You are on page 1of 350

SCHEDULE OF RATES 2016-2017 PW, P & IWTD, SOUTH ZONE BANGALORE

SL NO Name Unit Rate

1.0 MORTAR

1.1 KSRB 0.5-1.1 : Providing cement mortar of mix 1:1 (1 cement :1 sand) including cost of
all materials, labour charges, HOM ofmachinery complete as per specifications.Specification Cum 10708.00
No. KBS 0.5-1.2
1.2 KSRB 0.5-1.2 : Providing cement mortar of mix 1:2(1 cement :2 sand) including cost of
all materials, labour charges, HOM ofmachinery complete as per specifications. Cum 8232.00
Specification No. KBS 0.5-1.2
1.3 KSRB 0.5-1.3 : Providing cement mortar of mix 1:3 (1 cement : 3 sand) including cost of
all materials, labour charges, HOM of machinery complete as per specifications. Cum 6996.00
Specification No. KBS 0.5-1.2
1.4 KSRB 0.5-1.4 : Providing cement mortar of mix 1:4 (1 cement :4 sand) including cost of
all materials, labour charges, HOM ofmachinery complete as per specifications. Cum 5861.00
Specification No. KBS 0.5-1.2
1.5 KSRB 0.5-1.5 : Providing cement mortar of mix 1:5 (1 cement :5 sand) including cost of
all materials, labour charges, HOM of machinery complete as per specifications. Cum 5250.00
Specification No. KBS 0.5-1.2
1.6 KSRB 0.5-1.6 : Providing cement mortar of mix 1:6 (1 cement :6 sand) including cost of
all materials, labour charges, HOM of machinery complete as per specifications. Cum 4727.00
Specification No. KBS 0.5-1.2
1.7 KSRB 0.5-1.7 : Providing cement mortar of mix 1:8 (1 cement :8 sand) including cost of
all materials, labour charges, HOM ofmachinery complete as per specifications. Cum 4203.00
Specification No. KBS 0.5-1.2
1.8 KSRB 0.5-1.8 : Providing cement mortar of mix 1:10 (1 cement :10 sand) including cost
of all materials, labour charges, HOM of machinery complete as per specifications. Cum 3854.00
Specification No. KBS 0.5-1.2
1.9 KSRB 0.5-2.1 : Providing lime mortar of mix 1:1 (1 lime putty :1 sand) including cost of
all materials, labour charges, HOM of machinery complete as per specifications. Cum 5715.00
Specification No. KBS 0.5-2.1
1.10 KSRB 0.5-2.2 : Providing lime mortar of mix 1:2 (1 lime putty :2 sand) including cost of
all materials, labour charges, HOM of machinery complete as per specifications. Cum 5020.00
Specification No. KBS 0.5-2.1
1.11 KSRB 0.5-2.3 : Providing lime mortar of mix 1:3 (1 lime putty :3 sand) including cost of
all materials, labour charges, HOM of machinery complete as per specifications. Cum 4679.00
Specification No. KBS 0.5-2.1
1.12 KSRB 0.5-3.1 : Providing lime surkhi mortar of mix 1:1 (1 lime putty: 1 surkhi)
including cost of all materials, labour charges, HOM of machinery complete as per Cum 4487.00
specifications. Specification No. KBS
1.13 KSRB 0.5-3.2 : Providing lime surkhi mortar of mix 1:2 (1 lime putty : 2 surkhi)
including cost of all materials, labour charges, HOM of machinery complete as per Cum 3383.00
specifications. Specification No. KBS
1.14 KSRB 0.5-3.3 : Providing lime surkhi mortar of mix 1:3 (1 lime putty :3 surkhi)
including cost of all materials, labour charges, HOM of machinery complete as per Cum 2835.00
specifications. Specification No. KBS
1.15 KSRB 0.5-4.1 : Providing lime surkhi sand mortar of mix 1:1:1 (1 lime putty : 1 surkhi :
1 sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 4143.00
specifications. Specification No. KBS
1.16 KSRB 0.5-4.1 : Providing lime surkhi sand mortar of mix 1:1:2 (1 lime putty : 1 surkhi :
2 sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 3250.00
specifications. Specification No. KBS
1.17 KSRB 0.5-5.1 : Providing cement mortar with stone dust/grit of mix 1:2 (1 cement : 2
stone dust/grit) including cost of all materials, labour charges, HOM of machinery complete Cum 7196.00
as per specifications. Specification No. KBS

Page 1 of 350
Page No. 02
1.18 KSRB 0.5-6.1: Providing cement lime mortar of mix 1:1:3 (1 cement : 1lime putty:3
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 7848.00
specifications. Specification No. KBS 0.5-2.3

1.19 KSRB 0.5-6.2: Providing cement lime mortar of mix 1:1:4 (1 cement : 1lime putty:4
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 7260.00
specifications. Specification No. KBS 0.5-2.3
1.20 KSRB 0.5-6.3: Providing cement lime mortar of mix 1:1:5 (1 cement : 1lime putty:5
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 6862.00
specifications. Specification No. KBS 0.5-2.3
1.21 KSRB 0.5-6.4: Providing cement lime mortar of mix 1:1:6 (1 cement : 1lime putty:6
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 6130.00
specifications. Specification No. KBS 0.5-2.3
1.22 KSRB 0.5-6.5: Providing cement lime mortar of mix 1:1:7 (1 cement : 1lime putty:7
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 5728.00
specifications. Specification No. KBS 0.5-2.3

1.23 KSRB 0.5-6.6: Providing cement lime mortar of mix 1:1:8 (1 cement : 1lime putty:8
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 5356.00
specifications. Specification No. KBS 0.5-2.3

1.24 KSRB 0.5-6.7: Providing cement lime mortar of mix 1:2:9 (1 cement : 2lime putty:9
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 5702.00
specifications. Specification No. KBS 0.5-2.3
1.25 KSRB 0.5-6.8: Providing cement lime mortar of mix 1:3:12 (1 cement : 3lime putty:12
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 5499.00
specifications. Specification No. KBS 0.5-2.3
1.26 KSRB 0.5-7.1 : Providing white cement mortar with marble dust of mix 1:2 (1 white
cement : 2 marble dust) including cost of all materials, labour charges, HOM of machinery Cum 16183.00
complete as per specifications. Specification No. KBS
1.27 KSRB 0.5-7.2 : Providing white cement mortar with marble dust of mix 1:3 (1 white
cement : 3 marble dust) including cost of all materials, labour charges, HOM of machinery Cum 12602.00
complete as per specifications. Specification No. KBS
1.28 KSRB 0.5-7.3 : Providing white cement mortar with marble dust of mix 1:4 (1 white
cement : 4 marble dust) including cost of all materials, labour charges, HOM of machinery Cum 9765.00
complete as per specifications. Specification No. KBS

1.29 KSRB 0.5-7.4 : Providing white cement mortar with marble dust of mix 1:5 (1 white
cement : 5 marble dust) including cost of all materials, labour charges, HOM of machinery Cum 8238.00
complete as per specifications. Specification No. KBS

1.30 KSRB 0.5-8.1 : Providing fly ash sand mortar of mix 1:1.5:3 (1 cement : 1.5 fly ash : 3
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 4789.00
specifications. Specification No. KBS 0.5-2.4

1.31 KSRB 0.5-8.2 : Providing fly ash sand mortar of mix 1:2:4 (1 cement : 2 fly ash : 4 sand)
including cost of all materials, labour charges, HOM of machinery complete as per Cum 4004.00
specifications. Specification No. KBS 0.5-2.4

1.32 KSRB 0.5-8.3 : Providing fly ash sand mortar of mix 1:2.5:5 (1 cement : 2.5 fly ash : 5
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 3568.00
specifications. Specification No. KBS 0.5-2.4

1.33 KSRB 0.5-8.4 : Providing fly ash sand mortar of mix 1:3:6.5 (1 cement : 3 fly ash : 6.5
sand) including cost of all materials, labour charges, HOM of machinery complete as per Cum 3219.00
specifications. Specification No. KBS 0.5-2.4

1.34 Mud Mortar Cum 230.00

Page No. 3

Page 2 of 350
2.0 2.EARTHWORK FOR BUILDINGS

2.1 KSRB 2-1.1 : Earthwork in surface excavation in ordinary soil for levelling and lowering
the ground manually ( other than foundation of buildings, culverts, road drains and trenches
of pipe lines and cables ) and removing the excavated stuff to a distance not exceeding 50m
and lift upto 1.5m, excavated surface levelled and neatly dressed, disposed earth to be Cum 157.00
levelled after breaking of clods and neatly dressed as per specifications. specification. No.
KBS 2.1(a) / 2.3.1

2.2 KSRB 2-1.2 : Earthwork in surface excavation in Hard soil for levelling and lowering the
ground manually ( other than foundation of buildings, culverts, road drains and trenches of
pipe lines and cables ) and removing the excavated stuff to a distance not exceeding 50m and
lift upto 1.5m, excavated surface levelled and neatly dressed, disposed earth to be levelled Cum 220.00
after breaking of clods and neatly dressed as per specifications. specification. No. KBS
2.1(a) / 2.3.1. (P.No. 5/I.No. 2.2 of CSR 2015-16)

2.3 KSRB 2-2.1 : Earthwork excavation for foundation of buildings, water supply, sanitary lines
and electrical conduits either in pits or in trenches 1.5m and above in width, in ordinary
soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and
trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. Cum 189.00
after breaking of clods complete as per specifications. specification. No. KBS 2.1(a) / 2.3.5

2.4 KSRB 2-2.2 : Earthwork excavation for foundation of buildings, water supply, sanitary lines
and electrical conduits either in pits or in trenches 1.5m and above in width, in hard soil not
exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches,
stacking the excavated soil clear from edges of excavation with lead upto 50 m. after Cum 283.00
breaking of clods complete as per specifications. specification. No. KBS 2.1(b) / 2.3.5.
(P.No. 5/I.No. 2.4 of CSR 2015-16)

2.5 KSRB 2-2.3 : Excavation 1.5m and above in width in soft rock by blasting for foundation
of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches
not exceeding 1.5 m. in depth, stacking the excavated stuff from edges of excavation with
lead upto 50m including cost of explosives, labour and HOM of equipment complete as per Cum 506.00
specifications. specification. No. KBS 2.1.C / 2.9.4 / 2.18 / 2.19

2.6 KSRB 2-2.4 : Excavation 1.5m and above in width in soft rock without blasting for
foundation of buildings, water supply, sanitary lines and electrical conduits either in pits or
in trenches not exceeding 1.5 m. in depth, stacking the excavated stuff from edges of
excavation with lead upto 50m including cost of explosives, labour and HOM of equipment Cum 883.00
complete as per specifications. specification. No. KBS 2.1.C / 2.9.4 / 2.18 / 2.19

2.7 KSRB 2-2.5 : Excavation 1.5m and above in width in hard rock by blasting for foundation
of buildings, water supply, sanitary lines and electrical conduits either in pits or in trenches
not exceeding 1.5 m. in depth, stacking the excavated stuff from edges of excavation with
lead upto 50m including cost of explosives, labour and HOM of equipment complete as per Cum 513.00
specifications. specification. No. KBS 2.1.d / 2.3.4 / 2.18 / 2.19

2.8 KSRB 2.2.6 : Excavation 1.5m and above in width in hard rock by chiselling and / or
wedging, where blasting is prohibited for foundation of buildings, water supply, sanitary
lines and electrical conduits either in pits or in trenches 1.5 m. in depth stacking the Cum 1266.00
excavated stuff clear from the edge of excavation with lead upto 50m including cost of
labour complete as per specifications. Specification. No. KBS

2.9 KSRB 2.2.7: Benching hard rock 5 to 7.5 cm depth. for seating of foundation, including
cost of all labour complete as per specifications. specification. No. KBS 2.1(a) / 2.3.1 Sqm 1352.00

Page No. 5
2.11 KSRB 2-4 : Refilling available earth around pipe lines, cables in layers not exceeding
20cms in depth, compacting each deposited layer by ramming after watering with lead upto
50m. and lift upto 1.5 m. including cost of all labour complete as per specifications. Cum 76.00

Page 3 of 350
2.12 KSRB 2.5 : Earthwork excavation in soil deposits and filling sides of foundation upto
plinth in layers not exceeding 20cms. in depth, compacting each deposited layer by
ramming after watering with all lead and lift including cost of all labour complete as per Cum 254.00
specifications. specification. No. KBS 2.9.9 / 2.9.10.1 / 2.1.1
2.13 KSRB 2.6 : Providing and filling sand in foundation upto plinth to required depth for sub
soil treatment including watering ramming with all lead and lift complete as per Cum 2135.00
specifications.specification. No. KBS 2.10.2
2.14 KSRB 2.7 : Providing and removing shoring and strutting for protecting the sides of
foundation trenches, wherever required, including cost of all materials and labour complete Sqm 523.00
as per specifications. specification. No. KBS 2.5 / 2.13
2.15 KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm.
and down size, with approved sand including hand packing, ramming, watering, including
cost of all materials and labour with all lead and lift. complete as per specifications. Cum 2114.00
specification. No. KBS
2.16 KSRB 2.9 : Spreading and forming the excavated earth to required level, slope for an
average thickness of 75mm. in all classes of soils including breaking clods and tamping
manually alround the building and low laying areas complete as per Sqm 6.00
specifications.specification. No. KBS :
2.17 KSRB 2.10 : Providing sand cement bed with 5% cement with all leads for all materials
and lift of 1.5 m. machine mixed, laid in layers of 15cms. thick and well compacted for
foundation, including curing cost of materials labour and HOM complete as per Cum 3101.00
specifications. specification. No. KBS
2.18 KSRB 2.11 : Providing sand cement bed with 10% cement with all leads for all materials
and lift of 1.5 m. machine mixed, laid in layers of 15cms. thick and well compacted for
foundation, including curing cost of materials labour and HOM complete as per Cum 3732.00
specifications. specification. No. KBS

2.19 KSRB 2.12 : Providing sand piles with all leads and lift of 1.5 m. for stabilising foundation
after duly making 5 cms. dia holes to a depth of 1.2 to 1.5 m. at 0.5 m c to c and filling with
sand and tamping wherever required including cost of materials, labour complete as per Sqm 216.00
specifications.
Page No. 6
2.21 KSRB 2.14-1: Extra for additional lift of 1.5m. or part thereof for excavation In loose /
Cum 13.00
soft or hard soil including cost of materials, labour complete as per specifications.
2.22 KSRB 2.14-2: Extra for additional lift of 1.5m. or part thereof for excavation In loose /
soft or hard soil including cost of materials, labour complete as per specifications. in soft or Cum 22.00
hard rock
2.23.1 Earth work excavation for foundation of structures by mechanical means as per
drawing and technical specification, including setting out, construction of shoring and
bracing, removal of stumps and other deleterious matter, dressing of sides and bottom,
backfilling the excavation earth to the extent required and utilising / transporting the Cum 53.00
remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - in Ordinary/Hard soil.

2.23.2 Earth work excavation for foundation of structures by mechanical means as per
drawing and technical specification, including setting out, construction of shoring and
bracing, removal of stumps and other deleterious matter, dressing of sides and bottom,
backfilling the excavation earth to the extent required and utilising / transporting the Cum 71.00
remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - in Ordinary Rock (not
requiring blasting)

2.23.3 Earth work excavation for foundation of structures by mechanical means as per
drawing and technical specification, including setting out, construction of shoring and
bracing, removal of stumps and other deleterious matter, dressing of sides and bottom,
backfilling the excavation earth to the extent required and utilising / transporting the Cum 737.00
remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - Hard Rock ( requiring
blasting )

Page 4 of 350
2.23.4 Earth work excavation for foundation of structures by mechanical means as per
drawing and technical specification, including setting out, construction of shoring and
bracing, removal of stumps and other deleterious matter, dressing of sides and bottom,
backfilling the excavation earth to the extent required and utilising / transporting the Cum 253.00
remaining earth locally upto 1.00km lead. (Depth upto 3.00 Mts) - Marshy soil-

2.24 Earth work for lowering and levelling the ground other than foundation works by
mechanical means upto 3.00 depth, including providing shoring and strutting, removal of
stumps and other deleterious matter, dressing of sides and bottom, filling back the Cum 68.00
excavation earth to the extent required including the cost of labour & HOM of machineries,
as per drawing and technical specification.
Page No. 7

3.0 3.ANTI TERMITE TREATMENT

3.1 KSRB-3.1 Supplying chloropyriphos emulisifiable concentrate of 20%, in sealed


containers including delivery as specified sales tax, transport, Insurance and other levies L 242.00
complete as per specifications. Specification No. KBS
3.2 KSRB-3.2: Providing and injecting chemical emulsion for Pre- constructional Anti-
Termite Treatment, creating continuous chemical barrier under and around the column
pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of
wall and floor, along the external perimeter of building, expansion joints, over the top
surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits,
with chloropyriphos emulsifiable concentrates of 20% concentration, including cost of Sqm 103.00
chemical, diluting in water to one percent concentration, labour, HOM of equipments,
complete as per specifications. (Plinth area of the building at ground floor only shall be
measured ) Specification No. KBS : 3.2.6 / 3.2.7

3.3 KSRB-3.3 : Providing, injecting chemical emulsion for Pre-constructional Anti-Termite


Treatment along external walls where the apron is not provided using chemical emulsion
at 7.5 Litre/sqm of the vertical surface of the substructure to a depth of 300mm. Including
excavation of channel along the wall and redoing with chlorophyriphos emulsion concentrate m 67.00
20% diluting in water to 1% concentration, including cost of chemicals, diluting in water to
one percent concentration, labour, HOM of equipments, complete as per specifications.
Specification No. KBS : 3.3.3

3.4 KSRB-3.4: Providing, injecting chemical emulsion for Pre-constructional Anti-Termite


Treatment along external walls below concrete or masonry apron using chemical
emulsion at 2.25 litre/m. including drilling and plugging of holes, with chlorophyriphos
emulsion concentrate 20% diluting in water to 1% concentration, including cost of m 43.00
chemicals, diluting in water to one percent concentration, labour, HOM of equipments,
complete as per specifications. Specification No. KBS : 3.3.4

3.5 KSRB 3.5: Providing, injecting chemical emulsion for Pre-constructional Anti-Termite
Treatment of soil under existing floors using chemical emulsion at one litre / hole 30mm
apart including drilling 12mm. dia holes and plugging with cement mortar 1:2 proportion to
match with the existing floors with chlorophyriphos emulsion concentrate 20%, including Sqm 226.00
cost of chemical diluting in water to one percent concentration, labour, HOM of
equipments, complete as per specifications. (P. No. 9/ I. No. 3.5 of CSR 2015-16)

3.6 KSRB.3-6: Providing, Injecting chemical emulsion for Pre-constructional Anti-Termite


Treatment of existing masonry using chemical emulsion at one liter / hole at 300mm
intervals including drilling of holes at 45 degree and plugging them with cement mortar 1:2
to the full depth of the hole with Chloropyriphos emulsifiable concentration 20% including m 71.00
cost of chemical diluting in water to one percent concentration, labour, HOM of
equipments, complete as per specifications. Specification No. KBS : 3.3.5

Page No. 9

Page 5 of 350
3.7 KSRB 3.7: Providing, injecting chemical emulsion for Pre-constructional Anti-Termite
Treatment at points of contacts of wood work by chemical emulsion Chloropyriphos ( in
oil or kerosene based solution ) at 0.5 liters per hole by drilling 6mm. dia holes at downword
angle of 45 degree at 150mm. c to c and sealing the same including cost of chemicals, m 236.00
diluting in water to one percent concentration, labour, HOM of equipments, complete as per
specifications. Specification No. KBS : 3.3.7

3.8 Providing general disinfection services, spraying of insecticide and pesticide inside and
outside the building ( flies, bedbugs,lizards, cockroaches, spiders caterpillars etc., including
cost of materials labour lead lift, hire charges of equipments etc., complete. Sqm 27.00

Page No. 10
4.0 4.CEMENT CONCRETE

4.1 KSRB 4-1.1: Providing and laying in position plain cement concrete of mix 1:2:4 with
OPC cement @ 240kgs, with 40mm and down size graded granite metal coarse aggregates
@0.878cum and fine aggregates @ 0.459cum machine mixed, concrete laid in layers not
exceeding 15 cms. thick, well compacted, in foundation, including cost of all materials, Cum 5213.00
labour, HOM of machinery, curing complete as per specifications. Specification No. KBS
4.1, 4.2

4.2 KSRB 4-1.2 : Providing and laying in position plain cement concrete of mix 1:3:6 with
OPC cement @ 220kgs, with 40mm and down size graded granite metal coarse aggregates
@0.892cum and fine aggregates @ 0.465cum machine mixed, machine mixed, concrete laid
in layers not exceeding 15 cms. thick, well compacted, in foundation including cost of all Cum 5046.00
materials, labour, HOM of machinery, curing complete as per specifications. Specification
No. KBS 4.1, 4.2. (P.No. 12/I.No. 4.2 of CSR 2015-16)

4.3 KSRB 4-1.3 : Providing and laying in position plain cement concrete of mix 1:4:8 with
OPC cement @ 180kgs, with 40mm and down size graded granite metal coarse aggregates
@0.85cum and fine aggregates @ 0.57cum machine mixed, machine mixed, concrete laid in
layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all Cum 4867.00
materials, labour, HOM of machinery, curing complete as per specifications. Specification
No. KBS 4.1, 4.2. (P.No.12, I.No. 4.3 of PWD SR 2015-16)

4.4 KSRB 4-1.4 : Providing and laying in position plain cement concrete of mix 1:5:10 with
OPC cement @ 160kgs, with 40mm and down size graded granite metal coarse aggregates
@0.86cum and fine aggregtes @ 0.58cum machine mixed, machine mixed, concrete laid in
layers not exceeding 15 cms. thick, well compacted, in foundation, including cost of all Cum 4722.00
materials, labour, HOM of machinery, curing complete as per specifications. Specification
No. KBS 4.1, 4.2. (P.No.12, I.No. 4.4 of PWD SR 2015-16)

4.5 KSRB 4-1.5 : Providing and laying in position plain cement concrete of mix M20 with
OPC cement @ 300kgs, with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregtes @ 0.43cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not exceeding 15 Cum 5542.00
cms. thick, well compacted, in foundation, plinth and cills, including cost of all materials,
labour, HOM of machinery, curing complete as per specifications. Specification No. KBS
4.1, 4.2. (P.No.12, I.No. 4.5 of PWD SR 2015-16)

4.6 KSRB 4-1.6 ; Providing and laying in position plain cement concrete of mix 1:2:4 with
cement @ 240kgs, with 20mm and down size graded granite metal coarse aggregates @ 0.69
cum and fine aggregtes @ 0.459cum, machine mixed, concrete laid in layers not exceeding
15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of all
materials, labour, HOM of machinery, curing complete as per specifications. Specification Cum 5441.00
No. KBS 4.1, 4.2. (P.No.12, I.No. 4.6 of PWD SR 2015-16)

Page No. 12

Page 6 of 350
4.7 KSRB 4-1.7 : Providing and laying in position plain cement concrete of mix 1:3:6 with
OPC cement @ 220kgs, with 20mm and down size graded granite metal coarse aggregates
@0.84cum and fine aggregtes @ 0.56cum, machine mixed, concrete laid in layers not
exceeding 15 cms. thick, well compacted, in foundation, plinth and cills, ncluding cost of Cum 5282.00
all materials, labour, HOM of machinery, curing complete as per specifications.
Specification No. KBS 4.1, 4.2

4.8 KSRB 4-1.8 : Extra for laying cement concrete under water including cost of pumping or
Cum 103.00
dewatering and clearing slush as per specifications. Specification No. KBS 4.2, 4.8
4.9 KSRB 4-1.9 : Extra for laying cement concrete under foul conditions. Specification No.
Cum 139.00
KBS
4.10 KSRB 4.2.1 : Providing and laying in position reinforced cement concrete of Design mix
M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse
aggregates @0.70 cum and fine aggregtes @ 0.47cum, with super plasticisers @ 3 liters
confirming to is 9103-1999 reafirmed-2008 at machine mixed, concrete laid in layers not
exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals,
retaining walls, return walls, walls (any thickness) including attached pilasters, Cum 6221.00
columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc.,
including cost of all materials, labour, HOM of machinery, curing, complete but excluding
cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6

4.11 KSRB 4.2.2 : Providing and laying in position reinforced cement concrete of Design mix
M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.460 cum, with super plasticisers @ 3 liters
confirming to is 9103-1999 reafirmed-2008, machine mixed, concrete laid in layers not
exceeding 15 cms thick, vibrated for all works in foundation for footings, pedastals,
retaining walls, return walls, walls (any thickness) including attached pilasters, Cum 6011.00
columnspillars, posts, struts, buttresses, bed blocks, anchor blocks & plinths etc.,
including cost of all materials, labour, HOM of machinery, curing, complete but excluding
cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6

4.12 KSRB 4.2.7 : Providing and laying in position reinforced cement concrete of design mix
M25 with OPC cement @ 340kgs, with 20mm and down size graded granite metal coarse
aggregates @0.70cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not
exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs,
staircase, lintles and beams retaining walls, return walls, walls (any thickness)
including attached pilasters, columns, ,pillars, posts, struts, buttresses, string or lacing Cum 6367.00
courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc.,
including cost of all materials, labour, HOM of machinery, curing, complete but excluding
cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6

Page No. 13
4.13 KSRB 4.2.8: Providing and laying in position reinforced cement concrete of design mix
M20 with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008, machine mixed, concrete laid in layers not
exceeding 15 cms thick, vibrated for all works in ground floor level for roof slabs,
staircase, lintles, and beams retaining walls, return walls, walls (any thickness)
including attached plasters, columns, pillars, posts, struts, buttresses, string or lacing Cum 6158.00
courses, parapets, coping, bed blocks, anchor blocks, plain window cills, fillets etc.,
including cost of all materials, labour, HOM of machinery, curing, complete but excluding
cost of reinforcement as per specifications. Specification No. KBS 4.1, 4.6. (P. No. 14/ I.No.
4.13 of CSR 2015-16)

4.18 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for flat surface such as roofs, landings, balconies and likes, thickness
upto 200 mm including cost of all materials, labour complete as per specificaitons.up to Sqm 313.00
3.50m from Ground level. Specification No. KBS 4.6.2

Page 7 of 350
4.19 KSRB 4.2.10 : Providing and laying in position reinforced cement concrete of design mix
M20 with OPC cement @ 24kgs, with 12mm and down size graded granite metal coarse
aggregates @0.05175cum and fine aggregtes @ 0.0345cum, with superplastisiser @0.225lts,
machine mixed, well compacted for plain chajja of 7.5 cms. average thickness, upto ground Sqm 456.00
floor level, including cost of all materials, labour, HOM of machinery, finishing, curing,
complete but excluding cost of reinforcement as per specifications. Specification No. KBS
4.1, 4.6

4.20 KSRB 4.2.11 : Providing and laying in position reinforced cement concrete of design mix
M20 with OPC cement @ 27.20kgs, with 12mm and down size graded granite metal coarse
aggregates @0.05865cum and fine aggregtes @ 0.0391cum, with superplastisiser @0.225lts,
machine mixed, well compacted for plain chajja of 8.5 cms. average thickness, upto ground Sqm 514.00
floor level, including cost of all materials, labour, HOM of machinery, finishing, curing,
complete but excluding cost of reinforcement as per specifications. Specification No. KBS
4.1, 4.6

4.21 KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with
plastering ( labour charges only ) as per specifications. Specification No. KBS. (P. No. 14/ m 20.00
I.No. 4.21 of CSR 2015-16)
4.22 KSRB 4-3.1 : Extra if vibrator is used for Item No.4-1 to 4-8 as per specifications.
Cum 17.00
Specification No. KBS 4.2.6
4.23 KSRB 4-3.2 : Deduct where machine mixing is not done Specification No. KBS 4.2.2.5 /
Cum 17.00
4.3.2.2
4.24 KSRB 4-4.1 : Extra for use of water proofing compound in Cement concrete of mix
Cum 255.00
1:1:2,at one kg of compound per bag of cement. Specification No. KBS
4.25 KSRB 4-4.2 : Extra for use of water proofing compound in Cement concrete of mix
Cum 189.00
1:1.5:3,at one kg of compound per bag of cement. Specification No. KBS
4.26 KSRB 4-4.3 : Extra for use of water proofing compound in Cement concrete of mix
Cum 151.00
1:2:4,at one kg of compound per bag of cement. Specification No. KBS
Page No. 14
4.27 KSRB 4-5 : Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild
steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop
chajja, facia, backing to cup boards including cost of all materials, labour, providing and Sqm 967.00
removing form work HOM of machineries, curing, complete as per specifications.
Specification No. KBS
4.28 KSRB 4-6.1 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for foundations, footings, bases of columns for mass concrete
including cost of all materials, labour complete as per specificaitons. Specification No. KBS Sqm 231.00
4.6.2
4.29.2 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 550.00
than 3.50m from ground level. - 0 to 5 mtrs. Specification No. KBS 4.6.2

4.29.3 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 730.00
than 3.50m from ground level. - 0 to 6 mtrs. Specification No. KBS 4.6.2

4.29.4 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 890.00
than 3.50m from ground level. - 0 to 7 mtrs. Specification No. KBS 4.6.2

4.29.5 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 1050.00
than 3.50m from ground level. - 0 to 8 mtrs. Specification No. KBS 4.6.2

Page 8 of 350
4.29.6 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 1300.00
than 3.50m from ground level. - 0 to 9 mtrs. Specification No. KBS 4.6.2

4.29.7 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 1550.00
than 3.50m from ground level. - 0 to 10 mtrs. Specification No. KBS 4.6.2

4.29.8 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 1800.00
than 3.50m from ground level. - 0 to 11 mtrs. Specification No. KBS 4.6.2

4.29.9 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 2060.00
than 3.50m from ground level. - 0 to 12 mtrs. Specification No. KBS 4.6.2

4.29.10 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 2310.00
than 3.50m from ground level. - 0 to 13 mtrs. Specification No. KBS 4.6.2

4.29.11 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 2580.00
than 3.50m from ground level. - 0 to 14 mtrs. Specification No. KBS 4.6.2

4.29.12 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 2900.00
than 3.50m from ground level. - 0 to 15 mtrs. Specification No. KBS 4.6.2

4.29.13 KSRB 4-6.2 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for suspended floors, landings, balconies and likes, thickness upto 200
mm including cost of all materials, labour complete as per specificaitons for heights more Sqm 3200.00
than 3.50m from ground level. - 0 to 16 mtrs. Specification No. KBS 4.6.2

4.30 KSRB 4-6.3 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for flat surface such as suspended floors, roofs, landings, balconies
and likes, thickness above 200 mm including cost of all materials, labour complete as per Sqm 384.00
Specification. Specification No. KBS 4.6.2
4.31 KSRB 4-6.4 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for vertical surface such as walls at any thickness, including attached
pilasters, buttresses, plinth cills and string courses cost of all materials, labour complete as Sqm 293.00
per specifications. Specification No. KBS 4.6.2
Page No. 15
4.32 KSRB 4-6.5 : Providing and removing centering, shuttering, strutting, propping etc., for
columns, pillars, post and struts, square / rectangular/ polygon in plan including cost of all
materials, labour complete as per specifications. Specification No. KBS 4.6.2 Sqm 366.00

4.33 KSRB 4-6.6 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for columns, pillars,post and struts, circular or curved in plan
including cost of all materials, labour complete as per specifications. Specification No. KBS Sqm 859.00
4.6.2

Page 9 of 350
4.34 KSRB 4-6.7 :Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for sides and soffits of beams, beam haunchings, cantilever girders,
bressumers and lintels not exceeding 1m in depth including cost of all materials, labour Sqm 256.00
complete as per specifications. Specification No. KBS 4.6.2
4.35 KSRB 4-6.8 : Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for sides and soffits of beams, beams haunchings, cantilelver,
girders, bressumers and lintels exceeding 1m in depth including cost of all materials, Sqm 338.00
labour complete as per specifications. Specification No. KBS 4.6.2
4.36 KSRB 4-6.9 :Providing and removing centering, shuttering, strutting, propping etc., for
edges of slabs and breaks in floor including cost of all materials, labour complete as per Sqm 678.00
specifications. Specification No. KBS 4.6.2
4.37 KSRB 4-6.10 :Providing and removing centering, shuttering, strutting, propping etc., for
chajjas, corbels etc., including edges including cost of all materials, labour complete as per Sqm 270.00
specifications. Specification No. KBS 4.6.2
4.38 KSRB 4-6.11 :Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for Stairs (excluding landing) except spiral staircase including cost of
all materials, labour complete as per specificaiton. Specification No. KBS 4.6.2 Sqm 475.00

4.39 KSRB 4-6.12 :Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for cornices and mouldings including cost of all materials, labour Sqm 510.00
complete as per specifications. Specification No. KBS 4.6.2
4.40 KSRB 4-6.13 :Providing and removing, centering, shuttering, strutting, propping etc.,
and removal of form work for vertical fins and vertical sun breakers including cost of all
materials, labour complete as per specifications. Specification No. KBS 4.6.2 Sqm 451.00

4.41 KSRB 4-6.14 :Providing and removing centering, shuttering, strutting, propping etc., and
removal of form work for sloping or battering surface including folded plates where
inclination to horizontal plane does not exceed 30 degree requiring shuttering only on the Sqm 422.00
under side including cost of all materials, labour complete as per specifications.
Specification No. KBS 4.6.2
Page No. 16
4.42 KSRB 4-6.15 : Providing and removing centering, shuttering, strutting, propping etc.,
and removal of form work for where inclination to horizontal plane exceeds 30 degree
(where shuttering may be provided both on under side and upper side if required) including Sqm 653.00
cost of all materials, labour complete as per specifications. Specification No. KBS 4.6.2

4.43.1 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using 10-15 cms. dia
best quality casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the
ground), the distance between two rows being 1.25m and spacing of posts being 2m in both
rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c m 303.00
including longitudinal and transveres middle braces to step up and providing platform with
casurina poles, forms tied up using coir rope complete as per specifications.

4.43.2 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using 10-15 cms. dia
best quality casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the
ground), the distance between two rows being 1.25m and spacing of posts being 2m in both
rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c Cum 227.00
including longitudinal and transveres middle braces to step up and providing platform with
casurina poles, forms tied up using coir rope complete as per specifications. - Scaffolding
for stone masonry work converted to cum.

4.43.3 KSRB 4-7 : Providing 2 legged scaffolding for stone masonry work using 10-15 cms. dia
best quality casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the
ground), the distance between two rows being 1.25m and spacing of posts being 2m in both
rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c Sqm 108.00
including longitudinal and transveres middle braces to step up and providing platform with
casurina poles, forms tied up using coir rope complete as per specifications. - Scaffolding
for stone masonry work converted to sqm.

Page 10 of 350
4.44.1 KSRB 4-8 : Providing two legged scaffolding for brick masonry work using 10-15 cms.
dia best quality Casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the
ground) the distance between two rows being 1.25m and spacing of post being 2m in both
rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c
including longitudinal and transveres middle braces to step up and providing platform with Cum 256.00
casurina poles, forms tied up using coir rope complete as per specifications - for non
modular brick work (Non modular standard bricks : 4x0.23x3=2.76 cum)

4.44.2 KSRB 4-8 : Providing two legged scaffolding for brick masonry work using 10-15 cms.
dia best quality Casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the
ground) the distance between two rows being 1.25m and spacing of post being 2m in both
rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c
including longitudinal and transveres middle braces to step up and providing platform with Cum 297.00
casurina poles, forms tied up using coir rope complete as per specifications - for modular
brick work (modular standard bricks : 4x0.20x3=2.40 cum)

4.44.3 KSRB 4-8 : Providing two legged scaffolding for brick masonry work using 10-15 cms.
dia best quality Casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the
ground) the distance between two rows being 1.25m and spacing of post being 2m in both
rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c Sqm 59.00
including longitudinal and transveres middle braces to step up and providing platform with
casurina poles, forms tied up using coir rope complete as per specifications - for non
modular brick work

4.44.4 KSRB 4-8 : Providing two legged scaffolding for brick masonry work using 10-15 cms.
dia best quality Casurina poles of 4m over all length (3m +0.5m projection + 0.5m In to the
ground) the distance between two rows being 1.25m and spacing of post being 2m in both
rows with 2 horizontal posts with 0.5 mm overlap on either side and braces at 2 m c to c Sqm 59.00
including longitudinal and transveres middle braces to step up and providing platform with
casurina poles, forms tied up using coir rope complete as per specifications - for modular
brick work

4.45 KSRB 4.9.1 : Providing mild steel reinforcement for R.C.C work including straightening,
cutting, bending, hooking, placing in position, lapping and / or welding wherever required,
tying with binding wire and anchoring to the adjoining members wherever necessary
complete as per design (laps, hooks and wastage shall not be measured and paid) cost of q 6048.00
materials, labour, HOM of machinery complete as per specifications. Specification No. KBS
4.6.3

4.46.2 KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including
straightening, cutting, bending, hooking, placing in position, lapping and / or welding
wherever required, tying with binding wire and anchoring to the adjoining members
wherever necessary complete as per design (laps, hooks and wastage shall not be measured Tonne 56050.00
and paid) cost of materials, labour, HOM of machinery complete as per specifications.
Specification No. KBS 4.6.3 - TMT bars Fe 500

4.46.3 KSRB 4.9.2 : Providing T.M.T steel reinforcement for R.C.C work including
straightening, cutting, bending, hooking, placing in position, lapping and / or welding
wherever required, tying with binding wire and anchoring to the adjoining members
wherever necessary complete as per design (laps, hooks and wastage shall not be measured Tonne 56701.00
and paid) cost of materials, labour, HOM of machinery complete as per specifications.
Specification No. KBS 4.6.3 - TMT bars Fe 550

Page No. 17
4.47 Lift charges for steel of all diameters for additional floors over ground floor per floor
height of 3.5 m. or part thereof cost of labour, complete as per specifications. (P.No. 18, Tonne 472.00
I.No. 4.47 of PWD SR 2015-16)
4.48 Providing and laying cement concrete using 20 mm and down size granite coarse
aggregates and fine aggregates of ready mixed concrete (RMC) M 20 for R.C.C works laid
in 15 cms thick layers and well compacted vibrating, curing, for raft foundation column Cum 5879.00
footing , main and secondary beams with all lead and lifts etc., complete (exclusive of cost
of steel and fabrication charges.)

Page 11 of 350
4.49.1 Providing and laying cement concrete using 20mm and down size granite coarse aggregates
and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and
well compacted including vibrating curing etc., with all lead and lift etc., complete. Cum 5879.00
(exculsive of cost of steel and fabrication charges) - Ready mixed Cement concrete for
Beams, Staircase and Roof with M-20
4.49.2 Providing and laying cement concrete using 20mm and down size granite coarse aggregates
and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and
well compacted including vibrating curing etc., with all lead and lift etc., complete. Cum 6065.00
(exculsive of cost of steel and fabrication charges) - Ready mixed Cement concrete for
Beams, Staircase and Roof with M-25
4.49.3 Providing and laying cement concrete using 20mm and down size granite coarse aggregates
and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and
well compacted including vibrating curing etc., with all lead and lift etc., complete. Cum 6243.00
(exculsive of cost of steel and fabrication charges) - Ready mixed Cement concrete for
Beams, Staircase and Roof with M-30
4.49.4 Providing and laying cement concrete using 20mm and down size granite coarse aggregates
and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and
well compacted including vibrating curing etc., with all lead and lift etc., complete. Cum 6485.00
(exculsive of cost of steel and fabrication charges) - Ready mixed Cement concrete for
Beams, Staircase and Roof with M-35
4.49.5 Providing and laying cement concrete using 20mm and down size granite coarse aggregates
and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and
well compacted including vibrating curing etc., with all lead and lift etc., complete. Cum 6728.00
(exculsive of cost of steel and fabrication charges) - Ready mixed Cement concrete for
Beams, Staircase and Roof with M-40
Note Note: The RMC should be obtained only from the plants certified by the quality
council of India as per letter No, CE, C&B, AE-2, 2015-16 Dt.02.09.2015.
4.50 Providing and mixing synthetic fibers 100% virgin triangular monofilament
polyester/ploypropylene fibers, 12mm in cut length for use as secondary fiber reinforcement
in RMC/ in-situ concrete at 900 grams per cubic meter of concrete. (grade of concrete - M15 Cum 338.00
to M60)
4.51 Providing and mixing fibermesh MD(Multi Dimensional) Graded (fibermesh inforce e3)
fibrilated (interconnected bundles of fibers that open up during the mix process) 100% virgin
Polypropylene fibers contains no reprocessed olefin materials and are specially
manufactured with 25 individual unique fiber design to an optimum gradation for use as
complete secondary reinforcement. Application per cubic meter shall equal a minimum of
0.1% by volume (0.9kg per cubic meter) in the concrete. Fibermesh MD Graded Cum 710.00
Polypropylene fibrilated fiber should confirm to ASTM C 1116 type III 4.1.3 ASTM C 1116
performance level 1% ASTM C 1339 (Minimum average residual strength of 0.35 Mpa).

4.52 Providing and mixing fibermesh stealth e3 Fibermesh150multi dimensional graded


multifilamenrt 100%virgin polypropylene fibres contains no reprocesserd olfrin materials
and are specifically manufactured for use as concrete secondary reinforcement. Application Cum 410.00
per cubic meter shall be @ 0.9kg to 1.8kg per cum of concrete. Fibermesh stealth e3 shall
confirm to ASTM C 1116 type 111.4.106.
4.53 Providing and casting reinforced cement concrete racks with design mix M20, granite or
trap jelly 12mm and down size 5 cms thick and below with reinforcements of 6mm dia MS
bars at 15 cms. Centre to centre for main reinforcement and at 30cms centre to centre for
distribution including supports wherever necessary with burnt brick in CM 1:4 including Cum 887.00
centring, form work, curing etc., complete (inclusive of cost of steel and fabrication
charges).

Page No. 18
4.54 Providing RCC loft (atta) 7.5cms thick with cement concrete design mix M20 using clean
granite or trap jelly of 20mm and down size with necessary reinforcements at 20cms centre
to centre as per design including form work, centring, curing, etc., complete (exclusive of Sqm 450.00
cost of steel and fabrication charges).
4.55 Providing and fixing RCC slabs 5 cms thick for wall shelves with 12mm and down size jelly
cement concrete design mix M20 including CM 1:3 plaster finishing, curing etc., complete Sqm 564.00
(excluding the cost of steel and fabrication charges

Page 12 of 350
4.56.1 Providing RCC design mix M20 using granite metal 20mm and down size for 7.5 cms thick
solid parapet or perforated as per design, specification and directions.(exclusive of cost of
steel and fabrication charges) including necessary centring, form work and finishing smooth Sqm 443.00
with CM (1:3) etc., complete. - 7.5 cms thick
4.56.2 Providing RCC design mix M20 using granite metal 20mm and down size for 7.5 cms thick
solid parapet or perforated as per design, specification and directions.(exclusive of cost of
steel and fabrication charges) including necessary centring, form work and finishing smooth Sqm 636.00
with CM (1:3) etc., complete. - 10cms thick
4.57 Providing and mixing Alkali resistant glass fibres HD12 to arrest plastic shrinkage cracks
and to provide as a secondary reinforcement in concrete at 600 gms/cum of concrete and
containing minimum 127 millions of fibres of length 12 mm , diameter 14 microns specific
gravity 2.68, modulus of elasticity 72 Gpa and having the aspect ratio (length / dia) of 857, Cum 330.00
including cost of labour, materials and HOM of machineries etc complete (Note: Rate of
cum of concrete)

Page No. 19
7 Lift Charges : An additional rate of Rs. 50.00 cum per floor may be added for every
additonal floo for items under Sl.No. 4.1, to 4.18, 4,19, 4,20, 4,27 4,28, 4,55, 4,57, 4,58,
4,58.2, 4.30 to 4.42, for 4.43 for 4.43 1 to 4.44.4 an additional rate of Rs. 5/floor may be
added.
8 Centering height of 3.5 meters is considered for item No. 4.28, 4,30, to 4,44.4 An additional
rates Rs. 20 shall be added for every additional meter or part there of for the above limits.

9 usage of ground Granulated Blast Furance Slag


Use of 25% of Ground Granulated Blast Furance Slag of minimum 380 mtsq. Per kg
fineness to replace cement in the cement concrete nominal mix as given below to economize
and to reduce the concrete cost proportionately.
10 The Different in cost of cement for RMC items shall be effected for every price revision of
cement
11 RMC : While using RMC, taking out the samples at works site is mandotory for conducting
necessary tests. It is the responsibility of the contractor to assure and ensure quality of RMC
at the work spots as per design mix for which executive engineer shall obtain necessary test
certifiicates as per IS Standards.

12 TMT Steel : For all RCC works the Contractor shall purchases the TMT Steel
manufactuered by the authorised dealers and necessary physical tests for the TMT Steel so
procured shall be conducted. As per IS 1786 if necessary chemical tests may also be insisted.

Un road works only Round TMT bars shall be used for dowel bars. Shall be used dowel
bars.
For lapping steel reinforcement, preferably 25mm and above, only welding spices shall be
done.
Page No. 21

5.0 5.STONE WORK

5.1 KSRB 5-1.1 : Providing and constructing granite / trap / basalt rubble stone masonry in
foundation with mud mortar (uncoursed), bond stones at two m. apart in each course
including cost of materials, labour, curing complete as per specifications. KBS 5.1.12 Cum 1744.00

5.2 KSRB 5.1-2 : Providing and constructing granite / trap / basalt rubble stone masonry in
foundation with cement mortar 1:8 (uncoursed), bond stones at two m. apart in each course
including cost of materials, labour, curing complete as per specifications.KBS 5.1.12 Cum 3072.00

5.3 KSRB 5.1-3 : Providing and constructing granite / trap / basalt rubble stone masonry in
foundation with cement mortar 1:6 (uncoursed), bond stones at two m. apart in each course
including cost of materials, labour, curing complete as per specifications.KBS 5.1.12 Cum 3249.00

Page 13 of 350
5.4 KSRB 5.2-1 : Providing and constructing granite / trap / basalt size stone masonry in
foundation with mud mortar, stone hammerd dressed in courses not less than 20 cms high,
bond stones at two m. apart in each course including cost of materials, labour, curing Cum 2911.00
complete as per specifications. KBS 5.1.12
5.5 KSRB 5.2-2 : Providing and constructing granite / trap / basalt size stone masonry in
foundation with cement mortar 1:8, stone hammerd dressed in courses not less than 20 cms
high, bond stones at two m. apart in each course including cost of materials, labour, curing Cum 4037.00
complete as per specifications. KBS 5.1.13
5.6 KSRB 5.2-3 : Providing and constructing granite / trap / basalt size stone masonry in
foundation with cement mortar 1:6, stone hammerd dressed in courses not less than 20 cms
high, bond stones at two m. apart in each course including cost of materials, labour, curing Cum 4187.00
complete as per specifications. KBS 5.1.13
5.9 KSRB 5.3-3 : Providing and constructing granite / trap / basalt size stone masonry in
basement with cement mortar 1:6, edges of stones chistle dressed in courses not less than 15
cms high, bond stones at two m. apart in each course including cost of materials, labour, Cum 5005.00
curing complete as per specifications. KBS 5.1.13
5.12 KSRB 5.4-3 : Providing and constructing granite / trap / basalt size stone masonry in
superstructure with cement mortar 1:6 , edges of stones chistle dressed in courses not less
than 15 cms high, bond stones at two m. apart in each course including cost of materials, Cum 5249.00
labour, scaffolding, curing complete as per specifications. KBS 5.1.13
5.13 KSRB 5.4-4 : Providing and constructing granite / trap / basalt size stone masonry in
superstructure with cement mortar 1:4 , edges of stones chistle dressed in courses not less
than 15 cms high, bond stones at two m. apart in each course including cost of materials, Cum 5574.00
labour, scaffolding, curing complete as per specifications. KBS 5.1.13
5.14 KSRB 5-5 : Extra lift charges for size stone masonry above ground floor for every additional
Cum 195.00
floor. KBS 5.1.13
5.15 KSRB 5-6 : Extra for constructing stone masonry in square or rectangular pillars complete as
Cum 300.00
per specifications. KBS 5.1.13
5.16 KSRB 5-7 : Extra for constructing masonry in circular pillars including cost of extra
Cum 696.00
materials and labour complete as per specifications. KBS 5.1.13
5.17 KSRB 5-8.1 : Providing one line dressing to granite stone slab / granite stone masonry as per
Sqm 545.00
specifications .KBS 5.1.13
Page No. 23
5.18 KSRB 5-8.2 : Providing two line dressing to granite stone slab / granite stone masonry as per
Sqm 909.00
specifications. KBS 5.1.13
5.19 KSRB 5-8.3 : Proiding three line dressing to granite stone slab / granite stone masonry as per
Sqm 1272.00
specifications. KBS 5.1.13
5.20 KSRB 5-8.4 : Providing pulmane finish only on three line dressed surface as per
Sqm 359.00
specifications. KBS 5.1.13
5.21 KSRB 5-8.5 : Providing quoin dressing to stone masonry and stone slabs, two line 5 cms
wide on each face as per specifications.(measurement including mortar joints). KBS 5.1.13 m 91.00

5.22 KSRB 5-9 : Providing chamfering edges to stone slab 2.5 cms. wide as per specifications.
m 35.00
(only chamfered length shall be recorded) KBS 5.1.13
5.23 KSRB 5-10 : Providing hammer dressing to size stones as per specifications. KBS 5.1.13.3
No 6.00

5.24.1 KSRB 5-11 : Providing and constructing load bearing wall with cement concrete cavities
blocks ( hollow blocks ) of size 400x200x200 mm Grade B having a minimum face shell
thickness of 30mm and web thickness of 25mm with block density between 1100 kg/m3 and
1500 kg/m3 having a minimum average compressive strength of 5.00 N/mm2 confirming to
IS 2185 (Part) : 2005 and constructed with CM 1:4 , as per IS 2572:2005 including cost of Sqm 948.00
all materials, labour charegs, scaffolding, curing complete as per specifications. KBS No.5.4

Page 14 of 350
5.24.2 KSRB 5-11 : Providing and constructing load bearing wall with cement concrete cavities
blocks ( hollow blocks ) of size 400x150x200 mm Grade B having a minimum face shell
thickness of 30mm and web thickness of 25mm with block density between 1100 kg/m3 and
1500 kg/m3 having a minimum average compressive strength of 5.00 N/mm2 confirming to Sqm 919.00
IS 2185 (Part) : 2005 and constructed with CM 1:4 , as per IS 2572:2005 including cost of
all materials, labour charegs, scaffolding, curing complete as per specifications. KBS No.5.4

5.25.1 KSRB 5-11 : Providing and constructing load bearing wall with cement concrete cavities
blocks ( hollow blocks ) of size 400x200x200 mm Grade B having a minimum face shell
thickness of 30mm and web thickness of 25mm with block density between 1100 kg/m3 and
1500 kg/m3 having a minimum average compressive strength not lessthan 3.5 N/mm2 Sqm 919.00
confirming to IS 2185 (Part) : 2005 and constructed with CM 1:4 , as per IS 2572:2005
including cost of all materials, labour charegs, scaffolding, curing complete as per
specifications. KBS No.5.4

5.25.2 KSRB 5-11 : Providing and constructing load bearing wall with cement concrete cavities
blocks ( hollow blocks ) of size 400x150x200 mm Grade B having a minimum face shell
thickness of 30mm and web thickness of 25mm with block density between 1100 kg/m3 and
1500 kg/m3 having a minimum average compressive strength not lessthan 3.5 N/mm2
confirming to IS 2185 (Part) : 2005 and constructed with CM 1:4 , as per IS 2572:2005 Sqm 904.00
including cost of all materials, labour charegs, scaffolding, curing complete as per
specifications. KBS No.5.4

Page No. 24
5.26.1 KSRB 5-11 : Providing and constructing load bearing wall with solid concrete blocks of
size 400x200x200 mm having block density not lessthan 1800 kg/m3 and having a minimum
average compressive strength 4.00 N/mm2 confirming to IS 2185 (Part) : 2005 and
constructed with CM 1:4 , as per IS 2572:2005 including cost of all materials, labour
Sqm 937.00
charegs, scaffolding, curing complete as per specifications. KBS No.5.4

5.26.2 KSRB 5-11 : Providing and constructing load bearing wall with solid concrete blocks of
size 400x150x200 mm having block density not lessthan 1800 kg/m3 and having a minimum
average compressive strength 4.00 N/mm2 confirming to IS 2185 (Part) : 2005 and Sqm 907.00
constructed with CM 1:4 , as per IS 2572:2005 including cost of all materials, labour
charegs, scaffolding, curing complete as per specifications. KBS No.5.4
5.27.1 KSRB 5-11 : Providing and constructing load bearing wall with solid concrete blocks of
size 400x200x200 mm having block density not lessthan 1800 kg/m3 and having a minimum
average compressive strength 5.00 N/mm2 confirming to IS 2185 (Part) : 2005 and Sqm 937.00
constructed with CM 1:4 , as per IS 2572:2005 including cost of all materials, labour
charegs, scaffolding, curing complete as per specifications. KBS No.5.4
5.27.2 KSRB 5-11 : Providing and constructing load bearing wall with solid concrete blocks of
size 400x150x200 mm having block density not lessthan 1800 kg/m3 and having a minimum
average compressive strength 5.00 N/mm2 confirming to IS 2185 (Part) : 2005 and sqm 831.00
constructed with CM 1:4 , as per IS 2572:2005 including cost of all materials, labour
charegs, scaffolding, curing complete as per specifications. KBS No.5.4
5.28 KSRB 5-11 : Providing and constructing non load bearing wall with solid concrete blocks
of size 400x100x200 mm having block density not lessthan 1800 kg/m3 and having a
minimum average compressive strength 4.00 N/mm2 confirming to IS 2185 (Part) : 2005
and constructed with CM 1:4 , as per IS 2572:2005 including cost of all materials, labour sqm 716.00
charegs, scaffolding, curing complete as per specifications. KBS No.5.4

5.29.1 Providing and fixing pre cast solid concrete kerb stones of size 450x200x400 mm made out
of CC 1:2:4 and finished with CM 1:3 plastering and finishing cutting ete., complete. no 364.00

5.29.2 Providing and fixing pre cast solid concrete kerb stones of size 450x150x500 mm made out
of CC 1:2:4 and finished with CM 1:3 plastering and finishing cutting ete., complete. no 353.00

Page 15 of 350
5.30 Providing and fixing pre cast solid cement concrete kerb stones made out of CC 1:2:4 with
top and bottom width 114 and 165 mm respectively, 400mm high and 450mm in length
finished with CM 1:3 plastering and finishing cutting including formwork, curing, including No 313.00
cost of materials, labour charges of machinery, loading and unloading, lead and lift,
transportation ete.,complete
5.31.1 Providing granite slabs of selected quality roughly dressed havinf a size of 7.5 cms thick and
Sqm 628.00
fixed in cement mortar (1:6) including fixing curing ete., complete.
5.31.2 Providing granite slabs of selected quality roughly dressed havinf a size of 10 cms thick and
Sqm 779.00
fixed in cement mortar (1:6) including fixing curing ete., complete.
5.32 Removing B.S slab of drain and stacking Sqm 62.00
5.33 Removing and refixing stone slabs of drains and pointing in CM (1:3) Sqm 76.00

Page No. 25

6.0 6.BRICK WORK

6.1 KSRB 6-1.1 :Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 3.5 Newton per sqmm with mud
mortar for basement and superstructure including cost of materials, labour charges, Cum 5114.00
scaffolding, curing complete as per specifications Specification No. KBS 6.2.
6.2 KSRB 6-1.2 : Providing and constructing burnt brick masonry for basement and
superstructure with approved quality of non-modular bricks of standard size of class
designation 3.5Newton per sqmm with cement mortar1:8 including cost of materials, Cum 6141.00
labour charges, scaffolding, curing complete as per specifications. Specification No. KBS
6.2
6.3 KSRB 6-1.3 : Providing and constructing burnt brick masonry for basement and
superstructure with approved quality of non-modular bricks of standard size of class
designation 3.5Newton per sqmm with cement mortar1:6 including cost of materials, Cum 6269.00
labour charges, scaffolding, curing complete as per specifications. Specification No. KBS
6.2
6.5 KSRB 6-2.2 : Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 5.0Newton per sqmm (table
moulded) with cement mortar 1:8 for basement and superstructu/re including cost of Cum 6532.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2
6.6 KSRB 6-2.3 : Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 5.0Newton per sqmm (table
moulded) with cement mortar 1:6 for basement and superstructu/re including cost of Cum 6685.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2
6.7 KSRB 6-2.4 : Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 5.0 Newton per sqmm with cement
mortar 1:4 for basement and superstructure including cost of materials, labour charges, Cum 6963.00
scaffolding, curing complete as per specifications. Specification No. KBS 6.2. (P.No.27,
I.No. 6.7 of PWD SR 2015-16)
6.8 KSRB 6-3.1 : Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 7.5Newton per sqmm with cement
mortar 1:8 for basement and superstructure (Machine moulded Wirecut bricks) with cost of Cum 9918.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2
6.9 KSRB 6-3.2 : Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 7.5Newton per sqmm with cement
mortar 1:6 for basement and superstructure (Machine moulded Wirecut bricks) with cost of Cum 10046.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2

Page 16 of 350
6.10 KSRB 6-3.3 : Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 7.5Newton per sqmm with cement
mortar 1:4 for basement and superstructure (Machine moulded Wirecut bricks) with cost of Cum 10325.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2
6.11 KSRB 6-3.4 : Providing and constructing burnt brick masonry with approved quality of non-
modular bricks of standard size of class designation 7.5Newton per sqmm with cement
mortar 1:3 for basement and superstructure (Machine moulded Wirecut bricks) with cost of Cum 10603.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2

Page No. 27
6.13 KSRB 6-4.2 : Providing and constructing burnt brick masonry with approved quality of
modular bricks ground moulded of standard size of class designation 3.5Newton per
sqmm with cement mortar 1:8 for basement and superstructure with cost of materials, Cum 5794.00
labour charges, scaffolding, curing complete as per specifications. Specification No. KBS
6.2
6.14 KSRB 6-4.3 : Providing and constructing burnt brick masonry with approved quality of
modular bricks ground moulded of standard size of class designation 3.5Newton per
sqmm with cement mortar 1:6 for basement and superstructure with cost of materials, Cum 5906.00
labour charges, scaffolding, curing complete as per specifications. Specification No. KBS
6.2
6.16 KSRB 6-5.2 : Providing and constructing burnt brick masonry with approved quality of
modular bricks of standard size of class designation 5.0Newton per sqmm (table
moulded) with cement mortar 1:8 for basement and superstructure including cost of Cum 6430.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2
6.17 KSRB 6-5.3 : Providing and constructing burnt brick masonry with approved quality of
modular bricks of standard size of class designation 5.0Newton per sqmm (table
moulded) with cement mortar 1:6 for basement and superstructure including cost of Cum 6543.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2
6.18 KSRB 6-5.4 : Providing and constructing burnt brick masonry with approved quality of
modular bricks of standard size of class designation 5.0Newton per sqmm (table
moulded) with cement mortar 1:4 for basement and superstructure including cost of Cum 6786.00
materials, labour charges, scaffolding, curing complete as per specifications. Specification
No. KBS 6.2
6.19 KSRB 6-6.1 : Providing and constructing burnt brick masonry with approved quality of
modular bricks of standard size of class designation 7.5Newton per sqmm (Machine
moulded Wirecut bricks) with cement mortar 1:8 for basement and superstructure including Cum 10249.00
cost of materials, labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2
6.20 KSRB 6-6.2 : Providing and constructing burnt brick masonry with approved quality of
modular bricks of standard size of class designation 7.5Newton per sqmm (Machine
moulded Wirecut bricks) with cement mortar 1:6 for basement and superstructure including Cum 10362.00
cost of materials, labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2
6.21 KSRB 6-6.3 : Providing and constructing burnt brick masonry with approved quality of
modular bricks of standard size of class designation 7.5Newton per sqmm (Machine
moulded Wirecut bricks) with cement mortar 1:4 for basement and superstructure including Cum 10605.00
cost of materials, labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2
6.22 KSRB 6-6.4 : Providing and constructing burnt brick masonry with approved quality of
modular bricks of standard size of class designation 7.5Newton per sqmm (Machine
moulded Wirecut bricks) with cement mortar 1:3 for basement and superstructure including Cum 10849.00
cost of materials, labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2

Page 17 of 350
6.23 KSRB 6-7.1 : Construction of partition wall 11.2 cms thick with non modular ground
moulded burnt bricks of class designation 3.5 Newton per sqmm with cement mortar 1:4
inlcuding providing and fixing plaster mesh manufactured out of hot dipped galvanised iron
of nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c Sqm 858.00
including cost of materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2. (P.No. 28, I.No. 6.23 of PWD SR 2015-16)

6.24 KSRB 6-7.2 : Construction of partition wall 11.2 cms thick with non modular ground
moulded burnt bricks of class designation 5.0 Newton per sqmm with cement mortar 1:4
inlcuding providing and fixing plaster mesh manufactured out of hot dipped galvanised iron
of nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c Sqm 933.00
including cost of materials, labour charges, scaffolding, curing complete as per
specifications. Specification No. KBS 6.2

6.25 KSRB 6-7.3 : Construction of partition wall 11.2 cms thick with non-modular ground
moulded burnt bricks of class designation 3.5 Newton per sqmm with cement mortar 1:4
including cost of materials, labour charges, scaffolding, curing complete as per Sqm 834.00
specifications. Specification No. KBS 6.2
Page No. 28
6.26 KSRB 6-7.4 : Construction of partition wall 11.2 cms thick with non-modular ground
moulded burnt bricks of class designation 5.0 Newton per sqmm with cement mortar 1:4
including cost of materials, labour charges, scaffolding, curing complete as per Sqm 891.00
specifications. Specification No. KBS 6.2
6.27 KSRB 6-8.1 :Construction of partition wall 10 cms thick with ground moulded modular
burnt bricks of class designation 3.5 Newton per sqmm with cement mortar 1:4 including
providing and fixing plaster mesh manufactured out of hot dipped gelvanised iron of
nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including Sqm 719.00
cost of materials, labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2

6.28 KSRB 6-8.2 : Construction of partition wall 10 cms thick with table moulded modular
burnt bricks of class designation 5.0Newton per sqmm with cement mortar 1:4 including
providing and fixing plaster mesh manufactured out of hot dipped gelvanised iron of
nominal thickness 0.35 mm. 100 mm. wide as per I.S. 2212/1991 at 7.5 m. c to c including Sqm 788.00
cost of materials, labour charges, scaffolding, curing complete as per specifications.
Specification No. KBS 6.2

6.29 KSRB 6-8.3 :Construction of partition wall 10 cms thick with ground moulded modular
burnt bricks of class designation 3.5Newton per sqmm with cement mortar 1:4 including
cost of materials, labour charges, scaffolding, curing complete as per specifications. Sqm 732.00
Specification No. KBS 6.2
6.30 KSRB 6-8.4 : Construction of partition wall 10 cms thick with table moulded modular
burnt bricks of class designation 5.0 Newton per sqmm with cement mortar 1:4 including
cost of materials, labour charges, scaffolding, curing complete as per specifications. Sqm 746.00
Specification No. KBS 6.2
6.31 Providing and constructing approved quality of standard size precast FLY ASH brick
masonry with compresive strength not less than 3.5 Newton per sqmm with cement mortar
1:6 for basement and superstructure with cost of materials, labour charges, scaffolding, Cum 5370.00
curing complete as per specifications
6.32.1 Provinding and constructing non load bearing wall with Light Weight Concrete (Autoclaved
areated concrete) Blocks confirming to IS:2185 (part-3) 1984 and IS 6441-1972 of
compressive strength of 3.0N/sq mm with a thin layer of polymer based jointing solvent for
super structure with neccesary scaffolding, curing including cost of all materials, labour, Sqm 1055.00
lead& lift etc, complete as per specifications. - with 600x200x100mm size Blocks

6.32.2 Provinding and constructing non load bearing wall with Light Weight Concrete (Autoclaved
areated concrete) Blocks confirming to IS:2185 (part-3) 1984 and IS 6441-1972 of
compressive strength of 3.0N/sq mm with a thin layer of polymer based jointing solvent for
super structure with neccesary scaffolding, curing including cost of all materials, labour, Sqm 1503.00
lead& lift etc, complete as per specifications. - with 600x200x150mm size Blocks

Page 18 of 350
6.32.3 Provinding and constructing non load bearing wall with Light Weight Concrete (Autoclaved
areated concrete) Blocks confirming to IS:2185 (part-3) 1984 and IS 6441-1972 of
compressive strength of 3.0N/sq mm with a thin layer of polymer based jointing solvent for
super structure with neccesary scaffolding, curing including cost of all materials, labour, Sqm 1727.00
lead& lift etc, complete as per specifications. - with 600x200x200mm size Blocks

6.32.4 Provinding and constructing non load bearing wall with Light Weight Concrete (Autoclaved
areated concrete) Blocks confirming to IS:2185 (part-3) 1984 and IS 6441-1972 of
compressive strength of 3.0N/sq mm with a thin layer of polymer based jointing solvent for
super structure with neccesary scaffolding, curing including cost of all materials, labour, Sqm 1895.00
lead& lift etc, complete as per specifications. - with 600x200x230mm size Blocks

Page No. 29

7.0 7.STEEL AND ALUMINIUM WORK

7.1 KSRB 7.1 : Providing and fixing in position collapsible steel shutters with single or double
leaf with vertical channel 20mmx10mmx2mm braced with flat iron diagonals 20mmx5mm
size, with top and bottom rails of T iron sections of 40x40x6 mm with 38mm dia steel
pulleys complete with bolt and nuts, locking arrangements, stoppers, handles on both sides Sqm 4033.00
with 7.5cms openings at 10 cms. c to c applying a priming coat of red lead paint. cost of
materials, labour, HOM of machinery complete as per specifications. size of gate
2.4mx1.4m. Specification No. KBS 7.7 / 7.12

7.2 KSRB 7.2 : Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and
diagonal braces of 40x40x6 mm angle Iron 3.15mm thick M.S. Gusset plates at junctions
and corners, 25mm dia pulley, 40x40x6 mm angles and T iron guide rail top and bottom
respectively with handles, stoppers and locking arrangements etc., including applying a Sqm 2830.00
priming coat of red lead paint cost of materials, labour, HOM of machinery complete as per
specifications. 1 double leaf door of size 2.4x2.4m. Specification No. KBS 7.8 / 7.12

7.3 KSRB 7.3 : Providing and fixing 1mm thick M.S. sheet garage door with frame and
diagonal braces of size 40x40x6 mm angle Iron, 3.15mm thick M.S. Gusset plates at the
junctions and corners, with handles, stoppers and locking arrangements etc., including
applying a priming coat of red lead paint cost of materials, labour, HOM of machinery Sqm 2332.00
complete as per specifications. Double leaf door of size 2.4x2.4m. Specification No. KBS
7.9 / 7.12. (P.No. 31, I.No. 7.3 of CSR 2015-16)

7.4 KSRB 7.4 : Providing and fixing 1mm thick M.S. sheet garage door with frame and
diagonal braces of size 40x40x6 mm angle Iron, using M.S. flats 30x6 mm for diagonal
braces and central cross pieces 3.15mm thick M.S. Gusset plates at the junctions and
corners, with handles, stoppers and locking arrangements etc., including applying a priming Sqm 1911.00
coat of red lead paint cost of materials, labour, HOM of machinery complete as per
specifications. 1 double leaf door of size 2.4x2.4m. Specification No. KBS 7.9 / 7.12.
(P.No. 31, I.No. 7.4 of CSR 2015-16)

7.5 KSRB 7.5 : Providing and fixing pull and push type rolling shutters of approved make out
of 18 guage, 75mm wide cold rolled steel laths of convex corrugation, with side guides and
bottom rail, with interlocking arrangements for steel laths by means of alternate clips,
suspension shaft with High tension coil type springs two numbers, mounted on specially
designed pipe shaft, with bracket plates, guide channels, ball bearing arrangements, for
inside & outside locking with push & pull operations complete including pulling hooks, Sqm 2862.00
4Nos. handles with all fittings and accessories, painted with a coat of red lead paint (without
top cover) cost of materials, labour, HOM of machinery complete as per specifications.
Shutter size 3mx2.8 m. Specification No. KBS 7.10 / 7.12. (P.No. 31, I.No. 7.5 of CSR
2015-16)

Page No. 31
7.6 KSRB 7.6 : Providing and fixing top covers made out of 20 guage M.S. sheet over pull and
push rolling shutters bent to shape including cost of red lead primer coat of painting ,
materials, labour, HOM of machinery complete as per specifications. Specification No. KBS m 473.00
7.10.6 / 7.12

Page 19 of 350
7.7 KSRB 7.7 : Providing and fixing in position in cement concrete 1:3:6 steel glazed windows
and ventilators side hung/top hung fully openable as per approved drawings using Z
angles of 25x33x3mm, weighing 1.419 Kg/m both for outer and inner frames and central
mullion section of size 25x46x3mm. weighing 2.28Kg/m duly providing T section
19x19x3mm weighing 0.839 kg/m for glazing of windows not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood beading of required
size, all steel sections should confirm to I.S 7452:1990, 4nos. of holdfasts of approved size,
section should be cut to length welded and electrically grinded subdividing frames of unit Sqm 3530.00
shall be tenonned and revetted into the frames electrically. All the steel surface shall be
throughly cleaned free of rust and painted with one coat of anti-corosive paint and finishing
with two coats of ready mix paint of approved colour and make including cost of materials,
fixtures, labour and HOM of machinerycomplete as per specifications. Specification No.
KBS 7.12.1 / 7.12.2 / 7.12.3 / 7.12

7.8 KSRB 7.8 : Providing and fixing in position in cement concrete 1:3:6 steel glazed windows
and ventilators side hung/top hung 2/3 openable 1/3 fixed as per approved drawings using Z
angles of 25x33x3mm, weighing 1.419 kg/m both for outer and inner frames and central
mullion section of size 25x46x3mm, weighing 2.28kg/m all duly providing T section
19x19x3mm weighing 0.839 kg/m for glazing of windows, not more than 34 cms. c to c
including providing and fixing 4mm. thick reeded glass with teakwood beading of required
size, all steel sections should confirm to I.S 7452:1990, 4nos. of holdfasts of approved size,
section should be cut to length welded and grinded electrically subdividing frames of unit Sqm 2975.00
shall be tenonned and revetted into the frames electrically. All the steel surface shall be
throughly cleaned free of rust and painted with one coat of anti-corrosive paint and finishing
two coats of ready mix paint of approved colour and make including cost of materials,
fixtures, labour charges and HOM of machinery complete as per specifications.

7.9 KSRB 7.9 : Providing and fixing M.S.grill work for windows and ventilators weighing
21kg/sqm using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods
as per approved design, drawing including cutting steel sections and welding the same to
required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM Kgs 78.00
of machinery complete as per specifications. Specification No. KBS 7.12. (P.No. 32, I.No.
7.9 of PWD SR 2015-16)
Page No. 32
7.10.1 KSRB 7.10 : Providing and fixing in position aluminium windows and ventilators as per
approved drawings with sliding shutters using double track window frame section of size
61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top
sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of
size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm,
1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick,
weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures
such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain
glass for shutters fitted with rubber beading aluminium sections including cutting to required Sqm 3818.00
length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame
stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills
as the case may be with necessary steel screws, raul plugs, or teak wood gatties including
cutting masonry or concrete and making good the original surface using cement mortar,
aluminium sections pretreated for removal of any Specification No. KBS
using aluminium section anodized to 12 - 15 microns.

Page 20 of 350
7.10.2 KSRB 7.10 : Providing and fixing in position aluminium windows and ventilators as per
approved drawings with sliding shutters using double track window frame section of size
61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top
sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of
size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm,
1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick,
weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures
such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain
glass for shutters fitted with rubber beading aluminium sections including cutting to required
length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame
stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills
as the case may be with necessary steel screws, raul plugs, or teak wood gatties including Sqm 3898.00
cutting masonry or concrete and making good the original surface using cement mortar,
aluminium sections pretreated for removal of any Specification No. KBS
using aluminium section powdered coated to a minimum of 60-70 microns with exterior
durable pure polyester grade powder of approved quality. (P.No. 33, I.No. 7.10.2 of PWD
SR 2015-16)

7.11.1 KSRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per
approved drawings with sliding shutters using three track window frame of size
92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm,
thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size
40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm.
wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall
thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with
approved quality of fixtures such as aluminium handles tower bolts etc.; providing and
fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections Sqm 4091.00
including cutting to required length, joints mitred subdividing the frame tenonned and
rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to
the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul
plugs or teak wood gatties including cutting masonry or concrete and making good the
original surface using cement mortar.
using aluminium section anodized to 12 - 15 microns.

7.11.2 KSRB 7.11 : Providing and fixing in position aluminium windows and ventilators as per
approved drawings with sliding shutters using three track window frame of size
92x31.75mm bottom section 1.3mm thick, weight 1.07kg/m; sides and top sections 1.3 mm,
thick, weight 0.933 kg/m.shutter frame section comprising top and bottom section of size
40mmx18mm, wall thickness 1.25mm. weight 0.417 kg./m. shutter side outer 40mmx18mm.
wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall
thickness 1.1 mm. thick, weight 0.469 kg/m, the shutters mounted on nylon rollers with
approved quality of fixtures such as aluminium handles tower bolts etc.; providing and
fixing 5.5mm. thick plain glass for shutters fitted with rubber beading all aluminium sections
including cutting to required length, joints mitred subdividing the frame tenonned and
rivetted, in the assembled frame, stiffened with end clips for corners, angles etc., and fixed to Sqm 4181.00
the walls, lintels, floor beams/cills as the case may be, with necessary steel screws, raul
plugs or teak wood gatties including cutting masonry or concrete and making good the
original surface using cement mortar.
using aluminium section powdered coated to a minimum of 60-70 microns with exterior
durable pure polyester grade powder of approved quality. (P.No. 33, I.No. 7.11.2 of PWD
SR 2015-16)

Page No. 33

Page 21 of 350
7.12.1 KSRB 7.12 : Providing and fixing in position aluminium windows and ventilators as per
approved drawings with sliding shutters using four track window frame of size
122.2x31.75mm. for bottom section 1.1mm thick, weight 1.205 kg/m; sides and top sections
1.2 mm. thick weight 1.093 kg/m; shutter section comprising top and bottom section of size
40mmx18mm wall thickness 1.25mm. weight 0.417 kg./m, shutter sideouter 40mmx18mm.
wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall
thickness 1.1 mm. weight 0.469 kg/m; shutters mounted on nylon rollers with approved
quality of fixtures such as aluminium handles, tower bolts etc.; providing and fixing 5.5mm.
thick plain glass for shutters fitted with rubber beading including cutting to required length, Sqm 3558.00
joints mitred subdividing the frame, tenonned and rivetted in the assembled frame to be
stiffened with end clips at corners, angles etc.; fixed to the walls, lintels, floor beams;cills, as
the case may be with necessary steel screws, raul plugs, or teak wood gatties including
cutting masonry or concrete and making good the original surface using cement mortar;
aluminium sections pretreated for removal of any rust and coated with greasy materials for
non adhesion of mortar and other sticky materials; ( this coating should be cleaned after
installation ) including cost of materials, fixtures, labour and HOM of machinery complete
as per specifications.
7.12.2 using aluminium
KSRB section and
7.12 : Providing anodized
fixingtoin12position
- 15 microns.
aluminium windows and ventilators as per
approved drawings with sliding shutters using four track window frame of size
122.2x31.75mm. for bottom section 1.1mm thick, weight 1.205 kg/m; sides and top sections
1.2 mm. thick weight 1.093 kg/m; shutter section comprising top and bottom section of size
40mmx18mm wall thickness 1.25mm. weight 0.417 kg./m, shutter sideouter 40mmx18mm.
wall thickness 1.25mm. weight 0.417 kg/m, shutter interlock section 40mmx26.7mm wall
thickness 1.1 mm. weight 0.469 kg/m; shutters mounted on nylon rollers with approved
quality of fixtures such as aluminium handles, tower bolts etc.; providing and fixing 5.5mm.
thick plain glass for shutters fitted with rubber beading including cutting to required length, Sqm 3657.00
joints mitred subdividing the frame, tenonned and rivetted in the assembled frame to be
stiffened with end clips at corners, angles etc.; fixed to the walls, lintels, floor beams;cills, as
the case may be with necessary steel screws, raul plugs, or teak wood gatties including
cutting masonry or concrete and making good the original surface using cement mortar;
aluminium sections pretreated for removal of any rust and coated with greasy materials for
non adhesion of mortar and other sticky materials; ( this coating should be cleaned after
installation ) including cost of materials, fixtures, labour and HOM of machinery complete
as per specifications.
7.13.1 using 7.13
KSRB aluminium sectionand
: Providing powdered coated to acasement
fixing aluminium minimumwindows,
of 60-70 microns with of
combination exterior
fixed
glazing at top fully openable windows using Z sections of 33mm, web thickness 4mm,
weight 0.663 kg/m; central mullion section 59x33mm with web thickness 3mm section
weight 1.123kg/m; the shutters on aluminium hinges with approved quality of fixtures such
as aluminium tower bolts, handles, stays etc., providing and fixing 5.5mm plain glass for
shutters fitted with glazed clips 19mmx17.3mmx11mm. 0.9mm thick and rubber beading,
aluminium sections cutting to required length, joints metered, subdividing the frame
tennoned and rivetted, assembled frame to be stiffened with end clips at corner, angles and
fixed to wall, lintel beam, floor;cill, as the case may be with necessary screws, rawl plugs, Sqm 4494.00
cutting masonry or concrete and making good the orginal surface; aluminium surface
pretreated for removal of any rust and coated with greasy materials for nonadherence of
mortar or any other sticky materials; (coating removed after instalation) and throughly
cleaned free from dirt, rust etc., including cost of materials, fixtures, labour and HOM of
machinery complete as per specifications.
using aluminium section anodized to 12 - 15 microns.

Page 22 of 350
7.13.2 KSRB 7.13 : Providing and fixing aluminium casement windows, combination of fixed
glazing at top fully openable windows using Z sections of 33mm, web thickness 4mm,
weight 0.663 kg/m; central mullion section 59x33mm with web thickness 3mm section
weight 1.123kg/m; the shutters on aluminium hinges with approved quality of fixtures such
as aluminium tower bolts, handles, stays etc., providing and fixing 5.5mm plain glass for
shutters fitted with glazed clips 19mmx17.3mmx11mm. 0.9mm thick and rubber beading,
aluminium sections cutting to required length, joints metered, subdividing the frame
tennoned and rivetted, assembled frame to be stiffened with end clips at corner, angles and
fixed to wall, lintel beam, floor;cill, as the case may be with necessary screws, rawl plugs, Sqm 4579.00
cutting masonry or concrete and making good the orginal surface; aluminium surface
pretreated for removal of any rust and coated with greasy materials for nonadherence of
mortar or any other sticky materials; (coating removed after instalation) and throughly
cleaned free from dirt, rust etc., including cost of materials, fixtures, labour and HOM of
machinery complete as per specifications.
using aluminium section powdered coated to a minimum of 60-70 microns with exterior
durable pure polyester grade powder of approved quality.

Page No.34
7.14.1 KSRB 7.14 : Providing, fabricating, assembling and fixing in position aluminium partitions
using sections in combination of plain, single grove and double grove as per requirements
for the frames of overall size 101.6mm x 44.45mm, 3.18mm.thick having section weight,
plain sections 2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683
kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm 1.7mm. thick
section weight 0.483kg/m; bottom portions provided with 12mm. thick prelaminated sheet
both side of approved colour lamination exterior grade; aluminium sections of mat finish or
glossy finish using section, spacing of vertical member shall not exceed 0.6 m. c to c;
sections are cut to the required lengths, joints mitered and corners grinded subdividing
frames tennoned and rivetted to the frames, the assembled frame should be stiffened with
corner angles stripped and fixed with screws, rawl plugs and teak wood gutties to
R.C.C.columns or masonry on sides, R.C.C. lintels or beams at top and floor at bottom,
including cutting chistling and making good with cement mortar to match the surface,
providing and fixing bottom panel filled with the materials to a height of 0.9m. from floor
level; and 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel
with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm. with Sqm 4658.00
thickness of 0.9mm. weight 0.124kg/m; aluminium sections pre-treated for removal of any
rust and prevention of further rust formation, and coated with greasy materials for non-
adherence of mortars or any other sticky materials; vertical members embedded in the
flooring by making suitable size holes and fixing with cement mortar, with necessary
opening for fixing of doors of standard size (excluding cost of door opening) All the frame
should be throughly cleaned free from rust, scale or dirt including cost of materials, fixtures,
labour and HOM of machinery complete as per specifications.
using aluminium section anodized to 12 - 15 microns. (P.No. 35, I.No. 7.14.1 of PWD SR
2015-16)

Page 23 of 350
7.14.2 KSRB 7.14 : Providing, fabricating, assembling and fixing in position aluminium partitions
using sections in combination of plain, single grove and double grove as per requirements
for the frames of overall size 101.6mm x 44.45mm, 3.18mm.thick having section weight,
plain sections 2.40kg/m single grove section 2.541kg/m. and double grovesection 2.683
kg/m and bottom 46 kg/m; aluminium louvres of size 77.6mmx27.6mm 1.7mm. thick
section weight 0.483kg/m; bottom portions provided with 12mm. thick prelaminated sheet
both side of approved colour lamination exterior grade; aluminium sections of mat finish or
glossy finish using section, spacing of vertical member shall not exceed 0.6 m. c to c;
sections are cut to the required lengths, joints mitered and corners grinded subdividing
frames tennoned and rivetted to the frames, the assembled frame should be stiffened with
corner angles stripped and fixed with screws, rawl plugs and teak wood gutties to
R.C.C.columns or masonry on sides, R.C.C. lintels or beams at top and floor at bottom,
including cutting chistling and making good with cement mortar to match the surface,
providing and fixing bottom panel filled with the materials to a height of 0.9m. from floor
level; and 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel
with lower sections, the glass and panels fitted with glazing clips of 19mmx17.3mm. with
Sqm 4731.00
thickness of 0.9mm. weight 0.124kg/m; aluminium sections pre-treated for removal of any
rust and prevention of further rust formation, and coated with greasy materials for non-
adherence of mortars or any other sticky materials; vertical members embedded in the
flooring by making suitable size holes and fixing with cement mortar, with necessary
opening for fixing of doors of standard size (excluding cost of door opening) All the frame
should be throughly cleaned free from rust, scale or dirt including cost of materials, fixtures,
labour and HOM of machinery complete as per specifications.
using aluminium section powdered coated to a minimum of 60-70 microns with exterior
durable pure polyester grade powder of approved quality. ((P.No.35/I.No. 7.14.2 of CSR
2015-16)

Page No. 35
7.15.1 KSRB 7.15 : Providing, fabricating, assembling and fixing in position aluminium partitions
using aluminium sections of mat finish or glassy finish in combination of plain grove, single
grove and double grove as per requirements for the frames of overall size 63.5mm x
38.1mm. with thickness of 2mm. having section weight, plain sections 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094kg/m, double grove thickness 1.9mm section
weight 1.094kg/m and bottom member 114.3 mm. x 44.45mm. thickness 3.18mm. weight
2.646 kg/m; aluminium louvres section of size 36.5mmx34.93mm 1.45mm. thick section
weight 0.429kg/m; bottom portions provided with 12mm. thick prelaminated sheet both
sides of approved colour lamination exterior grade upto 0.9m height, spacing of vertical
member not exceeding 0.6 m. c to c; sections are cut to the required lengths, joints mitered
and corners grinded subdividing frames tennoned and rivetted to the frames; the assembled
frame stiffened with corner angles, stripped and fixed with screws, rawl plugs and teak wood
gutties to R.C.C.columns on sides, R.C.C. lintels or beams at top and floor at bottom,
including cutting chistelling and making good with cement mortar to match the surface;
providing and fixing 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and
top panel with louvres sections; the glass and panels fitted withglazing clips of Sqm 3234.00
19mmx17.3mm. of thickness 0.9mm. weight 0.124kg/ m, aluminium sections treated for
removal of any rust and prevention of further rust formation, coated with greasy materials
for non-adherence of mortars or any other sticky materials; vertical members embedded in
the flooring by making suitable sized holes and fixing with cement mortar, with necessary
opening for fixing of door of standard size (excluding cost of door ) all the frame throughly
cleaned, free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of
machinery complete as per specifications.
using aluminium section anodized to 12 - 15 microns.

Page 24 of 350
7.15.2 KSRB 7.15 : Providing, fabricating, assembling and fixing in position aluminium partitions
using aluminium sections of mat finish or glassy finish in combination of plain grove, single
grove and double grove as per requirements for the frames of overall size 63.5mm x
38.1mm. with thickness of 2mm. having section weight, plain sections 1.054kg/m, single
grove thickness 1.95mm. section weight 1.094kg/m, double grove thickness 1.9mm section
weight 1.094kg/m and bottom member 114.3 mm. x 44.45mm. thickness 3.18mm. weight
2.646 kg/m; aluminium louvres section of size 36.5mmx34.93mm 1.45mm. thick section
weight 0.429kg/m; bottom portions provided with 12mm. thick prelaminated sheet both
sides of approved colour lamination exterior grade upto 0.9m height, spacing of vertical
member not exceeding 0.6 m. c to c; sections are cut to the required lengths, joints mitered
and corners grinded subdividing frames tennoned and rivetted to the frames; the assembled
frame stiffened with corner angles, stripped and fixed with screws, rawl plugs and teak wood
gutties to R.C.C.columns on sides, R.C.C. lintels or beams at top and floor at bottom,
including cutting chistelling and making good with cement mortar to match the surface;
providing and fixing 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and
top panel with louvres sections; the glass and panels fitted withglazing clips of Sqm 3302.00
19mmx17.3mm. of thickness 0.9mm. weight 0.124kg/ m, aluminium sections treated for
removal of any rust and prevention of further rust formation, coated with greasy materials
for non-adherence of mortars or any other sticky materials; vertical members embedded in
the flooring by making suitable sized holes and fixing with cement mortar, with necessary
opening for fixing of door of standard size (excluding cost of door ) all the frame throughly
cleaned, free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of
machinery complete as per specifications.
using aluminium section powdered coated to a minimum of 60-70 microns with exterior
durable pure polyester grade powder of approved quality.

7.16.1 KSRB 7.16 : Providing, fabricating, assembling and fixing in position aluminium shutters to
the existing door frame in the partition using 47.62x44.45mm section thickness 3.18mm,
weight 1.505kg/m for vertical frame; 47.62x44.45 thickness of 3mm, weight 1.42kg/m for
top section, 49.91mmx44.45mm with wall thickness 3mm, weight 1.495kg/ m for central
rail; and 114.3mmx44.45mm thickness 3.18mm, weight 2.646kg/m for bottom rail;
aluminium sections and cut to length joint metred and corners grinded, the bottom rail and
top rail hinged or pivoted, opening arrangements including providing and fixing standard
approved accessories, such as aluminium handles, tower bolts, lock, pivots: hinges P.V.C. or
rubber gasket, 12mm prelaminated sheets ( Novopan) exterior grade of approved colour both Sqm 3973.00
sides same colour for bottom panel of maximum height 0.90m and 5.5mm thick plain glass
for top panel ( Novopan ) and glass fixed with glazed clips 19mmx17.3mmx11mm, 0.9mm
thick, weight 0.124kg/m; aluminium sections treated for removal of any rust and prevention
of further rust formation, and coated with greasy materials for non-adherance of mortars or
any other sticky materials, including cost of materials, fixtures, labour and HOM of
machinery complete as per specifications.
using aluminium section anodized to 12 - 15 microns.

7.16.2 KSRB 7.16 : Providing, fabricating, assembling and fixing in position aluminium shutters to
the existing door frame in the partition using 47.62x44.45mm section thickness 3.18mm,
weight 1.505kg/m for vertical frame; 47.62x44.45 thickness of 3mm, weight 1.42kg/m for
top section, 49.91mmx44.45mm with wall thickness 3mm, weight 1.495kg/ m for central
rail; and 114.3mmx44.45mm thickness 3.18mm, weight 2.646kg/m for bottom rail;
aluminium sections and cut to length joint metred and corners grinded, the bottom rail and
top rail hinged or pivoted, opening arrangements including providing and fixing standard
approved accessories, such as aluminium handles, tower bolts, lock, pivots: hinges P.V.C. or
rubber gasket, 12mm prelaminated sheets ( Novopan) exterior grade of approved colour both Sqm 4014.00
sides same colour for bottom panel of maximum height 0.90m and 5.5mm thick plain glass
for top panel ( Novopan ) and glass fixed with glazed clips 19mmx17.3mmx11mm, 0.9mm
thick, weight 0.124kg/m; aluminium sections treated for removal of any rust and prevention
of further rust formation, and coated with greasy materials for non-adherance of mortars or
any other sticky materials, including cost of materials, fixtures, labour and HOM of
machinery complete as per specifications.
using aluminium section powdered coated to a minimum of 60-70 microns with exterior
durable pure polyester grade powder of approved quality. (P.No. 36, I.No. 7.16.2 of PWD
SR 2015-16) Page No. 36

Page 25 of 350
7.17.1 KSRB 7.17 : Providing, fabricating, assembling and fixing in position aluminium doors
using following aluminium mat finish or glossy finish, outer frame plain section
101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section
44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm
thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness
3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm,
section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight
0.124kg/m; aluminium sections cut to length joint metred cornersgrinded, the shutters
pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor Sqm 6221.00
mounted, providing and fixing standard approved accessories, such as aluminium handle for
full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain
glass for top and bottom panel; aluminium sections treated for removal of any rust and
prevention of further rust formation, and coated with greasy materials for non-adherance of
mortars or any other sticky materials; the assembled frame fitted with the corner angles,
strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry
on sides. beams and flooring in bottom. including cutting, chistling and making good with
cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or
7.17.2 dirt
KSRB including
7.17 : cost of materials,
Providing, fixtures,
fabricating, labour and
assembling andHOM
fixingofinmachinery complete as
position aluminium per
doors
using following aluminium mat finish or glossy finish, outer frame plain section
101.6x44.45mm thickness 3.18mm, section weight 2.404 kg/m, door shutters vertical section
44.62x44.45mm thickness 3.18mm, section weight 1.505kg/m, top section 47.62x44.45mm
thickness 3.00mm, section weight 1.426kg/m bottom section 114.3x44.45 thickness
3.18mm, section weight 2.646kg/m, door central section 49.91x44.45mm thickness 3.00mm,
section weight 1.495 kg/m glazing clips 19x17.3x11mm thickness 0.9mm section weight
0.124kg/m; aluminium sections cut to length joint metred cornersgrinded, the shutters
pivoted opening arrangement with heavy duty aluminium alloy automatic door closures floor Sqm 6310.00
mounted, providing and fixing standard approved accessories, such as aluminium handle for
full width or length, tower bolts, lock, pivots: P.V.C. or rubber gasket with 5.5m. thick plain
glass for top and bottom panel; aluminium sections treated for removal of any rust and
prevention of further rust formation, and coated with greasy materials for non-adherance of
mortars or any other sticky materials; the assembled frame fitted with the corner angles,
strips and fitted with screws, rawl plugs or teakwood gutties to R.C.C. columns or masonry
on sides. beams and flooring in bottom. including cutting, chistling and making good with
cement mortar to match the surface; all the frames throughly cleaned free from rust, scale, or
7.18 dirt including
Providing and cost
fixingofofmaterials,
Aluminium fixtures, labour
composite and of
panel HOM of machinery
approved make andcomplete
colour foraswall
per
cladding for straight Brick/Rcc/stone walls & coloumns/beams with necessary aluminium
frame works at required level made out of 50x25x3mm C section or equalent. The panel
should consist of 2.5 mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminium sheet making a total panel thickness of 3mm. The surfaces will be
finished with PVDF based coating on topsides and service coating on reverse sides would be
in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and Sqm 4501.00
stainless steel bolts and nuts complete with spring washer and cap nuts and all other
necessary accessories, sealing shall be done using weather sealant of Dow Corning 789 with
necessary rods etc., complete.

7.19 Providing and fixing of Aluminium composite panel of approved make and colour for wall
cladding for curved Brick/Rcc/stone walls & coloumns/beams with necessary aluminium
frame works at required level made out of 50x25x3mm C section or equalent. The panel
should consist of 2.5 mm thermoplastic core of antitoxic LDPE sandwiched between 0.25
skins thick aluminium sheet making a total panel thickness of 3mm. The surfaces will be
finished with PVDF based coating on topsides and service coating on reverse sides would be Sqm 5043.00
in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and
stainless steel bolts and nuts complete with spring washer and cap nuts and all other
necessary accessories, sealing shall be done using weather sealant necessary rods etc.,
complete.

7.20 Providing, fabricating and fixing of stick type structural glazing using Alluminium
Extrusions of 63.5 mm x 58.00 mmx 2.25 mm of 1.73 kgs/ mtr for vertical and Horizontal
members and 63.5 mm x 38.1 x 1.33 mm of 0.759 kg/Mtr, as outer frame with Electro
Anodized Paint coated block finishing, using 6mm thick imported glass reflective hard
coatedocean blue raw glass with all necessary accesories like ultra glass Silicon sealant of Sqm 5871.00
Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, 6mm thick M.S. angle
50mm x 150mm x 6mm M.S. Galvanized L Brackets, structural sealent setting clocks,
fasteners, wall connection etc., complete.

Page 26 of 350
Page No. 37
7.21.1 "Providing fusion bonded epoxy coating not less than 175 microns thickness and upto 300
microns to reinforcement of all diameters as per IS: 13620-1993 including testing of coating
at plant. The rate is inclusive of cost on account of careful handling, PVC coated binding
wire instead of GI Binding wire, touch up material supplied by coating agency, repair work,
loading, unloading and straightening of bent rods etc., complete as per specification and as
directed by the Engineer in charge. (Inclusive of all taxes but excluding transportation Tonne 11800.00
charges)
For 10mm to 16mm dia bars

7.21.2 "Providing fusion bonded epoxy coating not less than 175 microns thickness and upto 300
microns to reinforcement of all diameters as per IS: 13620-1993 including testing of coating
at plant. The rate is inclusive of cost on account of careful handling, PVC coated binding
wire instead of GI Binding wire, touch up material supplied by coating agency, repair work,
loading, unloading and straightening of bent rods etc., complete as per specification and as Tonne 8380.00
directed by the Engineer in charge. (Inclusive of all taxes but excluding transportation
charges)
For 20mm to 32mm dia bars

7.22.1 Providing , fabricating, assembling and fixing in position aluminium partition using
101.60mm x 44.45mm x 3.18mm aluminium, mat finish or glossy finish , anodized sections
combination of plain , single groove and double groove members should not exceed
0.60mc/c and bottom member of required lengths, joints mitred and corner grinded sub
dividing assembled frame should be stiffened with corner angles. Stripped and fixed with
screws rawl plug and teakwood guttas to RCC column or masonry on sides. RCC lintels or
beams at top and mosaic floor at bottom; including cutting chistelling and making good with
cement mortar to match the surface .Providing and fixing 12mm.thick prelaminated sheet
(Ecoboard – exterior grade )of approved colour for bottom panel of maximum height 0.9m,
and 5.50 mm thick plain or pin headed glass for middle panel and top panel with glazing
clips pf 19.05mm.x17.30mm.1.00mm. All the aluminium sections used should be treated for
removal of any rust and prevention of further rust formation and coated with greasy Sqm 2900.00
materials for non adherence of mortar or any other sticky materials: The vertical members
should be embedded in the flooring by making suitable size holes and fixing with cement
mortar. All the frame should be thoroughly cleaned free from rust , scale or dirt. work should
be carried out as per direction of engineer-in-charge of the work with all lead and lift as per
chief Architect’s drawing etc., complete to a degree of perfection.
using aluminium section anodized to 12 - 15 microns.

Page 27 of 350
7.22.2 Providing , fabricating, assembling and fixing in position aluminium partition using
101.60mm x 44.45mm x 3.18mm aluminium, mat finish or glossy finish , anodized sections
combination of plain , single groove and double groove members should not exceed
0.60mc/c and bottom member of required lengths, joints mitred and corner grinded sub
dividing assembled frame should be stiffened with corner angles. Stripped and fixed with
screws rawl plug and teakwood guttas to RCC column or masonry on sides. RCC lintels or
beams at top and mosaic floor at bottom; including cutting chistelling and making good with
cement mortar to match the surface .Providing and fixing 12mm.thick prelaminated sheet
(Ecoboard – exterior grade )of approved colour for bottom panel of maximum height 0.9m,
and 5.50 mm thick plain or pin headed glass for middle panel and top panel with glazing
clips pf 19.05mm.x17.30mm.1.00mm. All the aluminium sections used should be treated for
removal of any rust and prevention of further rust formation and coated with greasy
materials for non adherence of mortar or any other sticky materials: The vertical members Sqm 3000.00
should be embedded in the flooring by making suitable size holes and fixing with cement
mortar. All the frame should be thoroughly cleaned free from rust , scale or dirt. work should
be carried out as per direction of engineer-in-charge of the work with all lead and lift as per
chief Architect’s drawing etc., complete to a degree of perfection.
using aluminium section powdered coated to a minimum of 60-70 microns with exterior
durable pure polyester grade powder of approved quality.

7.23 Providing and fixing door frame with or without ventilator made out of cold rolled steel
section of thickness 1.25mm formed into section of 60mm x 105mm welded to form a
rectangular door conforming to IS 513-1973 and phosphated and painted and with one coat
of red oxideprimer, two coat of approved enamel paints the frame work with 4nos. of hold
fast of size 200 x 25 x 4mm fixed in cement concrete 1:3 :6 of 20mm down size jelly and
4nos. of ISI marked hinges 125mm long welded to the frame and fixed with shutter made
out of Honne wood styles and rails of 30mm thick with panels of 12mm thick ‘Ecoboard’ Sqm 2200.00
Plain Particle Board of exterior grade conforming to IS- 3087 excluding the cost of fixtures
but including labour charges for fixing of fixtures.. The hollow portion of the frame to be
filled with c.c1:2:4 of 20mm down size jelly.

Page No. 38
7.24.1.a "Providing and fixing cold rolled prepainted steel windows of IS standards, made out of
0.6mm thick deep drawing quality galvanised on both sides 120gms/sq.mtr. Primer coat upto
5 microns with thermosetting epoxy resin and finish painted with a polyester based paint 20
microns thick. The size of profiles is approximately 46 x 52mm for external frames,
46x46mm section for shutters, 46x70mm section for centre mullion/transom and 18x31mm
section is for fixing glasses. The section should be cut to length joint mitred and assembling
by means of corner brackets made out of cold rolled cold annealed strips of 1.2mm thick
duly galvanised and fixed with nickle plated self taping screws.The shutters are provided
with approved quality of fixtures like handles made out of zamac alloy die cast and powder Sqm 4689.00
coated, receiver made out of glass filled nylone and hinges made out of CRCA powder
coated. 4mm thick glass should be fixed with EPDM gaskets. Guard bars fabricated out of
10mm square bright bars shall be fixed horizontally at 125mm C/C by rivetting to the
external frame. The above frames are fixed to the concrete / masonry walls by means of self
expanding screws.”
with 4mm float glass without gaurd bars

Page 28 of 350
7.24.1.b "Providing and fixing cold rolled prepainted steel windows of IS standards, made out of
0.6mm thick deep drawing quality galvanised on both sides 120gms/sq.mtr. Primer coat upto
5 microns with thermosetting epoxy resin and finish painted with a polyester based paint 20
microns thick. The size of profiles is approximately 46 x 52mm for external frames,
46x46mm section for shutters, 46x70mm section for centre mullion/transom and 18x31mm
section is for fixing glasses. The section should be cut to length joint mitred and assembling
by means of corner brackets made out of cold rolled cold annealed strips of 1.2mm thick
duly galvanised and fixed with nickle plated self taping screws.The shutters are provided
with approved quality of fixtures like handles made out of zamac alloy die cast and powder Sqm 4873.00
coated, receiver made out of glass filled nylone and hinges made out of CRCA powder
coated. 4mm thick glass should be fixed with EPDM gaskets. Guard bars fabricated out of
10mm square bright bars shall be fixed horizontally at 125mm C/C by rivetting to the
external frame. The above frames are fixed to the concrete / masonry walls by means of self
expanding screws.”
with 4mm tinted glass without gaurd bars

7.24.1.c "Providing and fixing cold rolled prepainted steel windows of IS standards, made out of
0.6mm thick deep drawing quality galvanised on both sides 120gms/sq.mtr. Primer coat upto
5 microns with thermosetting epoxy resin and finish painted with a polyester based paint 20
microns thick. The size of profiles is approximately 46 x 52mm for external frames,
46x46mm section for shutters, 46x70mm section for centre mullion/transom and 18x31mm
section is for fixing glasses. The section should be cut to length joint mitred and assembling
by means of corner brackets made out of cold rolled cold annealed strips of 1.2mm thick
duly galvanised and fixed with nickle plated self taping screws.The shutters are provided
with approved quality of fixtures like handles made out of zamac alloy die cast and powder Sqm 5434.00
coated, receiver made out of glass filled nylone and hinges made out of CRCA powder
coated. 4mm thick glass should be fixed with EPDM gaskets. Guard bars fabricated out of
10mm square bright bars shall be fixed horizontally at 125mm C/C by rivetting to the
external frame. The above frames are fixed to the concrete / masonry walls by means of self
expanding screws.”
with 4mm float glass with gaurd bars

7.24.1.d "Providing and fixing cold rolled prepainted steel windows of IS standards, made out of
0.6mm thick deep drawing quality galvanised on both sides 120gms/sq.mtr. Primer coat upto
5 microns with thermosetting epoxy resin and finish painted with a polyester based paint 20
microns thick. The size of profiles is approximately 46 x 52mm for external frames,
46x46mm section for shutters, 46x70mm section for centre mullion/transom and 18x31mm
section is for fixing glasses. The section should be cut to length joint mitred and assembling
by means of corner brackets made out of cold rolled cold annealed strips of 1.2mm thick
duly galvanised and fixed with nickle plated self taping screws.The shutters are provided
with approved quality of fixtures like handles made out of zamac alloy die cast and powder Sqm 5618.00
coated, receiver made out of glass filled nylone and hinges made out of CRCA powder
coated. 4mm thick glass should be fixed with EPDM gaskets. Guard bars fabricated out of
10mm square bright bars shall be fixed horizontally at 125mm C/C by rivetting to the
external frame. The above frames are fixed to the concrete / masonry walls by means of self
expanding screws.”
with 4mm tinted glass with gaurd bars

7.25 Providing and fixing cold rolled prepainted steel partitions of IS standards, made out of
0.6mm of deep drawing quality galvanised on both sides 120gms/Sq.mtr. Primer coated upto
5 microns with thermosetting epoxy resin and finish painted with a polyester based paint 20
microns thick. The size of profiles is 46X52mm for external frame, section for mullion or
transom is of size 46x70mm and section for fixing glass/board is of 18x31mm. The section
should be cut to length joint mitred and assembling by means of corner brackets made out of
cold rolled cold annealed strips of 1.2mm thick duly galvanised and fixed with nickel plated Sqm 2700.00
self taping screws. 5mm thick glass should be fixed with EPDM gaskets. 10mm thick
prelaminated particle board shall be fixed with the help of the clipping bead. The above
frames are fixed to the concrete / masonry walls and floors by means of self expanding
screws.

Page No. 39

Page 29 of 350
7.26 Supplying and fixing pressed steel door frames size 125x65 mm manufactured from 1.25mm
thick carbon steel or imported steel strips with mitred joints of 900 for door openings and
shutters made out of seasoned Honne wood, styles of 30 mm, thick with lock rail of 160 mm,
width, top and side rails of 100 mm. width and bottom rails of 250 mm width and panel
filling with 12mm thick particle board of exterior grade bonded with phenol formal dehide
resin and the shutter shall be rot proof, vermin proof, heat resistant guaranteed against
shrinkage, warpage and such other defects for a period of 3 years. This shall be as per Sqm 3500.00
approved drawings, specification and direction including cost of conveyance, manufacturing,
painting with enamel paint 2 coats over primer coat, cost of labour for all items of work,
machinery, equipment and all other incidental charges with all lead, lift, loading and
unloading etc., complete. The Hollow portion of the frame to be filled with cement concrete
1:2:4.

7.27 "Supplying and fixing pressed steel window frame of size 100 x 50mm manufactured from
1.25 mm thick carbon steel or imported steel strips with neat mitred joints at 900degree for
window openings and shall be suitable to fix M.S. grills as per design and drawings using
12mm dia rods at 100mm Centre to Centre horizontally and two members of M.S flats of
6mmx40mm size at 150mm apart, welded into a frame of 6mmx40mm size M.S. flats with
16mm size lugs, and 8 Nos. of 100mm size hinges, 4 Nos of Butt Stay pins and 4 Nos.
Tower bolts and shutters half panelled and hallf glazed with shutters made out of seasoned
honne wood, styles of 30mm thick and 100mm width and rails of 30mm thick and 100mm Sqm 3800.00
width and using 4mm thick pin headed glass and panel, filling with 12mm thick particle
board of exterior grade bonded with phenol formal dehide resin and the shutter shall be rot
proof vermin proof, heat resistant guaranteed against shrinkage, warp age and such other
defects for a period of 3 years.This shall be as per approved drawing, specification and
direction including cost of conveyance, manufacturing painting with 2 coats enamel paint
over one coat of primer, cost of labour for all items of work, machinery, equipment and all
other incidental charges with all lead, lift loading and unloading etc., complete. The Hollow
portion of the frame to be filled with cement concrete 1:2:4.”
7.28 Providing electric welding using carbon electrodes including cost of welding machine,
power charges, welding rods, and labour charges for welding etc., complete as per cm 2.50
specification.
7.29 Fabricating, supplying and erecting M.S. TubularTruss of span upto 10m. The bottom and
top member is provided with 50x50x6mm double equal angles, welded back to back and in
between top and bottom line, in areas of mid section is provided with 50x50x6mm equal
single angle for vertical and inclined members and at supporting ends 40x40x5mm single
angle is provided. All the members are welded together with 6mm gusset plate as per
Drawing. The entire truss is anchored in RCC column by using 4 Nos. of M.S. anchor bolts
at each support, with 10mm thick base plate and shoe plate.The work includes cutting,
straightening, placing in position of M.S angle and wleding wherever necessary, and Kgs 110.00
applying one coat of red oxide primer coat to all themembers including cost of all materials,
labour charges, and hire charges of machineries for cutting, welding, grinding and erection
equipments, with all lead and lift, transportation, etc., complete as per specification. (Page
No. 40 Item No. 7.29 of CSR 2015-16).

Page No. 40
7.30 Fabricating, supplying & erecting M.S. angular Truss of span upto 10m. The bottom & top
member is provided with 50x50x6mm double equal angles, welded back to back and in
between top & bottom line, in areas of mid section is provided with 50x50x6mm equal
single angle for vertical and inclined members and at supporting ends 40x40x5mm single
angle is provided. All the members are welded together with 6mm gusset plate as per
Drawing No.CBS/ SD/K-Mantap/9/MND/97. The entire truss is anchored in RCC column
by using 4 Nos. of M.S. anchor bolts at each support, with 10mm thick base plate and shoe
plate.The work includes cutting, straightening, placing in position of M.S angle and wleding Kgs 117.00
wherever necessary, and applying one coat of red oxide primer coat to all the members
including cost of all materials, labour charges, & hire charges of machineries for cutting,
welding, grinding & erection equipments, etc., complete as per specification. (Page No. 40
Item No. 7.30 of CSR 2015-16).

Page 30 of 350
7.31 Fabricating, providing and erecting in poiston of M S Ornamental security Grill Gate
without hot dip using 75 x 12mm M S Flat for alround frame work with verticals at the
centre and horizontal centere support M S Square of 20 x20 mm of different heights as
shown in the drawing are to be fixed at 16 cms C/C for suqare bars of full height and at 8cms
C / C for bottom rods providg ornamental C I Designers at the botom and C I arrows inthe
midle and top. The entire frame work is to be fixed by means of expansion bolts to the brick
pillars with necesary drillling holes. the work includes providng two coats of enamel Kgs 126.00
painting over one coatr of red lead ready mix primer coat etc complete cost of all labour,
painting, erection charges using hoist pulleycranes with all lead and lift, loading,
transporting and unloading using hoist pulley cranes, scaffolding charges and all other
incidental charges required for successful completion fo the work as per specification and
drawings

7.32 Fabricating, providing and erecting in poiston of Hot dip galvanised M.S.Ornamental
security Grill Gate using 75 x 12mm M S Flat for alround frame work with verticals at the
centre and horizontal centere support M S Square of 20 x20 mm of different heights as
shown in the drawing are to be fixed at 16 cms C/C for suqare bars of full height and at 8cms
C / C for bottom rods providg ornamental C I Designers at the botom and C I arrows inthe
midle and top. The entire frame work is to be fixed by means of expansion bolts to the brick Kgs 145.00
pillars with necesary drillling holes. the work includes providng two coats of enamel
painting over one coat of red lead ready mix primer coat etc complete cost of all labour,
painting, erection charges using hoist pulleycranes etc as per specification and drawings.

7.33 Fabricating, providing and erecting in poiston of M S Ornamental security Grill without hot
dip using 75 x 12mm M S Flat for alround frame work with verticals at the centre and
horizontal centere support M S Square of 20 x20 mm of different heights as shown in the
drawing are to be fixed at 16 cms C/C for suqare bars of full height and at 8cms C / C for
bottom rods providg ornamental C I Designers at thebotom and C I arrows inthe midle and
top. The entire frame work is to be fixed by means of expansion bolts to the brick pillars Kgs 131.00
with necesary drillling holes. the work includes providng two coats of enamel painting over
one coatr of red lead ready mix primer coat etc complete cost of all labour, painting, erection
charges using hoist pulleycranes etc as per specification and drawings.

Page No. 41
7.34 Fabricating, providing and erecting in poiston of Hot dip galvanised M S Ornamental
security Grill using 75 x 12mm M S Flat for alround frame work with verticals at the centre
and horizontal centere support M S Square of 20 x20 mm of different heights as shown in
the drawing are to be fixed at 16 cms C/C for suqare bars of full height and at 8cms C / C for
bottom rods providg ornamental C I Designers at the botom and C I arrows inthe midle and
top. The entire frame work is to be fixed by means of expansion bolts to the brick pillars
with necesary drillling holes. the work includes providng two coats of enamel painting over Kgs 159.00
one coatr of red lead ready mix primer coat etc complete cost of all labour, painting, erection
charges using hoist pulleycranes with all lead and lift, loading, transporting and unloading
using hoist pulley cranes, scaffolding charges and all other incidental charges required for
successful completion fo the work as per specification and drawings,

7.35 Providing and fixing M.S. Hand railing for Balcony with 50mm dia. M.S. hollow pipe of 14
gauge, welded to 20mmx20mm M.S. square rod placed vertically, spaced at 100mm at
regular intervals of 600mm. These vertical rods laterally tied to 3 horizontal rods spaced at
equal interval. These assembly is fixed to concrete by using expansion bolts and welding the
same to reinforcement bars and making good the surface. All the joints and sections hould be
Sqm 2646.00
cut to length, welded and grinded wherever necessary etc., complete . The work includes
cost of all materials, labour charges for all items of work, hire charges for welding, cutting
and grinding equipment, and electricity charges, etc., complete as per specification and
drawing.

Page 31 of 350
7.36 Providing and fixing M.S.Grill over existing compound wall as per Chief Architect drawing
No. 12686, using 16mm x 16mm M.S.Square rod at 150mm c/c spacing and 6mm x 40mm
M.S. flats at horizontal and 6mm x12mm M.S. flat for ornamental design and providing
shop edge design at the vertex of every vertical rods, including welding, grinding wherever
necessary. All the steel surface should be thoroughly cleaned free of rust and painted with
Sqm 5224.00
anti corrosive paint (shop paint) etc., complete. The work includes cost of all materials,
labour charges for all items of work, hire charges for welding, cutting and grinding
equipment, and electricity charges, etc., complete as per specification.

7.37 Providing and fixing M.S. Gate as per Chief Architect Drawing, using 50mm x 50mm 14
guage M.S. hollow pipe frame work bent to ornamental shape as shown in the drawing and
35mm x 6mm and 16 x 16mm Square rods for verticals alternatively spaced at 4cms c/c in
two halves and 40mmx6mm M.S. flats for horizontal member and at the top cast iron spikes
are provided at alternate vertical members asshown in the drawing etc., complete. All the
steel surface should be thoroughly cleaned free of rust and painted with anti corrosive paint
(shop paint) etc., complete. The work includes cost of all materials, labour charges for all Sqm 2934.00
items of work, hire charges for welding, cutting and grinding equipment, and electricity
charges, with lead and lift, loading and unloading charges, etc., complete as per
specifiocation. (P. No. 43 / I. No. 7.37 of CSR 2015-16)

Page No. 42
7.38 Providing and fixing Stainless steel staircase raling as per Chief Architect Drawing No.
11520/ HRSC with hand rail 50mm dia 16 guage hollow pipe welded to vertical hollow
50mm dia pipe of 16 guage, stainless steel vertical pipe spaced at 1.20m regular intervals,
and 5 Nos of 25mm dia. Stainless steel hollow horizontal pipe are welded to vertical 50mm
dia hollow pipe. The entire assembly is fixed to staircase concrete by using expansion bolts Sqm 6147.00
by drilling concrete etc., complete including cost of materials, labour, HOM of machineries
and electrical charges, etc., complete as per specifications. (P. No. 43 / I. No. 7.38 of CSR
2015-16)

7.39 Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or
Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60
mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates
10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed
horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with
elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal
intervals including cutting, welding, bending wherever necessary with suitable caps @ tops,
bottoms & corners finishing with mat / shining etc., complete including cost and conveyance Sqm 5821.00
of all materials, labour for all items of work, HOM of equipment with all lead and lift,
loading and unloading, transportation charges and all other incidental charges etc., complete
as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase
for physically challenged. (P. No. 43 / I. No. 7.39 of CSR 2015-16)

Page No. 43

8.0 8.ROOFING

8.1 KSRB 8.1 : Providing and fixing in position stone slab roofing 10 to 12 cms thick laid to
line and level over wooden rafters or R.C.C. battens, pointing exposed joints with cement
mortar 1:4 including cost of materials, labour, curing complete as per specifications. Sqm 990.00
( wooden rafters and R.C.C. battens to be paid seperately ) Specification No. KBS

8.2 KSRB 8.2 : Providing and fixing in position black cuddapah slab / Shahabad slab / Thandur
blue slab 4 cms thick for roofing laid to line and level over wooden rafters or R.C.C. battens
pointing exposed joints with cement mortar 1:4 including cost of materials, labour, curing Sqm 549.00
complete as per specifications. (wooden rafters and R.C.C. battens to be paid seperately )

Page 32 of 350
8.3 KSRB 8.3-1 : Providing and laying to required line and slope roofing with corrugated
asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts and nuts
8mm. dia C.I plain and bitumen washers over the existing purlins, rafters and trusses Sqm 362.00
including cost of materials, labour, complete as per specifications. Specification No. KBS
8.5 (P.No. 46, I.No. 8.3 of PWD SR 2015-16)
8.4 KSRB 8.5 : Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of
12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, cum 1902.00
including cost of materials, labour, curing complete as per specifications.
8.5 KSRB 8.6-1 : Providing and fixing on wall surface cast iron rain down water pipes 75mm
dia including filling the joints with spun yarn soaked in neat cement slurry 1:2 with
necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, m 1097.00
including cost of materials, labour, complete as per specifications.
8.6 KSRB 8.3-2 : Providing and laying to required line and slope roofing with semi-corrugated (
Trafford ) asbestos cement sheet 6mm. thick fixed with galvanised iron J or L hooks, bolts
and nuts 8mm. dia C.I plain and bitumen washers, over the existing purlins, rafters and Sqm 395.00
trusses including cost of materials, labour, complete as per specifications.

