211


26.68 KSRRB M1200-21.1. Sinking of 6 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 3194.00
complete as per specifications MORTH Specification No.Section 1200 (i)
Depth below bed level upto 3.00m, rate of sinking at 0.33m per hour

26.69 KSRRB M1200-21.2. Sinking of 6 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 7024.00
complete as per specifications MORTH Specification No.Section 1200 (ii)
Beyond 3 m upto 10 m depth. Rate of sinking = 0.17 m per hour MORTH
Specification No.Section 1200

Page 157 of 375


26.73 KSRRB M1200-22.1. Sinking of 7 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 4101.00
complete as per specifications. (i) Depth below bed level upto 3.0 m. Rate of
sinking = 0.22 m per hour MORTH Specification No. Section 1200

26.74 KSRRB M1200-22.2. Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 6497.00
complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate of
sinking = 0.17 m per hour MORTH Specification No. Section 1200

26.78 KSRRB M1200-23.1. Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 5013.00
complete as per specifications. (i) Depth from bed level upto 3.0 m. Rate of
sinking = 0.18 m/ hour MORTH Specification No. Section 1200

26.79 KSRRB M1200-23.2. Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 7200.00
complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate of
sinking = 0.17 m/ hour MORTH Specification No. Section 1200

26.83 KSRRB M1200-24.1. Sinking of 9 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 5394.00
complete as per specifications. (i) Depth below bed level upto 3.0 m. Rate of
sinking = 0.17 m per hour MORTH Specification No. Section 1200

26.84 KSRRB M1200-24.2. Sinking of 9 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 7732.00
complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate of
sinking = 0.15 m per hour MORTH Specification No. Section 1200

Page No. 212


26.88 KSRRB M1200-25.1. Sinking of 10 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 6651.00
complete as per specifications. (i) Depth below bed level upto 3.0 m, Rate of
sinking = 0.18 m/ hour MORTH Specification No. Section 1200

26.89 KSRRB M1200-25.2. Sinking of 10 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 8311.00
complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate of
sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.93 KSRRB M1200-26.1. Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 10956.00
complete as per specifications. i) Depth from bed level upto 3.0 m. Rate of
sinking = 0.10 m / hour MORTH Specification No. Section 1200

26.94 KSRRB M1200-26.2.Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 17696.00
complete as per specifications. (ii) Beyond 3 m upto 10 m depth. Rate of
sinking = 0.08 m/ hour MORTH Specification No. Section 1200

Page 158 of 375


26.98 KSRRB M1200-27.1. Sinking of 12 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 25857.00
complete as per specifications. i) Depth below bed level upto 3.0 m, Rate of
sinking = 0.04 m / hour MORTH Specification No. Section 1200

26.99 KSRRB M1200-27.2. Sinking of 12 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 39777.00
complete as per specifications. (ii) Beyond 3 m upto 10 m depth, Rate of
sinking = 0.03 m/ hour MORTH Specification No. Section 1200

26.103 KSRRB M1200-28.1. Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawing and
technical specifications. Depth of sinking is reckoned from bed level m 5850.00
complete as per specifications. i) Depth below bed level upto 3.0 m , Rate of
sinking = 0.16 m / hour MORTH Specification No. Section 1200

Page No. 213


26.104 KSRRB M1200-28.2.Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawing and
technical specifications. Depth of sinking is reckoned from bed level m 9136.00
complete as per specifications (ii) Beyond 3 m upto 10 m depth, Rate of
sinking = 0.15 m/ hour MORTH Specification No. Section 1200

26.107 KSRRB M1200.29. Sinking of 6 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 17357.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.25 m per hour MORTH Specification No. Section 1200

26.108 KSRRB M1200.30. Sinking of 7 m external diameter well (other than


pneumatic methodof sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 11977.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.22 m per hour MORTH Specification No. Section 1200

26.109 KSRRB M1200.31. Sinking of 8 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 13580.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.22 m per hour MORTH Specification No. Section 1200

26.110 KSRRB M1200.32. Sinking of 9m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 15538.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.111 KSRRB M1200.33. Sinking of 10m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 17186.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.14 m/ hour MORTH Specification No. Section 1200

Page No. 214


26.112 KSRRB M1200.34. Sinking of 11m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 38133.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.06 m / hour MORTH Specification No. Section 1200

Page 159 of 375


26.113 KSRRB M1200.35. Sinking of 12m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 82714.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.025 m / hour MORTH Specification No. Section 1200

26.114 KSRRB M1200.36. Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawing and
technical specifications. Depth of sinking is reckoned from bed level m 17896.00
complete as per specifications. Depth in soft rock strata upto 3 m. Rate of
sinking = 0.12 m / hour MORTH Specification No. Section 1200

26.115 KSRRB M1200- Hard Rock KSRRB M1200.37. Sinking of 6 m external


diameter well (other than pneumatic method of sinking) through all types of
strata namely sandy soil, clayey soil and rock as shown against each case,
complete as per drawing and technical specifications. Depth of sinking is m 15607.00
reckoned from bed level complete as per specifications. Depth in hard rock
strata upto 3 m. Rate of sinking = 0.17 m per hour MORTH Specification
No. Section 1200

26.116 KSRRB M1200.38. Sinking of 7 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 20182.00
complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.17 m per hour MORTH Specification No. Section 1200

Page No. 215


26.117 KSRRB M1200.39. Sinking of 8 m external diameter well (other than
pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 20913.00
complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.17 m per hour MORTH Specification No. Section 1200

26.118 KSRRB M1200.40. Sinking of 9 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 23662.00
complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.119 KSRRB M1200.41. Sinking of 10 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 24639.00
complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.12 m per hour MORTH Specification No. Section 1200

26.120 KSRRB M1200.42. Sinking of 11 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 53475.00
complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.05 m/hour MORTH Specification No. Section 1200

26.121 KSRRB M1200.43. Sinking of 12 m external diameter well (other than


pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level m 110329.00
complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.020 m/hour MORTH Specification No. Section 1200

26.122 KSRRB M1200.44. Sinking of Twin D Type Well (other than pneumatic
method of sinking) through all types of strata namely sandy soil, clayey soil
and rock as shown against each case, complete as per drawing and
technical specifications. Depth of sinking is reckoned from bed level m 26242.00
complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.10 m/hour MORTH Specification No. Section 1200

Page No. 216

Page 160 of 375


26.123 KSRRB M1200-45. Pneumatic sinking of wells with equipment of approved
design, drawing and specifications worked by competent and trained
personnel and comprising of compression and decompression chambers,
reducers, two air locks separately for men and plant & materials,
arrangement for supply of fresh air to working chambers, check valves,
exhaust valves, shafts made from steel plates of riveted construction not
less than 6 mm thick to withstand an air pressure of 0.50 MPa, controlled
blasting of hard rock where required, staircases and 1 m wide landing cum 57647.00
platforms with railing, arrangement for compression and decompression,
electric lighting of 50 V maximum, proper rooms for rest and medical
examinations and compliance with safety precautions as per IS:4138, all as
per clause 1200.7.6 of MORTH Specifications. MORTH Specification No.
Section 1200

26.124 KSRRB M1200-46. Sand filling in wells complete as per drawing and
cum 2648.00
technical specifications MORTH Specification No.1207
26.125 KSRRB M1200-47. Providing steel liner 10 mm thick for curbs and 6 mm
thick for seining of wells including fabricating and setting out as per
detailed drawing complete as per specifications MORTH Specification Tonne 68589.00
No.1200 & 1900
26.126 KSRRB M1200-Reinforced cement concrete for well curb KSRRB M1200-
48.1. Construction of cement concrete kerb with top and bottom width 115
and 165 mm respectively, 250 mm high in M-20 grade PCC on M-10 grade
foundation 150 mm thick, foundation having 50 mm projection beyond
kerb stone, kerb stone laid with kerb lying machine, founation concrete laid m 346.00
manually, all complete as per Clause 400.8 complete as per spcifications. A.
Using Concrete Mixer MORTH Specification No.408

26.127 KSRRB M1200-48.2. Construction of cement concrete kerb with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm
projection beyond kerb stone, kerb stone laid with kerb lying machine, m 276.00
foundation concrete laid manually, all complete as per Clause 400.8
complete as per spcifications. B. Using Concrete Batching and Mixing Plant
MORTH Specification No.408

26.128 KSRRB M1200-49.1. Cast-in-Situ Cement Concrete M 20 Kerb with


Channel. Construction of cement concrete kerb with channel with top and
bottom width 115 and 165 mm respectively, 250 mm high in M-20 grade
PCC on M-10 grade foundation 150 mm thick, kerb channel laid with kerb m 632.00
laying machine, foundation concrete laid manually, all complete as per
Clause 400.8 complete as per specifications. A. Using Concrete Mixer
MORTH Specification No.408

Page No. 217


26.129 KSRRB M1200-49.2. Cast-in-Situ Cement Concrete M 20 Kerb with
Channel. Construction of cement concrete kerb with channel with top and
bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade
PCC on M10 grade foundation 150 mm thick, kerb channel laid with kerb m 530.00
laying machine, foundation concrete laid manually, all complete as per
Clause 400.8 complete as per specifications. B. Using Concrete Batching
and Mixing Plant MORTH Specification No.408

26.130.1 Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in
50mm dia holes drilled in hard rock and grouting in CM 1:1 including
necessary bending, hooking, cutting and handling charges complete, Each 1691.00
including the cost of steel. (MORTH clause 1200). - below LWL in open
foundation upto 3m.
26.130.2 Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in
50mm dia holes drilled in hard rock and grouting in CM 1:1 including
necessary bending, hooking, cutting and handling charges complete, Each 1965.00
including the cost of steel. (MORTH clause 1200). - below LWL in open
foundation beyond 3m.
26.130.3 Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in
50mm dia holes drilled in hard rock and grouting in CM 1:1 including
necessary bending, hooking, cutting and handling charges complete, Each 3046.00
including the cost of steel. (MORTH clause 1200). - for well foundation
below LWL upto 3m.
26.130.4 Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in
50mm dia holes drilled in hard rock and grouting in CM 1:1 including
necessary bending, hooking, cutting and handling charges complete, Each 3882.00
including the cost of steel. (MORTH clause 1200). - for well foundation
below LWL beyond 3m.
1.KSRRB m 1200 13.3, 14,3, 15,3, 16,3, 17,3, 18,3, 19.3, 20,3, 21.3, 22.3,
23.3, 24.3, 25.3, 26.3, 27.3, and 28.3 beyond 10 m upto 20m

Page 161 of 375


2. KSRRB M 1200-13,4,14,.4, 15.3, 16.4, 18.4, 19.4, 20.3, 21.4, 22.4,
23.4, 24.4, 25.4, 26.4, and 28.4 beyond 20 m upto 30m,
a) add 7.5% for every additional meters of depth of sinking over the rate of
sinking for the pervious meter
b) add 20% of cost for Kentledge including supports, loading arrangement
and labour where cost is 80% of finished rate of previous meter

3. KSRRB M 1200-13.5, 14.5, 15,5, 16.,5, 17.5 18.5, 19.5, 20.5, 21.5,
22.5, 23.5, 24.5, 25.5, 26.5, 27.5. and 28.5 beyond 30 m upto 40m,
a) add 10% for every additional meters of depth of sinking over the rate of
sinking for the pervious meter
b) Add 20 % of cost for Kentledge including supports, loading arrangement
and labour where cost is 80% of finished rate of prevous meter

Page No. 218

27.0 27.BRIDGES - OPEN FOUNDATIONS


27.1 KSRRB M2100- Excavation in Ordinary Soil KSRRB M2100-1.1. Earth work
in excavation for foundation of structures as per drawing and technical
specifications, including setting out, construction of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and cum 195.00
bottom and backfilling with approved material complete as per
specifications I. Ordinary soil - A . Manual Means (i) Depth upto 3m
MORTH Specification No. 304

27.2 KSRRB M2100-1.2.Excavation in Ordinary Soil KSRRB M2100-1.1. Earth


work in excavation for foundation of structures as per drawing and
technical specifications, including setting out, construction of shoring and
bracing, removal of stumps and other deleterious matter, dressing of sides cum 251.00
and bottom and backfilling with approved material complete as per
specifications I. Ordinary soil - A . Manual Means .ii) 3 m to 6 m depth
MORTH Specification No. 304

27.3 KSRRB M2100-1.3.Excavation in Ordinary Soil KSRRB M2100-1.1. Earth


work in excavation for foundation of structures as per drawing and
technical specifications, including setting out, construction of shoring and
bracing, removal of stumps and other deleterious matter, dressing of sides cum 335.00
and bottom and backfilling with approved material complete as per
specifications I. Ordinary soil - A . Manual Means (iii ) Above 6 m depth
MORTH Specification No. 304

27.4 “KSRRB M2100-2.1. Earth work in excavation for foundation of structures


as perdrawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with cum 50.00
approved material complete as per specifications. B. Mechanical Means (i )
Depth upto 3 m” MORTH Specification No. 304

27.5 “KSRRB M2100-2.2.Earth work in excavation for foundation of structures


as perdrawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with cum 57.00
approved material complete as per specifications. B. Mechanical Means (ii )
Depth 3 m to 6 m” MORTH Specification No. 304

27.6 “KSRRB M2100-2.3.Earth work in excavation for foundation of structures


as perdrawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with
approved material complete as per specifications. B. Mechanical Means (i ) cum 73.00
Depth upto 3 m” MORTH Specification No. 304 B.Mechanical Means (iii )
Depth above 6 m MORTH Specification No. 304

27.7.1 KSRRB M2100-3.1. Earth work excavation in all kinds of ordinary rock /
soft rock not requiring blasting for foundation of bridges and allied works
as per drawing and technical specifications, including setting out, providing
shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and backfilling with approved material cum 279.00
including cost of all materials, labour, HOM complete as per specifications.
MORTH Specification No. 304 (i) 0m to 3m depth by manual means

27.7.2 KSRRB M2100-3.1. -do- (ii) 3m to 6m depth by manual means cum 332.00
27.7.3 KSRRB M2100-3.1. -do- (ii) Above 6m depth by manual means cum 413.00
27.7.4 KSRRB M2100-3.1. -do- (ii) 0m to 3m depth by Mechanical means cum 60.00
27.7.5 KSRRB M2100-3.1. -do- (ii) 3m to 6m depth by Mechanical means cum 69.00
27.7.6 KSRRB M2100-3.1. -do- (ii) Above 6m depth by Mechanical means cum 82.00

Page 162 of 375


27.9.1 KSRRB M2100-4.1. Earth work excavation in hard rock with blasting for
foundation of bridges and allied works as per drawing and technical
specifications, including setting out, providing of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and
bottom and backfilling with approved material including cost of all cum 586.00
materials, labour, HOM complete as per specifications. MORTH
Specification No. 304 (i) 0m to 3m depth by manual means

27.9.2 KSRRB M2100-4.1. -do- (ii) 3m to 6m depth by manual means cum 639.00
27.9.3 KSRRB M2100-4.1. -do- (ii) Above 6m depth by manual means cum 719.00
Page No. 220
27.10.1 KSRRB M2100-4.2. Earth work excavation in hard rock without blasting
for foundation of bridges and allied works as per drawing and technical
specifications, including setting out, providing of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and
bottom and backfilling with approved material including cost of all cum 471.00
materials, labour, HOM complete as per specifications. MORTH
Specification No. 304 (i) 0m to 3m depth by Mechanical means

27.10.2 KSRRB M2100-4.2. -do- (ii) 3m to 6m depth by Mechanical means cum 551.00
27.10.3 KSRRB M2100-4.2. -do- (ii) Above 6m depth by Mechanical means cum 631.00
27.11 KSRRB M2100 Excavation in Marshy soil KSRRB 2100-5. Excavation in
marshy soil upto 3m depth for foundations of structures as per drawing
and technical specifications including removing the excavated stuff to a
lead of 15m., including dewatering , shoring and shuttering, refilling cum 902.00
trenches in 250mm layers, wherever necessary watering and ramming,
including cost of all materials, labour complete as per specifications.
MORTH Chapter 12

27.12 KSRRB M2100-5.1. Earth work in excavation for foundation of structures


as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with cum 614.00
approved material complete as per specifications. “V. Marshy soil - A.
Manual Means Upto 3 m depth MORTH Specification No. 304

27.13 “KSRRB M2100-5.2. Earth work in excavation for foundation of structures


as per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with cum 145.00
approved material complete as per specifications. “V. Marshy soil - B.
Mechanical Means MORTH Specification No. 304

27.14 KSRRB M2100 Filling the foundations KSRRB 2100-6. Filling the
foundations trenches using approved sand as per drawing and technical
specifications in 250mm layers, wherever necessary watering and ramming, cum 3039.00
including cost of all materials, labour complete as per specifications.
MORTH Chapter 12
27.15 KSRRB M2100 Back Filling of abutments using wing wall & Returns
KSRRB M2100-7. Earth work in excavation for foundation of structures as
per drawing and technical specifications, including setting out,
construction of shoring and bracing, removal of stumps and other cum 349.00
deleterious matter, dressing of sides and bottom and backfilling with
approved material complete as per specifications. VI. Backfilling in Marshy
Foundation Pits.” MORTH Specification No. 304

27.16 KSRRB M2100-8. Filling Annular Space Around Footing in Rock Lean
cum 4908.00
cement concrete M 10 mix.
Page No. 221
27.18 KSRRB M2100 PCC 1 KSRRB M2100-10. Plain cement concrete M10 with
OPC cement @ 220kgs, with crushed 40mm and down size graded granite
metal coarse aggregates @0.84cum and fine aggregates @ 0.56cum, in
foundation mechanically mixed, placed in foundation and compacted by cum 5115.00
vibration including curing for 14 days complete as per specifications
MORTH Specification No. 2100

27.22 "KSRRB M2100-12.1. Stone Masonry Work in Cement Mortar 1:3 in


Foundation complete as per Drawing and Technical Specifications A.
Square Rubble Coursed Rubbie Masonry (first sort)”MORTH Specification cum 4354.00
No. 1405.4
27.23 KSRRB M2100-12.2. Stone Masonry Work in Cement Mortar 1:3 in
Foundation complete as per Drawing and Technical Specifications. B.
Random Rubble Masonry( coursed / uncoursed) MORTH Specification No. cum 4236.00
1405.4

Page 163 of 375


27.24 KSRRB M2100-13. Plain / Reinforced Cement Concrete M15 with OPC
cement @ 240kgs, with 40mm and down size graded granite metal coarse
aggregates @0.84cum and fine aggregates @ 0.56cum in Open Foundation cum 5103.00
complete as per Drawing and Technical Specifications MORTH Specification
No. 1500,1700 & 2100
27.25 "KSRRB M2100-14. Plain /Reinforcement Cement Concrete M20 with OPC
cement @ 300kgs, with 40mm and down size graded granite metal coarse
aggregates @0.64cum and fine aggregates @ 0.43cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008, in Open Foundation cum 5285.00
complete as per Drawing and Technical Specifications "MORTH
Specification No. 1500,1700 & 2100

27.27 "KSRRB M2100-15.2. Plain /Reinforcement Cement Concrete M20 with


OPC cement @ 320kgs, with 20mm and down size graded granite metal
coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, in Open cum 4857.00
Foundation complete as per Drawing and Technical Specifications Case -
II : With Batching Plant, Transit Mixer and Concrete Pump MORTH
Specification No. 1500,1700 & 2100

Page No. 222


27.29 KSRRB M2100-16.2. Plain / Reinforced Cement Concrete idesign mix M25
with OPC cement @ 340kgs, with 40mm and down size graded granite
metal coarse aggregates @0.70cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,Open cum 4995.00
Foundation complete as per Drawing and Technical Specifications Case - II
With Batching Plant, Transit Mixer and Concrete PumpMORTH
Specification No.1500,1700 & 2100

27.31 KSRRB M2100-17.2. Plain / Reinforced Cement Concrete idesign mix M25
with OPC cement @ 340kgs, with 20mm and down size graded granite
metal coarse aggregates @0.70cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,Open cum 4995.00
Foundation complete as per Drawing and Technical Specification Case - II :
With Batching Plant, Transit Mixer and Concrete Pump MORTH
Specification No. 1500,1700 & 2100

27.33 KSRRB M2100-18.2. Plain / Reinforced Cement Concrete in Open


Foundation with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine
aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103- cum 5084.00
1999 Reaffirmed-2008 complete as per Drawing and Technical
Specifications Case - II : With Batching Plant, Transit Mixer and Concrete
Pump MORTH Specification No. 1500,1700 & 2100

27.35 KSRRB M2100-19.2. Plain / Reinforced Cement Concrete in Open


Foundation with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine
aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103- cum 5084.00
1999 Reaffirmed-2008 complete as per Drawing and Technical
Specifications Case - II : With Batching Plant, Transit Mixer and Concrete
Pump MORTH Specification No. 1500,1700 & 2100

27.37 KSRRB M2100-20.2. Plain / Reinforced Cement Concrete in Open


Foundation with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103- cum 5222.00
1999 Reaffirmed-2008. case II : With Batching Plant, Transit Mixer and
Concrete Pump MORTH Specification No. 1500,1700 & 2100

Page No. 223


Note : 1. KSRRB M2100-1.1. KSRRB M2100-1,2, KSRRB M210-1,3, KSRRB
M2100-2,1, KSRRB M2100-2.2, KSRRB M2100-2.3, KSRRB M2100-3.1,
3.2, 4.1, 4.2. ADD 10% EXTRA for dewatering charges and specifications is
to be modified accordingly.
2 KSRRB M2100-5.1 ADD 30% Extra for dewatering charges and
specification is to be modified accordingly.
3 KSRRB M2100-5.2, Add 30% extra for dewatering charges and specification
is to be modified accordingly.
4 Add 15% extra for shoring and shuttering for items KSRRB M2 100-5,1
Specification is to be modified accordingly
5 Add 10% extra for shoring and shuttering for items KSRRB M2100-5.2,
Specifications is to be modified accordingly.
6 For excavation by manual means, add Rs. 5/m for every 'm' depth for 3m to
6m & Rs. 10/m for above 6m.
7 It is assumed that Marshy soil will be available upto 3 m depth only
Page No. 224

Page 164 of 375


28.0 28.BRIDGES - SUB-STRUCTURE
28.7.1 KSRRB M2200-5.1 M15 with OPC cement @ 240kgs, with 40mm and down
size graded granite metal coarse aggregates @0.63cum and fine aggregates cum 5421.00
@ 0.42cum upto 5mtr height
28.7.1.1 KSRRB M2200-5.1 M15 with OPC cement @ 240kgs, with 40mm and down
size graded granite metal coarse aggregates @0.63cum and fine aggregates cum 5963.00
@ 0.42cum above 5mtr height
28.7.2 KSRRB M2200-5.2. Design mix M20 with OPC cement @ 300kgs, with
40mm and down size graded granite metal coarse aggregates @0.64cum
and fine aggregates @ 0.43cum, with superplastisiser @3lts confirming to cum 5615.00
IS9103-1999 Reaffirmed-2008, upto 5 m height
28.7.2.1 KSRRB M2200-5.2. Design mix M20 with OPC cement @ 300kgs, with
40mm and down size graded granite metal coarse aggregates @0.64cum
and fine aggregates @ 0.43cum, with superplastisiser @3lts confirming to cum 6176.00
IS9103-1999 Reaffirmed-2008, above 5 m height
28.7.3 KSRRB M2200-5.3. Design mix M25 With OPC cement @ 340kgs, with
40mm and down size graded granite metal coarse aggregates @0.7cum and
fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 5321.00
IS9103-1999 Reaffirmed-2008 c) - i) Upto 5 m height
28.7.4 KSRRB M2200-5.4. Design mix M25 @ with OPC cement 340kgs, with
40mm and down size graded granite metal coarse aggregates @0.7cum and
fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 6012.00
IS9103-1999 Reaffirmed-2008 - ii) For height above 5 m and upto 10 m.

28.7.5 KSRRB M2200-5.5. Dsign mix M25 with OPC cement @ 340kgs, with
40mm and down size graded granite metal coarse aggregates @0.7cum and
fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 6358.00
IS9103-1999 Reaffirmed-2008 - iii) For height above 10 m.

Page No. 226


28.7.6 KSRRB M2200-5.6. design mix M30 with OPC cement @ 360kgs, with
40mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 5415.00
IS9103-1999 Reaffirmed-2008 - i) upto 5 m height
28.7.7 KSRRB M2200-5.7.Design mix M30 with OPC cement @ 360kgs, with
40mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 6118.00
IS9103-1999 Reaffirmed-2008 d) PCC Grade M-30 - ii) For height above 5 m
and upto 10 m.
28.7.8 KSRRB M2200-5.8. Design mix M30 with OPC cement @ 360kgs, with
40mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 6470.00
IS9103-1999 Reaffirmed-2008 - iii) For height above 10 m.

28.7.9 KSRRB M2200-5.9. Design mix M20 with OPC cement @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 5173.00
IS9103-1999 Reaffirmed-2008 - i) Upto 5 m height.
28.7.10 KSRRB M2200-5.10. Design mix M20 with OPC cement @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 5845.00
IS9103-1999 Reaffirmed-2008 - ii) For height, upto 10m
28.7.11 KSRRB M2200-5.11. Design mix M20 with OPC cement @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 6181.00
IS9103-1999 Reaffirmed-2008 - iii) For height above 10 m.

28.7.12 KSRRB M2200-5.12.Design mix M25 with OPC cement @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and
fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 5321.00
IS9103-1999 Reaffirmed-2008 - i) Upto 5m height
Page No. 227
28.7.13 KSRRB M2200-5.13. Design mix M25 with OPC cement @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and
fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 6012.00
IS9103-1999 Reaffirmed-2008 - ii)For height, upto 10m,
28.7.14 KSRRB M2200-5.14.Design mix M25 with OPC cement @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and
fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to cum 6358.00
IS9103-1999 Reaffirmed-2008 - iii) For height, above 10m,

Page 165 of 375


28.7.15 KSRRB M2200-5.15. design mix M30 with OPC cement @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 5415.00
IS9103-1999 Reaffirmed-2008 - i) Upto 5m height,
28.7.16 KSRRB M2200-5.16. Design mix M30 with OPC cement @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 6118.00
IS9103-1999 Reaffirmed-2008 g) RCC Grade M-30 - ii) For height, upto
10m,
28.7.17 KSRRB M2200-5.17. Design mix M30 with OPC cement @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum
and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 6470.00
IS9103-1999 Reaffirmed-2008 - iii) For height, above 10m,

28.7.18 KSRRB M2200-5.18.Design mix M35 with OPC cement @ 390kgs, with
20mm and down size graded granite metal coarse aggregates @0.68cum
and fine aggregates @ 0.45cum, with superplastisiser @3lts confirming to cum 5562.00
IS9103-1999 Reaffirmed-2008 - i) U pto 5m height,
28.7.19 KSRRB M2200-5.19. Design mix M35 with OPC cement @ 390kgs, with
20mm and down size graded granite metal coarse aggregates @0.68cum
and fine aggregates @ 0.45cum, with superplastisiser @3lts confirming to cum 6285.00
IS9103-1999 Reaffirmed-2008 - ii) For height, upto 10m,
Page No. 228
28.7.20 KSRRB M2200-5.20. Design mix M35 with OPC cement @ 390kgs, with
20mm and down size graded granite metal coarse aggregates @0.68cum
and fine aggregates @ 0.45cum, with superplastisiser @3lts confirming to cum 6646.00
IS9103-1999 Reaffirmed-2008 - iii) For height, above 10m,

28.8.2 KSRRB M2200- TMT/MS Bar Reinforcement KSRRB M2200-6. Supplying,


fitting and placing TMT bar reinforcement in sub-structure complete as per
drawing and Technical Specifications complete as per specificationsMORTH Tonne 68233.00
Specification No.1600 & 2200 - TMT Bars Fe 500

28.8.3 KSRRB M2200- TMT/MS Bar Reinforcement KSRRB M2200-6. Supplying,


fitting and placing TMT bar reinforcement in sub-structure complete as per
drawing and Technical Specifications complete as per specificationsMORTH Tonne 68812.00
Specification No.1600 & 2200 - TMT Bars Fe 550

28.10 KSRRB M2200- Providing Weep Holes KSRRB M2200-8. Providing weep
holes in Brick masonry / Plain / Reinforced concrete abutment, wing wall /
return wall with 100 mm dia AC pipe, extending through the full width of
the structure with slope of 1V :20H towards drawing foce. Complete as per Nos/mtr 147.00
drawing and Technical Specifications complete as per specifications
MORTH Specification No.2706 & 2200

28.11 KSRRB M2200-8.1. Back filling behind abutment, wing wall and return wall
complete as per drawing and Technical Specification complete as per
specifications. A. Granular material MORTH Specification No. 710.1.4 of cum 698.00
IRC:78 & 2200
28.13 KSRRB M2200- Filter Media KSRRB M2200-9. Providing and laying of Filter
media with granular materials/stone crushed aggregates satisfying the
requirements laid down in clause 2500.4.2.2. of MORTH specifications to a
thickness of not less than 600 mm with smaller size towards the soil and
bigger size towards the wall and provided over the entire surface behind cum 2091.00
abutment, wing wall and return wall to the full height compacted to a firm
condition complete as per drawing and Technical Specification complete as
per specifications MORTH Specification No. 710.1.4 of IRC:78 & 2200

28.14 KSRRB M2200- Bearings KSRRB M2200-10. Supplying, fitting and fixing in
position true to line and level cast steel rocker bearing conforming to IRC:
83(Pt.-1) section IX and clause 2000.3 of MORTH specifications complete Each Tonne
including all accessories as per drawing and Technical Specifications bearing 359.00
complete as per specifications MORTH Specification No.1000, 2000 & 2200 capacity

Page No. 229


28.15 KSRRB M2200-11. Supplying, fitting and fixing in position true to line and
level forged steel roller bearing conforming to IRC: 83(Pt.-1) section IX and
clause 2000.3 of MORTH specifications complete including all accessories
as per drawing and Technical Specifications complete as per specifications Tonne 20.00
MORTH Specification No.1000, 2000 & 2200

Page 166 of 375


28.16 KSRRB M2200-12. Supplying, fitting and fixing in position true to line and
level sliding plate bearing with PTFE surface sliding on stainless steel
complete including all accessories as per drawing and Technical
Specifications and BS: 5400, section 9.1 & 9.2 (for PTFE) and clause Tonne 1123.00
2000.4 of MORTH Specifications complete as per specifications MORTH
Specification No.2000 & 2200

28.17 KSRRB M2200-13. Supplying, fitting and fixing in position true to line and
level elastomeric bearing conforming to IRC: 83 (Part-II) section IX and
clause 2000.5 of MORTH specifications complete including all accessories C.C. 0.60
as per drawing and Technical Specifications complete as per specifications
MORTH Specification No. 2000 & 2200
28.18 KSRRB M2200-14. Supplying, fitting and fixing in position true to line and
level sliding plate bearing with stainless steel plate sliding on stainless steel
plate with mild steel matrix complete including all accessories as per Tonne 1121.00
drawing and Technical Specifications complete as per specifications
MORTH Specification No.2000 & 2200
28.19 KSRRB M2200-15. Supplying, fitting and fixing in position true to line and
level POT-PTFE bearing consisting of a metal piston supported by a disc or
unreinforced elastomer confined within a metal cylinder, sealing rings, dust
seals, PTFE surface sliding against stainless steel mating surface, complete
assembly to be of cast steel/fabricated structural steel, metal and elastomer
elements to be as per IRC: 83 part-I & II respectively and other parts Tonne 363.00
conforming to BS: 5400, section 9.1 & 9.2 and clause 2000.6 of MORTH
Specifications complete as per drawing and approved Technical
Specifications complete as per specifications MORTH Specification No.2000
& 2200

Note : 1.In case of stone masonry, the size of the weep hole shall be 150 mm x 80
mm or circular with 150mm diameter
2.For Structure in stone masonry, the weep holes shall be deemed to be
included in the item of stone masonry work and shall not be paid
separately
Page No. 230

29.0 29.BRIDGES - CONCRETE SUPERSTRUCTURE


29.1 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. A. RCC - with
OPC cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.1.1 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. A. RCC - with
OPC cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6223.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m

29.1.2 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. A. RCC - with
OPC cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6473.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.1.3 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. A. RCC - with
OPC cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6722.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

Page 167 of 375


29.1.4 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. A. RCC - with
OPC cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6677.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.1.5 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. A. RCC - with
OPC cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6884.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

29.2 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification - complete as per specifications. A. RCC with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.2.1 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification - complete as per specifications. A. RCC with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6473.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m

29.2.2 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification - complete as per specifications. A. RCC with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6722.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.2.3 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification - complete as per specifications. A. RCC with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6972.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.2.4 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification - complete as per specifications. A. RCC with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7314.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.2.5 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification - complete as per specifications. A. RCC with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7575.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008.
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

Page No. 232

Page 168 of 375


29.5 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. B. RCC with
OPC cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.5.1 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. B. RCC with
OPC cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 6418.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m -

29.5.2 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. B. RCC with
OPC cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 6676.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m -

29.5.3 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. B. RCC with
OPC cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 6934.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.5.4 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. B. RCC with
OPC cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 6896.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.5.5 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. B. RCC with
OPC cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7112.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

29.6 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. B. RCC with OPC
cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.6.1 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. B. RCC with OPC
cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 6676.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m

29.6.2 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. B. RCC with OPC
cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 6934.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

Page 169 of 375


29.6.3 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. B. RCC with OPC
cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7191.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.6.4 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. B. RCC with OPC
cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7542.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.6.5 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. B. RCC with OPC
cement design mix M25 @ 340kgs, with 20mm and down size graded
granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7811.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

29.9 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. C. RCC with
OPC cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.9.1 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. C. RCC with
OPC cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6574.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m

29.9.2 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. C. RCC with
OPC cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6838.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.9.3 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. C. RCC with
OPC cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7103.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.9.4 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. C. RCC with
OPC cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7448.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.9.5 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. C. RCC with
OPC cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7545.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

Page 170 of 375


Page No:233
29.10 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. C. RCC with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.10.1 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. C. RCC with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 6838.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m

29.10.2 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. C. RCC with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7103.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.10.3 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. C. RCC with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7367.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.10.4 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. C. RCC with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7723.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.10.5 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. C. RCC with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded
granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, cum 7999.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

29.13 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. D. RCC / PSC
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.68cum and fine aggregates @
0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH Specification No.
1500,1600 & 1700

29.13.1 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. D. RCC / PSC
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 6653.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m -

Page 171 of 375


29.13.2 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. D. RCC / PSC
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 6925.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.13.3 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. D. RCC / PSC
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 7197.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.13.4 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. D. RCC / PSC
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 7545.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.13.5 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. D. RCC / PSC
with OPC cement design mix M35 @ 390kgs, with 20mm and down size
graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 7829.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.14 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. D. RCC / PSC with
OPC cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

Page No. 234


29.14.1 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. D. RCC / PSC with
OPC cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, cum 6925.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m -

29.14.2 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. D. RCC / PSC with
OPC cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, cum 7197.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.14.3 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. D. RCC / PSC with
OPC cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, cum 7469.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

Page 172 of 375


29.14.4 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. D. RCC / PSC with
OPC cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, cum 7829.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.14.5 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. D. RCC / PSC with
OPC cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, cum 8113.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

29.15 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and
Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. D.
RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH
Specification No. 1500,1600 & 1700

29.15.1 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and
Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. D.
RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine cum 7741.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH
Specification No. 1500,1600 & 1700 - Height upto 5 m

29.15.2 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and
Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. D.
RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine cum 8285.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH
Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

29.15.3 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and
Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. D.
RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine cum 8830.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH
Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.15.4 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and
Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. D.
RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine cum 9531.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH
Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.15.5 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and
Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. D.
RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine cum 10099.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008, Case - I : Using Concrete Mixer MORTH
Specification No. 1500,1600 & 1700 - Height above 20 m

Page 173 of 375


29.19 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. E. PSC with
OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.19.1 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. E. PSC with
OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7434.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m -

29.19.2 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. E. PSC with
OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7506.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.19.3 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. E. PSC with
OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7760.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.19.4 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. E. PSC with
OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 8014.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.19.5 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing
and Technical Specification complete as per specifications. E. PSC with
OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 8269.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

Page No. 235


29.20 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. E. PSC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700

29.20.1 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. E. PSC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7072.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m -

Page 174 of 375


29.20.2 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. E. PSC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7309.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.20.3 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. E. PSC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7546.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.20.4 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. E. PSC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 8241.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.20.5 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. E. PSC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 8536.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008,
Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

29.22 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-10.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. RCC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700

29.22.1 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-10.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. RCC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 6269.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height upto 5 m

29.22.2 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-10.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. RCC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 6510.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

29.22.3 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-10.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. RCC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 6752.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

Page 175 of 375


29.22.4 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-10.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. RCC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7119.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.22.5 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-10.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. RCC with OPC
cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, cum 7377.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height above 20 m

Page No:236
29.23 Cast-in-situ box girder, segmental construction & balanced cantilever
KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. RCC with OPC cement design
mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700

29.23.1 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. RCC with OPC cement design
mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse cum 6993.00
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m

29.23.2 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. RCC with OPC cement design
mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse cum 7476.00
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m -

29.23.3 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. RCC with OPC cement design
mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse cum 7959.00
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.23.4 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. RCC with OPC cement design
mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse cum 8667.00
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

Page 176 of 375


29.23.5 Cast-in-situ box girder, segmental construction & balanced cantilever
KSRRB M2300-10.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. RCC with OPC cement design
mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse cum 9182.00
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.24 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing
and Placing Reinforced / Prestressed cement concrete in super-structure as
per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M40 @ 420kgs, with 20mm and down
size graded granite metal coarse aggregates @0.67cum and fine aggregates
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700

29.24.1 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing
and Placing Reinforced / Prestressed cement concrete in super-structure as
per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M40 @ 420kgs, with 20mm and down
size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 5931.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height upto
5m-

29.24.2 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing
and Placing Reinforced / Prestressed cement concrete in super-structure as
per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M40 @ 420kgs, with 20mm and down
size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 6172.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height 5 m
to 10 m

29.24.3 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing
and Placing Reinforced / Prestressed cement concrete in super-structure as
per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M40 @ 420kgs, with 20mm and down
size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 6414.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height 10
m to 15 m

29.24.4 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing
and Placing Reinforced / Prestressed cement concrete in super-structure as
per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M40 @ 420kgs, with 20mm and down
size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 6655.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height 15
m to 20 m

29.24.5 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing
and Placing Reinforced / Prestressed cement concrete in super-structure as
per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M40 @ 420kgs, with 20mm and down
size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 6896.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height
above 20 m

29.25 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-11.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum,
with superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008
MORTH Specification No. 1500,1600 & 1700

Page 177 of 375


29.25.1 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-11.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded cum 6387.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum,
with superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008
MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m

29.25.2 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-11.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded cum 6634.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum,
with superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008
MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

29.25.3 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-11.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded cum 6880.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum,
with superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008
MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.25.4 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-11.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded cum 7275.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum,
with superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008
MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.25.5 T - Beams & slabs including launching of precast girder by launching truss
upto 40m span KSRRB M2300-11.2. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and
Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded cum 7542.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum,
with superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008
MORTH Specification No. 1500,1600 & 1700 - Height above 20 m

Page No. 237


29.26 Cast-in-situ box girder, segmental construction & balanced cantilever
KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement
design mix M45 @ 440kgs, with 20mm and down size graded granite metal
coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH
Specification No. 1500,1600 & 1700

29.26.1 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement
design mix M45 @ 440kgs, with 20mm and down size graded granite metal cum 7128.00
coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH
Specification No. 1500,1600 & 1700 - Height upto 5 m

29.26.2 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement
design mix M45 @ 440kgs, with 20mm and down size graded granite metal cum 7622.00
coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH
Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

Page 178 of 375


29.26.3 Cast-in-situ box girder, segmental construction & balanced cantilever
KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement
design mix M45 @ 440kgs, with 20mm and down size graded granite metal cum 8116.00
coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH
Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.26.4 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement
design mix M45 @ 440kgs, with 20mm and down size graded granite metal cum 8880.00
coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH
Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.26.5 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-11.3. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement
design mix M45 @ 440kgs, with 20mm and down size graded granite metal cum 9414.00
coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH
Specification No. 1500,1600 & 1700 - Height above 20 m

29.27 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. G. PSC with OPC cement design mix M50 @
450kgs, with 20mm and down size graded granite metal coarse aggregates
@0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No.
1500,1600 & 1700

29.27.1 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. G. PSC with OPC cement design mix M50 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 7164.00
@0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m -

29.27.2 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. G. PSC with OPC cement design mix M50 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 7665.00
@0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.27.3 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. G. PSC with OPC cement design mix M50 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 8165.00
@0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.27.4 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. G. PSC with OPC cement design mix M50 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 8661.00
@0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

Page 179 of 375


29.27.5 Cast-in-situ box girder, segmental construction & balanced cantilever
KSRRB M2300-12. Furnishing and Placing Reinforced / Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. G. PSC with OPC cement design mix M50 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 8931.00
@0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.28 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-13. Furnishing and Placing Reinforced/ Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. H. PSC with OPC cement design mix M55 @
450kgs, with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No.
1500,1600 & 1700

29.28.1 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-13. Furnishing and Placing Reinforced/ Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. H. PSC with OPC cement design mix M55 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 7231.00
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m

29.28.2 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-13. Furnishing and Placing Reinforced/ Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. H. PSC with OPC cement design mix M55 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 7736.00
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.28.3 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-13. Furnishing and Placing Reinforced/ Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. H. PSC with OPC cement design mix M55 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 8242.00
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.28.4 Cast-in-situ box girder, segmental construction & balanced cantilever


KSRRB M2300-13. Furnishing and Placing Reinforced/ Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. H. PSC with OPC cement design mix M55 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 8739.00
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

Page No. 238


29.28.5 Cast-in-situ box girder, segmental construction & balanced cantilever
KSRRB M2300-13. Furnishing and Placing Reinforced/ Prestressed cement
concrete in super-structure as per drawing and Technical Specification
complete as per specifications. H. PSC with OPC cement design mix M55 @
450kgs, with 20mm and down size graded granite metal coarse aggregates cum 9012.00
@0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.29 KSRRB M2300 - TMT bar reinforcement KSRRB M2300-14. Supplying,


fitting and placing TMT bar reinforcement in super-structure complete as
per drawing and technical specifications complete as per specifications
MORTH Specification No. 1600
26.29.2 KSRRB M2300 - TMT bar reinforcement KSRRB M2300-14. Supplying,
fitting and placing TMT bar reinforcement in super-structure complete as
per drawing and technical specifications complete as per specifications Tonne 69804.00
MORTH Specification No. 1600 - TMT Bars Fe 415

Page 180 of 375


26.29.3 KSRRB M2300 - TMT bar reinforcement KSRRB M2300-14. Supplying,
fitting and placing TMT bar reinforcement in super-structure complete as
per drawing and technical specifications complete as per specifications Tonne 70250.00
MORTH Specification No. 1600 - TMT Bars Fe 415

29.30 KSRRB M2300 - High tensile wires KSRRB M2300-15. High tensile steel
wires / strands including all accessories for stressing, stressing operations
and grouting complete as per drawing and Technical Specifications Tonne 170260.00
complete as per specifications MORTH Specification No. 1800

Page No. 239

30.0 30.BRIDGES - RIVER TRAINING WORKS AND PROTECTION WORKS


30.1 KSRRB M2500-1.1. Providing and laying boulders apron on river bed for
protection against scour with stone boulders weighing not less than 40 kg
each complete as per drawing and Technical specification complete as per cum 1613.00
specifications. A. Boulder Laid Dry Without Wire Crates MORTH
Specification No. 2503
30.2 “KSRRB M2500-1.2. Providing and laying of boulder apron laid in wire
crates made with 4mm dia GI wire conforming to IS: 280 & IS:4826 in
100mm x 100mm mesh (weaved diagonally) including 10% extra for laps
and joints laid with stone boulders weighing not less than 40 kg each cum 2155.00
complete as per specifications. B. Boulder Apron Laid in Wire Crates”
MORTH Specification No. 2503

30.3 KSRRB M2500-Cement concrete blocks KSRRB M2500-2. Providing and


laying of apron with cement concrete blocks of size 0.5x0.5x0.5 m cast in-
situ and made with nominal mix of M- 15 grade cement concrete with a
minimum cement content of 240 kg / cum as per IRC: 21-2000 complete as cum 5420.00
per specifications MORTH Specification No. 2503

30.4 KSRRB M2500- Pitching KSRRB M2500-3. Providing and laying Filter
material underneath pitching in slopes complete as per drawing and cum 2342.00
Technical specification MORTH Specification No. 2504
30.5 KSRRB M2500-4.1. Providing and laying Pitching on slopes laid over
prepared filter media including boulder apron laid dry in front of toe of
embankment complete as per drawing and Technical specifications A. Stone cum 1613.00
/ Boulder MORTH Specification No. 2504
30.6 KSRRB M2500-4.2. Providing and laying Pitching on slopes laid over
prepared filter media including boulder apron laid dry in front of toe of
embankment complete as per drawing and Technical specifications cum 5420.00
complete as per specifications. B. Cement Concre
30.7 KSRRB M2500-Flooring with Rubble Stone KSRRB M2500-5.1. Providing
and laying Flooring complete as per drawing and Technical specifications
laid over cement concrete bedding complete as per specifications. A. Rubble cum 4526.00
stone laid in cement mortar 1:3 MORTH Specification No. 2505

30.8 “KSRRB M2500-5.2. Providing and laying Flooring complete as per drawing
and Technical specifications laid over cement concrete bedding complete as
per specifications. B. Cement Concrete Blocks Grade M-15" MORTH cum 6027.00
Specification No. 2505
Page No. 241
30.10 KSRRB M2500- Geotextile filter KSRRB M2500-7. Laying of a geotextile
filter between pitching and embankment slopes on which pitching is laid to
prevent escape of the embankment material through the voids of the stone
pitching / cement concrete blocks as well as to allow free movement of Sqm 118.00
water without creating any uplift head on the pitching complete as per
specifications MORTH Specification No. 700 & 2504

30.15 KSRRB M2500- Gabian Structure KSRRB M2500.12. Providing and


construction of a gabian structure for retaining earth with segments of wire
crates of size 7 m x 3 m x 0.6 m each divided into 1.5 m compartments by
cross netting, made from 4 mm galvanised steel wire at 32 kg per 10 sqm
having minimum tensile strength of 300 Mpa conforming to IS:280 and
galvanizing coating conforming to IS:4826, woven into mesh with double cum 3060.00
twist, mesh size not exceeding 100 x 100 mm, filled with boulders with
least dimension of 200 mm, all loose ends to be tied with 4 mm galvanised
steel wire complete as per specifications MORTH Specification No. 2503.3

Page 181 of 375


30.16 KSRRB M2500-13 Gabian Structure for Erosion Control, River Training
Works and Protection works Providing and constructing gabian structures
for erosion control, river training works and protection works with wire
crates of size 2 m x 1 m x 0.3 m each divided into 1m compartments by
cross netting, made from 4 mm galvanised steel wire @ 32 kg per 10 sqm
having minimum tensile strength of 300 Mpa conforming to IS:280 and
galvanizing coating conforming to IS:4826, woven into mesh with double cum 5254.00
twist, mesh size not exceeding 100 mm x 100 mm, filled with boulders with
least dimension of 200 mm, all loose ends to be securely tied with 4 mm
galvanised steel wire complete as per specifications MORTH Specification
No. 2503.3

Page No. 242

31.0 31.EXPANSION JOINTS


31.1 KSRRB M2600- Expansion Joints KSRRB M2600-1. Providing and laying a
burried expansion joint, expansion gap being 20 mm, covered with 12 mm
thick, 200 mm wide galvanised weldable structural steel plate as per IS:
2062, placed symmetrical to centre line of the joint, resting freely over the
top surface of the deck concrete, welding of 8 mm dia. 100 mm long m 1194.00
galvanised nails spaced 300 mm c/c along the centre line of the plate, all as
specified in clause 2600.4 MORTH Specification No. 2604

31.2 KSRRB M2600- Filler Joint KSRRB M2600-2. (i) Providing & fixing 2 mm
thick corrugated copper plate in expansion joint complete as per drawing &
Technical Specification complete as per specifications MORTH Specification m 2485.00
No. 2605
31.3 KSRRB M2600-3. (ii) Providing & fixing 20 mm thick compressible fibre
board in expansion joint complete as per drawing & Technical Specification
complete as per specifications MORTH Specification No. 2605 m 119.00

31.4 KSRRB M2600-4. (iii)Providing and fixing in position 20 mm thick


premoulded joint filler in expansion joint for fixed ends of simply supported
spans not exceeding 10 m to cater for a horizontal movement upto 20 mm, m 155.00
covered with sealant complete as per drawing & Technical Specification
MORTH Specification No. 2605
31.5 KSRRB M2600-5.(iv) Providing and filling joint sealing compound as per
drawings and technical specifications with coarse sand and 6 per cent
bitumen by weight complete as per specifications MORTH Specification No. m 33.00
2605
31.6 KSRRB M2600- Asphaltic Plug Joint KSRRB M2600-6. Providing and laying
of asphaltic plug joint to provide for horizontal movement of 25 mm and
vertical movement of 2 mm, depth of joint varying from 75 mm to 100 mm,
width varying from 500 mm to 750 mm (in traffic direction), covered with a
closure plate of 200mm x 6mm of weldable structural steel conforming to
IS: 2062, asphaltic plug to consist of polymer modified bitumen binder,
m 1079.00
carefully selected single size aggregate of 12.5 mm nominal size and a heat
resistant foam caulking/ backer rod, all as per approved drawings and
specifications, complete as per specifications MORTH Specification No.
2600

31.7 KSRRB M2600- Elastomeric Slab Seal Expansion Joint KSRRB M2600-7.
Providing and laying of an elastomeric slab steel expansion joint, catering to
right or skew (less than 20 deg., moderately curved with maximum
horizontal movement upto 50 mm, complete as per approved drawings and
standard specifications to be installed by the manufacturer/supplier or m 13951.00
their authorised representative ensuring compliance to the manufacturer’s
instructions for installation and clause 2600.6 of MORTH specifications for
road & bridge works complete as per specifications. MORTH Specification
No. 2606

Page No. 244


31.8 KSRRB M2600- Compression Seal Joint KSRRB M2600-8. Providing and
laying of compression seal joint consisting of steel armoured nosing at two
edges of the joint gap suitably anchored to the deck concrete and a
preformed chloroprene elastomer or closed cell foam joint sealer
compressed and fixed into the joint gap with special adhesive binder to m 16621.00
cater for a horizontal movement upto 40 mm and vertical movement of 3
mm complete as per specifications MORTH Specification No. 2600

Page 182 of 375


31.9 KSRRB M2600- Strip Seal Expansion Joint KSRRB M2600-9. Providing and
laying of a strip seal expansion joint catering to maximum horizontal
movement upto 70 mm, complete as per approved drawings and standard
specifications to be installed by the manufacturer/supplier or their m 13939.00
authorised representative ensuring compliance to the manufacturer’s
instructions for installation complete as per specifications MORTH
Specification No. 2607

31.10 KSRRB M2600- Modular Strip/ Box Seal Joint KSRRB M2600-10. Providing
and laying of a modular strip Box seal expansion joint including anchorage
catering to a horizontal movement beyond 70 mm and upto 140mm,
complete as per approved drawings and standard specifications to be
installed by the manufacturer/supplier or their authorised representative m 6234.00
ensuring compliance to the manufacturer’s instructions for installation
complete as per specifications MORTH Specification No. 2600

31.11 KSRRB M2600-11 Providing and laying of a modular strip box seal
expansion joint catering to a horizontal movement beyond 140mm and upto
210mm, complete as per approved drawings and standard specifications to
be installed by the manufacturer/supplier or their authorised m 7627.00
representative ensuring compliance to the manufacturer’s instructions for
installation. complete as per specifications. MORTH Specification No. 2600

Note :
1 Guidelines laid down vide the MORTH Circular no. RW/NH-34059/1/96-
S&R dated 30.11.2000 and subsequent corrigendum dated 25.01.2001 may
be referred for expansion joints.
2 The nominal size of aggregates shall be 12.5 mm for depth of joints upto
75 mm and 20 mm for joints of depth more than 75mm.
3 The installation shall be done by the manfufacturer or his authorised
representatives to the satisfaction of the Engineer.
4 The concrecting for joining the exapansion joint assembly with the deck has
not been included in this analysis as the same is catered in the quantities
of RCC deck
5 The anhcoring bars of the exapansion joint assembly shall be welded to the
main reinforcement of the deck
Page No. 245

32.00 32.BRIDGES - WEARING COAT & APPURTENANCES


32.1 KSRRB M2700- Mastic Asphalt KSRRB M2700-1. Providing and laying 12
mm thick mastic asphalt wearing course on top of deck slab excluding
prime coat with paving grade bitumen meeting the requirements given in
table 500-29, prepared by using mastic cooker and laid to required level
and slope after cleaning the surface, including providing antiskid surface
with bitumen precoated fine grained hard stone chipping of 9.5 mm
nominal size at the rate of 0.005cum per 10 sqm and at an approximate Sqm 316.00
spacing of 10 cm center to center in both directions, pressed into surface
when the temperature of surfaces not less than 100 deg. C, protruding 1
mm to 4 mm over mastic surface, all complete as per clause 5100.5
complete as per specifications. MORTH Specification No. 515 & 2702

32.2 KSRRB M2700- Railing KSRRB M2700-2. Construction of precast RCC


railing of M-30 Grade, aggregate size not exceeding 12 mm, true to line and
grade, tolerance of vertical RCC post not to exceed 1 in 500, centre to
centre spacing between vertical post not to exceed 2000 mm, leaving
adequate space between vertical post for expansion, complete as per m 1790.00
approved drawings and technical specifications complete as per
specifications MORTH Specification No. 2703,1500,1600 & 1700

32.3 KSRRB M2700-3. Construction of RCC railing of M30 Grade in-situ with 20
mm nominal size aggregate, true to line and grade, tolerance of vertical RCC
post not to exceed 1 in 500, centre to centre spacing between vertical post
not to exceed 2000 mm, leaving adequate space between vertical post for m 1756.00
expansion, complete as per approved drawings and technical specifications
complete as per specifications MORTH Specification No. 2703,1500,1600 &
1700

32.4 KSRRB M2700-4. Providing, fitting and fixing mild steel railing complete as
per drawing and Technical Specification complete as per specifications m 2638.00
MORTH Specification No. 2703.2, 1900
32.5 KSRRB M2700-5. Drainage Spouts complete as per drawing and Technical
specification complete as per specifications MORTH Specification No. 2705 No 1552.00

Page 183 of 375


32.6 KSRRB M2700- Approach Slab KSRRB M2700-6. PCC M15 Grade leveling
course below approach slab complete as per drawing and Technical
specification complete as per specifications MORTH Specification No. 2700 cum 5422.00

32.7 KSRRB M2700-7. Reinforced cement concrete M30 approach slab including
reinforcement at 50kgs / cum and formwork complete as per drawing and
Technical specification complete as per specifications MORTH Specification cum 9961.00
No.1500, 1600, 1700 & 2704
32.8 KSRRB M2300 - 16 Provinding and laying cement concrete wearing coat
with OPC cement design mix M30@360 kgs, with 20mm and down size
graded granite metal coarse aggregates @ 0.69 cum and fine aggregates @
0.46 cum, and reinforcement at 75 kgs / cum with superplastisiser@ 3lts
confirming to IS9103-1999 Reaffirmed- 2008 including cost of cum 10300.00
reinforcemnet complete as per drawing and Technical Specifications
complete as per specifications MORTH Specfications No. 2702

Page No. 247


32.9 KSRRB M2700- Precast Pretensioned Girders KSRRB M2700-9. Providing,
precasting, transportation and placing in position precast pretensioned
concrete girders as per drawing and technical specifications including the cum 22909.00
cost high tensiled strands complete as per specifications MORTH
Specification No.1800 & 2300
32.10 KSRRB M2700-10. Providing and fixing Helical pipes in voided concrete
slabs complete as per specifications MORTH Specification No. 1700 & 1800 m 400.00

32.11 KSRRB M2700- Painting on Concrete Surface KSRRB M2700-12. Providing


and applying 2 coats of water based cement paint to unplastered concrete
surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and Sqm 66.00
applying paint at of 1 litre for 2 sqm complete as per specifications MORTH
Specification No. 800
32.13 Providing and laying 3mm thick asphalt seal pad made of actatic
polypropylene polymer (app) modified bituminous pad reinforced with non
woven polyester mat of high bear strength as a carrier (confirming to ASTM Sqm 406.00
- D6222 (S) Specification) on concrete bridge deck slab complete as per
specifications.
Note : For KSRRB 2700-2
1 The Rates for 6mm or any other thickness may be worked out on pro-rata
basis
2 The Quantity of bitumen works out 17% of the mastic asphalt blocks
without aggregates and falls within the standards laid down by MORTH
Specifications.
NOTE : For KSRRB 2700-2 & KSRRB 2700-4
3 Quantities of material have been adopted from standard plans of MORTH
Vide drawing no. SD/202.
NOTE : For KSRRB 2700-6
4 In Case of Viaducts in urban areas, the drainage spotouts should be
connected with suitably located pipelines to discharge the surface run off
to drains provided at ground level
5 In case of bridges, sufficient length of G.I. Pipe shall be provided to ensure
that there is no splashing of water from the drainage spout on the
structure.
Page No. 248

33.0 33.BRIDGES - REPAIR AND REHABILITATION


33.1 KSRRB M2800-1. Removal of existing cement concrete wearing coat
including its disposal complete as per Technical Specification without
causing any detrimental effect to any part of the bridge structure and Sqm 99.00
removal of dismantled material with all lifts and lead complete as per
specifications MORTH Specification No.2809
33.2 KSRRB M2800-2. Removal of existing asphaltic wearing coat comprising of
50 mm thick asphaltic concert laid over 12 mm thick mastic asphalt
including disposal with all lift and lead complete as per specifications Sqm 71.00
MORTH Specification No. 2809
33.3 KSRRB M2800-3. Guniting concrete surface with cement mortar applied
with compressor after cleaning surface and spraying with epoxy complete
as per Technical Specification. MORTH Specification No.2807 Sqm 556.00

Page 184 of 375


33.4 KSRRB M2800-4. Providing and inserting nipples with approved fixing
compound after drilling holes for grouting as per Technical Specifications
including subsequent cutting/removal and sealing of the hole as necessary
of nipples after completion of grouting with Cement / Epoxy complete as No 136.00
per specifications MORTH Specification No. 2800

33.5 “KSRRB M2800-5.1. Sealing of cracks / porous concrete by injection


process through nipples/Grouting complete as per Technical Specification Kgs 250.00
A. Cement Grout” MORTH Specification No. 2806
33.6 “KSRRB M2800-5.2. Sealing of cracks / porous concrete by injection
process through nipples/Grouting complete as per Technical Specification .
B. Cement Mortar (1:1) Grouting” MORTH Specification No. 2806 Kgs 247.00

33.7 KSRRB M2800-6. Patching of damaged concrete surface with polymer


concrete and curing compounds, initiator and promoter, available in
present formulations, to be applied as per instructions of manufacturer and Sqm 676.00
as approved by the Engineer complete as per specifications MORTH
Specification No. 2800
33.8 KSRRB M2800-7. Sealing of crack / porous concrete with Epoxy Grout by
injection through nipples complete as per clause 2800.3.1 complete as per Kgs 396.00
specifications MORTH Specification No. 2803
Page No. 250
33.9 KSRRB M2800-8. Applying epoxy mortar over leached, honey combed and
spalled concrete surface and exposed steel reinforcement complete as per
Technical Specification. MORTH Specification No. 2804 Sqm 446.00

33.10 KSRRB M2800-9. Removal of defective concrete, cleaning the surface


thoroughly, applying the shotcrete mixture mechanically with compressed
air under pressure, comprising of cement, sand, coarse aggregates, water
and quick setting compound in the proportion as per clause 2800.7.1. sand
and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012
respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite Sqm 266.00
not less than 2000 kg/cum, strength not less than 25 Mpa and
workmanship conforming to clause 2800.7.6 complete as per specifications
MORTH Specification No. 2807

33.11 KSRRB M2800-10. Applying pre-packed cement based polymer mortar of


strength 45 Mpa at 28 days for replacement of spalled concrete complete as
per specifications MORTH Specification No. 2800 Sqm 391.00

33.12 KSRRBM 2800-11. Eproxy bonding of new concrete to old concrete


Sqm 573.00
complete as per specifications MORTH Specification No. 2805
33.13 KSRRB M2800-12.1. Providing external prestressing with high tensile steel
wires / strands for taking output of 1 MT, including drilling for passage of
prestessing steel, all accessories for stressing and stressing operation and Tonne 394396.00
grouting complete as per drawing and Technical Specification MORTH
Specification No. 2810
33.14 KSRRB M2800-12.2. Providing external prestressing with high tensile steel
wires /strands for taking output of 3.10 MT, including drilling for passage
of prestessing steel, all accessories for stressing and stressing operation Tonne 287373.00
and grouting complete as per drawing and Technical Specification MORTH
Specification No. 2810
33.15 KSRRB M2800-12.3. Providing external prestressing with high tensile steel
wires / strands for taking output of 9.28 MT, including drilling for passage
of prestessing steel, all accessories for stressing and stressing operation Tonne 257350.00
and grouting complete as per drawing and Technical Specification MORTH
Specification No. 2810
Page No. 251
33.16 KSRRB M2800-13. Replacement of Bearings complete as per Technical
Specification complete as per specifications MORTH Specification No. 2810

33.16.1 KSRRB M2800-13. Replacement of Bearings complete as per Technical


Specification complete as per specifications MORTH Specification No. 2810 Nos 13993.00
- Bearing Rocker & Roller
33.16.2 KSRRB M2800-13. Replacement of Bearings complete as per Technical
Specification complete as per specifications MORTH Specification No. 2810 No 10776.00
- Bearing Neoprene
33.18 KSRRB M2800-15. Replacement of Expansion Joints complete as per
m 2145.00
drawings complete as per specifications
33.19 KSRRB M2800-16. Replacement of Damaged Concrete Railing complete as
m 299.00
per specifications

Page 185 of 375


33.20 KSRRB M2800-17. Replacement of Crash Barrier complete as per
m 578.00
specifications
33.21 KSRRB M2800-18. Replacement of Damaged Mild Steel Railing complete as
m 244.00
per specifications
33.22 KSRRB M2800-19. Repair of Crash Barrier. Repair of concrete crash barrier
with cement concert of M-30 grade by cutting and trimming the damaged
portion to a regular shape, cleaning the area to be repaired thoroughly, m 224.00
applying cement concert after erection of proper form work complete as per
specifications
33.23 KSRRB M2800-20. Repair of RCC Railing Carrying out repair of RCC M-30
railing to bring it to the original shape complete as per specifications m 158.00

33.24 KSRRB M2800-21. Repair of Steel Railing to bring it to the original shape
m 230.00
complete as per specifications
Page No. 252

34.0 34.PIPE CULVERTS


34.1 KSRRB M2900- PCC 1:3:6 in Foundation KSRRB M2900-1. Plain cement
concrete 1:3:6 mix with crushed stone aggregate 40 m nominal size
mechanically mixed, placed in foundation and compacted by vibration cum 4226.00
including curing complete as per specifications MORTH Specification No.
408
34.2 KSRRB M2900-2.1. Laying Reinforced cement concrete pipe NP4 /
prestressed concrete pipe for culverts on first class bedding of granular
material in single row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 9048.00
works in head walls and parapets complete as per specifications. MORTH
Specification No. 2900 A. 1000 mm dia

34.3 KSRRB M2900-2.2. KSRRB M2900-2.1. Laying Reinforced cement concrete


pipe NP4 / prestressed concrete pipe for culverts on first class bedding of
granular material in single row including fixing collar with cement mortar
1:2 but excluding excavation, protection works, backfilling, concrete and m 10145.00
masonry works in head walls and parapets complete as per specifications.
MORTH Specification No. 2900 B. 1200 mm dia MORTH Specification No.
2900

34.4 KSRRB M2900-3.1. Laying Reinforced cement concrete pipe NP4 /


prestressed concrete pipe for culverts on first class bedding of granular
material in double row including fixing collar with cement mortar 1:2 but
excluding excavation, protection works, backfilling, concrete and masonry m 18161.00
works in head walls and parapets complete as per specifications. MORTH
Specification No. 2900 A. 1000 mm dia

34.5 KSRRB M2900-3.2. KSRRB M2900-3.1. Laying Reinforced cement concrete


pipe NP4 / prestressed concrete pipe for culverts on first class bedding of
granular material in double row including fixing collar with cement mortar
1:2 but excluding excavation, protection works, backfilling, concrete and m 20360.00
masonry works in head walls and parapets complete as per specifications.
MORTH Specification No. 2900 B. 1200 mm dia MORTH Specification No.
2900

34.6 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300
34.6.1 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 1534.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 300mm. dia
34.6.2 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 2583.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 450mm. dia
34.6.3 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 3191.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 600mm. dia

Page 186 of 375


34.6.4 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 3468.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 750mm. dia
34.6.5 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 5502.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 900mm. dia
34.6.6 Providing and laying reinforced cement concrete pipe NP3 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 8428.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 1200mm. dia
Page No. 254
34.7 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300
34.7.1 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 391.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - -150mm dia
34.7.2 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 528.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 250mm dia
34.7.3 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 1056.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 300mm dia
34.7.4 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 1439.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 450mm dia
34.7.5 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 2159.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 600mm dia
34.7.6 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 2671.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 750mm dia
34.7.7 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 3383.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 900mm dia
34.7.8 Providing and laying reinforced cement concrete pipe NP2 for culverts
including pointing ends, and fixing collars with cement mortar 1:2
including cost of all materials, labour, curing complete as per m 5638.00
specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300 - - 1200mm dia
34.8.1 Providing and constructing granite / trap / basalt size stone masonry in
foundation with cement mortar 1:8 stone hammerd dressed in courses not
less than 20 cms high, bond stones at two m. apart in each course cum 4494.00
including cost of materials, labour, curing complete as per specifications.
KBS 5.1.13
34.8.2 Providing and constructing granite / trap / basalt size stone masonry in
foundation with cement mortar 1:6 stone hammerd dressed in courses not
less than 20 cms high, bond stones at two m. apart in each course cum 4596.00
including cost of materials, labour, curing complete as per specifications.
KBS 5.1.13

Page 187 of 375


34.9 Providing and constructing granite / trap / basalt size stone masonry in
basement with cement mortar 1:6, edges of stones chistle dressed in
courses not less than 15 cms high, bond stones at two m. apart in each cum 5483.00
course including cost of materials, labour, curing complete as per
specifications.
34.10.1 Providing and constructing granite / trap / basalt size stone masonry in
superstructure with cement mortar & edges of stones chistle dressed in
courses not less than 15 cms high, bond stones at two m. apart in each
course including cost of materials, labour, scaffolding, curing complete as cum 5784.00
per specifications. KBS 5.1.13
- do - with cement mortar 1:6

34.10.2 Providing and constructing granite / trap / basalt size stone masonry in
superstructure with cement mortar & edges of stones chistle dressed in
courses not less than 15 cms high, bond stones at two m. apart in each
course including cost of materials, labour, scaffolding, curing complete as cum 5804.00
per specifications. KBS 5.1.13
- do - with cement mortar 1:4

34.11 Providing and laying in position plain cement concrete of mix 1:2:4 with
cement @ 240kgs, with 20mm and down size graded granite metal coarse
aggregates @ 0.69 cum and fine aggregtes @ 0.459cum, machine mixed,
concrete laid in layers not exceeding 15 cms. thick, well compacted, for
coping. Including cost of all materials, labour, HOM of machinery, curing cum 5283.00
complete as per specifications.Specification No. KBS 4.1, 4.2. (P. No. 247/ I.
No.34.11 of CSR 2015-16)

Page No. 255


34.12.1 Providing flush pointing to square rubble, course or uncoursed stone
masonry with cement mortar, 20mm deep, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing complete as sqm 141.00
per specifications. – do – cement mortar 1:4

34.12.2 Providing flush pointing to square rubble, course or uncoursed stone


masonry with cement mortar, 20mm deep, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing complete as sqm 140.00
per specifications.– do – cement mortar 1:3
34.13.1 Providing ruled pointing to coursed stone masonry with cement
mortar,20mm deep, after raking joints to depth of 20mm nicely lining,
including cost of materials, labour, curing complete as per specifications. – sqm 140.00
do – cement mortar 1:4
34.13.2 Providing ruled pointing to coursed stone masonry with cement mortar,
20mm deep, after raking joints to depth of 20mm nicely lining, including
cost of materials, labour, curing complete as per specifications. – do – sqm 142.00
cement mortar 1:3
34.14 Providing and constucting pithcing / Revetment of 30 cm thick on slopes
using granite/basalt/trap/stones of surface area not less than 0.04 sqm
and wedged with spalls including cost of all materials, labour etc., complete sqm 447.00
as per specification.
34.15 Earth work in excavation for foundation of structures like culverts,
retaining walls etc., as per drawing and technical specification, including
setting out, constuction of shoring and bracing, dressing of sides and
bottom, back filling with approved material, disposal of balance earth as per
specifications, including cost of labour, HOM etc., complete.

34.15.1 In all kind of soil by manual means. cum 180.00


34.15.2 In all kinds of soil by mechanical means. cum 45.00
34.15.3 In ordinary rock/soft rock by manual means. cum 257.00
34.15.4 In ordinary rock/soft rock by mechanical means. cum 55.00
34.15.5 In hard rock with blasting cum 540.00
34.15.6 In hard rock without blasting cum 434.00
34.16 Providing and laying in position plain cement concrete of mix 1:2:4 for sub-
structure works like Culverts, retaining walls etc., with cement @ 240kgs,
with 40mm and down size graded granite metal coarse aggregates @ 0.84
cum and fine aggregtes @ 0.46cum, machine mixed, with necessary cum 4649.00
scaffolding, form work etc., including cost of labour, HOM curing etc.,
complete.

Page No. 256

Page 188 of 375


34.17 Providing and laying in position plain/Reinforced cement concrete M20 for
sub-structure/Superstructure works, with
cement @ 320kgs, with 20mm and down size graded granite metal coarse
aggregates @ 0.69 cum and fine aggregtes @ 0.46cum, machine mixed with
super plasticisers @ 3 lts confirming to IS 9103-2008, concrete laid in
layers, well compacted and providing weep holes wherever necessary with cum 4979.00
necessary scaffolding, form work etc., including cost of labour, HOM curing
etc., complete.

Note :
1 In case of Cement cradle bedding, quanity of PCC M-15 is to be calcualated
as per design and priced separately and added.
2 The rate analysis does not include excavation / cement / masonry works in
head walls, backfilling, protection works and parapet walls. The Same are
to be calculated as per approved design and drawings and priced separately
on rates available under respective chapters
Page No. 257

35.0 35.MAINTENANCE OF ROADS


35.1 KSRRB M3000- Restoration of Rain Cuts KSRRB M3000-1. Restoration of
rain cuts with soil, moorum, gravel or a mixture of these, clearing the loose
soil, benching for 300 mm width, laying fresh material in layers not
exceeding 250 mm and compacting with plate compactor or power rammers m 123.00
to restore the original alignment, levels and slopes complete as per
specifications MORTH Specification No. 3002

35.2 KSRRB M3000- Maintenance of Earthen Shoulder KSRRB M3000-2.


Making up loss of material / irregularities on shoulder to a minimum depth
of 150 mm to the design level by adding fresh approved soil and Sqm 28.00
compacting it with appropriate equipment complete as per specifications
MORTH Specification No.3003
35.3 KSRRB M3000-3. Stripping excess soil from the shoulder surface to a
minimum depth of 150 mm to achieve the approved level and compacting
with plate compactor complete as per specifications MORTH Specification Sqm 15.00
No. 3003
35.4 KSRRB 3000 Filling Pot-holes and Patch Repairs with Open-Graded Premix
Surfacing, 20 mm KSRRB M3000-4. Removal of all failed material,
trimming of completed excavation to provide firm vertical faces, cleaning of
surface, painting of tack coat on the sides and base of excavation as per
clause 500.3, back filling the pot holes with hot bituminous material as per Sqm 193.00
clause 500.11, compacting, trimming and finishing the surface to form a
smooth continuous surface, all as per clause 3004.2 complete as per
specifications MORTH Specification No. 3004.2

35.5 KSRRB 3000 Filling Pot-holes and Patch Repairs with Bituminous
Concrete, 40 mm KSRRB M3000-5. Removal of all failed material, trimming
of completed excavation to provide firm vertical faces, cleaning of surface,
painting of tack coat on the sides and base of excavation as per clause
500.3, filling back the pot holes with hot bituminous material as per clause Sqm 345.00
500.4, compacting, trimming and finishing the surface to form a smooth
continuous surface, all as per clause 3004.2 complete as per specifications
MORTH Specification No. 3004.2

35.6 KSRRB M3000- Crack Filling KSRRB M3000-6. Filling of crack using slow -
curing bitumen emulsion and applying crusher dust in case crack are wider
than 3mm complete as per specifications MORTH Specification No. m 4.00
3004.3.3
Page No. 259
35.7 KSRRB M3000- Dusting KSRRB M3000-7. Applying crusher dust to areas
of road where bleeding of excess bitumen has occurred complete as per m 2.00
specifications MORTH Specification No. 3004.4
35.8 KSRRB 3000 Repair of Joint Grooves with Epoxy Mortar KSRRB M3000-8.
Repair of spalled joint grooves of contraction joints, longitudinal joints and
expansion joints in concrete pavements using epoxy mortar or epoxy m 332.00
concrete complete as per specifications. MORTH Specification No. 3005.1

35.9 KSRRB M3000- Repair of Old Joint Sealant KSRRB M3000-9. Removal of
existing sealant and re sealing of contraction, longitudinal or expansion
joints in concrete pavement with fresh sealant material complete as per m 43.00
specifications MORTH Specification No. 3005.2

Page 189 of 375


35.10 KSRRB M3000- Hill Side Drain Clearance KSRRB M3000-10. Removal of
earth from the choked hill side drain and disposing it on the valley side
manually complete as per specifications MORTH Specification No. 3000 m 54.00

35.11 KSRRB M3000- Landslide Clearance in Soil KSRRBM 3000-11. Clearance of


land slides in soil and ordinary rock by a bull-dozer D 80 A-12, 180 HP and
disposal of the same on the valley side complete as per specifications cum 12.00
MORTH Specification No. 3000
35.12 KSRRB M3000- Landslide Clearance in Hard Rock Requiring Blasting
KSRRB M3000-12. Clearing of land slide in hard rock requiring blasting for
50% of the boulders and disposal of the same on the valley side complete as cum 54.00
per specifications MORTH Specification No. 3000

35.13
Patching of deep potholes by restoring the granular base course using
material confirming to WBM garde -III standards /WMM wherver necessary
by manual means including trimming the pothole to the required shape and
size, cleaning the pothole applying tack coat at 4 kg/10sqm over the
WBM/WMM surface including cleaning etc, and covering the surface with
premixed mix seal TYPE-A 20mm thick including lead, loading unloading,
rolling and finishing etc., Complete as per standard specification.

35.13.1 Patching of deep potholes by restoring the granular base coarse using
material confirming to WBM garde -III standards /WMM wherver necessary
by manual means including trimming the pothole to the required shape and
size, cleaning the pothole applying tack coat at 4 kg/10sqm over the
Sqm 333.00
WBM/WMM surface including cleaning etc, and covering the surface with
premixed mix seal TYPE-A 20mm thick including lead, loading unloading,
rolling and finishing etc., Complete as per standard specification. - - upto
75 mm thick
35.13.2 Patching of deep potholes by restoring the granular base coarse using
material confirming to WBM garde -III standards /WMM wherver necessary
by manual means including trimming the pothole to the required shape and
size, cleaning the pothole applying tack coat at 4 kg/10sqm over the
sqm 426.00
WBM/WMM surface including cleaning etc, and covering the surface with
premixed mix seal TYPE-A 20mm thick including lead, loading unloading,
rolling and finishing etc., Complete as per standard specification. - - upto
150mm thick
Page No. 260
35.14 patching of shallow potholes on asphalt surfaces by using corresponding
standard premixes including removing the failed materials on the road
surface, preparation of potholes to the required standards before patching
them, application of tack coat at 2.5 kg/10 sqm over the asphalt surface
including lead, loading unloading, rolling and finishing etc., complete as per
standard specification.

35.14.1 patching of shallow potholes on asphalt surfaces by using corresponding


standard premixes including removing the failed materials on the road
surface, preparation of potholes to the required standards before patching
them, application of tack coat at 2.5 kg/10 sqm over the asphalt surface Sqm 185.00
including lead, loading unloading, rolling and finishing etc., complete as per
standard specification. - - using MSS Type - A upto 20 mm thick

35.14.2 patching of shallow potholes on asphalt surfaces by using corresponding


standard premixes including removing the failed materials on the road
surface, preparation of potholes to the required standards before patching
them, application of tack coat at 2.5 kg/10 sqm over the asphalt surface Sqm 196.00
including lead, loading unloading, rolling and finishing etc., complete as per
standard - - using SDBC 25 mm thick.

35.14.3 patching of shallow potholes on asphalt surfaces by using corresponding


standard premixes including removing the failed materials on the road
surface, preparation of potholes to the required standards before patching
them, application of tack coat at 2.5 kg/10 sqm over the asphalt surface
including lead, loading unloading, rolling and finishing etc., complete as per Sqm 372.00
standard specification. - - using BM for base coarse 50mm thick and
25mm thick SDBC for finishing

Page 190 of 375


35.14.4 patching of shallow potholes on asphalt surfaces by using corresponding
standard premixes including removing the failed materials on the road
surface, preparation of potholes to the required standards before patching
them, application of tack coat at 2.5 kg/10 sqm over the asphalt surface Sqm 560.00
including lead, loading unloading, rolling and finishing etc., complete as per
standard specification. - - using BM for base coarse 50mm thick and BC
40mm thick for finishing

35.15 Supplying, placing & compacting ready made cold bituminous pothole
patching mix in accordance with IRC 116-2014 in 50 kg plastic sturdy
bags. The mix shall contain at least 5.6% MC 800 cutback Bitumen & 50 Kg Bag 336.00
suitable anti-stripping agent. The mix shall be workable for at least 6
months.
Note :
1 The Earth stripped from earthen shoulders to be dumpted on the side
slopes locally for disposal
2 The Constituents of epoxy mortary/epoxy concrete will be as per the
instruction and manual of the manufacturer.
3 35.14.3 & 35.13.2 Should be operated after obtaining approval from S.E.

Page No. 261

36.0 36.REINFORCED EARTH STRUCTURE


36.1 KSRRB M3100-2. Assembling, joining and laying of reinforcing elements. A.
With reinforcing element of steel / aluminium strips / polymeric strips m 236.00
MORTH Specification No. 3102
36.2 KSRRB M3100-3. Assembling, joining and laying of reinforcing elements B.
With reinforcing element of synthetic geogrids MORTH Specification No. Sqm 323.00
3102
36.3 KSRRB M3100-4. Facing Elements of RCC MORTH Specification No. 3104
Sqm 1766.00

Note :
1 The Specification and construction details to be adopted shall be as per
section 3100 of MORTH Specifications
2 Drainage arrangement shall be made as per approved design and drawings

3 For compaction of Earthwork, attention is invited to clause 3105.5 of


MORTH Specifications.
4 Length of reinforcing strip will vary with the height of wall and will be as per
approved design and drawings.
Page No. 263
5 The earth fill material shall be clean, free draining, granular with high
friction and low cohesion, non-corrosive, coarse grained with not 10 percent
of particles passing 75 microns sleve, free of any deleterious matter,
chlorides, salts, acids, alkalie.
6 The Cost of reinoforced earth retaining wall shall include following :
i) Excavation for foundation including backfilling
ii) Foundation concrete as per approved design
IV) Cost of reinforcing elements including theilr fixing and joining with the
facial pannels.
V) Drainage arrangement including filter media as per approved design

7 The Compacted earth filling to be retained shall from part of embankment

Page No. 264

37.0 37.OTHER ITEMS


37.1 Providing erecting and removing casurinapole Barricading using poles of
7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at intervals
of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above ground level,
including fixing poles in the ground level for minimum depth of 0.30 mtr
and tied with coir rope firmly including cost and conveyance of all
materials, labour, lead and lift charges and complete.

37.1.1 Providing erecting and removing casurinapole Barricading using poles of


7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at intervals
of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above ground level,
including fixing poles in the ground level for minimum depth of 0.30 mtr m 57.00
and tied with coir rope firmly including cost and conveyance of all
materials, labour, lead and lift charges and complete. - - For two tier
Barricading

Page 191 of 375


37.1.2 Providing erecting and removing casurinapole Barricading using poles of
7.50 to 10 cms. Dia and 1.5 height above ground fixed vertically at intervals
of 2.0 to 2.5 mtrs. C/C and Horizontally at 0.50 mtrs, above ground level,
including fixing poles in the ground level for minimum depth of 0.30 mtr m 73.00
and tied with coir rope firmly including cost and conveyance of all
materials, labour, lead and lift charges and complete. - - For three tier
Barricading

37.2 Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of
65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm
dia M.S. hold fast rods each of length 25 cms. Including cost of all materials
cutting, bending scaffolding wherever necessary, nicely finishing the welded
joints with all lead lifts and as per the directions of the Engineerin - charge m 859.00
of the work and including providing 2 coats of approved quality paint over
one coat of shop painting ( excluding cost of earthwork and concrete)

37.3 Providing chain link fencing 50mm size of 8 guage properly stretched
between existing rectangular poles and fixed with suitable bolts & nuts, the
free ends shall be welded to the pole and block pipe at top and bottom as
required including cost of all materials, labour, lead and lifts and as per the Sqm 715.00
directions of the Engineer-in-charge of work including two coats of
approved quality paint over one coat of shop paint

37.4 Providing and fixing M.S. Block pipe of 38mm dia, of heavy guage of 14
including removing the bends, cutting the pipe, and fixing pipe in between
the existing two verticle poles (M.S. rectangular poles) and spot welding the
chain link with M.S. block pipe including cost of all materials wastage in
cutting, and scaffolding wherever necessary with all lead and lift as directed m 408.00
by the Engineer-in-charge of work etc., complete including two coats of
approved quality paint over one coat of shop paint.

37.5 Providing barbed GI wire fencing of 12x12 gauge drawn into stone pillars or
iron pillars including drawing in holes wherever necessary excluding the
cost of pillars but including the cost of barbed wire and binding wire etc., m 32.00
complete.
37.6 Providing corrugated cement asbestos Ridge sheets set in C.M. 1:3 and
m 416.00
pointed with C.M. 1:3.
37.7 Providing Mangalore Ridge tiles set in C.M. 1:2 and pointed with C.M. 1:2.
m 204.00
(P.No.255, I.No.37.7 of PWD SR 2015-16)
Page No. 266
37.8 Fixing doors, window and ventilators in walls. No 237.00
37.9 Supplying and fixing new Mangalore tiles on existing reepers. (P.No.256,
Sqm 407.00
I.No.37.15 of PWD SR 2015-16)
37.10 Removing and fixing old Mangalore ridge tiles including pointing with C.M.
m 102.00
1:3.
37.11 Repairs to roof with available corrugated zinc sheets/ A.C.sheets with new
Sqm 102.00
J bolts, screws and washers etc., on existing reeper and rafters.
37.12 Repairing door and window frames with available wood to the required size.
Sqm 686.00
(P.No.256, I.No.37.12 of PWD SR 2015-16)
37.13 Repairing and fixing shutters (panelled or glazed) to doors, windows,
Sqm 686.00
ventilators and cupboards.
37.14 Fixing old eve board with necessary screws and approved painting two
m 26.00
coats.
37.15 Providing and fixing plain rolled glass 3mm thick with T.W beading of
Sqm 611.00
10mm thick. (P.No.256, I.No.37.15 of PWD SR 2015-16)
37.16 Providing and fixing 4mm thick glass panes to steel windows including T.W.
beading of 10 mm thick and 2 coats of approved paints. Sqm 792.00

37.17 Easing of shutters of door. (P.No.256, I.No.37.17 of PWD SR 2015-16) No 87.00


37.18 Easing of window shutters. (P.No.256, I.No.37.18 of PWD SR 2015-16) No 84.00
37.19 Providing and fixing M.S bars to windows and ventilators including cutting
Kgs 131.00
making holes in frame work with two coats of approved paints.
37.20 Labour charges for fixing iron bars to windows including cutting fixing and
making holes in the frame work and painting two coats with approved paint Kgs 86.00
etc., complete (excluding the cost of iron bars)
37.21 Repairs to cornice or coping or mortar band, 15 cm deep and 8cm
Sqm 102.00
projection for damaged portion.
Page No:267
37.22 Removing cuddappa slab flooring and stacking the material with a lead of
Sqm 49.00
50 meters.
37.23 Removing and resetting Mangalore tiles and replacing broken ones
Sqm 25.00
wherever necessary (excluding cost of new tiles).
37.24 Cleaning glass with chemicals. (P.No.256, I.No.37.24 of CSR 2015-16) Sqm 15.00

Page 192 of 375


37.25 Removing and refixing existing mortar and pestle stone. Each 257.00
37.26 Removing by chiselling cement joints 50mm to 80mm deep in pipes upto
Sqm 49.00
150mm dia.
37.27 Labour charges for fixing plain, frosted or pin headed glass panels (clear
Sqm 359.00
glass area) with teak wood beading.
37.28 Drilling holes of 2.50 cms dia (roof/chajja/stone).
37.28.1 Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 7.50
No 131.00
cms thick
37.28.2 Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 10 cms
No 157.00
thick
37.29 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the
exposed faces
37.29.1 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the Set 523.00
exposed faces - - 50 cms x 50 cms x 60 cms
37.29.2 Providing and fixing mortar and pestle stone with suitable size of pestle
stone including three line dressing for top and two line dressing for the Set 419.00
exposed faces - - 40 cms x 40 cms x 40 cms
37.30 Providing wall black boards in CM 1:3 with two coats of black paint
Sqm 781.00
including finishing etc., complete.
37.31 Providing and fixing mortise locks heavy duty to doors. Each 568.00
37.32 Providing and fixing hydraulic door closures-with mounting heavy duty.
No 1417.00

37.33 Providing and fixing hydraulic door closures-Aluminium body. No 987.00


37.34 Cleaning of glazed tiles. (P.No. 257, I.No. 37.34 of PWD SR 2015-16) Sqm 68.00
Page No. 268
37.35 Wall bores in Brick masonry upto 45 cm thick. Each 126.00
37.36 Wall bores in size stone masonry
37.36.1 Wall bores in size stone masonry - - upto 45 cm thick. Each 303.00
37.36.2 Wall bores in size stone masonry - - upto 60 to 90cm thick. (P.No. 257/
Each 329.00
I.No.37.36.2 of CSR 2015-16)
37.36.3 Wall bores in size stone masonry - - upto 90 to 120 cm thick. Each 379.00
37.37 Cutting of road surface for pipeline trenches and disposing of the excavated
stuff as directed including barricading, danger lighting etc., in the cum 299.00
Macadam road.
37.38 Cutting of road surface for pipeline trenches and disposing of the excavated
stuff as directed including barricading, danger lighting etc., in the Asphalt cum 449.00
surface road. (P.No.257/I.No. 37.38 of CSR 2015-16)
37.40 Cutting of road surface for pipeline trenches and disposing of the excavated
stuff as directed including barricading, danger lighting etc., in the Cement cum 686.00
concrete road.
37.41 Diversion of water course by providing Coffer dams or bunds or islands as
may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete.

37.41.1 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete. - - cum 296.00
1.50 mtrs depth below LWL.
37.41.2 Diversion of water course by providing Coffer dams or bunds or islands as
may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete. - - cum 394.00
beyond 1.50 mtrs depth upto & including 3m depth.

37.41.3 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete. - - cum 649.00
beyond 3.00 mtrs depth upto & including 4.5m depth.

37.41.4 Diversion of water course by providing Coffer dams or bunds or islands as


may be necessary for piers and abutments foundations, bailing out or
pumping water during excavation and until completion etc., complete. - - cum 802.00
beyond 4.50 mtrs depth upto & including 6.00m depth.

37.42 Dismantling Mangalore tiles roof and stacking the material within a radius
of 50 meters.
37.42.1 Dismantling Mangalore tiles roof and stacking the material within a radius
of 50 meters. - - with reepers. (P.No. 257, I.No. 37.42.1 of SR 2015-16). Sqm 74.00

Page 193 of 375


37.42.2 Dismantling Mangalore tiles roof and stacking the material within a radius
of 50 meters. - - without reepers. (P.No. 257, I.No. 37.42.2 of SR 2015-16). Sqm 49.00

37.42.3 Dismantling Mangalore tiles roof and stacking the material within a radius
Sqm 99.00
of 50 meters. - - A.C. sheet roofing.
37.43 Dismantling CI or AC rain water Pipes with fittings and clamps and
Sqm 25.00
stacking the materials with a lead of 50 meters.
37.44 Dismantling weather proof course and removing and conveying the debris
to a distance upto 200m. (P.No. 258, I.No. 37.44 of CSR 2015-16). cum 740.00

Page No. 269


37.45 Dismantling Madras terrace jack arch roof including rafters and stacking
the materials with a lead upto 50m and removing the debris to a distance Sqm 247.00
upto 200m.
37.46 Dismantling stone slab roofing over wooden reepers or RCC battens
(dismantling reepers and battens to be paid for separately) including
stacking of serviceable materials and disposal of unserviceable within 200m Sqm 247.00
lead (with in average thickness of 10 cms
37.47 Dismantling burnt brick masonry in clay mortar/lime mortar/cement
mortar and stacking the bricks within a radius of 50m and removing the
debris to a distance upto 200m. (P.No. 258, I.No. 37.47 of SR 2015-16). Sqm 247.00

37.48 Dismantling size stone masonry in clay mortar and stacking the size stone
within a radius of 50m and removing the debris to a distance upto 200m. cum 271.00

37.49 Dismantling the tile work in floor and roof laid in cement or surki mortar
including stacking the materials with in 50 m lead of tiles thickness 10mm Sqm 49.00
to 25mm. (P.No. 258, I.No. 37.49 of SR 2015-16).
37.50 Dismantling plastering and removing the debris with a lead upto 200m.
Sqm 37.00
(P.No.258, I.No. 37.50 of PWD SR 2015-16)
37.51 Dismantling cement concrete flooring or plain cement concrete work
including removing and conveying the debris to distance upto 200m (within Sqm 86.00
average thickness of 15 cms).
37.52 Dismantling barbed wire or flexible wirer rope in fencing including making
m 7.00
rolls and stacking within 50m lead.
37.53 Dismantling expanded metal or IRC fabric with weld mesh necessary
battens and beading etc., including stacking the serviceable materials Sqm 25.00
within 50 m lead.
37.54 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge
with Mathi or Nandi wood patties of 50 mm x 12 mm size, including two
coats approved paint etc., complete. (Including cost of screws). Sqm 1489.00

37.55 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge


with Mathi or Nandi wood patties of 50 mm x 12 mm size, including two
coats approved paint etc., complete. (Including cost of screws). with weld Sqm 1483.00
mesh 75 mm X 25 mm 6G X 10G.
37.56 Removing and resetting of footpath slab Sqm 197.00
37.57 Removing and resetting of kerb stones Rmtr 99.00
Page No. 270
37.59 Providing and laying palin / reinforced cement concrete for side drains
using M20 nominal mix concrete with OPC cement at 300kgs. with 20mm
and down size granite metal coarse aggregates at 0.69 cum and fine
aggregates at 0.43 cum machine mixed, well compacted for for walls and
bottom including centering, shuttering, cost of materials, HOM of machiner,
curing etc., complete excluding cost of steel as per MORTH Specification
No. 1500,1700,2200

37.59.1 .do. walls & bottom thickness 10cm cum 6862.00


37.59.2 .do. walls & bottom thickness 15cm cum 6670.00
37.60 Providing and fixing RCC name board of size 1.35xk0.60x0.04 mtrs fixed in
reinforced cement concrete poles of size 0.10x0.10x2.60mtrs in cement
concrete M 20 proportion using 20mm and down size graded metal
machine mixed with 10mm dia main steel bars and 8mm dia stirpes as
shown in drawing. The board shall be provided with 12mm thick cement
plaster in cement mortar 1:3 on both the sides. The poles shall be
embedded in the ground for a depth of 0.5 mtrs with cement concrete M 10
proportion. The board shall be fixed as per the drawing and at the place Each 5500.00
indicated by the Engineering charge of the work. The cost includes
excavation, cost of all materials, cost of steel, centering, transportation
charges, fixing charges etc., The work shall be carried out as per the
detailed specifications, drawings and directions of the Engineer in charge of
the work.

Page 194 of 375


37.61 Providing and fixing sign board of size 60x60cm equilateral triangle using
M.S sheet 5mm thick with RCC pole of size 0.15x0.15x2.3 mtr made out of
cement concrete M 20 proportion using 20mm and down size graded metal
machine mixed with 10mm dia main steel bars and 8mm dia stirupps as
shown in drawing. The poles shall be embedded in the ground for a depth of
0.6mtrs with cement concrete M 10 proportion. The board shall be fixed as
per the drawing and at the place indicated by the Engineering charge of the Each 3500.00
work. The cost includes excavation, cost of all materials, cost of steel,
centering, transportation charges, fixing charges etc., The work shall be
carried out as per the detailed specifications, drawings and directions of the
Engineer in charge of the work.

37.62 Providing and constructing informatory name board of size 1.75m x 1.75m
with Burnt brick masonry in CM 1:6 with non-modular bricks of standard
size of class designation 50 (table moulded). The foundation shall be
provided with cement concrete M 7.5 for a depth of 10cms and with size
stone masonry with Cement Mortar 1:6 and copping concrete with cement
concrete M 10 as indicated in the drawing. The name board shall be
provided with 12mm thick plaster in CM 1:6 on both the sides including
rounding of corners. The name board shall be provided with painting with 2 Each 6900.00
coats of enamel paint. The board shall be fixed as per the drawing and at
the place indicated by the Engineering charge of the work. The cost
includes excavation, cost of all materials, centering, transportation charges,
fixing charges etc., The work shall be carried out as per the detailed
specifications, drawings and directions of the Engineer in charge of the
work.

Page No:271
37.63 Providing two bulb underreemed pile foundation upto maximum 5m depth
including hire charges of machineries digging the pile holes, labour charges
and laying 20mm and down size jelly RCC M 20 keeping the reinforcement
edge cutting etc., complete as per specifications.

37.63.1 Providing two bulb underreemed pile foundation upto maximum 5m depth
including hire charges of machineries digging the pile holes, labour charges
and laying 20mm and down size jelly RCC M 20 keeping the reinforcement m 909.00
edge cutting etc., complete as per specifications. - - 23 cm dia

37.63.2 Providing two bulb underreemed pile foundation upto maximum 5m depth
including hire charges of machineries digging the pile holes, labour charges
and laying 20mm and down size jelly RCC M 20 keeping the reinforcement m 1483.00
edge cutting etc., complete as per specifications. - - 30 cm dia

37.64 Providing and fixing RCC precast fencing pole of size 0.15m x 0.15m x2.0m
casted in CC 1:1.5:3 with 20mm downsize aggregate making holes for
drawing barbed wire at 30cm c/c using 10 mm dia vertical 4 TMT steel rods
and 8mm dia stirrups at 15cm c/c fixed 1.5m above ground level using
steel moulding, curing, transportation to work spot including excavation in Each 1761.00
hard soil fixing in plain cement concrete 1:2:4 using 20mm downsize
aggregate including aligning to plumb and line providing including cost of
all materials, labour, hire charge of machineries lead, lift loading &
unloading etc.,Complete.

37.65 Providing and laying 100mm thick pre-cast U-shaped RCC drains using
M20 grade concrete reinforced with steel @ 5.00 Kg/Sqm, Precast units and
jointed in CM 1:3 proportion and neatly finished including cost of
labour,materials, HOM, curing, lead and lift charges etc, Complete as per
MORTH specifications No. 1500, 1700.
37.65.1 With size of 450 mm X 450 mm inner dimensions m 1639.00
37.65.2 With size of 450 mm X 600 mm inner dimensions m 1949.00
37.66 Providing and laying 100mm thick pre-cast cover slabs over drains of width
not exceeding 800mm using M20 concrete reinforced with steel @ 6.00
Kg/Sqm, slabs jointed in CM 1:3 proportion and nicely finished including
providing holes in the Cover slabs wherever necessary for easy drainage of m 1081.00
surface water including of labour,materials, HOM, curing, lead and lift
charges etc, Complete as per MORTH specifications No. 1500, 1700.

Page No. 272

38.0 38. INNOVATIVE ITEMS

Page 195 of 375


38.1 WATER PROOFING TO CONCRETE SURFACES Using Membrane
Technology For raft & retaining wall Providing & applying water proofing to
concrete surfaces using high quality polymer-modified bituminous
compounds (confirming to ASTM D
5147) reinforced with non woven polyester fabric, weighing 180gm/sqm
granular finish 4mm thick by torch on application method confirming to the
properties indicated below. It shall be provided after priming the surface
using bitumen primer at 0.2 ltr /sqm.
Detailed specification & Methodology
1. Membrane thickness 4mm (+ or – 5%)
2. Tensile strength – Longitudinal 790 N/5cm Transverse 730 N/5cm
3. Elongation of Membrane - Longitudinal 65% Transverse 69%
4. Tear Resistance - Longitudinal 180 N Transverse 190 N Sqm 430.00
5. Lap joint strength - Longitudinal 750 N/5cm Transverse 550 N/5cm
6. Puncture Resistance – Static 1.4 Dynamic 1.3
7. Water absorption - < 0.15%
8. Water permeability - Nil
9. Chemical resistance – Chloride, sulphate and Nitrate
The area to be water proofed shall be free from loose aggregate, dust free
and in dry condition. Primer must be applied to the surface and allowed to
dry prior to application of membrane. The membrane shall be applied
within 6 hours after application of primer. The membrane comes in a roll
form shall be unrolled and placed in the correct position where it has to be
torched. Each layer must over lap the next layer by min 10cm at the
adjacent and 15cm at the ends. The heat application through propane gas
torch shall be applied on membrane thus causing melting and subsequent
38.2 For roof slab & terraces Providing & applying water proofing to roof slab,
terraces, landscape area, podium etc., using modified polyurethane cures
(conforming to ASTM C836-84) to give a tough elastomeric waterproof
membrane on the surface. The surface shall be cleaned free from dust and
other particle before usage. standards & methodology :
This compound has a medium viscosity grade with 620% of elongation and
shall be done either by roller application/brush application/ spray. This
Sqm 625.00
will be applied for a thickness of 1.3mm first layer 0.5mm & 2nd layer
0.8mm. After applying the 2nd layer sand sprinkle shall be done to provide
mechanical key.

38.3 ISOPROOF SEALER Providing waterproof treatment to roof slab using 2


coats of acrylic co polymer elastomeric ISOPROOF sealer & protector. The
surface shall be prepared free of tar, dust, fungus, loose particles etc.,The
surface shall be applied with basecoat of crystallization liquid and then
ISOPROOF, wetting agent and liquid (1:1:6) over the prepared surface. In
addition the surface shall be provided with polysulphide/ acrylic sealant to
V groves, making haunch at junction of parapet and roof slab and at
damaged portion using patching mortar to drain off rain water. Over this
one coat of flexible cementatious membrane (FCM), Spreading 2 layers of 40
gsm non woven geotextile membrane as reinforcing material (over FCM)
with one primer coat of ISOPROOF
& applying second coat of ISOPROOF liquid over the primer coat -
conforming to ASTM D 412 - 1992. The work shall be carried out as per
the directions of the Engineer in charge. standards &
methodology :
1. surface Preparation
The surface shall be made free from all dirt, fungus, loose particles by using
wire brush. The surface shall be cleaned with solvent like xylene, Toluene, Sqm 980.00
Benzene, dilute hydro chloric acid.
i) Cutting of ‘V’-Grooves : The V shaped grooves shall be cut along the
location of all the visible cracks. The ‘V’-Grooves shall be of size 5mm as
directed by the Engineer in charge.
2. Primary reduction of water permeability
The concentrated crystallization liquid of specific gravity 1.09 is lightly
diluted and applied on the prepared surface. The sodium acetate formed
during the chemical reaction penetrates inside the pores of the concrete
and reacts with water to form crystals to block the pores of the concrete,
there by reducing water permeability.
3. Porosity and voids reduction (base Coat application)
Applying wetting agent consisting of acrylic monomer, co-polymer liquid
and crystallization liquid as base on the prepared surface and V groove and
cracks etc.
4. application of sealant / Patching mortar
Cracks will be sealed using suitable sealant or patching mortar. These
make them ideally suited for joint treatment. Its adhesion is very strong &
Page No. 275

Page 196 of 375


38.4 Atotic Polyproyelene Providing and laying Water proofing with single layer
of 3mm thick granule finish @ 4.5kg/sqm using Atotic Polypropylene
membranes (APP) with overlap of 100mm at every joints including applying
bitumen emulsion priming coat over the dry surface, including scarifying
the surface and removing dust and foreign materials removing debris and Sqm 450.00
cleaning surface with wire brush to give even surface. The work shall be
carried out as per the instructions of Engineer in charge of the work.

38.5 Admixture for concrete mix Concrete structures including water retaining
structures Providing admixture to concrete mix using INTEGRAL
CRYSTALINE admixture. Integral Crystalline Admixture shall be added
@0.8% by weight of cement to the ready mix concrete / concrete at the
time of batching conforming to ASTM C 1202 & DIN V 18998.
methodology :
mixing: Admixture must be added to the concrete at the time of batching at
0.8% by weight of cement. The sequence of procedures for addition will vary
according to the type of batch plant operation and equipment:
addition of admixture to rmC transit mixer / Concrete mixer: Mix
Admixture with water to form a very thin slurry 1 powder : 1.26 liters of
water (e.g. 18 kg of powder mixed with 22.7 liters of water). Pour this
material into the drum of the ready-mix truck/ concrete mixer. The Kgs 360.00
aggregate, cement and water should be batched and mixed in the plant in
accordance with standard practices (taking into account the quantity of
water that has already been placed in the ready-mix truck). Mix for at least
5 minutes to ensure even distribution of the Admixture throughout the
concrete.
addition of admixture to the batching Plant: Add Admix to the coarse
aggregates and sand, then mix thoroughly for 2 – 3 minutes before adding
the cement and water. The total concrete mass should be blended using
standard practices. In case of a fully automated Batching plant, the Admix
shall be poured in the dry form (in the required pre- measured quantity) to
the coarse aggregates and sand while the same is being fed to the batching
plant through the conveyor belt.
Note: It is important to obtain a homogeneous mixture of Admixture with
Page No. 277
38.6 For Construction joints Providing pressure grouting for construction joints
with cement grout mixed with plasticised expanding grout admixtureat 225
grams/bag of cement conforming to BS:8110 part 1 - 1985, Section
8,9,4.6. methodology:
The admixture, cement and water shall be added in the ratio of 225
Point 95.00
gram/bag of cement /21 ltrs of water. This shall be applied to concrete
joints at a pressure of 2 to 4 kg/cm2 by using pumping equipments. The
admixture shall confirm to ASTM C827 and shall have unrestrained
expansion upto 4%

38.7 Water retaining Structures Providing & applying water proofing to concrete
surfaces using crystalline capillary water proofing system at 1 kg per sqm
for concrete surfaces (confirming to ASTM D 4060, D4541) followed by
application of 2 coats of 1mm thick acrylic polymer based cementatious
coating. This crystalline water proofing compound in powder form shall be
mixed with water at
3:1 ratio (3 powder : 1 water) at the time of application.
methodology:
The surface shall be pre damped with water. The water shall be mixed
powder in the ratio of 3 powder :1water mixing thoroughly with a slow
Sqm 475.00
speed drill fitted at a speed RPM of 282640. The final crystalline slurry shall
be applied with a soft brush bloom at average of 1 kg /sqm area. Curing
shall be minimum of 48 hour by treating the surface by fog spray
3 to 4 time a day. Acrylic / Liquid polymer compound shall be mixed with
water by means of using a slow speed drill mixer 500 RPM and gradually
adding the powder component to the liquid avoiding lump formation and
mixed for 2 to 4 minutes. The slurry shall be applied using stiff brush in 2
coats that forms 1mm thick. (0.5 mm thick each coat) Curing shall be
minimum of 48 hour by treating the surface by fog spray 3 to 4 time a day.
Protection layer such as plastering or concrete screen shall be applied on
the water proof membrane surface.
Page No. 278
38.8 COVING Providing and laying 12mm thick coving at the junction of slab
and vertical offsets with CM 1:3 admixed with modified styrene
butadiene rubber emulsion (confirming to BS 6319) specially designed for
use as a bonding aid and gauging liquid for cementations system (5 ltrs for
50kg cement). methodology:
Rmtr. 150.00
Modified styrene butadiene rubber emulsion shall be added to dry mix of
cement mortar of 1:3 (5 ltrs for 1 bag of cement and 3 bags of cement)
mixed thoroughly by adding water 0.35 water cement ratio and peddling for
2 minutes.

Page 197 of 375


38.9 Swellable rapid expansion water proofing for construction joints in all types
of concrete works / composite works Providing and water proofing
treatment to construction joints of all types of concrete works using
swellable rapid expansion in water. Water stop capable of expanding 215%
in 120 hours, when immersed potable water Conforming to ASTM D 297 &
ASTM D 6 Standard methodology:
The water stopper shall be laid as per following steps:
i. Clean the surface sufficiently to receive the water stopper
ii. Apply a coat of primer to the area where water stopper is to be laid
placed at an application rate of 240 running meters per 3.78 Liters of
primer (primer is supplied along with water stopper)
iii. Using moderate hand pressure with the heel of the hand, press a
continuous bead of Water Stopper firmly into the position. Make sure that
the product has bonded to the primed area.
iv. Peel the protective backing form the exposed side of the water stop and
tightly butt the coil ends to form a continuous water stop. Do not overlap m 490.00
the water stop.
v. Follow standard concrete pouring procedures here after.
The proposed water stopper shall be used for the following situations:
1. At all the cold construction joints
2. At the junction of Horizontal Raft and vertical retaining walls
3. At the Junction of horizontal Roof slab and vertical Parapet walls
4. At all cold construction joints in Water retaining structures such as
water tanks, swimming pools, water bodies on Podium, roof garden or
Flower beds etc.
5. Around the Pipe penetrations, metal penetrations, any other
penetrations, where there is a joint between two different surfaces
– one of the surfaces being Concrete.
6. Construction joints in the lift Pits

Page No. 279


38.10 FOR CRACKS IN ROOFTOP SURFACES Providing Water proofer Capable of
bridging cracks upto 2mm in the Exposed Roof surface using Spray
Applied Liquid Water proffer at the rate of 0.20 ltr/sqm. Primer & chemical
mortar shall be applied before applying this spray liquid water proofer. The
area shall be cleaned by high pressure water jet/wire bush or by
mechanical means to make it free from loose particle, dust dirt etc.
methodology :
1. The first part consisting of grouting the porous slab area with non-
shrink cementatious grout (if required).
2. The second part consisting of treating the cracks and construction joints
by routing-out to a minimum 20mm x 20mm groove and filling it with a
crystalisation Mortar after priming with crystalisation slurry.
3. The third part consisting of making vata at the interface joint of the slab
and parapet with crystalisation Mortar.
4. The fourth part consisting of sealing all joints of outlet drains pipe, etc.
with crystalisation Mortar.
5. The fifth part consisting of providing and applying liquid water proofer
which can be spray applied at a coverage of 0.2 lt/ sqmt “to permanently fix
non-soluble crystalline growth throughout the capillary tracts and pores of
concrete. It is spray applied over the entire terrace concrete slab and
parapet walls up to 300 mm height
38.10.1 FOR CRACKS IN ROOFTOP SURFACES Providing Water proofer Capable of
bridging cracks upto 2mm in the Exposed Roof surface using Spray
Applied Liquid Water proffer at the rate of 0.20 ltr/sqm. Primer & chemical
mortar shall be applied before applying this spray liquid water proofer. The Rmt 95.00
area shall be cleaned by high pressure water jet/wire bush or by
mechanical means to make it free from loose particle, dust dirt etc. _ for
crack filling

38.10.2 FOR CRACKS IN ROOFTOP SURFACES Providing Water proofer Capable of


bridging cracks upto 2mm in the Exposed Roof surface using Spray
Applied Liquid Water proffer at the rate of 0.20 ltr/sqm. Primer & chemical
mortar shall be applied before applying this spray liquid water proofer. The Sqm 350.00
area shall be cleaned by high pressure water jet/wire bush or by
mechanical means to make it free from loose particle, dust dirt etc._ for
applying spray

Page 198 of 375


38.11 FOR TOILETS SUNK PORTIONS
Providing INTEGRAL CRYSTALINE Waterproofing treatment to the
sunken portion of Toilets. Using Crystalline Slurry of approved make @
1.4kg per SQM in two coats (0.7 kg per sqm per coat) conforming to ASTM
C 1202 & DINV 18998 standards.
Methodology:
1. The first part consisting of grouting the porous slab area with
non-shrink cementatious grout (if required).
2. The second part consisting of treating the cracks and construction
joints by routing-out to a minimum 20mm x 20mm groove and treating
it with crystalisation Mortar. First it is primed with crystalisation
slurry and later filled with crystalisation mortar and later again a
coat of crystalisation slurry.
3. The third part consisting of making required slopes at the interface
Sqm 500.00
joint of the toilet slab and masonry wall with crystalisation Mortar..
4. The fourth part consisting of sealing / packing all joints of outlet
pipes, etc. with CRYSTALISATION MORTAR
5. The fifth part consisting of providing and applying In-depth Crystalline
Waterproofing System @ 1.4 kgs/sqm in 2 coats to permanently
fix non-soluble crystalline growth throughout the capillary
tracts and pores of concrete. The In-depth Crystalline waterproofing
Material shall be applied by brushing as per manufacturer’s
specification . on the entire toilet sunken slab and walls.

Page No. 280


38.12 SELF CURING COMPOUND FOR CONCRETE SURFACE
(WATER/ WAX BASED)
Providing & applying water based (WB) / wax based low viscosity wax
emulsion curing compound membrane / layer applied in the form of spray
over the concrete surface. The material consists of self curing compound
membrane satisfying ASTM C309-90 standard ensuring a non penetrating
continuous film on the concrete surface covering an area of 4.5 to 5 sqm
Sqm 17.00
per ltr of curing compound and shall be applied with a distance of 45 cms
after 5 hours of concreting to get the best results. This item shall be
adopted wherever there is scarcity of water and with prior approval of
Superintending Engineer.

38.13 POLYMER BASED


Providing & applying high efficiency polymer based curing compound
membrane / layer applied in the form of spray over the roof surface. The
material consists of self curing compound membrane satisfying greater
curing efficiency when tested to BS 7542 -1992 standard ensuring a non
penetrating continuous film on the concrete surface, covering an area of 3.5
to 5 sqm per liter of curing compound and shall be applied with a distance
Sqm 38.00
of 45 cms after 5 hours of concreting to get the best results. The above
items shall be adopted wherever there is scarcity of water and with prior
approval of Superintending Engineer.

Page No. 281


38.15.1 RBI GRADE-81
Pulverising the local soil in place, spreading with rotavator duly adding
the specified quantity of inorganic Compound RBI Grade 81 as
approved by CRRI, mixing thoroughly, sprinkling desired quantity of
water, grading with motor grader and compacting with the road roller
at OMC to the desired density for improving the subgrade & shoulders.
(The laboratory CBR of the compacted soil shall not be less than 10)

38.15.1.1 RBI GRADE-81


Pulverising the local soil in place, spreading with rotavator duly adding the
specified quantity of inorganic Compound RBI Grade 81 as approved by
CRRI, mixing thoroughly, sprinkling desired quantity of water, grading with
motor grader and compacting with the road roller at OMC to the desired
density for improving the subgrade & shoulders. (The laboratory CBR of the cum 680.00
compacted soil shall not be less than 10)
For soils having WL between 35 & 50, with 1% of inorganic
Compound like RBI Grade 81 by weight of Soil.

Page 199 of 375


38.15.1.2 RBI GRADE-81
Pulverising the local soil in place, spreading with rotavator duly adding the
specified quantity of inorganic Compound RBI Grade 81 as approved by
CRRI, mixing thoroughly, sprinkling desired quantity of water, grading with
motor grader and compacting with the road roller at OMC to the desired
density for improving the subgrade & shoulders. (The laboratory CBR of the cum 1263.00
compacted soil shall not be less than 10)
For soils having WL more than 50, with 2% of inorganic Compound like RBI
Grade 81 by weight of Soil.

38.15.2 RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising
and mixing 80% Gravel Soil and 20% Aggregates (30mm nominal size),
spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for
preparing the Base / Sub Base Layer (The Laboratory CBR of the gravel
soil shall not be less that 9%) including cost of all materials, labour, HOM
of Machineries complete as per specification.

38.15.2.1 RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising
and mixing 80% Gravel Soil and 20% Aggregates (30mm nominal size),
spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for
preparing the Base / Sub Base Layer (The Laboratory CBR of the gravel
cum 1763.00
soil shall not be less that 9%) including cost of all materials, labour, HOM
of Machineries complete as per specification. With 2%
inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material :

38.15.2.2 RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising
and mixing 80% Gravel Soil and 20% Aggregates (30mm nominal size),
spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for
preparing the Base / Sub Base Layer (The Laboratory CBR of the gravel
cum 2349.00
soil shall not be less that 9%) including cost of all materials, labour, HOM
of Machineries complete as per specification. With 3%
inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material

38.15.2.3 RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising
and mixing 80% Gravel Soil and 20% Aggregates (30mm nominal size),
spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for
preparing the Base / Sub Base Layer (The Laboratory CBR of the gravel
cum 2936.00
soil shall not be less that 9%) including cost of all materials, labour, HOM
of Machineries complete as per specification. With 4%
inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material

38.15.2.4 RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising
and mixing 80% Gravel Soil and 20% Aggregates (30mm nominal size),
spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for
preparing the Base / Sub Base Layer (The Laboratory CBR of the gravel
cum 3520.00
soil shall not be less that 9%) including cost of all materials, labour, HOM
of Machineries complete as per specification. With 5%
inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material:

Page 200 of 375


38.15.3 RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material)
Pulverising and mixing coarse Aggregates (10mm & down size) and Fine
aggregate (2.36mm & down size) in 1:1 proportion, spreading with rotavator
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base / Sub
Base Layer including cost of all materials, labour, HOM of Machineries
complete as per specification.

38.15.3.1 RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material)
Pulverising and mixing coarse Aggregates (10mm & down size) and Fine
aggregate (2.36mm & down size) in 1:1 proportion, spreading with rotavator
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base / Sub
cum 2918.00
Base Layer including cost of all materials, labour, HOM of Machineries
complete as per specification. With 2% inorganic
Compound like RBI GRADE 81 by weight of Coarse & Fine Aggregate Mix
Material

38.15.3.2 RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material)
Pulverising and mixing coarse Aggregates (10mm & down size) and Fine
aggregate (2.36mm & down size) in 1:1 proportion, spreading with rotavator
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base / Sub cum 3717.00
Base Layer including cost of all materials, labour, HOM of Machineries
complete as per specification. With 3% inorganic
Compound like RBI GRADE 81 by weight of Coarse & Fine Aggregate Mix
Material

Page No. 282


38.15.3.3 RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material)
Pulverising and mixing coarse Aggregates (10mm & down size) and Fine
aggregate (2.36mm & down size) in 1:1 proportion, spreading with rotavator
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base / Sub cum 4498.00
Base Layer including cost of all materials, labour, HOM of Machineries
complete as per specification. With 4% inorganic Compound
like RBI GRADE 81 by weight of Coarse & Fine Aggregate Mix Material

38.15.4 RBI GRADE -81 - Cold In Place recycling Pulverising and


mixing the existing worn-out/ damaged road with recycler/milling machine
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base
including cost of all materials, labour, HOM of Machineries complete as per
specification. (RAP-Reclaimed Asphalt Pavement)

38.15.4.1 RBI GRADE -81 - Cold In Place recycling Pulverising and


mixing the existing worn-out/ damaged road with recycler/milling machine
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base cum 2467.00
including cost of all materials, labour, HOM of Machineries complete as per
specification. (RAP-Reclaimed Asphalt Pavement) With 2%
inorganic Compound like RBI GRADE 81 by weight of Milled Material:

Page 201 of 375


38.15.4.2 RBI GRADE -81 - Cold In Place recycling Pulverising and
mixing the existing worn-out/ damaged road with recycler/milling machine
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base
including cost of all materials, labour, HOM of Machineries complete as per
cum 3248.00
specification. (RAP-Reclaimed Asphalt Pavement) With 3%
inorganic Compound like RBI GRADE 81 by weight of Milled Material

38.15.4.3 RBI GRADE -81 - Cold In Place recycling Pulverising and


mixing the existing worn-out/ damaged road with recycler/milling machine
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base cum 4029.00
including cost of all materials, labour, HOM of Machineries complete as per
specification. (RAP-Reclaimed Asphalt Pavement) With 4%
inorganic Compound like RBI GRADE 81 by weight of Milled Material

38.15.4.4 RBI GRADE -81 - Cold In Place recycling Pulverising and


mixing the existing worn-out/ damaged road with recycler/milling machine
duly adding the specified quantity of inorganic Compound RBI GRADE-81
as specified by IRC: 37-2012, mixing thoroughly, sprinkling desired
quantity of water, grading with motor grader and compacting with vibratory
roller at OMC to the desired density for preparing the Stabilized Base cum 4810.00
including cost of all materials, labour, HOM of Machineries complete as per
specification. (RAP-Reclaimed Asphalt Pavement) With 5%
inorganic Compound like RBI GRADE 81 by weight of Milled Material:

38.16 RBI GRADE -81 --- Cutting the pothole to regular shape, trimming to
provide firm vertical faces, removing all loose materials, cleaning of surface,
filling with a mix of aggregates (40mm downsize) & local soil (except BC
Soil) in 1:1 proportion duly adding 2 % of Inorganic compound RBI Grade
81, mixing thoroughly, compacting & finishing etc., complete in WBM
layers for Pothole/Patch repairs.
Methodology and Construction :
Stabilization using RBI Grade 81 (the process of improving the cum 2640.00
engineering properties of a material by means of the addition of RBI
Grade 81) is subject to the quality of materials available and the impact of
the environment (traffic, climate, etc.) on the structural design. Stabilization
with RBI Grade 81 endeavors to increase the quality of the project and
reduce construction costs by improving the properties of substandard,
readily available material to comply with the relevant specifications.
1. Materials
Page No. 283
Soil or Gravel
38.17 Soilfix
Stabilizer Chemical
agent, RBIcompound
Grade 81 --- Cutting the pothole to regular shape,
trimming
Should be to provide
kept under firmcover vertical faces, from
and protected removing all from
moisture loose thematerials,
time of
cleaning
purchaseof to surface,
the timefillingof
with a mix
use. If of aggregates
material has(40mm
been downsize) & local
left exposed to
soil (except BC Soil) in 1:1 proportion duly adding 0.5
environmental elements, consult a RBI Grade 81 representative. It is% of Soilfix Chemical
compound, mixing thoroughly, compacting & finishing etc.,
preferable to stabilize a soil with a continuously smooth gradation curve complete in
cum 3136.00
WBMthe
from layers for Pothole/Patch
maximum particle sizerepairs.
to the smallest particle size with no excess
Ref:
or lackIRCinSPcertain
20 : 2002 : RURAL
particles. ThisROADS MANUAL
will ensure AND
better MORT&H capabilities
interlocking
SPECIFICATIONS
of the soil particlesFOR ROADin
resulting AND BRIDGE
increased WORKS
density and( 4TH
strength of the soil. It
REVISION
is recommended) that the soil material have sufficient fine material (< 2.00
mm) to effectively stabilize the material with RBI Grade 81.
2. Water Page No. 286
Water used should be free from harmful substances that may affect
the setting and hardening process of the stabilizer. Water that is thought to
encourage adverse reactions should be tested for compatibility with RBI
Grade 81.
3. Construction procedures
The stabilization of soil requires the careful programming of several
operations:
a. Pulverization, which may require initial scarifying
b. Addition of stabilizer
c. Thorough mixing of soil, stabilizer and added water
d. Laying, spreading and compacting
e.Curing - (minimum of 7 days curing is necessary)
Thus efficient planning of the side operations is necessary to minimize the
time between mixing and compacting. The periods of working should also
be consistent with the climatic conditions and the capability of the
construction equipment or plant, to keep to a minimum, if any changes in
moisture content and delays before compaction. Therefore moisture control
has to be considered throughout the stabilization process. A good indication
of the moisture content is to be found in the wheel tracks on the
uncompacted mixture. If too dry for satisfactory compaction, the material in
the tracks would crumble and crack; if too wet it wouldPagebe easily
202 of 375moulded,
deforming plastically. Close to the optimum moisture content the wheel
tracks would have a dense, stiff
surface. It is recommended that 8 – 12 tons smooth-wheeled rollers or 6 –
38.18 CLAY HOLLOW BRICKS (Extruded) Providing and
constructing thick clay hollow brick masonry in cement mortar 1:6 using
horizontal perforated clay hollow brick with minimum crushing strength of
35 kg/sqcm including scaffolding, curing etc., complete as directed at all
levels. STANDARDS
Minimum Crushing Strength 35 Kg/Sqcm.
U- Value 1.1 W/SqmK.
Density 695 Kg /Cum.
Water absorption <20 %.
Reduces the energy consumption and hence help to maintain
comfortable temperature inside.
Natural & Green Building Product.
*Ref: - IS 3952 Guidelines for use of horizontally perforated clay
bricks.
Construction Methodology
* All concrete surfaces of beams and columns coming in contact
with brick work is to be hacked.
* Pre wet the bricks before construction.
* Use cement mortar slurry of 1:2 on the hacked surface to create a
roughened surface for proper bonding.
* Use silt free (less than 5%) sieved clean sand for mortar.
* Place the marker course of brick (1st course) after checking the
vertical & horizontal alignment. And also mark the vertical course
up to beam bottom on the column to maintain the equal mortar
joints. * Mix mortar in
proportion of 1:6 for 200 & 150 mm thick walls and 1:4 for 100 mm thick
walls using Farma box (Equal to 1 cement bag) for measuring sand and a
measuring can to standardize quantum of water to get a consistent mix.
Mix well for uniformity. Mix mortar in small manageable quantities and use
it within ½ an hour.
* Mortar joints should be 10 to 12 mm for both vertical and horizontal
joints. The joints should be neatly pointed using an Aluminum Straight
edge.
* Give concrete band of 1:2:4 with 8 mm steel (2 Nos.) in a 100 mm thick
38.18.1 CLAY HOLLOW BRICKS (Extruded) -- of size 400 x 200 x 200mm
Providing and constructing thick clay hollow brick masonry in cement
mortar 1:6 using horizontal perforated clay hollow brick with minimum
crushing strength of 35 kg/sqcm including scaffolding, curing etc., Sqm 864.00
complete as directed at all levels.
_do_ of size 400 x 200 x 200mm

38.18.2 CLAY HOLLOW BRICKS (Extruded) -- of size 400 x 200 x1 50mm


Providing and constructing thick clay hollow brick masonry in cement
mortar 1:6 using horizontal perforated clay hollow brick with minimum
crushing strength of 35 kg/sqcm including scaffolding, curing etc., Sqm 677.00
complete as directed at all levels.
_do_ of size 400 x 200 x1 50mm

38.18.3 CLAY HOLLOW BRICKS (Extruded) -- of size 400 x 200 x 100mm


Providing and constructing thick clay hollow brick masonry in cement
mortar 1:6 using horizontal perforated clay hollow brick with minimum
crushing strength of 35 kg/sqcm including scaffolding, curing etc., Sqm 655.00
complete as directed at all levels.
_do_ of size 400 x 200 x 100mm

Page No. 287

Page 203 of 375


38.19 Dry Lean Concrete (DLC) for Profile correction of existing
bituminous road surface before carrying out White Topping
Dry Lean Concrete (DLC) M-5 for Profile correction of existing
bituminous road surface before carrying out White Topping Construction
of dry lean cement concrete sub base layer over existing scarified (to
the depth of 25 mm with miller machine includes mobilization, diesel
and operating cost, includes cleaning by air blower/sand blasting/
brooming etc.) bituminous road surface with coarse and fine aggregate
conforming to IS 383, the size of coarse aggregate not exceeding 25mm,
aggregate cement ratio not to exceed 15:1, aggregate gradation after
blending to be as per Table 600-1, cement content not less than 160
kg/cum, optimum moisture content to be determined during trial length
construction, concrete strength not to be less than 10 Mpa at 7 days,
mixed in ready mix concrete plant or a batching plant (to ensure
consistency) transported to site, laid to the depth of 40 mm - 50 mm cum 3401.00
with a fixed form paver with electric sensor, having gang mounted
vibrators equally spaced with variable rpm and atleast three integral
steel tubes with 8-10 tonnes vibratory rollers for screeding, levelling,
compaction, finishing and curing, includes lifting/shifting charges of
paver, as per specifications complete, ( cement 160kgs. coarse
aggregate= 0.86 cum, Fine aggregate=0.58cum)
MORTH specifications No.601.