8.7 KSRB 8.3-3 Extra for A.C. sheet corrugated / semi-corrugated sheet roofing with vertical
Sqm 10.00
sheeting to a pitch exceeding 60 degrees
8.8 KSRB 8.3-4 : Providing and fixing ridges, hips with asbestos cement sheet roofing with G.I.
J or L hooks, bolts and nuts 8mm. dia G.I.plain and bitumen washers, serrated or plain
wings, adjustable ridges, including cost of materials, labour, complete as per specifications. m 325.00

8.9 KSRB 8.3-5 : Providing and fixing northlight adjustable ridges, hips with asbestos cement
sheet roofing with G.I. J or L hooks, bolts and nuts 8mm. dia G.I.plain and bitumen washers,
serrated or plain wings, adjustable ridges, including cost of materials, labour, complete as m 220.00
per specifications.
Page No. 46
8.10 KSRB 8.4-1 : Providing and fixing Mangalore tile roofing using first class tiles with
necessary special tiles for ridges and hips, teak wood reepers of size 50x25mm and pointed
with cement mortar 1:4 over the existing rafters including cost of materials, labour, curing Sqm 1201.00
complete as per specifications. Specification No. KBS 8.17. (P.No. 47, I.No. 8.10 of PWD
SR 2015-16)
8.11 KSRB 8.4-2 :Providing and fixing Mangalore tile roofing using first class tiles with
necessary special tiles for ridges and hips,nandi wood reepers of size 50x25mm and
pointed with cement mortar 1:4 over the existing rafters including cost of materials, labour, Sqm 766.00
curing complete as per specifications. Specification No. KBS 8.17
8.12 KSRB 8.4-3 : Providing and fixing Mangalore tile roofing using first class tiles with
necessary special tiles for ridges and hips,jungle wood reepers of size 50x25mm and
pointed with cement mortar 1:4 over the existing rafters including cost of materials, labour, Sqm 629.00
curing complete as per specifications. Specification No. KBS 8.17
8.14 KSRB 8.6-3 : Providing and fixing on wall surface asbestos cement rain down water pipes
75mm dia including filling the joints with spun yarn soaked in neat cement slurry 1:2 with
necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, m 409.00
including cost of materials, labour, curing complete as per specifications. Specification No.
KBS 8.27, 8.28
8.15 KSRB 8.6-4 : Providing and fixing on wall surface asbestos cement rain down water pipes
100 mm dia including filling the joints with spun yarn soaked in neat cement slurry 1:2 with
necessary specials like shoes, bends and offsets fixed with iron clamps, wall plugs, screws, m 448.00
including cost of materials, labour, curing complete as per specifications. Specification No.
KBS 8.27, 8.28
8.16 KSRB 8.6-5 : Providing and fixing on wall surface 2.5 kg / sq.cm H.D.P.E. rain down water
pipes 90 mm outer dia approved make and brand with necessary specials like shoes, bends
and offsets fixed with iron clamps, wall plugs, screws, including cost of materials, labour, m 398.00
curing complete as per specifications.
8.17 KSRB 8.6-6 : Providing and fixing on wall surface 2.5kg / sq.cm H.D.P.E. rain down water
pipes 110mm outer dia approved make and brand with necessary specials like shoes, bends
and offsets fixed with iron clamps, wall plugs, screws, including cost of materials, labour, m 478.00
curing complete as per specifications.

Page 33 of 350
8.18 KSRB 8.6-7 : Providing and fixing on wall surface 4.0 kg / sq.cm H.D.P.E. rain down water
pipes 90 mm outer dia. approved make and brand with necessary specials like shoes, bends
and offsets fixed with iron clamps, wall plugs, screws, including cost of materials, labour, m 428.00
complete as per specifications.
8.19 KSRB 8.6-8 : Providing and fixing on wall surface. 40 kg / sq.cm H.D.P.E. rain down water
pipes 110mm outer dia. approved make and brand with necessary specials like shoes, bends
and offsets fixed with iron clamps, wall plugs, screws, including cost of materials, labour, m 568.00
complete as per specifications. (P.No. 47/ I.No. 8.19 of CSR 2015-16)
8.20 KSRB 8.7-1 :Providing and fixing in position 10mm thick plaster of paris (Gypsum
anhydrous ) for ceiling flat surface upto a height of 5 m above floor level over aluminium
25mm / 6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to Sqm 1079.00
metal frames including cost of materials, labour, curing complete as per specifications.
(P.No. 47/ I.No. 8.20 of CSR 2015-16)
8.21 KSRB 8.7-2 : Providing and fixing in position 10mm thick plaster of paris (Gypsum
anhydrous ) for ceiling curved surface upto a height of 5 m above floor level over aluminium
strips 25mm / 6mm with 10mm gap in between and reinforced with rabbit wire mesh fixed Sqm 1173.00
to meatal frames including cost of materials, labour, curing complete as per specifications.

8.22 KSRB 8.7-3 : Extra over item No. 8.7-1 and 8.7-2 for any sunk or raised moulded design
Sqm 440.00
plaster of paris ( Gypsum anhydrous ) ceiling
8.23 KSRB 8.7-4 : Extra over item No. 8.7-1 and 8.7-2 for providing plaster of paris (Gypsum
Sqm/m 100.00
anhydrous ) ceiling above 5 m height from floor level

Page No. 47

8.24 KSRB 8.7-5 : Providing and fixing in position 12mm thick plaster of paris (Gypsum
anhydrous ) for ceiling flat surface with ceiling tiles upto a height of 5 m above floor level
over wooden frames and rendered smooth with plaster of paris (frame work to be measured Sqm 949.00
and paid for seperately ) including cost of materials, labour, curing complete as per
specifications.
8.25 KSRB 8.7-6 : Extra over item No. 8.7-5 for providing plaster of paris (Gypsum anhydrous )
Sqm/m 44.00
ceiling tiles above 5 m height from floor level
8.26 Providing top layer with 12mm thick silica latex plaster with smooth finishing on top
Sqm 360.00
surface. (P.No. 48, I.No. 8.26 of PWD SR 2015-16)
8.27 Providing and fixing 6mm Bronze Multi wall poly carbonate sheet for Tubular structure. The
work including cost of all materials, labour charges, and hire charges of machineries for
cutting, welding, grinding and erection equipments, complete as per specification. Sqm 2490.00

8.28 Providing and fixing 15 mm thick densified regular edged eco friendly light weight calcium
silicate False ceiling tiles of approved texture spintone/cosmos/Hexa or equivalent of size
595X595 mm in true horizontal level suspended on inter locking metal grid of hot dipped
galvanized steel sections (galvanizing @ 120 grams per sqm including both sides) consisting
of main T runner suitably spaced at joints to get required length and of size 24 X 38 mm
made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross T
of size 24 X 28 mm made out of 0.33 mm (minimum) sheet, 1200 mm long spaced between
main T at 600 mm centre to centre to form a grid of 1200 X 600 mm and secondary cross T Sqm 2000.00
of length 600 mm and size 24 X 28 mm made of 0.33 mm thick (minimum) sheet to be inter
locked at middle of the 1200X600 mm panel to form grid of size 600X600 mm resting on
periphery walls / partitions on a Perimeter wall angle precioated steel of size 24X24X3000
mm made of 0.40 mm thick with 25 mm long dry wall screwes at 230 mm intervals and
laying 15 mm thick densifed edges calcium silicate ceiling tiles of approved texture
(Spintone / Cosmos) in the grid including cutting / making opening for services like
diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required, Main T
runners ti be suspended from ceiling using G I slotted cleats of size 25X35X1.6 mm fuixed
8.29 Providing and fixing of pre pigmented extruded orange cement roof tiles of size 420mm x
330mm with necessary specials such as Ridges, Barges and Nails etc. including cast of
providing PVC (6.00kgs/sq cm) gutters of min 6” radius and down water pipes of 4” dia as
per the roof design on EXISTING MS/WOODEN ROOF or TRUSS. Including cost of Sqm 713.00
materials, scaffoldings, labour etc., compelte as per specifications.

Page 34 of 350
Page No. 48

8.30 Providing and fixing of pre pigmented extruded orange cement roof tiles of size 420mm x
330mm with necessary specials such as Ridges, Barges and Nails etc., including cost of
providing PVC (6.00kgs/ sqcm) gutters of min 6” radius and down water pipes of 4” dia as Sqm 681.00
per roof design on EXISTING CONCRETE SLOPING ROOF SLAB. Including cost of
mortar band, all materials labour as per specifications.
8.31.1 Providing and laying non - asbestos high impact ploypropylene reinforced corrugated
cement roofing sheet reinforced with natural Grey colour and with a blend of strong
factory made fibre as per IS:14871 and IS:9933:1995 (E) roofing upto any pitch and fixing
with polymer coated J or L hooks, bolts and nuts 8mm dia, G I plain and bitumen washers or
with self drilling fastener and EPDM washers ete. complete but excluding the cost of purlins, Sqm 534.00
refters and trusses. including cutting to size and shape of corrugated sheets wherever
required. and cost of materials, labour, complete as per specifications.

8.31.1 Providing and laying non - asbestos high impact ploypropylene reinforced corrugated
cement roofing sheet reinforced with Other colours and with a blend of strong factory made
fibre as per IS:14871 and IS:9933:1995 (E) roofing upto any pitch and fixing with polymer
coated J or L hooks, bolts and nuts 8mm dia, G I plain and bitumen washers or with self
drilling fastener and EPDM washers ete. complete but excluding the cost of purlins, refters Sqm 582.00
and trusses. including cutting to size and shape of corrugated sheets wherever required. and
cost of materials, labour, complete as per specifications.

Page No. 49

9.0 9.WOOD WORK

9.1 KSRB 9-1 :Labour for providing Teak wood wrought and putup for purlins, common rafters
and similar work including cost of labour, HOM of machineries complete as per cum 3532.00
specifications. Specification No. KBS 9.4
9.2 KSRB 9-2.1 :Providing Honne wood wrought and putup for purlins, common rafters and
similar work including cost of materials, labour, HOM of machineries complete as per cum 96884.00
specifications. Specification No. KBS 9.27
9.3 KSRB 9-2.2 :Providing Mathi / Nandi wood wrought and putup for purlins, common rafters
and similar work including cost of materials, labour, HOM of machineries complete as per cum 80013.00
specifications. Specification No. KBS 9.27
9.4 KSRB 9-2.3 :Providing Sal wood wrought and putup for purlins, common rafters and similar
work including cost of materials, labour, HOM of machineries complete as per cum 63141.00
specifications. Specification No. KBS 9.27
9.5 KSRB 9-2.4 :Providing Jungle wood such as Nerale, Neem wrought and putup for purlins,
common rafters and similar work including cost of materials, labour, HOM of machineries cum 47568.00
complete as per specifications. Specification No. KBS 9.27
9.10 KSRB 9.4-1 : Providing Teak wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including making plaster groves
( excluding cost of cement concrete and side clamps ), but including cost of materials,
labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33. cum 185914.00
(P.No.51, I.No. 9.10 of PWD SR 2015-16)

9.11 KSRB 9.4-2 : Providing Honne wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including making plaster groves
( excluding cost of cement concrete and side clamps ), but including cost of materials, cum 102855.00
labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33

Page 35 of 350
9.12 KSRB 9.4-3 : Providing Mathi / Nandi wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including making plaster groves
( excluding cost of cement concrete and side clamps ), but including cost of materials, cum 80792.00
labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33

9.13 KSRB 9.4-4 : Providing WHITE Sal wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including making plaster groves
( excluding cost of cement concrete and side clamps ), but including cost of materials, cum 63921.00
labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33. (P.
No. 51/ I. No. 9.13 of CSR 2015-16)
9.13.1 KSRB 9.4-4 : Providing RED Sal wood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including making plaster groves
( excluding cost of cement concrete and side clamps ), but including cost of materials, cum 58730.00
labour, HOM of machineries complete as per specifications. Specification No. KBS 9.33

9.14 KSRB 9.5-1 : Providing and fixing in position fully panelled Teak wood shutters for doors,
styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 8300.00
HOM of machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34
9.15 KSRB 9.5-2 : Providing and fixing in position fully panelled Honne wood shutters for doors,
styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 4643.00
HOM of machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34
9.16 KSRB 9.5-3 : Providing and fixing in position fully panelled Mathi/Nandi wood shutters for
doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and
styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, Sqm 3925.00
labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34
9.17 KSRB 9-6.1 : Providing and fixing in position fully panelled Teak wood shutters for doors,
styles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 7814.00
HOM of machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34
9.18 KSRB 9-6.2 : Providing and fixing in position fully panelled Honne wood shutters for doors,
styles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 4392.00
HOM of machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34
9.19 KSRB 9-6.3 : Providing and fixing in position fully panelled Mathi/ Nandi wood shutters for
doors, styles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and
styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, Sqm 3719.00
labour, HOM of machineries complete as per specifications. ( excluding cost of fixtures)
Specification No. KBS 9.34
9.20 KSRB 9-7.1 : Providing and fixing in position fully panelled Teak wood shutters for doors,
styles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 7327.00
HOM of machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

Page No. 51

9.21 KSRB 9-7.2 : Providing and fixing in position fully panelled Honne wood shutters for doors,
styles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 4141.00
HOM of machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34

Page 36 of 350
9.22 KSRB 9-7.3 :Providing and fixing in position fully panelled Mathi/ Nandi wood shutters for
doors, styles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and
styles 100mm wide as per drawing and panels of 25mm thick including cost of materials, Sqm 3513.00
labour, HOM of machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34
9.23 KSRB 9-8.1 : Providing and fixing in position fully panelled Teak wood shutters for doors,
styles and rails of 25mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 6771.00
HOM of machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34
9.24 KSRB 9-8.2 : Providing and fixing in position fully panelled Honne wood shutters for doors,
styles and rails of 25mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, Sqm 3876.00
HOM of machineries complete as per specifications. (excluding cost of fixtures)
Specification No. KBS 9.34
9.25 KSRB 9-8.3 : Providing and fixing in position fully panelled Mathi/ Nandi wood shutters
for doors, styles and rails of 25mm. thick with bottom and lock rails 180mm wide top rail
and styles 100mm wide as per drawing and panels of 25mm thick including cost of Sqm 2641.00
materials, labour, HOM of machineries complete as per specifications. (excluding cost of
fixtures) Specification No. KBS 9.34
9.26 KSRB 9-9.1: Providing and fixing in position Teak wood half panelled and half glazed
shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 25mm thick, 4mm thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 6970.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.27 KSRB 9-9.2: Providing and fixing in position Honne wood half panelled and half glazed
shutters for doors, styles and rails of 40mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 25mm thick, 4mm thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 4092.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.28 KSRB 9-10.1 : Providing and fixing in position Teak wood half panelled and half glazed
shutters for doors, styles and rails of 35mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 25mm thick, 4mm thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 6483.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures )

9.29 KSRB 9-10.2 :Providing and fixing in position Honne wood half panelled and half glazed
shutters for doors, styles and rails of 35mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 25mm thick, 4mm thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 3841.00
including cost of materials, labour, HOM of machineries complete as per specifications.
(excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.30 KSRB 9-11.1 : Providing and fixing in position Teak wood half panelled and half glazed
shutters for doors, styles and rails of 30mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 25mm thick, 4mm thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 5899.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.31 KSRB 9-11.2 : Providing and fixing in position Honne wood half panelled and half glazed
shutters for doors, styles and rails of 30mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 25mm thick, 4mm thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 3540.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

Page 37 of 350
9.32 KSRB 9-12.1 : Providing and fixing in position Teak wood half panelled and half glazed
shutters for doors, styles and rails of 30mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 20mm thick, 4mm. thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 5566.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42
Page No. 52
9.33 KSRB 9-12.2 : Providing and fixing in position Honne wood half panelled and half glazed
shutters for doors, styles and rails of 30mm. thick with bottom and lock rails 180mm wide
top rail and styles 100mm wide as per drawing and panels of 20mm thick, 4mm. thick plain
glass, fixed with beading 15mm wide and thickness to finish with the shutters surface Sqm 3381.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.42

9.34 KSRB 9-13-1: Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade Melamine
impregnated prelamination particle board of approved colour on both sides including cost of Sqm 3601.00
materials, labour, HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4

9.35 KSRB 9-13-2 : roviding and fixing in position shutters for doors made out of Honne wood
styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade Melamine
impregnated prelamination particle board of approved colour on both sides including cost of Sqm 3578.00
materials, labour, HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4 on one side

9.36 KSRB 9-13-3 : Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade plain particle board Sqm 3418.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.26.3
9.37 KSRB 9-14-1: Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade Melamine
impregnated prelamination particle board of approved colour on both sides including cost of Sqm 3302.00
materials, labour, HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4

9.38 KSRB 9-14-2 : Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade Melamine
impregnated prelamination particle board of approved colour on one side including cost of Sqm 3358.00
materials, labour, HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.4 one side

9.39 KSRB 9-14-3 : Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade plain particle board Sqm 3357.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.26.3
9.40 KSRB 9-15-1: Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade Melamine
impregnated prelamination particle board of approved colour on both sides including cost of Sqm 3116.00
materials, labour, HOM of machineries complete as per specifications. (excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.3
Page No. 53

Page 38 of 350
9.41 KSRB 9-15-2 : Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade Melamine
impregnated prelamination particle board of approved colour on one side including cost of Sqm 3093.00
materials, labour, HOM of machineries complete as per specifications. (excluding cost of
fixtures ) Specification No. KBS 9.34, 9.26.3 one side

9.42 KSRB 9-15-3 : Providing and fixing in position shutters for doors made out of Honne wood
styles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and styles
100mm wide as per drawing and panels of 18mm thick of exterior grade Plain particle board Sqm 2933.00
including cost of materials, labour, HOM of machineries complete as per specifications.
( excluding cost of fixtures ) Specification No. KBS 9.34, 9.26.3
9.43 KSRB 9-16.1 : Providing and fixing in position Teak wood fully panelled shutters for
windows with styles and rails of 35mm. thick, 75mm wide in two halves with panels of
25mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 9431.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34
9.44 KSRB 9-16.2 : Providing and fixing in position Honne wood fully panelled shutters for
windows with styles and rails of 35mm. thick, 75mm wide in two halves with panels of
25mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 4888.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34
9.45 KSRB 9-16.3 : Providing and fixing in position Mathi/ Nandi wood fully panelled shutters
for windows with styles and rails of 35mm. thick, 75mm wide in two halves with panels of
25mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 4122.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34

9.46 KSRB 9-16.4 : Providing and fixing in position fully panelled shutters for windows with
Honne wood styles and rails of 35mm. thick, 75mm wide in two halves with panels provided
with NUWUD ( MDF ) of 25mm thick including cost of materials, labour charges, HOM of Sqm 3647.00
machineries complete as per specifications. (excluding cost of fixtures ) Specification No.
KBS 9.34, 9.26.3
9.47 KSRB 9-17.1 : Providing and fixing in position Teak wood fully panelled shutters for
windows with styles and rails of 30mm. thick, 75mm wide in two halves with panels of
20mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 8026.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34
9.48 KSRB 9-17.2 : Providing and fixing in position Honne wood fully panelled shutters for
windows with styles and rails of 30mm. thick, 75mm wide in two halves with panels of
20mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 4237.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34
9.49 KSRB 9-17.3 : Providing and fixing in positionMathi/ Nandi wood fully panelled shutters
for windows with styles and rails of 30mm. thick, 75mm wide in two halves with panels of
20mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 3601.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34

9.50 KSRB 9-17.4 : Providing and fixing in position fully panelled shutters for windows with
Honne wood styles and rails of 30mm. thick, 75mm wide in two halves with panels provided
with NUWUD ( MDF ) of 18mm thick including cost of materials, labour charges, HOM of Sqm 3330.00
machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.26.3
9.51 KSRB 9-18.1 : Providing and fixing in position Teak wood fully panelled shutters for
windows with styles and rails of 25mm. thick, 75mm wide in two halves with panels of
20mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 7323.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34
Page No. 54
9.52 KSRB 9-18.2 : Providing and fixing in position Honne wood fully panelled shutters for
windows with styles and rails of 25mm. thick, 75mm wide in two halves with panels of
20mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 3920.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34

Page 39 of 350
9.53 KSRB 9-18.3 : Providing and fixing in position Mathi/ Nandi wood fully panelled shutters
for windows with styles and rails of 25mm. thick, 75mm wide in two halves with panels of
20mm thick including cost of materials, labour charges, HOM of machineries complete as Sqm 3341.00
per specifications. (excluding cost of fixtures ) Specification No. KBS 9.34

9.54 KSRB 9-18.4 : Providing and fixing in position fully panelled shutters for windows with
Honne wood styles and rails of 25mm. thick, 75mm wide in two halves with panels provided
with NUWUD ( MDF ) of 18mm thick including cost of materials, labour charges, HOM of Sqm 2906.00
machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.26.3
9.55 KSRB 9-18.5 : Providing and fixing in position fully panelled shutters for windows with
Honne wood styles and rails of 25mm. thick, 75mm wide in two halves with panels provided
with NUWUD ( MDF ) of 12mm thick including cost of materials, labour charges, HOM of Sqm 2845.00
machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.26.3
9.56 KSRB 9-19.1 : Providing and fixing in position Teak wood half panelled shutters at bottom
and half glazed at top for window shutters with styles and rails of 35mm. thick, 75mm wide
in two halves with panels of 25mm thick, 3mm thick reeded glass for top panels fixed with
wooden beading including cost of materials, labour charges, HOM of machineries complete
as per specifications. ( excluding cost of fixtures) Specification No. Providing and fixing in
position Teak wood half panelled shutters at bottom and half glazed at top for window
shutters with styles and rails of 35mm. thick, 75mm wide in two halves with panels of Sqm 8048.00
25mm thick, 3mm thick reeded glass for top panels fixed with wooden beading including
cost of materials, labour charges, HOM of machineries complete as per specifications.
( excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.57 KSRB 9-19.2 :Providing and fixing in position Honne wood half panelled shutters at bottom
and half glazed at top for window shutters with styles and rails of 35mm. thick, 75mm wide
in two halves with panels of 25mm thick, 3mm thick reeded glass for top panels fixed with
wooden beading including cost of materials, labour charges, HOM of machineries complete
as per specifications. ( excluding cost of fixtures) Specification No. Providing and fixing in
position Teak wood half panelled shutters at bottom and half glazed at top for window
shutters with styles and rails of 35mm. thick, 75mm wide in two halves with panels of Sqm 4425.00
25mm thick, 3mm thick reeded glass for top panels fixed with wooden beading including
cost of materials, labour charges, HOM of machineries complete as per specifications.
( excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.58 KSRB 9-19.3 :Providing and fixing in position Mathi/ Nandi wood half panelled shutters at
bottom and half glazed at top for window shutters with styles and rails of 35mm. thick,
75mm wide in two halves with panels of 25mm thick, 3mm thick reeded glass for top panels
fixed with wooden beading including cost of materials, labour charges, HOM of machineries
complete as per specifications. ( excluding cost of fixtures) Specification No. Providing and
fixing in position Teak wood half panelled shutters at bottom and half glazed at top for
window shutters with styles and rails of 35mm. thick, 75mm wide in two halves with panels Sqm 3844.00
of 25mm thick, 3mm thick reeded glass for top panels fixed with wooden beading including
cost of materials, labour charges, HOM of machineries complete as per specifications.
( excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.59 KSRB 9-19.4 :Providing and fixing in position windows half paneled shutters at bottom and
half glazed at top for window shutters with Honne wood styles and rails of 35mm. thick,
75mm wide in two halves with panels filled with NUWUD ( MDF ) of 18mm thick, 3mm
thick reeded glass for top panels fixed with wooden beading including cost of materials, Sqm 3699.00
labour charges, HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.42, 9.26.3

Page 40 of 350
9.60 KSRB 9-20.1 : Providing and fixing in position Teak wood half panelled shutters at bottom
and half glazed at top for window shutters with styles and rails of 30mm. thick, 75mm wide
in two halves with panels of 20mm thick, 3mm thick reeded glass for top panels fixed with
wooden beading including cost of materials, labour charges, HOM of machineries complete Sqm 7170.00
as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.61 KSRB 9-20.2 : Providing and fixing in position Honne wood half panelled shutters at
bottom and half glazed at top for window shutters with styles and rails of 30mm. thick,
75mm wide in two halves with panels of 20mm thick, 3mm thick reeded glass for top panels
fixed with wooden beading including cost of materials, labour charges, HOM of machineries Sqm 4024.00
complete as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.62 KSRB 9-20.3 : Providing and fixing in position Mathi/ Nandi wood half panelled shutters at
bottom and half glazed at top for window shutters with styles and rails of 30mm. thick,
75mm wide in two halves with panels of 20mm thick, 3mm thick reeded glass for top panels
fixed with wooden beading including cost of materials, labour charges, HOM of machineries Sqm 3519.00
complete as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.63 KSRB 9-20.4 : Providing and fixing in position windows half paneled shutters at bottom and
half glazed at top for window shutters with Honne wood styles and rails of 30mm. thick,
75mm wide in two halves with panels filled with NUWUD (MDF ) of 18mm thick, 3mm
thick reeded glass for top panels fixed with woodenbeading including cost of materials, Sqm 3191.00
labour charges, HOM of machineries completeas per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34,9.42, 9.26.3
Page No. 55
9.64 KSRB 9-21.1 : Providing and fixing in position half panelled shutters at bottomand half
glazed at top for window shutters with Teak wood styles and rails of25mm. thick, 75mm
wide in two halves with panels of 20mm thick, 3mm thick reeded glass for top panels fixed
with wooden beading including cost of materials, labour charges, HOM of machineries Sqm 6573.00
complete as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.65 KSRB 9-21.2 : Providing and fixing in position half panelled shutters at bottomand half
glazed at top for window shutters with Honne wood styles and rails of25mm. thick, 75mm
wide in two halves with panels of 20mm thick, 3mm thick reeded glass for top panels fixed
with wooden beading including cost of materials, labour charges, HOM of machineries Sqm 3778.00
complete as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.66 KSRB 9-21.3 : Providing and fixing in position half panelled shutters at bottomand half
glazed at top for window shutters with Mathi/ Nandi wood styles and rails of25mm. thick,
75mm wide in two halves with panels of 20mm thick, 3mm thick reeded glass for top panels
fixed with wooden beading including cost of materials, labour charges, HOM of machineries Sqm 3358.00
complete as per specifications. (excluding cost of fixtures) Specification No. KBS 9.34, 9.42

9.67 KSRB 9-21.4 : Providing and fixing in position windows half paneled shutters at bottom and
half glazed at top for window shutters with Honne wood styles and rails of 25mm. thick,
75mm wide in two halves with panels filled with NUWUD ( MDF ) of 18mm thick, 3mm
thick reeded glass for top panels fixed with wooden beading including cost of materials, Sqm 2944.00
labour charges, HOM of machineries complete as per specifications. ( excluding cost of
fixtures ) Specification No. KBS 9.34, 9.42, 9.26.3

9.68 KSRB 9-22.1 : Providing and fixing in position fully glazed for windows shutters with Teak
wood styles and rails of 35mm. thick 75mm wide in single shutters with 4mm thick plain
glass fixed with wooden beading including cost of materials, labour charges, HOM of Sqm 5669.00
machineries complete as per specifications. (excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42
9.69 KSRB 9-22.2 : Providing and fixing in position fully glazed for windows shutters with
Honne wood styles and rails of 35mm. thick 75mm wide in single shutters with 4mm thick
plain glass fixed with wooden beading including cost of materials, labour charges, HOM of Sqm 3275.00
machineries complete as per specifications. (excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42

Page 41 of 350
9.70 KSRB 9-23.1 : Providing and fixing in position fully glazed for windows shutters with Teak
wood styles and rails of 30mm. thick, 75mm wide in single shutters with 4mm thick plain
glass fixed with wooden beading including cost of materials, labour charges, HOM of Sqm 5142.00
machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42
9.71 KSRB 9-23.2 :Providing and fixing in position fully glazed for windows shutters with
Honne wood styles and rails of 30mm. thick, 75mm wide in single shutters with 4mm thick
plain glass fixed with wooden beading including cost of materials, labour charges, HOM of Sqm 3038.00
machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42
9.72 KSRB 9-24.1 : Providing and fixing in position fully glazed for windows shutters with Teak
wood styles and rails of 25mm. thick, 75mm wide in single shutters with 4mm thick plain
glass fixed with wooden beading including cost of materials,labour charges, HOM of Sqm 4615.00
machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42
9.73 KSRB 9-24.2 : Providing and fixing in position fully glazed for windows shutters with
Honne wood styles and rails of 25mm. thick, 75mm wide in single shutters with 4mm thick
plain glass fixed with wooden beading including cost of materials,labour charges, HOM of Sqm 2800.00
machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42
Page No. 56
9.74 KSRB 9-25.1 :Providing and fixing in position fully glazed shutters for ventilators side hung
or central pivoted with Teak wood styles and rails of 30mm. thick, 50mm wide and central
divider of 30mm. wide, 3mm thick reeded glass fixed with wooden beading of size 10mm
wide flushed to the thickness of the frame including cost of materials, labour charges, HOM Sqm 6857.00
of machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42

9.75 KSRB 9-25.2 :Providing and fixing in position fully glazed shutters for ventilators side hung
or central pivoted with Honne wood styles and rails of 30mm. thick, 50mm wide and central
divider of 30mm. wide, 3mm thick reeded glass fixed with wooden beading of size 10mm
wide flushed to the thickness of the frame including cost of materials, labour charges, HOM Sqm 3902.00
of machineries complete as per specifications. ( excluding cost of fixtures ) Specification No.
KBS 9.34, 9.42

9.76 KSRB 9-25.3 : Providing and fixing in position fully glazed shutters for ventilators side
hung or central pivoted with Mathi/ Nandi wood styles and rails of 30mm. thick, 50mm
wide and central divider of 30mm. wide, 3mm thick reeded glass fixed with wooden beading
of size 10mm wide flushed to the thickness of the frame including cost of materials, labour Sqm 3450.00
charges, HOM of machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

9.77 KSRB 9-26.1 : Providing and fixing in position fully glazed shutters for ventilators side
hung or central pivoted with Teak wood styles and rails of 25mm. thick, 50mm wide and
central divider of 25mm. wide, 3mm thick reeded glass fixed with wooden beading of size
10mm wide flushed to the thickness of the frame including cost of materials, labour charges, Sqm 4001.00
HOM of machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

9.78 KSRB 9-26.2 : Providing and fixing in position fully glazed shutters for ventilators side
hung or central pivoted with Honne wood styles and rails of 25mm. thick, 50mm wide and
central divider of 25mm. wide, 3mm thick reeded glass fixed with wooden beading of size
10mm wide flushed to the thickness of the frame including cost of materials, labour charges, Sqm 2390.00
HOM of machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

9.79 KSRB 9-26.3 : Providing and fixing in position fully glazed shutters for ventilators side
hung or central pivoted with Mathi/ Nandi wood styles and rails of 25mm. thick, 50mm
wide and central divider of 25mm. wide, 3mm thick reeded glass fixed with wooden beading
of size 10mm wide flushed to the thickness of the frame including cost of materials, labour Sqm 2134.00
charges, HOM of machineries complete as per specifications. ( excluding cost of fixtures )
Specification No. KBS 9.34, 9.42

Page 42 of 350
9.80 KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast in cement
concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of
frame, making good the damages to walls and floor as required and disposal of the debries
with lead upto 50 m. including cost of materials, labour charges, complete as per Nos 1054.00
specifications. (P.No. 57, I.No. 9.80 of PWD SR 2015-16)

9.81 KSRB 9-27.2 : Fixing of window frame in an existing opening including embeeding frame
in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement
concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of
frame, making good the damages to walls and floor as required and disposal of the debries Nos 714.00
with lead upto 50 m. including cost of materials, labour charges, complete as per
specifications.

9.82 KSRB 9-27.3 : Fixing of ventilator frame in an existing opening including embeeding frame
in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement
concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of
frame, making good the damages to walls and floor as required and disposal of the debries Nos 564.00
with lead upto 50 m. including cost of materials, labour charges, complete as per
specifications.

9.83 SOLID PANEL PVC DOOR SHUTTER Providing & fixing 30mm thick factory made rigid
foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm fro
styles and 15x15mm for top & bottom rails, covered with heat moulded PVC channel of
5mm thick sheet & 30 x 50mm wide to form styles & 5mm thick & 75mm wide PVC Sheets
for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as
gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Sqm 3193.00
Frame, Sealed to the styles & rails with 5x30mm PVC sheet beading on either side & joined
together with solvent cement adhesive etc., Complete as per manufacturers specification &
direction of Engineer-in-charge fixed to frames with 3 nos of 75 m.m Aluminium hinges.

9.84 SOLID PVC DOOR FRAME Providing & fixing factory made PVC Door frame of size
50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet
metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square
tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. Sqm 526.00
The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per
manufacturers specification & direction of Engineer-in-charge.

Page No. 57

9.85.1 SOLID PANEL PRELAM PVC DOOR SHUTTER Providing & fixing 30mm thick factory
made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19
gauge for styles and 15x15mm for top & bottom rails, covered with heat moulded
Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm
thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either
side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail,
Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sqm 4045.00
Sealed to the styles & rails with PVC Designer beading on either side & joined together with
solvent cement adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm. Aluminium hinges.
with both side prelam

Page 43 of 350
9.85.2 SOLID PANEL PRELAM PVC DOOR SHUTTER Providing & fixing 30mm thick factory
made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19
gauge for styles and 15x15mm for top & bottom rails, covered with heat moulded
Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form styles & 5mm
thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either
side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail,
Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sqm 2927.00
Sealed to the styles & rails with PVC Designer beading on either side & joined together with
solvent cement adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm. Aluminium hinges.
with one side prelam

9.86 PVC DOOR SHUTTER (Nandi or Equivalent) Supply and fixing of door shuttersmade of
rigid PVC extruded hollow section (Nandi or equivalent) o f 20mm x 200mm with the wall
thickness of 1.0mm + /0.1mm equally divided into 4nos with tongue and groove locking
arrangements. The shutter frame is made of 58x24 mm with the wall thickness of 1.5mm+/ -
0.15mm section metricut and joined at 4 corners with 125mmx225mm plastic brackets. The
Sqm 1760.00
shutter shall be horizontally reinforced with 2nos of 8mm PVC rods. Teak wood battons
shall be reinforced inside the door shutter during the fabrication of the door shutter at those
points wherever the hardware is fixed on to the door shutter.

9.87 Supply and fixing of door shutters made of rigid PVC extruded hollow section (Nandi or
equivalent) of 20mmx200mm with the wall thickness of 1.0mm+/-0.1mm equally divided
into 4nos with tongue an groove locking arrangements. The shutter frame is made of 30mm
x 79mm with the wall thickness of 1.5mm+/-0.15mm section metric cut and joined at 4
corners with 125mmx225mm plastic brackets. The shutter shall be horizontally reinforced Sqm 1950.00
with 2nos of 8mm PVC rods. Teak wood battons shall be reinforced inside the door shutter
during the fabrication of the door shutter at those points wherever the hardware is fixed on to
the door shutter.

9.88 Supply and fixing of door frame made of hollow extruded PVC Section (Nandi or
Equivalent) having dimension of 40x57mm with the wall thickness of 2mm+/-0.2mm duly
reinforced with seasoned wood plank at the hinges side. The door frame top 2corners shall m 230.00
be metric cut/ welded.
Page No. 58
9.89 Supply and fixing of door frame made of hollow extruded PVC Section (Nandi or
Equivalent) having dimension of 40x46mm with the wall thickness of 2mm+/-0.2mm duly
reinforced with seasoned wood plank at the hinges side. The door frame top 2 corners shall m 220.00
be metric cut/ weilded .
9.90.1 Providing and fixing factory made splendoor of solid core single leaf rigid composite
polymer laminated sal wood, door shutter of required thickness, manufactured out of solid
core door conforming to IS 2202 (Part-1) 1991, laminated with 0.8 mm thick polymer,
termite, water resistant and fire retardant with superior gluing based on vacuum lamination
technology and with various pre moulded design on both faces conforming to IS 6307-1985,
using adhesive conforming to IS 4835-1979 and door shuters tested in conformation to IS
4020-1994. The finish of shutters will be TEADK/OAK/CEDAR/ROSE WOOD/ Sqm 3200.00
WALNUT, plain colurs WHITE/IVORY/BEIGE/LIGHT GREY. Excluding cost of fixtures
and inclusive of supply of shutters to respective work spot.
with door shutter 30mm thick

Page 44 of 350
9.90.2 Providing and fixing factory made splendoor of solid core single leaf rigid composite
polymer laminated sal wood, door shutter of required thickness, manufactured out of solid
core door conforming to IS 2202 (Part-1) 1991, laminated with 0.8 mm thick polymer,
termite, water resistant and fire retardant with superior gluing based on vacuum lamination
technology and with various pre moulded design on both faces conforming to IS 6307-1985,
using adhesive conforming to IS 4835-1979 and door shuters tested in conformation to IS
4020-1994. The finish of shutters will be TEADK/OAK/CEDAR/ROSE WOOD/ Sqm 3650.00
WALNUT, plain colurs WHITE/IVORY/BEIGE/LIGHT GREY. Excluding cost of fixtures
and inclusive of supply of shutters to respective work spot.
with door shutter 35mm thick

9.91 Providing and fixind of factory made 30mm P.V.C rigid foam (FOREX) PANEL DOORS
Rajashree made from MS tube of 19 guage, size of 19mm x 19mm and covered with heat
moulded PVC C Channel of 5 mm thick and width of 50mm to form styles and rails. The
inner panel should be inserted in between the frame with 5mm thick PVC rigid foam sheet, Sqm 2520.00
welded/sealed to the styles and rails along with 5mm PVC, beeding on all and either sides.
The vertical tubes may be filled with suitable wood material to further enhance the screw
holding capacity

9.92 Providing and fixing PVC Hollow Door Frame of the size 50x47mm with a wall thickness of
5mm, made out of extruded 5mm rigid PVC foam sheet, mitre cut at two corners and joined
with 2 Nos. of 150mm long brackets of 15x15mm M.S. Square tube. The two vertical door
profiles are to be reinforced with 19x19 mm M.S. Square tube of 19 gauge, EPDM rubber
gasket weather seal to be provided through out the frame. The door screws through the frame m 390.00
by using PVC fasteners. A minimum of 4 Nos of screws to be provided for each vertical
member & minimum 2 Nos. for horizontal member.

9.93 Providing and fixing factory made single leaft rigid GRP Sandwich composite door shutter
of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-
stabilized Isopthalic Gelcoat and on layer of 45 gsm E-Glass Chopped strand Mat (CSM),
impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than
1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density
of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned
Salwood block of cross section not less than 28mmx32mm and also necessary salwood
reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be Sqm 3200.00
provided. A structural adhesive compatible with EPS foam shall be used for bonding the
core material, the Salwood reinforcement and the skins. The material and process for
manufacturing the door shutters shall confirm to RV/TIFAC Composites Design centre
Standards and specifications and the door shutters tested in confiramation to IS 4020-1994.
The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour
using high quality pigments. Exclusing cost of fixtures and inclusive of supply of shutters to
respective work spot.

Page No. 59
9.94 Providing and fixing factory made single leaf rigid GRP Sandwich composite door shutter of
40 mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-
stabilized Isopthalic Gelcoat and one layer of 450 gns E-Glass Chopped Strand Mat (CSM),
impregnated with orthopthalic polyester resin. The thickness of the skins shall not be less
than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 37mm thickness and a
density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of
Seasoned Salwood block of cross section not lessthan 36mmx32mmand also necessary
salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles,
etc. shall be provided. A structural adhesive compatible with EPS foam shall be used for
bonding the core material, the salwood reinforement and the skins. The material and process Sqm 4000.00
for manufacturing the door shutters shall confirm to RV-TIFAC Composites Design Centre
Standards and specifications and the door shutters tested in confiramation to IS 4020-1994.
The finish of shutter will be plain coulur White/IVORY/Beige/Light Grey or any other
colour using high quality pigments. Excluding cost of fixtures and inclusive of supply of
shutters to respective work spot. (P.No.60, I.No.9.94 of PWD SR 2015-16)

Page 45 of 350
9.95 Providing and fixing 65mmx90mm GRP Doorframe fabricated using E-Glass Chopped
Strand Mat (CSM). U.V-stabilized Isopthalic Gelcoat and Isopthalic resin. The thickness of
the GRP skin shall not be less than 2.0 mm. The doorframe consists of four segmens, which
are provided with plug-in-socket arrangement in-situ in the mould. The segments are
plugged in and are joined together by means of screws. The GRP frame shall be provided
m 480.00
with wooden reinforcement of 6 locations fro high screw holding capacity for fixing metallic
hold fast and shall be consolidated by filling with medium density foam/Plaster with fibre
reinforcement. Six Numbers of 260mmx25mmx5mm size S shaped M.S. flat hold fast shall
be provided with the frame.

9.96 Providing and fixing 65mmx125mm GRP Doorframe fabricated using E-Glass Chopped
Strand Mat (CSM) U.V- stabilized Isopthalic Gelcoat and Isopthalic resin. The thickness of
the GRP skin shall not be less than 2.0mm. The doorframe consists of four segments, which
are provided with plug-in-socket arrangement in-situ in the mould. The segments are
plugged in and are joined together by means of screws. The GRP frame shall be provided
with wooden reinforcement on 6 locations for high screw holding capacity for fixing m 565.00
metalling hold fast and shall be consolidated by filling with medium density foam/Plaster of
Paris with fibre reinforcement. Six Numbers of 260mmx25mmx5mm size S shaped M.S. flat
hold fast shall be provided with the frame.

Page No. 60
9.97 Providing G.R.P. unbreakable railings available in a wide range of attractive colours made
out of cross section >70mmx64mm of standard length 7 feet (approximate 3.6Kg/m). The
material and process for manufacturing railings shall confirm to RV-TIFAC composites Each 440.00
design centre standards and specifications.
9.98 Providing and fixing RCC door frames factory manufactured, with C.C. 1:1 1/2 :3 reinforced
with 3 Nos. of 6 mm dia. Main bars and 6 mm dia. Stirrups welded at 30 cm C/C, vibrating,
curing including cost of steel and fabrication charges having 3 Nos. of hinges with 20mm x
3mm M.S. flat welded with required iron rods and flats with drilling and fixing 4 No.of flat
screw nuts each in concrete for fixing hinges and making necessary provision in concrete for
m 220.00
fixing aldrops, tower bolts etc., including cost of one coat of oil based enamel primer, 4
No.of hold fasts, 3 Nos. ISS Iron oxidised hinges necessary metal screws etc., complete.
60mm x 100 mm size-Door frames.

9.99 Providing and fixing masquito mesh to mesh to windows with 7.5 mm to 1.25 mm thick
Sqm 740.00
Honne wood petties including labour charges etc., complete.
9.100 Providing and fixing require line and slope roofing with semi-corrugated PVC roofing sheets
of industrial profile 250/40 in 2.00 mm thick white colour, fire and heat resistant having
width of 1.054 mtrs. fixed with self tapping screws with washers, over the existing purlins, Sqm 850.00
rafters and trusses including cost of materials, labour, complete as per specification.

9.101 Providng and fixng Teak Wood Hand railing to stair case using bulusters of sections 40mm
x 25mm as per design drawing No: 11863 / railings issued by the Principal Chief Architect
and fixing it to the steps using anchor bolts and necessary adhesive materiasl and fixing
T.W.handrail of section 75 x 75 mm to bulusters and finishing the same by using colourless
polish etc., complete. The work includes cost of all materials, labour charges for all items of m 9192.00
work, hire charges for welding, cutting and grinding equipment, and electricity charges, with
lead and lift, loading and unloading charges, etc., complete as per drawing and specification

9.102 Providing Maranthi wood frames of doors, windows, clear story windows, ventilation and
other frames, wrought, framed or assembled including making plaster grooves (excluding
cost of concrete cement and side clamps) but including cost of materials, labours, HOM of cum 50841.00
machineries complete as per specifications.
9.103 Providing & Fixing Mosquito mesh shutters made out of Stainless Steel mosquito proof
mesh with 95% & above visibility which is fixed to the powder coated aluminium frame
32mm thick of approved shade. The work including fixing the shutters with necessary Sqm 3200.00
accessories, to complete as per specification including the labour charges for fixing the
shutter to the existing frames.
Page No. 61

Page 46 of 350
9.104 Providing & Fixing Mosquito mesh shutters made out of Stainless Steel mosquito proof
mesh with 95% & above visibility which is fixed to the powder coated aluminium frame
20mm thick of approved shade. The work including fixing the shutters with necessary Sqm 2600.00
accessories, to complete as per specification including the labour charges for fixing the
shutter to the existing frames.
9.106.1 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 3420.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 30mm thick both side teak

9.106.2 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 2875.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 30mm thick one side teak and one side commercial

9.106.3 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 2026.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 30mm thick both side commercial

9.106.4 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 3662.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 35mm thick both side teak

9.106.5 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 3068.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 35mm thick one side teak and one side commercial

9.106.6 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 2269.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 35mm thick both side commercial. (P. No. 62/ I.No. 9.106.6 of CSR
2015-16)

9.106.7 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 3784.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 40mm thick both side teak

9.106.8 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 3299.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 40mm thick one side teak and one side commercial

Page 47 of 350
9.106.9 Providing and fixing flush door shutter made out of solid core black board type, well
seasoned chemically treated hard wood battens and internal frame with minimum 45 mm
wide wooden frame all-round door shutters covered with cross bonded wooden sheets (core
veneer) hot pressed and fastened on both sides of the door using liquid phenol formaldehyde sqm 2511.00
resin as per IS specification 2202 (Part-I) 1991. From manufacturer (Factory) complete as
per specification. - 40mm thick both side commercial

9.107 Providing and fixing to the existing door frames, factory made single
leaf HDF – Teak Veneer skin sandwich composite door shutter of
40 mm thickness made out of honeycomb of 34 mm thick and surrounded
by good quality properly seasoned wooden reinforcements of size
33 mm X 65 mm for fixing fixtures such as tower bolts, aldrops, handles
etc., and laminated on either sides with 3 mm thick wood grain finish
good quality HDF-Teak Veneer skins, using structural bonding material
compatible with honeycomb core, wood and HDF- Teak Veneer skin and
the whole assembly is bonded together at high temperature and pressure
using 650 tonnage heated compression moulding press.All the four sides Sqm 2356.00
of the door shutter are applied with two coats of UV stabilized polyester
resin putty to completely cover and seal the wood from water ingression.
The material and process for manufacturing the door shall confirm to RV-TIFAC composites
design centre standards and specification and
the door shutters tested in confirmation to IS4020-1994, including cost
of all materials, labour charges, HOM and machineries etc. complete
but excluding the cost of fixtures.

9.108
Providing and fixing to the existing door frames, factory made
single leaf HDF skin sandwich composite door shutter of 40 mm
thickness made out of honeycomb of 34 mm thick and surrounded
by good quality properly seasoned wooden reinforcements of size
33 mm X 65 mm for fixing fixtures such as tower bolts, aldrops, handles
etc., and laminated on either sides with 3 mm thick wood grain finish
good quality HDF skins, using structural bonding material compatible
with honeycomb core, wood and HDF skin and the whole assembly is
bonded together at high temperature and pressure using 650 tonnage
Sqm 1716.00
heated compression moulding press. The HDF Composite door surface
is coated with 2 coats of high quality primer.The front and back surfaces
of the door shutter and all the four sides are painted with two coats of
high quality paint of any desired colour. The material and process for
manufacturing the door shall confirm to RV-TIFAC composites design
centre standards and specification and the door shutters tested in
confirmation to IS4020-1994, including cost of all materials, labour
charges, HOM and machineries etc. complete but excluding the cost
of fixtures.

Page No. 62
9.109 Providing and fixing to the existing door frames, factory made single
leaf HDF – Teak Veneer skin sandwich composite door shutter of
32 mm thickness made out of honeycomb of 29 mm thick and surrounded
by good quality properly seasoned wooden reinforcements of size
28 mm X 40 mm for fixing fixtures such as tower bolts, aldrops, handles
etc., and laminated on either sides with 3 mm thick wood grain finish
good quality HDF- Teak Veneer skins, using structural bonding material
compatible with honeycomb core, wood and HDF- Teak Veneer skin and
the whole assembly is bonded together at high temperature and pressure
using 650 tonnage heated compression moulding press. All the four sides Sqm 2384.00
of the door shutter are applied with two coats of UV stabilized polyester
resin putty to completely cover and seal the wood from water ingression.
The material and process for manufacturing the door shall confirm to
RV-TIFAC composites design centre standards and specification and
the door shutters tested in confirmation to IS4020-1994, including cost
of all materials, labour charges, HOM and machineries etc. complete
but excluding the cost of fixtures.

Page 48 of 350
9.110 Providing and fixing to the existing door frames, factory made single
leaf HDF skin sandwich composite door shutter of 32 mm thickness
made out of honeycomb of 26 mm thick and surrounded by good quality
properly seasoned wooden reinforcements of size 25 mm X 65 mm for
fixing fixtures such as tower bolts, aldrops, handles etc., and laminated on either sides with 3
mm thick wood grain finish good quality HDF
skins, using structural bonding material compatible with honeycomb
core, wood and HDF skin and the whole assembly is bonded together at
high temperature and pressure using 650 tonnage heated compression
moulding press. The HDF Composite door surface is coated with 2 coats Sqm 1610.00
of high quality primer.The front and back surfaces of the door shutter
and all the four sides are painted with two coats of high quality paint
of any desired colour. The material and process for manufacturing the
door shall confirm to RV-TIFAC composites design centre standards and
specification and the door shutters tested in confirmation to IS4020-1994,
including cost of all materials, labour charges, HOM and machineries
etc. complete but excluding the cost of fixtures.

9.111 Providing and fixing to the existing door frames, factory made single
leaf HDF skin sandwich composite door shutter of 32 mm thickness
made out of honeycomb of 26 mm thick and surrounded by good quality
properly seasoned wooden reinforcements of size 25 mm x 65 mm for
fixing fixtures such as tower bolts, aldrops, handles etc., and laminated
on either sides with 3 mm thick wood grain finish good quality HDF
skins, using structural bonding material compatible with honeycomb
core, wood and HDF skin and the whole assembly is bonded together at
high temperature and pressure using 650 tonnage heated compression
moulding press. The HDF Composite door surface is coated with 2 coats Sqm 1854.00
of high quality primer.The front and back surfaces of the door shutter
and all the four sides are painted with two coats of high quality paint
of any desired colour. The material and process for manufacturing the
door shall confirm to RV-TIFAC composites design centre standards and
specification and the door shutters tested in confirmation to IS4020-1994,
including cost of all materials, labour charges, HOM and machineries
etc. complete but excluding the cost of fixtures.

Page No. 64

10.0 10.WATER PROOFING

10.1 KSRB 10-2 : Providing and laying in position yelahanka tiles of size 250 x 250mm of
approved quality and make, over a bed of cement mortar 1:3 an average thickness 25mm
over weather proof course and pointed with cement mortar 1:3 mix with red oxide including Sqm 804.00
curing cost of materials, labour complete as per specifications. Specification No. KBS

10.2 KSRB 10-3 : Providing and laying integral cement based waterproofing treatment including
preparation of surface as required for treatment of roofs, balconies, terraces etc., consisting
of following application. (a) Applying and grouting a slurry coat of neat cement using 2.75
kg/sqm of cement admixed with proprietary water proofing compound conforming to
IS:2645 over the RCC slab after cleaning the surface before treatment. (b) Laying cement
concrete using broken brick bats 25mm to 100mm size with 50% of cement mortar 1:5
admixed with proprietary water proofing compound conforming IS:2645 over 20mm thick
layer of cement mortar 1:5 admixed with proprietary water proofing compound to required Sqm 904.00
slope and treating similarly the adjoining walls upto 300mm height including rounding off
junctions of walls and slabs. (c) After two days of proper curing, applying a second coat of
cement lurry admixed with proprietary water proofing compound (d) Finishing the surface
with 20mm thick jointless cement mortar of mix 1:4 admixed with proprietary water
proofing compound and finally finishing the surface with trowel and neat cement slurry and
making of 300x300mm square. (e) The whole terrace so finished shall be flooded with water
for a minimum period of two weeks for curing and for final test including cost of materials,
labour complete as per specifications. (P.No. 66, I.No. 10.2 of PWD SR 2015-16)

Page 49 of 350
10.3 KSRB 10-4 : Providing and laying four courses water proofing treatment with bitumen felt
over roof consisting of first and third courses of blown and / or residual bitumen applied hot
at 1.45 kg / sqm of area for each course second course of roofing felt Type - 3 grade-I
( hessian based self finish bitumen felt ) and forth and final course of stone grit 6mm and
down size or pea sized gravel spread at 0.06 cum. / sqm including preparation of surface but Sqm 309.00
excluding grading complete with bitumen felt ( hessian based ) Type - 3 grade-I blown or /
and residual bitumen applied hot 1.4 kg / sqm including cost of materials, labour complete as
per specifications. KBS 10.4.3

10.4 KSRB 10-5 : Providing and laying six courses water proofing treatment with bitumen felt
over roof consisting of first, third and fifth courses of blown and / or residual bitumen
applied hot at 1.45 kg, 1.2kg and 1.7kg / sqm of area respectively, second and fourth courses
of roofing felt Type -2 grade-I ( fibre based self finish bitumen felt ) and sixth and final Sqm 550.00
course of stone grit 6mm and down size or pea sized gravel spread at 0.06 cum. / sqm
including preparation of surface, excluding grading but including cost of materials, labour
complete as per specifications. KBS 10.4.3

Page No. 66
10.5.1 Waterproofing of RCC Terrace / podium slab / toilet / utilities / water retaining structure by
preparing the surface by chipping and cleaning and Grouting of Honey comb, voids,cracks /
construction joints with cement slurry (1kg cement added in 10 ltr of water) added with
100gm of inorganic accelerator, followed by spraying of liquid biological modified alkaline
earth silicates @ 0.40 ltr per sqm on whole surface to reduce the micro porosity and allowing
it to dry, curing the surface for the silicates to penetrate deeper into the concrete and
spraying waterproofing impregnate liquid containing silane and silanol linear copolymer @ sqm 590.00
0.50 ltr per sqm and finally applying polymer slurry made out of cross linked acrylic /
styrene / butadiene & cement in the ratio of 1:0.1, @0.50kg/sqm on the whole surface,
including all labour charges tools and equipments, all complete as per the specification

10.5.2 Bore Packing : filling the bore wherever necessary with polymer modified concrete and
brushing one coat of acrylic copolymer cross linked formulation on the bore. including all
labour charges tools and equipments, all complete as per the manufacturer sqm 242.00

10.5.3 Extra for water proofing the inside surface of tanks (OHT & UGT) - applying of modified
polymers soft acrylic esters coat @0.40 kg/sqm in 2 coats including all labour charges tools
and equipments, all complete as per the specification. sqm 285.00

10.6 Providing and fixing food grade epoxy painting to over head tank and sump tank after
cleaning and drying including pumping and bailing out of water, including cost of all Sqm 100.00
materials labour lead and lifts etc., complete
10.7 Cleaning RCCsump tanks and RCC overhead tanks with mechanical dewatering including
removal of sludge, mud, dirt, algea etc and cleanuing the wall surface of tanks using high
pressure jet, vacuum cleaning and spraying anti bacterial treatment to the wall and ceiling
surfaces and UV treatment, including removing of sludge etc., using suitable coconut L 0.50
broomstick, squeesers / wipers / rubber brushes, coir brushes, plastic buckets, mugs,
dewatering using motor with portal arrangement, hose pipe etc., complete including all
safety measures.

10.8 Providing and applying composite water proofing compound as impregnate only on wet
surfaces to arrest leaks in surfaces such as roof cealing, internal and external walls, flooring
and other surfaces apart from water tanks, sumps, reservoirs, by mixing the composite
waterproofing compound with water in ratio of 1:10 to make a workable slurry and pouring
it on all cleaned and prepared corners and disturbed area and further mixing in the ratio 1:20
sqm 550.00
AND pouring it on the prepared surface by cleaning the surface with etchant chemical from
dirt foreign materials etc., and allowing it to be there upto 3 hours and then cleaning the
same using water complete as per specification so that the surface is got back and ready to
use after 4 hours.

Page No. 67

Page 50 of 350
10.9 Providing and applying Polymer based water proofing slurry having
chemical resistance properties, capable of withstanding a Temperature
of 200 DegC for Protective Negative coating for Water Dampness &
seepages, comprising of Portland cement, Lime stone, Silica sand,
Alumina cement, sodium aluminate in the form of powder composition
at 3.30 kgs mixed with 1.0 liter of Acrylic emulsion, applied on
0.64 Sqm area/liter of slurry on a cleaned surface free of loose materials Sqm 3100.00
etc, complete on all masonry structures, overhead tank, sump tank,
water closet areas, sunken slab and other such areas, filling tile joints,
capable of Self curing within 3 to 4 hours of its application in normal
atmospheric condition, including cost of all materials, labour charges,
HOM and machineries etc., complete.

10.10 Providing and applying Polymer based instant running water leak arrester
in civil works using mixture capable of withstanding a temperature
of 200 Deg C comprising of Portland cement, Lime stone, Silica
sand, Alumina cement, Sodium aluminate, Calcium oxide in the form
of powder composition of 1.00kg mixed with 250ml water, applied on a
kg 2100.00
cleaned surface free of loose materials, dust etc., for cavities and also
for damaged areas in all masonry and concrete structures, for rapid
hardening and leak arresting including cost of all materials, labour
charges, HOM and machineries etc., complete.

10.11 Providing and applying water proofing in two coats of 300 microns thickness on all surfaces
like concrete, Metal, Plastic , Asbestos, Wood, Cloth canopy using Heat refractive
compound made out of Vinyl Acetate copolymer latex, Water, Titanium Dioxide, Barium
metaborate, Ceramic Microsphere powder, Mica, Propylene Glycol in suitable proportions
and the surface to be treated should be cleared of loose particles/dust/fungus etc and kept dry Sqm 900.00
before the application of heat refractive compound, including cost of all materials, labour
charges, HOM and machineries etc., complete.

Page No. 68

11.0 11.DRAINAGE WORK

11.1 KSRB 12-1.1 : Providing and laying in position to required level or slope 100mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 229.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

11.2 KSRB 12-1.2 : Providing and laying in position to required level or slope 150mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 353.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

11.3 KSRB 12-1.3 : Providing and laying in position to required level or slope 200mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 478.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7 200mm

11.4 KSRB 12-1.4 : Providing and laying in position to required level or slope 230mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 523.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

11.5 KSRB 12-1.5 : Providing and laying in position to required level or slope 250mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 564.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

Page 51 of 350
11.6 KSRB 12-1.6 : Providing and laying in position to required level or slope 300mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 624.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

11.7 KSRB 12-1.7 : Providing and laying in position to required level or slope 350mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 670.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

11.8 KSRB 12-1.8 : Providing and laying in position to required level or slope 400mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 730.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

11.9 KSRB 12-1.9 : Providing and laying in position to required level or slope 450mm internal
diameter salt glazed stoneware pipes grade A and jointing with stiff mixture of cement
mortar in proportion of 1:1, testing of pipes and joints,including cost of materials, labour m 854.00
charges complete as per specifications. Specification No. KBS 12.2.5 / 12.7

Page No. 70
11.10 KSRB12-2.1 : Providing and laying in position plain cement concrete M7.5 40mm and down
size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms thick,
well compacted, for 100mm internal diameter stoneware pipes including cost of materials, m 232.00
labour charges, HOM of machinery, curing complete as per specifications Specification No.
KBS 4.1 / 4.2
11.11 KSRB 12-2.2 : Providing and laying in position plain cement concrete M7.5 40mm and
down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms
thick, well compacted, for 150mm internal diameter stoneware pipes including cost of m 389.00
materials, labour charges, HOM of machinery, curing complete as per specifications
Specification No. KBS 4.1 / 4.2
11.12 KSRB 12-2.3 : Providing and laying in position plain cement concrete M7.5 40mm and
down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms
thick, well compacted, for 200mm internal diameter stoneware pipes including cost of m 432.00
materials, labour charges, HOM of machinery, curing
11.13 KSRB 12-2.4 :Providing and laying in position plain cement concrete M7.5 40mm and down
size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms thick,
well compacted, for 230mm internal diameter stoneware pipes including cost of materials, m 466.00
labour charges, HOM of machinery, curing
11.14 KSRB 12-2.5 : Providing and laying in position plain cement concrete M7.5 40mm and
down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms
thick, well compacted, for 250mm internal diameter stoneware pipes including cost of m 486.00
materials, labour charges, HOM of machinery, curing complete as per specifications
Specification No. KBS 4.1 / 4.2
11.15 KSRB 12-2.6 : Providing and laying in position plain cement concrete M7.5 40mm and
down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms
thick, well compacted, for 300mm internal diameter stoneware pipes including cost of m 554.00
materials, labour charges, HOM of machinery, curing complete as per specifications
Specification No. KBS 4.1 / 4.2 300mm
11.16 KSRB 12-2.7 : Providing and laying in position plain cement concrete M7.5 40mm and
down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms
thick, well compacted, for 350mm internal diameter stoneware pipes including cost of m 622.00
materials, labour charges, HOM of machinery, curing complete as per specifications
Specification No. KBS 4.1 / 4.2
11.17 KSRB 12-2.8 : Providing and laying in position plain cement concrete M7.5 40mm and
down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms
thick, well compacted, for 400mm internal diameter stoneware pipes including cost of m 690.00
materials, labour charges, HOM of machinery, curing complete as per specifications
Specification No. KBS 4.1 / 4.2

Page 52 of 350
11.18 KSRB 12-2.9 : Providing and laying in position plain cement concrete M7.5 40mm and
down size graded granite metal, machine mixed concrete laid in layers not exceeding 15 cms
thick, well compacted, for 450mm internal diameter stoneware pipes including cost of m 753.00
materials, labour charges, HOM of machinery, curing complete as per specifications
Specification No. KBS 4.1 / 4.2
11.19 KSRB 12-3.1 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 100mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 341.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.20 KSRB 12-3.2 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 150mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 551.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.21 KSRB 12-3.3 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 200mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 649.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.22 KSRB 12-3.4 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 230mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 747.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.23 KSRB 12-3.5 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 250mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 758.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.24 KSRB 12-3.6 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 300mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 874.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.25 KSRB 12-3.7 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 350mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 1000.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.26 KSRB 12-3.8 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 400mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 1125.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

11.27 KSRB 12-3.9 : Providing and laying in position plain cement concrete of mix M 7.5 using
40mm and down size graded granite / trap metal for haunching of 450mm internal diameter
stoneware pipes, concrete machine mixed laid in layers not exceeding 15 cms thick, well
compacted, including cost of materials, labour charges, form work, HOM of machinery, m 1248.00
curing complete as per specifications. Specification No. KBS 4.1 / 4.2

Page 53 of 350
11.28 KSRB 12-4.1 : Providing and laying in position plain cement concrete of M 7.5 using 40mm
and down size graded granite / trap metal for surrounded encasing 100mm internal diameter
stoneware pipes, concrete machine mixed well compacted including cost of materials, labour m 725.00
charges, form work, HOM of machinery, curing complete as per specifications. Specification
No. KBS 4.1 / 4.2
11.29 KSRB 12-4.2 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 150mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 881.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.30 KSRB 12-4.3 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 200mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 1027.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.31 KSRB 12-4.4 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 230mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 1122.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.32 KSRB 12-4.5 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 250mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 1190.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.33 KSRB 12-4.6 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 300mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 1355.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.34 KSRB 12-4.7 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 350mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 1545.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.35 KSRB 12-4.8 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 400mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 1728.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.36 KSRB 12-4.9 : Providing and laying in position plain cement concrete of M 7.5 using
40mm and down size graded granite / trap metal for surrounded encasing 450mm internal
diameter stoneware pipes, concrete machine mixed well compacted including cost of m 1904.00
materials, labour charges, form work, HOM of machinery, curing complete as per
specifications. Specification No. KBS 4.1 / 4.2
11.37 KSRB 12-5.1 : Constructing brick masonry circular type manhole 0.91 m internal dia at
bottom,0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50
class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement
mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using
40mm and downsize granite metal and making necessary channel in cement concrete M 50
with 20mm and downsize granite metal finished with a floating coat of neat cement, with
S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre
confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in Nos 13577.00
cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing
centering, shuttering including cost of materials, labour charges, HOM of mechineries
complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the
external surface shall be paid seperately ) Specification No. KBS 12.4

Page No. 71

Page 54 of 350
11.38 KSRB 12-5.2 : Constructing brick masonry circular type manhole 1.67 m internal dia at
bottom, 0.91m deep and 0.56m dia at top with table moulded non-modular bricks of 50
class designation 50 in cement mortar 1:4, inside cement plastered 12mm thick with cement
mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using
40mm and downsize granite metal and making necessary channel in cement concrete M 50
with 20mm and downsize granite metal finished with a floating coat of neat cement, with
S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diametre
confirming IS :12592, total weight cover and frame to be not less than 182 kg, fixed in Nos 21125.00
cement concrete 1:2:4, 20mm and downsize broken granite metal, providing and removing
centering, shuttering including cost of materials, labour charges, HOM of mechineries
complete as per specifications. (Excavation, footrests and 12mm thick cement plaster on the
external surface shall be paid seperately ) Specification No. KBS 12.4

11.39 KSRB 12-5.3 : Constructing brick masonry circular type manhole 1.22 m internal dia at
bottom, 1.68 m deep and 0.56m dia at top, with table moulded and non modular bricks of
class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement
mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using
40mm and down size granite metal and making necessary channel in cement concrete M 15
with 20mm and down size granite metal, finished with a floating coat of neat cement, with
S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter
confirming to IS :12592, total weight length of cover and frame to be not less than 182 kg, Nos 26124.00
fixed in cement concrete M 15 20mm and down size broken granite metal, providing and
removing centering, shuttering including cost of materials, labour charges, HOM of
mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement
plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4

11.40 KSRB 12-5.4 : – Constructing brick masonry circular type manhole 1.22 m internal dia at
bottom, 2.29m deep and 0.56m dia at top, with table moulded and non modular bricks of
class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement
mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 using
40mm and down size granite metal and making necessary channel in cement concrete M 15
with 20mm and down size granite metal, finished with a floating coat of neat cement, with
S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm internal diameter
confirming to IS :12592, total weight length of cover and frame to be not less than 182 kg, Nos 31438.00
fixed in cement concrete M 15 20mm and down size broken granite metal, providing and
removing centering, shuttering including cost of materials, labour charges, HOM of
mechineries complete as per specifications. ( Excavation, footrests and 12mm thick cement
plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4

11.41 KSRB 12-5.5 : Constructing brick masonry circular type manhole 1.52 m internal dia at
bottom, 2.30m deep and 0.56m dia at top, with table moulded and non-modular bricks of
class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement
mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 mixed
using 40mm and down size granite metal and making necessary channel in cement concrete
1:2:4 mix with 20mm anddown size granite metal, finished with a floating coat of neat
cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm
internal diameter confirming to IS :12592, total weight length of cover and frame to be not Nos 43011.00
less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal,
providing and removing centering, shuttering including cost of materials, labour charges,
HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick
cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4

Page 55 of 350
11.42 KSRB 12-5.6 :Constructing brick masonry circular type manhole 1.52 m internal dia at
bottom, 4.18m deep and 0.56m dia at top, with table moulded and non-modular bricks of
class designation 50 in cement mortar 1:4, inside cement plaster 12mm thick with cement
mortar 1:3, finished with a floating coat of neat cement, foundation concrete M 10 mixed
using 40mm and down size granite metal and making necessary channel in cement concrete
1:2:4 mix with 20mm anddown size granite metal, finished with a floating coat of neat
cement, with S.F.R.C. cover and frame ( heavy duty, HD-20 grade designation) 560mm
internal diameter confirming to IS :12592, total weight length of cover and frame to be not Nos 82331.00
less than 182 kg, fixed in cement concrete M 15 20mm and down size broken granite metal,
providing and removing centering, shuttering including cost of materials, labour charges,
HOM of mechineries complete as per specifications. ( Excavation, footrests and 12mm thick
cement plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4

11.43 KSRB 12-5.7 : Constructing circular type manhole 1500mm internal dia at bottom 2.50m
deep 525mm dia at top, in brick masonry with 1:5 cement mortar, cement plaster 1:3, finish
with a floating coat of neat cement, RCC 1:2:4 top slab using 20mm and down size granite
metal, foundation concrete M 7.5 using 40mm and down size granite metal and making
channels in cement concrete M 15 using 20mm and down size granite metal, neatly finished
Nos 44031.00
curing, fixing CI cover complete including cost of materials, labour charges, HOM of
mechineries complete as per specifications. (Excavation, footrests and 12mm thick cement
plaster on the external surface shall be paid seperately ) Specification No. KBS 12.4

Page No. 72
11.44 KSRB 12-6.1 : Providing 20mm square M.S footrest and fixing in manhole with M 10
cement concrete block of 20x20x10cms, using 20mm and down size metal of size including
cost of materials, labour charges, curing complete as per specifications. Specification No. Nos 246.00
KBS 12.4.6
11.45 KSRB 12-6.2 : Providing 20mm round M.S footrest and fixing in manhole with M 10
cement concrete block of 20x20x10cms, using 20mm and down size metal of size including
cost of materials, labour charges, curing complete as per specifications. Specification No. Nos 212.00
KBS 12.4.6
11.46 KSRB 12-6.3 : Providing cast iron footrest and fixing in manhole with M 10 cement
concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of
materials, labour charges, curing complete as per specifications. Specification No. KBS Nos 230.00
12.4.6
11.47 KSRB 12-7.1 : Making connection of drain or sewer line of size 100 to 230mm external dia
with existing manhole including breaking into and making good the walls, floors with
cement concrete M 15 with 20mm and downsize granite metal, cement plastered on both
sides of mix 1:3, finished with a floating coat of neat cement, and making necessary Nos 1734.00
channels for the drain, including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

11.48 KSRB 12-7.2 : Making connection of drain or sewer line of size 250 to 300mm external dia
with existing manhole including breaking into and making good the walls, floors with
cement concrete M 15 with 20mm and downsize granite metal, cement plastered on both
sides of mix 1:3, finished with a floating coat of neat cement, and making necessary Nos 2276.00
channels for the drain, including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

11.49 KSRB 12-7.3 : Making connection of drain or sewer line of size 350 to 450mm external dia
with existing manhole including breaking into and making good the walls, floors with
cement concrete M 15 with 20mm and downsize granite metal, cement plastered on both
sides of mix 1:3, finished with a floating coat of neat cement, and making necessary Nos 2996.00
channels for the drain, including cost of materials, labour charges, curing complete as per
specifications. Specification No. KBS

Page 56 of 350
11.50 KSRB 12-8.1 : Constructing brick masonry inspection chamber 455x610mm, and 450mm
depth, ( clear inside dimension ) for single pipeline, using table moulded non-modular
bricks of class designation 50 in cement mortar 1:5, C.I cover withframe (light duty)
455x610mm internal dimensions, total weight of cover with frame to be not less than 38 kg (
weight of cover 23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15
with 20mm and downsize granite metal, foundation concrete M 5 with 40mm and downsize Nos 7041.00
granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a
floating coat of cement on walls and bed concrete complete as per standard design including
cost of materials, labour charges, curing complete as per specifications. Specification No.
KBS

11.50.1 Constructing brick masonry inspection chamber 600x600mm, and 450mm depth, ( clear
inside dimension ) for single pipeline, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal
dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover
23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and
downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal
inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of
cement on walls and bed concrete complete as per standard design including cost of Nos. 8954.00
materials, labour charges, curing complete as per specifications. Specification No. KBS
600x600mm and 450mm depth ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover
withframe (light duty) 600x600mm. (P.No. 73/ I.No.11.50.1 of PWD SR 2015-16)

11.50.2 Constructing brick masonry inspection chamber 450x450mm, and 450mm depth, ( clear
inside dimension ) for single pipeline, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal
dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover
23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and
downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal
inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of
cement on walls and bed concrete complete as per standard design including cost of Nos. 5344.00
materials, labour charges, curing complete as per specifications. Specification No. KBS
450x450mm and 450mm depth ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover
withframe (light duty) 450x450mm (P.No. 73/ I.No.11.50.2 of PWD SR 2015-16)

Page No 73
11.50.3 Constructing brick masonry inspection chamber 450x300mm, and 450mm depth, ( clear
inside dimension ) for single pipeline, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal
dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover
23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and
downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal
inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of Nos. 3839.00
cement on walls and bed concrete complete as per standard design including cost of
materials, labour charges, curing complete as per specifications. Specification No. KBS
450x300mm and 450mm depth ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover
withframe (light duty) 450x300mm

Page 57 of 350
11.50.4 Constructing brick masonry inspection chamber 230x150mm, and 450mm depth, ( clear
inside dimension ) for single pipeline, using table moulded non-modular bricks of class
designation 50 in cement mortar 1:5, C.I cover withframe (light duty) 455x610mm internal
dimensions, total weight of cover with frame to be not less than 38 kg ( weight of cover
23kg and weight of frame 15 kg) R.C.C. top slab with cement concrete M 15 with 20mm and
downsize granite metal, foundation concrete M 5 with 40mm and downsize granite metal
inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of Nos. 1592.00
cement on walls and bed concrete complete as per standard design including cost of
materials, labour charges, curing complete as per specifications. Specification No. KBS
230x150mm and 450mm depth ( clear inside dimension ) for single pipeline, using table
moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover
withframe (light duty) 230x150mm

11.51 KSRB 12-8.1.1 : Extra for item no. KSRB 12-8.1 depth beyond 450mm and brick masonry
chamber with table moulded non modular bricks of class designation 50 in cement mortar
1:5 for every 150mm depth or part thereof including cost of materials, labour charges, curing Each 755.00
complete as per specifications. Specification No. KBS
11.52 KSRB 12-8.2 : Constructing brick masonry inspection chamber 500x700mm, and 450mm
depth, ( clear inside dimension ) for pipeline with one or two inlets, using table moulded
non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light
duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than
38 kg ( weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with cement
concrete M 15 with 20mm and downsize granite metal , foundation concrete M 5 with 40mm Each 7791.00
and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finished
smooth with a floating coat of cement on walls and bed concrete complete as per standard
design including cost of materials, labour charges, curing complete as per specifications.
Specification No. KBS

11.53 KSRB 12-8.2.1 : Extra for item no. KSRB 12-8.2 depth beyond 450mm and brick masonry
chamber with table moulded non-modular bricks of class designation 50 in cement mortar
1:5 for every 150mm depth or part thereof including cost of materials, labour charges, curing Each 837.00
complete as per specifications. Specification No. KBS
11.54 KSRB 12-8.3 : Constructing brick masonry inspection chamber 600x850mm, and 450mm
depth, ( clear inside dimension ) for pipeline with three or more inlets, using table moulded
non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light
duty) 455x610mm internal dimensions, total weight of cover with frame to be not less than
38 kg ( weight of cover 23kg and weight of frame 15 kg ) R.C.C. top slab with cement
concrete M 15 with 20mm and downsize granite metal , foundation concrete M 5 with 40mm Each 8817.00
and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finished
smooth with a floating coat of cement on walls and bed concrete complete as per standard
design including cost of materials, labour charges, curing complete as per specifications.
Specification No. KBS

Page No. 74
11.55 KSRB 12-8.3.1 : Extra for item no. KSRB12-8.3 depth beyond 450mm and brick masonry
chamber with table moulded non-modular bricks of class designation 50 in cement mortar
1:5 for every 150mm depth or part thereof including cost of materials, labour charges, curing Each 968.00
complete as per specifications. Specification No. KBS
11.56.1 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials, with 90mm outer m 481.00
dia
11.56.2 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 110mm outer m 688.00
dia
11.56.3 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 140mm outer m 1140.00
dia

Page 58 of 350
11.56.4 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 160mm outer m 1450.00
dia
11.56.5 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 200mm outer m 1838.00
dia
11.56.6 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 225mm outer m 2225.00
dia
11.56.7 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 250mm outer m 3388.00
dia
11.56.8 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 280mm outer m 4292.00
dia
11.56.9 Providing and fixing to wall, ceiling and floor unplasticised PVC pipes 10.00 kgf/sq.cm
working pressure chemp plast / Wavin or equivalent make with pipe fittings, wall clips,
making good the wall, ceiling and floor, including cost of all materials,with 315mm outer m 5455.00
dia
Page No. 75

12.0 12.SANITARY WORK

12.1 KSRB 11-1 : Providing and fixing white vitreous china clay, water closet Indian type
( Squatting pan ) of size 580mm with footrests, 100mm S or P trap, 10 litre low level, P.V.C
flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 32mm diameter
flush pipe fittings and clamps, overflow arrangements with specials and 25mm mosquito pan 3454.00
proof coupling of approved design, painting of fittings and brackets, cutting and making
good the wall and floor wherever required, including cost of materials, labour complete as
per specifications. Specification No. KBS 11

12.2 KSRB 11-2 : Providing and fixing white vitreous china clay, water closet Orissa pattern of
size 580 x 440mm with integral type footrests, 100mm S or P trap, 10 litre low level, P.V.C
flushing cistern ( all are approved make ) with fittings, C.I / M.S brackets, 32mm diameter
flush pipe fittings and clamps, overflow arrangements with special and 25mm mosquito
proof coupling of approved design, painting of fittings and brackets, cutting and making
good the wall and floor wherever required, including cost of materials, labour complete as pan 4336.00
per specifications. Specification No. KBS 11. (P.No. 77, I.No.12.2 of PWD SR 2015-16)

12.3 KSRB 11-3 : Providing and fixing white vitreous china clay, water closet Indian type
( Squatting pan ) of size 580mm with footrests, 100mm S or P trap, (approved make) cutting
and making good the wall and floor wherever required, including cost of materials, labour pan 1279.00
complete as per specifications.
12.4 KSRB 11-4 : Providing and fixing white vitreous china clay, water closet Orissa pattern of
size 580 x 440mm with integral type footrests, 100mm S or P trap, (approved make ) cutting
and making good the wall and floor wherever required, including cost of materials, labour pan 2161.00
complete as per specifications. Specification No. KBS 11

Page 59 of 350
12.5 KSRB 11-5 : Providing and fixing white vitreous china clay, water closet European type
( Pedestal type, P-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber
buffers. 10 litre low level, P.V.C flushing cistern ( all are approved make ) with fittings, C.I /
M.S brackets, 40mm diameter flush bend with fittings and clamps, overflow arrangements
with special and 25mm mosquito proof coupling of approved design, painting of fittings and Each 5130.00
brackets, cutting and making good the wall and floor wherever required, including cost of
materials, labour complete as per specifications. Specification No. KBS 11

12.6 KSRB 11-6 : Providing and fixing white vitreous china clay, water closet European type
( Pedestal type, S-trap ) with black solid plastic seat and lid, C.P brass hinges, rubber
buffers. 10 litre white glazed / vitreous china clay low level, flushing cistern ( all are
approved make ) with fittings, C.I / M.S brackets, 40mm diameter flush bend with fittings
and clamps, overflow arrangements with specials and 25mm mosquito proof coupling of Each 4955.00
approved design, painting of fittings and brackets, cutting and making good the wall and
floor wherever required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

Page No. 77
12.7 KSRB 11-7.1 : Providing and fixing white vitreous china clay, flat back, lipped front urinal
basin of 430x260x350mm with 5 litres PVC automatic flushing cistern, C.I / M.S brackets,
standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete
painting of fittings and brackets, cutting and making good the wall and floor wherever Unit 2967.00
required, including cost of materials, labour complete as per specifications. Specification No.
KBS 11

12.8 KSRB 11-7.2 : Providing and fixing white vitreous china clay, flat back, lipped front urinal
basin of 430x260x350mm in the range of two 7.5 litre P.V.C with automatic flushing
cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps painting of fittings and brackets, cutting and making good the wall and floor Unit 4126.00
wherever required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.9 KSRB 11-7.3 : Providing and fixing white vitreous china clay, flat back, lipped front urinal
basin of 430x260x350mm in the range of three with 7.5 litres PVC automatic flushing
cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps painting of fittings and brackets, cutting and making good the wall and floor Unit 5613.00
wherever required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.10 KSRB 11-7.4 : Providing and fixing white vitreous china clay, flat back, lipped front urinal
basin of 430x260x350mm in the range of four with 10 litres PVC automatic flushing cistern,
C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I.
clamps complete painting of fittings and brackets, cutting and making good the wall and Unit 6810.00
floor wherever required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.11 KSRB 11-8.1 : Providing and fixing white vitreous china clay, wall corner type, lipped front
urinal basin of size 340x410x265mm with 5 litres P.V.C automatic flushing cistern, C.I /
M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps
complete painting of fittings and brackets, cutting and making good the wall and floor Unit 2879.00
wherever required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11
Page No. 78
12.12 KSRB 11-8.2 : Providing and fixing white vitreous china clay, wall corner type, lipped front
urinal basin of size 340x410x265mm in the range of two with 7.5 litre P.V.C automatic
flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass
unions and G.I. clamps painting of fittings and brackets, cutting and making good the wall Unit 3925.00
and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

Page 60 of 350
12.13 KSRB 11-8.3 : Providing and fixing white vitreous china clay, wall corner type, lipped front
urinal basin of size 340x410x265mm in the range of three with 7.5 litre P.V.C automatic
flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass
unions and G.I. clamps painting of fittings and brackets, cutting and making good the wall Unit 4718.00
and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.14 KSRB 11-8.4 : Providing and fixing white vitreous china clay, wall corner type, lipped front
urinal basin of size 340x410x265mm in the range of four with 10 litre P.V.C automatic
flushing cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass
unions and G.I. clamps painting of fittings and brackets, cutting and making good the wall Unit 5575.00
and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

12.15 KSRB 11-9.1 : Providing and fixing white vitreous china clay, flat back or half stall urinal
basin of size 580x380x350mm with 5 litres P.V.C automatic flushing cistern, C.I / M.S
brackets, standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps C.I
dtrap with outlet grating and other couplings in C.P brass, painting of fittings and brackets, Unit 4995.00
cutting and making good the wall and floor wherever required, including cost of materials,
labour complete as per specifications.

12.16 KSRB 11-9.2 : Providing and fixing white vitreous china clay, flat back or half stall urinal
basin of size 580x380x350mm in the range of two with 7.5 litres P.V.C automatic flushing
cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps, C.I. trap with outlet grating and other couplings in C.P brass painting of Unit 8315.00
fittings and brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications. Specification No. KBS 11

12.17 KSRB 11-9.3 : Providing and fixing white vitreous china clay, flat back or half stall urinal
basin of size 580x380x350mm in the range of three with 10 litres P.V.C automatic flushing
cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps, C.I. trap with outlet grating and other couplings in C.P brass painting of Unit 11446.00
fittings and brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications. Specification No. KBS 11

Page No. 79
12.18 KSRB 11-9.4 : Providing and fixing white vitreous china clay, flat back or half stall urinal
basin of size 580x380x350mm in the range of four with 10 litres P.V.C automatic flushing
cistern, C.I / M.S brackets, standard flush pipe and C.P. brass spreaders with brass unions
and G.I. clamps, C.I. trap with outlet grating and other couplings in C.P brass painting of Unit 14514.00
fittings and brackets, cutting and making good the wall and floor wherever required,
including cost of materials, labour complete as per specifications. Specification No. KBS 11

12.19 KSRB 11-10.1 : Providing and fixing white vitreous china clay, squatting plate with 5 litre
P.V.C automatic flushing cistern including brass coupling C.I / M.S brackets, G.I flush pipe
of standard size and C.P. brass spreaders painting of fittings and brackets, cutting and Unit 3345.00
making good the wall and floor wherever required, including cost of materials, labour
complete as per specifications. Specification No. KBS 11
12.20 KSRB 11-10.2 : Providing and fixing white vitreous china clay, squatting plate in the range
of two single squatting plate with 7.5 litre P.V.C automatic flushing cistern including brass
coupling C.I / M.S brackets, G.I flush pipe of standard size and C.P. brass spreaders painting
of fittings and brackets, cutting and making good the wall and floor wherever required, Unit 5172.00
including cost of materials, labour complete as per specifications. Specification No. KBS 11

12.21 KSRB 11-10.3 : Providing and fixing white vitreous china clay, squatting plate in the range
of three single squatting plates with 10 litre P.V.C automatic flushing cistern including brass
coupling C.I / M.S brackets, G.I flush pipe of standard size and C.P. brass spreaders painting
of fittings and brackets, cutting and making good the wall and floor wherever required, Unit 6810.00
including cost of materials, labour complete as per specifications. Specification No. KBS 11

Page 61 of 350
12.22 KSRB 11-10.4 : Providing and fixing white vitreous china clay, squatting plate in the range
of four single squatting plates with one number 15 litre P.V.C automatic flushing cistern
including brass coupling C.I / M.S brackets, G.I flush pipe of standard size and C.P. brass
spreaders painting of fittings and brackets, cutting and making good the wall and floor Unit 8460.00
wherever required, including cost of materials, labour complete as per specifications.
Specification No. KBS 11

12.23 KSRB 11-11.1 : Providing and fixing white vitreous china clay, flat back wash basin size
630x450mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P.
brass waste of standard pattern, painting of fittings and brackets, cutting and making good Unit 3886.00
the wall and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11

Page No. 80

12.24 KSRB 11-11.2 : Providing and fixing white vitreous china clay, flat back wash basin size
630x450mm with a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P.
brass waste of standard pattern, painting of fittings and brackets, cutting and making good
the wall and floor wherever required, including cost of materials, labour complete as per Unit 3007.00
specifications. Specification No. KBS 11. (P.No. 81, I.No. 12.24 of PWD SR 2015-16)

12.25 KSRB 11-11.3 : Providing and fixing white vitreous china clay, flat back wash basin size
550x400mm with a pair of 15mm C.P brass pillar taps with C.I / M.S brackets, 32 mm C.P.
brass waste of standard pattern, painting of fittings and brackets, cutting and making good Unit 3734.00
the wall and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11
12.26 KSRB 11-11.4 : Providing and fixing white vitreous china clay, flat back wash basin size
550x400mm with a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P.
brass waste of standard pattern, painting of fittings and brackets, cutting and making good Unit 2856.00
the wall and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11
12.27 KSRB 11-11.5 : Providing and fixing white vitreous china clay, flat back wash basin size
450x300mm with a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P.
brass waste of standard pattern, painting of fittings and brackets, cutting and making good Unit 2629.00
the wall and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11
12.28 KSRB 11-11.6 : Providing and fixing white vitreous china clay, angle back wash basin size
600x480mm with a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P.
brass waste of standard pattern, painting of fittings and brackets, cutting and making good Unit 3133.00
the wall and floor wherever required, including cost of materials, labour complete as per
specifications.
12.29 KSRB 11-11.7 : Providing and fixing white vitreous china clay, angle back wash basin size
400x400mm with a single 15mm C.P brass pillar tap with C.I / M.S brackets, 32 mm C.P.
brass waste of standard pattern, painting of fittings and brackets, cutting and making good Unit 2850.00
the wall and floor wherever required, including cost of materials, labour complete as per
specifications. Specification No. KBS 11
12.30 KSRB 11-11.8 : Providing and fixing white vitreous china clay, surgeon type wash basin
size 660x460mm with a pair of 15mm C.P brass pillar taps with pair of elbow operated
levers, C.I / M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings
and brackets, cutting and making good the wall and floor wherever required, including cost Unit 4579.00
of materials, labour complete as per specifications. KBS 11

12.31 KSRB 11-11.9 : Providing and fixing white vitreous china clay, surgeon type wash basin
size 660x460mm with single 15mm C.P brass pillar tap with single elbow operated lever, C.I
/ M.S brackets, 32 mm C.P. brass waste of standard pattern, painting of fittings and brackets,
cutting and making good the wall and floor wherever required, including cost of materials, Unit 3980.00
labour complete as per specifications. KBS 11

Page No. 81

Page 62 of 350
12.32 KSRB 11-12.1 : Providing and fixing kitchen sink of white glazed fire clay of size
600x450x250mm with M.S / C.I brackets, C.P brass chain with rubber plug, 32 mm C.P.
brass waste, tap with union, brass stop cock complete, painting of fittings and brackets, Unit 3567.00
cutting and making good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. KBS 11
12.33 KSRB 11-12.2 : Providing and fixing kitchen sink of white glazed fire clay of size
750x450x250mm with M.S / C.I brackets, C.P brass chain with rubber plug, 32 mm C.P.
brass waste, tap with union, brass stop cock complete, painting of fittings and brackets, Unit 4044.00
cutting and making good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. KBS 11
12.34 KSRB 11-13.1 : Providing and fixing laboratory sink of white glazed fire clay of size
600x450x200mm with M.S / C.I brackets, C.P brass chain with rubber plug, 32 mm C.P.
brass waste, tap with union, brass stop cock complete, painting of fittings and brackets, Unit 3395.00
cutting and making good the wall and floor wherever required, including cost of materials,
labour complete as per specifications. KBS 11
12.35 KSRB 11-13.2 : Providing and fixing laboratory sink of white glazed fire clay of size
450x300x150mm with M.S / C.I brackets, C.P brass chain with rubber plug, 32 mm C.P.
brass waste, tap with union, brass stop cock complete, painting of fittings and brackets, Unit 3087.00
cutting and making good the wall and floor wherever required, including cost of materials,
labour complete as per specifications KBS 11
12.36 KSRB 11-14.1 : Providing and fixing stainless steel kitchen sink of size 510x1040mm bowl
depth 178mm, with drain board, M.S / C.I brackets, stainless steel plug 40 mm, painting of
fittings and brackets, cutting and making good the wall and floor wherever required, Unit 18189.00
including cost of materials, labour complete as per specifications.
12.37 KSRB 11-14.2 : Providing and fixing stainless steel kitchen sink of size 500x1000mm bowl
depth 178mm, with drain board, M.S / C.I brackets, stainless steel plug 40 mm, painting of
fittings and brackets, cutting and making good the wall and floor wherever required, Unit 9703.00
including cost of materials, labour complete as per specifications.
12.38 KSRB 11-14.3 : Providing and fixing stainless steel kitchen sink of size 400x915mm bowl
depth 160mm, with drain board, M.S / C.I brackets, stainless steel plug 40 mm, painting of
fittings and brackets, cutting and making good the wall and floor wherever required, Unit 6708.00
including cost of materials, labour complete as per specifications.
12.39 KSRB 11-15.1 : Providing and fixing 600x450mm bevelLead edge mirror of superior glass
with 6mm hard board backing and fixed to wooden cleats with C.P screws, washers, Unit 1251.00
including cost of materials, labour complete as per specifications.
12.40 KSRB 11-15.2 : Providing and fixing 450mm dia circular shape mirror with plastic moulded
frame of approved make and shade with 6mm thick hard board backing including cost of Unit 866.00
materials, labour complete as per specifications.
12.41 KSRB 11-15.3 : Providing and fixing 453x357mm dia rectangular shape mirror with plastic
moulded frame of approved make and shade with 6mm thick hard board backing including
cost of materials, labour complete as per specifications. (P.No.82, I.No. 12.41 of PWD SR Unit 1180.00
2015-16)

12.42 KSRB 11-15.4 : Providing and fixing 450x350mm dia oval shape mirror with plastic
moulded frame of approved make and shade with 6mm thick hard board backing including Unit 920.00
cost of materials, labour complete as per specifications.
Page No. 82
12.43 KSRB 11-15.5 : Providing and fixing 1500x450mm dia rectangular shape mirror with plastic
moulded frame of approved make and shade with 6mm thick hard board backing including
cost of materials, labour complete as per specifications. (P.No.83. I.No. 12.43 of PWD SR Unit 1698.00
2015-16)
12.44 KSRB 11-16 : Providing and fixing 600x120mm glass shelf supported on alluminium angle
frame with C.P brass brackets, guard rail fixed to wooden cleats with C.P. brass screws and
washers including cost of materials, labour complete as per specifications. Unit 1220.00

12.45 KSRB 11-17-1 : Providing and fixing C.P. brass towel rail 740mm length, 20mm dia with
C.P brackets, fixed to wooden cleats with C.P. brass screws including cost of materials, Unit 783.00
labour complete as per specifications.

Page 63 of 350
12.46 KSRB 11-17.2 : Providing and fixing C.P. brass towel rail 600 mm length, 20mm dia with
C.P brackets, fixed to wooden cleats with C.P. brass screws including cost of materials, Unit 710.00
labour complete as per specifications.
12.47 KSRB 11-18-1.1 : Providing and fixing sand cast iron soil waste and vent pipes 100mm dia
with spun yarn soaked in cement slurry and cement mortar 1:2 including cost of materials, m 704.00
labour, testing complete as per specifications. KBS 11-1.10
12.48 KSRB 11-18-1.2 : Providing and fixing sand cast iron soil waste and vent pipes 75mm dia
with spun yarn soaked in cement slurry and cement mortar 1:2 including cost of materials, m 679.00
labour, testing complete as per specifications.KBS 11-1.10
12.49 KSRB 11-18-1.3 : Providing and fixing sand cast iron soil waste and vent pipes 50mm dia
with spun yarn soaked in cement slurry and cement mortar 1:2 including cost of materials, m 341.00
labour, testing complete as per specifications. KBS 11-1.10
12.50 KSRB 11-18-2.1 : Providing and fixing sand cast iron soil waste bends 100 mm dia with
access door, insertion of rubber washers 3mm thick bolts and nut, with spun yarn soaked in
cement slurry and cement mortar 1:2 including cost of materials, labour, testing complete as Each 526.00
per specifications.
12.51 KSRB 11-18-2.2 : Providing and fixing sand cast iron soil waste bends 75mm dia with
access door, insertion of rubber washers 3mm thick bolts and nut, with spun yarn soaked in
cement slurry and cement mortar 1:2 including cost of materials, labour, testing complete as Each 441.00
per specifications.
12.52 KSRB 11-18-2.3 : Providing and fixing sand cast iron soil waste bends 50mm dia with
access door, insertion of rubber washers 3mm thick bolts and nut with spun yarn soaked in
cement slurry and cement mortar 1:2 including cost of materials, labour, testing complete as Each 413.00
per specifications
12.53 KSRB 11-18-3.1 : Providing and fixing sand cast iron soil waste plain bend, 100mm dia
with spun yarn soaked in cement slurry and cement mortar 1:2 including cost of materials, Each 407.00
labour, testing complete as per specifications. KBS 11-1.10
12.54 KSRB 11-18-3.2 : Providing and fixing sand cast iron soil waste plain bend, 75mm dia with
spun yarn soaked in cement slurry and cement mortar 1:2 including cost of materials, labour, Each 321.00
testing complete as per specifications KBS 11-1.10
12.55 KSRB 11-18-3.3 : Providing and fixing sand cast iron soil waste plain bend, 50mm dia with
spun yarn soaked in cement slurry and cement mortar 1:2 including cost of materials, labour, Each 343.00
testing complete as per specifications. KBS 11-1.10
12.56 KSRB 11-18-4.1 : Providing and fixing sand cast iron soil waste double equal junction of
required degree with access door 100x100x100x100mm, insertion of rubber washers 3mm
thick bolts and nuts, including cost of materials, labour, testing complete as per Each 1172.00
specifications. KBS 11-1.10
Page No. 83
12.57 KSRB 11-18-4.2 : Providing and fixing sand cast iron soil waste double equal junction of
required degree with access door 75x75x75x75mm, insertion of rubber washers 3mm thick
bolts and nuts, including cost of materials, labour, testing complete as per specifications. Each 858.00
KBS 11-1.10
12.58 KSRB 11-18-4.3 : Providing and fixing sand cast iron soil waste double equal junction of
required degree with access door 50x50x50x50mm, insertion of rubber washers 3mm thick
bolts and nuts, including cost of materials, labour, testing complete as per specifications. Each 752.00
KBS 11-1.10
12.59 KSRB 11-18-5.1 : Providing and fixing sand cast iron soil waste single equal junction of
required degree with access door 100x100x100mm, insertion of rubber washers 3mm thick
bolts and nuts, including cost of materials, labour, testing complete as per specifications. Each 1010.00
KBS 11-1.10
12.60 KSRB 11-18-5.2 : Providing and fixing sand cast iron soil waste single equal junction of
required degree with access door 75x75x75mm, insertion of rubber washers 3mm thick bolts
and nuts, including cost of materials, labour, testing complete as per specifications. KBS 11- Each 752.00
1.10
12.61 KSRB 11-18-5.3 : Providing and fixing sand cast iron soil waste single equal junction of
required degree with access door 50x50x50mm, insertion of rubber washers 3mm thick bolts
and nuts, including cost of materials, labour, testing complete as per specifications. KBS 11- Each 590.00
1.10

Page 64 of 350
12.62 KSRB 11-18-6.1 : Providing and fixing sand cast iron soil waste double unequal junction of
required degree with access door 100x100x75x75mm, insertion of rubber washers 3mm
thick bolts and nuts, including cost of materials, labour, testing complete as per Each 1179.00
specifications. KBS 11-1.10
12.63 KSRB 11-18-6.2 : Providing and fixing sand cast iron soil waste double unequal junction of
required degree with access door 100x100x50x50mm, insertion of rubber washers 3mm
thick bolts and nuts, including cost of materials, labour, testing complete as per Each 1172.00
specifications. KBS 11-1.10
12.64 KSRB 11-18-6.3 : Providing and fixing sand cast iron soil waste double unequal junction of
required degree with access door 75x75x50x50mm, insertion of rubber washers 3mm thick
bolts and nuts, including cost of materials, labour, testing complete as per specifications. Each 471.00
KBS 11-1.10
12.65 KSRB 11-18-7.1 : Providing and fixing sand cast iron soil waste single unequal junction of
required degree with access door 100x100x75mm,insertion of rubber washers 3mm thick
bolts and nuts, including cost of materials, labour, testing complete as per specifications. Each 891.00
KBS 11-1.10
12.66 KSRB 11-18-7.2 : Providing and fixing sand cast iron soil waste single unequal junction of
required degree with access door 100x100x50mm, insertion of rubber washers 3mm thick
bolts and nuts, including cost of materials, labour, testing complete as per specifications. Each 850.00
Specification No. KBS 11.1.10
12.67 KSRB 11-18-7.3 : Providing and fixing sand cast iron soil waste single unequal junction of
required degree with access door 75x75x50mm, insertion of rubber washers 3mm thick bolts
and nuts, including cost of materials, labour, testing complete as per specifications Each 604.00
Specification No. KBS 11.1.10
12.68 KSRB 11-18-8.1 : Providing and fixing sand cast iron soil waste double equal junction of
required degree 100x100x100x100mm, including cost of materials, labour, testing complete Each 933.00
as per specifications. Specification No. KBS 11.1.10
12.69 KSRB 11-18-8.2 : Providing and fixing sand cast iron soil waste double equal junction of
required degree 75x75x75x75mm, including cost of materials, labour, testing complete as Each 695.00
per specifications. Specification No. KBS 11.1.10
12.70 KSRB 11-18-8.3 : Providing and fixing sand cast iron soil waste double equal junction of
required degree 50x50x50x50mm, including cost of materials, labour, testing complete as Each 469.00
per specifications. Specification No. KBS 11.1.10
Page No. 84
12.71 KSRB 11-18-9.1 : Providing and fixing sand cast iron soil waste single equal junction of
required degree with access door 100x100x100mm, including cost of materials, labour, Each 1010.00
testing complete as per specifications. Specification No. KBS 11.1.10
12.72 KSRB 11-18-10.1 : Providing and fixing sand cast iron soil waste double unequal junction
of required degree100x100x75x75mm, including cost of materials, labour, testing complete Each 1179.00
as per specifications. KBS 11-1.10
12.73 KSRB 11-18-11.1 : Providing and fixing sand cast iron soil waste single unequal junction of
required degree 100x100x75mm, including cost of materials, labour, testing complete as per Each 534.00
specifications. KBS 11-1.10
12.74 KSRB 11-18-11.2 : Providing and fixing sand cast iron soil waste single unequal junction of
required degree 100x100x50mm, including cost of materials, labour, testing complete as per Each 541.00
specifications. KBS 11-1.10
12.75 KSRB 11-18-11.3 : Providing and fixing sand cast iron soil waste single unequal junction of
required degree 75x75x50mm, including cost of materials, labour, testing complete as per Each 457.00
specifications. KBS 11-1.10
12.76 KSRB 11-18-12.1 : Providing and fixing sand cast iron soil waste double equal invert plain
branches of required degree 100x100x100x100mm, including cost of materials, labour, Each 1074.00
testing complete as per specifications. Specification No. KBS 11.1.10
12.77 KSRB 11-18-12.2 : Providing and fixing sand cast iron soil waste double equal invert plain
branches of required degree 75x75x75x75mm, including cost of materials, labour, testing Each 724.00
complete as per specifications. Specification No. KBS 11.1.10
12.78 KSRB 11-18-12.3 : Providing and fixing sand cast iron soil waste double equal invert plain
branches of required degree 50x50x50x50mm, including cost of materials, labour, testing Each 469.00
complete as per specifications Specification No. KBS 11.1.10

Page 65 of 350
12.79 KSRB 11-18-13.1 : Providing and fixing sand cast iron soil waste single equal invert plain
branches of required degree 100x100x100x100mm, including cost of materials, labour, Each 1032.00
testing complete as per specifications. Specification No. KBS 11.1.10
12.80 KSRB 11-18-13.2 : Providing and fixing sand cast iron soil waste single equal invert plain
branches of required degree 75x75x75x75mm, including cost of materials, labour, testing Each 752.00
complete as per specifications. Specification No. KBS 11.1.10
12.81 KSRB 11-18-13.3 : Providing and fixing sand cast iron soil waste single equal invert plain
branches of required degree 50x50x50x50mm, including cost of materials, labour, testing Each 667.00
complete as per specifications. Specification No. KBS 11.1.10
12.82 KSRB 11-18-14.1 : Providing and fixing sand cast iron soil waste double unequal invert
plain branches of required degree 100x100x75x75mm, including cost of materials, labour,
testing complete as per specifications. Specification No. KBS 11.1.10 Each 1143.00

12.83 KSRB 11-18-14.3 : Providing and fixing sand cast iron soil waste double equal invert plain
branches of required degree 75x75x50x50mm, including cost of materials, labour, testing Each 611.00
complete as per specifications. Specification No. KBS 11.1.10
Page No. 85
12.84 KSRB 11-18-15.1 : Providing and fixing sand cast iron soil waste single unequal invert plain
branches of required degree 100x100x75mm, including cost of materials, labour, testing Each 534.00
complete as per specifications. Specification No. KBS 11.1.10
12.85 KSRB 11-18-15.2 : Providing and fixing sand cast iron soil waste single unequal invert plain
branches of required degree 75x75x50mm including cost of materials, labour, testing Each 457.00
complete as per specifications. Specification No. KBS 11.1.10
12.86 KSRB 11-18-16.1 : Providing and fixing sand cast iron soil waste 152mm offsets for 100mm
pipes, including cost of materials, labour, testing complete as per specifications. Each 723.00
Specification No. KBS 11.1.10
12.87 KSRB 11-18-16.2 : Providing and fixing sand cast iron soil waste 114mm offsets for 75mm
pipes, including cost of materials, labour, testing complete as per specifications. Each 443.00
Specification No. KBS 11.1.10
12.88 KSRB 11-18-16.3 : Providing and fixing sand cast iron soil waste 230 mm offsets for 75mm
pipes, including cost of materials, labour, testing complete as per specifications. Each 778.00
Specification No. KBS 11.1.10
12.89 KSRB 11-18-17.1 : Providing and fixing sand cast iron trap of 100mm dia, of self cleaning
design with screwed down or hinged grating with or without vent arm including cutting and
making good the walls and floors, cost of materials, labour, testing, complete as per Each 834.00
specifications Specification No. KBS 11.1.10. (P.No.86, I.No.12.89 of PWD SR 2015-16)

12.90 KSRB 11-18-17.2 : Providing and fixing sand cast iron trap of 75mm dia, of self cleaning
design with screwed down or hinged grating with or without vent arm including cutting and
making good the walls and floors, cost of materials, labour, testing, complete as per Each 747.00
specifications. Specification No. KBS 11.1.10
12.91 KSRB 11-18-17.3 : Providing and fixing sand cast iron trap of 50mm dia, of self cleaning
design with screwed down or hinged grating with or without vent arm including cutting and
making good the walls and floors, cost of materials, labour, testing, complete as per Each 684.00
specifications. Specification No. KBS 11.1.10
12.92 KSRB 11-18-18.1 : Providing lead caulked joints to sand cast iron / cast iron ( spun ) pipes
and fittings of 100mm dia, including cost of materials, labour, testing, complete as per Joint 105.00
specifications. Specification No. KBS 13.2.7
12.93 KSRB 11-18-18.2 : Providing lead caulked joints to sand cast iron / cast iron ( spun) pipes
and fittings of 75mm dia, including cost of materials, labour, testing, complete as per Joint 91.00
specifications specification No. KBS 13.2.7
12.94 KSRB 11-18-18.3 : Providing lead caulked joints to sand cast iron / cast iron ( spun) pipes
and fittings of 50mm dia, including cost of materials, labour, testing, complete as per Joint 77.00
specifications Specification No. KBS 13.2.7
12.95 KSRB 11-18-9.2 : Providing and fixing sand cast iron soil waste single equal junction of
required degree with access door 75x75x75mm, including cost of materials, labour, testing Each 752.00
complete as per specifications Specification No. KBS 11.1.10
Page No. 86

Page 66 of 350
12.96 KSRB 11-18-9.3 : Providing and fixing sand cast iron soil waste single equal junction of
required degree with access door 50x50x50mm, including cost of materials, labour, testing Each 590.00
complete as per specifications. Specification No. KBS 11.1.10
12.97 KSRB 11-18-10.2 : Providing and fixing sand cast iron soil waste double unequal junction
of required degree100x100x50x50mm, including cost of materials, labour, testing complete Each 1172.00
as per specifications. Specification No. KBS 11.1.10
12.98 KSRB 11-18-10.3 : Providing and fixing sand cast iron soil waste double unequal junction
of required degree 75x75x50x50mm, including cost of materials, labour, testing complete as Each 611.00
per specifications.
12.99 KSRB 11-18-19.1 : Providing and fixing M.S stays and clamps for sand cast iron pipes of
No 229.00
100mm dia including cost of materials, labour, complete as per specifications.
12.100. KSRB 11-18-19.2 : Providing and fixing M.S stays and clamps for sand cast iron pipes of
No 209.00
75mm dia including cost of materials, labour, complete as per specifications.
12.101 KSRB 11-18-19.3 : Providing and fixing M.S stays and clamps for sand cast iron pipes of
No 51.00
50mm dia including cost of materials, labour, complete as per specifications.
12.102 KSRB 11-18-14.2 : Providing and fixing sand cast iron soil waste double unequal invert
plain branches of required degree 100x100x75x75mm including cost of materials, labour, Each 1112.00
testing complete as per specifications. Specification No. KBS 11.1.10
12.103 Providing (China Clay) glazed foot rests of approved 1st quality and make conforming to ISI
specifications and fixing in CM (1:3) as directed (Rate includes cost of materials and Pair 180.00
conveyance to work spot).
12.104. Providing plastic seat with approved 1st quality and make conforming to ISI specifications
1 double flapped and fixing to English water closet with all fittings (Rate includes cost of Pair 280.00
materials, fixtures and conveyance to work spot). - WHITE
12.104. Providing plastic seat with approved 1st quality and make conforming to ISI specifications
2 double flapped and fixing to English water closet with all fittings (Rate includes cost of Pair 230.00
materials, fixtures and conveyance to work spot). - BLACK
12.105. Providing 3 cms dia GI telescopic flush tank lever of approved 1st quality and make
conforming to ISI specifications and fixing in position as directed by the Engineer. Rate Each 225.00
includes cost of materials and conveyance to work spot.
12.106. Providing vulcanizing or rubber float of approved 1st quality and make conforming to ISI
Specifications and fixing for low down cistern as directed .Rate includes cost of materials Each 180.00
and conveyance to work spot.
12.107. Providing wash basin brackets of approved 1st quality and make conforming to ISI
Specifications and fixing for low down cistern as directed .Rate includes cost of materials Pair 228.00
and conveyance to work spot.
12.108. Providing pedestal for wash basin of approved 1st quality and make conforming to ISI
Specifications and fixing for low down cistern as directed .Rate includes cost of materials Each 875.00
and conveyance to work spot.
Page No. 87
12.109. Providing and fixing white vitreous china clay urinals with flat back of approved make fixed
to wooden plugs including bends, painting white to exposed pipes etc., complete as per Each 860.00
directions.(rate includes cost of all materials and lead).A grade.
12.110. Providing white vitreous china clay Indian pattern squatting urinals with white glazed foot
rests of approved quality and make conforming to ISI specifications and fixing in Position
with M-15 as directed of size 50.8 cms X 38 cms X 10.16 cms - A Grade (Rate includes cost Each 970.00
of all materials and conveyance to work spot). (P.No. 88, I.No. 12.110 of PWD SR 2015-16)

12.111. Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100 mm dia. (P.No. 88, I.No.
Each 160.00
12.111 of PWD SR 2015-16)
12.112. Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering
1 with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead).- Each 185.00
10cms x 10cms
12.112. Providing stoneware gully trap of approved quality and make fixing in M-15 and plastering
2 with CM 1:3 wherever necessary.( Rate includes cost of all materials, fixtures and lead). - Each 270.00
15cms x 10cms

Page 67 of 350
12.113. Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and
1 construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and
fixtures and conveyance of materials to work spot). - 10cms x 7.5cms Each 250.00

12.113. Providing and fixing CI Nahani trap of approved make conforming to ISI specifications and
2 construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and
fixtures and conveyance of materials to work spot). - 12.5cms x 7.5cms Each 285.00

12.114. Cleaning the blockages of closets and soil pipes into working order with scaffolding
m 60.00
1
12.114. Cleaning the blockages of closets and soil pipes into working order without scaffolding
m 50.00
2
12.114. Cleaning the blockages of closets and soil pipes into working order underground stone ware
m 20.00
3 pipes
12.115. Providing and fixing white vitreous china clay, wall corner type, lipped front watrless
urinal basin of size 328x319x598mm C.I / M.S brackets, standard flush pipe complete unit 31048.00
painting of fittings and brackets, cutting and making good the wall and floo
12.116. Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working
1 pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for
sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and m 412.00
testing complete as per specifications. - 110mm dia
12.116. Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working
2 pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for
sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and m 666.00
testing complete as per specifications. - 140mm dia
12.116. Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working
3 pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for
sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and m 830.00
testing complete as per specifications. - 160mm dia
12.116. Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working
4 pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for
sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and m 1332.00
testing complete as per specifications. - 200mm dia
12.116. Providing and fixing to wall, ceiling and floor unplasticised PVC 6.00 kgs/sqcm working
5 pressure with pipe fittings, wall clips etc., and making good the wall, ceiling and floor for
sanitary pipelines including cost of all materials, labour charges, HOM of acquirements and m 2052.00
testing complete as per specifications. - 250mm dia

Page No. 88
13.0 13.WATER SUPPLY WORK

13.1 KSRB13-1.1 : Providing and fixing to wall, ceiling and floor galvanised / mild steel tube
15mm dia nominal bore with fittings (medium grade weight 1.27 kg/mtr) B class including
cost of all materials, labour charges, HOM of equipments and testing complete as per m 185.00
specifications. Specification No.KBS 13.2.14 / 13.8
13.2 KSRB13-1.2 : Providing and fixing to wall, ceiling and floor galvanised / mild steel tube
20mm dia nominal bore with fittings (medium grade weight 1.65 kg/mtr) B class including
cost of all materials, labour charges, HOM of equipments and testing complete as per m 224.00
specifications. Specification No.KBS 13.2.14 / 13.8
13.3 KSRB13-1.3 : Providing and fixing to wall, ceiling and floor galvanised / mild steel tube
25mm dia nominal bore with fittings (medium grade weight 2.51kg/mtr) B class including
cost of all materials, labour charges, HOM of equipments and testing complete as per m 305.00
specifications. Specification No.KBS 13.2.14 / 13.8
13.4 KSRB13-1.4 : Providing and fixing to wall, ceiling and floor galvanised / mild steel tube
32mm dia nominal bore with fittings (medium grade weight 3.23kg/mtr) B class including
cost of all materials, labour charges, HOM of equipments and testing complete as per m 350.00
specifications. Specification No.KBS 13.2.14 / 13.8

Page 68 of 350
13.5 KSRB13-1.5 : Providing and fixing to wall, ceiling and floor galvanised / mild steel tube
40mm dia nominal bore with fittings (medium grade weight 3.72 kg/mtr) B class including
cost of all materials, labour charges, HOM of equipments and testing complete as per m 435.00
specifications. Specification No.KBS 13.2.14 / 13.8
13.6 KSRB13-1.6 : Providing and fixing to wall, ceiling and floor galvanised / mild steel tube
50mm dia nominal bore with fittings (medium grade weight 5.24kg/mtr) B class including
cost of all materials, labour charges, HOM of equipments and testing complete as per m 510.00
specifications. Specification No.KBS 13.2.14 / 13.8
13.7 KSRB13-2.1 : Extra for concealed pipe including painting with anticorrosive bitumastic
paint cutting chases, making good the concrete surface, and plaster for 15mm dia nominal
bore including cost of all materials, labour charges, HOM equipment complete as per m 111.00
specifications. Specification No.KBS
13.8 KSRB13-2.2 : Extra for concealed pipe including painting with anticorrosive bitumastic
paint cutting chases making good the concrete surface and plaster for 20mm dia nominal
bore including cost of all materials, labour and HOM equipment complete as per m 111.00
specifications. Specification No.KBS
13.9 KSRB13-2.3 : Extra for concealed pipe including painting with anticorrosive bitumastic
paint, cutting chases making good the concrete surface and plaster for 25mm dia nominal
bore including cost of all materials, labour and HOM equipment complete as per m 112.00
specifications. Specification No.KBS
13.10 KSRB13-3.1: Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
15mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 149.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.11 KSRB13-3.2 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
20mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 185.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.12 KSRB13-3.3 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
25mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 267.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.13 KSRB13-3.4 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
32mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 301.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.14 KSRB13-3.5 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
40mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 377.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.15 KSRB13-3.6 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
50mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 432.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.16 KSRB13-3.7 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
65mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 651.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

Page 69 of 350
13.17 KSRB13-3.8 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
80mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid for
separately ) including cost of all materials, labour charges, HOM of equipments and testing m 821.00
complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.18 KSRB13-3.9 : Providing and fixing in trenches galvanised / mild steel tubes (medium grade)
100mm dia nominal bore with all fittings ( earth work in trenches to be measured and paid
for separately ) including cost of all materials, labour charges, HOM of equipments and m 1082.00
testing complete as per specifications. Specification No.KBS 13.2.14 / 13.6