38.20 WHITE TOPPING


38.20.1 Providing and laying White Topping as per IRC:SP76-2008 over
bituminous surface (Existing bituminous surface preparation to be done if
necessary either by milling or levelling course with BM/DBM to correct
surface profile and to be paid separately) with unreinforced M-40 grade
pavement quality concrete (PQC)using polymeric synthetic fibre as per
ASTM (1116) such as polyester / polyethylene / polypropylene at 1.20
kg/cum, mixed in batching and mixing plant or weigh batcher as per
approved mix design to achieve minimum flexural strength or modulus of
rupture of concrete 4.50 MPa at 28 days limiting maximum water cement
ratio to 0.40, transported to site, laid with mechanical paver finisher,
spread, vibrated, compacted and finished in a continuous operation to the
lines and grades as per drawing, texture finishing of surface, spraying two cum 5813.00
layers of curing compound, curing with water sprayed on hessian cloth
coverd over concrete surface, groove cutting to a depth of 1/3 of the slab
depth and of width 3-5 mm as per design (grove cutting to be paid
separately). For thin white topping and ultra thin white topping the groove
cutting shall be 1.25mm x 1.25m grid) including cost of all materal, side
from work, labour and HOM of machineries etc.
complete as per specifications.
- do - with unreinforced M40 grade pavement quality concrete using
43 grade OPC @ 420 kg/cum, coarse aggregate, fine aggregate and
admixture confirming to IS 9130-1999 (R-2004)

Page No. 290


38.20.2 Providing and laying White Topping as per IRC:SP76-2008 over
bituminous surface (Existing bituminous surface preparation to be done if
necessary either by milling or levelling course with BM/DBM to correct
surface profile and to be paid separately) with unreinforced M-40 grade
pavement quality concrete (PQC) using polymeric synthetic fibre as per
ASTM (1116) such as polyester / polyethylene / polypropylene at 1.20
kg/cum, mixed in batching and mixing plant or weigh batcher as per
approved mix design to achieve minimum flexural strength or modulus of
rupture of concrete 4.50 MPa at 28 days limiting maximum water cement
ratio to 0.40, transported to site, laid with mechanical paver finisher,
spread, vibrated, compacted and finished in a continuous operation to the
lines and grades as per drawing, texture finishing of surface, spraying two cum 5615.00
layers of curing compound, curing with water sprayed on hessian cloth
coverd over concrete surface, groove cutting to a depth of 1/3 of the slab
depth and of width 3-5 mm as per design(grove cutting to be paid
separately). For thin white topping and ultra thin white topping the groove
cutting shall be 1.25mm x 1.25m grid) including cost of all materal, side
from work, labour and HOM of machineries etc. complete as per
specifications.
- do - with un-reinforced M-40 grade Pavement Quality Concrete (PQC)
using 53 grade OPC at 315 kg/cum and cementitious material ground
granulated blast furnace slag at 105 kg/cum, satisfying IS:12089-
1987(R2004) coarse aggregate fine aggregate, admixture conforming

Page 204 of 375


38.20.3 Providing and laying White Topping as per IRC:SP76-2008 over
bituminous surface (Existing bituminous surface preparation to be done if
necessary either by milling or levelling course with BM/DBM to correct
surface profile and to be paid separately) with unreinforced M-40 grade
pavement quality concrete (PQC)using polymeric synthetic fibre as per
ASTM (1116) such as polyester / polyethylene / polypropylene at
1.20kg/cum, mixed in batching and mixing plant or weigh batcher as per
approved mix design to achieve minimum flexural strength or modulus of
rupture of concrete 4.50 MPa at 28 days limiting maximum water cement
ratio to 0.40, transported to site, laid with mechanical paver finisher,
spread, vibrated, compacted and finished in a continuous operation to the
lines and grades as per drawing, texture finishing of surface, spraying two cum 5444.00
layers of curing compound, curing with water sprayed on hessian cloth
coverd over concrete surface, groove cutting to a depth of 1/3 of the slab
depth and of width 3-5 mm as per design (grove cutting to be paid
separately). For Thin white Topping and ultra thin white topping the groove
cutting shall be 1.25mm x 1.25m grid) including cost of all materal, side
from work, labour and HOM of machineries etc. complete as per
specifications.
- do - with un-reinforced M-40 grade pavement quality concrete (PQC)
using 53 grade OPC at 357 kg/cum and cementitious material fly ash,
at 63 kg/cum, satisfying IS:3812-2013(Part-1) coarse aggregate fine
aggregate, admixture conforming to IS:9103-1999(R2008)
38.21 Providing groove cutting for width of 4mm - 6mm and 1/3rd depth of
PQC Whitetopping within 8-10 hrs of placing/finishing of PQC including
cost of cutting machine, generators, HOM of machinery, blades, coolant
etc., including cleaning of groove and providing sand and hot bituminous or
equivalent approved sealant filling etc., including cost of conveyance of all
materials, labour, lead and lift charges and all other incidental charges as
per drawing and as per specifications.Cement Concrete White
Topping/Concrete Overlay as per IRC: SP: 76-2008 White topping is defined
as a PCC (Portland Cement Concrete) overlay constructed on the top of an
existing bituminous pavement. Thus, it is a rehabilitation or structural
strengthening alternative on bituminous pavement. Rutting of pavement is
a real problem in a country like India,
with heavy truck loads, operating under frequent start/stop conditions. It is
commonly applied where rutting of bituminous pavements is a recurring
problem, particularly in case of city roads. Concrete over lays offers the m 92.00
potential for extended service life, increased structural capacity, reduced
maintenance requirements and lower life-cycle costs when compared with
bituminous overlay alternative Concrete overlays have been used on both
bituminous (flexible) pavements since 1918 and existing concrete pavement
since 1913.White topping is classified into three types, based on the
thickness of overlay, types of interface provided i.e., degree of bonding
between the underlying bituminous layers with PCC overlay & thickness of
overlay. They are:
i) Conventional White topping – which consists of PCC overlay of thickness
200 mm or more, which is designed & constructed without consideration of
any bond between existing overlay & underlying bituminous layer (without
assuming any composite action). ii) Thin White topping (TWT) – which has
PCC overlay between 100 – 200 mm. It is designed either considering bond
between overlay & underlying bituminous layer or without consideration of
bond. High strength concrete (M 40 or
Page No.higher)
291 is normally used to take care
38.22 Use of GEO Textiles / GEO fabrics in road pavements and subsurface
drainage works.
Providing and Inserting Prefabricated Vertical Drain, core with synthetic
material and wrapped with Non-woven geotextile 120GSM in very soft clay
for quick consolidation.
Ref: IRC SP 59 : GUIDELINES FOR USE OF GEO TEXTILES IN ROAD
PAVEMENT S AND ASSOCIATED WORKS- 2002
Technical Data;
-do- with 100mm width ,thickness = 4mm,mass per linear meter
90g/m,with tensile strength =2.0 KN
-do –with 100mm width,thickness =5.2 mm,mass per linear meter
110g/m,with tensile strength = 2.4 KN m 73.00
Application Methodology;
Vertical drains may be installed employing either vibratory or static
methods. In either case, the drain is enclosed in a tubular steel mandrel of
small cross-sectional area usually 50x125mm. A small steel anchor plate is
attached to the drain at the bottom of the mandrel. The mandrel is then
driven in to the soil either with a static or vibratory rig. When the design
depth is reached, the mandrel is extracted. The anchor plate retains the
drain in the soil. When the mandrel is fully extracted the drain is cut off a
new anchor plate is installed and the process begins again. These are used
in Land reclamation projects, Construction of highways ,railways ,airfields
and dykes,Ports and harbor construction, Development of industrial
sites ,Mitigation of liquefaction,etc..

Page 205 of 375


38.23 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres on
the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing.
Technical Data :
_ do_with GSM 150,1.3mm thickness,Grabtensile
strength 540N, Puncture strength 315N,Trapezoidal tear 230N,Apparent
opening size 180 μm,
_do_200Gsm,1.6 mm thickness,Grabtensile strength 720N,Puncture
strength 400N,Trapezoidal tear 300N,Apparent opening size 150μm
_do_250Gsm,1.8 mm thickness, Grabtensile strength
865N,Puncture strength 525N,Trapezoidal tear 360N,Apparent opening size
150μm _do_300Gsm,1.9 mm thickness,
Grabtensile strength 1010N,Puncture strength 650N,Trapezoidal tear 415N,
Apparent opening size 120μm
_do_400GSM,2.5 mm thickness, Grabtensile strength1325N,Puncture
38.23.1 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres
on the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing.
-do-with GSM 150,1.3mm thickness,Grabtensile strength 540N, Puncture Sqm 91.00
strength 315N,Trapezoidal tear 230N,Apparent opening size 180 μm,

38.23.2 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres
on the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing.
-do- GSM200G,1.6 mm thickness,Grabtensile strength 720N,Puncture Sqm 94.00
strength 400N,Trapezoidal tear 300N,Apparent opening size 150μm

38.23.3 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres
on the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing.
-do-GSM 250,1.8 mm thickness, Grabtensile strength 865N,Puncture Sqm 95.00
strength 525N,Trapezoidal tear 360N,Apparent opening size 150μm

38.23.4 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres
on the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing. Sqm 103.00
-do- GSM 300,1.9 mm thickness, Grabtensile
strength 1010N,Puncture strength 650N,Trapezoidal tear 415N, Apparent
opening size 120μm

38.23.5 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres
on the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing.
-do-400 GSM,2.5 mm thickness, Grabtensile strength1325N,Puncture Sqm 109.00
strength 785N,Trapezoidal tear 510N, Apparent opening size 106μm

38.23.6 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres
on the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing.
-do- 500GSM ,2.9 mm thickness, Grabtensile strength1570N,Puncture Sqm 110.00
strength 910N,Trapezoidal tear 600N, Apparent opening size 90μm

38.23.7 Providing and Laying Needle punched and mechanically bonded Nonwoven
Geotextile indigenously manufactured from high quality synthetic fibres
on the prepared subgrade for separator cum filtration cum drainage
application with necessary overlaps as per drawing. sqm 136.00
-600GSM,3.4 mm thickness, Grabtensile strength1980KN,Puncture
strength 1080N, Trapezoidal tear 705N, Apparent opening size =70μm

Page No. 293

Page 206 of 375


38.24 Providing and Laying rope Gabions, indigenously manufactured from high
strength rope for slope protection and erosion control for river bank and
sea-shore protection. Exclusive of providing & filling stones.
Technical Data;
do - size 1M x1M x 1M, aperture 150mm x 150mm, Tensile strenth
9500Kg/m, Punching shear strenth 5200Kg
-do - size 1M x1M x 2M, aperture 100mm x 100mm, Tensile strenth
14000Kg/m, Punching shear strenth 6200Kg
-do-size 1M x1M x 3M, aperture 100mm x 100mm, Tensile strenth
14000Kg/m, Punching shear strenth 6200Kg,
Application Methodology;
Copper and polymer Gabions are rectangular or cylindrical baskets
fabricated from polymer meshes and usually filled with stone and used for
structural purposes such as retaining walls, revetments, slope
protection,and similar applications. These are fabricated from ropes of
suitable diameter into a box like form with required size and apertures.
These are used in application like River bank protection, revetment, toe-
walls,aprons,groynes,spurs,channel linings, sea shore protection, seawalls,
Anti-erosion structures,etc.

38.24.1 _do_ copper and synthetic rope gabion of size 1mx1mx1m, aperture
Box 1160.00
100mm x 100mm
38.24.2 _do_ copper and synthetic rope gabion of size 1mx1mx2m, aperture
Box 2142.00
100mm x 100mm
38.24.3 _do_ copper and synthetic rope gabion of size 1mx1mx3m, aperture
Box 3214.00
100mm x 100mm
Page No. 294
38.25 Providing and Synthetic Biaxial Geogrid indigenously manufactured from
selected high tenacity synthetic yarn with high molecular weight (> 25000
g/mol), and low carboxyl end group (<30mmol/kg) for soil reinforcement
application for stabilisation, requirement of geogrid strength in both
direction with granular fill.
Technical Data;
-do- ultimate tensile strenth 30Kn/m in MD and CMD, Tensile strenth at
2% elongation 6Kn/m in MD and 6Kn/m in CD, aperture size in MD and
CD 26X26mm.
-do- ultimate tensile strenth 40Kn/m in MD and CMD, Tensile strenth at
2% elongation 7.5Kn/m in MD and 7.5Kn/m in CD, aperture size in MD
and CD 25X25mm
-do- ultimate tensile strenth 60Kn/m in MD and CMD, Tensile strenth at
2% elongation 9Kn/m in MD and 7.5Kn/m in CD, aperture size in MD and
CD 25X25mm
-do- ultimate tensile strenth 90Kn/m in MD and CMD, Tensile strenth at
2% elongation 11Kn/m in MD and 9Kn/m in CD, aperture size in MD and
CD 23X23mm
Application Methodology;
Biaxial geogrids are designed for applications where strength
requirement is in both directions. They are used in reinforcement of
granular roadbase and subbase, area stabilization, trackbed
stabilization, load transfer platforms,etc.

38.25.1 _do_ with 30 x 30 Kn/m Ultimate Tensile Strength Sqm 112.00


38.25.2 _do_ with 40 x 40 Kn/m Ultimate Tensile Strength Sqm 129.00
38.25.3 _do_ with 60 x 60 Kn/m Ultimate Tensile Strength Sqm 160.00
38.25.4 _do_ with 90 x 90 Kn/m Ultimate Tensile Strength Sqm 196.00
Page No. 295

Page 207 of 375


38.26 Providing and Synthetic Uniaxial Geogrid, indigenously manufactured
from selected high tenacity synthetic yarn with high molecular weight (>
25000 g/mol), and low carboxyl end group (<30mmol/kg) for reinforced soil
wall and slope application with granular fill as per design prepared by
technology provider of reinforced earth wall and slope.
Technical Data:
-do- with ultimate tensile strenth 40Kn/m in MD and 20Kn/m in CMD,
aperture size in MD and CD 30X25mm,
-do- with ultimate tensile strenth 60Kn/m in MD and 20Kn/m in CMD,
aperture size in MD and CD 30X25mm,
-do-with ultimate tensile strenth 80Kn/m in MD and 30Kn/m in CMD,
aperture size in MD and CD 30X25mm,
-do- with ultimate tensile strenth 100Kn/m in MD and 30Kn/m in CMD,
aperture size in MD and CD 30X23mm,
-do- with ultimate tensile strenth 120Kn/m in MD and 30Kn/m in CMD,
aperture size in MD and CD 30X23mm,
-do- with ultimate tensile strenth 150Kn/m in MD and 30Kn/m in CMD,
aperture size in MD and CD 30X23mm,
-do-with ultimate tensile strenth 200Kn/m in MD and 30Kn/m in CMD,
aperture size in MD and CD 30X22mm,
-do- with ultimate tensile strenth 250Kn/m in MD and 30Kn/m in CMD,
aperture size in MD and CD 30X20mm,
-do-with ultimate tensile strenth 35Kn/m in MD and 60Kn/m in CMD,
Tensile strenth at 2% elongation 8Kn/m in MD and 9Kn/m in CD, aperture
size in MD and CD 25X25mm
-do-with ultimate tensile strenth 40Kn/m in MD and 80Kn/m in CMD,
Tensile strenth at 2% elongation 8Kn/m in MD and 12Kn/m in CD,
Application Methodology:
Uniaxial geogrids are available in a range of tensile strength and are
suitable for applications, which require strength in one direction, these are
used in reinforced soil walls,steep slopes and basal reinforcement of Sqm 100.00
38.26.1 _do_ with 40 Kn/m Ultimate Tensile Strength
38.26.2 _do_ with 60 Kn/m Ultimate Tensile Strength Sqm 120.00
38.26.3 _do_ with 80 Kn/m Ultimate Tensile Strength Sqm 138.00
38.26.4 _do_ with 100 Kn/m Ultimate Tensile Strength Sqm 160.00
38.26.5 _do_ with 120 Kn/m Ultimate Tensile Strength Sqm 183.00
38.26.6 _do_ with 150 Kn/m Ultimate Tensile Strength Sqm 205.00
38.26.7 _do_ with 200 Kn/m Ultimate Tensile Strength Sqm 258.00
38.26.8 _do_ with 250 Kn/m Ultimate Tensile Strength Sqm 294.00
Page No. 296
38.27 Paving Fabric
Providing and Laying Needle punched and mechanically bonded Nonwoven
Paving Fabric indigenously manufactured from high quality Synthetic
staple fibres having grab tensile strength of 39Kg , and melting point of 150
°C confirming to ASTM / Morth sec - 700 over a tack coat of paving grade
bitumen 80-100 preparation, laid at the rate of 1 kg per sq.mtr over
thoroughly cleaned and repaired surface to surface with pneumatic roller to
maximize paving fabric contact with pavement surface as per drawing.
Application Methodology:
Paving fabric is a strong layer of fabric is applied under asphalt to
minimize surface water infiltration and prevent existing cracks in the Sqm 125.00
road from surfacing to enhance the performance of pavement. The
Barrier function refers to the prevention of fluid movement across theplane
of the geotextile. A nonwoven geotextile provides a barrier function when
saturated with an impermeable material, like bitumen. It Retards the
propagation of cracks, Reduced the required design overlay thickness,
Extends the life of the overlay and the pavement section,These can be used
as asphalt over lay on flexible pavement a nd rigid pavement –a layer of
DBM/BC should be provided on rigid pavement before laying the paving
fabric.

Page No. 297

Page 208 of 375


38.28 Providing and construction of steel wire mesh Gabion retaining wall for
retaining walls with Mechanically woven double twisted, mechanically
selvedge, Zinc+PVC coated gabion of mesh type 10x2, wire dia 2.7/3.7mm
(inner/outer diameter), selvedge wire dia 3.4/4.4mm as per standards
(EN/IS 16014) with diapragms (partitions), in every 1M for Gabions of
length higher then 1.5M as per standards, from manufacturers of proven
experience in similar technology, including filling of rubble of size 150mm
to 250mm at site including packing compactness to lins and levels in the
exposed face of masonry, in dry condition, simultaneously during the
course as per construction guidelines by the department/installtion
guideline manufacturer, including all lead, lift and labour etc complete. (In
case of under water installation, the approrite provision for crane, extra
labour etc., need to be taken extra).
Application Methodology:
Metal Gabion is comprised double twisted hexagonally woven steel wire
mesh with zinc galvanized and PVC coated compartmented baskets with a
rectangular box shape. The compartments are of equal dimensionand are
formed by internal diaphragms. The compartment is filled with natural
stone at the site of use,to form flexible, permeable, monolithic structures for
earth retension and the diaphragms assure minimum stone migration
within the basket. Thus providing even distribution of the stone even in
abnormal conditions,and adding strength to the container to help retain its cum 2589.00
38.28.1 _do- for Gabion box size of 1x1x1
38.28.2 _do- for Gabion box size of 1.5x1x1 cum 2276.00
38.28.3 _do- for Gabion box size of 2x1x1/1 diaphragm cum 2366.00
38.28.4 _do- for Gabion box size of 3x1x1/2 diaphragm cum 2187.00
38.28.5 _do- for Gabion box size of 4x1x1/3 diaphragm cum 2142.00
38.28.6 _do- for Gabion box size of 1x1x0.5 cum 3750.00
38.28.7 _do- for Gabion box size of 1.5x1x0.5 cum 3258.00
38.28.8 _do- for Gabion box size of 2x1x0.5/1 diaphragm cum 3303.00
38.28.9 _do- for Gabion box size of 3x1x0.5/2 diaphragm cum 3214.00
38.28.10 _do- for Gabion box size of 4x1x0.5/3 diaphragm cum 3125.00
Page No. 298
38.29 BORE PACKING for pipe joints
Providing & applying high strength non shrink free flow grout (confirming to
BS 1881-Part 116 : 1983)comprising of blend of portland cement, graded
fillars and chemical additives which impart controlled expansion in the
plastic state duly minimizing water demand. (Minimum 25mm thickness
around the pipe)
Standards
1. Compressive strength for 28 days 78 N/sqmm
2. Flowable (Water powder ratio 0.18)
3. Pourable (Water powder ratio 0.165)
4. Tensile strength for 28 days 3.5 N/ sqmm
5. Flexural strength for 28 days 10 N/ sqmm No 295.00
6. Unrestrained expansion – 2 to 4 % in the plastic state
Methodology :
Non shrink free flow grout shall be added to the water in the ratio of 25 Kg :
4.125 ltrs of water for pourable condition and for flowable condition 4.5 ltrs
by using heavy duty slow speed grill (400 to 500 RPM) fitted with the
suitable peddle for 5 minutes. To get the best result the mixed grout should
be placed and used in 20 minutes after the mixture.

38.30 PROVIDING TRAPEZOIDAL PROFILED SHEET


Providing and installing of pre painted Galvolume iron Trapezoidal
profiled sheet of approved make 1060 mm width (1000 mm cover width),
28-30 mm crest height with crest distance of 200 mm c/c with 2 ribs at the
centre for stiffening. The total coated thickness (TCT) of the sheet will be
0.47 mm +/- 0.02 mm tolerance Zinc-Alu Alloy coating AZ150 gsm as per
ASTM 1397/A755-550 mpa steel grade, 5-7 microns epoxy primer on both
Sqm 688.00
side of the sheet and polyester top coat 20-22 microns using self
drilling/self tapping screws of 25 mm length, to be fixed over the existing
purlins, rafters, channels and trusses.

Page No. 299


38.31 Providing and installing of approved make pre painted Galvalume iron
Accessories, like, plain, ridges, plain gutter, plain flashing, corner Trim, etc.
The total coated thickness (TCT) of the sheet shall be 0.47 mm +/- 0.02
tolerance mm Zinc-Alu Alloy coating AZ 150 gsm as per ASTM 1397/755 -
550 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet
Sqm 660.00
and polyester top coat 20-22 microns using self drilling / self tapping
screws of 25 mm length. (width upto 500-600 mm only), to be fixed over the
existing purlins, rafters, channels and trusses.

Page 209 of 375


Page No. 301
38.33 Stone Cleaning _ Cleaning Unpolished granite surface by application of
Proven, Readily Biodegradable, VOC free, Stabilised, Non-Dilutable, Water
Base & Ready to Use (RTU) liquid chemical formulation with no contact
time restriction over the heavily soiled unpolished granite stone surface
using a 30 psi spraying equipment / Roller / Brush spreading & thoroughly
wetting the chemical @ minimum 0.25 ltr to cover 1 sq.mtr on the surface
to be treated. Allow the penetration & chemical reaction time for a
minimum of 24 hrs time. The surface is then low pressure water rinsed
with rotary nozzle @ 700 psi after scrubbing the surface till all the organic
& inorganic contamination, dirt, hydro-carbon soils, algae & rust stains
from both the surface & pore of the substrate is completely removed, the
stone is returned to its natural colour & permeability restored. The
formulation being used should be free from corrosive acids such as
Hydrochloric or Muriatic acid, Hydrofluoric acid, caustics or Sodium
Hydroxide, bleach or Sodium Hypochlorite, abrasives and petroleum
distillates. No free Acids or Alkalis to be used.The process should include
all chemical materials, labour, application tools, spraying equipment, Low
pressure washer, safety procedures, hand gloves, face shields, goggles,
protective wear clothing, scaffolding & working platform, lead & lift,
transportation, all incidental charges etc., complete as per the directions of
38.33.1 the Engineer-in-charge
Stone of the work. liquid solution
cleaning using biodegradable
Cleaning granite surface by using aproved quality bio-degradable liquid
solution (Ammonium Hydrogendifloride solution) as per the directions of
Engineer incharge of the works. The cost of works includes cost of
materials, HOM of machineries, labour charges etc. complete.
Methodology :
1) The solution to be used shall be free from hydrofloric acid, muriatic acid,
caustic, bleach, abrasive or petroleum distillates and the neutral pH should
be 5.0 to 5.5.
2) The surface is to be washed first with water pressure of 130psi/ Sqm 364.00
sec, until the deposit of dirt, hydro carbon soils and algae from the
surface and the pores of the surface are completely removed.
3) Cleaned surface to be dried for 24 hours.
4) Bio-degradable solution shall be applied over the dry surface.
5) All safety measures shall be taken during the process of application.

Page No. 303


38.34 SLIDING WINDOWS (2 shutters) or equivalent sliding Windows (suitable
for residential and non-residential buildings) Providing and fixing of Sliding
Windows made of Galvanized Steel (BaseSteel as per IS 513, D quality,
galvanized as per IS 277 with Zinc of 120 GSM). The factory made section
should be powder coated with Pure polyester powder upto 50-60 microns
thick with total coated thickness of 0.8 mm for Outer Frame and 0.58mm
thickness for Sliding Shutter Section. The Outer Frame size for Two Tracks
with Grill provision is 90mm x 50mm and without grill provision is of
75mm x 50 mm. The Window Shutter section is of 58 mm x 36 mm. The
Outer Frame should have Two integrated Guide tracks of 12mm width and
24mm deep for provision to slide the Shutter / sash frame and facilitates
with a water drain outlet component made of PVC. The Shutter frame
should be fitted with 5mm thick plain float glass of reputed make and fixed
with EPDM weathering seal resistant accessories and handle made of
Alumimium 1 No. per each shutter. The sections are to be cut to length
miter joined with corner brackets. The total window system is to be
installed at the site using anchor fasteners, Silicon sealant applied at the
Outer Frame Corners. The cost is inclusive of conveyance of all materials
accessories, labour charges, and erection at site with complete finished
38.34.1 Window with Two Sliding Shutters and with Grill Outer Frame Size 90 mm
x 50 mm have a rebate of 15mm x 5 mm to fit grill made of 10mm MS Sq
Rods for horizontal bars welded at a regular pitch of 150mm to 12mm x 6 Sqm 5164.00
mm MS flat.

Page 210 of 375


38.35 SLIDING WINDOWS (3 shutters) or equivalent sliding Windows (suitable
for residential and non-residential buildings):Providing and fixing of Sliding
Windows made of Galvanized Steel (Base Steel as per IS 513, D quality,
galvanized as per IS 277 with Zinc of 120 GSM). The factory made section
should be powder coated with pure polyester powder upto 50-60 microns
thick with total coated thickness of 0.8 mm for Outer Frame and 0.58mm
thickness for Sliding Shutter Section. The Outer Frame size for Two Tracks
with Grill provision is 135mm x 50mm. The Window Shutter section is of 58
mm x 36 mm. The Outer Frame should have Two integrated Guide tracks of
12mm width and 24mm deep for provision to slide the Shutter / sash frame
and facilitates with a water drain outlet component made of PVC. The
Shutter frame should be fitted with 5mm thick plain float glass of reputed
make and fixed with EPDM weathering seal resistant accessories and
handle made of Alumimium 1 No. per each shutter. The sections are to be
cut to length miter joined with corner brackets. The total window system is
to be installed at the site using anchor fasteners, Silicon sealant applied at
the Outer Frame Corners. The cost is inclusive of conveyance of all
materials accessories, labour charges, and erection at site with complete
finished item of work

38.35.1 i) Center Shutter Fixed: center shutter frame made of section with size
36mm x 58mm should be fitted with 5mm thick plain float glass of reputed
make, EPDM gasket all around the glass and fixed to the Outer Frame with
the supporting section of size 29mm x 20mm of 0.58mm thick fixed Sqm 5698.00
horizontally on top and bottom of the shutter frame

38.35.2 ii) Center Shutter Sliding: center shutter frame made of section of
size36mm x 58mm should be fitted with 5 mm thick plain float glass of
reputed make. The supporting guide section of size 15mm x 19mm of
0.58mm thick fixed horizontally at top and bottom of shutter frame and Sqm 5768.00
slides along the bottom and top guide tracks made of sections size 24mm x
20mm of 0.58mm thick and 29mm x 20mm of 0.58mm thick.

Page No. 304


38.36 Steel Windows with grill and flymesh for residential buildings vProviding
and fixing of windows made of pre-painted steel (base steelas per IS 513 of
0.58mm tick galvanized as per IS 277 with zinc of 120GSM). Primer coated
with epoxy primer of 5-7 microns thick, finishpainted with a polyester paint
of 12-16 microns thick and back coatedwith 5-7microns thick alkyd backer.
Section for outer frame should beof 72x55mm, centre mullion should be of
72x50mm, section of the fixed glass beading should be of 12x12mm. and
section of the shutter shouldbe of 48x25mm. Outer frame and mullion
sections to have rebate forglazed shutters, fly mesh and 20mm provision for
guard bars/grill flymesh shutters section should be of 20x40mm. The
sections are to becut to length mitre joined with corner bracket. Centre
mullion is to befixed with mullion cap. Handle latch 2 Nos of heavy duty
stainless steelpivot hinges shall be provided for shutter. The window should
be ledwith 50mm thick plain float glass and S.S. Mesh for fly mesh
shutter(304 grade). Rubber gaskets are to be provided all around the glass.
The above frames should be fixed to the concrete/masonry wall bymeans of
self-expanding screws, including 10mm square guard barswith 6”
(152.4mm) pitch complete for finished item of work.

38.36.1 Double shutter window with vertical mullion 3’0”x4’0” (914.4mm


x1219.2mm) outer frame section size of 72x50mm shutter frame section Sqm 6492.00
size of 48x25mm mullion section size of 72x50mm.
38.36.2 Centre fixed both side openable shutter window 5’0”x4’0” (1524mm x
1219.2mm). Outer frame section size of 72x50mm. Shutter frame section
size of 48x25mm mullion section size of 72x50mm. Fixed beading section Sqm 6270.00
size of 12x12mm

Page 211 of 375


38.37 Steel Windows with grill for residential buildings Providing and fixing of
windows made of pre-painted steel (base steel as per IS 513 of 0.58mm tick
galvanized as per IS 277 with zinc of 120GSM). Primer coated with epoxy
primer of 5-7 microns thick, finish painted with a polyester paint of 12-16
microns thick and back coated with 5-7microns thick alkyd backer. Section
for outer frame should be of 48x50mm, centre mullion should be of
48x50mm, section for shutter should be of 48x25mm and fixed glass
beading section should be of 12x12mm. Outer frame and mullions to have
rebate for glazed shutter and a 20mm provision for guard bars/grills. The
sections are to be cut to length mitre joined with corner bracket. Centre
mullion is to be fixed with mullion cap. Handle stay 2Nos of stainless steel
heavy duty pivot hinges shall be provided for shutter. The window should
be panelled with 5mm thick plain float glass. Rubber gaskets are to be
provided all around the glass. The above frames should be fixed to the
concrete/ masonry wall by means of self expanding screws, including
10mm square guard bars with 6” (152.4mm) pitch etc., complete for
finished item of work.

38.37.1 Double shutter window with vertical mullion 3’0”x4’0” (914.4mm


x1219.2mm) outer frame section size of 48x50mm shutter frame section Sqm 3758.00
size of 48x25mm mullion section size of 48x50mm.
Page No. 305
38.37.2 Centre fixed both side openable shutter window 6’0”x4’0”
(1828.8mmx1219.2mm). Outer frame section size of 48x50mm shutter
frame section size of 48x25mm mullion section size of 48x50mm. Fixed Sqm 4102.00
beading section size of 12x12mm.
38.38 Pre-painted steel windows / ventilators & door frames: Supply and
fixing of windows and top hung and fixed louered ventilatorsmade of pre-
painted steel (base steel as per IS 513 of -0.58mm thick‘D’ quality,
galvanized as per IS 277 with zinc of 120 GSM) with apolyester paint, of 12-
16 microns thick and back coated with 5-7 micronsthick alkyd backer.
Section for outer frame should be 46x52mm, sectionfor shutter should be
46x46mm, section for mullion should be 46x70mm,and section for beading
should be 18x25mm and section for louvered ventilator should be
33x57mm the windows hould be pannaled with 5 mm thick plain float glass
and 4mm pinhead glass for ventilators with rubber Gasket. The sections
are to be cut to length, mitre joined with corner bracket and centre
mullions are to be fixed using mullion cap. Handle made of high grade
aluminium powder coated and nylon receiver. Corner brackets made of
CRCA with Zinc Phosphate. Mullion caps made of glass filled nylon. The
above frames should be ixed to the concrete/ masonry will by means of self-
expanding screws. Including 10mm square bars with 6” pitch complete
finished item of work.

38.38.1 WINDOWS : Double shutter 3’-0” X 4’ - 0” (914.4MM x 1219.2 MM) outer


frame section size of 46x52mm shutter frame section size of 46x46mm. Sqm 3842.00

38.38.2 WINDOWS : Centre fixed both side openable shutter 5’-0” x 4’-0”
(1524x1219.2mm) outer frame section size of 46x52mm shutter frame
section size of 46x48mm mullion section size of 46x70mm fixed beading Sqm 3596.00
section size of 18x25mm.
38.38.3 Ventilators : Top hung 4’-0” x 3’-0” (1219.2x914.4mm) outer frame section
size of 46x52mm shutter frame section size of 46x46mm mullion section Sqm 3616.00
size of 46x70mm.
38.38.4 Ventilators : Fixed lovers 4’-0” x 3’-0” (1219.2x914.4mm) (Box section)
Sqm 3482.00
outer frame section size of 33x57mm mullion section.
38.39 Road Humps / speed breakers for control of vehicular speeds on roads
Providing road humps for the entire formation width, using bituminous
premix materials and heavy duty cobble stones 60 mm thick, having road
hump dimension of 1.00 mtr. (width) X 0.15 mtr (height) rectangular
sections and ramp on either side of road hump of 0.85 mtr (wide), including
providing WBM (2 layers) for shoulder portion 1.7mts in length on either
side, completing with road marking paint with applied thermoplastic
compound with reflecting glass beeds on bituminous surface and providing
2 Nos. retro reflective traffic signs as per IRC SP 67 -2010 (for details refer
IRC 99-1988)

38.39.1 For single lane for formation width of 7.50mtrs. and using SDBC mix
Unit 33005.00
meterial.
38.39.2 For Intermediate lane for formation width of 9.00mtrs using SDBC mix
Unit 39017.00
material.
Page No. 306
38.39.3 For 2 lane for formation width of 12mtrs. using SDBC mix material. Unit 50370.00

Page 212 of 375


38.40 Providing road humps for the entire formation width, using bituminous
premix materials and heavy duty cobble stones 60 mm thick, having road
hump dimension of 1.00 mtr. (width) X 0.15 mtr (height) rectangular
sections and ramp on either side of road hump of 0.85 mtr (wide), including
providing WBM (2 layers) for shoulder portion 1.7mts in length on either
side, completing with road marking paint with applied thermoplastic
compound with reflecting glass beeds on bituminous surface and providing
2 Nos. retro reflective traffic signs as per IRC SP 67 -2010 (for details refer
IRC 99-1988)

38.40.1 For single lane for formation width of 7.50mtrs. and using BC mix
Unit 36376.00
meterial.
38.40.2 Intermediate lane for formation width of 9.00mtrs using BC mix material.
Unit 40385.00

38.40.3 2 lane for formation width of 12mtrs. using BC mix material. Unit 52191.00
38.41 Providing, laying, rumble strips, 250 mm wide and 25mm height in
rectangular shape at 1.00 mtr center to center for the entire formation
width of road using pre mix bituminous material, including providing WBM
(2 layers) for shoulder portions, applying tack coat, providing 2 Nos. retro
reflective traffic signs as per IRC SP 67-2010 (for details IRC 99-1988)

38.41.1 For 3 nos - including Wbm layers for length of 2 mtrs on either side of
carriage way in shouldr portion.
38.41.1.1 Single lane using SDBC mix material Unit 18580.00
38.41.1.2 Intermediate lane using SDBC mix material. Unit 18132.00
38.41.1.3 2 lane using SDBC mix material. Unit 22847.00
38.41.2 For 5 nos - including Wbm layers for length of 4 mtrs on either side of
carriage way in shouldr portion.
38.41.2.1 Single lane using SDBC mix material Unit 26422.00
38.41.2.2 Intermediate lane using SDBC mix material. Unit 21948.00
38.41.2.3 2 lane using SDBC mix material. Unit 33474.00
38.41.3 For 10 nos - including Wbm layers for length of 9mtrs on either side of
carriage way in shouldr portion.
38.41.3.1 Single lane using SDBC mix material Unit 45942.00
38.41.3.2 Intermediate lane using SDBC mix material. Unit 44396.00
38.41.3.3 2 lane using SDBC mix material. Unit 60040.00
38.41.4 For 15 nos - including Wbm layers for length of 15 mtrs on either side of
carriage way in shouldr portion.
38.41.4.1 Single lane using SDBC mix material Unit 65436.00
38.41.4.2 Intermediate lane using SDBC mix material. Unit 63103.00
38.41.4.3 2 lane using SDBC mix material. Unit 86567.00
Page No. 307
38.42 Providing and laying Geocells ultrasonically welded 1.30mm thick, HDPE
strips, expandable to form GEOCELLS of honeycomb structure, anchoring
to metal pegs at each and cell to be laid on prepared surface.

38.42.1 - do - 100mm height Sqm 362.00


38.42.2 - do - 150mm height Sqm 471.00
38.43 Providing, fabricating and fixing profiled poly erethane insulated roof of
1,06m width and 7,60m length sheets roof having external sheet of 0.5mm
steel with powder coated finish, bottom sheet of 0.4mm steel with powder
coated finish. The roofing system shall have water proof over lapping
arrangement at the inter section of two sheets the fasting shall be of self
Sqm 2008.00
tapping screws dia 6.3mm or required length with PVC head along with
washer pre-painted aluminium cap unit with build in seal arrangements.
The entire roof shall be firmly fasteed to the existing frame

38.44 uPvC Windows and Doors


38.44.1 Providing & fixing of glazed 2 Track-2 Panel Sliding Windows made out of
multi Chamered uPVC sections with TPV gaskets having Isolated drainage
and reinforced witgh Galvanized iron profiles through out the window. The
outer frame having a overall size of 60x45 mm with reinforcement of 1 mm
thickness and sash with overall size of 39x58 mm with reinforcement of
1.5mm thickness. Glazing bead for fixing ofglass shall be of size 20x18mm
and coextruded with gasket. Windows shall be provided with 5mm plain
Sqm 3026.00
float glass, standard hardware & single point locking system of flush lock,
Wall thickness of frame & sash shall be 2-2.2 mm. (P.No. 301/ I. No.
38.44.1 of CSR 2015-16

Page 213 of 375


38.44.2 Providing & fixing of glazed Openable Window made out of multi chambered
uPVC sections with TPV gaskets having isolated drainage and reinforced
with Galvanixed iron profiles throuhout the window. The outer frame
having a overall size of 60x55 mm with reinforcement of 1 mm thickness,
mullion with overall size of 74x60 mm with reinforcement of 1 mm and
sash with overall size of 75x60 mm with reinforcement of 1.5 mm
thickness. Glazing bead for fixing of glass shall be of size 34x20 mm and
Sqm 3632.00
coextruded with gasket. Windows shall be provided with 5mm plain float
glass, standard hardware & single point locking system of flush lock, Wall
thickness of frame, mullion & sash shall be 2-2.2 mm.

38.44.3 Providing & of Fixed Louvered Ventilator made out of multi chambered
uPVC sections with TPv gaskets having isolated drainage and reinforced
with Galvanized Iron profiles through out the windown. The outer frame
having a overall size of 60x55mm with reinforcement of 1 mm thickness
and Mullion with overall size of 74x60mm with reinforcement of 1 mm Sqm 4540.00
thickness. Ventilator shall be provided with 4.5 mm Pin Head glass,
standard hardware, Wall thickness of frame Mullion shall be 2-2.2 mm.

Page No. 308


38.44.4 Providing & fixing of Top hung Ventilator With Exhaust Fan Provision made
out of multi chambered uPVC sections with TPV gaskets having isolated
drainage and reinforced with Galvanized Iron profiles through out the
Windown. the outer frame having a overall size of 60x55 mm with
reinforcement of 1 mm thickness, Mullion with overall size of 74x60 mm
with reinforcement of 1 mm thickness and Sash with overall size of 75x60
mm with reinforcement of 1.5mm thickness. Glazing bead for fixing of glass
Sqm 5220.00
shall be of size 34x20 mml coextruded with gasket, Ventilator shall be
provided with 4.5 mm Pin Head glass, standard hardware, single point
locking and friction stays,. Wall thickness of frame, mullion & sash shall be
2-2.2 mm.

38.44.5 Providing & fixing of glazed 3 Track - 2 Panel Sliding Windown With Mesh
made out of multi chambered uPVC sections with TPv gaskets having
isolated drainage and reinforced with GI throughtout the window. the
sliding outer frame having a overall size of 108x45 mm with reinforcement
of 1 mm thickness, sash with overall size of 39x58 mm with reinforcement
of 1.5 mm thickness, mesh sash of overall size 30x48.5 mm reinforced with
1.5 mm of GI. Glazing bead for fixing kof glass shall be of size 20x18mm Sqm 4917.00
and coextruded with gasket. Fiber Glass mesh shall be provided in mesh
shutter. Windows shall be provided with 5 mm plain float glass, standard
hardware and single point locking system of flush lock. Wall thickness of
frame, mullion & sash shall be 2-2.2 mm.

38.44.6 Providing & fixing of glazed 3 Track - 2 Panel Sliding Door made out of
multi chambered uPVC sections with TPV gaskets having isolated drainage
and reinforced with Galvanized Iron profiles through out the window. The
sliding outer frame having a overall size of 60x45 mm with reinforcement of
1 mm thickness, super sas with overall size of 39x75 mm with
reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be
of size 20x18 mm and coestruded with gasket. Fiber Glass mesh shall be Sqm 5675.00
provided in mesh shutter. Window/Door shall be provided with 6 mm plain
float glass, stgandard hardware & multi point locking system of patio
espagnolette. Wall thickness of frame, mullion
& sash shall be 2-2.2 mm.

38.44.7 Providing & fixing of glazed 3 Track - 2 Panel Sliding Door With Mesh …
made out of multi chambered uPVC sections with TPV gaskets having
isolated drainage and reinforced with Galvanized Iron profiles through out
the window. The sliding outer frame having a overall size of 108x45 mm
with reinforcement of 1 mm thickness, super sash with overall size of
39x75 mm with reinforcement of 1.5 mm thickness, mesh sash of overall
size 30x48.5 mm reinforced with 1.5 mm of GI.Glazing bead for fixing of Sqm 5675.00
glas shall be of size 20x18mm and coextruded with gasket. Fiber Glass
mesh shall be provided in mesh shutter. Window/Door shall be provided
with 6 mm plain float glass, standard hardware & multi point locking
system of Patio espagnolette. Wall thickness of frame, mullion & sash shall
be 2-2.2 mm.

Page No:309

Page 214 of 375


38.44.8 Providing & fixing of Openable window made out of multi chambered uPVC
(Matching to RAL-9016) sections and with minimum TiO2 (Titanium
Dioxide) at 6PHR with TPV (Thermo Plastic Vulcanized) and lead free with
gaskets-grey colour having isolated drainage and reinforced with
Galvanized Iron profiles through out the Openable frame. The frame having
a overall size of 60x55 mm with GI reinforcement of 1 mm thickness and
openable sash with overall size of 60x75mm and GI reinforcement of 1.5 Sqm 5448.00
mm thickness.Glazing bead for fixing of glas shall be of size
20x34mm.Windows shall be provided with 5 mm plain float glass, standard
hardware with friction hing & multi point locking system with handle. Wall
thickness of frame & sash shall be 2-2.5 mm.Maximum possible size -
900mmx1819mm.

38.45 Consultancy services for Preparation of Land Plan Survey for state
Highways and major District roads The entire Land Survey Plan should be
carried out using LiDAR Technology only, Collection of all the relevant
information for 50 Mtr on either side from The entire Land Survey Plan
should be carried out using LiDAR Technology only, Collection of all the
relevant information for 50 Mtr on either side from centre of the road,
Details of Structures (if any), Cross Drainage Structures, Arboriculture
counts and other Assets, which have been developed as a part of the road
furniture / development. Establishing the Primary Control Points
(Horizontal Control), using the DGPS at every 1000 meters interval and
secondary control points at every 500 meters and also at important and
salient locations, such as major inter sections, Village / Town limits etc.,.
The DGPS controls will be so established that it meets the minimum criteria
specified for carrying out the mapping activities on a scale of 1:5000 or
1:10000. (Inclusive of all taxes) NOTES: (a) The DGPS control points
established will be further extended using the total station for densification
so that there are Control Points for every 200 m interval at staggered KM 4500.00
locations. All Physical details shall be picked up for a width of 50M from the
center line on either side of the road. Primary control points shall be a
properly monumented using Cement Concrete Pillar (RCC) of size 230 mm x
230 mm x 1250 mm, out of which 550 mm is embedded in Cement
Concrete below the ground level. All such Pillars shall be serially numbered
and painted in two coats of Golden Yellow Colour. The X, Y, Z co-ordinates
shall be referred to center of the Pillar marked on top of it. The co-ordinates
shall be painted in red color. A list of all Primary and Secondary control
points with X,Y,Z Co-ordinate should be submitted.
Original Revenue Village Survey Maps will be collected from revenue
authorities and all the Control Points shall be physically verified and
marked on top of it. (a. RTC and other information required shall be
collected by the Consultants from the appropriate authorities, b. Within
RoW, if there are any encroachments, then the consultant shall get relevant
records and prepare the relevant documents for transferring RTC in the
name of PWD.) Cadastral (Revenue) Survey will be carried out in order to
demarcate the Right of Way of the road and also of all the encroachments. A
38.46 Providing and fixing self-supported, ribbed, high quality, high grade (D:350
MPA Yst Min ), pre- painted Galvalume steel roof sheet, coated with bare
Galvalume coating AZ 150, @ 150 gms/Smtr 55%AL,45%Zn) by hot dip
process , of total coated thickness as specified for different spans with a
tolerance of +/- 0.02 mm, according to technical specification confirming to
A 792, with NCCA ll-1, or ECCA T4 Pencil hardness HB, NCCA standard T-
Bend test. The roof should be fastened to the gutter beam, on the external
sloping side, at an interval of 51mm Centre to Centre, to a depth of 65 mm
with GI anchor bolts and neoprene washers & subjecting the gutter beam to
Schmidt, Hammer test to ensure the anchorage of the anchor bolts. The
self-supported roofing system should be designed to with stand the wind
load (As per IS 875 part-3) & Earthquake load (as per IS 1893) & the design
should also comply with any other technical requirements such as turbo
ventilators of 0.60 mts. dia and skylights of size 4.26 x 0.60 mts. fixed one
in each row @ 10.00 Mtr C/C along the length & hangers for electrical
fixtures as per the requirements including cost of all materials &labour for
erection, all lead and lift, loading and unloading, HOM of machineries etc.,
complete as per the standard detailed technical specification, design and
directions of the engineer in charge of the work.
Page No. 310
38.46.1 (a) Span : 9 Meters upto 15 Meters (b) Material Specification: Colour Coated
Galvalume Sheet, weighing 10.10 kg/sqm BMT: 0.80 MM, APT : 0.85 MM, sqm 1560.00
tolerance +/- 0.02mm
38.46.2 a) Span :Above 15 Meters upto 18 Meters (b) Material Specification: Colour
Coated Galvalume Sheet, weighing 11.35 g/sqm BMT: 0.90 MM, APT : 0.95 sqm 1650.00
MM, tolerance +/- 0.02mm
38.46.3 (a) Span : Above 18 Meters upto 21 Meters (b) Material Specification: Colour
Coated Galvalume Sheet weighing 12.57kg/sqm BMT: 1.00 MM, APT : 1.05 Sqm 1740.00
MM, tolerance +/- 0.02mm
38.46.4 (a) Span : Above 21 Meters upto 23 Meters (b) Material Specification: Colour
Coated Galvalume Sheet weighing 13.80kg/sqm BMT: 1.10 MM, APT : 1.15 Sqm 1875.00
MM, tolerance +/- 0.02mm

Page 215 of 375


38.46.5 (a) Span : Above 23 Meters upto 25 Meters (b) Material Specification: Colour
Coated Galvalume Sheet, weighing 15.16kg/sqm BMT: 1.20 MM, APT : 1.25 Sqm 2000.00
MM, tolerance +/- 0.02mm
38.46.6 (a) Span : Above 25 Meters upto 27 Meters (b) Material Specification: Colour
Coated Imported Galvalume Sheet, weighing 16.40 kg/sqm BMT: 1.30 MM, Sqm 2050.00
APT : 1.37 MM, tolerance +/- 0.02mm
38.46.7 (a) Span :Above 27 Meters upto 30 Meters (b) Material Specification: Colour
Coated Imported Galvalume Sheet, weighing 17.63 kg/sqm BMT: 1.40 MM, Sqm 2185.00
APT : 1.47 MM, tolerance +/- 0.02mm
38.46.8 (a) Span :Above 30 Meters upto 32 Meters (b) Material Specification: Colour
Coated Imported Galvalume Sheet, weighing 18.87 kg/sqm BMT: 1.50 MM, sqm 2320.00
APT : 1.57 MM, tolerance +/- 0.02mm
Page No. 311
38.46.9 (a) Span : Above 32 Meters upto 35 Meters (b) Material Specification: Colour
Coated Imported Galvalume Sheet, weighing 20.10kg/sqm BMT: 1.60 MM, sqm 2410.00
APT : 1.67 MM, tolerance +/- 0.02mm
38.47 Providing and applying a heat reflecting anti-fungal water based, flexible,
water proofing, roof coating for use on Roof/Terrace/Parapet. by
formulating the undercoat with polymer modified cementations water proof
slurry mortar and top coat consisting of 100% Acrylic Elastometric
Ploymers embedded with heat reflecting particles. For surfaces having
cracks less than 5mm.

38.47.1 do: - in high rainfall areas(Two layers of under coat plus two layers of top
sqm 490.00
coat)
38.47.2 do: - in low rainfall areas(One layers of under coat plus two layers of top
sqm 437.00
coat)
38.48 Construction of embankment / sub grade using nanotechnology based
chemical stabilizer and Cement.
38.48.1

Construction of embankment using nanotechnology material.


Construction of embankment with approved material gravel/murrum and
chemical stabilized like nanotechnology based organosilane or equivalent
(confirming to the required spec.) mixed in water @0.5kg/ cum (for soil CBR cum 790.00
above 5%) and 1% cement by weight of soil, with all lifts and leads,
transporting to site, spreading, grading to required slope and compacting to
meet requirement table 300-2 complete as per specifications. (Which
includes cost of gravel/murrum, watering charges & compacting by
vibratory roller) MORTH Specification No. 305
38.48.2
Construction of embankment with material deposited from roadway
cutting using nanotechnology material. Construction of Embankment
with approved material deposited at site from roadway cutting and
excavation from drain and foundation of other structures graded and
chemical stabilizer like nanotechnology based organolilane or equivalent cum 660.00
(confirming to the required spec.) Mixed in water @ 0.5kg/ cum and 1%
cement by weight of soil and compacted to meet requirement of table 300-2
complete as per specifications. (Which includes, watering charges &
compacting by vibratory roller) MORTH Specification No. 305

38.48.3

Construction of subgrade and earthen shoulders using nanotechnology


material: Construction of sub-grade and earthen shoulders with approved
material gravel/murrum and chemical stabilizer like nanotechnology based
organosilane or equivalent (confirming to the required spec.) Mixed in water cum 794.00
@ 0.5kg/cum (for soil CBR above 5%) and 1% cement by weight of soil with
all lifts & leads, transporting to site, spreading, grading to required slope
and compacted to meet requirement of table no. 300-2 complete as per
specifications (Including cost of earth, watering charges & compaction by
vibratory roller) MORTH Specification No. 305
Page No. 312
38.48.4 Loosening of the ground upto a level of 500mm below the subgrade level,
watered, graded and compacted in layers to meet requirement of table 300-
2 for subgrade construction complete as per specifications. Case-I :
Compacting original ground supporting subgrade using chemical stabilizer
like nanotechnology based organosilane or equivalent (confirming to the cum 632.00
required spec.) mixed in water @ 0.5kg/cum and 1% cement by weight of
soil, (which includes water charges & compaction by vibratory roller).
MORTH Specification No. 305.3.4

Page 216 of 375


38.48.5 Loosening, levelling and compacting original ground supporting
embankment to facilitate placement of first layer of embankment, scarified
to a depth of 150mm, mixed with water at OMC and then compacted by
rolling so as to achieve minimum dry density as given in table 300-2 for
embankment construction. Compete as per specifications. Case – II :
Compacting original ground supporting embankment using chemical
cum 610.00
stabilizer like nanotechnology based organosilane or equivalent (confirming
to the required spec.) mixed in water @0.5kg/cum and 1% cement by
weight of soil (which includes watering charges & compaction by vibratory
roller) MORTH Specification No. 305.3.4

38.49 METALIC DOOR FRAMES


38.49.1
Door Frame - Entrance : Providing & fixing factory made Galvanized plain
steel door frame of profile size 125 x 60 mm single rebate manufactured
from galvanized plain steel sheet 1.25 mm thick, conforming to IS:277. The
door frame consists of hinge jamb, lock jamb, head & bottom tie bars,
supply in knockdown condition & to be assembled at site by mechanical
means with special mitre joint. The bottom tie bar made out of galvanized
plain steel sheet 1.60 mm thick pressed angle 20 x 20 mm screwed to the
door frame. The stiffeners of 3 mm thick pre- punched & pre-trapped are to
be welded inside the pre-punched slots of the door frames & 4 nos. of S.S. rmt 545.00
butt hinges 100 x 59 x 2.5 mm to be screwed to the door frame. The
necessary stiffeners & mortar guards to be provided for fixing hardware
fixtures. The door frame to be powder coated after pre- treatment of the
surface. The door frame shall be filled with 1:3:6 cement concrete & to be
fixed with adjustable lugs/ hold fasts. Alternatively, dry fixing shall be
permitted by using metallic expansion bolt. The rate is including
transportation, loading, unloading, HOM etc. but excluding the hardware
fixtures. size 1000 x 2130 mm

38.49.2
Door Frame - Internal: Providing & fixing factory made Galvanized plain
steel door frame of profile size 125 x 60 mm single rebate manufactured
from galvanized plain steel sheet 1.25 mm thick, conforming to IS: 277. The
door frame consists of hinge jamb, lock jamb, head & bottom tie bars,
supply in knockdown condition & to be assembled on site by mechanical
means with the special miter joint. The bottom tie bar made out of
galvanized plain steel sheet 1.60 mm thick pressed angle 20 x 20 mm to be
screwed to the door frame. The 4 nos. of G.I. Lift off hinge 100 x 67 x 2 mm rmt 430.00
to be projected welded to the door frame. The necessary stiffeners & mortar
guards to be provided for fixing hardware fixtures. The door frame to be
powder coated after pre-treatment of the surface. The door frame shall be
filled with 1:3:6 cement concrete & to be fixed with adjustable lugs/ hold
fasts. Alternatively, dry fixing shall be permitted by using metallic
expansion bolt. The rate is including transportation, loading, unloading,
HOM etc. but excluding the hardware fixtures. size 900 x 2130 mm

Page No. 313


38.49.3
Door Frame – Wet areas – W.C. / bath: Providing & fixing factory made
Aluminium Zinc coated steel door frame of profile size 105 x 60 mm single
rebate manufactured from Aluminium Zinc metallic coated steel sheet 1.20
mm thick, conforming to IS: 15961. The door frame consists of hinge jamb,
lock jamb, head & bottom tie bars & supply in knockdown condition & to
be assembled on site by mechanical means with special mitre joint to be
bottom tie bar made out of galvanized plain steel sheet 1.60 mm thick
pressed angle 20 x 20 mm to be screwed to the door frame. The 3 nos. of
rmt 477.00
S.S. butt hinges 100 x 58 x 1.9 mm to be projection welded to the door
frame. The necessary stiffeners & mortar guards to be provided for fixing
hardware fixtures. The door frame to be powder coated after pre-treatment
of the surface. The door frame shall be filled with 1:3:6 cement concrete &
to be fixed with adjustable lugs/ hold fasts. Alternatively dry fixing shall be
permitted by using metallic expansion bolt. The rate is including
transportation, loading, unloading, HOM etc. but excluding the hardware
fixtures. size 750 x 2130 mm

38.49.4 Door Frame – Wet areas – W.C. / Bath: Do- with Profile Size 90 x 50 mm -
rmt 440.00
size 750 x 2130 mm
39.50 METALIC DOOR SHUTTERS

Page 217 of 375


38.50.1
Door Shutters Entrance : Providing & fixing factory made Galvanized steel
door Shutters 32 mm thick manufactured from pre- painted Galvanized
plain steel sheet 0.60 mm thick conforming to the IS: 14246. The door
shutters consist of two outer skins if steel sheets, lock seam jointed at
vertical stile edges, horizontal top & bottom sides to form a double skin
fully flush shell. Rigid polyurethane Foam (PUF) of density 40 Kg/M3 shall sqm 2140.00
be filled in the hollow portion of door shutters for structure rigidly & sound
insulation. The necessary stiffeners of the Galvanized plain steel sheet of
minimum thickness 1.60 mm to be provided for fixing all hardware fixtures.
The rate is including transportation, loading, unloading, HOM etc. but
excluding the hardware fixtures. size – 900 x 2035 x 32 mm thick.

38.50.2 Door shutters - internal - Do - of Size – 800 x 2035 x 32 mm thick. sqm 2230.00
38.50.3
Door shutters - Wet areas – W.C. / bath : Providing & fixing factory made
Galvanized steel door Shutters 32 mm thick manufactured from pre-
painted Aluminium-zinc metallic coated steel sheet 0.60 mm thick
conforming to the IS: 15961. The door shutters consist of two outer skins of
steel sheets, lock seam jointed at vertical stile edges, horizontal top &
bottom sides to form a double skin fully flush shell. Rigid polyurethane
sqm 2500.00
Foam (PUF) of density 40 Kg/M3 shall be filled in the hollow portion of door
shutters for structure rigidly & sound insulation. The necessary stiffeners
of Galvanized plain steel sheet of minimum thickness 1.60 mm to be
provided for all hardware fixtures. The rate is including transportation,
loading, unloading, HOM etc. but excluding the hardware fixtures. size –
650 x 2035 x 32 mm thick.

Page No. 314


38.50.4
Door shutters - Wet areas – W.C. / bath : Providing & fixing factory made
Galvanized steel door Shutters 32 mm thick manufactured from pre-
painted Aluminium-zinc metallic coated steel sheet 0.60 mm thick
conforming to the IS: 15961. The door shutters consists of two outer skins
of steel sheets, lock seam jointed at vertical stile edges, horizontal top &
bottom sides to form a double skin fully flush shell. Rigid polyurethane
sqm
Foam (PUF) of density 40 Kg/M3 shall be filled in the hollow portion of door
shutters for structure rigidly & sound insulation. The necessary stiffeners
of Galvanized plain steel sheet of minimum thickness 1.60 mm to be
provided for all hardware fixtures. The rate is including transportation,
loading, unloading, HOM etc. but excluding the hardware fixtures. size –
670 x 2045 x 32 mm thick.

38.52 Providing Stainless steel reinforcement (Duplex Grade - 532101) for RCC
work including straightening, cutting, bending, hooking, placing in
position, lapping and / or welding wherever required, tying with binding
wire and anchoring to the adjoining members wherever necessary complete Tonne 214452.00
as per design (laps, hooks and wastage shall not be measured and paid)
cost of materials, labour, HOM of machinery complete as per specifications.

38.53 Providing and mixing Alkali resistant integral glass fibers HD 67/36 to act
as a replacement of steel reinforcement in supported slabs and to provide
secondary reinforcement in concrete at 5 kg / cum of concrete, fibers of
length 36 mm, diameter 19 microns,specific gravity 2.68, modulus of
elasticity 72 Gpa and having the aspect ratio (length/dia) of 67, including cum 3100.00
cost of labour,materials and HOM of machineries etc
complete.(Note:The work to be carried out with prior permission of the
competent authourity.) ( NOTE: Rate is for cum of concrete)

38.54 Providing and applying 2 coats of corrosion Inhibitioncement slurry on


Reinforcement bars prepared by mixing of 1kg of OPC with 500CC of
Inhibitor solution of approved quality by dipping or brushing method, the
first coat being applied after cleaning the bars by wire brush or alkaline
cleaning powder to remove the rust and dust, and allowed to air dry for 12-
24 hours as the case may be and the second coat being applied on the Tonne 1670.00
fabricated bars before placing in position as per clause 5.3.3 of IS 9077-
1979. The rate includes cost and conveyance of all materials, labour
charges etc., complete as per the direction of Engineer in-charge.

Page 218 of 375


38.55 Providing and laying self-compacting controlled concrete produced by IS
9001 accredited plants confirming to EN 206-1 M-20 grade, with OPC @
185kg/cum confirming to EN-197-1 GGBS 175kg/cum, 20mm to 12.50mm
graded coarse aggregates @ 865kg/cum, confirming to EN-12620 obtained
from a single source with a cieling flakiness index of 5%, M-sand @ 1015
kg/cum, having aggregate particles finer than 45 microns, limitted to 8%
(2% for natural sand) and water cement ratio as per EN 1008, with vertical cum 4824.00
free fall distance and horizontal flow for concrete from point of discharge
limitted to 5m & 10mts respectively including cost of all materials, labour
charges, scaffolding, curing, hire charges of machineries etc., complete as
per the direction of Engineer-in-charge of work.

Page No. 315


38.56 Providing and laying self-compacting controlled concrete produced by IS
9001 accredited plants confirming to EN 206-1 M-25 grade, with OPC @
255kg/cum confirming to EN-197-1 GGBS 145kg/cum, 12.5mm graded
coarse aggregates @ 745kg/cum, confirming to EN-12620 obtained from a
single source with a cieling flakiness index of 5%, M-sand @ 1065 kg/cum,
having aggregate particles finer than 45 microns, limitted to 8% (2% for
natural sand) and water cement ratio as per EN 1008, with vertical free fall cum 5235.00
distance and horizontal flow for concrete from point of discharge limitted to
5m & 10mts respectively including cost of all materials, labour charges,
scaffolding, curing, hire charges of machineries etc., complete as per the
direction of Engineer-in-charge of work.

38.57 Providing and laying self-compacting controlled concrete produced by IS


9001 accredited plants confirming to EN 206-1 M-30 grade, with OPC @
275kg/cum confirming to EN-197-1 GGBS 185kg/cum, 12.5mm graded
coarse aggregates @ 790kg/cum, confirming to EN-12620 obtained from a
single source with a cieling flakiness index of 5%, M-sand @ 990kg/cum,
having aggregate particles finer than 45 microns, limitted to 8% (2% for
natural sand) and water cement ratio as per EN 1008, with vertical free fall cum 5600.00
distance and horizontal flow for concrete from point of discharge limitted to
5m & 10mts respectively including cost of all materials, labour charges,
scaffolding, curing, hire charges of machineries etc., complete as per the
direction of Engineer-in-charge of work.

38.58 Providing and laying self-compacting controlled concrete produced by IS


9001 accredited plants confirming to EN 206-1 M-35 grade, with OPC @
305kg/cum confirming to EN-197-1 GGBS 195kg/cum, 12.5mm graded
coarse aggregates @ 800kg/cum, confirming to EN-12620 obtained from a
single source with a cieling flakiness index of 5%, M-sand @ 970kg/cum,
having aggregate particles finer than 45 microns, limitted to 8% (2% for
natural sand) and water cement ratio as per EN 1008, with vertical free fall cum 5910.00
distance and horizontal flow for concrete from point of discharge limitted to
5m & 10mts respectively including cost of all materials, labour charges,
scaffolding, curing, hire charges of machineries etc., complete as per the
direction of Engineer-in-charge of work.

38.59 Providing and laying self-compacting controlled concrete produced by IS


9001 accredited plants confirming to EN 206-1 M-40 grade, with OPC @
400kg/cum confirming to EN-197-1 GGBS 105kg/cum, 12.5mm graded
coarse aggregates @ 910kg/cum, confirming to EN-12620 obtained from a
single source with a cieling flakiness index of 5%, M-sand @ 820kg/cum,
having aggregate particles finer than 45 microns, limitted to 8% (2% for
natural sand) and water cement ratio as per EN 1008, with vertical free fall cum 6185.00
distance and horizontal flow for concrete from point of discharge limitted to
5m & 10mts respectively including cost of all materials, labour charges,
scaffolding, curing, hire charges of machineries etc., complete as per the
direction of Engineer-in-charge of work.