13.19 KSRB13-3.10 : Providing and fixing in trenches galvanised / mild steel tubes (medium
grade) 150mm dia nominal bore with all fittings ( earth work in trenches to be measured and
paid for separately ) including cost of all materials, labour charges, HOM of equipments and m 1620.00
testing complete as per specifications. Specification No.KBS 13.2.14 / 13.6

Page No. 90
13.20 KSRB13-4.1 : Making connection of G.I distribution branch with G.I main of 25 to 40mm.
nominal bore, including cutting and threading the pipes, providing and fixing Tee, nuts,
labour for all item of works, testing and HOM of equipments complete as per specifications. Nos 361.00
Specification No.KBS 13.10
13.21 KSRB13-4.2 : Making connection of G.I distribution branch with G.I main of 50 to 85mm.
and 100 to 150 nominal bore, including cutting and threading the pipes, providing and fixing
Tee, nuts, labour for all item of works, testing and HOM of equipments complete as per Nos 746.00
specifications. Specification No.KBS 13.10
13.22 KSRB13-5 : Providing and fixing water meter with stop cock, jam nut, socket in G.I pipe
line including cutting and threading the pipe and making long screws including cost of all
materials, labour, HOM of equipments and testing complete as per specifications. Set 1318.00
Specification No.KBS 13.2.19 / 13.16
13.23 KSRB13-6.1-1 : Providing and fixing in position brass bib cock of approved quality 15mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 231.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3
13.24 KSRB13-6.1-2 : Providing and fixing in position brass bib cock of approved quality 20mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads
complete as per specifications. Specification No.KBS 13.2.2 / 13.3. (P.No.91/ I.No. 13.24 of Each 243.00
CSR 2015-16)
13.25 KSRB13-6.1-3 : Providing and fixing in position brass bib cock of approved quality 25mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 272.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3
13.26 KSRB13-6.2-1 : Providing and fixing in position brass stop cock of approved quality 15mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 161.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3
13.27 KSRB13-6.2-2 : Providing and fixing in position brass stop cock of approved quality 20mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 160.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3
13.28 KSRB13-6.2-3 : Providing and fixing in position brass stop cock of approved quality 25mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 158.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3
13.29 KSRB13-6.2-4 : Providing and fixing in position brass stop cock of approved quality 32mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 158.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3
13.30 KSRB13-6.2-5 : Providing and fixing in position brass stop cock of approved quality 40mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 158.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3
13.31 KSRB13-6.2-6 : Providing and fixing in position brass stop cock of approved quality 50mm
nominal bore including cost of all materials, labour and HOM of equipments with all leads Each 160.00
complete as per specifications. Specification No.KBS 13.2.2 / 13.3

Page 70 of 350
13.32 KSRB13-6.3-1 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 15mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 334.00
13.2.6 / 13.3
13.33 KSRB13-6.3-2 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 20mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 409.00
13.2.6 / 13.3 (P.No. 91, I.No. 13.33 of PWD SR 2015-16)
13.34 KSRB13-6.3-3 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 25mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 600.00
13.2.6 / 13.3. (P.No.91/ I.No. 13.34 of CSR 2015-16)

Page No. 91
13.35 KSRB13-6.3-4 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 32mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 973.00
13.2.6 / 13.3
13.36 KSRB13-6.3-5 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 40mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 1315.00
13.2.6 / 13.3 (P.No. 92, I.No. 13.36 of PWD SR 2015-16)
13.37 KSRB13-6.3-6 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 50mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 2052.00
13.2.6 / 13.3. (P.No.92/ I.No. 13.37 of CSR 2015-16)
13.38 KSRB13-6.3-7 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 65mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 2575.00
13.2.6 / 13.3. (P.No.92/ I.No. 13.38 of CSR 2015-16)
13.39 KSRB13-6.3-8 : Providing and fixing in position brass gate valve with C.I wheel of
approved quality ( screwed end ) 80mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 3059.00
13.2.6 / 13.3
13.40 KSRB13-6.4-1 : Providing and fixing in position brass ball valve high or low pressure with
plastic float of approved quality 15mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 391.00

13.41 KSRB13-6.4-2 : Providing and fixing in position brass ball valve high or low pressure with
plastic float of approved quality 20mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 410.00

13.42 KSRB13-6.4-3 : Providing and fixing in position brass ball valve high or low pressure with
plastic float of approved quality 25mm nominal bore including cost of all materials, labour
and HOM of equipments with all leads complete as per specifications. Specification No.KBS Each 606.00

13.43 KSRB13-6.5-1 : Providing and fixing in position 15mm nominal bore brass ferrule with C.I
mouth cover including boring and tapping the main, cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification No.KBS 13.2.3 / Each 182.00
13.14
13.44 KSRB13-6.5-2 : Providing and fixing in position 20mm nominal bore brass ferrule with C.I
mouth cover including boring and tapping the main, cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification No.KBS 13.2.3 / Each 235.00
13.14
13.45 KSRB13-6.5-3 : Providing and fixing in position 25mm nominal bore brass ferrule with C.I
mouth cover including boring and tapping the main, cost of all materials, labour and HOM
of equipments with all leads complete as per specifications. Specification No.KBS 13.2.3 / Each 270.00
13.14

Page 71 of 350
13.46 KSRB13-6.6-1 : Providing and fixing unplasticised PVC connection pipe with brass union
15mm nominal bore 300 mm length of PVC connection including cost of all materials,
labour and HOM of equipments with all leads complete as per specifications. Specification Set 263.00
No.KBS
13.47 KSRB13-6.6-2 : Providing and fixing unplasticised PVC connection pipe with brass union
15mm nominal bore 450mm length of PVC connection including cost of all materials,
labour and HOM of equipments with all leads complete as per specifications. Specification Set 328.00
No.KBS. (P.No.92, I.No. 13.47 of PWD SR 2015-16)
13.48 KSRB13-6.6-3 : Providing and fixing unplasticised PVC connection pipe with brass union
20mm nominal bore 300 mm length of PVC connection including cost of all materials,
labour and HOM of equipments with all leads complete as per specifications. Specification Set 272.00
No.KBS
13.49 KSRB13-6.6-4 : Providing and fixing unplasticised PVC connection pipe with brass union
20mm nominal bore 450mm length of PVC connection including cost of all materials,
labour and HOM of equipments with all leads complete as per specifications. Specification Set 305.00
No.KBS
13.50 KSRB13-6.7-1 : Providing and fixing in position chromium plated brass shower rose with
15 or 20mm inlet 100mm dia including cost of all materials, labour and HOM of equipments
with all leads complete as per specifications. Specification No.KBS 13.2.16 / 13.3 Each 795.00

13.51 KSRB13-6.7-2 : Providing and fixing in position chromium plated brass shower rose with
15 or 20mm inlet 150mm dia including cost of all materials, labour and HOM of equipments
with all leads complete as per specifications. Specification No.KBS 13.2.16 / 13.3 Each 851.00

13.52 KSRB13-7.1-1 : Providing and fixing in position 25mm nominal bore gun metal non-return
valve horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 693.00
13.13

Page No. 92
13.53 KSRB13-7.1-2 : Providing and fixing in position 32mm nominal bore gun metal non-return
valve horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 836.00
13.13
13.54 KSRB13-7.1-3 : Providing and fixing in position 40mm nominal bore gun metal non-return
valve horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Each 1081.00
13.13
13.55 KSRB13-7.1-4 : Providing and fixing in position 50mm nominal bore gun metal non-return
valve horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 1496.00
13.13
13.56 KSRB13-7.1-5 : Providing and fixing in position 65mm nominal bore gun metal non-return
valve horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 2070.00
13.13
13.57 KSRB13-7.1-6 : Providing and fixing in position 80mm nominal bore gun metal non-return
valve horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 2418.00
13.13
13.58 KSRB13-7.1-7 : Providing and fixing in position 100mm nominal bore gun metal non-return
valve horizontal type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 2836.00
13.13
13.59 KSRB13-7.2-1 : Providing and fixing in position 25mm nominal bore non-return valve
vertical type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 534.00
13.13

Page 72 of 350
13.60 KSRB13-7.2-2 : Providing and fixing in position 32mm nominal bore non-return valve
vertical type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 844.00
13.13
13.61 KSRB13-7.2-3 : Providing and fixing in position 40mm nominal bore non-return valve
vertical type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 1016.00
13.13
13.62 KSRB13-7.2-4 : Providing and fixing in position 50mm nominal bore non-return valve
vertical type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 1435.00
13.13
13.63 KSRB13-7.2-5 : Providing and fixing in position 65mm nominal bore non-return valve
vertical type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 1801.00
13.13
13.64 KSRB13-7.2-6 : Providing and fixing in position 80mm nominal bore non-return valve
vertical type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 2177.00
13.13
13.65 KSRB13-7.2-7 : Providing and fixing in position 100mm nominal bore non-return valve
vertical type of approved make including cost of all materials, labour and HOM of
equipments with all leads complete as per specifications. Specification No.KBS 13.2.10 / Nos 2902.00
13.13
13.66 KSRB13-8.1 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 20mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor including cost m 92.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.67 KSRB13-8.2 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 25mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 117.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.68 KSRB13-8.3 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 32mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 185.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.69 KSRB13-8.4 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 40mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 225.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.70.1 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 50mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 263.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.70.2 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 63mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 273.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.70.3 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 75mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 302.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9

Page 73 of 350
13.70.4 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 90mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 356.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.70.5 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 110mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 426.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.70.6 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 140mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 532.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
13.70.7 KSRB13-8.5 : Providing and fixing to wall, ceiling and floor, low density polyethylene
pipes 6.00 kgf/sq.cm working pressure 160mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 603.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.1 / 13.9
Page No. 93
13.71 KSRB13-9.1 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 32mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 238.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.2 / 13.9
13.72 KSRB13-9.2 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 40mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 263.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.2 / 13.9
13.73.1 KSRB13-9.3 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 50mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 346.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.2 / 13.9
13.73.2 KSRB13-9.4 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 63mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 348.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.2 / 13.9
13.73.3 KSRB13-9.5 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 75mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost
of all materials, labour charges, HOM of equipments and testing complete as per m 401.00
specifications. Specification No.KBS 13.2.15.2 / 13.9. (P.No. 94/ I.No. 13.73.3 of CSR
2015-16)

13.73.4 KSRB13-9.6 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 90mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost
of all materials, labour charges, HOM of equipments and testing complete as per m 474.00
specifications. Specification No.KBS 13.2.15.2 / 13.9. (P.No. 94, I.No.13.73.4 of PWD SR
2015-16)

13.73.5 KSRB13-9.7 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 110mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost m 571.00
of all materials, labour charges, HOM of equipments and testing complete as per
specifications. Specification No.KBS 13.2.15.2 / 13.9

Page 74 of 350
13.73.6 KSRB13-9.8 : Providing and fixing to wall, ceiling and floor high density polyethylene
pipes 6.00 kgf/sq.cm working pressure 140mm outside diameter with special flange,
compression type fittings, wall clips, making good the wall, ceiling and floor, including cost
of all materials, labour charges, HOM of equipments and testing complete as per m 717.00
specifications. Specification No.KBS 13.2.15.2 / 13.9. (P.No. 94, I.No.13.73.5 of PWD SR
2015-16)

13.74 KSRB13-10.1 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes
10.00 kgf/sq.cm working pressure 16mm outside diameter chemp plast / Wavin or
equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, m 94.00
including cost of all materials, labour charges, HOM of equipments and testing complete as
per specifications. Specification No.KBS 13.2.15.4 / 13.9
13.75 KSRB13-10.2 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes
10.00 kgf/sq.cm working pressure 20mm outside diameter chemp plast / Wavin or
equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, m 96.00
including cost of all materials, labour charges, HOM of equipments and testing complete as
per specifications. Specification No.KBS 13.2.15.4 / 13.9
13.76 KSRB13-10.3 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes
10.00 kgf/sq.cm working pressure 25mm outside diameter chemp plast / Wavin or
equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, m 109.00
including cost of all materials, labour charges, HOM of equipments and testing complete as
per specifications. Specification No.KBS 13.2.15.4 / 13.9
13.77 KSRB13-10.4 : Providing and fixing to wall, ceiling and floor unplasticised PVC pipes
10.00 kgf/sq.cm working pressure 32mm outside diameter chemp plast / Wavin or
equivalent make with pipe fittings, wall clips, making good the wall, ceiling and floor, m 121.00
including cost of all materials, labour charges, HOM of equipments and testing complete as
per specifications. Specification No.KBS 13.2.15.4 / 13.9
13.78 KSRB 13-11.1 : Providing and placing on terrace, polyethylene water storage tanks with
manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet,
outlet and over flow pipes, including cost of all materials, labour, transport charges, HOM of Nos 8467.00
equipments and testing complete as per specifications.(For 1000 litre capacity) Specification
No.KBS 13.22
13.79.1 Providing and fixing gun metal wheel valve conforming to IS specification of approved
make as per directions including all lead and lift etc., complete. - for 15mm dia: Each 295.00

13.79.2 Providing and fixing gun metal wheel valve conforming to IS specification of approved
make as per directions including all lead and lift etc., complete.- for 20mm dia: Each 365.00

13.79.3 Providing and fixing gun metal wheel valve conforming to IS specification of approved
make as per directions including all lead and lift etc., complete.- for 25mm dia: Each 505.00

13.79.4 Providing and fixing gun metal wheel valve conforming to IS specification of approved
make as per directions including all lead and lift etc., complete.- for 32mm dia: Each 740.00

13.79.5 Providing and fixing gun metal wheel valve conforming to IS specification of approved
make as per directions including all lead and lift etc., complete.- for 40mm dia: Each 940.00

13.79.6 Providing and fixing gun metal wheel valve conforming to IS specification of approved
make as per directions including all lead and lift etc., complete.- for 50mm dia: Each 1440.00

Page No. 94
13.80 Providing gun metal pillar cocks 15mm dia of I class conforming to ISI specifications and
fixing them in position as per directions including of cost of materials and fixtures and Each 250.00
conveyance to spot.
13.81.1 Providing NP/CP waste unions conforming to ISI specifications and fixing them in position
as per directions including cost of materials, fixtures and conveyance to work spot etc., Each 125.00
complete. - for 32mm dia

Page 75 of 350
13.81.2 Providing NP/CP waste unions conforming to ISI specifications and fixing them in position
as per directions including cost of materials, fixtures and conveyance to work spot etc., Each 155.00
complete.- for 40mm dia:
13.81.3 Providing NP/CP waste unions conforming to ISI specifications and fixing them in position
as per directions including cost of materials, fixtures and conveyance to work spot etc., Each 215.00
complete.- for 50mm dia:
13.82.1 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure
Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g. m 180.00
elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing,
cutting & making good the walls etc., including testing complete as required. (Internal work)
Pipes exposed on wall - 1216(16 mm OD) Pipe

13.82.2 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g. m 220.00
elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing,
cutting & making good the walls etc., including testing complete as required. (Internal work)
Pipes exposed on wall - 1620(20mm OD) pipe

13.82.3 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g. m 285.00
elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing,
cutting & making good the walls etc., including testing complete as required. (Internal work)
Pipes exposed on wall - 2025(25mm OD) pipe

13.82.4 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g. m 400.00
elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing,
cutting & making good the walls etc., including testing complete as required. (Internal work)
Pipes exposed on wall - 2532(32mm OD) pipe

13.82.5 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g. m 505.00
elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing,
cutting & making good the walls etc., including testing complete as required. (Internal work)
Pipes exposed on wall - 3240 (40mm OD) pipe

13.82.6 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g. m 610.00
elbows, tees, reducers, couplers & connectors etc., with clamps at 1.00 meter spacing,
cutting & making good the walls etc., including testing complete as required. (Internal work)
Pipes exposed on wall - 4050 (50mm OD) pipe

13.83.1 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with cement tacking at 1.00 meter m 250.00
spacing, and every fitting, cutting & making good the walls etc., including testing complete
as required. (Internal work) Concealed piping with cutting chases & making good walls etc.,
- 1216(16 mm OD) Pipe

Page 76 of 350
13.83.2 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure
Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with cement tacking at 1.00 meter m 290.00
spacing, and every fitting, cutting & making good the walls etc., including testing complete
as required. (Internal work) Concealed piping with cutting chases & making good walls etc.,
- 1620(20mm OD) pipe

13.83.3 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with cement tacking at 1.00 meter m 350.00
spacing, and every fitting, cutting & making good the walls etc., including testing complete
as required. (Internal work) Concealed piping with cutting chases & making good walls etc.,
- 2025(25mm OD) pipe

13.83.4 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with cement tacking at 1.00 meter m 445.00
spacing, and every fitting, cutting & making good the walls etc., including testing complete
as required. (Internal work) Concealed piping with cutting chases & making good walls etc.,
- 2532(32mm OD) pipe

Page No. 95
13.83.5 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure
Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with cement tacking at 1.00 meter m 580.00
spacing, and every fitting, cutting & making good the walls etc., including testing complete
as required. (Internal work) Concealed piping with cutting chases & making good walls etc.,
- 3240 (40mm OD) pipe

13.83.6 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL-PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with cement tacking at 1.00 meter m 750.00
spacing, and every fitting, cutting & making good the walls etc., including testing complete
as required. (Internal work) Concealed piping with cutting chases & making good walls etc.,
- 4050 (50mm OD) pipe

13.84.1 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with tranching & refilling upto 1.00 meter m 170.00
depth including testing complete as required. (External work) Pipe in trenches including
excavation & refilling etc.,
- 1216 (16mm OD) pipe

13.84.2 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with tranching & refilling upto 1.00 meter m 225.00
depth including testing complete as required. (External work) Pipe in trenches including
excavation & refilling etc., - 1620(20mm OD) pipe

Page 77 of 350
13.84.3 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE) Composite Pressure
Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with tranching & refilling upto 1.00 meter m 280.00
depth including testing complete as required. (External work) Pipe in trenches including
excavation & refilling etc., - 2025 (25mm OD) pipe

13.84.4 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with tranching & refilling upto 1.00 meter m 360.00
depth including testing complete as required. (External work) Pipe in trenches including
excavation & refilling etc., - 2532 (32mm OD) pipe

13.84.5 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with tranching & refilling upto 1.00 meter m 460.00
depth including testing complete as required. (External work) Pipe in trenches including
excavation & refilling etc., - 3240 (40mm OD) pipe

13.84.6 Providing & fixing Polyethelene-Aluminium-Polyethelene (PE-AL- PE) Composite Pressure


Pipes conforming to IS 15450 duly “ISI” marked, U.V. stabalized with Carbon black for hot
& cold water supply, capable to withstand temperature upto 80°C including all special
composite fittings (engineering plastic blend and brass inserts wherever required.) e.g.
elbows, tees, reducers, couplers & connectors etc. with tranching & refilling upto 1.00 meter m 555.00
depth including testing complete as required. (External work) Pipe in trenches including
excavation & refilling etc., - 4050 (50mm OD) pipe

13.85.1 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This m 115.00
includes jointing of pipes and fittings with one step CPVC solvent cement and testing of
joints complete. (internal work exposed on wall) - 15mm nominal OD pipes
13.85.2 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This m 135.00
includes jointing of pipes and fittings with one step CPVC solvent cement and testing of
joints complete. (internal work exposed on wall) - 20mm nominal OD pipes
13.85.3 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This
includes jointing of pipes and fittings with one step CPVC solvent cement and testing of m 170.00
joints complete. (internal work exposed on wall) - 25mm nominal OD pipes. (P.No. 96/I.No.
13.85.3 of CSR 2015-16)

13.85.4 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This m 225.00
includes jointing of pipes and fittings with one step CPVC solvent cement and testing of
joints complete. (internal work exposed on wall) - 32mm nominal OD pipes
13.85.5 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This m 310.00
includes jointing of pipes and fittings with one step CPVC solvent cement and testing of
joints complete. (internal work exposed on wall) - 40mm nominal OD pipes

Page 78 of 350
13.85.6 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This
includes jointing of pipes and fittings with one step CPVC solvent cement and testing of m 440.00
joints complete. (internal work exposed on wall) - 50mm nominal OD pipes. (P.No. 96/I.No.
13.85.6 of CSR 2015-16)

13.86.1 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This
includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of m 130.00
cutting chases & making good the same including testing of joints complete. (Concealed
work including cutting chases and good the walls etc.) - 15mm nominal OD pipes

13.86.2 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This
includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of
cutting chases & making good the same including testing of joints complete. (Concealed m 210.00
work including cutting chases and good the walls etc.) - 20mm nominal OD pipes. (P.No.96,
I.No. 13.86.2 of PWD SR 2015-16)

13.86.3 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This
includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of m 250.00
cutting chases & making good the same including testing of joints complete. (Concealed
work including cutting chases and good the walls etc.) - 25mm nominal OD pipes

13.86.4 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS
15778, having thermal stability for hot and cold water supply including all CPVC plain and
brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This
includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of m 310.00
cutting chases & making good the same including testing of joints complete. (Concealed
work including cutting chases and good the walls etc.) - 32mm nominal OD pipes

Page No. 96
13.87.1 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 110.00
trenching, refilling & testing of joints complete. (external work). - 15mm nominal OD pipes

13.87.2 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 125.00
trenching, refilling & testing of joints complete. (external work). - 20mm nominal OD pipes

13.87.3 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 165.00
trenching, refilling & testing of joints complete. (external work). - 25mm nominal OD pipes

13.87.4 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 215.00
trenching, refilling & testing of joints complete. (external work). - 32mm nominal OD pipes

Page 79 of 350
13.87.5 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 300.00
trenching, refilling & testing of joints complete. (external work). - 40mm nominal OD pipes

13.87.6 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 450.00
trenching, refilling & testing of joints complete. (external work). - 50mm nominal OD pipes

13.87.7 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 1390.00
trenching, refilling & testing of joints complete. (external work). - 62.50mm nominal OD
pipes
13.87.8 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 1715.00
trenching, refilling & testing of joints complete. (external work). - 75mm nominal OD pipes.
(P.No. 97/ I.No. 13.87.8 of CSR 2015-16)
13.87.9 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 2380.00
trenching, refilling & testing of joints complete. (external work). - 100mm nominal OD
pipes
13.87.1 Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778
0 having thermal stability for hot and cold water supply including all CPVC plain and brass
threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, m 4140.00
trenching, refilling & testing of joints complete. (external work). - 150mm nominal OD
pipes
13.88 Providing and fixing polished granite sink of size 60cms x 90cms of 23cm thick, the sink
portion shall be 15cm in depth of shapes oval / round / square over brick masonry in cement
mortar 1:6 including cost and conveyance of all materials, labour for all items of work,
HOM of equipment with all lead and lift, loading and unloading, transportation charges and Each 7070.00
all other incidental charges etc., complete as per specification and directions of the Engineer-
in-charge of the work.

13.89 Providing and fixing polished granite sink of size 60cms x 75cms of 23cm thick, the sink
portion shall be 15cm in depth of shapes oval / round / square over brick masonry in cement
mortar 1:6 including cost and conveyance of all materials, labour for all items of work,
HOM of equipment with all lead and lift, loading and unloading, transportation charges and Each 5957.00
all other incidental charges etc., complete as per specification and directions of the Engineer-
in-charge of the work.

13.90 Providing and fixing polished granite sink of size 60cms x 60cms of 23cm thick, the sink
portion shall be 15cm in depth of shapes oval / round / square over brick masonry in cement
mortar 1:6 including cost and conveyance of all materials, labour for all items of work,
HOM of equipment with all lead and lift, loading and unloading, transportation charges and Each 4844.00
all other incidental charges etc., complete as per specification and directions of the Engineer-
in-charge of the work.

13.91 Providing and Fixing Stainless Steel sink of sizes upto 60cms x 45cms in 20mm thick
granite slab of by cutting required thickness and width of grooves and fixing using adhesives
etc., complete including cost and conveyance of all materials, labour for all items of work,
HOM of equipment with all lead and lift, loading and unloading, transportation charges and Each 5793.00
all other incidental charges etc., complete as per specification and directions of the Engineer-
in-charge of the work.

Page No. 97
13.92.1 Cutting granite slab upto 40mm thick and required width of grooves for fixing Stainless
No 636.00
steel sink upto 60cm x 45 cms and fixing using adhesives.
13.92.2 Cutting granite slab upto 40mm thick and required width of grooves for fixing Stainless steel
No 956.00
sink above 60cm x 45 cms and fixing using adhesives.

Page 80 of 350
13.93.1 Providing and fixing concealed UVstabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings incluiding brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for concealed m 200.00
fitting - 20mm pipe outer dia (3 layer)
13.93.2 Providing and fixing concealed UVstabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings incluiding brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for concealed m 265.00
fitting - 25mm pipe outer dia (3 layer)
13.93.3 Providing and fixing concealed UVstabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings incluiding brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for concealed m 320.00
fitting - 32mm pipe outer dia (3 layer)
13.94.1 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 compete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for m 135.00
exposed on wall - 20mm pipe outer dia (3 layer)
13.94.2 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 compete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for m 175.00
exposed on wall - 25mm pipe outer dia (3 layer)
13.94.3 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 compete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for m 230.00
exposed on wall - 32mm pipe outer dia (3 layer)
13.94.4 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 compete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for m 330.00
exposed on wall - 40mm pipe outer dia (3 layer)
13.94.5 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 compete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. Internal Plumbing - for m 490.00
exposed on wall - 50mm pipe outer dia (3 layer)
13.95.1 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 125.00
20mm pipe outer dia (3 layer)
13.95.2 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing -25mm m 175.00
pipe outer dia (3 layer)
13.95.3 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 215.00
32mm pipe outer dia (3 layer)
13.95.4 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 300.00
40mm pipe outer dia (3 layer)
13.95.5 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 530.00
50mm pipe outer dia (3 layer)
13.95.6 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 665.00
63mm pipe outer dia (3 layer)

Page 81 of 350
13.95.7 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 835.00
75mm pipe outer dia (3 layer)
13.95.8 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 1270.00
90mm pipe outer dia (3 layer)
13.95.9 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 1340.00
110mm pipe outer dia (3 layer)
13.95.1 Providing and fixing concealed UV stabilised and antimicrobial fusion 3 layer PP-R pipes
0 confirming to DIN 8077 complete with PP-R plain fittings including brass threaded
polypropelene random fittings including chasing the walls. External plumbing - m 2470.00
160mm pipe outer dia (3 layer)
Page No. 98

14.0 14.FLOORING

14.1 KSRB 14.1 : Providing and laying flooring with burnt stone slabs 10 cms thick, rough
chistle dressed on sand bed 7.5 cms to 8 cms thick and pointed with cement mortar 1:3, ,
including cost of materials, labour, curing complete as per specifications. Specification No. Sqm 1040.00
KBS 14.26
14.2 KSRB 14.2 : Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle
dressed on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3, ,
including cost of materials, labour, curing complete as per specifications. Specification No. Sqm 1013.00
KBS 14.26
14.3 KSRB 14.3 : Providing and laying flooring and steps machine cut granite slabs 40mm thick
on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over existing
cement concrete bed , including cost of materials, labour, curing complete as per Sqm 2665.00
specifications. Specification No. KBS 14.26

14.4 KSRB 14.4 : Providing and laying flooring and steps fine dressed granite stone slabs 40 mm
thick on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3 over
existing cement concrete bed , including cost of materials, labour, curing complete as per Sqm 3161.00
specifications. Specification No. KBS 14.26
14.5 KSRB 14.5 : Providing and laying flooring and steps fine machine polished granite stone
slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement
mortar 1:3 over existing cement concrete bed , including cost of materials, labour, curing Sqm 1159.00
complete as per specifications. Specification No. KBS 14.26
14.6 KSRB 14.6-1: Providing and laying heavy duty cobble stones 60mm thick interlock
pavers, using cement and course sand for manufacture of blocks of approved size, shape and
colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed
(average thickness ) and compacting with plate vibrator having 3 tons compaction force
thereby forcing part of sand underneath to come up in between joints, final compaction of Sqm 912.00
paver surface joints into its final level, including cost of materials, labour and HOM of
machineries complete as per specifications. Specification No. KBS. (P.No. 101, I.No. 14.6 of
CSR 2015-16)

14.7 KSRB 14.6-2 :Providing and laying heavy duty cobble stones 75mm thick interlock
pavers, using cement and course sand for manufacture of blocks of approved size, shape and
colour with a minimum compressive strength of 281 kg per sqm over 50mm thick sand bed
(average thickness ) and compacting with plate vibrator having 3 tons compaction force
thereby forcing part of sand underneath to come up in between joints, final compaction of Sqm 970.00
paver surface joints into its final level, including cost of materials, labour and HOM of
machineries complete as per specifications. Specification No. KBS (P.No. 101, I.No. 14.7 of
CSR 2015-16)

Page 82 of 350
14.8 KSRB 14.7-1: Providing and laying flooring with M15 cement concrete 40 mm thick using
broken granite 20mm and down size laid to line and level in one layer and finish with a
floating coat of neat cement , including cost of materials, labour, curing, complete as per Sqm 323.00
specifications. Specification No. KBS 14.3
Page No. 101
14.9 KSRB 14.7-2 : Providing and laying red oxide flooring 40 mm thick, with an under layer of
30mm thick M-15 cement concrete, using broken granite metal of 12.5mm nominal size and
top layer of 10mm thick plaster with 1:3 cement mortar mixed with red oxide ( using 3.5 kg
of red oxide per 50 kg of cement ) finished with floating coat of neat cement mixed with red Sqm 578.00
oxide ( mix of same proportion ) , including cost of materials, labour, curing, complete as
per specifications. Specification No. KBS 14.3

14.10 KSRB 14.7-3 : Providing and laying flooring 40 mm thick, with an under layer of 30mm
thick M-15 cement concrete, using broken granite metal of 12.5mm nominal size and top
layer of 10mm thick plaster with cement mortar 1:3, finished with floating coat of neat Sqm 517.00
cement , including cost of materials, labour, curing, complete as per specifications.
Specification No. KBS 14.3. (P.No. 102, I.No. 14.10 of CSR 2015-16)
14.11 KSRB 14.7-4 : Extra for making chequers of approved pattern on cement concrete floor,
steps, landings, pavements , including cost of labour complete as per specifications. Sqm 22.00
Specification No. KBS
14.12 KSRB 14.8-1: Providing and laying linolium covering to floors plain or coloured 3.2mm
thick sheet / tiles laid with an approved adhesive on sub floor stretching, cutting and fixing
complete , including cost of materials, labour, complete as per specifications. Specification Sqm 413.00
No. KBS 14.37.7
14.13 KSRB 14.9-1: Providing and laying M-15 cement concrete flooring, 50 mm thick with
metallic concrete hardner toping, under layer of 35mm thick m-15 cement concrete using
broken granite metal of 20mm and down size, and top layer 50mm thick of metallic cement
hardner consisting of mix 1:2 ( 1 cement hardner mix : 2 granite metal 10mm nominal size )
by volume, with which metallic hardening compound of approved quality mix in the ratio of Sqm 591.00
4:1 ( 4 part of cement and 1 part of metallic floor hardening compound of approved quality
by wt) , including finishing cost of materials, labour, curing, complete as per specifications
Specification No. KBS 14.4

14.14 KSRB 14.9-2 : Providing and laying M-15 cement concrete flooring 60 mm thick with
metallic concrete hardner toping, under layer of 45mm thick M-15 cement concrete using
broken granite metal of 20mm and down size and top layer of 15mm thick metallic cement
hardner consisting of mix 1:2 ( 1 cement hardner mix : 2 granite metal 10mm nominal size )
by volume, with metalic hardening compound of approved quality mix in the ratio of 4:1 ( 4 Sqm 673.00
part of cement = 1 part of metallic floor hardening compound of approved quality by wt ) ,
including finishing, cost of materials, labour, curing, complete as per specifications.
Specification No. KBS 14.4

Page No. 102


14.15 KSRB 14.10-1: Flooring with 25mm to 40mm thick polished tandur blue stone slabs using
cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line
and level and jointed with cement slurry mixed with pigment to match the shade of the Sqm 1121.00
slab, , including cost of materials, labour, curing, polishing complete as per specifications.
Specification No. KBS
14.16 KSRB 14.10-2: Flooring with 25mm to 40mm thick polished shahabad slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and
level and jointed with cement slurry mixed with pigment to match the shade of the slab, , Sqm 1199.00
including cost of materials, labour, curing, polishing complete as per specifications.
Specification No. KBS
14.17 KSRB 14.10-3: Providing flooring with 25mm to 40mm thick polished Cadapa slabs using
cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line
and level and jointed with cement slurry mixed with pigment to match the shade of the slab, Sqm 1106.00
including cost of materials, labour, curing, polishing complete as per specifications.
Specification No. KBS

Page 83 of 350
14.18 KSRB 14.11-1: Providing mosaic flooring with cast-in-situ 40mm thick using marble chips
flooring rubbed and polished to granolithic finish with under layer of 28mm thick cement
concrete M-15 with stone aggregate 12mm and down size, and top layer 12mm thick with
dark shade pigment with ordinary cement in top layer only using white, black, chacolate,
yellow or baroda green marble chips of size from 7 to 10 nominal size laid in cement marble
Sqm 1220.00
powder mix 3:1 ( 3 cement : 1 marble powder by weight ) in proportion of 4:7 ( 4 cement
marble powder mix : 7 marble chips by volume ) curing polishing oxalic acid wash, wax
polish , including cost of materials, labour, complete as per specifications. Specification No.
KBS 14.8

14.19 KSRB 14.11-2 : Providing mosaic flooring with cast-in-situ 40mm thick using marble chips
flooring, rubbed and polished to granolithic finish with under layer of 28mm thick cement
cocrete M-15 with stone aggregate 12mm and down size , and top layer 12mm thick with
light shade pigment with white cement in top layer only using white, black, chacolate,
yellow or baroda green marble chips of size from 7 to 10 nominal size laid in cement marble
Sqm 1338.00
stone mixed 3:1 ( 3 cement : 1 marble powder by weight ) in proportion of 4:7 ( 4 cement
marble powder mix : 7 marble chips by volume ) curing polishing oxalic acid wash, wax
polish , including cost of materials, labour, complete as per specifications. Specification No.
KBS 14.8

14.20 KSRB 14.11-3 : Providing mosaic flooring with cast-in-situ 40mm thick using marble chips
flooring rubbed and polished to granolithic finish with under layer of 28mm thick cement
cocrete M-15 with stone aggregate 12mm and down size, and top layer 12mm thick with
medium shade pigment with approximately 50% white cement and 50% ordinary cement in
top layer only using white, black, chacolate, yellow or baroda green marble chips of size
from 7 to 10 nominal size laid in cement marble stone mixed 3:1 ( 3 cement : 1 marble Sqm 1247.00
powder by weight ) in proportion of 4:7 ( 4 cement marble powder mix : 7 marble chips by
volume ) curing polishing oxalic acid wash, wax polishing, including cost of materials,
labour, complete as per specifications. Specification No. KBS 14.8

Page No. 103


14.21 KSRB 14.11-4 : Providing mosaic flooring with cast-in-situ 40mm thick using marble chips
and polished to granolithic finish with under layer of 28mm thick cement concrete M-15
with stone aggregate 12mm and down size , and top layer 12mm thick with white cement
without any pigment in top layer only using white, black, chacolate, yellow or baroda green
marble chips of size from 7 to 10 nominal size laid in cement marble powder mix 3:1 ( 3
Sqm 1256.00
cement : 1 marble powder by weight ) in proportion of 4:7 ( 4 cement marble powder mix : 7
marble chips by volume ) curing, polishing oxalic acid wash, wax polish , including cost of
materials, labour, complete as per specifications. Specification No. KBS 14.8

14.22 KSRB 14.11-5 :Extra for providing and fixing aluminium strips 40 mm wide and 1.5mm
thick painted with a protective coat of bitumen for joints of mosaic floors, including cost of
materials, labour, curing, complete as per specifications. Specification No. KBS m 33.00

14.23 KSRB 14.11-6 :Extra for providing and fixing glass strips 40 mm wide and 4mm thick for
joints of mosaic floors , including cost of materials, labour, curing, complete as per m 43.00
specifications. Specification No. KBS
14.24 KSRB 14.12-1: Providing mosaic tiles flooring with precast grey colour mosaic tiles 20mm
thick using marble chips of approved colour 7 to 10 nominal size laid in floors and landings
on a bed of 25mm thick cement mortar 1:6, mix, jointed with neat cement slurry mix with
pigment to match the shade of tiles curing, rubbing, polishing, oxalic acid wash, wax polish , Sqm 732.00
including cost of materials, labour, HOM of machinary complete as per specifications.
Specification No. KBS 14.11

14.25 KSRB 14.12-2: Providing mosaic tiles flooring with precast light shade pigment with white
cement mosaic tiles 20mm thick using marble chips of approved colour 7 to 10 nominal size
laid in floors and landings on a bed of 25mm thick cement mortar 1:6, mix, jointed with neat
cement slurry mix with pigment to match the shade of tiles, curing. rubbing, polishing, Sqm 818.00
oxalic acid wash, wax polish, including cost of materials, labour, HOM of machinary
complete as per specifications. Specification No. KBS 14.11

Page 84 of 350
14.26 KSRB 14.12-3 : Providing mosaic tiles flooring with precast medium shade pigment using
50% white cement and 50% ordinary cement mosaic tiles 20mm thick using marble chips of
approved colour 7 to 10 nominal size laid in floors and landings on a bed of 25mm thick
average thickness of cement mortar 1:6, mix, jointed with neat cement slurry mix with Sqm 646.00
pigment to match the shade of tiles, curing, rubbing, polishing, oxalic acid wash, wax
polish , including cost of materials, labour, HOM of machinary complete as per
specifications.

Page No. 104


14.27 KSRB 14.12-4 : Providing mosaic tiles flooring with white precast cement mosaic tiles
20mm thick using marble chips of 7 to 10 nominal size laid in floors and landings on a bed
of 25mm thick average thickness of cement mortar 1:6, mix, jointed with neat cement slurry
mix with pigment to match the shade of tiles, curing, rubbing, polishing, oxalic acid wash, Sqm 774.00
wax polish , including cost of materials, labour, HOM of machinary complete as per
specifications.

14.28 KSRB 14.13-1: Providing precast chequered mosaic tiles dark shade using ordinary grey
cement for steps and flooring, with precast 20mm thick, using marble chips of 7 to 10
nominal size laid in floors, steps and landings on a bed of 12mm thick cement mortar 1:3
mix, and jointed with neat cement slurry mixed with pigment to match the shade of tiles, Sqm 972.00
curing, rubbing, polishing, oxalic acid wash, wax polish , including cost of materials, labour,
complete as per specifications.

14.29 KSRB 14.13-2: Providing precast chequered mosaic tiles light shade using white cement for
steps and flooring, 20mm thick, using marble chips of 7 to 10 nominal size laid in floors,
steps and landings on a bed of 12mm thick cement mortar 1:3 mix, and jointed with neat
cement slurry mixed with pigment to match the shade of tiles curing, rubbing, polishing, Sqm 1080.00
oxalic acid wash, wax polish , including cost of materials, labour, complete as per
specifications. Specification No. KBS 14.13, 14.14

14.30 KSRB 14.13-3: Providing precast chequered mosaic tiles medium shade pigment using 50%
white cement and 50% ordinary cement for steps and flooring 20mm thick using marble
chips of 7 to 10 nominal size laid on a bed of 12mm thick cement mortar 1:3 mix, and
jointed with neat cement slurry mixed with pigment to match the shade of tiles curing, Sqm 1039.00
rubbing, polishing, oxalic acid wash, wax polish , including cost of materials, labour,
complete as per specifications. Specification No. KBS 14.13, 14.14

14.31 KSRB 14.13-4: Providing precast chequered mosaic tiles white colour for steps and flooring,
20mm thick, using marble chips of 7 to 10 nominal size laid on a bed of 12mm thick cement
mortar 1:3 mix, and jointed with neat cement slurry mixed with pigment to match the shade
of tiles rubbing, polishing, oxalic acid wash, wax polish, including cost of materials, labour, Sqm 1138.00
curing, complete as per specifications. Specification No. KBS 14.13, 14.14

Page No. 105


14.36.1 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads
of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing
with white cement using colour pigment , including cost of materials, labour, curing, Sqm 925.00
complete as per specifications. - for Ceramic Tiles of size 15x15cms 6mm thick
14.36.2 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads
of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing
with white cement using colour pigment , including cost of materials, labour, curing, Sqm 1176.00
complete as per specifications. - for Ceramic Tiles of size 30x30cms 6mm thick. (P.No.106,
I.No. 14.36.2 of PWD SR 2015-16)
14.36.3 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads
of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing
with white cement using colour pigment , including cost of materials, labour, curing, Sqm 1178.00
complete as per specifications. - for Ceramic Tiles 400 x 400mm on a bed of 20mm thick

14.36.4 KSRB 14.14-5: Providing Ceramic tiles of approved make,shade and size for flooring, treads
of steps and landings laid on a bed of 12mm thick, cement mortar 1:3 mix, flush pointing
with white cement using colour pigment , including cost of materials, labour, curing, Sqm 1178.00
complete as per specifications. - for Ceramic tiles 30cm x 60cm 6mm thick on a bed of
20mm thick

Page 85 of 350
14.37 KSRB 14.15-1: Providing marble slab flooring 20mm thick with edges of slab machine cut,
for flooring, treads of steps and landings laid on a bed of 25mm thick cement mortar 1:6,
mix, to line and level, jointed with cement slurry curing, rubbing, polishing complete
finishIing with flush pointing using white cement, including cost of materials, HOM of
machineries, labour, curing, complete as per specifications. Note : While preparing analysis Sqm 3111.00
the quality of marble slab should be clearly noted namely white marble, adanga marble,
makrana etc., and also size of slab should be noted clearly. Specification No. KBS 14.18

14.38 KSRB 14-16.1 : Providing skirting upto 30 cms. height with cement mortar 1:3 finished with
a floating coat of neat cement including rounding off junctions floor, overall 15 mm thick
including cost of materials, labour, complete as per specifications. Specification No.KBS Sqm 271.00
14.5
14.39 KSRB 14-16.2 : Providing red oxide skirting upto 30 cms. height with cement mortar 1:3
including rounding off junctions with floor, finished overall 15 mm thick, top portion 5mm
thick mixed with red oxide and a floating coat of neat cement using 3.5kg of red oxide of Sqm 295.00
iron per 50 kg of cement including cost of materials, labour, complete as per specifications.
Specification No.KBS 14.5
14.40 KSRB 14-17.1 : Providing skirting, dado, rises of steps with white glazed tiles 6mm thick on
10mm thick cement plaster 1:3 and jointed with white cement slurry over rough plaster
surface ( excluding cost of rough plastered surface which should be measured and paid
separately) using glazed tiles of approved make and size including cost of materials, labour, Sqm 951.00
complete as per specifications. Specification No.KBS 14.16, 14.17

14.41.1 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm
thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface
( excluding cost of rough plastered surface which should be measured and paid separately)
using glazed tiles of approved make and size including cost of materials, labour, complete as Sqm 1072.00
per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 15x15 cms 6mm
thick

14.41.2 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm
thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface
( excluding cost of rough plastered surface which should be measured and paid separately)
using glazed tiles of approved make and size including cost of materials, labour, complete as Sqm 1484.00
per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 30x60 cms 6mm
thick with border of size 30 x 10 cms. (P.No.106, I.No. 14.41.2 of PWD SR 2015-16)

14.41.3 KSRB 14-17.2 : Providing skirting, dado, rises of steps with colour glazed tiles on 10mm
thick cement plaster 1:3 and jointed with white cement slurry over rough plaster surface
( excluding cost of rough plastered surface which should be measured and paid separately)
using glazed tiles of approved make and size including cost of materials, labour, complete as Sqm 1119.00
per specifications. Specification No.KBS 14.16, 14.17 - Colour glazed tiles 30x45 cms 6mm
thick with border of size 30 x 10 cms.

Page No. 106


14.42 KSRB 14-18.1 : Providing skirting, dado, rises of steps with marble slabs not exceeding 30
cms. height on 10 cms. thick cement mortar 1:3 and jointed with white cement slurry over
rough plaster surface (excluding cost of rough plastered which should be measured and paid
separately ) using marble slab with machine cut edges upto 25cms. thick including cost of Sqm 3269.00
materials, labour, complete as per specifications. Specification No.KBS 14.19

14.43 Providing and fixing Special make glazed Vitrified tiles (Granomite finish) of approved
make, quality and colour of size 600x600x10mm thick fixed on existing flooring with a
special roffe adhesive for flooring and skirting etc., complete including providing spears at Sqm 1190.00
required interval and removing stains etc., complete. (P.No. 107, I.No. 14.43 of SR 2015-
16).
14.44 Providing flooring with 60 cms.x 60 cms. size Vitrified glazed tiles of approved quality &
make, fixed on top of existing flooring fixed with suitable adhesive, including cutting the Sqm 1069.00
tiles to the required size and fixing etc., complete.

Page 86 of 350
14.45 Providing vitrified tiles 60 x 60cms of approved make, shade and size for flooring laid on a
bed of 12mm thick cement mortar 1:3 mix, flush pointing with white cement using colour
pigment, including cost of materials, labour, curing complete as per specification. Sqm 1112.00

14.46 Providing and laying pattern flooring for staircase treads and risers using the combination
of 20mm thick ruby red granite @ 66%,20 mm thick grey granite @ 20%, 20mm thick,
20mm thick black granite 14%. The granite materials are laid on existing bed of CM 1:3
20mm thick pointed with colour pigment, including full rounding for nosing, flaming the Sqm 5724.00
ruby red granite for 50 mm wide curing etc., complete as per specification. (P.No. 107, I.No.
14.46 of PWD SR 2015-16)

14.47.1 Providing and laying flooring using prepolished, water cut/gang saw 19mm thick granite
laid over bed of 20mm thick 1:4 cm & jointed with neat cement slurry mixed with pigment
to mach shade of granite slabs including laying POP on finished surface and cleaning the
surface, including the cost of all materials and labours etc., complete as per specifications. - Sqm 2619.00
using silver grey granite / Multy Red / Ruby Red / Black / HassanGreen Granite of
width not less than 1200mm (P.No.107, I.No.14.47.1 of PWD SR 2015-16)

14.47.2 Providing and laying flooring using prepolished, water cut/gang saw 19mm thick granite
laid over bed of 20mm thick 1:4 cm & jointed with neat cement slurry mixed with pigment
to mach shade of granite slabs including laying POP on finished surface and cleaning the
surface, including the cost of all materials and labours etc., complete as per specifications. - Sqm 2301.00
using silver grey granite / Multy Red / Ruby Red / Black / HassanGreen Granite of
width not less than 900mm

14.47.3 Providing and laying flooring using prepolished, water cut/gang saw 19mm thick granite
laid over bed of 20mm thick 1:4 cm & jointed with neat cement slurry mixed with pigment
to mach shade of granite slabs including laying POP on finished surface and cleaning the
surface, including the cost of all materials and labours etc., complete as per specifications. - Sqm 1276.00
using 10mm thick silver grey granite / Multy Red / Ruby Red/ Black / Hassan Green
Granite tiles

14.47.4 Providing and laying flooring using prepolished, water cut/gang saw 19mm thick granite
laid over bed of 20mm thick 1:4 cm & jointed with neat cement slurry mixed with pigment
to mach shade of granite slabs including laying POP on finished surface and cleaning the
surface, including the cost of all materials and labours etc., complete as per specifications. - Sqm 2619.00
using 19mm thick Raw Silk / Black Pearl granite of width not less than 1200 mm

14.47.5 Providing and laying flooring using prepolished, water cut/gang saw 19mm thick granite
laid over bed of 20mm thick 1:4 cm & jointed with neat cement slurry mixed with pigment
to mach shade of granite slabs including laying POP on finished surface and cleaning the
surface, including the cost of all materials and labours etc., complete as per specifications. - Sqm 2396.00
using 19mm thick Raw Silk / Black Pearl granite of width not less than 900 mm

Page No. 107


14.48.1 Providing and laying flooring for corridors/lobbies using combination of pre polished 19
mm thick water cut/gang saw Grey Granite, Black Granite, and strips of 50mm wide pre
flamed grey granite using pre polished grey granite 19mm thick 76%, Pre polished black
granite 19mm thick @ 2% and preflamed 19mm thick grey granite @22% over existing Sqm 2556.00
cement concrete bed in CM 1:4 average 20mm thick pointed with white cement/colour
pigment etc., complete. - using 19mm thick granite width not less than 1200mm
(P.No.108, I.No.14.48.1 of PWD SR 2015-16)

14.48.2 Providing and laying flooring for corridors/lobbies using combination of pre polished 19
mm thick water cut/gang saw Grey Granite, Black Granite, and strips of 50mm wide pre
flamed grey granite using pre polished grey granite 19mm thick 76%, Pre polished black
granite 19mm thick @ 2% and preflamed 19mm thick grey granite @22% over existing Sqm 1582.00
cement concrete bed in CM 1:4 average 20mm thick pointed with white cement/colour
pigment etc., complete. - using 10mm thick granite slab

Page 87 of 350
14.49 Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold
granite, grey granite in CM 1:3 proportion cut to required shape, pattern with paper joints,
finished with cement mortal using white cement and colour pigments to match the colour of Sqm 3527.00
slab making through jointing with sealant, making holes 25mmx12mm grooves in joints
including curing etc., complete. (P.No. 108, I.No. 14.49 of PWD SR 2015-16)

14.50 "Providing and fixing skirting of 300mm high using prepolished water cut/gang saw of
19mm thick grey granite 0.5mm wide chamfered width and depth and fixing in CM 1:4 of m 698.00
20mm thick after chipping the walls etc., complete.”
14.51 Providing and laying Hassan Green granite flooring for staircase, treads and rises using pre
polished 20 mm thick water cut green Granite slab laid over existing cement concrete bed in
CM 1:3, average 20mm thick including full rounding for nosing , cutting 3 line grooves not Sqm 3987.00
more than 2 mm wide for antiskidding, curing etc.,complete.
14.52 Providing and laying plat form using prepolished, water cut / gang saw 40mm thick
telephonic Black Granite. laid on existing vertical -supports and fixing in CM 1:3
proportion. Including cutting to required shape, pattern with paper joints, including full
rounding for nosing, finished with cement mortar, pointed with colour pigments to match the
colour of slab making through jointing with sealant, making holes 25mm x 12mm grooves in Sqm 3614.00
joints including curing. (P.No. 108, I.No. 14.52 of PWD SR 2015-16)

14.53 Providing full nosing for 40mm thick granite slab using required machinery including cost
and conveyance of all materials, labour for all items of work, HOM of equipment etc., m 475.00
complete as per specification
14.54 Providing half nosing for 40mm thick granite slab using required machinery including cost
and conveyance of all materials, labour for all items of work, HOM of equipment etc., m 317.00
complete as per specification
14.55 Providing full nosing for 20mm thick granite slab using required machinery including cost
and conveyance of all materials, labour for all items of work, HOM of equipment etc., m 238.00
complete as per specification. (P.No. 108, I.No. 14.55 of PWD SR 2015-16)
Page No. 108
14.56 Providing half nosing for 20mm thick granite slab using required machinery including cost
and conveyance of all materials, labour for all items of work, HOM of equipment etc., m 158.00
complete as per specification
14.57 Providing and fixing for flooring 40mm thick sadarhalli grey flammed granite slab for bath
areas in Bathrooms over a bed of 25mm thick CM 1:6 and fixing granite slab with CM 1:3. Sqm 1891.00

14.58 Providing and fixing granite flooring in combination of 19mm thick (Avg) gang saw water
cut LAKARED granite with 86% and with 14% of 19mm thicl (avg) Black granite in CM
1:4 proportion with a coat of rough plastering using CM 1:4, cut to required shape, pattern
with paper joints, finished with cement mortar using white cement and colour pigments to
match the colour of slab making through jointing with sealant, grooves in joints including Sqm 3722.00
cost of curing etc., complete including cost and conveyance of all materials, labour for all
items of work, HOM of equipment etc., complete as per specification. (P.No. 109, I.No.
14.58 of PWD SR 2015-16)

14.59 Providing and fixing for flooring 20mm thick gang saw water cut telephonic black granite in
CM 1:4 proportion with a coat of rough plastering using CM 1:4, cut to required shape,
pattern with paper joints, finished with cement mortar using white cement and colour
pigments to match the colour of slab making through jointing with sealant, grooves in joints Sqm 2631.00
including cost of curing etc., complete including cost and conveyance of all materials, labour
for all items of work, HOM of equipment etc., complete as per specification

14.60 Providing and fixing 20mm thick gang saw water cut LAKARED granite in CM 1:4
proportion with a coat of rough plastering using CM 1:4, cut to required shape, pattern with
paper joints, finished with cement mortar using white cement and colour pigments to match
the colour of slab making through jointing with sealant, grooves in joints including cost of Sqm 3695.00
curing etc., complete including cost and conveyance of all materials, labour for all items of
work, HOM of equipment etc., complete as per specification .

Page 88 of 350
14.61.1 Providing and fixing for flooring 20mm thick gang saw water cut sadarhalli gray granite
in CM 1:4 proportion, cut to required shape, pattern with paper joints, finished with cement
mortar using white cement and colour pigments to match the colour of slab making through sqm 1986.00
jointing with sealant, groves in joints including cost of curing - minimum width of
1200mm
14.61.2 Providing and fixing for flooring 20mm thick gang saw water cut sadarhalli gray granite
in CM 1:4 proportion, cut to required shape, pattern with paper joints, finished with cement
mortar using white cement and colour pigments to match the colour of slab making through Sqm 1889.00
jointing with sealant, groves in joints including cost of curing - minimum width of 900mm.

14.62 Providing and laying/fixing cement base, precast, pre polished cement concrete, designer
tiles 25mm thick for flooring conforming to IS 1237 heavy duty tiles for flooring, treads of
steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush
pointing using white cement, including cost of materials, including cutting, griding the edge Sqm 1085.00
to half/full round wherever required, labour, curing complete as per specification. (P.No.
109, I.No. 14.62 of PWD SR 2015-16)

Page No. 109


14.63 Providing and fixing Ceramic tiles of size 400x400mm for flooring, threads, steps and
landing, laid on a bed of 20mm thick cement mortar 1:3 mix flush pointing with white
cement mixed with matching colour pigment including curing, cleaning etc., complete. The Sqm 1075.00
work includes cost of all materials, labour charges for all items of work, hire charges for
equipment, , etc., complete as per specification
14.64 Providing and fixing colour glazed tiles of size 300mmx600mm for walls with borders of
size 300x100mm, set in Cement Mortar 1:3 and pointed with white cement with matching
colour pigment with necessary curing, cleaning including providing and removing
scaffolding wherever necessary etc., complete. The work includes cost of all materials, Sqm 1164.00
labour charges for all items of work, hire charges for equipment, etc., complete as per
specification.

14.65 Providing and fixing colour glazed tiles of size 300mmx450mm for walls with borders of
size 300x100mm, set in Cement Mortar 1:3 and pointed with white cement with matching
colour pigment with necessary curing, cleaning including providing and removing
scaffolding wherever necessary etc., complete. The work includes cost of all materials, Sqm 957.00
labour charges for all items of work, hire charges for equipment, etc., complete as per
specification.

14.67.1 Providing and fixing of wall cladding using 20 mm thick gang saw water cut granite in CM
1:3 proportion cut to required shape patron with paper joint finished with cement mortar
using white cement and colour pigments to match the colour of slab making through jointing
with sealant, making holes 25mm × 12mm grooves in joints including curing etc., complete - sqm 2295.00
with grey granite 20mm thick gang saw with minimum width 1200

14.67.2 Providing and fixing of wall cladding using 20 mm thick gang saw water cut granite in CM
1:3 proportion cut to required shape patron with paper joint finished with cement mortar
using white cement and colour pigments to match the colour of slab making through jointing
with sealant, making holes 25mm × 12mm grooves in joints including curing etc., complete - sqm 2162.00
with Sadarahalli granite 20mm thick gang saw with minimum width 1200

14.68 Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm
thick cement mortar 1:3 & jointed with Adhesive / cement slurry over rough plaster surface
excluding cost of rough plasterd surface and the surface is painted with red apex paint and Sqm 1650.00
black apex paint into the groves.
14.69 Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade
Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of
50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft
vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all Sqm 12800.00
necessary bending and cutting as per the desing and site condition. The frame work finally to
be finished with 12mm BWP plywood to receive the SS sheet on it uniformly

Page 89 of 350
14.70 Providing and laying of teak wooden polished flooring of 12mm thick, high density timber
of approved colour and design with end trims, transition, profiles, beading, 15mm thick felt, Sqm 4950.00
and 20 micron polyester film with 4mm thick foam underlay etc.,
Page No. 110
14.71 Providing and laying of Modular wooden polished flooring of 12mm thick, high density
timber of approved colour and design with end trims, transition, profiles, beading, 15mm
thick felt, and 20 micron polyester film with 4mm thick foam underlay etc., Sqm 2900.00

14.72 Providing Venyl flooring of approved quality and make, fixed on the top of existing flooring
fixed with suitable adhesive, including cutting to the requied size and fixing etc. complete Sqm 625.00

Page No. 111

15.0 15.FINISHING WORK

15.1 KSRB 15.1.1 Providing flush pointing to square rubble, course or uncoursed stone masonry
with cement mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining,
including cost of materials, labour, curing complete as per specifications. Sqm 97.00

15.2 KSRB 15.1.2 Providing flush pointing to square rubble, course or uncoursed stone masonry
with cement mortar 1:4, 20mm deep, after raking joints to depth of 20mm nicely lining,
including cost of materials, labour, curing complete as per specifications. Sqm 95.00

15.3 KSRB 15.1.3 – do – Providing ruled pointing to coursed stone masonry with cement mortar
1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost of Sqm 98.00
materials, labour, curing complete as per specifications.
15.4 KSRB 15.1.4 Providing ruled pointing to coursed stone masonry with cement mortar 1:4,
20mm deep, after raking joints to depth of 20mm nicely lining, including cost of materials, Sqm 95.00
labour, curing complete as per specifications.
15.5 KSRB 15.1.5 Providing raised and cut pointing to coursed stone masonry with cement
mortar 1:3, 20mm, after raking joints to depth of 20mm nicely lining, including cost of Sqm 143.00
materials, labour, curing complete as per specifications.
15.6 KSRB 15.1.6 Providing raised and cut pointing to coursed stone masonry with cement
mortar 1:4, 20mm, after raking joints to depth of 20mm nicely lining, including cost of Sqm 139.00
materials, labour, curing complete as per specifications.
15.7 KSRB 15.2.1 Providing flush pointing to stone slab pavements, with cement mortar 1:3,
after raking joints, nicely lining, including cost of materials, labour, curing complete as per Sqm 34.00
specifications.
15.8 KSRB 15.2.2 Providing ruled pointing to stone slab pavements with cement mortar 1:3,
20mm deep, after raking joints , including cost of materials, labour, curing complete as per Sqm 35.00
specifications.
15.9 KSRB 15.3.1 Providing 12mm thick cement plaster in single coat with cement mortar 1:3, to
brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 181.00
per specifications.
15.10 KSRB15-3.2 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4,
to brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 165.00
per specifications.
15.11 KSRB15-3.3 : Providing 12mm thick cement plaster in single coat with cement mortar 1:6,
to brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 150.00
per specifications.
15.12 KSRB15-3.4 : Providing 15mm thick cement plaster in single coat with cement mortar 1:3,
to brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 205.00
per specifications.

Page 90 of 350
15.13 KSRB15-3.5 : Providing 15mm thick cement plaster in single coat with cement mortar 1:4,
to brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 186.00
per specifications.(P.No. 112, I.No. 15.13 of PWD SR 2015-16)
15.14 KSRB15-3.6 : Providing 15mm thick cement plaster in single coat with cement mortar 1:6,
to brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 167.00
per specifications.
15.15 KSRB15-3.7 : Providing 18mm thick cement plaster in single coat with cement mortar 1:3,
to brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 244.00
per specifications. (P.No. 112, I.No. 15.15 of PWD SR 2015-16)

Page No. 113


15.16 KSRB15-3.8 : Providing 18mm thick cement plaster in single coat with cement mortar 1:4,
to brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 221.00
per specifications.
15.17 KSRB15-3.9 :Providing 18mm thick cement plaster in single coat with cement mortar 1:6, to
brick masonry including rounding off corners wherever required smooth rendering, :
Providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 198.00
per specifications.
15.18 KSRB15-3.10 : Providing 20mm thick cement plaster in single coat with cement mortar 1:3,
to stone masonry & concrete surface including rounding off corners wherever required
smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, Sqm 259.00
curing complete as per specifications.
15.19 KSRB15-3.11 : Providing 20mm thick cement plaster in single coat with cement mortar 1:4,
to stone masonry & concrete surface including rounding off corners wherever required
smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, Sqm 234.00
curing complete as per specifications.
15.20 KSRB15-3.12 :Providing 20mm thick cement plaster in single coat with cement mortar 1:6,
to stone masonry & concrete surface including rounding off corners wherever required
smooth rendering, : Providing and removing scaffolding, including cost of materials, labour, Sqm 208.00
curing complete as per specifications.
15.21 KSRB15-3-13 : Providing 12mm thick cement plaster in single coat with cement mortar 1:3,
to ceiling including rounding off corners wherever required smooth rendering, : Providing
and removing scaffolding, including cost of materials, labour, curing complete as per Sqm 193.00
specifications. (P.No. 113, I.No. 15.21 of PWD SR 2015-16)
15.22 KSRB15-3.14 : Providing 12mm thick cement plaster in single coat with cement mortar 1:4,
to ceiling including rounding off corners wherever required smooth rendering, : Providing
and removing scaffolding, including cost of materials, labour, curing complete as per Sqm 178.00
specifications.
15.23 KSRB15-4.1 Extra for providing and mixing waterproofing compound in cement plaster
work at one kg per bag or in the proportion recommended by the manufacturers, for cement
mortar 1:3, 12mm thick cost of materials complete as per specifications. Sqm 7.00

15.24 KSRB15-4.2 Extra for providing and mixing waterproofing compound in cement plaster
work at one kg per bag or in the proportion recommended by the manufacturers, for cement
mortar 1:4, 12mm thick cost of materials complete as per specifications. Sqm 6.00

15.25 KSRB15-4.3 Extra for providing and mixing waterproofing compound in cement plaster
work at one kg per bag or in the proportion recommended by the manufacturers, for cement
mortar 1:4, 15mm thick cost of materials complete as per specifications. Sqm 7.00

15.26 KSRB15-4.4 Extra for providing and mixing waterproofing compound in cement plaster
work at one kg per bag or in the proportion recommended by the manufacturers, forcement
mortar 1:4, 18mm thick cost of materials complete as per specifications. Sqm 8.00

Page 91 of 350
15.27 KSRB15-4.5 Extra for providing and mixing waterproofing compound in cement plaster for
stone masonry work at one kg per bag or in the proportion recommended by the
manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per Sqm 9.00
specifications.
15.28 KSRB15-4.6 Extra for providing and mixing waterproofing compound in cement plaster for
birck masonry work at one kg per bag or in the proportion recommended by the
manufacturers, for cement mortar 1:3, 20mm thick cost of materials complete as per Sqm 13.00
specifications.
15.29 KSRB15-4.7 Extra for providing and mixing waterproofing compound in cement plaster for
brick masonry work at one kg per bag or in the proportion recommended by the
manufacturers, for cement mortar 1:4, 20mm thick cost of materials complete as per Sqm 10.00
specifications.
15.30 KSRB15-5.1 : Providing rough cement plastering 15mm thick in single coat with cement
mortar 1:4, to brick masonry for base of dadooing works with sand of approved quality,
providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 177.00
per specifications. (P.No. 113, I.No. 15.30 of PWD SR 2015-16)

Page No. 114


15.31 KSRB15-5.2 : Providing rough cement plastering 15mm thick in single coat with cement
mortar 1:6, to brick masonry for base of dadooing works with sand of approved quality,
providing and removing scaffolding, including cost of materials, labour, curing complete as Sqm 157.00
per specifications.
15.32 KSRB15-6 : Providing floating coat of cement to plastering and finishing smooth, including
Sqm 19.00
cost of materials, labour, curing complete as per specifications.
15.33 KSRB15-7 : Providing lime rendering for plastering to wall and ceiling, including cost of
Sqm 25.00
materials, labour, curing complete as per specifications.
15.34 KSRB 15.8.1 Providing and fixing plaster mesh 100mm wide manufactured out of hot
dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm
width, along route of walls chipped for services, junction between RCC and brick walls m 28.00
including cost of materials, labour for fixing complete as per specifications. ( length of mesh
only be measured for payment )
15.35 KSRB 15.8.2 Providing and fixing plaster mesh 150mm wide manufactured out of hot
dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm
width, along route of walls chipped for services, junction between RCC and brick walls m 36.00
including cost of materials, labour for fixing complete as per specifications. ( length of mesh
only be measured for payment )
15.36 KSRB 15.8.3 Providing and fixing plaster mesh 200mm wide manufactured out of hot
dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm
width, along route of walls chipped for services, junction between RCC and brick walls
including cost of materials, labour for fixing complete as per specifications. (length of mesh m 43.00
only be measured for payment) (P. No. 114, I.No. 15.36 of SR 2015-16).

15.37 KSRB 15.9 Providing and fixing corner beads 45x45mm size manufactured out of hot
dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm
width, along exposed corners of walls, coloumns, lintels including cost of materials, labour m 26.00
for fixing complete . (length of mesh be measured for payment)
15.38 KSRB 15.10.1 Providing white washing to new wall surface in two coats with lime of
approved quality, to give an even shade including cost of materials, labour, complete as per Sqm 8.00
specifications.
15.39 KSRB 15.10.2 Providing white washing for every one additional coat with lime of approved
quality, to give an even shade including cost of materials, labour, complete as per Sqm 4.00
specifications.
15.40 KSRB 15.10.3 Providing white washing to ceiling and / or sloping roof surface in two coats
with lime of approved quality, to give an even shade including cost of materials, labour, Sqm 9.00
complete as per specifications.
15.41 KSRB 15.10.4 Providing white washing to ceiling and / or sloping roof surface with
additional one coat with lime of approved quality, to give an even shade including cost of Sqm 4.00
materials, labour, complete as per specifications.

Page 92 of 350
15.42 KSRB 15.11.1Providing cement washing to rough wall surface in one coat with portland
cement slurry to give an even shade after throughly brooming the surface to remove all dirt,
dust, mortar drops and other foreign matter including cost of materials, labour, complete as Sqm 7.00
per specifications.
Page No. 115
15.43 KSRB 15.11.2 Providing cement washing on iron surface in one coat with portland cement
slurry mixed with boiled linseed oil to give an even surface after thoroughly cleaning the
surface to remove all dirt, dust, mortar drops and other foreign matter including cost of Sqm 72.00
materials, labour, complete as per specifications.
15.44 KSRB 15.12.1Providing Gopi colour washing to new wall surface in two coats with lime
and gopi colour of approved quality, to give an even shade after thoroughly brooming the
surface to remove all dirt, dust, mortar drops and other foreign matter including cost of Sqm 11.00
materials, labour, complete as per specifications.
15.45 KSRB 15.12.2 Providing Gopi colour washing to new wall surface in one coat with lime and
gopi colour of approved quality, to give an even shade after thoroughly brooming the surface
to remove all dirt, dust, mortar drops and other foreign matter including cost of materials, Sqm 6.00
labour, complete as per specifications.
15.46.1 KSRB15-13 : Applying of distemper KSRB 15-13.1 : Providing and applying one coat
distemper primer of approved brand on wall surface after throughly brooming the surface to
remove all dirt, dust, mortar drops and other foreign matter including preparing the surface, Sqm 25.00
even and sand paper smooth, cost of materials, labour, complete as per specifications. -wall
surface-
15.46.2 KSRB 15-13.2 : Extra over Item 15-13.1 for applying one coat of distemper primer over
Sqm 2.00
ceiling and / or sloping roof as per specifications.
15.47.1 KSRB 15-13.3 : Providing and applying two coats dry distemper of approved brand, and
shade on wall surface including priming coat and whitening after throughly brooming the
surface to remove all dirt, dust, mortar drops and other foreign matter including preparing Sqm 50.00
the surface even and sand paper smooth, cost of materials, labour, complete as per
specifications.
15.47.2 KSRB 15-13.4 : Extra over Item 15-13.3 for applying distemper primer over ceiling and / or
Sqm 4.00
sloping roof as per specifications.
15.48.1 KSRB 15-13.5 : Providing and applying one coat on old surface dry distemper of approved
brand, and shade on wall surface after thoroughly brooming the surface clean of all gease,
dirt, loose pieces of scales including preparing the surface even and sand paper smooth, cost Sqm 15.00
of material, labour, complete as per specifications. -wall surface-

15.48.2 KSRB 15-13.6 : Extra over Item 15-13.5 for applying distemper over ceiling and /or sloping
Sqm 1.00
roof as per specifications.
Page No. 116
15.48.3 KSRB 15-13.7 : Extra for providing and applying every subsequent cost of dry distemper of
approved brand , for item no. 15-13.3 and 15-13.5 of approved shade on wall surface cost of Sqm 10.00
materials, labour, complete as per specifications.
15.49.1 KSRB 15-14.1 : Providing and applying two coats with oil bound washable distemper of
approved brand and shade on wall surface including priming coat with distemper primer
after throughly brooming the surface free from mortar drops and other foreign matter Sqm 71.00
including preparing the surface even and sand paper smooth, cost of materials, labour,
complete as per specifications.
15.49.2 KSRB 15-14.2 : Extra over Item 15-14.1 for applying oil bound washable distemper on
Sqm 5.00
ceiling and / or sloping roof as per specifications.
15.50.1 KSRB 15-14.3 : Providing and applying one coat with oil bound washable distemper of
approved brand and shade on wall surface to give an even shade after throughly brooming
the surface free from all grease, dirt, loose peases of scales, including preparing the surface Sqm 29.00
even and sand paper smooth, cost of materials, labour, complete as per specifications.

15.50.2 KSRB 15-14.4 : Extra over Item 15-14.3 for applying one coat with oil bound washable
Sqm 2.00
distemper on ceiling and / or sloping roof as per specifications.

Page 93 of 350
15.51.1 KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of
approved brand on wall surface to give an even approved shade after thoroughly brushing
the surface, free from mortar drops and other foreign matter including preparing the surface Sqm 71.00
even and sand paper smooth, cost of materials, labour, complete as per specifications.

15.51.2 KSRB 15-15.1 : Providing and applying painting in two coats with plastic emulsion paint of
approved brand on wall surface to give an even approved shade after thoroughly brushing
the surface, free from mortar drops and other foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour, complete as per specifications. - with Sqm 90.00
primer. (P. No. 116, I.No. 15.51.2 of SR 2015-16).

15.51.3 KSRB 15-15.2 : Extra over Item 15-15.1 for painting two coats with plastic emulsion paint
of approved brand and shade on ceiling and / or sloping roof as per specifications. (P. No. Sqm 4.00
116, I.No. 15.51.3 of SR 2015-16).
Page No. 117
15.52.1 KSRB 15-15.3 : Providing and applying painting in one coat with plastic emulsion paint of
approved brand and manufacture on wall surface to give an even approved shade after
throughly brushing the surface, free from mortar drops and other foreign matter including Sqm 45.00
preparing the surface even and sand paper smooth, cost of materials, labour, complete as per
specifications.
15.52.2 KSRB 15.15.4 : Extra over Item 15-15.3 for painting with one coat plastic emulsion paint of
approved brand and shade on ceiling and / or sloping roof as per specifications. Sqm 3.00

15.52.3 KSRB 15-15.5 : Extra for providing and applying every subsequent coat of painting with
plastic emulsion paint of approved brand and shade for Item no.15-15.1 and 15-15.3 cost of Sqm 30.00
materials, labour, complete as per specifications.
15.53.1 KSRB 15-16.1 : Providing and finishing external walls in two coats with waterproof cement
paint of approved brand and shade to give an even shade after throughly brooming the
surface to remove all dirt and loose powdered material, free from mortar drops and other Sqm 69.00
foreign matter cost of materials, labour, complete as per specifications.

15.53.2 KSRB 15-16.1 : Providing and finishing external walls in two coats with waterproof cement
paint of approved brand and shade to give an even shade after throughly brooming the
surface to remove all dirt and loose powdered material, free from mortar drops and other Sqm 84.00
foreign matter cost of materials, labour, complete as per specifications. - with primer. (P. No.
117, I.No. 15.53.2 of SR 2015-16).
15.53.3 KSRB 15-16.3 : Extra for providing and applying every subsequent coat of waterproofing
cement paint of approved brand and shade for Item no.15-16.1 cost of materials, labour, Sqm 27.00
complete as per specifications.
15.54.1 KSRB 15-16.2 : Providing and finishing external walls in one coat with waterproof cement
paint of approved brand and shade to give an even shade after throughly brooming the
surface to remove all dirt and loose powdered material, free from mortar drops and other Sqm 39.00
foreign matter cost of materials, labour, complete as per specifications.

15.54.2 KSRB 15-16.2 : Providing and finishing external walls in one coat with waterproof cement
paint of approved brand and shade to give an even shade after throughly brooming the
surface to remove all dirt and loose powdered material, free from mortar drops and other Sqm 42.00
foreign matter cost of materials, labour, complete as per specifications. - with primer

15.54.3 KSRB 15-16.3 : Extra for providing and applying every subsequent coat of waterproofing
cement paint of approved brand and shade for Item no.15-16.1 and 15-16.2 cost of materials, Sqm 27.00
labour, complete as per specifications.
15.55 KSRB 15-17.1 : Applying priming coat over new wood surface and / or wood based surface
with white lead paint priming including preparing the surface after thoroughly cleaning oil,
grease, dirt and foreign matter, sand papering and knotting ready mix paint including cost of Sqm 33.00
materials, labour, complete as per specifications.

Page 94 of 350
15.56 KSRB 15-17.2 : Applying priming coat over new wood surface and / or wood based surface
after brushing with wood primer pink paint including preparing the surface after thoroughly
cleaning oil, grease, dirt and foreign matter, sand papering and knotting ready mix paint Sqm 36.00
including cost of materials, labour, complete as per specifications.

Page No. 118


15.57 KSRB 15-17.3 : Applying priming coat over new wood surface and / or wood based surface
after brushing with aluminium paint primer, water resistant including preparing the surface
after thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting Sqm 32.00
ready mix paint including cost of materials, labour, complete as per specifications.

15.58 KSRB 15-17.4 : Applying priming coat over new wood surface and / or wood based surface,
after brushing with ready mix enamel priming paint including preparing the surface after
thoroughly cleaning oil, grease, dirt and foreign matter, sand papering and knotting ready Sqm 31.00
mix paint including cost of materials, labour, complete as per specifications.

15.59 KSRB 15-17.5 : Applying priming coat over new wood surface and / or wood based surface
after preparing the surface after throughly cleaning oil, grease, dirt and foreign matter, sand
papering and knotting liquid wood filler, for varnish including cost of materials, labour, Sqm 41.00
complete as per specifications. (P.No. 118, I.No. 15.59 of SR 2015-16).

15.60.1 KSRB 15-17.6 : Providing and applying painting two coats ( excluding priming coat ) on
new wood surface and / or wood based surface with enamel paint to give an even shade,
cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of Sqm 84.00
materials, labour, complete as per specifications. (P.No. 118, I.No. 15.60.1 of SR 2015-16).

15.60.2 KSRB 15-17.8 : Extra over Item No. 15-17.6 for applying every subsequent coat of enamel
paint to give an even shade after cleaning the surface of all dirt, dust and foreign matter, sand
papering including cost of materials, labour, complete as per specifications. Sqm 48.00

15.61.1 KSRB 15-17.7 : Providing and applying painting one coat ( excluding priming coat ) on new
wood surface and / or wood based surface with enamel paint to give an even shade after
cleaning the surface of all dirt, dust and foreign matter, sand papering including cost of Sqm 52.00
materials, labour, complete as per specifications.
15.61.2 KSRB 15-17.8 : Extra over Item No.15-17.7 for applying every subsequent coat of enamel
paint to give an even shade after cleaning the surface of all dirt, dust and foreign matter, sand
papering including cost of materials, labour, complete as per specifications. Sqm 48.00

15.62.1 KSRB 15-17.9 : Applying varnish two coats ( excluding priming coat ) on new wood surface
and / or wood based surface undercoating with flatting varnish and finishing coat with
varnish to give an even shade after cleaning the surface of all dirt, dust and foreign matter, Sqm 65.00
sand papering so as to produce smooth dry, mat surface including cost of materials, labour,
complete as per specifications.
15.62.2 KSRB 15-17.11 : Extra over Item No. 15-17.9 and 15-17.10 for applying every subsequent
coat of varnish to produce a smooth dry and mat surface after cleaning the surface of all dirt,
dust and foreign matter, including cost of materials, labour, complete as per specifications. Sqm 32.00

Page No. 119


15.63.1 KSRB 15-17.10 : Providing and applying varnishing one coat ( excluding priming coat ) on
previously varnished wood / or wood based surface to give an even surface after cleaning the
surface of all dirt, dust and foreign matter, sand papering so as to produce a smooth dry and Sqm 36.00
mat surface, including cost of materials, labour, complete as per specifications.

15.63.2 KSRB 15-17.11 : Extra over Item No. 15-17.9 and 15-17.10 for applying every subsequent
coat of varnish to produce a smooth dry and mat surface after cleaning the surface of all dirt,
dust and foreign matter, including cost of materials, labour, complete as per specifications. Sqm 32.00

Page 95 of 350
15.64 KSRB 15-17.12 : Providing and applying polishing with french polish on new wood surface
and / or wood based surface to give an even surface after cleaning the surface of all dirt, dust
and foreign matter, sand papered smooth, including cost of wood filler and materials, labour, Sqm 135.00
complete as per specifications.
15.65 KSRB 15-17.13 : Providing and applying polishing with french polish over previously
polished wood or wood based surface to give an even surface after cleaning the surface of all
dirt, dust and foreign matter, sand papered smooth, including cost of wood filler and Sqm 70.00
materials, labour, complete as per specifications.
15.66 KSRB 15-17.14 : Providing and applying wax polish in two coats on new wood surface
and / or wood based surface, with bees wax polish in proportion of 2:1.5:1:0.5 ( 2 bees wax :
1.5 linseed oil : 1 turpentine oil : 0.5 varnish by weight ) to give an even surface after Sqm 68.00
cleaning the surface of all dirt, dust and foreign matter, sand papered smooth, including cost
of materials, labour, complete as per specifications.
15.67 KSRB 15-17.15 : Providing and applying wax polish in single coat on new wood surface and
/ or wood based surface, with bees wax polish in proportion of 2:1.5:1:0.5 ( 2 bees wax : 1.5
linseed oil : 1 turpentine oil : 0.5 varnish by weight ) to give an even surface after cleaning Sqm 34.00
the surface of all dirt, dust and foreign matter, sand papered smooth, including cost of
materials, labour, complete as per specifications.
15.68 KSRB 15-17.16 : Providing and applying painting two coats ( excluding priming coat ) on
new wood surface and / or wood based surface with coal tar paint to give an even shade after
cleaning the surface of all dirt, dust and foreign matter, including cost of materials, labour, Sqm 39.00
complete as per specifications.
15.69 KSRB 15-17.17 : Providing and applying painting one coat ( excluding priming coat ) on
new wood surface and / or wood based surface with coal tar paint to give an even shade after
cleaning the surface of dirt, dust and foreign matter, including cost of materials, labour, Sqm 26.00
complete as per specifications.
Page No. 120
15.70 KSRB 15-17.18 : Providing and applying painting one coat ( excluding priming coat) on
previously painted wood surface and / or wood based surface with coal tar paint to give an
even shade after cleaning the surface of all dirt, dust and foreign matter, including cost of Sqm 22.00
materials, labour, complete as per specifications.
15.71 KSRB 15-17.19: Providing and applying painting one coat ( excluding priming coat ) on
previously painted wood surface and / or wood based surface with black japan paint to give
an even shade after cleaning the surface of all dirt, dust and foreign matter, including cost of Sqm 46.00
materials, labour, complete as per specifications.
15.72 KSRB 15-17.20: Applying additional one coat ( excluding priming coat) on previously
painted wood surface and / or wood based surface with black japan paint to give an even
shade after cleaning the surface of all dirt, dust and foreign matter, including cost of Sqm 42.00
materials, labour, complete as per specifications.
15.73 KSRB 15-18.1 : Applying red lead ready mix priming coat over new steel or other metal
surface including preparing the surface after throughly cleaning oil, grease, dirt and other
foreign matter, and scoured with wire brushes, fine steel wool, sand papers including cost of Sqm 29.00
materials, labour, complete as per specifications.
15.74 KSRB 15-18.2 : Providing and applying enamel metal paint two coats ( excluding priming
coat ) over new steel or other metal surface brushing to give an even shade after cleaning oil,
grease, dirt and other foreign matter, including cost of materials, labour, complete as per Sqm 82.00
specifications. (Page No. 120 Item No. 15.74 of SR 2015-16).

15.75 KSRB 15-18.3 : Providing and applying enamel metal paint one coat (excluding priming
coat ) on previously painted steel or other metal surface brushing to give an even shade after
cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, Sqm 51.00
complete as per specifications.
15.76 KSRB 15-18.4 : Providing and applying alluminium paint two coats (excluding priming coat
) over new steel or other metal surface brushing to give an even shade after cleaning oil,
grease, dirt and other foreign matter, including cost of materials, labour, complete as per Sqm 56.00
specifications.

Page 96 of 350
15.77 KSRB 15-18.5 : Providing and applying alluminium paint one coat (excluding priming
coat ) on previously painted steel or other metal surface brushing to give an even shade after
cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, Sqm 35.00
complete as per specifications.
15.78 KSRB 15-18.6 : Providing and applying black japan paint one coat (excluding priming coat )
on previously painted steel or other metal surface brushing to give an even shade after
cleaning oil, grease, dirt and other foreign matter, including cost of materials, labour, Sqm 33.00
complete as per specifications.
Page No. 121
15.79 KSRB 15-18.7 : Extra for applying every subsequent black japan paint on previously painted
steel or other metal surface brushing to give an even shade after cleaning of oil, grease, dirt
and other foreign matter, including cost of materials, labour, complete as per specifications. Sqm 30.00

15.80 KSRB 15-19.1 : Providing and applying ready mix priming coat over concrete / masonry /
asbestos cement sheet / plastered surfaces including preparing the surface after thoroughly
cleaning of oil, grease, dirt and other foreign matter, and sand papering including cost of Sqm 26.00
materials, labour, complete as per specifications.
15.81 KSRB 15-19.2 : Providing and applying spray painting in two coats (excluding priming
coat ) over concrete / masonry / asbestos cement sheet / plastered surfaces with flat wall
paint of approved brand to give even shade after cleaning the surface of all dirt, dust and Sqm 66.00
other foreign matter, and sand papering including cost of materials, labour, complete as per
specifications.
15.82 KSRB 15-19.3 : Providing and applying spray painting in one coat(excluding priming coat )
over concrete / masonry / asbestos cement sheet / plastered surfaces with flat wall paint of
approved brand to give even shade after cleaning the surface of all dirt, dust and other
foreign matter, and sand papering including cost of materials, labour, complete as per Sqm 42.00
specifications.

15.83 KSRB 15-20.1 : Providing and applying floor painting with ready mix paint in two coats
( exluding priming coat ) on new concrete / asbestos cement sheet / plastered surfaces
brushing to give an even shade after preparing the surface after throughly cleaning oil, dirt, Sqm 50.00
dust other foreign matter and sand papering including cost of materials, labour, complete as
per specifications.
15.84 KSRB 15-20.2 : Providing and applying floor painting with ready mix paint in one coat
( exluding priming coat ) on new concrete / asbestos cement sheet / plastered surfaces
brushing to give an even shade after preparing the surface after throughly cleaning oil, dirt, Sqm 32.00
dust other foreign matter and sand papering including cost of materials, labour, complete as
per specifications.
15.85 KSRB 15-21.1 : Providing and applying wax polish on new concrete floor and vertical
plastered surface using approved brand to give an even shade after preparing the surface
after thoroughly cleaning oil, dirt, dust other foreign matter, including cost of materials, Sqm 28.00
labour, complete as per specifications.
15.86 KSRB 15-21.2 : Providing and applying wax polish on new concrete floor and vertical
plastered surface using approved brand to give an even shade after preparing the surface
after thoroughly cleaning oil, dirt, dust other foreign matter, including cost of materials, Sqm 27.00
labour, complete as per specifications. previously polished concrete floor
15.87 KSRB 15-22.1 : Providing marble chips skirting or dado ( upto 30cms height ) rubbed and
polished to granolithic finish, top layer 6mm thick with white, black, chocolate, grey, yellow
or baroda green marble chips from smallest to 4mm nominal size dark shade pigment with
ordinary cement ( in top layer only ) laid in cement marble powder 3:1 ( 3 cement : 1 marble
powder by weight ) in proportion of 4:7 (4 cement marble powder mix : 7 marble chips by Sqm 1075.00
volume ) overall thickness 24mm (18mm thick under layer, 6mm thick top layer ) in cement
mortar of mix 1:3 including cost of materials, labour, complete as per specifications.

Page 97 of 350
15.88 KSRB 15-22.2 : Providing marble chips skirting or dado ( upto 30cms height ) rubbed and
polished to granolithic finish, top layer 6mm thick, with white, black, chocolate, grey,
yellow or baroda green marble chips from smallest to 4mm nominal size, light shade
pigment with white cement ( in top layer only ) laid in cement marble powder 3:1 ( 3 cement
: 1 marble powder by weight ) in proportion of 4:7 ( 4 cement marble powder mix : 7 marble Sqm 1125.00
chips by volume ) overall thickness 24mm (18mm thick under layer, 6mm thick top layer )
in cement mortar of mix 1:3 including cost of materials, labour, complete as per
specifications.

Page No. 122


15.89 KSRB 15-22.3 : Providing marble chips skirting or dado ( upto 30cms height ) rubbed and
polished to granolithic finish top layer 6mm thick with white, black, chocolate, grey, yellow
or baroda green marble chips from smallest to 4mm nominal size, medium shade pigment
with approximately 50% white cement and 50% ordinary cement (in top layer only ) laid in
cement marble powder 3:1 ( 3 cement :1 marble powder by weight ) in proportion of 4:7 ( 4 Sqm 1110.00
cement marble powder mix : 7marble chips by volume) overall thickness 24mm ( 18mm
thick under layer, 6mm thick top layer ) in cement mortar of mix 1:3 including cost of
materials, labour, complete as per specifications.

15.90 KSRB 15-22.4 : Providing marble chips skirting or dado ( upto 30cms height ) rubbed and
polished to granolithic finish top layer 6mm thick with white, black, chocolate, grey, yellow
or baroda green marble chips from smallest to 4mm nominal size, white cement without any
pigment ( in top layer only ) laid in cement marble powder 3:1 ( 3 cement : 1 marble powder
by weight ) in proportion of 4:7 ( 4 cement marble powder mix : 7 marble chips by volume ) Sqm 1060.00
overall thickness 24mm (18mm thick under layer, 6mm thick top layer ) in cement mortar of
mix 1:3 including cost of materials, labour, complete as per specifications.

15.91 KSRB 15-22.5 : Extra labour for work in dado exceeding 30 cms in height including cost of
Sqm 19.00
labour, complete as per specifications.
15.92 KSRB 15-23.1 : Providing pre-cast grey colour mosaic tiles 20mm thick with marble chips
of white, black, chocolate, grey, yellow or baroda green from smallest to 6mm nominal size,
with ordinary cement ( in top layer only ) for skirting and rises of steps ( not exceeding
30cms height) on 10cms thick cement mortar 1:3 jointed with neat cement slurry, rubbed m 274.00
and polished to granolithic finish, including cost of materials, labour, complete as per
specifications.

15.93 KSRB 15-23.2 : Providing pre-cast mosaic tiles using light shade pigment with white
cement 20mm thick with marble chips of white, black, chocolate, grey, yellow or baroda
green from smallest to 6mm nominal size, with ordinary cement ( in top layer only ) for
skirting and rises of steps ( not exceeding 30cms height ) on 10cms thick cement mortar 1:3 m 335.00
jointed with neat cement slurry, rubbed and polished to granolithic finish, including cost of
materials, labour, complete as per specifications.

15.94 KSRB 15-23.3 : Providing pre-cast mosaic tiles using medium shade pigment using
approximately 50% white cement and 50% ordinary cement 20mm thick with marble chips
of white, black, chocolate, grey, yellow or baroda green from smallest to 6mm nominal size,
with ordinary cement ( in top layer only ) for skirting and rises of steps ( not exceeding m 289.00
30cms height ) on 10cms thick cement mortar 1:3 jointed with neat cement slurry, rubbed
and polished to granolithic finish, including cost of materials, labour, complete as per
specifications.

Page No. 123


15.95 KSRB 15-23.4 : Providing pre-cast mosaic tiles of white shade with white cement without
any pigment 20mm thick with marble chips of white, black, chocolate, grey, yellow or
baroda green from smallest to 6mm nominal size, with ordinary cement ( in top layer only )
for skirting and rises of steps ( not exceeding 30cms height ) on 10cms thick cement mortar m 238.00
1:3 jointed with neat cement slurry, rubbed and polished to granolithic finish, including cost
of materials, labour, complete as per specifications.

15.96 Providing melamine polishing of approved shade including removing and refixing of doors
shutters scraping with blade and rubbing with zero size sand paper and applying sealer coat
by way of spraying with necessary compressor and applying patty after rubbing with steel Sqm 721.00
wool including two coats of approved shade of melamine polish etc., complete.

Page 98 of 350
15.97 Providing melamine polishing of approved shade including removing and refixing of doors
shutters, glass, beading and existing polishing, scraping with blade and rubbing with zero
size sand paper and applying sealer coat by way of spraying with necessary compressor and Sqm 907.00
applying patty after rubbing with steel wool including two coats of approved shade of
melamine polish etc., complete.
15.98.1 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament polyster fibers
6mm in cut length for use as micro reinforcement for application at 125 grams per bag of
cement I.e 0.25% by weight of cement. - for CM 1:4, 20mm thick Sqm 5.50

15.98.2 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament polyster fibers
6mm in cut length for use as micro reinforcement for application at 125 grams per bag of
cement I.e 0.25% by weight of cement. - for CM 1:4, 12mm thick Sqm 4.50

15.98.3 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament polyster fibers
6mm in cut length for use as micro reinforcement for application at 125 grams per bag of
cement I.e 0.25% by weight of cement. - for CM 1:6, 20mm thick Sqm 4.00

15.98.4 Providing and mixing Synthetic fibers 100% Virgin triangular monofilament polyster fibers
6mm in cut length for use as micro reinforcement for application at 125 grams per bag of
cement I.e 0.25% by weight of cement. - for CM 1:6, 12mm thick Sqm 3.50

15.99 Providing and mixing Synthetic fiber 100% virgin triangular monofilament polyester fibers
for use as micro secondary reinforcement in guitie and shotcrete civil works with application
dosage of 125-175 grams per bag of cement i.e. 0.25%-0.30% by weight of cement. Sqm 11.50

15.100. Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin polypropylene
1 fibers contains no olefin materials and are specially engineered manufactured to use as
cementitious micro reinforcement. Application @125 gms for 1:3 cement mortar, 150 gms
for 1:4 CM and 200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 24.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm long fibers shall
be used in the top coat. Fibermesh Harbourite fibers should be confirming to ASTM C 1116
ACI 524-93. - for CM 1:3 , 20mm thick

15.100. Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin polypropylene
2 fibers contains no olefin materials and are specially engineered manufactured to use as
cementitious micro reinforcement. Application @125 gms for 1:3 cement mortar, 150 gms
for 1:4 CM and 200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 15.50
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm long fibers shall
be used in the top coat. Fibermesh Harbourite fibers should be confirming to ASTM C 1116
ACI 524-93. - for CM 1:3 , 12mm thick

Page No. 124


15.100. Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin polypropylene
3 fibers contains no olefin materials and are specially engineered manufactured to use as
cementitious micro reinforcement. Application @125 gms for 1:3 cement mortar, 150 gms
for 1:4 CM and 200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 22.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm long fibers shall
be used in the top coat. Fibermesh Harbourite fibers should be confirming to ASTM C 1116
ACI 524-93. - for CM 1:4 , 20mm thick

15.100. Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin polypropylene
4 fibers contains no olefin materials and are specially engineered manufactured to use as
cementitious micro reinforcement. Application @125 gms for 1:3 cement mortar, 150 gms
for 1:4 CM and 200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 14.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm long fibers shall
be used in the top coat. Fibermesh Harbourite fibers should be confirming to ASTM C 1116
ACI 524-93. - for CM 1:4 , 12mm thick

Page 99 of 350
15.100. Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin polypropylene
5 fibers contains no olefin materials and are specially engineered manufactured to use as
cementitious micro reinforcement. Application @125 gms for 1:3 cement mortar, 150 gms
for 1:4 CM and 200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 19.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm long fibers shall
be used in the top coat. Fibermesh Harbourite fibers should be confirming to ASTM C 1116
ACI 524-93. - for CM 1:6 , 20mm thick

15.100. Providing and mixing fiber mesh Harbourite fine fibrillated 100% virgin polypropylene
6 fibers contains no olefin materials and are specially engineered manufactured to use as
cementitious micro reinforcement. Application @125 gms for 1:3 cement mortar, 150 gms
for 1:4 CM and 200 gms for 1:6 CM mix per bag of cement in both coats of the plaster. Sqm 14.00
Harbourite 12mm long shall be used in the back coat and Harbourite 6 mm long fibers shall
be used in the top coat. Fibermesh Harbourite fibers should be confirming to ASTM C 1116
ACI 524-93. - for CM 1:6, 12mm thick

15.101. Providing and mixing fibermesh stealth micro blocker anti microbial multi filament 100%
1 virgin polypropylene fibers which should be free from reprocessed olefin materials,
containing an active anti microbial ingredient built in to the polymer structure of the fiber
itself during manufacturing process.It should prevent the growth of micro organisms like
bacteria, mold fungus, mildew etc. on concrete surfaces. Application top of plaster to be
Sqm 39.50
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM 1:3, 175 gm for
CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro blocker shall confirm to ASTM C-
1116 type 111 4.1.3. - for CM 1:3, 20mm thick

15.101. Providing and mixing fibermesh stealth micro blocker anti microbial multi filament 100%
2 virgin polypropylene fibers which should be free from reprocessed olefin materials,
containing an active anti microbial ingredient built in to the polymer structure of the fiber
itself during manufacturing process.It should prevent the growth of micro organisms like
bacteria, mold fungus, mildew etc. on concrete surfaces. Application top of plaster to be
Sqm 26.50
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM 1:3, 175 gm for
CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro blocker shall confirm to ASTM C-
1116 type 111 4.1.3. - for CM 1:3, 12mm thick

15.101. Providing and mixing fibermesh stealth micro blocker anti microbial multi filament 100%
3 virgin polypropylene fibers which should be free from reprocessed olefin materials,
containing an active anti microbial ingredient built in to the polymer structure of the fiber
itself during manufacturing process.It should prevent the growth of micro organisms like
bacteria, mold fungus, mildew etc. on concrete surfaces. Application top of plaster to be
Sqm 35.50
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM 1:3, 175 gm for
CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro blocker shall confirm to ASTM C-
1116 type 111 4.1.3. - for CM 1:4, 20mm thick

15.101. Providing and mixing fibermesh stealth micro blocker anti microbial multi filament 100%
4 virgin polypropylene fibers which should be free from reprocessed olefin materials,
containing an active anti microbial ingredient built in to the polymer structure of the fiber
itself during manufacturing process.It should prevent the growth of micro organisms like
bacteria, mold fungus, mildew etc. on concrete surfaces. Application top of plaster to be
Sqm 22.50
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM 1:3, 175 gm for
CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro blocker shall confirm to ASTM C-
1116 type 111 4.1.3. - for CM 1:4, 12mm thick

15.101. Providing and mixing fibermesh stealth micro blocker anti microbial multi filament 100%
5 virgin polypropylene fibers which should be free from reprocessed olefin materials,
containing an active anti microbial ingredient built in to the polymer structure of the fiber
itself during manufacturing process.It should prevent the growth of micro organisms like
bacteria, mold fungus, mildew etc. on concrete surfaces. Application top of plaster to be
Sqm 33.50
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM 1:3, 175 gm for
CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro blocker shall confirm to ASTM C-
1116 type 111 4.1.3. - for CM 1:6, 20mm thick

Page 100 of 350


15.101. Providing and mixing fibermesh stealth micro blocker anti microbial multi filament 100%
6 virgin polypropylene fibers which should be free from reprocessed olefin materials,
containing an active anti microbial ingredient built in to the polymer structure of the fiber
itself during manufacturing process.It should prevent the growth of micro organisms like
bacteria, mold fungus, mildew etc. on concrete surfaces. Application top of plaster to be
Sqm 29.50
mixed in mechanical mixer at 150 gm of fibers per bag of cement for CM 1:3, 175 gm for
CM 1:4 and 250 gms for CM 1:6 fibermesh stealth micro blocker shall confirm to ASTM C-
1116 type 111 4.1.3. - for CM 1:6, 12mm thick

15.102. Providing and mixing Harbourite 12 mm fine fibrillated 100% virgin polypropylene fibers
which should be free from reprocessed olefin materials and specifically manufactured for use
as cementitious micro reinforcement application rate of 175 gms to 250 gms per bag of Sqm 68.00
cement or 1.8 kg per cum in the guinite/shotcret and designed to an optimum gradation for
use as concrete secondary reinforcement.
15.103. Providing external walls with texture finish using approved brand paint, applied uniformly in
three coats over one coat of primer including cost of all materials, machineries, labour,
transportation, loading and unloading, all lead and lift and all other incidental charges Sqm 288.00
including scaffolding and removing stains, complete as per specifications.

15.104. Providing and finishing external walls in two coats over one coat of primer with antifungal
paint of approved brand and shade to give an even shade after thoroughly brooming the
surface to remove all dirt and loose powdered material, free from mortar drops and other Sqm 151.00
foreign matter cost of materials, labour, complete as per specifications. (P.No. 124, I.No.
15.104 of CSR 2015-16).
15.105. Providing textured paint of approved quality, colour and shade to wall surface after cleaning
and rubbing the wall surface with wire brush of medium size emery stone to remove all the
loosely adhering particles, the surface is then cleaned with water and ensured that it is in line
and level. The textured material is then mixed with 40-50% of clean water until a
homogeneous thick slurry is formed, the slurry is left for 5-10 min, to react completely with
ingredients. The textured finish prepared as above is then applied to the wall surface with
suitable roller/spray gun/putty/ blade/ trowel to get the desired finish. The finished surface Sqm 348.00
shall be applied with two coats of exterior apex paint of approved shade. The rate includes
providing and removing scaffolding, all lead and lift and all other incidental charges etc.,
complete as per directions of the Engineer-in-charge of the work.

Page No. 126


15.106. Providing applying two coats of wall putty to inside plastered walls and ceiling using white
cement putty. Scrapping and levelling the surface using steel blade and preparing the surface
even and smooth by using different grade sand papers, including cost of all materials, cost of Sqm 56.00
labour and scaffolding etc., complete as per the specification. (P.No. 125, I.No. 15.106 of
SR 2015-16).

16.0 16.REPAIRS TO BUILDINGS

16.1.1 KSRB 24-1 : Removing white wash or colour wash by steel brushing and / or scraping, sand
papering and preparing wall surface smooth including repairs to scraches, cost of labour,
complete as per specifications. Specification No.KBS. (P.No. 127/ I.No. 16.1.1 of CSR Sqm 6.00
2015-16)
16.1.2 KSRB 24-2 : Extra for removing white wash or colour wash by steel brushing and / or
scraping, sand papering the ceiling and / or sloping roof surface smooth including repairs to Sqm 6.00
scraches, cost of labour, complete as per specifications.
16.1.3 KSRB 24-3 : Extra for washing the wall surface spoiled by smoke, soot, with clear water
before sand papering the surface smooth including necessary repairs to scraches, cost of Sqm 3.00
labour, complete as per specifications.
16.1.4 KSRB 24-4 : Extra for Item No. 24-3 washing the ceiling and / or sloping roof surface
spoiled by smoke soot with clear water before sand papering the surface smooth and
including necessary repairs to scraches, cost of labour, complete as per specifications. Sqm 3.00

Page 101 of 350


16.2.1 KSRB 24-5 : Cleaning and washing of decorated wall surface with soap, soda and water
including cost of materials, labour, complete as per specifications. Specification No.KBS Sqm 3.00

16.2.2 KSRB 24-6 : Extra for KSRB 24-5 cleaning and washing the old ceiling and / or sloping
roof with soap, soda and water including cost of materials, labour, complete as per Sqm 3.00
specifications.
16.3.1 KSRB 24-7 : Cleaning and washing the old plastered wall surface with soap, soda, water
Sqm 3.00
including cost of materials, labour, complete as per specifications.
16.3.2 KSRB 24-8 : Extra for Item No. 24-7 cleaning and washing the old plastered ceiling and / or
sloping roof surface with soap, soda, water including cost of materials, labour, complete as Sqm 3.00
per specifications.
16.4 KSRB 24-9 : Cleaning and washing of stone masonry wall surface with nitric acid including
cost of materials, labour, complete as per specifications. Specification No.KBS Sqm 3.50

16.5 KSRB 24-10 : Removing the old paint or polish from wood and / or wood based surface
with paint remover of approved brand / manufacturer and making surface even including
cost of materials, labour, complete as per specifications. Specification No.KBS. (P. No. 127, Sqm 46.00
I.No. 16.5 of CSR 2015-16).
Page No. 128
16.6 KSRB 24-11 : Removing the old paint or polish from wood and / or wood based surface
with caustic soda solution and making surface even including cost of materials, labour, Sqm 30.00
complete as per specifications. Specification No.KBS
16.7 KSRB 24-12 : Removing the old paint from wood and / or wood based surface with blow
lamp and making surface even including cost of materials, labour, complete as per Sqm 62.00
specifications. Specification No.KBS
16.8 KSRB 24-13 : Removing the old paint from steel and / or other metal surface with hand
scraping and making surface even including cost of labour, complete as per specifications. Sqm 52.00
Specification No.KBS. (P. No. 128, I.No. 16.8 of CSR 2015-16).
16.9 KSRB 24-14 : Removing the old paint from steel and / or other metal surface with flame
cleaning and making surface even including cost of material, labour, complete as per Sqm 62.00
specifications. Specification No.KBS
16.10 KSRB 24-15 : Removing the old paint from steel and / or other metal surface with paint
remover of approved brand / manufacturer cleaning and making surface even including cost
of material, labour, complete as per specifications. Specification No.KBS Sqm 45.00

16.11 KSRB 24-16 : Fixing small pieces ( not exceeding 0.015 cum ) for making good wherever
hinges etc., have been removed from frames or joinery etc., with teak wood excluding cost
of materials but including cost of labour, complete as per specifications. Specification Piece 16.00
No.KBS
16.12 KSRB 24-17 : Providing and fixing small pieces ( not exceeding 0.015 cum ) for making
good wherever hinges etc., have been removed from frames or joinery etc., with honne wood
including cost of materials, labour, complete as per specifications. Specification No.KBS Piece 187.00

16.13 KSRB 24-18 :Providing and fixing small pieces ( not exceeding 0.015 cum ) for making
good wherever hinges etc., have been removed from frames or joinery etc., with matti /
nandi wood including cost of materials, labour, complete as per specifications. Specification Piece 156.00
No.KBS. (P.No. 128, I.No. 16.13 of SR 2015-16)
16.14 KSRB 24-19 : Providing and fixing small pieces ( not exceeding 0.015 cum ) for making
good wherever hinges etc., have been removed from frames or joinery etc., with Sal wood
pieces ( not exceeding 0.015 cum ) including cost of materials, labour, complete as per Piece 124.00
specifications. Specification No.KBS
16.15 KSRB 24-20 : Renewing bars, styles and rails, straight for joinery upto 50mm thick
including mitres, haunching, mortices etc., and removing the old defective pieces and
replacing with Teak wood including cost of materials, labour, complete as per specifications. Piece 990.00
Specification No.KBS
16.16 KSRB 24-21 :Renewing bars, styles and rails, straight for joinery upto 50mm thick including
mitres, haunching, mortices etc., and removing the old defective pieces and replacing with
Honne wood including cost of materials, labour, complete as per specifications. Piece 522.00
Specification No.KBS

Page 102 of 350


16.17 KSRB 24-22 : Renewing bars, styles and rails, straight for joinery upto 50mm thick
including mitres, haunching, mortices etc., and removing the old defective pieces and
replacing with Matti / Nandi woodincluding cost of materials, labour, complete as per Piece 438.00
specifications. Specification No.KBS
Page No. 129
16.18 KSRB 24-23 : Rewedging, cramping joinery of any description with new wedges in glue or
white lead and repinning including rehanging or refixing of shutters, hinges or pivots, not
exceeding one sqm per leaf, removing or dismantling excluding cost of wood but including Leaf 356.00
cost of labour, complete as per specifications. Specification No.KBS. (P.No. 129, I.No.
16.18 of SR 2015-16)

16.19 KSRB 24-24 :Rewedging, cramping joinery of any description with new wedges in glue or
white lead and repinning including rehanging or refixing of shutters, hinges or pivots, not
exceeding one sqm per leaf, removing or dismantling excluding cost of wood but including Leaf 472.00
cost of labour, complete as per specifications. Specification No.KBS exceeding one sqm but
not exceeding two sqm per leaf

16.20 KSRB 24-25 : Rewedging, cramping joinery of any description with new wedges in glue or
white lead and repinning including rehanging or refixing of shutters, hinges or pivots, not
exceeding one sqm per leaf, removing or dismantling excluding cost of wood but including Leaf 668.00
cost of labour, complete as per specifications. Specification No.KBS exceeding two sqm

16.21 KSRB 24-26 : Making repairs to joinery at angles with 300mm x 25mm x 3mm length of
MS flat forged to shape and let into wood work, counter sunk, drilled and screwed including
cost of materials, labour, complete as per specifications. Specification No.KBS Each 80.00

16.22 KSRB 24-27 : Renewing Honne wood battens in roof including making good the holes in
walls, removal of rubbish to the dumping round with a lead upto 50 m including cost of
materials, labour, complete as per specifications. Specification No.KBS cum 13288.00

16.23 KSRB 24-28 :Renewing Matti / Nandi wood battens in roof including making good the
holes in walls, removal of rubbish to the dumping round with a lead upto 50 m including
cost of materials, labour, complete as per specifications. Specification No.KBS cum 11053.00

16.24 KSRB 24-29 :Renewing Sal wood battens in roof including making good the holes in walls,
removal of rubbish to the dumping round with a lead upto 50 m including cost of materials, cum 9422.00
labour, complete as per specifications. Specification No.KBS
16.25 KSRB 24-30 : Removal of old broken glass panes (any thickness of size, quality or
description) from wooden frames, glazed with putty or fixed with beads including cost of Sqm 76.00
labour, complete as per specifications. Specification No.KBS
16.26 KSRB 24-31 : Removal of old broken glass panes (any thickness of size, quality or
description) from metal frames, glazed with putty or fixed with beads including cost of Sqm 108.00
labour, complete as per specifications. Specification No.KBS
16.27 KSRB 24-32 : Removing serviceable glass of any description from old wood or metal
frames (any thickness or size, quality or description) hacking out old putty etc., including
risk and making good breakages in taking out and handling, stacking within a lead of 50 m. Sqm 110.00
including cost of labour, complete as per specifications. Specification No.KBS. (P.No. 129,
I.No. 16.27 of SR 2015-16)

16.28 KSRB 24-33 : Supplying and fixing new teak wood beads wherever necessary including cost
of materials, labour, complete as per specifications. Specification No.KBS m 35.00

16.29 KSRB 24-34 : Supplying and fixing new Honne wood beads wherever necessary including
cost of materials, labour, complete as per specifications. Specification No.KBS m 24.00

16.30 KSRB 24-35 : Renewal of old putty of glass panes including cost of materials, labour,
m 25.00
complete as per specifications. Specification No.KBS 24.2.6
16.31 KSRB 24-36 : Removing the glazed tiles in patches in area exceeding 10 tiles and not
exceeding 5 sqm including removing old tiles preparing surfaces and laying or setting new
or old tiles complete including cost of materials, ( excluding cost of tiles ) labour, complete Sqm 551.00
as per specifications. Specification No.KBS

Page 103 of 350


Page No. 130
16.32 KSRB 24-37 : Removing the mosaic tiles in patches in area exceeding 10 tiles and not
exceeding 5 sqm including removing old tiles preparing surfaces and laying or setting new
or old tiles complete including cost of materials, ( excluding cost of tiles ) labour, complete Sqm 437.00
as per specifications. Specification No.KBS
16.33 KSRB 24-38 : Cutting out cracks of roof terrace to V - section cleaning out, wetting,
grouting with cement and sand slurry 1:3 (1 cement, 3 sand) including cost of materials, m 43.00
labour, complete as per specifications. Specification No.KBS
16.34 KSRB 24-39 : Cutting out cracks of roof terrace to V - section cleaning out and filling
solidly with a hot mixure of bitumen and clean dry sand 1:1 by weight including cost of Sqm 43.00
materials, labour, complete as per specifications. Specification No.KBS
16.35.1 KSRB 24-40 : Dubbing out on old irregular walls average 10mm thick and making good the
surface with cement mortar 1:3 including curing cost of materials, labour, complete as per Sqm 180.00
specifications. Specification No.KBS 24.2.1
16.35.2 KSRB 24-43 : Add from Item no. 24-40 for every 5mm thick increase after 10mm with
respective mortars including curing cost of materials, labour, complete as per specifications. Sqm 49.00

16.36.1 KSRB 24-41 : Dubbing out on old irregular walls average 10mm thick and making good the
surface with cement mortar 1:4 including curing cost of materials, labour, complete as per Sqm 156.00
specifications. Specification No.KBS 24.2.1
16.36.2 KSRB 24-43 : Add from Item no. 24-40, 24-41, 24-42 for every 5mm thick increase after
10mm with respective mortars including curing cost of materials, labour, complete as per Sqm 42.00
specifications.
16.37.1 KSRB 24-42 : Dubbing out on old irregular walls average 10mm thick and making good the
surface with cement mortar 1:6 including curing cost of materials, labour, complete as per Sqm 132.00
specifications. Specification No.KBS 24.2.1
16.37.2 KSRB 24-43 : Add from Item no. 24-40, 24-41, 24-42 for every 5mm thick increase after
10mm with respective mortars including curing cost of materials, labour, complete as per Sqm 37.00
specifications.
16.38 KSRB 24-44 : Repairs to plaster in patches of 2.5 sqm and less in walls, ceilings 10 to
20mm thick in cement mortar 1:3 including cutting the patches in proper shape and
replastering the surface of the wall including disposal of rubbish with a lead of 50m Sqm 256.00
including curing cost of materials, labour, complete as per specifications. Specification
No.KBS 24.2.1 (P.No. 130, I.No. 16.38 of SR 2015-16).
16.39 KSRB 24-45 : Repairs to plaster in patches of 2.5 sqm and less in walls, ceilings 10 to
20mm thick in cement mortar 1:4 including cutting the patches in proper shape and
replastering the surface of the wall including disposal of rubbish with a lead of 50m Sqm 232.00
including curing cost of materials, labour, complete as per specifications. Specification
No.KBS 24.2.1 (P.No. 130, I.No. 16.39 of SR 2015-16).
16.40 KSRB 24-46 : Repairs to plaster in patches of 2.5 sqm and less in walls, ceilings 10 to
20mm thick in cement mortar 1:6 including cutting the patches in proper shape and
replastering the surface of the wall including disposal of rubbish with a lead of 50m Sqm 209.00
including curing cost of materials, labour, complete as per specifications. Specification
No.KBS 24.2.1
16.41 Removing of existing old or broken wash basin / urinals and disposing it with all cost and
conveyance labour for all items of work, HOM of equipment with all lead and lift, loading
and unloading, transportation charges and all other incidental charges etc., complete as per Each 203.00
specification and directions of the Engineer-in-charge of the work.
Page No. 131
16.42 Removing of existing old or broken Water closet Indian / Eurpoean and disposing it with all
cost and conveyance labour for all items of work, HOM of equipment with all lead and lift,
loading and unloading, transportation charges and all other incidental charges etc., complete Each 187.00
as per specification and directions of the Engineer-in-charge of the work.

16.43 Removing of existing old Sanitary and plumbing pipelines, stacking and disposing it with all
cost and conveyance labour for all items of work, HOM of equipment with all lead and lift,
loading and unloading, transportation charges and all other incidental charges etc., complete m 62.00
as per specification and directions of the Engineer-in-charge of the work.

Page 104 of 350


16.44 External sweeping and terrace cleaning - Cleaning of outer periphery like roads footpaths
curb stones terrace including removing grass dust etc., to the nearest garbage pit using
suitable coconut broomstic,bombay broomstick, squezers /wipers / rubberbrushes, coir Sqm 0.50
brushes, bamboo baskets, plastic bukets mugs trolley etc., complete

16.45 Cleaning stone parapets removing of dirt dust etc., using suitrable soap powder, coconut
broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes, mugs, booster
pumps with portable arrangement, hose pipe etc., complete including cost of water charges Sqm 1.00
and electrical charges.
16.46 Cleaning Quadrangle chajjas including removing of dirt dust etc., using suitrable soap
powder , coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric
brushjes, mugs, booster pumps with portable arrangement, hose pipe etc., complete Sqm 7.00
excluding water charges including electrical charges and all safety measures.

16.47 Cleaning sub surface drains including removing of dirt dust etc., using suitrable soap powder
, coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes,
mugs, booster pumps with portable arrangement, hose pipe etc., complete m 10.00

16.48 Cleaning surface drains including removing of dirt dust etc., using suitrable soap powder ,
coconut broomstick, squeezers / wipers/ rubber brushes, coir brushes, plastric brushjes,
mugs, booster pumps with portable arrangement, hose pipe etc., complete. m 6.00

16.49 Cleaning of office floors, toilet floors, corridors, lobbies, partitions, storage units,
furnitures,electrical & electronic equipments, doors, windows, curtains, blinds etc., including
cleaning of dust, etc., using suitable bombay broom stick, squezers / wipers/rubber brushes,
mop sticks, coir brushes, bamboo baskets, plastic buckets, trolleys, wiping cloths, carry Sqm 1.50
bags, etc.,removing the debris to the nearest garbage pit complete.