Page No. 316

Page 219 of 375


38.60 Light gauge steel frame structure (LGSFS) for dry wall panel system
Providing and fixing factory finished custom designed stucturally stable,
corrosion resistant, cold formed wall structure, trusses, joists, purlins,
connection accessories etc., made out of 0.95mm thick galvanised steel
coils, (AZ - 150 gms, Aluminium-Zinc alloy coated steel) having minimum
yield strength of 550 Mpa, using computerized cold forming machine to 'C'
type sections having a minimum web thickness of 89 mm, flange width
40mm with 10mm lip as per drawings confirming to AISI specifications and
IBC 2009 for cold formed steel and construction confirming to Indian
standards as per IS:800-1984, IS:801-1975, IS:875-1987 (Part III) and Kg 155.00
IS:1893, the LGS frames shall be manufactured using computerized
machine duly punched with dimple, service holes and slots at reguired
location and supplied in assembled state using self tapping screws with
corrosion resistant coating in accordance with ASTM B633 of specified
pitch as per requirements or in a dismantled state, and mounted/firmly
fixed to the exsisting plinth beam using self expandable carbon steel anchor
bolts, 12mm dia and 121mm in length confirming to AISI 304 & 306
standards @ 500mm c/c with a minimum embedment of 100 mm in RCC
located at 300 mm from corners or from bottom LGS frames confirming to
38.61 Specifications
Providing andincluding all costs
fixing with of labour,
internal materials,
and external fabrication,
cement fibre
boards/coir composite boards to LGSFS dry wall panel system Providing
and fixing for both external and internal faces of Light Gauge Steel Frame
Structure in two layers, sandwiching a breathable vapour barrier in
between layers as per NBC code 2009, with external face having a 6mm
thick heavy duty fibre cement board/coir composite board fixed on a 9mm
thick heavy duty fibre cement board/coir composite board confirming to IS
14862:2000, Category IV type A or equivalent in standard sizes and internal
face with 12.5mm thck gypsum plaster board/coir composite board fixed on
8mm thick fibre cement board/coir composite boards confirming to IS Sqm 2960.00
14862:2000 of category III type B (High pressure steam cured ) or
equivalent, as per standard sizes with self drilling tapping screws half
counter sunk, rib head of 1.60mm to 4mm thick, 8 to 10 gauge, length
varying from 25 to 45mm/fasteners @ 600mm c/c of approved make, with
a staggered vertical joint of 2mm to 3mm sealed with a silicon based
sealant and smooth finished using fiber mesh tape and Epoxy and acrylic
based joining compound for seamless finish and the material and process of
manufacture and assembly/erection confirming to Specifications including
all costs of labour, materials, fabrication, assembling, transportation,
38.62 Providing and fixing with EPS-weld mesh-cement-sand shotcrete wall
panels to LGSFS. Providing
and fixing in position factory made expanded polystyrene core (EPS core)
panels 90mm thick having a density not less than 10kg per cum. to both
faces of LGSFS for walls and covered on both sides with welded wire fabric
mesh made of 2.2mm dia GI wire with 50mm pitch in boy the directions,
connected by GI wire of 3mm dia to the LGS frame structure duly plaster
finished with shotcrete plastering/guniting equipment in required layers,
30mm thick with cement mortar 1:3 {1 cement:3 coarse sand not having
more than 40% stone chips of size upto 6mm} at a pressure not less than 1 Sqm 2890.00
bar (100 KN/m2) and both faces finished with trowel and completed in all
respect as per drawings and specifications confirming to Specifications
including all costs of labour, materials, fabrication, assembling,
transportation, erection, incidental and unforseen charges complete as per
the directions of the engineer in charge of the work.

Page No. 317


38.63 Providing and fixing with EPS-weld mesh-cement-sand shotcrete
roof/floor panels to LGSFS.
Providing and fixing in position factory made expanded polystyrene core
(EPS core) panels 90mm thick having a density not less than 10kg per cum.
to both faces of LGSFS for walls/floor panels and covered on both sides
with welded wire fabric mesh made of 2.2mm dia GI wire with 50mm pitch
in both the directions, connected by GI wire of 3mm dia to the LGS frame
structure duly plaster finished with shotcrete plastering/guniting
equipment in required layers, 30mm thick with cement mortar 1:3 {1
cement:3 coarse sand not having more than 40% stone chips of size upto Sqm 3020.00
6mm} at a pressure not less than 1 bar (100 KN/m2) and both faces
finished with trowel and completed in all respect as per drawings and
specifications confirming to Specifications including all costs of labour,
materials, fabrication, assembling, transportation, erection, incidental and
unforseen charges complete as per the directions of the engineer in charge
of the work.

Page 220 of 375


38.64 COIR COMPOSITE DOORS
Engineered Coir Composite Flush Door Shutter of 30mm Thick.
Providing and fixing engineered coir composite flush door shutter
manufactured using infill solid core wth coir and wood particle blended
with high quality polymer encased with 28mm thick wooden styles and rails
all-round the boundary of the shutter and veneer laminated with non oven
coir felt impregnated with high temprature cure phenol formaldehyde resin
of density 800kg/cum with high quality adhesive processed at 155 Deg. C,
using 650 tonnage hot compression moulding press and all four sides of the Sqm 2000.00
door shutter coated with water resistant coating and whole process of
manufacturing confirming to Specifications including all cost of labour,
materials, fabrication, assembling, transportation, erection, incidental and
unforseen charges complete as per the directions of the engineer in charge
of the work, but excluding yhe cost of fixtures and painting.

38.65 Engineered wood plastic Composite door frames with cross section of
55x110mm
Providing and
fixing engineered wood door frame size fabricated using wood plastic
composites profiles (WPC) of cross section 55mm x 110 mm with a density
of 1250-1300 kg/m3, resistant to water, termite, fungal and UV, using four
numbers of L shaped MS or plastic clamps at the corners of the frame and
provided with six numbers of 260mmx25mmx5mm size z shaped MS flat rmt 700.00
hold fasts for fixing the door frame in the wall and the material and process
for manufacturing the door frame confirming to Specifications including all
cost of labour, materials, fabrication, assembling, transportation, erection,
incidental and unforseen charges complete as per the directions of the
engineer in charge of the work, but excluding the cost of fixtures and
painting.

Page No. 318


38.66 Engineered wood plastic Composite door frames with cross section of
75x125mm
Providing and
fixing engineered wood door frame size fabricated using wood plastic
composites profiles (WPC) of cross section 75mm x 125 mm with a density
of 1250-1300 kg/m3, resistant to water, termite, fungal and UV, using four
numbers of L shaped MS or plastic clamps at the corners of the frame to fix
it firmly to a rectangular shape door frame and provided with six numbers rmt 1300.00
of 260mmx25mmx5mm size z shaped MS flat hold fasts for fixing the door
frame in the wall and the material and process for manufacturing the door
frame confirming to Specifications including all cost of labour, materials,
fabrication, assembling, transportation, erection, incidental and unforseen
charges complete as per the directions of the engineer in charge of the
work, but excluding the cost of fixtures and painting.

38.67 Engineered wood plastic Composite window frames with cross section
of 55x110mm
Providing and
fixing engineered wood window frame fabricated using wood plastic
composites profiles (WPC) of cross section 55mm x 110 mm with a density
of 1250-1300 kg/m3, resistant to water, termite, fungal and UV, using four
numbers of L shaped MS or plastic clamps at the corners of the frame to fix
it firmly to form a rectangular shape door frame and provided with six
numbers of 260mmx25mmx5mm size z shaped MS flat hold fasts for fixing Sqm 3850.00
the Window frame in the wall, MS rods of 12mm dia are provided in window
frame as per design and drawings. The material and process for
manufacturing the door frame confirming to Specifications including all
cost of labour, materials, fabrication, assembling, transportation, erection,
incidental and unforseen charges complete as per the directions of the
engineer in charge of the work, but excluding the cost of fixtures and
painting.

38.68 Providing and fixing in position half paneled window shutters with wood
plastic composite styles and rails of 30mm thick, 65mm wide and with
4mm thick reeded glass panels fixed in the groves provided in the styles
and rails and the material and process for manufacturing the window
shutters confirming to specifications including all cost of labour, materials, Sqm 2200.00
fabrication, assembling, transportation, erection, incidental and unforseen
charges complete as per the directions of the engineer in charge of the
work, but excluding the cost of fixtures and painting.

Page No. 319

Page 221 of 375


38.69 Providing and supplying water proofing membrane of size 1m x 5m with 6.4
mm thick having a puncture resistance of 620N as per ASTM D 4833 and
hydrostatic pressure resistance upto 70m as per ASTM D 5385 consisting
of Bentonite granuals weighing 4.80 kg/sqm encased between needle
punched non-oven geotextile covered with HDPE sheet of 200 microns thick
and uncovered oven geotextile on the other side laid over levelling concrete
to arrest subsurface water with a staggered over lapping of 100 mm and
with a minimum staggered lapping of 300mm at the corners and the laps
secured by washer headed mechanical fasteners spaced at 300 mm c/c and Sqm 880.00
the lap joints are sealed with Bento seal of not less than 19mm thick and
the terminated ends af water proofing membrane is covered with aluminium
strip and Bento seal., complete including the cost of lapping, materials,
labour, complete as per specifications.
Ref: ASTM D 4833, ASTM D 5385, ASTM D 3776, ASTM D 903,
ASTM D 5084, ASTM D 4632, ASTM D 1970, ASTM E 96.

38.70 Migrating Corrosion Inhibiting Admixture


Providing and applying corrosion inhibiting admixture at a dose of
3 kgs per cum of concrete. The admixture should protect both cathodic and
anodic sites and should have accredited by Indian Roads Congress,
recommended for use by Ministry of Road Transport & Highways.
Admixture should have evaluated test reports demonstating a corrosion
rate of zero coulombs after 9 test cycles as per ASTM G 109. PH of
admixture should be alkaline in nature, specific gravity of 0.99 - 1.1,
colour:brownish. The contractor must
intimate the engineer in charge prior to addition in concrete for recording. If cum 340.00
the admixture is put in the concrete mix at the batching plant, a written
record of the amount of admixture used shall be supplied to the engineer.
The engineer must ensure that the specified dosage of admixture is added
in the concrete mix.

38.71 High performance Anti carbontion protective coating


Providing and
applying primer and two coats of of 100% acrylic breathable, water based,
anti-carbonate coating. Coating to be
applied at the rate 300 g/m2. Minimum DFT of coating to be 225 micron.
The coating shall have atleast a 4 year track record of use as an anti-
Sqm 226.00
carbonation coating and shall have the test reports evaluated from ministry
of new and renewable Resources supported laboratory demonstrating solar
reflectance index (ASTM E 1980-11, EN 673:2011, EN 410:2011)>104.
1. Carbon dioxide diffusion
equivalent air layer thickness (DIN EN

Page No. 320 1062-6)>100m


38.72 Water Proofing
Providing and applying compatible PU based primer + 2 coats of Single
component, high solids, cold applied liquid polyurethene elastomer
waterproof membrane over uniform surface of slab. Apply 2 coats at dosage
of 1.5kgs per sq. mtr total with minimum total WFT (Wet Film Thickness) of
1.5mm to achieve the required minimum DFT of 1.2mm. This should be
fallowed by application of protective plaster. The manufacturer of the liquid
membrane shall be Dakks ISO 9001:2015 accredited for manufacturing
and design. Liquid applied, polyurethane waterproofing membrane should Sqm 1459.00
have fallowing minimum properties: 1. Water permeability (DIN
1048) - Nil as per DIN 1048 $ 7 bar of hydrostatic pressure
2. Moisture
permeability-<0.4g/m2/day 3.
Accelerated Weathering (IS 101)- 2000 hrs No cracking or blister formation.
4.
Adhesion to concrete (ASTM D 1000)->21kg/cm2 (Concrete Fails)
5. Tensile Strength>2.0 MPa (ASTM D412)
38.73 Structural Steel Coatings
Cleaning the existing steel surface by mechanical means such as sand
blasting so as to remove all the exsisting loose rust etc. Using cotton waste
swab apply rust converting, steel passivating, flash rust preventing
sulphate and chloride free, non-alkaline, inorganic single component, rust
converter and nano film forming surface passivator. After 24 hours remove
the free/loose rust particles by simple dusting with brush. Providing and
applying one coat of Two component, anticorrosive, solvent free, substituted Sqm 330.00
long chain nylon reticulant based epoxy coating/primer. This should be
fallowed by two coats of protective two component, APR based, UV resistant
anticorrosive coating. Apply the coats by brush or spray at 4-6 hours
interval between each coat.

Page 222 of 375


Page No. 321
38.74 Providing and fixing Sacrficial Anode for damaged RCC Member such
as slab, beam, column etc
Providing and fixing zinc alloy based galvanic disk type sacrificial
anodes (50 mm dia, 18mm thick) to the reinforcement and pass 500 hours Sqm 892.00
salt spray test as per ASTM B 117, The anode shall be connected to the
reinforcement steel by connectors provided with the anode.

38.75 Coir Textile


Supplying and installaion of 700 gsm/sqm over sub-grae formation as per
standard road specification will be laid- wrinkly free using hooks 150mm
"U" shaped and sharp edges at both ends on the periphery of the geo-
textiles on both sides at c/c 2.5MTRS. and providing lap width of 100 cms. Sqm 120.00
mixing with "U" shaped and shaped hooks at 1.5cms c/c cost inclusive of
transportation, loading, unloading and labour charges as per directions of
Engineer incharge of the work.

Page No. 322

39.0 39.FURNISHING WORK


39.1 Providing and fixing veneer paneling over the 50mm x 35mm sal wood
frame work and top covered out of 4mm thick approved veneer fixed over
12mm ply finished in mealamme polish, complete including cost and
conveyance of all materials, labour for all items of work HOM of equipment Sqm 3739.00
etc., complete as per specification. (P.No.311, I.No. 39.1 of PWD SR 2015-
16)

39.2 Providing and fixing acoustic Veneer paneling, over the 50mm x 35mm sal
wood frame work at spacing not exceeding 600mm c/c fixed to the wall and
top covered out of 4mm thick approved quality Veneer, fixed over 19mm
thick ply strips of 100mm to 200mm with a gap of 6 to10mm in between
strips of approved brand termite and water resistance, finished with Sqm 6310.00
melamine polish, complete including cost and conveyance of all materials,
labour for all items of work, HOM of equipment complete as per
specification.

39.3 Manufacturing, supplying and fixing wooden ward robe of 0.60m deep
using 19mm thick vinyl bonded water proof block board, shutters allround
ward robe, lockable drawers with sliding channels, cupboard drapery
hangers, curtain rods with end brackets, openable shutters with 19mm x
6mm thick plain teak wood beading, lipping 1.5mm thick commercial ply
vertical support finished in approved 1.5mm lamination sheet of approved
colour, shade and quality on all exposed surfaces. Inner surface painted
with 2 coats of white synthetic enamel paint over 2 coats of Patti, one coat Sqm 10752.00
of wood primer, including cost of brass fittings, parliamentary hinges, C
handles, tower bolts, magnetic catches, approved brand lock, adhesives,
synthetic resins, nails, screws etc., complete including cost of all materials,
labour charges, complete as per specification. (P.No.311, I.No. 39.3 of PWD
SR 2015-16)

39.4 Providing and fixing storage unit of 0.75m width made out of 19mm thick
commercial ply vertical support finished in approved 1.5mm laminate with
12mm thick ply packing internally finished with enamel paint of approved
colour and shade shelves shall be formed out of 19mm ply finished with
enamel paint of approved shade and colour and 19mm thick shutters Sqm 13070.00
formed out of 19mm thick ply finished with 1.5mm thick laminate of
approved shade and colour etc., complete the rate includes cost of all
materials, labour charges, complete as per specification.(P.No. 311, I.No.
39.4 of SR 2015-16)

39.5 Providing and fixing Single shutter glass door of 12mm thick plain
toughened glass (Saint Gobain, Modi float). The door is fixed by using any
approved make hardware fitting like patch fitting, pivot, floor machine,
locking arrangements and suitable SS door rails with floral glass etching for Sqm 8936.00
1/3 portion of door area etc complete. The rate includes cost of all
materials, labour, hire of tools & machineries,and as per specification.

39.6 Providing and fixing Double shutter glass door of 12mm thick plain
toughened glass of approved make (Saint Gobain, Modi float). The door is
fixed by using any approved make hardware fitting like patch fitting, pivot,
floor machine, locking arrangements and suitable SS door rails with floral Sqm 8046.00
glass etching for 1/3 portion of door area etc complete. The rate includes
cost of all materials, labour, hire of tools & machineries, as per the
specification.

Page No. 324

Page 223 of 375


39.7 Providing and fixing Single shutter glass door of 12mm thick frosted
toughened glass of approved make (Saint Gobain, Modi float). The door is
fixed by using any approved make hardware fitting like patch fitting, pivot,
floor machine, locking arrangements and suitable SS door rails with floral Sqm 9388.00
glass etching for 1/3 portion of door area etc complete. The rate includes
cost of all materials, labour, hire of tools & machineries, as per
specification.

39.8 Providing and fixing Double shutter glass door of 12mm thick frosted
toughened glass of approved make (Saint Gobain, Modi float). The door is
fixed by using any approved make hardware fitting like patch fitting, pivot,
floor machine, locking arrangements and suitable SS door rails with floral Sqm 8508.00
glass etching for 1/3 portion of door area etc complete. The rate includes
cost of all materials, labour, hire of tools & machineries, as per
specifications.

39.9 Providing, fabricating and fixing partition frame work consisting of 50mm
x 50mm sal wood frame work at spacing not exceeding 600mm c/c fixed to
the bottom and ceiling, the partition shall be skinned on both sides using
12mm thick commercial plywood of approved brand termite and water
resistance, and top covered with 4mm thick approved quality veneer Sqm 15414.00
finished with melamine polish, complete including cost and conveyance of
all materials, labour for all items of work, HOM of equipment as per
specification. (P.No. 312, I.No. 39.9 of PWD SR 2015-16)

39.10 Removing wall paneling / false ceiling / wooden partition / aluminium


partition, stacking it with all cost and conveyance labour for all items of
work, HOM of equipment etc., complete as per specification. (P.No. 312, Sqm 55.00
I.No. 39.10 of CSR 2015-16)
39.11 Providing and fixing 100mm wide venitian blinds of window fashion fabric
of Taiwan make, with 50mm thick powder coated channel with balance,
imported, acrylic self alignable mechanism and equally placed spacers,
imported tilting mechanism for easy tilting operation,with nylon imported
thread and beadings, 100mm wide imported washable reusable fabric
placed with top hanger and bottom with 100mm long bottom plate
Sqm 900.00
connected to nylon imported bottom link chain. The rate is inclusive of
drilling holes for fixing channels to the wall, fixing threads and beadings
and link chains, hard ware fixtures etc., complete as per drawing,
specifications. (P.No. 312, I.No. 39.11 of CSR 2015-16)

39.12.1 Providing & Fixing of Mineral Fibre Suspended Ceiling System in the
module size of 600x600x19mm with Exposed grid.
The tiles should have Humidity Resistance (RH) of 99%, Light reflectance
87%, Thermal Conductivity k = 0.052-0.057 w/m K, NRC - 0.47, Colour
White, Fire Performance UK A2 S1, d0, with Anti Microbial coating on the
face of the tile, suitable for zone 4 area according to NF S 90-35:2003 with
cleanroom class of ISO 5 (Class 100), Decontamination Class of CP10 and
Bacteriological Cleanliness Class B1 for specific strains and reduction in
colony size. Washability properties of 500 wash cycles as per ASTM D-4828
and suitable for Green Building application with Recycled content of 37%. Sqm 2484.00
The tile shall be laid on 24mm wide T - section flanges colour white having
rotary stiching on all T sections i.e. the Main Runner, 1200mm & 600 mm
Cross tees with a web height of 38mm and a load carrying capacity of
15kgs/Sqm & pull out strength of minimum 100 Kgs. The T sections
should have a Galvanizing of 90 grams per Sqm and need to be installed
with Suspension system of approved make.

Page No. 325


39.12.2 Providing and supplying Acoustical Wall Panelling with square edges
made of fibre glass substrate 25mm thick and wrapped on the front side
with an acoustically transparent and classified for Fire reaction Class A, as
per ASTM E-84, fabric with option of colours - as per the choice of the
Architect/Engineer incharge of the size 600x600mm, 600x1200mm & Sqm 4660.00
600x1800mm providing a minimum sound absorption level of 0.85 NRC to
be affixed to wall using Wall panel Impalersand construction adhesives as
per the instructions laid down by the certified manufacturer.

Page 224 of 375


39.12.3 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling
System in the module size of 600x600x16mm with Exposed grid.

The tiles should have Humidity Resistance (RH) of 99%,


Light reflectance 87%, Thermal Conductivity k = 0.052-0.057 w/m K,
Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 & 7)
and suitable for green building application with recycled content of 30%. Sqm 1510.00
The tile shall be laid on 24mm wide T - section flanges colour white having
rotary stiching on all T sections i.e. the Main Runner, 1200mm & 600 mm
Cross tees with a web height of 38mm and a load carrying capacity of
15kgs/Sqm & pull out strength of minimum 100 Kgs. The T sections
should have a Galvanizing of 90 grams per Sqm and need to be installed
with Suspension system of approved make.
39.12.4 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling
System in the module size of 600x600x16mm with Exposed grid.

The tiles should have Humidity Resistance (RH) of 99%,


Light reflectance 83%, Thermal Conductivity k = 0.052-0.057 w/m K,
Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 & 7)
with sand texture finished Dune and suitable for green building application
with recycled content of 39%. Sqm 1646.00
The tile shall be laid on 24mm wide T - section flanges colour white
having rotary stiching on all T sections i.e. the Main Runner, 1200mm &
600 mm Cross tees with a web height of 38mm and a load carrying capacity
of 15kgs/Sqm & pull out strength of minimum 100 Kgs. The T sections
should have a Galvanizing of 90 grams per Sqm and need to be installed
with Suspension system of approved make.
Page No. 326
39.12.5 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling
System in the module size of 600x600x16mm with Exposed grid.

The tiles should have Humidity Resistance (RH) of 99%,


NRC 0.6, Light reflectance 87%, Thermal Conductivity k = 0.052-0.057
w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6
& 7) & Euroclass A2 S1, do and suitable for green building application with
recycled content of 50%. Sqm 1576.00
The tile shall be laid on 24mm wide T - section flanges colour white having
rotary stiching on all T sections i.e. the Main Runner, 1200mm & 600 mm
Cross tees with a web height of 38mm and a load carrying capacity of
15kgs/Sqm & pull out strength of minimum 100 Kgs. The T sections
should have a Galvanizing of 90 grams per Sqm and need to be installed
with Suspension system of approved make.
39.12.6 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling
System in the module size of 600x600x20mm with Exposed grid.

The tiles should have Humidity Resistance (RH) of 99%,


NRC 0.7, Light reflectance 85%, Thermal Conductivity k = 0.052-0.057
w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6
& 7) with sand texture finish and suitable for green building application
with recycled content of 47%. Sqm 1680.00
The tile shall be laid on 24mm wide T - section flanges colour white
having rotary stiching on all T sections i.e. the Main Runner, 1200mm &
600 mm Cross tees with a web height of 38mm and a load carrying capacity
of 15kgs/Sqm & pull out strength of minimum 100 Kgs. The T sections
should have a Galvanizing of 90 grams per Sqm and need to be installed
with Suspension system of approved make.
39.12.7 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling
System in the module size of 600x600x19mm with Exposed grid.

The tiles should have Humidity Resistance (RH) of 99%,


NRC 0.7, Light reflectance 85%, Thermal Conductivity k = 0.045-0.048
w/m K, Colour White, Fire Performance BS 476 Class 0 /Class 1 with
Durabrite scrim on the face of the tile and suitable for green building
application with recycled content of 27%. Sqm 2288.00
The tile shall be laid on 24mm wide T - section flanges
colour white having rotary stiching on all T sections i.e. the Main Runner,
1200mm & 600 mm Cross tees with a web height of 38mm and a load
carrying capacity of 15kgs/Sqm & pull out strength of minimum 100 Kgs.
The T sections should have a Galvanizing of 90 grams per Sqm and need to
be installed with Suspension system of approved make.
Page No. 327

Page 225 of 375


39.12.8 Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling
System in the module size of 600x600x15mm with Angled Tegular
Edge Tiles with Exposed grid.
The tiles should
have Humidity Resistance (RH) of 95%, NRC 0.9, Light reflectance 85%,
Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6&7) and
suitable for green building application with recycled content of 66% GW &
74% RW. The tile shall be Sqm 2074.00
laid on 24mm wide T - section flanges colour white having rotary stiching
on all T sections i.e. the Main Runner, 1200mm & 600 mm Cross tees with
a web height of 38mm and a load carrying capacity of 13.2kgs/Sqm & pull
out strength of minimum 100 Kgs. The T sections should have a
Galvanizing of 90 grams per Sqm and need to be installed with Suspension
system of approved make.
39.12.9 Providing and fixing true horizontal level suspended ceiling comprising of
GI Clip-in with double pip self-levelling feature and special tabs to allow
removal of tile to enable plenum access with plain visual consisting of
600x600mm clip in tiles of galvanised steel in 0.5 mm thickness with bevel Sqm 1882.00
edge in pre-coated Global white color with Light Reflectance> 75% and fire
performance of Class 1 as per BS 476 part 7

39.12.10 Providing and fixing true horizontal level suspended ceiling comprising of
GI Clip-in Standard Perforated metal ceiling consisting of 600x600mm
clip in tiles of galvanised steel in 0.5 mm thickness in Global white color
with Light Reflectance> 68%. The perforation shall be Standard Perforation
having hole diameter as 2.5mm and open area as 16%. The tiles shall have Sqm 2176.00
double pip self-levelling feature and special tabs to allow removal of tile to
enable plenum access. The tiles would have Fire Performance of Class 1 as
per BS 476 part 7 standard in module size of 600x600mm

39.12.11 Providing & Fixing of GI Lay in Plain metal ceiling in module size of
600x600 mm Lay-in tiles of pre-coated galvanised steel in 0.5 mm
thickness in Global white colour. The tiles would have fire performance of
Class 1 as per BS-476 part 7. Standard in module size of 600x600mm.
The tile shall be laid on
15mm wide T - section flanges colour white having rotary stiching on all T
Sqm 1790.00
sections i.e. the Main Runner, 1200mm & 600 mm Cross tees with a web
height of 38mm and a load carrying capacity of 12.5kgs/Sqm & pull out
strength of 100 Kgs. The T sections should have a Galvanizing of 90 grams
per Sqm and need to be installed with Suspension system of approved
make.

Page No. 328


39.12.12 Providing & Fixing of GI Lay-in Standard Perforated metal ceiling in
module size of 600x600 mm Lay-in tiles of pre-coated galvanised steel in
0.5 mm thickness in Global white colour. The perforation shall have
standard Perforation having hole diameter as 2.5mm and open area as
16%. The tiles would have fire performance of Class 1 as per BS-476 part 7
Standard. The tile shall be
laid on 15mm wide T - section flanges colour white having rotary stiching Sqm 2083.00
on all T sections i.e. the Main Runner, 1200mm & 600 mm Cross tees with
a web height of 38mm and a load carrying capacity of 12.5kgs/Sqm & pull
out strength of 100 Kgs. The T sections should have a Galvanizing of 90
grams per Sqm and need to be installed with Suspension system of
approved make.

39.12.13 Providing & Fixing of of Wooden finished Suspended Ceiling System


with WoodWorks edge tiles exposed grid. The Tile in
Plain/Perforated with approved laminate (Portland Malpe, Sea Beech, Siam
Wood & Mystique Walnut) finish with 0.7mm matching PVC edge banding
or with perforation of RD6006 (RD6) / RG3003 (RG3) / RG6011 (RG6) -
(either plain or perforation and pattern to be choosen) would have humidity
resistance (RH) of 70% in module size of 600x600x18mm and density of
725Kgs/m3. The tile shall be laid on 15mm wide T - section Sqm 5133.00
flanges colour white having rotary stiching on all T sections i.e. the Main
Runner, 1200mm & 600 mm Cross tees with a web height of 38mm and a
load carrying capacity of 12.5kgs/Sqm & pull out strength of 100 Kgs. The
T sections should have a Galvanizing of 90 grams per Sqm and need to be
installed with Suspension system of approved make.

Page 226 of 375


39.12.14 Providing & Fixing Channeled Woodworks perforated panels of width
192mm, thickness of 15mm and length 2400 mm or as required by the
Architect/approving engineer, made of a Moisture resistant fibre board with
minimum 595 Kg/m3 density substrte with a laminated facing as per the
approved shade & finish and a melamine balancing layer on the reverse
side. The boards shall have a special perforation pattern where the visible
surface has a "Helmholtz" fluted perforation of 3mm width and 5mm of
visible panel each. The edges of the panels shall be "tongue-and-grooved" to Sqm 4845.00
receive special clips for installation. The back of the perforated panel shall
have sound absorbing non-woven acoustical fleece having NRC of 0.63. The
panels shall be mounted on special aluminium splines (keel) using clips
provided and approved by the Engineer-in-Charge of work.

Page No. 329


39.12.15 Providing and fixing true horizontal level suspended ceiling comprising of
GI Clip-in with double pip self-levelling feature and special tabs to of
600x600mm clip in tiles of galvanised steel in 0.5 mm thickness with bevel
edge in white color. The tile shall be powder coated with dust repellant,
anti-microbial coating having light reflectance greater than 85%. The
coating will have resistance to fluorescence and UV-A as per ISO 4892-2 & Sqm 3506.00
ISO 16474-3 respectively. The coating also resist the mold growth as per
ASTM D3273. The tiles would have Fire Performance of Class A1 as per
BSEN 13823:2010+A1:2014 standard in module size of 600x600mm.

39.12.16 Providing and fixing true horizontal level suspended ceiling comprising of
GI Clip-in with double pip self-levelling feature and special tabs to allow
removal of tile to enable plenum access with plain visiual consisting of
600x600mm clip in tiles of galvanised steel in 0.5 mm thickness with bevel
edge in white color. The tile shall be powder coated with dust repellant,
anti-microbial coating having light reflectance greater than 85%. The
Sqm 4370.00
coating will have resistance to fluorescence and UV-A as per ISO 4892-2 &
ISO 16474-3 respectively. The coating also resist the mold growth as per
ASTM D3273. The tiles would have Fire Performance of Class A1 as per
BSEN 13823:2010+A1:2014 standard in module size of 600x600mm.

39.13 COURT HALL FURNITURE


39.13.1 COURT HALL FURNITURE DIAS for Judges Providing and fixing dias for
judges in court halls of overall size 3650 x 3050 x 600 mm using 40 x 40 x
2mm slotted angle for frame work at suitable intervals using double angle
back to back wherever necessary with suitable stiffeners for legs including
diagonal members fabricated using nuts and bolts, the top of the dias to be
covered with 25mm treated commercial block board of approved make,
seated and fastened properly by bolt and nut to the slotted angle frame
work, the sides of the dias to be covered with 12mm thick novopan sheet
fixed firmly to the slotted angle, including making a parapet alround the
dias to a height of 750mm using the slotted angle frame work and covered Sqm 7232.00
with novopan sheet of 12mm thick for outside and 4mm thick one side teak
plywood for inside of the parapet with 50x25mm sal wood frame work
attached to the slotted angle, the top of the parapet is fixed with 20mm teak
wood ornamental beeding alround including cost of all materials and
labour, painting, lead and lift and as per the direction of engineer-in-charge
of work. and also as per drawing appended.

Page No:330
39.13.2 COURT HALL FURNITURE Teak wood platform Providing and fixing
wooden platform of overall size 2450x1850x175mm using teak wood of
section 50x50mm of legs, 50x50mm for horizontals both at suitable
intervals from the point of view of stability, the top of the platform covered
with commercial block board of 25mm thick, all sides covered with 6mm
thick one side teak plywood fixed firmly to the platform including joining
Sqm 6300.00
the wooden sections properly using nails/screws, fevicol including cost of
wood, nails/screws, fevicol, cost of painting/polishing, labour, all lead and
lift, cost of any incidental charges etc., complete and as per the drawing
(appended) and direction of engineer-in-charge of work.

Page 227 of 375


39.13.3 COURT HALL FURNITURE Horse Shoe Table Providing and fixing “HORSE
SHOE TABLE” of overall size 4500 x 2200x 750mm using teak wood of size
100x100mm for legs at suitable intervals, 50x75mm section for horizontal
support at top, 50x100mm section horizontal support at bottom as shown
in figure. The top of the table which should be 600mm in width all along, is
covered with 19mm thick block board and 1.50mm thick formica sheet
fixed on top of the block board, all of approved make. The inside vertical
surface is covered with 6mm thick one side teak plywood, including
providing teak wood beeding alround the table for good aesthetic Sqm 9820.00
appearance, including joining the wooden sections properly using
nails/screws, fevicol including cost of wood, nails/screws, fevicol, cost of
painting/ polishing, labour, all lead and lift, cost of any incidental charges
etc., complete and as per the drawing (appended) and direction of
engineerin- charge of work. (P.No. 315/I.No. 39.13.3 of CSR 2015-16)

39.13.4 COURT HALL FURNITURE Teak wood witness box Providing and
fixing witness box of overall size 1200x750x1350mm with one side door way
as shown in figure using teak wood of size 75x75mm for legs, 50x75mm
size for horizontal support at top and bottom, and 25x50mm size section for
verticals between legs with a spacing of 150mm including fixing 19mm
thick commercial block board for full area at bottom and for a length of
300mm at top to facilitate keeping the file during the course of witness each 24730.00
including joining the wooden sections properly using nails/screws, fevicol
including cost of wood, nails/screws, fevicol, cost of painting/polishing,
labour, all lead and lift, cost of any incidental charges etc., complete and as
per the drawing (appended) and direction of engineer-in-charge of work.

Page No. 331


39.13.5 COURT HALL FURNITURE Teak wood Accused box Providing and
fixing accused box of overall size 3000x1150x1350mm with one side door
way as shown in figure using teak wood of size 75x75mm for legs,
50x75mm size for horizontals at top and bottom and 25x50mm size for
verticals between legs with a spacing of 150mm including fixing 19mm
thick commercial board for full area at bottom, including joining the
wooden sections properly using nails/screws, fevicol including cost of wood, each 37500.00
nails/screws, hinges, locking arrangements for the opening, fevicol, cost of
painting/polishing, labour, all lead and lift, cost of any incidental charges
etc., complete and as per the drawings (appended) direction of engineer-in-
charge of work.

39.14 STRAIGHT WORKSTATION (Frame and separator) Providing


and fixing STRAIGHT WORKSTATION consisting of back to back unit made
out of 75 mm thick MS CRCA powder coated ,tile based system for main
sprine, Separator 25 mm tghick PLPB - BSL wooden separator for return
spine,Top tile finish 8 mm thick MDF covered with Fabric of approved
colour and one writing board ( 600 mmw) and one soft board ( 600 mmw )
per workstation,Bottom tile finish 9 mm thick Laminate tile of approved
colour, Raceway- one middle raceway ( 600mmW ) below table top per
workstation and continous raceway at the skirting level,Wir e manager-
ABS plastic grommet one number per table,Table top - 25 mm thick PLPB
with straight table top Hardware_ MS powder coated corner bkt,cantilever
bkt,separator hook on bkt, L bkt and Table joint plate., as per specifications
, drawings and as directed by Engineer in charge

39.14.1 Sharing workstation 1A ) Size : 1200 mmW x 600mm D x 1200 mm ht -


No 18030.00
(Sharing - Edge binding table top): Back to Back (set of 2)
39.14.2 Sharing workstation 1B ) Size : 1200 mmW x 540mm D x 1200 mm ht -
No 17410.00
(Sharing-Post formed table top): Back to Back (set of 2)
39.14.3 Non Sharing workstation 1C) Size : 1200 mmW x 600mm D x 1200 mm ht
No 11830.00
(Non Sharing-Edge binding table top): single unit
39.14.4 Non Sharing workstation 1D ) Size : 1200 mmW x 540mm D x 1200 mm
No 12990.00
ht (Non Sharing-Post formed table top) single unit
Page No. 332

Page 228 of 375


39.15 STRAIGHT WORKSTATION (Frame): Providing and fixing STRAIGHT
WORKSTATION ( Frame ) consisting of back to back unit made out of 75
mm thick MS CRCA powder coated, tile based system for main and return
spine, Top tile finish 8 mm thick MDF covered with Fabric of approved
colour and one writing board (600 mm w) and one soft board ( 600 mmw )
per workstation,Bottom tile finish 9 mm thick Laminate tile of approved
colour, Raceway- one middle raceway ( 600mmW ) below table top per
workstation and continous raceway at the skirting level, Wire manager-
ABS plastic grommet one number per table,Table top - 25 mm thick PLPB
with straight table top End Table 25 mm thick PLPB with straightedge
bound Hardware-MS powder coated corner bkt,cantilever bkt,separator
hook on bkt, L bkt and Table joint plate., as per specifications , drawings
and as directed by Engineer in charge Sharing workstation. (P.No. 317,
I.No. 39.15.2 of PWD SR 2015-16)

39.15.1 Sharing workstation 2A ) Size : 1200 mmW x 600mm D x 1200 mm ht -


No 21820.00
(Sharing - Edgebinding table top): Back to Back (set of 2)
39.15.2 Sharing workstation 2B ) Size : 1200 mmW x 540mm D x 1200 mm ht -
No 22760.00
(Sharing-Postformed table top): Back to Back (set of 2)
39.15.3 Non Sharing workstation 2C) Size : 1200 mmW x 600mm D x 1200 mm ht
No 14340.00
(Non Sharing-Edgebinding table top): single unit
39.15.4 Non Sharing workstation 2D ) Size : 1200 mmW x 540mm D x 1200 mm
No 14950.00
ht (Non Sharing-Postformed table top): single unit
39.16 CUBICLE WORKSTATIONS : Providing and fixing CUBICLE
WORKSTATIONS consisting of wings made out of 75 mm thick MS CRCA
powder coated ,tile based system for main and return spine, Top tile finish
8 mm thick MDF covered with Fabric of approved colour and one writing
board (600 mm w) and one soft board (600 mmw) per workstation, Bottom
tile finish 9 mm thick Laminate tile of approved colour, Raceway- one
middle raceway (600mmW) below table top per workstation and continous
raceway at the skirting level, Wire manager- ABS plastic grommet one
number per table,Table top - 25 mm thick PLPB with straight table top End
Table 25 mm thick PLPB with straightedge bound Hardware-MS powder
coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and Table
joint plate., as per specifications , drawings and as directed by Engineer in
charge. (P.No. 318, I.No. 39.16.2 of PWD SR 2015-16)

39.16.1 X TYPE 4 wings 3A) Size : 1500 mmW x 1200mm D x 1200 mm ht : Unit 50000.00
39.16.2 X TYPE 4 wings 3B) Size : 1500 mmW x 1500mm D x 1200 mm ht: Unit 62000.00
39.16.3 T TYPE 2 wings 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht Unit 32000.00
Page No.333
39.16.4 T TYPE 2 wings 3D) Size : 1500 mmW x 1500mm D x 1200 mm ht : Unit 47300.00
39.16.5 C TYPE 2 wings 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht: Unit 34900.00
39.16.6 C TYPE 2 wings 3D) Size : 1500 mmW x 1500mm D x 1200 mm ht: Unit 51600.00
39.16.7 L TYPE one wing 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht: Unit 21000.00
39.16.8 L TYPE one wing 3D) Size : 1500 mmW x 1500mm D x 1200 mm ht: Unit 23390.00
39.17 FREE STANDING TABLE FOR CABIN - WITHOUT FRAMES Providing and
fixing Free Standing Table for Cabin- without frames consisting of 25 mm
thick PLPB table top , 25 mm thick PLPB with edge bomded End table,18
mm thick PLPB with edge bonded Modesty, Wire manager -ABS plastic
grommet one number per table Hardware-Minifix assembly and screw leg.,
as per specifications, drawings and as directed by Engineer in charge

39.17.1 Main Table : 1500 mmW x 750mm D x 750 mm ht (Edgebinding table top)
Side Table : 900 mm W x 450mm D X 750 mm ht. (P.No. 318/ I.No. 39.17.1 No 11960.00
of CSR 2015-16)
39.17.2 Main Table : 1500 mmW x 750mm D x 750 mm ht (Post formed table top)
No 10700.00
Side Table : 900 mm W x 450mm D X 750 mm ht
39.18 FREE STANDING TABLE FOR CABIN - WITHOUT FRAMES Providing and
fixing Free Standing Table for Cabin- without frames consisting of 25 mm
thick PLPB table top , 25 mm thick PLPB with edge bonded End table,18
mm thick PLPB with edge bonded Modesty, Wire manager -ABS plastic
grommet one number per table Hardware-Minifix assembly and screw leg.,
as per specifications, drawings and as directed by Engineer in charge

39.18.1 1200 mmW x 600mm D x 750 mm ht (Edgebinding table top) No 7010.00


39.18.2 1500 mmW x 600mm D x 750 mm ht (Edgebinding table top) No 7850.00
39.18.3 1200 mmW x 540mm D x 750 mm ht (Post formed table top No 7294.00
39.18.4 1500 mmW x 540mm D x 750 mm ht (Post formed table top) No 7544.00
Page No. 334

Page 229 of 375


39.19 Discussion table - wooden Providing and fixing discussion table wooden
consisting of 25 mm thick PLPB table top edge bounded, 25 mm thick PLPB
with edge bonded End table, Hardware-Minifix assembly and screw leg., as
per specifications, drawings and as directed by Engineer in charge

39.19.1 600 mm Dia X 750 mm Ht ( 4 seater ) No 4240.00


39.19.2 750 mm Dia X 750 mm Ht ( 4 seater ) No 5200.00
39.19.3 900 mm Dia X 750 mm Ht ( 4 seater ) No 5750.00
39.20 Discussion table - Metal leg Providing and fixing discussion table metal
leg consisting of 25 mm thick PLPB table top edge bounded MS CRCA sheet
round plate at bottom and 75 mm dia pol at centre with 25 X 25 tube
welded at top Hardware-L bkt and screw leg ., as per specifications,
drawings and as directed by Engineer in charge
39.20.1 600 mm Dia X 750 mm Ht ( 4 seater ) No 6690.00
39.20.2 750 mm Dia X 750 mm Ht ( 4 seater ) No 8920.00
39.20.3 900 mm Dia X 750 mm Ht ( 4 seater ) No 9375.00
39.21 Meeting table -wooden : Providing and fixing meeting table consisting of
25 mm thick PLPB table topedge bounded, 25 mm thick PLPB with edge
bonded End table,18 mm thick PLPB with edge bonded Modesty, Hardware-
Minifix assembly and screw leg., as per specifications, drawings and as
directed by Engineer in charge
39.21.1 1500 mm Dia X900 mm D X 750 mm Ht (6 seater) No 12050.00
39.21.2 2400 mm Dia X1200 mm D X 750 mm Ht (12 seater) No 20000.00
39.22 Providing and fixing conference table consisting of 25 mm thick PLPB table
top edge bounded, 25 mm thick PLPB with edge bonded End table,18 mm
thick PLPB with edge bonded Modesty, Hardware-Minifix assembly and
screw leg., as per specifications, drawings and as directed by Engineer in Rmt 63800.00
charge 4800 mmX 2400mm X 750 mm Ht (20 seater) - U shaped with a top
width of 600 mm. (P.No. 320, I.No. 39.22 of CSR 2015-16)

39.23.1 Modular Partition: Providing and fixing modular partition consisting of


75mm thick MS CRCA frames powder coated, tile based system frame,
8mm thick MDF covered with Fabric of approved colour for Top file finish,
5mm thick clear ordinary glass both side Middle tile finish, or 8mm thick
MDF covered with Fabric of approved colour for Middle tile finish, 9mm
thick Laminate tile of approved colour for Botom tile finish, Continuous Sqm 4800.00
skirting level raceway will be provided. as per specifications, drawings and
as directed by Engineer in charge. 75mm thick frames tile based system
(Frame with Tile). (P.No. 320, I.No. 39.23.1 of PWD SR 2015-16)

39.23.2 Modular Partition: Providing and fixing modular partition consisting of


75mm thick MS CRCA frames powder coated, tile based system frame,
8mm thick MDF covered with Fabric of approved colour for Top file finish,
5mm thick clear ordinary glass both side Middle tile finish, or 8mm thick
MDF covered with Fabric of approved colour for Middle tile finish, 9mm
thick Laminate tile of approved colour for Botom tile finish, Continuous Sqm 5268.00
skirting level raceway will be provided. as per specifications, drawings and
as directed by Engineer in charge. 75mm thick frames tile based system
(Frame with Glass). (P.No. 320, I.No. 39.23.2 of PWD SR 2015-16)

Page No. 335


39.24 Storage Unit - wooden - One side laminate: Providing and fixing woode
storage unit one side laminate with 18 mm PLY/PLPB with edge bound for
body, 18mm PLY/PLPB with openable shutters and individual locking
system for shutter, 9 mm PLY with edge bound for rear portion with Hafele
fitting hinges, Hafele locks,Minifix assembly, screw legs, Handles and tower
bolt. complete as per specifications, drawings and as directed by Engineer
in charge

39.24.1 PLY STORAGE 900 mm W X 430 mm D X 750 mm No 6964.00


39.24.2 PLY STORAGE 900 mm W X 430 mm D X 1200 mm No 10000.00
39.24.3 PLY STORAGE 900 mm W X 430 mm D X 2100 mm Ht No 17678.00
39.24.4 PLPB STORAGE 900 mm W X 430 mm D X 750 mm Ht No 6830.00
39.24.5 PLPB STORAGE 900 mm W X 430 mm D X 1200 mm Ht No 9820.00
39.24.6 PLPB STORAGE 900 mm W X 430 mm D X 2100 mm Ht No 16960.00
39.25 Mobile pedestal unit- WOODEN : Providing and fixing 450mmw X 450
mmd X 685 mmht ) Mobile pedestal unit-WOODEN with 18mm thick PLPB
with edge bonded for body, Two equal drawer and filing drawer with
centralized locking system, Telescopic channels, castors, Handles and lock No 4900.00
etc., complete as per specifications, drawings and as directed by Engineer
in charge. (P.No. 320, I.No. 39.25 of SR 2015-16)

Page 230 of 375


39.26 Mobile pedestal unit- METAL: Providing and fixing 450mmw X 450 mmd
X 685 mmht ) Mobile pedestal unit- Metal with MS CRCA sheet powder
coated for body, Two equal drawer and one filing drawer with centralized
locking system, Telescopic channels, castors, Handles and lock etc., No 6250.00
complete as per specifications, drawings and as directed by Engineer in
charge.

39.27 Mobile pedestal unit- METAL with wooden facia : Providing and fixing
450mmw X 450 mmd X 685 mmht ) Mobile pedestal unit- Metal with
wooden facia made of MS CRCA sheet powder coated for body, 18 mm thick
PLPB with edge bonded facia, Two equal drawer and one filing drawer with No 5800.00
centralized locking system, Telescopic channels, castors, Handles and lock
etc., complete as per specifications, drawings and as directed by Engineer
in charge

Note : The Rate for the items 39.14.1,39.14.2, 39.15.1, 39.15.2, 39.16.1, 39.16.2,
39.16.3, 39.16.4, 39.16.5 & 39.16.6, are for the complete unit as per the
drawing appended
Page No. 336

40.0 40.FIRE FIGHTING WORK


40.1 Providing ABC Powder based MAP 50, 1Kg
Providing 1kg Fire Extinguisher Mono Ammonium Phosphate Powder
50, Stored Pressure Type, Pressure Gauge, Gross Weight 2.3 Kg, empty
weight 1.3 Kg, Can Height 298MM, Diameter 86.50MM, Discharge Time
less than 8 Secs, Controllable discharge mechanism (Squeeze grip with easy
snap safety seal), Range minimum 2 meters, applicable on Class A,B,C and
electrically started Fire, A Rating 1A, B Rating 8B, Can construction : Deep each 2298.00
drawn & Co., Mig welded, valve Construciton :Forging and Mechining,
Internal Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, 5 years
Warranty with instalert system etc., complete

40.2 Providing ABC Powder based MAP 50, 2Kg


Providing 2kg Fire Extinguisher Mono Ammonium Phosphate
Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight
3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM,
Discharge Time less than 8 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 2 meters,
applicable on Class A,B,C and electrically started Fire, A Rating 1A, B
Rating 8B, Can construction : Deep drawn & Co., Mig welded, valve each 3447.00
Construciton : Forging and Mechining, Internal Coating of Can: Epoxy
powder coating, External Coating of Can: Epoxy Polyster power coating,
Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete.

40.3 Providing ABC Powder based MAP 50, 4Kg


Providing 4kg Fire Extinguisher Mono Ammonium Phosphate Powder 50,
Stored Pressure Type, Pressure Gauge, Gross Weight 6.9 Kg, empty weight
2.9 Kg, Can Height 440MM, Diameter 140MM, Discharge Time less than 13
Secs, Controllable discharge mechanism (Squeeze grip with easy snap
safety seal), Range minimum 4 meters, applicable on Class A,B,C and
electrically started Fire, A Rating 2A, B Rating 21B, Can construction :
Deep drawn & Co.,Mig welded, valve Construciton : Forging and Mechining, each 4788.00
Internal Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, Helium Leak
Detection Tested, ISI and EN Approved, 5 years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

40.4 Providing ABC Powder based MAP 50, 6Kg


Providing 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 50,
Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight
3.5 Kg, Can Height 435MM, Diameter 160MM,Discharge Time less than 9
Secs, Controllable discharge mechanism (Squeeze grip with easy snap
safety seal), Range minimum 4 meters, applicable on Class A,B,C and
electrically started Fire, A Rating 3A, B Rating 21B, Can construction :
Deep drawn & Co., Mig welded, valve Construciton : Forging and each 5819.00
Mechining, Internal Coatingof Can: Epoxy powder coating, External Coating
of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM,
Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 345

Page 231 of 375


40.5 Providing ABC Powder based MAP 50, 9Kg
Providing 9kg Fire Extinguisher Mono Ammonium Phosphate Powder 50,
Stored Pressure Type, Pressure Gauge, Gross Weight 14.90 Kg, empty
weight 5.90 Kg, Can Height 615MM, Diameter 175MM, Discharge Time less
than 13Secs, Controllable discharge mechanism (Squeeze grip with easy
snap safety seal), Range minimum 4 meters, applicable on Class A,B,C and
electrically started Fire, A Rating 4A, B Rating 34B, Can construction :
Deep drawn & Co., Mig welded, valve Construciton : Forging and each 7661.00
Mechining, Internal Coating of Can: Epoxy powder coating, External
Coating of Can: Epoxy Polyster power coating, Sheet metal thickness:
2.00MM, Helium Leak Detection Tested, ISI and EN Approved, 5 years
Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

40.6 Providing ABC Powder based MAP 90, 2Kg


Providing 2 kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight
3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM,
Discharge Time less than 8 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 2 meters,
applicable on Class A,B,C and electrically started Fire, A Rating 1A, B
Rating 8B, Can construction : Deep drawn & Co., Mig welded, valve
Construciton : Forging and Mechining, Internal Coating of Can: Epoxy each 4420.00
powder coating, External Coating of Can: Epoxy Polyster power coating,
Sheet metal thickness: 1.60MM, Helium Leak Detection Tested, ISI and EN
Approved, 5 years Warranty with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete

40.7 Providing ABC Powder based MAP 90, 4Kg


Providing 4kg Fire Extinguisher Mono Ammonium Phosphate
Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight
6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM,
Discharge Time less than 13 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 2A, B Rating 21B, Can construction : Deep drawn & Co., Mig
welded, valve Construciton : Forging and Mechining, Internal Coating
each 6188.00
of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 1.60MM, Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system with
Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 346


40.8 Providing ABC Powder based MAP 90, 6Kg
Providing 6kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight9.40 Kg,
empty weight 3.4 Kg, Can Height 480MM, Diameter
160MM, Discharge Time less than 13 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 3A, B Rating 21B, Can construction : Deep drawn & Co.,
Mig welded, valve Construciton : Forging and Mechining, Internal Coating each 7661.00
of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 1.60MM, Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

Page 232 of 375


40.9 Providing ABC Powder based MAP 90, 9Kg
Providing 9kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight
14.9 Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter
175MM, Discharge Time less than 13Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 4A, B Rating 34B, Can construction : Deep drawn & Co.,
Mig welded, valve Construciton : Forging and Mechining, Internal Coating each 12571.00
of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 2.00 MM, Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.10 Providing ABC Powder based MAP 90, 25Kg Providing 25kg Fire
Extinguisher Mono Ammonium Phosphate Powder 90, Stored Pressure
Type, Pressure Gauge, Gross Weight 76Kg, empty weight 51 Kg, Can Height
1200 MM, Diameter 300 MM, Discharge Time less than 30 Secs,
Controllable discharge mechanism (Squeeze grip with easy snap safety
seal), Range minimum 6 meters, applicable on Class A,B,C and electrically
started Fire, Can construction : Deep drawn & Co., Mig welded, valve each 29464.00
Construciton: Forging and Mechining,
Internal Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 4.00 MM, 1 year
Warranty. with instalert system with Superior quality EPDM Rubber
Hosepipe etc., complete

Page No. 347


40.11 Providing Ceiling mounted 5 Kg
Providing 5kg Fire Extinguisher Mono Ammonium Phosphate Powder
90, Stored Pressure Type, Pressure Gauge, Gross Weight 7.7Kg,
empty weight 2.7 Kg, Can Height 264 MM, Diameter 240 MM,
Discharge Time less than 8 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 10 meters,
applicable on Class A,B,C and electrically started Fire, Can construction
: Deep drawn & Co., Mig welded, valve Construciton : Forging and each 10803.00
Mechining, Internal Coating of Can: Epoxy powder coating, External
Coating of Can: Epoxy Polyster power coating, Sheet metal thickness:
2.00 MM, Helium Leak Detection Tested, 5 years warranty. etc., complete

40.12 Providing 10Kg Ceiling Mounted


Providing 10kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight
14.8Kg, empty weight 4.8 Kg, Can Height 320 MM, Diameter 300 MM,
Discharge Time less than 10 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 10
meters, applicable on Class A,B,C and electrically started Fire, Can
construction : Deep drawn & Co., Mig welded, valve Construciton : Forging each 16597.00
and Mechining, Internal Coating of Can: Epoxy powder coating, External
Coating of Can: Epoxy Polyster power coating, Sheet metal thickness:
2.00 MM, Helium Leak Detection Tested, 5 years warranty. etc., complete

40.13 Providing 1 Kg Fire Extinguisher Monnex powder


Providing 1kg Stored Pressure Type, Pressure Guage, Gross
Weight 2.7 Kg, empty weight 1.7 Kg, Can Height 344 MM, Diameter
108MM, Discharge Time less than 8 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, applicable on Class A,B and electrically started
Fire, B Rating 89B, Can construction : Deep drawn & Co., Mig each 5304.00
welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 1.60 MM,
5 years warranty.with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

Page 233 of 375


40.14 Providing 2 Kg Fire Extinguisher Monnex powder
Providing 2kg Stored Pressure Type, Pressure Guage, Gross Weight
4.9 Kg, empty weight 2.9 Kg, Can Height 440 MM, Diameter 140 MM,
Discharge Time less than 9 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 4 meters,
applicable on Class A,B and electrically started Fire, Very effective on
Class B Fire, B Rating 144B, Can construction : Deep drawn & Co., Mig
welded, valve Construciton : Forging and Mechining, Internal Coating of
Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster each 8250.00
power coating, Sheet metal thickness: 1.60 MM, 5 years warranty. with
instalert system with Superior quality EPDM Rubber Hosepipe etc.,
complete

Page No. 348


40.15 Providing 4 Kg Fire Extinguisher Monnex powder
Providing 4kg Stored Pressure Type, Pressure Guage, Gross
Weight 7.4Kg, empty weight 3.4 Kg, Can Height 480 MM, Diameter
160 MM, Discharge Time less than 13 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, Can construction : Deep drawn & Co., Mig
each 13848.00
welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 1.60 MM,
5 years warranty. with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.16 Providing 4 Kg Fire Extinguisher for Lite metal fires SPM-TEC


Providing 4kg SPM-TEC Powder Based stored presure type melting
point at 600-650 degree C, Applicable on Class D metal fires in
Magnesium, Aluminium, Zinc, Sodium Potassium, Francium, Lithium,
Cesium, Pressure Guage, Gross weight Gross Weight 6.9Kg, empty
weight 2.9 Kg, Can Height 440 MM, Diameter 140 MM, Discharge
Time less than 15 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 4 meters,
Can construction : Deep drawn & Co., Mig welded, valve Construciton each 10607.00
: Forging and Mechining, Internal Coating of Can: Epoxy powder
coating, External Coating of Can: Epoxy Polyster power coating,
Sheet metal thickness: 1.60 MM, helium leak detection tested,
EN approved, 5 years warranty with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete

40.17 Providing 6 Kg Fire Extinguisher for Lite metal fires SPM-TEC


Providing 6kg SPM-TEC Powder Based stored presure type melting
point at 600-650 degree C, Applicable on Class D metal fires in
Magnesium, Aluminium, Zinc, Sodium Potassium, Francium, Lithium,
Cesium, Pressure Guage, Gross weight Gross Weight 9.4Kg, empty
weight 3.4 Kg, Can Height 480 MM, Diameter 160 MM, Discharge
Time less than 16 Secs, Controllable discharge mechanism (Squeeze
grip with easy snap safety seal), Range minimum 4 meters, Can each 14732.00
construction : Deep drawn & Co., Mig welded, valve Construciton
: Forging and Mechining, Internal Coating of Can: Epoxy powder
coating, External Coating of Can: Epoxy Polyster power coating,
Sheet metal thickness: 1.60 MM, helium leak detection tested,
EN approved, 5 years warranty. with instalert system with Superior
quality EPDM Rubber Hosepipe etc., complete

Page No. 349

Page 234 of 375


40.18 Providing 9 Kg Fire Extinguisher for Lite metal fires SPM-TEC
Providing 9kg SPM-TEC Powder Based stored presure type melting point
at 600-650 degree C, Applicable on Class D metal fires in Magnesium,
Aluminium, Zinc, Sodium Potassium, Francium, Lithium, Cesium, Pressure
Guage, Gross weight Gross Weight 14.9Kg, empty weight 5.9 Kg, Can
Height
615 MM, Diameter 175 MM, Discharge Time less than 18 Secs, Controllable
discharge mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, Can construction : Deep drawn & Co., Mig welded,
valve Construciton : Forging and Mechining, Internal Coating of Can:
Epoxy powder coating, External Coating of Can: Epoxy Polyster power
coating, Sheet metal thickness: 2.00 MM, helium leak detection tested, each 20625.00
EN approved, 5 years warranty with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete

40.19 Providing 4 Kg Fire Extinguisher for Heavy metal fires SPM-PYRO


Providing 4 Kg Powder Based stored presure type melting
point at 1200 degree C, Applicable on Class D metal fires in
heavy metals, alkali metals and alloys Pressure Guage, Gross
weight Gross Weight 6.9Kg, empty weight 2.9 Kg, Can Height
440 MM, Diameter 140 MM, Discharge Time less than 15 Secs,Controllable
discharge mechanism (Squeeze grip with easy snap safety
seal), Range minimum 4 meters, Can construction : Deep drawn & each 23571.00
Co., Mig welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy
Polyster power coating, Sheet metal thickness: 1.60 MM, helium leak
detection tested, EN approved, 5 years warranty.complete

40.20 Providing 6Kg Fire Extinguisher for Heavy metal fires SPM-PYRO
Providing 6Kg Powder Based stored presure type melting point at 1200
degree C, Applicable on Class D metal fires in heavy metals, alkali metals
and alloys Pressure Guage, Gross weight Gross Weight 9.4Kg, empty
weight 3.4 Kg, Can Height 480MM, Diameter 160 MM, Discharge Time
less than 16 Secs, Controllable discharge mechanism (Squeeze grip
with easy snap safety seal), Range minimum 4 meters, Can construction
: Deep drawn & Co., Mig welded, valve Construciton : Forging and
Mechining, Internal Coating of Can: Epoxy powder coating, External
Coating
each 35357.00
of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60 MM,
helium leak detection tested, EN approved, 5 years warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

40.21 Providing 9 Kg Fire Extinguisher for Heavy metal fires, SPM-PYRO


Providing 9Kg Powder Based stored presure type melting point
at 1200 degree C, Applicable on Class D metal fires in heavy
metals, alkali metals and alloys Pressure Guage, Gross Weight
14.9Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter
175 MM, Discharge Time less than 18 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, Can construction : Deep drawn & Co., Mig welded,
valve Construciton : Forging and Mechining, Internal Coating of each 53036.00
Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 2.00 MM, helium leak detection
tested, EN approved, 5 years warranty with instalert system with Superior
quality EPDM Rubber Hosepipe etc., complete

Page No. 350

Page 235 of 375


40.22 Providing 2Kg Fire Extinguisher Clean Agent HCFC 123
Providing 2Kg Pressure type, Pressure Guage, Gross Weight 3.7Kg,
empty weight 1.7 Kg, Can Height 344MM, Diameter 108 MM, Discharge
Time less than 8 Secs, Controllable discharge mechanism (Squeeze
grip with easy snap safety seal), Range minimum 2 meters, applicable on
Class A,B,C and electrically started Fire, B Rating 21B, Can construction :
Deep drawn & Co., Mig welded, valve Construciton : Forging and
Mechining,
Internal Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 2.00 MM, helium
each 16205.00
leak detection tested, EN approved, 5 years warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.23 Providing 4 Kg Fire Extinguisher Clean Agent HCFC 123


Providing 4Kg Stored Pressure Type, Pressure Gauge, Gross Weight
6.9 kg empty weight 2.9 kg Can Height 440MM, Diameter 140 MM,
Discharge minium 9 Secs, Controllable discharge mechanism (Squeezegrip
with easy snap safety seal), Range minimum 4 Meters, applicable
on Class A,B,C and electrically started Fire, A Rating 1A, B Rating
13B Can Construction; Deep drawn & CO, Mig welded, Valve Construction:
Forging & Machining, Internal Coating of Can : Epoxy Powder coating, each 32213.00
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, EN Approved,
5 years warranty with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.24 Providing 6 Kg Fire Extinguisher Clean Agent HCFC 123


Providing 6Kg Stored Pressure Type, Pressure Gauge, Gross Weight
9.4kg. empty weight 3.4 kg Can Height 480MM, Diameter 160 MM,
Discharge Time less than 13 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 4 Meters,
applicable on Class A,B,C and electrically started Fire, A Rating 2A,
B Rating 21B Can Construction; Deep drawn & CO, Mig welded, Valve
Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder
coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet each 45571.00
metal thickness: 1.60MM, Helium Leak Detection Tested, EN Approved,
5 years warranty with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

Page No. 351


40.25 Providing 5Kg Ceiling Mounted Fire Extinguisher Clean Agent
HCFC 123
Providing 5Kg Stored Pressure Type, Pressure Gouge, Gross Weight
7.7kg. empty weight 2.7 kg Can Height 267MM, Diameter 230 MM,
Discharge Time less than 8Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction: each 41838.00
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, 5 Years Warranty

40.26 Providing 10Kg Ceiling Mounted Fire Extinguisher Clean Agent


HCFC 123
Providing 10Kg Stored Pressure Type, Pressure Gouge, Gross Weight
14.8kg. empty weight 4.8 kg Can Height 316MM, Diameter 300 MM,
Discharge Time less than 10Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction: each 66785.00
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 2.0MM, Helium Leak Detection Tested, 5 Years Warranty