Page No. 132

17.0 17.ROADS AND BRIDGES - CARRIAGE OF MATERIALS

17.1 KSRRB M100-1 Loading and Unloading of Stone Boulder / Stone aggregates /Sand/ Kanker
/ Moorum. KSRRB M100-1 : Placing tipper at loading point, loading with front end
loader,dumping, turning for return trip, excluding time for haulage and return trip complete cum 68.00
as per specifications. MORTH -100/ Chapter 1
17.2 KSRRB M100-2. Loading and Unloading of Stone Boulders by Manual Means complete as
cum 88.00
per specifications. MORTH -100/ Chapter 1
17.3 KSRRB M100-3 Loading and Unloading of Cement or Steel by Manual Means and as per
Tonne 122.00
specifications complete MORTH -100/ Chapter 1
17.4 KSRRB M100-4.1. Cost of Haulage Excluding Loading and Unloading MORTH -100/
t.km 2.50
Chapter 1 Case-I : Surface Road
17.5 KSRRB M100-4.2. Haulage of materials by tipper excluding cost of loading, unloading and
stacking complete as per specifications. MORTH -100/ Chapter 1 Case-II : Unsurfaced t.km 2.60
Gravelled Road
17.6 KSRRB M100-4.3. Haulage of materials by tipper excluding cost of loading, unloading and
stacking complete as per specifications.MORTH Chapter 1 Case-III : Katcha Track and t.km 4.85
Track in River Bed/Nallah Bed and Choe Bed
17.7 KSRRB M100-5. Supply of quarried stone, hand breaking into coarse aggregate 63mm
nominal size (passing 80 mm and retained on 50 mm sieve) and stacking as directed cum 689.00
complete as per specifications. MORTH -100/ Chapter 1
17.8 KSRRB M100-6. Crushing of stone boulders of 150 mm size in an integrated stone crushing
unit of 200 tonnes per hour capacity comprising of primary and secondary crushing units,
belt conveyor and vibrating screens to obtain stone aggregates of 13.2 mm nominal size cum 896.00
complete. MORTH -100/ Chapter 1
17.9 KSRRB M100-7. Crushing of stone boulders of 150 mm size in an integrated stone crushing
unit of 200 tonnes per hour capacity comprising of primary and secondary crushing units,
belt conveyor and vibrating screens to obtain stone aggregates of 20 mm nominal size cum 901.00
complete. MORTH -100/ Chapter 1

Page 105 of 350


17.10 KSRRB M100-8. Crushing of stone boulders of 150 mm size in an integrated stone crushing
unit of 200 tonnes per hour capacity comprising of primary and secondary crushing units,
belt conveyor and vibrating screens to obtain stone aggregates of 40mm nominal size cum 805.00
complete. MORTH -100/ Chapter 1
Page No. 134

18.0 18.SITE CLEARANCE AND DISMANTLING

18.1 KSRRB 200-1. Cutting of trees girth from 300mm to 600mm including cutting of trunks,
branches and removal of stumps stacking of serviceable materials earth filling in the
depressions / pit, labour charges complete as per specifications. MORTH specification Each 189.00
clause 201/ Chapter 2
18.2 KSRRB 200-2. Cutting of trees girth from 600mm to 900mm including cutting of trunks,
branches and removal of stumps stacking of serviceable materials earth filling in the
depressions / pit, labour charges complete as per specifications. MORTH specification Each 583.00
clause 201/ Chapter 2
18.3 KSRRB 200-3. Cutting of trees girth from 900mm to 1800mm including cutting of trunks,
branches and removal of stumps stacking of serviceable materials earth filling in the
depressions / pit, labour charges complete as per specifications. MORTH specification Each 1417.00
clause 201/ Chapter 2
18.4 KSRRB 200-4. Cutting of trees girth from 1800mm to 2700mm including cutting of trunks,
branches and removal of stumps stacking of serviceable materials earth filling in the
depressions / pit, labour charges complete as per specifications. MORTH specification Each 2205.00
clause 201/ Chapter 2
18.5 KSRRB 200-5. Cutting of trees girth from 2700mmto 3600mm including cutting of trunks,
branches and removal of stumps stacking of serviceable materials earth filling in the
depressions / pit, labour charges complete as per specifications. MORTH specification Each 4410.00
clause 201/ Chapter 2
18.6 KSRRB M200-6.1 Cutting of trees girth from 300mm to 600mm including cutting of trunks,
branches and removal of stumps stacking of serviceable materials with all lifts earth filling
in the depressions / pit, complete as per specifications. MORTH Specification No. 201 Each 364.00

18.7 KSRRB M200-6.2 Cutting of trees girth from 600mm to 900mm including cutting of trunks,
branches and removal of stumps stacking of serviceable materials with all lifts earth filling
in the depressions / pit, complete as per specifications. MORTH Specification No. 201 Each 703.00

18.8 KSRRB M200-6.3 Cutting of trees girth from 900mm to 1800mm including cutting of
trunks, branches and removal of stumps stacking of serviceable materials with all lifts earth
filling in the depressions / pit, complete as per specifications. MORTH Specification No. Each 1542.00
201
18.9 KSRRB M200-6.4 Cutting of trees girth from 1800mm to 2700mm including cutting of
trunks, branches and removal of stumps stacking of serviceable materials with all lifts earth
filling in the depressions / pit, complete as per specifications. MORTH Specification No. Each 2075.00
201
18.9.1 KSRRB M200-6.4 Cutting of trees girth from 2700mm to 3600mm including cutting of
trunks, branches and removal of stumps stacking of serviceable materials with all lifts earth
filling in the depressions / pit, complete as per specifications. MORTH Specification No. Each 4598.00
201
18.10 KSRRB M200-7.1. Clearing grass and removal of rubbish by manual means and stacking
outside the periphery of the area cleaned complete as per specifications. MORTH Ha 16217.00
Specification No. 201
18.11 KSRRB 200-8. Clearing and grubbing road land including uprooting rank vegetation, grass,
brush, shrubs, saplings and trees of girth upto 300mm, by manual means, in area of light
jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable Sqm 6.00
materials labour charges complete as per specifications. MORTH / Chapter 2

Page 106 of 350


18.12 KSRRB 200-9. Clearing and grubbing road land including uprooting rank vegetation, grass,
brush, shrubs, saplings and trees of girth upto 300mm, by manual means, in area of thorney
jungle, removal of stumps, disposal of unserviceable materials, stacking of serviceable Sqm 9.00
materials labour charges complete as per specifications. MORTH / Chapter 2

18.13 KSRRB M200-10.1. Clearing and grubbing road land including uprooting rank vegetation,
grass, bushes, shrubs, saplings and trees girth up to 300 mm, removaL of stumps of trees cut
earlier and disposal of unserviceable materials and stacking of serviceable material to be
used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm Ha 48878.00
in thickness complete as per specifications. I. By Manual Means: A. In area of light jungle.
MORTH Specification No. 201

18.14 KSRRB M200-10.2. Clearing and grubbing road land including uprooting rank vegetation,
grass, bushes, shrubs, saplings and trees girth up to 300 mm, removaL of stumps of trees cut
earlier and disposal of unserviceable materials and stacking of serviceable material to be
used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm Ha 65322.00
in thickness complete as per specifications. I. By Manual Means:B. In area of thorny jungle.

Page No. 136


18.15 KSRRB M200-11.1. Clearing and grubbing road land including uprooting rank vegetation,
grass, bushes, shrubs, saplings and trees girth up to 300 mm, removalof stumps of trees cut
earlier and disposal of unserviceable materials and stacking of serviceable material to be
used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm Ha 20725.00
in thickness complete as per specifications . II. By Mechanical Means:A. In area of light
jungle. MORTH Specification No. 201

18.16 KSRRB M200-11.2. Clearing and grubbing road land including uprooting rank vegetation,
grass, bushes, shrubs, saplings and trees girth up to 300 mm, removalof stumps of trees cut
earlier and disposal of unserviceable materials and stacking of serviceable material to be
used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm Ha 25328.00
in thickness complete as per specifications .II. By Mechanical Means:B. In area of thorny
jungle

18.17 KSRRB M200-12.1. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 309.00
specifications. i) Lime /Cement Concrete. I. By Manual Means :A. Lime Concrete, cement
concrete grade M-10 and below. MORTH Specification No. 202. (P.No. 136/ I. No. 18.17 of
CSR 2015-16)

18.18 KSRRB M200-12.2. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 374.00
specifications. i) Lime /Cement Concrete. I. By Manual Means :B. Cement Concrete Grade
M-15 & M-20. MORTH Specification No. 202. (P.No. 136, I.No. 18.18 of CSR 2015-16)

18.19 KSRRB M200-12.3. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 1022.00
specifications. C. Prestressed / Reinforced cement concrete grade M-20 & above. MORTH
Specification No. 202

18.20 KSRRB M200-13.1. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 345.00
specifications. II. By Mechanical Means. A. Cement Concrete Grade M-15 &M-20.
MORTH Specification No. 202

Page 107 of 350


18.21 KSRRB M200-13.2. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 601.00
specifications. II.By Mechanical Means. MORTH Specification No. 202

18.22 KSRRB M200-14.1. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 179.00
specifications. ii) Dismantling Brick / Tile work. A. In lime mortar. MORTH Specification
No. 202

18.23 KSRRB M200-14.2. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 244.00
specifications. ii) Dismantling brick/Tile work B. In cement mortar. MORTH Specification
No. 202

18.24 KSRRB M200-14.3. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 153.00
specifications. ii) Dismantling brick/Tile work C. In mud mortar.MORTH Specification No.
202

18.25 KSRRB M200-14.4. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 140.00
specifications. ii) Dismantling brick/Tile work D. Dry brick pitching or brick soling.
MORTH Specification No. 202

18.26 KSRRB M200-15.1. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 205.00
specifications. iii) Dismantling Stone Masonry. A. Rubble Stone masonry in lime mortar.
MORTH Specification No. 202

Page No. 137


18.27 KSRRB M200-15.2. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 244.00
specifications. iii) Dismantling Stone Masonry.B. Rubble stone masonry in cement mortar.
MORTH Specification No. 202

18.28 KSRRB M200-15.3. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 179.00
specifications. iii) Dismantling Stone Masonry C. Rubble stone masonry in mud mortar.
MORTH Specification No. 202

18.29 KSRRB M200-15.4. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 166.00
specifications. iii) Dismantling Stone Masonry D. Dry rubble masonry. MORTH
Specification No. 202

Page 108 of 350


18.30 KSRRB M200-15.5. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 153.00
specifications. iii) Dismantling Stone MasonryE. Dismantling stone pitching / dry stone
spalls. MORTH Specification No. 202

18.31 KSRRB M200-15.6.Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 179.00
specifications. Dismantling brick/Tile work F. Dismantling Boulders laid in wire crates
including opening of crates and stacking dismantled materials.

18.32 KSRRB M200-16.Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 438.00
specifications. iv) Dismantling wood work wrought framed and fixed in frames of trusses
upto a Height of 5m above Plinth Level.

18.33 “KSRRB M200-17.1. Dismantling of existing structures like culverts, bridges, retaining
walls and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per Tonne 1202.00
specifications. v) Steel work in all types of Sections upto a Height of 5 m above plinth level
excluding Cutting of Rivet. – A. Including dismembering.” (P.No.137/ I.No. 18.33 of CSR
2015-16)

18.34 KSRRB M200-17.2. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per Tonne 908.00
specifications. v)Steel work in all types of Sections upto a Height of 5 m above plinth level
excluding Cutting of Rivet– B. Excluding dismembering.

18.35 Dismantling of existing structures like culverts, bridges, retaining walls and other structure
comprising of masonry, cement concrete, wood work, steel work, including T&P and
scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable RIVE 8.00
material and stacking the serviceable material with all lifts complete as per specifications. B T
for cutting rivets.
18.36 KSRRB M200-18.1. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per Nos 1.00
specifications. vi) Scraping of Bricks Dismantled from Brick work including Stacking - A.
In Lime / Cement mortar.

18.37 KSRRB M200-18.2. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal Nos 0.50
of unserviceable material and stacking the serviceable material with all lifts complete as per
specifications. B. In mud mortar.
18.38 KSRRB M200-19.1. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per cum 455.00
specifications. vii) Scraping of stones from dismantled stone masonry – A. In cement and
lime mortar.

Page 109 of 350


18.39 KSRRB M200-19.2.Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal cum 97.00
of unserviceable material and stacking the serviceable material with all lifts complete as per
specifications. B. In mud mortar.
18.40 KSRRB M200-20.Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per Sqm 14.00
specifications. viii) Scraping plaster in lime or cement mortar from brick / stone masonry.

18.41 KSRRB M200-21.1. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per m 168.00
specifications. ix) Removal of all types of Hume pipes and stacking including earthwork
and dismantling of masonry works – A. Upto 600 mm dia

18.42 KSRRB M200-21.2. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per m 228.00
specifications. Removal of all types of Hume pipes and stacking including earthwork and
dismantling of masonry works – B. Above 600 mm to 900 mm dia.

18.43 KSRRB M200-21.3. Dismantling of existing structures like culverts, bridges, retaining walls
and other structure comprising of masonry, cement concrete, wood work, steel work,
including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal
of unserviceable material and stacking the serviceable material with all lifts complete as per m 390.00
specifications. Removal of all types of Hume pipes and stacking including earthwork and
dismantling of masonry works C. Above 900 mm dia.

18.47 KSRRB M200-24. Dismantling of cement concrete pavement by mechanical means using
pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at
designated locations and disposal of dismantled materials stacking serviceable and cum 781.00
unserviceable materials seperately complete as per specifications. MORTH Specification
No. 202
18.48 KSRRB M200-25. Dismantling of guard rails by manual means and disposal of dismantled
materials with all lifts and stacking serviceable materials and unserviceable materials
seperately complete as per specifications. MORTH Specification No. 202 m 60.00

Page No. 138


18.49 KSRRB M200-26. Dismantling Kerb stone by manual means and disposal of dismantled
materials with all lifts and complete as per specifications. MORTH Specification No. 202 m 10.00

18.50 KSRRB M200-27. Dismantling of Kerb stone channel by manual means including and
disposal of dismantled material with all lifts and complete as per specifications. MORTH m 14.00
Specification No. 202
18.51 KSRRB M200-28.1. Dismantling of kilometre stone including cutting of earth, foundation
and disposal of dismantled material with all lifts and back filling of pit complete as per
specifications. A. 5th KM stone ( quantity of cement concrete = 0.392 cum). MORTH Each 309.00
Specification No. 202
18.52 KSRRB M200-28.2.Dismantling of kilometre stone including cutting of earth, foundation
and disposal of dismantled material with all lifts and back filling of pit complete as per
specifications B. Ordinary KM stone ( quantity of cement concrete = 0.269 cum ). Each 185.00

Page 110 of 350


18.53 KSRRB M200-28.3. Dismantling of kilometre stone including cutting of earth, foundation
and disposal of dismantled material with all lifts and back filling of pit complete as per
specifications C. Hectometer stone ( quantity of cement concrete = 0.048 cum ]. Each 37.00

18.54 KSRRB M200-29. Dismantling of barbed wire fencing / wire mesh fencing including posts,
foundation concrete, back filling of pit by manual means including disposal of dismantled
material with all lifts and stacking serviceable material and unserviceable material separately m 42.00
complete as per specifications. MORTH Specification No. 202
18.55 KSRRB M200-30. Dismantling of CI water pipe line 600 mm dia including disposal with all
lifts and stacking of serviceable material and unserviceable material separately under
supervision of concerned department complete as per specifications. MORTH Specification m 97.00
No. 202
18.56 KSRRB M200-31. Removal of cement concrete pipe of sewer gutter 1500 mm dia under the
supervision of concerned department including disposal with all lifts and stacking of
serviceable and unserviceable material separately but excluding earth excavation and m 128.00
dismantling of masonry works complete as per specifications. MORTH Specification No.
202
18.57 KSRRB M200-32. Removal of Telephone / Electric poles including excavation and
dismantling of foundation concrete and lines under the supervision of concerned department,
disposal with all lifts and stacking the serviceable and unserviceable material Nos 141.00
separatelycomplete as per specifications. MORTH Specification No. 202
Page No. 139

19.0 19.EARTH WORK, EROSION CONTROL AND DRAINAGE

19.1 KSRRB 300 - Excavation for road, drains and similar works KSRRB 300-1. Earthwork
excavation by manual means in ordinary soil involving an average horizontal throw upto 2
meters and an average lift upto 0.5 m, excavated surface leveled and sides neatly dressed, the cum 82.00
disposed earth to be leveled neatly after breaking of clods complete as per specifications.
MORTH / Chapter 3
19.2 KSRRB 300-2. Earthwork excavation by manual means in hard soil involving an average
horizontal throw upto 2 meters and an average lift upto 0.5 m, excavated surface leveled and
sides neatly dressed, the disposed earth to be leveled neatly after breaking of clods complete cum 113.00
as per specifications. MORTH / Chapter 3
19.3 KSRRB 300 - Excavation for road formation KSRRB 300-3. Earthwork excavation and
forming in embankment by manual means in ordinary soil (When earth is taken from bank
cutting or from borrow pits ) including breaking of clods, spreading to required line and
level, forming, and cost of all labour complete as per specifications. ( excluding watering cum 104.00
and compaction of earth ) (with all lead and lift) MORTH / Chapter 3

19.4 KSRRB 300-4. Earthwork excavation and forming in embankment by manual means in hard
soil (When earth is taken from bank cutting or from borrow pits ) including breaking of
clods, spreading to required line and level, forming, and cost of all labour complete as per cum 157.00
specifications. ( excluding watering and compaction of earth ) (with all lead and lift)
MORTH / Chapter 3
19.5 KSRRB 300-5. Excavation in soft rock with blasting for formation of roads including
stacking neatly, to uniform line and level including cost of explosives, labour, HOM of
machineries and equipments complete as per specifications. (with all lead and lift) MORTH / cum 348.00
Chapter 3
19.6 KSRRB 300-6. Excavation soft rock without blasting for formation of roads including
stacking neatly, to uniform line and level including cost of explosives, labour, HOM of
machineries and equipments complete as per specifications. (with all lead and lift) MORTH / cum 750.00
Chapter 3
19.7 KSRRB 300-7. Excavation in hard rock by blasting for formation of roads including
stacking to uniform line and level as directed by the engineer including cost of explosives,
labour, HOM of machineries and equipments complete as per specifications. (with all lead cum 468.00
and lift) MORTH / Chapter 3

Page 111 of 350


19.8 KSRRB 300-8. Excavation in hard rock by chiselling and / or wedging where blasting is
prohibited for formation of roads including stacking to uniform line and level including cost
of all labour complete as per specifications. (with all lead and lift) MORTH / Chapter 3 cum 1128.00

19.9 KSRRB M300-9. Excavation for roadway in soil using manual means including loading in
truck for carrying of cut earth to embankment site complete as per specifications. MORTH cum 146.00
Specification No. 301
19.10 KSRRB M300-10. Excavation in ordinary rock using manual means including loading in a
truck and carrying of excavated material to embankment site and complete as per cum 213.00
specifications. MORTH Specification No. 301
Page No. 142
19.11 Excavation in Soil with Dozer KSRRB M300-11.Excavation for road way in soil by
mechanical means including cutting and pushing the earth to site of embankment upto a
including trimming bottom and side slopes in accordance with requirements of lines, grades cum 68.00
and cross sections complete as per specifications. MORTH Specification No. 301

19.12 Excavation in Ordinary Rock with Dozer KSRRB M300-12. Excavation for roadway in
ordinary rock by deploying a dozer, 80 HP including cutting and pushing the cut earth to site
of embankment trimming bottom and side slopes in accordance with the requirements of cum 116.00
lines, grades and cross sections complete as per specifications. MORTH Specification No.
301
19.13 Excavation in Hard Rock (requiring blasting) with disposal KSRRB M300-13. Excavation
for roadway in hard rock (requiring blasting) by drilling, blasting and breaking, trimming of
bottom and side slopes in accordance with requirements of lines, grades and cross sections,
loading and disposal of cut road and complete as per specifications (Excavated rock credited cum 183.00
to contractor). MORTH Specification No. 301

19.14 Excavation in Soil using Hydraulic Excavator CK 90 and Tippers with Disposal KSRRB
M300-14. Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket
capacity including cutting and loading in tippers, trimming bottom and side slopes, in
accordance with requirements of lines, grades and cross sections, and transporting to the cum 46.00
embankment location and complete as per specifications. MORTH Specification No.301

19.15 Excavation in Ordinary Rock using Hydraulic Excavator CK-90 and Tippers with Disposal
KSRRB M300-15. Excavation for roadway in ordinary rock with hydraulic excavator of 0.9
cum bucket capacity including cutting and loading in tippers, transporting to embankment
site and trimming bottom and side slopes in accordance with requirements of lines, grades cum 62.00
and cross sections complete as per specifications. MORTH Specification No. 301

19.16 Excavation in Hard Rock (blasting prohibited) KSRRB M300-16.1. Excavation for roadway
in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in
tippers and disposal and trimming bottom and side slopes in accordance with requirements cum 365.00
of lines, grades and cross sections complete as per specifications. A. Mechanised MORTH
Specification No. 301
Page No. 143
19.17 Excavation in Hard Rock (blasting prohibited) KSRRB M300-16.2. Excavation for roadway
in hard rock (blasting prohibited) with rock breakers including breaking rock, loading in
tippers and disposal and trimming bottom and side slopes in accordance with requirements cum 682.00
of lines, grades and cross sections complete as per specifications. B. Manual Method.
MORTH Specification No. 301
19.18 KSRRB M300-17. Excavation for road way in hard rock ( controlled blasting) with rock
brakers including breaking rock, loading in tippers transporting to embankment site and
trimming bottom and side slopes in accordance with requirement of lines, grades and cross cum 203.00
sections complete as per specifications. MORTH Specification No. 301

Page 112 of 350


19.19 Excavation in Marshy Soil KSRRB M300-18. Excavation for roadway in marshy soil with
hydraulic excavator 0.9 cum bucket capacity including cutting and loading in tippers and
disposal and trimming of bottom and side slopes in accordance with requirements of lines, cum 52.00
grades and cross sections complete as per specifications. MORTH Specification No. 301

19.20 Removal of Unserviceable Soil with Disposal KSRRB M300-19. Removal of unserviceable
soil including excavation, loading and disposal but excluding replacement by suitable soil
which shall be paid separately as per clause 300.5 complete as per specifications. MORTH cum 37.00
Specification No. 301
19.21 Presplitting of Rock Excavation Slopes. KSRRB M300-20. Carrying out excavation in hard
rock to achieve a specified slope of the rock face by controlled use of explosives and blasting
accessories in properly aligned and spaced drill holes, collection of the excavated rock by a
80 HP dozer, loading in tipper by a front end loader and disposing of the material all as Sqm 91.00
specified in clause No. 300.3 complete as per specifications. MORTH Specification No. 303

19.22 Excavation for Structures. KSRRB M300-21.1. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 259.00
earth locally for road work complete as per specifications. i) Ordinary soil - A. Manual
Means (i) Depth upto 3 m. MORTH Specification No. 304

19.23 Excavation for Structures. KSRRB M300-21.2. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 48.00
earth locally for road work complete as per specifications. B. Mechanical Means (i) Depth
upto 3 m. MORTH Specification No. 304

19.24 Excavation for Structures. KSRRB M300-22.1. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 324.00
earth locally for road work complete as per specifications.ii) Ordinary Rock (not requiring
blasting) - A. Manual Means (i) Depth upto 3 m”. MORTH Specification No. 304

Page No. 144


19.25 Excavation for Structures. KSRRB M300-22.2. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 47.00
earth locally for road work complete as per specifications. ii)Ordinary Rock (not requiring
blasting)- B. Mechanical Means. MORTH Specification No. 304

19.26 Excavation for Structures. KSRRB M300-23. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 516.00
earth locally for road work complete as per specifications. iii) Hard Rock (requiring
blasting)- A. Manual Means. MORTH Specification No. 304

19.27 Excavation for Structures. KSRRB M300-24. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 471.00
earth locally for road work complete as per specifications. iv) Hard Rock ( blasting
prohibited) - A. Mechanical Means. MORTH Specification No. 304

Page 113 of 350


19.28 Excavation for Structures. KSRRB M300-25.2. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 469.00
earth locally for road work complete as per specifications. v) Marshy soil - A. Manual
Means (i) upto 3 m depth MORTH Specification No. 304

19.29 Excavation for Structures. KSRRB M300-25.3. Earth work in excavation of foundation of
structures as per drawing and technical specification, including setting out, construction of
shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and
bottom, backfilling the excavation earth to the extent required and utilising the remaining cum 101.00
earth locally for road work complete as per specifications. vi) Marshy soil B) Mechanical
means (ii) Upto 3m depth MORTH Specification No. 304

19.30 KSRRB 300- Extra additional lead KSRRB 300-26.1. Extra for every 7.5m additional lead
of 7.50 mtr. additional lead beyond 15m but upto 60m by manual means for all kinds of soils
except hard rock including cost of all labour complete as per specifications. MORTH cum 3.50
Chapter 3
19.31 KSRRB 300- Extra additional lead KSRRB 300-26.2. When lead is more than 60m upto
500m by any means of conveyance including loading and unloading for all kinds of soils
except hard rock including cost of all labour complete as per specifications. MORTH cum 4.00
Chapter 3
19.32 KSRRB 300-27. Dressing of earthwork including cutting and filling upto 15 cms thick or
depth including cost of all labour complete as per specifications. MORTH Chapter 3 cum 41.00

19.33 KSRRB 300-28. Box cutting / trenching the sub grade to proper slope, camber and removing
inequalities including removing the stuff and depositing on the road side slopes ( cutting of
earthwork shall be paid seperately in the respective item on the basis of classification of the Sqm 1.00
excavation) including cost of all labour complete as per specifications. MORTH Chapter 3

19.34 KSRRB M300- Stripping and Storing of top soil KSRRB M300-29. Stripping, Storing of top
soil by road side at 15 mt internal and re-application on embankment slopes. Cut slopes and
other areas in localities where the available embankment material is not condusive to plant cum 181.00
growth by manual means complete as per specifications. MORTH Specification No. 305

19.35 KSRRB M300-Stripping, Storing and Re-laying Top soil from Borrow Areas in Agriculture
Fields. KSRRB M300-30. Stripping, Storing and Re-laying Top soil from Borrow Areas in
Agriculture Fields. Stripping of top soil from borrow areas located in agriculture fields,
storing at a suitable place, spreading and re-laying after taking the borrow earth to maintain cum 41.00
fertility of the agricultural field, finishing it to the required levels and satisfaction of the
farmer complete as per specifications. MORTH Specification No. 305

Page No. 145


19.36 KSRRB M300- Turfing with Sods/Seeding and Mulching KSRRB M300-31. Turfing with
Sods-Furnishing and laying of the live sods of perenial turf forming grass on embankment
slope, verges or other locations shown on the drawing or as directed by the Engineer Sqm 20.00
including preparation of ground, fetching of sods and watering. complete as per
specifications. MORTH Specification No. 307
19.37 KSRRB M300-32. Preparation of seed bed on previously laid top soil, furnishing and
placing of seeds, fertilizer, mulching material, applying bituminous emulsion at the rate of
0.23 litres per sqm and laying and fixing jute netting, including watering for 3 months all as Sqm 68.00
per Clause 308 complete as per specifications. MORTH Specification No. 308

19.42 KSRRB M300- Sub-Surface Drains with Perforated Pipe. KSRRB M300-36. Construction
sub-surface drain with perforated pipe of 100 mm internal diameter of metal / asbestos
cement / cement concrete / PVC, closely jointed, perforations ranging from 3mm to 6mm
depending upon size of crushed stone material surrounding the pipe, with 150mm bedding m 515.00
below the pipe and 300mm cusion above the pipe, cross-section of excavation 450x550mm.
Excavated material to be utilised in roadway at site complete as per specifications. MORTH
Specification No. 309

Page 114 of 350


19.43 KSRRB M300- Sub-Surface Drains KSRRB M300-37. Construction of aggregate sub-
surface drain 300mm x 450mm with crushed stone aggregates conforming to Table 300-4,
excavated material to be utilised in roadway complete as per specifications. MORTH m 185.00
Specification No. 309
19.44 KSRRB M300-Underground Drain at Edge of Pavement KSRRB M300-38. Construction of
coverd drain 1m x 1m (inside dimension) with RCC M20 grade 10cm thick for walls and
floor, laid over 10cm thick 1:3:6 PCC bed and covered with M30 grade RCC slab of 15cm m 5567.00
thick excluding earth work including reinforcement @ 35 kg/rmt and form work complete
as per specifications. MORTH 309
19.45 KSRRB M300- Preparation and Surface Treatment of Formation. KSRRB M300-39.
Preparation and Surface Treatment of Formation by removing mud and slurry, watering to
the extent needed to maintain the desired moisture content, trimming to the required line,
grade, profile and rolling with 8-10 tonne smooth sheeled roller, complete as per Clause 310. Sqm 1.40
complete as per specifications. MORTH Specification No. 310

19.46 KSRRB M300 Earth work on Hill Road KSRRB M300-40. Excavation in hilly Areas in Soil
by Mechanical means. Excavation soil in hilly areas by mechanical means including cutting
and trimming of side slopes and disposing of excavated earth and complete as per cum 84.00
specifications. MORTH Specification No. 301
Page No. 146
19.47 KSRRB M300-41. Excavation in Hilly Areas in Ordinary Rock by Mechanical means not
requiring Blasting. Excavation in hilly area in ordinary rock not requiring blasting by
mechanical means including cutting and trimming of slopes and disposal of cut material and cum 129.00
complete as per specifications. MORTH Specification No. 301
19.48 KSRRB M300-42. Excavation in Hilly Areas in Hard Rock Requiring Blasting. Excavation
hilly areas in hard rock requiring blasting by mechanical means including trimming of slopes
and disposal of cut material and complete as per specification. MORTH Specification No. cum 274.00
301
19.50 KSRRB 300- Scarifying the surface and dressing KSRRB 300-44 Scarifying top bituminous
surface or surface dressing or premix carpet including picking up scarified materials,
stacking of old serviceable materials by manual means including cost of all abour charges Sqm 25.00
complete as per specifications. MORTH / Chapter 3
19.51 KSRRB 300-45. Scarifying stone metal crust 50mm to 100mm thick with pick axes along
with premix carpet / surface dressing and stacking of old serviceable materials by manual
means including cost of all labour charges complete as per specifications. MORTH / Chapter Sqm 50.00
3
19.52 KSRRB 300-46. Scarifying stone metal crust 50mm to 100mm thick by road roller with
scarifier along with 20mm premix carpet / surface dressing and stacking of old serviceable
materials including cost of all labour charges, HOM of machinaries complete as per Sqm 29.00
specifications. MORTH / Chapter 3
19.53 KSRRB 300-47. Scarifying kankar / gravel / metal crust upto 150mm thick with pick axes
and disposal of stuff including cost of all labour charges complete as per specifications. Sqm 25.00
MORTH / Chapter 3
19.54 KSRRB 300-48. Scarifying kankar / gravel / metal crust upto 150mm thick with power roller
and scarifier, disposal of stuff including cost of all labour charges, HOM of machineries Sqm 18.00
complete as per specifications. MORTH / Chapter 3
19.55 KSRRB 300-49. Scarifying bituminous course 50mm to 75mm thick along with premix
carpet / surface dressing by manual means without disturbing the base and stacking of the
debris materials including cost of all labour charges complete as per specifications. MORTH Sqm 57.00
/ Chapter 3
19.56 KSRRB 300-50. Scarifying bituminous course 50mm to 75mm thick along with premix
carpet / surface dressing by road roller attached with scarifier without disturbing the base and
stacking the debris including cost of all labour charges, HOM of machineries complete as Sqm 29.00
per specifications. MORTH / Chapter 3
Page No. 147
19.57 KSRRB 300-51. Making 50mm x 50mm furrows at 450 to the centre line of the road and at
one metre interval in the existing thin bituminous wearing course including sweeping, taking
out old materials, stacking the debris cost of all labour charges complete as per Sqm 3.00
specifications. MORTH / Chapter 3

Page 115 of 350


19.58 KSRRB M300- Scarifying Existing Granular Surface to a Depth of 50mm by Manual
Means. KSRRB M300-52.1. Scarifying the existing granular road surface to a depth of
50mm and disposal of scarified material and complete as per specifications. MORTH Sqm 20.00
Specification No. 305.4.3
19.59 KSRRB M300-52.2. Scarifying Existing Bituminous surface to a depth of 50mm by
Mechanical Means. Scarifying the existing bituminous road surface to a depth of 50mm and
disposal of scarified material and complete as per specifications. MORTH Specification No. Sqm 3.50
305.4.3
19.60 KSRRB M300- Construction of Embankment with Material Gravel/ Murrum. KSRRB
M300-53. Construction of embankment with approved material Gravel/Murrum with all lifts
and leads, transporting to site, spreading, grading to required slope and compacting to meet
requirement Table 300- 2 complete as per specifications.(Including cost of gravel / murrum, cum 302.00
watering charges & compaction by vibratory roller to 95% of proctors density) MORTH
Specification No. 305

19.61 KSRRB M300-Construction of Embankment with Material deposited from Roadway


cutting. KSRRB M300-54. Construction of embankment with approved material deposited
at site from roadway cutting and excavation from drain and foundation of other structures
graded and compacted to meet requirement of Table 300-2 complete asper cum 66.00
specifications.which includes , watering charges & compaction by vibratory roller) MORTH
Specification No. 305

19.62 KSRRB M300-Construction of Subgrade and Earthen Shoulders. KSRRB M300-55.


Construction of sub-grade and earthen shoulders with approved material Gravel/Murrum
with all lifts & leads, transporting to site, spreading, grading to required slope and
compacted to meet requirement of Table No. 300-2 complete as per specifications (including cum 331.00
cost of earth, watering charges & compaction by vibratory rollercompaction by vibratory
roller to 97% of proctors density) MORTH Specification No. 305

19.63 KSRRB M300-Construction of Rockfill Embankment. KSRRB M300-56. Construction of


rockfill embankment with availabel broken hard rock fragments of size not exceeding
300mm laid in layers not exceeding 500mm thick including filling of surface voids with
stone spalls, blinding top layer with granular material, rolled with vibratory road roller, all cum 37.00
complete as per Clause 313 complete as per specifications. MORTH Specification No. 313

Page No. 148


19.64 KSRRB 300-Compaction KSRRB 300-58. Compaction of original ground with maximum of
6 passes of 8 to 10 tonnes power roller including filling in depression occuring during rolling
including cost of all labour, HOM of machinery complete as per specifications. MORTH / Sqm 5.00
Chapter 3
19.65 KSRRB M300-59.1. Loosening of the ground upto a level of 500mm below the subgrade
level, watered, graded and compacted in layers to meet requirement of Table 300-2 for
subgrade construction complete as per specifications. Case-I:Compacting original ground cum 52.00
supporting subgrade.(which includes watering charges & compaction by vibratory roller)
MORTH Specification No. 305.3.4
19.66 KSRRB M300-59.2. Loosening, levelling and compacting origial ground supporting
embankment to facilitate placement of first layer of embankment, scarified to a depth of
150mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum
dry density as given in Table 300-2 for embankment construction. complete as per cum 25.00
specifications. Case-II: Compacting original ground supporting embankment.(which
includes watering charges & compaction by vibratory roller) MORTH Specification No.
305.3.4

19.67 KSRRB 300-60. Extra for laying earth by manual means as per specifications for
compaction in 250mm thick loose layers when laying of earth in layers is done
simultaneously with excavation of earth work and dressing but excluding rolling and cum 10.00
watering including cost of all labour complete as per specifications. MORTH / Chapter 3

Page 116 of 350


19.68 KSRRB 300-61. Extra for laying earth by manual means as per specifications for
compaction in 250mm thick loose layers when laying of earth in layers is done from stacked
materials including breaking of clods and dressing but excluding rolling and watering cum 43.00
including cost of all labour complete as per specifications. MORTH / Chapter 3

19.69 KSRRB 300-62. Extra for laying earth by mechanical means as per specifications for
compaction in 250mm thick loose layers when laying of earth in layers is done from stacked
materials including breaking of clods and dressing but excluding rolling and watering cum 24.00
including cost of all labour, HOM of machineries complete as per specifications. MORTH /
Chapter 3
19.70 KSRRB M300-63. Construction of Embankment with Flyash / Pond Ash available from
Coal or Lignite Burning Thermal Plants as Waste Material. Construction of embankment
with flyash conforming to Table 1 of IRC:SP:58-2001 obtained from coal or lignite burning
thermal power stations as waste material, spread and compacted in layer of 200mm thickness cum 82.00
each at OMC, all as specified in IRC:SP:58-2001 and as per approved plans complete as per
specifications.

19.71 KSRRB 300-64.1. Extra for watering the earth to bring the earth upto required optimum
moisture content manually including cost of all labour complete as per specifications. cum 7.00
MORTH / Chapter 3
Page No. 149
19.72 KSRRB 300-64.2. Extra for watering the earth to bring the earth upto required optimum
moisture content with mechinery including cost of all labour, HOM of machineries complete cum 2.00
as per specifications. MORTH / Chapter 3
19.73 KSRRB 300-65. Extra for rolling to specification with the use of vibratory roller when earth
is at suitable moisture content with desired field density not less than 95% of maximum dry
density ( modified heavy proctor test ) including HOM of machineries complete as per cum 16.00
specifications. MORTH / Chapter 3
19.74 KSRRB 300-66. Extra for rolling to specification with the use of vibratory roller when earth
is at suitable moisture content with desired field density not less than 100% of maximum dry
density ( modified heavy proctor test) including HOM of machineries complete as per cum 20.00
specifications. MORTH / Chapter 3
19.75 KSRRB 300-67. Extra for rolling to specification with power roller when earth is at suitable
moisture content with desired field density not less than 95% of maximum dry density
( ordinary proctor test ) including HOM of machineries complete as per specifications. cum 8.00
MORTH / Chapter 3
19.76 KSRRB 300-68. Extra for rolling to specification with power roller 8-10 tonne when earth is
at suitable moisture content with desired field density not less than 100% of maximum dry
density ( ordinary proctor test ) including HOM of machineries complete as per cum 10.00
specifications. MORTH / Chapter 3
19.77 KSRRB M300-Horticulture KSRRB M300-Spreading of sludge farm yard manure or/ and
good earth KSRRB M300-1. Spreading of sludge farm yard manure or/ and good earth in
required thickness (cost of sludge, farm yard manure or/and good earth to be paid for cum 65.00
separately) complete as per specifications. MORTH Specification No. 307
19.78 KSRRB M300- Grassing with Doobs grass KSRRB M300- 2.1. Grassing with Doobs grass
including watering and maintenance of the lawn for 30 days or more till the grass forms a
thick lawn free from weeds and fit for moving including supplying good earth if needed Sqm 47.00
complete as per specifications. MORTH Specification No. 307 i) In rows 15 cm apart in
either direction.
19.79 KSRRB M300-2.2. Grassing with Doobs grass KSRRB M300- 2.1. Grassing with Doobs
grass including watering and maintenance of the lawn for 30 days or more till the grass
forms a thick lawn free from weeds and fit for moving including supplying good earth if Sqm 90.00
needed complete as per specifications. MORTH Specification No. 307 ii) In rows 7.5 cm
apart in either direction
19.80 KSRRB M300-Making lawns including ploughing and dradding with ‘swagha’ breaking of
clod KSRRB M300-3. Making lawns including ploughing and breaking of clod, removal of
rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including Sqm 14.00
supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm complete as
per specifiifications. MORTH Specification No. 307
Page No. 150

Page 117 of 350


19.81 KSRRB M300- Maintenance of lawns or Turfing KSRRB M300-4.Maintenance of lawns or
Turfing of slopes (rough grassing) for a period of one year including watering etc complete Sqm 85.00
as per specifications. MORTH Specification No. 307
19.82 KSRRB M300-Turfing lawns with fine grassing including ploughing, dressing KSRRB
M300-5. Turfing lawns with fine grassing including ploughing, dressing including breaking
of clods, removal of rubbish, dressing and supplying doobs grass roots at 10 cm apart, Sqm 19.00
including supplying and spreading of farm yard manure at rate of 0.6 cum per 100 sqm
complete as per specifications. MORTH Specification No. 307
19.83 KSRRB M300- Maintenance of lawns with fine grassing for the first year KSRRB M300-6.
Maintenance of lawns with fine grassing for the first year including watering etc complete as Sqm 75.00
per specifications. MORTH Specification No. 307
19.84 KSRRB M300- Planting and maintenance permanent hedges KSRRB M300-7.1. Planting
permanent hedges including digging of trenches, 60 cm wide and 45 cm deep, refilling the
excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum per 100
metres and supplying and planting hedge plants at 30 cm apart complete as per m 85.00
specifications. A) Planting permanent hedges including digging of trenches MORTH
Specification No. 307

19.85 “KSRRB M300-7.2. Planting and maintenance permanent hedges KSRRB M300-7.1.
Planting permanent hedges including digging of trenches, 60 cm wide and 45 cm deep,
refilling the excavated earth mixed with farmyard manure, supplied at the rate of 4.65 cum m 129.00
per 100 metres and supplying and planting hedge plants at 30 cm apart complete as per
specifications. B) Maintenance of hedge for one year
19.86 KSRRB M300- Planting and Maintaining of Flowering Plants and Shrubs KSRRB M300-
8.1. Planting and Maintaining of Flowering Plants and Shrubs - A) Planting flowring plants m 22.00
and shrubs in central verge MORTH Specification No. 307
19.87 KSRRB M300- 8.2. Planting and Maintaining of Flowering Plants and Shrubs KSRRB
M300- 8.1. Planting and Maintaining of Flowering Plants and Shrubs B) Maintenance of Km 143078.00
flowering plants and shrubs in central verge for one year.
19.88 KSRRB M300- Planting of trees and their maintenance for one year KSRRB M300-9.
Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the
ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, Each 703.00
backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year
complete as per specifications. MORTH Specification No. 307
19.89 KSRRB M300-Renovation lawns including, weeding, forking the ground, top dressing with
forked soil KSRRB M300-10. Renovation lawns including, weeding, forking the ground, top
dressing with forked soil, watering and maintenance the lawns, for 30 days or more, till the
grass forms a thick lawn, free from weeds, and fit for moving and disposal of rubbish as Sqm 12.00
directed, including supplying good earth, if needed but excluding the cost of well decayed
farmyard namure complete as per specifications. MORTH Specification No. 308

Page No. 151


19.90 KSRRB M300-Supply at site of work well decayed farm yard manure KSRRB M300-11.
Supply at site of work well decayed farm yard manure, from any available source, approved
by the engineer in charge including screening and stackin complete as per specifications. cum 204.00
MORTH Specification No. 308.2
19.91 KSRRB 300-Supply at site of work/ store-deoiled neem cake KSRRB 300-12. Supply at site
of work/ store-deoiled neem cake duly packed in used gunny bags complete as per quintal 1100.00
specifications. MORTH Specification No. 308.2
19.92 KSRRB M300-Supplying sludge KSRRB M300-13. Supplying sludge duly stacked at
cum 204.00
site/store complete as per specifications. MORTH Specification No. 308.2
19.93 KSRRB M300- Half brick circular tree guard KSRRB M300-14. Half brick circular tree
guard, in 2nd class brick, internal diametre 1.25 metres, and height 1.2 metres, above ground
and 0.20 metre below ground, bottom two courses laid dry, and top three courses in cement Each 2166.00
mortar 1:6 (1 cement 6 sand) and the intermediate courses being in dry honey comb
masonry, as per design complete, complete as per specifications.
19.94 KSRRB M300-Edging with 2nd class bricks, laid dry lengthwise KSRRB M300-15. Edging
with 2nd class bricks, laid dry lengthwise, including excavation, refilling, consolidation,
with a hand packing and spreading nearly surplus earth within a lead of 50 metres complete m 44.00
as per specifications.

Page 118 of 350


19.95 KSRRB M300- Making tree guard from empty bitumen drums KSRRB M300-16. Making
tree guard 53 cm dia and 1.3 m high as per design from empty bitumen drum, slit suitably to
permit sun and air, (supplied by the department at stock issue rate) including providing and Each 336.00
fixing 2 nos MS sheet rings 50 x 0.5 mm with rivets, complete in all respect complete as per
specifications.
19.96 KSRRB M300-17. Making tree guard 53 cm dia and 2 metres high as per design from empty
bitumen drums, slit suitably to permit sun and air, (supplied by the department at stock issue
rate) including providing and fixing four legs 40 cm long of 30 x 3 mm MS riveted to tree Each 638.00
guard and providing and fixing 2 nos. MS sheet rings 50 x 0.5 mm with rivets complete in
all respects complete as per specifications.
19.97 KSRRB M300- Wrought iron and mild steel welded work KSRRB M300-18. Wrought iron
and mild steel welded work (using angles, square bars, tees and channel grills, grating
frames, gates and tree guards of any size and design etc. including cost of screens and
welding rods or bolts and nuts complete fixed in position but without the cost of excavation quintal 6332.00
and concrete for fixing which will be paid separately complete as per specifications.

Page No. 152


19.98 KSRRB M300-Tree guard with MS iron KSRRB M300-19. Providing and fixing MS iron
tree guard 60 cm dia and 2 metre high above ground level formed of 4 Nos (25 x 6 mm) and
8 Nos (25 x 3 mm) vertical MS riveted to 3 Nos (25 x 6 mm) iron rings in two halves, bolted
together with 8 mm dia and 30 mm long bolts including painting two coats with paint of Each 1704.00
approved brand over a coat of priming, complete in all respects, complete as per
specifications.

19.100. KSRRB M300-Tree gaurd with MS Angle and Steel wire KSRRB M300-20. Providing and
fixing tree gaurd 0.60 metre square, 2.00 metre high fabricated with MS angle iron 30 x 30 x
3 mm, MS iron 25 x 3 mm and steel wire 3 mm dia welded and fabricated as per design in Each 2230.00
two halves bolted together complete as per specifications
19.101. KSRRB M300-Compensatory afforestation KSRRB M300-21. Planting trees as
compensatory afforestation at the rate of 290 trees per hectare at a spacing of 6 m by
grubbing and leveling the ground upto a depth of 150 mm, digging holes 0.9 m dia, 1 m Ha 64816.00
deep, mixing farm yard/sludge manure with soil, planting of saple.
19.102. Milling the bituminous pavement surface upto a depth of 55 mm using milling machine,
to make a uniform surface without disturbing the base, cleaning the milled surface, including
cost of all labour charges and hire charges of machineries etc complete., including stacking Sqm 80.00
the milled material on the sides of road.
Page No. 153

20.0 20.SUB BASES-BASES (NON BITUMINOUS) AND SHOULDERS

20.1 KSRRB 400- Granular Sub-base KSRRB 400-1. Providing, laying, spreading and
compacting inverted choke of screening Type ‘ B ‘ or sand in sub-base course in uniform
layer on a prepared base by mechanical means with motor grader and compacting with cum 2477.00
power roller including cost of all materials, labour, HOM of machineries complete as per
specifications. MORTH Chapter 4
20.2 KSRRB 400-2. Providing, laying, spreading and compacting specified graded sand, gravel
or any other course material 60% and crushed stone aggregates of granite / trap / basalt 40%
in sub-base course including premixing the material at OMC in mechanical mixer (Pug mill),
carriage of mixed material up to 1km, spreading in uniform layers with motor grader on a
prepared base and compacting with power roller to achieve the desired density including all cum 1212.00
materials, labour, HOM of machinery, lighting, guarding, barricading and maintenance of
diversion complete as per specifications. MORTH Chapter 4

20.4.1 KSRRB M400-6.1. Construction of granular sub-base by providing close graded crushed
stone aggregates of granite / trap / basalt material, mixing in a mechaical mix plant at OMC,
carriage of mixed material to work site, spreading in uniform layers with motor grader on
prepared surface and compacting with vibratory power roller to achieve the desired density, cum 1618.00
complete as per specifications. A. Plant Mix Method. - Close graded granular sub-base
material as per 400-1 For Grading- I Material

Page 119 of 350


20.4.2 KSRRB M400-6.1. Construction of granular sub-base by providing close graded crushed
stone aggregates of granite / trap / basalt material, mixing in a mechaical mix plant at OMC,
carriage of mixed material to work site, spreading in uniform layers with motor grader on
prepared surface and compacting with vibratory power roller to achieve the desired density, cum 1571.00
complete as per specifications. A. Plant Mix Method. - For Grading II Material

20.4.3 KSRRB M400-6.1. Construction of granular sub-base by providing close graded crushed
stone aggregates of granite / trap / basalt material, mixing in a mechaical mix plant at OMC,
carriage of mixed material to work site, spreading in uniform layers with motor grader on
prepared surface and compacting with vibratory power roller to achieve the desired density, cum 1525.00
complete as per specifications. A. Plant Mix Method. - For Grading III Material

20.5.1 KSRRB M400-6.2. Construction of granular sub-base by providing close graded crushed
stone aggregates of granite / trap / basalt material, spreading in uniform layers with motor
grader on prepared surface, mixingby mix in place method by rotavator at OMC, and
compacting with vibratory power roller to achieve the desired density, complete as per cum 1459.00
specifications. B. By Mix in Place Method. - Close graded granular sub-base material as per
400-1 For Grading I Material

20.5.2 KSRRB M400-6.2. Construction of granular sub-base by providing close graded crushed
stone aggregates of granite / trap / basalt material, spreading in uniform layers with motor
grader on prepared surface, mixingby mix in place method by rotavator at OMC, and
compacting with vibratory power roller to achieve the desired density, complete as per cum 1408.00
specifications. B. By Mix in Place Method. - For Grading II Material

20.5.3 KSRRB M400-6.2. Construction of granular sub-base by providing close graded crushed
stone aggregates of granite / trap / basalt material, spreading in uniform layers with motor
grader on prepared surface, mixingby mix in place method by rotavator at OMC, and
compacting with vibratory power roller to achieve the desired density, complete as per cum 1353.00
specifications. B. By Mix in Place Method. - For Grading III Material

Page No. 155


20.6.1 KSRRB 400 Granular Sub-Base with Coarse Graded Material (table 400-2) KSRRB M400-
7. Construction of granular sub-base by providing Coarse graded crushed stone aggregates of
granite / trap / basalt material, speading in uniform layers with motor grader on prepared
surface, mixing by mix in place method with rotavator at OMC, and compacting with cum 1433.00
vibratory roller to achieve the desired density, complete as per specifications. - ForCoarse
graded granular sub-base material as per 400-2 For Grading I Material

20.6.2 KSRRB 400 Granular Sub-Base with Coarse Graded Material (table 400-2) KSRRB M400-
7. Construction of granular sub-base by providing Coarse graded crushed stone aggregates of
granite / trap / basalt material, speading in uniform layers with motor grader on prepared
surface, mixing by mix in place method with rotavator at OMC, and compacting with cum 1493.00
vibratory roller to achieve the desired density, complete as per specifications. - For Grading
II Material

20.6.3 KSRRB 400 Granular Sub-Base with Coarse Graded Material (table 400-2) KSRRB M400-
7. Construction of granular sub-base by providing Coarse graded crushed stone aggregates of
granite / trap / basalt material, speading in uniform layers with motor grader on prepared
surface, mixing by mix in place method with rotavator at OMC, and compacting with cum 1372.00
vibratory roller to achieve the desired density, complete as per specifications. - For Grading
III Material

20.7 KSRRB M400- Lime stabilization for improving subgrade KSRRB M400-8.1. Laying and
spreading available soil in the subgrade on a prepared surface, pulverising, mixing the spread
soil in place with rotavator with 3 per cent slaked lime having minimum content of 70 per
cent of CaO, grading with motor grader and compacting with the road roller at OMC to the cum 389.00
desired density to form a layer of improved subgrade complete as per specifications. A. By
Mechanical means MORTH Specification No. 402

Page 120 of 350


20.8 KSRRB M400-8.2. Lime Stabilisation for improving Subgrade Laying and spreading
available soil in the subgrade on a prepared surface, pulverising, mixing the spread soil in
place with rotavator with 3 per cent slaked lime having minimum content of 70 per cent of
CaO, grading with motor grader and compacting with the road roller at OMC to the desired cum 406.00
density to form a layer of improved subgrade. complete as per specifications. B. By Manual
means MORTH Specification No. 402

20.9 KSRRB M400- Lime Treated Soil for Sub-Base KSRRB M400-9. Providing, laying and
spreading soil on a prepared subgrade, pulverising, mixing the spread soil in place with
rotavator with 3% slaked lime with minimum content of 70 per cent of CaO, grading with
motor grader and compacting with the road roller at OMC to achieve atleast 98% of the cum 504.00
maximum dry density to form a layer of sub-base complete as per specifications. MORTH
Specification No. 402

20.10 KSRRB M400-Cement Treated Soil Sub-Base/Base KSRRB M400-10. Providing, laying
and spreading soil on a prepared subgrade, pulverising, adding the designed quantity of
cement to the spread soil, mixing in place with the rotavator, grading with the motor grader
and compacting with the road roller at OMC to achieve the desired unconfined compressive cum 1041.00
strength and to form a layer of sub-base/base complete as per specifications. ( For 4%
quantity of cement by weight of soil). MORTH Specification No. 403

Page No. 156


20.11.1 KSRRB M400-Cement Treated Crushed rock or Combination as per Clause 403.2 & Table
400.4 in Sub-Base/Base KSRRB M400-11. Providing, laying and spreading material on a
prepared subgrade, adding the Designed quantity of cement to the spread material, mixing in
place with the rotavator, grading with the motor grader and compacting with the road roller
at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-
cum 2428.00
base/base complete as per specifications. (Quantity of cement assumed as 4% of quantity of
crushed rock by weight) MORTH Specification No. 403 - Cement at site at 4% by wt. of
crushed aggregate (600 tonne) Grading of material for sub-base course

20.11.2 KSRRB M400-Cement Treated Crushed rock or Combination as per Clause 403.2 & Table
400.4 in Sub-Base/Base KSRRB M400-11. Providing, laying and spreading material on a
prepared subgrade, adding the Designed quantity of cement to the spread material, mixing in
place with the rotavator, grading with the motor grader and compacting with the road roller
at OMC to achieve the desired unconfined compressive strength and to form a layer of sub-
cum 2347.00
base/base complete as per specifications. (Quantity of cement assumed as 4% of quantity of
crushed rock by weight) MORTH Specification No. 403 - Cement at site at 4% by wt. of
crushed aggregate (600 tonne) Grading of material for base course

20.14.1 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing, laying, spreading
and compacting crushed stone aggregates of granite / trap / basalt specific sizes to water
bound macadam specifications including spreading in uniform thickness, hand packing,
rolling with 3- wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding materials to fill up the cum 1771.00
interstices of coarse aggregates, watering and compacting to the required density complete as
per Specification. A. By mannual means. MORTH Specification No. 404 - Type A 13.2mm
for grading II

20.14.2 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing, laying, spreading
and compacting crushed stone aggregates of granite / trap / basalt specific sizes to water
bound macadam specifications including spreading in uniform thickness, hand packing,
rolling with 3- wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding materials to fill up the
cum 1638.00
interstices of coarse aggregates, watering and compacting to the required density complete as
per Specification. A. By mannual means. MORTH Specification No. 404 - Crushable type
such as Moorum or Gravel for grading II

Page 121 of 350


20.14.3 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing, laying, spreading
andcompacting crushed stone aggregates of granite / trap / basalt specific sizes to water
bound macadam specifications including spreading in uniform thickness, hand packing,
rolling with 3- wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding materials to fill up the cum 1838.00
interstices of coarse aggregates, watering and compacting to the required density complete as
per Specification. A. By mannual means. MORTH Specification No. 404 - Type B 11.2mm
for grading III

20.14.4 KSRRB M400- Water Bound Macadam KSRRB M400-14.1. Providing, laying, spreading
and compacting crushed stone aggregates of granite / trap / basalt specific sizes to water
bound macadam specifications including spreading in uniform thickness, hand packing,
rolling with 3- wheeled steel/vibratory roller 8-10 tonnes in stages to proper grade and
camber, applying and brooming requisite type of screening/binding materials to fill up the
cum 1696.00
interstices of coarse aggregates, watering and compacting to the required density complete as
per Specification. A. By mannual means. MORTH Specification No. 404 - Crushable type
such as Moorum or Gravel for grading III

20.16 KSRRB M400- Crushed cement sub-base/base KSRRB M400- 15. Breaking and crushing of
material obtained by breaking damaged cement concrete slabs to size range not exceeding
75mm as specified in Table 400.7 transporting the aggregate obtained from breaking of
cement concrete slabs , laying and compacting the same as sub-base / base course, cum 246.00
constructed as WBM to Clause 400.4 except the use of screening or binding material
complete as per specifications. MORTH Specification No. 405

20.17 KSRRB M400- Penetration Coat over top layer of crushed cement concrete base KSRRB
M400-16. Spraying of bitumen over cleaned dry surface of crushed cement concrete base at
the rate of 25 kg per 10 sqm by a bitumen pressure distributor, spreading of key aggregates
at the rate of 0.13 cum per 10 sqm by a mechanical gritter and rolling the surface as per Sqm 106.00
Clause 500.6.3.8 complete as per specifications MORTH Specification No. 405.2

Page No. 157


20.18 KSRRB M400- Wet Mix Macadam KSRRB M400-17. Providing, laying, spreading and
compacting crushed stone aggregates of granite / trap / basalt to wet mix macadam
specifications including pre mixing the material with water at OMC in mechanical mix plant
carriage of mixed method of tipper to site, laying in uniform layers with paver in cum 1668.00
sub-base/base course on well prepared surface and compacting with vibratory roller to
achieve the desired density complete as per specifications. MORTH Specification No. 406

20.19 KSRRB M400-Construction of Median and Island with soil taken from Roadway cutting
KSRRB M400-18. Construction of Median and island above road level with approved
material deposited at site from roadway cutting and excavation for drain and foundation of cum 123.00
other structures, spread, graded and compacted as per Clause 400.7 complete as per
specifications. MORTH Specification No. 407
20.20 KSRRB M400-Construction of Median and island with Soil taken from Borrow Areas.
KSRRB M400-19. Construction of Median and island with Soil taken from Borrow Areas.
Construction of Median and island above road level with approved material deposited from cum 197.00
borrowpits, spread, sloped and compacted as per Clause 400.7 complete as per
specifications. MORTH Specification No. 407
20.21 KSRRB M400-Construction of footpath and separator KSRRB M400-21. Construction of
footpath/separator by providing a 150 mm compacted granular sub-base as per Clause 401 &
25mm thick cement concrete grade M-15, overlaid with precast concrete tiles in cement Sqm 672.00
mortar 1:3 including provision of all drainage arrangements but excluding kerb channel
complete as per specifications. MORTH Specification No. 409
20.22 KSRRB M400-22 Crusher Run Macadam Base KSRRB M400-22.1. Providing crushed
stone aggregates of granite / trap / basalt, depositing on a prepared surface by hauling
vehicles, spreading and mixing with a motor grader, watering and compacting with a
vibratory roller to Clause 410 to form a layer of sub-base/base. complete as per cum 1487.00
specifications. A. By mix in place method. (For 53 mm maximum size) MORTH
Specification No. 410

Page 122 of 350


20.23 KSRRB M400-22.1. Crusher Run Macadam Base KSRRB M400-22.1. Providing crushed
stone aggregates of granite / trap / basalt depositing on a prepared surface by hauling
vehicles, spreading and mixing with a motor grader, watering and compacting with a
vibratory roller to Clause 410 to form a layer of sub-base/base. complete as per cum 1522.00
specifications. A. By mix in place method. (For 45 mm maximum size) MORTH
Specification No. 410

20.24 KSRRB M400-22.2. Providing crushed stone aggregates of granite / trap / basalt material
depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor
gader, watering and compacting with a vibratory roller to Clause 410 to form a layer of sub- cum 1656.00
base/base. complete as per specifications. (For 53 mm maximum size ) B. By Mixing Plant
Method. MORTH Specification No. 410
Page No. 158
20.25 KSRRB M400-22.2. Providing crushed stone aggregate, depositing on a prepared surface by
hauling vehicles, spreading and mixing with a motor gader, watering and compacting with a
vibratory roller to Clause 410 to form a layer of sub-base/base. complete as per
specifications. (For 53 mm maximum size ) B. By Mixing Plant Method. MORTH cum 1707.00
Specification No. 410 B. By mixing Plant Method. ( For 45 mm maximum size) MORTH
Specification No. 410

20.26 KSRRB M400- Lime, Flyash stabilised Soil Sub-base. KSRRB M400-23. Lime, Flyash
stabilised Soil Sub-base. Construction of sub-base using lime-flyash admixture with granular
soil, free from organic matter/deleterious material or clayey silts and low plasticity clays
having PI between 5 & 20 and liquid limit less than 25 and commercial dry lime slaked at
site or pre-slaked with CaO content not less than 50%, flyash to conform to gradation as per
cum 372.00
Clause 43 of IRC: 88-1984, lime + flyash content ranging between 10 to 30%, the minimum
un-confined compressive strength and CBR value after 28 days curing and 4 days soaking to
be 7.5 kg/sqcm and 25% respectively, all as specified in IRC:88-1984 complete as per
specifications.

Page No. 159

21.0 21.BASE AND SURFACE COURSES (BITUMINOUS)

21.1 KSRRB 500-1. Cleaning the existing WBM road surface including removing of binding
materials and other foreign matter with wire brushes and small picks, sweeping with brooms
or soft brushes and finally dusting with old gunny bags and / or compressed air, to receive
bituminous treatment including cost of all materials, labour, HOM of machineries complete Sqm 13.00
as per specifications. MORTH specification clause 501

21.2 KSRRB 500-2. Cleaning the existing black topped surface with brooms, soft brushes and
finally dusting with old gunny bags and / or compressed air to receive bituminous treatment
including cost of all materials, labour, HOM of machineries complete as per specifications. Sqm 3.00
MORTH specification clause 501
21.3 KSRRB 500-3. Scarifying existing stone metal layer upto 75mm thick along with their
bituminous surface, picking up scarified materials and stacking of old serviceable materials
with lead of 100 m. sequential spreading of the salvaged aggregates with fresh aggregates on
prepared base and consolidating as per water bound macadam specifications including cost Sqm 87.00
of all labour, HOM of machineries complete as per specifications. MORTH specification
clause 501

21.5 Providing and applying primer coat for surfaces of medium porosity like cement
stabilized soil base @ 1.10kg/sqmt over prepared surface with S.S bitumen emulsion using
bitumen tanker fitted with spray set (excluding cleaning of road surface) including cost of all Sqm 56.00
material, labour, HOM of machineries complete as per specifications.. MORTH Chapter 5

21.6 KSRRB M500-6. Providing and applying primer coat with S.S. bitumen emulsion on
prepared surface of granular base such as WMM including cleaning of road surface and
spraying primer at the rate of 0.60 kg / sqm using mechanical means complete as per Sqm 26.00
specifications. MORTH Specification No. 502

Page 123 of 350


21.7 KSRRB 500-7. Providing and applying tack coat using 80/100 grade bitumen(VG10) on the
prepared black topped surfaces at 2.5 kg per 10 sqm, heating bitumen in boiler fitted with
spray set (excluding cleaning of road surface) including cost of all materials, labour, HOM Sqm 11.00
of machineries complete as per specifications. MORTH/Chapter 5

21.9 KSRRB 500-9. Providing and applying tack coat using 80/100 grade bitumen (VG10) on
granular base such as WBM surfaces hot bitumen primed at 4 kg per 10 sqm, heating
bitumen in boiler fitted with spray set (excluding cleaning of road surface) including cost of Sqm 18.00
all materials, labour, HOM of machineries complete as per specifications. MORTH / Chapter
5
Page No. 161
21.10.2 KSRRB M500-10. Providing and applying tack coat using 80/100 grade bitumen(VG10) in
boiler fitted with spray set distributor at the rate of
0.20 kg per sqm on the existing prepared bituminous surface cleaned with mchancial broom. Sqm 9.00
complete as per specifications. - using bitumen 80/100 on primed surfaces
21.11.1 KSRRB 500-11. Providing and laying bituminous macadam on prepared surface with
crushed coarse aggregates as per design mix formula for base / binding course including
loading of aggregates with F.E. loader, hot mixing of stone aggregates and bitumen in hot
mix plant, transporting the mixd material in tipper to paver and laying mixed materials with
paver finisher to the required level and grade, rolling by power roller to achieve the desired
cum 5033.00
density, but excluding cost of primer / tack coat including lead, lift and cost of all materials,
labour, HOM of machineries complete as per specifications. MORTH /Chapter 5 - using
100/120 TPH capacity H.M.P. with sensor paver Gr-1 (80 mm to 100mm) with 3.1 % VG-
30 Bitumen

21.11.2 KSRRB 500-11. Providing and laying bituminous macadam on prepared surface with
crushed coarse aggregates as per design mix formula for base / binding course including
loading of aggregates with F.E. loader, hot mixing of stone aggregates and bitumen in hot
mix plant, transporting the mixd material in tipper to paver and laying mixed materials with
paver finisher to the required level and grade, rolling by power roller to achieve the desired
cum 5409.00
density, but excluding cost of primer / tack coat including lead, lift and cost of all materials,
labour, HOM of machineries complete as per specifications. MORTH /Chapter 5 - using
100/120 TPH capacity H.M.P. with sensor paver Gr-II (50 mm to 75 mm) with 3.3 % VG-30
Bitumen

21.11.3 KSRRB 500-11. Providing and laying bituminous macadam on prepared surface with
crushed coarse aggregates as per design mix formula for base / binding course including
loading of aggregates with F.E. loader, hot mixing of stone aggregates and bitumen in hot
mix plant, transporting the mixd material in tipper to paver and laying mixed materials with
paver finisher to the required level and grade, rolling by power roller to achieve the desired
cum 4888.00
density, but excluding cost of primer / tack coat including lead, lift and cost of all materials,
labour, HOM of machineries complete as per specifications. MORTH /Chapter 5 - using
40/60 TPH capacity H.M.P. with sensor paver Gr-I (80 mm to 100 mm) with 3.1 % VG-30
Bitumen

21.11.4 KSRRB 500-11. Providing and laying bituminous macadam on prepared surface with
crushed coarse aggregates as per design mix formula for base / binding course including
loading of aggregates with F.E. loader, hot mixing of stone aggregates and bitumen in hot
mix plant, transporting the mixd material in tipper to paver and laying mixed materials with
paver finisher to the required level and grade, rolling by power roller to achieve the desired
density, but excluding cost of primer / tack coat including lead, lift and cost of all materials, cum 4992.00
labour, HOM of machineries complete as per specifications. MORTH /Chapter 5 - using
40/60 TPH capacity H.M.P. with sensor paver Gr-II (50 mm to 75 mm) with 3.3 % VG-30
Bitumen

Page 124 of 350


21.11.5 KSRRB 500-11. Providing and laying bituminous macadam on prepared surface with
crushed coarse aggregates as per design mix formula for base / binding course including
loading of aggregates with F.E. loader, hot mixing of stone aggregates and bitumen in hot
mix plant, transporting the mixd material in tipper to paver and laying mixed materials with
paver finisher to the required level and grade, rolling by power roller to achieve the desired
density, but excluding cost of primer / tack coat including lead, lift and cost of all materials, cum 4837.00
labour, HOM of machineries complete as per specifications. MORTH /Chapter 5 - using
40/60 TPH capacity H.M.P. with Mechanical paver Gr-I (80 mm to 100 mm) with 3.1 %
VG-30 Bitumen

21.11.6 KSRRB 500-11. Providing and laying bituminous macadam on prepared surface with
crushed coarse aggregates as per design mix formula for base / binding course including
loading of aggregates with F.E. loader, hot mixing of stone aggregates and bitumen in hot
mix plant, transporting the mixd material in tipper to paver and laying mixed materials with
paver finisher to the required level and grade, rolling by power roller to achieve the desired
density, but excluding cost of primer / tack coat including lead, lift and cost of all materials, cum 4941.00
labour, HOM of machineries complete as per specifications. MORTH /Chapter 5 - using
40/60 TPH capacity H.M.P. with Mechanical paver Gr-II (50 mm to 75 mm) with 3.3 %
VG-30 Bitumen

21.12 KSRRB 500-12. Providing, laying and consolidating of crushed stone aggregates on
prepared surface as per built up spray grout specifications 75mm thick, as base course
compacted in two layers composite construction of crushed stone aggregates with
application of bitumen binder after each layer and lay aggregate on the top of second layer Sqm 312.00
and rolling with power roller 8 to 10 tonne but excluding cost of primer / tack coat including
cost of all materials, labour, HOM of machineries complete as per specifications.MORTH
clause No. 506

Page No. 162


21.17.1 KSRRB M500-17. Providing and laying dense graded bituminous macadam using
crushed aggregates of specified grading, premixed with VG30 grade bituminous binder and,
transporting the hot mix to work site, laying to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5691.00
as per MORTH table 500-10 complete in all respects complete as per specifications..
MORTH Specification No. 507 - using 100/120 TPH capacity H.M.P. with sensor paver Gr-
1 (80 mm to 100mm) with 4 % VG-30 Bitumen

21.17.2 KSRRB M500-17. Providing and laying dense graded bituminous macadam using
crushed aggregates of specified grading, premixed with VG30 grade bituminous binder and,
transporting the hot mix to work site, laying to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6276.00
as per MORTH table 500-10 complete in all respects complete as per specifications..
MORTH Specification No. 507 -using 100/120 TPH capacity H.M.P. with sensor paver Gr-
II (50 mm to 75 mm) with 4.5 % VG-30 Bitumen

21.17.3 KSRRB M500-17. Providing and laying dense graded bituminous macadam using
crushed aggregates of specified grading, premixed with VG30 grade bituminous binder and,
transporting the hot mix to work site, laying to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5539.00
as per MORTH table 500-10 complete in all respects complete as per specifications..
MORTH Specification No. 507 - using 40/60 TPH capacity H.M.P. with sensor paver Gr-I
(80 mm to 100 mm) with 4 % VG-30 Bitumen

21.17.4 KSRRB M500-17. Providing and laying dense graded bituminous macadam using
crushed aggregates of specified grading, premixed with VG30 grade bituminous binder and,
transporting the hot mix to work site, laying to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6124.00
as per MORTH table 500-10 complete in all respects complete as per specifications..
MORTH Specification No. 507 - using 40/60 TPH capacity H.M.P. with sensor paver Gr-II
(50 mm to 75 mm) with 4.5 % VG-30 Bitumen

Page 125 of 350


21.17.5 KSRRB M500-17. Providing and laying dense graded bituminous macadam using
crushed aggregates of specified grading, premixed with VG30 grade bituminous binder and,
transporting the hot mix to work site, laying to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5483.00
as per MORTH table 500-10 complete in all respects complete as per specifications..
MORTH Specification No. 507 - using 40/60 TPH capacity H.M.P. with Mechanical paver
Gr-I (80 mm to 100 mm) with 4 % VG-30 Bitumen

21.17.6 KSRRB M500-17. Providing and laying dense graded bituminous macadam using
crushed aggregates of specified grading, premixed with VG30 grade bituminous binder and,
transporting the hot mix to work site, laying to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6071.00
as per MORTH table 500-10 complete in all respects complete as per specifications..
MORTH Specification No. 507 - using 40/60 TPH capacity H.M.P. with Mechanical paver
Gr-II (50 mm to 75 mm) with 4.5 % VG-30 Bitumen

21.20.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6066.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100/120 TPH capacity H.M.P. with sensor paver Gr-I (35 mm to 40
mm) with 4.5 % VG-30 Bitumen

21.20.2 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6401.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100/120 TPH capacity H.M.P. with sensor paver Gr-II (25 mm to 30
mm) with 5 % VG-30 Bitumen

21.20.3 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5916.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40/60 TPH capacity H.M.P. with sensor paver Gr-I (35 mm to 40mm)
with 4.5 % VG-30 Bitumen

21.20.4 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6280.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with sensor paver Gr-II (25 mm to 30
mm) with 5 % VG-30 Bitumen

21.20.5 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5860.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with Mechanical Paver Gr-I (35 mm to 40
mm) with 4.5 % VG-30 Bitumen

21.20.6 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6227.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with Mechanical Paver Gr-II (25 mm to
30 mm) with 5 % VG-30 Bitumen

Page 126 of 350


21.20.7 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5935.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100/120 TPH capacity H.M.P. with sensor paver Gr-I (35 mm to 40
mm) with 4.5 % VG-10 Bitumen

21.20.8 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6286.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100/120 TPH capacity H.M.P. with sensor paver Gr-II (25 mm to 30
mm) with 5 % VG-10 Bitumen

21.20.9 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5782.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40/60 TPH capacity H.M.P. with sensor paver Gr-I (35 mm to 40mm)
with 4.5 % VG-10 Bitumen

21.20.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
0 aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6134.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with sensor paver Gr-II (25 mm to 30
mm) with 5 % VG-10 Bitumen

21.20.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
1 aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 5956.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with Mechanical Paver Gr-I (35 mm to 40
mm) with 4.5 % VG-10 Bitumen

Page No. 163


21.20.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
2 aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 6081.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with Mechanical Paver Gr-II (25 mm to
30 mm) with 5 % VG-10 Bitumen

21.21.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 7392.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. do - using 100-120 TPH capacity H.M.P. with sensor paver grading I (35-
40mm) with 4.5% CRMB-55 grade

21.21.2 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 7906.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100-120 TPH capacity H.M.P. with sensor paver grading II (25-
30mm) with 5% CRMB-55 grade

Page 127 of 350


21.21.3 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 7242.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with sensor paver grading I (35-40mm)
with 4.5% CRMB-55 grade

21.21.4 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 7754.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with sensor paver grading II (25-30mm)
with 5% CRMB-55 grade

21.21.5 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 7188.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with mechanical paver grading I (35 -
40mm) with 4.5% CRMB-55 grade

21.21.6 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 7701.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with mechanical paver grading II (25-
30mm) with 5% CRMB-55 grade

21.21.7 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 10090.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100-120 TPH capacity H.M.P. with sensor paver grading I (35-40mm)
with 4.5% NRMB 70 / PMB 70 grade

21.21.8 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 10904.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100-120 TPH capacity H.M.P. with sensor paver grading II (25-
30mm) with 5% NRMB 70/ PMB 70 grade

21.21.9 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 9938.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with sensor paver grading I (35-40mm)
with 4.5% NRMB 70/ PMB 70 grade

21.21.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
0 aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 10751.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with sensor paver grading II (25-30mm)
with 5% NRMB 70/ PMB 70 grade

Page 128 of 350


21.21.1 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
1 aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction
as per MORTH specification clause No. 508 complete in all respects complete as per cum 9884.00
specifications. - using 40-60 TPH capacity H.M.P. with mechanical paver grading I (35-
40mm) with 4.5% NRMB 70/ PMB 70 grade

2121.12 KSRRB M500-18. Providing and laying semi dense bituminous concrete using crushed
aggregates of specified grading, premixed with bituminous binder and filler, transporting the
hot mix to work site, laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction cum 10698.00
as per MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with mechanical paver grading II (25-
30mm) with 5% NRMB 70/ PMB 70 grade

Page No. 164


21.22.1 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick with hot mix
plant, using crushed aggregates of specified grading, premixed with bituminous binder and
filler, transporting the hot mix to work site, laying with a paver finisher to the required
grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction as per MORTH specification clause No. 500.9 complete in cum 6847.00
all respects complete as per specifications. MORTH Specification No. 509 - using 100/120
TPH capacity H.M.P. with sensor paver Gr-I (50 to 65 mm) with 5.5 % VG-30 Bitumen

21.22.2 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick with hot mix
plant, using crushed aggregates of specified grading, premixed with bituminous binder and
filler, transporting the hot mix to work site, laying with a paver finisher to the required
grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction as per MORTH specification clause No. 500.9 complete in cum 7068.00
all respects complete as per specifications. MORTH Specification No. 509 - using 100/120
TPH capacity H.M.P. with sensor paver Gr-II (30 mm to 45 mm) with6 % VG-30 Bitumen

21.22.3 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick with hot mix
plant, using crushed aggregates of specified grading, premixed with bituminous binder and
filler, transporting the hot mix to work site, laying with a paver finisher to the required
grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction as per MORTH specification clause No. 500.9 complete in cum 6708.00
all respects complete as per specifications. MORTH Specification No. 509 - using 40/60
TPH capacity H.M.P. with sensor paver Gr-I (50 mm to 60mm) with 5.5 % VG-30 Bitumen

21.22.4 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick with hot mix
plant, using crushed aggregates of specified grading, premixed with bituminous binder and
filler, transporting the hot mix to work site, laying with a paver finisher to the required
grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction as per MORTH specification clause No. 500.9 complete in cum 6913.00
all respects complete as per specifications. MORTH Specification No. 509 - using40/60 TPH
capacity H.M.P. with sensor paver Gr-II (30 mm to 45 mm) with 6 % VG-30 Bitumen

21.22.5 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick with hot mix
plant, using crushed aggregates of specified grading, premixed with bituminous binder and
filler, transporting the hot mix to work site, laying with a paver finisher to the required
grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction as per MORTH specification clause No. 500.9 complete in cum 6653.00
all respects complete as per specifications. MORTH Specification No. 509 - using 40-60
TPH capacity H.M.P. with mechanical paver grading I (50-65mm) with 5.5%VG-30
Bitumen

Page 129 of 350


21.22.6 KSRRB M500-19. Providing and laying bituminous concrete 40 mm thick with hot mix
plant, using crushed aggregates of specified grading, premixed with bituminous binder and
filler, transporting the hot mix to work site, laying with a paver finisher to the required
grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to
achieve the desired compaction as per MORTH specification clause No. 500.9 complete in cum 6859.00
all respects complete as per specifications. MORTH Specification No. 509 - using40/60 TPH
capacity H.M.P. with Mechanical Paver Gr-II (30 mm to 45 mm) with 6 % VG-30 Bitumen

21.23.1 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 8408.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using 100/120 TPH capacity H.M.P. with sensor paver Gr-I (50 to 65mm)
with 5.5 % CRMB 55

21.23.2 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 8710.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using 100/120 TPH capacity H.M.P. with sensor paver Gr-II (30 mm to 45
mm) with6 % CRMB 55

21.23.3 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 8271.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using 40/60 TPH capacity H.M.P. with sensor paver Gr-I (50 mm to 60mm)
with 5.5 % CRMB 55

21.23.4 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 8557.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with sensor paver Gr-II (30 mm to 45mm)
with 6 % CRMB 55

21.23.5 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 8217.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with mechanical paver grading I (50 -
65mm) with 5.5% CRMB-55 grade

21.23.6 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 8502.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with Mechanical Paver Gr-II (30 mm to
45 mm) with 6 % CRMB 55

21.23.7 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 11580.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using 100/120 TPH capacity H.M.P. with sensor paver Gr-I (50 to 65 mm)
with 5.5 % NRMB 70/ PMB 70

Page 130 of 350


21.23.8 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 12046.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications.- using 100/120 TPH capacity H.M.P. with sensor paver Gr-II (30 mm to 45
mm) with 6 % NRMB 70/ PMB 70

21.23.9 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 11442.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using 40/60 TPH capacity H.M.P. with sensor paver Gr-I (50 mm to 60mm)
with 5.5 %NRMB 70/PMB 70

21.23.1 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
0 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 11893.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with sensor paver Gr-II (30 mm to 45
mm) with 6 % NRMB 70/ PMB 70

21.23.1 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
1 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 11388.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using 40-60 TPH capacity H.M.P. with mechanical paver grading I (50-
65mm) with 5.5% NRMB 70/ PMB 70

21.23.1 KSRRB M500-19. Providing and laying bituminous concrete using crushed aggregates of
2 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with paver finisher to the required grade, level and alignment, rolling with
smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per cum 11838.00
MORTH specification clause No. 509 complete in all respects complete as per
specifications. - using40/60 TPH capacity H.M.P. with Mechanical Paver Gr-II (30 mm to
45 mm) with 6 % NRMB 70/ PMB 70

Page No. 165


21.26 KSRRB 500-22. Providing and laying single coat surface dressing or first coat of the two
surface dressing with 0.15 cum/10 sqm crushed stone chippings passing 19mm & retained
on 13.20mm sieve as per Table 500-21and bitumen 12 kg / 10 sqm of VG-10 (80/100) as
wearing course consisting of a layer of bituminous binder laid on the prepared surface
followed by cover of crushed stone chippings of specified size (may be pre-coated also) and Sqm 77.00
rolling with power roller 8-10 tonne capacity including cost of all materials, labour, HOM of
machineries complete as per specifications. MORTHclause No.510

21.27 KSRRB 500-23. Providing and laying second coat surface dressing with 0.10 cum/10 sqm
crushed stone chippings passing 13.2mm & retained on 9.50mm sieve as per Table 500-
21and bitumen 10 kg / 10 sqm of VG-10 (80/100) as wearing course consisting of a layer of
bituminous binder laid on the prepared surface followed by cover of crushed stone chippings Sqm 62.00
of specified size (may be pre-coated also) and rolling with power roller 8-10 tonne capacity
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTHclause No.510

21.32 KSRRB 500-27. Providing and laying open graded premix carpet of 20mm thick on
prepared surface in a single course as wearing course composed of 11.2mm and 13.2mm size
stone aggregates 0.027 cum/ sqm premixd with bituminous binder at 1.46kg/sqm in mini hot
mix plant 6-10 tonne capacity laying manually and rolling with power roller 8-10 tonne, Sqm 114.00
excluding cost of tack coat, including cost of all materials, labour, HOM of machineries
complete as per specifications using VG 10 (80/100) grade. MORTH clause
No.511/Chapter 5

Page 131 of 350


21.33 KSRRB 500-28. Providing and laying open graded premix carpet of 20mm thick on
prepared surface in a single course as wearing course composed of 11.2mm and 13.2mm size
stone aggregates 0.027 cum/ sqm premixd with bituminous binder at 1.46kg/sqm in mini hot
mix plant 6-10 tonne capacity laying manually and rolling with power roller 8-10 tonne, Sqm 135.00
excluding cost of tack coat, including cost of all materials, labour, HOM of machineries
complete as per specifications using VG 10 (80/100) grade. MORTH clause No.511/Chapter
5.- (Using CRMB 55 grade)

21.36 KSRRB 500-30. Providing and laying 20 mm thick mix seal surfacing Type A on prepared
surface as wearing course with specified graded crushed aggregates of 5.6mm and 11.2mm
size 0.027 cum/sqm premixd with bituminous binder at 2.20kg/sqm), in hotmix plant 40/60
tonne, transporting the mixed materials in tipper and laying with machanical paver finisher
to required level and grade, rolling with power roller 8-10 tonne, excluding cost of tack coat Sqm 135.00
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTH clause No.512 - using VG-30 (60/70 grade)

21.37 KSRRB 500-31. Providing and laying 20 mm thick mix seal surfacing Type A on prepared
surface as wearing course with specified graded crushed aggregates of 5.6mm and 11.2mm
size 0.027 cum/sqm premixd with bituminous binder at 2.20kg/sqm), in hotmix plant 40/60
tonne, transporting the mixed materials in tipper and laying with machanical paver finisher
to required level and grade, rolling with power roller 8-10 tonne, excluding cost of tack coat Sqm 163.00
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTH clause No.512 - using CRMB 55 grade Bitumen

21.38 KSRRB 500-32. Providing and laying 20 mm thick mix seal surfacing Type-B on prepared
surface as wearing course with specified graded crushed aggregates of 5.6mm and 13.2mm
size 0.027 cum/sqm premixed with bituminous binder at 1.90kg/sqm in hotmix plant 40/60
TPH, transporting the mixed materials in tipper and laying with machanical paver finisher to
required level and grade, rolling with power roller 8-10 tonne, excluding cost of tack coat Sqm 125.00
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTH clause No.512 - using VG 30 (60/70 grade) bitumen

Page No. 166


21.39 KSRRB 500-33. Providing and laying 20 mm thick mix seal surfacing Type-B on prepared
surface as wearing course with specified graded crushed aggregates of 5.6mm and 13.2mm
size 0.027 cum/sqm premixd with bituminous binder at 1.90kg/sqm in hotmix plant 40/60
TPH, transporting the mixed materials in tipper and laying with machanical paver finisher to
required level and grade, rolling with power roller 8-10 tonne, excluding cost of tack coat Sqm 150.00
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTH clause No.512 - - using CRMB 55 grade Bitumen

21.40 KSRRB 500-34. Providing and laying 20 mm thick mix seal surfacing Type A on prepared
surface in a single course composed of specified graded crushed aggregates 5.6mm to
11.2mm size 0.027 cum/sqm premixd with bitumen binder at 2.20 kg/sqm of in a minimix
plant 6 /10 tonne capacity, laying manually and rolling with power roller 8-10 tonne Sqm 141.00
excluding cost of tack coat including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH clause No.512 - using VG-30 (60/70) bitumen

21.41 KSRRB 500-35. Providing and laying 20 mm thick mix seal surfacing Type A on prepared
surface in a single course composed of specified graded crushed aggregates 5.6mm to
11.2mm size 0.027 cum/sqm premixd with bitumen binder at 2.20 kg/sqm of in a minimix
plant 6 /10 tonne capacity, laying manually and rolling with power roller 8-10 tonne Sqm 169.00
excluding cost of tack coat including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH clause No.512 - - using CRMB 55 grade Bitumen

Page 132 of 350


21.42 KSRRB 500-36. Providing and laying 20 mm thick mix seal surfacing Type ‘ B ‘ on
prepared surface in a single course composed of specified graded crushed aggregates 5.6mm
to 13.2mm size premixed with bitumen binder @ 1.90 kg/sqm of VG-30 (60/70) in a
minimix plant 6 / 10 tonne, laying manually and rolling with power roller 8-10 tonne Sqm 134.00
excluding cost of tack coat including cost of all materials, labour, HOM of machineries
complete as per specifications . MORTH clause No.512

21.43 KSRRB 500-37. Providing and laying 20 mm thick mix seal surfacing Type ‘ B ‘ on
prepared surface in a single course composed of specified graded crushed aggregates 5.6mm
to 13.2mm size premixed with bitumen binder @ 1.90 kg/sqm of CRMB 55 grade in a
minimix plant 6 / 10 tonne, laying manually and rolling with power roller 8-10 tonne Sqm 154.00
excluding cost of tack coat including cost of all materials, labour, HOM of machineries
complete as per specifications . MORTH clause No.512

21.45.1 KSRRB M500- 39.1 and 39.2. Providing and laying SEAL COAT for sealing the voids on
Bituminous surface, laid to the specified levels, grade and cross fall manually and rolling
with power roller 8 - 10 tonne capacity including cost of all materials, labour, HOM of
machinery complete as per the specifications. MORTH Specification No. 513 - TYPE A - Sqm 47.00
using graded aggregates 6.7mm and down size at 0.009 cum/sqm with bitumen binder VG-
10 (80/100 grade) at 0.98 kg/sqm.

21.45.2 KSRRB M500- 39.1 and 39.2. Providing and laying SEAL COAT for sealing the voids on
Bituminous surface, laid to the specified levels, grade and cross fall manually and rolling
with power roller 8 - 10 tonne capacity including cost of all materials, labour, HOM of
machinery complete as per the specifications. MORTH Specification No. 513 -TYPE B - Sqm 36.00
using graded aggregates 2.36mm and down size at 0.006 cum/sqm with bitumen binder VG-
10 (80/100 grade) at 0.68 kg/sqm.

21.47 KSRRB M500- Mastic asphalt KSRRB M500-41. Providing and laying 25 mm thick
mastic asphalt wearing course with paving grade bitumen@ 5.82 kg/sqmt meeting the
requirements given in table 500-29, prepared by using mastic cooker and laid to required
level and slope after cleaning the surface, including providing antiskid surface with bitumen
precoated fine grained hard stone chipping of 13.2 mm nominal size at the rate of 0.005cum
per 10 sqm and at an approximate spacing of 10 cm center to center in both directions, Sqm 448.00
pressed into surface when the temperature of surfaces is not less than 100°C, protruding 1
mm to 4 mm over mastic surface, complete as per clause 500.15 as per specifications.
MORTH Specification No. 515

Page No. 167


21.53 KSRRB M500-48. Providing and applying slow setting bitumen emulsion@at 0.75 kg/sqm
for sealing cracks less than 3 mm wide or incipient fretting or disintegration in an existing
bituminous surfacing complete as per specifications. MORTH Specification No. 518 Sqm 32.00

21.54 KSRRB M500-48. Providing and applying low viscosity bitumen emulsion with crushed
stone grit 3mm size for sealing cracks less than 3 mm wide or incipient fretting or
disintegration in an existing bituminous surfacing complete as per specifications. (emulsion Sqm 7.00
2% of grit, 3.75 kg/sqm) (In case it is decided by the Engineer to blind the fog spray)

21.55 KSRRB M500-49.1. Providing, laying and rolling of bituminous cold mix on prepared base
consisting of a mixture of unheated mineral aggregate and emulsified or cutback bitumen,
including mixing in a plant of suitable type and capacity, transporting, laying, compacting
and finishing to specified grades and levels complete as per specifications. Case - I : using cum 9409.00
bitumen emulsion at 175 kgs/cum & 9.5mm or 13.2mm nominal size aggregate” MORTH
Specification No. 519

21.56 KSRRB M500-49.2. Providing, laying and rolling of bituminous cold mix on prepared base
consisting of a mixture of unheated mineral aggregate and emulsified or cutback bitumen,
including mixing in a plant of suitable type and capacity, transporting, laying, compacting
and finishing to specified grades and levels complete as per specifications.Case - II : using cum 9365.00
bitumen emulsion at 175 kgs/cum & 19mm to 26.5mm nominal size aggregate MORTH
Specification No. 519

Page 133 of 350


21.57 KSRRB M500-49.3. Providing, laying and rolling of bituminous cold mix on prepared base
consisting of a mixture of unheated mineral aggregate and emulsified or cutback bitumen,
including mixing in a plant of suitable type and capacity, transporting, laying, compacting
and finishing to specified grades and levels complete as per specifications. Case - III : using cum 10960.00
cutback bitumen at 110 kgs/cum & 9.5mm or 13.2mm nominal size aggregate . MORTH
Specification No. 519

21.58 KSRRB M500-49.4. Providing, laying and rolling of bituminous cold mix on prepared base
consisting of a mixture of unheated mineral aggregate and emulsified or cutback bitumen,
including mixing in a plant of suitable type and capacity, transporting, laying, compacting
and finishing to specified grades and levels complete as per specifications.- Case - IV : cum 10903.00
Using cutback bitumen at 110 kgs/cum & 19mm or 26.5mm nominal size aggregate
MORTH Specification No. 519

21.64 KSRRB M500-56.1. Providing and laying slurry seal consisting of a mixture of fine
aggregates, portland cement filler, bituminous emulsion and water on a road surface
including cleaning of surface, mixing of slurry seal in a suitable mobile plant, laying and Sqm 52.00
compacting to provide even riding surface Complete as per specifications. Case - I : 5mm
thickness MORTH Specification No. 516
21.65 KSRRB M500-56.2. -Providing and laying slurry seal consisting of a
mixture of fine aggregates, portland cement filler, bituminous emulsion
and water on a road surface including cleaning of surface, mixing of
slurry seal in a suitable mobile plant, laying and compacting to provide Sqm 36.00
even riding surface Complete as per specifications.- Case - II : 3mm thickness MORTH
Specification No. 516
Page No. 168
21.66 KSRRB M500-56.3. Providing and laying slurry seal consisting of a
mixture of fine aggregates, portland cement filler, bituminous emulsion
and water on a road surface including cleaning of surface, mixing of
slurry seal in a suitable mobile plant, laying and compacting to provide Sqm 22.00
even riding surface Complete as per specifications.- Case - III : 1.5mm thickness MORTH
Specification No. 516

21.67 KSRRB M500-57.1. Providing and laying of a stress absorbing membrane over a cracked
road surface, with crack width below 6 mm after cleaning with a mechanical broom, using
modified binder complying with clause 521, sprayed at the rate of 9 kg per 10 sqm and
spreading 5.6 mm crushed stone aggregates at 0.11 cum per 10 sqm with hydraulic chip
spreader, sweeping the surface for uniform spread of aggregates and surface finished to Sqm 58.00
conform to clause 900.2 complete as per specification. Case - I :Stress absorbing membrane
(SAM) crack width less than 6mm MORTH Specification No. 522

21.68 “KSRRB M500-57.2. Providing and laying of a stress absorbing membrane over a cracked
road surface, with crack width 6 to 9 mm after cleaning with a mechanical broom, using
modified binder complying with clause 521, sprayed at the rate of 11 kg per 10 sqm and
spreading 11.2 mm crushed stone aggregates at 0.12 cum per 10 sqm, sweeping the surface Sqm 72.00
for uniform spread of aggregates and surface finished to conform to clause 900.2 complete
as per specification. Case - II :Stress absorbing membrane (SAM) crack width 6mm to
9mm” MORTH Specification No. 522

21.69 KSRRB M500-57.3. Providing and laying a single coat of a stress absorbing membrane over
a cracked road surface, with crack width above 9 mm and cracked area above 50% after
cleaning with a mechanical broom, using modified binder complying with clause 521,
sprayed at the rate of 15 kg per 10 sqm and spreading 11.2 mm crushed stone aggregates at
0.12 cum per 10 sqm, sweeping the surface for uniform spread of aggregates and surface Sqm 93.00
finished to conform to clause 900.2 complete as per specification. Case - III :Stress
absorbing membrane (SAM) crack width above 9 mm and cracked aread above 50%
MORTH Specification No. 522

21.70 KSRRB M500-57.4. Providing and laying a bitumen impregnated geotextile layer after
cleaning the road surface, geotextile conforming to requirements of clause 700.3.3, laid over
a tack coat with 1.05 kg per sqm of paving grade bitumen 80 - 100 penetration and
constructed to the requirement of clause 700.3.4.5 complete as per specification. Case - IV : Sqm 127.00
Bitumen impregnated geotextile MORTH Specification No. 522

Page 134 of 350


21.71 KSRRB M500-Recipe Cold Mixes KSRRB M500-58.1. Providing and laying of premix of
crushed stone aggregates of 40 mm down size and emulsion binder at 98 kgs/cum mixed in a
batch type cold mixing plant, laid over prepared surface, by paver finisher, rolled with a
pneumatic tyred roller initially and finished with a smooth steel wheel roller, all as per cum 6101.00
clause 500.19.3 complete as per specifications. Case - I : 75 mm thickness MORTH
Specification No. 519.3
Page No. 169
21.72 KSRRB M500-58.2. KSRRB M500-58.1. Providing and laying of premix of crushed stone
aggregates of 13.20 mm down size and emulsion binder at 153 kg/cum mixed in a batch type
cold mixing
plant, laid over prepared surface, by paver finisher, rolled with a cum 8471.00
pneumatic tyred roller initially and finished with a smooth steel wheel
roller, all as per clause 500.19.3 complete as per specifications.- Case - II : 40 mm thickness
MORTH Specification No. 519.3

21.73 KSRRB M500-58.3. KSRRB M500-58.1. Providing and laying of premix of crushed stone
aggregates 6.0mm down size and emulsion binder at 186 kgs/cum mixed in a batch type cold
mixing plant, laid over prepared surface, by paver finisher, rolled with a
pneumatic tyred roller initially and finished with a smooth steel wheel cum 9409.00
roller, all as per clause 500.19.3 complete as per specifications. Case - III : 25 mm thickness
MORTH Specification No. 519.3

21.74.1 KSRRB M500-47. Recycling pavement by cold milling of existing bituminous layers,
planing the surface after cold milling, reclaiming excavated material to the extent of 30 per
cent of the required quantity, hauling and stock piling the reclaimed material near the central
recycling plant after carrying out necessary checks and evaluation, adding fresh material
including rejuvenators as required, mixing in a 40/60 TPH hot mix plant, transporting to site
and laying with mechanical paver and compacting to the required grade, level and thickness cum 4694.00
including cost of all materials and labour etc., complete as specified in MORTH clause 517.
- using milling machine for DBM grade II (50mm to 75mm thick) using
bitumen binder VG-30 (60/70 grade) to achieve 4.50% bitumen content.

21.74.2 KSRRB M500-47. Recycling pavement by cold milling of existing bituminous layers,
planing the surface after cold milling, reclaiming excavated material to the extent of 30 per
cent of the required quantity, hauling and stock piling the reclaimed material near the central
recycling plant after carrying out necessary checks and evaluation, adding fresh material
including rejuvenators as required, mixing in a 40/60 TPH hot mix plant, transporting to site
and laying with mechanical paver and compacting to the required grade, level and thickness cum 4708.00
including cost of all materials and labour etc., complete as specified in MORTH clause 517.
- Scarifying using roller attached scarifier - for DBM grade II (50mm to 75mm thick) using
bitumen binder VG-30 (60/70 grade) to achieve 4.50% bitumen content.

21.74.3 KSRRB M500-47. Recycling pavement by cold milling of existing bituminous layers,
planing the surface after cold milling, reclaiming excavated material to the extent of 30 per
cent of the required quantity, hauling and stock piling the reclaimed material near the central
recycling plant after carrying out necessary checks and evaluation, adding fresh material
including rejuvenators as required, mixing in a 40/60 TPH hot mix plant, transporting to site
and laying with mechanical paver and compacting to the required grade, level and thickness cum 3576.00
including cost of all materials and labour etc., complete as specified in MORTH clause 517.
- using milling machine for BM grade II (50mm to 75mm thick) using
bitumen binder VG-30 (60/70 grade) to achieve 3.30% bitumen content

Page 135 of 350


21.74.4 KSRRB M500-47. Recycling pavement by cold milling of existing bituminous layers,
planing the surface after cold milling, reclaiming excavated material to the extent of 30 per
cent of the required quantity, hauling and stock piling the reclaimed material near the central
recycling plant after carrying out necessary checks and evaluation, adding fresh material
including rejuvenators as required, mixing in a 40/60 TPH hot mix plant, transporting to site
and laying with mechanical paver and compacting to the required grade, level and thickness cum 3589.00
including cost of all materials and labour etc., complete as specified in MORTH clause 517.
- Scarifying using roller attached scarifier - for BM grade II (50mm to 75mm thick) using
bitumen binder VG-30 (60/70 grade) to achieve 3.30% bitumen content.

21.75 Providing and laying 20 mm thick mix seal surfacing Type A on prepared surface as
wearing course with specified graded crushed aggregates of 5.6mm and 11.2mm size 0.027
cum/sqm premixd with modified bituminous binder at 2.20 kg/sqm consisting of 2.024 kg of
VG- 10 bitumen (80/100 grade) and Plastomeric Thermoplastics (Waste Plastic Additive) @
0.176 kg, in hotmix plant 40/60 TPH, transporting the mixed materials in tipper and laying
Sqm 131.00
with machanical paver finisher to required level and grade, rolling with power roller 8-10
tonne, excluding cost of tack coat, including cost of all materials, labour, HOM of
machineries complete as per specifications. MORTH clause No.512

21.76 Providing and laying 20 mm thick mix seal surfacing Type B on prepared surface as
wearing course with specified graded crushed aggregates of 5.6mm and 13.2mm size 0.027
cum/sqm premixd with modified bituminous binder at 1.90 kg/sqm consisting of 1.748 kg of
VG- 10 bitumen (80/100 grade) and Plastomeric Thermoplastics (Waste Plastic Additive) @
0.152 kg, in hotmix plant 40/60 TPH, transporting the mixed materials in tipper and laying
Sqm 122.00
with machanical paver finisher to required level and grade, rolling with power roller 8-10
tonne, excluding cost of tack coat, including cost of all materials, labour, HOM of
machineries complete as per specifications.MORTH clause No.512

Page No. 170


21.77.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per
cum 5892.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-1 (35 mm to 40
mm) with 4.5 % of modified bitumen binder consisting of VG-10 Bitumen (80/100 grade)
and 0.36% of Plastomeric Thermoplastics (Waste plastic Additive).

21.77.2 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6238.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-2 (25 mm to 30
mm) with 5 % of modified bitumen binder consisting of Plastomeric Thermoplastics (Waste
plastic Additive).

21.77.3 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per
cum 5739.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-1 (35 mm to 40 mm)
with 4.5 % of modified bitumen binder consisting of 4.14% VG- 10 bitumen (80/100 grade)
0.36% Plastomeric Thermoplastics (Waste plastic Additive).

Page 136 of 350


21.77.4 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6086.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II with 5 % of
modified bitumen binder consisting of 4.60% VG- 10 bitumen (80/100 grade) 0.4%
Plastomeric Thermoplastics (Waste plastic Additive).

21.77.5 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 5686.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I (35-40mm) with
4.5 % of modified bitumen binder consisting of 4.14% VG- 10 bitumen (80/100 grade)
0.36% Plastomeric Thermoplastics (Waste plastic Additive).

21.77.6 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6033.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I (25-30mm) with 5
% of modified bitumen binder consisting of 4.6% VG- 10 bitumen (80/100 grade) 0.40%
Plastomeric Thermoplastics (Waste plastic Additive).

21.77.7 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per
cum 6014.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-1 (35 mm to 40
mm) with 4.5 % of modified bitumen binder consisting of VG-30 Bitumen (60/70 grade)
and 0.36% of Plastomeric Thermoplastics (Waste plastic Additive).

21.77.8 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-II (25 mm to 30 cum 6375.00
mm) with 5 % of modified bitumen binder consisting of VG-30 Bitumen (60/70 grade) and
0.40% Plastomeric Thermoplastics (Waste plastic Additive).

21.77.9 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 5862.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-1 (35 mm to 40 mm)
with 4.5 % of modified bitumen binder consisting of 4.14% VG- 30 bitumen (60/70 grade)
0.36% Plastomeric Thermoplastics (Waste plastic Additive).

21.77.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
0 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6222.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II with 5 % of
modified bitumen binder consisting of 4.60% VG- 30 bitumen (60/70 grade) 0.40%
Plastomeric Thermoplastics (Waste plastic Additive).

Page No. 171

Page 137 of 350


21.77.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
1 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 5809.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-I (35-40mm)
with 4.5 % of modified bitumen binder consisting of 4.14% VG- 30 bitumen (60/70 grade)
0.36% Plastomeric Thermoplastics (Waste plastic Additive).

21.77.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
2 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6169.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-II (25-30mm)
with 5 % of modified bitumen binder consisting of 4.60% VG- 30 bitumen (60/70 grade)
0.40% Plastomeric Thermoplastics (Waste plastic Additive).

21.78.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6672.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-I (50-65mm) with
5.2 % of modified bitumen binder consisting of 4.78% VG- 10 bitumen (80/100 grade)
0.42% Plastomeric Thermoplastics (Waste plastic Additive).

21.78.2 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6867.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-II (30-45mm)
with 5.4 % of modified bitumen binder consisting of 4.97% VG- 10 bitumen (80/100 grade)
0.43% Plastomeric Thermoplastics (Waste plastic Additive).

21.78.3 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6154.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I (50-65mm) with
5.2 % of modified bitumen binder consisting of 4.78% VG- 10 bitumen (80/100 grade)
0.42% Plastomeric Thermoplastics (Waste plastic Additive).

21.78.4 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6711.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II (30-45mm) with
5.4 % of modified bitumen binder consisting of 4.97% VG- 10 bitumen (80/100 grade)
0.43% Plastomeric Thermoplastics (Waste plastic Additive).

21.78.5 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per
cum 6332.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-I (50-65mm)
with 5.2 % of modified bitumen binder consisting of 4.78% VG- 10 bitumen (80/100 grade)
0.42% Plastomeric Thermoplastics (Waste plastic Additive).

Page 138 of 350


21.78.6 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per
cum 6889.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-II (30-45mm)
with 5.4 % of modified bitumen binder consisting of 4.97% VG- 10 bitumen (80/100 grade)
0.43% Plastomeric Thermoplastics (Waste plastic Additive).

21.78.7 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6817.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-I (50-65mm) with
5.2 % of modified bitumen binder consisting of 4.78% VG- 30 bitumen (60/70 grade) 0.42%
Plastomeric Thermoplastics (Waste plastic Additive).

21.78.8 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 7019.00
specifications. - using 100-120 TPH capacity HMP with sensor Paver, Gr-II (30-45mm)
with 5.4 % of modified bitumen binder consisting of 4.97% VG- 10 bitumen (60/70 grade)
0.43% Plastomeric Thermoplastics (Waste plastic Additive).

Page No. 172

21.78.9 Providing and laying semi dense bituminous concrete using crushed aggregates of
specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6299.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I (50-65mm) with
5.2 % of modified bitumen binder consisting of 4.78% VG- 30 bitumen (60/70 grade) 0.42%
Plastomeric Thermoplastics (Waste plastic Additive).

21.78.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
0 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6863.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-II (30-45mm) with
5.4 % of modified bitumen binder consisting of 4.97% VG- 30 bitumen (60/70 grade) 0.43%
Plastomeric Thermoplastics (Waste plastic Additive).

21.78.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
1 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 6477.00
specifications. - using 40-60 TPH capacity HMP with sensor Paver, Gr-I (50-65mm) with
5.2 % of modified bitumen binder consisting of 4.78% VG- 30 bitumen (60/70 grade) 0.42%
Plastomeric Thermoplastics (Waste plastic Additive).

21.78.1 Providing and laying semi dense bituminous concrete using crushed aggregates of
2 specified grading, premixed with bituminous binder and filler, transporting the hot mix to
work site, laying with a paver finisher to the required grade, level and alignment, rolling
with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per
MORTH specification clause No. 508 complete in all respects complete as per cum 7041.00
specifications. - using 40-60 TPH capacity HMP with mechanical Paver, Gr-II (30-45mm)
with 5.4 % of modified bitumen binder consisting of 4.97% VG- 30 bitumen (60/70 grade)
0.43% Plastomeric Thermoplastics (Waste plastic Additive).

Page 139 of 350


21.79.1 Stone Matrix Asphalt (SMA) as per section 515 of MORTH 5th Revision: Providing and
laying stone Matrix Asphalt (SMA) using crushed aggregates of specified grading (as per
section 515 of MORTH 5th Revision): premixed with modified bituminous binder
containing Pelletized Cellous fibre at 0.3% (on loose fibre basis) on the weight of total mix
in the batch and filler(Hydrated lime dust @ 2% of weight of aggregates, transporting the hot
mix to work site, Laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, Vibratory and tandem rollers to achieve the desired cum 8621.00
compaction as per MORTH specifications clause no. 515 complete in all respects complete
as per specification.- using 40-60 TPH capacity HMP with mechanical Paver, SMA - 45mm
to 75mm compacted thickness with 5.80% VG- 30 bitumen as per MORTH 5 revision clause
515.

21.79.2 Stone Matrix Asphalt (SMA) as per section 515 of MORTH 5th Revision: Providing and
laying stone Matrix Asphalt (SMA) using crushed aggregates of specified grading (as per
section 515 of MORTH 5th Revision): premixed with modified bituminous binder
containing Pelletized Cellous fibre at 0.3% (on loose fibre basis) on the weight of total mix
in the batch and filler(Hydrated lime dust @ 2% of weight of aggregates, transporting the hot
mix to work site, Laying with a paver finisher to the required grade, level and alignment,
rolling with smooth wheeled, Vibratory and tandem rollers to achieve the desired cum 8619.00
compaction as per MORTH specifications clause no. 515 complete in all respects complete
as per specification. - using 40-60 TPH capacity HMP with mechanical Paver, SMA - 40-50
mm compacted thickness with 5.80% VG- 30 bitumen as per MORTH 5 revision clause 515.

Page No. 173

22.0 22.CONCRETE PAVEMENT

22.1 KSRRB M600-1. Construction of dry lean cement concrete mix CC1:5:10 with OPC
cement @160Kgs, with 25mm and down size graded granite metal coarse aggregate at
0.86cum and fine aggregates @ 0.58cum Sub- base over a prepared sub-grade with (coarse
and fine aggregate conforming to IS: 383) aggregate cement ratio not to exceed 15:1.
Aggregate gradation after blending to be as per Table 600-1, cement content not to be less
than 160 kg/ cum, optimum moisture content to be determined during trial length
construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching cum 3761.00
plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10
tonnes vibratory roller, finishing and curing complete as per specifications.
. MORTH Specification No. 601

22.2.1 KSRRB M600-2. Cement Concrete Pavement :- Construction of un- reinforced, dowel
jointed, plain cement concrete pavement over a prepared sub base with 25mm and down size
graded granite metal coarse aggregate with superplastisizer at 3lts conforming to IS 9103-
1999 reaffirmed 2008, (Coarse and fine aggregate conforming to IS:383) mixed in a
batching and mixing plant as per approved mix design, transported to site, laid with a fixed
form or slip form paver, spread, compacted and finished in a continuous operation including
provision of contraction, expansion, construction and longitudinal joints including groove cum 6708.00
cutting charges, joint filler, separation membrane, sealant primer, joint sealant, debonding
strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and
grades as per drawing complete as per specifications. MORTH Specification No. 602. -
with M30 @ 360 Kg/cum Cement, C.A, 0.69 cum F.A. 0.46 cum

Page 140 of 350


22.2.2 KSRRB M600-2. Cement Concrete Pavement :- Construction of un- reinforced, dowel
jointed, plain cement concrete pavement over a prepared sub base with 25mm and down size
graded granite metal coarse aggregate with superplastisizer at 3lts conforming to IS 9103-
1999 reaffirmed 2008, (Coarse and fine aggregate conforming to IS:383) mixed in a
batching and mixing plant as per approved mix design, transported to site, laid with a fixed
form or slip form paver, spread, compacted and finished in a continuous operation including
provision of contraction, expansion, construction and longitudinal joints including groove cum 7166.00
cutting charges, joint filler, separation membrane, sealant primer, joint sealant, debonding
strip, dowel bar, tie rod, admixtures as approved, curing compound, finishing to lines and
grades as per drawing complete as per specifications. MORTH Specification No. 602. - -
with M40 @ 420 Kg/cum Cement, C.A, 0.67 cum, F.A. 0.44 cum

22.3 KSRRB M600-3. Construction of Rolled Cement Concrete mix 1:4:8 OPC cement
@180kgs, with 25mm and down size graded granite metal coarse aggregate at 0.85cum and
fine aggregates @0.57cum base course with coarse and fine aggregate conforming to IS:383,
aggregate cement ratio 12:1 and minimum cement content of 180kg/ cum, aggregate
gradation to be as per Table 600-4 after blending, mixing in batching plant at optimum
cum 3898.00
moisture content, transporting to site, laying with a paver with electronic sensor, compacting
with 8-10 tonnes smooth wheeled vibratory roller to achieve, the designed flexural strength,
finishing and curing complete as per specifications -

22.4 KSRRB M600- Construction of Base / sub-base of pavement with Lean Concrete
flyash: KSRRB M600-5. Construction of Base sub-base mix 1:5:10 OPC cement
@160kgs, with 25mm and down size graded granite metal coarse aggregate at 0.86cum and
fine aggregates @0.32cum using cement, sand, flyash @ 0.26 and coarse aggregates
proportioned as per table 4 of IRC: 74-1979 and with water content ratio, slump and
compressive strength as defined in the said table, mix prepared in a batching and mixing
plant and compacted with a vibratory roller 8-10 tonnes capacity within the time limit laid cum 3213.00
down vide clause 700.6.3 of IRC:74-1979, construction joints properly formed at the end of
days work, cured for 14 days, all as specified in IRC: 74-1979 and as per approved plans
complete as per specifications (Fly ash content @0.26cum) MORTH Specification No.
Suggestive

Page No. 176


22.5 KSRRB M600-Cement -Flyash concrete pavement: KSRRB M600-Cement -Flyash
concrete pavement KSRRB M600-6. Construction of reinforced, dowel jointed, plain cement
concrete pavement over a prepared sub base with OPC cement design mix M30 at 360 kg
per cum, with 25mm and down size graded granite metal coarse aggregate at 0.69cum and
fine aggregates @0.46cum with superplastisizer at 3lts conforming to IS 9103-1999
Reaffirmed 2008, coarse and fine aggregate conforming to IS: 383, replacing cement by fly
ash to the extent of 15% and sand by 10%, mixed in a batching and mixing plant as per
approved mix design, transported to site, laid with a fixed form or slip form paver, spread, cum 6084.00
compacted and finished in a continuous operation including provision of contraction,
expansion, construction and longitudinal joints including groove cutting charges, joint filler,
separation membrane, sealant primer, joint sealant, debonding strip, dowel bar, tie rod,
admixtures as approved, curing compound, finishing to lines and grades as per drawing
complete as per specifications MORTH Specification No. Suggestive

Page 141 of 350


22.6.1 Cement concrete pavement.Construction of un-reinforced plain cement concrete pavement,
thickness as per design, over a prepared sub base with OPC cement or any other type as per
clause 1051.2.2 design mix M20/M30 , with 25mm and down size graded granite metal
coarse aggregates and fine aggregtes , with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008 , mixed in a concrete mixer of not less than 0.6 cum capacity and
appropriate weigh batcher as per approved mix design, laid in approved fixed side form
work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel
plates including levelling the form work as per drawing). Spreading the concrete with cum 5866.00
shovels, rackers compacted using needle, screed and plate vibrator and finished in a
continuous operation including provision of contraction, expansion, construction and
longitudinal joints including groove cutting charges, joint filler, separation membrane, selant
primer, joint sealant, admixtures as approved, curing compound, finishing to lines and
grades as per drawing complete as per specifications. - M30 (at 360Kg per cum coarse
aggregate @ 0.69cum and fine aggregate @ 0.46cum)

22.6.2 Cement concrete pavement.Construction of un-reinforced plain cement concrete pavement,


thickness as per design, over a prepared sub base with OPC cement or any other type as per
clause 1051.2.2 design mix M20/M30 , with 25mm and down size graded granite metal
coarse aggregates and fine aggregtes , with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008 , mixed in a concrete mixer of not less than 0.6 cum capacity and
appropriate weigh batcher as per approved mix design, laid in approved fixed side form
work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel
plates including levelling the form work as per drawing). Spreading the concrete with cum 5197.00
shovels, rackers compacted using needle, screed and plate vibrator and finished in a
continuous operation including provision of contraction, expansion, construction and
longitudinal joints including groove cutting charges, joint filler, separation membrane, selant
primer, joint sealant, admixtures as approved, curing compound, finishing to lines and
grades as per drawing complete as per specifications. - M20 (at 300Kg per cum coarse
aggregate @ 0.64cum and fine aggregate @ 0.43cum)

22.7 Vaccum de-watering with vaccum pump and suction mat and compaction with skin floater
clubbed with floating disc including cost of generator, HOM of machinery, Screed Sqm 90.00
Vibratory, Power Floater, blade and disc etc., with all lead and lift.
Page No. 177
22.8.1 Providing groove cutting for width of 5mm to 10mm and depth 80mm- 100mm including
cost of cutting machine, generator & HOM of machinery, including cost of blade,coolant
etc., including cleaning of groove & providing sand and hot bitumen fillars, and filler metal
etc., including cost of conveyance of all materials, labour, lead and lift charges and all other Rmt. 115.00
incidental charges as per drawing and as per specifications. - for concrete pavement

22.8.2 Providing groove cutting for width of 5mm to 10mm and depth 80mm- 100mm including
cost of cutting machine, generator & HOM of machinery, including cost of blade,coolant
etc., including cleaning of groove & providing sand and hot bitumen fillars, and filler metal
etc., including cost of conveyance of all materials, labour, lead and lift charges and all other Rmt. 75.00
incidental charges as per drawing and as per specifications. - for asphalt pavement

Page No. 178

23.0 23.GEOSYNTHETIC AND REINFORCED EARTH

23.1 KSRRB M700-1. Construction of sub surface drain 200 mm dia using geotextilestreated
with carbon black with physical properties as given in clause 700.2.2.3 formed in to a stable
network and a planar geocomposites structure, joints wrapped with geotextiles to prevent
ingress of soil, all as per clause 700.2 and approved drawings including excavation and m 565.00
backfilling complete as per specifications.MORTH Specification No. 702

23.2 KSRRB M700-2. Construction of a narrow filter sub- surface drain Narrow Filter Sub-
Surface Drain consisting of porous or perforated pipe laid in narrow trench surrounded by a
geotextiles filter fabric, with a minimum of 450 mm overlap of fabric and installed as per m 669.00
clause 700.2.3 and 300.9.3.5 including excavation and backfilling complete as per
specifications. MORTH Specification No. 702.4

Page 142 of 350


23.3 KSRRB M700-3. Laying Paving Fabric Beneath a Pavement Overlay:- Providing and laying
paving fabric with physical requirements as per Table 704-2 over a tack coat of paving
grade Bitumen 80-100 penetration, laid at the rate of 1 kg per sqm over thoroughly cleaned
and repaired surface to provide a water resistant membrane and crack retarding layer. Paving
fabric to be free of wrinkling and folding and to be laid before cooling of tack coat, Sqm 69.00
brooming and rolling of surface with pneumatic roller to maximise paving fabric contact
with pavement surface complete as per specifications. MORTH Specification No. 703

23.4 KSRRB M700-4. Laying Boulder Apron in Crates of Synthetic Geogrids:- Providing,
preparing and l aying of geogrids crated apron 1 m x 5 m, 600 mm thick including
excavation and backfilling with baffles at 1 metre interval, made with geogrids having
characteristics as per clause 700.4.2, joining sides with connectors/ring staples, top corners
to be tie tensioned, placing of suitable cross interval ties in layers of 300 mm connecting
opposite side with lateral braces and tied with polymer braids to avoid bulging, constructed
as per clause 700.4.3. filled with stone with minimum size of 200 mm and specific gravity cum 4186.00
not less than 2.65, packed with stone spalls, keyed to the foundation recess in case of sloping
ground and laid over a layer of geotextiles to prevent migration of fines, all as per clause
700.4 and laid as per clause 200.5.3.3 and approved design complete as per
specifications.MORTH Specification No. 704

Page No. 180

24.0 24.TRAFFIC SIGNS, MARKINGS & OTHER ROAD APPURTENANCES

24.1 KSRRB 800-1. Painting two coats after filling the surface with synthetic enamel paint in
approved shades on new plastered concrete surfaces, with materials, labour complete as per Sqm 60.00
specifications. MORTH Chapter 8
24.2.1 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Manufacturing, supply and installation
of retro- reflectorised cautionary, mandatory and informatory signboards made out of cube
corner micro prismatic grade sheeting confirming to 900 MM Equilateral triangle type XI
standards of IRC :67:2012 specifications & fixed over 4 mm thick aluminium composite
panel sheet having minimun 0.30 thick aluminium skin on both sides & fixed over a support
frame of 25x25x3 mm MS angle and mounted on 75mm dia OR 75x75x6mm Mild steel
angle of total height 2.70m with clear height of not less than 2.10 m from the ground level to
the bottom of the sign board & 60 cm below ground level. The sign post should be painted
with one coat of red oxide paint and white colour with brands of 30 cm height alternatively
firmly fixed to the ground by means of foundation with M20 grade cement concrete of 45
cm x45 cm x 60 cm including cost & conveyance of all materials, equipment, machinery & No 5185.00
labour with all leads and lifts, loading charges necessary for satisfactory completion of the
work as directed by engineer in charge. 10 years warranty for retro reflective sheeting from
the original sheeting manufacturer as per clause 6.9 in IRC 2012 & a certified copy of three
years outdoor exposure report from an independent test lab for the product offered shall be
obtained from the supplier.