Page 236 of 375


40.27 Providing 2Kg Fire Extinugisher Clean Agent FE36 Dupont
Providing 2Kg Stored Pressure Type, Pressure Gauge, Gross Weight
3.70kg. empty weight 1.7 kg Can Height 344MM, Diameter 108 MM,
Discharge Time minimum 8 Secs, Controlable discharge mechanism,
Range minimum 2 Meters, applicable on Class A,B,C and electrically
started Fire B, Rating 8B, Can Construction; Deep drawn & CO,Mig welded,
Valve Construction: Forging & Machining, Internal Coating of Can
: Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder
coating, Sheet metal thickness: 1.60MM, Helium Leak Detection Tested, each 23079.00
5 Years Warranty with instalert system with Superior quality EPDM Rubber
Hosepipe etc., complete

40.28 Providing 4Kg Fire Extinugisher Clean Agent FE36, Dupont


Providing 4Kg Stored Pressure Type, Pressure Gauge, Gross Weight
6.9kg. empty weight 2.9 kg Can Height 440MM, Diameter 140 MM,
Discharge Time minimum 13 Secs, Controlable discharge mechanism,
Range minimum 4 Meters, applicable on Class A,B,C and electrically
started Fire A, Rating 1A, B, Ranting 13B, Can Construction; Deep
drawn & CO, Mig welded, Valve Construction: Forging & Machining, each 40758.00
Internal Coating of Can : Epoxy Powder coating, External Coating of
Can : Epoxy Polyster Powder coating, Sheet metal thickness: 1.60MM,
Helium Leak Detection Tested, 5 Years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 346


40.29 Providing 6Kg Fire Extinugisher Clean Agent FE36, Zeri ODP
Providing 6Kg Stored Pressure Type, Pressure Gauge, Gross Weight
9.4kg. empty weight 3.4 kg Can Height 480MM, Diameter 160 MM,
Discharge Time minimum 13 Secs, Controlable discharge mechanism,
Range minimum 4 Meters, applicable on Class A,B,C and electrically
started Fire A Rating 5A, B, Ranting 34B, Can Construction; Deep
drawn & CO, Mig welded, Valve Construction: Forging & Machining, each 66490.00
Internal Coating of Can : Epoxy Powder coating, External Coating of
Can : Epoxy Polyster Powder coating, Sheet metal thickness: 1.60MM,
Helium Leak Detection Tested, 5 Years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.30 Providing 9Kg Fire Extinugisher Clean Agent FE36, Zeri ODP
Providing 9Kg Stored Pressure Type, Pressure Gauge, Gross Weight
13.8kg. empty weight 4.8 kg Can Height 611MM, Diameter 175 MM,
Discharge Time minimum 12 Secs, Controlable discharge mechanism,
Range minimum 4 Meters, applicable on Class A,B,C and electrically
started Fire, Can Construction; Deep drawn & CO, Mig welded, Valve
Construction: Forging & Machining, Internal Coating of Can : Epoxy each 44196.00
Powder coating, External Coating of Can : Epoxy Polyster Powder
coating, Sheet metal thickness: 1.60MM, Helium Leak Detection Tested,
5 Years Warranty

40.31 Providing 5Kg Ceiling Mounted Fire Extinugisher Clean Agent


FE36, Zeri ODP
Providing 5Kg Stored Pressure Type, Pressure Gauge, Gross Weight
7.7kg. empty weight 2.7kg Can Height 267MM, Diameter 230 MM,
Discharge Time less than 8 Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction: each 54017.00
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, 5 Years Warranty

Page 237 of 375


40.32 Providing 10Kg Ceiling Mounted Fire Extinugisher Clean Agent
FE36, Zeri ODP
Providing 10Kg Stored Pressure Type, Pressure Gauge, Gross Weight
14.8kg. empty weight 4.8kg Can Height 316MM, Diameter 300 MM,
Discharge Time less than 8 Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction: each 54214.00
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, 5 Years Warranty

Page No. 353


40.33 CO2 2Kg Squeeze grip
Providing 2 Kg CO2 Gas Type Fire Extinugisher Squeeze grip type,
used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty
Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time
less than 8 Secs, Controllable discharge mechanism, Applicable on
Class B&C Fire, B Rating 8B, Can Construction : Hot spinning/Forging,
Valve Construction : Forging & Machining, Internal Coating of Can : each 11097.00
Not Applicable, External coating of Can : Spray Painting, Sheet metal
thickness : 4.0MM ISI Approved, 1 Year Warranty.with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.34 CO2 4.5Kg Squeeze grip


Providing 4.5Kg CO2 Gas Type Fire Extinugisher, Trolley Mounted,
Easy Weight Management used Unused Mechanism, Squeeze Grip,
Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM
Diameter 140MM, Discharge Time less than13 Secs, Controllable
discharge mechanism, Applicable on Class B&C Fire, B Rating 13B,
Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & each 16303.00
Machining, Internal Coating of Can : Not Applicable, External coating
of Can : Spray Painting, Sheet metal thickness : 4.5MM ISI Approved,
1 Year Warranty. with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.35 Providing 4.5Kg CO2 Wheel Type


Providing 4.5Kg CO2 gas valve type Fire Extinugisher, Trolley
Mounted, Easy Weight Management used Unused Mechanism,
Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM
Diameter 140MM, Discharge Time less than13 Secs, Controllable
discharge mechanism, Applicable on Class B&C Fire, B Rating 13B,
Can Constuction : Hot spinning/Forging, Valve Construction : Forging each 9723.00
& Machining, Internal Coating of Can : Not Applicable, External coating
of Can : Spray Painting, Sheet metal thickness : 4.5MM ISI Approved,
1 Year Warranty.with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.36 Providing 6.5Kg CO2 Wheel Type


Providing 6.5Kg CO2 Gas valve type Fire Extinugisher, Trolley
Mounted, Easy Weight Management used Unused Mechanism,
Gross Weight 30.5 Kg. empty Weight 24.0 Kg. Can Height 1015MMDiameter
140MM, Discharge Time less than 13 Secs, Controllable
discharge mechanism, Applicable on Class B&C Fire, B Rating 34B,
Can Constuctin : Hot spinning/Forging, Valve Construction : Forging &
Machining, Internal Coating of Can : Not Applicable, External coating each 14732.00
of Can : Spray Painting, Sheet metal thickness : 4.5MM ISI Approved,
1 Year Warranty. with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

Page No. 354

Page 238 of 375


40.37 Providing 22.5Kg CO2 Wheel Type
Providing 22.5Kg CO2 Gas Type Fire Extinugisher, Trolley Mounted,
Easy Weight Management used Unused Mechanism, Gross Weight
93.5 Kg. empty Weight 71.0Kg. Can Height 1333MM Diameter
232MM, Discharge Time less than20 Secs, Controllable discharge
mechanism, Applicable on Class B&C Fire, Can Constuction: each 41250.00
Hot spinning/Forging, Valve Construction : Forging & Machining,
Internal Coating of Can : Not Applicable, External coating of Can
: Spray Painting, Sheet metal thickness : 5.20 MM ISI Approved,
1 Year Warranty. complete

40.38 Providing CO2 Aluminium - 2kg


Providing 2Kg CO2 Gas aluminium body Squeeze grip Fire Extinugisher,
Used Unused Mechanism, Squeeze Grip, Gross Weight 5.16 Kg. empty
Weight 3.16Kg. Can Height 615MM Diameter 111MM, Discharge Time
less than 8 Secs, Controllable discharge mechanism, Applicable on
Class B&C Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion,
Valve Construction : Forging & Machining, Internal Coating of Can : Not
Applicable, External coating of Can : Spray Painting, Aluminium metal each 9723.00
ISO & PESO Approved, 3 Year Warranty. complete

40.39 Providing CO2 Aluminium - 4.5kg


Providing 4.5Kg CO2 Gas Type aluminium body Squeeze grip Fire
Extinugisher, Trolley Mounted, Easy Weight Management, Used Unused
Mechanism, Squeeze Grip, Gross Weight 11.16Kg. empty Weight
6.66Kg. Can Height 860MM Diameter 140MM, Discharge Time less
than10 Secs, Controllable discharge mechanism, Applicable on Class
B&C Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion, each 14143.00
Valve Construction : Forging & Machining, Internal Coating of Can : Not
Applicable, External coating of Can : Spray Painting, Aluminium metal
ISO & PESO Approved, 3 Year Warranty. complete

40.40 Providing Aqueous Film-Forming Foam - 9 Ltr


Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type,
Stored Pressure Type, Pressure Gauge, Gross Weight 15.10kg. empty
weight 6.10kg Can Height 615MM, Diameter 175 MM, Discharge Time
less than 60 Secs, Controllable discharge mechanism (Squeeze grip
with easy snap safety seal), Range minimum 6 Meters, applicable on
Class A,B,C A Rating 13A, B Rating 55B, Can Construction; Deep
drawn & CO, Mig welded, Valve Construction: Forging & Machining,
Internal Coating of Can : Epoxy Powder coating, External Coating of Can : each 7267.00
Epoxy Polyster Powder coating, Sheet metal thickness: 2.0MM, ISI and EN
Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 355


40.41 Providing Aqueous Film-Forming Foam - 50 Ltr
Providing 50 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type,
External Cartridge Type, Pressure Gauge, Gross Weight 102kg. empty
weight 52kg Can Height 1192MM, Diameter 300 MM, Discharge Time
less than 180 Secs, Controllable discharge mechanism (Squeeze grip
with easy snap safety seal), Range minimum 10 Meters, applicable on
Class A,B,Can Construction; Deep drawn & CO2, Mig welded, Valve each 26518.00
Construction: Forging & Machining, Internal Coating of Can : Epoxy
Powder coating, External Coating of Can : Epoxy Polyster Powder
coating, Sheet metal thickness: 4.0MM, 1 Years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

Page 239 of 375


40.42 Providing Water - 9 Ltr - Stored Pressure
Providing 9 Ltr Water type Fire Extinugisher, Stored Pressure Type,
Pressur Gauge, Gross Weight 15.1kg. empty weight 6.1kg Can Height
615MM, Diameter 175 MM, Discharge Time less than 120 Secs,
Controllable discharge mechanism (Squeeze grip with easy snap safety
seal), Range minimum 6 Meters, applicable on Class A Fire, A Rating 3A,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction:
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal each 6874.00
thickness: 2.0MM, ISI and EN Approved, Helium Leak Detection Tested,
1 Years Warranty with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.43 Providing Water - 50 Ltr


Providing 50 Ltr Fire Extinugisher Water Type, External Cartidge,
Pressure Gauge, Gross Weight 108kg. empty weight 58kg Can Height
1200MM, Diameter 300 MM, Discharge Time less than 180 Secs,
Controllable discharge mechanism (Squeeze grip with easy snap
safety seal), Range minimum 10 Meters, applicable on Class A Fire,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction:
Forging & Machining, Internal Coating of Can : Epoxy Powder coating, each 23571.00
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 4.0MM, 1 Years Warranty with instalert system with Superior
quality EPDM Rubber Hosepipe etc., complete

40.44 Providing Hydro Pyroquell Sytem - 2ltr


Providing 2 Ltr Hydro Pyroquell Sytem Watermist technology base,
Stored pressure type, Rating -15F, Solid stainless body to withstand
hight temperatures, Tamper-proof safety seal, Effective on Class-A,
Class-B, Class-F and Electrically Started Fires, Built-in pressure
gauge, Instalert, Uses distilled water, Gross Weight 4.60 Kg, empty
Weight 2.60kg, can Height 440mm Diameter 140MM, Controllable
discharge mechanism (Squeeze grip with easy snap safety seal), Can each 21017.00
Construction : Deep drawn & CO2 Mig welded, Valve Construction
: Forgin & Machining, ERDA approved, Sheet metal thickness : 1.50MM,
Helium Leak Detection Tested, Discharge Time : Min. 8 Sec.,
5 Year Warranty complete

Page No. 356


40.45 Providing Hydro Pyroquell Sytem - 3ltr
Providing 3 Ltr Hydro Pyroquell Sytem Watermist technology base,
Stored pressure type, Rating -5A. 21B & 25F, Solid stainless body
to withstand hight temperatures, Tamper-proof safety seal, Effective
on Class-A, Class-B, Class-F and Electrically Started Fires, Built-in
pressure gauge, Instalert, Uses distilled water, Gross Weight 6.23 Kg,
empty Weight 3.23kg, can Height 480mm Diameter 160MM, Controllable
discharge mechanism (Squeeze grip with easy snap safety seal), Can each 25142.00
Construction : Deep drawn & CO2 Mig welded, Valve Construction
: Forgin & Machining, ERDA approved, Sheet metal thickness :
1.50MM, Helium Leak Detection Tested, Discharge Time : Min. 13 Sec.,
5 Year Warranty complete

40.46 Providing Hydro Pyroquell Sytem - 6ltr


Providing 6 Ltr Hydro Pyroquell Sytem Watermist technology base,
Stored pressure type, Rating -8A. 34B & 40F, Solid stainless body
to withstand hight temperatures, Tamper-proof safety seal, Effective
on Class-A, Class-B, Class-F and Electrically Started Fires, Built-in
pressure gauge, Instalert, Uses distilled water, Gross Weight 10.4 Kg,
empty Weight 4.4kg, can Height 615mm Diameter 175MM, Controllable
discharge mechanism (Squeeze grip with easy snap safety seal), Can each 33687.00
Construction : Deep drawn & CO2 Mig welded, Valve Construction
: Forgin & Machining, ERDA approved, Sheet metal thickness :
1.50MM, Helium Leak Detection Tested, Discharge Time : Min. 13 Sec.,
5 Year Warranty complete

Page 240 of 375


40.47 Providing Green mist - 2ltr
Green mist Extinguishers : Providing 2 Ltr Watermist technology base,
Stored pressure type, Rating -15F, Mild steel body, Tamper-proof safety
seal, Effective on Class-A, Class-B, Class-F and Electrically Started
Fires, Built-in pressure gauge, Instalert, Uses distilled water, Gross
Weight 4.55 Kg, empty Weight 2.73kg, can Height 435mm Diameter
140MM, Controllable discharge mechanism (Squeeze grip with easy
snap safety seal), Can Construction : Deep drawn & CO2 Mig welded,
Valve Construction : Forgin & Machining, ERDA approved, Sheet metal each 14731.00
thickness : 1.60MM, Helium Leak Detection Tested, Discharge Time :
Min. 22 Sec., 5 Year Warranty with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete

Page No. 357


40.48 Providing Green mist - 3ltr
Green mist Extinguishers : Providing 3 Ltr Watermist technology base,
Stored pressure type, Rating -5A. 21B & 25F, Mild Steel body, Tamperproof
safety seal, Effective on Class-A, Class-B, Class-F and Electrically
Started Fires, Built-in pressure gauge, Instalert, Uses distilled water,
Gross Weight 6.23 Kg, empty Weight 3.23kg, can Height 480mm
Diameter 160MM, Controllable discharge mechanism (Squeeze grip
with easy snap safety seal), Can Construction : Deep drawn & CO2 Mig each 13259.00
welded, Valve Construction : Forgin & Machining, ERDA approved,
Sheet metal thickness : 1.60MM, Helium Leak Detection Tested,
Discharge Time : Min. 13Sec., 5 Year Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.49 Providing Green mist - 6ltr


Green mist Extinguishers : Providing 6 Ltr Watermist technology base,
Stored pressure type, Rating -8A. 34B & 40F, Mild steel body t,
Tamperproof
safety seal, Effective on Class-A, Class-B, Class-F and Electrically
Started Fires, Built-in pressure gauge, Instalert, Uses distilled water,
Gross Weight 12.15 Kg, empty Weight 6.15kg, can Height 615mm
Diameter 175MM, Controllable discharge mechanism (Squeeze grip each 25142.00
with easy snap safety seal), Can Construction : Deep drawn & CO2
Mig welded, Valve Construction : Forgin & Machining, ERDA approved,
Sheet metal thickness : 2.00MM, Helium Leak Detection Tested,
Discharge Time : Min. 64 Sec., 5 Year Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.50 Providing CQRS 2 Kg - Direct Low Pressue System


Providing CQRS 2 Kg - Direct Low Pressue System - Gross Weight
3.98 Kg, Empty Weight 1.98 Kg, Can Height 333 MM, Diameter
108MM, Can construction : Deep Drawn, Valve Construction : Forging /
Machining, External Construction : Epoxy Powder Coating, Helium Leak
Detection Tested, Sheet Metal Thickness: 1.60MM, 1 Year warranty,
Valve, Nickel Plated, With Intergrated Ball Valve, Integrated position
control for ball valve: open - close, Extinguishing Clean Agent FE 36,
Zero ODP, Stored Pressue, Fitted with Pressue Gauge, Control Panel
having Monitoring LED’s for AC Power, System On, Discharged, Valve
Closed, Valve Open, Pressure Healthy, Strobe Red, Strobe Amber,
OLED Graphic Display 95x16, Battery Backp, 3 Outputs using Potential
Free relay contact, Audio Output using Piezo buzzer, 3 Meter Sensor Tue each 97232.00
UV Resistance with Pressrization of Tube Using Nitrogen Gas, End of
Line Plug 1 Pc, End of Line Adapter 1 Pc, T Connection/Elbow/Straight
Connection 1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc,
Tube Attchment 6 Pc. complete

Page 241 of 375


40.51 Providing CQRS 4 Kg - Direct Low Pressue System
Providing CQRS 4 Kg - Direct Low Pressue System - Gross Weight
7 Kg, Empty Weight 3 Kg, Can Height 413 MM, Diameter 140MM, Can
construction : Deep Drawn, Valve Construction : Forging / Machining,
External Construction : Epoxy Powder Coating, Helium Leak Detection
Tested, Sheet Metal Thickness: 1.60MM, 1 Year warranty, Valve, Nickel
Plated, With Intergrated Ball Valve, Integrated position control for ball
valve: open - close, Extinguishing Clean Agent FE 36, Zero ODP, Stored
Pressue, Fitted with Pressue Gauge, Control Panel having Monitoring
LED’s for AC Power, System On, Discharged, Valve Closed, Valve Open,
Pressure Healthy, Strobe Red, Strobe Amber, OLED Graphic Display
95x16, Battery Backp, 3 Outputs using Potential Free relay contact,
Audio Output using Piezo buzzer, 4 Meter Sensor Tue UV Resistance each 117857.00
with Pressrization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc, End
of Line Adapter 1 Pc, T Connection/Elbow/Straight Connection
1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
8Pc. complete

Page No. 358


40.52 Providing CQRS 6 Kg - Direct Low Pressue System
Providing CQRS 6 Kg - Direct Low Pressue System - Gross Weight
9.42 Kg, Empty Weight 3.42 Kg, Can Height 460 MM, Diameter
160MM, Can construction : Deep Drawn, Valve Construction : Forging /
Machining, External Construction : Epoxy Powder Coating, Helium Leak
Detection Tested, Sheet Metal Thickness: 2.00MM, 1 Year warranty,
Valve, Nickel Plated, With Intergrated Ball Valve, Integrated position
control for ball valve: open - close, Extinguishing Clean Agent FE 36,
Zero ODP, Stored Pressue, Fitted with Pressue Gauge, Control Panel
having Monitoring LED’s for AC Power, System On, Discharged, Valve
Closed, Valve Open, Pressure Healthy, Strobe Red, Strobe Amber,
OLED Graphic Display 95x16, Battery Backp, 3 Outputs using Potential
Free relay contact, Audio Output using Piezo buzzer, 5 Meter Sensor Tue each 135536.00
UV Resistance with Pressrization of Tube Using Nitrogen Gas, End of
Line Plug 1 Pc, End of Line Adapter 1 Pc, T Connection/Elbow/Straight
Connection 1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc,
Tube Attchment 10Pc. complete

40.53 Providing CQRS 9 Kg - Direct Low Pressue System


Providing CQRS 9 Kg - Direct Low Pressue System - Gross Weight
14.53 Kg, Empty Wight 5.53Kg, Can Height 590 MM, Diameter
175MM, Can construction : Deep Drawn, Valve Construction : Forging /
Machining, External Construction : Epoxy Powder Coating, Helium Leak
Detection Tested, Sheet Metal Thickness: 2.00MM, 1 Year warranty,
Valve, Nickel Plated, With Intergrated Ball Valve, Integrated position
control for ball valve: open - close, Extinguishing Clean Agent FE 36,
Zero ODP, Stored Pressue, Fitted with Pressue Gauge, Control Panel
having Monitoring LED’s for AC Power, System On, Discharged, Valve
Closed, Valve Open, Pressure Healthy, Strobe Red, Strobe Amber,
OLED Graphic Display 95x16, Battery Backp, 3 Outputs using Potential
Free relay contact, Audio Output using Piezo buzzer, 6 Meter Sensor Tue each 153214.00
UV Resistance with Pressrization of Tube Using Nitrogen Gas, End of
Line Plug 1 Pc, End of Line Adapter 1 Pc, T Connection/Elbow/Straight
Connection 1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc,
Tube Attchment 10Pc. complete

Page No. 359

Page 242 of 375


40.54 Providing CQRS 2 Kg - Direct high Pressue System
Providing CQRS 2 Kg - Direct high Pressue System - Gross Weight
8.52 Kg, Empty Weight 6.52 Kg, Can Height 595 MM, Diameter 108MM,
Can construction : Hot Spinning/Heat Treatment, Valve Construction :
Forging / Machining, External Construction : Epoxy Powder Coating,
Sheet Metal Thickness: 3.5MM, 1 Year warranty, Valve, Brass, Cylinder
thread : M10x1, Outlet thread: W21, 8x1/14”, Bursting Disc: 250 bar,
Integrated position control for Valve: activated - not activated, Intergrated
position control for ball valve: open-close, Extinguishing Agent CO2
Control Panel having Monitoring LED’s for AC Power, System on,
Discharged, Valve Closed, Valve Open, Pressure Healthy, Strobe Red,
Strobe Amber, OLED Graphic Display 95x16, Battery Backp, 3 Outputs
using Potential Free relay contact, Audio Output using Piezo buzzer, each 88393.00
3 Meter Sensor Tube UV Resistance with Pressurization of Tube
Using Nitrogen Gas, End of Line Plug 1 Pc, End of Line Adapter 1 Pc,
T Connection/Elbow/Straight Connection 1 Pc, Pressure Switch M 10x1,
Switchpoint 15 bar - 1 Pc, Tube Attchment, 6 Pc. complete

40.55 Providing CQRS 4.5 Kg - Direct high Pressue System


Providing CQRS 4.5Kg - Direct High Pressue System - Gross Weight
14.73 Kg, Empty Weight 13.23 Kg, Can Height 735 MM, Diameter
139MM, Can construction : Hot Spinning/Heat Treatment, Valve
Construction : Forging / Machining, External Construction : Epoxy
Powder Coating, Sheet Metal Thickness: 4.2MM, 1 Year warranty, Valve,
Brass, Cylinder thread : 25E, Dip tube thread M10x1, Outlet thread:
W21, 8x1/14”, Bursting Disc: 250 bar, Integrated position control for
Valve: activated - not activated, Intergrated position control for ball valve:
open-close, Extinguishing Agent CO2 Control Panel having Monitoring
LED’s for AC Power, System on, Discharged, Valve Closed, Valve Open,
Pressure Healthy, Strobe Red, Strobe Amber, OLED Graphic Display
95x16, Battery Backp, 3 Outputs using Potential Free relay contact, each 106071.00
Audio Output using Piezo buzzer, 3 Meter Sensor Tube UV Resistance
with Pressurization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc,
End of Line Adapter 1 Pc, T Connection/Elbow/Straight Connection
1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
8 Pc. complete

40.56 Providing CQRS 6.5Kg - Direct High Pressue System


Providing CQRS 6.5Kg - Direct High Pressue System - Gross Weight
23.2 Kg, Empty Weight 16.7 Kg, Can Height 980 MM, Diameter
139.7MM, Can construction : Hot Spinning/Heat Treatment, Valve
Construction : Forging / Machining, External Construction : Epoxy
Powder Coating, Sheet Metal Thickness: 4.5MM, 1 Year warranty, Valve,
Brass, Cylinder thread : 25E, Dip tube thread M10x1, Outlet thread:
W21, 8x1/14”, Bursting Disc: 250 bar, Integrated position control for
Valve: activated - not activated, Intergrated position control for ball valve:
open-close, Extinguishing Agent CO2 Control Panel having Monitoring
LED’s for AC Power, System on, Discharged, Valve Closed, Valve Open,
Pressure Healthy, Strobe Red, Strobe Amber, OLED Graphic Display
95x16, Battery Backp, 3 Outputs using Potential Free relay contact, each 120804.00
Audio Output using Piezo buzzer, 3 Meter Sensor Tube UV Resistance
with Pressurization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc,
End of Line Adapter 1 Pc, T Connection/Elbow/Straight Connection
1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
10 Pc. complete

Page No. 360

Page 243 of 375


40.57 Providing CQRS 22.5Kg - Direct High Pressue System
Providing CQRS 22.5Kg - Direct High Pressue System - Gross Weight
63.6 Kg, Empty Weight 41.1 Kg, Can Height 1170 MM, Diameter 232MM,
Can construction : Hot Spinning/Heat Treatment, Valve Construction :
Forging / Machining, External Construction : Epoxy Powder Coating,
Sheet Metal Thickness: 4.5MM, 1 Year warranty, Valve, Brass, Cylinder
thread : 25E, Dip tube thread M10x1, Outlet thread: W21, 8x1/14”,
Bursting Disc: 250 bar, Integrated position control for Valve: activated
- not activated, Intergrated position control for ball valve: open-close,
Extinguishing Agent CO2 Control Panel having Monitoring LED’s for AC
Power, System on, Discharged, Valve Closed, Valve Open, Pressure
Healthy, Strobe Red, Strobe Amber, OLED Graphic Display 95x16, each 153214.00
Battery Backp, 3 Outputs using Potential Free relay contact, Audio
Output using Piezo buzzer, 3 Meter Sensor Tube UV Resistance with
Pressurization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc, End
of Line Adapter 1 Pc, T Connection/Elbow/Straight Connection 1 Pc,
Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
12 Pc. complete

40.58 Smoke Detection - Wireless


Providing Smoke Detection Control Panel - 28 Wireless Zone,
2 Hardwired Zone, Tamper Altert, passcode protected, RF Jamming
recongnition, diagnition, diagnostic feture for RF signal strength between
panel and each detector, event reporting using PSTN Telephone line,
dialing upto 4 telephone numbers, event reporting as per users choice,
remote control using telephone line, LCD Screen Display, Intuitive each 37420.00
graphic and audible user interphase, Two Way voice interaction, Battery
Backup stand by time upto 12 hrs. complete

40.59 Smoke Detector


Smoke Detector - Fully Supervised Smoke Detector, Photoelectric
detection technology for superior detection sensitivity, sound and
transmitted alrerts for smoke, tamper and low battery, works on each 3832.00
powercode protocol, easy programming and enrolling to the control
panel, Long life 9 votl alkaline or lithium battery simple ceiling mount
installation with separate installation bracket. complete

Page No. 361


40.60 Wireless Repeater
Repeater : The Wireless repeater extends the communication range
of Detectors, by relaying data between receiver and remote wireless each 9723.00
transmitters, Up to 16 auxiliary repeaters can be positioned between
the farthest group of receivers transmitters and the receiver. complete
40.61 Wireless Siren Strobe
External Wireless Siren - a fuly supervised Power Code “outdoor
(IP55) wireless siren and strobe light, Designed for external installation,
Wirefree connection between control panel and siren, Convenient and
rapid no-mess installation, Separate fire alarm signals, 98 db Piezo
siren and high power strobe light, Weather-resistant IP55, Two-way
communication for local & remote diagnostic, Plug-in powr supply, NIMH
rechargeable back up battery, Transmits status, tamper, low battery, each 12964.00
supervisior and AC loss messages to the control panel, Tri-state tamper
switch identifies screw mainpulation removal of cover or prying from
the wall complete

40.62 Smoke Detector Model


Dual chamber ionization detectors provide a high degree of sensitivity
and reliability, A unique inter-connectivity feature can be used to warn
occupants in adjoining areas, An independent 9 volt power supply and a
low battery warning system ensure that the smoke detectors are always
in working condition, Type - Dual Chamber lonisation, Connectivity - each 3832.00
Wired, Alarm Sound Level - 85dB complete

Page 244 of 375


40.63 External GSM Dialler
Providing the GSM unit enables the system to operate over cellular
net work. Indoor plug-in transformer, 120VAC 60 Hz / 9 VAC Current each 22098.00
Consumption : 40mA approx (idle), < 400mA (transmission), Backup
Battery: Ni-Metal, 7.2V, 1300 mAh complete
40.64 Smoke Detector Model
Proividing Dual Technology Smoke Detectors, Sensor Ionisation and
photo electric, Button for Test/Silence, Remote Control silence/Test uses
mot remote controls to temporarily quiet unwanted alarms and test alarm
function, Intelligent Sensing Technology TM helps reduce the number each 4035.00
of nuisance alarms, 9V Battery complete

Page No:362
40.65 Smoke Detector
Providing Dual Chamber lonisation type Smoke Detectors with Escape
Light, 9V Battery Operated, Test Button complete each 3041.00

40.66 Escape Singage


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
removing the light source (in minutes) : 60 minutes, Luminescent
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm. sqcm 1.00
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay*
(In Minutes) :3100

40.67 Singages for Walls/Floors


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
removing the light source (in minutes) : 60 minutes, Luminescent
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm. sqcm 2.00
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay*
(In Minutes) :3100

40.68 Panaromic Signage


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
removing the light source (in minutes) : 60 minutes, Luminescent intensity
sqcm 1.00
(milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) :3100

40.69 Evacution Plan (Price for 10 + unit)


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
removing the light source (in minutes) : 60 minutes, Luminescent
sqcm 6.00
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) :3100

Page No. 363

Page 245 of 375


40.70 Evacution Plan (Price for less than 10 unit)
Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
removing the light source (in minutes) : 60 minutes, Luminescent
sqcm 7.50
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) :3100

40.71 Marking Strips


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
removing the light source (in minutes) : 60 minutes, Luminescent
sqcm 1.90
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) : 3100

40.72 Escape Gear


Providing’s Escape Gear, Mild Steel Box size 425mm x 360 mm
140mm, Epoxy power coated to protect it from weathering, Smoke
Hood: Tested to European Standard EN 403 : 1993-S, Known to reduce
Carbon monoxide,propenal (acrolein), hydrogen choloride, hydrogen
cyanide and solid & liquid toxic particles to manageable level for at least 15
each 15911.00
minutes, shall withstand temperatures upto 80 Deg. Single Use only,Fire
Blanket : Size : 1.2m x 1.8m, Used to cover any vessel containing the fire
completely, Used to extinuish a clothing fire wrap blanket around victim

40.73 Supplying, Installing testing & commissioning approved make Centrifugal


pump end suction type coupled to Electric motor of suitable HP, fitted on a
commonbase frame and rated for Fireduty. The quated price shall aslo
include 2 Nos. Pressureguages fitted on suction & delivery sides of the Nos. 113041.00
pump. The pumps shall run on 400/440V 3 ph. 50 Hz electric supply. Duty
of pumps: 1620 Lpm @ 70.0m Head. Control panel shall be as specified in
item no, 87

40.74 Supplying, Installing testing & commissioning electrically driven jockey


pump of capacity 180.0 Lmpm at 75.0m head with all the necessary
accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440V AC Nos. 95159.00
supply including foundation bolt etc. complete. Control panel shall be as
per item No.87
Page No. 364

Page 246 of 375


40.75 Supply installing, testing and commissioning COMMON control panel
for fire fighting system consisting of electrical mortor driven 60 HP
Main fire pump, Jockey pump and 12.5 HP consisting of the following
INCOMING: 1 No. Set of phase indicing lamps with SFU Rate 350A
1 No. set of 400 Amps. TPNE Ai.Bus bars 1 No. 0-400 Amps. Ammeter,
1 No.0-600V voltmeter with phase selector switch, Isolating Switch
400 A OUTGOING for Main Electrical Pump: 1 No. 200 Amps MCB
1 No.S/D starter suitable for 60 HP 1 No. Singel phse preventor suitable
for the pump described above 1 No. set of ON/OFF indicating lamps
1 No. Automanual selector switch OUTGOING for Jockey Pump: 1 No.
50 Amps MCB 1 No. DOL starter suitable for 12.50 HP 1 No. Single
phase preventor suitable for the pump described above 1 No. set of
ON/OFF indicating lamps 1 No. Automanual selector switch ENGINE
CONTROL SECTION NO.1 Diesel Engine for Standby pump: a) Main
switch 2 pole ON/OFF -1 No. b) Batter charger with transpormer with
rectifier reistance DC ammeter, DC voltmeter, T/B selector swith -1 set
c) Indicating lamps for fault communication (Battery charger, supply
ON, Control ON, engine running, low oil pressure, high water pressure Unit 187500.00
and enginer overspeed) - 6 Nos. Push buttons for starter, stop reset -
4 Nos. e) Selector switches (Engine control, mode selctor) - 2 Nos. f)
Auxilary rellays/contractors/timer for dsequience operating for starting
and stopping of the engine -1 g) Hooter for audio alarm (Industrial
type) -1 No. Accessoreis for outgoing supply for the morttors GI SWD
earthing wire for the aove motor Accessories for outgoing supply for
Diesel Enginer: Copper conductor armoured cabe 2.5 sqmm of 12 Core
x 2 runs a) Battery 2 strands b) Enginer ON/OFF 2 strands c) Low oil
pressure 3 strands d) Enginer oversped 2 strands e) Water temperature
2 strands f) Spare 1 strand The cost of control panel shall also include
necessary pressure swithces with necessary cabling & inter-locked with
the panel to enable sequential operation of Pumps. Including terrace
mortor necessary earthing All the components shall be housed in a
common cubical. However, the feed cable for diesel engine driven
pump battery charger shall be taken separately

40.76 Supplying Installing testing and commissioning electrically driven


Terrance pump of capacity 900.0 Lpm at 35.0m Head with all the
necessary accessories viz. Pressure guages etc. operating on 3Ph Nos. 79018.00
50Hz, 400/440V AC supply includng foundation, bolts etc. complete.
Control panel shall be as per spesification 87
40.77 Exacavation in all sorts of soil for laying pipes upto 100mm dia including
forming bottom surface to required level, refilling seleted excavated earth
around the pipe in layers of 150mm thick, watering consolidating and cum 219.00
disposing off the surplus earath within the stie or as directed by the site
engineer etc. complete Depth upto 1.0m
Page No. 365
40.78 Supply installation, testing and commissioning of fire alarm Main panel
Nos. 71429.00
with15 zone indication alaram etc. as required
40.79 Supplying Installing testing and commissioning approved make
Centrifugal pump end suction type couple to Electric mortor of suitable HP,
fitted on a common base frame and rated for Fire duty. including 2 nos.
Pressure guages fitted on suction & delivery side of the pump. The pums
shall run on 400/440V, 3ph, 50Hz electric supply, Duty of pumps:2850 Nos. 257143.00
Lpm @ 70.0m Head. Control panel shall be per specification stated in Item
No.87. (Cost of control pannel is not included)

40.80 Supplying, Installing, testing and commisioning of fire hydrant multi stage
pump capable of delivering 2850Lpm @ 70.0m head coupled to water cooled
diesel engine of adequiate HP. It shall be fitted with a radiator on a common
base from with complete ancilalary units such as colling system, non return
Valve, Y strainer, fuel tank of adequate coapcity, Pressue guage, pressure Nos. 491071.00
switch. Control panel shall be per specification stated in Item No.87. (Cost
of control pannel is not included)

40.81 Supplying, Installing, testing and commisioning electrically driven jockey


pump of capacity 180.0 Lpm at 70.0m head with all the necessary
accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440 V AC
supply incldung foudnation, bolts etc. complete Control panel shall be per Nos. 74084.00
specification stated in Item No.87. (Cost of controle pannel is not included)

Page 247 of 375


40.82 Supplying, Installing, testing and commissioning approved make
Centrifugal pump end suction type couple to Electric motor of suitable
Hp, fitted on a common base frame and rated for Fire duty. The quoted
price shall aslso include 2 nos. Pressure guages fitted on suction and
delivery side of the pump. The pumps shall run on 400/440V, 3ph, 35-Hz Nos. 291225.00
electric supply. Duty of pumps: 2850 Lpm @ 90.0m Head. Control panel
shall be per specification stated in Item No.87. (Cost of control pannel is not
included)

40.83 Supplying Installing testing and commissiong COMMON Control panel for
fire fighting system consiting of electrical motor driven 60HP Main fire
pump, Diesel engine driven pump 60 HP Sprinkler pump 50HP & Jockey Nos. 223214.00
pump 25HP
40.84 Supplying, Installing, testing and commissioning approved make
Centrifugal pump end suction type couple to Electric motor of suitable
Hp, fitted on a common base frame and rated for Fire duty. The quoted
price shall aslso include 2 nos. Pressure guages fitted on suction & delivery
side of the pump. The pumps shall run on 400/440V, 3 ph, 50Hz electric Nos. 257143.00
supply. Duty of pums: 1620 Lpm @ 70.0m Head. Control panel shall be per
specification stated in Item No.87. (Cost of control pannel is not included)

Page No. 366


40.85 Supplying, Installing testing and commissioning of fire hydrant multi
stage pump capable of delivering 1620 Lpm @ 70.0m head coupled
to water colled diesel enginer of adequate. HP. It shall be fitted with a
radiator on a common base frame with complete ancillary units such as
colling sytem, non return vialve, Y strainer, fuel tank of adequante capactiy, Nos. 312500.00
Pressure guage, pressure switch etc. complete Control panel shall be per
specification stated in Item No.87. (Cost of control pannel is not included)

40.86 Supplying, Installing testing and commissioning electrically driven jockey


pump of capacity 180.0 Lpm at 70.0m. Head with all the necessary
accessories viz. Pressure guages etc., operating on 3Ph 50Hz,400/440V AC
supply including foundatin, bolts etc. complete, Control panel shall be per Nos. 95159.00
specification stated in Item No.87. (Cost of control pannel is not included)

40.87 FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning


of 63mm mm dia single headed Gun mental Hydrant Valve with flanged
inlet, stop valve, spindle and cast iron hand wheel. It has a female
instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 each 6293.00
Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm 2 of pressure
with blank cap and wheel as per IS 5290 etc. complete Make : WINCO/NEW
Age

40.88 Supplying Installing, testing and commissioning of 63mm mm dia double


headed Gun mental Hydrant Valve with flanged inlet 2Nos, stop valve,
spindle and cast iron hand wheel. It has a 2 Nos female instantaneous
outlet with blank cap and is hydrostatically tested to 21 Kgf/cm2 pressure each 10125.00
having a flow rate of 900 LPM at 7 Kgf/cm2 of pressure confirms to IS :
2190 with blank cap and wheel as per IS 5290 etc. complete

40.89 Supplying Installing, testing and commissioning of Gun metal AIR


each 1875.00
RELEASE VALVE SIZE OF 25mm dia complete
40.90 Supplying Installing, testing and commissioning of Gun metal Branch
pipe size of 63mm dia x19mm dia as per IS 903 Make: WINCO/NEW each 2679.00
AGE complete
40.91 Supplying Installing, testing and commissioning of Reinforced Rubber
Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded
with one set of male and Female Instantainious Gun metal coupling as per each 6291.00
IS 903 WINCO/NEW AGE complete
Page No. 367
40.92 Supplying Installing, testing and commissioning of Hose cabinet
made out of 18 gauge M.S.sheet with double glass door with locing
arrangement and painted with two coats of Fire red Enamel paint at
outer ise of the Box and two coats of white enamel paint at inner side of the each 3839.00
box is to accomodated 2 Nos. of Fire hose box size 20”x24”x10” complete

40.93 Supplying Installing, testing and commissioning of Hose reel cabin


M.S.Pressed reel of 600mm dia swinging type motion which allows a each 4286.00
180° swing and conforms to IS:884/85.

Page 248 of 375


40.94 Supplying Installing, testing and commissioning of 19mm dia 36.50m
length hose with rubber lining smooth bore, reinforced of natural/
synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric
marked with minimum thickness of 1.50mm and to with stand a working each 4643.00
pressure of 10Kgf/sqcm confirms & tested as per IS 444

40.95 Supplying Installing, testing and commissioning of approved make


15mm dia sprinkler bulb pendent/wall mounted type designed to operate
68 degrees centegrad Make Tyco/HD FIRE complete (Colour code of bulb
liquid inside Glass bulb type Pendents As per IS 9972: 57°COrange, 68°C - each 446.00
Red, 79°C - Yellow, 93°C - Green, 141°C - Blue, 182°C- Mauve, 227/260°C
- Black)

40.96.1 Supplying Installing, testing and commissioning of hydraulicallying


operated sprinkler cabit Valve with water meter gong bell and trims as
required, pressure gauges drain Valve, ball Valves check valve, strainer Unit 714.00
etc.-do-100 mm dia. Complete
40.96.2 Supplying Installing, testing and commissioning of hydraulicallying
operated sprinkler cabit Valve with water meter gong bell and trims as
required, pressure gauges drain Valve, ball Valves check valve, strainer Unit 1339.00
etc.-do- 150 mm dia. Complete
40.97.1 Supply, Installation testing and commissioning of approved make heavy
quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 1988.00
includes two coats of metal primer and two coats of Red enamel paint etc. -
do- 200 mm dia. complete

40.97.2 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 1616.00
includes two coats of metal primer and two coats of Red enamel paint etc. -
do- 150 mm dia. complete

40.97.3 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 1230.00
includes two coats of metal primer and two coats of Red enamel paint etc.-
do- 100 mm dia. complete

40.97.4 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 979.00
includes two coats of metal primer and two coats of Red enamel paint etc. -
do- 80 mm dia. complete

40.97.5 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 865.00
includes two coats of metal primer and two coats of Red enamel paint etc.-
do- 65 mm dia. complete

40.97.6 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 763.00
includes two coats of metal primer and two coats of Red enamel paint etc.-
do- 50 mm dia. complete

Page No. 368


40.97.7 Supply, Installation testing and commissioning of approved make heavy
quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 654.00
includes two coats of metal primer and two coats of Red enamel paint etc. -
do- 40 mm dia. complete

40.97.8 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 618.00
includes two coats of metal primer and two coats of Red enamel paint etc. -
do- 32 mm dia. complete

Page 249 of 375


40.97.9 Supply, Installation testing and commissioning of approved make heavy
quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows check
nuts unions, Flanger, Nipples etc. including cutting welding, Trending
fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports work m 571.00
includes two coats of metal primer and two coats of Red enamel paint etc. -
do- 25 mm dia. complete

40.98.1 Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth.-do- 200 mm m 321.00
dia. Complete
40.98.2 Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth. -do- 150 mm m 223.00
dia. Complete
40.98.3 Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth. -do- 100 mm m 179.00
dia. Complete
40.98.4 Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth. -do- 80 mm dia. m 134.00
Complete
40.99.1 Supplying Installation testing and Commissiong of Micro precess base Fire
alram Control panel having power regulation Circuit, which conner to 230
AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with Feather touch
push button switches, Test facility also with work test facility arrangement,
provided in the panel. All this electronic circuits componets are assembled each 16071.00
in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking
arrangements including cost of all mateials etc. -do- Make
Ravel/Golbe/Royale 12 Zone. complete

40.99.2 Supplying Installation testing and Commissiong of Micro precess base Fire
alram Control panel having power regulation Circuit, which conner to 230
AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with Feather touch
push button switches, Test facility also with work test facility arrangement,
provided in the panel. All this electronic circuits componets are assembled each 21429.00
in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking
arrangements including cost of all mateials etc. complete

40.99.3 Supplying Installation testing and Commissiong of Micro precess base Fire
alram Control panel having power regulation Circuit, which conner to 230
AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with Feather touch
push button switches, Test facility also with work test facility arrangement,
provided in the panel. All this electronic circuits componets are assembled each 31250.00
in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking
arrangements including cost of all mateials etc. -do- Make
Ravel/Golbe/Royale 16 Zone. complete

40.99.4 Supplying Installation testing and Commissiong of Micro precess base Fire
alram Control panel having power regulation Circuit, which conner to 230
AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with Feather touch
push button switches, Test facility also with work test facility arrangement,
provided in the panel. All this electronic circuits componets are assembled each 44643.00
in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking
arrangements including cost of all mateials etc. -do- Make
Ravel/Golbe/Royale 20 Zone. complete

40.99.5 Supplying Installation testing and Commissiong of Micro precess base Fire
alram Control panel having power regulation Circuit, which conner to 230
AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with Feather touch
push button switches, Test facility also with work test facility arrangement,
provided in the panel. All this electronic circuits componets are assembled each 93750.00
in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking
arrangements including cost of all mateials etc. -do- Make
Ravel/Golbe/Royale 40 Zone. complete

40.99.6 Supplying Installation testing and Commissiong of Micro precess base Fire
alram Control panel having power regulation Circuit, which conner to 230
AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with Feather touch
push button switches, Test facility also with work test facility arrangement,
provided in the panel. All this electronic circuits componets are assembled each 132143.00
in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking
arrangements including cost of all mateials etc. -do- Make
Ravel/Golbe/Royale 60 Zone. complete

Page 250 of 375


40.99.7 Supplying Installation testing and Commissiong of Micro precess base Fire
alram Control panel having power regulation Circuit, which conner to 230
AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with Feather touch
push button switches, Test facility also with work test facility arrangement,
provided in the panel. All this electronic circuits componets are assembled each 165179.00
in M.S.16 gauge suitable panel cabinet with glass Fraonted and locking
arrangements including cost of all mateials etc. -do- Make
Ravel/Golbe/Royale 76 Zone. complete

40.100 Supplying Installing, testing and commissioning of Smoke/Heat detector


Photo electric type detctor with base LED indicator on Smioke detector fixed
cum rise temperature type heat detector with base Make Applow/System each 3041.00
Sensor complete
40.101 Supplying Installing, testing and commissioning of Manual Call point :It
consists of Micro push button switch with LED and circutary etc.
works on 24V DC LED indicator with glass Fronted, Also with hammer
for breaking the glass incase of Fire. Accomdated in 75x75x30mm size each 1071.00
M.S.16 gauge red enamel painted box Make/Golbe/Ravel/Royale. complete

Page No. 369


40.102 Supplying Installing, testing and commissioning of electronic Hooter,
it conists of electronic circuit to give dual Fire alaram sound with works
24V DC with speaker all encosed in suitable in M.S. 16 gauge red painted each 1607.00
box. Complete
40.103 Supplying Installing, testing and commissioning of Response Indictor
constists of twin LED wioth electronic circutarx work on 24 DC enclose in each 268.00
PVC retangular. Complete
40.104 Supplying and fixing sheet metal box made out of 18 SWG sheet metal with
necessary holes for cable/conduit entry as required with one coat of primer each 86.00
of approved make etc.
40.105 Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade copper with flexible copper conductor confirming
to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed m 29.00
suitable for working voltage upto 1100Volts as per IS-694:1990 &
confirming to GTP of GROUP-B. 2C x 1.5 SqmmV
40.106 SITC of 7AM-12 V Battery for fire alaram system Make EXIDE/AMCo each 1071.00
40.107 Providing and Fixing Fire force board size of 3’x2’ made out to Acrylic
sheet of 3mm thick with letter of different Colums with 8mm thick ply each 2634.00
wood, Alumimum side frame and fixing etc. Complete
40.108 Supplying Installing, testing and commissioning of Public address system
(Two way comminication type) as per requirement of Fire Force authority
and which Generally comprise of Supplying Installing, testing and
commissioning of Approved make 5 W.wall mounted speaker with talk back each 2054.00
facility with store enamel painted M.S.Sheet hosing etc. complete

40.109.1 Supplying Installing, testing and commissioning of P.A.System console


panel with push button with speaker and indictoron Accomdated in each 42857.00
M.S.Cabinet with painting -do- 20 Zone cansole. Complete
40.109.2 Supplying Installing, testing and commissioning of P.A.System console
panel with push button with speaker and indictoron Accomdated in each 84821.00
M.S.Cabinet with painting -do- 40 Zone cansole. Complete
40.109.3 Supplying Installing, testing and commissioning of P.A.System console
panel with push button with speaker and indictoron Accomdated in each 111607.00
M.S.Cabinet with painting -do- 60 Zone cansole. Complete
40.110 P.A.System amplifier 250W RMS out put with complete wiring and
each 28571.00
controls accessable form front Make AHUJA. Complete
40.111 Supplying Installing, testing and commissioning of Ahuja make MIKE
each 1339.00
suitable to I.A.System. Complete
Page No. 370
40.112 Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade flexible copper with low conductor confirming to table 3
class 5 of IS:8130-1984 and (Virgin) PVC insulation and sheathed suitable m 33.00
for working voltage upto 1100Volts as per IS-694:1990 & confirming to GTP
of GROUP-A. 2C x 1.50 Sqmm
40.113 Supplying of four bucket stand alongwith buckets. Complete each 1071.00
40.114 Supplying of two bucket stand alongwith buckets. Complete each 563.00
40.115 Supplying of Hand gloves. Complete pair 152.00
40.116 Supplying of first aid box. Complete each 192.00
40.117 Supplying of SAFETY MASK. Complete each 57.00
40.118 Supplying of FIRST AID CHART with lamination. Complete each 201.00
40.119 Supplying and installation of RUBBER MAT 1mtr x 1mtr -10mm thick.
Nos. 987.00
Complete

Page 251 of 375


40.120.1 Supply, Installation testing and commissioning of approved make heavy
tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 2179.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
200 mm dia. complete

40.120.2 Supply, Installation testing and commissioning of approved make heavy


tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 2106.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes-do- Galvanized Iron
Pipes 150 mm dia. complete two coats of metal primer and two coats of Red
enamel paint etc.-do- Galvanized Iron Pipes 150 mm dia. complete

40.120.3 Supply, Installation testing and commissioning of approved make heavy


tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 1890.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
100 mm dia. complete

40.120.4 Supply, Installation testing and commissioning of approved make heavy


tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 1268.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes 80
mm dia. complete

40.120.5 Supply, Installation testing and commissioning of approved make


heavytubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @
3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore
5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, m 1131.00
Flanger, Nipples etc. including cutting welding, Trending fixing on walls,
ceiling (Using 41-Tech pipe/M.S.angle supports work includes two coats of
metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron
Pipes 65 mm dia. complete

Page 252 of 375


40.120.6 Supply, Installation testing and commissioning of approved make heavy
tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 993.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes 50
mm dia. complete

40.120.7 Supply, Installation testing and commissioning of approved make heavy


tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 878.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes 40
mm dia. complete

40.120.8 Supply, Installation testing and commissioning of approved make heavy


tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 820.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes 32
mm dia. complete

40.120.9 Supply, Installation testing and commissioning of approved make heavy


tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal bore
4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick @ 3.84
Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm Nominal
bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm thick @
7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m, 100mm
Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal bore 5.40mm
thick @ 21.20 Kg/m, Such as Tees elbows check nuts unions, Flanger, m 762.00
Nipples etc. including cutting welding, Trending fixing on walls, ceiling
(Using 41-Tech pipe/M.S.angle supports work includes two coats of metal
primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes 25
mm dia. complete

Page No. 371


Notes :
1 The Recommendations are miniumum for a specific area, incase, the area is
more than specified, high capacity extinguishers may be used based on
these minimum requirements, that is proportionately higher capacity can
be used.
2 In case of dry powder /co2/clean agent types, equivalent lower capacities
may also be used.
3 The halons shall be restricted for essential use only
4 On Implementation of IS 15683, 6 kg and 9 kg dry powder extinguishers
shall be replaced by 5 kg or 10 kg dry powder extinguishers.

Page No. 374

41.0 ENERGY CONSERVATION BUILDING CODE

Page 253 of 375


41.1 External wall insulation with polyurethane foam (PUF) slab
Providing and fixing polyurethane foam (PUF) slab
40mm thick average with PU slab density 36+/-2 kg/m3 for external wall
insulation including necessary polymerized plaster reinforced with glass
fibre mesh, epoxy based bonding adhesive etc., complete with all lead and Sqm 1427.00
lift, transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work.

41.2.1 External wall insulation with polyurethane foam (PUF) spray


Providing and fixing polyurethane foam (PUF) spray
with PU density 35+/-5 kg/m3 for external wall insulation including
necessary adhesive etc., complete with all lead and lift, transportation Sqm 989.00
charges, loading unloading charges, all taxes, cost of all materials, labour,
HOM etc., complete as per direction of engineer incharge of the work. -
Polyurethane foam (PUF) spray 40mm thick

41.2.2 External wall insulation with polyurethane foam (PUF) spray


Providing and fixing polyurethane foam (PUF) spray
with PU density 35+/-5 kg/m3 for external wall insulation including
necessary adhesive etc., complete with all lead and lift, transportation Sqm 1162.00
charges, loading unloading charges, all taxes, cost of all materials, labour,
HOM etc., complete as per direction of engineer incharge of the work. -
Polyurethane foam (PUF) spray 50mm thick

41.33.1 External wall insulation with extruded polystyrene (XPS) thermal


insulating boards
Providing and fixing EXTRUDED POLYSTYRENE (XPS) thermal
insulating boards for external wall insulation including necessary fasteners
etc., complete with all lead and lift, transportation charges, loading Sqm 449.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per the direction of engineer incharge of the work.-Extruded Polystyrene
(XPS) thermal insulating boards 25mm thick

41.3.2 External wall insulation with extruded polystyrene (XPS) thermal


insulating boards
Providing and fixing EXTRUDED POLYSTYRENE (XPS) thermal
insulating boards for external wall insulation including necessary fasteners
etc., complete with all lead and lift, transportation charges, loading Sqm 738.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per the direction of engineer incharge of the work.-Extruded Polystyrene
(XPS) thermal insulating boards 50mm thick

41.3.3 External wall insulation with extruded polystyrene (XPS) thermal


insulating boards
Providing and fixing EXTRUDED POLYSTYRENE (XPS) thermal
insulating boards for external wall insulation including necessary fasteners
etc., complete with all lead and lift, transportation charges, loading Sqm 1027.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per the direction of engineer incharge of the work.-Extruded Polystyrene
(XPS) thermal insulating boards 75mm thick

41.3.4 External wall insulation with extruded polystyrene (XPS) thermal


insulating boards
Providing and fixing EXTRUDED POLYSTYRENE (XPS) thermal
insulating boards for external wall insulation including necessary fasteners
etc., complete with all lead and lift, transportation charges, loading Sqm 1317.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per the direction of engineer incharge of the work.-Extruded Polystyrene
(XPS) thermal insulating boards 100mm thick

41.4.1 Cavity wall insulation with polyurethane foam (PUF)spray


Providing and fixing
polyurethane foam (PUF) spray with PU density 35+/-5 kg/m3 density for
insulation of cavity wall including necessary fasteners etc., complete with Sqm 886.00
all lead and lift, transportation charges, loading unloading charges, all
taxes, cost of all materials, labour, HOM etc., complete as per direction of
engineer incharge of the work. -Polyurethane foam (PUF) spray with PU
foam 40mm thick
41.4.2 Cavity wall insulation with polyurethane foam (PUF)spray
Providing and fixing
polyurethane foam (PUF) spray with PU density 35+/-5 kg/m3 density for
insulation of cavity wall including necessary fasteners etc., complete with Sqm 1166.00
all lead and lift, transportation charges, loading unloading charges, all
taxes, cost of all materials, labour, HOM etc., complete as per direction of
engineer incharge of the work. -Polyurethane foam (PUF) spray with PU
foam 50mm thick

Page 254 of 375


Page No:376
41.5.1 Cavity wall insulation with Glass wool slab
Providing and fixing glass wool slab-
resin bonded with density 48 kg/m3 for insulation of cavity wall, fixed
using GI wire 200 SWG, GI chicken mesh 12.50mmx24 SWG including
necessary criss-cross GI wire mesh, raw plugs, adhesive etc., complete with Sqm 451.00
all lead and lift, transportation charges, loading unloading charges, all
taxes, cost of all materials, labour, HOM etc., complete as per direction of
engineer incharge of the work. -Glass wool slab 12mm thick resin bonded
slab

41.5.2 Cavity wall insulation with Glass wool slab


Providing and fixing glass wool slab-
resin bonded with density 48 kg/m3 for insulation of cavity wall, fixed
using GI wire 200 SWG, GI chicken mesh 12.50mmx24 SWG including
necessary criss-cross GI wire mesh, raw plugs, adhesive etc., complete with Sqm 616.00
all lead and lift, transportation charges, loading unloading charges, all
taxes, cost of all materials, labour, HOM etc., complete as per direction of
engineer incharge of the work. -Glass wool slab 25mm thick resin bonded
slab

41.5.3 Cavity wall insulation with Glass wool slab


Providing and fixing glass wool slab-
resin bonded with density 48 kg/m3 for insulation of cavity wall, fixed
using GI wire 200 SWG, GI chicken mesh 12.50mmx24 SWG including
necessary criss-cross GI wire mesh, raw plugs, adhesive etc., complete with Sqm 745.00
all lead and lift, transportation charges, loading unloading charges, all
taxes, cost of all materials, labour, HOM etc., complete as per direction of
engineer incharge of the work. -Glass wool slab 50mm thick resin bonded
slab

41.6.1 Cavity wall insulation with rock wool slab


Providing and fixing rock wool slab-
resin bonded rock wool having density 36+/-5 kg/m3 for insulation of
cavity wall with including necessary criss-cross GI wire mesh, raw plugs,
adhesive etc., complete with all lead and lift, transportation charges, Sqm 375.00
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Rock wool slab
25mm thick resin bonded rock wool slab

41.6.2 Cavity wall insulation with rock wool slab


Providing and fixing rock wool slab-
resin bonded rock wool having density 36+/-5 kg/m3 for insulation of
cavity wall with including necessary criss-cross GI wire mesh, raw plugs,
adhesive etc., complete with all lead and lift, transportation charges, Sqm 420.00
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Rock wool slab
40mm thick resin bonded rock wool slab

41.6.3 Cavity wall insulation with rock wool slab


Providing and fixing rock wool slab-
resin bonded rock wool having density 36+/-5 kg/m3 for insulation of
cavity wall with including necessary criss-cross GI wire mesh, raw plugs,
adhesive etc., complete with all lead and lift, transportation charges, Sqm 435.00
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Rock wool slab
50mm thick resin bonded rock wool slab

41.6.4 Cavity wall insulation with rock wool slab


Providing and fixing rock wool slab-
resin bonded rock wool having density 36+/-5 kg/m3 for insulation of
cavity wall with including necessary criss-cross GI wire mesh, raw plugs,
adhesive etc., complete with all lead and lift, transportation charges, Sqm 475.00
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Rock wool slab
65mm thick resin bonded rock wool slab

41.6.5 Cavity wall insulation with rock wool slab


Providing and fixing rock wool slab-
resin bonded rock wool having density 36+/-5 kg/m3 for insulation of
cavity wall with including necessary criss-cross GI wire mesh, raw plugs,
adhesive etc., complete with all lead and lift, transportation charges, Sqm 510.00
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Rock wool slab
75mm thick resin bonded rock wool slab

Page 255 of 375


41.6.6 Cavity wall insulation with rock wool slab
Providing and fixing rock wool slab-
resin bonded rock wool having density 36+/-5 kg/m3 for insulation of
cavity wall with including necessary criss-cross GI wire mesh, raw plugs,
adhesive etc., complete with all lead and lift, transportation charges, Sqm 710.00
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Rock wool slab
100mm thick resin bonded rock wool slab

41.7.1 Cavity wall insulation with Extruded Polystyrene (XPS)


Providing and fixing
extruded polystyrene (XPS) thermal insulating boards having density 36+/-
5 kg/m3 for insulation of cavity wall with including necessary criss-cross
GI wire mesh, raw plugs, adhesive etc., complete with all lead and lift, Sqm 1056.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -Extruded Polystyrene (XPS) 50mm thick thermal
insulating boards
41.7.2 Cavity wall insulation with Extruded Polystyrene (XPS)
Providing and fixing
extruded polystyrene (XPS) thermal insulating boards having density 36+/-
5 kg/m3 for insulation of cavity wall with including necessary criss-cross
GI wire mesh, raw plugs, adhesive etc., complete with all lead and lift, Sqm 1236.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -Extruded Polystyrene (XPS) 60mm thick thermal
insulating boards
41.7.3 Cavity wall insulation with Extruded Polystyrene (XPS)
Providing and fixing
extruded polystyrene (XPS) thermal insulating boards having density 36+/-
5 kg/m3 for insulation of cavity wall with including necessary criss-cross
GI wire mesh, raw plugs, adhesive etc., complete with all lead and lift, Sqm 1273.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -Extruded Polystyrene (XPS) 70mm thick thermal
insulating boards
41.7.4 Cavity wall insulation with Extruded Polystyrene (XPS)
Providing and fixing
extruded polystyrene (XPS) 25mm thick thermal insulating boards having
density 32 kg/m3 for insulation of cavity wall with including necessary Sqm 617.00
criss-cross GI wire mesh, raw plugs, adhesive etc., complete with all lead
and lift, transportation charges, loading unloading charges, all taxes, cost
of all materials, labour, HOM etc., complete as per direction of engineer
incharge of the work.
Page No:377
41.7.5 Cavity wall insulation with Extruded Polystyrene (XPS)
Providing and fixing
extruded polystyrene (XPS) 50mm thick thermal insulating boards having
density 32 kg/m3 for insulation of cavity wall with including necessary Sqm 927.00
criss-cross GI wire mesh, raw plugs, adhesive etc., complete with all lead
and lift, transportation charges, loading unloading charges, all taxes, cost
of all materials, labour, HOM etc., complete as per direction of engineer
incharge of the work.
41.7.6 Cavity wall insulation with Extruded Polystyrene (XPS)
Providing and fixing
extruded polystyrene (XPS) 75mm thick thermal insulating boards having
density 32 kg/m3 for insulation of cavity wall with including necessary Sqm 1237.00
criss-cross GI wire mesh, raw plugs, adhesive etc., complete with all lead
and lift, transportation charges, loading unloading charges, all taxes, cost
of all materials, labour, HOM etc., complete as per direction of engineer
incharge of the work.
41.7.7 Cavity wall insulation with Extruded Polystyrene (XPS)
Providing and fixing
extruded polystyrene (XPS) 100mm thick thermal insulating boards having
density 32 kg/m3 for insulation of cavity wall with including necessary Sqm 1547.00
criss-cross GI wire mesh, raw plugs, adhesive etc., complete with all lead
and lift, transportation charges, loading unloading charges, all taxes, cost
of all materials, labour, HOM etc., complete as per direction of engineer
incharge of the work.