24.2.2 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Manufacturing, supply and installation
of retro- reflectorised cautionary, mandatory and informatory signboards made out of cube
corner micro prismatic grade sheeting confirming to 600 MM Equilateral triangle type XI
standards of IRC :67:2012 specifications & fixed over 4 mm thick aluminium composite
panel sheet having minimun 0.30 thick aluminium skin on both sides & fixed over a support
frame of 25x25x3 mm MS angle and mounted on 75mm dia OR 75x75x6mm Mild steel
angle of total height 2.70m with clear height of not less than 2.10 m from the ground level to
the bottom of the sign board & 60 cm below ground level. The sign post should be painted No 4166.00
with one coat of red oxide paint and white colour with brands of 30 cm height alternatively
firmly fixed to the ground by means of foundation with M20 grade cement concrete of 45
cm x45 cm x 60 cm including cost & conveyance of all materials, equipment, machinery &
labour with all leads and lifts, loading charges necessary for satisfactory completion of the
work as directed by engineer in charge. 10 years warranty for retro reflective sheeting from
the original sheeting manufacturer as per clause 6.9 in IRC 2012 & a certified copy of three
years outdoor exposure report from an independent test lab for the product offered shall be
obtained from the supplier.

Page 143 of 350


24.2.3 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Manufacturing, supply and installation
of retro- reflectorised cautionary, mandatory and informatory signboards made out of cube
corner micro prismatic grade sheeting confirming to 600 MM Circle type XI standards of
IRC :67:2012 specifications & fixed over 4 mm thick aluminium composite panel sheet
having minimun 0.30 thick aluminium skin on both sides & fixed over a support frame of
25x25x3 mm MS angle and mounted on 75mm dia OR 75x75x6mm Mild steel angle of total
height 2.70m with clear height of not less than 2.10 m from the ground level to the bottom of
the sign board & 60 cm below ground level. The sign post should be painted with one coat No 4732.00
of red oxide paint and white colour with brands of 30 cm height alternatively firmly fixed to
the ground by means of foundation with M20 grade cement concrete of 45 cm x45 cm x 60
cm including cost & conveyance of all materials, equipment, machinery & labour with all
leads and lifts, loading charges necessary for satisfactory completion of the work as directed
by engineer in charge. 10 years warranty for retro reflective sheeting from the original
sheeting manufacturer as per clause 6.9 in IRC 2012 & a certified copy of three years
outdoor exposure report from an independent test lab for the product offered shall be
obtained from the supplier.
24.2.4 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Manufacturing, supply and installation
of retro- reflectorised cautionary, mandatory and informatory signboards made out of cube
corner micro prismatic grade sheeting confirming to 600x800 MM type XI standards of
IRC :67:2012 specifications & fixed over 4 mm thick aluminium composite panel sheet
having minimun 0.30 thick aluminium skin on both sides & fixed over a support frame of
25x25x3 mm MS angle and mounted on 75mm dia OR 75x75x6mm Mild steel angle of total
height 2.70m with clear height of not less than 2.10 m from the ground level to the bottom of
the sign board & 60 cm below ground level. The sign post should be painted with one coat No 5486.00
of red oxide paint and white colour with brands of 30 cm height alternatively firmly fixed to
the ground by means of foundation with M20 grade cement concrete of 45 cm x45 cm x 60
cm including cost & conveyance of all materials, equipment, machinery & labour with all
leads and lifts, loading charges necessary for satisfactory completion of the work as directed
by engineer in charge. 10 years warranty for retro reflective sheeting from the original
sheeting manufacturer as per clause 6.9 in IRC 2012 & a certified copy of three years
outdoor exposure report from an independent test lab for the product offered shall be
obtained from the supplier.
24.2.5 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Manufacturing, supply and installation
of retro- reflectorised cautionary, mandatory and informatory signboards made out of cube
corner micro prismatic grade sheeting confirming to 600x450 MM type XI standards of
IRC :67:2012 specifications & fixed over 4 mm thick aluminium composite panel sheet
having minimun 0.30 thick aluminium skin on both sides & fixed over a support frame of
25x25x3 mm MS angle and mounted on 75mm dia OR 75x75x6mm Mild steel angle of total
height 2.70m with clear height of not less than 2.10 m from the ground level to the bottom of
the sign board & 60 cm below ground level. The sign post should be painted with one coat No 4109.00
of red oxide paint and white colour with brands of 30 cm height alternatively firmly fixed to
the ground by means of foundation with M20 grade cement concrete of 45 cm x45 cm x 60
cm including cost & conveyance of all materials, equipment, machinery & labour with all
leads and lifts, loading charges necessary for satisfactory completion of the work as directed
by engineer in charge. 10 years warranty for retro reflective sheeting from the original
sheeting manufacturer as per clause 6.9 in IRC 2012 & a certified copy of three years
outdoor exposure report from an independent test lab for the product offered shall be
obtained from the supplier.
24.2.6 KSRRB M800-2. Retro-Reflectorised Traffic Signs - Manufacturing, supply and installation
of retro- reflectorised cautionary, mandatory and informatory signboards made out of cube
corner micro prismatic grade sheeting confirming to 900 MM octagon stop board type XI
standards of IRC :67:2012 specifications & fixed over 4 mm thick aluminium composite
panel sheet having minimun 0.30 thick aluminium skin on both sides & fixed over a support
frame of 25x25x3 mm MS angle and mounted on 75mm dia OR 75x75x6mm Mild steel
angle of total height 2.70m with clear height of not less than 2.10 m from the ground level to
the bottom of the sign board & 60 cm below ground level. The sign post should be painted No 7564.00
with one coat of red oxide paint and white colour with brands of 30 cm height alternatively
firmly fixed to the ground by means of foundation with M20 grade cement concrete of 45
cm x45 cm x 60 cm including cost & conveyance of all materials, equipment, machinery &
labour with all leads and lifts, loading charges necessary for satisfactory completion of the
work as directed by engineer in charge. 10 years warranty for retro reflective sheeting from
the original sheeting manufacturer as per clause 6.9 in IRC 2012 & a certified copy of three
years outdoor exposure report from an independent test lab for the product offered shall be
obtained from the supplier.

Page 144 of 350


24.3 KSRRB M800-3. Direction and Place Identification Signs upto 0.9 sqm Size Board:-
Manufacturing, supply and installation of retro- reflectorised cautionary, mandatory and
informatory signboards made out of cube corner micro prismatic grade sheeting confirming
to type XI standards of IRC :67:2012 specifications & fixed over 4 mm thick aluminium
composite panel sheet having minimun 0.30 thick aluminium skin on both sides & fixed
over a support frame of 25x25x3 mm MS angle and mounted on 75mm dia OR 75x75x6mm
Mild steel angle of total height 2.70m with clear height of not less than 2.10 m from the
ground level to the bottom of the sign board & 60 cm below ground level. The sign post
should be painted with one coat of red oxide paint and white colour with brands of 30 cm
height alternatively firmly fixed to the ground by means of foundation with M20 grade
cement concrete of 45 cm x45 cm x 60 cm including cost & conveyance of all materials, Sqm 8104.00
equipment, machinery & labour with all leads and lifts, loading charges necessary for
satisfactory completion of the work as directed by engineer in charge. 10 years warranty for
retro reflective sheeting from the original sheeting manufacturer as per clause 6.9 in IRC
2012 & a certified copy of three years outdoor exposure report from an independent test lab
for the product offered shall be obtained from the supplier.

24.4 KSRRB M800-4. Direction and Place Identification Signs with size more than 0.9 sqm
Size Board:-Manufacturing, supply and installation of retro- reflectorised cautionary,
mandatory and informatory signboards made out of cube corner micro prismatic grade
sheeting confirming to type XI standards of IRC :67:2012 specifications & fixed over 4 mm
thick aluminium composite panel sheet having minimun 0.30 thick aluminium skin on both
sides & fixed over a support frame of 25x25x3 mm MS angle and mounted on 75mm dia OR
75x75x6mm Mild steel angle of total height 2.70m with clear height of not less than 2.10 m
from the ground level to the bottom of the sign board & 60 cm below ground level. The sign Sqm 13902.00
post should be painted with one coat of red oxide paint and white colour with brands of 30
cm height alternatively firmly fixed to the ground by means of foundation with M20 grade
cement concrete of 45 cm x45 cm x 60 cm including cost & conveyance of all materials,
equipment, machinery & labour with all leads and lifts, loading charges necessary for
satisfactory completion of the work as directed by engineer in charge. 10 years warranty for
retro reflective sheeting from the original sheeting manufacturer as per clause 6.9 in IRC
2012 & a certified copy of three years outdoor exposure report from an independent test lab
for the product offered shall be obtained from the supplier.
24.5 No
24.6 No
24.7 No
24.8 No
24.8.1 No
24.8.2 No
24.9 No
24.10 Sqm
24.11 Sqm
24.12 Sqm
24.13 Tonne
24.14 Sqm
24.15 Sqm
24.16 Sqm
24.17 Sqm
24.18 cm
24.19 cm
24.20 Sqm
24.21 Sqm
24.22 Sqm
24.23 Sqm
24.24 Sqm
24.25 Nos
24.26 Nos
24.27 Nos
24.28 Nos
24.29 Nos

Page 145 of 350


24.30 m
24.31 m
24.32 m
24.33 m
24.34 m
24.35 m
24.36 m
24.37 m
24.38 m
24.39 Each
24.40 m
24.41 Each
24.42 Each
24.43 m
24.44 m
24.45 m
24.46 Tonne
24.47 Sqm
24.48 Sqm
24.49 Sqm
24.50 Nos
24.51 Nos
24.52 Nos
24.53 Each
24.54 Each
24.55 Each
24.56 Each
24.57 Each

25.0 25.BRIDGES - PILE FOUNDATION

25.1 KSRRB 1100- Bored / Cast-in-situ R.C.C. piles KSRRB 1100-1. Bored / Cast-in-situ
R.C.C. 1000mm dia. piles with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 excluding m 26247.00
reinforcement as per drawings including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH /Chapter 12

25.1.1 KSRRB 1100- Bored / Cast-in-situ R.C.C. piles KSRRB 1100-1. Bored / Cast-in-situ
R.C.C. 1000mm dia. piles with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 excluding m 26491.00
reinforcement as per drawings including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH /Chapter 12

25.1.2 KSRRB 1100- Bored / Cast-in-situ R.C.C. piles KSRRB 1100-1. Bored / Cast-in-situ
R.C.C. 1000mm dia. piles with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 excluding m 27112.00
reinforcement as per drawings including cost of all materials, labour, HOM of machineries
complete as per specifications. MORTH /Chapter 12

25.2 KSRRB 1100-2. Driving cast-in-place vertical R.C.C. 500mm dia. piles with OPC
cement design mix M20 @ 320kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts
confirming to IS9103- 1999 Reaffirmed-2008 excluding reinforcement as per drawings m 8861.00
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTH / Chapter 12

Page 146 of 350


25.2.1 KSRRB 1100-2. Driving cast-in-place vertical R.C.C. 500mm dia. piles with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts
confirming to IS9103- 1999 Reaffirmed-2008 excluding reinforcement as per drawings m 8987.00
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTH / Chapter 12

25.2.2 KSRRB 1100-2. Driving cast-in-place vertical R.C.C. 500mm dia. piles with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts
confirming to IS9103- 1999 Reaffirmed-2008 excluding reinforcement as per drawings m 9043.00
including cost of all materials, labour, HOM of machineries complete as per specifications.
MORTH / Chapter 12

25.3 KSRRB M1100-3.1. Bored cast-in-situ R.C.C. Pile with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, excluding Reinforcement complete as per Drawing and Technical m 5697.00
Specifications and removal of excavated earth with all lifts and lead upto 1000 m complete
as per specifications. A. Pile diametre =750 mm MORTH Specification
No.1100 & 1700

25.4 KSRRB M1100-3.2. Bored cast-in-situ R.C.C. Pile with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, excluding Reinforcement complete as per Drawing and Technical m 9440.00
Specifications and removal of excavated earth with all lifts and lead upto 1000 m complete
as per specifications. B. Pile diametre = 1000 mm MORTH Specification
No.1100, 1600 & 1700

25.5 KSRRB M1100.3.3. Bored cast-in-situ R.C.C. Pile with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, excluding Reinforcement complete as per Drawing and Technical m 12291.00
Specifications and removal of excavated earth with all lifts and lead upto 1000 m complete
as per specifications.- C. Pile diametre = 1200 mm MORTH Specification
No.1100 & 1700

25.6 KSRRB M1100 Driven cast-in-place R.C.C. Pile KSRRB M1100-4.1. Driven cast-in-place
vertical R.C.C. Pile with OPC cement design mix M35 @ 390kgs, with 20mm and down
size graded granite metal coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, excluding m 4627.00
Reinforcement complete as per Drawing and & Technical Specification complete as per
specifications. Pile diametre = 750 mm MORTH Specification No.1100 & 1700

25.7 KSRRB M1100-4.2. Driven cast-in-place vertical R.C.C. Pile with OPC cement design
mix M35 @ 390kgs, with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008, excluding Reinforcement complete as per Drawing and & m 7516.00
Technical Specification complete as per specifications. Pile diametre = 1000 mm MORTH
Specification No.1100 & 1700

25.8 KSRRB M1100-4.3. Driven cast-in-place vertical R.C.C. Pile with OPC cement design
mix M35 @ 390kgs, with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregtes @ 0.45cum, with uperplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008, excluding Reinforcement complete as per Drawing and & Technical
m 10956.00
Specification complete as per specifications. Pile diametre = 1200 mm MORTH
Specification No.1100 & 1700

Page No. 197

Page 147 of 350


25.9 KSRRB M1100-4.4. Driven precast vertical R.C.C. Piles with OPC cement design mix
M35 @ 390kgs, with 20mm and down size graded granite metal coarse aggregates
@0.68cum and fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008, excluding Reinforcement complete as per Drawing and & m 2103.00
Technical Specification complete as per specifications.Pile diametre = 500 mm MORTH
Specification No. 1100 & 1700

25.10 KSRRB M1100-4.5. Driven precast vertical R.C.C. Piles with OPC cement design mix M35
@ 390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, excluding Reinforcement complete as per Drawing and & Technical m 3717.00
Specification complete as per specifications- Pile diametre = 750 mm MORTH
Specification No. 1100 & 1700

25.11 KSRRB M1100-4.6. Driven precast vertical R.C.C. Piles with OPC cement design mix M35
@ 390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, excluding Reinforcement complete as per Drawing and & Technical m 6272.00
Specification complete as per specifications Pile diametre = 1000 mm MORTH
Specification No.1100 & 1700

25.12 KSRRB M1100-4.7. Driven precast vertical R.C.C. Piles with OPC cement design mix M35
@ 390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregtes @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, excluding Reinforcement complete as per Drawing and & Technical m 1369.00
Specification complete as per specifications. Size of pile = 300 mm x 300 mm MORTH
Specification No.1100 & 1700

25.13 KSRRB M1100-4.8. Driven precast vertical R.C.C. Piles with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregtes @
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 m 2387.00
Reaffirmed-2008, excluding Reinforcement complete as per Drawing
and & Technical Specification complete as per specifications. Size of pile = 500 mm x 500
mm MORTH Specification No.1100 & 1700

25.14 KSRRB M1100-4.9. Driven precast vertical R.C.C. Piles with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded
granite metal coarse aggregates @0.68cum and fine aggregtes @
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 m 4702.00
Reaffirmed-2008, excluding Reinforcement complete as per Drawing
and & Technical Specification complete as per specifications. Size of pile = 750 mm x 750
mm MORTH Specification No.1100 & 1700

25.15 KSRRB M1100-5. Driven Vertical Steel Piles as per Drawing and & Technical Specification
complete as per specifications. Section of the pile =H Section steel column 400 x 250 mm m 5757.00
(ISHB Series) MORTH Specification No.1100 & 1900
25.16 KSRRB M1100-6. Driven Vertical Steel Piles as per Drawing and & Technical Specification
complete as per specifications. Section of the pile =H Section steel column 450 x 250 mm m 6497.00
(ISHB Series) MORTH Specification No.1100 & 1900
25.18 KSRRB M1100- Pile Cap KSRRB M1100-8.1. Cement Concrete for Reinforced Concrete in
Pile Cap as per Drawing and Technical Specification complete as per specifications. A. RCC
with OPC cement design mix M20 @ 320kgs, with 20mm and down size graded granite
metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser cum 5717.00
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case-I: Using Concrete Mixer MORTH
Specification No.1100, 1500 & 1700

25.19 KSRRB M1100-8.2. Pile Cap KSRRB M1100-8.1. Cement Concrete for Reinforced
Concrete in Pile Cap as per Drawing and Technical Specification complete as per
specifications A. RCC with OPC cement design mix M20 @ 320kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum, with cum 5574.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case-II: Using Batching
Plant, Transit Mixer and Concrete Pump MORTH Specification No.1100, 1500 & 1700

Page No. 198

Page 148 of 350


25.20 KSRRB M1100-9.1. Cement Concrete for Reinforced Concrete in Pile Cap as per Drawing
and Technical Specification complete as per specifications. B. RCC with OPC cement
design mix M25 @ 340kgs, with 20mm and down size graded granite metal coarse
aggregates @0.7cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts confirming cum 5932.00
to IS9103- 1999 Reaffirmed-2009. Case-I: Using Concrete Mixer MORTH Specification
No.1100, 1500 & 1700

25.21 KSRRB M1100-9.2. KSRRB M1100-9.1. Cement Concrete for Reinforced Concrete in Pile
Cap
as per Drawing and Technical Specification complete as per specifications. B. RCC with
OPC cement design mix M25 @ 340kgs, with 20mm and down size graded granite metal
coarse aggregates @0.7cum and fine aggregtes @ 0.47cum, with superplastisiser @3lts cum 5865.00
confirming to IS9103-1999 Reaffirmed-2009. Case-II: Using Batching Plant, Transit Mixer
and Concrete Pump MORTH Specification No.1100, 1500 & 1700

25.22 KSRRB M1100-10.1. Cement Concrete for Reinforced Concrete in Pile Cap per Drawing
and Technical Specification complete as per specifications. C. RCC with OPC cement
design mix M30 @ 360kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregtes @ 0.46cum, with superplastisiser @3lts cum 6097.00
confirming to IS9103-1999 Reaffirmed-2008. Case-I: Using Concrete Mixer MORTH
Specification No.1100, 1500 & 1700

25.23 KSRRB M1100-10.2. KSRRB M1100-10.1. Cement Concrete for Reinforced Concrete in
Pile
Cap per Drawing and Technical Specification complete as per
specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregtes @ 0.46cum, with cum 6036.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case-II: Using
Batching Plant, Transit Mixer and Concrete Pump MORTH Specification No.1100, 1500 &
1700

25.24 KSRRB M1100-11.1. Cement Concrete for Reinforced Concrete in Pile Cap complete as per
Drawing and Technical Specification complete as per specifications.D. RCC with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded granite metal coarse
aggregates @0.68cum and fine aggregtes @ 0.45cum, with superplastisiser @3lts cum 6341.00
confirming to IS9103-1999 Reaffirmed-2008. Case-I: Using Concrete Mixer MORTH
Specification No.1100, 1500 & 1700

25.25 KSRRB M1100-11.2. -Cement Concrete for Reinforced Concrete in


Pile Cap complete as per Drawing and Technical Specification complete
as per specifications. D. RCC with OPC cement design mix M35 @ 390kgs, with 20mm and
down size graded granite metal coarse aggregates @0.68cum and fine aggregtes @ 0.45cum, cum 6290.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case-II: Using
Batching Plant, Transit Mixer and Concrete Pump MORTH Specification No.1100, 1500 &
1700

Page No. 199


25.26 KSRRB M1100-Levelling course for Pile Cap KSRRB M1100-12. Providing and laying of
PCC M 15 levelling course 100 mm thick below the pile cap complete as per specifications cum 4419.00
MORTH Specification No.1100 & 1700
25.27.2 KSRRB M1100- Supplying, Fitting and Placing un-coated HYSD bar /MS Bar KSRRB
M1100-13. Supplying, Fitting and Placing un-coated TMT bar Reinforcement in Foundation
as per Drawing and Technical Specifications complete as per specifications MORTH Tonne 54653.00
Specification No.1600 - TMT bars Fe 500
25.27.3 KSRRB M1100- Supplying, Fitting and Placing un-coated HYSD bar /MS Bar KSRRB
M1100-13. Supplying, Fitting and Placing un-coated TMT bar Reinforcement in Foundation
as per Drawing and Technical Specifications complete as per specifications MORTH Tonne 55222.00
Specification No.1600 - TMT bars Fe 550
25.28 KSRRB M1100-14. Supplying, fitting and placing un-coated Mild steel reinforcement in
foundation as per drawing and technical specification complete as per specifications Tonne 51368.00
MORTH Specification No.1600

Page 149 of 350


25.29 Trail Bores : Drilling 80mm dia hole through all kinds of soil using casing shoe bit vertical
or inclined up to 10 degree to vertical, as directed includ- ing cost of materials, machineries,
labour, water charges, remaining, collection of wash samples at suitable intervals, logging m 1311.00
and leaving, supplying honne wood core box, fixing casing pipes (excluding cost of casing
pipes etc., complete.
25.30 Trail Bores : Drilling 76mm dia (NX) core hole in soft rock using diamond core bit vertical
or inclined up to 10 degree to vertical, as directed in- cluding cost of materials, machineries,
labour, water charges, collection of core samples, logging and leaving, supplying honne m 2803.00
wood core box including cement grounding (excluding cost of cement for grouting) and re-
drilling in case of collapse of sides etc., complete.
25.31 Trail Bores : Drilling 76 mm dia (NX) core hole in Hard rock using dia- mond core bit
vertical or inclined up to 10 degree to vertical as directed including cost of materials,
machineries, labour, including cement grouting (excluding cost of cement for grouting) and m 5483.00
re-drilling incase of collapse of sides etc., complete.
Page No. 200

26.0 26.BRIDGES - WELL FOUNDATION

26.1 KSRRB M1200- Temporary Island KSRRB M1200-1.1. Providing and Constructing
Temporary Island 16 m diameter for Construction of Well Foundation for 8m dia Well No 112996.00
complete as per specifications. MORTH Specification No. 1200
26.2 KSRRB M1200-1.2. Providing and Constructing Temporary Island 16 m diameter for
Construction of Well Foundation for 8m dia Well complete as per specifications. B.
Assuming depth of water 4.0 m and height of island 4.5m MORTH Specification No. 1200 No 690159.00

26.3 KSRRB M1200-1.3. Providing and Constructing Temporary Island 16 m diameter for
Construction of Well Foundation for 8m dia Well complete as per specifications. C.
Providing and constructing one span service road to reach island location from one pier m 4560.00
location to another pier location- Assuming span length 30 m, width of service road 10 m &
depth of water 1 mMORTH Specification No. 1200
26.4 KSRRB M1200- Providing and Laying Cutting Edge of Mild Steel KSRRB M1200-2.
Providing and Laying Cutting Edge of Mild Steel weighing 40 kg per metre for Well
Foundation complete as per Drawing and Technical Specification complete as per Tonne 71090.00
specifications MORTH Specification No.1200 & 1900
26.5 KSRRB M1200-3.1. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification. MORTH Specification No. 1200,1500 & 1700 -

26.5.1 KSRRB M1200-3.1 i) RCC with OPC cement design mix M20 @ 320kgs, with 20mm
and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 7173.00

26.5.2 KSRRB M1200-3.2 ii) RCC with OPC cement design mix M25 @ 340kgs, with 20mm
and down size graded granite metal coarse aggregates @0.7cum and fine aggregates @
0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 7439.00

26.5.3 KSRRB M1200-3.3. iii) RCC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 7916.00

26.5.4 KSRRB M1200-4.1. i) PCC with OPC cement design mix M15 @ 240kgs, with 40mm
and down size graded granite metal coarse aggregates @0.63cum and fine aggregates @ cum 5398.00
0.42cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
26.5.5 KSRRB M1200-4.2. ii) PCC with OPC cement design mix M20 @ 300kgs, with 40mm
and down size graded granite metal coarse aggregates @0.64cum and fine aggregates @
0.43cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 6183.00

Page No. 202

Page 150 of 350


26.5.6 KSRRB M1200-4.3. iii) RCC with OPC cement design mix M20 @ 320kgs, with 20mm
and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 6600.00

26.5.7 KSRRB M1200-4.4. iv) PCC with OPC cement design mix M25 @ 340kgs, with 40mm
and down size graded granite metal coarse aggregates @0.7cum and fine aggregates @
0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 6777.00

26.5.8 KSRRB M1200-4.5. v) RCC with OPC cement design mix M25 @ 340kgs, with 20mm
and down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ cum 6843.00
0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008
26.5.9 KSRRB M1200-4.6. vi) PCC with OPC cement design mix M30 @ 360kgs, with 40mm
and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 6946.00

26.5.10 KSRRB M1200-4.7. vii) RCC with OPC cement design mix M30 @ 360kgs, with 20mm
and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 7011.00

26.5.11 KSRRB M1200-4.8 viii) RCC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 cum 7281.00

26.5.12 KSRRB M1200-4.9. ix) RCC with OPC cement design mix M40 @ 420kgs, with 20mm
and down size graded granite metal coarse aggregates @0.67cum and fine aggregates @
0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - Using cum 7159.00
Batching Plant, Transit Mixer and Concrete PumpMORTH Specification No.1200,1500 &
1700
26.6 KSRRB M1200-5.1. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe. C. Bottom
Plug: i) PCC with 43 grade cement design mix M20 @ 320kgs, with 40mm and down size
graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with cum 6058.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using
Concrete Mixer. MORTH Specification No.1200,1500 & 1700

26.7 KSRRB M1200-5.2. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe i) PCC
with OPC cement design mix M20 @ 320kgs, with 20mm and down size graded granite
metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser cum 5579.00
@3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II : Using Batching Plant,
Transit Mixer and Crane / Concrete PumpMORTH Specification No.1200,1500 & 1700

Page No. 203


26.8 KSRRB M1200-6.1. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe ii) PCC
with OPC cement design mix M25 @ 340kgs, with 40mm and down size graded granite
metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with superplastisiser cum 6626.00
@3lts confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using Concrete
MixerMORTH Specification No.1200,1500 & 1700

26.9 KSRRB M1200-6.2. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe ii)PCC
with OPC cement design mix M25 @ 340kgs, with 40mm and down size graded granite
metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with superplastisiser cum 6153.00
@3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant,
Transit Mixer and Crane / Concrete Pump MORTH Specification No.1200,1500 &
1700

Page 151 of 350


26.10 KSRRB M1200-7.1. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe. iii) PCC
with OPC cement design mix M30 @ 360kgs, with 20mm and down size graded granite
metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser cum 7464.00
@3lts confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using Concrete
MixerMORTH Specification No.1200,1500 & 1700

26.11 KSRRB M1200-7.2. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe. :PCC with
OPC cement design mix M30 @ 360kgs, with 40mm and down size graded granite metal
coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts cum 6312.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
and Crane / Concrete PumpMORTH Specification No.1200,1500 & 1700

26.12 KSRRB M1200-8.1. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe. iv) PCC
with OPC cement design mix M35 @ 390kgs, with 40mm and down size graded granite
metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser cum 7774.00
@3lts confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using Concrete
MixerMORTH Specification No.1200,1500 & 1700

26.13 KSRRB M1200-8.2. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification Concrete to be placed using tremie pipe :PCC with
OPC cement design mix M35 @ 390kgs, with 40mm and down size graded granite metal
coarse aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @3lts cum 6569.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
and Crane / Concrete PumpMORTH Specification No.1200,1500 & 1700

Page No. 204


26.14 KSRRB M1200-9.1. (i) PCC with OPC cement design mix M20 @ 320kgs, with 40mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Same as cum 5789.00
in bottom plug concrete, excluding cost of forming sump, protective bunds, chiselling
etc.MORTH Specification No.1200,1500 & 1700
26.15.1 D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well Foundation MORTH
Specification No.1200,1500 & 1700 - KSRRB M1200-9.2. (ii) PCC with OPC cement
design mix M25 @ 340kgs, with 40mm and down size graded granite metal coarse cum 6329.00
aggregates @0.7cum and fine aggregates @ 0.47cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008
26.15.2 D. Intermediate Plug - Plain / Reinforced Cement Concrete, in Well Foundation MORTH
Specification No.1200,1500 & 1700 - KSRRB M1200-9.3. (iii) PCC with OPC cement
design mix M30 @ 360kgs, with 40mm and down size graded granite metal coarse cum 7464.00
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008
26.16 E.Top Plug KSRRB M1200-10.1. (i) i) PCC design mix M15 with OPC cement @ 240kgs,
with 40mm and down size graded granite metal coarse aggregates @0.63cum and fine cum 4907.00
aggregates @ 0.42cum MORTH Specification No.1200,1500 & 1700
26.17 KSRRB M1200-10.2. (ii) PCC with OPC cement design mix M20 @ 320kgs, with 20mm
and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 MORTH cum 5647.00
Specification No.1200,1500 & 1700
26.18 KSRRB M1200-10.3. (iii) PCC with OPC cement design mix M25 @ 340kgs, with 40mm
and down size graded granite metal coarse aggregates @0.7cum and fine aggregates @
0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Same as cum 6188.00
item 2100-11.5. excluding formwork MORTH Specification No.1200,1500 & 1700

26.19 KSRRB M1200-10.4. (iv) PCC with OPC cement design mix M30 @ 360kgs, with 40mm
and down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Same as cum 6341.00
item 2100-11.9. excluding formwork MORTH Specification No.1200,1500 & 1700

Page 152 of 350


26.20 "KSRRB M1200-11.1. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification F. Well cap. i) RCC with OPC cement design mix
M20 @ 320kgs, with 20mm and down size graded granite metal coarse aggregates
@0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to cum 7013.00
IS9103-1999 Reaffirmed-2008.Case - I:Using Concrete Mixer” MORTH Specification
No.1200,1500 & 1700

Page No. 205


26.21 "KSRRB M1200-11.2. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification. i) RCC with OPC cement design mix M20 @
320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and
fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 cum 5866.00
Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer and Crane / Concrete
Pump”MORTH Specification No.1200,1500 & 1700

26.22 KSRRB M1200-11.3. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification. i) RCC with OPC cement design mix M20 @
320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and
fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 cum 6241.00
Reaffirmed-2008. Case - I : Using Concrete MixerMORTH Specification No.1200,1500 &
1700

26.23 "KSRRB M1200-11.4. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification. (ii) RCC with OPC cement design mix M25 @
340kgs, with 20mm and down size graded granite metal coarse aggregates @0.7cum and
fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 cum 6098.00
Reaffirmed-2008. (Case - II : Using batching plant, transit mixer and crane /Concrete
”MORTH Specification No.1200,1500 & 1700

26.24 "KSRRB M1200-11.5. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification. (iii) RCC with OPC cement design mix M30 @
360kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and
fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 cum 6630.00
Reaffirmed-2008. Case - I : Using Concrete Mixer”MORTH Specification No.1200,1500 &
1700

26.25 "KSRRB M1200-11.6. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification. :RCC with OPC cement design mix M30 @
360kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and
fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 cum 6227.00
Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer and Crane / Concrete
Pump”MORTH Specification No.1200,1500 & 1700

26.26 "KSRRB M1200-11.7. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification. (iv) RCC with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 cum 6836.00
Reaffirmed-2008. Case - I : Using Concrete Mixer”MORTH Specification No.1200,1500 &
1700

Page No. 206


26.27 "KSRRB M1200-11.8. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification:RCC with OPC cement design mix M35 @
390kgs, with 20mm and down size graded granite metal coarse aggregates @0.68cum and
fine aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 cum 6480.00
Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer and Crane / Concrete
Pump”MORTH Specification No.1200,1500 & 1700

26.28 "KSRRB M1200-12. Plain / Reinforced Cement Concrete, in Well Foundation complete as
per Drawing and Technical Specification (v) RCC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates @0.67cum and
fine aggregates @ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 cum 6703.00
Reaffirmed-2008. Using Btching Plant, Transit Mixer and Concrete Pump”MORTH
Specification No.1200,1500 & 1700

Page 153 of 350


26.29 KSRRB M1200- Sinking of well in sandy soil KSRRB M1200-13.1. Sinking of 6 m external
diameter well (other than pneumatic method of sinking) through all types of strata namely
sandy soil, clayey soil and rock as shown against each case, complete as per drawing and
technical specifications. Depth of sinking is reckoned from bed level complete as per m 1861.00
specifications. (i) Depth below bed level upto 3.0 m. Rate of sinking = 0.50 m per hour
MORTH Specification No. Section 1200

26.30 KSRRB M1200-13.2. Sinking of well in sandy soil KSRRB M1200-13.1. Sinking of 6 m
external diameter well (other than pneumatic method of sinking) through all types of strata
namely sandy soil, clayey soil and rock as shown against each case, complete as per drawing
and technical specifications. Depth of sinking is reckoned from bed level complete as per m 2502.00
specifications. ii) Beyond 3 m upto 10 m depth, Rate of sinking = 0.33 m per hour MORTH
Specification No. Section 1200

26.34 KSRRB M1200-14.1. Sinking of 7 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. A. Sandy Soil, Diameter of well = 7 m 2590.00
m. i) Depth below bed level upto 3.0 m, Rate of sinking = 0.30 m per hour. MORTH
Specification No. Section 1200

26.35 KSRRB M1200-14.2. Sinking of 7 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. A. Sandy Soil, Diameter of well = 7 m 3319.00
m. (ii) Beyond 3 m upto 10 m depth. Rate of sinking = 0.22 m per hour MORTH
Specification No. Section 1200

26.39 KSRRB M1200-15.1. Sinking of 8 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (i) Depth below bed level upto 3.0 m 3143.00
m. Rate of sinking at 0.25 m per hour MORTH Specification No. Section 1200

26.40 KSRRB M1200-15.2.Sinking of 8 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 3799.00
Rate of sinking at 0.20 m per hour MORTH Specification No. Section 1200

Page No. 207


26.44 KSRRB M1200-16.1. Sinking of 9 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications (i) Depth below bed level upto 3.0 m. m 3240.00
Rate of sinking at 0.25 m per hour MORTH Specification No. Section 1200

26.45 KSRRB M1200-16.2. Sinking of 9 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications (ii) Beyond 3 m upto 10 m depth. m 4168.00
Rate of sinking = 0.18 m per hour MORTH Specification No. Section 1200

26.49.1 KSRRB M1200-17.1. Sinking of 10 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. MORTH Specification No. Section m 3687.00
1200 - i) Depth below bed level upto 3.0 m. Rate of sinking = 0.20 m / hour

Page 154 of 350


26.49.2 KSRRB M1200-17.1. Sinking of 10 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. MORTH Specification No. Section m 4456.00
1200 - ii)Beyond 3 m upto 10 m depth. Rate of sinking = 0.17 m/ hour

26.53 KSRRB M1200-18.1. Sinking of 11 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. i) Depth below bed level upto 3.0 m, m 7936.00
Rate of sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.54 KSRRB M1200-18.2. Sinking of 11 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 7877.00
Rate of sinking at 0.13 m per hour. MORTH Specification No. Section 1200

26.58 KSRRB M1200-19.1. Sinking of 12 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. i) Depth below bed level upto 3.0 m, m 17298.00
Rate of sinking at 0.05 m/ hour MORTH Specification No. Section 1200

26.59 KSRRB M1200-19.2. Sinking of 12 m external diameter well ( other than pneumatic method
of sinking ) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 20453.00
Rate of sinking at 0.038 m/hour MORTH Specification No. Section 1200

26.63 KSRRB M1200-20.1. Sinking of Twin D Type well ( other than pneumatic method of
sinking ) through all types of strata namely, sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Overall length = 12 m, Overall m 3863.00
width = 6 m. (i) Depth from bed level upto 3.0 m, Rate of sinking at 0.18 m/ hour MORTH
Specification No. 1200

26.64 KSRRB M1200-20.2. Sinking of Twin D Type well ( other than pneumatic method of
sinking ) through all types of strata namely, sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Overall length = 12 m, Overall m 4219.00
width = 6 m. (ii) Beyond 3 m upto 10 m depth: Rate of sinking at 0.17 m/hour MORTH
Specification No. 1200
Page No. 208
26.68 KSRRB M1200-21.1. Sinking of 6 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications MORTH Specification No.Section m 2502.00
1200 (i) Depth below bed level upto 3.00m, rate of sinking at 0.33m per hour

26.69 KSRRB M1200-21.2. Sinking of 6 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications MORTH Specification No.Section m 5754.00
1200 (ii) Beyond 3 m upto 10 m depth. Rate of sinking = 0.17 m per hour MORTH
Specification No.Section 1200

Page 155 of 350


26.73 KSRRB M1200-22.1. Sinking of 7 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (i) Depth below bed level upto 3.0 m 3319.00
m. Rate of sinking = 0.22 m per hour MORTH Specification No. Section 1200

26.74 KSRRB M1200-22.2. Sinking of 7 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 5630.00
Rate of sinking = 0.17 m per hour MORTH Specification No. Section 1200

26.78 KSRRB M1200-23.1. Sinking of 8 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (i) Depth from bed level upto 3.0 m. m 4056.00
Rate of sinking = 0.18 m/ hour MORTH Specification No. Section 1200

26.79 KSRRB M1200-23.2. Sinking of 8 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 6114.00
Rate of sinking = 0.17 m/ hour MORTH Specification No. Section 1200

26.83 KSRRB M1200-24.1. Sinking of 9 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (i) Depth below bed level upto 3.0 m 4337.00
m. Rate of sinking = 0.17 m per hour MORTH Specification No. Section 1200

26.84 KSRRB M1200-24.2. Sinking of 9 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 6573.00
Rate of sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.88 KSRRB M1200-25.1. Sinking of 10 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (i) Depth below bed level upto 3.0 m 5172.00
m, Rate of sinking = 0.18 m/ hour MORTH Specification No. Section 1200

Page No. 209


26.89 KSRRB M1200-25.2. Sinking of 10 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 6911.00
Rate of sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.93 KSRRB M1200-26.1. Sinking of 11 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. i) Depth from bed level upto 3.0 m. m 8534.00
Rate of sinking = 0.10 m / hour MORTH Specification No. Section 1200

Page 156 of 350


26.94 KSRRB M1200-26.2.Sinking of 11 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth. m 14582.00
Rate of sinking = 0.08 m/ hour MORTH Specification No. Section 1200

26.98 KSRRB M1200-27.1. Sinking of 12 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. i) Depth below bed level upto 3.0 m, m 20370.00
Rate of sinking = 0.04 m / hour MORTH Specification No. Section 1200

26.99 KSRRB M1200-27.2. Sinking of 12 m external diameter well (other than pneumatic method
of sinking) through all types of strata namely sandy soil, clayey soil and rock as shown
against each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. (ii) Beyond 3 m upto 10 m depth, m 33612.00
Rate of sinking = 0.03 m/ hour MORTH Specification No. Section 1200

26.103. KSRRB M1200-28.1. Sinking of Twin D Type Well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. i) Depth below bed level upto 3.0 m 4706.00
m , Rate of sinking = 0.16 m / hour MORTH Specification No. Section 1200

26.104. KSRRB M1200-28.2.Sinking of Twin D Type Well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications (ii) Beyond 3 m upto 10 m depth, m 7623.00
Rate of sinking = 0.15 m/ hour MORTH Specification No. Section 1200

26.107. KSRRB M1200.29. Sinking of 6 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in soft rock strata upto 3 m. m 12180.00
Rate of sinking = 0.25 m per hour MORTH Specification No. Section 1200

26.108. KSRRB M1200.30. Sinking of 7 m external diameter well (other than pneumatic methodof
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in soft rock strata upto 3 m. m 8913.00
Rate of sinking = 0.22 m per hour MORTH Specification No. Section 1200

Page No. 210


26.109. KSRRB M1200.31. Sinking of 8 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in soft rock strata upto 3 m. m 10002.00
Rate of sinking = 0.22 m per hour MORTH Specification No. Section 1200

26.110. KSRRB M1200.32. Sinking of 9m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in soft rock strata upto 3 m. m 11534.00
Rate of sinking = 0.15 m per hour MORTH Specification No. Section 1200

Page 157 of 350


26.111. KSRRB M1200.33. Sinking of 10m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in soft rock strata upto 3 m. m 12693.00
Rate of sinking = 0.14 m/ hour MORTH Specification No. Section 1200

26.112. KSRRB M1200.34. Sinking of 11m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in soft rock strata upto 3 m. m 28164.00
Rate of sinking = 0.06 m / hour MORTH Specification No. Section 1200

26.113. KSRRB M1200.35. Sinking of 12m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in soft rock strata upto 3 m. m 61997.00
Rate of sinking = 0.025 m / hour MORTH Specification No. Section 1200

26.114. KSRRB M1200.36. Sinking of Twin D Type Well (other than pneumatic method of sinking)
through all types of strata namely sandy soil, clayey soil and rock as shown against each
case, complete as per drawing and technical specifications. Depth of sinking is reckoned
from bed level complete as per specifications. Depth in soft rock strata upto 3 m. Rate of m 13663.00
sinking = 0.12 m / hour MORTH Specification No. Section 1200

26.115. KSRRB M1200- Hard Rock KSRRB M1200.37. Sinking of 6 m external diameter well
(other than pneumatic method of sinking) through all types of strata namely sandy soil,
clayey soil and rock as shown against each case, complete as per drawing and technical
specifications. Depth of sinking is reckoned from bed level complete as per specifications. m 11531.00
Depth in hard rock strata upto 3 m. Rate of sinking = 0.17 m per hour MORTH Specification
No. Section 1200
Page No. 211
26.116. KSRRB M1200.38. Sinking of 7 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in hard rock strata upto 3 m. m 14680.00
Rate of sinking = 0.17 m per hour MORTH Specification No. Section 1200

26.117. KSRRB M1200.39. Sinking of 8 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in hard rock strata upto 3 m. m 15244.00
Rate of sinking = 0.17 m per hour MORTH Specification No. Section 1200

26.118. KSRRB M1200.40. Sinking of 9 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in hard rock strata upto 3 m. m 17403.00
Rate of sinking = 0.15 m per hour MORTH Specification No. Section 1200

26.119. KSRRB M1200.41. Sinking of 10 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in hard rock strata upto 3 m. m 18652.00
Rate of sinking = 0.12 m per hour MORTH Specification No. Section 1200

Page 158 of 350


26.120. KSRRB M1200.42. Sinking of 11 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in hard rock strata upto 3 m. m 40879.00
Rate of sinking = 0.05 m/hour MORTH Specification No. Section 1200

26.121. KSRRB M1200.43. Sinking of 12 m external diameter well (other than pneumatic method of
sinking) through all types of strata namely sandy soil, clayey soil and rock as shown against
each case, complete as per drawing and technical specifications. Depth of sinking is
reckoned from bed level complete as per specifications. Depth in hard rock strata upto 3 m. m 86581.00
Rate of sinking = 0.020 m/hour MORTH Specification No. Section 1200

26.122. KSRRB M1200.44. Sinking of Twin D Type Well (other than pneumatic method of sinking)
through all types of strata namely sandy soil, clayey soil and rock as shown against each
case, complete as per drawing and technical specifications. Depth of sinking is reckoned m 19638.00
from bed level complete as per specifications. Depth in hard rock strata upto 3 m. Rate of
sinking = 0.10 m/hour MORTH Specification No. Section 1200
Page No. 212
26.123. KSRRB M1200-45. Pneumatic sinking of wells with equipment of approved design,
drawing and specifications worked by competent and trained personnel and comprising of
compression and decompression chambers, reducers, two air locks separately for men and
plant & materials, arrangement for supply of fresh air to working chambers, check valves,
exhaust valves, shafts made from steel plates of riveted construction not less than 6 mm
thick to withstand an air pressure of 0.50 MPa, controlled blasting of hard rock where
required, staircases and 1 m wide landing platforms with railing, arrangement for cum 58501.00
compression and decompression, electric lighting of 50 V maximum, proper rooms for rest
and medical examinations and compliance with safety precautions as per IS:4138, all as per
clause 1200.7.6 of MORTH Specifications. MORTH Specification No. Section 1200

26.124. KSRRB M1200-46. Sand filling in wells complete as per drawing and technical
cum 2757.00
specifications MORTH Specification No.1207
26.125. KSRRB M1200-47. Providing steel liner 10 mm thick for curbs and 6 mm thick for seining
of wells including fabricating and setting out as per detailed drawing complete as per Tonne 63705.00
specifications MORTH Specification No.1200 & 1900
26.126. KSRRB M1200-Reinforced cement concrete for well curb KSRRB M1200-48.1.
Construction of cement concrete kerb with top and bottom width 115 and 165 mm
respectively, 250 mm high in M-20 grade PCC on M-10 grade foundation 150 mm thick,
foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb lying m 400.00
machine, founation concrete laid manually, all complete as per Clause 400.8 complete as per
spcifications. A. Using Concrete Mixer MORTH Specification No.408

26.127. KSRRB M1200-48.2. Construction of cement concrete kerb with top and bottom width 115
and 165 mm respectively, 250 mm high in M-20 grade PCC on M-10 grade foundation 150
mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb
lying machine, foundation concrete laid manually, all complete as per Clause 400.8 complete m 330.00
as per spcifications. B. Using Concrete Batching and Mixing Plant MORTH Specification
No.408

26.128. KSRRB M1200-49.1. Cast-in-Situ Cement Concrete M 20 Kerb with Channel. Construction
of cement concrete kerb with channel with top and bottom width 115 and 165 mm
respectively, 250 mm high in M-20 grade PCC on M-10 grade foundation 150 mm thick,
kerb channel laid with kerb laying machine, foundation concrete laid manually, all complete m 738.00
as per Clause 400.8 complete as per specifications. A. Using Concrete Mixer MORTH
Specification No.408

26.129. KSRRB M1200-49.2. Cast-in-Situ Cement Concrete M 20 Kerb with Channel. Construction
of cement concrete kerb with channel with top and bottom width 115 and 165 mm
respectively, 250 mm high in M 20 grade PCC on M10 grade foundation 150 mm thick, kerb
channel laid with kerb laying machine, foundation concrete laid manually, all complete as m 633.00
per Clause 400.8 complete as per specifications. B. Using Concrete Batching and Mixing
Plant MORTH Specification No.408

Page No. 213

Page 159 of 350


26.130. Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in 50mm dia holes
1 drilled in hard rock and grouting in CM 1:1 including necessary bending, hooking, cutting
and handling charges complete, including the cost of steel. (MORTH clause 1200). - below Each 1224.00
LWL in open foundation upto 3m.
26.130. Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in 50mm dia holes
2 drilled in hard rock and grouting in CM 1:1 including necessary bending, hooking, cutting
and handling charges complete, including the cost of steel. (MORTH clause 1200). - below Each 1393.00
LWL in open foundation beyond 3m.
26.130. Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in 50mm dia holes
3 drilled in hard rock and grouting in CM 1:1 including necessary bending, hooking, cutting
and handling charges complete, including the cost of steel. (MORTH clause 1200). - for Each 1899.00
well foundation below LWL upto 3m.
26.130. Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m inserted in 50mm dia holes
4 drilled in hard rock and grouting in CM 1:1 including necessary bending, hooking, cutting
and handling charges complete, including the cost of steel. (MORTH clause 1200). - for Each 2575.00
well foundation below LWL beyond 3m.
Page No. 214

27.0 27.BRIDGES - OPEN FOUNDATIONS

27.1 KSRRB M2100- Excavation in Ordinary Soil KSRRB M2100-1.1. Earth work in excavation
for foundation of structures as per drawing and technical specifications, including setting
out, construction of shoring and bracing, removal of stumps and other deleterious matter,
dressing of sides and bottom and backfilling with approved material complete as per cum 123.00
specifications I. Ordinary soil - A . Manual Means (i) Depth upto 3m MORTH Specification
No. 304

27.2 KSRRB M2100-1.2.Excavation in Ordinary Soil KSRRB M2100-1.1. Earth work in


excavation for foundation of structures as per drawing and technical specifications, including
setting out, construction of shoring and bracing, removal of stumps and other deleterious
matter, dressing of sides and bottom and backfilling with approved material complete as per cum 158.00
specifications I. Ordinary soil - A . Manual Means .ii) 3 m to 6 m depth MORTH
Specification No. 304

27.3 KSRRB M2100-1.3.Excavation in Ordinary Soil KSRRB M2100-1.1. Earth work in


excavation for foundation of structures as per drawing and technical specifications, including
setting out, construction of shoring and bracing, removal of stumps and other deleterious
matter, dressing of sides and bottom and backfilling with approved material complete as per cum 211.00
specifications I. Ordinary soil - A . Manual Means (iii ) Above 6 m depth MORTH
Specification No. 304

27.4 “KSRRB M2100-2.1. Earth work in excavation for foundation of structures as perdrawing
and technical specifications, including setting out, construction of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling
with approved material complete as per specifications. B. Mechanical Means (i ) Depth upto cum 48.00
3 m” MORTH Specification No. 304

27.5 “KSRRB M2100-2.2.Earth work in excavation for foundation of structures as perdrawing


and technical specifications, including setting out, construction of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling
with approved material complete as per specifications. B. Mechanical Means (ii ) Depth 3 m cum 55.00
to 6 m” MORTH Specification No. 304

27.6 “KSRRB M2100-2.3.Earth work in excavation for foundation of structures as perdrawing


and technical specifications, including setting out, construction of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling
with approved material complete as per specifications. B. Mechanical Means (i ) Depth upto cum 68.00
3 m” MORTH Specification No. 304 B.Mechanical Means (iii ) Depth above 6 m MORTH
Specification No. 304

Page 160 of 350


27.7 KSRRB M2100- Excavation in Ordinary Rock with blasting KSRRB M2100-3.1. Earth
work in excavation for foundation of structures as per drawing and technical specifications,
including setting out, construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with approved material cum 176.00
complete as per specifications. “II . Ordinary rock - (not requiring blasting) A. Manual
Means. Depth upto 3 m MORTH Specification No. 304

27.8 “KSRRB M2100-3.2. Excavation in Ordinary Rock with blasting KSRRB M2100-3.1. Earth
work in excavation for foundation of structures as per drawing and technical specifications,
including setting out, construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with approved material cum 61.00
complete as per specifications. (ii) Ordinary rock (not requiring blastsing) “ B. Mechanical
Means Depth upto 3m MORTH Specification No. 304

27.9 KSRRB M2100 Excavation in Hard Rock with Blasting KSRRB M2100-4.1. Earth work in
excavation for foundation of structures as perdrawing and technical specifications, including
setting out, construction of shoring and bracing, removal of stumps and other deleterious
matter, dressing of sides and bottom and backfilling with approved material complete as per cum 416.00
specifications. “III. Hard rock - (requiring blasting) A. Manual Means MORTH
Specification No. 304

Page No. 216


27.10 KSRRB M2100 Excavation in Hard Rock without Blasting KSRRB M2100-4.2. Earth work
in excavation for foundation of structures as per drawing and technical specifications,
including setting out, construction of shoring and bracing, removal of stumps and other
deleterious matter, dressing of sides and bottom and backfilling with approved material cum 402.00
complete as per specifications. “III. Hard rock - (blasting prohibited ) A. Mechanical Means
MORTH Specification No. 304

27.11 KSRRB M2100 Excavation in Marshy soil KSRRB 2100-5. Excavation in marshy soil upto
3m depth for foundations of structures as per drawing and technical specifications including
removing the excavated stuff to a lead of 15m., including dewatering , shoring and
shuttering, refilling trenches in 250mm layers, wherever necessary watering and ramming, cum 578.00
including cost of all materials, labour complete as per specifications. MORTH Chapter 12

27.12 KSRRB M2100-5.1. Earth work in excavation for foundation of structures as per drawing
and technical specifications, including setting out, construction of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling cum 417.00
with approved material complete as per specifications. “V. Marshy soil - A. Manual Means
Upto 3 m depth MORTH Specification No. 304
27.13 “KSRRB M2100-5.2. Earth work in excavation for foundation of structures as per drawing
and technical specifications, including setting out, construction of shoring and bracing,
removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling cum 109.00
with approved material complete as per specifications. “V. Marshy soil - B. Mechanical
Means MORTH Specification No. 304
27.14 KSRRB M2100 Filling the foundations KSRRB 2100-6. Filling the foundations trenches
using approved sand as per drawing and technical specifications in 250mm layers, wherever
necessary watering and ramming, including cost of all materials, labour complete as per cum 3004.00
specifications. MORTH Chapter 12
27.15 KSRRB M2100 Back Filling of abutments using wing wall & Returns KSRRB M2100-7.
Earth work in excavation for foundation of structures as per drawing and technical
specifications, including setting out, construction of shoring and bracing, removal of stumps
and other deleterious matter, dressing of sides and bottom and backfilling with approved cum 258.00
material complete as per specifications. VI. Backfilling in Marshy Foundation Pits.”
MORTH Specification No. 304

27.16 KSRRB M2100-8. Filling Annular Space Around Footing in Rock Lean cement concrete M
cum 5398.00
10 mix.
27.17 KSRRB M2100-9. Sand Filling in Foundation Trenches as per Drawing & Technical
cum 2757.00
SpecificationMORTH Specification No. 304
Page No. 217

Page 161 of 350


27.18 KSRRB M2100 PCC 1 KSRRB M2100-10. Plain cement concrete M10 with OPC cement
@ 220kgs, with crushed 40mm and down size graded granite metal coarse aggregates
@0.84cum and fine aggregates @ 0.56cum, in foundation mechanically mixed, placed in cum 5634.00
foundation and compacted by vibration including curing for 14 days complete as per
specifications MORTH Specification No. 2100
27.19 KSRRB M2100-11. Brick Masonry Work in Cement Mortar 1:3 in Foundation complete
excluding Pointing and Plastering as per Drawing and Technical Specifications MORTH cum 6948.00
Specification No. 1300
27.20 KSRRB M2100-11.1. Brick Masonry Work in Cement Mortar 1:3 ( 1 cement : 3 sand ) in
Foundation complete excluding Pointing and Plastering as per Drawing and Technical cum 6206.00
Specifications MORTH Specification No. 1300
27.22 "KSRRB M2100-12.1. Stone Masonry Work in Cement Mortar 1:3 in Foundation complete
as per Drawing and Technical Specifications A. Square Rubble Coursed Rubbie Masonry cum 4058.00
(first sort)”MORTH Specification No. 1405.4
27.23 KSRRB M2100-12.2. Stone Masonry Work in Cement Mortar 1:3 in Foundation complete
as per Drawing and Technical Specifications. B. Random Rubble Masonry( coursed / cum 4022.00
uncoursed) MORTH Specification No. 1405.4
27.24 KSRRB M2100-13. Plain / Reinforced Cement Concrete M15 with OPC cement @ 240kgs,
with 40mm and down size graded granite metal coarse aggregates @0.84cum and fine
aggregates @ 0.56cum in Open Foundation complete as per Drawing and Technical cum 5871.00
Specifications MORTH Specification No. 1500,1700 & 2100
27.25 "KSRRB M2100-14. Plain /Reinforcement Cement Concrete M20 with OPC cement @
300kgs, with 40mm and down size graded granite metal coarse aggregates @0.64cum and
fine aggregates @ 0.43cum, with superplastisiser @3lts confirming to IS9103-1999 cum 5862.00
Reaffirmed-2008, in Open Foundation complete as per Drawing and Technical
Specifications "MORTH Specification No. 1500,1700 & 2100
27.26 "KSRRB M2100-15.1. “KSRRB M2100-14. Plain /Reinforcement Cement Concrete M20
with OPC cement @ 320kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008, in Open Foundation complete as per Drawing cum 6252.00
and Technical Specifications Case - I : Using Concrete Mixer” MORTH Specification No.
1500,1700 & 2100

27.27 "KSRRB M2100-15.2. Plain /Reinforcement Cement Concrete M20 with OPC cement @
320kgs, with 20mm and down size graded granite metal coarse aggregates @0.69cum and
fine aggregates @ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008, in Open Foundation complete as per Drawing and Technical cum 5740.00
Specifications Case - II : With Batching Plant, Transit Mixer and Concrete Pump MORTH
Specification No. 1500,1700 & 2100

Page No. 218


27.28 KSRRB M2100-16.1. Plain / Reinforced Cement Concrete idesign mix M25 with OPC
cement @ 340kgs, with 40mm and down size graded granite metal coarse aggregates
@0.70cum and fine aggregates @ 0..47cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008,Open Foundation complete as per Drawing and Technical cum 6410.00
Specifications D. PCC Grade M-25. Case - I : Using Concrete Mixer MORTH Specification
No. 1500,1700 & 2100

27.29 KSRRB M2100-16.2. Plain / Reinforced Cement Concrete idesign mix M25 with OPC
cement @ 340kgs, with 40mm and down size graded granite metal coarse aggregates
@0.70cum and fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008,Open Foundation complete as per Drawing and Technical cum 6023.00
Specifications Case - II With Batching Plant, Transit Mixer and Concrete PumpMORTH
Specification No.1500,1700 & 2100

27.30 KSRRB M2100-17.1. Plain / Reinforced Cement Concrete idesign mix M25 with OPC
cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates
@0.70cum and fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008,Open Foundation complete as per Drawing and Technical cum 6473.00
Specifications Case - I : Using Concrete Mixer MORTH Specification No. 1500,1700 &
2100

Page 162 of 350


27.31 KSRRB M2100-17.2. Plain / Reinforced Cement Concrete idesign mix M25 with OPC
cement @ 340kgs, with 20mm and down size graded granite metal coarse aggregates
@0.70cum and fine aggregates @ 0.47cum, with superplastisiser @3lts confirming to
IS9103-1999 Reaffirmed-2008,Open Foundation complete as per Drawing and Technical cum 6084.00
Specification Case - II : With Batching Plant, Transit Mixer and Concrete Pump MORTH
Specification No. 1500,1700 & 2100

27.32 KSRRB M2100-18.1. Plain / Reinforced Cement Concrete in Open Foundation with OPC
cement design mix M30 @ 360kgs, with 40mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2010complete as per Drawing and Technical cum 6554.00
Specifications. Case - I : Using Concrete Mixer MORTH Specification No. 1500,1700 &
2100

27.33 KSRRB M2100-18.2. Plain / Reinforced Cement Concrete in Open Foundation with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008 complete as per Drawing and Technical cum 6167.00
Specifications Case - II : With Batching Plant, Transit Mixer and Concrete Pump MORTH
Specification No. 1500,1700 & 2100
Page No. 219
27.34 KSRRB M2100-19.1. Plain / Reinforced Cement Concrete in Open Foundation with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008 complete as per Drawing and Technical cum 6613.00
Specifications. Case - I : Using Concrete Mixer MORTH Specification No. 1500,1700 &
2100

27.35 KSRRB M2100-19.2. Plain / Reinforced Cement Concrete in Open Foundation with OPC
cement design mix M30 @ 360kgs, with 20mm and down size graded granite metal coarse
aggregates @0.69cum and fine aggregates @ 0.46cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008 complete as per Drawing and Technical cum 6227.00
Specifications Case - II : With Batching Plant, Transit Mixer and Concrete Pump MORTH
Specification No. 1500,1700 & 2100

27.36 KSRRB M2100-20.1. Plain / Reinforced Cement Concrete in Open Foundation with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded granite metal coarse
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @3lts cum 6836.00
confirming to IS9103-1999 Reaffirmed-2008. Case - I : Using Concrete Mixer MORTH
Specification No. 1500,1700 & 2100
27.37 KSRRB M2100-20.2. Plain / Reinforced Cement Concrete in Open Foundation with OPC
cement design mix M35 @ 390kgs, with 20mm and down size graded granite metal coarse
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008. case II : With Batching Plant, Transit Mixer cum 6451.00
and Concrete Pump MORTH Specification No. 1500,1700 & 2100

Page No. 220

28.0 28.BRIDGES - SUB-STRUCTURE

28.1 KSRRB M2200- Brick masonry in Substructure KSRRB M2200-1. Brick masonry work in
1:3 in sub-structure complete excluding pointing and plastering, as per drawing and
Technical Specifications complete MORTH Specification No. 1300 & 2200as per cum 11828.00
specifications
28.2 KSRRB M2200-2. Pointing with cement mortar (1:3 ) on brick work in substructure as per
Technical Specifications, complete as per specifications MORTH Specification No. 1300 & Sqm 56.00
2200
28.3 KSRRB M2200-3. Plastering with cement mortar (1:3 ) on brick work in sub-structure as per
Technical Specifications, complete as per specifications MORTH Specification No. 1300 & Sqm 136.00
2200

Page 163 of 350


28.4 KSRRB M2200- Stone masonry in Substructure KSRRB M2200-4.1. Stone masonry work
in cement mortar 1:3 for substructure complete as per drawing and Technical Specifications
complete as per specifications. A. Random Rubble Masonry (uncoursed) MORTH cum 3979.00
Specification No. 1400 & 2200
28.5 KSRRB M2200-4.2. Stone masonry in Substructure KSRRB M2200-4.1. Stone masonry
work in cement mortar 1:3 for substructure complete as per drawing and Technical
Specifications complete as per specifications. B. Coursed rubble masonry (first sort) cum 4046.00
MORTH Specification No. 1400 & 2200
28.6 KSRRB M2200-4.3. Stone masonry in Substructure KSRRB M2200-4.1. Stone masonry
work in cement mortar 1:3 for substructure complete as per drawing and Technical
Specifications complete as per specifications. C. Ashlar masonry ( first sort ) Plain ashlar cum 5006.00
MORTH Specification No. 1400 & 2200
28.7 KSRRB M2200- PCC/RCC KSRRB 2200 Plain / Reinforced cement concrete in sub-
structure complete as per drawing and Technical Specifications complete as per
specifications MORTH Specification No.1500,1700 & 2200 Unit = cum
28.7.1 KSRRB M2200-5.1 M15 with OPC cement @ 240kgs, with 40mm and down size graded
granite metal coarse aggregates @0.63cum and fine aggregates @ 0.42cum a) upto 5mtr cum 6238.00
height
28.7.2 KSRRB M2200-5.2. Design mix M20 with OPC cement @ 300kgs, with 40mm and down
size graded granite metal coarse aggregates @0.64cum and fine aggregates @ 0.43cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, b) upto 5 m height cum 6228.00

28.7.3 KSRRB M2200-5.3. Design mix M25 With OPC cement @ 340kgs, with 40mm and down
size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 c) - i) Upto 5 m height cum 6756.00

Page No. 222


28.7.4 KSRRB M2200-5.4. Design mix M25 @ with OPC cement 340kgs, with 40mm and down
size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - ii) For height above 5 cum 7021.00
m and upto 10 m.
28.7.5 KSRRB M2200-5.5. Dsign mix M25 with OPC cement @ 340kgs, with 40mm and down
size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - iii) For height above cum 7353.00
10 m.
28.7.6 KSRRB M2200-5.6. design mix M30 with OPC cement @ 360kgs, with 40mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - i) upto 5 m height cum 6911.00

28.7.7 KSRRB M2200-5.7.Design mix M30 with OPC cement @ 360kgs, with 40mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 d) PCC Grade M-30 - ii) cum 7182.00
For height above 5 m and upto 10 m.
28.7.8 KSRRB M2200-5.8. Design mix M30 with OPC cement @ 360kgs, with 40mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - iii) For height above cum 7539.00
10 m.
28.7.9 KSRRB M2200-5.9. Design mix M20 with OPC cement @ 320kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - i) Upto 5 m height. cum 6571.00

28.7.10 KSRRB M2200-5.10. Design mix M20 with OPC cement @ 320kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - ii) For height, upto cum 6861.00
10m
28.7.11 KSRRB M2200-5.11. Design mix M20 with OPC cement @ 320kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - iii) For height above cum 7151.00
10 m.

Page 164 of 350


28.7.12 KSRRB M2200-5.12.Design mix M25 with OPC cement @ 340kgs, with 20mm and down
size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - i) Upto 5m height cum 6839.00

Page No. 223


28.7.13 KSRRB M2200-5.13. Design mix M25 with OPC cement @ 340kgs, with 20mm and down
size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - ii)For height, upto cum 7081.00
10m,
28.7.14 KSRRB M2200-5.14.Design mix M25 with OPC cement @ 340kgs, with 20mm and down
size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - iii) For height, above cum 7442.00
10m,
28.7.15 KSRRB M2200-5.15. design mix M30 with OPC cement @ 360kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - i) Upto 5m height, cum 6991.00

28.7.16 KSRRB M2200-5.16. Design mix M30 with OPC cement @ 360kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 g) RCC Grade M-30 - cum 7203.00
ii) For height, upto 10m,
28.7.17 KSRRB M2200-5.17. Design mix M30 with OPC cement @ 360kgs, with 20mm and down
size graded granite metal coarse aggregates @0.69cum and fine aggregates @ 0.46cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - iii) For height, above cum 7505.00
10m,
28.7.18 KSRRB M2200-5.18.Design mix M35 with OPC cement @ 390kgs, with 20mm and down
size graded granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - i) U pto 5m height, cum 7267.00

28.7.19 KSRRB M2200-5.19. Design mix M35 with OPC cement @ 390kgs, with 20mm and down
size graded granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - ii) For height, upto cum 7443.00
10m,
28.7.20 KSRRB M2200-5.20. Design mix M35 with OPC cement @ 390kgs, with 20mm and down
size graded granite metal coarse aggregates @0.68cum and fine aggregates @ 0.45cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 - iii) For height, above cum 7694.00
10m,
28.7.21 PCC grade M15 with OPC cement @ 240kgs, with 40mm and down size graded granite
cum 6368.00
metal coarse aggregates @0.63cum and fine aggregates @ 0.42cum above 5mtr height
28.7.22 PCC grade design mix M20 with OPC cement @ 300kgs, with 40mm and down size graded
granite metal coarse aggregates @0.64cum and fine aggregates @ 0.43cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, above 5mtr height cum 6287.00

Page No. 224


28.8.2 KSRRB M2200- TMT/MS Bar Reinforcement KSRRB M2200-6. Supplying, fitting and
placing TMT bar reinforcement in sub-structure complete as per drawing and Technical
Specifications complete as per specificationsMORTH Specification No.1600 & 2200 - TMT Tonne 54802.00
Bars Fe 500
28.8.3 KSRRB M2200- TMT/MS Bar Reinforcement KSRRB M2200-6. Supplying, fitting and
placing TMT bar reinforcement in sub-structure complete as per drawing and Technical
Specifications complete as per specificationsMORTH Specification No.1600 & 2200 - TMT Tonne 55484.00
Bars Fe 550
28.9 KSRRB M2200-7. Supplying, fitting and placing mild steel reinforcement complete in
substructure as per drawing and Technical Specifications complete as per Tonne 50726.00
specificationsMORTH Specification No.1600 & 2200

Page 165 of 350


28.10 KSRRB M2200- Providing Weep Holes KSRRB M2200-8. Providing weep holes in Brick
masonry / Plain / Reinforced concrete abutment, wing wall / return wall with 100 mm dia
AC pipe, extending through the full width of the structure with slope of 1V :20H towards Nos/ 168.00
drawing foce. Complete as per drawing and Technical Specifications complete as per mtr
specifications MORTH Specification No.2706 & 2200
28.11 KSRRB M2200-8.1. Back filling behind abutment, wing wall and return wall complete as
per drawing and Technical Specification complete as per specifications. A. Granular material cum 524.00
MORTH Specification No. 710.1.4 of IRC:78 & 2200
28.12 KSRRB M2200-8.2. Back filling behind abutment, wing wall and return wall complete as
per drawing and Technical Specification complete as per specifications. B. Sandy material cum 2911.00
MORTH Specification No.710.1.4 of IRC:78 & 2200
28.13 KSRRB M2200- Filter Media KSRRB M2200-9. Providing and laying of Filter media with
granular materials/stone crushed aggregates satisfying the requirements laid down in clause
2500.4.2.2. of MORTH specifications to a thickness of not less than 600 mm with smaller
size towards the soil and bigger size towards the wall and provided over the entire surface
behind abutment, wing wall and return wall to the full height compacted to a firm condition cum 1296.00
complete as per drawing and Technical Specification complete as per specifications
MORTH Specification No. 710.1.4 of IRC:78 & 2200

28.14 KSRRB M2200- Bearings KSRRB M2200-10. Supplying, fitting and fixing in position true
to line and level cast steel rocker bearing conforming to IRC: 83(Pt.-1) section IX and clause
2000.3 of MORTH specifications complete including all accessories as per drawing and Tonne 414.00
Technical Specifications complete as per specifications MORTH Specification No.1000,
2000 & 2200
28.15 KSRRB M2200-11. Supplying, fitting and fixing in position true to line and level forged
steel roller bearing conforming to IRC: 83(Pt.-1) section IX and clause 2000.3 of MORTH
specifications complete including all accessories as per drawing and Technical Tonne 20.00
Specifications complete as per specifications MORTH Specification No.1000, 2000 & 2200

28.16 KSRRB M2200-12. Supplying, fitting and fixing in position true to line and level sliding
plate bearing with PTFE surface sliding on stainless steel complete including all accessories
as per drawing and Technical Specifications and BS: 5400, section 9.1 & 9.2 (for PTFE) and Tonne 1295.00
clause 2000.4 of MORTH Specifications complete as per specifications MORTH
Specification No.2000 & 2200
Page No. 225
28.17 KSRRB M2200-13. Supplying, fitting and fixing in position true to line and level
elastomeric bearing conforming to IRC: 83 (Part-II) section IX and clause 2000.5 of
MORTH specifications complete including all accessories as per drawing and Technical C.C. 1.00
Specifications complete as per specifications MORTH Specification No. 2000 & 2200

28.18 KSRRB M2200-14. Supplying, fitting and fixing in position true to line and level sliding
plate bearing with stainless steel plate sliding on stainless steel plate with mild steel matrix
complete including all accessories as per drawing and Technical Specifications complete as Tonne 1294.00
per specifications MORTH Specification No.2000 & 2200
28.19 KSRRB M2200-15. Supplying, fitting and fixing in position true to line and level POT-
PTFE bearing consisting of a metal piston supported by a disc or unreinforced elastomer
confined within a metal cylinder, sealing rings, dust seals, PTFE surface sliding against
stainless steel mating surface, complete assembly to be of cast steel/fabricated structural
steel, metal and elastomer elements to be as per IRC: 83 part-I & II respectively and other
Tonne 426.00
parts conforming to BS: 5400, section 9.1 & 9.2 and clause 2000.6 of MORTH
Specifications complete as per drawing and approved Technical Specifications complete as
per specifications MORTH Specification No.2000 & 2200

Page No. 226

29.0 29.BRIDGES - CONCRETE SUPERSTRUCTURE

Page 166 of 350


29.1 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.1.1 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7173.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m

29.1.2 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7460.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10
m

29.1.3 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7746.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to
15 m

29.1.4 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7822.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to
20 m

29.1.5 Solid slab super structure KSRRB M2300-1.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 8078.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20
m

29.2 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification - complete as
per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.2.1 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification - complete as
per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7460.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m

Page 167 of 350


29.2.2 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification - complete as
per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7746.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10
m

29.2.3 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification - complete as
per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8033.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15
m

29.2.4 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification - complete as
per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8078.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20
m

29.2.5 T - Beams & slabs KSRRB M2300-1.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification - complete as
per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8335.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008. Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20
m

29.3 Solid slab super structure KSRRB M2300-2.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008 Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700

Page No. 228


29.3.1 Solid slab super structure KSRRB M2300-2.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 6724.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008 Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m -

29.3.2 Solid slab super structure KSRRB M2300-2.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 6992.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008 Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m -

29.3.3 Solid slab super structure KSRRB M2300-2.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7260.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008 Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

Page 168 of 350


29.3.4 Solid slab super structure KSRRB M2300-2.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7506.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008 Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.3.5 Solid slab super structure KSRRB M2300-2.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. A. RCC with OPC cement design mix M20 @ 320kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7771.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008 Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.4 T - Beams & slabs KSRRB M2300-2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700

29.4.1 T - Beams & slabs KSRRB M2300-2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 6992.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m -

29.4.2 T - Beams & slabs KSRRB M2300-2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7260.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.4.3 T - Beams & slabs KSRRB M2300-2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7528.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.4.4 T - Beams & slabs KSRRB M2300-2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7771.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.4.5 T - Beams & slabs KSRRB M2300-2.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. A. RCC - with OPC cement design mix M20 @ 320kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8036.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008. Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump. MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

Page 169 of 350


29.5 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.5.1 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 7441.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m
-

29.5.2 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 7739.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10
m-

29.5.3 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 8037.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to
15 m

29.5.4 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 8123.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to
20 m

29.5.5 Solid slab super structure KSRRB M2300-3.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 8391.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20
m

29.6 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - I : Using
Concrete Mixer MORTH Specification No. 1500,1600 & 1700

Page No. 229


29.6.1 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7739.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - I : Using
Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m

Page 170 of 350


29.6.2 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 8037.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - I : Using
Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

29.6.3 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 8334.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - I : Using
Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.6.4 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 8391.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - I : Using
Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.6.5 T - Beams & slabs KSRRB M2300-3.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 8658.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - I : Using
Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20 m

29.7 Solid slab super structure KSRRB M2300-4.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700

29.7.1 Solid slab super structure KSRRB M2300-4.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 6992.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m

29.7.2 Solid slab super structure KSRRB M2300-4.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 7271.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.7.3 Solid slab super structure KSRRB M2300-4.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 7550.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

Page 171 of 350


29.7.4 Solid slab super structure KSRRB M2300-4.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 7807.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.7.5 Solid slab super structure KSRRB M2300-4.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with
20mm and down size graded granite metal coarse aggregates @0.7cum and fine aggregates cum 8083.00
@ 0.47cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.8 T - Beams & slabs KSRRB M2300-4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum,
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700

29.8.1 T - Beams & slabs KSRRB M2300-4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7271.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m -

29.8.2 T - Beams & slabs KSRRB M2300-4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7550.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.8.3 T - Beams & slabs KSRRB M2300-4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 7829.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.8.4 T - Beams & slabs KSRRB M2300-4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 8083.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.8.5 T - Beams & slabs KSRRB M2300-4.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. B. RCC with OPC cement design mix M25 @ 340kgs, with 20mm and
down size graded granite metal coarse aggregates @0.7cum and fine aggregates @ 0.47cum, cum 8359.00
with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

Page No. 230

Page 172 of 350


29.9 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.9.1 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7650.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m

29.9.2 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7957.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10
m

29.9.3 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 8264.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to
15 m

29.9.4 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 8351.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to
20 m

29.9.5 Solid slab super structure KSRRB M2300-5.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 8626.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20
m

29.10 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.10.1 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7957.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m

Page 173 of 350


29.10.2 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8264.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10
m

29.10.3 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8570.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15
m

29.10.4 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8626.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20
m

29.10.5 T - Beams & slabs KSRRB M2300-5.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8901.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20
m

29.11 Solid slab super structure KSRRB M2300-6.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700

Page No. 231


29.11.1 Solid slab super structure KSRRB M2300-6.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case cum 7177.00
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m

29.11.2 Solid slab super structure KSRRB M2300-6.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case cum 7464.00
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.11.3 Solid slab super structure KSRRB M2300-6.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 7751.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

Page 174 of 350


29.11.4 Solid slab super structure KSRRB M2300-6.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 8014.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.11.5 Solid slab super structure KSRRB M2300-6.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with
20mm and down size graded granite metal coarse aggregates @0.69cum and fine aggregates cum 8298.00
@ 0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.12 T - Beams & slabs KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700

29.12.1 T - Beams & slabs KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7464.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m

29.12.2 T - Beams & slabs KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 7751.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.12.3 T - Beams & slabs KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 8037.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.12.4 T - Beams & slabs KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @ cum 2898.00
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.12.5 T - Beams & slabs KSRRB M2300-6.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. C. RCC with OPC cement design mix M30 @ 360kgs, with 20mm and
down size graded granite metal coarse aggregates @0.69cum and fine aggregates @
0.46cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case - cum 8581.00
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

Page 175 of 350


29.13 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.13.1 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 7817.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height upto 5 m -

29.13.2 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 8135.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height 5 m to 10 m

29.13.3 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 8454.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height 10 m to 15 m

29.13.4 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 8566.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height 15 m to 20 m

29.13.5 Solid slab super structure KSRRB M2300-7.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 8854.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height above 20 m

29.14 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - I :
Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

Page No. 232


29.14.1 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 8135.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - I :
Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m -

Page 176 of 350


29.14.2 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 8454.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - I :
Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

29.14.3 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 8773.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - I :
Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.14.4 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 8854.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - I :
Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.14.5 T - Beams & slabs KSRRB M2300-7.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 9141.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - I :
Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20 m

29.15 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.15.1 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 9092.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height upto 5 m

29.15.2 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 9730.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height 5 m to 10 m

29.15.3 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 10367.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height 10 m to 15 m

Page 177 of 350


29.15.4 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 10579.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height 15 m to 20 m

29.15.5 Box girder & Balanced cantilever KSRRB M2300-7.3. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 11153.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 -
Height above 20 m

29.16 Solid slab super structure KSRRB M2300-8.1. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700

29.16.1 Solid slab super structure KSRRB M2300-8.1. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 7351.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height upto 5 m

29.16.2 Solid slab super structure KSRRB M2300-8.1. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 7650.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 5 m to 10 m -

29.16.3 Solid slab super structure KSRRB M2300-8.1. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 7949.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.16.4 Solid slab super structure KSRRB M2300-8.1. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 8226.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.16.5 Solid slab super structure KSRRB M2300-8.1. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine cum 8522.00
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height above 20 m

Page No. 233

Page 178 of 350


29.17 T - Beams & slabs KSRRB M2300-8.2. Furnishing and Placing Reinforced/ Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700

29.17.1 T - Beams & slabs KSRRB M2300-8.2. Furnishing and Placing Reinforced/ Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 7650.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m -

29.17.2 T - Beams & slabs KSRRB M2300-8.2. Furnishing and Placing Reinforced/ Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 7949.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.17.3 T - Beams & slabs KSRRB M2300-8.2. Furnishing and Placing Reinforced/ Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 8248.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.17.4 T - Beams & slabs KSRRB M2300-8.2. Furnishing and Placing Reinforced/ Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 8522.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.17.5 T - Beams & slabs KSRRB M2300-8.2. Furnishing and Placing Reinforced/ Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs, with 20mm
and down size graded granite metal coarse aggregates @0.68cum and fine aggregates @ cum 8818.00
0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008, Case - II
: Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.18 Box girder & Balanced cantilever KSRRB M2300-8.3. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700

29.18.1 Box girder & Balanced cantilever KSRRB M2300-8.3. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- cum 8547.00
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height upto 5 m -

Page 179 of 350


29.18.2 Box girder & Balanced cantilever KSRRB M2300-8.3. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- cum 9146.00
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

29.18.3 Box girder & Balanced cantilever KSRRB M2300-8.3. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- cum 9744.00
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.18.4 Box girder & Balanced cantilever KSRRB M2300-8.3. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- cum 10297.00
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.18.5 Box girder & Balanced cantilever KSRRB M2300-8.3. Furnishing and Placing Reinforced/
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. D. RCC / PSC with OPC cement design mix M35 @ 390kgs,
with 20mm and down size graded granite metal coarse aggregates @0.68cum and fine
aggregates @ 0.45cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- cum 10889.00
2008, Case - II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH
Specification No. 1500,1600 & 1700 - Height above 20 m

29.19 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.19.1 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 8803.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m
-

29.19.2 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 8995.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10
m

Page No. 234

Page 180 of 350


29.19.3 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 9317.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to
15 m

29.19.4 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 9640.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to
20 m

29.19.5 Solid slab super structure KSRRB M2300-9.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 9962.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case
- I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20
m

29.20 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with 20mm and
down size graded granite metal coarse aggregates @0.67cum and fine aggregates @
0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700

29.20.1 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with 20mm and
down size graded granite metal coarse aggregates @0.67cum and fine aggregates @ cum 8451.00
0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m -

29.20.2 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with 20mm and
down size graded granite metal coarse aggregates @0.67cum and fine aggregates @ cum 8751.00
0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10
m

29.20.3 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with 20mm and
down size graded granite metal coarse aggregates @0.67cum and fine aggregates @ cum 9052.00
0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15
m

29.20.4 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with 20mm and
down size graded granite metal coarse aggregates @0.67cum and fine aggregates @ cum 9352.00
0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20
m

Page 181 of 350


29.20.5 T - Beams & slabs KSRRB M2300-9.2. Furnishing and Placing Reinforced / Prestressed
cement concrete in super-structure as per drawing and Technical Specification complete as
per specifications. E. PSC with OPC cement design mix M40 @ 420kgs, with 20mm and
down size graded granite metal coarse aggregates @0.67cum and fine aggregates @ cum 9652.00
0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed- 2008, Case -
I : Using Concrete Mixer MORTH Specification No. 1500,1600 & 1700 - Height above 20
m

29.21 Solid slab super structure KSRRB M2300-10.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. RCC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700

29.21.1 Solid slab super structure KSRRB M2300-10.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. RCC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 7645.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height upto 5 m -

29.21.2 Solid slab super structure KSRRB M2300-10.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. RCC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 7941.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 5 m to 10 m

29.21.3 Solid slab super structure KSRRB M2300-10.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. RCC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 8249.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 10 m to 15 m

29.21.4 Solid slab super structure KSRRB M2300-10.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. RCC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 8557.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height 15 m to 20 m

29.21.5 Solid slab super structure KSRRB M2300-10.1. Furnishing and Placing Reinforced /
Prestressed cement concrete in super-structure as per drawing and Technical Specification
complete as per specifications. RCC with OPC cement design mix M40 @ 420kgs, with
20mm and down size graded granite metal coarse aggregates @0.67cum and fine aggregates cum 8865.00
@ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case -
II : Using Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No.
1500,1600 & 1700 - Height above 20 m

29.22 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications.
RCC with OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, with
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700

Page No. 235

Page 182 of 350


29.22.1 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications.
RCC with OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, with cum 7941.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height upto 5 m

29.22.2 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications.
RCC with OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, with cum 8249.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height 5 m to 10 m

29.22.3 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications.
RCC with OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, with
cum 8557.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height 10 m to 15 m

29.22.4 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications.
RCC with OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, with cum 8865.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height 15 m to 20 m

29.22.5 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-10.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications.
RCC with OPC cement design mix M40 @ 420kgs, with 20mm and down size graded
granite metal coarse aggregates @0.67cum and fine aggregates @ 0.44cum, with cum 9173.00
superplastisiser @3lts confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using
Batching Plant, Transit Mixer & Concrete Pump MORTH Specification No. 1500,1600 &
1700 - Height above 20 m

29.23 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-10.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. RCC with OPC cement
design mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
& Concrete Pump MORTH Specification No. 1500,1600 & 1700

Page 183 of 350


29.23.1 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-10.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. RCC with OPC cement
design mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser @3lts cum 8865.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
& Concrete Pump MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m

29.23.2 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-10.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. RCC with OPC cement
design mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser @3lts cum 9481.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
& Concrete Pump MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10 m -

29.23.3 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-10.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. RCC with OPC cement
design mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser @3lts cum 10098.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
& Concrete Pump MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.23.4 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-10.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. RCC with OPC cement
design mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser @3lts cum 10714.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
& Concrete Pump MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.23.5 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-10.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. RCC with OPC cement
design mix M40 @ 420kgs, with 20mm and down size graded granite metal coarse
aggregates @0.67cum and fine aggregates @ 0.44cum, with superplastisiser @3lts cum 11330.00
confirming to IS9103-1999 Reaffirmed-2008 Case - II : Using Batching Plant, Transit Mixer
& Concrete Pump MORTH Specification No. 1500,1600 & 1700 - Height above 20 m

29.24 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates @0.67cum and
fine aggregates @ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700

29.24.1 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates @0.67cum and cum 7509.00
fine aggregates @ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height upto 5 m -

Page 184 of 350


29.24.2 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates @0.67cum and cum 7818.00
fine aggregates @ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height 5 m to 10 m

29.24.3 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates @0.67cum and cum 8126.00
fine aggregates @ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height 10 m to 15 m

29.24.4 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates @0.67cum and cum 8434.00
fine aggregates @ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height 15 m to 20 m

29.24.5 Solid slab / voided slab super -structure KSRRB M2300-11.1. Furnishing and Placing
Reinforced / Prestressed cement concrete in super-structure as per drawing and Technical
Specification complete as per specifications. F. PSC with OPC cement design mix M40 @
420kgs, with 20mm and down size graded granite metal coarse aggregates @0.67cum and cum 8742.00
fine aggregates @ 0.44cum, with superplastisiser @3lts confirming to IS9103-1999
Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700 - Height above 20 m

29.25 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M45 @ 440kgs, with 20mm and down size graded
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification
No. 1500,1600 & 1700

Page No. 236


29.25.1 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M45 @ 440kgs, with 20mm and down size graded cum 8125.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification
No. 1500,1600 & 1700 - Height upto 5 m

29.25.2 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M45 @ 440kgs, with 20mm and down size graded cum 8441.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification
No. 1500,1600 & 1700 - Height 5 m to 10 m

29.25.3 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M45 @ 440kgs, with 20mm and down size graded cum 8758.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification
No. 1500,1600 & 1700 - Height 10 m to 15 m

Page 185 of 350


29.25.4 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M45 @ 440kgs, with 20mm and down size graded cum 9075.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification
No. 1500,1600 & 1700 - Height 15 m to 20 m

29.25.5 T - Beams & slabs including launching of precast girder by launching truss upto 40m span
KSRRB M2300-11.2. Furnishing and Placing Reinforced / Prestressed cement concrete in
super-structure as per drawing and Technical Specification complete as per specifications. F.
PSC with OPC cement design mix M45 @ 440kgs, with 20mm and down size graded cum 9392.00
granite metal coarse aggregates @0.66cum and fine aggregates @ 0.44 cum, with
superplastisiser @4lts confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification
No. 1500,1600 & 1700 - Height above 20 m

29.26 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-11.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded granite metal coarse
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700

29.26.1 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-11.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded granite metal coarse cum 9075.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height upto 5 m

29.26.2 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-11.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded granite metal coarse cum 9709.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height 5 m to 10 m

29.26.3 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-11.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded granite metal coarse cum 10342.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height 10 m to 15 m

29.26.4 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-11.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded granite metal coarse cum 10976.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height 15 m to 20 m

29.26.5 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-11.3.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. F. PSC with OPC
cement design mix M45 @ 440kgs, with 20mm and down size graded granite metal coarse
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts cum 11609.00
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height above 20 m

Page 186 of 350


29.27 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-12.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. G. PSC with OPC
cement design mix M50 @ 450kgs, with 20mm and down size graded granite metal coarse
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700

29.27.1 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-12.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. G. PSC with OPC
cement design mix M50 @ 450kgs, with 20mm and down size graded granite metal coarse cum 9138.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height upto 5 m -

29.27.2 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-12.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. G. PSC with OPC
cement design mix M50 @ 450kgs, with 20mm and down size graded granite metal coarse cum 9781.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height 5 m to 10 m

29.27.3 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-12.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. G. PSC with OPC
cement design mix M50 @ 450kgs, with 20mm and down size graded granite metal coarse cum 10424.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height 10 m to 15 m

29.27.4 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-12.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. G. PSC with OPC
cement design mix M50 @ 450kgs, with 20mm and down size graded granite metal coarse cum 10745.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height 15 m to 20 m

29.27.5 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-12.
Furnishing and Placing Reinforced / Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. G. PSC with OPC
cement design mix M50 @ 450kgs, with 20mm and down size graded granite metal coarse cum 11067.00
aggregates @0.66cum and fine aggregates @ 0.44 cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed- 2008 MORTH Specification No. 1500,1600 & 1700
- Height above 20 m

29.28 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-13.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. H. PSC with OPC
cement design mix M55 @ 450kgs, with 20mm and down size graded granite metal coarse
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700

Page No. 237


29.28.1 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-13.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. H. PSC with OPC
cement design mix M55 @ 450kgs, with 20mm and down size graded granite metal coarse cum 9205.00
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700
- Height upto 5 m

Page 187 of 350


29.28.2 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-13.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. H. PSC with OPC
cement design mix M55 @ 450kgs, with 20mm and down size graded granite metal coarse cum 9853.00
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700
- Height 5 m to 10 m

29.28.3 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-13.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. H. PSC with OPC
cement design mix M55 @ 450kgs, with 20mm and down size graded granite metal coarse cum 10501.00
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700
- Height 10 m to 15 m

29.28.4 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-13.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. H. PSC with OPC
cement design mix M55 @ 450kgs, with 20mm and down size graded granite metal coarse cum 10825.00
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700
- Height 15 m to 20 m

29.28.5 Cast-in-situ box girder, segmental construction & balanced cantilever KSRRB M2300-13.
Furnishing and Placing Reinforced/ Prestressed cement concrete in super-structure as per
drawing and Technical Specification complete as per specifications. H. PSC with OPC
cement design mix M55 @ 450kgs, with 20mm and down size graded granite metal coarse cum 11149.00
aggregates @0.68cum and fine aggregates @ 0.45cum, with superplastisiser @4lts
confirming to IS9103-1999 Reaffirmed-2008 MORTH Specification No. 1500,1600 & 1700
- Height above 20 m

29.29 KSRRB M2300 - TMT bar reinforcement KSRRB M2300-14. Supplying, fitting and placing
TMT bar reinforcement in super-structure complete as per drawing and technical
specifications complete as per specifications MORTH Specification No. 1600

26.29.2 KSRRB M2300 - TMT bar reinforcement KSRRB M2300-14. Supplying, fitting and placing
TMT bar reinforcement in super-structure complete as per drawing and technical
specifications complete as per specifications MORTH Specification No. 1600 - TMT Bars Tonne 55693.00
Fe 415
26.29.3 KSRRB M2300 - TMT bar reinforcement KSRRB M2300-14. Supplying, fitting and placing
TMT bar reinforcement in super-structure complete as per drawing and technical
specifications complete as per specifications MORTH Specification No. 1600 - TMT Bars Tonne 56375.00
Fe 415
29.30 KSRRB M2300 - High tensile wires KSRRB M2300-15. High tensile steel wires / strands
including all accessories for stressing, stressing operations and grouting complete as per
drawing and Technical Specifications complete as per specifications MORTH Specification Tonne 176327.00
No. 1800
Page No. 238

30.0 30.BRIDGES - RIVER TRAINING WORKS AND PROTECTION WORKS

30.1 KSRRB M2500-1.1. Providing and laying boulders apron on river bed for protection against
scour with stone boulders weighing not less than 40 kg each complete as per drawing and
Technical specification complete as per specifications. A. Boulder Laid Dry Without Wire cum 1375.00
Crates MORTH Specification No. 2503
30.2 “KSRRB M2500-1.2. Providing and laying of boulder apron laid in wire crates made with
4mm dia GI wire conforming to IS: 280 & IS:4826 in 100mm x 100mm mesh (weaved
diagonally) including 10% extra for laps and joints laid with stone boulders weighing not cum 2089.00
less than 40 kg each complete as per specifications. B. Boulder Apron Laid in Wire Crates”
MORTH Specification No. 2503

Page 188 of 350


30.3 KSRRB M2500-Cement concrete blocks KSRRB M2500-2. Providing and laying of apron
with cement concrete blocks of size 0.5x0.5x0.5 m cast in-situ and made with nominal mix
of M- 15 grade cement concrete with a minimum cement content of 240 kg / cum as per cum 5349.00
IRC: 21-2000 complete as per specifications MORTH Specification No. 2503

30.4 KSRRB M2500- Pitching KSRRB M2500-3. Providing and laying Filter material
underneath pitching in slopes complete as per drawing and Technical specification MORTH cum 1453.00
Specification No. 2504
30.5 KSRRB M2500-4.1. Providing and laying Pitching on slopes laid over prepared filter media
including boulder apron laid dry in front of toe of embankment complete as per drawing and
Technical specifications A. Stone / Boulder MORTH Specification No. 2504 cum 1375.00

30.6 KSRRB M2500-4.2. Providing and laying Pitching on slopes laid over prepared filter media
including boulder apron laid dry in front of toe of embankment complete as per drawing and
Technical specifications complete as per specifications. B. Cement Concre cum 5349.00

30.7 KSRRB M2500-Flooring with Rubble Stone KSRRB M2500-5.1. Providing and laying
Flooring complete as per drawing and Technical specifications laid over cement concrete
bedding complete as per specifications. A. Rubble stone laid in cement mortar 1:3 MORTH cum 4561.00
Specification No. 2505
30.8 “KSRRB M2500-5.2. Providing and laying Flooring complete as per drawing and Technical
specifications laid over cement concrete bedding complete as per specifications. B. Cement
Concrete Blocks Grade M-15" MORTH Specification No. 2505 cum 6040.00

30.9 KSRRB M2500-6. Dry rubble flooring Construction of dry rubble flooring at cross drainage
works for relatively less important works complete as per specifications MORTH cum 1708.00
Specification No. 2506
Page No. 240
30.10 KSRRB M2500- Geotextile filter KSRRB M2500-7. Laying of a geotextile filter between
pitching and embankment slopes on which pitching is laid to prevent escape of the
embankment material through the voids of the stone pitching / cement concrete blocks as Sqm 123.00
well as to allow free movement of water without creating any uplift head on the pitching
complete as per specifications MORTH Specification No. 700 & 2504
30.12 KSRRB M2500- Curtain Wall KSRRB M2500-9.Curtain wall complete as per drawing and
Technical Specifications. A. Stone masonry in cement mortar (1:3) MORTH Specification cum 3908.00
No. 2507.2
30.13 KSRRB M2500-10.Curtain wall complete as per drawing and Technical Specifications. B.
cum 5213.00
Cement Concrete Grade M-15 MORTH Specification No. 2507.2
30.14 KSRRB M2500- Flexible Apron KSRRB M2500-11. Construction of flexible apron 1 m
thick comprising of loose stone boulders weighing not less than 40 kg beyond curtain wall cum 1443.00
complete as per specifications MORTH Specification No. 2507.2
30.15 KSRRB M2500- Gabian Structure KSRRB M2500.12. Providing and construction of a
gabian structure for retaining earth with segments of wire crates of size 7 m x 3 m x 0.6 m
each divided into 1.5 m compartments by cross netting, made from 4 mm galvanised steel
wire at 32 kg per 10 sqm having minimum tensile strength of 300 Mpa conforming to IS:280
and galvanizing coating conforming to IS:4826, woven into mesh with double twist, mesh cum 3210.00
size not exceeding 100 x 100 mm, filled with boulders with least dimension of 200 mm, all
loose ends to be tied with 4 mm galvanised steel wire complete as per specifications
MORTH Specification No. 2503.3

30.16 KSRRB M2500-13 Gabian Structure for Erosion Control, River Training Works and
Protection works Providing and constructing gabian structures for erosion control, river
training works and protection works with wire crates of size 2 m x 1 m x 0.3 m each divided
into 1m compartments by cross netting, made from 4 mm galvanised steel wire @ 32 kg per
10 sqm having minimum tensile strength of 300 Mpa conforming to IS:280 and galvanizing
cum 5728.00
coating conforming to IS:4826, woven into mesh with double twist, mesh size not exceeding
100 mm x 100 mm, filled with boulders with least dimension of 200 mm, all loose ends to
be securely tied with 4 mm galvanised steel wire complete as per specifications MORTH
Specification No. 2503.3

Page No. 241

Page 189 of 350


31.0 31.EXPANSION JOINTS

31.1 KSRRB M2600- Expansion Joints KSRRB M2600-1. Providing and laying a burried
expansion joint, expansion gap being 20 mm, covered with 12 mm thick, 200 mm wide
galvanised weldable structural steel plate as per IS: 2062, placed symmetrical to centre line
of the joint, resting freely over the top surface of the deck concrete, welding of 8 mm dia. m 1395.00
100 mm long galvanised nails spaced 300 mm c/c along the centre line of the plate, all as
specified in clause 2600.4 MORTH Specification No. 2604

31.2 KSRRB M2600- Filler Joint KSRRB M2600-2. (i) Providing & fixing 2 mm thick
corrugated copper plate in expansion joint complete as per drawing & Technical m 2770.00
Specification complete as per specifications MORTH Specification No. 2605
31.3 KSRRB M2600-3. (ii) Providing & fixing 20 mm thick compressible fibre board in
expansion joint complete as per drawing & Technical Specification complete as per m 139.00
specifications MORTH Specification No. 2605
31.4 KSRRB M2600-4. (iii)Providing and fixing in position 20 mm thick premoulded joint filler
in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a
horizontal movement upto 20 mm, covered with sealant complete as per drawing & m 176.00
Technical Specification MORTH Specification No. 2605
31.5 KSRRB M2600-5.(iv) Providing and filling joint sealing compound as per drawings and
technical specifications with coarse sand and 6 per cent bitumen by weight complete as per m 23.00
specifications MORTH Specification No. 2605
31.6 KSRRB M2600- Asphaltic Plug Joint KSRRB M2600-6. Providing and laying of asphaltic
plug joint to provide for horizontal movement of 25 mm and vertical movement of 2 mm,
depth of joint varying from 75 mm to 100 mm, width varying from 500 mm to 750 mm (in
traffic direction), covered with a closure plate of 200mm x 6mm of weldable structural steel
conforming to IS: 2062, asphaltic plug to consist of polymer modified bitumen binder,
m 1163.00
carefully selected single size aggregate of 12.5 mm nominal size and a heat resistant foam
caulking/ backer rod, all as per approved drawings and specifications, complete as per
specifications MORTH Specification No. 2600

31.7 KSRRB M2600- Elastomeric Slab Seal Expansion Joint KSRRB M2600-7. Providing and
laying of an elastomeric slab steel expansion joint, catering to right or skew (less than 20
deg., moderately curved with maximum horizontal movement upto 50 mm, complete as per
approved drawings and standard specifications to be installed by the manufacturer/supplier
or their authorised representative ensuring compliance to the manufacturer’s instructions for m 17325.00
installation and clause 2600.6 of MORTH specifications for road & bridge works complete
as per specifications. MORTH Specification No. 2606

Page No. 243


31.8 KSRRB M2600- Compression Seal Joint KSRRB M2600-8. Providing and laying of
compression seal joint consisting of steel armoured nosing at two edges of the joint gap
suitably anchored to the deck concrete and a preformed chloroprene elastomer or closed cell
foam joint sealer compressed and fixed into the joint gap with special adhesive binder to m 20114.00
cater for a horizontal movement upto 40 mm and vertical movement of 3 mm complete as
per specifications MORTH Specification No. 2600

31.9 KSRRB M2600- Strip Seal Expansion Joint KSRRB M2600-9. Providing and laying of a
strip seal expansion joint catering to maximum horizontal movement upto 70 mm, complete
as per approved drawings and standard specifications to be installed by the
manufacturer/supplier or their authorised representative ensuring compliance to the m 16860.00
manufacturer’s instructions for installation complete as per specifications MORTH
Specification No. 2607

Page 190 of 350


31.10 KSRRB M2600- Modular Strip/ Box Seal Joint KSRRB M2600-10. Providing and laying of
a modular strip Box seal expansion joint including anchorage catering to a horizontal
movement beyond 70 mm and upto 140mm, complete as per approved drawings and
standard specifications to be installed by the manufacturer/supplier or their authorised m 7447.00
representative ensuring compliance to the manufacturer’s instructions for installation
complete as per specifications MORTH Specification No. 2600

31.11 KSRRB M2600-11 Providing and laying of a modular strip box seal expansion joint catering
to a horizontal movement beyond 140mm and upto 210mm, complete as per approved
drawings and standard specifications to be installed by the manufacturer/supplier or their
authorised representative ensuring compliance to the manufacturer’s instructions for m 8965.00
installation. complete as per specifications. MORTH Specification No. 2600

Page No. 244

32.00 32.BRIDGES - WEARING COAT & APPURTENANCES

32.1 KSRRB M2700- Mastic Asphalt KSRRB M2700-1. Providing and laying 12 mm thick
mastic asphalt wearing course on top of deck slab excluding prime coat with paving grade
bitumen meeting the requirements given in table 500-29, prepared by using mastic cooker
and laid to required level and slope after cleaning the surface, including providing antiskid
surface with bitumen precoated fine grained hard stone chipping of 9.5 mm nominal size at
the rate of 0.005cum per 10 sqm and at an approximate spacing of 10 cm center to center in Sqm 245.00
both directions, pressed into surface when the temperature of surfaces not less than 100 deg.
C, protruding 1 mm to 4 mm over mastic surface, all complete as per clause 5100.5 complete
as per specifications. MORTH Specification No. 515 & 2702

32.2 KSRRB M2700- Railing KSRRB M2700-2. Construction of precast RCC railing of M-30
Grade, aggregate size not exceeding 12 mm, true to line and grade, tolerance of vertical RCC
post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed
2000 mm, leaving adequate space between vertical post for expansion, complete as per m 1614.00
approved drawings and technical specifications complete as per specifications MORTH
Specification No. 2703,1500,1600 & 1700

32.3 KSRRB M2700-3. Construction of RCC railing of M30 Grade in-situ with 20 mm nominal
size aggregate, true to line and grade, tolerance of vertical RCC post not to exceed 1 in 500,
centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate
space between vertical post for expansion, complete as per approved drawings and technical m 1570.00
specifications complete as per specifications MORTH Specification No. 2703,1500,1600 &
1700

32.4 KSRRB M2700-4. Providing, fitting and fixing mild steel railing complete as per drawing
and Technical Specification complete as per specifications MORTH Specification No. m 2907.00
2703.2, 1900
32.5 KSRRB M2700-5. Drainage Spouts complete as per drawing and Technical specification
No 1645.00
complete as per specifications MORTH Specification No. 2705
32.6 KSRRB M2700- Approach Slab KSRRB M2700-6. PCC M15 Grade leveling course below
approach slab complete as per drawing and Technical specification complete as per cum 5441.00
specifications MORTH Specification No. 2700
32.7 KSRRB M2700-7. Reinforced cement concrete M30 approach slab including reinforcement
at 50kgs / cum and formwork complete as per drawing and Technical specification complete
as per specifications MORTH Specification No.1500, 1600, 1700 & 2704 cum 8844.00

32.8 KSRRB M2300 - 16 Provinding and laying cement concrete wearing coat with OPC cement
design mix M30@360 kgs, with 20mm and down size graded granite metal coarse
aggregates @ 0.69 cum and fine aggregates @ 0.46 cum, and reinforcement at 75 kgs / cum
with superplastisiser@ 3lts confirming to IS9103-1999 Reaffirmed- 2008 including cost of cum 10278.00
reinforcemnet complete as per drawing and Technical Specifications complete as per
specifications MORTH Specfications No. 2702

Page No. 246

Page 191 of 350


32.9 KSRRB M2700- Precast Pretensioned Girders KSRRB M2700-9. Providing, precasting,
transportation and placing in position precast pretensioned concrete girders as per drawing
and technical specifications including the cost high tensiled strands complete as per cum 22434.00
specifications MORTH Specification No.1800 & 2300
32.10 KSRRB M2700-10. Providing and fixing Helical pipes in voided concrete slabs complete as
m 371.00
per specifications MORTH Specification No. 1700 & 1800
32.11 KSRRB M2700- Painting on Concrete Surface KSRRB M2700-12. Providing and applying
2 coats of water based cement paint to unplastered concrete surface after cleaning the surface
of dirt, dust, oil, grease, efflorescence and applying paint at of 1 litre for 2 sqm complete as Sqm 63.00
per specifications MORTH Specification No. 800
32.13 Providing and laying 3mm thick asphalt seal pad made of actatic polypropylene polymer
(app) modified bituminous pad reinforced with non woven polyester mat of high bear
Sqm 442.00
strength as a carrier (confirming to ASTM - D6222 (S) Specification) on concrete bridge
deck slab complete as per specifications.
Page No. 247

33.0 33.BRIDGES - REPAIR AND REHABILITATION

33.1 KSRRB M2800-1. Removal of existing cement concrete wearing coat including its disposal
complete as per Technical Specification without causing any detrimental effect to any part of
the bridge structure and removal of dismantled material with all lifts and lead complete as Sqm 86.00
per specifications MORTH Specification No.2809
33.2 KSRRB M2800-2. Removal of existing asphaltic wearing coat comprising of 50 mm thick
asphaltic concert laid over 12 mm thick mastic asphalt including disposal with all lift and Sqm 61.00
lead complete as per specifications MORTH Specification No. 2809
33.3 KSRRB M2800-3. Guniting concrete surface with cement mortar applied with compressor
after cleaning surface and spraying with epoxy complete as per Technical Specification. Sqm 625.00
MORTH Specification No.2807
33.4 KSRRB M2800-4. Providing and inserting nipples with approved fixing compound after
drilling holes for grouting as per Technical Specifications including subsequent
cutting/removal and sealing of the hole as necessary of nipples after completion of grouting No 93.00
with Cement / Epoxy complete as per specifications MORTH Specification No. 2800

33.5 “KSRRB M2800-5.1. Sealing of cracks / porous concrete by injection process through
nipples/Grouting complete as per Technical Specification A. Cement Grout” MORTH Kgs 211.00
Specification No. 2806
33.6 “KSRRB M2800-5.2. Sealing of cracks / porous concrete by injection process through
nipples/Grouting complete as per Technical Specification . B. Cement Mortar (1:1) Kgs 206.00
Grouting” MORTH Specification No. 2806
33.7 KSRRB M2800-6. Patching of damaged concrete surface with polymer concrete and curing
compounds, initiator and promoter, available in present formulations, to be applied as per
instructions of manufacturer and as approved by the Engineer complete as per specifications Sqm 670.00
MORTH Specification No. 2800
33.8 KSRRB M2800-7. Sealing of crack / porous concrete with Epoxy Grout by injection through
nipples complete as per clause 2800.3.1 complete as per specifications MORTH Kgs 376.00
Specification No. 2803
33.9 KSRRB M2800-8. Applying epoxy mortar over leached, honey combed and spalled concrete
surface and exposed steel reinforcement complete as per Technical Specification. MORTH Sqm 483.00
Specification No. 2804
Page No. 249
33.10 KSRRB M2800-9. Removal of defective concrete, cleaning the surface thoroughly, applying
the shotcrete mixture mechanically with compressed air under pressure, comprising of
cement, sand, coarse aggregates, water and quick setting compound in the proportion as per
clause 2800.7.1. sand and coarse aggregates conforming to IS: 383 and table 1 of IS: 9012
respectively, water cement ratio ranging from 0.35 to 0.50, density of gunite not less than Sqm 295.00
2000 kg/cum, strength not less than 25 Mpa and workmanship conforming to clause
2800.7.6 complete as per specifications MORTH Specification No. 2807

Page 192 of 350


33.11 KSRRB M2800-10. Applying pre-packed cement based polymer mortar of strength 45 Mpa
at 28 days for replacement of spalled concrete complete as per specifications MORTH Sqm 431.00
Specification No. 2800
33.12 KSRRBM 2800-11. Eproxy bonding of new concrete to old concrete complete as per
Sqm 651.00
specifications MORTH Specification No. 2805
33.13 KSRRB M2800-12.1. Providing external prestressing with high tensile steel wires / strands
for taking output of 1 MT, including drilling for passage of prestessing steel, all accessories
for stressing and stressing operation and grouting complete as per drawing and Technical Tonne 419796.00
Specification MORTH Specification No. 2810
33.14 KSRRB M2800-12.2. Providing external prestressing with high tensile steel wires /strands
for taking output of 3.10 MT, including drilling for passage of prestessing steel, all
accessories for stressing and stressing operation and grouting complete as per drawing and Tonne 305569.00
Technical Specification MORTH Specification No. 2810
33.15 KSRRB M2800-12.3. Providing external prestressing with high tensile steel wires / strands
for taking output of 9.28 MT, including drilling for passage of prestessing steel, all
accessories for stressing and stressing operation and grouting complete as per drawing and Tonne 272855.00
Technical Specification MORTH Specification No. 2810
33.16 KSRRB M2800-13. Replacement of Bearings complete as per Technical Specification
complete as per specifications MORTH Specification No. 2810
33.16.1 KSRRB M2800-13. Replacement of Bearings complete as per Technical Specification
complete as per specifications MORTH Specification No. 2810 - Bearing Rocker & Roller Nos 14094.00

33.16.2 KSRRB M2800-13. Replacement of Bearings complete as per Technical Specification


No 11090.00
complete as per specifications MORTH Specification No. 2810 - Bearing Neoprene
33.18 KSRRB M2800-15. Replacement of Expansion Joints complete as per drawings complete as
m 3451.00
per specifications
33.19 KSRRB M2800-16. Replacement of Damaged Concrete Railing complete as per
m 200.00
specifications
33.20 KSRRB M2800-17. Replacement of Crash Barrier complete as per specifications m 376.00
33.21 KSRRB M2800-18. Replacement of Damaged Mild Steel Railing complete as per
m 165.00
specifications
Page No. 250
33.22 KSRRB M2800-19. Repair of Crash Barrier. Repair of concrete crash barrier with cement
concert of M-30 grade by cutting and trimming the damaged portion to a regular shape,
cleaning the area to be repaired thoroughly, applying cement concert after erection of proper m 343.00
form work complete as per specifications
33.23 KSRRB M2800-20. Repair of RCC Railing Carrying out repair of RCC M-30 railing to
m 182.00
bring it to the original shape complete as per specifications
33.24 KSRRB M2800-21. Repair of Steel Railing to bring it to the original shape complete as per
m 252.00
specifications
Page No. 251

34.0 34.PIPE CULVERTS

34.1 KSRRB M2900- PCC 1:3:6 in Foundation KSRRB M2900-1. Plain cement concrete 1:3:6
mix with crushed stone aggregate 40 m nominal size mechanically mixed, placed in
foundation and compacted by vibration including curing complete as per specifications cum 4434.00
MORTH Specification No. 408
34.2 KSRRB M2900-2.1. Laying Reinforced cement concrete pipe NP4 / prestressed concrete
pipe for culverts on first class bedding of granular material in single row including fixing
collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, m 10256.00
concrete and masonry works in head walls and parapets complete as per specifications.
MORTH Specification No. 2900 A. 1000 mm dia

34.3 KSRRB M2900-2.2. KSRRB M2900-2.1. Laying Reinforced cement concrete pipe NP4 /
prestressed concrete pipe for culverts on first class bedding of granular material in single row
including fixing collar with cement mortar 1:2 but excluding excavation, protection works,
backfilling, concrete and masonry works in head walls and parapets complete as per m 11247.00
specifications. MORTH Specification No. 2900 B. 1200 mm dia MORTH Specification No.
2900

Page 193 of 350


34.4 KSRRB M2900-3.1. Laying Reinforced cement concrete pipe NP4 / prestressed concrete
pipe for culverts on first class bedding of granular material in double row including fixing
collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, m 20570.00
concrete and masonry works in head walls and parapets complete as per specifications.
MORTH Specification No. 2900 A. 1000 mm dia
34.5 KSRRB M2900-3.2. KSRRB M2900-3.1. Laying Reinforced cement concrete pipe NP4 /
prestressed concrete pipe for culverts on first class bedding of granular material in double
row including fixing collar with cement mortar 1:2 but excluding excavation, protection
works, backfilling, concrete and masonry works in head walls and parapets complete as per m 22555.00
specifications. MORTH Specification No. 2900 B. 1200 mm dia MORTH Specification No.
2900

34.6 Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300
34.6.1 Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 1583.00
No.1000 / 2300 - - 300mm. dia
34.6.2 Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 2767.00
No.1000 / 2300 - - 450mm. dia
34.6.3 Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 3448.00
No.1000 / 2300 - - 600mm. dia
34.6.4 Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 3762.00
No.1000 / 2300 - - 750mm. dia
34.6.5 Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 6025.00
No.1000 / 2300 - - 900mm. dia
34.6.6 Providing and laying reinforced cement concrete pipe NP3 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 9292.00
No.1000 / 2300 - - 1200mm. dia
34.7 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification
No.1000 / 2300
34.7.1 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 411.00
No.1000 / 2300 - -150mm dia
34.7.2 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 552.00
No.1000 / 2300 - - 250mm dia
34.7.3 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 1108.00
No.1000 / 2300 - - 300mm dia
Page No. 253

Page 194 of 350


34.7.4 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 1509.00
No.1000 / 2300 - - 450mm dia
34.7.5 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 2289.00
No.1000 / 2300 - - 600mm dia
34.7.6 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 2830.00
No.1000 / 2300 - - 750mm dia
34.7.7 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 3634.00
No.1000 / 2300 - - 900mm dia
34.7.8 Providing and laying reinforced cement concrete pipe NP2 for culverts including pointing
ends, and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing
complete as per specifications. Specifications. No. KSRB 1000, 2300 MOST Specification m 6144.00
No.1000 / 2300 - - 1200mm dia
34.8.1 Providing and constructing granite / trap / basalt size stone masonry in
foundation with cement mortar 1:8 stone hammerd dressed in courses not
less than 20 cms high, bond stones at two m. apart in each course including cum 4037.00
cost of materials, labour, curing complete as per specifications. KBS 5.1.13
34.8.2 Providing and constructing granite / trap / basalt size stone masonry in
foundation with cement mortar 1:6 stone hammerd dressed in courses not
less than 20 cms high, bond stones at two m. apart in each course including cum 4187.00
cost of materials, labour, curing complete as per specifications. KBS 5.1.13
34.09 Providing and constructing granite / trap / basalt size stone masonry
in basement with cement mortar 1:6, edges of stones chistle dressed
in courses not less than 15 cms high, bond stones at two m. apart in cum 5005.00
each course including cost of materials, labour, curing complete as per
specifications.
34.10.1 Providing and constructing granite / trap / basalt size stone masonry in
superstructure with cement mortar & edges of stones chistle dressed in
courses not less than 15 cms high, bond stones at two m. apart in each
course including cost of materials, labour, scaffolding, curing complete as cum 5249.00
per specifications. KBS 5.1.13
- do - with cement mortar 1:6

34.10.2 Providing and constructing granite / trap / basalt size stone masonry in
superstructure with cement mortar & edges of stones chistle dressed in
courses not less than 15 cms high, bond stones at two m. apart in each
course including cost of materials, labour, scaffolding, curing complete as cum 5393.00
per specifications. KBS 5.1.13
- do - with cement mortar 1:4

34.11 Providing and laying in position plain cement concrete of mix 1:2:4 with
cement @ 240kgs, with 20mm and down size graded granite metal coarse
aggregates @ 0.69 cum and fine aggregtes @ 0.459cum, machine mixed,
concrete laid in layers not exceeding 15 cms. thick, well compacted, for cum 5293.00
coping. Including cost of all materials, labour, HOM of machinery, curing
complete as per specifications.
Specification No. KBS 4.1, 4.2. (P. No. 247/ I. No.34.11 of CSR 2015-16)

34.12.1 Providing flush pointing to square rubble, course or uncoursed stone


masonry with cement mortar, 20mm deep, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing complete as
per specifications. sqm 97.00
– do – cement mortar 1:4

Page 195 of 350


34.12.2 Providing flush pointing to square rubble, course or uncoursed stone
masonry with cement mortar, 20mm deep, after raking joints to depth of
20mm nicely lining, including cost of materials, labour, curing complete as sqm 95.00
per specifications.
– do – cement mortar 1:3
34.13.1 Providing ruled pointing to coursed stone masonry with cement mortar,
20mm deep, after raking joints to depth of 20mm nicely lining, including
cost of materials, labour, curing complete as per specifications. sqm 95.00
– do – cement mortar 1:4
34.13.2 Providing ruled pointing to coursed stone masonry with cement mortar,
20mm deep, after raking joints to depth of 20mm nicely lining, including
cost of materials, labour, curing complete as per specifications. sqm 98.00
– do – cement mortar 1:3
34.14 Providing and constucting pithcing / Revetment of 30 cm thick on slopes
using granite/basalt/trap/stones of surface area not less than 0.04 sqm and
wedged with spalls including cost of all materials, labour etc., complete as sqm 381.00
per specification.
Page No. 254

35.0 35.MAINTENANCE OF ROADS

35.1 KSRRB M3000- Restoration of Rain Cuts KSRRB M3000-1. Restoration of rain cuts with
soil, moorum, gravel or a mixture of these, clearing the loose soil, benching for 300 mm
width, laying fresh material in layers not exceeding 250 mm and compacting with plate m 89.00
compactor or power rammers to restore the original alignment, levels and slopes complete as
per specifications MORTH Specification No. 3002
35.2 KSRRB M3000- Maintenance of Earthen Shoulder KSRRB M3000-2. Making up loss of
material / irregularities on shoulder to a minimum depth of 150 mm to the design level by
adding fresh approved soil and compacting it with appropriate equipment complete as per Sqm 21.00
specifications MORTH Specification No.3003
35.3 KSRRB M3000-3. Stripping excess soil from the shoulder surface to a minimum depth of
150 mm to achieve the approved level and compacting with plate compactor complete as per Sqm 11.00
specifications MORTH Specification No. 3003
35.4 KSRRB 3000 Filling Pot-holes and Patch Repairs with Open-Graded Premix Surfacing, 20
mm KSRRB M3000-4. Removal of all failed material, trimming of completed excavation to
provide firm vertical faces, cleaning of surface, painting of tack coat on the sides and base of
excavation as per clause 500.3, back filling the pot holes with hot bituminous material as per Sqm 157.00
clause 500.11, compacting, trimming and finishing the surface to form a smooth continuous
surface, all as per clause 3004.2 complete as per specifications MORTH Specification No.
3004.2

35.5 KSRRB 3000 Filling Pot-holes and Patch Repairs with Bituminous Concrete, 40 mm
KSRRB M3000-5. Removal of all failed material, trimming of completed excavation to
provide firm vertical faces, cleaning of surface, painting of tack coat on the sides and base of
excavation as per clause 500.3, filling back the pot holes with hot bituminous material as Sqm 285.00
per clause 500.4, compacting, trimming and finishing the surface to form a smooth
continuous surface, all as per clause 3004.2 complete as per specifications MORTH
Specification No. 3004.2

35.6 KSRRB M3000- Crack Filling KSRRB M3000-6. Filling of crack using slow - curing
bitumen emulsion and applying crusher dust in case crack are wider than 3mm complete as m 3.00
per specifications MORTH Specification No. 3004.3.3
35.7 KSRRB M3000- Dusting KSRRB M3000-7. Applying crusher dust to areas of road where
bleeding of excess bitumen has occurred complete as per specifications MORTH m 2.00
Specification No. 3004.4
35.8 KSRRB 3000 Repair of Joint Grooves with Epoxy Mortar KSRRB M3000-8. Repair of
spalled joint grooves of contraction joints, longitudinal joints and expansion joints in
concrete pavements using epoxy mortar or epoxy concrete complete as per specifications. m 344.00
MORTH Specification No. 3005.1
Page No. 257

Page 196 of 350


35.9 KSRRB M3000- Repair of Old Joint Sealant KSRRB M3000-9. Removal of existing sealant
and re sealing of contraction, longitudinal or expansion joints in concrete pavement with
fresh sealant material complete as per specifications MORTH Specification No. 3005.2 m 33.00

35.10 KSRRB M3000- Hill Side Drain Clearance KSRRB M3000-10. Removal of earth from the
choked hill side drain and disposing it on the valley side manually complete as per m 34.00
specifications MORTH Specification No. 3000
35.11 KSRRB M3000- Landslide Clearance in Soil KSRRBM 3000-11. Clearance of land slides in
soil and ordinary rock by a bull-dozer D 80 A-12, 180 HP and disposal of the same on the
valley side complete as per specifications MORTH Specification No. 3000 cum 11.00

35.12 KSRRB M3000- Landslide Clearance in Hard Rock Requiring Blasting KSRRB M3000-12.
Clearing of land slide in hard rock requiring blasting for 50% of the boulders and disposal of
the same on the valley side complete as per specifications MORTH Specification No. 3000 cum 56.00

35.13
Patching of deep potholes by restoring the granular base course using material confirming to
WBM garde -III standards /WMM wherver necessary by manual means including trimming
the pothole to the required shape and size, cleaning the pothole applying tack coat at 4
kg/10sqm over the WBM/WMM surface including cleaning etc, and covering the surface
with premixed mix seal TYPE-A 20mm thick including lead, loading unloading, rolling and
finishing etc., Complete as per standard specification.