Page 256 of 375


41.8.1 Over deck insulation with Polyurethane foam (PUF) slab
Providing and fixing polyurethane foam (PUF) slab with PU slab density
36+/-2 kg/m3 insulation for over deck covered with two layers of 40mm
thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) using
12.50mm nominal size aggregates nd top layer of 10mm thick plaster with
cement mortar 1:3 finished with floating coat of neat cement, including
necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, Sqm 1460.00
epoxy bases bonding adhesive etc., complete with all lead and lift,
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -Polyurethane foam (PUF) slab 40mm thick

41.8.2 Over deck insulation with Polyurethane foam (PUF) slab


Providing and fixing polyurethane foam (PUF) slab with PU slab density
36+/-2 kg/m3 insulation for over deck covered with two layers of 40mm
thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) using
12.50mm nominal size aggregates nd top layer of 10mm thick plaster with
cement mortar 1:3 finished with floating coat of neat cement, including
necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, Sqm 1815.00
epoxy bases bonding adhesive etc., complete with all lead and lift,
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -Polyurethane foam (PUF) slab 50mm thick

41.8.3 Over deck insulation with Polyurethane foam (PUF) slab


Providing and fixing polyurethane foam (PUF) slab with PU slab density
36+/-2 kg/m3 insulation for over deck covered with two layers of 40mm
thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) using
12.50mm nominal size aggregates nd top layer of 10mm thick plaster with
cement mortar 1:3 finished with floating coat of neat cement, including
necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, Sqm 2064.00
epoxy bases bonding adhesive etc., complete with all lead and lift,
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -Polyurethane foam (PUF) slab 60mm thick

41.8.4 Over deck insulation with Polyurethane foam (PUF) slab


Providing and fixing polyurethane foam (PUF) slab with PU slab density
36+/-2 kg/m3 insulation for over deck covered with two layers of 40mm
thick cement concrete screed with mix proportion 1:1.5:3 (M20grade) using
12.50mm nominal size aggregates nd top layer of 10mm thick plaster with
cement mortar 1:3 finished with floating coat of neat cement, including
necessary polymerized plaster reinforced with glass fibre mesh for PUF slab, Sqm 2976.00
epoxy bases bonding adhesive etc., complete with all lead and lift,
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -Polyurethane foam (PUF) slab 70mm thick

Page No:378
41.9.1 Over deck insulation with Polyurethane foam (PUF) spray
Providing and fixing over deck insulation with cast insitu polyurethane
foam (PUF) spray with PU foam spray including necessary fasteners etc.,
complete covered with two layers of 40mm thick cement concrete screed
with mix proportion 1:1.5:3 (M20grade) using 12.50mm nominal size
aggregates nd top layer of 10mm thick plaster with cement mortar 1:3
finished with floating coat of neat cement, including necessary polymerized
plaster reinforced with glass fibre mesh for PUF slab, epoxy bases bonding Sqm 2004.00
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Over deck
insulation with polyurethane foam (PUF) spray 40mm thick

Page 257 of 375


41.9.2 Over deck insulation with Polyurethane foam (PUF) spray
Providing and fixing over deck insulation with cast insitu polyurethane
foam (PUF) spray with PU foam spray including necessary fasteners etc.,
complete covered with two layers of 40mm thick cement concrete screed
with mix proportion 1:1.5:3 (M20grade) using 12.50mm nominal size
aggregates nd top layer of 10mm thick plaster with cement mortar 1:3
finished with floating coat of neat cement, including necessary polymerized
plaster reinforced with glass fibre mesh for PUF slab, epoxy bases bonding Sqm 2163.00
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Over deck
insulation with polyurethane foam (PUF) spray 50mm thick

41.9.3 Over deck insulation with Polyurethane foam (PUF) spray


Providing and fixing over deck insulation with cast insitu polyurethane
foam (PUF) spray with PU foam spray including necessary fasteners etc.,
complete covered with two layers of 40mm thick cement concrete screed
with mix proportion 1:1.5:3 (M20grade) using 12.50mm nominal size
aggregates nd top layer of 10mm thick plaster with cement mortar 1:3
finished with floating coat of neat cement, including necessary polymerized
plaster reinforced with glass fibre mesh for PUF slab, epoxy bases bonding Sqm 2745.00
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Over deck
insulation with polyurethane foam (PUF) spray 60mm thick

41.9.4 Over deck insulation with Polyurethane foam (PUF) spray


Providing and fixing over deck insulation with cast insitu polyurethane
foam (PUF) spray with PU foam spray including necessary fasteners etc.,
complete covered with two layers of 40mm thick cement concrete screed
with mix proportion 1:1.5:3 (M20grade) using 12.50mm nominal size
aggregates nd top layer of 10mm thick plaster with cement mortar 1:3
finished with floating coat of neat cement, including necessary polymerized
plaster reinforced with glass fibre mesh for PUF slab, epoxy bases bonding Sqm 3327.00
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Over deck
insulation with polyurethane foam (PUF) spray 70mm thick

41.10.1 Under deck insulation with Expanded Polystyrene(EPS)


Providing and fixing expanded polystyrene (EPS) board using aluminium
strips 20mm wide for under deck thermal insulation including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM Sqm 667.00
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 50mm thick

41.10.2 Under deck insulation with Expanded Polystyrene(EPS)


Providing and fixing expanded polystyrene (EPS) board using aluminium
strips 20mm wide for under deck thermal insulation including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 820.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 70mm thick

41.10.3 Under deck insulation with Expanded Polystyrene(EPS)


Providing and fixing expanded polystyrene (EPS) board using aluminium
strips 20mm wide for under deck thermal insulation including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 973.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 90mm thick

Page 258 of 375


41.10.4 Under deck insulation with Expanded Polystyrene(EPS)
Providing and fixing expanded polystyrene (EPS) board using aluminium
strips 20mm wide for under deck thermal insulation including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 1123.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 110mm thick

41.10.5 Under deck insulation with Expanded Polystyrene(EPS)


Providing and fixing expanded polystyrene (EPS) board using aluminium
strips 20mm wide for under deck thermal insulation including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 1199.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 120mm thick

41.10.6 Providing and fixing expanded polystyrene (EPS) 30mm thick with density
20kg/m3 for under deck thermal insulation including necessary fasteners
etc., complete (excluding cost of screed concrete which is to be measured
and paid seperately) with all lead and lift, transportation charges, loading Sqm 515.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per direction of engineer incharge of the work.

41.10.7 Providing and fixing expanded polystyrene (EPS) 40mm thick with density
20kg/m3 for under deck thermal insulation including necessary fasteners
etc., complete (excluding cost of screed concrete which is to be measured
and paid seperately) with all lead and lift, transportation charges, loading Sqm 589.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per direction of engineer incharge of the work.

41.10.8 Providing and fixing expanded polystyrene (EPS) 60mm thick with density
20kg/m3 for under deck thermal insulation including necessary fasteners
etc., complete (excluding cost of screed concrete which is to be measured
and paid seperately) with all lead and lift, transportation charges, loading Sqm 744.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per direction of engineer incharge of the work.

41.10.9 Providing and fixing expanded polystyrene (EPS) 75mm thick with density
20kg/m3 for under deck thermal insulation including necessary fasteners
etc., complete (excluding cost of screed concrete which is to be measured
and paid seperately) with all lead and lift, transportation charges, loading Sqm 859.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per direction of engineer incharge of the work.

Page No. 379


41.10.10 Providing and fixing expanded polystyrene (EPS) 100mm thick with density
20kg/m3 for under deck thermal insulation including necessary fasteners
etc., complete (excluding cost of screed concrete which is to be measured
and paid seperately) with all lead and lift, transportation charges, loading Sqm 1048.00
unloading charges, all taxes, cost of all materials, labour, HOM complete as
per direction of engineer incharge of the work.

41.11.1 THERMAL INSULATION OF ROOF WITH EXPANDED POLYSTYRENE


Providing and fixing
expanded polystyrene with aluminium strips at every 600mm c/c over
existing false ceiling for thermal insulation of roofing including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 594.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. - Expanded
polystyrene (EPS) 50mm thick

Page 259 of 375


41.11.2 THERMAL INSULATION OF ROOF WITH EXPANDED POLYSTYRENE
Providing and fixing
expanded polystyrene with aluminium strips at every 600mm c/c over
existing false ceiling for thermal insulation of roofing including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 698.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. - Expanded
polystyrene (EPS) 70mm thick

41.11.3 THERMAL INSULATION OF ROOF WITH EXPANDED POLYSTYRENE


Providing and fixing
expanded polystyrene with aluminium strips at every 600mm c/c over
existing false ceiling for thermal insulation of roofing including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 808.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. - Expanded
polystyrene (EPS) 90mm thick

41.11.4 THERMAL INSULATION OF ROOF WITH EXPANDED POLYSTYRENE


Providing and fixing
expanded polystyrene with aluminium strips at every 600mm c/c over
existing false ceiling for thermal insulation of roofing including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 934.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. - Expanded
polystyrene (EPS) 110mm thick

41.11.5 THERMAL INSULATION OF ROOF WITH EXPANDED POLYSTYRENE


Providing and fixing
expanded polystyrene with aluminium strips at every 600mm c/c over
existing false ceiling for thermal insulation of roofing including necessary
fasteners etc., complete (excluding cost of screed concrete which is to be
measured and paid seperately) with all lead and lift, transportation charges, Sqm 917.00
loading unloading charges, all taxes, cost of all materials, labour, HOM
complete as per direction of engineer incharge of the work. - Expanded
polystyrene (EPS) 120mm thick

41.12.1 OVER DECK THERMAL INSULATION OF ROOF WITH EXPANDED


POLYSTYRENE
Providing and fixing expanded polystyrene (50mm thick) for over deck
thermal insulation of roofing including necessary fasteners etc., complete
covered with two layers of 40mm thick cement concrete screed with mix
proportion 1:1.5:3 (M20grade) using 12.50mm nominal size aggregates and
top layer of 10mm thick plaster with cement mortar 1:3 finished with
floating coat of neat cement, including necessary polymerized plaster Sqm 1604.00
reinforced with glass fibre mesh for PUF slab, epoxy based bonding
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 50mm thick

41.12.2 OVER DECK THERMAL INSULATION OF ROOF WITH EXPANDED


POLYSTYRENE
Providing and fixing expanded polystyrene (50mm thick) for over deck
thermal insulation of roofing including necessary fasteners etc., complete
covered with two layers of 40mm thick cement concrete screed with mix
proportion 1:1.5:3 (M20grade) using 12.50mm nominal size aggregates and
top layer of 10mm thick plaster with cement mortar 1:3 finished with
floating coat of neat cement, including necessary polymerized plaster Sqm 1695.00
reinforced with glass fibre mesh for PUF slab, epoxy based bonding
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 70mm thick

Page 260 of 375


41.12.3 OVER DECK THERMAL INSULATION OF ROOF WITH EXPANDED
POLYSTYRENE
Providing and fixing expanded polystyrene (50mm thick) for over deck
thermal insulation of roofing including necessary fasteners etc., complete
covered with two layers of 40mm thick cement concrete screed with mix
proportion 1:1.5:3 (M20grade) using 12.50mm nominal size aggregates and
top layer of 10mm thick plaster with cement mortar 1:3 finished with
floating coat of neat cement, including necessary polymerized plaster Sqm 1786.00
reinforced with glass fibre mesh for PUF slab, epoxy based bonding
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 90mm thick

41.12.4 OVER DECK THERMAL INSULATION OF ROOF WITH EXPANDED


POLYSTYRENE
Providing and fixing expanded polystyrene (50mm thick) for over deck
thermal insulation of roofing including necessary fasteners etc., complete
covered with two layers of 40mm thick cement concrete screed with mix
proportion 1:1.5:3 (M20grade) using 12.50mm nominal size aggregates and
top layer of 10mm thick plaster with cement mortar 1:3 finished with
floating coat of neat cement, including necessary polymerized plaster Sqm 1891.00
reinforced with glass fibre mesh for PUF slab, epoxy based bonding
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 110mm thick

41.12.5 OVER DECK THERMAL INSULATION OF ROOF WITH EXPANDED


POLYSTYRENE
Providing and fixing expanded polystyrene (50mm thick) for over deck
thermal insulation of roofing including necessary fasteners etc., complete
covered with two layers of 40mm thick cement concrete screed with mix
proportion 1:1.5:3 (M20grade) using 12.50mm nominal size aggregates and
top layer of 10mm thick plaster with cement mortar 1:3 finished with
floating coat of neat cement, including necessary polymerized plaster Sqm 1912.00
reinforced with glass fibre mesh for PUF slab, epoxy based bonding
adhesive etc., complete with all lead and lift, transportation charges,
loading unloading charges, all taxes, cost of all materials, labour, HOM etc.,
complete as per direction of engineer incharge of the work. -Expanded
polystyrene (EPS) 120mm thick

Page No. 380


41.13.1 OVER DECK WITH GLASS WOOL
Providing and fixing resin bonded glass wool slab having density
48kgs/cum for over deck insulation of roofing with glass wool including
necessary fasteners GI wire & mesh etc., complete covered with one layers
of 40mm thick cement concrete screed with mix proportion 1:1.5:3
(M20grade) using 12.50mm nominal size aggregates and top layer of 10mm
thick plaster with cement mortar 1:3 finished with floating coat of neat
cement, including necessary polymerized plaster reinforced with glass fibre Sqm 1174.00
mesh for PUF slab, epoxy based bonding adhesive etc., complete with all
lead and lift, transportation charges, loading unloading charges, all taxes,
cost of all materials, labour, HOM etc., complete as per direction of engineer
incharge of the work. -Glass wool slab 12mm thick

41.13.2 OVER DECK WITH GLASS WOOL


Providing and fixing resin bonded glass wool slab having density
48kgs/cum for over deck insulation of roofing with glass wool including
necessary fasteners GI wire & mesh etc., complete covered with one layers
of 40mm thick cement concrete screed with mix proportion 1:1.5:3
(M20grade) using 12.50mm nominal size aggregates and top layer of 10mm
thick plaster with cement mortar 1:3 finished with floating coat of neat
cement, including necessary polymerized plaster reinforced with glass fibre Sqm 1349.00
mesh for PUF slab, epoxy based bonding adhesive etc., complete with all
lead and lift, transportation charges, loading unloading charges, all taxes,
cost of all materials, labour, HOM etc., complete as per direction of engineer
incharge of the work. -Glass wool slab 25mm thick

Page 261 of 375


41.13.4 OVER DECK WITH GLASS WOOL
Providing and fixing resin bonded glass wool slab having density
48kgs/cum for over deck insulation of roofing with glass wool including
necessary fasteners GI wire & mesh etc., complete covered with one layers
of 40mm thick cement concrete screed with mix proportion 1:1.5:3
(M20grade) using 12.50mm nominal size aggregates and top layer of 10mm
thick plaster with cement mortar 1:3 finished with floating coat of neat
cement, including necessary polymerized plaster reinforced with glass fibre Sqm 1500.00
mesh for PUF slab, epoxy based bonding adhesive etc., complete with all
lead and lift, transportation charges, loading unloading charges, all taxes,
cost of all materials, labour, HOM etc., complete as per direction of engineer
incharge of the work. -Glass wool slab 50mm thick

41.14.1 OVER DECK WITH ROCK WOOL


Providing and fixing ROCK wool 25mm resin bonded rock wool
slab having density 48kgs/cum for over deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete (excluding cost of screed
concrete which is to be measured and paid seperately) with all lead and lift, Sqm 565.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -ROCK wool slab 25mm thick

41.14.2 OVER DECK WITH ROCK WOOL


Providing and fixing ROCK wool 25mm resin bonded rock wool
slab having density 48kgs/cum for over deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete (excluding cost of screed
concrete which is to be measured and paid seperately) with all lead and lift, Sqm 603.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -ROCK wool slab 40mm thick

41.14.3 OVER DECK WITH ROCK WOOL


Providing and fixing ROCK wool 25mm resin bonded rock wool
slab having density 48kgs/cum for over deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete (excluding cost of screed
concrete which is to be measured and paid seperately) with all lead and lift, Sqm 626.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -ROCK wool slab 50mm thick

41.14.4 OVER DECK WITH ROCK WOOL


Providing and fixing ROCK wool 25mm resin bonded rock wool
slab having density 48kgs/cum for over deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete (excluding cost of screed
concrete which is to be measured and paid seperately) with all lead and lift, Sqm 666.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -ROCK wool slab 65mm thick

41.14.5 OVER DECK WITH ROCK WOOL


Providing and fixing ROCK wool 25mm resin bonded rock wool
slab having density 48kgs/cum for over deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete (excluding cost of screed
concrete which is to be measured and paid seperately) with all lead and lift, Sqm 692.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -ROCK wool slab 75mm thick

41.14.6 OVER DECK WITH ROCK WOOL


Providing and fixing ROCK wool 25mm resin bonded rock wool
slab having density 48kgs/cum for over deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete (excluding cost of screed
concrete which is to be measured and paid seperately) with all lead and lift, Sqm 759.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM etc., complete as per direction of engineer incharge
of the work. -ROCK wool slab 100mm thick

Page 262 of 375


41.15.1 UNDER DECK INSULATION WITH GLASS WOOL
Providing and fixing glass wool resin bonded glass
wool slab having density 48kgs/cum for under deck insulation of roofing
including necessary fasteners GI wire & mesh etc., complete (excluding cost
of screed concrete which is to be measured and paid seperately) with all Sqm 898.00
lead and lift, transportation charges, loading unloading charges, all taxes,
cost of all materials, labour, HOM scaffolding etc., complete -Glass wool
slab 25mm thick

41.15.2 UNDER DECK INSULATION WITH GLASS WOOL


Providing and fixing glass wool resin bonded glass
wool slab having density 48kgs/cum for under deck insulation of roofing
including necessary fasteners GI wire & mesh etc., complete (excluding cost
of screed concrete which is to be measured and paid seperately) with all Sqm 1075.00
lead and lift, transportation charges, loading unloading charges, all taxes,
cost of all materials, labour, HOM scaffolding etc., complete -Glass wool
slab 40mm thick

Page No. 381


41.16.1 UNDER DECK WITH ROCK WOOL
Providing and fixing ROCK wool resin bonded glass wool slab
having density 48kgs/cum for under deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete with all lead and lift, Sqm 585.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM scaffolding etc., complete -ROCK wool slab 25mm
thick

41.16.2 UNDER DECK WITH ROCK WOOL


Providing and fixing ROCK wool resin bonded glass wool slab
having density 48kgs/cum for under deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete with all lead and lift, Sqm 628.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM scaffolding etc., complete -ROCK wool slab 40mm
thick

41.16.3 UNDER DECK WITH ROCK WOOL


Providing and fixing ROCK wool resin bonded glass wool slab
having density 48kgs/cum for under deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete with all lead and lift, Sqm 655.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM scaffolding etc., complete -ROCK wool slab 50mm
thick

41.16.4 UNDER DECK WITH ROCK WOOL


Providing and fixing ROCK wool resin bonded glass wool slab
having density 48kgs/cum for under deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete with all lead and lift, Sqm 703.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM scaffolding etc., complete -ROCK wool slab 65mm
thick

41.16.5 UNDER DECK WITH ROCK WOOL


Providing and fixing ROCK wool resin bonded glass wool slab
having density 48kgs/cum for under deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete with all lead and lift, Sqm 733.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM scaffolding etc., complete -ROCK wool slab 75mm
thick

41.16.6 UNDER DECK WITH ROCK WOOL


Providing and fixing ROCK wool resin bonded glass wool slab
having density 48kgs/cum for under deck insulation of roofing including
necessary fasteners GI wire & mesh etc., complete with all lead and lift, Sqm 812.00
transportation charges, loading unloading charges, all taxes, cost of all
materials, labour, HOM scaffolding etc., complete -ROCK wool slab
100mm thick

Page No. 382

Page 263 of 375


9 9 Cum 757 1618.13 1224924.41
10 10 Cum 555 1944.64 1079275.20
11 11 Sqm 2222 35.02 77814.44
12 12 Sqm 2169 23.69 51383.61
13 13 Cum 163 7687.92 1253130.96
14 14 Sqm 2169 14.42 31276.98
15 15 Cum 87 8915.68 775664.16
4493469.76
Sl No. Code No. Name Unit
1 0009 Adhesive(for linoiling flooring) Kg
2 0509 Adhesive for tiles Kg
3 0514 Adhesive for joints Kg
4 0022 Bees Wax Kg
5 0513 High bond tile adhesive for vitrified tiles Kg
6 2008 Kgs
7 2047 Ball Adhesives Kgs
8 0387 Shellac Kgs
9 0054 Brick bats 25 to 100 mm Cum
10 0055 Brick aggregate 20 mm(Nominal) Cum
11 0056 Brick aggregate 25 mm(Nominal) Cum

0064
12 Burnt brick class designation 35 ( Non Modular) Ground Moulded 100 Nos.
13 0503 Burnt brick class designation 35 (modular) 100 Nos.
14 0488 Table moulded bricks class designation 50 (non modular) 100 Nos.
15 0504 Table moulded class designation 50 (modular) 100 Nos.
16 0505 Wire cut bricks of class designation 75 (non modular) 100 Nos.
17 0506 Wire cut bricks of class designation 75 ( modular) 100 Nos.
18 0311 100 Nos.
19 0391 Solid blocks (concrete 40x20x20cms) 100 Nos.
20 0501 100 Nos.
21 0502 100 Nos.
22 0497 100 Nos.
23 0498 Hollow concrete blocks (40x20x15cms) 100 Nos.
24 0499 100 Nos.
25 2109 Pre-cast clay hollow bricks 40cm x 20cm x 20cm Each
26 2110 Each
27 Each
2111
28 0175 100 mm and down nominal size Cum
29 0734 53 mm nominal size Cum
30 0750 40 mm nominal size Cum
31 0060 30 mm nominal size Cum
32 0800 25 mm nominal size Cum
33 0749 20 mm nominal size Cum
34 0058 12.5 mm nominal size Cum
35 0057 10 mm nominal size Cum
36 0707 6 mm nominal size Cum
37 0803 Fine aggregate 2.36 mm nominal size Cum
38 0762 Key aggregates 22.4 to 2.8 mm Cum
39 0746 Filter media stone aggregate Cum
40 0904 Coarse aggregates 53 mm Cum
41 0906 Crushed aggregates 37.5mm Cum
42 0912 Crushed coarse aggregate (Supply of hand broken aggregates) Cum
43 0919 Cum
44 0921 Crushed stone aggregate 13.2mm to 10mm Cum
45 0922 Cum
46 0926 Crushed aggregate 9.5mm to 4.75mm Cum
47 567 Tonne
48 0732 Crushed stone chippings 11.2 mm Cum
49 0733 Crushed stone chippings 13.2 mm Cum
50 0400 Stone dust / Grit Cum
51 0815 Crushed stone chipping 5.6 mm size cum
52 0819 Lime Stone Dust Tonne
53 0287 Pea size gravel/6mm and down stone grit cum
54 0334 Sand/ Artificial Sand/ Manufactured Sand cum
55 0551 Ordinary earth cum
56 0731 Sand / Crushed Sand cum
57 0751 Granular material cum
58 0752 Gravel 2.36 mm cum
59 0772 Natural sand 5.6 to 75 micron cum
60 0781 Quartz sand Kgs
61 0037 Bond stones 20cms x 20cms x 45cms Each
62 0039 Boulders Cum
63 0066 Burnt stone slabs 10cms thick Sqm
64 0174 Granite stone slabs fine dressed 40 mm thic Sqm
65 0330 Rubble stones Cum
66 0390 Size stone 20x20x25 cm Each
67 0401 Stone slab 10 to 12 cm thick Sqm
68 0720 Bond stone 20x20x45 cm Each
69 0780 Quarry spalls Cum
70 0789 Size stone 20x20x25 cms Each
71 0790 Spall (jelly used for packing) Cum
72 0793 Rough stones Cum
73 0794 Stone boulders Cum
74 0795 Stone spalls Cum
75 0939 Stone with minimum size of 200mm Cum
76 0010 Aluminium beading Kgs
77 0011 Aluminium handles - 15mm Each
78 0012 Aluminium hinges 75 mm length Each
79 0013 Aluminium stays Each
80 0014 Aluminium tower bolt - 20 cm Each
81 0017 Aluminium sheet for strips Sqm
82 0018 Aluminium window frame section 1.2 mm thick Kgs
83 0522 Aluminium Composite panel of approved colour straight portion Sqm
84 0533 Aluminium frame section Kgs
85 0544 Aluminium composite panel of curved portion Sqm
86 0860 Aluminium studs 100 x 100mm fitted with lense reflectors nos
Aluminium sheeting fixed with encapsulated lens type reflective
0942
87 sheeting of size 0.9sqm Sqm
Aluminium alloy/galvanised steel/ Galvanised MS plate including
0943
88 5% wastage Tonne
Aluminium alloy plate, 2mm thick, fixed with high intensity grade
0944
89 sheeting vide Clause 801.3 Sqm
90 2069 Alluminium anodised profile top cap beading m
91 0007 AC sheet 6 mm thick semi corrugated Sqm
92 0008 AC sheet 6 mm thick semi trafford Sqm
93 0327 Ridges (AC sheet) Pair
94 0717 Bitumen 80/100 Grade bulk Tonne
95 835 Bitumen 80/100 Packed Tonne
96 0814 Bitumen 60/70 Grade Tonne
97 836 Bitumen 60/70 Packed Tonne
98 0030 Bitumen 85/25 Grade Tonne
99 0820 Bitumen 30/40 Grade Tonne
100 0730 CRMB Tonne
101 0806 NRMB 70 Tonne
102 0735 Cut back MC 70 Tonne
103 0718 Bitumen emultion Tonne
104 0031 Bitumen felt (hersian based) Sqm
105 0032 Bitumen washer Each
106 0109 Coal tar Sqm
107 0108 Coal tar paint L
108 0035 Blown or residual bitumen Tonne
109 0807 Polymer MB 70 Tonne
110 0736 Detonator Each
111 0738 Drill bits Nos
112 0786 Safety fuse wire Coil
113 0791 Gelatin Kg
114 0002 12 mm thick pre laminated board (Novapan) exterior grade Sqm
Prelaminated board 19 mm thick of approved lamination on both
0312
115 side Sqm
Prelaminated board of approved lamination on one side and
0313
116 balancing white colour Sqm
117 0301.a a.Plywood 12 mm thick (Commercial) Sqm
118 0301.b b.Plywood 19 mm thick (Commercial) Sqm
119 0301.c c.Plywood 25 mm thick (Commercial) Sqm
120 0301.d d.Sheet 6 mm thick (Commercial) Sqm
121 0293 Plain particle board Sqm
122 0180 Hard board 45 x 45 mm size Sqm
123 0181 Hard board 600 x 450 mm size Sqm
124 0955 Pre-moulded asphalt filler board Sqm
125 2006 12mm plywood Sqm
126 2007 4mm thick veneer Sqm
127 2009 19mm Plyboards Sqm
128 2010 1.5mm Laminate Sqm
129 2090 5mm PVC sheet Sqm
130 2099 5mm BS prelam PVC sheet Sqm
131 2100 5mm SS prelam PVC shee Sqm
132 2101 2mm PVC sheet Sqm
133 0084 Cement Kg
134 0439 White cement Kg
135 1557 Portland Slag Cement (PSC)/ Portland Pozzolona Cement (PPC) Kg
136 1558 Ground Granulated blast furnace slag(GGBS) Kg
137 0088 Chequered mosaic tiles grey Sqm
138 0089 Chequered mosaic tiles light shade Sqm
139 0090 Chequered mosaic tiles medium shade Sqm
140 0091 Chequered mosaic tiles white colour Sqm
141 0110 Cobble stone 60 mm thick Sqm
142 0111 Cobble stone 75 mm thick Sqm
143 0116 Cuddapah slab 2.5 cm to 4 cm thick Sqm
144 0176 Gray colour mosaic tiles Sqm
145 0213 Light shade mosaic tiles Sqm
146 0228 Machine cut granite stone slab 40 mm Sqm
147 0229 machine polished granite stone slab 20 mm Sqm
148 0231 marble chips Kgs
149 0234 Marble dust Cum
150 0235 marble powder Cum
151 0237 marble slab 20 mm thick Sqm
152 0248 metallic floor hardner Kgs
153 0386 shahabad slabs 2.5 cm to 4 cm thick Sqm
154 0448 white mosaic tiles Sqm
155 0507 vitrified tiles 10 mm thick 600X600 mm granolite finish Sqm
156 0508 vitrified tiles 600X600 mm 10 mm thick Sqm
157 0545 20 mm thick hassan green granite Sqm
158 0546 ceramic tiles 30X30 cms Sqm
159 0510 Grout for vetrified tiles Kgs
160 0511 Spacers for Vetrified tiles No
161 0512 Sealer for vetrified tiles Sqm
162 0515 Prepolished Grey granite 20 mm thick Sqm
163 0517 20 mm thick Ruby red granite Sqm
164 0518 20 mm thick grey granite Sqm
165 0519 20 mm thick Shiva gold granite Sqm
166 0520 20 mm thick Black granite Sqm
167 0521 Prepolished black granite 20 mm thick Sqm
168 0523 Prepolished Water cut grey granite Sqm
169 0725 Chequerred cement concrete tiles Sqm
170 0416 Tandur blue slabes 2.5cms to 4 cm thick Sqm
171 0545 20mm thick Hassan green granite Sqm
172 2076 Lakared granite Sqm
173 2085 Sadarahalli flammed granite 40mm Sqm
174 2086 Sadarahalli pre polished granite 20mm Sqm
175 2108 Black granite 40mm thick Sqm
176 0112 Colour glazed tiles 15 x 15 cms 10mm thick Each
177 0113 White glazed tiles 15 x 15 cms 6mm thick Each
178 0186 Hersian cloth for using in tiles as reinforcement sqm
179 0217 Linolium sheet for tile 30 cmsx30cms sqm
180 0464 Yelahanka tiles of size 250x250 mm Each
181 0481 Mangalore tiles first class and special tile for ridges and hips nos
182 0485 Medium shade mosaic tiles sqm
183 0486 Ceramic tiles 15 cms x 15 cms sqm
184 0444 White glazed tiles 15 cms x 15 cm , 10 mm thick plain Each
185 0445 Color glazed tiles 15 cm x 15 cm, 10 mm thick anti skid Each
186 578 Pre polished grey granite tile 10mm sqm
187 579 Pre polished black granite tile 10mm sqm
188 2073 Concrete designer tiles sqm
189 2074 Ceramic tiles of 300x 600mm sqm
190 2075 Ceramic tiles of 300x 450mm sqm
191 2042 Border tiles 30x10cms Each
192 2043 Glazed tiles 300 x 450 sqm
193 2026 Ceramic tiles 400 x 400mm sqm
194 0495 Ready Mix Concrete M 20 (1:1.5:3) cum
195 0496 Ready Mix Concrete M 25 (1:1:2) cum
196 2200 Ready Mix Concrete M 30 cum
197 2201 Ready Mix Concrete M 35 cum
198 2202 Ready Mix Concrete M 40 cum
199 0003 18 gauge 75 mm MS laths of 2.8 m length Nos
200 0004 Z section Kgs
201 0019 Angle iron 40x40x6mm Kgs
202 0087 Channels 25x25x6 mm Kgs
203 0187 High tension coil oxidised MS Each
204 0203 Hooks oxidised MS 150 mm Each
205 0221 M.S. flat 30 cmx25mmx3mm Kgs
206 0223 M.S. Round Bright bars 20mm Q
207 0224 M.S. Square Bright bars 20mm Q
208 0249 Mild steel 6 mm dia Kgs
209 0250 Mild steel bars Q
210 0252 MS channels Kgs
211 0255 MS flats 20 mm x 6 mm Kgs
212 0257 MS plates Kgs
213 0258 MS rods Kgs
214 0259 MS sheet 1 mm thick Kgs
215 0260 MS sheet 20 gauge Kgs
216 0262 MS tees Kgs
217 0264 Mullion section (MS) Kgs
218 0288 Pig lead Kgs
219 0414 T section MS Kgs
220 0484 M.S.Shoes Kgs
221 0547 Expanded metal 12.5 mm to 25 mm -14 G sqm
222 0714 Bearing plates Tonne
223 0716 Binding wire Kgs
224 0723 Cast Steel Kgs
225 0724 Cast Steel rocker assembly Kgs
226 0739 Edge beams of steel of special shape and section Kgs
227 0748 Forges Steel (2 rollers) Kgs
228 0756 High Tensile steel wires/strands Tonne
229 0757 High Tensile strands q
230 0758 Thermo Mechanically Treated bars (TMT bars) Tonne
231 0759 ISMC 1002.806x1.05 Tonne
232 0763 Mild steel q
233 0764 Mild steel anchors Kgs
234 0765 Mild steel matrix including wastage Kgs
235 0766 Mild steel plate(Galvanised) Tonne
236 0767 MS bars Tonne
237 0770 MS flats Tonne
238 0771 Ms gratings 260 mmx 260 mm Each
239 0777 Pile shoes-Ci Kgs
240 0778 Pile shoes-MS Kgs
241 0792 Stainless steel 304 grade Kgs
242 0862 Mild Steel pipe 100mm dia 2.5mm thick m
243 0863 Mild Steel pipe 25mm dia 2.5mm thick m
244 0864 CGI sheets Kgs
245 0865 Angle iron 45x45x5mm Kgs.
246 0866 M.S sheet 300mm wide,2.5mm long and 2.6mm thick Kgs.
247 0867 Angle iron 50x50x2mm long Kgs.
248 0868 M.S sheet of 12 SWG, 3 Nos of 200mm width and 4m length Kgs.
249 0870 Steel drum 300mm dia 1.2m high/empty Nos.
250 0940 Kgs.
251 0941 Kgs.
Corrugated sheet, 3mm thicken "W" beam section railing, 4.5m in
0957 Kgs.
252 length.
253 0958 Channel post 150 x 75 x 5mm Kgs.
254 0959 Channel 150 x 75 x 5 mm Kgs.
Structural steel in plates, angles, Galvanised structural steel plate
0963
255 etc.,including 5% wastage Tonne
256 0972 RS joist 100 x 75mm Kgs.
257 0973 Struts - 2 Nos. for terminal posts, 2m long each 2 x 2 x 11.50 Kgs.
Tie 2 Nos. of 8mm steel plate, 1.5sqm each for terminal posts at
0974
258 62.80kg/sqm(2x1.5) Kgs.
259 0975 Steel wire rope 40mm Kgs.
260 0976 Mild steel pipe 25mm dia, 2.5mm thick m
MS sheet for 600 x 300 x3mm rectangular vane, one number at 24
0977
261 kg/sqm Kgs.
MS sheet for 250mm dia circular vane 3mm thick, 4 number at 24
0978
262 kg/sqm Kgs.
263 0979 MS sheet 3mm thick at 24kg/sqm Kgs.
Galvanised angle sections 100mm x 10mm of 12mm thickness
0981 weldable structural steel as per IS:2062.2 Nos. of 12m length
264 each at 17.7 kg/m Kgs.
265 0988 Helical pipes 600mm diametre m
266 0989 Tie rodes 20mm diametre Kgs.
Steel circular hollow pole of standard specification for street
1100
267 lighting to mount light at 9m height above road level. Each
Tube anchorage set complete with bearing plate, permanent
1510
268 wedges etc. No.
269 1512 Bearing No.
270 1513 Bearing rocker & Roller No.
271 1516 Sheating duct ID 66mm Tonne
272 1519 32mm mild steel dowel bars of grade s240 Tonne
273 1520 16mm deformed steel tie bars fo grade S 415 Tonne
274 1534 20 x 5 mm diaganals Kgs.
Cast steel rocker bearing assembly of 250 tonne design load
1553 capacity duly painter complete with all leads components as per
275 drawing and specifications Nos.
PTFE sliding plate bearing assembly of 80 t. design load capacity
1554 duly painted complete with all its components as per drawing &
276 technical specification. Nos.
277 558 MS angles 65 X 65 X 6 mm 34.7 Kgs Kgs.
278 562 38 mm dia of 14 guage MS black pipe m
279 561 20 mm dia hold fast Rod Nos.
280 571 Stainless steel strips m
281 573 M S Clamps for Shoe Kgs.
282 576 Steel column 400x250 mm (ISHB Series) Tonne
283 577 Forged steel rollar bearing of 250 tonne No.
Steel circular Hollow pole of standard specification for street
1103
284 lighting to mount light at 5m height above road level. each
285 2022 MS flat 12x75mm Kgs
286 2021 M S Tubes Kgs
287 2027 50mm dia M.S. Hollow pipe B Class 14 Gauge Kgs
288 2028 20mm x 20mm vertical M.S. Square Rod Kgs
289 2015 Gusset plates 6mm thick Kgs
290 2016 Base plate/ base plate Kgs
291 2018 Anchor Bolts 750mm No.
292 2029 12x12 M.S. Square Rod Kgs
293 2030 16x16mm M.S. Square Rod Kgs
294 2031 40x6mm M.S. Flat Kgs
295 2032 12mmx6mm M.S. Flat Kgs
296 2033 Cast iron spike Nos.
297 2034 50x50 M.S. Hollow pipe Kgs
298 2036 36mm x 6mm M.S. Flat Kgs
299 2038 Kgs
300 2039 Kgs
301 2040 5" dia 5mm thick M.S. plate Nos.
302 2067 MS pipes of 80mm to 100mm dia Kgs
303 2068 RMS Gusset plate Kgs
304 2078 Stainless steel tubes 40mm, 14 gauge Kgs
305 2091 M.S. Tube m
306 489 M.S. 20mm Square bar q
MS angle iron 40mm x 40mm x 6mm, 23 metre in length at 3.5 kg
0949 Kgs
307 pe metre
MS angle iron 50mm x 50mm x 6mm, 33.8 metre in length at 4.5
0950 Kgs
308 kg per metre.
309 0951 Runner flat 50 x 5mm Kgs
Welded steel with fabric 75 x 50mm mesh at 4kg/ sqm, 4 x 30 x
0952 Kgs
310 1.2+5% wastage
311 0953 Steel pipe 50mm external dia as per IS:1239 2.5mm thick m
Medium wt. steel channel (ISMC Series) 100mm x 50mm,10.8
0954 Kgs
312 metre length at 9.2 kg per m
313 0115 Corner beads 45x45 mm m
314 0190 honne wood Cum
315 0191 honne wood beading 10 mm wide m
316 0193 honne wood beading 20x20 mm m
317 0194 Honne wood scantling Cum
318 0195 Honne wood scantling for styles and rails 30mm thick Cum
319 0196 Honne wood scantling for styles and rails 35mm thick Cum
320 0198 Honne wood planks for shutters(frame) 35mm thick cum
321 0200 Honne wood planks for panels 20mm thick cum
322 0201 Honne wood battens cum
323 0202 Honne wood beads cum
324 0205 Jungle wood battens 25mm x 40mm cum
325 0206 Jungle wood battens 50mm x 40mm cum
326 0207 Jungle wood runners and planks cum
327 0208 Jungle wood runners and planks cum
328 0209 Jungle wood scantling cum
329 0238 mathi or Nandi wood cum
330 0239 mathi or Nandi wood planks for panels 20mm thick cum
331 0240 mathi or Nandi wood scantlings for styles and rail 25mm thick cum
332 0241 mathi/Nandi wood cum
333 0242 mathi/Nandi wood battens cum
334 0243 mathi/Nandi wood beadings 10mm wide m
335 0244 mathi/Nandi wood planks for panels 25mm thick m
336 0245 mathi/Nandi wood scantling cum
337 0246 mathi or Nandi wood scantlings for styles and rails 30mm thick cum
338 0266 Nandi wood reepers 50x25 mm m
339 0269 NUWUD (MDF) panel filling 19 mm thick Sqm
340 0286 Panel filled with NUWUD (MDF) board 12 mm thick Sqm
341 0294 planks for filling Sqm
342 0332 Sal wood cum
343 0333 Sal wood battens cum
344 0389 silver oak or equivalent planks 38 mm thick cum
345 0417 Teak wood cum
346 0418 Teak wood beading 10mm wide m
347 0419 Teak wood beading 20x20 mm m
348 0420 Teak wood cum
349 0421 Teak wood gutties Big Each
350 0422 Teak wood planks for panels 25 mm thick cum
351 0423 Teak wood reepers 50x25 mm m
352 0424 Teak wood scantling for styles and rails 30mm thick cum
353 0425 Teak wood scantling for styles and rails 35mm thick cum
354 0426 Teak wood beads cum
355 0429 TW beading for fixing glass m
356 0463 Wooden strips of I class teak wood (25 mm/6mm) 4mtr. Long Each
357 0490 Jungle wood reepers 50x25 mm m
358 0706 25mm thick silver oak planks Sqm
359 0798 Wooden blocks Nos
360 0462 Wooden cleats Each
361 0080 Casuarina bellies 75 to 100 mm dia m
362 0081 Casuarina poles 100 to 150 mm m
363 0082 Casuarina poles 75 to 100 mm dia m
364 0869 Jungle wood cum
365 0872 Wooden staff for fastening of flag 25mmdia, one m long Each
366 0961 Wooden ballies 8"dia & 9m long No.
367 0962 Wooden ballies 2"dia for bracing m
368 2002 50x35mm salwood crunnel cum
369 2003 Teakwood gutties Small Nos.
370 2011 Teak wood beading 10mm wide m
371 0006 5.5mm thick plain glass Sqm
372 0170 Glass shelf 600x120mm with guard rail Each
373 0171 Glass strips Sqm
374 0172 Glazing clips Kgs
375 0467 4mm thick plain glass Sqm
376 0324 Reeded glass 2 mm thick Sqm
377 0325 Reeded glass 3 mm thick Sqm
378 0538 Imported glass 6 mm thick Sqm
379 2012 12mm thick plain tuffened glass Sqm
380 2014 12mm thick frosted toughened glass Sqm
381 2071 Glass etching Sqm
382 0005 25 mm dia pulley (for alluminum sliding door) Each
383 0011 Aluminium handles - 15mm Each
384 0012 Aluminium hinges 75 mm length Each
385 0038 Bottom lock nail Each
386 0046 Brass screws 25 mm Each
387 0085 Center pulley Each
388 0086 Central ball bearing Each
389 0107 Cleat angles Each
390 0133 Door closure heavy duty floor mounting Each
391 0134 Door lock Each
392 0177 Gusset plates 3.15 mm thick Kgs
393 0178 Handles power coated 150 mm Each
394 0179 Handles to full width 2m long Each
395 0188 Hinges 5" heavy duty Each
396 0189 Hold fasts MS Each
397 0220 Locking arrangments Each
398 0222 M.S. holder bat clamp 32mm Each
399 0225 M.S stays and clamps for 200 mm length including bolts and nuts Each
400 0226 M.S stays and clamps for 50 mm length including bolts and nuts Each
401 0227 M.S stays and clamps for 75 mm length including bolts and nuts Each
402 0253 MS clamps Each
403 0254 MS cleats with bolts and nuts to rest on pile Each
404 0256 MS handles oxidised 150 mm Each
405 0261 MS side shed clamps Each
406 0265 Nail and screws Kgs
407 0314 Pulleys 38 mm dia Each
408 0326 Reeper nails 50 mm long Kgs
409 0384 Screws 40 mm Each
410 0388 Side guides Each
411 0399 Stays (MS) Each
412 0427 Tower bolt 300 mm long Each
413 0474 Pivots Nos
414 0540 Screws Nos
415 0537 Box cleats Nos
416 0541 Anchor Bolts Nos
417 0542 Galvanized L brackets Nos
418 0708 Steel inserts with stainless steel bolts and nuts Kgs
419 0719 Bolts and nuts Kgs
420 0768 MS bolts, nuts and washers Tonne
421 0710 Anchorages Each
422 0711 Anchor loops (IS 2062) Each
423 0712 Anchor plates (IS 2062) Each
424 0713 Anchorage sets Each
425 0094 Chrominum plated screw -25mm Each
426 0167 Gl 'j' or 'L' hook with nuts and bolts 8mm dia Each
427 0291 Pintels including welded pins Each
428 0492 C.P brass brackets Pair
429 2084 Hydraulic door clouser - aluminium body No.
430 0015 Aluminium paint L
431 0016 Aluminium paint primer (red oxide) L
432 0020 Anticorrosive bitumastic paint L
433 0033 Black Japan paint L
434 0131 Dark shade pigment Kgs
435 0132 Distemper primer L
436 0136 Dry Distumper Kgs
437 0137 Enamel metal paint L
438 0138 Enamel primer L
439 0214 Light shade pigment Kgs
440 0247 Medium shade pigment Kgs
441 0285 Paint remover L
442 0289 Pigment Kgs
443 0290 Pink primer paint L
444 0300 Plastic emulsion paint L
445 0320 Ready mix primer paint L
446 0321 Ready mix red lead paint L
447 0323 Red oxide Kgs
448 0430 undercoat flatting varnish L
449 0431 Unslaked lime qtl
450 0432 Varnish L
451 0433 Wall paint L
452 0435 Water proof cement paint Kgs
453 0438 Wax polish Kgs
454 0271 Oil bound distemper Kgs
455 0428 Turpentine Oil L
456 0543 Anodized M R F painting Sqm
457 0447 White lead paint for priming L
458 0461 Whitening Kgs
459 0528 Wax Kgs
460 0529 Sealer coat L
461 0530 Melamine Patty Kgs
462 0531 Melamine Polish L
463 0532 Thinner L
464 0775 Paint I quality(synthetic enamel paint) L
465 0776 Pigment Kgs
466 0784 Road marking paint L
467 0779 Primer L
468 0173 Gopi powder Kgs
469 0218 Linseed oil L
470 0219 Liquid wood filler L
471 0524 Sand paper Dozen
472 0525 50 size sand paper Dozen
473 0526 36 size sand paper Dozen
474 569 Primer Kgs.
475 0528 Wax Kgs
476 0529 Sealer Coat L
477 0530 Melamione Patty Kgs
478 0531 Melamione polish L
479 0532 Thinner L
480 0543 Anodized M R F painting Sqm
481 1504 Epoxy resin hardener mix for primne coat Kgs
482 2044 Light House Polish L
483 2045 Texture material Kgs
484 2046 Antifungal paint L
485 2050 Textured based white cement Kgs
486 2060 Soap powder Kgs
487 2081 Wiping cloths Each
488 2083 Soap oil / Phenol L
489 2092 Solvent cement adhesive L
490 0995 Water based paint for cement concrete surface L
491 0021 Asbestos cement pipes 75 mm dia of length 2 mtrs Each
492 0095 CI Bends 100 mm dia Each
493 0096 CI Bends 75 mm dia Each
494 0097 CI Bends 90 mm dia Each
495 0098 CI heads 100 mm dia Each
496 0099 CI pipes 100 mm dia of 1.8m length Each
497 0100 CI pipes 75 mm dia of 1.8m length Each
498 0101 CI shoes 100 mm dia Each
499 0102 CI shoes 110 mm dia Each
500 0103 CI shoes 75 mm dia Each
501 0146 G.I. Overflow pipe 20mm dia m
502 0147 G.I. Pipe 100 mm dia B class m
503 0148 G.I. Pipe 150 mm dia B class m
504 0149 G.I. Pipe 15 mm dia B class m
505 0150 G.I. Pipe 20 mm dia B class m
506 0151 G.I. Pipe 25 mm dia B class m
507 0152 G.I. Pipe 32 mm dia B class m
508 0153 G.I. Pipe 40 mm dia B class m
509 0154 G.I. Pipe 50 mm dia B class m
510 0155 G.I. Pipe 65 mm dia B class m
511 0156 G.I. Pipe 80 mm dia B class m
512 0157 G.I. Tee 32mm Each
513 0158 G.I. Tee 65mm Each
514 0169 GI washers Each
515 0182 HDPE 110mm dia, 4Kg/sqcm m
516 0183 HDPE 110mm outer dia, 2.5Kg/sqcm m
517 0184 HDPE 90mm outer dia, 4Kg/sqcm m
518 0185 HDPE 90mm outer dia, 2.5Kg/sqcm (rain down water pipes) m
519 0212 P.V.C. Lead connection pipe 32 mm dia (for wash basin) Each
520 0303 Polythylene pipes high density 32mm external dia m
521 0304 Polythylene pipes high density 40mm external dia m
522 0305 Polythylene pipes high density 50mm external dia m
523 0306 Polythylene pipes high density 20mm external dia m
524 0307 Polythylene pipes high density 25mm external dia m
525 0308 Polythylene pipes high density 32mm external dia m
526 0309 Polythylene pipes high density 40mm external dia m
527 0310 Polythylene pipes high density 50mm external dia m
Sand cast iron bend 100 mm dia with access door, washers, bolts
0335
528 and nuts Each
Sand cast iron bend 50 mm dia with access door, washers, bolts
0336
529 and nuts Each
Sand cast iron bend 75 mm dia with access door, washers, bolts
0337
530 and nuts Each
531 0338 Sand Cast iron pipe 100 mm dia 1.8m length Each
532 0339 Sand Cast iron pipe 50 mm dia 1.8m length Each
533 0340 Sand Cast iron pipe 75 mm dia 1.8m length Each
534 0342 Sand Cast iron plain bend 50 mm dia Each
535 0344 Sand Cast iron soil waste 114mm offsets 3" dia Each
536 0345 Sand Cast iron soil waste 152mm offsets 3" dia Each
537 0346 Sand Cast iron soil waste 230mm offsets 3" Each
Sand Cast iron soil waste double equal invert plain branches of
0347
538 required degree '100x100x100x100mm Each
Sand Cast iron soil waste double equal invert plain branches of
0348
539 required degree '50x50x50x50mm Each
Sand Cast iron soil waste double equal invert plain branches of
0349
540 required degree '75x75x75x75mm Each
Sand Cast iron soil waste double equal junction of required degree
0350
541 '100x100x100x100mm Each
Sand Cast iron soil waste double equal junction of required degree
0351
542 '50x50x50x50mm Each
Sand Cast iron soil waste double equal junction of required degree
0352 with access 'door, rubber washers bolts and nuts,
543 100x100x100x100mm Each
Sand Cast iron soil waste double equal junction of required degree
0353 with access 'door, rubber washers bolts and nuts,
544 100x100x50x50mm Each
Sand Cast iron soil waste double equal junction of required degree
0354 with access 'door, rubber washers bolts and nuts,
545 100x100x75x75mm Each

0355 Sand Cast iron soil waste double equal junction of required degree
546 with access 'door, rubber washers bolts and nuts, 75x75x75x75mm Each

0356 Sand Cast iron soil waste double equal junction of required degree
547 with access 'door, rubber washers bolts and nuts, 75x75x50x50mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0357
548 required degree '100x100x75mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0359
549 required degree '100x100x75x75mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0360
550 required degree '75x75x50mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0361
551 required degree '75x75x50x50mm Each
Sand Cast iron soil waste double unequal junction of required
0362
552 degree '100x100x50x50mm Each
Sand Cast iron soil waste double unequal junction of required
0363
553 degree '100x100x75x75mm Each
Sand Cast iron soil waste double unequal junction of required
0364
554 degree '75x75x50x50mm Each
Sand Cast iron soil waste single equal invert plain branches of
0365
555 required degree '100x100x100x100mm Each
Sand Cast iron soil waste single equal invert plain branches of
0366
556 required degree '50x50x50x50mm Each
Sand Cast iron soil waste single equal invert plain branches of
0367
557 required degree '75x75x75x75mm Each

0368 Sand Cast iron soil waste single equal junction of required degree
558 with access 'door, rubber washers bolts and nuts, 75x75x75mm Each
Sand Cast iron soil waste single equal junction of required degree
0369
559 with access door ' 100x100x100mm Each
Sand Cast iron soil waste single equal junction of required degree
0370
560 with access door ' 50x50x50mm Each
Sand Cast iron soil waste single equal junction of required degree
0371
561 with access door ' 75x75x75mm Each
Sand Cast iron soil waste single equal junction of required degree
0372 with access 'door, rubber washers bolts and nuts, '
562 100x100x100mm Each

0373 Sand Cast iron soil waste single equal junction of required degree
563 with access 'door, rubber washers bolts and nuts, ' 50x50x50mm Each
Sand Cast iron soil waste single unequal junction of required
0374
564 degree 100x100x50mm Each
Sand Cast iron soil waste single unequal junction of required
0375
565 degree 100x100x75mm Each
Sand Cast iron soil waste single unequal junction of required
0376
566 degree 75x75x50mm Each
Sand Cast iron soil waste single unequal junction of required
0377 degree with access 'door, rubber washers bolts and nuts,
567 100x100x50mm Each
Sand Cast iron soil waste single unequal junction of required
0378 degree with access 'door, rubber washers bolts and nuts,
568 100x100x75mm Each
Sand Cast iron soil waste single unequal junction of required
0379 degree with access 'door, rubber washers bolts and nuts,
569 750x75x50mm Each

0380 Sand Cast iron soil waste double equal junction of required degree
570 with access 'door, rubber washers bolts and nuts, 50x50x50x50mm Each
571 0381 Sand cast iron trap 100mm dia Each
572 0382 Sand cast iron trap 50mm dia Each
573 0383 Sand cast iron trap 75mm dia Each
574 0393 Special for overflow pipe Each
575 0402 Stoneware pipes 100mm dia 60 cms long Each
576 0403 Stoneware pipes 150mm dia 60 cms long Each
577 0404 Stoneware pipes 200mm dia 60 cms long Each
578 0405 Stoneware pipes 230mm dia 60 cms long Each
579 0406 Stoneware pipes 250mm dia 60 cms long Each
580 0407 Stoneware pipes 300mm dia 60 cms long Each
581 0408 Stoneware pipes 350mm dia 60 cms long Each
582 0409 Stoneware pipes 400mm dia 60 cms long Each
583 0410 Stoneware pipes 450mm dia 60 cms long Each
584 0476 100 mm dia asbestos dia cement pipe of length 2 mtrs Each
110 mm outer dia 2 kg/sqcm pressure pipe of approved make
0477
585 (PVC) m
110 mm outer dia 2.5 kg/sqcm pressure pipe of approved make
0478
586 (PVC) m
90 mm outer dia 2kg/sqcm pressure pipe of approved make (PVC)
0479
587 m
Sand cast iron soil waste double equal junction of required degree,
0493
588 75x75x75x75 mm m
589 0534 M S Square pippe 16 G Black pipe Kg
590 0702 100 mm asbestos cement pipes m
591 0703 100 mm dia 1 m long GI pipe m
592 0755 HDPE pipes-90 mm dia m
593 0782 RCC pipes NP3 1200 mm dia including collars m
594 0783 RCC pipes NP3 900 mm dia including collars m
595 0821 RCC pipes NP3 300 mm dia including collars m
596 0822 RCC pipes NP3 450 mm dia including collars m
597 0823 RCC pipes NP3 600 mm dia including collars m
598 0824 RCC pipes NP3 750 mm dia including collars m
599 0825 RCC pipes NP2 300 mm dia including collars m
600 0826 RCC pipes NP2 450 mm dia including collars m
601 0827 RCC pipes NP2 600 mm dia including collars m
602 0828 RCC pipes NP2 750 mm dia including collars m
603 0829 RCC pipes NP2 900 mm dia including collars m
604 0830 RCC pipes NP2 1200 mm dia including collars m
605 0831 RCC pipes NP4 900 mm dia including collars m
606 0832 RCC pipes NP4 1200 mm dia including collars m
607 565 RCC pipes NP2 150 mm dia including collars m
608 566 RCC pipes NP2 250 mm dia including collars m
609 0911 RCC pipes 200mm dia, 2.5m long for drainage m
610 0929 Plastic tubes 50cm dia, 1.2m high Nos.
611 565 RCC pipes NP 2, 150 mm dia including collar m
612 566 RCC pipes NP 2, 250 mm dia including collar m
613 568 RCC NP 4 100 mm dia including collars m
614 0001 100mm 'S' or 'P' trap Each
615 0023 Bevel lead mirror of superior glass of size 600x450mm Each
616 0024 Bib cock 15mm nominal bore-NP Each
617 0025 Bib cock 20mm nominal bore-NP Each
618 0026 Bib cock 25mm nominal bore-NP Each
619 0027 Bib cock 32mm nominal bore-NP Each
620 0028 Bib cock 40mm nominal bore-NP Each
621 0029 Bib cock 50mm nominal bore-NP Each
622 0034 black plastic seat and lid as specified Each
623 0040 Brass ball vlave with plastic float 15mm nominal bore Each
624 0041 Brass ball vlave with plastic float 20mm nominal bore Each
625 0042 Brass ball vlave with plastic float 25mm nominal bore Each
626 0043 Brass ferrule and C.1 Mouth cover 15mm nominal bore Each
627 0044 Brass ferrule and C.1 Mouth cover 20mm nominal bore Each
628 0045 Brass ferrule and C.1 Mouth cover 25mm nominal bore Each
629 0047 Brass shower rose C.P 100mm dia Each
630 0048 Brass shower rose C.P 150mm dia Each
631 0049 Brass stop cock-15mm Each
Brass union 15mm nominal bore with PVC connection pipe 300mm
0050
632 length Each Each
Brass union 15mm nominal bore with PVC connection pipe 450mm
0051
633 length Each
Brass union 20mm nominal bore with PVC connection pipe 300mm
0052
634 length Each
Brass union 20mm nominal bore with PVC connection pipe 450mm
0053
635 length Each
636 0067 C.I manhole cover with frame 610x455mm size (38 Kgs) Each
637 0068 C.I/M.S. brackets for flushing cistern Pair
638 0069 C.I Cover 500mm dia -50mmthick(16Kgs) Each
639 0070 C.P brass chain plug Each
640 0071 C.P brass chain with stainless steel plug Each
641 0072 C.P.brass pillar tap elbow operated Each
642 0073 C.P. brass screws 25mm with washers Each
643 0074 C.P.brass towel rail 600mm length 20mm dia Each
644 0075 C.P.brass towel rail 740mm length 20mm dia Each
645 0076 C.P.brass waste union 32mm of standard pattern Each
646 0077 C.P.brass waste union 40mm with fittings Each
647 0079 Cast iron foot rest Each
Circular shape mirror of size 450mm dia with plastic moulded
0105
648 frame Each
649 0114 Copper plated brass piller tap Each
650 0117 Gun metal non-return valve 100mm nominal bore horizontal type Each
651 0118 Gun metal non-return valve 100mm nominal bore verticall type Each
652 0119 Gun metal non-return valve 25mm nominal bore horizontal type Each
653 0120 Gun metal non-return valve 25mm nominal bore vertical type Each
654 0121 Gun metal non-return valve 32mm nominal bore horizontal type Each
655 0122 Gun metal non-return valve 32mm nominal bore vertical type Each
656 0123 Gun metal non-return valve 40mm nominal bore horizontal type Each
657 0124 Gun metal non-return valve 40mm nominal bore vertical type Each
658 0125 Gun metal non-return valve 50mm nominal bore horizontal type Each
659 0126 Gun metal non-return valve 50mm nominal bore vertical type Each
660 0127 Gun metal non-return valve 65mm nominal bore horizontal type Each
661 0128 Gun metal non-return valve 65mm nominal bore vertical type Each
662 0129 Gun metal non-return valve 80mm nominal bore horizontal type Each
663 0130 Gun metal non-return valve 80mm nominal bore vertical type Each
664 0139 Europian type water closet of specified make Each
665 0143 G.I 32mm dia telescopic flush pipes with fittings/specials Set
G.I.Flush pipe of standard size and C.P brass spreaders,brass
0144
666 unions and clamps 'including fittings Set
667 0145 G.I jam nut Each
668 0159 Gate valve 15mm nominal bore-gun metal Each
669 0160 Gate value 20mm nominal bore-gun metal Each
670 0161 Gate value 25mm nominal bore-gun metal Each
671 0162 Gate value 32mm nominal bore-gun metal Each
672 0163 Gate value 40mm nominal bore-gun metal Each
673 0164 Gate value 50mm nominal bore-gun metal Each
674 0165 Gate value 65mm nominal bore-gun metal Each
675 0166 Gate value 80mm nominal bore-gun metal Each
indian type water closet of size 580 mm of specified make with
0204
676 footrests Each
677 0273 Orissa pattern of size 575x425 mm with integal type foot rests Each

0274
678 Oval shape mirror of size 450x350 mm with plastic moulded frame Each
679 0275 P.V.C automatic flushing cistern 7.5 litres with fittings Each
680 0276 P.V.C automatic flushing cistern with fittings 10 litres Each
681 0277 P.V.C automatic flushing cistern with fittings 15 litres Each
P.V.C flushing cistern 10 litres low level with accessories 40mm
0278
682 flush pipe Each
683 0279 P.V.C pipes unplasticised 16mm m
684 0280 P.V.C pipes unplasticised 20mm m
685 0281 P.V.C pipes unplasticised 25mm m
686 0282 P.V.C pipes unplasticised 32mm m
687 0283 P.V.C automatic flushing cistern 5 litres with fittings Each
688 0284 P.V.C flushing cistern 10 litres low level with fittings Each
689 0411 stop cock Each
690 0434 water meter Each
691 0302 Polyethylene water storage tank of specified capacity and make L
Rectangulur shape mirror of size 1500x450mm with drain board of
0322
692 specific make Each
Stainless steel kitchen sink of size 400x470mm with drain board of
0396
693 specific make Each
Stainless steel kitchen sink of size 500x1000mm with drain board
0397
694 of specific make Each
Stainless steel kitchen sink of size 510x1575mm with drain board
0398
695 of specific make Each
696 0440 White glazed fire clay kitchen sink of size 600x450x250mm Each
697 0441 White glazed fire clay kitchen sink of size 750x450x250mm Each
698 0442 White glazed fire clay laboratory sink of size 450x300x150mm Each
699 0443 White glazed fire clay laboratory sink of size 600x450x200mm Each
White glazed/vitreous china clay 10 lts low level flushing cistern,
0446
700 with fittings and \brakets and 40mm white C.P flush pipe Set

0449
701 White vitreous china clay angle back wash basin size 500x400mm Each

0450
702 White vitreous china clay angle back wash basin size 600x480mm Each
White vitreous china clay flat back lipped front urinal basin of
0451
703 430x260x350mm size Each
White vitreous china clay flat back large urinal basin size
0453
704 580x380x350mm Each
705 0454 White vitreous china clay flat back wash basin size 450x330mm Each
706 0455 White vitreous china clay flat back wash basin size 550x400mm Each
707 0456 White vitreous china clay flat back wash basin size 630x450mm Each
708 0457 White vitreous china clay squatting plate Each
White vitreous china clay surgeon type wash basin size
0458
709 600x450x250mm Each
White vitreous china clay wall corner type, lipped front urinal basin
0460
710 of size '340x410x265mm Each
711 0487 C.P. brass tap with union Each
Rectangulur shape mirror of size 453x357mm with plastic moulded
0491
712 frame Each
713 0546 ceeramic tiles of size 30x30cms Sqm
714 2035 Colour Glazed tiles 30x60cms 6mm thick Each
715 2096 L. Bracket Nos.
716 0542 Galvanized L brackets Nos
717 2079 Granite sink 23cm thick Each
718 2098 Rubber Gaskete m
719 0083 Caustic soda Kgs
720 0092 Chiken mesh Sqm
721 0168 GI plaster mesh 0.35 mm thick 10 cms wide m
722 0251 Mosquito proof coupling 25 mm Each
723 0295 Plaster mesh 100mm wide m
724 0296 Plaster mesh 150mm wide m
725 0297 plaster mesh 200mm wide m
726 0318 Rabbit wire mesh Sqm
727 0548 Weld Mesh 75mmx25mm of 6G to 10G Sqm
728 0549 Weld Mesh 75x50mm of 6G to 10G Sqm
729 0729 Copper plate 12 m long x 250 mm wide Kgs
Wire create size(1.8x1.8mx0.9m)=2.916(4mm dia 2GI wire in 15
0796
730 cms x 15 cms mesh) Kgs
731 0797 Wire mesh 50 mm x 50 mm Sqm
732 0816 Form work for kerb stone/KM stone Sqm
733 0104 Cinder ballast cum
734 0093 Chlorophriphos emulstiable concentrate L
735 0065 Burnt lime/shell lime q
736 0141 Fly ash cum
737 0142 Fuel (firewood) q
738 0210 Kerosene oil L
739 0215 Lime cum
740 0216 Lime surkhi mortar 1:2 cum
741 0263 Mud mortar cum
742 0267 Nitric Acid L
743 0299 Plaster of Paris Kgs
744 0394 Spirit L
745 0412 Surkhi cum
746 0436 Water proofing compound Kgs
747 0483 Diesel L
748 0709 Admixture/Super Plasticizer L
749 0715 Bentonite Tonne
750 0741 Epoxy for mortar Kgs
751 0742 Epoxy for tack coat Kgs
752 0743 Epoxy material for fixing Kgs
753 0760 Joint filler (0.01 cm wide and 0.12mm wide) Sqm
754 0761 Joint sealing com 25 mm deep Kgs
755 0811 Chloroperene C.C.
756 0812 Natural Rubber C.C.
757 0813 Neoprene Kgs
758 0818 Water KL
759 0268 Nortlight adjustable ridges of 1.22m Pair
760 0270 Nylon rollers Each
761 0315 Putty for filling holes Kgs
762 0319 Rawl Plug 40 to 50mm Each
763 0317 PVC Beading m
Roofing felt type-2 grade-1 fibre based self finish and bitumen
0328
764 based Sqm
765 0329 Rubber heading for shutturs beading m
766 0392 Spun yarn Kgs
767 0413 Suspension shaft m
768 0516 Plastic sheet Sqm
769 0527 Steel wool Pack
770 0535 Glazing seal m
771 0536 Weather Seal Nos
772 0539 Specer tape Sqm
773 0704 20mm thick compressible fiber band 12 m long x 25 cm deep Sqm
774 0705 20 mm thick filler 12m long x 25 cm deep Sqm
775 0737 Deviator Plates Tonne
Elastomeric slab with MS plates inserted inside polysulphine
0740
776 compound filling Space around Bolts and nuts C.C.
777 0774 Nipples Each
778 0788 Sheething duct ID m
779 0809 PTFE Nodules Sq.cm
780 0810 PTFE Nodules cm
781 0331 S.F.R.C. Cover and frame 560 mm (ID) heavy duty Each
782 0850 Fine Grass Kgs.
783 0851 Hedge plant Each
784 0852 Flowring plants Each
785 0853 Shrubs Each
786 0854 Sapiling 2m high 25mm dia Each
787 0855 Neem cake q
788 0856 Empty bitumen drum Each
789 0857 Rivets Each
790 0858 Steel wire 3mm dia Kgs
791 0859 Sapling 1 to 1.5m high 2cm dia stem Nos.
792 0861 Traffic cones with 150mm reflective sleeve Nos.
793 0871 Flag of red color cloth 600x600mm Each
794 0900 Supply of quarried stone 150-200 size cum
795 0901 Stone boulder of size 150mm and below cum
Precast cement concrete tiles Tiles size 300x300mm and 25mm
0910
796 thick Nos.
797 1104 Jute Rope m
798 0925 cold miling machine at 20cum per hour cum
799 0927 Scrap types of size 900x20 Nos.
800 0928 20mm steel wire rope Kgs.
801 0933 Geotextile filter frabic Sqm.
802 0934 perforated geosynthetic pipe 150mm dia m
803 0935 Paving fabric Sqm.
804 0936 Geogrids Sqm.
805 0937 Connectors/staples Each
806 0938 Polymer braids m
807 0945 Hot applied thermoplatic compound L
808 0946 Reflectorising glass beads Kgs.
Cost of approved type of delineators from ISI certified firm as per
0947
809 the standard drawing given in IRC:79 Each
810 0948 Barbed wire 335 metre length at 9.38 kg per 100 metre Kgs.
811 0960 Sand bags(cost of sand in empty cement bag) No.
812 0964 Admixture Kgs.
813 0966 M 35 grade RCC corbel provided for supporting of euipment cum
814 0971 NUTS AND Bolts Kgs.
Elastomeric slab seal expansion joint assembly manufactured by
0980 using chloroprene, elastomer for elastomeric slab unit conforming
to clause 9150.1 of IRC:83 (part II) conforming to clause 2600.6 of
815 Morth specifications. m
Preformed continuous chloroprene elastoemer or closed cell foam
0982 sealing sealing element with high mtear strength vulcanised in a
single operation for the full length of a joint ot ensure water
816 tightness. m

0983 Supply of complete assembly of strip seal expansion joint


comprising of edge beams, anchorage, strip seal element and
817 complete accessories as per approved specifications and drawings m

Supply of a modular strip/box seal joint assembly comprising of


edge beams, central beam, 2 modules chloroprene seal,
0984 anchorage elements, support and control system, all steel sections
protected against corrision and installed by the manufacturer or his
818 authorised representative. m

Supply of a modular/box/box seal joint assembly containing 3


modules/cells and comprising of edge beams, two central beams,
0985 chloroprene seal, anchorage elements, support and control
system, all steel sections protected against corrosion and installed
819 by the manufacturer or his authorised representative. m
820 0986 LDO L
821 0987 Trailor 30 Tonne capacity hr
822 0990 Farmyard manure cum
823 0991 Seeds Kgs.
824 0992 Jute netting Sqm
825 0994 Doob grass Kgs.
826 0997 Accelerator compound for guniting Kgs.
827 0998 Wire mess 50mm x 50mm size of 3mm wire Kgs.
828 1101 Sodium vapour lamp - 250 watt Each
Pre - packed ploymer concrete based on epoxy system complete
1502
829 with curing compound, intiator and promoter Kgs.
830 1505 Quick setting compound Kgs.
831 1507 Acrylic polymer bonding coat L
Pre-packed cement based ploymer mortar of strength 45 Mpa at
1508
832 28 days Kgs.
Epoxy resin with pot life not less than 60-90 minutes and satisfying
1509
833 testing as per clause 2800.3.9 Kgs.
834 1514 bearing Neoprene No.
Separation membrane of impermeable plastic sheeting 125 micron
1521
835 thick Sq.cm
836 1522 Pre-moulded joint filler, 25mm thick for expansion joint Sq.cm
837 1523 Joint sealant Kgs.
838 1524 Sealant Primar Kgs.
839 1525 Curing compound L
Super plasticizer admixture IS marked as per 9-103-1999 at 0.5%
1526
840 by wt. of cement Kgs.
841 1552 Collar for AC pipe (average) Nos,
Elastomeric bearing assembly consting of 7 layers of elastomer
1555 bonded to 6 nos. reinforcing steel laminates by the process of
vulcanisation, complete with all components as per drawings and
842 technical specifications. Nos.
Pot type bearing consisting of a metal piston supported by a
disc,PTFE pads providing sliding surfaces against stainless steel
1556 mating together with cast steel assemblies/ fabricated structural
steel assemblies duly painted with all components as per clause
843 2006 and complete as per drawing and technical specifications. Nos.
844 547 Expanded metal 12.5 mm to 25 mm -14 G Sqm
845 548 Weld Mesh 75mmx25mm of 6G to 10G Sqm
846 549 Weldmesh 75 x 50mm of 6g x 10g Sqm
847 552 Pesticide L
848 553 Granite slabs 7.5 cm to 8 cm thick sqm.
849 557 Guard stones 700 mm X 200 mm X 200 mm Nos.
850 559 15 mm bolt Nos.
851 560 60 x 60 x10 Guage sq.plate washer Kgs.
852 570 Sealant Kgs.
853 563 PVC Storage Tank L
854 564 12x12 guage GI wire 100 mtr at Ts. 8.00/m m
855 574 Steel Helmet and Cushion block Kgs.
Vibrating pile driving hammer complete with hour unit and
575
856 accessaries hr
857 0930 Geonets Sqm
858 0931 Geomembrane Sqm
859 0932 Geotextile Sqm
860 2001 Carbon electrodes cm
861 2004 Screws 3.5" Nos.
862 2005 Screws 1.75" Nos.
Latch, Pivot, Locking arrangements, SS door rails etc for glass
863 2013 doors Set
864 2023 Cast iron ornamental design Nos
865 2024 Cast iron arrows No
866 2025 Expansion bolt No
867 2052 Coconut Broom stick No.
868 2053 Bombay broom stick No.
869 2054 Squeezer / wiper / rubber brushes No.
870 2055 Coir brushes No.
871 2056 Bamboo baskets No.
872 2057 Plastic buckets 20 L capacity No.
873 2058 Trollies No.
874 2064 Cobble stone 65mm thick Sqm
875 2065 Cobble stone 80mm thick Sqm
876 2072 Welding rods Nos
877 2037 Ball beaing hinges heavy duty Nos.
878 2041 G.I. Coated expansion bolts Nos.
879 2048 Ball Joints Kgs
880 2049 Design-Trowel Nos.
881 2059 Hose pipe 30m length No.
882 2061 Plastic Mug Each
883 2063 Bleaching Powder Kgs
884 2066 Bronze multiwall polycorbonate G.E. make Kgs
885 2070 Sealent taps Joint
886 2080 Mop stick - alluminium No.
887 2082 Disposable garbage bags size 0.9m x 1.5m Each
888 2087 RBI Grade 81 Tonne
889 2088 Safe N Easy/Equivalent Bio-degradable L
890 2093 Polymeric expansion joints filler - 12mm thick Sqm
891 2094 Polymeric expansion joints filler - 18mm thick Sqm
892 2095 Polymeric expansion joints filler - 22mm thick Sqm
893 2102 Crystallisation liquid Kgs
894 2103 Isoproof Kgs
895 2104 Acrylic Kgs
896 2105 FCM Kgs
897 2106 Non woven geo textile Kgs
898 2107 Polysulphide /acrylic sealant Kgs
899 2112 No.
900 9001 Gulty Trap No.
901 2097 5mm Semi finished PVC Sheet Sqm
902 3001 PVC Pipes 10KG/Sqm 90mm outerdia M
903 3002 PVC Pipes 10KG/Sqcm 110mm outerdia M
904 3003 PVC Pipes 10KG/Sqcm 140mm outerdia M
905 3004 PVC Pipes 10KG/Sqcm 160mm outerdia M
906 3005 PVC Pipes 10KG/Sqcm 180mm outerdia M
907 3006 PVC Pipes 10KG/Sqcm 200mm outerdia M
908 3007 PVC Pipes 10KG/Sqcm 225mm outerdia M
909 3008 PVC Pipes 10KG/Sqcm 250mm outerdia M
910 3009 PVC Pipes 10KG/Sqcm 280mm outerdia M
911 3010 PVC Pipes 10KG/Sqcm 315mm outerdia M
912 3022 Water less urinal of size 328x319x598mm Each
913 2203 Galvanised Steel 105 x 50 mm M
914 2204 Galvanised Steel 20 x 47 mm M
915 2205 Galvanised Steel 58 x 36 mm M
916 2206 Galvanised Steel 22 x 20 (FW 66 mm) M
917 2207 Galvanised "C" Section 12 x 3 M
918 2208 Float Glass 5 mm Thick Sqm
919 2212 M.S. Grill Powder Coated 100 mm Pitch Sqm
920 221 Galvanised "C" Section 18 x 7 (FW 33 mm) M
921 2209 Galvanised Steel20 x 24 (FW 33 mm) M
922 2213 Galvanised Steel 90 x 50 mm M
923 2214 TMT Bars Fe 500 M
924 2215 TMT Bars Fe 550 M
925 2216 Maranthi Wood cum
926 2217 Galvanised Steel 70 x 55 mm M
927 2218 Galvanised Flymesh Section 20 x 40 mm M
928 2219 Galvanised Steel Section 48 x 25 mm M
929 2220 Galvanised Steel (Glass Beading ) 12 x 12 mm M
930 2221 Mesh (SS 304 Grade) Sqm
931 2222 Galvanised Steel 72 x 55 mm M
932 2223 Galvanised Steel Section 48 x 50 mm M
933 2224 Galvanised Steel Section 46 x 52 mm M
934 2225 Galvanised Steel Section 46 x 46 mm M
935 2226 Galvanised Beading Section 18 x 25 mm M
936 2227 Fly ash bricks of size 60 x 20 x 15 cm 100 No.
937 2228 White cement based putty Kgs
Vitrifed tiles - 10 mm thick double charged, nano technology size
Sqm
938 800mmx800mm
Vitrifed tiles - 10 mm thick double charged, nano technology size
Sqm
939 1200mmx600mm
Light weight Concrete (Autoclaved aereated cellular)Blocks of size
Each
940 3023 60 x 20 x 15 cm
941 Solid blocks concrete 40 x 15 x 20 cms 100 No.
Light weight Concrete (Autoclaved aereated cellular)Blocks of size
Each
942 3024 60 x 20 x 10 cm
Light weight Concrete (Autoclaved aereated cellular)Blocks of size
Each
943 3025 60 x 20 x 20 cm
944 3027 Polymer modified stucco mortar Kg
945 Sal wood (Red) cum
946 2229 Precast Hallow blocks (40x20x20 cm) grade 50 100 No.
947 2280 Solid blocks concrete (40 x 15 x 20 cms) grade 35 100 No.
948 580 Raw-silk granite 20mm thick Sqm
949 Table top 25mm thick PLPB with edge banding Sqm
950 75mm thick MS CRCA partition with PLPB tiles Sqm
951 25 mm thick PLPB separator with edge handing Sqm
952 L clamps No.
953 Nut and bolt No.
954 Separator and D-Brackets No.
955 Cantilever Brackets No.
956 End table hode on Bracket No.
957 Corner Hook on Bracket No.
958 25mm thich front modesty Sqm
959 25mm thich legs sqm
960 Minifix housing No.
961 Wooden dowels M8x40 No.
962 M6 screw leg No.
963 M6 Insert No.
964 64 mm dia grommet cap No.
965 50mm thick glass wool Sqm
966 Wood screws No.
967 Ahro tape/press putty Bundle
968 Lipping 1”x ¼ “ Rmt
969 Etching of glass Sqm
970 Patch fittings No.
971 Pivot No.
972 Floor machine No.
973 Locking system No.
974 SS Door rails Set
975 25mm treated commercial black board Sqm
976 Teak wood balls No.
977 19mm block board vinyl bonded w/p 7’x3’ Sqm
Rate in Rs.
180.00
22.00
62.00
148.00
18.00
170.00
205.00
210.00
600.00
600.00
600.00
610.00
550.00
700.00
700.00
1325.00
1200.00
3800.00
4450.00
2800.00
3100.00
4700.00
4000.00
2100.00
47.00
35.00
28.00
675.00
750.00
825.00
825.00
975.00
1050.00
950.00
950.00
750.00
750.00
975.00
600.00
750.00
825.00
700.00
975.00
925.00
975.00
750.00
1100.00
950.00
950.00
750.00
750.00
6000.00
350.00
1700.00
120.00
1700.00
160.00
160.00
1700.00
400.00
22.00
600.00
400.00
1600.00
400.00
11.00
500.00
22.00
250.00
11.00
400.00
300.00
600.00
300.00
600.00
132.00
58.00
38.00
39.00
75.00
280.00
172.00
3200.00
195.00
3600.00
230.00
3775.00

52900.00

3775.00
345.00
165.00
190.00
201.00
40866.00
44907.00
41877.00
45918.00
40866.00
40866.00
51671.00
73810.00
71927.00
40096.00
85.00
1.00
15.00
30.00
40866.00
73810.00
8.00
375.00
200.00
110.00
582.00
672.00

582.00
875.00
1000.00
1700.00
600.00
450.00
120.00
138.00
600.00
720.00
1080.00
1050.00
780.00
745.00
1004.00
873.00
345.00
670.00
1800.00
620.00
340.00
250.00
300.00
275.00
350.00
400.00
458.00
286.00
225.00
225.00
900.00
600.00
20.00
858.00
725.00
1200.00
550.00
343.00
175.00
612.00
544.00
1500.00
435.00
91.00
1.50
1.70
1400.00
1800.00
973.00
2100.00
1200.00
1400.00
1030.00
207.00
286.00
1500.00
2500.00
1100.00
950.00
2100.00
7.00
5.50
40.00
250.00
4.00
13.00
100.00
250.00
6.50
6.70
500.00
1000.00
485.00
450.00
350.00
125.00
270.00
400.00
4600.00
4800.00
4900.00
5100.00
5300.00
200.00
45.00
45.00
45.00
650.00
15.50
45.00
5200.00
5200.00
41.00
4100.00
45.00
45.00
48.00
41.00
48.00
48.00
45.00
45.00
50.00
45.00
45.00
280.00
60500.00
60.00
51.00
83.00
58.00
230.00
52000.00
5200.00
44500.00
50000.00
4100.00
41.00
43.00
50000.00
50000.00
50000.00
89.00
89.00
50.00
288.00
264.00
90.00
40.00
45.00
48.00
45.00
48.00
111.00
45.00
45.00
55.00
45.00
45.00
45000.00
45.00
45.00
45.00
45.00
90.00
48.00

48.00
48.00

48.00

166.00
48.00
7700.00

12690.00
0.55
4400.00
57200.00
54637.00
54637.00
48.00
78490.00

78490.00

45.00
50.00
58.00
211.00
54.00
55000.00
3349.00
4950.00
43.00
60.00
60.00
52.00
59.00
59.00
127.00
52.00
52.00
48.00
48.00
88.00
60.00
48.00
294.00
294.00
48.00
48.00
55.00
281.00
264.00
52000.00
45.00

45.00
45.00
46.00
176.00
45.00
15.00
70000.00
15.00
21.00
70000.00
70000.00
70000.00
76000.00
76000.00
71000.00
71000.00
34000.00
34000.00
34000.00
34000.00
34000.00
58000.00
58000.00
58000.00
58000.00
56000.00
12.00
58000.00
58000.00
58000.00
65.00
495.00
420.00
12500.00
46000.00
46000.00
24000.00
140000.00
25.00
65.00
140000.00
5.00
160000.00
160.00
160000.00
160000.00
160000.00
20.00
50.00
35.00
18000.00
172.00
3.00
43.00
55.00
43.00
34000.00
10.00
250.00
25.00
46000.00
2.00
25.00
650.00
920.00
517.00
200.00
500.00
275.00
325.00
900.00
2300.00
2700.00
1350.00
68.00
58.00
38.00
47.00
2.10
100.00
127.00
53.00
1319.00
401.00
61.00
56.00
1002.00
37.00
38.00
633.00
44.00
47.00
26.00
33.00
38.00
13.00
63.00
62.00
54.00
51.00
52.00
3.00
135.00
20.00
116.00
550.00
4.00
38.00
17.00
40.00
74.00
84.00
89000.00
120.00
325.00
235.00
100.00
4.00
17.00
13.00
33.00
897.00
198.00
99.00
132.00
110.00
202.00
68.00
66.00
250.00
99.00
180.00
215.00
130.00
110.00
140.00
230.00
85.00
85.00
88.00
165.00
450.00
130.00
181.00
75.00
250.00
66.00
75.00
330.00
110.00
22.00
198.00
220.00
210.00
220.00
153.00
220.00
60.00
275.00
77.00
60.00
175.00
220.00
75.00
75.00
75.00
105.00
198.00
220.00
210.00
220.00
153.00
330.00
660.00
206.00
30.00
325.00
40.00
120.00
23.00
44.00
194.00
70.00
140.00
338.00
275.00
143.00
172.00
1328.00
1088.00
286.00
320.00
338.00
149.00
802.00
1202.00
109.00
137.00
197.00
223.00
279.00
321.00
480.00
611.00
100.00
350.00
14.00
183.00
185.00
143.00
120.00
137.00
155.00
172.00
235.00
44.00
63.00
115.00
143.00
172.00
378.00

286.00

309.00
802.00
378.00
779.00
229.00
326.00
555.00
600.00
836.00

342.00

550.00

721.00

342.00

916.00

802.00
916.00

660.00

492.00

607.00

893.00

555.00

458.00

916.00

922.00

344.00

802.00

504.00

573.00

573.00

784.00

441.00

573.00

802.00

504.00

401.00

395.00
332.00

653.00

687.00

452.00

573.00

567.00
447.00
498.00
40.00
60.00
100.00
140.00
150.00
160.00
175.00
180.00
190.00
225.00
120.00
172.00

177.00

132.00

527.00
57.00
50.00
824.00
120.00
7250.00
4650.00
1100.00
2050.00
2600.00
2850.00
800.00
1100.00
1700.00
2100.00
2750.00
4750.00
5650.00
9100.00
300.00
400.00
250.00
36.00
300.00
400.00
8350.00
60.00
850.00
170.00
189.00
212.00
287.00
287.00
343.00
286.00
280.00
300.00
450.00
100.00
150.00
180.00
555.00
600.00
200.00
150.00

175.00

175.00

200.00
2200.00
100.00
1030.00
125.00
215.00
460.00
5.00
450.00
500.00
120.00
183.00
131.00
515.00
230.00
2290.00
2347.00
515.00
415.00
665.00
665.00
859.00
802.00
1202.00
1145.00
1660.00
1431.00
1947.00
1740.00
1050.00
350.00
500.00
23.00
250.00
316.00
460.00
750.00
1000.00
1600.00
2050.00
2462.00
687.00
1400.00
580.00
687.00
744.00
801.00
650.00
44.00
46.00
56.00
65.00
500.00
600.00
125.00
744.00
6.20

1144.00

4500.00

6900.00

13600.00
1400.00
1660.00
900.00
1145.00

1832.00

773.00

1000.00

700.00

2060.00
600.00
780.00
900.00
1000.00

1000.00

630.00
285.00
802.00
435.00
85.00
29.00
40.00
10305.00
17.00
46.00
19.00
35.00
29.00
23.00
29.00
35.00
63.00
280.00
213.00
460.00
172.00
322.00
20.00
287.00
200.00
450.00
20.00
550.00
45.00
4000.00
550.00
230.00
80.00
21.00
46.00
345.00
46.00
62.00
207.00
4800.00
172.00
345.00
207.00
230.00
168.00
1.00
1.00
230.00
40.00
160.00
6.00
80.00
2.50
12.00
110.00
35.00
40.00
950.00
6.00
25.00
350.00
200.00
40.00
410.00
430.00
46000.00
0.50
10.00
15.00
8.00
0.10
900.00
7.00
3.00
2.50
2.00
10.00
900.00
100.00
3.00
45.00
8.00
400.00
20.00
420.00
402.00
26.00
5.50
20.00
218.00
40.00
76.00
250.00
20.00
310.00
6.00
32.00
110.00
55.00
260.00
35.00
50.00
65.00
4200.00
52.00

12660.00
13715.00

12325.00

5697.00

6857.00

42.00
1000.00
110.00
120.00
14.00
34.00
21.00
42.00
1319.00
10.00
158.00
400.00
200.00

575.00
2089.00
4.00
7.00
180.00
150.00
220.00
70.00
69.00

10076.00
80500.00

280.00
230.00
213.00
280.00
100.00
87.00
9.00
39.00
115.00
5.00
12.00
60.00
150.00
65.00
65.00
65.00
0.50
4.00
2.00
8000.00
80.00
85.00
29.00
40.00
55.00
90.00
35.00
105.00
120.00
1600.00
340.00
470.00
5.00
287.00
35.00
180.00
57.00
830.00
30.00
80.00
1200.00
6.00
120.00
11.50
32840.00
499.00
540.00
781.00
1081.00
150.00
300.00
200.00
70.00
85.00
310.00
3.00
30.00
510.00
350.00
510.00
840.00
1080.00
1400.00
1700.00
2100.00
2600.00
3300.00
4200.00
24500.00
210.00
105.00
160.00
45.00
20.00
470.00
700.00
22.00
47.00
200.00
44500.00
45000.00
36200.00
193.00
130.00
175.00
1.00
350.00
195.00
180.00
175.00
165.00
62.00
600.00
26.00

1000.00

2000.00

100.00
3500.00

60.00

120.00
23.00
42000.00
4300.00
4100.00
1300.00
1900.00
3000.00
1900.00
5.00
4.00
30.00
95.00
35.00
35.00
1800.00
2150.00
4.00
1.50
6.00
5.00
10.00
165.00
4.00
298.00
24.30
1350.00
1400.00
350.00
6500.00
1000.00
700.00
1900.00
200.00
1150.00
Notes Provided in SR 2014 - 15

Note - 1

Note - 2

Note - 3

Note 1

Note 2

Note 1

Note 1

Note 2

Note 1

Note 1

Note 1

Note 1
Note 1

Note 2

Note3

Note4

Note

Note 1.

Note 2.

Note 3.

Note 4.

Note 5.

Note

Note.1

Note.2
Note.3
Note.4

Note 1

Note 2

Note 3

Note 4

Note 5

Note 1

Note 2

Note 3

Note 4

Note 5
Note

Class of
Occupancy

Group A

Group B

Group C
Group D

Group E

Group F

Group G
Group H

Group J

NOTES : 1 LH - Low Hazard, 2 MH - Medium Hazard, 3 HH - High Hazard, 4 SH: Special Hazard.

B-2 RECOMMENDED SCALE OF EQUIPMENT TO BE INSTALLED


B-2.1 Class A
LH

MH
HH

Special
Hazard
LH

MH
HH

LH
MH
HH

HH
Notes Provided in SR 2014 - 15
1.0 - MORTAR
…………………………………………………………..
2.0 - EARTH FOR BUILDINGS
Adopt item 2.24 for excavation in all types of soils for lowering & levelling the ground for building works
by mechanical means
KSRB 2.2 Excavation for foundation of buildings, water supply sanitary lines, electrical conduits either in
pits or in trenches where excavation width is above 600 mm below 1.5 mtrs. depth add 25% extra and for
width upto 600 mm add 50% extra for respective rates due to restricted conditions.
KSRB 2.2 Extra for excavation under water conditions and/or foul conditions including bailing/pumping
out, removing slush add 20% of the rate of the respective rate on account of slow progress of work under
these conditions.
3.0 - ANTI TERMITE TREATMENT
…………………………………………………………..
4.0 - CEMENT CONCRETE
Lift charges: An additional rate of Rs.50.00/cum per floor may be added for every additional floor for
items under Sl.No. 4.1 to 4.13 and Rs.5.00/sqm per floor may be added for every additional floor for
items under Sl.No. 4.19, 4.20, 4.27, 4.55, 4.56, 4.57, 4.58.1, 4.58.2, 4.28 to 4.42. For 4.43.1 to 4.44.4
an additional rate of Rs. 5.0/floor may be added.
Centering height of 3.5 meters is considered for item No. 4.28, 4.30 to 4.44.4. An additional rate Rs. 20
shall be added for every additional meter or part thereof for the above limits.
5.0 - STONE WORK
Additional rate of Rs. 30.00/Sqm. for item no. 5.24, 5.25, 5.26, 5.27, 5.28, 5.34 for every additional floor.
6.0 - BRICK WORK

Lift charges: The above rates are applicable for Ground floor only. An additional rate of Rs. 50.00/cum
and Rs. 5/sqm per floor may be added for every additional floor above or below the ground floor.
Add 10% extra for gable portion.
7.0 -STEEL AND ALUMINIUM WORK
Lift charges: The above rates are applicable for Ground and basement floors only. Add an additional rate of Rs.
5.00/sqm per floor above or below.
8.0 - ROOFING
…………………………………………………………..
9.0 - WOOD WORK
Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.3.00/sqm per floor may be added for every additional floor for items vide Sl.No.9.6 to 9.9, 9.14 to
9.99, 9.101, 9.102 and 9.106
10.0 WATER PROOFING
…………………………………………………………..
11.0 DRAINAGE WORK
…………………………………………………………..
12.0 SANITARY WORK
…………………………………………………………..
13.0 WATER SUPPLY WORK
Add 15% extra for internal water supply items.
14.0 FLOORING
Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.1.50/sqm per floor may be added for every additional floor for items vide Sl.No.14.1 to 14.72.
15.0 FINISHING WORK
Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.5.00/sqm per floor for plastering works only may be added for every additional floor.

Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.3.00/sqm per floor for painting works of exterior walls only may be added for every additional floor.

Scaffolding charges : An additional rate of Rs. 10.00/sqm per floor for external plastering works only may
be added for every additional floor.
Scaffolding charges : An additional rate of Rs. 3.00/sqm for painting works of exterior walls only maybe
added for every additional floor.
16.0 REPAIRS TO BUILDINGS
…………………………………………………………..
17.0 ROADS and BRIDGES Carriage of Materials
…………………………………………………………..
18.0 SITE CLEARANCE and DISMANTLING
…………………………………………………………..
19.0 EARTH WORK, EROSION CONTROL and DRAINAGE
…………………………………………………………..
20. 0 SUB BASES, BASES (Non Bituminous) and SHOULDERS
KSRRB-400-2,4
This analysis provides for median and island with earthen top. In
case the surface is required to be turfed or planted with shrubs,
the same is required to be provided separately.
KSRRB M400-20. Construction of Shoulders
A. Earthen Shoulders. The rate as applicable for sub-grade
construction may be adopted.
B. Hard Shoulders. Rate as applicable for sub-base and or base
may be adopted as per approved design.
C. Paved Shoulders. The rate may be adopted as applicable
for different layers of pavement depending upon approved
design of paved shoulders.
Cost of flyash has not been considered as same will be availablefree of cost. Only
carriage of flyash has been provided.
Lime + Flyash has been taken as 20% of total mass and ratio of
lime and flyash as 1:4 for estimating purposes. Total quantities
will be as per approved design.
Ground granulated blast furnace slog/slag sand may be used for
item No. 20.1, 20.2, 20.3, 20.4, 20.5, 20.6, instead of river sand, grit
and 6mm below aggregate or in combinations.
21.0 BASE and SURFACE COURSES (Bituminous)
NOTE : KSRRB 500-11, 13, 16, 17, 18, 19,
Labour for traffic control, watch and ward and other miscellaneous
duties at site including sundries have been included in administrative
overheads of the contactor.
Where tack coat is required to be provided before laying mastic
asphalt, the same is required to be measured and paid separately.
affinity for bitumen as a condition for the approval of that source the
bitumen shall be treated with approved anti stripping agent as per the
test and determination of bituminous binder content and gradation
of aggregates in the mix and (c) determination of density and
22.0 CONCRETE PAVEMENT
…………………………………………………………..
23.0 GEOSYTHETIC and REINFORCED EARTH
…………………………………………………………..
24.0 TRAFFIC SIGNS, MARKINGS
…………………………………………………………..
25.0 BRIDGES - PILE FOUNDATION
…………………………………………………………..
26.0 BRIDGES - WELL FOUNDATIONS
KSRRB M 1200-13.3,14.3, 15.3, 16.3, 17.3, 18.3, 19.3, 20.3, 21.3,22.3, 23.3, 24.3, 25.3, 26.3, 27.3 and
28.3 beyond 10m upto 20m - Add 5% for every additional meter depth of sinking over the rate for
sinking of previous meter (for - 10m to 11m/ 11m to 12m/ 12m to 13m/ 13m to 14m/ 14m to 15m/ 15m to
16m/ 16m to 17m/ 17m to 18m/ 18m to 19m/ 19m to 20m)
KSRRB M 1200-13.4,14.4, 15.4, 16.4, 17.4, 18.4, 19.4, 20.3, 21.4,22.4, 23.4, 24.4, 25.4, 26.4, 27.4 and
28.4 beyond 20m upto 30m - Add 7.5% for every additional meters of depth of sinking over the rate of
sinking for the pervious meter (for - 20m to 21m/ 21m to 22m/ 22m to 23m/ 23m to 24m/ 24m to 25m/
25m to 26m/ 26m to 27m/ 27m to 28m/ 28m to 29m/ 29m to 30m)

KSRRB M 1200-13.4,14.4, 15.4, 16.4, 17.4, 18.4, 19.4, 20.3, 21.4,22.4, 23.4, 24.4, 25.4, 26.4, 27.4 and
28.4 beyond 20m upto 30m - Add 20%of cost for Kentledge including supports, loading arrangement and
labour where cost is 80% of finished rate of previous meter (for - 20m to 21m/ 21m to 22m/ 22m to 23m/
23m to 24m/ 24m to 25m/ 25m to 26m/ 26m to 27m/ 27m to 28m/ 28m to 29m/ 29m to 30m)

KSRRB M 1200-13.5,14.5, 15.5, 16.5, 17.5, 18.5, 19.5, 20.5, 21.5, 22.5, 23.5, 24.5, 25.5, 26.5, 27.5 and
28.5 beyond 30m upto 40m. - Add 10% for every additional meters of depth of sinking over the rate of
sinking for the pervious meter (for - 30m to 31m/ 31m to 32m/ 32m to 33m/ 33m to 34m/ 34m to 35m/
35m to 36m/ 36m to 37m/ 37m to 38m/ 38m to 39m/ 39m to 40m)

KSRRB M 1200-13.5,14.5, 15.5, 16.5, 17.5, 18.5, 19.5, 20.5, 21.5, 22.5, 23.5, 24.5, 25.5, 26.5, 27.5 and
28.5 beyond 30m upto 40m. - Add 20% of cost for Kentledge including supports, loading ar- rangements
and labour where cost is 80% of finished rate of previous meter.(for - 30m to 31m/ 31m to 32m/ 32m to
33m/ 33m to 34m/ 34m to 35m/ 35m to 36m/ 36m to 37m/ 37m to 38m/ 38m to 39m/ 39m to 40m)

27.0 BRIDGES - OPEN FOUNDATIONS


KSRRB M2100-1.1, KSRRB M2100-1.2, KSRRB M2100-1.3, KSRRB M2100-2.1, KSRRB M2100-2.2,
KSRRB M2100-2.3, KSRRB M2100-3.1, 3.2, 4.1, 4.2 Add 10% extra for dewatering charges and
specification is to be modified accordingly.
KSRRB M2100-5.1 : Add 30% extra for dewatering charges and specification is to be modified
accordingly.
KSRRB M2100-5.2: Add 20% extra for dewatering charges and specification is to be modified
accordingly.
Add 15% extra for shoring and shuttering for items KSRRB M2100-5.1 specification is to be modified
accordingly
Add 10% extra for shoring and shuttering for items KSRRB M2100-5.2 specification is to be modified
accordingly.
28.0 BRIDGES - SUB STRUCTURE
…………………………………………………………..
29.0 BRIDGES - CONCRETE SUPER STRUCTURE
…………………………………………………………..
30.0 BRIDGES -RIVER TRAINING and PROTECTION WORKS
…………………………………………………………..
31.0 BRIDGES - EXPANSION JOINTS
…………………………………………………………..
32.0 BRIDGES -WEARING COAT and APPURTENANCES
…………………………………………………………..
33.0 BRIDGES - REPAIRS and REHABILITATION
…………………………………………………………..
34.0 PIPE CULVERTS
…………………………………………………………..
35.0 MAINTENANCE OF ROADS
…………………………………………………………..
36.0 REINFORCED EARTH STRUCTURE
…………………………………………………………..
37.0 OTHER ITEMS
…………………………………………………………..
38.0 INNOVATIVE ITEMS
…………………………………………………………..
39.0 FURNISHING WORKS
The rate for the items 39.14.1, 39.14.2, 39.15.1, 39.15.2, 39.16.1,
39.16.2, 39.16.3, 39.16.4, 39.16.5 & 39.16.6 are for the complete unit
as per the drawing appended.
40.0 FIRE FIGHTING WORKS
…………………………………………………………..

ANNEX B
(Clause 5.3, IS2190:2010)
RECOMMENDATIONS FOR INSTALLATION OF FIRE EXTINGUISHERS

B-1 occupancies classified according to IS 1641 are given together with nature of fire hazard and type of
fire risk along with typical
examples. The classifications, groupings etc., given in this Annex are only for general guidance for
installation of fire extinguishers and not
for other purposes.

Type of
Occupancy

Residential
buildings

Educational
buildings

Institutional
buildings
Assembly
buildings D-1

D-2

D-3

D-3

D-4 & D-5


Business
buildings E-1
E-2
E-3

Mercantile
buildings
Industrial
buildings
Storage
buildings

hazardous

NOTES : 1 LH - Low Hazard, 2 MH - Medium Hazard, 3 HH - High Hazard, 4 SH: Special Hazard.

B-2 RECOMMENDED SCALE OF EQUIPMENT TO BE INSTALLED


Occupancy

Occupancy
Occupancy

B-2.2 Class B
Occupancy

Occupancy
Occupancy

B-2.3 Class C

Occupancy
Occupancy
Occupancy
B-2.4 Class D

Occupancy
NOTES -
1. The recommendations are minimum for a specific area.Incase, the area is more than specified, high
capacity extinguishers may be
used based on these minimum requirements,that is proportionately higher capacity can be used.
2. In case of dry powder /Co2/clean agent types, equivalent lower capacities may also be used.
3. The halons shall be restricted for essential use only.
4. On implementation of IS 15683, 6 kg and 9 kg dry powder extinguishers shall be replaced by 5 kg or
10 kg dry powder extinguishers.
Nature of Class of
Occupancy Fire Typical Examples
Lodging or rooming, one or two family houses, Private
dwellings dormitories,
LH Class A apartment houses, flats, upto 4 star hotels, etc
Small Kitchens having LPG connection, electrical heaters,
LH Class C etc.
Multi-storeyed buildings, multi-risk buildings, five star hotels,
MH Class A etc.
Tutorials, vocational training institutes, evening colleges,
LH Class A commercial institutes
MH Class A Schools, Colleges, etc

MH Class A Hospitals, sanatoria, homes for aged, orphanage jails, etc.


Theatres, Assembly halls, Exhibition halls, Museums,
Restaurants, Places of
Worship, Club rooms, Dance halls, etc., Having seating
capacity of over
HH Class A 100 persons

Theatres, Assembly halls, Exhibition halls, Museums,


Restaurants,
Places of Worship, Club rooms, Dance halls etc. Having
seating capacity less
MH Class A than 1000 persons

Theatres, Assembly halls, Exhibition halls, Museums,


Restaurants, Places of
Worship, Club rooms, Dance halls etc. but having
accommodation for more than
300 persons, but less than 1000 persons, with no permanent
seating
MH Class A arrangement

Theatres, Assembly halls, Exhibition halls, Museums,


Restaurants, Places of
Worship, Club rooms, Dance halls etc. but having
accommodation for more than
300 persons, but less than 1000 persons, with no permanent
seating
MH Class A arrangement

Theatres, Assembly halls, Exhibition halls, Museums,


Restaurants,
Places of Worship, Club rooms, Dance halls etc. Having
accommodation less
MH Class A than 300 and those not covered under D-1 to D-3
Offices, Banks, Record Rooms, Archives, Libraries, data
SH Class A processing centres, etc.
MH Class B Laboratories, research establishment, test houses etc.
SH Class A Computer installations
Shops, Stores, Markets, Departmental stores, Underground
shopping centres,
MH Class A etc.

LH Class A Small industrial units


Corrugated carton manufacturing units, Paper cane units,
Packing case
MH Class A manufacturing units, cotton waste manufacturing units.
Large number yards, saw mills godowns and warehouses
storing combustible
HH Class A materials, cold Storages, freight depots, etc.
Demonstration chemical plants, small chemical, processing
LH Class B plants, pilot plants, etc.

Workshops, painting shops, large kitchens, industrial


canteens, generator rooms,
heat treatment shops, tread rubber manufacturing units,
petrol bunks, tubes &
MH Class B flaps units, etc.,
Petroleum processing units, chemical plants, industrial
alcohol plants, effluent
HH Class B treatment plants etc.
LH Class C
MH Class C
HH Class C
HH Class D
Flammable liquid stores, storage in drums and cans in open,
paints and
MH Class B varnishes godown.
Tank farmes chemical and petroleum bulk storage depots,
large service stations,
truck and marine terminals, underground LDO/furnace oil
HH Class B storage yards, etc.
LPG distribution godown/office, distribution storage
godowns/offices of
MH Class C D, N, H, Argon and other industrial gases
Storage and handling of gas cylinders in bulk, gas plant, gas
holders (Horton),
HH Class C spheres, etc.

Buildings used for storage, handling, manufacture and


processing of highly
combustible explosive materials. (Risks involved in terms of
class of fire
and intensity of fire has to be assessed on case to case basis
and statutory
authorities to be consulted, environmental factors and mutual
aid facilities to be
taken into account before deciding on the fire extinguisher
requirements.)

ard.
One 9 litre
water
expelling
extinguisher or
ABC 5kg/6 kg
fire
extinguisher,
for every 200
m2 of floor
area or part
there of with
minimum of
two
extinguishers
per
compartment
or floor of the
building. The
extinguishers
should be
so located as
to be available
within 15 m
radious.

Two 9 litre
water
expelling
extinguisher or
ABC 5kg/6 kg
fire
extinguisher,
for every 200
m2 with
minimum of
4
extinguishers
per
compartment
or floor .The
extinguishers
should be so
located as to
be available
within 15 m
radious.
Provision as
per MH
occupancy, in
addition to one
50 litre water
CO2/ 25 kg
ABC fire
extinguisher
for every
100 m2 of
floor area or
part thereof.

One 4.5 kg
capacity
carbon dioxide
or one 2/3 kg
capacity clean
agent
extinguisher
for every 100
m2 of floor
area or part
there of with
minimum of
two
extinguishers
so located as
to be available
within 10 m
radious.
One 9 litre
foam
extinguisher,
mechanical or
BC or ABC, 5
kg / 6 kg fire
extinguisher,
for every 200
m2 of floor
area or part
there of with
minimum of
two
extinguishers
per
compartment
or floor. The
extinguishers
located as
to be available
within 15m
radious.

Two 9 litre
foam
extinguisher,
mechanical
type, or 5/6 kg
dry powder
extinguisher
(or one of
each type) for
every
200 m2 area
with minimum
of four
extinguisher
per
compertment.
Extinguisher
should be
available
within 15 m
radious.
Provision as
per MH, and in
addition to one
50 litre
mechanical
foam type
extinguisher or
25 kg BC fire
extinguisher
for every 100
m2 or part
thereof one
135 litre foam
mechanical
extinguisher
for every 300
m2 of
floor area or
part thereof.

One 2/3kg dry


powder of
clean agent
extinguisher
for every 20
m2 of floor
area or part
thereof;
extinguisher
available
within 15 m
radious.
One 10kg dry
powder
extinguisher(st
ored pressure)
or 6.5kg
carbon dioxide
extinguisher or
5kg clean
agent for
100 m2 of
floor area or
part thereof,
with minimum
of one
extinguisher of
the same type
for every
compartment;
extinguisher
should be
available
within a
radious of
15m, the
same type for
every
compartment;
extinguisher.
Dry powder
extinguisher
(stored
pressure) of
10 kg or 6.5
Kg CO2
extinguisher,
or 5 kg clean
agent
extinguisher
for every 100
m2 of floor
area or part
thereof,
subject to a
minimum of
two
extinguishers
of same type
per room
or
compartment.
Extinguishers
should be
available
within a radius
of 10 m.

One 10 kg dry
powder
extinguisher
with special
dry powder for
metal fires for
every 100 m2
of floor area or
part
thereof with
minimum of
two
extinguisher
per
compartment/
room.
Extinguishers
should be
available
within a
radius of 10m.
Circle Year
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15