35.13.1
Patching of deep potholes by restoring the granular base coarse using material confirming to
WBM garde -III standards /WMM wherver necessary by manual means including trimming
the pothole to the required shape and size, cleaning the pothole applying tack coat at 4
Sqm 333.00
kg/10sqm over the WBM/WMM surface including cleaning etc, and covering the surface
with premixed mix seal TYPE-A 20mm thick including lead, loading unloading, rolling and
finishing etc., Complete as per standard specification. - - upto 75 mm thick

35.13.2
Patching of deep potholes by restoring the granular base coarse using material confirming to
WBM garde -III standards /WMM wherver necessary by manual means including trimming
the pothole to the required shape and size, cleaning the pothole applying tack coat at 4
sqm 407.00
kg/10sqm over the WBM/WMM surface including cleaning etc, and covering the surface
with premixed mix seal TYPE-A 20mm thick including lead, loading unloading, rolling and
finishing etc., Complete as per standard specification. - - upto 150mm thick

35.14 patching of shallow potholes on asphalt surfaces by using corresponding standard premixes
including removing the failed materials on the road surface, preparation of potholes to the
required standards before patching them, application of tack coat at 2.5 kg/10 sqm over the
asphalt surface including lead, loading unloading, rolling and finishing etc., complete as per
standard specification.
35.14.1 patching of shallow potholes on asphalt surfaces by using corresponding standard premixes
including removing the failed materials on the road surface, preparation of potholes to the
required standards before patching them, application of tack coat at 2.5 kg/10 sqm over the
asphalt surface including lead, loading unloading, rolling and finishing etc., complete as per Sqm 152.00
standard specification. - - using MSS Type - A upto 20 mm thick

35.14.2 patching of shallow potholes on asphalt surfaces by using corresponding standard premixes
including removing the failed materials on the road surface, preparation of potholes to the
required standards before patching them, application of tack coat at 2.5 kg/10 sqm over the
asphalt surface including lead, loading unloading, rolling and finishing etc., complete as per Sqm 154.00
standard - - using SDBC 25 mm thick.

35.14.3 patching of shallow potholes on asphalt surfaces by using corresponding standard premixes
including removing the failed materials on the road surface, preparation of potholes to the
required standards before patching them, application of tack coat at 2.5 kg/10 sqm over the
asphalt surface including lead, loading unloading, rolling and finishing etc., complete as per Sqm 303.00
standard specification. - - using BM for base coarse 50mm thick and 25mm thick SDBC
for finishing

Page 197 of 350


Page No. 258

36.0 36.REINFORCED EARTH STRUCTURE

36.1 KSRRB M3100-2. Assembling, joining and laying of reinforcing elements. A. With
reinforcing element of steel / aluminium strips / polymeric strips MORTH Specification No. m 262.00
3102
36.2 KSRRB M3100-3. Assembling, joining and laying of reinforcing elements B. With
Sqm 385.00
reinforcing element of synthetic geogrids MORTH Specification No. 3102
36.3 KSRRB M3100-4. Facing Elements of RCC MORTH Specification No. 3104 Sqm 1572.00
Page No. 260

37.0 37.OTHER ITEMS

37.1 Providing erecting and removing casurinapole Barricading using poles of 7.50 to 10 cms.
Dia and 1.5 height above ground fixed vertically at intervals of 2.0 to 2.5 mtrs. C/C and
Horizontally at 0.50 mtrs, above ground level, including fixing poles in the ground level for
minimum depth of 0.30 mtr and tied with coir rope firmly including cost and conveyance of
all materials, labour, lead and lift charges and complete.

37.1.1 Providing erecting and removing casurinapole Barricading using poles of 7.50 to 10 cms.
Dia and 1.5 height above ground fixed vertically at intervals of 2.0 to 2.5 mtrs. C/C and
Horizontally at 0.50 mtrs, above ground level, including fixing poles in the ground level for
minimum depth of 0.30 mtr and tied with coir rope firmly including cost and conveyance of m 55.00
all materials, labour, lead and lift charges and complete. - - For two tier Barricading

37.1.2 Providing erecting and removing casurinapole Barricading using poles of 7.50 to 10 cms.
Dia and 1.5 height above ground fixed vertically at intervals of 2.0 to 2.5 mtrs. C/C and
Horizontally at 0.50 mtrs, above ground level, including fixing poles in the ground level for
minimum depth of 0.30 mtr and tied with coir rope firmly including cost and conveyance of m 71.00
all materials, labour, lead and lift charges and complete. - - For three tier Barricading

37.2 Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of 65x65x6 mm
welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm dia M.S. hold fast rods each of
length 25 cms. Including cost of all materials cutting, bending scaffolding wherever
necessary, nicely finishing the welded joints with all lead lifts and as per the directions of the m 819.00
Engineerin - charge of the work and including providing 2 coats of approved quality paint
over one coat of shop painting ( excluding cost of earthwork and concrete)

37.3 Providing chain link fencing 50mm size of 8 guage properly stretched between existing
rectangular poles and fixed with suitable bolts & nuts, the free ends shall be welded to the
pole and block pipe at top and bottom as required including cost of all materials, labour, lead Sqm 659.00
and lifts and as per the directions of the Engineer-in-charge of work including two coats of
approved quality paint over one coat of shop paint
37.4 Providing and fixing M.S. Block pipe of 38mm dia, of heavy guage of 14 including
removing the bends, cutting the pipe, and fixing pipe in between the existing two verticle
poles (M.S. rectangular poles) and spot welding the chain link with M.S. block pipe
including cost of all materials wastage in cutting, and scaffolding wherever necessary with m 324.00
all lead and lift as directed by the Engineer-in-charge of work etc., complete including two
coats of approved quality paint over one coat of shop paint.

37.5 Providing barbed GI wire fencing of 12x12 gauge drawn into stone pillars or iron pillars
including drawing in holes wherever necessary excluding the cost of pillars but including the m 28.00
cost of barbed wire and binding wire etc., complete.
37.6 Providing corrugated cement asbestos Ridge sheets set in C.M. 1:3 and pointed with C.M.
m 436.00
1:3.
37.7 Providing Mangalore Ridge tiles set in C.M. 1:2 and pointed with C.M. 1:2. (P.No.255,
m 176.00
I.No.37.7 of PWD SR 2015-16)

Page 198 of 350


37.8 Fixing doors, window and ventilators in walls. No 204.00
37.9 Supplying and fixing new Mangalore tiles on existing reepers. (P.No.256, I.No.37.15 of
Sqm 363.00
PWD SR 2015-16)
37.10 Removing and fixing old Mangalore ridge tiles including pointing with C.M. 1:3. m 63.00

Page No. 262

37.11 Repairs to roof with available corrugated zinc sheets/ A.C.sheets with new J bolts, screws
Sqm 63.00
and washers etc., on existing reeper and rafters.
37.12 Repairing door and window frames with available wood to the required size. (P.No.256,
Sqm 420.00
I.No.37.12 of PWD SR 2015-16)
37.13 Repairing and fixing shutters (panelled or glazed) to doors, windows, ventilators and
Sqm 420.00
cupboards.
37.14 Fixing old eve board with necessary screws and approved painting two coats. m 16.00
37.15 Providing and fixing plain rolled glass 3mm thick with T.W beading of 10mm thick.
Sqm 706.00
(P.No.256, I.No.37.15 of PWD SR 2015-16)
37.16 Providing and fixing 4mm thick glass panes to steel windows including T.W. beading of 10
Sqm 920.00
mm thick and 2 coats of approved paints.
37.17 Easing of shutters of door. (P.No.256, I.No.37.17 of PWD SR 2015-16) No 53.00
37.18 Easing of window shutters. (P.No.256, I.No.37.18 of PWD SR 2015-16) No 52.00
37.19 Providing and fixing M.S bars to windows and ventilators including cutting making holes in
Kgs 100.00
frame work with two coats of approved paints.
37.20 Labour charges for fixing iron bars to windows including cutting fixing and making holes in
the frame work and painting two coats with approved paint etc., complete (excluding the Kgs 52.00
cost of iron bars)
37.21 Repairs to cornice or coping or mortar band, 15 cm deep and 8cm projection for damaged
Sqm 63.00
portion.
37.22 Removing cuddappa slab flooring and stacking the material with a lead of 50 meters. Sqm 31.00
37.23 Removing and resetting Mangalore tiles and replacing broken ones wherever necessary
Sqm 16.00
(excluding cost of new tiles).
37.24 Cleaning glass with chemicals. (P.No.256, I.No.37.24 of CSR 2015-16) Sqm 9.00
37.25 Removing and refixing existing mortar and pestle stone. Each 166.00
37.26 Removing by chiselling cement joints 50mm to 80mm deep in pipes upto 150mm dia. Sqm 31.00
37.27 Labour charges for fixing plain, frosted or pin headed glass panels (clear glass area) with
Sqm 277.00
teak wood beading.
37.28 Drilling holes of 2.50 cms dia (roof/chajja/stone).
37.28.1 Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 7.50 cms thick No 79.00
37.28.2 Drilling holes of 2.50 cms dia (roof/chajja/stone). - - in slabs upto 10 cms thick No 95.00
37.29 Providing and fixing mortar and pestle stone with suitable size of pestle stone including
three line dressing for top and two line dressing for the exposed faces
Page No. 263
37.29.1 Providing and fixing mortar and pestle stone with suitable size of pestle stone including
three line dressing for top and two line dressing for the exposed faces - - 50 cms x 50 cms x Set 318.00
60 cms
37.29.2 Providing and fixing mortar and pestle stone with suitable size of pestle stone including
three line dressing for top and two line dressing for the exposed faces - - 40 cms x 40 cms x Set 254.00
40 cms
37.30 Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc.,
Sqm 919.00
complete.
37.31 Providing and fixing mortise locks heavy duty to doors. Each 599.00
37.32 Providing and fixing hydraulic door closures-with mounting heavy duty. No 1644.00
37.33 Providing and fixing hydraulic door closures-Aluminium body. No 1136.00
37.34 Cleaning of glazed tiles. (P.No. 257, I.No. 37.34 of PWD SR 2015-16) Sqm 50.00
37.35 Wall bores in Brick masonry upto 45 cm thick. Each 78.00
37.36 Wall bores in size stone masonry
37.36.1 Wall bores in size stone masonry - - upto 45 cm thick. Each 187.00
37.36.2 Wall bores in size stone masonry - - upto 60 to 90cm thick. (P.No. 257/ I.No.37.36.2 of
Each 203.00
CSR 2015-16)
37.36.3 Wall bores in size stone masonry - - upto 90 to 120 cm thick. Each 234.00

Page 199 of 350


37.37 Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed
cum 227.00
including barricading, danger lighting etc., in the Macadam road.
37.38 Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed
including barricading, danger lighting etc., in the Asphalt surface road. (P.No.257/I.No. cum 340.00
37.38 of CSR 2015-16)
37.40 Cutting of road surface for pipeline trenches and disposing of the excavated stuff as directed
cum 607.00
including barricading, danger lighting etc., in the Cement concrete road.
37.41 Diversion of water course by providing Coffer dams or bunds or islands as may be necessary
for piers and abutments foundations, bailing out or pumping water during excavation and
until completion etc., complete.
37.41.1 Diversion of water course by providing Coffer dams or bunds or islands as may be necessary
for piers and abutments foundations, bailing out or pumping water during excavation and cum 268.00
until completion etc., complete. - - 1.50 mtrs depth below LWL.
37.41.2 Diversion of water course by providing Coffer dams or bunds or islands as may be necessary
for piers and abutments foundations, bailing out or pumping water during excavation and
until completion etc., complete. - - beyond 1.50 mtrs depth upto & including 3m depth. cum 330.00

37.41.3 Diversion of water course by providing Coffer dams or bunds or islands as may be necessary
for piers and abutments foundations, bailing out or pumping water during excavation and
until completion etc., complete. - - beyond 3.00 mtrs depth upto & including 4.5m depth. cum 495.00

37.41.4 Diversion of water course by providing Coffer dams or bunds or islands as may be necessary
for piers and abutments foundations, bailing out or pumping water during excavation and
until completion etc., complete. - - beyond 4.50 mtrs depth upto & including 6.00m depth. cum 595.00

37.42 Dismantling Mangalore tiles roof and stacking the material within a radius of 50 meters.

37.42.1 Dismantling Mangalore tiles roof and stacking the material within a radius of 50 meters. - -
Sqm 47.00
with reepers. (P.No. 257, I.No. 37.42.1 of SR 2015-16).
37.42.2 Dismantling Mangalore tiles roof and stacking the material within a radius of 50 meters. - -
Sqm 31.00
without reepers. (P.No. 257, I.No. 37.42.2 of SR 2015-16).
37.42.3 Dismantling Mangalore tiles roof and stacking the material within a radius of 50 meters. - -
Sqm 62.00
A.C. sheet roofing.
37.43 Dismantling CI or AC rain water Pipes with fittings and clamps and stacking the materials
Sqm 16.00
with a lead of 50 meters.
(Page No. 264
37.44 Dismantling weather proof course and removing and conveying the debris to a distance upto
cum 468.00
200m. (P.No. 258, I.No. 37.44 of CSR 2015-16).
37.45 Dismantling Madras terrace jack arch roof including rafters and stacking the materials with a
Sqm 156.00
lead upto 50m and removing the debris to a distance upto 200m.
37.46 Dismantling stone slab roofing over wooden reepers or RCC battens (dismantling reepers
and battens to be paid for separately) including stacking of serviceable materials and
disposal of unserviceable within 200m lead (with in average thickness of 10 cms Sqm 156.00

37.47 Dismantling burnt brick masonry in clay mortar/lime mortar/cement mortar and stacking the
bricks within a radius of 50m and removing the debris to a distance upto 200m. (P.No. 258, Sqm 156.00
I.No. 37.47 of SR 2015-16).
37.48 Dismantling size stone masonry in clay mortar and stacking the size stone within a radius of
cum 172.00
50m and removing the debris to a distance upto 200m.
37.49 Dismantling the tile work in floor and roof laid in cement or surki mortar including stacking
the materials with in 50 m lead of tiles thickness 10mm to 25mm. (P.No. 258, I.No. 37.49 of Sqm 31.00
SR 2015-16).
37.50 Dismantling plastering and removing the debris with a lead upto 200m. (P.No.258, I.No.
Sqm 23.00
37.50 of PWD SR 2015-16)
37.51 Dismantling cement concrete flooring or plain cement concrete work including removing
and conveying the debris to distance upto 200m (within average thickness of 15 cms). Sqm 55.00

37.52 Dismantling barbed wire or flexible wirer rope in fencing including making rolls and
m 5.00
stacking within 50m lead.

Page 200 of 350


37.53 Dismantling expanded metal or IRC fabric with weld mesh necessary battens and beading
Sqm 16.00
etc., including stacking the serviceable materials within 50 m lead.
37.54 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge with Mathi or
Nandi wood patties of 50 mm x 12 mm size, including two coats approved paint etc., Sqm 1151.00
complete. (Including cost of screws).
37.55 Providing and fixing 12.5mm to 25 mm expanded metal work of 14 gauge with Mathi or
Nandi wood patties of 50 mm x 12 mm size, including two coats approved paint etc., Sqm 1091.00
complete. (Including cost of screws). with weld mesh 75 mm X 25 mm 6G X 10G.
37.56 Removing and resetting of footpath slab Sqm 125.00
37.57 Removing and resetting of kerb stones m 62.00
37.58 Supplying water storage tanks made of virgin polymer (LLDPE) with two layers outer Black
or Blue and inner White layer of approved quality and make, conforming to I.S.I./ISO/SSI L 6.00
specifications. (P.No. 258/ I.No. 37.58 of CSR 2015-16)
37.59.1 Providing laying palin / reinforced cement concrete for Box Drain walls of thicknes 10cm to
20 cm including cenmtering shuttering form work etc. complete as per approved drawiong
and design MORTH Specification No. 1500,1700,2200 PCC M 15 Grade upto 0.75 m height cum 7138.00
using concrete mixture
37.59.2 Providing laying palin / reinforced cement concrete for Box Drain walls of thicknes 10cm to
20 cm including cenmtering shuttering form work etc. complete as per approved drawiong
and design MORTH Specification No. 1500,1700,2200 PCC M 20 Grade upto 0.75 m height cum 10408.00
using concrete mixture

Page No. 265


37.60 Providing and fixing RCC name board of size 1.35xk0.60x0.04 mtrs fixed in reinforced
cement concrete poles of size 0.10x0.10x2.60mtrs in cement concrete M 20 proportion using
20mm and down size graded metal machine mixed with 10mm dia main steel bars and 8mm
dia stirpes as shown in drawing. The board shall be provided with 12mm thick cement
plaster in cement mortar 1:3 on both the sides. The poles shall be embedded in the ground
for a depth of 0.5 mtrs with cement concrete M 10 proportion. The board shall be fixed as
per the drawing and at the place indicated by the Engineering charge of the work. The cost Each 4950.00
includes excavation, cost of all materials, cost of steel, centering, transportation charges,
fixing charges etc., The work shall be carried out as per the detailed specifications, drawings
and directions of the Engineer in charge of the work.

37.61 Providing and fixing sign board of size 60x60cm equilateral triangle using M.S sheet 5mm
thick with RCC pole of size 0.15x0.15x2.3 mtr made out of cement concrete M 20
proportion using 20mm and down size graded metal machine mixed with 10mm dia main
steel bars and 8mm dia stirupps as shown in drawing. The poles shall be embedded in the
ground for a depth of 0.6mtrs with cement concrete M 10 proportion. The board shall be
fixed as per the drawing and at the place indicated by the Engineering charge of the work. Each 3450.00
The cost includes excavation, cost of all materials, cost of steel, centering, transportation
charges, fixing charges etc., The work shall be carried out as per the detailed specifications,
drawings and directions of the Engineer in charge of the work.

37.62 Providing and constructing informatory name board of size 1.75m x 1.75m with Burnt brick
masonry in CM 1:6 with non-modular bricks of standard size of class designation 50 (table
moulded). The foundation shall be provided with cement concrete M 7.5 for a depth of
10cms and with size stone masonry with Cement Mortar 1:6 and copping concrete with
cement concrete M 10 as indicated in the drawing. The name board shall be provided with
12mm thick plaster in CM 1:6 on both the sides including rounding of corners. The name
board shall be provided with painting with 2 coats of enamel paint. The board shall be fixed Each 6650.00
as per the drawing and at the place indicated by the Engineering charge of the work. The cost
includes excavation, cost of all materials, centering, transportation charges, fixing charges
etc., The work shall be carried out as per the detailed specifications, drawings and directions
of the Engineer in charge of the work.

37.63 Providing two bulb underreemed pile foundation upto maximum 5m depth including hire
charges of machineries digging the pile holes, labour charges and laying 20mm and down
size jelly RCC M 20 keeping the reinforcement edge cutting etc., complete as per
specifications.

Page 201 of 350


37.63.1 Providing two bulb underreemed pile foundation upto maximum 5m depth including hire
charges of machineries digging the pile holes, labour charges and laying 20mm and down
size jelly RCC M 20 keeping the reinforcement edge cutting etc., complete as per m 734.00
specifications. - - 23 cm dia
37.63.2 Providing two bulb underreemed pile foundation upto maximum 5m depth including hire
charges of machineries digging the pile holes, labour charges and laying 20mm and down
size jelly RCC M 20 keeping the reinforcement edge cutting etc., complete as per m 1238.00
specifications. - - 30 cm dia
37.64 Providing and fixing RCC precast fencing pole of size 0.15m x 0.15m x2.0m casted in CC
1:1.5:3 with 20mm downsize aggregate making holes for drawing barbed wire at 30cm c/c
using 10 mm dia vertical 4 TMT steel rods and 8mm dia stirrups at 15cm c/c fixed 1.5m
above ground level using steel moulding, curing, transportation to work spot including
excavation in hard soil fixing in plain cement concrete 1:2:4 using 20mm downsize Each 1529.00
aggregate including aligning to plumb and line providing including cost of all materials,
labour, hire charge of machineries lead, lift loading & unloading etc.,Complete.

Page No. 266

ADDITIONAL ITEMS FOR MANGALORE CIRCLE


37.65.1
37.65.2
37.65.3
37.65.4
37.66
37.66.1
37.66.2
37.66.3
37.66.4
37.66.5
37.66.6
37.67
37.68
37.69
37.70
37.71
37.72
37.73
37.74
37.75
Page No. 268

38.0 38. INNOVATIVE ITEMS

Page 202 of 350


38.1 WATER PROOFING TO CONCRETE SURFACES Using Membrane Technology For raft
& retaining wall Providing & applying water proofing to concrete surfaces using high
quality polymer-modified bituminous compounds (confirming to ASTM D
5147) reinforced with non woven polyester fabric, weighing 180gm/sqm granular finish
4mm thick by torch on application method confirming to the properties indicated below. It
shall be provided after priming the surface using bitumen primer at 0.2 ltr /sqm.
Detailed specification & Methodology
1. Membrane thickness 4mm (+ or – 5%)
2. Tensile strength – Longitudinal 790 N/5cm Transverse 730 N/5cm
3. Elongation of Membrane - Longitudinal 65% Transverse 69%
4. Tear Resistance - Longitudinal 180 N Transverse 190 N
5. Lap joint strength - Longitudinal 750 N/5cm Transverse 550 N/5cm Sqm 480.00
6. Puncture Resistance – Static 1.4 Dynamic 1.3
7. Water absorption - < 0.15%
8. Water permeability - Nil
9. Chemical resistance – Chloride, sulphate and Nitrate
The area to be water proofed shall be free from loose aggregate, dust free and in dry
condition. Primer must be applied to the surface and allowed to dry prior to application of
membrane. The membrane shall be applied within 6 hours after application of primer. The
membrane comes in a roll form shall be unrolled and placed in the correct position where it
has to be torched. Each layer must over lap the next layer by min 10cm at the adjacent and
15cm at the ends. The heat application through propane gas torch shall be applied on
membrane thus causing melting and subsequent adhesion in the surface. The membrane
38.2 For roof slab & terraces Providing & applying water proofing to roof slab, terraces,
landscape area, podium etc., using modified polyurethane cures (conforming to ASTM
C836-84) to give a tough elastomeric waterproof membrane on the surface. The surface
shall be cleaned free from dust and other particle before usage. standards &
methodology :
Sqm 700.00
This compound has a medium viscosity grade with 620% of elongation and shall be done
either by roller application/brush application/ spray. This will be applied for a thickness of
1.3mm first layer 0.5mm & 2nd layer 0.8mm. After applying the 2nd layer sand sprinkle
shall be done to provide mechanical key.

Page 203 of 350


38.3 ISOPROOF SEALER Providing waterproof treatment to roof slab using 2 coats of acrylic
co polymer elastomeric ISOPROOF sealer & protector. The surface shall be prepared free
of tar, dust, fungus, loose particles etc.,The surface shall be applied with basecoat of
crystallization liquid and then ISOPROOF, wetting agent and liquid (1:1:6) over the
prepared surface. In addition the surface shall be provided with polysulphide/ acrylic sealant
to V groves, making haunch at junction of parapet and roof slab and at damaged portion
using patching mortar to drain off rain water. Over this one coat of flexible cementatious
membrane (FCM), Spreading 2 layers of 40 gsm non woven geotextile membrane as
reinforcing material (over FCM) with one primer coat of ISOPROOF
& applying second coat of ISOPROOF liquid over the primer coat - conforming to ASTM D
412 - 1992. The work shall be carried out as per the directions of the Engineer in charge.
standards & methodology :
1. surface Preparation
The surface shall be made free from all dirt, fungus, loose particles by using wire brush. The
surface shall be cleaned with solvent like xylene, Toluene, Benzene, dilute hydro chloric
acid.
i) Cutting of ‘V’-Grooves : The V shaped grooves shall be cut along the location of all the
visible cracks. The ‘V’-Grooves shall be of size 5mm as directed by the Engineer in charge.
2. Primary reduction of water permeability Sqm 985.00
The concentrated crystallization liquid of specific gravity 1.09 is lightly diluted and applied
on the prepared surface. The sodium acetate formed during the chemical reaction penetrates
inside the pores of the concrete and reacts with water to form crystals to block the pores of
the concrete, there by reducing water permeability.
3. Porosity and voids reduction (base Coat application)
Applying wetting agent consisting of acrylic monomer, co-polymer liquid and crystallization
liquid as base on the prepared surface and V groove and cracks etc.
4. application of sealant / Patching mortar
Cracks will be sealed using suitable sealant or patching mortar. These make them ideally
suited for joint treatment. Its adhesion is very strong & binds with the building materials
such as concrete, and take care of expansion and contraction in the structures. 5.
levelling course using Flexible Cementatious material
A concrete mix in the ratio 1:1.5:3 (1:cement : 1.5 quartz powder :
3 graded stone) is laid to make haunch at junction of parapet and roof slab and at damaged
portions to drain off water.
The factory made dry CEMENTATIOUS silica sand power consisting of dry cement mortar
(1 cement : 4 silica sand) shall be mixed with additives like ISOPROOF chemical and
acrylic polymer and water to arrive at workable consistency. The same shall be applied over
Page No. 271
38.4 Atotic Polyproyelene Providing and laying Water proofing with single layer of 3mm thick
granule finish @ 4.5kg/sqm using Atotic Polypropylene membranes (APP) with overlap of
100mm at every joints including applying bitumen emulsion priming coat over the dry
surface, including scarifying the surface and removing dust and foreign materials removing Sqm 450.00
debris and cleaning surface with wire brush to give even surface. The work shall be carried
out as per the instructions of Engineer in charge of the work.

Page No. 276

Page 204 of 350


38.5 Admixture for concrete mix Concrete structures including water retaining structures
Providing admixture to concrete mix using INTEGRAL CRYSTALINE admixture. Integral
Crystalline Admixture shall be added @0.8% by weight of cement to the ready mix
concrete / concrete at the time of batching conforming to ASTM C 1202 & DIN V 18998.
methodology :
mixing: Admixture must be added to the concrete at the time of batching at 0.8% by weight
of cement. The sequence of procedures for addition will vary according to the type of batch
plant operation and equipment:
addition of admixture to rmC transit mixer / Concrete mixer: Mix Admixture with water to
form a very thin slurry 1 powder : 1.26 liters of water (e.g. 18 kg of powder mixed with 22.7
liters of water). Pour this material into the drum of the ready-mix truck/ concrete mixer. The Kgs 360.00
aggregate, cement and water should be batched and mixed in the plant in accordance with
standard practices (taking into account the quantity of water that has already been placed in
the ready-mix truck). Mix for at least 5 minutes to ensure even distribution of the Admixture
throughout the concrete.
addition of admixture to the batching Plant: Add Admix to the coarse aggregates and sand,
then mix thoroughly for 2 – 3 minutes before adding the cement and water. The total
concrete mass should be blended using standard practices. In case of a fully automated
Batching plant, the Admix shall be poured in the dry form (in the required pre- measured
quantity) to the coarse aggregates and sand while the same is being fed to the batching plant
through the conveyor belt.
Note: It is important to obtain a homogeneous mixture of Admixture with the concrete.
38.6 For Construction joints Providing pressure grouting for construction joints with cement
grout mixed with plasticised expanding grout admixtureat 225 grams/bag of cement
conforming to BS:8110 part 1 - 1985, Section 8,9,4.6. methodology:
The admixture, cement and water shall be added in the ratio of 225 gram/bag of cement /21 Point 95.00
ltrs of water. This shall be applied to concrete joints at a pressure of 2 to 4 kg/cm2 by using
pumping equipments. The admixture shall confirm to ASTM C827 and shall have
unrestrained expansion upto 4%

38.7 Water retaining Structures Providing & applying water proofing to concrete surfaces using
crystalline capillary water proofing system at 1 kg per sqm for concrete surfaces (confirming
to ASTM D 4060, D4541) followed by application of 2 coats of 1mm thick acrylic polymer
based cementatious coating. This crystalline water proofing compound in powder form shall
be mixed with water at
3:1 ratio (3 powder : 1 water) at the time of application. methodology:
The surface shall be pre damped with water. The water shall be mixed powder in the ratio of
3 powder :1water mixing thoroughly with a slow speed drill fitted at a speed RPM of
282640. The final crystalline slurry shall be applied with a soft brush bloom at average of 1 Sqm 470.00
kg /sqm area. Curing shall be minimum of 48 hour by treating the surface by fog spray
3 to 4 time a day. Acrylic / Liquid polymer compound shall be mixed with water by means
of using a slow speed drill mixer 500 RPM and gradually adding the powder component to
the liquid avoiding lump formation and mixed for 2 to 4 minutes. The slurry shall be applied
using stiff brush in 2 coats that forms 1mm thick. (0.5 mm thick each coat) Curing shall be
minimum of 48 hour by treating the surface by fog spray 3 to 4 time a day. Protection layer
such as plastering or concrete screen shall be applied on the water proof membrane surface.

Page No. 277


38.8 COVING Providing and laying 12mm thick coving at the junction of slab and vertical
offsets with CM 1:3 admixed with modified styrene butadiene rubber emulsion
(confirming to BS 6319) specially designed for use as a bonding aid and gauging liquid for
cementations system (5 ltrs for 50kg cement). methodology: r mt 145.00
Modified styrene butadiene rubber emulsion shall be added to dry mix of cement mortar of
1:3 (5 ltrs for 1 bag of cement and 3 bags of cement) mixed thoroughly by adding water 0.35
water cement ratio and peddling for 2 minutes.

Page 205 of 350


38.9 Swellable rapid expansion water proofing for construction joints in all types of concrete
works / composite works Providing and water proofing treatment to construction joints of
all types of concrete works using swellable rapid expansion in water. Water stop capable of
expanding 215% in 120 hours, when immersed potable water Conforming to ASTM D 297
& ASTM D 6 Standard methodology:
The water stopper shall be laid as per following steps:
i. Clean the surface sufficiently to receive the water stopper
ii. Apply a coat of primer to the area where water stopper is to be laid placed at an
application rate of 240 running meters per 3.78 Liters of primer (primer is supplied along
with water stopper)
iii. Using moderate hand pressure with the heel of the hand, press a continuous bead of
Water Stopper firmly into the position. Make sure that the product has bonded to the primed
area.
iv. Peel the protective backing form the exposed side of the water stop and tightly butt the
coil ends to form a continuous water stop. Do not overlap the water stop. m 500.00
v. Follow standard concrete pouring procedures here after.
The proposed water stopper shall be used for the following situations:
1. At all the cold construction joints
2. At the junction of Horizontal Raft and vertical retaining walls
3. At the Junction of horizontal Roof slab and vertical Parapet walls
4. At all cold construction joints in Water retaining structures such as water tanks, swimming
pools, water bodies on Podium, roof garden or Flower beds etc.
5. Around the Pipe penetrations, metal penetrations, any other
penetrations, where there is a joint between two different surfaces
– one of the surfaces being Concrete.
6. Construction joints in the lift Pits

Page No. 278


38.10 FOR CRACKS IN ROOFTOP SURFACES Providing Water proofer Capable of bridging
cracks upto 2mm in the Exposed Roof surface using Spray Applied Liquid Water proffer at
the rate of 0.20 ltr/sqm. Primer & chemical mortar shall be applied before applying this
spray liquid water proofer. The area shall be cleaned by high pressure water jet/wire bush or
by mechanical means to make it free from loose particle, dust dirt etc.
methodology :
1. The first part consisting of grouting the porous slab area with non-
shrink cementatious grout (if required).
2. The second part consisting of treating the cracks and construction joints by routing-out to
a minimum 20mm x 20mm groove and filling it with a crystalisation Mortar after priming
with crystalisation slurry.
3. The third part consisting of making vata at the interface joint of the slab and parapet with
crystalisation Mortar.
4. The fourth part consisting of sealing all joints of outlet drains pipe, etc. with crystalisation
Mortar.
5. The fifth part consisting of providing and applying liquid water proofer which can be
spray applied at a coverage of 0.2 lt/ sqmt “to permanently fix non-soluble crystalline growth
throughout the capillary tracts and pores of concrete. It is spray applied over the entire
terrace concrete slab and parapet walls up to 300 mm height

38.10.1 FOR CRACKS IN ROOFTOP SURFACES Providing Water proofer Capable of bridging
cracks upto 2mm in the Exposed Roof surface using Spray Applied Liquid Water proffer at
the rate of 0.20 ltr/sqm. Primer & chemical mortar shall be applied before applying this
spray liquid water proofer. The area shall be cleaned by high pressure water jet/wire bush or r mt 95.00
by mechanical means to make it free from loose particle, dust dirt etc. _ for crack filling

38.10.2 FOR CRACKS IN ROOFTOP SURFACES Providing Water proofer Capable of bridging
cracks upto 2mm in the Exposed Roof surface using Spray Applied Liquid Water proffer at
the rate of 0.20 ltr/sqm. Primer & chemical mortar shall be applied before applying this
spray liquid water proofer. The area shall be cleaned by high pressure water jet/wire bush or Sqm 350.00
by mechanical means to make it free from loose particle, dust dirt etc._ for applying spray

Page No. 279

Page 206 of 350


38.11 FOR TOILETS SUNK PORTIONS
Providing INTEGRAL CRYSTALINE Waterproofing treatment to the
sunken portion of Toilets. Using Crystalline Slurry of approved make @ 1.4kg per SQM in
two coats (0.7 kg per sqm per coat) conforming to ASTM C 1202 & DINV 18998 standards.
Methodology:
1. The first part consisting of grouting the porous slab area with
non-shrink cementatious grout (if required).
2. The second part consisting of treating the cracks and construction
joints by routing-out to a minimum 20mm x 20mm groove and treating
it with crystalisation Mortar. First it is primed with crystalisation
slurry and later filled with crystalisation mortar and later again a
coat of crystalisation slurry.
3. The third part consisting of making required slopes at the interface
Sqm 480.00
joint of the toilet slab and masonry wall with crystalisation Mortar..
4. The fourth part consisting of sealing / packing all joints of outlet
pipes, etc. with CRYSTALISATION MORTAR
5. The fifth part consisting of providing and applying In-depth Crystalline
Waterproofing System @ 1.4 kgs/sqm in 2 coats to permanently
fix non-soluble crystalline growth throughout the capillary
tracts and pores of concrete. The In-depth Crystalline waterproofing
Material shall be applied by brushing as per manufacturer’s
specification . on the entire toilet sunken slab and walls.

38.12 SELF CURING COMPOUND FOR CONCRETE SURFACE


(WATER/ WAX BASED)
Providing & applying water based (WB) / wax based low viscosity wax emulsion curing
compound membrane / layer applied in the form of spray over the concrete surface. The
material consists of self curing compound membrane satisfying ASTM C309-90 standard
ensuring a non penetrating continuous film on the concrete surface covering an area of 4.5 to L 110.00
5 sqm per ltr of curing compound and shall be applied with a distance of 45 cms after 5
hours of concreting to get the best results. This item shall be adopted wherever there is
scarcity of water and with prior approval of Superintending Engineer.

38.13 POLYMER BASED


Providing & applying high efficiency polymer based curing compound membrane / layer
applied in the form of spray over the roof surface. The material consists of self curing
compound membrane satisfying greater curing efficiency when tested to BS 7542 -1992
standard ensuring a non penetrating continuous film on the concrete surface, covering an
L 240.00
area of 3.5 to 5 sqm per liter of curing compound and shall be applied with a distance of 45
cms after 5 hours of concreting to get the best results. The above items shall be adopted
wherever there is scarcity of water and with prior approval of Superintending Engineer.

Page 207 of 350


38.14 PATCHING OF POTHOLES BY COLD MIX
Providing and laying bituminous cold mix of approved make (conforming to clause 519 of
MORT&H Specifications and requirements) for repair of roads in adverse climate condition
on the prepared surface, cleaning with broom as per specification, including laying in proper
camber and grade with regular size, compaction with hand rammer including cost of cold
mix, labour, lead, loading & unloading transportation, etc., complete, in all respect.
Main Features / Advantages of Bituminous cold Mix
• Ready for immediate use with pre-mixed aggregates (cold technology)
• No heating of mixing or additions to the product before or after
application
• Requires simple equipments such as hand brushes, shovel and a
rammer. The use of roller is not necessary
• No pretreatment of repair areas is required i.e, cutting out, use of
tack cost
• Instant curing/setting, partly by air-drying and partly by compaction
• All-weather usage product Instant repair of roads with bituminous
cold mix can be made in monsoons & wet conditions, extremes of
heat (60 C+) and cold conditions
• Eliminates necessity of plant & machinery at site Sqm 540.00
• Very fast setting as compared to other options
• After repairs, the road can be immediately opened to heavy traffic
reducing the traffic hold up time.
• No sticking/picking up of material by vehicle tyres
• Highly stable at high pavement temperatures
• Highly resistant to stripping by water
• Offers high skid resistance
• Leads to no raveling, no bleeding, no deparession/permanent deformation
• No wastage of material
• Minimum unskilled labour required
• Long service life of the repaired potholes
• No pollution during maintenance
How to use Bituminous Cold Mix
• Comes in convenient ready to use packing of 50 kg net HDPE
bags with inside LDPE liner
• Preparation prior to repair is minimal for optimum results, remove
standing water/loose debris/dust with a brush from the pothole.
• Pour Bituminous Cold Mix directly from the bag into the pothole
Page No. 280
38.15.1 RBI GRADE-81
Pulverising the local soil in place, spreading with rotavator duly adding the specified
quantity of inorganic Compound RBI Grade 81 as approved by CRRI, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader and
compacting with the road roller at OMC to the desired density for improving the
subgrade & shoulders. (The laboratory CBR of the compacted soil shall not be less
than 10)

38.15.1. RBI GRADE-81


1 Pulverising the local soil in place, spreading with rotavator duly adding the specified
quantity of inorganic Compound RBI Grade 81 as approved by CRRI, mixing thoroughly,
sprinkling desired quantity of water, grading with motor grader and compacting with the
road roller at OMC to the desired density for improving the subgrade & shoulders. (The cum 820.00
laboratory CBR of the compacted soil shall not be less than 10)
For soils having WL between 35 & 50, with 1% of inorganic Compound
like RBI Grade 81 by weight of Soil.

38.15.1. RBI GRADE-81


2 Pulverising the local soil in place, spreading with rotavator duly adding the specified
quantity of inorganic Compound RBI Grade 81 as approved by CRRI, mixing thoroughly,
sprinkling desired quantity of water, grading with motor grader and compacting with the
road roller at OMC to the desired density for improving the subgrade & shoulders. (The
cum 1541.00
laboratory CBR of the compacted soil shall not be less than 10)
For soils having WL more than 50, with 2% of inorganic Compound like RBI Grade 81 by
weight of Soil.

Page 208 of 350


38.15.2 RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising and mixing
80% Gravel Soil and 20% Aggregates (30mm nominal size), spreading with rotavator duly
adding the specified quantity of inorganic Compound RBI GRADE-81 as specified by IRC:
37-2012, mixing thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for preparing the Base /
Sub Base Layer (The Laboratory CBR of the gravel soil shall not be less that 9%) including
cost of all materials, labour, HOM of Machineries complete as per specification.

38.15.2. RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising and mixing
1 80% Gravel Soil and 20% Aggregates (30mm nominal size), spreading with rotavator duly
adding the specified quantity of inorganic Compound RBI GRADE-81 as specified by IRC:
37-2012, mixing thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for preparing the Base /
cum 1986.00
Sub Base Layer (The Laboratory CBR of the gravel soil shall not be less that 9%) including
cost of all materials, labour, HOM of Machineries complete as per specification.
With 2% inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material :

38.15.2. RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising and mixing
2 80% Gravel Soil and 20% Aggregates (30mm nominal size), spreading with rotavator duly
adding the specified quantity of inorganic Compound RBI GRADE-81 as specified by IRC:
37-2012, mixing thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for preparing the Base /
cum 2710.00
Sub Base Layer (The Laboratory CBR of the gravel soil shall not be less that 9%) including
cost of all materials, labour, HOM of Machineries complete as per specification.
With 3% inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material

38.15.2. RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising and mixing
3 80% Gravel Soil and 20% Aggregates (30mm nominal size), spreading with rotavator duly
adding the specified quantity of inorganic Compound RBI GRADE-81 as specified by IRC:
37-2012, mixing thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for preparing the Base /
cum 3435.00
Sub Base Layer (The Laboratory CBR of the gravel soil shall not be less that 9%) including
cost of all materials, labour, HOM of Machineries complete as per specification.
With 4% inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material

38.15.2. RBI GRADE-81 (Gravel soil & aggregate mix material) Pulverising and mixing
4 80% Gravel Soil and 20% Aggregates (30mm nominal size), spreading with rotavator duly
adding the specified quantity of inorganic Compound RBI GRADE-81 as specified by IRC:
37-2012, mixing thoroughly, sprinkling desired quantity of water, grading with motor grader
and compacting with vibratory roller at OMC to the desired density for preparing the Base /
cum 4157.00
Sub Base Layer (The Laboratory CBR of the gravel soil shall not be less that 9%) including
cost of all materials, labour, HOM of Machineries complete as per specification.
With 5% inorganic Compound like RBI GRADE 81 by weight of Soil & Aggregate Mix
Material:

38.15.3 RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material) Pulverising and
mixing coarse Aggregates (10mm & down size) and Fine aggregate (2.36mm & down size)
in 1:1 proportion, spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing thoroughly, sprinkling
desired quantity of water, grading with motor grader and compacting with vibratory roller at
OMC to the desired density for preparing the Stabilized Base / Sub Base Layer including
cost of all materials, labour, HOM of Machineries complete as per specification.

Page No. 283

Page 209 of 350


38.15.3. RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material) Pulverising and
1 mixing coarse Aggregates (10mm & down size) and Fine aggregate (2.36mm & down size)
in 1:1 proportion, spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing thoroughly, sprinkling
desired quantity of water, grading with motor grader and compacting with vibratory roller at
cum 3122.00
OMC to the desired density for preparing the Stabilized Base / Sub Base Layer including
cost of all materials, labour, HOM of Machineries complete as per specification.
With 2% inorganic Compound like RBI GRADE 81 by weight of Coarse & Fine
Aggregate Mix Material

38.15.3. RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material) Pulverising and
2 mixing coarse Aggregates (10mm & down size) and Fine aggregate (2.36mm & down size)
in 1:1 proportion, spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing thoroughly, sprinkling
desired quantity of water, grading with motor grader and compacting with vibratory roller at
OMC to the desired density for preparing the Stabilized Base / Sub Base Layer including cum 4104.00
cost of all materials, labour, HOM of Machineries complete as per specification.
With 3% inorganic Compound like RBI GRADE 81 by weight of Coarse & Fine
Aggregate Mix Material

38.15.3. RBI GRADE -81 (Coarse Aggregate & Fine Aggregate Mix Material) Pulverising and
3 mixing coarse Aggregates (10mm & down size) and Fine aggregate (2.36mm & down size)
in 1:1 proportion, spreading with rotavator duly adding the specified quantity of inorganic
Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing thoroughly, sprinkling
desired quantity of water, grading with motor grader and compacting with vibratory roller at
OMC to the desired density for preparing the Stabilized Base / Sub Base Layer including cum 5068.00
cost of all materials, labour, HOM of Machineries complete as per specification.
With 4% inorganic Compound like RBI GRADE 81 by weight of Coarse & Fine
Aggregate Mix Material

38.15.4 RBI GRADE -81 - Cold In Place recycling Pulverising and mixing the
existing worn-out/ damaged road with recycler/milling machine duly adding the specified
quantity of inorganic Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader and compacting
with vibratory roller at OMC to the desired density for preparing the Stabilized Base
including cost of all materials, labour, HOM of Machineries complete as per specification.
(RAP-Reclaimed Asphalt Pavement)

38.15.4. RBI GRADE -81 - Cold In Place recycling Pulverising and mixing the
1 existing worn-out/ damaged road with recycler/milling machine duly adding the specified
quantity of inorganic Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader and compacting
with vibratory roller at OMC to the desired density for preparing the Stabilized Base cum 2813.00
including cost of all materials, labour, HOM of Machineries complete as per specification.
(RAP-Reclaimed Asphalt Pavement) With 2% inorganic Compound like RBI
GRADE 81 by weight of Milled Material:

38.15.4. RBI GRADE -81 - Cold In Place recycling Pulverising and mixing the
2 existing worn-out/ damaged road with recycler/milling machine duly adding the specified
quantity of inorganic Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader and compacting
with vibratory roller at OMC to the desired density for preparing the Stabilized Base
cum 3777.00
including cost of all materials, labour, HOM of Machineries complete as per specification.
(RAP-Reclaimed Asphalt Pavement) With 3% inorganic Compound like RBI
GRADE 81 by weight of Milled Material

Page 210 of 350


38.15.4. RBI GRADE -81 - Cold In Place recycling Pulverising and mixing the
3 existing worn-out/ damaged road with recycler/milling machine duly adding the specified
quantity of inorganic Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader and compacting
with vibratory roller at OMC to the desired density for preparing the Stabilized Base cum 4742.00
including cost of all materials, labour, HOM of Machineries complete as per specification.
(RAP-Reclaimed Asphalt Pavement) With 4% inorganic Compound like RBI
GRADE 81 by weight of Milled Material

38.15.4. RBI GRADE -81 - Cold In Place recycling Pulverising and mixing the
4 existing worn-out/ damaged road with recycler/milling machine duly adding the specified
quantity of inorganic Compound RBI GRADE-81 as specified by IRC: 37-2012, mixing
thoroughly, sprinkling desired quantity of water, grading with motor grader and compacting
with vibratory roller at OMC to the desired density for preparing the Stabilized Base cum 5707.00
including cost of all materials, labour, HOM of Machineries complete as per specification.
(RAP-Reclaimed Asphalt Pavement) With 5% inorganic Compound like RBI
GRADE 81 by weight of Milled Material:

38.16 RBI GRADE -81 --- Cutting the pothole to regular shape, trimming to provide firm vertical
faces, removing all loose materials, cleaning of surface, filling with a mix of aggregates
(40mm downsize) & local soil (except BC Soil) in 1:1 proportion duly adding 2 % of
Inorganic compound RBI Grade 81, mixing thoroughly, compacting & finishing etc.,
complete in WBM layers for Pothole/Patch repairs.
Methodology and Construction :
Stabilization using RBI Grade 81 (the process of improving the
engineering properties of a material by means of the addition of RBI
Grade 81) is subject to the quality of materials available and the impact of the environment
(traffic, climate, etc.) on the structural design. Stabilization with RBI Grade 81 endeavors to
increase the quality of the project and reduce construction costs by improving the properties
of substandard, readily available material to comply with the relevant specifications.
1. Materials
Soil or Gravel
Stabilizer agent, RBI Grade 81
Should be kept under cover and protected from moisture from the time of purchase to the
time of use. If material has been left exposed to environmental elements, consult a RBI
Grade 81 representative. It is preferable to stabilize a soil with a continuously smooth
gradation curve from the maximum particle size to the smallest particle size with no excess cum 2903.00
or lack in certain particles. This will ensure better interlocking capabilities of the soil
particles resulting in increased density and strength of the soil. It is recommended that the
soil material have sufficient fine material (< 2.00 mm) to effectively stabilize the material
with RBI Grade 81.
2. Water
Water used should be free from harmful substances that may affect
the setting and hardening process of the stabilizer. Water that is thought to encourage
adverse reactions should be tested for compatibility with RBI Grade 81.
3. Construction procedures
The stabilization of soil requires the careful programming of several
operations:
a. Pulverization, which may require initial scarifying
b. Addition of stabilizer
c. Thorough mixing of soil, stabilizer and added water
d. Laying, spreading and compacting
e.Curing - (minimum of 7 days curing is necessary)
Thus efficient planning of the side operations is necessary to minimize the time between
mixing and compacting. The periods of working should also be consistent with the climatic
Page No. 284
38.17 Soilfix Chemical compound --- Cutting the pothole to regular shape, trimming to provide
firm vertical faces, removing all loose materials, cleaning of surface, filling with a mix of
aggregates (40mm downsize) & local soil (except BC Soil) in 1:1 proportion duly adding 0.5
% of Soilfix Chemical compound, mixing thoroughly, compacting & finishing etc., complete
in WBM layers for Pothole/Patch repairs. cum 3450.00
Ref: IRC SP 20 : 2002 : RURAL ROADS MANUAL AND MORT&H
SPECIFICATIONS FOR ROAD AND BRIDGE WORKS ( 4TH
REVISION )

Page 211 of 350


38.18 CLAY HOLLOW BRICKS (Extruded) Providing and constructing thick
clay hollow brick masonry in cement mortar 1:6 using horizontal perforated clay hollow
brick with minimum crushing strength of 35 kg/sqcm including scaffolding, curing etc.,
complete as directed at all levels. STANDARDS
Minimum Crushing Strength 35 Kg/Sqcm.
U- Value 1.1 W/SqmK.
Density 695 Kg /Cum.
Water absorption <20 %.
Reduces the energy consumption and hence help to maintain
comfortable temperature inside.
Natural & Green Building Product.
*Ref: - IS 3952 Guidelines for use of horizontally perforated clay
bricks.
Construction Methodology
* All concrete surfaces of beams and columns coming in contact
with brick work is to be hacked.
* Pre wet the bricks before construction.
* Use cement mortar slurry of 1:2 on the hacked surface to create a
roughened surface for proper bonding.
* Use silt free (less than 5%) sieved clean sand for mortar.
* Place the marker course of brick (1st course) after checking the
vertical & horizontal alignment. And also mark the vertical course
up to beam bottom on the column to maintain the equal mortar
joints. * Mix mortar in proportion of 1:6
for 200 & 150 mm thick walls and 1:4 for 100 mm thick walls using Farma box (Equal to 1
cement bag) for measuring sand and a measuring can to standardize quantum of water to get
a consistent mix. Mix well for uniformity. Mix mortar in small manageable quantities and
use it within ½ an hour.
* Mortar joints should be 10 to 12 mm for both vertical and horizontal joints. The joints
should be neatly pointed using an Aluminum Straight edge.
* Give concrete band of 1:2:4 with 8 mm steel (2 Nos.) in a 100 mm thick wall at every 1
meter height.
* Adjuster course in concrete 1:2:4 should be laid two in courses below the beam and not
38.18.1 above
CLAYthe top mostBRICKS
HOLLOW courses. (Extruded) -- of size 400 x 200 x 200mm
Providing and constructing thick clay hollow brick masonry in cement mortar 1:6 using
horizontal perforated clay hollow brick with minimum crushing strength of 35 kg/sqcm Sqm 822.00
including scaffolding, curing etc., complete as directed at all levels.
_do_ of size 400 x 200 x 200mm
38.18.2 CLAY HOLLOW BRICKS (Extruded) -- of size 400 x 200 x1 50mm
Providing and constructing thick clay hollow brick masonry in cement mortar 1:6 using
horizontal perforated clay hollow brick with minimum crushing strength of 35 kg/sqcm Sqm 642.00
including scaffolding, curing etc., complete as directed at all levels.
_do_ of size 400 x 200 x1 50mm
38.18.3 CLAY HOLLOW BRICKS (Extruded) -- of size 400 x 200 x 100mm
Providing and constructing thick clay hollow brick masonry in cement mortar 1:6 using
horizontal perforated clay hollow brick with minimum crushing strength of 35 kg/sqcm Sqm 622.00
including scaffolding, curing etc., complete as directed at all levels.
_do_ of size 400 x 200 x 100mm
Page No. 290

Page 212 of 350


38.19 Dry Lean Concrete (DLC) for Profile correction of existing
bituminous road surface before carrying out White Topping
Dry Lean Concrete (DLC) M-5 for Profile correction of existing
bituminous road surface before carrying out White Topping Construction
of dry lean cement concrete sub base layer over existing scarified (to
the depth of 25 mm with miller machine includes mobilization, diesel
and operating cost, includes cleaning by air blower/sand blasting/
brooming etc.) bituminous road surface with coarse and fine aggregate
conforming to IS 383, the size of coarse aggregate not exceeding 25mm,
aggregate cement ratio not to exceed 15:1, aggregate gradation after
blending to be as per Table 600-1, cement content not less than 160
kg/cum, optimum moisture content to be determined during trial length
construction, concrete strength not to be less than 10 Mpa at 7 days, cum 3821.00
mixed in ready mix concrete plant or a batching plant (to ensure
consistency) transported to site, laid to the depth of 40 mm - 50 mm
with a fixed form paver with electric sensor, having gang mounted
vibrators equally spaced with variable rpm and atleast three integral
steel tubes with 8-10 tonnes vibratory rollers for screeding, levelling,
compaction, finishing and curing, includes lifting/shifting charges of
paver, as per specifications complete, ( cement 160kgs. coarse
aggregate= 0.86 cum, Fine aggregate=0.58cum)
MORTH specifications No.601.

38.20 WHITE TOPPING


Page No. 291
38.20.1 Providing and laying White Topping as per IRC:SP76-2008 over
bituminous surface (Existing bituminous surface preparation to be done
if necessary either by milling or levelling course with BM/DBM to correct
surface profile and to be paid separately) with unreinforced M-40 grade
pavement quality concrete (PQC)using polymeric synthetic fibre as per ASTM (1116) such
as polyester / polyethylene / polypropylene
at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher
as per approved mix design to achieve minimum flexural strength or
modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum
water cement ratio to 0.40, transported to site, laid with mechanical
paver finisher, spread, vibrated, compacted and finished in a continuous
operation to the lines and grades as per drawing, texture finishing of
surface, spraying two layers of curing compound, curing with water cum 7443.00
sprayed on hessian cloth coverd over concrete surface, groove cutting
to a depth of 1/3 of the slab depth and of width 3-5 mm as per design (grove cutting to be
paid separately). For thin white topping and ultra thin
white topping the groove cutting shall be 1.25mm x 1.25m grid) including
cost of all materal, side from work, labour and HOM of machineries etc.
complete as per specifications.
- do - with unreinforced M40 grade pavement quality concrete using
43 grade OPC @ 420 kg/cum, coarse aggregate, fine aggregate and
admixture confirming to IS 9130-1999 (R-2004)

Page 213 of 350


38.20.2 Providing and laying White Topping as per IRC:SP76-2008 over
bituminous surface (Existing bituminous surface preparation to be done
if necessary either by milling or levelling course with BM/DBM to correct
surface profile and to be paid separately) with unreinforced M-40 grade
pavement quality concrete (PQC) using polymeric synthetic fibre as per ASTM (1116) such
as polyester / polyethylene / polypropylene
at 1.20 kg/cum, mixed in batching and mixing plant or weigh batcher
as per approved mix design to achieve minimum flexural strength or
modulus of rupture of concrete 4.50 MPa at 28 days limiting maximum
water cement ratio to 0.40, transported to site, laid with mechanical
paver finisher, spread, vibrated, compacted and finished in a continuous
operation to the lines and grades as per drawing, texture finishing of
surface, spraying two layers of curing compound, curing with water
sprayed on hessian cloth coverd over concrete surface, groove cutting cum 6977.00
to a depth of 1/3 of the slab depth and of width 3-5 mm as per design
(grove cutting to be paid separately). For thin white topping and ultra thin
white topping the groove cutting shall be 1.25mm x 1.25m grid) including
cost of all materal, side from work, labour and HOM of machineries etc.
complete as per specifications.
- do - with un-reinforced M-40 grade Pavement Quality Concrete (PQC)
using 53 grade OPC at 315 kg/cum and cementitious material ground
granulated blast furnace slag at 105 kg/cum, satisfying IS:12089-
1987(R2004) coarse aggregate fine aggregate, admixture conforming
to IS:9103-1999(R2008)

38.20.3 Providing and laying White Topping as per IRC:SP76-2008 over


bituminous surface (Existing bituminous surface preparation to be done
if necessary either by milling or levelling course with BM/DBM to correct
surface profile and to be paid separately) with unreinforced M-40 grade
pavement quality concrete (PQC)using polymeric synthetic fibre as per
ASTM (1116) such as polyester / polyethylene / polypropylene at 1.20
kg/cum, mixed in batching and mixing plant or weigh batcher as per
approved mix design to achieve minimum flexural strength or modulus of
rupture of concrete 4.50 MPa at 28 days limiting maximum water cement
ratio to 0.40, transported to site, laid with mechanical paver finisher,
spread, vibrated, compacted and finished in a continuous operation
to the lines and grades as per drawing, texture finishing of surface,
spraying two layers of curing compound, curing with water sprayed on
cum 6900.00
hessian cloth coverd over concrete surface, groove cutting to a depth of 1/3 of the slab depth
and of width 3-5 mm as per design (grove cutting
to be paid separately). For Thin white Topping and ultra thin white
topping the groove cutting shall be 1.25mm x 1.25m grid) including
cost of all materal, side from work, labour and HOM of machineries
etc. complete as per specifications.
- do - with un-reinforced M-40 grade pavement quality concrete (PQC)
using 53 grade OPC at 357 kg/cum and cementitious material fly ash,
at 63 kg/cum, satisfying IS:3812-2013(Part-1) coarse aggregate fine
aggregate, admixture conforming to IS:9103-1999(R2008)

Page 214 of 350


38.21 Providing groove cutting for width of 4mm - 6mm and 1/3rd depth of
PQC Whitetopping within 8-10 hrs of placing/finishing of PQC including cost of cutting
machine, generators, HOM of machinery, blades, coolant etc., including cleaning of groove
and providing sand and hot bituminous or equivalent approved sealant filling etc., including
cost of conveyance of all materials, labour, lead and lift charges and all other incidental
charges as per drawing and as per specifications.Cement Concrete White Topping/Concrete
Overlay as per IRC: SP: 76-2008 White topping is defined as a PCC (Portland Cement
Concrete) overlay constructed on the top of an existing bituminous pavement. Thus, it is a
rehabilitation or structural strengthening alternative on bituminous pavement. Rutting of
pavement is a real problem in a country like India,
with heavy truck loads, operating under frequent start/stop conditions. It is commonly
applied where rutting of bituminous pavements is a recurring problem, particularly in case of
city roads. Concrete over lays offers the potential for extended service life, increased
structural capacity, reduced maintenance requirements and lower life-cycle costs when m 100.00
compared with bituminous overlay alternative Concrete overlays have been used on both
bituminous (flexible) pavements since 1918 and existing concrete pavement since
1913.White topping is classified into three types, based on the thickness of overlay, types of
interface provided i.e., degree of bonding between the underlying bituminous layers with
PCC overlay & thickness of overlay. They are:
i) Conventional White topping – which consists of PCC overlay of thickness 200 mm or
more, which is designed & constructed without consideration of any bond between existing
overlay & underlying bituminous layer (without assuming any composite action). ii) Thin
White topping (TWT) – which has PCC overlay between 100 – 200 mm. It is designed either
considering bond between overlay & underlying bituminous layer or without consideration
of bond. High strength concrete (M 40 or higher) is normally used to take care of flexure
requirement. Joints are at shorter spacing of 0.6 to 1.25 m.
iii) Ultra-Thin White topping (UTWT) – which has PCC overlay of less than 100 mm.
Bonding between overlay & underlying bituminous layer is mandatory. To ensure this, the
Page No. 292
38.22 Use of GEO Textiles / GEO fabrics in road pavements and subsurface drainage works.
Providing and Inserting Prefabricated Vertical Drain, core with synthetic material and
wrapped with Non-woven geotextile 120GSM in very soft clay for quick consolidation.
Ref: IRC SP 59 : GUIDELINES FOR USE OF GEO TEXTILES IN ROAD PAVEMENT S
AND ASSOCIATED WORKS- 2002
Technical Data;
-do- with 100mm width ,thickness = 4mm,mass per linear meter 90g/m,with tensile strength
=2.0 KN
-do –with 100mm width,thickness =5.2 mm,mass per linear meter 110g/m,with tensile
strength = 2.4 KN
Application Methodology;
Vertical drains may be installed employing either vibratory or static m 90.00
methods. In either case, the drain is enclosed in a tubular steel mandrel of small cross-
sectional area usually 50x125mm. A small steel anchor plate is attached to the drain at the
bottom of the mandrel. The mandrel is then driven in to the soil either with a static or
vibratory rig. When the design depth is reached, the mandrel is extracted. The anchor plate
retains the drain in the soil. When the mandrel is fully extracted the drain is cut off a new
anchor plate is installed and the process begins again. These are used in Land reclamation
projects, Construction of highways ,railways ,airfields and dykes,Ports and harbor
construction, Development of industrial sites ,Mitigation of liquefaction,etc..

38.23 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
Technical Data :
_ do_with GSM 150,1.3mm thickness,Grabtensile strength 540N,
Puncture strength 315N,Trapezoidal tear 230N,Apparent opening size 180 μm,
_do_200Gsm,1.6 mm thickness,Grabtensile strength
720N,Puncture strength 400N,Trapezoidal tear 300N,Apparent opening size 150μm
_do_250Gsm,1.8 mm thickness, Grabtensile strength 865N,Puncture
strength 525N,Trapezoidal tear 360N,Apparent opening size 150μm
_do_300Gsm,1.9 mm thickness, Grabtensile strength 1010N,Puncture strength
650N,Trapezoidal tear 415N, Apparent opening size 120μm
_do_400GSM,2.5 mm thickness, Grabtensile strength1325N,Puncture strength
785N,Trapezoidal tear 510N, Apparent opening size 106μm
_do_500GSM,2.9 mm thickness, Grabtensile strength1570N,Puncture strength

Page 215 of 350


38.23.1 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
-do-with GSM 150,1.3mm thickness,Grabtensile strength 540N, Puncture strength Sqm 100.00
315N,Trapezoidal tear 230N,Apparent opening size 180 μm,

38.23.2 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
-do- GSM200G,1.6 mm thickness,Grabtensile strength 720N,Puncture strength Sqm 105.00
400N,Trapezoidal tear 300N,Apparent opening size 150μm

38.23.3 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
-do-GSM 250,1.8 mm thickness, Grabtensile strength 865N,Puncture strength Sqm 110.00
525N,Trapezoidal tear 360N,Apparent opening size 150μm

38.23.4 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
-do- GSM 300,1.9 mm thickness, Grabtensile Sqm 115.00
strength 1010N,Puncture strength 650N,Trapezoidal tear 415N, Apparent opening size
120μm

38.23.5 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
-do-400 GSM,2.5 mm thickness, Grabtensile strength1325N,Puncture strength Sqm 125.00
785N,Trapezoidal tear 510N, Apparent opening size 106μm

38.23.6 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
-do- 500GSM ,2.9 mm thickness, Grabtensile strength1570N,Puncture strength Sqm 135.00
910N,Trapezoidal tear 600N, Apparent opening size 90μm

38.23.7 Providing and Laying Needle punched and mechanically bonded Nonwoven Geotextile
indigenously manufactured from high quality synthetic fibres on the prepared subgrade for
separator cum filtration cum drainage application with necessary overlaps as per drawing.
-600GSM,3.4 mm thickness, Grabtensile strength1980KN,Puncture sqm 145.00
strength 1080N, Trapezoidal tear 705N, Apparent opening size =70μm

Page No. 294

Page 216 of 350


38.24 Providing and Laying rope Gabions, indigenously manufactured from high strength rope for
slope protection and erosion control for river bank and sea-shore protection. Exclusive of
providing & filling stones.
Technical Data;
do - size 1M x1M x 1M, aperture 150mm x 150mm, Tensile strenth
9500Kg/m, Punching shear strenth 5200Kg
-do - size 1M x1M x 2M, aperture 100mm x 100mm, Tensile strenth 14000Kg/m, Punching
shear strenth 6200Kg
-do-size 1M x1M x 3M, aperture 100mm x 100mm, Tensile strenth
14000Kg/m, Punching shear strenth 6200Kg,
Application Methodology;
Copper and polymer Gabions are rectangular or cylindrical baskets
fabricated from polymer meshes and usually filled with stone and used for structural
purposes such as retaining walls, revetments, slope protection,and similar applications.
These are fabricated from ropes of suitable diameter into a box like form with required size
and apertures. These are used in application like River bank protection, revetment, toe-
walls,aprons,groynes,spurs,channel linings, sea shore protection, seawalls, Anti-erosion
structures,etc.

38.24.1 _do_ copper and synthetic rope gabion of size 1mx1mx1m, aperture 100mm x 100mm Box 1300.00
38.24.2 _do_ copper and synthetic rope gabion of size 1mx1mx2m, aperture 100mm x 100mm Box 2400.00
38.24.3 _do_ copper and synthetic rope gabion of size 1mx1mx3m, aperture 100mm x 100mm Box 3600.00
Page No. 295
38.25 Providing and Synthetic Biaxial Geogrid indigenously manufactured from selected high
tenacity synthetic yarn with high molecular weight (> 25000 g/mol), and low carboxyl end
group (<30mmol/kg) for soil reinforcement application for stabilisation, requirement of
geogrid strength in both direction with granular fill.
Technical Data;
-do- ultimate tensile strenth 30Kn/m in MD and CMD, Tensile strenth at 2% elongation
6Kn/m in MD and 6Kn/m in CD, aperture size in MD and CD 26X26mm.
-do- ultimate tensile strenth 40Kn/m in MD and CMD, Tensile strenth at 2% elongation
7.5Kn/m in MD and 7.5Kn/m in CD, aperture size in MD and CD 25X25mm
-do- ultimate tensile strenth 60Kn/m in MD and CMD, Tensile strenth at 2% elongation
9Kn/m in MD and 7.5Kn/m in CD, aperture size in MD and CD 25X25mm
-do- ultimate tensile strenth 90Kn/m in MD and CMD, Tensile strenth at 2% elongation
11Kn/m in MD and 9Kn/m in CD, aperture size in MD and CD 23X23mm
Application Methodology;
Biaxial geogrids are designed for applications where strength
requirement is in both directions. They are used in reinforcement of
granular roadbase and subbase, area stabilization, trackbed
stabilization, load transfer platforms,etc.

38.25.1 _do_ with 30 x 30 Kn/m Ultimate Tensile Strength Sqm 125.00


38.25.2 _do_ with 40 x 40 Kn/m Ultimate Tensile Strength Sqm 145.00
38.25.3 _do_ with 60 x 60 Kn/m Ultimate Tensile Strength Sqm 180.00
38.25.4 _do_ with 90 x 90 Kn/m Ultimate Tensile Strength Sqm 220.00
Page No. 296

Page 217 of 350


38.26 Providing and Synthetic Uniaxial Geogrid, indigenously manufactured from selected high
tenacity synthetic yarn with high molecular weight (> 25000 g/mol), and low carboxyl end
group (<30mmol/kg) for reinforced soil wall and slope application with granular fill as per
design prepared by technology provider of reinforced earth wall and slope.
Technical Data:
-do- with ultimate tensile strenth 40Kn/m in MD and 20Kn/m in CMD, aperture size in MD
and CD 30X25mm,
-do- with ultimate tensile strenth 60Kn/m in MD and 20Kn/m in CMD, aperture size in MD
and CD 30X25mm,
-do-with ultimate tensile strenth 80Kn/m in MD and 30Kn/m in CMD, aperture size in MD
and CD 30X25mm,
-do- with ultimate tensile strenth 100Kn/m in MD and 30Kn/m in CMD, aperture size in MD
and CD 30X23mm,
-do- with ultimate tensile strenth 120Kn/m in MD and 30Kn/m in CMD, aperture size in MD
and CD 30X23mm,
-do- with ultimate tensile strenth 150Kn/m in MD and 30Kn/m in CMD, aperture size in MD
and CD 30X23mm,
-do-with ultimate tensile strenth 200Kn/m in MD and 30Kn/m in CMD, aperture size in MD
and CD 30X22mm,
-do- with ultimate tensile strenth 250Kn/m in MD and 30Kn/m in CMD, aperture size in MD
and CD 30X20mm,
-do-with ultimate tensile strenth 35Kn/m in MD and 60Kn/m in CMD, Tensile strenth at 2%
elongation 8Kn/m in MD and 9Kn/m in CD, aperture size in MD and CD 25X25mm
-do-with ultimate tensile strenth 40Kn/m in MD and 80Kn/m in CMD, Tensile strenth at 2%
elongation 8Kn/m in MD and 12Kn/m in CD,
Application Methodology:
Uniaxial geogrids are available in a range of tensile strength and are
suitable for applications, which require strength in one direction, these are used in reinforced
soil walls,steep slopes and basal reinforcement of embankments,veneer reinforcement,etc..

38.26.1 _do_ with 40 Kn/m Ultimate Tensile Strength Sqm 120.00


38.26.2 _do_ with 60 Kn/m Ultimate Tensile Strength Sqm 135.00
38.26.3 _do_ with 80 Kn/m Ultimate Tensile Strength Sqm 155.00
38.26.4 _do_ with 100 Kn/m Ultimate Tensile Strength Sqm 180.00
38.26.5 _do_ with 120 Kn/m Ultimate Tensile Strength Sqm 205.00
38.26.6 _do_ with 150 Kn/m Ultimate Tensile Strength Sqm 230.00
38.26.7 _do_ with 200 Kn/m Ultimate Tensile Strength Sqm 290.00
38.26.8 _do_ with 250 Kn/m Ultimate Tensile Strength Sqm 330.00
Page No. 297
38.27 Paving Fabric
Providing and Laying Needle punched and mechanically bonded Nonwoven Paving Fabric
indigenously manufactured from high quality Synthetic staple fibres having grab tensile
strength of 39Kg , and melting point of 150 °C confirming to ASTM / Morth sec - 700 over
a tack coat of paving grade bitumen 80-100 preparation, laid at the rate of 1 kg per sq.mtr
over thoroughly cleaned and repaired surface to surface with pneumatic roller to maximize
paving fabric contact with pavement surface as per drawing.
Application Methodology:
Paving fabric is a strong layer of fabric is applied under asphalt to
minimize surface water infiltration and prevent existing cracks in the Sqm 140.00
road from surfacing to enhance the performance of pavement. The
Barrier function refers to the prevention of fluid movement across theplane of the geotextile.
A nonwoven geotextile provides a barrier function when saturated with an impermeable
material, like bitumen. It Retards the propagation of cracks, Reduced the required design
overlay thickness, Extends the life of the overlay and the pavement section,These can be
used as asphalt over lay on flexible pavement a nd rigid pavement –a layer of DBM/BC
should be provided on rigid pavement before laying the paving fabric.

Page No. 298

Page 218 of 350


38.28 Providing and construction of steel wire mesh Gabion retaining wall for
retaining walls with Mechanically woven double twisted, mechanically
selvedge, Zinc+PVC coated gabion of mesh type 10x2, wire dia
2.7/3.7mm (inner/outer diameter), selvedge wire dia 3.4/4.4mm as per
standards (EN/IS 16014) with diapragms (partitions), in every 1M for
Gabions of length higher then 1.5M as per standards, from manufacturers
of proven experience in similar technology, including filling of rubble of
size 150mm to 250mm at site including packing compactness to lins and
levels in the exposed face of masonry, in dry condition, simultaneously
during the course as per construction guidelines by the department/
installtion guideline manufacturer, including all lead, lift and labour etc.
complete. (In case of under water installation, the approrite provision
for crane, extra labour etc., need to be taken extra).
Application Methodology:
Metal Gabion is comprised double twisted hexagonally woven steel wire
mesh with zinc galvanized and PVC coated compartmented baskets
with a rectangular box shape. The compartments are of equal dimensionand are formed by
internal diaphragms. The compartment is filled with
natural stone at the site of use,to form flexible,permeable,monolithic
structures for earth retension and the diaphragms assure minimum
stone migration within the basket. Thus providing even distribution of
the stone even in abnormal conditions,and adding strength to the
container to help retain its rectangular shape during the filling
operation,depending on the application and requirement,these gabions
can be manufactured in different size i.e.length and width with diaphragm
mat every 1.0 m length.These are used in application like Earth control
and soil conservation,Retaining structures/walls,Rock wall protection
netting,Protection of highways/Railways,Barriers at the river,Bridges and
culvert protection,Marine and sea wall protection,Lining of steep slopes
or slopes protection,Revetments for lakes and sea shores ,Lining of
canals and dams,etc.

38.28.1 _do- for Gabion box size of 1x1x1 cum 2900.00


38.28.2 _do- for Gabion box size of 1.5x1x1 cum 2550.00
38.28.3 _do- for Gabion box size of 2x1x1/1 diaphragm cum 2650.00
38.28.4 _do- for Gabion box size of 3x1x1/2 diaphragm cum 2450.00
38.28.5 _do- for Gabion box size of 4x1x1/3 diaphragm cum 2400.00
38.28.6 _do- for Gabion box size of 1x1x0.5 cum 4200.00
38.28.7 _do- for Gabion box size of 1.5x1x0.5 cum 3650.00
38.28.8 _do- for Gabion box size of 2x1x0.5/1 diaphragm cum 3700.00
38.28.9 _do- for Gabion box size of 3x1x0.5/2 diaphragm cum 3600.00
38.28.1 _do- for Gabion box size of 4x1x0.5/3 diaphragm
cum 3500.00
0
Page No. 299

Page 219 of 350


38.29 BORE PACKING for pipe joints
Providing & applying high strength non shrink free flow grout (confirming to BS 1881-Part
116 : 1983)comprising of blend of portland cement, graded fillars and chemical additives
which impart controlled expansion in the plastic state duly minimizing water demand.
(Minimum 25mm thickness around the pipe)
Standards
1. Compressive strength for 28 days 78 N/sqmm
2. Flowable (Water powder ratio 0.18)
3. Pourable (Water powder ratio 0.165)
4. Tensile strength for 28 days 3.5 N/ sqmm
5. Flexural strength for 28 days 10 N/ sqmm No 330.00
6. Unrestrained expansion – 2 to 4 % in the plastic state
Methodology :
Non shrink free flow grout shall be added to the water in the ratio of 25 Kg : 4.125 ltrs of
water for pourable condition and for flowable condition 4.5 ltrs by using heavy duty slow
speed grill (400 to 500 RPM) fitted with the suitable peddle for 5 minutes. To get the best
result the mixed grout should be placed and used in 20 minutes after the mixture.

38.30 PROVIDING TRAPEZOIDAL PROFILED SHEET


Providing and installing of pre painted Galvolume iron Trapezoidal
profiled sheet of approved make 1060 mm width (1000 mm cover width), 28-30 mm crest
height with crest distance of 200 mm c/c with 2 ribs at the centre for stiffening. The total
coated thickness (TCT) of the sheet will be 0.47 mm +/- 0.02 mm tolerance Zinc-Alu Alloy
Sqm 770.00
coating AZ150 gsm as per ASTM 1397/A755-550 mpa steel grade, 5-7 microns epoxy
primer on both side of the sheet and polyester top coat 20-22 microns using self drilling/self
tapping screws of 25 mm length, to be fixed over the existing purlins, rafters, channels and
trusses.

Page No. 300


38.31 Providing and installing of approved make pre painted Galvalume iron Accessories, like,
plain, ridges, plain gutter, plain flashing, corner Trim, etc. The total coated thickness (TCT)
of the sheet shall be 0.47 mm +/- 0.02 tolerance mm Zinc-Alu Alloy coating AZ 150 gsm as
per ASTM 1397/755 -550 mpa steel grade, 5-7 microns epoxy primer on both side of the Sqm 740.00
sheet and polyester top coat 20-22 microns using self drilling / self tapping screws of 25 mm
length. (width upto 500-600 mm only), to be fixed over the existing purlins, rafters, channels
and trusses.

38.33 Stone Cleaning _ Cleaning Unpolished granite surface by application of Proven, Readily
Biodegradable, VOC free, Stabilised, Non-Dilutable, Water Base & Ready to Use (RTU)
liquid chemical formulation with no contact time restriction over the heavily soiled
unpolished granite stone surface using a 30 psi spraying equipment / Roller / Brush
spreading & thoroughly wetting the chemical @ minimum 0.25 ltr to cover 1 sq.mtr on the
surface to be treated. Allow the penetration & chemical reaction time for a minimum of 24
hrs time. The surface is then low pressure water rinsed with rotary nozzle @ 700 psi after
scrubbing the surface till all the organic & inorganic contamination, dirt, hydro-carbon soils,
algae & rust stains from both the surface & pore of the substrate is completely removed, the
stone is returned to its natural colour & permeability restored. The formulation being used
should be free from corrosive acids such as Hydrochloric or Muriatic acid, Hydrofluoric
acid, caustics or Sodium Hydroxide, bleach or Sodium Hypochlorite, abrasives and
petroleum distillates. No free Acids or Alkalis to be used.The process should include
all chemical materials, labour, application tools, spraying equipment, Low pressure washer,
safety procedures, hand gloves, face shields, goggles, protective wear clothing, scaffolding
& working platform, lead & lift, transportation, all incidental charges etc., complete as per
the directions of the Engineer-in-charge of the work.
Page No. 302

Page 220 of 350


38.33.1 Stone cleaning using biodegradable liquid solution
Cleaning granite surface by using aproved quality bio-degradable liquid solution
(Ammonium Hydrogendifloride solution) as per the directions of Engineer incharge of the
works. The cost of works includes cost of materials, HOM of machineries, labour charges
etc. complete.
Methodology :
1) The solution to be used shall be free from hydrofloric acid, muriatic acid, caustic, bleach,
abrasive or petroleum distillates and the neutral pH should be 5.0 to 5.5. Sqm 408.00
2) The surface is to be washed first with water pressure of 130psi/
sec, until the deposit of dirt, hydro carbon soils and algae from the
surface and the pores of the surface are completely removed.
3) Cleaned surface to be dried for 24 hours.
4) Bio-degradable solution shall be applied over the dry surface.
5) All safety measures shall be taken during the process of application.

38.34 SLIDING WINDOWS (2 shutters) or equivalent sliding Windows (suitable for residential
and non-residential buildings) Providing and fixing of Sliding Windows made of
Galvanized Steel (BaseSteel as per IS 513, D quality, galvanized as per IS 277 with Zinc of
120 GSM). The factory made section should be powder coated with Pure polyester powder
upto 50-60 microns thick with total coated thickness of 0.8 mm for Outer Frame and
0.58mm thickness for Sliding Shutter Section. The Outer Frame size for Two Tracks with
Grill provision is 90mm x 50mm and without grill provision is of 75mm x 50 mm. The
Window Shutter section is of 58 mm x 36 mm. The Outer Frame should have Two
integrated Guide tracks of 12mm width and 24mm deep for provision to slide the Shutter /
sash frame and facilitates with a water drain outlet component made of PVC. The Shutter
frame should be fitted with 5mm thick plain float glass of reputed make and fixed with
EPDM weathering seal resistant accessories and handle made of Alumimium 1 No. per each
shutter. The sections are to be cut to length miter joined with corner brackets. The total
window system is to be installed at the site using anchor fasteners, Silicon sealant applied at
the Outer Frame Corners. The cost is inclusive of conveyance of all materials accessories,
labour charges, and erection at site with complete finished item of work.
Page No. 304
38.34.1 Window with Two Sliding Shutters and with Grill Outer Frame Size 90 mm x 50 mm have
a rebate of 15mm x 5 mm to fit grill made of 10mm MS Sq Rods for horizontal bars welded Sqm 5784.00
at a regular pitch of 150mm to 12mm x 6 mm MS flat.
38.35 SLIDING WINDOWS (3 shutters) or equivalent sliding Windows (suitable for residential
and non-residential buildings):Providing and fixing of Sliding Windows made of Galvanized
Steel (Base Steel as per IS 513, D quality, galvanized as per IS 277 with Zinc of 120 GSM).
The factory made section should be powder coated with pure polyester powder upto 50-60
microns thick with total coated thickness of 0.8 mm for Outer Frame and 0.58mm thickness
for Sliding Shutter Section. The Outer Frame size for Two Tracks with Grill provision is
135mm x 50mm. The Window Shutter section is of 58 mm x 36 mm. The Outer Frame
should have Two integrated Guide tracks of 12mm width and 24mm deep for provision to
slide the Shutter / sash frame and facilitates with a water drain outlet component made of
PVC. The Shutter frame should be fitted with 5mm thick plain float glass of reputed make
and fixed with EPDM weathering seal resistant accessories and handle made of Alumimium
1 No. per each shutter. The sections are to be cut to length miter joined with corner brackets.
The total window system is to be installed at the site using anchor fasteners, Silicon sealant
applied at the Outer Frame Corners. The cost is inclusive of conveyance of all materials
accessories, labour charges, and erection at site with complete finished item of work

38.35.1 i) Center Shutter Fixed: center shutter frame made of section with size 36mm x 58mm
should be fitted with 5mm thick plain float glass of reputed make, EPDM gasket all around
the glass and fixed to the Outer Frame with the supporting section of size 29mm x 20mm of Sqm 6383.00
0.58mm thick fixed horizontally on top and bottom of the shutter frame

38.35.2 ii) Center Shutter Sliding: center shutter frame made of section of size36mm x 58mm
should be fitted with 5 mm thick plain float glass of reputed make. The supporting guide
section of size 15mm x 19mm of 0.58mm thick fixed horizontally at top and bottom of Sqm 6461.00
shutter frame and slides along the bottom and top guide tracks made of sections size 24mm x
20mm of 0.58mm thick and 29mm x 20mm of 0.58mm thick.

Page 221 of 350


38.36 Steel Windows with grill and flymesh for residential buildings vProviding and fixing of
windows made of pre-painted steel (base steelas per IS 513 of 0.58mm tick galvanized as per
IS 277 with zinc of 120GSM). Primer coated with epoxy primer of 5-7 microns thick,
finishpainted with a polyester paint of 12-16 microns thick and back coatedwith 5-7microns
thick alkyd backer. Section for outer frame should beof 72x55mm, centre mullion should be
of 72x50mm, section of the fixed glass beading should be of 12x12mm. and section of the
shutter shouldbe of 48x25mm. Outer frame and mullion sections to have rebate forglazed
shutters, fly mesh and 20mm provision for guard bars/grill flymesh shutters section should
be of 20x40mm. The sections are to becut to length mitre joined with corner bracket. Centre
mullion is to befixed with mullion cap. Handle latch 2 Nos of heavy duty stainless steelpivot
hinges shall be provided for shutter. The window should be ledwith 50mm thick plain float
glass and S.S. Mesh for fly mesh shutter(304 grade). Rubber gaskets are to be provided all
around the glass. The above frames should be fixed to the concrete/masonry wall bymeans of
self-expanding screws, including 10mm square guard barswith 6” (152.4mm) pitch complete
for finished item of work.

Page No. 305


38.36.1 Double shutter window with vertical mullion 3’0”x4’0” (914.4mm x1219.2mm) outer
frame section size of 72x50mm shutter frame section size of 48x25mm mullion section size Sqm 7272.00
of 72x50mm.
38.36.2 Centre fixed both side openable shutter window 5’0”x4’0” (1524mm x 1219.2mm). Outer
frame section size of 72x50mm. Shutter frame section size of 48x25mm mullion section size Sqm 7023.00
of 72x50mm. Fixed beading section size of 12x12mm
38.37 Steel Windows with grill for residential buildings Providing and fixing of windows made of
pre-painted steel (base steel as per IS 513 of 0.58mm tick galvanized as per IS 277 with zinc
of 120GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a
polyester paint of 12-16 microns thick and back coated with 5-7microns thick alkyd backer.
Section for outer frame should be of 48x50mm, centre mullion should be of 48x50mm,
section for shutter should be of 48x25mm and fixed glass beading section should be of
12x12mm. Outer frame and mullions to have rebate for glazed shutter and a 20mm provision
for guard bars/grills. The sections are to be cut to length mitre joined with corner bracket.
Centre mullion is to be fixed with mullion cap. Handle stay 2Nos of stainless steel heavy
duty pivot hinges shall be provided for shutter. The window should be panelled with 5mm
thick plain float glass. Rubber gaskets are to be provided all around the glass. The above
frames should be fixed to the concrete/ masonry wall by means of self expanding screws,
including 10mm square guard bars with 6” (152.4mm) pitch etc., complete for finished item
of work.

38.37.1 Double shutter window with vertical mullion 3’0”x4’0” (914.4mm x1219.2mm) outer
frame section size of 48x50mm shutter frame section size of 48x25mm mullion section size Sqm 4210.00
of 48x50mm.
38.37.2 Centre fixed both side openable shutter window 6’0”x4’0” (1828.8mmx1219.2mm).
Outer frame section size of 48x50mm shutter frame section size of 48x25mm mullion Sqm 4595.00
section size of 48x50mm. Fixed beading section size of 12x12mm.
Page No. 306
38.38 Pre-painted steel windows / ventilators & door frames: Supply and fixing of windows
and top hung and fixed louered ventilatorsmade of pre-painted steel (base steel as per IS 513
of -0.58mm thick‘D’ quality, galvanized as per IS 277 with zinc of 120 GSM) with
apolyester paint, of 12-16 microns thick and back coated with 5-7 micronsthick alkyd
backer. Section for outer frame should be 46x52mm, sectionfor shutter should be 46x46mm,
section for mullion should be 46x70mm,and section for beading should be 18x25mm and
section for louvered ventilator should be 33x57mm the windows hould be pannaled with 5
mm thick plain float glass and 4mm pinhead glass for ventilators with rubber Gasket. The
sections are to be cut to length, mitre joined with corner bracket and centre mullions are to
be fixed using mullion cap. Handle made of high grade aluminium powder coated and nylon
receiver. Corner brackets made of CRCA with Zinc Phosphate. Mullion caps made of glass
filled nylon. The above frames should be ixed to the concrete/ masonry will by means of
self-expanding screws. Including 10mm square bars with 6” pitch complete finished item of
work.

38.38.1 WINDOWS : Double shutter 3’-0” X 4’ - 0” (914.4MM x 1219.2 MM) outer frame section
Sqm 4304.00
size of 46x52mm shutter frame section size of 46x46mm.

Page 222 of 350


38.38.2 WINDOWS : Centre fixed both side openable shutter 5’-0” x 4’-0” (1524x1219.2mm)
outer frame section size of 46x52mm shutter frame section size of 46x48mm mullion section Sqm 4028.00
size of 46x70mm fixed beading section size of 18x25mm.
38.38.3 Ventilators : Top hung 4’-0” x 3’-0” (1219.2x914.4mm) outer frame section size of
Sqm 4050.00
46x52mm shutter frame section size of 46x46mm mullion section size of 46x70mm.
38.38.4 Ventilators : Fixed lovers 4’-0” x 3’-0” (1219.2x914.4mm) (Box section) outer frame
Sqm 3900.00
section size of 33x57mm mullion section.
38.39 Road Humps / speed breakers for control of vehicular speeds on roads Providing road
humps for the entire formation width, using bituminous premix materials and heavy duty
cobble stones 60 mm thick, having road hump dimension of 1.00 mtr. (width) X 0.15 mtr
(height) rectangular sections and ramp on either side of road hump of 0.85 mtr (wide),
including providing WBM (2 layers) for shoulder portion 1.7mts in length on either side,
completing with road marking paint with applied thermoplastic compound with reflecting
glass beeds on bituminous surface and providing 2 Nos. retro reflective traffic signs as per
IRC SP 67 -2010 (for details refer IRC 99-1988)

38.39.1 For single lane for formation width of 7.50mtrs. and using SDBC mix meterial. Unit 27877.00
38.39.2 For Intermediate lane for formation width of 9.00mtrs using SDBC mix
Unit 32600.00
material.
38.39.3 For 2 lane for formation width of 12mtrs. using SDBC mix material. Unit 41797.00
Page No. 307
38.40 Providing road humps for the entire formation width, using bituminous premix materials
and heavy duty cobble stones 60 mm thick, having road hump dimension of 1.00 mtr.
(width) X 0.15 mtr (height) rectangular sections and ramp on either side of road hump of
0.85 mtr (wide), including providing WBM (2 layers) for shoulder portion 1.7mts in length
on either side, completing with road marking paint with applied thermoplastic compound
with reflecting glass beeds on bituminous surface and providing 2 Nos. retro reflective
traffic signs as per IRC SP 67 -2010 (for details refer IRC 99-1988)

38.40.1 For single lane for formation width of 7.50mtrs. and using BC mix
Unit 30283.00
meterial.
38.40.2 Intermediate lane for formation width of 9.00mtrs using BC mix material. Unit 33566.00
38.40.3 2 lane for formation width of 12mtrs. using BC mix material. Unit 43083.00
38.41 Providing, laying, rumble strips, 250 mm wide and 25mm height in rectangular shape at
1.00 mtr center to center for the entire formation width of road using pre mix bituminous
material, including providing WBM (2 layers) for shoulder portions, applying tack coat,
providing 2 Nos. retro reflective traffic signs as per IRC SP 67-2010 (for details IRC 99-
1988)
38.41.1 For 3 nos - including Wbm layers for length of 2 mtrs on either side of carriage way in
shouldr portion.
38.41.1. Single lane using SDBC mix material
Unit 15257.00
1
38.41.1. Intermediate lane using SDBC mix material.
Unit 14917.00
2
38.41.1. 2 lane using SDBC mix material.
Unit 18443.00
3
38.41.2 For 5 nos - including Wbm layers for length of 4 mtrs on either side of carriage way in
shouldr portion.
38.41.2. Single lane using SDBC mix material
Unit 21124.00
1
38.41.2. Intermediate lane using SDBC mix material.
Unit 20535.00
2
38.41.2. 2 lane using SDBC mix material.
Unit 26385.00
3
38.41.3 For 10 nos - including Wbm layers for length of 9mtrs on either side of carriage way in
shouldr portion.
38.41.3. Single lane using SDBC mix material
Unit 35723.00
1
38.41.3. Intermediate lane using SDBC mix material.
Unit 34543.00
2

Page 223 of 350


38.41.3. 2 lane using SDBC mix material.
Unit 46243.00
3
38.41.4 For 15 nos - including Wbm layers for length of 15 mtrs on either side of carriage way in
shouldr portion.
38.41.4. Single lane using SDBC mix material
Unit 50301.00
1
38.41.4. Intermediate lane using SDBC mix material.
Unit 48524.00
2
38.41.4. 2 lane using SDBC mix material.
Unit 66072.00
3
38.42 Providing and laying Geocells ultrasonically welded 1.30mm thick, HDPE strips,
expandable to form GEOCELLS of honeycomb structure, anchoring to metal pegs at each
and cell to be laid on prepared surface.
38.42.1 - do - 100mm height Sqm 370.00
38.42.2 - do - 150mm height Sqm 480.00
Page No. 308
38.43 Providing, fabricating and fixing profiled poly erethane insulated roof of 1,06m width and
7,60m length sheets roof having external sheet of 0.5mm steel with powder coated finish,
bottom sheet of 0.4mm steel with powder coated finish. The roofing system shall have water
proof over lapping arrangement at the inter section of two sheets the fasting shall be of self Sqm 2250.00
tapping screws dia 6.3mm or required length with PVC head along with washer pre-painted
aluminium cap unit with build in seal arrangements. The entire roof shall be firmly fasteed to
the existing frame

38.44 uPvC Windows and Doors


38.44.1 Providing & fixing of glazed 2 Track-2 Panel Sliding Windows made out of multi Chamered
uPVC sections with TPV gaskets having Isolated drainage and reinforced witgh Galvanized
iron profiles through out the window. The outer frame having a overall size of 60x45 mm
with reinforcement of 1 mm thickness and sash with overall size of 39x58 mm with
reinforcement of 1.5mm thickness. Glazing bead for fixing ofglass shall be of size 20x18mm
and coextruded with gasket. Windows shall be provided with 5mm plain float glass, standard
hardware & single point locking system of flush lock, Wall thickness of frame & sash shall Sqm 6400.00
be 2-2.2 mm. (P.No. 301/ I. No. 38.44.1 of CSR 2015-16

38.44.2 Providing & fixing of glazed Openable Window made out of multi chambered uPVC
sections with TPV gaskets having isolated drainage and reinforced with Galvanixed iron
profiles throuhout the window. The outer frame having a overall size of 60x55 mm with
reinforcement of 1 mm thickness, mullion with overall size of 74x60 mm with reinforcement
of 1 mm and sash with overall size of 75x60 mm with reinforcement of 1.5 mm thickness.
Sqm 7000.00
Glazing bead for fixing of glass shall be of size 34x20 mm and coextruded with gasket.
Windows shall be provided with 5mm plain float glass, standard hardware & single point
locking system of flush lock, Wall thickness of frame, mullion & sash shall be 2-2.2 mm.

38.44.3 Providing & of Fixed Louvered Ventilator made out of multi chambered uPVC sections with
TPv gaskets having isolated drainage and reinforced with Galvanized Iron profiles through
out the windown. The outer frame having a overall size of 60x55mm with reinforcement of 1
mm thickness and Mullion with overall size of 74x60mm with reinforcement of 1 mm Sqm 6200.00
thickness. Ventilator shall be provided with 4.5 mm Pin Head glass, standard hardware, Wall
thickness of frame Mullion shall be 2-2.2 mm.

Page 224 of 350


38.44.4 Providing & fixing of Top hung Ventilator With Exhaust Fan Provision made out of multi
chambered uPVC sections with TPV gaskets having isolated drainage and reinforced with
Galvanized Iron profiles through out the Windown. the outer frame having a overall size of
60x55 mm with reinforcement of 1 mm thickness, Mullion with overall size of 74x60 mm
with reinforcement of 1 mm thickness and Sash with overall size of 75x60 mm with
Sqm 7000.00
reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be of size 34x20
mml coextruded with gasket, Ventilator shall be provided with 4.5 mm Pin Head glass,
standard hardware, single point locking and friction stays,. Wall thickness of frame, mullion
& sash shall be 2-2.2 mm.

38.44.5 Providing & fixing of glazed 3 Track - 2 Panel Sliding Windown With Mesh made out of
multi chambered uPVC sections with TPv gaskets having isolated drainage and reinforced
with GI throughtout the window. the sliding outer frame having a overall size of 108x45 mm
with reinforcement of 1 mm thickness, sash with overall size of 39x58 mm with
reinforcement of 1.5 mm thickness, mesh sash of overall size 30x48.5 mm reinforced with
1.5 mm of GI. Glazing bead for fixing kof glass shall be of size 20x18mm and coextruded Sqm 7500.00
with gasket. Fiber Glass mesh shall be provided in mesh shutter. Windows shall be provided
with 5 mm plain float glass, standard hardware and single point locking system of flush lock.
Wall thickness of frame, mullion & sash shall be 2-2.2 mm.

Page No. 309


38.44.6 Providing & fixing of glazed 3 Track - 2 Panel Sliding Door made out of multi chambered
uPVC sections with TPV gaskets having isolated drainage and reinforced with Galvanized
Iron profiles through out the window. The sliding outer frame having a overall size of 60x45
mm with reinforcement of 1 mm thickness, super sas with overall size of 39x75 mm with
reinforcement of 1.5mm thickness. Glazing bead for fixing of glass shall be of size 20x18
mm and coestruded with gasket. Fiber Glass mesh shall be provided in mesh shutter. Sqm 6000.00
Window/Door shall be provided with 6 mm plain float glass, stgandard hardware & multi
point locking system of patio espagnolette. Wall thickness of frame, mullion
& sash shall be 2-2.2 mm.

38.44.7 Providing & fixing of glazed 3 Track - 2 Panel Sliding Door With Mesh … made out of
multi chambered uPVC sections with TPV gaskets having isolated drainage and reinforced
with Galvanized Iron profiles through out the window. The sliding outer frame having a
overall size of 108x45 mm with reinforcement of 1 mm thickness, super sash with overall
size of 39x75 mm with reinforcement of 1.5 mm thickness, mesh sash of overall size
30x48.5 mm reinforced with 1.5 mm of GI.Glazing bead for fixing of glas shall be of size Sqm 7000.00
20x18mm and coextruded with gasket. Fiber Glass mesh shall be provided in mesh shutter.
Window/Door shall be provided with 6 mm plain float glass, standard hardware & multi
point locking system of Patio espagnolette. Wall thickness of frame, mullion & sash shall be
2-2.2 mm.

Page 225 of 350


38.45 Consultancy services for Preparation of Land Plan Survey for state Highways and major
District roads The entire Land Survey Plan should be carried out using
LiDAR Technology only, Collection of all the relevant information for 50 Mtr on either side
from

The entire Land Survey Plan should be carried out using LiDAR Technology only,
Collection of all the relevant information for 50 Mtr on either side from centre of the road,
Details of Structures (if any), Cross Drainage Structures, Arboriculture counts and other
Assets, which have been developed as a part of the road furniture / development.
Establishing the Primary Control Points (Horizontal Control), using the DGPS at every
1000 meters interval and secondary control points at every 500 meters and also at important
and salient locations, such as major inter sections, Village / Town limits etc.,. The DGPS
controls will be so established that it meets the minimum criteria specified for carrying out
the mapping activities on a scale of 1:5000 or 1:10000. (Inclusive of all taxes) NOTES: (a)
The DGPS control points established will be further extended using the total station for
densification so that there are Control Points for every 200 m interval at staggered locations.
All Physical details shall be picked up for a width of 50M from the center line on either side
of the road. Primary control points shall be a properly monumented using Cement Concrete KM 36000.00
Pillar (RCC) of size 230 mm x 230 mm x 1250 mm, out of which 550 mm is embedded in
Cement Concrete below the ground level. All such Pillars shall be serially numbered and
painted in two coats of Golden Yellow Colour. The X, Y, Z co-ordinates shall be referred to
center of the Pillar marked on top of it. The co-ordinates shall be painted in red color. A list
of all Primary and Secondary control points with X,Y,Z Co-ordinate should be submitted.
Original Revenue Village Survey Maps will be collected from revenue authorities and all
the Control Points shall be physically verified and marked on top of it. (a. RTC and other
information required shall be collected by the Consultants from the appropriate authorities,
b. Within RoW, if there are any encroachments, then the consultant shall get relevant records
and prepare the relevant documents for transferring RTC in the name of PWD.) Cadastral
(Revenue) Survey will be carried out in order to demarcate the Right of Way of the road and
also of all the encroachments. A statement shall be prepared showing the extent of Right of
Way, Encroachment, including other assets, Survey Number wise in standard format as
approved by PRAMC. The process carried out should be accurate enough to issue the
necessary notices to the encroachers for getting them cleared.
The following documents in both Hard and Soft Copy (where required) should be furnished :
1. 1:4000 Drawings which includes, Details of SH, shall
cause to be marked on the map, thereon, Highway boundaries and Buildings and Controll
38.46 Providing and fixing self-supported, ribbed, high quality, high grade (D:350 MPA Yst Min ),
Lines and other particulars. such as RoW, Road Boundaries, DGPS Points, Existing
pre- painted Galvalume steel roof sheet, coated with bare Galvalume coating AZ 150, @ 150
Inventories, Survey Numbers, Control Points, Alignment Details etc
gms/Smtr 55%AL,45%Zn) by hot dip process , of total coated thickness as specified for
2. All required data sheets
different spans with a tolerance of +/- 0.02 mm, according to technical specification
3. Point Cloud Data of Area of Interes
confirming to A 792, with NCCA ll-1, or ECCA T4 Pencil hardness HB, NCCA standard T-
4. Drawing File containing 3D information of required details
Bend test. The roof should be fastened to the gutter beam, on the external sloping side, at an
5. Images Captured along with Video files using LiDAR
interval of 51mm Centre to Centre, to a depth of 65 mm with GI anchor bolts and neoprene
6. Superimposed Alignment on the State Map supplied by the client, duly indicating the
washers & subjecting the gutter beam to Schmidt, Hammer test to ensure the anchorage of
Survey Numbers and other details such as encroachments
the anchor bolts. The self-supported roofing system should be designed to with stand the
7. RTC Copies collected from Revenue Authorities and RTC Transferred accordingly
wind load (As per IS 875 part-3) & Earthquake load (as per IS 1893) & the design should
8. Khatha Certificate from respective authorities for the entire stretch of land registered in
also comply with any other technical requirements such as turbo ventilators of 0.60 mts. dia
the name of the Executive Engineer of the respective Divisions.”
and skylights of size 4.26 x 0.60 mts. fixed one in each row @ 10.00 Mtr C/C along the
9. List of land encroached along with extent of land and name of the encroacher with all
length & hangers for electrical fixtures as per the requirements including cost of all materials
details as per standard format.
&labour for erection, all lead and lift, loading and unloading, HOM of machineries etc.,
10. All Documents shall be submitted in colour and with proper binding along with soft
complete as per the standard detailed technical specification, design and directions of the
copies – 5 Nos. each.
engineer in charge of the work.
11. The formats for Data Collection and reports, layerisation of drawings indicating the
factors in standard prescribe colour and Page No. shall
symbals, 310 be approved by PRAMC (Note: The
38.46.1 soft copies to be made compatible to be uploaded in the PWD web site- www. kpwd.gov.in)
(a) Span : 9 Meters upto 15 Meters (b) Material Specification: Colour Coated Galvalume
12. Inweighing
areas, where sqm 1750.00
Sheet, 10.10cities/urban
kg/sqm BMT:development
0.80 MM,isAPT
encountered,
: 0.85 MM,mapping shall
tolerance +/- be carried out
0.02mm
on 1:2000 Scale, whereas, in cross country it can be on 1:4000 scale.”
38.46.2 a) Span :Above 15 Meters upto 18 Meters (b) Material Specification: Colour Coated
Galvalume Sheet, weighing 11.35 g/sqm BMT: 0.90 MM, APT : 0.95 MM, tolerance +/- sqm 1850.00
0.02mm
38.46.3 (a) Span : Above 18 Meters upto 21 Meters (b) Material Specification: Colour Coated
Galvalume Sheet weighing 12.57kg/sqm BMT: 1.00 MM, APT : 1.05 MM, tolerance +/- Sqm 1950.00
0.02mm
38.46.4 (a) Span : Above 21 Meters upto 23 Meters (b) Material Specification: Colour Coated
Galvalume Sheet weighing 13.80kg/sqm BMT: 1.10 MM, APT : 1.15 MM, tolerance +/- Sqm 2100.00
0.02mm

Page 226 of 350


38.46.5 (a) Span : Above 23 Meters upto 25 Meters (b) Material Specification: Colour Coated
Galvalume Sheet, weighing 15.16kg/sqm BMT: 1.20 MM, APT : 1.25 MM, tolerance +/- Sqm 2200.00
0.02mm
38.46.6 (a) Span : Above 25 Meters upto 27 Meters (b) Material Specification: Colour Coated
Imported Galvalume Sheet, weighing 16.40 kg/sqm BMT: 1.30 MM, APT : 1.37 MM, Sqm 2300.00
tolerance +/- 0.02mm
38.46.7 (a) Span :Above 27 Meters upto 30 Meters (b) Material Specification: Colour Coated
Imported Galvalume Sheet, weighing 17.63 kg/sqm BMT: 1.40 MM, APT : 1.47 MM, Sqm 2450.00
tolerance +/- 0.02mm
Page No. 311
38.46.8 (a) Span :Above 30 Meters upto 32 Meters (b) Material Specification: Colour Coated
Imported Galvalume Sheet, weighing 18.87 kg/sqm BMT: 1.50 MM, APT : 1.57 MM, sqm 2600.00
tolerance +/- 0.02mm
38.46.9 (a) Span : Above 32 Meters upto 35 Meters (b) Material Specification: Colour Coated
Imported Galvalume Sheet, weighing 20.10kg/sqm BMT: 1.60 MM, APT : 1.67 MM, sqm 2700.00
tolerance +/- 0.02mm
38.47 Providing and applying a heat reflecting anti-fungal water based, flexible, water proofing,
roof coating for use on Roof/Terrace/Parapet. by formulating the undercoat with polymer
modified cementations water proof slurry mortar and top coat consisting of 100% Acrylic
Elastometric Ploymers embedded with heat reflecting particles. For surfaces having cracks
less than 5mm.
38.47.1 do: - in high rainfall areas(Two layers of under coat plus two layers of top coat) sqm 550.00
38.47.2 do: - in low rainfall areas(One layers of under coat plus two layers of top coat) sqm 500.00
38.48 Construction of embankment / sub grade using nanotechnology based chemical
stabilizer and Cement.
38.48.1
Construction of embankment using nanotechnology material. Construction of
embankment with approved material gravel/murrum and chemical stabilized like
nanotechnology based organosilane or equivalent (confirming to the required spec.) mixed
in water @0.5kg/ cum (for soil CBR above 5%) and 1% cement by weight of soil, with all cum 887.00
lifts and leads, transporting to site, spreading, grading to required slope and compacting to
meet requirement table 300-2 complete as per specifications. (Which includes cost of
gravel/murrum, watering charges & compacting by vibratory roller) MORTH Specification
No. 305
38.48.2 Construction of embankment with material deposited from roadway cutting using
nanotechnology material. Construction of Embankment with approved material deposited
at site from roadway cutting and excavation from drain and foundation of other structures
graded and chemical stabilizer like nanotechnology based organolilane or equivalent
cum 740.00
(confirming to the required spec.) Mixed in water @ 0.5kg/ cum and 1% cement by weight
of soil and compacted to meet requirement of table 300-2 complete as per specifications.
(Which includes, watering charges & compacting by vibratory roller) MORTH Specification
No. 305
38.48.3
Construction of subgrade and earthen shoulders using nanotechnology material:
Construction of sub-grade and earthen shoulders with approved material gravel/murrum and
chemical stabilizer like nanotechnology based organosilane or equivalent (confirming to the
required spec.) Mixed in water @ 0.5kg/cum (for soil CBR above 5%) and 1% cement by cum 890.00
weight of soil with all lifts & leads, transporting to site, spreading, grading to required slope
and compacted to meet requirement of table no. 300-2 complete as per specifications
(Including cost of earth, watering charges & compaction by vibratory roller) MORTH
Specification No. 305
Page No. 312
38.48.4 Loosening of the ground upto a level of 500mm below the subgrade level, watered, graded
and compacted in layers to meet requirement of table 300-2 for subgrade construction
complete as per specifications. Case-I : Compacting original ground supporting subgrade
using chemical stabilizer like nanotechnology based organosilane or equivalent (confirming cum 708.00
to the required spec.) mixed in water @ 0.5kg/cum and 1% cement by weight of soil, (which
includes water charges & compaction by vibratory roller). MORTH Specification No.
305.3.4

Page 227 of 350


38.48.5 Loosening, levelling and compacting original ground supporting embankment to facilitate
placement of first layer of embankment, scarified to a depth of 150mm, mixed with water at
OMC and then compacted by rolling so as to achieve minimum dry density as given in table
300-2 for embankment construction. Compete as per specifications. Case – II : Compacting
original ground supporting embankment using chemical stabilizer like nanotechnology based
cum 685.00
organosilane or equivalent (confirming to the required spec.) mixed in water @0.5kg/cum
and 1% cement by weight of soil (which includes watering charges & compaction by
vibratory roller) MORTH Specification No. 305.3.4

38.49 METALIC DOOR FRAMES


38.49.1
Door Frame - Entrance : Providing & fixing factory made Galvanized plain steel door
frame of profile size 125 x 60 mm single rebate manufactured from galvanized plain steel
sheet 1.25 mm thick, conforming to IS:277. The door frame consists of hinge jamb, lock
jamb, head & bottom tie bars, supply in knockdown condition & to be assembled at site by
mechanical means with special mitre joint. The bottom tie bar made out of galvanized plain
steel sheet 1.60 mm thick pressed angle 20 x 20 mm screwed to the door frame. The
stiffeners of 3 mm thick pre- punched & pre-trapped are to be welded inside the pre-punched
rmt 610.00
slots of the door frames & 4 nos. of S.S. butt hinges 100 x 59 x 2.5 mm to be screwed to the
door frame. The necessary stiffeners & mortar guards to be provided for fixing hardware
fixtures. The door frame to be powder coated after pre- treatment of the surface. The door
frame shall be filled with 1:3:6 cement concrete & to be fixed with adjustable lugs/ hold
fasts. Alternatively, dry fixing shall be permitted by using metallic expansion bolt. The rate
is including transportation, loading, unloading, HOM etc. but excluding the hardware
fixtures. size 1000 x 2130 mm

38.49.2
Door Frame - Internal: Providing & fixing factory made Galvanized plain steel door frame
of profile size 125 x 60 mm single rebate manufactured from galvanized plain steel sheet
1.25 mm thick, conforming to IS: 277. The door frame consists of hinge jamb, lock jamb,
head & bottom tie bars, supply in knockdown condition & to be assembled on site by
mechanical means with the special miter joint. The bottom tie bar made out of galvanized
plain steel sheet 1.60 mm thick pressed angle 20 x 20 mm to be screwed to the door frame.
The 4 nos. of G.I. Lift off hinge 100 x 67 x 2 mm to be projected welded to the door frame. rmt 480.00
The necessary stiffeners & mortar guards to be provided for fixing hardware fixtures. The
door frame to be powder coated after pre-treatment of the surface. The door frame shall be
filled with 1:3:6 cement concrete & to be fixed with adjustable lugs/ hold fasts.
Alternatively, dry fixing shall be permitted by using metallic expansion bolt. The rate is
including transportation, loading, unloading, HOM etc. but excluding the hardware fixtures.
size 900 x 2130 mm

Page No. 313


38.49.3
Door Frame – Wet areas – W.C. / bath: Providing & fixing factory made Aluminium Zinc
coated steel door frame of profile size 105 x 60 mm single rebate manufactured from
Aluminium Zinc metallic coated steel sheet 1.20 mm thick, conforming to IS: 15961. The
door frame consists of hinge jamb, lock jamb, head & bottom tie bars & supply in
knockdown condition & to be assembled on site by mechanical means with special mitre
joint to be bottom tie bar made out of galvanized plain steel sheet 1.60 mm thick pressed
angle 20 x 20 mm to be screwed to the door frame. The 3 nos. of S.S. butt hinges 100 x 58 x rmt 535.00
1.9 mm to be projection welded to the door frame. The necessary stiffeners & mortar guards
to be provided for fixing hardware fixtures. The door frame to be powder coated after pre-
treatment of the surface. The door frame shall be filled with 1:3:6 cement concrete & to be
fixed with adjustable lugs/ hold fasts. Alternatively dry fixing shall be permitted by using
metallic expansion bolt. The rate is including transportation, loading, unloading, HOM etc.
but excluding the hardware fixtures. size 750 x 2130 mm

38.49.4 Door Frame – Wet areas – W.C. / Bath: Do- with Profile Size 90 x 50 mm - size 750 x
rmt 495.00
2130 mm
39.50 METALIC DOOR SHUTTERS

Page 228 of 350


38.50.1
Door Shutters Entrance : Providing & fixing factory made Galvanized steel door Shutters
32 mm thick manufactured from pre- painted Galvanized plain steel sheet 0.60 mm thick
conforming to the IS: 14246. The door shutters consist of two outer skins if steel sheets, lock
seam jointed at vertical stile edges, horizontal top & bottom sides to form a double skin fully
flush shell. Rigid polyurethane Foam (PUF) of density 40 Kg/M3 shall be filled in the sqm 2400.00
hollow portion of door shutters for structure rigidly & sound insulation. The necessary
stiffeners of the Galvanized plain steel sheet of minimum thickness 1.60 mm to be provided
for fixing all hardware fixtures. The rate is including transportation, loading, unloading,
HOM etc. but excluding the hardware fixtures. size – 900 x 2035 x 32 mm thick.

38.50.2 Door shutters - internal - Do - of Size – 800 x 2035 x 32 mm thick. sqm 2500.00
38.50.3
Door shutters - Wet areas – W.C. / bath : Providing & fixing factory made Galvanized
steel door Shutters 32 mm thick manufactured from pre- painted Aluminium-zinc metallic
coated steel sheet 0.60 mm thick conforming to the IS: 15961. The door shutters consist of
two outer skins of steel sheets, lock seam jointed at vertical stile edges, horizontal top &
bottom sides to form a double skin fully flush shell. Rigid polyurethane Foam (PUF) of
sqm 2800.00
density 40 Kg/M3 shall be filled in the hollow portion of door shutters for structure rigidly
& sound insulation. The necessary stiffeners of Galvanized plain steel sheet of minimum
thickness 1.60 mm to be provided for all hardware fixtures. The rate is including
transportation, loading, unloading, HOM etc. but excluding the hardware fixtures. size – 650
x 2035 x 32 mm thick.

38.50.4
Door shutters - Wet areas – W.C. / bath : Providing & fixing factory made Galvanized
steel door Shutters 32 mm thick manufactured from pre- painted Aluminium-zinc metallic
coated steel sheet 0.60 mm thick conforming to the IS: 15961. The door shutters consists of
two outer skins of steel sheets, lock seam jointed at vertical stile edges, horizontal top &
bottom sides to form a double skin fully flush shell. Rigid polyurethane Foam (PUF) of
sqm 2750.00
density 40 Kg/M3 shall be filled in the hollow portion of door shutters for structure rigidly
& sound insulation. The necessary stiffeners of Galvanized plain steel sheet of minimum
thickness 1.60 mm to be provided for all hardware fixtures. The rate is including
transportation, loading, unloading, HOM etc. but excluding the hardware fixtures. size – 670
x 2045 x 32 mm thick.

Page No. 314


38.51 Providing and laying – Pervious concrete of grade M15 as per specification using paver
and roller where ever necessary complete. This includes the cost of all material, Labour,
HOM of machinery, Laying, Compacting, Curing etc. as per the instruction of Engineer in cum 5500.00
charge of the work.
38.52 Providing Stainless steel reinforcement (Duplex Grade - 532101) for RCC work
including straightening, cutting, bending, hooking, placing in position, lapping
and / or welding wherever required, tying with binding wire and anchoring
to the adjoining members wherever necessary complete as per design Tonne 210272.00
(laps, hooks and wastage shall not be measured and paid) cost of
materials, labour, HOM of machinery complete as per specifications.

38.53 Providing and mixing Alkali resistant integral glass fibers HD 67/36 to act as a replacement
of steel reinforcement in supported slabs and to provide secondary reinforcement in concrete
at 5 kg / cum of concrete, fibers of length 36 mm, diameter 19 microns,specific gravity 2.68,
modulus of elasticity 72 Gpa and having the aspect ratio (length/dia) of 67, including cost of
labour,materials and HOM of machineries etc cum 3480.00
complete.(Note:The work to be carried out with prior permission of the competent
authourity.) ( NOTE: Rate is for cum of concrete)

38.54
38.55
38.56
38.57
38.58
38.59
38.60

Page 229 of 350


38.61
38.62
38.63
38.64
38.65
38.66
38.67
38.68
Page No.319

39.0 39.FURNISHING WORK

39.1 Providing and fixing veneer paneling over the 50mm x 35mm sal wood frame work and top
covered out of 4mm thick approved veneer fixed over 12mm ply finished in mealamme
polish, complete including cost and conveyance of all materials, labour for all items of work
HOM of equipment etc., complete as per specification. (P.No.311, I.No. 39.1 of PWD SR Sqm 4700.00
2015-16)

39.2 Providing and fixing acoustic Veneer paneling, over the 50mm x 35mm sal wood frame
work at spacing not exceeding 600mm c/c fixed to the wall and top covered out of 4mm
thick approved quality Veneer, fixed over 19mm thick ply strips of 100mm to 200mm with a
gap of 6 to10mm in between strips of approved brand termite and water resistance, finished Sqm 4900.00
with melamine polish, complete including cost and conveyance of all materials, labour for
all items of work, HOM of equipment complete as per specification.

39.3 Manufacturing, supplying and fixing wooden ward robe of 0.60m deep using 19mm thick
vinyl bonded water proof block board, shutters allround ward robe, lockable drawers with
sliding channels, cupboard drapery hangers, curtain rods with end brackets, openable
shutters with 19mm x 6mm thick plain teak wood beading, lipping 1.5mm thick commercial
ply vertical support finished in approved 1.5mm lamination sheet of approved colour, shade
and quality on all exposed surfaces. Inner surface painted with 2 coats of white synthetic
enamel paint over 2 coats of Patti, one coat of wood primer, including cost of brass fittings, Sqm 12500.00
parliamentary hinges, C handles, tower bolts, magnetic catches, approved brand lock,
adhesives, synthetic resins, nails, screws etc., complete including cost of all materials, labour
charges, complete as per specification. (P.No.311, I.No. 39.3 of PWD SR 2015-16)

39.4 Providing and fixing storage unit of 0.75m width made out of 19mm thick commercial ply
vertical support finished in approved 1.5mm laminate with 12mm thick ply packing
internally finished with enamel paint of approved colour and shade shelves shall be formed
out of 19mm ply finished with enamel paint of approved shade and colour and 19mm thick Sqm 10800.00
shutters formed out of 19mm thick ply finished with 1.5mm thick laminate of approved
shade and colour etc., complete the rate includes cost of all materials, labour charges,
complete as per specification.(P.No. 311, I.No. 39.4 of SR 2015-16)

39.5 Providing and fixing Single shutter glass door of 12mm thick plain toughened glass (Saint
Gobain, Modi float). The door is fixed by using any approved make hardware fitting like
patch fitting, pivot, floor machine, locking arrangements and suitable SS door rails with
floral glass etching for 1/3 portion of door area etc complete. The rate includes cost of all Sqm 11400.00
materials, labour, hire of tools & machineries,and as per specification.

39.6 Providing and fixing Double shutter glass door of 12mm thick plain toughened glass of
approved make (Saint Gobain, Modi float). The door is fixed by using any approved make
hardware fitting like patch fitting, pivot, floor machine, locking arrangements and suitable
SS door rails with floral glass etching for 1/3 portion of door area etc complete. The rate Sqm 10150.00
includes cost of all materials, labour, hire of tools & machineries, as per the specification.

Page No. 322

Page 230 of 350


39.7 Providing and fixing Single shutter glass door of 12mm thick frosted toughened glass of
approved make (Saint Gobain, Modi float). The door is fixed by using any approved make
hardware fitting like patch fitting, pivot, floor machine, locking arrangements and suitable
SS door rails with floral glass etching for 1/3 portion of door area etc complete. The rate Sqm 11200.00
includes cost of all materials, labour, hire of tools & machineries, as per specification.

39.8 Providing and fixing Double shutter glass door of 12mm thick frosted toughened glass of
approved make (Saint Gobain, Modi float). The door is fixed by using any approved make
hardware fitting like patch fitting, pivot, floor machine, locking arrangements and suitable
SS door rails with floral glass etching for 1/3 portion of door area etc complete. The rate Sqm 10630.00
includes cost of all materials, labour, hire of tools & machineries, as per specifications.

39.9 Providing, fabricating and fixing partition frame work consisting of 50mm x 50mm sal
wood frame work at spacing not exceeding 600mm c/c fixed to the bottom and ceiling, the
partition shall be skinned on both sides using 12mm thick commercial plywood of approved
brand termite and water resistance, and top covered with 4mm thick approved quality veneer
finished with melamine polish, complete including cost and conveyance of all materials, Sqm 8200.00
labour for all items of work, HOM of equipment as per specification. (P.No. 312, I.No. 39.9
of PWD SR 2015-16)

39.10 Removing wall paneling / false ceiling / wooden partition / aluminium partition, stacking it
with all cost and conveyance labour for all items of work, HOM of equipment etc., complete Sqm 60.00
as per specification. (P.No. 312, I.No. 39.10 of CSR 2015-16)
39.11 Providing and fixing 100mm wide venitian blinds of window fashion fabric of Taiwan
make, with 50mm thick powder coated channel with balance, imported, acrylic self alignable
mechanism and equally placed spacers, imported tilting mechanism for easy tilting
operation,with nylon imported thread and beadings, 100mm wide imported washable
reusable fabric placed with top hanger and bottom with 100mm long bottom plate connected
Sqm 950.00
to nylon imported bottom link chain. The rate is inclusive of drilling holes for fixing
channels to the wall, fixing threads and beadings and link chains, hard ware fixtures etc.,
complete as per drawing, specifications. (P.No. 312, I.No. 39.11 of CSR 2015-16)

Page No. 323


39.12 False ceiling Suspension system: False ceiling (Tiles, Panels) shall be suspended with the
frame work and Accessories complete from roof slabs, beams etc., by means of 4mm dia
galvanized rods, spring steel clips, hanger, Tee Runner, Ultra Look Tee Runner and edge
trim etc., The Suspnsion system consists of Grip bolt of size 50mm in length and dia of
9.5mm with 16mm long treads for fixing 9.2mm dia Nut, the thickness of the nut is 5.2mm,
this is also fixed with washer of 18.50mm in dia and the thickness of the washer is 0.80mm,
this grip bolt in fixed on to the RCC slab, by making holes with special hammering machine
and with the help of nut and washer, dip Galvanized Iron Rod of 4mm dia is rounded, then it
is been twisted, so that it with-rest above the washer and later on the nut is been tightened
and the grip bolt expands inside the RCC slab and holds the G.I.Rod 4mm thick straight, this
G.I. supporting rod of 4mm thick is also twisted on the other side of fixed “J” bolt, this “J”
bolt consists of 3mm thick with a length of 133mm, this “J” bolt is later on twisted by
26mm, this “J” bolt has a treaded portion of 47mm and this is provided with a nut of 3.63
mm thick and the dia of the nut is 6.9mm, this nut has a washer and this washer has a dia of
19mm and the thickness of 0.6mm and all this components are chromodised, later on
G.I.supporting rod of 4mm thick dia is twisted and fixed inside the nut and washer, then to
maintain a good, straight level of the false ceiling, the nut in “J” bolt is then moved up or
down for proper level. The Galvanized Iron 4 mm dia been cut to size of length required as
per site requirement. The pre-coated parametrical channel of 24mmx24mm, is been fixed on
to the wall at a prefect wall level and this pre-coated wall channel are having two coats of
primer and one coat of polyester paint of desired colour, the wall channel will have a coat of
primer applied on the rear side. This wall channel are made of galvanized Iron and the grade
of the galvanized Iron is as per BIS. This wall channel of 24mmx24mm is fixed on to the
wall side with the help of star screws, the star screws are having a length of 25mm and a dia
reducing basics of 3mm to tapered down. The main “T” consists of size: 24mm width x
38mm height, this main “T” is been made of galvanized Iron sheet of 0.3mm thick, this are
formed in the shape of a main”T” Bar on a fully automatic advance computer machine, the
galvanized iron sheet are later on capped with pre-coated aluminium capping will have the
colour, same as the panels colour or any other colour of choice. The grade of Galvanized
iron sheet in as per BIS and the grade of aluminium chapping is (Al-Mn) 3003 of H-46 to
48. The cross “T” bars are of 1200mm in lengthPage and
231this “T”s are of size 24mmx38mm in
of 350
height, another “T” bar consist 600mm in length and this “T”bar are of size 24mm width x
38mm in height, this “T” bar is fixed on to the main “T” of 24mmx38mm height and cross
per site requirement. The pre-coated parametrical channel of 24mmx24mm, is been fixed on
to the wall at a prefect wall level and this pre-coated wall channel are having two coats of
primer and one coat of polyester paint of desired colour, the wall channel will have a coat of
primer applied on the rear side. This wall channel are made of galvanized Iron and the grade
of the galvanized Iron is as per BIS. This wall channel of 24mmx24mm is fixed on to the
wall side with the help of star screws, the star screws are having a length of 25mm and a dia
reducing basics of 3mm to tapered down. The main “T” consists of size: 24mm width x
38mm height, this main “T” is been made of galvanized Iron sheet of 0.3mm thick, this are
formed in the shape of a main”T” Bar on a fully automatic advance computer machine, the
galvanized iron sheet are later on capped with pre-coated aluminium capping will have the
colour, same as the panels colour or any other colour of choice. The grade of Galvanized
iron sheet in as per BIS and the grade of aluminium chapping is (Al-Mn) 3003 of H-46 to
48. The cross “T” bars are of 1200mm in length and this “T”s are of size 24mmx38mm in
height, another
39.12.1 Mineral Fiber “T”
falsebar consist
ceiling 600mm inand
: Providing length andofthis
laying “T”bar
world classaremineral
of sizeacoustic
24mm width x
ceiling
38mm in
panels of height,
as per this
the “T” bar is fixed
following on to the main
specification:- Tile “T” of 24mmx38mm
of approved height and
make Mineral cross
Acoustic
tees of panels
ceiling 24mmx38mm height forms a pattern
of size 595x595mm-12mm thickofsuitable
600mmx600mm grid and
for use in arrears up further
to 40 Cthis
and grid
RH
work
70URis assupported by G.I.Rod of
per manufacturer. 4mm
Tile and 15
have height
minadjustable “J” bolts
fire retardant system.
and does Thenot “T” grid
contain
system consists
asbestos/urea of special steel
formaldehyde, is as perdetails
Technical BIS, andof the
Newthickness
Modenaofare-theThermal
steel is 0.3mm thick.
conductivity Sqm 2100.00
This “T” frame work
Non-disposable, Light isReflection
capped with 80%coilfire
coated aluminum
resistance sheet and the
Non-resistance grade of the
Non-disposable.
Aluminum
Mineral sheet
fiber is (Al-Mn)
ceiling panels3003 of H-46inside
are placed to H-48the grid work. (P.No. 313, I.No. 39.12.1 of
CSR 2015-16)

Page No. 324


39.12.2 PVC laminated false ceiling Supply & installation of PVC
laminated false ceiling size of 600x600mmx9mm as per the following specification:- Panels
are PVC laminated on the finish side and backed with aluminum foil (behind). It shall be
suspended with the frame work and accessories completed from roof slabs, beams etc., by Sqm 2710.00
means of 4mm dia galvanized rods, J bolt, Tee runner, Ultra look Tee Runner and edge trim
etc.

39.12.3 Stainless steel false ceiling Providing & fixing of acoustical & fire retardant tile ceiling
system comprising of tiles 600 x 600 mm long fabricated from 0.90mm aluminum sheet.
The tiles shall be suspended with the frame work etc., Complete from the slab beams etc., by
means of 4mm dia G.I.rods, G.I.sanp bar at 1200 mm centre to centre, G.I.snap couplings,
G.I.sanp bar hangers, G.I.edge profile etc., Installation: The top portion of rod shall be
rounded and shall be screwed to slab by means of providing grip bolts 5mm long and other
end shall be bolted by means of providing 3/16’x1/2 ‘ machine screws and 3/16’ nut for
leveling in to the snap bar hanger 1.2 meter to 2.00 meter centre to centre. The distance Sqm 10990.00
between two snap bars shall be 1200 mm centre to centre, The snap bar shall be fixed into
the snap bar. The pressure clip shall be provided along the length of the tile flange to hold
the panels in line and level at suitable distance, as required. The edge profile shall be fixed at
the perimeter of the false ceiling area.

39.12.4 Aluminum plain/perforated/Mirror finish false ceiling VT-35 mm (Vertical drop 35 mm)
Providing, supplying and erection false ceiling with lay in tile system with aluminum
powder coated tiles-Boxer type VT-35 mm fabricated from special aluminum grade
3003/100(Al-Mn) of H-46 to H-48 boxer type panels with Non-metallic finish. Panel
details:- The good quality fully finished ceiling systems consists of Aluminum powder
coated false ceiling panels comprising 595mmx595mmx 35mm H. This panels are tapered
out on all the four sides sloping towards inside and the size is 565mmx565mm. The panels
are non combustible fire proof This panels has excellent Aesthetic look and the panels are
made out of special imported powder coated aluminum sheet of 0.8mm thick the sheets
consists of Aluminum alloy of AA 3003/1100. This special fully finish panels will have
solution one where the panels will go drop down by 35 mm and solution two where the Sqm 6610.00
panels will go up by 35mm. This panel also have above got perforation and the dia of the
perforation is 2mm and the distance between one perforation to another perforation is
10.00mm centre to centre the perforation in the panels are in straight line. These panel are
provide with sound absorption mat. (P.No. 314, I.No.39.12.4 of PWD SR 2015-16)

Page 232 of 350


39.12.5 Aluminum plain/perforated/Mirror finish false ceiling VT-09 (Vertical drop 9mm)
Supply and installation of Aluminum powder coated false ceiling proof panel size
600x600mmx9mm drop, Noncombustible fire proof humidity proof, Aesthetic, fabricated
from enameled coated sheet of thickness 0.8mm, panel shall be painted by powder coating
process with polyester paints and with secular mirror finish, shining lacquered plain or Sqm 6885.00
decorated on outer surface. It shall be suspended with the frame work and accessories
complete from roof slabs, beams etc., by means of 4mm dia GO J bolt Tee runner, ultra look
Tee Runner and edge trim etc., Specifications of Boxer Panels:- These Boxer type panels are
available in both perforated and un perforated with oblique edges The un perforated panels
are available in plain colours and different designs The panel size is 600x600x9mm When
perforated, the panel shall have 2mm Page No. 325
square perforation These perforated panels are
39.13 provided by non woven
COURT HALL FURNITURE fabric & is adhered to the inside of the panel
39.13.1 COURT HALL FURNITURE DIAS for Judges Providing and fixing dias for judges in
court halls of overall size 3650 x 3050 x 600 mm using 40 x 40 x 2mm slotted angle for
frame work at suitable intervals using double angle back to back wherever necessary with
suitable stiffeners for legs including diagonal members fabricated using nuts and bolts, the
top of the dias to be covered with 25mm treated commercial block board of approved make,
seated and fastened properly by bolt and nut to the slotted angle frame work, the sides of the
dias to be covered with 12mm thick novopan sheet fixed firmly to the slotted angle,
including making a parapet alround the dias to a height of 750mm using the slotted angle Sqm 8100.00
frame work and covered with novopan sheet of 12mm thick for outside and 4mm thick one
side teak plywood for inside of the parapet with 50x25mm sal wood frame work attached to
the slotted angle, the top of the parapet is fixed with 20mm teak wood ornamental beeding
alround including cost of all materials and labour, painting, lead and lift and as per the
direction of engineer-in-charge of work. and also as per drawing appended.

39.13.2 COURT HALL FURNITURE Teak wood platform Providing and fixing wooden platform
of overall size 2450x1850x175mm using teak wood of section 50x50mm of legs, 50x50mm
for horizontals both at suitable intervals from the point of view of stability, the top of the
platform covered with commercial block board of 25mm thick, all sides covered with 6mm
thick one side teak plywood fixed firmly to the platform including joining the wooden
Sqm 7060.00
sections properly using nails/screws, fevicol including cost of wood, nails/screws, fevicol,
cost of painting/polishing, labour, all lead and lift, cost of any incidental charges etc.,
complete and as per the drawing (appended) and direction of engineer-in-charge of work.

39.13.3 COURT HALL FURNITURE Horse Shoe Table Providing and fixing “HORSE SHOE
TABLE” of overall size 4500 x 2200x 750mm using teak wood of size 100x100mm for legs
at suitable intervals, 50x75mm section for horizontal support at top, 50x100mm section
horizontal support at bottom as shown in figure. The top of the table which should be
600mm in width all along, is covered with 19mm thick block board and 1.50mm thick
formica sheet fixed on top of the block board, all of approved make. The inside vertical
surface is covered with 6mm thick one side teak plywood, including providing teak wood Sqm 11000.00
beeding alround the table for good aesthetic appearance, including joining the wooden
sections properly using nails/screws, fevicol including cost of wood, nails/screws, fevicol,
cost of painting/ polishing, labour, all lead and lift, cost of any incidental charges etc.,
complete and as per the drawing (appended) and direction of engineerin- charge of work.
(P.No. 315/I.No. 39.13.3 of CSR 2015-16)

Page No. 326


39.13.4 COURT HALL FURNITURE Teak wood witness box Providing and fixing
witness box of overall size 1200x750x1350mm with one side door way as shown in figure
using teak wood of size 75x75mm for legs, 50x75mm size for horizontal support at top and
bottom, and 25x50mm size section for verticals between legs with a spacing of 150mm
including fixing 19mm thick commercial block board for full area at bottom and for a length
of 300mm at top to facilitate keeping the file during the course of witness including joining each 27700.00
the wooden sections properly using nails/screws, fevicol including cost of wood,
nails/screws, fevicol, cost of painting/polishing, labour, all lead and lift, cost of any
incidental charges etc., complete and as per the drawing (appended) and direction of
engineer-in-charge of work.

Page 233 of 350


39.13.5 COURT HALL FURNITURE Teak wood Accused box Providing and fixing accused
box of overall size 3000x1150x1350mm with one side door way as shown in figure using
teak wood of size 75x75mm for legs, 50x75mm size for horizontals at top and bottom and
25x50mm size for verticals between legs with a spacing of 150mm including fixing 19mm
thick commercial board for full area at bottom, including joining the wooden sections
properly using nails/screws, fevicol including cost of wood, nails/screws, hinges, locking each 42000.00
arrangements for the opening, fevicol, cost of painting/polishing, labour, all lead and lift,
cost of any incidental charges etc., complete and as per the drawings (appended) direction of
engineer-in-charge of work.

39.14 STRAIGHT WORKSTATION (Frame and separator) Providing and fixing


STRAIGHT WORKSTATION consisting of back to back unit made out of 75 mm thick
MS CRCA powder coated ,tile based system for main sprine, Separator 25 mm tghick PLPB
- BSL wooden separator for return spine,Top tile finish 8 mm thick MDF covered with
Fabric of approved colour and one writing board ( 600 mmw) and one soft board ( 600 mmw
) per workstation,Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway-
one middle raceway ( 600mmW ) below table top per workstation and continous raceway at
the skirting level,Wir e manager- ABS plastic grommet one number per table,Table top - 25
mm thick PLPB with straight table top Hardware_ MS powder coated corner bkt,cantilever
bkt,separator hook on bkt, L bkt and Table joint plate., as per specifications , drawings and
as directed by Engineer in charge

Page No. 327


39.14.1 Sharing workstation 1A ) Size : 1200 mmW x 600mm D x 1200 mm ht -(Sharing - Edge
No 20200.00
binding table top): Back to Back (set of 2)
39.14.2 Sharing workstation 1B ) Size : 1200 mmW x 540mm D x 1200 mm ht - (Sharing-Post
No 19500.00
formed table top): Back to Back (set of 2)
39.14.3 Non Sharing workstation 1C) Size : 1200 mmW x 600mm D x 1200 mm ht (Non Sharing-
No 13250.00
Edge binding table top): single unit
39.14.4 Non Sharing workstation 1D ) Size : 1200 mmW x 540mm D x 1200 mm ht (Non Sharing-
No 14550.00
Post formed table top) single unit
39.15 STRAIGHT WORKSTATION (Frame): Providing and fixing STRAIGHT
WORKSTATION ( Frame ) consisting of back to back unit made out of 75 mm thick MS
CRCA powder coated, tile based system for main and return spine, Top tile finish 8 mm
thick MDF covered with Fabric of approved colour and one writing board (600 mm w) and
one soft board ( 600 mmw ) per workstation,Bottom tile finish 9 mm thick Laminate tile of
approved colour, Raceway- one middle raceway ( 600mmW ) below table top per
workstation and continous raceway at the skirting level, Wire manager- ABS plastic
grommet one number per table,Table top - 25 mm thick PLPB with straight table top End
Table 25 mm thick PLPB with straightedge bound Hardware-MS powder coated corner
bkt,cantilever bkt,separator hook on bkt, L bkt and Table joint plate., as per specifications ,
drawings and as directed by Engineer in charge Sharing workstation. (P.No. 317, I.No.
39.15.2 of PWD SR 2015-16)

39.15.1 Sharing workstation 2A ) Size : 1200 mmW x 600mm D x 1200 mm ht -(Sharing -


No 24450.00
Edgebinding table top): Back to Back (set of 2)
39.15.2 Sharing workstation 2B ) Size : 1200 mmW x 540mm D x 1200 mm ht - (Sharing-
No 25500.00
Postformed table top): Back to Back (set of 2)
39.15.3 Non Sharing workstation 2C) Size : 1200 mmW x 600mm D x 1200 mm ht (Non Sharing-
No 16060.00
Edgebinding table top): single unit
39.15.4 Non Sharing workstation 2D ) Size : 1200 mmW x 540mm D x 1200 mm ht (Non Sharing-
No 16750.00
Postformed table top): single unit
Page No.328

Page 234 of 350


39.16 CUBICLE WORKSTATIONS : Providing and fixing CUBICLE WORKSTATIONS
consisting of wings made out of 75 mm thick MS CRCA powder coated ,tile based system
for main and return spine, Top tile finish 8 mm thick MDF covered with Fabric of approved
colour and one writing board (600 mm w) and one soft board (600 mmw) per workstation,
Bottom tile finish 9 mm thick Laminate tile of approved colour, Raceway- one middle
raceway (600mmW) below table top per workstation and continous raceway at the skirting
level, Wire manager- ABS plastic grommet one number per table,Table top - 25 mm thick
PLPB with straight table top End Table 25 mm thick PLPB with straightedge bound
Hardware-MS powder coated corner bkt, cantilever bkt, separator hook on bkt, L bkt and
Table joint plate., as per specifications , drawings and as directed by Engineer in charge.
(P.No. 318, I.No. 39.16.2 of PWD SR 2015-16)

39.16.1 X TYPE 4 wings 3A) Size : 1500 mmW x 1200mm D x 1200 mm ht : Unit 56000.00
39.16.2 X TYPE 4 wings 3B) Size : 1500 mmW x 1500mm D x 1200 mm ht: Unit 69500.00
39.16.3 T TYPE 2 wings 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht Unit 35900.00
39.16.4 T TYPE 2 wings 3D) Size : 1500 mmW x 1500mm D x 1200 mm ht : Unit 53000.00
39.16.5 C TYPE 2 wings 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht: Unit 39100.00
39.16.6 C TYPE 2 wings 3D) Size : 1500 mmW x 1500mm D x 1200 mm ht: Unit 57800.00
39.16.7 L TYPE one wing 3C) Size : 1500 mmW x 1200mm D x 1200 mm ht: Unit 23600.00
39.16.8 L TYPE one wing 3D) Size : 1500 mmW x 1500mm D x 1200 mm ht: Unit 26200.00
39.17 FREE STANDING TABLE FOR CABIN - WITHOUT FRAMES Providing and fixing
Free Standing Table for Cabin- without frames consisting of 25 mm thick PLPB table top ,
25 mm thick PLPB with edge bomded End table,18 mm thick PLPB with edge bonded
Modesty, Wire manager -ABS plastic grommet one number per table Hardware-Minifix
assembly and screw leg., as per specifications, drawings and as directed by Engineer in
charge

39.17.1 Main Table : 1500 mmW x 750mm D x 750 mm ht (Edgebinding table top) Side Table : 900
No 13400.00
mm W x 450mm D X 750 mm ht. (P.No. 318/ I.No. 39.17.1 of CSR 2015-16)
39.17.2 Main Table : 1500 mmW x 750mm D x 750 mm ht (Post formed table top) Side Table : 900
No 12000.00
mm W x 450mm D X 750 mm ht
Page No. 318
39.18 FREE STANDING TABLE FOR CABIN - WITHOUT FRAMES Providing and fixing
Free Standing Table for Cabin- without frames consisting of 25 mm thick PLPB table top ,
25 mm thick PLPB with edge bonded End table,18 mm thick PLPB with edge bonded
Modesty, Wire manager -ABS plastic grommet one number per table Hardware-Minifix
assembly and screw leg., as per specifications, drawings and as directed by Engineer in
charge

39.18.1 1200 mmW x 600mm D x 750 mm ht (Edgebinding table top) No 7850.00


39.18.2 1500 mmW x 600mm D x 750 mm ht (Edgebinding table top) No 8800.00
39.18.3 1200 mmW x 540mm D x 750 mm ht (Post formed table top No 8170.00
39.18.4 1500 mmW x 540mm D x 750 mm ht (Post formed table top) No 8450.00
39.19 Discussion table - wooden Providing and fixing discussion table wooden consisting of 25
mm thick PLPB table top edge bounded, 25 mm thick PLPB with edge bonded End table,
Hardware-Minifix assembly and screw leg., as per specifications, drawings and as directed
by Engineer in charge
39.19.1 600 mm Dia X 750 mm Ht ( 4 seater ) No 4750.00
39.19.2 750 mm Dia X 750 mm Ht ( 4 seater ) No 5825.00
39.19.3 900 mm Dia X 750 mm Ht ( 4 seater ) No 6450.00
39.20 Discussion table - Metal leg Providing and fixing discussion table metal leg consisting of
25 mm thick PLPB table top edge bounded MS CRCA sheet round plate at bottom and 75
mm dia pol at centre with 25 X 25 tube welded at top Hardware-L bkt and screw leg ., as per
specifications, drawings and as directed by Engineer in charge
39.20.1 600 mm Dia X 750 mm Ht ( 4 seater ) No 7500.00
39.20.2 750 mm Dia X 750 mm Ht ( 4 seater ) No 10000.00
39.20.3 900 mm Dia X 750 mm Ht ( 4 seater ) No 10500.00

Page 235 of 350


39.21 Meeting table -wooden : Providing and fixing meeting table consisting of 25 mm thick
PLPB table topedge bounded, 25 mm thick PLPB with edge bonded End table,18 mm thick
PLPB with edge bonded Modesty, Hardware-Minifix assembly and screw leg., as per
specifications, drawings and as directed by Engineer in charge
39.21.1 1500 mm Dia X900 mm D X 750 mm Ht (6 seater) No 13500.00
39.21.2 2400 mm Dia X1200 mm D X 750 mm Ht (12 seater) No 22500.00
39.22 Providing and fixing conference table consisting of 25 mm thick PLPB table top edge
bounded, 25 mm thick PLPB with edge bonded End table,18 mm thick PLPB with edge
bonded Modesty, Hardware-Minifix assembly and screw leg., as per specifications, drawings Rmt 71500.00
and as directed by Engineer in charge 4800 mmX 2400mm X 750 mm Ht (20 seater) - U
shaped with a top width of 600 mm. (P.No. 320, I.No. 39.22 of CSR 2015-16)
Page No. 330
39.23.1 Modular Partition: Providing and fixing modular partition consisting of 75mm thick MS
CRCA frames powder coated, tile based system frame, 8mm thick MDF covered with Fabric
of approved colour for Top file finish, 5mm thick clear ordinary glass both side Middle tile
finish, or 8mm thick MDF covered with Fabric of approved colour for Middle tile finish,
9mm thick Laminate tile of approved colour for Botom tile finish, Continuous skirting level Sqm 5380.00
raceway will be provided. as per specifications, drawings and as directed by Engineer in
charge. 75mm thick frames tile based system (Frame with Tile). (P.No. 320, I.No. 39.23.1
of PWD SR 2015-16)

39.23.2 Modular Partition: Providing and fixing modular partition consisting of 75mm thick MS
CRCA frames powder coated, tile based system frame, 8mm thick MDF covered with Fabric
of approved colour for Top file finish, 5mm thick clear ordinary glass both side Middle tile
finish, or 8mm thick MDF covered with Fabric of approved colour for Middle tile finish,
9mm thick Laminate tile of approved colour for Botom tile finish, Continuous skirting level Sqm 5900.00
raceway will be provided. as per specifications, drawings and as directed by Engineer in
charge. 75mm thick frames tile based system (Frame with Glass). (P.No. 320, I.No.
39.23.2 of PWD SR 2015-16)

39.24 Storage Unit - wooden - One side laminate: Providing and fixing woode storage unit one
side laminate with 18 mm PLY/PLPB with edge bound for body, 18mm PLY/PLPB with
openable shutters and individual locking system for shutter, 9 mm PLY with edge bound for
rear portion with Hafele fitting hinges, Hafele locks,Minifix assembly, screw legs, Handles
and tower bolt. complete as per specifications, drawings and as directed by Engineer in
charge

39.24.1 PLY STORAGE 900 mm W X 430 mm D X 750 mm No 7800.00


39.24.2 PLY STORAGE 900 mm W X 430 mm D X 1200 mm No 11200.00
39.24.3 PLY STORAGE 900 mm W X 430 mm D X 2100 mm Ht No 19800.00
39.24.4 PLPB STORAGE 900 mm W X 430 mm D X 750 mm Ht No 7650.00
39.24.5 PLPB STORAGE 900 mm W X 430 mm D X 1200 mm Ht No 11000.00
39.24.6 PLPB STORAGE 900 mm W X 430 mm D X 2100 mm Ht No 19000.00
39.25 Mobile pedestal unit- WOODEN : Providing and fixing 450mmw X 450 mmd X 685
mmht ) Mobile pedestal unit-WOODEN with 18mm thick PLPB with edge bonded for body,
Two equal drawer and filing drawer with centralized locking system, Telescopic channels, No 5500.00
castors, Handles and lock etc., complete as per specifications, drawings and as directed by
Engineer in charge. (P.No. 320, I.No. 39.25 of SR 2015-16)
39.26 Mobile pedestal unit- METAL: Providing and fixing 450mmw X 450 mmd X 685 mmht )
Mobile pedestal unit- Metal with MS CRCA sheet powder coated for body, Two equal
drawer and one filing drawer with centralized locking system, Telescopic channels, castors, No 7000.00
Handles and lock etc., complete as per specifications, drawings and as directed by Engineer
in charge.
39.27 Mobile pedestal unit- METAL with wooden facia : Providing and fixing 450mmw X 450
mmd X 685 mmht ) Mobile pedestal unit- Metal with wooden facia made of MS CRCA
sheet powder coated for body, 18 mm thick PLPB with edge bonded facia, Two equal
drawer and one filing drawer with centralized locking system, Telescopic channels, castors, No 6500.00
Handles and lock etc., complete as per specifications, drawings and as directed by Engineer
in charge

Page No. 331

Page 236 of 350


40.0 40.FIRE FIGHTING WORK

40.1 Providing ABC Powder based MAP 50, 1Kg


Providing 1kg Fire Extinguisher Mono Ammonium Phosphate Powder
50, Stored Pressure Type, Pressure Gauge, Gross Weight 2.3 Kg, empty
weight 1.3 Kg, Can Height 298MM, Diameter 86.50MM, Discharge
Time less than 8 Secs, Controllable discharge mechanism (Squeeze
grip with easy snap safety seal), Range minimum 2 meters, applicable
on Class A,B,C and electrically started Fire, A Rating 1A, B Rating 8B, each 2574.00
Can construction : Deep drawn & Co., Mig welded, valve Construciton :
Forging and Mechining, Internal Coating of Can: Epoxy powder coating,
External Coating of Can: Epoxy Polyster power coating, Sheet metal
thickness: 1.60MM, 5 years Warranty with instalert system etc., complete

40.2 Providing ABC Powder based MAP 50, 2Kg


Providing 2kg Fire Extinguisher Mono Ammonium Phosphate
Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight
3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM,
Discharge Time less than 8 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum
2 meters, applicable on Class A,B,C and electrically started Fire, each 3861.00
A Rating 1A, B Rating 8B, Can construction : Deep drawn & Co., Mig
welded, valve Construciton : Forging and Mechining, Internal Coating of
Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power
coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete.

40.3 Providing ABC Powder based MAP 50, 4Kg


Providing 4kg Fire Extinguisher Mono Ammonium Phosphate
Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight
6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM,
Discharge Time less than 13 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 2A, B Rating 21B, Can construction : Deep drawn & Co., each 5362.00
Mig welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy
Polyster power coating, Sheet metal thickness: 1.60MM, Helium Leak
Detection Tested, ISI and EN Approved, 5 years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

40.4 Providing ABC Powder based MAP 50, 6Kg


Providing 6kg Fire Extinguisher Mono Ammonium Phosphate
Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight
9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM,
Discharge Time less than 9 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 3A, B Rating 21B, Can construction : Deep drawn & Co., Mig each 6517.00
welded, valve Construciton : Forging and Mechining, Internal Coatingof Can: Epoxy
powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 1.60MM, Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 340

Page 237 of 350


40.5 Providing ABC Powder based MAP 50, 9Kg
Providing 9kg Fire Extinguisher Mono Ammonium Phosphate
Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight
14.90 Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter
175MM, Discharge Time less than 13Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 4A, B Rating 34B, Can construction : Deep drawn & Co., each 8580.00
Mig welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy
Polyster power coating, Sheet metal thickness: 2.00MM, Helium Leak
Detection Tested, ISI and EN Approved, 5 years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

40.6 Providing ABC Powder based MAP 90, 2Kg


Providing 2 kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight
3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM,
Discharge Time less than 8 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum
2 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 1A, B Rating 8B, Can construction : Deep drawn & Co., each 4950.00
Mig welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy
Polyster power coating, Sheet metal thickness: 1.60MM, Helium Leak
Detection Tested, ISI and EN Approved, 5 years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

40.7 Providing ABC Powder based MAP 90, 4Kg


Providing 4kg Fire Extinguisher Mono Ammonium Phosphate
Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight
6.9 Kg, empty weight 2.9 Kg, Can Height 440MM, Diameter 140MM,
Discharge Time less than 13 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 2A, B Rating 21B, Can construction : Deep drawn & Co., Mig each 6930.00
welded, valve Construciton : Forging and Mechining, Internal Coating
of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 1.60MM, Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.8 Providing ABC Powder based MAP 90, 6Kg


Providing 6kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight9.40 Kg, empty weight 3.4
Kg, Can Height 480MM, Diameter
160MM, Discharge Time less than 13 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 3A, B Rating 21B, Can construction : Deep drawn & Co., each 8580.00
Mig welded, valve Construciton : Forging and Mechining, Internal Coating
of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 1.60MM, Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 341

Page 238 of 350


40.9 Providing ABC Powder based MAP 90, 9Kg
Providing 9kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight
14.9 Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter
175MM, Discharge Time less than 13Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range minimum
4 meters, applicable on Class A,B,C and electrically started Fire,
A Rating 4A, B Rating 34B, Can construction : Deep drawn & Co., each 14079.00
Mig welded, valve Construciton : Forging and Mechining, Internal Coating
of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 2.00 MM, Helium Leak Detection
Tested, ISI and EN Approved, 5 years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.10 Providing ABC Powder based MAP 90, 25Kg Providing 25kg Fire Extinguisher Mono
Ammonium Phosphate Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight
76Kg, empty weight 51 Kg, Can Height 1200 MM, Diameter 300 MM, Discharge Time less
than 30 Secs, Controllable discharge mechanism (Squeeze grip with easy snap safety seal),
Range minimum 6 meters, applicable on Class A,B,C and electrically started Fire, Can
construction : Deep drawn & Co., Mig welded, valve Construciton: Forging and Mechining,
Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster each 33000.00
power coating, Sheet metal thickness: 4.00 MM, 1 year Warranty. with instalert system with
Superior quality EPDM Rubber Hosepipe etc., complete

40.11 Providing Ceiling mounted 5 Kg


Providing 5kg Fire Extinguisher Mono Ammonium Phosphate Powder
90, Stored Pressure Type, Pressure Gauge, Gross Weight 7.7Kg,
empty weight 2.7 Kg, Can Height 264 MM, Diameter 240 MM,
Discharge Time less than 8 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 10 meters,
applicable on Class A,B,C and electrically started Fire, Can construction each 12099.00
: Deep drawn & Co., Mig welded, valve Construciton : Forging and
Mechining, Internal Coating of Can: Epoxy powder coating, External
Coating of Can: Epoxy Polyster power coating, Sheet metal thickness:
2.00 MM, Helium Leak Detection Tested, 5 years warranty. etc., complete

Page No. 342


40.12 Providing 10Kg Ceiling Mounted
Providing 10kg Fire Extinguisher Mono Ammonium Phosphate
Powder 90, Stored Pressure Type, Pressure Gauge, Gross Weight
14.8Kg, empty weight 4.8 Kg, Can Height 320 MM, Diameter 300 MM,
Discharge Time less than 10 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 10
meters, applicable on Class A,B,C and electrically started Fire, Can each 18589.00
construction : Deep drawn & Co., Mig welded, valve Construciton : Forging
and Mechining, Internal Coating of Can: Epoxy powder coating, External
Coating of Can: Epoxy Polyster power coating, Sheet metal thickness:
2.00 MM, Helium Leak Detection Tested, 5 years warranty. etc., complete

40.13 Providing 1 Kg Fire Extinguisher Monnex powder


Providing 1kg Stored Pressure Type, Pressure Guage, Gross
Weight 2.7 Kg, empty weight 1.7 Kg, Can Height 344 MM, Diameter
108MM, Discharge Time less than 8 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, applicable on Class A,B and electrically started
Fire, B Rating 89B, Can construction : Deep drawn & Co., Mig each 5940.00
welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 1.60 MM,
5 years warranty.with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

Page 239 of 350


40.14 Providing 2 Kg Fire Extinguisher Monnex powder
Providing 2kg Stored Pressure Type, Pressure Guage, Gross Weight
4.9 Kg, empty weight 2.9 Kg, Can Height 440 MM, Diameter 140 MM,
Discharge Time less than 9 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 4 meters,
applicable on Class A,B and electrically started Fire, Very effective on
Class B Fire, B Rating 144B, Can construction : Deep drawn & Co., Mig each 9240.00
welded, valve Construciton : Forging and Mechining, Internal Coating of
Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 1.60 MM, 5 years warranty. with
instalert system with Superior quality EPDM Rubber Hosepipe etc.,
complete

40.15 Providing 4 Kg Fire Extinguisher Monnex powder


Providing 4kg Stored Pressure Type, Pressure Guage, Gross
Weight 7.4Kg, empty weight 3.4 Kg, Can Height 480 MM, Diameter
160 MM, Discharge Time less than 13 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, Can construction : Deep drawn & Co., Mig
welded, valve Construciton : Forging and Mechining, Internal each 15510.00
Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 1.60 MM,
5 years warranty. with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

Page No. 343


40.16 Providing 4 Kg Fire Extinguisher for Lite metal fires SPM-TEC
Providing 4kg SPM-TEC Powder Based stored presure type melting
point at 600-650 degree C, Applicable on Class D metal fires in
Magnesium, Aluminium, Zinc, Sodium Potassium, Francium, Lithium,
Cesium, Pressure Guage, Gross weight Gross Weight 6.9Kg, empty
weight 2.9 Kg, Can Height 440 MM, Diameter 140 MM, Discharge
Time less than 15 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 4 meters, each 11880.00
Can construction : Deep drawn & Co., Mig welded, valve Construciton
: Forging and Mechining, Internal Coating of Can: Epoxy powder
coating, External Coating of Can: Epoxy Polyster power coating,
Sheet metal thickness: 1.60 MM, helium leak detection tested,
EN approved, 5 years warranty with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete

40.17 Providing 6 Kg Fire Extinguisher for Lite metal fires SPM-TEC


Providing 6kg SPM-TEC Powder Based stored presure type melting
point at 600-650 degree C, Applicable on Class D metal fires in
Magnesium, Aluminium, Zinc, Sodium Potassium, Francium, Lithium,
Cesium, Pressure Guage, Gross weight Gross Weight 9.4Kg, empty
weight 3.4 Kg, Can Height 480 MM, Diameter 160 MM, Discharge
Time less than 16 Secs, Controllable discharge mechanism (Squeeze
grip with easy snap safety seal), Range minimum 4 meters, Can each 16500.00
construction : Deep drawn & Co., Mig welded, valve Construciton
: Forging and Mechining, Internal Coating of Can: Epoxy powder
coating, External Coating of Can: Epoxy Polyster power coating,
Sheet metal thickness: 1.60 MM, helium leak detection tested,
EN approved, 5 years warranty. with instalert system with Superior
quality EPDM Rubber Hosepipe etc., complete

Page 240 of 350


40.18 Providing 9 Kg Fire Extinguisher for Lite metal fires SPM-TEC
Providing 9kg SPM-TEC Powder Based stored presure type melting point
at 600-650 degree C, Applicable on Class D metal fires in Magnesium,
Aluminium, Zinc, Sodium Potassium, Francium, Lithium, Cesium, Pressure
Guage, Gross weight Gross Weight 14.9Kg, empty weight 5.9 Kg, Can Height
615 MM, Diameter 175 MM, Discharge Time less than 18 Secs, Controllable
discharge mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, Can construction : Deep drawn & Co., Mig welded, each 23100.00
valve Construciton : Forging and Mechining, Internal Coating of Can:
Epoxy powder coating, External Coating of Can: Epoxy Polyster power
coating, Sheet metal thickness: 2.00 MM, helium leak detection tested,
EN approved, 5 years warranty with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete

40.19 Providing 4 Kg Fire Extinguisher for Heavy metal fires SPM-PYRO


Providing 4 Kg Powder Based stored presure type melting
point at 1200 degree C, Applicable on Class D metal fires in
heavy metals, alkali metals and alloys Pressure Guage, Gross
weight Gross Weight 6.9Kg, empty weight 2.9 Kg, Can Height
440 MM, Diameter 140 MM, Discharge Time less than 15 Secs,Controllable discharge
mechanism (Squeeze grip with easy snap safety each 26400.00
seal), Range minimum 4 meters, Can construction : Deep drawn &
Co., Mig welded, valve Construciton : Forging and Mechining, Internal
Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy
Polyster power coating, Sheet metal thickness: 1.60 MM, helium leak
detection tested, EN approved, 5 years warranty.complete

Page No. 344


40.20 Providing 6Kg Fire Extinguisher for Heavy metal fires SPM-PYRO
Providing 6Kg Powder Based stored presure type melting point at 1200
degree C, Applicable on Class D metal fires in heavy metals, alkali metals
and alloys Pressure Guage, Gross weight Gross Weight 9.4Kg, empty
weight 3.4 Kg, Can Height 480MM, Diameter 160 MM, Discharge Time
less than 16 Secs, Controllable discharge mechanism (Squeeze grip
with easy snap safety seal), Range minimum 4 meters, Can construction each 39600.00
: Deep drawn & Co., Mig welded, valve Construciton : Forging and
Mechining, Internal Coating of Can: Epoxy powder coating, External Coating
of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60 MM,
helium leak detection tested, EN approved, 5 years warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

40.21 Providing 9 Kg Fire Extinguisher for Heavy metal fires, SPM-PYRO


Providing 9Kg Powder Based stored presure type melting point
at 1200 degree C, Applicable on Class D metal fires in heavy
metals, alkali metals and alloys Pressure Guage, Gross Weight
14.9Kg, empty weight 5.90 Kg, Can Height 615MM, Diameter
175 MM, Discharge Time less than 18 Secs, Controllable discharge
mechanism (Squeeze grip with easy snap safety seal), Range
minimum 4 meters, Can construction : Deep drawn & Co., Mig welded, each 59400.00
valve Construciton : Forging and Mechining, Internal Coating of
Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster
power coating, Sheet metal thickness: 2.00 MM, helium leak detection
tested, EN approved, 5 years warranty with instalert system with Superior
quality EPDM Rubber Hosepipe etc., complete

Page 241 of 350


40.22 Providing 2Kg Fire Extinguisher Clean Agent HCFC 123
Providing 2Kg Pressure type, Pressure Guage, Gross Weight 3.7Kg,
empty weight 1.7 Kg, Can Height 344MM, Diameter 108 MM, Discharge
Time less than 8 Secs, Controllable discharge mechanism (Squeeze
grip with easy snap safety seal), Range minimum 2 meters, applicable on
Class A,B,C and electrically started Fire, B Rating 21B, Can construction :
Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, each 18150.00
Internal Coating of Can: Epoxy powder coating, External Coating of Can:
Epoxy Polyster power coating, Sheet metal thickness: 2.00 MM, helium
leak detection tested, EN approved, 5 years warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.23 Providing 4 Kg Fire Extinguisher Clean Agent HCFC 123


Providing 4Kg Stored Pressure Type, Pressure Gauge, Gross Weight
6.9 kg empty weight 2.9 kg Can Height 440MM, Diameter 140 MM,
Discharge minium 9 Secs, Controllable discharge mechanism (Squeezegrip with easy snap
safety seal), Range minimum 4 Meters, applicable
on Class A,B,C and electrically started Fire, A Rating 1A, B Rating
13B Can Construction; Deep drawn & CO, Mig welded, Valve Construction: each 36079.00
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, EN Approved,
5 years warranty with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

Page No. 345


40.24 Providing 6 Kg Fire Extinguisher Clean Agent HCFC 123
Providing 6Kg Stored Pressure Type, Pressure Gauge, Gross Weight
9.4kg. empty weight 3.4 kg Can Height 480MM, Diameter 160 MM,
Discharge Time less than 13 Secs, Controllable discharge mechanism
(Squeeze grip with easy snap safety seal), Range minimum 4 Meters,
applicable on Class A,B,C and electrically started Fire, A Rating 2A,
B Rating 21B Can Construction; Deep drawn & CO, Mig welded, Valve each 51039.00
Construction: Forging & Machining, Internal Coating of Can : Epoxy Powder
coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet
metal thickness: 1.60MM, Helium Leak Detection Tested, EN Approved,
5 years warranty with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.25 Providing 5Kg Ceiling Mounted Fire Extinguisher Clean Agent


HCFC 123
Providing 5Kg Stored Pressure Type, Pressure Gouge, Gross Weight
7.7kg. empty weight 2.7 kg Can Height 267MM, Diameter 230 MM,
Discharge Time less than 8Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire, each 46859.00
Can Construction; Deep drawn & CO, Mig welded, Valve Construction:
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, 5 Years Warranty

40.26 Providing 10Kg Ceiling Mounted Fire Extinguisher Clean Agent


HCFC 123
Providing 10Kg Stored Pressure Type, Pressure Gouge, Gross Weight
14.8kg. empty weight 4.8 kg Can Height 316MM, Diameter 300 MM,
Discharge Time less than 10Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire, each 74799.00
Can Construction; Deep drawn & CO, Mig welded, Valve Construction:
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 2.0MM, Helium Leak Detection Tested, 5 Years Warranty

Page 242 of 350


40.27 Providing 2Kg Fire Extinugisher Clean Agent FE36 Dupont
Providing 2Kg Stored Pressure Type, Pressure Gauge, Gross Weight
3.70kg. empty weight 1.7 kg Can Height 344MM, Diameter 108 MM,
Discharge Time minimum 8 Secs, Controlable discharge mechanism,
Range minimum 2 Meters, applicable on Class A,B,C and electrically
started Fire B, Rating 8B, Can Construction; Deep drawn & CO,Mig welded, Valve
Construction: Forging & Machining, Internal Coating of Can each 25849.00
: Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder
coating, Sheet metal thickness: 1.60MM, Helium Leak Detection Tested,
5 Years Warranty with instalert system with Superior quality EPDM Rubber
Hosepipe etc., complete

Page No. 346


40.28 Providing 4Kg Fire Extinugisher Clean Agent FE36, Dupont
Providing 4Kg Stored Pressure Type, Pressure Gauge, Gross Weight
6.9kg. empty weight 2.9 kg Can Height 440MM, Diameter 140 MM,
Discharge Time minimum 13 Secs, Controlable discharge mechanism,
Range minimum 4 Meters, applicable on Class A,B,C and electrically
started Fire A, Rating 1A, B, Ranting 13B, Can Construction; Deep
drawn & CO, Mig welded, Valve Construction: Forging & Machining, each 45649.00
Internal Coating of Can : Epoxy Powder coating, External Coating of
Can : Epoxy Polyster Powder coating, Sheet metal thickness: 1.60MM,
Helium Leak Detection Tested, 5 Years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.29 Providing 6Kg Fire Extinugisher Clean Agent FE36, Zeri ODP
Providing 6Kg Stored Pressure Type, Pressure Gauge, Gross Weight
9.4kg. empty weight 3.4 kg Can Height 480MM, Diameter 160 MM,
Discharge Time minimum 13 Secs, Controlable discharge mechanism,
Range minimum 4 Meters, applicable on Class A,B,C and electrically
started Fire A Rating 5A, B, Ranting 34B, Can Construction; Deep
drawn & CO, Mig welded, Valve Construction: Forging & Machining, each 74469.00
Internal Coating of Can : Epoxy Powder coating, External Coating of
Can : Epoxy Polyster Powder coating, Sheet metal thickness: 1.60MM,
Helium Leak Detection Tested, 5 Years Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.30 Providing 9Kg Fire Extinugisher Clean Agent FE36, Zeri ODP
Providing 9Kg Stored Pressure Type, Pressure Gauge, Gross Weight
13.8kg. empty weight 4.8 kg Can Height 611MM, Diameter 175 MM,
Discharge Time minimum 12 Secs, Controlable discharge mechanism,
Range minimum 4 Meters, applicable on Class A,B,C and electrically
started Fire, Can Construction; Deep drawn & CO, Mig welded, Valve each 49500.00
Construction: Forging & Machining, Internal Coating of Can : Epoxy
Powder coating, External Coating of Can : Epoxy Polyster Powder
coating, Sheet metal thickness: 1.60MM, Helium Leak Detection Tested,
5 Years Warranty

40.31 Providing 5Kg Ceiling Mounted Fire Extinugisher Clean Agent


FE36, Zeri ODP
Providing 5Kg Stored Pressure Type, Pressure Gauge, Gross Weight
7.7kg. empty weight 2.7kg Can Height 267MM, Diameter 230 MM,
Discharge Time less than 8 Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire, each 60499.00
Can Construction; Deep drawn & CO, Mig welded, Valve Construction:
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, 5 Years Warranty

Page No. 347

Page 243 of 350


40.32 Providing 10Kg Ceiling Mounted Fire Extinugisher Clean Agent
FE36, Zeri ODP
Providing 10Kg Stored Pressure Type, Pressure Gauge, Gross Weight
14.8kg. empty weight 4.8kg Can Height 316MM, Diameter 300 MM,
Discharge Time less than 8 Secs,Auto discharge mechanism, on
temperature rise, applicable on Class A,B,C and electrically started Fire, each 60720.00
Can Construction; Deep drawn & CO, Mig welded, Valve Construction:
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 1.60MM, Helium Leak Detection Tested, 5 Years Warranty

40.33 CO2 2Kg Squeeze grip


Providing 2 Kg CO2 Gas Type Fire Extinugisher Squeeze grip type,
used Unused Mechanism, Squeeze Grip, Gross Weight 9.1 Kg. empty
Weight 7.1 Kg. Can Height 595MM Diameter 108MM, Discharge Time
less than 8 Secs, Controllable discharge mechanism, Applicable on
Class B&C Fire, B Rating 8B, Can Construction : Hot spinning/Forging, each 12429.00
Valve Construction : Forging & Machining, Internal Coating of Can :
Not Applicable, External coating of Can : Spray Painting, Sheet metal
thickness : 4.0MM ISI Approved, 1 Year Warranty.with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

40.34 CO2 4.5Kg Squeeze grip


Providing 4.5Kg CO2 Gas Type Fire Extinugisher, Trolley Mounted,
Easy Weight Management used Unused Mechanism, Squeeze Grip,
Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM
Diameter 140MM, Discharge Time less than13 Secs, Controllable
discharge mechanism, Applicable on Class B&C Fire, B Rating 13B,
Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & each 18259.00
Machining, Internal Coating of Can : Not Applicable, External coating
of Can : Spray Painting, Sheet metal thickness : 4.5MM ISI Approved,
1 Year Warranty. with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.35 Providing 4.5Kg CO2 Wheel Type


Providing 4.5Kg CO2 gas valve type Fire Extinugisher, Trolley
Mounted, Easy Weight Management used Unused Mechanism,
Gross Weight 19.1 Kg. empty Weight 14.6 Kg. Can Height 860MM
Diameter 140MM, Discharge Time less than13 Secs, Controllable
discharge mechanism, Applicable on Class B&C Fire, B Rating 13B,
Can Constuction : Hot spinning/Forging, Valve Construction : Forging each 10890.00
& Machining, Internal Coating of Can : Not Applicable, External coating
of Can : Spray Painting, Sheet metal thickness : 4.5MM ISI Approved,
1 Year Warranty.with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.36 Providing 6.5Kg CO2 Wheel Type


Providing 6.5Kg CO2 Gas valve type Fire Extinugisher, Trolley
Mounted, Easy Weight Management used Unused Mechanism,
Gross Weight 30.5 Kg. empty Weight 24.0 Kg. Can Height 1015MMDiameter 140MM,
Discharge Time less than 13 Secs, Controllable
discharge mechanism, Applicable on Class B&C Fire, B Rating 34B,
Can Constuctin : Hot spinning/Forging, Valve Construction : Forging & each 16500.00
Machining, Internal Coating of Can : Not Applicable, External coating
of Can : Spray Painting, Sheet metal thickness : 4.5MM ISI Approved,
1 Year Warranty. with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

Page No. 348

Page 244 of 350


40.37 Providing 22.5Kg CO2 Wheel Type
Providing 22.5Kg CO2 Gas Type Fire Extinugisher, Trolley Mounted,
Easy Weight Management used Unused Mechanism, Gross Weight
93.5 Kg. empty Weight 71.0Kg. Can Height 1333MM Diameter
232MM, Discharge Time less than20 Secs, Controllable discharge
mechanism, Applicable on Class B&C Fire, Can Constuction: each 46200.00
Hot spinning/Forging, Valve Construction : Forging & Machining,
Internal Coating of Can : Not Applicable, External coating of Can
: Spray Painting, Sheet metal thickness : 5.20 MM ISI Approved,
1 Year Warranty. complete

40.38 Providing CO2 Aluminium - 2kg


Providing 2Kg CO2 Gas aluminium body Squeeze grip Fire Extinugisher,
Used Unused Mechanism, Squeeze Grip, Gross Weight 5.16 Kg. empty
Weight 3.16Kg. Can Height 615MM Diameter 111MM, Discharge Time
less than 8 Secs, Controllable discharge mechanism, Applicable on
each 10890.00
Class B&C Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion,
Valve Construction : Forging & Machining, Internal Coating of Can : Not
Applicable, External coating of Can : Spray Painting, Aluminium metal
ISO & PESO Approved, 3 Year Warranty. complete

40.39 Providing CO2 Aluminium - 4.5kg


Providing 4.5Kg CO2 Gas Type aluminium body Squeeze grip Fire
Extinugisher, Trolley Mounted, Easy Weight Management, Used Unused
Mechanism, Squeeze Grip, Gross Weight 11.16Kg. empty Weight
6.66Kg. Can Height 860MM Diameter 140MM, Discharge Time less
than10 Secs, Controllable discharge mechanism, Applicable on Class each 15840.00
B&C Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion,
Valve Construction : Forging & Machining, Internal Coating of Can : Not
Applicable, External coating of Can : Spray Painting, Aluminium metal
ISO & PESO Approved, 3 Year Warranty. complete

40.40 Providing Aqueous Film-Forming Foam - 9 Ltr


Providing 9 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type,
Stored Pressure Type, Pressure Gauge, Gross Weight 15.10kg. empty
weight 6.10kg Can Height 615MM, Diameter 175 MM, Discharge Time
less than 60 Secs, Controllable discharge mechanism (Squeeze grip
with easy snap safety seal), Range minimum 6 Meters, applicable on
Class A,B,C A Rating 13A, B Rating 55B, Can Construction; Deep each 8139.00
drawn & CO, Mig welded, Valve Construction: Forging & Machining,
Internal Coating of Can : Epoxy Powder coating, External Coating of Can :
Epoxy Polyster Powder coating, Sheet metal thickness: 2.0MM, ISI and EN Approved,
Helium Leak Detection Tested, 1 Years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 349


40.41 Providing Aqueous Film-Forming Foam - 50 Ltr
Providing 50 Ltr Fire Extinugisher Aqueous Film-Forming Foam Type,
External Cartridge Type, Pressure Gauge, Gross Weight 102kg. empty
weight 52kg Can Height 1192MM, Diameter 300 MM, Discharge Time
less than 180 Secs, Controllable discharge mechanism (Squeeze grip
with easy snap safety seal), Range minimum 10 Meters, applicable on
Class A,B,Can Construction; Deep drawn & CO2, Mig welded, Valve each 29700.00
Construction: Forging & Machining, Internal Coating of Can : Epoxy
Powder coating, External Coating of Can : Epoxy Polyster Powder
coating, Sheet metal thickness: 4.0MM, 1 Years Warranty with instalert
system with Superior quality EPDM Rubber Hosepipe etc., complete

Page 245 of 350


40.42 Providing Water - 9 Ltr - Stored Pressure
Providing 9 Ltr Water type Fire Extinugisher, Stored Pressure Type,
Pressur Gauge, Gross Weight 15.1kg. empty weight 6.1kg Can Height
615MM, Diameter 175 MM, Discharge Time less than 120 Secs,
Controllable discharge mechanism (Squeeze grip with easy snap safety
seal), Range minimum 6 Meters, applicable on Class A Fire, A Rating 3A,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction: each 7699.00
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 2.0MM, ISI and EN Approved, Helium Leak Detection Tested,
1 Years Warranty with instalert system with Superior quality EPDM
Rubber Hosepipe etc., complete

40.43 Providing Water - 50 Ltr


Providing 50 Ltr Fire Extinugisher Water Type, External Cartidge,
Pressure Gauge, Gross Weight 108kg. empty weight 58kg Can Height
1200MM, Diameter 300 MM, Discharge Time less than 180 Secs,
Controllable discharge mechanism (Squeeze grip with easy snap
safety seal), Range minimum 10 Meters, applicable on Class A Fire,
Can Construction; Deep drawn & CO, Mig welded, Valve Construction: each 26400.00
Forging & Machining, Internal Coating of Can : Epoxy Powder coating,
External Coating of Can : Epoxy Polyster Powder coating, Sheet metal
thickness: 4.0MM, 1 Years Warranty with instalert system with Superior
quality EPDM Rubber Hosepipe etc., complete

40.44 Providing Hydro Pyroquell Sytem - 2ltr


Providing 2 Ltr Hydro Pyroquell Sytem Watermist technology base,
Stored pressure type, Rating -15F, Solid stainless body to withstand
hight temperatures, Tamper-proof safety seal, Effective on Class-A,
Class-B, Class-F and Electrically Started Fires, Built-in pressure
gauge, Instalert, Uses distilled water, Gross Weight 4.60 Kg, empty
Weight 2.60kg, can Height 440mm Diameter 140MM, Controllable each 23539.00
discharge mechanism (Squeeze grip with easy snap safety seal), Can
Construction : Deep drawn & CO2 Mig welded, Valve Construction
: Forgin & Machining, ERDA approved, Sheet metal thickness : 1.50MM, Helium Leak
Detection Tested, Discharge Time : Min. 8 Sec.,
5 Year Warranty complete

Page No. 350


40.45 Providing Hydro Pyroquell Sytem - 3ltr
Providing 3 Ltr Hydro Pyroquell Sytem Watermist technology base,
Stored pressure type, Rating -5A. 21B & 25F, Solid stainless body
to withstand hight temperatures, Tamper-proof safety seal, Effective
on Class-A, Class-B, Class-F and Electrically Started Fires, Built-in
pressure gauge, Instalert, Uses distilled water, Gross Weight 6.23 Kg,
empty Weight 3.23kg, can Height 480mm Diameter 160MM, Controllable each 28159.00
discharge mechanism (Squeeze grip with easy snap safety seal), Can
Construction : Deep drawn & CO2 Mig welded, Valve Construction
: Forgin & Machining, ERDA approved, Sheet metal thickness :
1.50MM, Helium Leak Detection Tested, Discharge Time : Min. 13 Sec.,
5 Year Warranty complete

Page 246 of 350


40.46 Providing Hydro Pyroquell Sytem - 6ltr
Providing 6 Ltr Hydro Pyroquell Sytem Watermist technology base,
Stored pressure type, Rating -8A. 34B & 40F, Solid stainless body
to withstand hight temperatures, Tamper-proof safety seal, Effective
on Class-A, Class-B, Class-F and Electrically Started Fires, Built-in
pressure gauge, Instalert, Uses distilled water, Gross Weight 10.4 Kg,
empty Weight 4.4kg, can Height 615mm Diameter 175MM, Controllable each 37729.00
discharge mechanism (Squeeze grip with easy snap safety seal), Can
Construction : Deep drawn & CO2 Mig welded, Valve Construction
: Forgin & Machining, ERDA approved, Sheet metal thickness :
1.50MM, Helium Leak Detection Tested, Discharge Time : Min. 13 Sec.,
5 Year Warranty complete

40.47 Providing Green mist - 2ltr


Green mist Extinguishers : Providing 2 Ltr Watermist technology base,
Stored pressure type, Rating -15F, Mild steel body, Tamper-proof safety
seal, Effective on Class-A, Class-B, Class-F and Electrically Started
Fires, Built-in pressure gauge, Instalert, Uses distilled water, Gross
Weight 4.55 Kg, empty Weight 2.73kg, can Height 435mm Diameter
140MM, Controllable discharge mechanism (Squeeze grip with easy each 16499.00
snap safety seal), Can Construction : Deep drawn & CO2 Mig welded,
Valve Construction : Forgin & Machining, ERDA approved, Sheet metal
thickness : 1.60MM, Helium Leak Detection Tested, Discharge Time :
Min. 22 Sec., 5 Year Warranty with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete

40.48 Providing Green mist - 3ltr


Green mist Extinguishers : Providing 3 Ltr Watermist technology base,
Stored pressure type, Rating -5A. 21B & 25F, Mild Steel body, Tamperproof
safety seal, Effective on Class-A, Class-B, Class-F and Electrically
Started Fires, Built-in pressure gauge, Instalert, Uses distilled water,
Gross Weight 6.23 Kg, empty Weight 3.23kg, can Height 480mm
Diameter 160MM, Controllable discharge mechanism (Squeeze grip each 14850.00
with easy snap safety seal), Can Construction : Deep drawn & CO2 Mig welded, Valve
Construction : Forgin & Machining, ERDA approved,
Sheet metal thickness : 1.60MM, Helium Leak Detection Tested,
Discharge Time : Min. 13Sec., 5 Year Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

Page No. 351


40.49 Providing Green mist - 6ltr
Green mist Extinguishers : Providing 6 Ltr Watermist technology base,
Stored pressure type, Rating -8A. 34B & 40F, Mild steel body t, Tamperproof
safety seal, Effective on Class-A, Class-B, Class-F and Electrically
Started Fires, Built-in pressure gauge, Instalert, Uses distilled water,
Gross Weight 12.15 Kg, empty Weight 6.15kg, can Height 615mm
Diameter 175MM, Controllable discharge mechanism (Squeeze grip each 28159.00
with easy snap safety seal), Can Construction : Deep drawn & CO2
Mig welded, Valve Construction : Forgin & Machining, ERDA approved,
Sheet metal thickness : 2.00MM, Helium Leak Detection Tested,
Discharge Time : Min. 64 Sec., 5 Year Warranty with instalert system
with Superior quality EPDM Rubber Hosepipe etc., complete

Page 247 of 350


40.50 Providing CQRS 2 Kg - Direct Low Pressue System
Providing CQRS 2 Kg - Direct Low Pressue System - Gross Weight
3.98 Kg, Empty Weight 1.98 Kg, Can Height 333 MM, Diameter
108MM, Can construction : Deep Drawn, Valve Construction : Forging /
Machining, External Construction : Epoxy Powder Coating, Helium Leak
Detection Tested, Sheet Metal Thickness: 1.60MM, 1 Year warranty,
Valve, Nickel Plated, With Intergrated Ball Valve, Integrated position
control for ball valve: open - close, Extinguishing Clean Agent FE 36,
Zero ODP, Stored Pressue, Fitted with Pressue Gauge, Control Panel
having Monitoring LED’s for AC Power, System On, Discharged, Valve each 108900.00
Closed, Valve Open, Pressure Healthy, Strobe Red, Strobe Amber,
OLED Graphic Display 95x16, Battery Backp, 3 Outputs using Potential
Free relay contact, Audio Output using Piezo buzzer, 3 Meter Sensor Tue
UV Resistance with Pressrization of Tube Using Nitrogen Gas, End of
Line Plug 1 Pc, End of Line Adapter 1 Pc, T Connection/Elbow/Straight
Connection 1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc,
Tube Attchment 6 Pc. complete

40.51 Providing CQRS 4 Kg - Direct Low Pressue System


Providing CQRS 4 Kg - Direct Low Pressue System - Gross Weight
7 Kg, Empty Weight 3 Kg, Can Height 413 MM, Diameter 140MM, Can
construction : Deep Drawn, Valve Construction : Forging / Machining,
External Construction : Epoxy Powder Coating, Helium Leak Detection
Tested, Sheet Metal Thickness: 1.60MM, 1 Year warranty, Valve, Nickel
Plated, With Intergrated Ball Valve, Integrated position control for ball
valve: open - close, Extinguishing Clean Agent FE 36, Zero ODP, Stored
Pressue, Fitted with Pressue Gauge, Control Panel having Monitoring
LED’s for AC Power, System On, Discharged, Valve Closed, Valve Open, each 132000.00
Pressure Healthy, Strobe Red, Strobe Amber, OLED Graphic Display
95x16, Battery Backp, 3 Outputs using Potential Free relay contact,
Audio Output using Piezo buzzer, 4 Meter Sensor Tue UV Resistance
with Pressrization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc, End of Line Adapter
1 Pc, T Connection/Elbow/Straight Connection
1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
8Pc. complete

Page No. 352


40.52 Providing CQRS 6 Kg - Direct Low Pressue System
Providing CQRS 6 Kg - Direct Low Pressue System - Gross Weight
9.42 Kg, Empty Weight 3.42 Kg, Can Height 460 MM, Diameter
160MM, Can construction : Deep Drawn, Valve Construction : Forging /
Machining, External Construction : Epoxy Powder Coating, Helium Leak
Detection Tested, Sheet Metal Thickness: 2.00MM, 1 Year warranty,
Valve, Nickel Plated, With Intergrated Ball Valve, Integrated position
control for ball valve: open - close, Extinguishing Clean Agent FE 36,
Zero ODP, Stored Pressue, Fitted with Pressue Gauge, Control Panel
having Monitoring LED’s for AC Power, System On, Discharged, Valve each 151800.00
Closed, Valve Open, Pressure Healthy, Strobe Red, Strobe Amber,
OLED Graphic Display 95x16, Battery Backp, 3 Outputs using Potential
Free relay contact, Audio Output using Piezo buzzer, 5 Meter Sensor Tue
UV Resistance with Pressrization of Tube Using Nitrogen Gas, End of
Line Plug 1 Pc, End of Line Adapter 1 Pc, T Connection/Elbow/Straight
Connection 1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc,
Tube Attchment 10Pc. complete

Page 248 of 350


40.53 Providing CQRS 9 Kg - Direct Low Pressue System
Providing CQRS 9 Kg - Direct Low Pressue System - Gross Weight
14.53 Kg, Empty Wight 5.53Kg, Can Height 590 MM, Diameter
175MM, Can construction : Deep Drawn, Valve Construction : Forging /
Machining, External Construction : Epoxy Powder Coating, Helium Leak
Detection Tested, Sheet Metal Thickness: 2.00MM, 1 Year warranty,
Valve, Nickel Plated, With Intergrated Ball Valve, Integrated position
control for ball valve: open - close, Extinguishing Clean Agent FE 36,
Zero ODP, Stored Pressue, Fitted with Pressue Gauge, Control Panel
having Monitoring LED’s for AC Power, System On, Discharged, Valve each 171600.00
Closed, Valve Open, Pressure Healthy, Strobe Red, Strobe Amber,
OLED Graphic Display 95x16, Battery Backp, 3 Outputs using Potential
Free relay contact, Audio Output using Piezo buzzer, 6 Meter Sensor Tue
UV Resistance with Pressrization of Tube Using Nitrogen Gas, End of
Line Plug 1 Pc, End of Line Adapter 1 Pc, T Connection/Elbow/Straight
Connection 1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc,
Tube Attchment 10Pc. complete

40.54 Providing CQRS 2 Kg - Direct high Pressue System


Providing CQRS 2 Kg - Direct high Pressue System - Gross Weight
8.52 Kg, Empty Weight 6.52 Kg, Can Height 595 MM, Diameter 108MM,
Can construction : Hot Spinning/Heat Treatment, Valve Construction :
Forging / Machining, External Construction : Epoxy Powder Coating,
Sheet Metal Thickness: 3.5MM, 1 Year warranty, Valve, Brass, Cylinder
thread : M10x1, Outlet thread: W21, 8x1/14”, Bursting Disc: 250 bar,
Integrated position control for Valve: activated - not activated, Intergrated
position control for ball valve: open-close, Extinguishing Agent CO2
Control Panel having Monitoring LED’s for AC Power, System on, Discharged, Valve each 99000.00
Closed, Valve Open, Pressure Healthy, Strobe Red,
Strobe Amber, OLED Graphic Display 95x16, Battery Backp, 3 Outputs
using Potential Free relay contact, Audio Output using Piezo buzzer,
3 Meter Sensor Tube UV Resistance with Pressurization of Tube
Using Nitrogen Gas, End of Line Plug 1 Pc, End of Line Adapter 1 Pc,
T Connection/Elbow/Straight Connection 1 Pc, Pressure Switch M 10x1,
Switchpoint 15 bar - 1 Pc, Tube Attchment, 6 Pc. complete

Page No. 353


40.55 Providing CQRS 4.5 Kg - Direct high Pressue System
Providing CQRS 4.5Kg - Direct High Pressue System - Gross Weight
14.73 Kg, Empty Weight 13.23 Kg, Can Height 735 MM, Diameter
139MM, Can construction : Hot Spinning/Heat Treatment, Valve
Construction : Forging / Machining, External Construction : Epoxy
Powder Coating, Sheet Metal Thickness: 4.2MM, 1 Year warranty, Valve,
Brass, Cylinder thread : 25E, Dip tube thread M10x1, Outlet thread:
W21, 8x1/14”, Bursting Disc: 250 bar, Integrated position control for
Valve: activated - not activated, Intergrated position control for ball valve:
open-close, Extinguishing Agent CO2 Control Panel having Monitoring
LED’s for AC Power, System on, Discharged, Valve Closed, Valve Open, each 118800.00
Pressure Healthy, Strobe Red, Strobe Amber, OLED Graphic Display
95x16, Battery Backp, 3 Outputs using Potential Free relay contact,
Audio Output using Piezo buzzer, 3 Meter Sensor Tube UV Resistance
with Pressurization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc,
End of Line Adapter 1 Pc, T Connection/Elbow/Straight Connection
1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
8 Pc. complete

Page 249 of 350


40.56 Providing CQRS 6.5Kg - Direct High Pressue System
Providing CQRS 6.5Kg - Direct High Pressue System - Gross Weight
23.2 Kg, Empty Weight 16.7 Kg, Can Height 980 MM, Diameter
139.7MM, Can construction : Hot Spinning/Heat Treatment, Valve
Construction : Forging / Machining, External Construction : Epoxy
Powder Coating, Sheet Metal Thickness: 4.5MM, 1 Year warranty, Valve,
Brass, Cylinder thread : 25E, Dip tube thread M10x1, Outlet thread:
W21, 8x1/14”, Bursting Disc: 250 bar, Integrated position control for
Valve: activated - not activated, Intergrated position control for ball valve:
open-close, Extinguishing Agent CO2 Control Panel having Monitoring
LED’s for AC Power, System on, Discharged, Valve Closed, Valve Open, each 135300.00
Pressure Healthy, Strobe Red, Strobe Amber, OLED Graphic Display
95x16, Battery Backp, 3 Outputs using Potential Free relay contact,
Audio Output using Piezo buzzer, 3 Meter Sensor Tube UV Resistance
with Pressurization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc,
End of Line Adapter 1 Pc, T Connection/Elbow/Straight Connection
1 Pc, Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
10 Pc. complete

40.57 Providing CQRS 22.5Kg - Direct High Pressue System


Providing CQRS 22.5Kg - Direct High Pressue System - Gross Weight
63.6 Kg, Empty Weight 41.1 Kg, Can Height 1170 MM, Diameter 232MM,
Can construction : Hot Spinning/Heat Treatment, Valve Construction : Forging / Machining,
External Construction : Epoxy Powder Coating,
Sheet Metal Thickness: 4.5MM, 1 Year warranty, Valve, Brass, Cylinder
thread : 25E, Dip tube thread M10x1, Outlet thread: W21, 8x1/14”,
Bursting Disc: 250 bar, Integrated position control for Valve: activated
- not activated, Intergrated position control for ball valve: open-close,
Extinguishing Agent CO2 Control Panel having Monitoring LED’s for AC
Power, System on, Discharged, Valve Closed, Valve Open, Pressure each 171600.00
Healthy, Strobe Red, Strobe Amber, OLED Graphic Display 95x16,
Battery Backp, 3 Outputs using Potential Free relay contact, Audio
Output using Piezo buzzer, 3 Meter Sensor Tube UV Resistance with
Pressurization of Tube Using Nitrogen Gas, End of Line Plug 1 Pc, End
of Line Adapter 1 Pc, T Connection/Elbow/Straight Connection 1 Pc,
Pressure Switch M 10x1, Switchpoint 15 bar - 1 Pc, Tube Attchment
12 Pc. complete

Page No. 354


40.58 Smoke Detection - Wireless
Providing Smoke Detection Control Panel - 28 Wireless Zone,
2 Hardwired Zone, Tamper Altert, passcode protected, RF Jamming
recongnition, diagnition, diagnostic feture for RF signal strength between
panel and each detector, event reporting using PSTN Telephone line,
each 41910.00
dialing upto 4 telephone numbers, event reporting as per users choice,
remote control using telephone line, LCD Screen Display, Intuitive
graphic and audible user interphase, Two Way voice interaction, Battery
Backup stand by time upto 12 hrs. complete

40.59 Smoke Detector


Smoke Detector - Fully Supervised Smoke Detector, Photoelectric
detection technology for superior detection sensitivity, sound and
transmitted alrerts for smoke, tamper and low battery, works on each 4292.00
powercode protocol, easy programming and enrolling to the control
panel, Long life 9 votl alkaline or lithium battery simple ceiling mount
installation with separate installation bracket. complete

40.60 Wireless Repeater


Repeater : The Wireless repeater extends the communication range
of Detectors, by relaying data between receiver and remote wireless each 10890.00
transmitters, Up to 16 auxiliary repeaters can be positioned between
the farthest group of receivers transmitters and the receiver. complete

Page 250 of 350


40.61 Wireless Siren Strobe
External Wireless Siren - a fuly supervised Power Code “outdoor
(IP55) wireless siren and strobe light, Designed for external installation,
Wirefree connection between control panel and siren, Convenient and
rapid no-mess installation, Separate fire alarm signals, 98 db Piezo
siren and high power strobe light, Weather-resistant IP55, Two-way
communication for local & remote diagnostic, Plug-in powr supply, NIMH each 14520.00
rechargeable back up battery, Transmits status, tamper, low battery,
supervisior and AC loss messages to the control panel, Tri-state tamper
switch identifies screw mainpulation removal of cover or prying from
the wall complete

Page No. 355


40.62 Smoke Detector Model
Dual chamber ionization detectors provide a high degree of sensitivity
and reliability, A unique inter-connectivity feature can be used to warn
occupants in adjoining areas, An independent 9 volt power supply and a each 4292.00
low battery warning system ensure that the smoke detectors are always
in working condition, Type - Dual Chamber lonisation, Connectivity -
Wired, Alarm Sound Level - 85dB complete

40.63 External GSM Dialler


Providing the GSM unit enables the system to operate over cellular
net work. Indoor plug-in transformer, 120VAC 60 Hz / 9 VAC Current each 24750.00
Consumption : 40mA approx (idle), < 400mA (transmission), Backup
Battery: Ni-Metal, 7.2V, 1300 mAh complete
40.64 Smoke Detector Model
Proividing Dual Technology Smoke Detectors, Sensor Ionisation and
photo electric, Button for Test/Silence, Remote Control silence/Test uses
mot remote controls to temporarily quiet unwanted alarms and test alarm each 4519.00
function, Intelligent Sensing Technology TM helps reduce the number
of nuisance alarms, 9V Battery complete

40.65 Smoke Detector


Providing Dual Chamber lonisation type Smoke Detectors with Escape each 3406.00
Light, 9V Battery Operated, Test Button complete
40.66 Escape Singage
Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
sqcm 1.50
removing the light source (in minutes) : 60 minutes, Luminescent
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay*
(In Minutes) :3100

40.67 Singages for Walls/Floors


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
sqcm 2.25
removing the light source (in minutes) : 60 minutes, Luminescent
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light Decay*
(In Minutes) :3100

Page 251 of 350


40.68 Panaromic Signage
Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
sqcm 1.50
removing the light source (in minutes) : 60 minutes, Luminescent intensity (milicandelas *
per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) :3100

Page No. 356


40.69 Evacution Plan (Price for 10 + unit)
Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
sqcm 7.15
removing the light source (in minutes) : 60 minutes, Luminescent
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) :3100

40.70 Evacution Plan (Price for less than 10 unit)


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
sqcm 8.60
removing the light source (in minutes) : 60 minutes, Luminescent
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) :3100

40.71 Marking Strips


Providing’s Escape Singage : Photoluminescent rigid plastic,
2 mm thickness, Printed on High Quality glass paint with UV resistance,
5 years warranty, Material Used - Non Radiocactive, non-phosphorous,
non toxic and lead free. Available in different types & sizes, Time after
sqcm 2.15
removing the light source (in minutes) : 60 minutes, Luminescent
intensity (milicandelas * per square meter - mcd/sqm) : 30 mcd/sqm.
Luminescent Intensity greater than 0.32 mcd/sqm, Period of Light
Decay* (In Minutes) : 3100

40.72 Escape Gear


Providing’s Escape Gear, Mild Steel Box size 425mm x 360 mm
140mm, Epoxy power coated to protect it from weathering, Smoke
Hood: Tested to European Standard EN 403 : 1993-S, Known to reduce
Carbon monoxide,propenal (acrolein), hydrogen choloride, hydrogen
cyanide and solid & liquid toxic particles to manageable level for at least each 17820.00
15 minutes, shall withstand temperatures upto 80 Deg. Single Use only,
Fire Blanket : Size : 1.2m x 1.8m, Used to cover any vessel containing
the fire completely, Used to extinuish a clothing fire wrap blanket around
victim

40.73 Supplying, Installing testing & commissioning approved make Centrifugal


pump end suction type coupled to Electric motor of suitable HP, fitted
on a commonbase frame and rated for Fireduty. The quated price shall
aslo include 2 Nos. Pressureguages fitted on suction & delivery sides Nos. 126606.00
of the pump. The pumps shall run on 400/440V 3 ph. 50 Hz electric
supply. Duty of pumps: 1620 Lpm @ 70.0m Head. Control panel shall
be as specified in item no, 87

Page No. 357

Page 252 of 350


40.74 Supplying, Installing testing & commissioning electrically driven jockey
pump of capacity 180.0 Lmpm at 75.0m head with all the necessary
accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440V Nos. 106578.00
AC supply including foundation bolt etc. complete. Control panel shall
be as per item No.87
40.75 Supply installing, testing and commissioning COMMON control panel
for fire fighting system consisting of electrical mortor driven 60 HP
Main fire pump, Jockey pump and 12.5 HP consisting of the following
INCOMING: 1 No. Set of phase indicing lamps with SFU Rate 350A
1 No. set of 400 Amps. TPNE Ai.Bus bars 1 No. 0-400 Amps. Ammeter,
1 No.0-600V voltmeter with phase selector switch, Isolating Switch
400 A OUTGOING for Main Electrical Pump: 1 No. 200 Amps MCB
1 No.S/D starter suitable for 60 HP 1 No. Singel phse preventor suitable
for the pump described above 1 No. set of ON/OFF indicating lamps
1 No. Automanual selector switch OUTGOING for Jockey Pump: 1 No.
50 Amps MCB 1 No. DOL starter suitable for 12.50 HP 1 No. Single
phase preventor suitable for the pump described above 1 No. set of
ON/OFF indicating lamps 1 No. Automanual selector switch ENGINE
CONTROL SECTION NO.1 Diesel Engine for Standby pump: a) Main
switch 2 pole ON/OFF -1 No. b) Batter charger with transpormer with
rectifier reistance DC ammeter, DC voltmeter, T/B selector swith -1 set
c) Indicating lamps for fault communication (Battery charger, supply
ON, Control ON, engine running, low oil pressure, high water pressure
and enginer overspeed) - 6 Nos. Push buttons for starter, stop reset - Unit 210000.00
4 Nos. e) Selector switches (Engine control, mode selctor) - 2 Nos. f)
Auxilary rellays/contractors/timer for dsequience operating for starting
and stopping of the engine -1 g) Hooter for audio alarm (Industrial
type) -1 No. Accessoreis for outgoing supply for the morttors GI SWD
earthing wire for the aove motor Accessories for outgoing supply for
Diesel Enginer: Copper conductor armoured cabe 2.5 sqmm of 12 Core
x 2 runs a) Battery 2 strands b) Enginer ON/OFF 2 strands c) Low oil
pressure 3 strands d) Enginer oversped 2 strands e) Water temperature
2 strands f) Spare 1 strand The cost of control panel shall also include
necessary pressure swithces with necessary cabling & inter-locked with
the panel to enable sequential operation of Pumps. Including terrace
mortor necessary earthing All the components shall be housed in a
common cubical. However, the feed cable for diesel engine driven
pump battery charger shall be taken separately

40.76 Supplying Installing testing and commissioning electrically driven


Terrance pump of capacity 900.0 Lpm at 35.0m Head with all the
necessary accessories viz. Pressure guages etc. operating on 3Ph Nos. 88500.00
50Hz, 400/440V AC supply includng foundation, bolts etc. complete.
Control panel shall be as per spesification 87
40.77 Exacavation in all sorts of soil for laying pipes upto 100mm dia including
forming bottom surface to required level, refilling seleted excavated
earth around the pipe in layers of 150mm thick, watering consolidating cum 245.00
and disposing off the surplus earath within the stie or as directed by
the site engineer etc. complete Depth upto 1.0m
Page No. 358
40.78 Supply installation, testing and commissioning of fire alarm Main panel
Nos. 80000.00
with15 zone indication alaram etc. as required
40.79 Supplying Installing testing and commissioning approved make
Centrifugal pump end suction type couple to Electric mortor of suitable
HP, fitted on a common base frame and rated for Fire duty. including
2 nos. Pressure guages fitted on suction & delivery side of the pump. The Nos. 288000.00
pums shall run on 400/440V, 3ph, 50Hz electric supply, Duty of pumps:
2850 Lpm @ 70.0m Head. Control panel shall be per specification stated
in Item No.87. (Cost of control pannel is not included)

Page 253 of 350


40.80 Supplying, Installing, testing and commisioning of fire hydrant multi stage
pump capable of delivering 2850Lpm @ 70.0m head coupled to water
cooled diesel engine of adequiate HP. It shall be fitted with a radiator
on a common base from with complete ancilalary units such as colling Nos. 550000.00
system, non return Valve, Y strainer, fuel tank of adequate coapcity,
Pressue guage, pressure switch. Control panel shall be per specification
stated in Item No.87. (Cost of control pannel is not included)

40.81 Supplying, Installing, testing and commisioning electrically driven jockey


pump of capacity 180.0 Lpm at 70.0m head with all the necessary
accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400/440
V AC supply incldung foudnation, bolts etc. complete Control panel shall Nos. 82974.00
be per specification stated in Item No.87. (Cost of controle pannel is
not included)

40.82 Supplying, Installing, testing and commissioning approved make


Centrifugal pump end suction type couple to Electric motor of suitable
Hp, fitted on a common base frame and rated for Fire duty. The quoted
price shall aslso include 2 nos. Pressure guages fitted on suction and
delivery side of the pump. The pumps shall run on 400/440V, 3ph, Nos. 326172.00
35-Hz electric supply. Duty of pumps: 2850 Lpm @ 90.0m Head. Control
panel shall be per specification stated in Item No.87. (Cost of control
pannel is not included)

40.83 Supplying Installing testing and commissiong COMMON Control panel


for fire fighting system consiting of electrical motor driven 60HP Main
fire pump, Diesel engine driven pump 60 HP Sprinkler pump 50HP & Nos. 250000.00
Jockey pump 25HP
40.84 Supplying, Installing, testing and commissioning approved make
Centrifugal pump end suction type couple to Electric motor of suitable
Hp, fitted on a common base frame and rated for Fire duty. The quoted
price shall aslso include 2 nos. Pressure guages fitted on suction &
delivery side of the pump. The pumps shall run on 400/440V, 3 ph, Nos. 288000.00
50Hz electric supply. Duty of pums: 1620 Lpm @ 70.0m Head. Control
panel shall be per specification stated in Item No.87. (Cost of control
pannel is not included)

40.85 Supplying, Installing testing and commissioning of fire hydrant multi


stage pump capable of delivering 1620 Lpm @ 70.0m head coupled
to water colled diesel enginer of adequate. HP. It shall be fitted with a
radiator on a common base frame with complete ancillary units such as colling sytem, non
return vialve, Y strainer, fuel tank of adequante Nos. 350000.00
capactiy, Pressure guage, pressure switch etc. complete Control panel
shall be per specification stated in Item No.87. (Cost of control pannel
is not included)

Page No. 359


40.86 Supplying, Installing testing and commissioning electrically driven jockey
pump of capacity 180.0 Lpm at 70.0m. Head with all the necessary
accessories viz. Pressure guages etc., operating on 3Ph 50Hz,
400/440V AC supply including foundatin, bolts etc. complete, Control Nos. 106578.00
panel shall be per specification stated in Item No.87. (Cost of control
pannel is not included)

40.87 FIRE HYDRANT SYSTEM Supplying Installing, testing and commissioning


of 63mm mm dia single headed Gun mental Hydrant Valve with flanged
inlet, stop valve, spindle and cast iron hand wheel. It has a female
instantaneous outlet with Blank Cap and is Hydrostatically tested each 7048.00
to 21 Kgf/cm2 pressure having a flow rate of 900 LPM at 7 Kgf/cm
2 of pressure with blank cap and wheel as per IS 5290 etc. complete
Make : WINCO/NEW Age

Page 254 of 350


40.88 Supplying Installing, testing and commissioning of 63mm mm dia double
headed Gun mental Hydrant Valve with flanged inlet 2Nos, stop valve,
spindle and cast iron hand wheel. It has a 2 Nos female instantaneous
outlet with blank cap and is hydrostatically tested to 21 Kgf/cm2 pressure each 11340.00
having a flow rate of 900 LPM at 7 Kgf/cm2 of pressure confirms to
IS : 2190 with blank cap and wheel as per IS 5290 etc. complete

40.89 Supplying Installing, testing and commissioning of Gun metal AIR


each 2100.00
RELEASE VALVE SIZE OF 25mm dia complete
40.90 Supplying Installing, testing and commissioning of Gun metal Branch
pipe size of 63mm dia x19mm dia as per IS 903 Make: WINCO/NEW each 3000.00
AGE complete
40.91 Supplying Installing, testing and commissioning of Reinforced Rubber
Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded
with one set of male and Female Instantainious Gun metal coupling as each 7046.00
per IS 903 WINCO/NEW AGE complete
40.92 Supplying Installing, testing and commissioning of Hose cabinet
made out of 18 gauge M.S.sheet with double glass door with locing
arrangement and painted with two coats of Fire red Enamel paint at each 4300.00
outer ise of the Box and two coats of white enamel paint at inner side of the
box is to accomodated 2 Nos. of Fire hose box size 20”x24”x10” complete
40.93 Supplying Installing, testing and commissioning of Hose reel cabin
M.S.Pressed reel of 600mm dia swinging type motion which allows a each 4800.00
180° swing and conforms to IS:884/85.
40.94 Supplying Installing, testing and commissioning of 19mm dia 36.50m
length hose with rubber lining smooth bore, reinforced of natural/
synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric each 5200.00
marked with minimum thickness of 1.50mm and to with stand a working
pressure of 10Kgf/sqcm confirms & tested as per IS 444
Page No. 360
40.95 Supplying Installing, testing and commissioning of approved make
15mm dia sprinkler bulb pendent/wall mounted type designed to operate
68 degrees centegrad Make Tyco/HD FIRE complete (Colour code
of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57°COrange, each 500.00
68°C - Red, 79°C - Yellow, 93°C - Green, 141°C - Blue, 182°C
- Mauve, 227/260°C - Black)

40.96.1 Supplying Installing, testing and commissioning of hydraulicallying


operated sprinkler cabit Valve with water meter gong bell and trims as
required, pressure gauges drain Valve, ball Valves check valve, strainer etc.-do-100 mm dia. Unit 800.00
Complete
40.96.2 Supplying Installing, testing and commissioning of hydraulicallying
operated sprinkler cabit Valve with water meter gong bell and trims as
required, pressure gauges drain Valve, ball Valves check valve, strainer etc.-do- 150 mm dia. Unit 1500.00
Complete
40.97.1 Supply, Installation testing and commissioning of approved make heavy
quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 2226.00
work includes two coats of metal primer and two coats of Red enamel
paint etc. -do- 200 mm dia. complete

40.97.2 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 1810.00
work includes two coats of metal primer and two coats of Red enamel
paint etc. -do- 150 mm dia. complete

Page 255 of 350


40.97.3 Supply, Installation testing and commissioning of approved make heavy
quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 1378.00
work includes two coats of metal primer and two coats of Red enamel
paint etc.-do- 100 mm dia. complete

40.97.4 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 1096.00
work includes two coats of metal primer and two coats of Red enamel
paint etc. -do- 80 mm dia. complete

40.97.5 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 969.00
work includes two coats of metal primer and two coats of Red enamel
paint etc.-do- 65 mm dia. complete

40.97.6 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 854.00
work includes two coats of metal primer and two coats of Red enamel
paint etc.-do- 50 mm dia. complete

40.97.7 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 733.00
work includes two coats of metal primer and two coats of Red enamel
paint etc. -do- 40 mm dia. complete

40.97.8 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 692.00
work includes two coats of metal primer and two coats of Red enamel
paint etc. -do- 32 mm dia. complete

40.97.9 Supply, Installation testing and commissioning of approved make heavy


quantity (Class ‘C’) confirming to as per IS1239 Such as Tees elbows
check nuts unions, Flanger, Nipples etc. including cutting welding,
Trending fixing on walls, cealing (Using 41-Tech pipe/M.S.angle supports m 639.00
work includes two coats of metal primer and two coats of Red enamel
paint etc. -do- 25 mm dia. complete

40.98.1 Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth.-do- 200 mm dia. Complete m 360.00

40.98.2 Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth. -do- 150 mm dia. Complete m 250.00

40.98.3 Wraping and Galing of U/G pipe line work includes one coat of anti
corrossion paint (Black) and two coats of Bituminous cloth. -do- 100 mm dia. Complete m 200.00

40.98.4 Wraping and Galing of U/G pipe line work includes one coat of anti
m 150.00
corrossion paint (Black) and two coats of Bituminous cloth. -do- 80 mm dia. Complete
Page No. 361

Page 256 of 350


40.99.1 Supplying Installation testing and Commissiong of Micro precess base
Fire alram Control panel having power regulation Circuit, which conner
to 230 AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with
Feather touch push button switches, Test facility also with work test
facility arrangement, provided in the panel. All this electronic circuits each 18000.00
componets are assembled in M.S.16 gauge suitable panel cabinet with
glass Fraonted and locking arrangements including cost of all mateials
etc. -do- Make Ravel/Golbe/Royale 12 Zone. complete

40.99.2 Supplying Installation testing and Commissiong of Micro precess base


Fire alram Control panel having power regulation Circuit, which conner
to 230 AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with
Feather touch push button switches, Test facility also with work test
facility arrangement, provided in the panel. All this electronic circuits each 24000.00
componets are assembled in M.S.16 gauge suitable panel cabinet with
glass Fraonted and locking arrangements including cost of all mateials
etc. complete

40.99.3 Supplying Installation testing and Commissiong of Micro precess base


Fire alram Control panel having power regulation Circuit, which conner
to 230 AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with
Feather touch push button switches, Test facility also with work test
facility arrangement, provided in the panel. All this electronic circuits each 35000.00
componets are assembled in M.S.16 gauge suitable panel cabinet with
glass Fraonted and locking arrangements including cost of all mateials
etc. -do- Make Ravel/Golbe/Royale 16 Zone. complete

40.99.4 Supplying Installation testing and Commissiong of Micro precess base


Fire alram Control panel having power regulation Circuit, which conner
to 230 AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with
Feather touch push button switches, Test facility also with work test
facility arrangement, provided in the panel. All this electronic circuits each 50000.00
componets are assembled in M.S.16 gauge suitable panel cabinet with
glass Fraonted and locking arrangements including cost of all mateials
etc. -do- Make Ravel/Golbe/Royale 20 Zone. complete

40.99.5 Supplying Installation testing and Commissiong of Micro precess base


Fire alram Control panel having power regulation Circuit, which conner
to 230 AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with
Feather touch push button switches, Test facility also with work test
facility arrangement, provided in the panel. All this electronic circuits each 105000.00
componets are assembled in M.S.16 gauge suitable panel cabinet with
glass Fraonted and locking arrangements including cost of all mateials
etc. -do- Make Ravel/Golbe/Royale 40 Zone. complete

40.99.6 Supplying Installation testing and Commissiong of Micro precess base


Fire alram Control panel having power regulation Circuit, which conner
to 230 AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with
Feather touch push button switches, Test facility also with work test
facility arrangement, provided in the panel. All this electronic circuits each 148000.00
componets are assembled in M.S.16 gauge suitable panel cabinet with
glass Fraonted and locking arrangements including cost of all mateials
etc. -do- Make Ravel/Golbe/Royale 60 Zone. complete

40.99.7 Supplying Installation testing and Commissiong of Micro precess base


Fire alram Control panel having power regulation Circuit, which conner
to 230 AC to @$V.D.C. Indicating FIRE-FAULT, ISOLATION with
Feather touch push button switches, Test facility also with work test
facility arrangement, provided in the panel. All this electronic circuits each 185000.00
componets are assembled in M.S.16 gauge suitable panel cabinet with
glass Fraonted and locking arrangements including cost of all mateials
etc. -do- Make Ravel/Golbe/Royale 76 Zone. complete

Page 257 of 350


40.100 Supplying Installing, testing and commissioning of Smoke/Heat detector
Photo electric type detctor with base LED indicator on Smioke detector
fixed cum rise temperature type heat detector with base Make Applow/ each 3406.00
System Sensor complete
40.101 Supplying Installing, testing and commissioning of Manual Call point :
It consists of Micro push button switch with LED and circutary etc.
works on 24V DC LED indicator with glass Fronted, Also with hammer each 1200.00
for breaking the glass incase of Fire. Accomdated in 75x75x30mm size
M.S.16 gauge red enamel painted box Make/Golbe/Ravel/Royale. complete
40.102 Supplying Installing, testing and commissioning of electronic Hooter,
it conists of electronic circuit to give dual Fire alaram sound with works
24V DC with speaker all encosed in suitable in M.S. 16 gauge red painted each 1800.00
box. Complete
40.103 Supplying Installing, testing and commissioning of Response Indictor
constists of twin LED wioth electronic circutarx work on 24 DC enclose each 300.00
in PVC retangular. Complete
40.104 Supplying and fixing sheet metal box made out of 18 SWG sheet metal
with necessary holes for cable/conduit entry as required with one coat each 96.00
of primer of approved make etc.
40.105 Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade copper with flexible copper conductor confirming
to table 3 class 5 of IS:8130-1984 and PVC insulation and sheathed m 32.00
suitable for working voltage upto 1100Volts as per IS-694:1990 &
confirming to GTP of GROUP-B. 2C x 1.5 SqmmV
40.106 SITC of 7AM-12 V Battery for fire alaram system Make EXIDE/AMCo each 1200.00
40.107 Providing and Fixing Fire force board size of 3’x2’ made out to Acrylic
sheet of 3mm thick with letter of different Colums with 8mm thick ply each 2950.00
wood, Alumimum side frame and fixing etc. Complete
40.108 Supplying Installing, testing and commissioning of Public address system
(Two way comminication type) as per requirement of Fire Force authority
and which Generally comprise of Supplying Installing, testing and each 2300.00
commissioning of Approved make 5 W.wall mounted speaker with talk
back facility with store enamel painted M.S.Sheet hosing etc. complete
Page No. 362
40.109. Supplying Installing, testing and commissioning of P.A.System console
1 panel with push button with speaker and indictoron Accomdated in each 48000.00
M.S.Cabinet with painting -do- 20 Zone cansole. Complete
40.109. Supplying Installing, testing and commissioning of P.A.System console
2 panel with push button with speaker and indictoron Accomdated in each 95000.00
M.S.Cabinet with painting -do- 40 Zone cansole. Complete
40.109. Supplying Installing, testing and commissioning of P.A.System console
3 panel with push button with speaker and indictoron Accomdated in each 125000.00
M.S.Cabinet with painting -do- 60 Zone cansole. Complete
40.110 P.A.System amplifier 250W RMS out put with complete wiring and
each 32000.00
controls accessable form front Make AHUJA. Complete
40.111 Supplying Installing, testing and commissioning of Ahuja make MIKE
each 1500.00
suitable to I.A.System. Complete
40.112 Supplying and drawing Flexible Multicore Cable manufactured with
electrolytic grade flexible copper with low conductor confirming to table
3 class 5 of IS:8130-1984 and (Virgin) PVC insulation and sheathed m 37.00
suitable for working voltage upto 1100Volts as per IS-694:1990 &
confirming to GTP of GROUP-A. 2C x 1.50 Sqmm
40.113 Supplying of four bucket stand alongwith buckets. Complete each 1200.00
40.114 Supplying of two bucket stand alongwith buckets. Complete each 630.00
40.115 Supplying of Hand gloves. Complete pair 170.00
40.116 Supplying of first aid box. Complete each 215.00
40.117 Supplying of SAFETY MASK. Complete each 64.00
40.118 Supplying of FIRST AID CHART with lamination. Complete each 225.00

Page 258 of 350


40.119 Supplying and installation of RUBBER MAT 1mtr x 1mtr -10mm thick.
Nos. 1105.00
Complete
40.120. Supply, Installation testing and commissioning of approved make heavy
1 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 2886.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
200 mm dia. complete

40.120. Supply, Installation testing and commissioning of approved make heavy


2 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts m 2140.00
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes-do- Galvanized
Iron Pipes 150 mm dia. complete
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
150 mm dia. complete

40.120. Supply, Installation testing and commissioning of approved make heavy


3 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 1566.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
100 mm dia. complete

40.120. Supply, Installation testing and commissioning of approved make heavy


4 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 1231.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
80 mm dia. complete

Page 259 of 350


40.120. Supply, Installation testing and commissioning of approved make heavy
5 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 1076.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
65 mm dia. complete

40.120. Supply, Installation testing and commissioning of approved make heavy


6 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 941.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
50 mm dia. complete

40.120. Supply, Installation testing and commissioning of approved make heavy


7 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 809.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
40 mm dia. complete

40.120. Supply, Installation testing and commissioning of approved make heavy


8 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 756.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
32 mm dia. complete

Page 260 of 350


40.120. Supply, Installation testing and commissioning of approved make heavy
9 tubes (Class ‘C’) confirming to as per IS1239 Part - I (25mm Nominal
bore 4.05mm thick @ 2.97 Kg/m, 32mm Nominal bore 4.05mm thick
@ 3.84 Kg/m,40mm Nominal bore 4.05mm thick @ 4.43 Kg/m,50mm
Nominal bore 4.47mm thick @ 6.17 Kg/m, 65mm Nominal bore 4.47mm
thick @ 7.90 Kg/m, 80mm Nominal bore 4.85mm thick @ 10.10 Kg/m,
100mm Nominal bore5.40mm thick @ 14.40 Kg/m,150mm Nominal m 687.00
bore 5.40mm thick @ 21.20 Kg/m, Such as Tees elbows check nuts
unions, Flanger, Nipples etc. including cutting welding, Trending fixing
on walls, ceiling (Using 41-Tech pipe/M.S.angle supports work includes
two coats of metal primer and two coats of Red enamel paint etc.-do- Galvanized Iron Pipes
25 mm dia. complete

Page No. 363

41.0 ENERGY CONSERVATION BUILDING CODE


41.1
41.2
41.2.1
41.2.2
41.3
41.3.1
41.3.2
41.3.3
41.3.4
41.4
41.4.1
41.4.2
41.5
41.5.1
41.5.2
41.5.3
41.6
41.6.1
41.6.2
41.6.3
41.6.4
41.6.5
41.6.6
41.7
41.7.1
41.7.2
41.7.3
41.8
41.8.1
41.8.2
41.8.3
41.8.4
47.9
47.9.1
47.9.2
47.9.3
47.9.4
41.10
41.10.1
41.10.2
41.10.3
41.10.4
41.10.5
41.11.1

Page 261 of 350


41.11.2
41.11.3
41.11.4
41.11.5
41.12
41.12.1
41.12.2
41.12.3
41.12.4
41.12.5
41.13
41.13.1
41.13.2
41.13.3
41.13.4
41.14
41.14.1
41.14.2
41.14.3
41.14.4
41.14.5
41.14.6
41.15
41.15.1
41.15.2
41.16
41.16.1
41.16.2
41.16.3
41.16.4
41.16.5
41.16.6