PWD Bangalore Circle 2014-15


PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
Weighta
Description ge
Bruhat Bangalore Mahanagara Palike Limits (BBMP limits) a) For Buildings 6
Bruhat Bangalore Mahanagara Palike Limits (BBMP limits)b) For Roads and Bridges 8
BMRDA Limits- All taluks under Bangalore (Urban) and Bangalore (Rural) district and Ramanagara
District 3
Work carried out at bangalore Central Prison, Parappana Agrahara 10
Level-wise Percentage for hill stations MOTARABLE AREA 0-25 mtr. Nil
Level-wise Percentage for hill stations MOTARABLE AREA More than 25mtrs.- upto 150mtr. 5
Level-wise Percentage for hill stations MOTARABLE AREA More than 150mtrs. - upto 300 mtr. 10
Level-wise Percentage for hill stations MOTARABLE AREA More than 300mtrs. - upto 450 mtr. 15
Level-wise Percentage for hill stations MOTARABLE AREA More than 450mtrs. - upto 600 mtr. 20
Level-wise Percentage for hill stations MOTARABLE AREA Above 600mtr. 25
Other State Works a)Tirumala Hills (Andhra Pradesh) 25
Other State Works b)Ooty (Tamil Nadu) 25
Other State Works c)For other state works taken up by PW, P and IWTD 25
MINING Upto 5 Kms radius of mining area 4
Sugar Factory Area / Cement Factory Area (Upto 5 kms radius) 4
Forest Area 5
Chikkanayakanahally in Tumkur Dt. 3
Gubbi in Tumkur Dt. 2
Pavagada in Tumkur Dt. 2
Name Quantity uom
Filling Foundation with granite metal 1.00 Cum
Rubble stone masonry in foundation with mud 1.10 Cum
Mortar
Rubble stone masonry in foundation with 1.10 Cum
cement Mortar
Rubble stone in 1:8 in foundation with
masonry
cement Mortar in 1:6 1.10 Cum
Size stone masonry in basement with 1.05 Cum
mudMortar
Size stone masonry in foundation with 1.05 Cum
cement Mortar 1:8
Size stone masonry in foundation with 1.05 Cum
cement
Size stoneMortar 1:6 in basement with
masonry
1.440 Cum
cementMortar
Size stone masonry 1:6 in super structure with
cement mortar 1:6 1.449 Cum
Size stone masonry in super structure with 1.449 Cum
cement mortar 1:4
Hallow block masonry in cement mortar 1:4 12.11 Nos.
40x20x20
Hallow block cmsmasonry
50kg/sqcm in cement mortar 1:4 12.11 Nos.
40x20x20 cms 35kg/sqcm
Hallow block masonry in cement mortar 1:4
40x10x20 12.11 Nos.
Solid blockcms 35kg/sqcm
masonry in cement mortar 1:4
40x20x20 cms 35kg/sqcm 12.11 Nos.
Solid block masonry in cement mortar 1:4 12.11 Nos.
40x10x20 cms 35kg/sqm
Non modular CL35 brick masonry in mud mortar 485 sqm
for basement
Non modular CL35and super
brick structure
masonry in
cementmortar 1:8 for basement and super 485 cum
Non modular CL35 brick masonry in cementmortar 1:6 for basement and super
structure 485 cum
Non modular CL50 table moulded brick masonry
structure
in
Noncement
modular mortar
CL501:8 for moulded
table basementbrick
and masonry
super 485 cum
structure
in cement mortar 1:6 for basement and
Non modular CL50 table moulded brick masonry super 485 cum
structure
in cement mortar
Non modular CL751:4 for basement
machine moulded and super
brick 485 cum
structure
masonry in cement mortar 1:8 for basement
Non modular CL75 machine moulded brick and 456 cum
super structure
masonry in cement mortar 1:8 for basement and 456 cum
Non
supermodular
structure CL75 machine moulded brick
masonry in cement
Non modular CL75 machine mortar 1:4 for basement
moulded brick and 456 cum
super structure
masonry in cement mortar 1:3 for basement and 456 cum
super structure
modular CL35 brick msonry in cement
mortar 1:8 for basement and super structure 520 cum
modular CL35 brick masonry in cement 520 cum
modular
mortar 1:6CL50for table moulded
basement and brick
supermasonry
structurein
cement
modular mortar 1:6 for basement and super 520 cum
structureCL50 table moulded brick masonry in
cement
modularmortar 1:6 for
CL50 table basement
moulded brickand super in
masonry 520 cum
structure
cement
modularmortar 1:4 for basement
CL75 machine and super
moulded brick masonry 520 cum
structure
in cement mortar 1:8 for basement and super 520 cum
modular CL75 machine moulded brick masonry
structure
in cement mortar 1:6 for basement and super 520 cum
modular
structure CL75 machine moulded brick masonry
in cement mortar 1:4 for basement and super 520 cum
modular
structureCL75 machine moulded brick masonry
in cement mortar 1:3 for basement and super 520 cum
Nonmodular CL35 brick partition wall 11.2cms
structure
thick in cm 1:4
Nonmodular CL50
withtable
G I plastermesh
moulded brick partition 66.80 sqm
wall 11.2 cms thick in cm 1:4 with G I 66.80 sqm
Nonmodular CL35 brick partition wall 11.2 cms
plastermesh 66.80 sqm
thick in cm 1:4
Nonmodular CL50 table moulded brick partition 66.80 sqm
wall 11.2CL35
modular cms thick
brick in cm 1:4 wall 10 cms thick in
partition 56.70 sqm
cm 1:4 G CL50
modular I plastermesh
table moulded brick partition wall
10 cms thick in cm 1:4 with Gwall
I plastermesh 56.70 Sqm
modular CL35 brick partition 10 cms thick in
cm 1:4 56.70 Sqm
modular CL50 table moulded brick partition wall 58.70 Sqm
10 cms thick in cm 1:4
Providing and laying flooring with B.S. slab 10 cm 0.11 sqm
thick on sand bed 7.5 cm to 8 cm thick and pointed writer cm 1:3
Providing and laying flooring with B.S. slab 10 cm
thick on C.M.
Providing andbed
laying
1:6,flooring
25mm and
thicksteps
and pointed
machine 0.11 sqm
withgranite
cut C.M. 1:3
slabs 40mm thick on C.M. bed 1:6, - 0.11 sqm
25mm thick, and pointed with C.M. 1:3 over
Providing
existing ccand
bedlaying flooring and steps 0.11 sqm
fine
Providing andgranite
dressed laying flooring and steps 0.105 sqm
fine dressed granite
Providing & Laying heavy duty cobble stones (60mm) 0.105 sqm
Providing & Laying heavy duty cobble stones (75mm) 0.105 sqm
Flooring with 1:2:4cc 0.035 sqm
Flooring with 1:2:4cc with red oxide 0.026 sqm
Flooring 40mm thick with an underlay of 30mm thick cc1:2:4 0.026 sqm
Metallic floor hardner 2.6 kg 0.1 sqm
Metallic floor hardner 2.6 kg 0.043 sqm
marble chips 17.3 kgs, marble powder 0.0017
marble chips -0.56
cum pigment 17.3kgs
kgs, marble powder - 0.0017cum, 0.025 sqm
white cement - 0.16 kgs, pigment Sqm 0.025 0.0125 0.18 0.025 sqm
Marble chips - 17.3 kgs, white cement 0.08 bags,
334 0.025 sqm
marble powder - 0.0017 cum, pigment
marble chips - 17.3 kgs, white cement 0.16 kgs 0.025 sqm
marble powder - 0.0017 cum
Limesurkhi Mortar of mix 1:1 0.7125 Cum
Limesurkhi Mortar of mix 1:2 0.95 Cum
Limesurkhi Mortar of mix 1:3 1.07 Cum
Limesurkhi Sand Mortar of mix 1:1:1 0.475 Cum
Limesurkhi Sand Mortar of mix 1:1:2 0.357 Cum
Cement Mortar with Stone dust of mix 1:2 6.95 Cum
White cement Mortar with Marble 1:2 dust of mix 0.95 Cum
White cement Mortar with Marble dust of mix 1:3 1.07 Cum
White cement Mortar with Marble dust of mix1:4 1.07 Cum
White cement Mortar with Marble dust of mix 1:5 1.07 Cum
Fly ash sand Mortar of mix 1:1.5:3 0.357 Cum
Fly ash sand Mortar of mix 1:2:4 0.356 Cum
Fly ash sand Mortar of mix 1:2.5:5 0.356 Cum
Fly ash sand Mortar of mix 1:3.6:5 0.366 Cum
Cement mortar of mix 1:1 0.7125 Cum
Cement mortar of mix 1:2 0.95 Cum
Cement mortar of mix 1:3 1.07 Cum
Cement mortar of mix 1:4 1.07 Cum
Cement mortar of mix 1:5 1.07 Cum
Cement mortar of mix 1:6 1.07 Cum
Cement mortar of mix 1:8 1.07 Cum
Cement mortar of mix 1:10 1.07 Cum
Lime Mortar of mix 1:1 0.7125 Cum
Lime Mortar of mix 1:2 0.95 Cum
Lime Mortar of mix 1:3 1.07 Cum
Limesurkhi Sand Mortar of mix 1:1:1 0.475 Cum
Limesurkhi Sand Mortar of mix 1:1:2 0.357 Cum
Cement Lime Mortar of mix 1:1:3 0.86 Cum
Cement Lime Mortar of mix 1:1:4 1.07 Cum
Cement Lime Mortar of mix 1:1:5 1.07 Cum
Cement Lime Mortar of mix 1:1:6 1.07 Cum
Cement Lime Mortar of mix 1:1:7 1.07 Cum
Cement Lime Mortar of mix 1:1:8 1.07 Cum
Cement Lime Mortar of mix 1:2:9 1.07 Cum
Cement Lime Mortar of mix 1:3:2 1.07 Cum
Fly ash sand Mortar of mix 1:1.5:3 0.7150 Cum
Fly ash sand Mortar of mix 1:2:4 0.7150 Cum
Fly ash sand Mortar of mix 1:2.5:5 0.7150 Cum
Fly ash sand Mortar of mix 1:3.6:5 0.7150 Cum
Sand filling 1.0000 Cum
Filling Foundation with granite metal 0.50000 Cum
Sand cement bed with 5% cement 1.0000 Cum
Sand cement bed with 10% cement 1.0000 Cum
Sand Piles 0.0140 Cum
Sand cement Piles 0.014 Cum
Rubble stone masonry in foundation with mud
0.33 Cum
Mortar
Rubble stone masonry in foundation with
cement Mortar in 1:8 0.35 Cum
Rubble stone masonry in foundation with 0.35 Cum
cement Mortar in 1:6
Size stone masonry in foundation with mud 0.28 Cum
Mortar
Size stone masonry in foundation with 0.30 Cum
cement Mortar
Size stone masonry1:8 in foundation with
cement Mortar 1:6 in basement with 0.30 Cum
Size stone masonry
cementMortar 1:6 0.30 Cum
Size stone masonry in super structure with 0.30 Cum
cement mortar 1:6
Size stone masonry in super structure with 0.30 cum
cement mortar 1:4
Hallow block masonry in cement mortar 1:4 0.02 sqm
40x20x20 cmsmasonry
Hallow block 50kg/sqcm in cement mortar 1:4 0.02 sqm
40x20x20 cms 35kg/sqcm
Hallow block masonry in cement mortar 1:4
40x10x20 0.012 sqm
Solid blockcms 35kg/sqcm
masonry in cement mortar 1:4
40x20x20 cms 35kg/sqcm 0.02 sqm
Solid block masonry in cement mortar 1:4 0.012 sqm
40x10x20 cms 35kg/sqm
Non modular CL35 brick masonry in mud mortar 2.40 sqm
for basement
Non modular CL35
and super
brick structure
masonry in
cementmortar 1:8 for basement and super 0.26 cum
Non modular CL35 brick masonry in
structure
cementmortar
Non modular CL50 1:6 for
tablebasement
mouldedand super
brick masonry 0.26 cum
structure
in cement mortar 1:8 for basement and
Non modular CL50 table moulded brick masonry super 0.26 cum
structure
in
Noncement
modularmortar
CL501:6 for moulded
table basementbrick
and masonry
super 0.26 cum
structure
in cement mortar 1:4 for basement and super 0.26 cum
Non modular CL75 machine moulded brick
structure
masonry in cement mortar 1:8 for basement
Non
supermodular
structureCL75 machine moulded brick and 0.26 cum
masonry
Non modular CL75 machine moulded brick and
in cement mortar 1:8 for basement 0.26 cum
super
masonrystructure
in cement mortar 1:4 for basement
Non modular CL75 machine moulded brick and 0.26 cum
super structure
masonry in cement mortar 1:3 for basement and 0.26 cum
super structure
modular CL35 brick msonry in cement 0.225 cum
mortar 1:8
modular CL35 for brick
basement
masonryandin
super structure
cement 0.225 cum
mortar 1:6
modular CL50
for table
basement
mouldedand brick
supermasonry
structurein
cement
modular mortar
CL50 1:6 for
table basement
moulded brickand super in
masonry 0.225 cum
structure
cement
modularmortar 1:6 for
CL50 table basement
moulded brickand super in
masonry 0.225 cum
structure
cement
modularmortar 1:4 for basement
CL75 machine and super
moulded brick masonry 0.225 cum
structure
in cement mortar 1:8 for basement and super 0.225 cum
structure
modular CL75 machine moulded brick masonry
in cementCL75
modular mortar 1:6 formoulded
machine basement andmasonry
brick super 0.225 cum
structure
in cement mortar 1:4 for basement and super 0.225 cum
modular CL75 machine moulded brick masonry
structure
in cement mortar 1:3 for basement and super 0.225 cum
Nonmodular CL35 brick partition wall 11.2cms
structure 0.026 sqm
thick in cm 1:4
Nonmodular CL50
withtable
G I plastermesh
moulded brick partition
wall 11.2 cms thick in cm 1:4 with G I 0.026 sqm
Nonmodular CL35 brick partition wall 11.2 cms
plastermesh
thick in cm 1:4 0.026 sqm
Nonmodular CL50 table moulded brick partition
wall 11.2 cms thick in cm 1:4 0.026 sqm
modular CL35 brick partition wall 10 cms thick in 0.022 sqm
cm 1:4 G I plastermesh
modular CL50 table moulded brick partition wall 0.022 sqm
10 cms thick
modular CL35inbrick
cm 1:4 with Gwall
partition I plastermesh
10 cms thick in 0.022 sqm
cm 1:4
modular CL50 table moulded brick partition wall 0.022 sqm
10 cms thick
Providing andinlaying
cm 1:4flooring with B.S. slab 10 cm
Providing
thick on and
sand laying
bed 7.5flooring
cm to 8with B.S. slab
cm thick 10 cm writer cm 1:3 0.0088 sqm
thick on C.M.
Providing andbed 1:6,flooring
laying 25mm thick
and and and
steps
pointed
pointed
machine 0.0043 sqm
with C.M. 1:3
cut granite slabs 40mm thick on C.M. bed 1:6, - 0.0033 sqm
25mm thick, and pointed with C.M. 1:3 over
Providing
existing ccand
bedlaying flooring and steps 0.0031 sqm
fine dressed
Providing andgranite
laying flooring and steps
0.0028 sqm
fine dressed granite
Providing & Laying heavy duty cobble stones (60mm) 0.005 sqm
Providing & Laying heavy duty cobble stones (75mm) 0.005 sqm
Flooring with 1:2:4cc 0.018 sqm
Flooring with 1:2:4cc with red oxide 0.025 sqm
Flooring 40mm thick with an underlay of 30mm thick cc1:2:4 0.025 sqm
Metallic floor hardner 2.6 kg 0.016 sqm
Metallic floor hardner 2.6 kg 0.02 sqm
Tandoor blue slab 1.15 sqm, pigment 0.45 kg 0.028 sqm
Shahabad slab 1.15 sqm, pigment 0.45 kg 0.028 sqm
cudapa slab 1.15 sqm, pigment 0.45 kg 0.028 sqm
marble chips 17.3 kgs, marble powder 0.0017
cum pigment 0.012 sqm
marble chips -0.56
17.3kgskgs, marble powder - 0.0017cum,
white cement - 0.16 kgs, pigment 0.0125 sqm
Marble chips - 17.3 kgs, white cement 0.08 bags, 0.0125 sqm
marble powder - 0.0017 cum, pigment
marble chips - 17.3 kgs, white cement 0.16 kgs 0.012 sqm
marble powder - 0.0017 cum
mosaic tiles - 1.1 sqm, pigment - 0.30 kgs 0.028 sqm
white cement - 0.08 bags, pigment - 0.30 kgs 0.028 sqm
mosaic tiles - 1.1 sqm, white cement - 0.04 bags,
pigment - 0.30tiles
kgs - 1.10 sqm, 0.028 sqm
white mosaic
white cement - 0.17 bags 0.028 sqm
checkered mosaic tiles - 1.10 sqm, pigment - 0.3 kgs 0.013 sqm
checkered mosaic tiles - 1.10 sqm, 0.013 sqm
white
mosaiccement - 0.088
tiles - 1.10 sqm,bags, pigment
white cement- 0.3 kgsbags,
- 0.04
0.013 sqm
pigment - 0.30 kgs
mosaic tiles - 1.10 sqm, white cement - 0.17 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
marble slabs - 1.15 sqm, white cement - 0.01 bags 0.028 sqm
. 0.02 sqm
red oxide - 0.28 kg 0.02 sqm
glazed tiles - 46 nos. 0.01 sqm
glazed tiles - 46 nos. 0.01 sqm
glazed tiles - 46 nos. 0.01 sqm
glazed tiles - 46 nos. 0.01 sqm
marble slab - 1.15 sqm 0.012 sqm
Finishing Work 0.002 sqm
Finishing Work 0.002 sqm
Finishing Work 0.002 sqm
Finishing Work 0.002 sqm
Finishing Work 0.004 sqm
Finishing Work 0.004 sqm
Finishing Work 0.001 sqm
Finishing Work 0.001 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.013 sqm
Finishing Work 0.013 sqm
Providing tough cement plastering cm 1:4 0.017 sqm
Providing tough cement plastering cm 1:6 0.017 sqm
Marble chips - 0.87 kgs, 0.031 sqm
marble powder - 0.0007 cum, pigment - 0.285 kgs
White cement - 0.41 kg, Marble chips - 0.87 kgs, 0.03 sqm
Marble powder- -0.04
White cement 0.0007 cum,
bags, pigment
Marble chips- -0.285 kgs
8.7 kgs, 0.03 sqm
Marble powder- -0.08
White cement 0.0007 cum,
bags, pigment
Marble chips- -0.28 kgs
8.7 kgs,
Marble powder - 0.0007 cum 0.03 sqm
Mosaic tiles - 1.10 sqm 0.012 sqm
Mosaic tiles - 1.10 sqm, pigment 0.462 kgs 0.012 sqm
Mosaic tiles - 1.10 sqm, white cement - 0.066 bags, pigment 0.55 kgs 0.01 sqm
Mosaic tiles - 1.10 sqm, white cement - 0.13 bags 0.01 sqm
Repairs to Building 0.0010 Sqm
Repairs to Building 0.0010 Sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.0050 sqm
Repairs to Building 0.0200 sqm
Repairs to Building 0.0020 sqm
Repairs to Building 0.0020 sqm
Cement Mortar of mix 1:1 1020.00 Kgs
Cement Mortar of mix 1:2 680.00 Kgs
Cement Mortar of mix 1:3 510.00 Kgs
Cement Mortar of mix 1:4 380.00 Kgs
Cement Mortar of mix 1:5 310.00 Kgs
Cement Mortar of mix 1:6 250.00 Kgs
Cement Mortar of mix 1:8 190.00 Kgs
Cement Mortar of mix 1:10 150.00 Kgs
Lime Mortar of mix 1:1 451.00 Kgs
Lime Mortar of mix 1:2 301.00 Kgs
Lime Mortar of mix 1:3 226.00 Kgs
Limesurkhi Mortar of mix 1:1 451.00 Kgs
Limesurkhi Mortar of mix 1:2 301.00 Kgs
Limesurkhi Mortar of mix 1:3 226.00 Kgs
Limesurkhi Sand Mortar of mix 1:1:1 301.00 Kgs
Limesurkhi Sand Mortar of mix 1:1:2 226.00 Kgs
Cement Mortar with Stone dust of mix 1:2 680.00 Kgs
Cement Lime Mortar of mix 1:1:3 410.00 Kgs
Cement Lime Mortar of mix 1:1:3 181.00 Kgs
Cement Lime Mortar of mix 1:1:4 380.00 Kgs
Cement Lime Mortar of mix 1:1:4 170.00 Kgs
Cement Lime Mortar of mix 1:1:5 310.00 Kgs
Cement Lime Mortar of mix 1:1:5 135.00 Kgs
Cement Lime Mortar of mix 1:1:5 250.00 Kgs
Cement Lime Mortar of mix 1:1:6 113.00 Kgs
Cement Lime Mortar of mix 1:1:6 220.00 Kgs
Cement Lime Mortar of mix 1:1:7 97.00 Kgs
Cement Lime Mortar of mix 1:1:7 190.00 Kgs
Cement Lime Mortar of mix 1:1:8 84.00 Kgs
Cement Lime Mortar of mix 1:1:8 170.00 Kgs
Cement Lime Mortar of mix 1:2:9 151.00 Kgs
Cement Lime Mortar of mix 1:2:9 130.00 Kgs
Cement Lime Mortar of mix 1:3:2 170.00 Kgs
White cement Mortar with Marble 1:2 dust of mix 680.00 Kgs
White cement Mortar with Marble dust of mix 1:3 510.00 Kgs
White cement Mortar with Marble dust of mix 1:4 380.00 Kgs
White cement Mortar with Marble dust of mix 1:5 310.00 Kgs
Fly ash sand Mortar of mix 1:1.5:3 340.00 Kgs
Fly ash sand Mortar ofmix 1:2:4 250.00 Kgs
Fly ash sand Mortar of mix 1:2.5:5 200.00 Kgs
Fly ash sand and Mortar of mix 1:3:6:5 160.00 Kgs
Sand cement bed with 5% cement 71.40 Kgs
Sand cement bed with 10% cement 142.80 Kgs
Sand cement Piles 2.00 Kgs
KSRB 4.1.1: Providing and laying ...... cement concrete of mix M15 240.00 Kgs
KSRB 4.1.2 : Providing and laying ...... cement concrete of mix M10 220.00 Kgs
KSRB 4.1.3 : Providing and laying ...... cement concrete of mix M 7.5 180.00 Kgs
KSRB 4.1.4 : Providing and laying ...... cement concrete of mix M 5 160.00 Kgs
KSRB 4.1.5 : Providing and laying ...... cement concrete of mix M 20 300.00 Kgs
KSRB 4.1.6 : Providing and laying ...... cement concrete of mix M 15 240.00 Kgs
KSRB 4.1.7 : Providing and laying ...... cement concrete of mix M 10 220.00 Kgs
KSRB 4.2.1 : Providing and laying ...... cement concrete of mix M 25 340.00 Kgs
KSRB 4.2.2 : Providing and laying ...... cement concrete of mix M 20 320.00 Kgs
KSRB 4.2.3 : Providing and laying ...... cement concrete of mix M 15 240.00 Kgs
KSRB 4.2.4 : Providing and laying ...... cement concrete of mix M 10 220.00 Kgs
KSRB 4.2.9 : Providing and laying ...... cement concrete of mix M 15 240.00 Kgs
KSRB 4.2.10 : Providing and laying ...... cement concrete of mix M 20 24.00 Kgs
KSRB 4.2.11 : Providing and laying ...... cement concrete of mix M 20 27.20 Kgs
Providing and laying readymix concrete ...... M20 320.00 Kgs
Providing and laying readymix concrete ...... M25 340.00 Kgs
Providing and laying readymix concrete ...... M30 360.00 Kgs
Providing and laying readymix concrete ...... M35 390.00 Kgs
Providing and laying readymix concrete ...... M40 420.00 Kgs
Providing and casting reinforced CC racks ...... M20 16.00 Kgs
Providing RCC loft (atta) 30.00 Kgs
Providing RCC loft (atta) 30.00 Kgs
Rubble stone masonry in foundation with 62.70 Kgs
cement Mortar
Rubble stone in 1:8 in foundation with
masonry 82.50 Kgs
cement Mortar in 1:6
Size stone masonry in foundation with
cement Mortar 1:8 in foundation with 53.20 Kgs
Size stone masonry
cement Mortar 1:6 70.00 Kgs
Size stone masonry in basement with 70.00 Kgs
cementMortar 1:6
Size stone masonry in super structure with 70.00 Kgs
cement mortar 1:6
Size stone masonry in super structure with 106.40 Kgs
cement mortar
Hallow block 1:4
masonry in cement mortar 1:4 7.36 Kgs
40x20x20 cms 50kg/sqcm
Hallow block masonry in cement mortar 1:4
40x20x20 cmsmasonry
35kg/sqcm 7.38 Kgs
Hallow block in cement mortar 1:4
40x10x20 cms 35kg/sqcm 4.09 Kgs
Solid block masonry in cement mortar 1:4 7.38 Kgs
40x20x20 cms 35kg/sqcm
Solid block masonry in cement mortar 1:4 4.09 Kgs
40x10x20 cms 35kg/sqm
Providing and fixing pre cast solid concrete kerb size 450x200x400x500mm 11.72 Kgs
Providing and fixing pre cast solid concrete kerb size 450x150x500mm 11.00 Kgs
Providing andCL35
Non modular fixingbrick
pre cast solid in
masonry c.c kerb stones 8.235 Kgs
cementmortar 1:8 for basement and super 45.60 Kgs
Non modular CL35 brick masonry in
structure
cementmortar 1:6 for basement and super 60.00 Kgs
Non modular CL50 table moulded brick masonry
structure
in
Noncement mortar
modular CL501:8 for moulded
table basementbrickand masonry
super 45.60 Kgs
structure
in
Noncement mortar
modular CL501:6 for moulded
table basementbrickand masonry
super 60.00 Kgs
structure
in cement mortar
Non modular CL751:4 for basement
machine moulded and super
brick 91.20 Kgs
structure
masonry in cement mortar 1:8 for basement and 45.60 Kgs
super structure
Non modular CL75 machine moulded brick
masonry in cement
Non modular mortar 1:8
CL75 machine for basement
moulded brick and 80.00 Kgs
super
masonrystructure
Non modular CL75 machine moulded brick and
in cement mortar 1:4 for basement 91.20 Kgs
super
masonrystructure
in cement mortar 1:3 for basement and 122.40 Kgs
super structure
modular CL35 brick msonry in cement 39.90 Kgs
mortar
modular1:8 for brick
CL35 basement andin
masonry super structure
cement 52.50 Kgs
mortar 1:6
modular CL50
for table
basement
moulded
and brick
supermasonry
structurein
cement
modular mortar 1:6 for basement and super 39.90 Kgs
structureCL50 table moulded brick masonry in
cement
modularmortar 1:6 for
CL50 table basement
moulded brickand super in
masonry 52.50 Kgs
structure
cement
modularmortar 1:4 for basement
CL75 machine and super
moulded brick masonry 79.80 Kgs
structure
in cement mortar 1:8 for basement and super 39.90 Kgs
modular
structure CL75 machine moulded brick masonry
in cement mortar 1:6 for basement and super 52.50 Kgs
modular
structure CL75 machine moulded brick masonry
in cementCL75
modular mortar 1:4 formoulded
machine basement andmasonry
brick super 79.80 Kgs
structure
in cement mortar 1:3 for basement and super 107.10 Kgs
structure 9.12 Kgs
Nonmodular CL35 brick partition wall 11.2cms thick in cm 1:4 with G I plastermesh
Nonmodular CL50 table moulded brick partition wall 11.2 cms thick in cm 1:4 with 9.12 Kgs
GI Plasermesh
Nonmodular CL35 brick partition wall 11.2 cms thick in cm 1:4 9.12 Kgs
Nonmodular CL 50 table moulded brick partion wall 11:2 cms thick in cm 1:4 9.12 Kgs
modular CL35 brick partition wall 10 cms thick in 7.98 Kgs
cm 1:4 G I plastermesh
modular CL50 table moulded brick partition wall 7.98 Kgs
10 cms thick in cm 1:4 with G I plastermesh
modular CL35 brick partition wall 10 cms thick in 7.98 Kgs
cm 1:4 CL50 table moulded brick partition wall
modular 7.98 Kgs
10 cms thick in cm 1:4
KSRB 12-5.1: Construction brick masonry circular type manhole 0.91 m internal dia 300.00 Kgs
KSRB 12.5.2 - -do- 1.67m 362.00 Kgs
KSRB 12-5.3 : -do- 1.22m internal dia 553.00 Kgs
KSRB 12-5.4: -do- 2.29m deep 633.00 Kgs
KSRB 12-5.5 : Construction brick masonry circular type manhole 1.52 m internal dia 1000.00 Kgs
KSRB 12-5.6 -do- bottom 4.18m 1615.00 Kgs
KSRB 12-5.7 : construction circular type manhole 1500mm internal dia 880.00 Kgs
KSRB 12-8.1: Extra for item No. KSRB 12-8.1 depth beyond 450mm 11.30 Kgs
KSRB 12-8.2 : constructing brick masonry inspection chamber 500x700mm and 96.00 Kgs
450mm depth
KSRB 12-8.2.1 : Extra for item No. KSRB 12-8.2 depth beyond 450mm and brick 12.30 Kgs
masonry
KSRB 12-8.3: Construction brick masonry inspection chamber 600x850mm and 120.00 Kgs
450mm depth
KSRB 12-8.3.1: Extra for item No. KSRB 12-8.3 depth beyond 450 mm and brick 14.20 Kgs
Providing and laying flooring with B.S. slab 10 cm thick on sand bed 7.5 cm to 8 cm
thick 6.60 Kgs
Providing and laying flooring with B.S. slab 10 cm thick on C.M. bed 1:6, 25mm thick
and pointed with C.M. 1:3 13.40 Kgs
Providing and laying flooring and steps machine cut granite slabs 40mm thick on 8.80 Kgs
C.M. bed 1:6, - 25mm thick, and pointed with C.M. 1:3 over existing cc bed
Providing and laying flooring and steps fine dressed granite 8.25 Kgs
-do- 7.55 Kgs
Flooring with 1:2:4cc 15.00 Kgs
Flooring with 1:2:4cc with red oxide 20.00 Kgs
Flooring 40mm thick with an underlay of 30mm thick cc1:2:4 20.00 Kgs
Metallic floor hardner 2.6 kg 18.50 Kgs
Metallic floor hardner 2.6 kg 25.00 Kgs
Tandoor blue slab 1.15 sqm, pigment 0.45 kg 13.00 Kgs
Shahabad slab 1.15 sqm, pigment 0.45 kg 13.00 Kgs
cudapa slab 1.15 sqm, pigment 0.45 kg 13.00 Kgs
marble chips 17.3 kgs, marble powder 0.0017 cum pigment 0.56 kgs 17.00 Kgs
marble chips - 17.3 kgs, marble powder - 0.0017cum, white cement - 0.16 kgs, 9.00 Kgs
pigment
Marble chips - 17.3 kgs, white cement 0.08 bags, marble powder - 0.0017 cum, 9.00 Kgs
pigment
marble chips - 17.3 kgs, white cement 0.16 kgs marble powder - 0.0017 cum 9.00 Kgs
mosaic tiles - 1.1 sqm, pigment - 0.30 kgs 15.50 Kgs
white cement - 0.08 bags, pigment - 0.30 kgs 11.00 Kgs
mosaic tiles - 1.1 sqm, white cement - 0.04 bags, pigment - 0.30 kgs 13.00 Kgs
white mosaic tiles - 1.10 sqm, white cement - 0.17 bags 6.50 Kgs
checkered mosaic tiles - 1.10 sqm, pigment - 0.3 kgs 15.00 Kgs
checkered mosaic tiles - 1.10 sqm, white cement - 0.088 bags, pigment - 0.3 kgs 11.00 Kgs
mosaic tiles - 1.10 sqm, white cement - 0.04 bags, pigment - 0.30 kgs 13.00 Kgs
mosaic tiles - 1.10 sqm, white cement - 0.17 bags 6.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
marble slabs - 1.15 sqm, white cement - 0.01 bags 11.00 Kgs
. 10.00 Kgs
red oxide - 0.28 kg 10.00 Kgs
glazed tiles - 46 nos. 9.00 Kgs
glazed tiles 46 nos. 9.00 Kgs
glazed tiles 46 nos. 9.00 Kgs
glazed tiles 46 nos. 9.00 Kgs
marble slab - 1.15 sqm 11.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.90 Kgs
Finishing Work 1.90 Kgs
Finishing Work 0.75 Kgs
Finishing Work 0.75 Kgs
Finishing Work 6.50 Kgs
Finishing Work 4.90 Kgs
Finishing Work 3.00 Kgs
Finishing Work 8.00 Kgs
Finishing Work 6.00 Kgs
Finishing Work 4.00 Kgs
Finishing Work 10.00 Kgs
Finishing Work 7.50 Kgs
Finishing Work 4.95 Kgs
Finishing Work 11.00 Kgs
Finishing Work 8.00 Kgs
Finishing Work 5.50 Kgs
Finishing Work 6.50 Kgs
Finishing Work 4.90 Kgs
Providing tough cement plastering cm 1:4 6.25 Kgs
Providing tough cement plastering cm 1:6 4.00 Kgs
Providing flooring coat of cement 1.40 Kgs
. 0.10 Kgs
Linseed oil 0.08 ltr. 0.10 Kgs
Marble chips - 0.87 kgs, marble powder - 0.0007 cum, pigment - 0.285 kgs 18.50 Kgs
White cement - 0.41 kg, Marble chips - 0.87 kgs, Marble powder - 0.0007 cum, 15.00 Kgs
pigment - 0.285 kgs
White cement - 0.04 bags, Marble chips - 8.7 kgs, Marble powder - 0.0007 cum, 17.00 Kgs
pigment - 0.28 kgs
White cement - 0.08 bags, Marble chips - 8.7 kgs, Marble powder - 0.0007 cum 15.00 Kgs
Mosaic tiles - 1.10 sqm 12.90 Kgs
Mosaic tiles - 1.10 sqm, pigment 0.462 kgs 12.90 Kgs
Mosaic tiles - 1.10 sqm, white cement - 0.066 bags, pigment 0.55 kgs 9.60 Kgs
Mosaic tiles - 1.10 sqm, white cement - 0.13 bags 6.00 Kgs
Repairs to Building 0.00110 Kgs
Repairs to Building 0.00110 Kgs
Repairs to Building 0.50 Kgs
Repairs to Building 10.20 Kgs
Repairs to Building 10.20 Kgs
Repairs to Building 7.60 Kgs
Repairs to Building 7.60 Kgs
Repairs to Building 5.00 Kgs
Repairs to Building 1.25 Kgs
Repairs to Building 10.00 Kgs
Repairs to Building 0.75 Kgs
Repairs to Building 0.50 Kgs
KSRRB M-600-1 : Construction of dry lean cement concrete mix M-5 160.00 Kgs
KSRRB M-600-2 : Construction of unreinforced, dowen jointed, plain cement
concrete pavement M-30 360.00 Kgs
KSRRB M-600-2 : Construction of unreinforced, dowen jointed, plain cement 420.00 Kgs
concrete pavement M-40
KSRRB M-600-3 : Construction of rolled cement concrete mix M7.5 OPC cement 180.00 Kgs
KSRRB M 600-5: Construction of base sub-base mix M5 OPC cement 160.00 Kgs
KSRRB M600-6. Construction of reinforced, dowel jointed, plain cement concrete 360.00 Kgs
pavement M30 pavement, construction of un-reinforced plain cement concrete
Cement concrete
M-30 360.00 Kgs
Cement concrete pavement, construction of un-reinforced plain cement concrete
M-20 300.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 1000mm dia piles - M20 320.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 1000mm dia piles - M30 360.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 1000mm dia piles - M35 390.00 Kgs
KSRRB 1100.2 Driving cast-in- place vertical RCC 500mm dia - M20 320.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 500mm dia piles - M30 360.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 500mm dia piles - M35 390.00 Kgs
KSRRB M-1100-3.1 Bored cast-in-situ RCC Pile with OPC - M35 390.00 Kgs
KSRRB M1100-3.2 -do- B. Pile diametre = 1000mm- M35 390.00 Kgs
KSRRB M1100.3.3 -do- C.pile diametre = 1200 mm - M35 390.00 Kgs
KSRRB M1100-4.1 Driven cast-in-place vertical RCC Pile with OPC cement design mix 390.00 Kgs
M35
KSRRB - M1100-4.2 - DO- pile diametre = 1000mm 390.00 Kgs
KSRRB M1100-4.3 -do- pile diametre = 1200mm 390.00 Kgs
KSRRB M1100-4.4 - Driven precast vertical RCC piles with OPC cement design mix 390.00 Kgs
M35 - file diametre = 500mm
KSRRB M1100-4.5 -do- Pile diametre = 750mm M35 390.00 Kgs
KSRRB M1100-4.6 -Do- pile diametre = 1000mm M35 390.00 Kgs
KSRRB M-1100-4.7 Driven precast vertical RCC Piles with OPC cement deisgn mix 390.00 Kgs
M35 - size of pile = 300mm x 300mm
KSRRB M1100-4.8 -do- size of pile = 500mm x 500mm - M35 390.00 Kgs
KSRRB M1100-4.9 : -do- size of pile = 750mm x 750mm - M35 390.00 Kgs
KSRRB M1100-8.1: Cement Concrete for reinforced concrete in pile cap as per 320.00 Kgs
drawing and technical specifcation complete A.RCC with OPC cement design M20
KSRRB M1100-8.2 -do A. RCC with OPC cement design mix M-20 320.00 Kgs
KSRRB M1100-9.1 Cement concrete for reinforced concrete inm pile cap as per 340.00 Kgs
drawing and technical specifications - B RCC with OPC Cement design mix M25
KSRRB M1100-9.2 : -do- RCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1100-10.1 : Cement concrete for reinforcement concrete in pile cap per
drawing and technical specification - C. RCC with OPC cement design mix M30 360.00 Kgs
KSRRB M-1100-10.2 -do- C. RCC with OPC cement design mix M30 360.00 Kgs
KSRRB M1100-11.1 : Cement concrete for reinforced concrete in Pile Cap complete 390.00 Kgs
as per drawing - D. RCC with OPC cement design mix M35
KSRRB M1100-11.2 : -do- D. RCC with OPC cement design mix M35 390.00 Kgs
KSRRB M1100-12 Providing and laying of PCC M15 levelling course 100mm thick
240.00 Kgs
below
KSRRB M1200-3.1 i) RCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200.3.2 ii) -do- with M-25 340.00 Kgs
KSRRB M1200-3.3 iii) RCC with OPC cement design mix M35 390.00 Kgs
KSRRB M1200-4.1 : i) PCC design mix M15 with
OPC cement 240.00 Kgs
KSRRB M1200-4.2 ii) PCC with OPC cement design mix M20 300.00 Kgs
KSRRB M1200-4.3 iii) RCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200-4.4: iv) PCC with OPC cement design mix M25 340.00 Kgs
KSRRB M-1200-4.5 : v) RCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1200-4.6 vi) PCC with OPC cement design mix M30 360.00 Kgs
KSRRB M-1200-4.7 vii) RCC with OPC cement design mix M30 360.00 Kgs
KSRRB M1200-4.8 viii) RCC with OPC cement design mix M35 390.00 Kgs
KSRRB M1200-4.9 ix) RCC with OPC cement design mix M40 420.00 Kgs
KSRRB M1200-5.1 : Plain / Reinforced cement concrete, in well foundation 320.00 Kgs
complete as per drawing and technical specification mix M20
KSRRB M1200-5.2 : Plain / reinforced cement concrete, in well foundation complete 320.00 Kgs
as per drawing- M 20
KSRRB M1200-6.1: Plain/reinforced cement concrete, in well foundation complete 340.00 Kgs
ii) PCC with
KSRRB OPC cement
M1200-6.2: Plain /design mix M25
reinforced cement concrete, in well foundation complete 340.00 Kgs
mix M25
KSRRB M1200-7.1: Plain/ reinforced cement concrete, in well foundation design mix
M30 360.00 Kgs
KSRRB M1200-7.2 : Plain/ reinforced cement concrete, in well foundation complete
as per drawing design mix M30 360.00 Kgs
KSRRB M1200-8.1: Plain/ reinforced cement concrete, in well foundation complete 390.00 Kgs
as per drawing iv) PCC with OPC cement design mix M35
KSRRB M1200-8.2: Plain/ reinforced cement concrete, in well foundation complete 390.00 Kgs
as per drawing and Techical specifcation PCC with OPC cement design mix M35
KSRRB M1200-9.1 (i) PCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200-9.2 (ii) PCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1200-9.2 (ii) PCC with OPC cement design mix M30 360.00 Kgs
E-Top Plug : KSRRB M1200-10.1 (i) i) PCC design mix M15 with OPC cement 240.00 Kgs
KSRRB M1200-10.2 : (ii) PCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200-10.3 : (iii) PCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1200-10.4: (iv) PCC with OPC cement design mix M30 360.00 Kgs
KSRRB M1200-11.1 : Plain/reinforcement cement concrete, in well foundation 320.00 Kgs
F.well cap i) RCC with OPC cement design mix M20
KSRRB M1200-11.2 : Plain/reinforced cement concrete, in well foundation complete 320.00 Kgs
as per drawing and technical specification i) RCC with OPC cement design mix M20
KSRRB M1200-11.3 : Plain/reinforced cement concrete, in well foundation complete
as per drawing
KSRRB M1200-11.4
and technical
: Plain / reinforced
specification
cement
i) RCCconcrete,
with OPCincement
well foundation
design mix M20 320.00 Kgs
complete as per drawing
KSRRB M1200-11.5 and
: Plain/ technicalcement
reinforced specification (ii) RCC
concrete, withfoundation
in well OPC cement 340.00 Kgs
design mixasM25
complete per drawing and technical specification (iii) RCC with OPC cement 360.00 Kgs
KSRRB
design M1200-11.6
mix M30 : Plain / Reinforced cement concrete, in well foundation
complete as per drawing and technical specification: RCC with OPC cement design 360.00 Kgs
KSRRB
mix M30M1200-11.7: Plain / Reinforced cement concrete, in well foundation
complete as per drawing and technical specification (iv) RCC with OPC cement 390.00 Kgs
design M1200-11.8:
KSRRB mix M35 Plain/ reinforced cement concrete, in well foundation complete
as per drawing and technical specification: 390.00 Kgs
KSRRB M1200-12. Plain/ reinforced cementRCC with OPC
concrete cement
in well design complete
foundation mix M35 as
per drawing and technical specification (v) RCC with OPC cement design mix M40 420.00 Kgs
KSRRB M1200-48.1 : Construction of cement concrete kerb with top and bottom 15.83 Kgs
width 115 and 165mm respectively 250mm high in M-20 grade PCC on M10 Grade
KSRRB M1200-48.2 Construction of cement concrete kerb with top and bottom 15.83 Kgs
width 115
KSRRB M1200-49.1:
and 165mm Cast-in-Situ
respectively
cement
250mmconcrete
high inM20
M20kerbgrade
with
PCCchannel,
on M10
construction of cement concrete kerb with channel with top and bottom with 115 30.03 Kgs
and 165mm
KSRRB M1200-49.2. Cast-in-situ cement concrete M20 kerb with channel 30.03 Kgs
KSRRB M2100-10 Plain cement concrete M10 with OPC cement 220.00 Kgs
KSRRB M2100-11. Brick Masonry work in cement mortar 1:3 in foundation complete 122.40 Kgs
excluding pointing and plastering
KSRRB M2100-13: plain/reinforced cement concrete M15 with OPC cement 240.00 Kgs
KSRRB M2100-14 : Plain / reinforcement cement concrete M20 with OPC cement 300.00 Kgs
KSRRB M2100-15.1 : Plain/ Reinforcement cement concrete M-20 with OPC cement 320.00 Kgs
KSRRB M2100-15.2 : Plain/ reinforcement cement concrete M20 with OPC cement 320.00 Kgs
KSRRB M2100-16.1 Plain/ reinforced cement concrete design mix M25 with OPC 340.00 Kgs
cement
KSRRB M2100-16.2 : Plain / reinforced cement concrete idesign mix M25 with OPC 340.00 Kgs
cement
KSRRB M2100-17.1 : Plain/ reinforced cement concrete idesign mix M25 with OPC 340.00 Kgs
cement
KSRRB M2100-17.2 : Plain /reinforced cement concrete idesign mix M25 with OPC
cdement 340.00 Kgs
KSRRB M2100-8.1: Plain reinforced cement concrete in open foundation with OPC
cement design mix M30 360.00 Kgs
KSRRB M2100-18.2 : Plain / reinforced cement concrete in open foundation with 360.00 Kgs
OPC cement design mix M30
KSRRB M2100-19.1: Plain / reinforcement cement concrete in open foundation with 360.00 Kgs
OPC cement design mix M30
KSRRB M2100-19.2: Plain / reinforced cement concrete in open foundation with 360.00 Kgs
OPC
KSRRBcement design :mix
M2100-20.1 M30
Plain/ reinforcement in open foundation with OPC cement 390.00 Kgs
design mix M35
KSRRB M2100-20.2 : Plain/ reinforced cement concrete in open foundation with
OPC cement design mix M35 390.00 Kgs
KSRRB M2200-1 : Brick Masonry in 1:3 29.37 Kgs
KSRRB M2200-2 : Painting 1.53 Kgs
KSRRB M2200-3 : Plastering 7.34 Kgs
KSRRB M2200-4.1 :Stone Masonry in CM 1:3 168.30 Kgs
KSRRB M2200-4.2 : Coursed Rubble Masonry 153.00 Kgs
KSRRB M2200-4.3 : Ashlar Masonry 168.30 Kgs
KSRRB M2200-5.1 : M15 with OPC cement 240.00 Kgs
KSRRB M2200-5.2 : Design mix M20 with OPC cement 300.00 Kgs
KSRRB M2200-5.3 Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.4: Design mix M25 @ with OPC cement 340.00 Kgs
KSRRB M2200-5.5 : Design mix M25 with OPCcement 340.00 Kgs
KSRRB M2200-5.6 : Design mix M30 with OPCcement 360.00 Kgs
KSRRB M2200-5.7: Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.8 Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.9: Design mix M20 with OPC cement 320.00 Kgs
KSRRB M2200-5.10 - Design mix M20 with OPC cement 320.00 Kgs
KSRRB M2200-5.11: Design mix M20 with OPC cement 320.00 Kgs
KSRRB M2200-5.12 : Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.13: Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.14 : Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.15: design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.16: Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.17: Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.18 : Design mix M35 with OPC cement 390.00 Kgs
KSRRB M2200-5.19: Design mix M35 with OPC cement 390.00 Kgs
KSRRB M2200-5.20: Design mix M35 with OPC cement 390.00 Kgs
PCC grade M15 with OPC cement 240.00 Kgs
PCC grade M20 with OPC cement 300.00 Kgs
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete
M20 320.00 Kgs
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in
320.00 Kgs
super
KSRRBstructure -M20
M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in
super structure -M20 320.00 Kgs
KSRRB M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in 320.00 Kgs
super structure -M20
KSRRB M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in 320.00 Kgs
super
KSRRBstructure -M20
M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in 320.00 Kgs
super structure -M20
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete
in superM2300-2.1:
structure -Furnishing
M20 320.00 Kgs
KSRRB and placing reinforced/Prestressed cement concrete
in super structure - M20 320.00 Kgs
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete 320.00 Kgs
in super structure - M20
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete 320.00 Kgs
in super structure - M20
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete 320.00 Kgs
in superM2300-2.2:
KSRRB structure -Furnishing
M20 and placing reinforced/prestrssed cement concrete in 320.00 Kgs
super structure as per drawing
KSRRB M2300-2.2: Furnishing and andplacing
technical specifcations - M20cement concrete in
reinforced/prestrssed
super 320.00 Kgs
KSRRBstructure as per
M2300-2.2: drawingand
Furnishing andplacing
technical specifcations - M20cement concrete in
reinforced/prestrssed
super structure as per drawing and technical specifcations - M20 320.00 Kgs
KSRRB M2300-2.2: Furnishing and placing reinforced/prestrssed cement concrete in 320.00 Kgs
super structure as per drawing and technical specifcations - M20
KSRRB M2300-2.2: Furnishing and placing reinforced/prestrssed cement concrete in 320.00 Kgs
super structure as per drawing and technical specifcations - M20
KSRRB M2300-3.1 : Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-3.1
KSRRB structure -: M25
Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-3.1 : Furnishing and placing reinforced/ prestressed cement concrete
in superM2300-3.1
structure -: M25 340.00 Kgs
KSRRB Furnishing and placing reinforced/ prestressed cement concrete
in super structure - M25 340.00 Kgs
KSRRB M2300-3.1 : Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-3.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-3.2:
KSRRB structure as per drawing
Furnishing and-placing
M25 reinforced/ prestressed cement concrete
340.00 Kgs
in superM2300-3.2:
KSRRB structure as per drawing
Furnishing and-placing
M25 reinforced/ prestressed cement concrete
in super structure as per drawing - M25 340.00 Kgs
KSRRB M2300-3.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure as per drawing - M25
KSRRB M2300-3.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-4.1:
KSRRB structure as per drawing
Furnishing and-Placing
M25 reinforced/ prestressed cement concrete
340.00 Kgs
in superM2300-4.1:
KSRRB structure -Furnishing
M25 and Placing reinforced/ prestressed cement concrete
in super structure - M25 340.00 Kgs
KSRRB M2300-4.1: Furnishing and Placing reinforced/ prestressed cement concrete
in super structure - M25 340.00 Kgs
KSRRB M2300-4.1: Furnishing and Placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-4.1: Furnishing and Placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-4.2: Furnishing and placing reinforced/ prestressed cement concrete
in super structure M25 340.00 Kgs
KSRRB M2300-4.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure M25
KSRRB M2300-4.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-4.2:
KSRRB structure M25
Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-4.2:
KSRRB structure M25
Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure M25
KSRRB M2300-5.1: Furnishing and Placing reinforced/ prestressed cement concrete
in superM2300-5.1:
structure -Furnishing
M30 360.00 Kgs
KSRRB and Placing reinforced/ prestressed cement concrete
in super structure - M30 360.00 Kgs
KSRRB M2300-5.1: Furnishing and Placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.1: Furnishing and Placing reinforced/ prestressed cement concrete 360.00 Kgs
in superM2300-5.1:
KSRRB structure -Furnishing
M30 and Placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.2: Furnishing and placing reinforced / prestressed cement concrete 360.00 Kgs
in superM2300-5.2:
KSRRB structure -Furnishing
M30 and placing reinforced / prestressed cement concrete
in super structure - M30 360.00 Kgs
KSRRB M2300-5.2: Furnishing and placing reinforced / prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.2: Furnishing and placing reinforced / prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.2: Furnishing and placing reinforced / prestressed cement concrete 360.00 Kgs
in superM2300-6.1:
KSRRB structure -Furnishing
M30 and placing Reinforced/ Prestressed cement concrete
360.00 Kgs
in
KSRRB M2300-6.1: Furnishing andM30
super structure as per drawing placing Reinforced/ Prestressed cement concrete
in super structure as per drawing M30 360.00 Kgs
KSRRB M2300-6.1: Furnishing and placing Reinforced/ Prestressed cement concrete 360.00 Kgs
in super structure as per drawing M30
KSRRB M2300-6.1: Furnishing and placing Reinforced/ Prestressed cement concrete 360.00 Kgs
in superM2300-6.1:
KSRRB structure as per drawing
Furnishing andM30
placing Reinforced/ Prestressed cement concrete 360.00 Kgs
in super structure as per drawing M30
KSRRB M2300-6.2: Furnishing and placing reinforced/ prestressed cement concrete
in superM2300-6.2:
structure -Furnishing
M30 360.00 Kgs
KSRRB and placing reinforced/ prestressed cement concrete
in super structure - M30 360.00 Kgs
KSRRB M2300-6.2: Furnishing and placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-6.2: Furnishing and placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-6.2: Furnishing and placing reinforced/ prestressed cement concrete 360.00 Kgs
in superM230-7.1:
KSRRB structure Furnishing
- M30 and placing Reinforced/ prestressed cement concrete 390.00 Kgs
in super structure as per drawing - M35 Reinforced/ prestressed cement concrete
KSRRB M230-7.1: Furnishing and placing
in superM230-7.1:
structure Furnishing
as per drawing - M35 Reinforced/ prestressed cement concrete 390.00 Kgs
KSRRB and placing
in super structure as per drawing - M35 390.00 Kgs
KSRRB M230-7.1: Furnishing and placing Reinforced/ prestressed cement concrete 390.00 Kgs
in super structure as per drawing - M35
KSRRB M230-7.1: Furnishing and placing Reinforced/ prestressed cement concrete 390.00 Kgs
in super structure as per drawing - M35
KSRRB M2300-7.2: Furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in superM2300-7.2:
KSRRB structure M35
Furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in super structure M35
KSRRB M2300-7.2: Furnishing and placing reinforced/ prestressed cement concrete
in superM2300-7.2:
structure M35 390.00 Kgs
KSRRB Furnishing and placing reinforced/ prestressed cement concrete
in super structure M35 390.00 Kgs
KSRRB M2300-7.2: Furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in super structure M35
KSRRB M2300-7.3: Furnishing and Placing Reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-7.3:
KSRRB structure -Furnishing
M35 and Placing Reinforced/ Prestressed cement concrete
390.00 Kgs
in superM2300-7.3:
KSRRB structure -Furnishing
M35 and Placing Reinforced/ Prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-7.3: Furnishing and Placing Reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-7.3: Furnishing and Placing Reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-8.1:
KSRRB structure -Furniture
M35 and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.1: Furniture and placing reinforced/ Prestressed cement concrete
in superM2300-8.1:
structure -Furniture
M35 390.00 Kgs
KSRRB and placing reinforced/ Prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-8.1: Furniture and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.1: Furniture and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.2: Furnishing and placing reinforced/ Prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-8.2: Furnishing and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.2: Furnishing and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-8.2:
KSRRB structure -Furnishing
M35 and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-8.2:
KSRRB structure -Furnishing
M35 and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.3: furnishing and placing reinforced/ prestressed cement concrete
in superM2300-8.3:
structure -furnishing
M35 390.00 Kgs
KSRRB and placing reinforced/ prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-8.3: furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.3: furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in superM2300-8.3:
KSRRB structure -furnishing
M35 and placing reinforced/ prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-9.1: Furnishing and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in superM2300-9.1:
KSRRB structure M40
Furnishing and placing reinforced/ Prestressed cement concrete
in super structure M40 420.00 Kgs
KSRRB M2300-9.1: Furnishing and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M2300-9.1: Furnishing and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M2300-9.1: Furnishing and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in superM2300-9.2:
KSRRB structure M40
Furnishing and placing reinforced/ prestressed cement concrete
420.00 Kgs
in super structure as per drawing
KSRRB M2300-9.2: Furnishing andM40
placing reinforced/ prestressed cement concrete
in super structure as per drawing M40 420.00 Kgs
KSRRB M2300-9.2: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in super structure as per drawing M40
KSRRB M2300-9.2: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in superM2300-9.2:
KSRRB structure as per drawing
Furnishing andM40
placing reinforced/ prestressed cement concrete 420.00 Kgs
in super structure as per drawing M40
KSRRB M2300-10.1: Furnishing and placing reinforced/ prestressed cement
concrete in super structure as per 420.00 Kgs
KSRRB M2300-10.1: Furnishing anddrawing
placing M40
reinforced/ prestressed cement
concrete in super structure as per drawing M40 420.00 Kgs
KSRRB M2300-10.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure as per drawing M40
KSRRB M2300-10.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure as per drawing M40
KSRRB M2300-10.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure
KSRRB M2300-10.2: as per
Furnishing anddrawing
placing M40
reinforced/ prestressed cement 420.00 Kgs
concrete in super structure M40
KSRRB M2300-10.2: Furnishing and placing reinforced/ prestressed cement
concrete in super structure M40and placing reinforced/ prestressed cement 420.00 Kgs
KSRRB M2300-10.2: Furnishing
concrete in super structure M40 420.00 Kgs
KSRRB M2300-10.2: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure M40
KSRRB M2300-10.2: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure M40
KSRRB M230-10.3: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in superM230-10.3:
KSRRB structure M40
Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M230-10.3: Furnishing and placing reinforced/ prestressed cement concrete
in superM230-10.3:
structure M40 420.00 Kgs
KSRRB Furnishing and placing reinforced/ prestressed cement concrete
in super structure M40 420.00 Kgs
KSRRB M230-10.3: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M2300-11.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure
KSRRB M2300-11.1: as per
Furnishing anddrawing
placing M40
reinforced/ prestressed cement
420.00 Kgs
concrete in super structure
KSRRB M2300-11.1: as per
Furnishing anddrawing
placing M40
reinforced/ prestressed cement
concrete in super structure as per drawing M40 420.00 Kgs
KSRRB M2300-11.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure as per drawing M40
KSRRB M2300-11.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure
KSRRB M2300-11.2: as per
Furnishing anddrawing
placing M40
reinforced/ Prestressed cement 440.00 Kgs
concrete in super structrure as per drawing M45
KSRRB M2300-11.2: Furnishing and placing reinforced/ Prestressed cement
concrete in super structrure as per drawing M45 440.00 Kgs
KSRRB M2300-11.2: Furnishing and placing reinforced/ Prestressed cement
concrete in super structrure as per drawing M45 440.00 Kgs
KSRRB M2300-11.2: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structrure as per drawing M45
KSRRB M2300-11.2: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structrure as per drawing M45
KSRRB M2300-11.3: Furnishing and placing reinforced/ Prestressed cement
concrete in super structure M45 440.00 Kgs
KSRRB M2300-11.3: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structure M45
KSRRB M2300-11.3: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structure
KSRRB M2300-11.3: M45and placing reinforced/ Prestressed cement
Furnishing 440.00 Kgs
concrete in super structure
KSRRB M2300-11.3: M45and placing reinforced/ Prestressed cement
Furnishing 440.00 Kgs
concrete in super structure
KSRRB M2300-12: Furnishing M45
and placing reinforced/ Prestressed cement concrete
in 450.00 Kgs
KSRRB M2300-12: Furnishing and M50
super structure as per drawing placing reinforced/ Prestressed cement concrete
in super structure as per drawing M50 450.00 Kgs
KSRRB M2300-12: Furnishing and placing reinforced/ Prestressed cement concrete 450.00 Kgs
in super structure as per drawing M50
KSRRB M2300-12: Furnishing and placing reinforced/ Prestressed cement concrete 450.00 Kgs
in superM2300-12:
KSRRB structure as per drawing
Furnishing and M50
placing reinforced/ Prestressed cement concrete 450.00 Kgs
in super structure as per drawing M50
KSRRB M2300-13: Furnishing and placing reinforced/ prestressed cement concrete 450.00 Kgs
in superM2300-13:
KSRRB structure M55
Furnishing and placing reinforced/ prestressed cement concrete
in super structure M55 450.00 Kgs
KSRRB M2300-13: Furnishing and placing reinforced/ prestressed cement concrete 450.00 Kgs
in super structure M55
KSRRB M2300-13: Furnishing and placing reinforced/ prestressed cement concrete 450.00 Kgs
in super structure M55
KSRRB M2300-13: Furnishing and placing reinforced/ prestressed cement concrete 450.00 Kgs
in super2300-16:
KSRRB structure M55 and laying cement concrete wearing coat with OPC
Providing
360.00 Kgs
cement
KSRRB design mix
M2500-2: M30 and laying of apron with cement concrete blocks of size
Providing
KSRRB M2500-4.2:
0.5x0.5x0.5m M15 providing and laying pitching on slopes laid over prepared filter 240.00 Kgs
media including boulder apron laid dry in front of toe of embankment complete as 240.00 Kgs
per drawing and technical specifications -do- B. Cement concrete Blocks of size
KSRRB M2500-5.1:
0.3x0.3x0.3m Providing
cast in and layingofFlooring
cement concrete complete as per drawing and
grade M-15 168.30 Kgs
technical specifications
KSRRB M2700-6: PCC M15 laidgrade
over A. Rubblecourse
leveling stonebelow
laid in approach
cement mortar 1:3
slab complete as 240.00 Kgs
per drawing and technical specification complete as per specifications
KSRRB M2700-7: Reinforced cement concrete M30 approach slab 360.00 Kgs
KSRRB M2900-1: Plain cement concrete 1:3:6 mix with crushed 220.00 Kgs
KSRRb M300-6: Filling of crack using slow - curing bitumen emulsion and applying 0.066 Kgs
crusher dust in case crack are wider
KSRRB M2500-9 Curtain wall complete as per drawing and technical specifications. 153.00 Kgs
A stone masonry in cement mortar (1:3)
KSRRB M2500-10 Curtain wall complete as per drawing and Technical Specifications. 240.00 Kgs
B. Cement concrete Grade M-15
Repairs to Building 0.002 EACH
Repairs to Building 0.002 EACH
Repairs to Building 0.002 EACH
Repairs to Building 0.005 EACH
Repairs to Building 0.005 EACH
Repairs to Building 0.005 EACH
Repairs to Building 0.200 EACH
Repairs to Building 4.000 EACH
Repairs to Building 0.120 cum
Repairs to Building 0.120 cum
Repairs to Building 0.120 cum
Repairs to Building 0.00010 Metre.
Repairs to Building 0.00010 Metre.
KSRB 4.9.2: Providing T.M.T. steel reinforcement for RCC work 0.10750 Tonne
KSRB 4.9.2: Providing T.M.T. steel reinforcement for RCC work 0.10750 Tonne
KSRRB M1100-5: Driven vertical steel piles as per drawing = pile 400x250mm (ISHB 8.62800 Tonne
series)
KSRRB M1100-6: Driven vertical steel piles as per drawing = H section steel column
450x250mm (ISHB Series) 0.09716 Tonne
KSRRB M1100-13. Supplying, fitting and placing uncoated TMT bar reinforcement 1.050 Tonne
KSRRB M1100-13. Supplying, fitting and placing uncoated TMT bar reinforcement 1.050 Tonne
KSRRB M1100-14: Supplying, fitting and placing un-coated Mild steel reinforcement 1.050 Tonne
in foundation as per drawing
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m -Providing and fixing -
do- LWL in open foundation upto 3m 0.01150 Tonne
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m - do- below LWL in 0.01150 Tonne
open foundation beyond 3m
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m -do- for well 0.01150 Tonne
foundation below
Providing and LWL
fixing 3mupto
long 3m
25mm dia TMT dowel bars 1.5m -do- for well 0.01150 Tonne
foundation belowSupplying,
KSRRB M2200-6: LWL beyond 3m and placin
fitting 1.050 Tonne
TMT
KSRRB bar
M2200-6: Supplying, fitting and placin
TMT bar 1.050 Tonne
KSRRB M2200.7: Supplying, fitting and placing mild steel 1.050 Tonne
KSRRB M2300-14: Supplying, fitting and placing TMT bar reinforcement in super 1.050 Tonne
structure complete
KSRRB M2300-14: Supplying, fitting and placing TMT bar reinforcement in super 1.050 Tonne
structure complete
KSRRB M2300-15: High tensile steel wires/ strands including all accessories 1.020 Tonne
KSRRB M2700-2. Construction of precast RCC 0.01892 Tonne
railing of M-30 grade
21.7 0.00025 MT
21.9 0.00040 MT
21.10.2 0.00020 MT
21.11.1 0.068 MT
21.11.3 0.068 MT
21.11.5 0.068 MT
21.11.2 0.072 MT
21.11.4 0.072 MT
21.11.6 0.072 MT
21.12 0.003 MT
21.17.1 0.092 MT
21.17.3 0.092 MT
21.17.5 0.092 MT
21.17.2 0.103 MT
21.17.4 0.103 MT
21.17.6 0.103 MT
21.20.1 0.103 MT
21.20.3 0.103 MT
21.20.5 0.103 MT
21.20.7 0.103 MT
21.20.9 0.103 MT
21.20.11 0.103 MT
21.20.2 0.115 MT
21.20.4 0.115 MT
21.20.6 0.115 MT
21.20.8 0.115 MT
21.20.10 0.115 MT
21.20.12 0.115 MT
21.21.1 0.103 MT
21.21.3 0.103 MT
21.21.5 0.103 MT
21.21.7 0.103 MT
21.21.9 0.103 MT
21.21.11 0.103 MT
21.21.2 0.115 MT
21.21.4 0.115 MT
21.21.6 0.115 MT
21.21.8 0.115 MT
21.21.10 0.115 MT
21.21.12 0.115 MT
21.22.1 0.129 MT
21.22.3 0.129 MT
21.22.5 0.129 MT
21.22.2 0.141 MT
21.22.4 0.141 MT
21.22.6 0.141 MT
21.23.1 0.117 MT
21.23.3 0.117 MT
21.23.5 0.129 MT
21.23.7 0.129 MT
21.23.9 0.129 MT
21.23.11 0.129 MT
21.23.2 0.141 MT
21.23.4 0.141 MT
21.23.6 0.141 MT
21.23.8 0.141 MT
21.23.10 0.141 MT
21.23.12 0.141 MT
21.26 0.0012 MT
21.27 0.0010 MT
21.32 0.00146 MT
21.33 0.00146 MT
21.36 0.0022 MT
21.37 0.0022 MT
21.38 0.0019 MT
21.39 0.0019 MT
21.40 0.0022 MT
21.41 0.0022 MT
21.42 0.0019 MT
21.43 0.0019 MT
21.45.1 0.00098 MT
21.45.2 0.00068 MT
21.47 0.00582 MT
21.64 0.00121 MT
21.65 0.000858 MT
21.66 0.000527 MT
21.67 0.0009 MT
21.68 0.0011 MT
21.69 0.0015 MT
21.70 0.00105 MT
21.74.1 0.081 MT
21.74.2 0.081 MT
21.74.3 0.054 MT
21.74.4 0.054 MT
21.77.1 0.0955 MT
21.77.1 Waste Plastic 8.31 Kg
21.77.2 0.106 MT
21.77.2 9.23 Kg
21.78.1 0.119 MT
21.78.1 10.37 Kg
21.78.2 0.130 MT
21.78.2 11.31 Kg
21.79.1 0.136 MT
21.79.1 7.07 Kg
21.79.2 0.136 MT
21.79.2 7.07 Kg
KSRRB M2700-1: Providing and laying 12mm thick mastic asphalt wearing course on 0.00283 MT
top of deck slab
KSRRB M2800-2: Removal of existing asphaltic wearing coat comprising 0.0160 MT
KSRRB M2800-5.1: Sealing of cracks/porous concrete by injection 0.0011 MT
KSRRB 3000 Filling Potholes and Patch repairs with open graded premix surfacing,
20mm KSRRB M300-4 0.00146 MT
KSRRB 3000 Filling pot holes and patch repairs with Bituminous concrete 40mm 0.00459 MT
KSRRB M2100-8. Filling Annular Space Around Footing in Rock Lean cement 0.00024 MT
concrete
KSRRB M2700-2.
1:3:6 nominal
Construction
mix of precast RCC
railing of M-30 grade 0.03069 MT
21.5 0.0011 MT
21.6 0.0006 MT
21.55 0.1756 MT
21.56 0.1756 MT
21.70 0.0987 MT
21.71 0.153 MT
21.72 0.1865 MT
KSRRB 3000 Filling Potholes and Patch repairs with open graded premix surfacing, 0.00024 MT
20mm KSRRB M300-4
KSRRB 3000 Filling pot holes and patch repairs with Bituminous concrete 40mm 0.00024 MT
Linolium sheet 1.05 sqm, 1.05 Sqm
adhesive 0.20 kg 0.20 kgs
Metallic floor hardner 2.6 kg 2.60 kgs
Metallic floor hardner 2.6 kg 2.60 kgs
Shahabad slab 1.15 sqm, 1.15 Sqm
pigment 0.45 kg 0.45 kgs
pigment 0.45 kg 0.45 kgs
marble chips 17.3 kgs, 17.30 kgs
marble powder 0.0017 cum 0.0017 cum
pigment 0.56 kgs 0.56 kgs
marble chips - 17.3 kgs, 17.30 kgs
marble powder - 0.0017 cum, 0.0017 cum
white cement - 0.16 kgs, pigment 0.16 Kgs
Marble chips - 17.3 kgs, 17.30 Kgs
white cement 0.08 bags, 4.00 kgs
marble powder - 0.0017 cum, pigment 0.0017 cum
Marble chips - 17.3 kgs, 17.30 kgs
white cement 0.16 bags, 8.00 Kgs
marble powder - 0.0017 cum, pigment 0.0017 cum
Alluminium sheet for strips - 0.042 sqm 0.042 Sqm
Glass strips - 0.044 sqm 0.044 Sqm
mosaic tiles - 1.1 sqm, 1.10 Sqm
pigment 0.30 kgs 0.30 Sqm
white cement - 0.08 bags, 4.00 kgs
pigment - 0.30 kgs 0.30 Kgs
mosaic tiles - 1.1 sqm, 1.10 Sqm
white cement - 0.04 bags, 2.00 kgs
pigment - 0.30 kgs 0.30 kgs
white mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.17 bags 8.50 Kgs
checkered mosaic tiles - 1.10 sqm, 1.10 Sqm
pigment - 0.3 kgs 0.30 kgs
checkered mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.088 bags, 4.40 Kgs
pigment - 0.3 kgs 0.30 Kgs
mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.04 bags, 2.00 kgs
pigment - 0.30 kgs 0.30 kgs
mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement -0.17 bags 8.50 kgs
ceramic tiles - 1.10 sqm, 1.10 Sqm
ceramic tiles - 1.10 sqm, 1.10 Sqm
ceramic tiles - 1.10 sqm, 1.10 Sqm
ceramic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.002 bags 0.10 Kgs
white cement - 0.002 bags 0.10 Kgs
white cement - 0.002 bags 0.10 Kgs
white cement - 0.002 bags 0.10 Kgs
marble slabs - 1.15 sqm, 1.15 Sqm
white cement - 0.01 bags 0.50 Kgs
red oxide - 0.28 kg 0.28 kgs
glazed tiles - 46 nos. 46.00 Nos
Glazed tiles 46 nos. 46.00 Nos
Glazed tiles 46 nos. 46.00 Nos
Glazed tiles 46 nos. 46.00 Nos
marble slab - 1.15 sqm 1.15 Sqm
Water proof compound - 0.13 kgs 0.13 kgs
Water proof compound - 0.09 kgs 0.09 kgs
Water proof compound - 0.125 kgs 0.125 kgs
Water proof compound - 0.15 kgs 0.15 kgs
Water proof compound - 0.167 kgs 0.167 kgs
Water proof compound - 0.22 kgs 0.22 Kgs
Water proof compound - 0.167 kgs 0.167 Kgs
Lime - 0.0025/cum 0.0025 cum
burnt lime - 0.003 quintal 0.0030 Qtl
Burnt lime - 0.0015 quintal 0.0015 Qtl
Burnt lime - 0.003 quintal 0.003 Qtl
Burnt lime - 0.015 quintal 0.015 Qtl
Linseed oil 0.08 ltr. 0.08 ltr
Gopi - 0.025 kg, 0.025 kgs
Burnt lime 0.0015, 0.0015 Sqm
Gopi - 0.013 0.013 Kgs
Distemper - 0.081 ltr 0.081 ltr
Dry distemper - 0.1 kg, 0.10 kgs
whitening - 0.1 kg 0.10 Kgs
Dry distemper - 0.06 kg 0.06 kgs
Dry distemper - 0.04 kg 0.04 kgs
Distemper - 0.081 ltr, 0.081 ltr
oil bound - 0.15 kg 0.15 Kg
Oil bound - 0.1 kg 0.10 kg
Plastic emulsion paint - 0.12 ltr 0.12 ltr
Plastic emulsion paint - 0.073 ltr 0.073 ltr
Plastic emulsion paint - 0.049 ltr 0.049 ltr
Water proof cement paint - 0.3 kg 0.30 kg
Water proof cement paint - 0.18 kg 0.18 kg
Water proof cement paint - 0.12 kg 0.12 kg
White lead paint - 0.1 ltr 0.10 ltr
Pink Primer paint - 0.09 ltr 0.09 ltr
Aluminium paint primer - 0.1 ltr 0.10 ltr
Enamel primer - 0.09 ltr 0.09 ltr
Liquid wood filler - 0.075 ltr 0.075 ltr
Enamel metal paint - 0.15 ltr 0.15 ltr
Enamel metal paint - 0.15 ltr 0.15 ltr
Enamel metal paint - 0.09 ltr 0.09 ltr
Enamel metal paint - 0.09 ltr 0.09 ltr
Under coat flatting varnish - 0.07 ltr., 0.07 ltr
Varnish - 0.075 ltr 0.075 ltr
Varnish - 0.075 ltr 0.075 ltr
Varnish - 0.075 ltr 0.075 ltr
Spirit - 0.16 ltr, 0.16 ltr
Shellac - 0.024 kg, 0.024 kg
Linseed oil - 0.012 ltr, 0.012 ltr
pigment - 0.012 kg 0.012 kg
Spirit - 0.095 ltr, 0.095 ltr
Shellac - 0.013 kg, 0.013 Kg
Linseed oil - 0.007 ltr., 0.007 ltr
Bees wax - 0.05 kg, 0.05 Kg
Linseed oil - 0.036 ltr., 0.036 ltr
Varnish - 0.012 ltr 0.012 ltr
Bees wax - 0.25 kg, 0.25 kg
Linseed oil - 0.018 ltr., 0.018 ltr
Varnish - 0.06 ltr 0.06 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Ready mix primer paint - 0.09 ltr 0.09 ltr
Enamel metal paint - 0.15 ltr 0.15 ltr
Enamel metal paint - 0.09 ltr 0.09 ltr
Alluminium paint - 0.08 ltr 0.08 ltr
Alluminium paint - 0.046 ltr 0.046 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Ready mix primer paint - 0.084 ltr., 0.084 ltr
plaster of paris - 0.05 kg 0.05 kg
Wall paint - 0.11 ltr., 0.11 ltr
Wall paint - 0.65 ltr., 0.65 ltr
Ready mix primer paint - 0.148 ltr., 0.148 ltr
Ready mix primer paint - 0.09 ltr., 0.09 ltr
Wax polish - 0.01 kg 0.01 kg
Wax polish - 0.007 kgs 0.007 kgs
Marble chips - 0.87 kgs, 0.87 kgs
marble powder - 0.0007 cum, 0.0007 cum
pigment - 0.285 kgs 0.285 kgs
White cement - 0.41 kg, 0.41 kg
Marble chips - 0.87 kgs, 0.87 kgs
Marble powder - 0.0007 cum, 0.0007 cum
pigment - 0.285 kgs 0.285 kgs
White cement - 0.04 bags, 2.00 kgs
Marble chips - 8.7 kgs, 8.70 kgs
Marble powder - 0.0007 cum, 0.0007 cum
pigment - 0.28 kgs 0.28 kgs
White cement - 0.08 bags, 4.00 kgs
Marble chips - 8.7 kgs, 8.70 kgs
Marble powder - 0.0007 cum 0.0007 cum
Mosaic tiles - 1.10 Sqm 1.10 Sqm
Mosaic tiles - 1.10 Sqm, 1.10 Sqm
pigment 0.462 kgs 0.462 kgs
Mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.066 bags, 3.30 Kgs
pigment 0.55 kgs 0.55 kgs
Mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.13 bags 6.50 Kgs
Nitric acid - 0.01 ltr / sqm 0.01 ltr
paint remover - 0.07 ltr/sqm, blow, lamp, brushes, 0.07 ltr
caustic soda - 0.073 kg/sqm, scraper, brushes, 0.073 kg
Kerosene oil - 0.10 ltr/sqm, scraper, putty at 5% on cost of kerosene oil 0.10 ltr
Kerosene oil - 0.10 ltr/sqm, scraper, putty at 5% on cost of kerosene oil 0.10 ltr
Paint remover - 0.07 ltr/sqm, brushes, scraper,terpentine oil, putty at 2% on 0.07 ltr
paint removal cost
Putty for filling holes-0.068 kg/metre 0.068 kg
Sl. Code Hire Charges Component Name
No. No.
1 1001 Mixer (concrete) - 1 cum Capacity
2 1002 Vibrator (with needle)
3 1004 Bitumen Boiler Oil Fired - 1500 ltr. Capacity
4 1005 Mini Mix Plant 6/10 TPH
5 1006 Wheel Burrows
6 1007 Hand Mixer
7 1008 Farm Tractor
8 1010 Mechanical Paver finisher 100 TPH capacity
9 1011 Tipper
10 1012 Front End Loader 1 cum bucket capacity
11 1013 Hot Mix Plant 40/60 TPH
12 1014 Vibrator Roller
13 1015 Hire charges for Tractor mounted or mini dozer
14 1016 Pneumatic Tyre Roller (8 Tonnes) - 25 cum / hr
15 1018 Motor Grader BEML
16 1019 Motorised scrapper
17 1020 Wheeled Dozer D 50 BEML
18 1022 Hydraulic Control Paver finisher (with Electronic S
19 1023 Tractor 40 HP
20 1024 Tractor 50 HP
21 1028 Wet Mix Plant 60 TPH/ Pug Mill
22 1030 Air Compressor
23 1031 J.C.B. Excavator
24 1032 Water Tanker / Day
25 1035 Road Roller 8-10 T ( 425Cum/day soil compacted)
Front end loader (1Cum) Turnover 120 Cum /day
26 1036 when used with hot mix plant
27 1037 Vibratory Roller 8 Tonne
28 1038 Pneumatic Road Roller
29 1039 Tandem Road Roller - 30 cum / hr
30 1040 Motor Grader 3.35 meter blade
31 1041 Motorised scraper (950 Cum / day)
32 1042 Wheeled Dozer (D50 BEML)
33 1043 Hot mix Plant ( 6-10TPH) 8T /hr capacity
34 1045 Hot mix plant 40-60 TPH Capacity
35 1046 Paver finisher Mechanical 100 TPH capacity
36 1047 Paver Finisher Hydrostatic with sensor control 100
37 1048 Tractor 40 HP
38 1049 Tractor 50 HP
39 1055 Air compressor (170 Cfm)
40 1056 Hydraulic Excavator 1 cum bucket
41 1057 Water Tanker
42 1058 Tractor mounted dozer
43 1059 Mixer (concrete small used in culvert)
44 1060 Vibrator
45 1063 Concrete pump 45 & 30 cum capacity
46 1064 nsit mixer 4.5 cum/hour
47 1065 Batching Plant (30 cum/hour)
48 1066 Batching Plant (15- 20 cum/hour)
49 1069 HOM for pumping water 3.5 KL / hr capacity pump
50 1070 HOM of Vibrator
51 1071 HOM of welding and grinding machine
52 1073 HOM of cutting and grinding machine
53 1074 HOM of cutting and grinding machine
54 1075 HOM of Machinaries for planing
55 1076 HOM of polishing machine
56 1077 HOM of Blow lamp
57 1078 HOM of pilling rig with Bentonite pump, etc.
58 1079 HOM of pump 23 KW
59 1080 HOM of pump 9.5 KW
60 1081 HOM of pneumatic hammer and pavement braker
61 1082 HOM of screed vibrator
62 1083 Mastic cooker
63 1084 HOM of gunniting equipment
64 1085 HOM of drilling equipment
65 1086 Plate vibrator having 3 Ton compaction force
66 1087 Crane charges
67 1088 Grout pump, agitator
68 1089 HOM of 7.5 cft capacity concrete mixing machine
69 1092 Crane Charges
70 1093 HOM of Machinery jack for prestressing
71 1094 HOM of spraying machine
72 1095 Crawlar Tractor
73 1096 Tipper-5 cum
74 1097 Smooth Wheeled Roller
75 1098 Rotavator - 25 cum / hr
76 1099 Ripper - 60 cum / hr
77 1301 Mechanical Broom Hydraulic
78 1302 Bitumen Pressure Distributor
79 1303 Emulsion Pressure Distrbutor
80 1304 Hotmix Plant - 120 TPH capacity
81 1305 Hotmix Plant - 100 TPH capacity
82 1306 Vacuum dewatering
83 1307 Hydraulic Chip Spreader
84 1308 Pot-hole Repair Machine
85 1309 GSB Plant 50 cum
86 1311 Cranes 80 tonnes
87 1312 Cranes 35 tonnes
88 1313 Cranes 3 tonnes
89 1314 Concrete Bucket - 1 cum capacity
90 1315 Kerb Casting Machine
91 1317 Piling Rig with Bantonite Pump
92 1321 Generator 100 KVA
93 1322 Generator 33 KVA
94 1324 Road Marking Machine
95 1325 Mobile Slurry Seal Equipment
96 135 Drilling Equipment (Tractor mounted)
97 1326 Integrated stone crusher of 200 TPH including belt
98 1327 Hot Mix Plant 20 to 40 TPH Capacity
99 1501 Grout pump with agitator & accessories
100 1503 Epoxy Injection gun
101 1506 Shotcreteing equipment
102 1511 Stressing jack with pump
103 1515 Hire charges for jack of 40 tonne lifting capacity
104 1517 Cement concrete batch mix at 75 cum/ hr
105 1527 Road sweeper at 1250 sqm/hr
Cement concrete batch mix at 175 cum/hor
106 1528 (effective output)
107 1529 Electric generator set 250 KVA
108 1530 Slip form paver with electronic sensor
109 1532 Concrete joint cutting machine
Batch type cold mixing plant 100 - 120 TPH
capacity producing an average output of 75 tonne
110 1535 per hour
111 1550 Motorised barge of 20 tonne capacity
112 1551 Boat to carry at least 20 persons
113 902 base mix plant (pug mill)
114 965 Transit mixer 4 cum capacity for lead beyond 1 km
Usage of plant & equipment for pneumatic method
115 970 of well sinking
Air Compressor 250 cfm with pneumatic breaker/
116 996 jack hammer along with accessories
Compressor with guniting equipment along with
117 999 accessories
118 137 Concrete paver finisher with 40 HP Motor
Unit Rate
RS. PS.
Day 1,600.00
Day 350.00
hr 157.00
Day 1,600.00
Day 15.00
Day 160.00
Day 2,260.00
Day 7,040.00
Day 2,016.00
hr 700
Day 76,960.00
Day 11,560.00
Day 2,400.00
Day 8,272.00
Day 15,200.00
Day 1,520.00
Day 14,000.00
Day 18,560.00
Day 1,520.00
Day 2,512.00
hr 1,133.00
Day 2,304.00
Day 6,720.00
Day 485.60
hr 433.00

hr 700.00
hr 1,300.00
hr 1,034.00
hr 1,034.00
hr 2,080.00
hr 190.00
hr 1,600.00
hr 375.00
hr 9,620.00
hr 880.00
hr 2,320.00
hr 190.00
hr 314.00
hr 290.00
hr 1,130.00
hr 61.00
hr 375.00
hr 50.00
hr 50.00
hr 194.00
hr 740.00
hr 1,850.00
hr 1,548.00
hr 50.00
Day 200.00
Day 400.0
Day 400.0
hr 50.00
cum 40.00
Day 200.00
Day 50.00
Day 37,960.00
Day 800.00
Day 500.00
hr 50.00
hr 50.00
Day 448.00
Day 400.00
Day 50.00
Day 300.00
Day 4,000.00
Day 300.00
Day 1,440.00
hr 500.00
hr 91.00
Day 75.00
hr 200.00
hr 240.00
hr 386.00
hr 14.55
hr 24.65
hr 309.00
hr 890.00
hr 665.00
hr 18,600.00
hr 13,750.00
Sq.mtr 40.00
hr 2,000.00
hr 852.00
hr 902.00
hr 971.00
hr 647.00
hr 270.00
hr 12.30
hr 280.00
hr 4,745.00
hr 630.00
hr 296.00
hr 67.30
hr 802
Day 1,920.00
hr 13,150.00
hr 4,580.00
hr 800.00
hr 275.00
hr 100.00
hr 150.00
No. 3,300.00
hr 1,800.00
hr 276.00

hr 7,904.00
hr 750.00
hr 1,800.00
hr 1,565.00

hr 8,000.00
hr 500.00
hr 110.00
hr 1,133.00
t.km 2.00

hr 400.00

hr 257.00

hr 257.00
hr 2,170.00