Page 262 of 350


Sl Number Name Unit Rate in Rs.
0009 Adhesive(for linoiling flooring) Kg 180.00
0509 Adhesive for tiles Kg 22.00
0514 Adhesive for joints Kg 62.00
0022 Bees Wax Kg 148.00
0513 High bond tile adhesive for vitrified tiles Kg 18.00
2008 Kgs 170.00
2047 Ball Adhesives Kgs 205.00
0387 Shellac Kgs 210.00
0054 Brick bats 25 to 100 mm Cum 600.00
0055 Brick aggregate 20 mm(Nominal) Cum 600.00
0056 Brick aggregate 25 mm(Nominal) Cum 600.00
0064 100 Nos. 610.00
Burnt brick class designation 35 ( Non Modular) Ground Moulded
0503 Burnt brick class designation 35 (modular) 100 Nos. 550.00
0488 Table moulded bricks class designation 50 (non modular) 100 Nos. 700.00
0504 Table moulded class designation 50 (modular) 100 Nos. 700.00
0505 Wire cut bricks of class designation 75 (non modular) 100 Nos. 1325.00
0506 Wire cut bricks of class designation 75 ( modular) 100 Nos. 1200.00
0311 100 Nos. 3800.00
0391 Solid blocks (concrete 40x20x20cms) 100 Nos. 4450.00
0501 100 Nos. 2800.00
0502 100 Nos. 3100.00
0497 100 Nos. 4700.00
0498 Hollow concrete blocks (40x20x15cms) 100 Nos. 4000.00
0499 100 Nos. 2100.00
2109 Pre-cast clay hollow bricks 40cm x 20cm x 20cm Each 47.00
2110 Each 35.00
Each
2111 28.00
0175 100 mm and down nominal size Cum 675.00
0734 53 mm nominal size Cum 750.00
0750 40 mm nominal size Cum 825.00
0060 30 mm nominal size Cum 825.00
0800 25 mm nominal size Cum 975.00
0749 20 mm nominal size Cum 1050.00
0058 12.5 mm nominal size Cum 950.00
0057 10 mm nominal size Cum 950.00
0707 6 mm nominal size Cum 750.00
0803 Fine aggregate 2.36 mm nominal size Cum 750.00
0762 Key aggregates 22.4 to 2.8 mm Cum 975.00
0746 Filter media stone aggregate Cum 600.00
0904 Coarse aggregates 53 mm Cum 750.00
0906 Crushed aggregates 37.5mm Cum 825.00
0912 Crushed coarse aggregate (Supply of hand broken aggregates) Cum 700.00
0919 Cum 975.00
0921 Crushed stone aggregate 13.2mm to 10mm Cum 925.00
0922 Cum 975.00
0926 Crushed aggregate 9.5mm to 4.75mm Cum 750.00
567 Tonne 1100.00
0732 Crushed stone chippings 11.2 mm Cum 950.00
0733 Crushed stone chippings 13.2 mm Cum 950.00
0400 Stone dust / Grit Cum 750.00
0815 Crushed stone chipping 5.6 mm size cum 750.00
0819 Lime Stone Dust Tonne 6000.00
0287 Pea size gravel/6mm and down stone grit cum 350.00
0334 Sand/ Artificial Sand/ Manufactured Sand cum 1700.00
0551 Ordinary earth cum 120.00
0731 Sand / Crushed Sand cum 1700.00
0751 Granular material cum 160.00
0752 Gravel 2.36 mm cum 160.00
0772 Natural sand 5.6 to 75 micron cum 1700.00
0781 Quartz sand Kgs 400.00
0037 Bond stones 20cms x 20cms x 45cms Each 22.00
0039 Boulders Cum 600.00
0066 Burnt stone slabs 10cms thick Sqm 400.00
0174 Granite stone slabs fine dressed 40 mm thic Sqm 1600.00
0330 Rubble stones Cum 400.00
0390 Size stone 20x20x25 cm Each 11.00
0401 Stone slab 10 to 12 cm thick Sqm 500.00
0720 Bond stone 20x20x45 cm Each 22.00
0780 Quarry spalls Cum 250.00
0789 Size stone 20x20x25 cms Each 11.00
0790 Spall (jelly used for packing) Cum 400.00
0793 Rough stones Cum 300.00
0794 Stone boulders Cum 600.00
0795 Stone spalls Cum 300.00
0939 Stone with minimum size of 200mm Cum 600.00
0010 Aluminium beading Kgs 132.00
0011 Aluminium handles - 15mm Each 58.00
0012 Aluminium hinges 75 mm length Each 38.00
0013 Aluminium stays Each 39.00
0014 Aluminium tower bolt - 20 cm Each 75.00
0017 Aluminium sheet for strips Sqm 280.00
0018 Aluminium window frame section 1.2 mm thick Kgs 172.00
0522 Aluminium Composite panel of approved colour straight portion Sqm 3200.00
0533 Aluminium frame section Kgs 195.00
0544 Aluminium composite panel of curved portion Sqm 3600.00
0860 Aluminium studs 100 x 100mm fitted with lense reflectors nos 230.00
Aluminium sheeting fixed with encapsulated lens type reflective
0942 3775.00
sheeting of size 0.9sqm Sqm
Aluminium alloy/galvanised steel/ Galvanised MS plate including
0943 52900.00
5% wastage Tonne
Aluminium alloy plate, 2mm thick, fixed with high intensity grade
0944 3775.00
sheeting vide Clause 801.3 Sqm
2069 Alluminium anodised profile top cap beading m 345.00
0007 AC sheet 6 mm thick semi corrugated Sqm 165.00
0008 AC sheet 6 mm thick semi trafford Sqm 190.00
0327 Ridges (AC sheet) Pair 201.00
0717 Bitumen 80/100 Grade bulk Tonne 40866.00
835 Bitumen 80/100 Packed Tonne 44907.00
0814 Bitumen 60/70 Grade Tonne 41877.00
836 Bitumen 60/70 Packed Tonne 45918.00
0030 Bitumen 85/25 Grade Tonne 40866.00
0820 Bitumen 30/40 Grade Tonne 40866.00
0730 CRMB Tonne 51671.00
0806 NRMB 70 Tonne 73810.00
0735 Cut back MC 70 Tonne 71927.00
0718 Bitumen emultion Tonne 40096.00
0031 Bitumen felt (hersian based) Sqm 85.00
0032 Bitumen washer Each 1.00
0109 Coal tar Sqm 15.00
0108 Coal tar paint L 30.00
0035 Blown or residual bitumen Tonne 40866.00
0807 Polymer MB 70 Tonne 73810.00
0736 Detonator Each 8.00
0738 Drill bits Nos 375.00
0786 Safety fuse wire Coil 200.00
0791 Gelatin Kg 110.00
0002 12 mm thick pre laminated board (Novapan) exterior grade Sqm 582.00
Prelaminated board 19 mm thick of approved lamination on both
0312 672.00
side Sqm
Prelaminated board of approved lamination on one side and
0313 582.00
balancing white colour Sqm
0301.a a.Plywood 12 mm thick (Commercial) Sqm 875.00
0301.b b.Plywood 19 mm thick (Commercial) Sqm 1000.00
0301.c c.Plywood 25 mm thick (Commercial) Sqm 1700.00
0301.d d.Sheet 6 mm thick (Commercial) Sqm 600.00
0293 Plain particle board Sqm 450.00
0180 Hard board 45 x 45 mm size Sqm 120.00
0181 Hard board 600 x 450 mm size Sqm 138.00
0955 Pre-moulded asphalt filler board Sqm 600.00
2006 12mm plywood Sqm 720.00
2007 4mm thick veneer Sqm 1080.00
2009 19mm Plyboards Sqm 1050.00
2010 1.5mm Laminate Sqm 780.00
2090 5mm PVC sheet Sqm 745.00
2099 5mm BS prelam PVC sheet Sqm 1004.00
2100 5mm SS prelam PVC shee Sqm 873.00
2101 2mm PVC sheet Sqm 345.00
0084 Cement Kg 670.00
0439 White cement Kg 1800.00
1557 Kg 620.00
Portland Slag Cement (PSC)/ Portland Pozzolona Cement (PPC)
1558 Ground Granulated blast furnace slag(GGBS) Kg 340.00
0088 Chequered mosaic tiles grey Sqm 250.00
0089 Chequered mosaic tiles light shade Sqm 300.00
0090 Chequered mosaic tiles medium shade Sqm 275.00
0091 Chequered mosaic tiles white colour Sqm 350.00
0110 Cobble stone 60 mm thick Sqm 400.00
0111 Cobble stone 75 mm thick Sqm 458.00
0116 Cuddapah slab 2.5 cm to 4 cm thick Sqm 286.00
0176 Gray colour mosaic tiles Sqm 225.00
0213 Light shade mosaic tiles Sqm 225.00
0228 Machine cut granite stone slab 40 mm Sqm 900.00
0229 machine polished granite stone slab 20 mm Sqm 600.00
0231 marble chips Kgs 20.00
0234 Marble dust Cum 858.00
0235 marble powder Cum 725.00
0237 marble slab 20 mm thick Sqm 1200.00
0248 metallic floor hardner Kgs 550.00
0386 shahabad slabs 2.5 cm to 4 cm thick Sqm 343.00
0448 white mosaic tiles Sqm 175.00
0507 vitrified tiles 10 mm thick 600X600 mm granolite finish Sqm 612.00
0508 vitrified tiles 600X600 mm 10 mm thick Sqm 544.00
0545 20 mm thick hassan green granite Sqm 1500.00
0546 ceramic tiles 30X30 cms Sqm 435.00
0510 Grout for vetrified tiles Kgs 91.00
0511 Spacers for Vetrified tiles No 1.50
0512 Sealer for vetrified tiles Sqm 1.70
0515 Prepolished Grey granite 20 mm thick Sqm 1400.00
0517 20 mm thick Ruby red granite Sqm 1800.00
0518 20 mm thick grey granite Sqm 973.00
0519 20 mm thick Shiva gold granite Sqm 2100.00
0520 20 mm thick Black granite Sqm 1200.00
0521 Prepolished black granite 20 mm thick Sqm 1400.00
0523 Prepolished Water cut grey granite Sqm 1030.00
0725 Chequerred cement concrete tiles Sqm 207.00
0416 Tandur blue slabes 2.5cms to 4 cm thick Sqm 286.00
0545 20mm thick Hassan green granite Sqm 1500.00
2076 Lakared granite Sqm 2500.00
2085 Sadarahalli flammed granite 40mm Sqm 1100.00
2086 Sadarahalli pre polished granite 20mm Sqm 950.00
2108 Black granite 40mm thick Sqm 2100.00
0112 Colour glazed tiles 15 x 15 cms 10mm thick Each 7.00
0113 White glazed tiles 15 x 15 cms 6mm thick Each 5.50
0186 Hersian cloth for using in tiles as reinforcement sqm 40.00
0217 Linolium sheet for tile 30 cmsx30cms sqm 250.00
0464 Yelahanka tiles of size 250x250 mm Each 4.00
0481 Mangalore tiles first class and special tile for ridges and hips nos 13.00
0485 Medium shade mosaic tiles sqm 100.00
0486 Ceramic tiles 15 cms x 15 cms sqm 250.00
0444 White glazed tiles 15 cms x 15 cm , 10 mm thick plain Each 6.50
0445 Color glazed tiles 15 cm x 15 cm, 10 mm thick anti skid Each 6.70
578 Pre polished grey granite tile 10mm sqm 500.00
579 Pre polished black granite tile 10mm sqm 1000.00
2073 Concrete designer tiles sqm 485.00
2074 Ceramic tiles of 300x 600mm sqm 450.00
2075 Ceramic tiles of 300x 450mm sqm 350.00
2042 Border tiles 30x10cms Each 125.00
2043 Glazed tiles 300 x 450 sqm 270.00
2026 Ceramic tiles 400 x 400mm sqm 400.00
0495 Ready Mix Concrete M 20 (1:1.5:3) cum 4600.00
0496 Ready Mix Concrete M 25 (1:1:2) cum 4800.00
2200 Ready Mix Concrete M 30 cum 4900.00
2201 Ready Mix Concrete M 35 cum 5100.00
2202 Ready Mix Concrete M 40 cum 5300.00
0003 18 gauge 75 mm MS laths of 2.8 m length Nos 200.00
0004 Z section Kgs 45.00
0019 Angle iron 40x40x6mm Kgs 45.00
0087 Channels 25x25x6 mm Kgs 45.00
0187 High tension coil oxidised MS Each 650.00
0203 Hooks oxidised MS 150 mm Each 15.50
0221 M.S. flat 30 cmx25mmx3mm Kgs 45.00
0223 M.S. Round Bright bars 20mm Q 5200.00
0224 M.S. Square Bright bars 20mm Q 5200.00
0249 Mild steel 6 mm dia Kgs 41.00
0250 Mild steel bars Q 4100.00
0252 MS channels Kgs 45.00
0255 MS flats 20 mm x 6 mm Kgs 45.00
0257 MS plates Kgs 48.00
0258 MS rods Kgs 41.00
0259 MS sheet 1 mm thick Kgs 48.00
0260 MS sheet 20 gauge Kgs 48.00
0262 MS tees Kgs 45.00
0264 Mullion section (MS) Kgs 45.00
0288 Pig lead Kgs 50.00
0414 T section MS Kgs 45.00
0484 M.S.Shoes Kgs 45.00
0547 Expanded metal 12.5 mm to 25 mm -14 G sqm 280.00
0714 Bearing plates Tonne 60500.00
0716 Binding wire Kgs 60.00
0723 Cast Steel Kgs 51.00
0724 Cast Steel rocker assembly Kgs 83.00
0739 Edge beams of steel of special shape and section Kgs 58.00
0748 Forges Steel (2 rollers) Kgs 230.00
0756 High Tensile steel wires/strands Tonne 52000.00
0757 High Tensile strands q 5200.00
0758 Thermo Mechanically Treated bars (TMT bars) Tonne 44500.00
0759 ISMC 1002.806x1.05 Tonne 50000.00
0763 Mild steel q 4100.00
0764 Mild steel anchors Kgs 41.00
0765 Mild steel matrix including wastage Kgs 43.00
0766 Mild steel plate(Galvanised) Tonne 50000.00
0767 MS bars Tonne 50000.00
0770 MS flats Tonne 50000.00
0771 Ms gratings 260 mmx 260 mm Each 89.00
0777 Pile shoes-Ci Kgs 89.00
0778 Pile shoes-MS Kgs 50.00
0792 Stainless steel 304 grade Kgs 288.00
0862 Mild Steel pipe 100mm dia 2.5mm thick m 264.00
0863 Mild Steel pipe 25mm dia 2.5mm thick m 90.00
0864 CGI sheets Kgs 40.00
0865 Angle iron 45x45x5mm Kgs. 45.00
0866 M.S sheet 300mm wide,2.5mm long and 2.6mm thick Kgs. 48.00
0867 Angle iron 50x50x2mm long Kgs. 45.00
0868 M.S sheet of 12 SWG, 3 Nos of 200mm width and 4m length Kgs. 48.00
0870 Steel drum 300mm dia 1.2m high/empty Nos. 111.00
0940 Kgs. 45.00
0941 Kgs. 45.00
Corrugated sheet, 3mm thicken "W" beam section railing, 4.5m in
0957 Kgs. 55.00
length.
0958 Channel post 150 x 75 x 5mm Kgs. 45.00
0959 Channel 150 x 75 x 5 mm Kgs. 45.00
Structural steel in plates, angles, Galvanised structural steel plate
0963 45000.00
etc.,including 5% wastage Tonne
0972 RS joist 100 x 75mm Kgs. 45.00
0973 Struts - 2 Nos. for terminal posts, 2m long each 2 x 2 x 11.50 Kgs. 45.00
Tie 2 Nos. of 8mm steel plate, 1.5sqm each for terminal posts at
0974 45.00
62.80kg/sqm(2x1.5) Kgs.
0975 Steel wire rope 40mm Kgs. 45.00
0976 Mild steel pipe 25mm dia, 2.5mm thick m 90.00
MS sheet for 600 x 300 x3mm rectangular vane, one number at 24
0977 48.00
kg/sqm Kgs.
MS sheet for 250mm dia circular vane 3mm thick, 4 number at 24
0978 48.00
kg/sqm Kgs.
0979 MS sheet 3mm thick at 24kg/sqm Kgs. 48.00
Galvanised angle sections 100mm x 10mm of 12mm thickness
0981 weldable structural steel as per IS:2062.2 Nos. of 12m length 48.00
each at 17.7 kg/m Kgs.
0988 Helical pipes 600mm diametre m 166.00
0989 Tie rodes 20mm diametre Kgs. 48.00
Steel circular hollow pole of standard specification for street
1100 7700.00
lighting to mount light at 9m height above road level. Each
Tube anchorage set complete with bearing plate, permanent
1510 No. 12690.00
wedges etc.
1512 Bearing No. 0.55
1513 Bearing rocker & Roller No. 4400.00
1516 Sheating duct ID 66mm Tonne 57200.00
1519 32mm mild steel dowel bars of grade s240 Tonne 54637.00
1520 16mm deformed steel tie bars fo grade S 415 Tonne 54637.00
1534 20 x 5 mm diaganals Kgs. 48.00
Cast steel rocker bearing assembly of 250 tonne design load
1553 capacity duly painter complete with all leads components as per 78490.00
drawing and specifications Nos.
PTFE sliding plate bearing assembly of 80 t. design load capacity
1554 duly painted complete with all its components as per drawing & 78490.00
technical specification. Nos.
558 MS angles 65 X 65 X 6 mm 34.7 Kgs Kgs. 45.00
562 38 mm dia of 14 guage MS black pipe m 50.00
561 20 mm dia hold fast Rod Nos. 58.00
571 Stainless steel strips m 211.00
573 M S Clamps for Shoe Kgs. 54.00
576 Steel column 400x250 mm (ISHB Series) Tonne 55000.00
577 Forged steel rollar bearing of 250 tonne No. 3349.00
Steel circular Hollow pole of standard specification for street
1103 each 4950.00
lighting to mount light at 5m height above road level.
2022 MS flat 12x75mm Kgs 43.00
2021 M S Tubes Kgs 60.00
2027 50mm dia M.S. Hollow pipe B Class 14 Gauge Kgs 60.00
2028 20mm x 20mm vertical M.S. Square Rod Kgs 52.00
2015 Gusset plates 6mm thick Kgs 59.00
2016 Base plate/ base plate Kgs 59.00
2018 Anchor Bolts 750mm No. 127.00
2029 12x12 M.S. Square Rod Kgs 52.00
2030 16x16mm M.S. Square Rod Kgs 52.00
2031 40x6mm M.S. Flat Kgs 48.00
2032 12mmx6mm M.S. Flat Kgs 48.00
2033 Cast iron spike Nos. 88.00
2034 50x50 M.S. Hollow pipe Kgs 60.00
2036 36mm x 6mm M.S. Flat Kgs 48.00
2038 Kgs 294.00
2039 Kgs 294.00
2040 5" dia 5mm thick M.S. plate Nos. 48.00
2067 MS pipes of 80mm to 100mm dia Kgs 48.00
2068 RMS Gusset plate Kgs 55.00
2078 Stainless steel tubes 40mm, 14 gauge Kgs 281.00
2091 M.S. Tube m 264.00
489 M.S. 20mm Square bar q 52000.00
MS angle iron 40mm x 40mm x 6mm, 23 metre in length at 3.5 kg
0949 Kgs 45.00
pe metre
MS angle iron 50mm x 50mm x 6mm, 33.8 metre in length at 4.5
0950 Kgs 45.00
kg per metre.
0951 Runner flat 50 x 5mm Kgs 45.00
Welded steel with fabric 75 x 50mm mesh at 4kg/ sqm, 4 x 30 x
0952 Kgs 46.00
1.2+5% wastage
0953 Steel pipe 50mm external dia as per IS:1239 2.5mm thick m 176.00
Medium wt. steel channel (ISMC Series) 100mm x 50mm,10.8
0954 Kgs 45.00
metre length at 9.2 kg per m
0115 Corner beads 45x45 mm m 15.00
0190 honne wood Cum 70000.00
0191 honne wood beading 10 mm wide m 15.00
0193 honne wood beading 20x20 mm m 21.00
0194 Honne wood scantling Cum 70000.00
0195 Honne wood scantling for styles and rails 30mm thick Cum 70000.00
0196 Honne wood scantling for styles and rails 35mm thick Cum 70000.00
0198 Honne wood planks for shutters(frame) 35mm thick cum 76000.00
0200 Honne wood planks for panels 20mm thick cum 76000.00
0201 Honne wood battens cum 71000.00
0202 Honne wood beads cum 71000.00
0205 Jungle wood battens 25mm x 40mm cum 34000.00
0206 Jungle wood battens 50mm x 40mm cum 34000.00
0207 Jungle wood runners and planks cum 34000.00
0208 Jungle wood runners and planks cum 34000.00
0209 Jungle wood scantling cum 34000.00
0238 mathi or Nandi wood cum 58000.00
0239 mathi or Nandi wood planks for panels 20mm thick cum 58000.00
0240 mathi or Nandi wood scantlings for styles and rail 25mm thick cum 58000.00
0241 mathi/Nandi wood cum 58000.00
0242 mathi/Nandi wood battens cum 56000.00
0243 mathi/Nandi wood beadings 10mm wide m 12.00
0244 mathi/Nandi wood planks for panels 25mm thick m 58000.00
0245 mathi/Nandi wood scantling cum 58000.00
0246 mathi or Nandi wood scantlings for styles and rails 30mm thick cum 58000.00
0266 Nandi wood reepers 50x25 mm m 65.00
0269 NUWUD (MDF) panel filling 19 mm thick Sqm 495.00
0286 Panel filled with NUWUD (MDF) board 12 mm thick Sqm 420.00
0294 planks for filling Sqm 12500.00
0332 Sal wood cum 46000.00
0333 Sal wood battens cum 46000.00
0389 silver oak or equivalent planks 38 mm thick cum 24000.00
0417 Teak wood cum 140000.00
0418 Teak wood beading 10mm wide m 25.00
0419 Teak wood beading 20x20 mm m 65.00
0420 Teak wood cum 140000.00
0421 Teak wood gutties Big Each 5.00
0422 Teak wood planks for panels 25 mm thick cum 160000.00
0423 Teak wood reepers 50x25 mm m 160.00
0424 Teak wood scantling for styles and rails 30mm thick cum 160000.00
0425 Teak wood scantling for styles and rails 35mm thick cum 160000.00
0426 Teak wood beads cum 160000.00
0429 TW beading for fixing glass m 20.00
0463 Wooden strips of I class teak wood (25 mm/6mm) 4mtr. Long Each 50.00
0490 Jungle wood reepers 50x25 mm m 35.00
0706 25mm thick silver oak planks Sqm 18000.00
0798 Wooden blocks Nos 172.00
0462 Wooden cleats Each 3.00
0080 Casuarina bellies 75 to 100 mm dia m 43.00
0081 Casuarina poles 100 to 150 mm m 55.00
0082 Casuarina poles 75 to 100 mm dia m 43.00
0869 Jungle wood cum 34000.00
0872 Wooden staff for fastening of flag 25mmdia, one m long Each 10.00
0961 Wooden ballies 8"dia & 9m long No. 250.00
0962 Wooden ballies 2"dia for bracing m 25.00
2002 50x35mm salwood crunnel cum 46000.00
2003 Teakwood gutties Small Nos. 2.00
2011 Teak wood beading 10mm wide m 25.00
0006 5.5mm thick plain glass Sqm 650.00
0170 Glass shelf 600x120mm with guard rail Each 920.00
0171 Glass strips Sqm 517.00
0172 Glazing clips Kgs 200.00
0467 4mm thick plain glass Sqm 500.00
0324 Reeded glass 2 mm thick Sqm 275.00
0325 Reeded glass 3 mm thick Sqm 325.00
0538 Imported glass 6 mm thick Sqm 900.00
2012 12mm thick plain tuffened glass Sqm 2300.00
2014 12mm thick frosted toughened glass Sqm 2700.00
2071 Glass etching Sqm 1350.00
0005 25 mm dia pulley (for alluminum sliding door) Each 68.00
0011 Aluminium handles - 15mm Each 58.00
0012 Aluminium hinges 75 mm length Each 38.00
0038 Bottom lock nail Each 47.00
0046 Brass screws 25 mm Each 2.10
0085 Center pulley Each 100.00
0086 Central ball bearing Each 127.00
0107 Cleat angles Each 53.00
0133 Door closure heavy duty floor mounting Each 1319.00
0134 Door lock Each 401.00
0177 Gusset plates 3.15 mm thick Kgs 61.00
0178 Handles power coated 150 mm Each 56.00
0179 Handles to full width 2m long Each 1002.00
0188 Hinges 5" heavy duty Each 37.00
0189 Hold fasts MS Each 38.00
0220 Locking arrangments Each 633.00
0222 M.S. holder bat clamp 32mm Each 44.00

0225 Each 47.00


M.S stays and clamps for 200 mm length including bolts and nuts

0226 Each 26.00


M.S stays and clamps for 50 mm length including bolts and nuts

0227 Each 33.00


M.S stays and clamps for 75 mm length including bolts and nuts
0253 MS clamps Each 38.00
0254 MS cleats with bolts and nuts to rest on pile Each 13.00
0256 MS handles oxidised 150 mm Each 63.00
0261 MS side shed clamps Each 62.00
0265 Nail and screws Kgs 54.00
0314 Pulleys 38 mm dia Each 51.00
0326 Reeper nails 50 mm long Kgs 52.00
0384 Screws 40 mm Each 3.00
0388 Side guides Each 135.00
0399 Stays (MS) Each 20.00
0427 Tower bolt 300 mm long Each 116.00
0474 Pivots Nos 550.00
0540 Screws Nos 4.00
0537 Box cleats Nos 38.00
0541 Anchor Bolts Nos 17.00
0542 Galvanized L brackets Nos 40.00
0708 Steel inserts with stainless steel bolts and nuts Kgs 74.00
0719 Bolts and nuts Kgs 84.00
0768 MS bolts, nuts and washers Tonne 89000.00
0710 Anchorages Each 120.00
0711 Anchor loops (IS 2062) Each 325.00
0712 Anchor plates (IS 2062) Each 235.00
0713 Anchorage sets Each 100.00
0094 Chrominum plated screw -25mm Each 4.00
0167 Gl 'j' or 'L' hook with nuts and bolts 8mm dia Each 17.00
0291 Pintels including welded pins Each 13.00
0492 C.P brass brackets Pair 33.00
2084 Hydraulic door clouser - aluminium body No. 897.00
0015 Aluminium paint L 198.00
0016 Aluminium paint primer (red oxide) L 99.00
0020 Anticorrosive bitumastic paint L 132.00
0033 Black Japan paint L 110.00
0131 Dark shade pigment Kgs 202.00
0132 Distemper primer L 68.00
0136 Dry Distumper Kgs 66.00
0137 Enamel metal paint L 250.00
0138 Enamel primer L 99.00
0214 Light shade pigment Kgs 180.00
0247 Medium shade pigment Kgs 215.00
0285 Paint remover L 130.00
0289 Pigment Kgs 110.00
0290 Pink primer paint L 140.00
0300 Plastic emulsion paint L 230.00
0320 Ready mix primer paint L 85.00
0321 Ready mix red lead paint L 85.00
0323 Red oxide Kgs 88.00
0430 undercoat flatting varnish L 165.00
0431 Unslaked lime qtl 450.00
0432 Varnish L 130.00
0433 Wall paint L 181.00
0435 Water proof cement paint Kgs 75.00
0438 Wax polish Kgs 250.00
0271 Oil bound distemper Kgs 66.00
0428 Turpentine Oil L 75.00
0543 Anodized M R F painting Sqm 330.00
0447 White lead paint for priming L 110.00
0461 Whitening Kgs 22.00
0528 Wax Kgs 198.00
0529 Sealer coat L 220.00
0530 Melamine Patty Kgs 210.00
0531 Melamine Polish L 220.00
0532 Thinner L 153.00
0775 Paint I quality(synthetic enamel paint) L 220.00
0776 Pigment Kgs 60.00
0784 Road marking paint L 275.00
0779 Primer L 77.00
0173 Gopi powder Kgs 60.00
0218 Linseed oil L 175.00
0219 Liquid wood filler L 220.00
0524 Sand paper Dozen 75.00
0525 50 size sand paper Dozen 75.00
0526 36 size sand paper Dozen 75.00
569 Primer Kgs. 105.00
0528 Wax Kgs 198.00
0529 Sealer Coat L 220.00
0530 Melamione Patty Kgs 210.00
0531 Melamione polish L 220.00
0532 Thinner L 153.00
0543 Anodized M R F painting Sqm 330.00
1504 Epoxy resin hardener mix for primne coat Kgs 660.00
2044 Light House Polish L 206.00
2045 Texture material Kgs 30.00
2046 Antifungal paint L 325.00
2050 Textured based white cement Kgs 40.00
2060 Soap powder Kgs 120.00
2081 Wiping cloths Each 23.00
2083 Soap oil / Phenol L 44.00
2092 Solvent cement adhesive L 194.00
0995 Water based paint for cement concrete surface L 70.00
0021 Asbestos cement pipes 75 mm dia of length 2 mtrs Each 140.00
0095 CI Bends 100 mm dia Each 338.00
0096 CI Bends 75 mm dia Each 275.00
0097 CI Bends 90 mm dia Each 143.00
0098 CI heads 100 mm dia Each 172.00
0099 CI pipes 100 mm dia of 1.8m length Each 1328.00
0100 CI pipes 75 mm dia of 1.8m length Each 1088.00
0101 CI shoes 100 mm dia Each 286.00
0102 CI shoes 110 mm dia Each 320.00
0103 CI shoes 75 mm dia Each 338.00
0146 G.I. Overflow pipe 20mm dia m 149.00
0147 G.I. Pipe 100 mm dia B class m 802.00
0148 G.I. Pipe 150 mm dia B class m 1202.00
0149 G.I. Pipe 15 mm dia B class m 109.00
0150 G.I. Pipe 20 mm dia B class m 137.00
0151 G.I. Pipe 25 mm dia B class m 197.00
0152 G.I. Pipe 32 mm dia B class m 223.00
0153 G.I. Pipe 40 mm dia B class m 279.00
0154 G.I. Pipe 50 mm dia B class m 321.00
0155 G.I. Pipe 65 mm dia B class m 480.00
0156 G.I. Pipe 80 mm dia B class m 611.00
0157 G.I. Tee 32mm Each 100.00
0158 G.I. Tee 65mm Each 350.00
0169 GI washers Each 14.00
0182 HDPE 110mm dia, 4Kg/sqcm m 183.00
0183 HDPE 110mm outer dia, 2.5Kg/sqcm m 185.00
0184 HDPE 90mm outer dia, 4Kg/sqcm m 143.00
0185 HDPE 90mm outer dia, 2.5Kg/sqcm (rain down water pipes) m 120.00
0212 P.V.C. Lead connection pipe 32 mm dia (for wash basin) Each 137.00
0303 Polythylene pipes high density 32mm external dia m 155.00
0304 Polythylene pipes high density 40mm external dia m 172.00
0305 Polythylene pipes high density 50mm external dia m 235.00
0306 Polythylene pipes high density 20mm external dia m 44.00
0307 Polythylene pipes high density 25mm external dia m 63.00
0308 Polythylene pipes high density 32mm external dia m 115.00
0309 Polythylene pipes high density 40mm external dia m 143.00
0310 Polythylene pipes high density 50mm external dia m 172.00
Sand cast iron bend 100 mm dia with access door, washers, bolts
0335 378.00
and nuts Each
Sand cast iron bend 50 mm dia with access door, washers, bolts
0336 286.00
and nuts Each
Sand cast iron bend 75 mm dia with access door, washers, bolts
0337 Each 309.00
and nuts
0338 Sand Cast iron pipe 100 mm dia 1.8m length Each 802.00
0339 Sand Cast iron pipe 50 mm dia 1.8m length Each 378.00
0340 Sand Cast iron pipe 75 mm dia 1.8m length Each 779.00
0342 Sand Cast iron plain bend 50 mm dia Each 229.00
0344 Sand Cast iron soil waste 114mm offsets 3" dia Each 326.00
0345 Sand Cast iron soil waste 152mm offsets 3" dia Each 555.00
0346 Sand Cast iron soil waste 230mm offsets 3" Each 600.00
Sand Cast iron soil waste double equal invert plain branches of
0347 Each 836.00
required degree '100x100x100x100mm
Sand Cast iron soil waste double equal invert plain branches of
0348 342.00
required degree '50x50x50x50mm Each
Sand Cast iron soil waste double equal invert plain branches of
0349 550.00
required degree '75x75x75x75mm Each
Sand Cast iron soil waste double equal junction of required degree
0350 Each 721.00
'100x100x100x100mm
Sand Cast iron soil waste double equal junction of required degree
0351 Each 342.00
'50x50x50x50mm
Sand Cast iron soil waste double equal junction of required degree
0352 with access 'door, rubber washers bolts and nuts, 916.00
100x100x100x100mm Each
Sand Cast iron soil waste double equal junction of required degree
0353 with access 'door, rubber washers bolts and nuts, 802.00
100x100x50x50mm Each
Sand Cast iron soil waste double equal junction of required degree
0354 with access 'door, rubber washers bolts and nuts, 916.00
100x100x75x75mm Each

0355 Sand Cast iron soil waste double equal junction of required degree 660.00
with access 'door, rubber washers bolts and nuts, 75x75x75x75mm Each

0356 Sand Cast iron soil waste double equal junction of required degree 492.00
with access 'door, rubber washers bolts and nuts, 75x75x50x50mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0357 607.00
required degree '100x100x75mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0359 893.00
required degree '100x100x75x75mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0360 555.00
required degree '75x75x50mm Each
Sand Cast iron soil waste double unequal invert plain branches of
0361 458.00
required degree '75x75x50x50mm Each
Sand Cast iron soil waste double unequal junction of required
0362 916.00
degree '100x100x50x50mm Each
Sand Cast iron soil waste double unequal junction of required
0363 922.00
degree '100x100x75x75mm Each
Sand Cast iron soil waste double unequal junction of required
0364 344.00
degree '75x75x50x50mm Each
Sand Cast iron soil waste single equal invert plain branches of
0365 Each 802.00
required degree '100x100x100x100mm
Sand Cast iron soil waste single equal invert plain branches of
0366 504.00
required degree '50x50x50x50mm Each
Sand Cast iron soil waste single equal invert plain branches of
0367 573.00
required degree '75x75x75x75mm Each

0368 Sand Cast iron soil waste single equal junction of required degree 573.00
with access 'door, rubber washers bolts and nuts, 75x75x75mm Each
Sand Cast iron soil waste single equal junction of required degree
0369 784.00
with access door ' 100x100x100mm Each
Sand Cast iron soil waste single equal junction of required degree
0370 441.00
with access door ' 50x50x50mm Each
Sand Cast iron soil waste single equal junction of required degree
0371 573.00
with access door ' 75x75x75mm Each
Sand Cast iron soil waste single equal junction of required degree
0372 with access 'door, rubber washers bolts and nuts, ' 802.00
100x100x100mm Each

0373 Sand Cast iron soil waste single equal junction of required degree 504.00
with access 'door, rubber washers bolts and nuts, ' 50x50x50mm Each
Sand Cast iron soil waste single unequal junction of required
0374 401.00
degree 100x100x50mm Each
Sand Cast iron soil waste single unequal junction of required
0375 Each 395.00
degree 100x100x75mm
Sand Cast iron soil waste single unequal junction of required
0376 332.00
degree 75x75x50mm Each
Sand Cast iron soil waste single unequal junction of required
0377 degree with access 'door, rubber washers bolts and nuts, 653.00
100x100x50mm Each
Sand Cast iron soil waste single unequal junction of required
0378 degree with access 'door, rubber washers bolts and nuts, 687.00
100x100x75mm Each
Sand Cast iron soil waste single unequal junction of required
0379 degree with access 'door, rubber washers bolts and nuts, 452.00
750x75x50mm Each

0380 Sand Cast iron soil waste double equal junction of required degree 573.00
with access 'door, rubber washers bolts and nuts, 50x50x50x50mm Each
0381 Sand cast iron trap 100mm dia Each 567.00
0382 Sand cast iron trap 50mm dia Each 447.00
0383 Sand cast iron trap 75mm dia Each 498.00
0393 Special for overflow pipe Each 40.00
0402 Stoneware pipes 100mm dia 60 cms long Each 60.00
0403 Stoneware pipes 150mm dia 60 cms long Each 100.00
0404 Stoneware pipes 200mm dia 60 cms long Each 140.00
0405 Stoneware pipes 230mm dia 60 cms long Each 150.00
0406 Stoneware pipes 250mm dia 60 cms long Each 160.00
0407 Stoneware pipes 300mm dia 60 cms long Each 175.00
0408 Stoneware pipes 350mm dia 60 cms long Each 180.00
0409 Stoneware pipes 400mm dia 60 cms long Each 190.00
0410 Stoneware pipes 450mm dia 60 cms long Each 225.00
0476 100 mm dia asbestos dia cement pipe of length 2 mtrs Each 120.00
110 mm outer dia 2 kg/sqcm pressure pipe of approved make
0477 172.00
(PVC) m
110 mm outer dia 2.5 kg/sqcm pressure pipe of approved make
0478 177.00
(PVC) m
90 mm outer dia 2kg/sqcm pressure pipe of approved make (PVC)
0479 132.00
m
Sand cast iron soil waste double equal junction of required degree,
0493 527.00
75x75x75x75 mm m
0534 M S Square pippe 16 G Black pipe Kg 57.00
0702 100 mm asbestos cement pipes m 50.00
0703 100 mm dia 1 m long GI pipe m 824.00
0755 HDPE pipes-90 mm dia m 120.00
0782 RCC pipes NP3 1200 mm dia including collars m 7250.00
0783 RCC pipes NP3 900 mm dia including collars m 4650.00
0821 RCC pipes NP3 300 mm dia including collars m 1100.00
0822 RCC pipes NP3 450 mm dia including collars m 2050.00
0823 RCC pipes NP3 600 mm dia including collars m 2600.00
0824 RCC pipes NP3 750 mm dia including collars m 2850.00
0825 RCC pipes NP2 300 mm dia including collars m 800.00
0826 RCC pipes NP2 450 mm dia including collars m 1100.00
0827 RCC pipes NP2 600 mm dia including collars m 1700.00
0828 RCC pipes NP2 750 mm dia including collars m 2100.00
0829 RCC pipes NP2 900 mm dia including collars m 2750.00
0830 RCC pipes NP2 1200 mm dia including collars m 4750.00
0831 RCC pipes NP4 900 mm dia including collars m 5650.00
0832 RCC pipes NP4 1200 mm dia including collars m 9100.00
565 RCC pipes NP2 150 mm dia including collars m 300.00
566 RCC pipes NP2 250 mm dia including collars m 400.00
0911 RCC pipes 200mm dia, 2.5m long for drainage m 250.00
0929 Plastic tubes 50cm dia, 1.2m high Nos. 36.00
565 RCC pipes NP 2, 150 mm dia including collar m 300.00
566 RCC pipes NP 2, 250 mm dia including collar m 400.00
568 RCC NP 4 100 mm dia including collars m 8350.00
0001 100mm 'S' or 'P' trap Each 60.00
0023 Bevel lead mirror of superior glass of size 600x450mm Each 850.00
0024 Bib cock 15mm nominal bore-NP Each 170.00
0025 Bib cock 20mm nominal bore-NP Each 189.00
0026 Bib cock 25mm nominal bore-NP Each 212.00
0027 Bib cock 32mm nominal bore-NP Each 287.00
0028 Bib cock 40mm nominal bore-NP Each 287.00
0029 Bib cock 50mm nominal bore-NP Each 343.00
0034 black plastic seat and lid as specified Each 286.00
0040 Brass ball vlave with plastic float 15mm nominal bore Each 280.00
0041 Brass ball vlave with plastic float 20mm nominal bore Each 300.00
0042 Brass ball vlave with plastic float 25mm nominal bore Each 450.00
0043 Brass ferrule and C.1 Mouth cover 15mm nominal bore Each 100.00
0044 Brass ferrule and C.1 Mouth cover 20mm nominal bore Each 150.00
0045 Brass ferrule and C.1 Mouth cover 25mm nominal bore Each 180.00
0047 Brass shower rose C.P 100mm dia Each 555.00
0048 Brass shower rose C.P 150mm dia Each 600.00
0049 Brass stop cock-15mm Each 200.00
Brass union 15mm nominal bore with PVC connection pipe 300mm
0050 Each 150.00
length Each
Brass union 15mm nominal bore with PVC connection pipe 450mm
0051 Each 175.00
length
Brass union 20mm nominal bore with PVC connection pipe 300mm
0052 175.00
length Each
Brass union 20mm nominal bore with PVC connection pipe 450mm
0053 200.00
length Each
0067 C.I manhole cover with frame 610x455mm size (38 Kgs) Each 2200.00
0068 C.I/M.S. brackets for flushing cistern Pair 100.00
0069 C.I Cover 500mm dia -50mmthick(16Kgs) Each 1030.00
0070 C.P brass chain plug Each 125.00
0071 C.P brass chain with stainless steel plug Each 215.00
0072 C.P.brass pillar tap elbow operated Each 460.00
0073 C.P. brass screws 25mm with washers Each 5.00
0074 C.P.brass towel rail 600mm length 20mm dia Each 450.00
0075 C.P.brass towel rail 740mm length 20mm dia Each 500.00
0076 C.P.brass waste union 32mm of standard pattern Each 120.00
0077 C.P.brass waste union 40mm with fittings Each 183.00
0079 Cast iron foot rest Each 131.00
Circular shape mirror of size 450mm dia with plastic moulded
0105 515.00
frame Each
0114 Copper plated brass piller tap Each 230.00
Gun metal non-return valve 100mm nominal bore horizontal type
0117 2290.00
Each
0118 Gun metal non-return valve 100mm nominal bore verticall type Each 2347.00
0119 Gun metal non-return valve 25mm nominal bore horizontal type Each 515.00
0120 Gun metal non-return valve 25mm nominal bore vertical type Each 415.00
0121 Gun metal non-return valve 32mm nominal bore horizontal type Each 665.00
0122 Gun metal non-return valve 32mm nominal bore vertical type Each 665.00
0123 Gun metal non-return valve 40mm nominal bore horizontal type Each 859.00
0124 Gun metal non-return valve 40mm nominal bore vertical type Each 802.00
0125 Gun metal non-return valve 50mm nominal bore horizontal type Each 1202.00
0126 Gun metal non-return valve 50mm nominal bore vertical type Each 1145.00
0127 Gun metal non-return valve 65mm nominal bore horizontal type Each 1660.00
0128 Gun metal non-return valve 65mm nominal bore vertical type Each 1431.00
0129 Gun metal non-return valve 80mm nominal bore horizontal type Each 1947.00
0130 Gun metal non-return valve 80mm nominal bore vertical type Each 1740.00
0139 Europian type water closet of specified make Each 1050.00
0143 G.I 32mm dia telescopic flush pipes with fittings/specials Set 350.00
G.I.Flush pipe of standard size and C.P brass spreaders,brass
0144 Set 500.00
unions and clamps 'including fittings
0145 G.I jam nut Each 23.00
0159 Gate valve 15mm nominal bore-gun metal Each 250.00
0160 Gate value 20mm nominal bore-gun metal Each 316.00
0161 Gate value 25mm nominal bore-gun metal Each 460.00
0162 Gate value 32mm nominal bore-gun metal Each 750.00
0163 Gate value 40mm nominal bore-gun metal Each 1000.00
0164 Gate value 50mm nominal bore-gun metal Each 1600.00
0165 Gate value 65mm nominal bore-gun metal Each 2050.00
0166 Gate value 80mm nominal bore-gun metal Each 2462.00
indian type water closet of size 580 mm of specified make with
0204 687.00
footrests Each
0273 Orissa pattern of size 575x425 mm with integal type foot rests Each 1400.00
0274 580.00
Oval shape mirror of size 450x350 mm with plastic moulded frame Each
0275 P.V.C automatic flushing cistern 7.5 litres with fittings Each 687.00
0276 P.V.C automatic flushing cistern with fittings 10 litres Each 744.00
0277 P.V.C automatic flushing cistern with fittings 15 litres Each 801.00
P.V.C flushing cistern 10 litres low level with accessories 40mm
0278 650.00
flush pipe Each
0279 P.V.C pipes unplasticised 16mm m 44.00
0280 P.V.C pipes unplasticised 20mm m 46.00
0281 P.V.C pipes unplasticised 25mm m 56.00
0282 P.V.C pipes unplasticised 32mm m 65.00
0283 P.V.C automatic flushing cistern 5 litres with fittings Each 500.00
0284 P.V.C flushing cistern 10 litres low level with fittings Each 600.00
0411 stop cock Each 125.00
0434 water meter Each 744.00

0302
Polyethylene water storage tank of specified capacity and make L 6.20
Rectangulur shape mirror of size 1500x450mm with drain board of
0322
specific make Each 1144.00
Stainless steel kitchen sink of size 400x470mm with drain board of
0396 Each 4500.00
specific make
Stainless steel kitchen sink of size 500x1000mm with drain board
0397
of specific make Each 6900.00
Stainless steel kitchen sink of size 510x1575mm with drain board
0398
of specific make Each 13600.00
0440 White glazed fire clay kitchen sink of size 600x450x250mm Each 1400.00
0441 White glazed fire clay kitchen sink of size 750x450x250mm Each 1660.00
0442 White glazed fire clay laboratory sink of size 450x300x150mm Each 900.00
0443 White glazed fire clay laboratory sink of size 600x450x200mm Each 1145.00

0446 White glazed/vitreous china clay 10 lts low level flushing cistern,
with fittings and \brakets and 40mm white C.P flush pipe Set 1832.00

0449 Each 773.00


White vitreous china clay angle back wash basin size 500x400mm
0450
White vitreous china clay angle back wash basin size 600x480mm Each 1000.00
White vitreous china clay flat back lipped front urinal basin of
0451
430x260x350mm size Each 700.00
White vitreous china clay flat back large urinal basin size
0453
580x380x350mm Each 2060.00

0454
White vitreous china clay flat back wash basin size 450x330mm Each 600.00

0455 Each 780.00


White vitreous china clay flat back wash basin size 550x400mm

0456
White vitreous china clay flat back wash basin size 630x450mm Each 900.00
0457 White vitreous china clay squatting plate Each 1000.00
White vitreous china clay surgeon type wash basin size
0458 Each 1000.00
600x450x250mm
White vitreous china clay wall corner type, lipped front urinal basin
0460 Each 630.00
of size '340x410x265mm
0487 C.P. brass tap with union Each 285.00
Rectangulur shape mirror of size 453x357mm with plastic moulded
0491 802.00
frame Each
0546 ceeramic tiles of size 30x30cms Sqm 435.00
2035 Colour Glazed tiles 30x60cms 6mm thick Each 85.00
2096 L. Bracket Nos. 29.00
0542 Galvanized L brackets Nos 40.00
2079 Granite sink 23cm thick Each 10305.00
2098 Rubber Gaskete m 17.00
0083 Caustic soda Kgs 46.00
0092 Chiken mesh Sqm 19.00
0168 GI plaster mesh 0.35 mm thick 10 cms wide m 35.00
0251 Mosquito proof coupling 25 mm Each 29.00
0295 Plaster mesh 100mm wide m 23.00
0296 Plaster mesh 150mm wide m 29.00
0297 plaster mesh 200mm wide m 35.00
0318 Rabbit wire mesh Sqm 63.00
0548 Weld Mesh 75mmx25mm of 6G to 10G Sqm 280.00
0549 Weld Mesh 75x50mm of 6G to 10G Sqm 213.00
0729 Copper plate 12 m long x 250 mm wide Kgs 460.00
Wire create size(1.8x1.8mx0.9m)=2.916(4mm dia 2GI wire in 15
0796 172.00
cms x 15 cms mesh) Kgs
0797 Wire mesh 50 mm x 50 mm Sqm 322.00
0816 Form work for kerb stone/KM stone Sqm 20.00
0104 Cinder ballast cum 287.00
0093 Chlorophriphos emulstiable concentrate L 200.00
0065 Burnt lime/shell lime q 450.00
0141 Fly ash cum 20.00
0142 Fuel (firewood) q 550.00
0210 Kerosene oil L 45.00
0215 Lime cum 4000.00
0216 Lime surkhi mortar 1:2 cum 550.00
0263 Mud mortar cum 230.00
0267 Nitric Acid L 80.00
0299 Plaster of Paris Kgs 21.00
0394 Spirit L 46.00
0412 Surkhi cum 345.00
0436 Water proofing compound Kgs 46.00
0483 Diesel L 62.00
0709 Admixture/Super Plasticizer L 207.00
0715 Bentonite Tonne 4800.00
0741 Epoxy for mortar Kgs 172.00
0742 Epoxy for tack coat Kgs 345.00
0743 Epoxy material for fixing Kgs 207.00
0760 Joint filler (0.01 cm wide and 0.12mm wide) Sqm 230.00
0761 Joint sealing com 25 mm deep Kgs 168.00
0811 Chloroperene C.C. 1.00
0812 Natural Rubber C.C. 1.00
0813 Neoprene Kgs 230.00
0818 Water KL 40.00
0268 Nortlight adjustable ridges of 1.22m Pair 160.00
0270 Nylon rollers Each 6.00
0315 Putty for filling holes Kgs 80.00
0319 Rawl Plug 40 to 50mm Each 2.50
0317 PVC Beading m 12.00
Roofing felt type-2 grade-1 fibre based self finish and bitumen
0328 110.00
based Sqm
0329 Rubber heading for shutturs beading m 35.00
0392 Spun yarn Kgs 40.00
0413 Suspension shaft m 950.00
0516 Plastic sheet Sqm 6.00
0527 Steel wool Pack 25.00
0535 Glazing seal m 350.00
0536 Weather Seal Nos 200.00
0539 Specer tape Sqm 40.00
0704 20mm thick compressible fiber band 12 m long x 25 cm deep Sqm 410.00
0705 20 mm thick filler 12m long x 25 cm deep Sqm 430.00
0737 Deviator Plates Tonne 46000.00
Elastomeric slab with MS plates inserted inside polysulphine
0740 0.50
compound filling Space around Bolts and nuts C.C.
0774 Nipples Each 10.00
0788 Sheething duct ID m 15.00
0809 PTFE Nodules Sq.cm 8.00
0810 PTFE Nodules cm 0.10
0331 S.F.R.C. Cover and frame 560 mm (ID) heavy duty Each 900.00
0850 Fine Grass Kgs. 7.00
0851 Hedge plant Each 3.00
0852 Flowring plants Each 2.50
0853 Shrubs Each 2.00
0854 Sapiling 2m high 25mm dia Each 10.00
0855 Neem cake q 900.00
0856 Empty bitumen drum Each 100.00
0857 Rivets Each 3.00
0858 Steel wire 3mm dia Kgs 45.00
0859 Sapling 1 to 1.5m high 2cm dia stem Nos. 8.00
0861 Traffic cones with 150mm reflective sleeve Nos. 400.00
0871 Flag of red color cloth 600x600mm Each 20.00
0900 Supply of quarried stone 150-200 size cum 420.00
0901 Stone boulder of size 150mm and below cum 402.00
Precast cement concrete tiles Tiles size 300x300mm and 25mm
0910 26.00
thick Nos.
1104 Jute Rope m 5.50
0925 cold miling machine at 20cum per hour cum 20.00
0927 Scrap types of size 900x20 Nos. 218.00
0928 20mm steel wire rope Kgs. 40.00
0933 Geotextile filter frabic Sqm. 76.00
0934 perforated geosynthetic pipe 150mm dia m 250.00
0935 Paving fabric Sqm. 20.00
0936 Geogrids Sqm. 310.00
0937 Connectors/staples Each 6.00
0938 Polymer braids m 32.00
0945 Hot applied thermoplatic compound L 110.00
0946 Reflectorising glass beads Kgs. 55.00
Cost of approved type of delineators from ISI certified firm as per
0947 260.00
the standard drawing given in IRC:79 Each
0948 Barbed wire 335 metre length at 9.38 kg per 100 metre Kgs. 35.00
0960 Sand bags(cost of sand in empty cement bag) No. 50.00
0964 Admixture Kgs. 65.00
0966 M 35 grade RCC corbel provided for supporting of euipment cum 4200.00
0971 NUTS AND Bolts Kgs. 52.00
Elastomeric slab seal expansion joint assembly manufactured by
0980 using chloroprene, elastomer for elastomeric slab unit conforming 12660.00
to clause 9150.1 of IRC:83 (part II) conforming to clause 2600.6 of
Morth specifications. m
Preformed continuous chloroprene elastoemer or closed cell foam
0982 sealing sealing element with high mtear strength vulcanised in a 13715.00
single operation for the full length of a joint ot ensure water
tightness. m

0983 Supply of complete assembly of strip seal expansion joint 12325.00


comprising of edge beams, anchorage, strip seal element and
complete accessories as per approved specifications and drawings m
Supply of a modular strip/box seal joint assembly comprising of
edge beams, central beam, 2 modules chloroprene seal,
0984 anchorage elements, support and control system, all steel sections 5697.00
protected against corrision and installed by the manufacturer or his
authorised representative. m

Supply of a modular/box/box seal joint assembly containing 3


0985 modules/cells and comprising of edge beams, two central beams, 6857.00
chloroprene seal, anchorage elements, support and control
system, all steel sections protected against corrosion and installed
by the manufacturer or his authorised representative. m
0986 LDO L 42.00
0987 Trailor 30 Tonne capacity hr 1000.00
0990 Farmyard manure cum 110.00
0991 Seeds Kgs. 120.00
0992 Jute netting Sqm 14.00
0994 Doob grass Kgs. 34.00
0997 Accelerator compound for guniting Kgs. 21.00
0998 Wire mess 50mm x 50mm size of 3mm wire Kgs. 42.00
1101 Sodium vapour lamp - 250 watt Each 1319.00
Pre - packed ploymer concrete based on epoxy system complete
1502 10.00
with curing compound, intiator and promoter Kgs.
1505 Quick setting compound Kgs. 158.00
1507 Acrylic polymer bonding coat L 400.00
Pre-packed cement based ploymer mortar of strength 45 Mpa at
1508 200.00
28 days Kgs.
Epoxy resin with pot life not less than 60-90 minutes and satisfying
1509 575.00
testing as per clause 2800.3.9 Kgs.
1514 bearing Neoprene No. 2089.00
Separation membrane of impermeable plastic sheeting 125 micron
1521 4.00
thick Sq.cm
1522 Pre-moulded joint filler, 25mm thick for expansion joint Sq.cm 7.00
1523 Joint sealant Kgs. 180.00
1524 Sealant Primar Kgs. 150.00
1525 Curing compound L 220.00
Super plasticizer admixture IS marked as per 9-103-1999 at 0.5%
1526 70.00
by wt. of cement Kgs.
1552 Collar for AC pipe (average) Nos, 69.00
Elastomeric bearing assembly consting of 7 layers of elastomer
1555 bonded to 6 nos. reinforcing steel laminates by the process of 10076.00
vulcanisation, complete with all components as per drawings and
technical specifications. Nos.

Pot type bearing consisting of a metal piston supported by a


1556 disc,PTFE pads providing sliding surfaces against stainless steel 80500.00
mating together with cast steel assemblies/ fabricated structural
steel assemblies duly painted with all components as per clause
2006 and complete as per drawing and technical specifications. Nos.
547 Expanded metal 12.5 mm to 25 mm -14 G Sqm 280.00
548 Weld Mesh 75mmx25mm of 6G to 10G Sqm 230.00
549 Weldmesh 75 x 50mm of 6g x 10g Sqm 213.00
552 Pesticide L 280.00
553 Granite slabs 7.5 cm to 8 cm thick sqm. 100.00
557 Guard stones 700 mm X 200 mm X 200 mm Nos. 87.00
559 15 mm bolt Nos. 9.00
560 60 x 60 x10 Guage sq.plate washer Kgs. 39.00
570 Sealant Kgs. 115.00
563 PVC Storage Tank L 5.00
564 12x12 guage GI wire 100 mtr at Ts. 8.00/m m 12.00
574 Steel Helmet and Cushion block Kgs. 60.00
Vibrating pile driving hammer complete with hour unit and
575 150.00
accessaries hr
0930 Geonets Sqm 65.00
0931 Geomembrane Sqm 65.00
0932 Geotextile Sqm 65.00
2001 Carbon electrodes cm 0.50
2004 Screws 3.5" Nos. 4.00
2005 Screws 1.75" Nos. 2.00
Latch, Pivot, Locking arrangements, SS door rails etc for glass
8000.00
2013 doors Set
2023 Cast iron ornamental design Nos 80.00
2024 Cast iron arrows No 85.00
2025 Expansion bolt No 29.00
2052 Coconut Broom stick No. 40.00
2053 Bombay broom stick No. 55.00
2054 Squeezer / wiper / rubber brushes No. 90.00
2055 Coir brushes No. 35.00
2056 Bamboo baskets No. 105.00
2057 Plastic buckets 20 L capacity No. 120.00
2058 Trollies No. 1600.00
2064 Cobble stone 65mm thick Sqm 340.00
2065 Cobble stone 80mm thick Sqm 470.00
2072 Welding rods Nos 5.00
2037 Ball beaing hinges heavy duty Nos. 287.00
2041 G.I. Coated expansion bolts Nos. 35.00
2048 Ball Joints Kgs 180.00
2049 Design-Trowel Nos. 57.00
2059 Hose pipe 30m length No. 830.00
2061 Plastic Mug Each 30.00
2063 Bleaching Powder Kgs 80.00
2066 Bronze multiwall polycorbonate G.E. make Kgs 1200.00
2070 Sealent taps Joint 6.00
2080 Mop stick - alluminium No. 120.00
2082 Disposable garbage bags size 0.9m x 1.5m Each 11.50
2087 RBI Grade 81 Tonne 32840.00
2088 Safe N Easy/Equivalent Bio-degradable L 499.00
2093 Polymeric expansion joints filler - 12mm thick Sqm 540.00
2094 Polymeric expansion joints filler - 18mm thick Sqm 781.00
2095 Polymeric expansion joints filler - 22mm thick Sqm 1081.00
2102 Crystallisation liquid Kgs 150.00
2103 Isoproof Kgs 300.00
2104 Acrylic Kgs 200.00
2105 FCM Kgs 70.00
2106 Non woven geo textile Kgs 85.00
2107 Polysulphide /acrylic sealant Kgs 310.00
2112 No. 3.00
9001 Gulty Trap No. 30.00
2097 5mm Semi finished PVC Sheet Sqm 510.00
3001 PVC Pipes 10KG/Sqm 90mm outerdia M 350.00
3002 PVC Pipes 10KG/Sqcm 110mm outerdia M 510.00
3003 PVC Pipes 10KG/Sqcm 140mm outerdia M 840.00
3004 PVC Pipes 10KG/Sqcm 160mm outerdia M 1080.00
3005 PVC Pipes 10KG/Sqcm 180mm outerdia M 1400.00
3006 PVC Pipes 10KG/Sqcm 200mm outerdia M 1700.00
3007 PVC Pipes 10KG/Sqcm 225mm outerdia M 2100.00
3008 PVC Pipes 10KG/Sqcm 250mm outerdia M 2600.00
3009 PVC Pipes 10KG/Sqcm 280mm outerdia M 3300.00
3010 PVC Pipes 10KG/Sqcm 315mm outerdia M 4200.00
3022 Water less urinal of size 328x319x598mm Each 24500.00
2203 Galvanised Steel 105 x 50 mm M 210.00
2204 Galvanised Steel 20 x 47 mm M 105.00
2205 Galvanised Steel 58 x 36 mm M 160.00
2206 Galvanised Steel 22 x 20 (FW 66 mm) M 45.00
2207 Galvanised "C" Section 12 x 3 M 20.00
2208 Float Glass 5 mm Thick Sqm 470.00
2212 M.S. Grill Powder Coated 100 mm Pitch Sqm 700.00
221 Galvanised "C" Section 18 x 7 (FW 33 mm) M 22.00
2209 Galvanised Steel20 x 24 (FW 33 mm) M 47.00
2213 Galvanised Steel 90 x 50 mm M 200.00
2214 TMT Bars Fe 500 M 44500.00
2215 TMT Bars Fe 550 M 45000.00
2216 Maranthi Wood cum 36200.00
2217 Galvanised Steel 70 x 55 mm M 193.00
2218 Galvanised Flymesh Section 20 x 40 mm M 130.00
2219 Galvanised Steel Section 48 x 25 mm M 175.00
2220 Galvanised Steel (Glass Beading ) 12 x 12 mm M 1.00
2221 Mesh (SS 304 Grade) Sqm 350.00
2222 Galvanised Steel 72 x 55 mm M 195.00
2223 Galvanised Steel Section 48 x 50 mm M 180.00
2224 Galvanised Steel Section 46 x 52 mm M 175.00
2225 Galvanised Steel Section 46 x 46 mm M 165.00
2226 Galvanised Beading Section 18 x 25 mm M 62.00
2227 Fly ash bricks of size 60 x 20 x 15 cm 100 No. 600.00
2228 White cement based putty Kgs 26.00
Vitrifed tiles - 10 mm thick double charged, nano technology size
Sqm
800mmx800mm 1000.00
Vitrifed tiles - 10 mm thick double charged, nano technology size
Sqm
1200mmx600mm 2000.00
Light weight Concrete (Autoclaved aereated cellular)Blocks of size
Each
3023 60 x 20 x 15 cm 100.00
Solid blocks concrete 40 x 15 x 20 cms 100 No. 3500.00
Light weight Concrete (Autoclaved aereated cellular)Blocks of size
Each
3024 60 x 20 x 10 cm 60.00
Light weight Concrete (Autoclaved aereated cellular)Blocks of size
Each
3025 60 x 20 x 20 cm 120.00
3027 Polymer modified stucco mortar Kg 23.00
Sal wood (Red) cum 42000.00
2229 Precast Hallow blocks (40x20x20 cm) grade 50 100 No. 4300.00
2280 Solid blocks concrete (40 x 15 x 20 cms) grade 35 100 No. 4100.00
580 Raw-silk granite 20mm thick Sqm 1300.00
Table top 25mm thick PLPB with edge banding Sqm 1900.00
75mm thick MS CRCA partition with PLPB tiles Sqm 3000.00
25 mm thick PLPB separator with edge handing Sqm 1900.00
L clamps No. 5.00
Nut and bolt No. 4.00
Separator and D-Brackets No. 30.00
Cantilever Brackets No. 95.00
End table hode on Bracket No. 35.00
Corner Hook on Bracket No. 35.00
25mm thich front modesty Sqm 1800.00
25mm thich legs sqm 2150.00
Minifix housing No. 4.00
Wooden dowels M8x40 No. 1.50
M6 screw leg No. 6.00
M6 Insert No. 5.00
64 mm dia grommet cap No. 10.00
50mm thick glass wool Sqm 165.00
Wood screws No. 4.00
Ahro tape/press putty Bundle 298.00
Lipping 1”x ¼ “ Rmt 24.30
Etching of glass Sqm 1350.00
Patch fittings No. 1400.00
Pivot No. 350.00
Floor machine No. 6500.00
Locking system No. 1000.00
SS Door rails Set 700.00
25mm treated commercial black board Sqm 1900.00
Teak wood balls No. 200.00
19mm block board vinyl bonded w/p 7’x3’ Sqm 1150.00
Notes Provided in SR 2014 - 15

Note - 1

Note - 2

Note - 3

Note 1

Note 2

Note 1

Note 1

Note 2

Note 1

Note 1

Note 1

Note 1
Note 1

Note 2

Note3

Note4

Note

Note 1.

Note 2.

Note 3.

Note 4.

Note 5.

Note

Note.1

Note.2
Note.3
Note.4
Note 1

Note 2

Note 3

Note 4

Note 5

Note 1

Note 2

Note 3

Note 4

Note 5
Note

Class of
Occupancy

Group A

Group B

Group C
Group D

Group E

Group F

Group G
Group H

Group J

NOTES : 1 LH - Low Hazard, 2 MH - Medium Hazard, 3 HH - High Hazard, 4 SH: Special Hazard.

B-2 RECOMMENDED SCALE OF EQUIPMENT TO BE INSTALLED


B-2.1 Class A
LH

MH
HH

Special
Hazard
LH

MH
HH

LH
MH
HH

HH
Notes Provided in SR 2014 - 15
1.0 - MORTAR
…………………………………………………………..
2.0 - EARTH FOR BUILDINGS
Adopt item 2.24 for excavation in all types of soils for lowering & levelling the ground for building works
by mechanical means

KSRB 2.2 Excavation for foundation of buildings, water supply sanitary lines, electrical conduits either in
pits or in trenches where excavation width is above 600 mm below 1.5 mtrs. depth add 25% extra and for
width upto 600 mm add 50% extra for respective rates due to restricted conditions.
KSRB 2.2 Extra for excavation under water conditions and/or foul conditions including bailing/pumping
out, removing slush add 20% of the rate of the respective rate on account of slow progress of work under
these conditions.
3.0 - ANTI TERMITE TREATMENT
…………………………………………………………..
4.0 - CEMENT CONCRETE
Lift charges: An additional rate of Rs.50.00/cum per floor may be added for every additional floor for
items under Sl.No. 4.1 to 4.13 and Rs.5.00/sqm per floor may be added for every additional floor for
items under Sl.No. 4.19, 4.20, 4.27, 4.55, 4.56, 4.57, 4.58.1, 4.58.2, 4.28 to 4.42. For 4.43.1 to 4.44.4
an additional rate of Rs. 5.0/floor may be added.
Centering height of 3.5 meters is considered for item No. 4.28, 4.30 to 4.44.4. An additional rate Rs. 20
shall be added for every additional meter or part thereof for the above limits.
5.0 - STONE WORK
Additional rate of Rs. 30.00/Sqm. for item no. 5.24, 5.25, 5.26, 5.27, 5.28, 5.34 for every additional floor.
6.0 - BRICK WORK

Lift charges: The above rates are applicable for Ground floor only. An additional rate of Rs. 50.00/cum
and Rs. 5/sqm per floor may be added for every additional floor above or below the ground floor.
Add 10% extra for gable portion.
7.0 -STEEL AND ALUMINIUM WORK
Lift charges: The above rates are applicable for Ground and basement floors only. Add an additional rate of Rs.
5.00/sqm per floor above or below.
8.0 - ROOFING
…………………………………………………………..
9.0 - WOOD WORK
Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.3.00/sqm per floor may be added for every additional floor for items vide Sl.No.9.6 to 9.9, 9.14 to
9.99, 9.101, 9.102 and 9.106
10.0 WATER PROOFING
…………………………………………………………..
11.0 DRAINAGE WORK
…………………………………………………………..
12.0 SANITARY WORK
…………………………………………………………..
13.0 WATER SUPPLY WORK
Add 15% extra for internal water supply items.
14.0 FLOORING
Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.1.50/sqm per floor may be added for every additional floor for items vide Sl.No.14.1 to 14.72.
15.0 FINISHING WORK
Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.5.00/sqm per floor for plastering works only may be added for every additional floor.

Lift charges: The above rates are applicable for Ground and basement floors only. An additional rate of
Rs.3.00/sqm per floor for painting works of exterior walls only may be added for every additional floor.

Scaffolding charges : An additional rate of Rs. 10.00/sqm per floor for external plastering works only may
be added for every additional floor.
Scaffolding charges : An additional rate of Rs. 3.00/sqm for painting works of exterior walls only maybe
added for every additional floor.
16.0 REPAIRS TO BUILDINGS
…………………………………………………………..
17.0 ROADS and BRIDGES Carriage of Materials
…………………………………………………………..
18.0 SITE CLEARANCE and DISMANTLING
…………………………………………………………..
19.0 EARTH WORK, EROSION CONTROL and DRAINAGE
…………………………………………………………..
20. 0 SUB BASES, BASES (Non Bituminous) and SHOULDERS
KSRRB-400-2,4
This analysis provides for median and island with earthen top. In
case the surface is required to be turfed or planted with shrubs,
the same is required to be provided separately.
KSRRB M400-20. Construction of Shoulders
A. Earthen Shoulders. The rate as applicable for sub-grade
construction may be adopted.
B. Hard Shoulders. Rate as applicable for sub-base and or base
may be adopted as per approved design.
C. Paved Shoulders. The rate may be adopted as applicable
for different layers of pavement depending upon approved
design of paved shoulders.
Cost of flyash has not been considered as same will be availablefree of cost. Only
carriage of flyash has been provided.
Lime + Flyash has been taken as 20% of total mass and ratio of
lime and flyash as 1:4 for estimating purposes. Total quantities
will be as per approved design.
Ground granulated blast furnace slog/slag sand may be used for
item No. 20.1, 20.2, 20.3, 20.4, 20.5, 20.6, instead of river sand, grit
and 6mm below aggregate or in combinations.
21.0 BASE and SURFACE COURSES (Bituminous)
NOTE : KSRRB 500-11, 13, 16, 17, 18, 19,
Labour for traffic control, watch and ward and other miscellaneous
duties at site including sundries have been included in administrative
overheads of the contactor.
Where tack coat is required to be provided before laying mastic
asphalt, the same is required to be measured and paid separately.
affinity for bitumen as a condition for the approval of that source the
bitumen
test andshall be treated with
determination approved binder
of bituminous anti stripping
contentagent as per the
and gradation
of aggregates in the mix and (c) determination of density and
22.0 CONCRETE PAVEMENT
…………………………………………………………..
23.0 GEOSYTHETIC and REINFORCED EARTH
…………………………………………………………..
24.0 TRAFFIC SIGNS, MARKINGS
…………………………………………………………..
25.0 BRIDGES - PILE FOUNDATION
…………………………………………………………..
26.0 BRIDGES - WELL FOUNDATIONS
KSRRB M 1200-13.3,14.3, 15.3, 16.3, 17.3, 18.3, 19.3, 20.3, 21.3,22.3, 23.3, 24.3, 25.3, 26.3, 27.3 and
28.3 beyond 10m upto 20m - Add 5% for every additional meter depth of sinking over the rate for
sinking of previous meter (for - 10m to 11m/ 11m to 12m/ 12m to 13m/ 13m to 14m/ 14m to 15m/ 15m to
16m/ 16m to 17m/ 17m to 18m/ 18m to 19m/ 19m to 20m)
KSRRB M 1200-13.4,14.4, 15.4, 16.4, 17.4, 18.4, 19.4, 20.3, 21.4,22.4, 23.4, 24.4, 25.4, 26.4, 27.4 and
28.4 beyond 20m upto 30m - Add 7.5% for every additional meters of depth of sinking over the rate of
sinking for the pervious meter (for - 20m to 21m/ 21m to 22m/ 22m to 23m/ 23m to 24m/ 24m to 25m/
25m to 26m/ 26m to 27m/ 27m to 28m/ 28m to 29m/ 29m to 30m)

KSRRB M 1200-13.4,14.4, 15.4, 16.4, 17.4, 18.4, 19.4, 20.3, 21.4,22.4, 23.4, 24.4, 25.4, 26.4, 27.4 and
28.4 beyond 20m upto 30m - Add 20%of cost for Kentledge including supports, loading arrangement and
labour where cost is 80% of finished rate of previous meter (for - 20m to 21m/ 21m to 22m/ 22m to 23m/
23m to 24m/ 24m to 25m/ 25m to 26m/ 26m to 27m/ 27m to 28m/ 28m to 29m/ 29m to 30m)

KSRRB M 1200-13.5,14.5, 15.5, 16.5, 17.5, 18.5, 19.5, 20.5, 21.5, 22.5, 23.5, 24.5, 25.5, 26.5, 27.5 and
28.5 beyond 30m upto 40m. - Add 10% for every additional meters of depth of sinking over the rate of
sinking for the pervious meter (for - 30m to 31m/ 31m to 32m/ 32m to 33m/ 33m to 34m/ 34m to 35m/
35m to 36m/ 36m to 37m/ 37m to 38m/ 38m to 39m/ 39m to 40m)

KSRRB M 1200-13.5,14.5, 15.5, 16.5, 17.5, 18.5, 19.5, 20.5, 21.5, 22.5, 23.5, 24.5, 25.5, 26.5, 27.5 and
28.5 beyond 30m upto 40m. - Add 20% of cost for Kentledge including supports, loading ar- rangements
and labour where cost is 80% of finished rate of previous meter.(for - 30m to 31m/ 31m to 32m/ 32m to
33m/ 33m to 34m/ 34m to 35m/ 35m to 36m/ 36m to 37m/ 37m to 38m/ 38m to 39m/ 39m to 40m)

27.0 BRIDGES - OPEN FOUNDATIONS


KSRRB M2100-1.1, KSRRB M2100-1.2, KSRRB M2100-1.3, KSRRB M2100-2.1, KSRRB M2100-2.2,
KSRRB M2100-2.3, KSRRB M2100-3.1, 3.2, 4.1, 4.2 Add 10% extra for dewatering charges and
specification is to be modified accordingly.
KSRRB M2100-5.1 : Add 30% extra for dewatering charges and specification is to be modified
accordingly.
KSRRB M2100-5.2: Add 20% extra for dewatering charges and specification is to be modified
accordingly.
Add 15% extra for shoring and shuttering for items KSRRB M2100-5.1 specification is to be modified
accordingly
Add 10% extra for shoring and shuttering for items KSRRB M2100-5.2 specification is to be modified
accordingly.
28.0 BRIDGES - SUB STRUCTURE
…………………………………………………………..
29.0 BRIDGES - CONCRETE SUPER STRUCTURE
…………………………………………………………..
30.0 BRIDGES -RIVER TRAINING and PROTECTION WORKS
…………………………………………………………..
31.0 BRIDGES - EXPANSION JOINTS
…………………………………………………………..
32.0 BRIDGES -WEARING COAT and APPURTENANCES
…………………………………………………………..
33.0 BRIDGES - REPAIRS and REHABILITATION
…………………………………………………………..
34.0 PIPE CULVERTS
…………………………………………………………..
35.0 MAINTENANCE OF ROADS
…………………………………………………………..
36.0 REINFORCED EARTH STRUCTURE
…………………………………………………………..
37.0 OTHER ITEMS
…………………………………………………………..
38.0 INNOVATIVE ITEMS
…………………………………………………………..
39.0 FURNISHING WORKS
The rate for the items 39.14.1, 39.14.2, 39.15.1, 39.15.2, 39.16.1,
39.16.2, 39.16.3, 39.16.4, 39.16.5 & 39.16.6 are for the complete unit
as per the drawing appended.
40.0 FIRE FIGHTING WORKS
…………………………………………………………..

ANNEX B
(Clause 5.3, IS2190:2010)
RECOMMENDATIONS FOR INSTALLATION OF FIRE EXTINGUISHERS
B-1 occupancies classified according to IS 1641 are given together with nature of fire hazard and type of
fire risk along with typical
examples. The classifications, groupings etc., given in this Annex are only for general guidance for
installation of fire extinguishers and not
for other purposes.

Type of
Occupancy

Residential
buildings

Educational
buildings

Institutional
buildings
Assembly
buildings D-1

D-2

D-3

D-3

D-4 & D-5


Business
buildings E-1
E-2
E-3

Mercantile
buildings
Industrial
buildings
Storage
buildings

hazardous

NOTES : 1 LH - Low Hazard, 2 MH - Medium Hazard, 3 HH - High Hazard, 4 SH: Special Hazard.

B-2 RECOMMENDED SCALE OF EQUIPMENT TO BE INSTALLED


Occupancy

Occupancy
Occupancy

B-2.2 Class B
Occupancy

Occupancy
Occupancy

B-2.3 Class C

Occupancy
Occupancy
Occupancy
B-2.4 Class D

Occupancy
NOTES -
1. The recommendations are minimum for a specific area.Incase, the area is more than specified, high
capacity extinguishers may be
used based on these minimum requirements,that is proportionately higher capacity can be used.
2. In case of dry powder /Co2/clean agent types, equivalent lower capacities may also be used.
3. The halons shall be restricted for essential use only.
4. On implementation of IS 15683, 6 kg and 9 kg dry powder extinguishers shall be replaced by 5 kg or
10 kg dry powder extinguishers.
Nature of Class of
Occupancy Fire Typical Examples
Lodging or rooming, one or two family houses, Private
dwellings dormitories,
LH Class A apartment houses, flats, upto 4 star hotels, etc
Small Kitchens having LPG connection, electrical heaters,
LH Class C etc.
Multi-storeyed buildings, multi-risk buildings, five star hotels,
MH Class A etc.
Tutorials, vocational training institutes, evening colleges,
LH Class A commercial institutes
MH Class A Schools, Colleges, etc

MH Class A Hospitals, sanatoria, homes for aged, orphanage jails, etc.


Theatres, Assembly halls, Exhibition halls, Museums,
Restaurants, Places of
Worship, Club rooms, Dance halls, etc., Having seating
capacity of over
HH Class A 100 persons
Theatres, Assembly halls, Exhibition halls, Museums,
Restaurants,
Places of Worship, Club rooms, Dance halls etc. Having
seating capacity less
MH Class A than 1000 persons

Theatres, Assembly halls, Exhibition halls, Museums,


Restaurants, Places of
Worship, Club rooms, Dance halls etc. but having
accommodation for more than
300 persons, but less than 1000 persons, with no permanent
seating
MH Class A arrangement

Theatres, Assembly halls, Exhibition halls, Museums,


Restaurants, Places of
Worship, Club rooms, Dance halls etc. but having
accommodation for more than
300 persons, but less than 1000 persons, with no permanent
seating
MH Class A arrangement
Theatres, Assembly halls, Exhibition halls, Museums,
Restaurants,
Places of Worship, Club rooms, Dance halls etc. Having
accommodation less
MH Class A than 300 and those not covered under D-1 to D-3
Offices, Banks, Record Rooms, Archives, Libraries, data
SH Class A processing centres, etc.
MH Class B Laboratories, research establishment, test houses etc.
SH Class A Computer installations
Shops, Stores, Markets, Departmental stores, Underground
shopping centres,
MH Class A etc.

LH Class A Small industrial units


Corrugated carton manufacturing units, Paper cane units,
Packing case
MH Class A manufacturing units, cotton waste manufacturing units.
Large number yards, saw mills godowns and warehouses
storing combustible
HH Class A materials, cold Storages, freight depots, etc.
Demonstration chemical plants, small chemical, processing
LH Class B plants, pilot plants, etc.
Workshops, painting shops, large kitchens, industrial
canteens, generator rooms,
heat treatment shops, tread rubber manufacturing units,
petrol bunks, tubes &
MH Class B flaps units, etc.,
Petroleum processing units, chemical plants, industrial
alcohol plants, effluent
HH Class B treatment plants etc.
LH Class C
MH Class C
HH Class C
HH Class D
Flammable liquid stores, storage in drums and cans in open,
paints and
MH Class B varnishes godown.
Tank farmes chemical and petroleum bulk storage depots,
large service stations,
truck and marine terminals, underground LDO/furnace oil
HH Class B storage yards, etc.
LPG distribution godown/office, distribution storage
godowns/offices of
MH Class C D, N, H, Argon and other industrial gases
Storage and handling of gas cylinders in bulk, gas plant, gas
holders (Horton),
HH Class C spheres, etc.

Buildings used for storage, handling, manufacture and


processing of highly
combustible explosive materials. (Risks involved in terms of
class of fire
and intensity of fire has to be assessed on case to case basis
and statutory
authorities to be consulted, environmental factors and mutual
aid facilities to be
taken into account before deciding on the fire extinguisher
requirements.)

ard.
One 9 litre
water
expelling
extinguisher or
ABC 5kg/6 kg
fire
extinguisher,
for every 200
m2 of floor
area or part
there of with
minimum of
two
extinguishers
per
compartment
or floor of the
building. The
extinguishers
should be
so located as
to be available
within 15 m
radious.

Two 9 litre
water
expelling
extinguisher or
ABC 5kg/6 kg
fire
extinguisher,
for every 200
m2 with
minimum of
4
extinguishers
per
compartment
or floor .The
extinguishers
should be so
located as to
be available
within 15 m
radious.
Provision as
per MH
occupancy, in
addition to one
50 litre water
CO2/ 25 kg
ABC fire
extinguisher
for every
100 m2 of
floor area or
part thereof.

One 4.5 kg
capacity
carbon dioxide
or one 2/3 kg
capacity clean
agent
extinguisher
for every 100
m2 of floor
area or part
there of with
minimum of
two
extinguishers
so located as
to be available
within 10 m
radious.
One 9 litre
foam
extinguisher,
mechanical or
BC or ABC, 5
kg / 6 kg fire
extinguisher,
for every 200
m2 of floor
area or part
there of with
minimum of
two
extinguishers
per
compartment
or floor. The
extinguishers
located as
to be available
within 15m
radious.

Two 9 litre
foam
extinguisher,
mechanical
type, or 5/6 kg
dry powder
extinguisher
(or one of
each type) for
every
200 m2 area
with minimum
of four
extinguisher
per
compertment.
Extinguisher
should be
available
within 15 m
radious.
Provision as
per MH, and in
addition to one
50 litre
mechanical
foam type
extinguisher or
25 kg BC fire
extinguisher
for every 100
m2 or part
thereof one
135 litre foam
mechanical
extinguisher
for every 300
m2 of
floor area or
part thereof.

One 2/3kg dry


powder of
clean agent
extinguisher
for every 20
m2 of floor
area or part
thereof;
extinguisher
available
within 15 m
radious.
One 10kg dry
powder
extinguisher(st
ored pressure)
or 6.5kg
carbon dioxide
extinguisher or
5kg clean
agent for
100 m2 of
floor area or
part thereof,
with minimum
of one
extinguisher of
the same type
for every
compartment;
extinguisher
should be
available
within a
radious of
15m, the same
type for every
compartment;
extinguisher.
Dry powder
extinguisher
(stored
pressure) of
10 kg or 6.5
Kg CO2
extinguisher,
or 5 kg clean
agent
extinguisher
for every 100
m2 of floor
area or part
thereof,
subject to a
minimum of
two
extinguishers
of same type
per room
or
compartment.
Extinguishers
should be
available
within a radius
of 10 m.

One 10 kg dry
powder
extinguisher
with special
dry powder for
metal fires for
every 100 m2
of floor area or
part
thereof with
minimum of
two
extinguisher
per
compartment/
room.
Extinguishers
should be
available
within a
radius of 10m.
Circle Year
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15

PWD Bangalore Circle 2014-15


PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
PWD Bangalore Circle 2014-15
Weighta
Description ge
Bruhat Bangalore Mahanagara Palike Limits (BBMP limits) a) For Buildings 6
Bruhat Bangalore Mahanagara Palike Limits (BBMP limits)b) For Roads and Bridges 8
BMRDA Limits- All taluks under Bangalore (Urban) and Bangalore (Rural) district and Ramanagara
District 3
Work carried out at bangalore Central Prison, Parappana Agrahara 10
Level-wise Percentage for hill stations MOTARABLE AREA 0-25 mtr. Nil
Level-wise Percentage for hill stations MOTARABLE AREA More than 25mtrs.- upto 150mtr. 5
Level-wise Percentage for hill stations MOTARABLE AREA More than 150mtrs. - upto 300 mtr. 10
Level-wise Percentage for hill stations MOTARABLE AREA More than 300mtrs. - upto 450 mtr. 15
Level-wise Percentage for hill stations MOTARABLE AREA More than 450mtrs. - upto 600 mtr. 20
Level-wise Percentage for hill stations MOTARABLE AREA Above 600mtr. 25
Other State Works a)Tirumala Hills (Andhra Pradesh) 25
Other State Works b)Ooty (Tamil Nadu) 25
Other State Works c)For other state works taken up by PW, P and IWTD 25
MINING Upto 5 Kms radius of mining area 4
Sugar Factory Area / Cement Factory Area (Upto 5 kms radius) 4
Forest Area 5
Chikkanayakanahally in Tumkur Dt. 3
Gubbi in Tumkur Dt. 2
Pavagada in Tumkur Dt. 2
Name Quantity uom
Filling Foundation with granite metal 1.00 Cum
Rubble stone masonry in foundation with mud 1.10 Cum
Mortar
Rubble stone masonry in foundation with 1.10 Cum
cement Mortar
Rubble stone in 1:8 in foundation with
masonry 1.10 Cum
cement
Size stone Mortar
masonryin 1:6
in basement with
mudMortar 1.05 Cum
Size stone masonry in foundation with
cement Mortar 1:8 1.05 Cum
Size stone masonry in foundation with 1.05 Cum
cement Mortar 1:6
Size stone masonry in basement with 1.440 Cum
cementMortar
Size stone masonry 1:6 in super structure with
1.449 Cum
cement
Size stone mortar
masonry1:6 in super structure with
1.449 Cum
cement mortar
Hallow block masonry 1:4 in cement mortar 1:4
40x20x20 cms 50kg/sqcm 12.11 Nos.
Hallow block masonry in cement mortar 1:4 12.11 Nos.
40x20x20 cms 35kg/sqcm
Hallow block masonry in cement mortar 1:4 12.11 Nos.
40x10x20 cms 35kg/sqcm
Solid block masonry in cement mortar 1:4 12.11 Nos.
40x20x20
Solid blockcms 35kg/sqcm
masonry in cement mortar 1:4
12.11 Nos.
40x10x20 cms 35kg/sqm
Non modular CL35 brick masonry in mud mortar
for basement
Non modular CL35and super
brick structure
masonry in 485 sqm
cementmortar 1:8 for basement and super 485 cum
Non modular CL35 brick masonry in cementmortar 1:6 for basement and super
structure 485 cum
Non modular CL50 table moulded brick masonry
structure
in cement mortar 1:8 for basement and super 485 cum
Non modular CL50 table moulded brick masonry
structure
in
Noncement
modular mortar
CL501:6 for moulded
table basementbrick
and masonry
super 485 cum
structure
in
Noncement
modular mortar
CL751:4 for basement
machine moulded and super
brick 485 cum
structure
masonry in cement mortar 1:8 for basement
Non modular CL75 machine moulded brick and 456 cum
super
masonry structure
in cement mortar 1:8 for basement
Non modular CL75 machine moulded brick and 456 cum
super
masonry structure
in cement mortar 1:4 for basement and 456 cum
Non
super modular
structure CL75 machine moulded brick
masonry in cement mortar 1:3 for basement and 456 cum
super structure
modular CL35 brick msonry in cement
mortar 520 cum
modular1:8 CL35for brick
basement
masonryandin
super structure
cement
mortar 1:6
modular CL50for table
basement
mouldedand brick
supermasonry
structurein 520 cum
cement mortar 1:6 for basement
modular CL50 table moulded brick masonry and super in 520 cum
structure
cement
modularmortar
CL50 table1:6 for basement
moulded brickand super in
masonry 520 cum
structure
cement mortar 1:4 for basement and super 520 cum
modular
structure CL75 machine moulded brick masonry
in cement
modular CL75 mortar 1:8 formoulded
machine basement andmasonry
brick super 520 cum
structure
in cement mortar 1:6 for basement
modular CL75 machine moulded brick masonry and super 520 cum
structure
in cementCL75
modular mortar 1:4 formoulded
machine basement andmasonry
brick super 520 cum
structure
in cement mortar 1:3 for basement and super 520 cum
Nonmodular CL35 brick partition wall 11.2cms
structure 66.80 sqm
Nonmodular
thick in cm 1:4 CL50
withtable moulded brick partition
G I plastermesh
wall 11.2 cms thick in cm 1:4 with G I 66.80 sqm
Nonmodular CL35 brick partition wall 11.2 cms
plastermesh 66.80 sqm
thick in cm 1:4
Nonmodular CL50 table moulded brick partition 66.80 sqm
wall 11.2 cms thick in cm 1:4
modular CL35 brick partition wall 10 cms thick in 56.70 sqm
cm 1:4 G CL50
modular I plastermesh
table moulded brick partition wall 56.70 Sqm
10 cms thick in
modular CL35 brick cm 1:4 with Gwall
partition I plastermesh
10 cms thick in
cm 1:4 56.70 Sqm
modular CL50 table moulded brick partition wall
10 cms thick in cm 1:4 58.70 Sqm
Providing and laying flooring with B.S. slab 10 cm 0.11 sqm
thick on sand
Providing and bed
laying
7.5flooring
cm to 8with
cm thick
B.S. slab
and 10
pointed
cm writer cm 1:3
thick on C.M. bed 1:6, 25mm thick and pointed 0.11 sqm
with C.M. 1:3
Providing and laying flooring and steps machine
cut granite slabs 40mm thick on C.M. bed 1:6, -
25mm thick, and pointed with C.M. 1:3 over 0.11 sqm
Providing
existing ccand
bedlaying flooring and steps 0.11 sqm
fine dressed granite
Providing and laying flooring and steps 0.105 sqm
fine dressed granite
Providing & Laying heavy duty cobble stones (60mm) 0.105 sqm
Providing & Laying heavy duty cobble stones (75mm) 0.105 sqm
Flooring with 1:2:4cc 0.035 sqm
Flooring with 1:2:4cc with red oxide 0.026 sqm
Flooring 40mm thick with an underlay of 30mm thick cc1:2:4 0.026 sqm
Metallic floor hardner 2.6 kg 0.1 sqm
Metallic floor hardner 2.6 kg 0.043 sqm
marble chips 17.3 kgs, marble powder 0.0017 0.025 sqm
marble chips -0.56
cum pigment 17.3kgs
kgs, marble powder - 0.0017cum,
white cement - 0.16 kgs, pigment Sqm 0.025 0.0125 0.18 0.025 sqm
Marble chips - 17.3 kgs, white cement 0.08 bags,
334 0.025 sqm
marble powder - 0.0017 cum, pigment
marble chips - 17.3 kgs, white cement 0.16 kgs 0.025 sqm
marble powder - 0.0017 cum
Limesurkhi Mortar of mix 1:1 0.7125 Cum
Limesurkhi Mortar of mix 1:2 0.95 Cum
Limesurkhi Mortar of mix 1:3 1.07 Cum
Limesurkhi Sand Mortar of mix 1:1:1 0.475 Cum
Limesurkhi Sand Mortar of mix 1:1:2 0.357 Cum
Cement Mortar with Stone dust of mix 1:2 6.95 Cum
White cement Mortar with Marble 1:2 dust of mix 0.95 Cum
White cement Mortar with Marble dust of mix 1:3 1.07 Cum
White cement Mortar with Marble dust of mix1:4 1.07 Cum
White cement Mortar with Marble dust of mix 1:5 1.07 Cum
Fly ash sand Mortar of mix 1:1.5:3 0.357 Cum
Fly ash sand Mortar of mix 1:2:4 0.356 Cum
Fly ash sand Mortar of mix 1:2.5:5 0.356 Cum
Fly ash sand Mortar of mix 1:3.6:5 0.366 Cum
Cement mortar of mix 1:1 0.7125 Cum
Cement mortar of mix 1:2 0.95 Cum
Cement mortar of mix 1:3 1.07 Cum
Cement mortar of mix 1:4 1.07 Cum
Cement mortar of mix 1:5 1.07 Cum
Cement mortar of mix 1:6 1.07 Cum
Cement mortar of mix 1:8 1.07 Cum
Cement mortar of mix 1:10 1.07 Cum
Lime Mortar of mix 1:1 0.7125 Cum
Lime Mortar of mix 1:2 0.95 Cum
Lime Mortar of mix 1:3 1.07 Cum
Limesurkhi Sand Mortar of mix 1:1:1 0.475 Cum
Limesurkhi Sand Mortar of mix 1:1:2 0.357 Cum
Cement Lime Mortar of mix 1:1:3 0.86 Cum
Cement Lime Mortar of mix 1:1:4 1.07 Cum
Cement Lime Mortar of mix 1:1:5 1.07 Cum
Cement Lime Mortar of mix 1:1:6 1.07 Cum
Cement Lime Mortar of mix 1:1:7 1.07 Cum
Cement Lime Mortar of mix 1:1:8 1.07 Cum
Cement Lime Mortar of mix 1:2:9 1.07 Cum
Cement Lime Mortar of mix 1:3:2 1.07 Cum
Fly ash sand Mortar of mix 1:1.5:3 0.7150 Cum
Fly ash sand Mortar of mix 1:2:4 0.7150 Cum
Fly ash sand Mortar of mix 1:2.5:5 0.7150 Cum
Fly ash sand Mortar of mix 1:3.6:5 0.7150 Cum
Sand filling 1.0000 Cum
Filling Foundation with granite metal 0.50000 Cum
Sand cement bed with 5% cement 1.0000 Cum
Sand cement bed with 10% cement 1.0000 Cum
Sand Piles 0.0140 Cum
Sand cement Piles 0.014 Cum
Rubble stone masonry in foundation with mud 0.33 Cum
Mortar
Rubble stone masonry in foundation with
0.35 Cum
cement Mortar
Rubble stone in 1:8 in foundation with
masonry
cement Mortar in 1:6 0.35 Cum
Size stone masonry in foundation with mud 0.28 Cum
Mortar
Size stone masonry in foundation with 0.30 Cum
cement Mortar
Size stone masonry1:8 in foundation with
0.30 Cum
cement Mortar
Size stone masonry1:6 in basement with
cementMortar 1:6 in super structure with 0.30 Cum
Size stone masonry
cement mortar 1:6 0.30 Cum
Size stone masonry in super structure with 0.30 cum
cement mortar 1:4
Hallow block masonry in cement mortar 1:4 0.02 sqm
40x20x20 cms 50kg/sqcm
Hallow block masonry in cement mortar 1:4 0.02 sqm
40x20x20 cmsmasonry
Hallow block 35kg/sqcm in cement mortar 1:4 0.012 sqm
40x10x20 cms 35kg/sqcm
Solid block masonry in cement mortar 1:4
40x20x20 0.02 sqm
Solid blockcms 35kg/sqcm
masonry in cement mortar 1:4
40x10x20 cms 35kg/sqm 0.012 sqm
Non modular CL35 brick masonry in mud mortar 2.40 sqm
for basement
Non modular CL35
and super
brick structure
masonry in
cementmortar
Non modular CL35 1:8 for basement
brick masonryandin super 0.26 cum
structure
cementmortar 1:6 for basement and super 0.26 cum
Non modular CL50 table moulded brick masonry
structure
in cement
Non modular mortar
CL501:8 for moulded
table basementbrick
and masonry
super 0.26 cum
structure
in cement mortar 1:6 for basement and
Non modular CL50 table moulded brick masonry super 0.26 cum
structure
in
Noncement
modularmortar
CL751:4 for basement
machine moulded and super
brick 0.26 cum
structure
masonry in cement mortar 1:8 for basement and 0.26 cum
Non modular CL75 machine moulded brick
super
masonrystructure
in cement mortar 1:8 for basement
Non modular
super structure CL75 machine moulded brick and 0.26 cum
masonry
Non modular CL75 machine moulded brick and
in cement mortar 1:4 for basement 0.26 cum
super
masonrystructure
in cement mortar 1:3 for basement and 0.26 cum
super structure
modular CL35 brick msonry in cement 0.225 cum
mortar 1:8 for basement and super structure
modular CL35 brick masonry in cement 0.225 cum
mortar 1:6
modular CL50
for table
basement
moulded
and brick
supermasonry
structurein
cement mortar 1:6 for basement and super 0.225 cum
modular
structureCL50 table moulded brick masonry in
cement
modular mortar 1:6 for basement and super 0.225 cum
structureCL50 table moulded brick masonry in
cement
modularmortar 1:4 for basement
CL75 machine and super
moulded brick masonry 0.225 cum
structure
in cement mortar 1:8 for basement and super 0.225 cum
modular CL75 machine moulded brick masonry
structure
in cement mortar 1:6 for basement and super 0.225 cum
structure
modular CL75 machine moulded brick masonry
in cementCL75
modular mortar 1:4 formoulded
machine basement andmasonry
brick super 0.225 cum
structure
in cement mortar 1:3 for basement and super 0.225 cum
Nonmodular CL35 brick partition wall 11.2cms
structure 0.026 sqm
thick in cm 1:4
Nonmodular CL50
withtable
G I plastermesh
moulded brick partition
wall 11.2 cms thick in cm 1:4 with G I 0.026 sqm
Nonmodular CL35 brick partition wall 11.2 cms
plastermesh 0.026 sqm
thick in cm 1:4
Nonmodular CL50 table moulded brick partition
wall 0.026 sqm
modular CL35 thick
11.2 cms brick in cm 1:4 wall 10 cms thick in
partition
cm 1:4 G I plastermesh 0.022 sqm
modular CL50 table moulded brick partition wall 0.022 sqm
10 cms thick in cm 1:4 with G I plastermesh
modular CL35 brick partition wall 10 cms thick in 0.022 sqm
cm 1:4 CL50 table moulded brick partition wall
modular 0.022 sqm
10 cms thick inlaying
Providing cm 1:4
Providing and
and laying flooring
flooring with
with B.S.
B.S. slab
slab 10
10 cm
cm 0.0088 sqm
thick on sand bed 7.5 cm
thick on C.M. bed 1:6, to 8thick
25mm cm thick
and and pointed writer cm 1:3
pointed
Providing
with C.M. and
1:3 laying flooring and steps machine 0.0043 sqm
cut granite slabs 40mm thick on C.M. bed 1:6, - 0.0033 sqm
25mm thick, and pointed with C.M. 1:3 over
Providing
existing ccand
bedlaying flooring and steps 0.0031 sqm
fine dressed granite
Providing and laying flooring and steps 0.0028 sqm
fine dressed granite
Providing & Laying heavy duty cobble stones (60mm) 0.005 sqm
Providing & Laying heavy duty cobble stones (75mm) 0.005 sqm
Flooring with 1:2:4cc 0.018 sqm
Flooring with 1:2:4cc with red oxide 0.025 sqm
Flooring 40mm thick with an underlay of 30mm thick cc1:2:4 0.025 sqm
Metallic floor hardner 2.6 kg 0.016 sqm
Metallic floor hardner 2.6 kg 0.02 sqm
Tandoor blue slab 1.15 sqm, pigment 0.45 kg 0.028 sqm
Shahabad slab 1.15 sqm, pigment 0.45 kg 0.028 sqm
cudapa slab 1.15 sqm, pigment 0.45 kg 0.028 sqm
marble chips 17.3 kgs, marble powder 0.0017 0.012 sqm
cum pigment
marble chips -0.56
17.3kgs
kgs, marble powder - 0.0017cum,
white 0.0125 sqm
Marblecement
chips - -17.3
0.16kgs,
kgs,white
pigment
cement 0.08 bags,
marble powder - 0.0017 cum, pigment 0.0125 sqm
marble chips - 17.3 kgs, white cement 0.16 kgs 0.012 sqm
marble powder - 0.0017 cum
mosaic tiles - 1.1 sqm, pigment - 0.30 kgs 0.028 sqm
white cement - 0.08 bags, pigment - 0.30 kgs 0.028 sqm
mosaic tiles - 1.1 sqm, white cement - 0.04 bags, 0.028 sqm
pigment - 0.30tiles
white mosaic kgs - 1.10 sqm,
white cement - 0.17 bags 0.028 sqm
checkered mosaic tiles - 1.10 sqm, pigment - 0.3 kgs 0.013 sqm
checkered mosaic tiles - 1.10 sqm, 0.013 sqm
white cement - 0.088 bags, pigment - 0.3 kgs
mosaic tiles - 1.10 sqm, white cement - 0.04 bags, 0.013 sqm
pigment - 0.30 kgs
mosaic tiles - 1.10 sqm, white cement - 0.17 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 0.013 sqm
marble slabs - 1.15 sqm, white cement - 0.01 bags 0.028 sqm
. 0.02 sqm
red oxide - 0.28 kg 0.02 sqm
glazed tiles - 46 nos. 0.01 sqm
glazed tiles - 46 nos. 0.01 sqm
glazed tiles - 46 nos. 0.01 sqm
glazed tiles - 46 nos. 0.01 sqm
marble slab - 1.15 sqm 0.012 sqm
Finishing Work 0.002 sqm
Finishing Work 0.002 sqm
Finishing Work 0.002 sqm
Finishing Work 0.002 sqm
Finishing Work 0.004 sqm
Finishing Work 0.004 sqm
Finishing Work 0.001 sqm
Finishing Work 0.001 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.01 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.02 sqm
Finishing Work 0.013 sqm
Finishing Work 0.013 sqm
Providing tough cement plastering cm 1:4 0.017 sqm
Providing tough cement plastering cm 1:6 0.017 sqm
Marble chips - 0.87 kgs, 0.031 sqm
marble powder - 0.0007 cum, pigment - 0.285 kgs
White cement - 0.41 kg, Marble chips - 0.87 kgs, 0.03 sqm
Marble powder - 0.0007 cum, pigment - 0.285 kgs
White cement - 0.04 bags, Marble chips - 8.7 kgs, 0.03 sqm
Marble powder- -0.08
White cement 0.0007 cum,
bags, pigment
Marble chips- -0.28 kgs
8.7 kgs, 0.03 sqm
Marble powder - 0.0007 cum
Mosaic tiles - 1.10 sqm 0.012 sqm
Mosaic tiles - 1.10 sqm, pigment 0.462 kgs 0.012 sqm
Mosaic tiles - 1.10 sqm, white cement - 0.066 bags, pigment 0.55 kgs 0.01 sqm
Mosaic tiles - 1.10 sqm, white cement - 0.13 bags 0.01 sqm
Repairs to Building 0.0010 Sqm
Repairs to Building 0.0010 Sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.020 sqm
Repairs to Building 0.0050 sqm
Repairs to Building 0.0200 sqm
Repairs to Building 0.0020 sqm
Repairs to Building 0.0020 sqm
Cement Mortar of mix 1:1 1020.00 Kgs
Cement Mortar of mix 1:2 680.00 Kgs
Cement Mortar of mix 1:3 510.00 Kgs
Cement Mortar of mix 1:4 380.00 Kgs
Cement Mortar of mix 1:5 310.00 Kgs
Cement Mortar of mix 1:6 250.00 Kgs
Cement Mortar of mix 1:8 190.00 Kgs
Cement Mortar of mix 1:10 150.00 Kgs
Lime Mortar of mix 1:1 451.00 Kgs
Lime Mortar of mix 1:2 301.00 Kgs
Lime Mortar of mix 1:3 226.00 Kgs
Limesurkhi Mortar of mix 1:1 451.00 Kgs
Limesurkhi Mortar of mix 1:2 301.00 Kgs
Limesurkhi Mortar of mix 1:3 226.00 Kgs
Limesurkhi Sand Mortar of mix 1:1:1 301.00 Kgs
Limesurkhi Sand Mortar of mix 1:1:2 226.00 Kgs
Cement Mortar with Stone dust of mix 1:2 680.00 Kgs
Cement Lime Mortar of mix 1:1:3 410.00 Kgs
Cement Lime Mortar of mix 1:1:3 181.00 Kgs
Cement Lime Mortar of mix 1:1:4 380.00 Kgs
Cement Lime Mortar of mix 1:1:4 170.00 Kgs
Cement Lime Mortar of mix 1:1:5 310.00 Kgs
Cement Lime Mortar of mix 1:1:5 135.00 Kgs
Cement Lime Mortar of mix 1:1:5 250.00 Kgs
Cement Lime Mortar of mix 1:1:6 113.00 Kgs
Cement Lime Mortar of mix 1:1:6 220.00 Kgs
Cement Lime Mortar of mix 1:1:7 97.00 Kgs
Cement Lime Mortar of mix 1:1:7 190.00 Kgs
Cement Lime Mortar of mix 1:1:8 84.00 Kgs
Cement Lime Mortar of mix 1:1:8 170.00 Kgs
Cement Lime Mortar of mix 1:2:9 151.00 Kgs
Cement Lime Mortar of mix 1:2:9 130.00 Kgs
Cement Lime Mortar of mix 1:3:2 170.00 Kgs
White cement Mortar with Marble 1:2 dust of mix 680.00 Kgs
White cement Mortar with Marble dust of mix 1:3 510.00 Kgs
White cement Mortar with Marble dust of mix 1:4 380.00 Kgs
White cement Mortar with Marble dust of mix 1:5 310.00 Kgs
Fly ash sand Mortar of mix 1:1.5:3 340.00 Kgs
Fly ash sand Mortar ofmix 1:2:4 250.00 Kgs
Fly ash sand Mortar of mix 1:2.5:5 200.00 Kgs
Fly ash sand and Mortar of mix 1:3:6:5 160.00 Kgs
Sand cement bed with 5% cement 71.40 Kgs
Sand cement bed with 10% cement 142.80 Kgs
Sand cement Piles 2.00 Kgs
KSRB 4.1.1: Providing and laying ...... cement concrete of mix M15 240.00 Kgs
KSRB 4.1.2 : Providing and laying ...... cement concrete of mix M10 220.00 Kgs
KSRB 4.1.3 : Providing and laying ...... cement concrete of mix M 7.5 180.00 Kgs
KSRB 4.1.4 : Providing and laying ...... cement concrete of mix M 5 160.00 Kgs
KSRB 4.1.5 : Providing and laying ...... cement concrete of mix M 20 300.00 Kgs
KSRB 4.1.6 : Providing and laying ...... cement concrete of mix M 15 240.00 Kgs
KSRB 4.1.7 : Providing and laying ...... cement concrete of mix M 10 220.00 Kgs
KSRB 4.2.1 : Providing and laying ...... cement concrete of mix M 25 340.00 Kgs
KSRB 4.2.2 : Providing and laying ...... cement concrete of mix M 20 320.00 Kgs
KSRB 4.2.3 : Providing and laying ...... cement concrete of mix M 15 240.00 Kgs
KSRB 4.2.4 : Providing and laying ...... cement concrete of mix M 10 220.00 Kgs
KSRB 4.2.9 : Providing and laying ...... cement concrete of mix M 15 240.00 Kgs
KSRB 4.2.10 : Providing and laying ...... cement concrete of mix M 20 24.00 Kgs
KSRB 4.2.11 : Providing and laying ...... cement concrete of mix M 20 27.20 Kgs
Providing and laying readymix concrete ...... M20 320.00 Kgs
Providing and laying readymix concrete ...... M25 340.00 Kgs
Providing and laying readymix concrete ...... M30 360.00 Kgs
Providing and laying readymix concrete ...... M35 390.00 Kgs
Providing and laying readymix concrete ...... M40 420.00 Kgs
Providing and casting reinforced CC racks ...... M20 16.00 Kgs
Providing RCC loft (atta) 30.00 Kgs
Providing RCC loft (atta) 30.00 Kgs
Rubble stone masonry in foundation with 62.70 Kgs
cement Mortar in 1:8
Rubble stone masonry in foundation with 82.50 Kgs
cement Mortar
Size stone in 1:6
masonry in foundation with 53.20 Kgs
cement Mortar 1:8
Size stone masonry in foundation with
cement Mortar 1:6 in basement with 70.00 Kgs
Size stone masonry
cementMortar 1:6 70.00 Kgs
Size stone masonry in super structure with 70.00 Kgs
cement mortar 1:6
Size stone masonry in super structure with 106.40 Kgs
cement mortar 1:4
Hallow block masonry in cement mortar 1:4 7.36 Kgs
40x20x20 cmsmasonry
Hallow block 50kg/sqcm in cement mortar 1:4 7.38 Kgs
40x20x20 cms 35kg/sqcm
Hallow block masonry in cement mortar 1:4
40x10x20 4.09 Kgs
Solid blockcms 35kg/sqcm
masonry in cement mortar 1:4
40x20x20 cms 35kg/sqcm 7.38 Kgs
Solid block masonry in cement mortar 1:4 4.09 Kgs
40x10x20 cms 35kg/sqm
Providing and fixing pre cast solid concrete kerb size 450x200x400x500mm 11.72 Kgs
Providing and fixing pre cast solid concrete kerb size 450x150x500mm 11.00 Kgs
Providing
Non modularandCL35
fixingbrick
pre cast solid in
masonry c.c kerb stones 8.235 Kgs
cementmortar
Non modular CL351:8 for
brickbasement
masonryandin super 45.60 Kgs
structure
cementmortar 1:6 for basement and super 60.00 Kgs
Non modular CL50 table moulded brick masonry
structure
in cement mortar 1:8 for basement and super 45.60 Kgs
Non modular CL50 table moulded brick masonry
structure
in
Noncement
modularmortar
CL501:6 for moulded
table basementbrick
and masonry
super 60.00 Kgs
structure
in
Noncement
modularmortar
CL751:4 for basement
machine moulded and super
brick 91.20 Kgs
structure
masonry in cement mortar 1:8 for basement
Non modular CL75 machine moulded brick and 45.60 Kgs
super
masonrystructure
in cement mortar 1:8 for basement and 80.00 Kgs
super structure
Non modular CL75 machine moulded brick
masonry in cement
Non modular mortar 1:4
CL75 machine for basement
moulded brick and 91.20 Kgs
super structure
masonry in cement mortar 1:3 for basement and 122.40 Kgs
super structure
modular CL35 brick msonry in cement 39.90 Kgs
mortar 1:8
modular CL35for brick
basement andin
masonry super structure
cement 52.50 Kgs
mortar 1:6
modular CL50
for table
basement
moulded
and brick
supermasonry
structurein
cement mortar 1:6 for basement and super 39.90 Kgs
modular
structureCL50 table moulded brick masonry in
cement
modular mortar 1:6 for basement and super 52.50 Kgs
structureCL50 table moulded brick masonry in
cement
modularmortar 1:4 for basement
CL75 machine and super
moulded brick masonry 79.80 Kgs
structure
in cement mortar 1:8 for basement and super 39.90 Kgs
modular CL75 machine moulded brick masonry
structure
in cement mortar 1:6 for basement and super 52.50 Kgs
modular
structureCL75 machine moulded brick masonry
in cement mortar 1:4 for basement and super 79.80 Kgs
modular
structureCL75 machine moulded brick masonry
in cement mortar 1:3 for basement and super 107.10 Kgs
structure
Nonmodular 9.12 Kgs
Nonmodular CL35
CL50 brick
table partition
moulded wall
brick11.2cms
partitionthick
wallin11.2
cm cms
1:4 with
thickGinI plastermesh
cm 1:4 with 9.12 Kgs
GI Plasermesh
Nonmodular CL35 brick partition wall 11.2 cms thick in cm 1:4 9.12 Kgs
Nonmodular CL 50 table moulded brick partion wall 11:2 cms thick in cm 1:4 9.12 Kgs
modular CL35 brick partition wall 10 cms thick in
7.98 Kgs
cm 1:4 G CL50
modular I plastermesh
table moulded brick partition wall
10 cms thick in cm 1:4 with G I plastermesh 7.98 Kgs
modular CL35 brick partition wall 10 cms thick in 7.98 Kgs
cm 1:4
modular CL50 table moulded brick partition wall 7.98 Kgs
10 cms thick in cm 1:4
KSRB 12-5.1: Construction brick masonry circular type manhole 0.91 m internal dia 300.00 Kgs
KSRB 12.5.2 - -do- 1.67m 362.00 Kgs
KSRB 12-5.3 : -do- 1.22m internal dia 553.00 Kgs
KSRB 12-5.4: -do- 2.29m deep 633.00 Kgs
KSRB 12-5.5 : Construction brick masonry circular type manhole 1.52 m internal dia 1000.00 Kgs
KSRB 12-5.6 -do- bottom 4.18m 1615.00 Kgs
KSRB 12-5.7 : construction circular type manhole 1500mm internal dia 880.00 Kgs
KSRB 12-8.1: Extra for item No. KSRB 12-8.1 depth beyond 450mm 11.30 Kgs
KSRB 12-8.2 : constructing brick masonry inspection chamber 500x700mm and
450mm depth 96.00 Kgs
KSRB 12-8.2.1 : Extra for item No. KSRB 12-8.2 depth beyond 450mm and brick 12.30 Kgs
masonry
KSRB 12-8.3: Construction brick masonry inspection chamber 600x850mm and 120.00 Kgs
450mm depth
KSRB 12-8.3.1: Extra for item No. KSRB 12-8.3 depth beyond 450 mm and brick 14.20 Kgs
Providing and laying flooring with B.S. slab 10 cm thick on sand bed 7.5 cm to 8 cm 6.60 Kgs
thick
Providing and laying flooring with B.S. slab 10 cm thick on C.M. bed 1:6, 25mm thick
and pointed 13.40 Kgs
Providing andwith C.M.
laying 1:3 and steps machine cut granite slabs 40mm thick on
flooring
C.M. bed 1:6, - 25mm thick, and pointed with C.M. 1:3 over existing cc bed 8.80 Kgs
Providing and laying flooring and steps fine dressed granite 8.25 Kgs
-do- 7.55 Kgs
Flooring with 1:2:4cc 15.00 Kgs
Flooring with 1:2:4cc with red oxide 20.00 Kgs
Flooring 40mm thick with an underlay of 30mm thick cc1:2:4 20.00 Kgs
Metallic floor hardner 2.6 kg 18.50 Kgs
Metallic floor hardner 2.6 kg 25.00 Kgs
Tandoor blue slab 1.15 sqm, pigment 0.45 kg 13.00 Kgs
Shahabad slab 1.15 sqm, pigment 0.45 kg 13.00 Kgs
cudapa slab 1.15 sqm, pigment 0.45 kg 13.00 Kgs
marble chips 17.3 kgs, marble powder 0.0017 cum pigment 0.56 kgs 17.00 Kgs
marble chips - 17.3 kgs, marble powder - 0.0017cum, white cement - 0.16 kgs,
pigment 9.00 Kgs
Marble chips - 17.3 kgs, white cement 0.08 bags, marble powder - 0.0017 cum, 9.00 Kgs
pigment
marble chips - 17.3 kgs, white cement 0.16 kgs marble powder - 0.0017 cum 9.00 Kgs
mosaic tiles - 1.1 sqm, pigment - 0.30 kgs 15.50 Kgs
white cement - 0.08 bags, pigment - 0.30 kgs 11.00 Kgs
mosaic tiles - 1.1 sqm, white cement - 0.04 bags, pigment - 0.30 kgs 13.00 Kgs
white mosaic tiles - 1.10 sqm, white cement - 0.17 bags 6.50 Kgs
checkered mosaic tiles - 1.10 sqm, pigment - 0.3 kgs 15.00 Kgs
checkered mosaic tiles - 1.10 sqm, white cement - 0.088 bags, pigment - 0.3 kgs 11.00 Kgs
mosaic tiles - 1.10 sqm, white cement - 0.04 bags, pigment - 0.30 kgs 13.00 Kgs
mosaic tiles - 1.10 sqm, white cement - 0.17 bags 6.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
ceramic tiles - 1.10 sqm, white cement - 0.002 bags 9.50 Kgs
marble slabs - 1.15 sqm, white cement - 0.01 bags 11.00 Kgs
. 10.00 Kgs
red oxide - 0.28 kg 10.00 Kgs
glazed tiles - 46 nos. 9.00 Kgs
glazed tiles 46 nos. 9.00 Kgs
glazed tiles 46 nos. 9.00 Kgs
glazed tiles 46 nos. 9.00 Kgs
marble slab - 1.15 sqm 11.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.00 Kgs
Finishing Work 1.90 Kgs
Finishing Work 1.90 Kgs
Finishing Work 0.75 Kgs
Finishing Work 0.75 Kgs
Finishing Work 6.50 Kgs
Finishing Work 4.90 Kgs
Finishing Work 3.00 Kgs
Finishing Work 8.00 Kgs
Finishing Work 6.00 Kgs
Finishing Work 4.00 Kgs
Finishing Work 10.00 Kgs
Finishing Work 7.50 Kgs
Finishing Work 4.95 Kgs
Finishing Work 11.00 Kgs
Finishing Work 8.00 Kgs
Finishing Work 5.50 Kgs
Finishing Work 6.50 Kgs
Finishing Work 4.90 Kgs
Providing tough cement plastering cm 1:4 6.25 Kgs
Providing tough cement plastering cm 1:6 4.00 Kgs
Providing flooring coat of cement 1.40 Kgs
. 0.10 Kgs
Linseed oil 0.08 ltr. 0.10 Kgs
Marble chips - 0.87 kgs, marble powder - 0.0007 cum, pigment - 0.285 kgs 18.50 Kgs
White cement - 0.41 kg, Marble chips - 0.87 kgs, Marble powder - 0.0007 cum,
pigment - 0.285 kgs 15.00 Kgs
White cement - 0.04 bags, Marble chips - 8.7 kgs, Marble powder - 0.0007 cum, 17.00 Kgs
pigment - 0.28 kgs
White cement - 0.08 bags, Marble chips - 8.7 kgs, Marble powder - 0.0007 cum 15.00 Kgs
Mosaic tiles - 1.10 sqm 12.90 Kgs
Mosaic tiles - 1.10 sqm, pigment 0.462 kgs 12.90 Kgs
Mosaic tiles - 1.10 sqm, white cement - 0.066 bags, pigment 0.55 kgs 9.60 Kgs
Mosaic tiles - 1.10 sqm, white cement - 0.13 bags 6.00 Kgs
Repairs to Building 0.00110 Kgs
Repairs to Building 0.00110 Kgs
Repairs to Building 0.50 Kgs
Repairs to Building 10.20 Kgs
Repairs to Building 10.20 Kgs
Repairs to Building 7.60 Kgs
Repairs to Building 7.60 Kgs
Repairs to Building 5.00 Kgs
Repairs to Building 1.25 Kgs
Repairs to Building 10.00 Kgs
Repairs to Building 0.75 Kgs
Repairs to Building 0.50 Kgs
KSRRB M-600-1 : Construction of dry lean cement concrete mix M-5 160.00 Kgs
KSRRB M-600-2 : Construction of unreinforced, dowen jointed, plain cement
concrete pavement M-30 360.00 Kgs
KSRRB M-600-2 : Construction of unreinforced, dowen jointed, plain cement
concrete pavement M-40 420.00 Kgs
KSRRB M-600-3 : Construction of rolled cement concrete mix M7.5 OPC cement 180.00 Kgs
KSRRB M 600-5: Construction of base sub-base mix M5 OPC cement 160.00 Kgs
KSRRB M600-6. Construction of reinforced, dowel jointed, plain cement concrete 360.00 Kgs
pavement M30 pavement, construction of un-reinforced plain cement concrete
Cement concrete 360.00 Kgs
M-30
Cement concrete pavement, construction of un-reinforced plain cement concrete
M-20 300.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 1000mm dia piles - M20 320.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 1000mm dia piles - M30 360.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 1000mm dia piles - M35 390.00 Kgs
KSRRB 1100.2 Driving cast-in- place vertical RCC 500mm dia - M20 320.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 500mm dia piles - M30 360.00 Kgs
KSRRB 1100-1 Bored/cast in situ RCC 500mm dia piles - M35 390.00 Kgs
KSRRB M-1100-3.1 Bored cast-in-situ RCC Pile with OPC - M35 390.00 Kgs
KSRRB M1100-3.2 -do- B. Pile diametre = 1000mm- M35 390.00 Kgs
KSRRB M1100.3.3 -do- C.pile diametre = 1200 mm - M35 390.00 Kgs
KSRRB M1100-4.1 Driven cast-in-place vertical RCC Pile with OPC cement design mix
M35 390.00 Kgs
KSRRB - M1100-4.2 - DO- pile diametre = 1000mm 390.00 Kgs
KSRRB M1100-4.3 -do- pile diametre = 1200mm 390.00 Kgs
KSRRB M1100-4.4 - Driven precast vertical RCC piles with OPC cement design mix
M35 - file diametre = 500mm 390.00 Kgs
KSRRB M1100-4.5 -do- Pile diametre = 750mm M35 390.00 Kgs
KSRRB M1100-4.6 -Do- pile diametre = 1000mm M35 390.00 Kgs
KSRRB M-1100-4.7 Driven precast vertical RCC Piles with OPC cement deisgn mix 390.00 Kgs
M35 - size of pile = 300mm x 300mm
KSRRB M1100-4.8 -do- size of pile = 500mm x 500mm - M35 390.00 Kgs
KSRRB M1100-4.9 : -do- size of pile = 750mm x 750mm - M35 390.00 Kgs
KSRRB M1100-8.1: Cement Concrete for reinforced concrete in pile cap as per
drawing and technical specifcation complete A.RCC with OPC cement design M20 320.00 Kgs
KSRRB M1100-8.2 -do A. RCC with OPC cement design mix M-20 320.00 Kgs
KSRRB M1100-9.1 Cement concrete for reinforced concrete inm pile cap as per 340.00 Kgs
drawing and technical specifications - B RCC with OPC Cement design mix M25
KSRRB M1100-9.2 : -do- RCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1100-10.1 : Cement concrete for reinforcement concrete in pile cap per 360.00 Kgs
drawing and technical specification - C. RCC with OPC cement design mix M30
KSRRB M-1100-10.2 -do- C. RCC with OPC cement design mix M30 360.00 Kgs
KSRRB M1100-11.1 : Cement concrete for reinforced concrete in Pile Cap complete 390.00 Kgs
as per drawing - D. RCC with OPC cement design mix M35
KSRRB M1100-11.2 : -do- D. RCC with OPC cement design mix M35 390.00 Kgs
KSRRB M1100-12 Providing and laying of PCC M15 levelling course 100mm thick 240.00 Kgs
below
KSRRB M1200-3.1 i) RCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200.3.2 ii) -do- with M-25 340.00 Kgs
KSRRB
KSRRB M1200-3.3
M1200-4.1 iii)
: i) RCC
PCC with OPC
design mixcement design mix M35
M15 with 390.00 Kgs
OPC cement 240.00 Kgs
KSRRB M1200-4.2 ii) PCC with OPC cement design mix M20 300.00 Kgs
KSRRB M1200-4.3 iii) RCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200-4.4: iv) PCC with OPC cement design mix M25 340.00 Kgs
KSRRB M-1200-4.5 : v) RCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1200-4.6 vi) PCC with OPC cement design mix M30 360.00 Kgs
KSRRB M-1200-4.7 vii) RCC with OPC cement design mix M30 360.00 Kgs
KSRRB M1200-4.8 viii) RCC with OPC cement design mix M35 390.00 Kgs
KSRRB M1200-4.9 ix) RCC with OPC cement design mix M40 420.00 Kgs
KSRRB M1200-5.1 : Plain / Reinforced cement concrete, in well foundation
complete as per drawing and technical specification mix M20 320.00 Kgs
KSRRB M1200-5.2 : Plain / reinforced cement concrete, in well foundation complete 320.00 Kgs
as per drawing- M 20
KSRRB M1200-6.1: Plain/reinforced cement concrete, in well foundation complete 340.00 Kgs
ii) PCC with OPC cement design mix M25
KSRRB M1200-6.2: Plain / reinforced cement concrete, in well foundation complete 340.00 Kgs
mix
KSRRBM25M1200-7.1: Plain/ reinforced cement concrete, in well foundation design mix 360.00 Kgs
M30
KSRRB M1200-7.2 : Plain/ reinforced cement concrete, in well foundation complete
as per drawing design mixreinforced
M30 360.00 Kgs
KSRRB M1200-8.1: Plain/ cement concrete, in well foundation complete
as per drawing iv) PCC with OPC cement design mix M35 390.00 Kgs
KSRRB M1200-8.2: Plain/ reinforced cement concrete, in well foundation complete 390.00 Kgs
as per drawing and Techical specifcation PCC with OPC cement design mix M35
KSRRB M1200-9.1 (i) PCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200-9.2 (ii) PCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1200-9.2 (ii) PCC with OPC cement design mix M30 360.00 Kgs
E-Top Plug : KSRRB M1200-10.1 (i) i) PCC design mix M15 with OPC cement 240.00 Kgs
KSRRB M1200-10.2 : (ii) PCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200-10.3 : (iii) PCC with OPC cement design mix M25 340.00 Kgs
KSRRB M1200-10.4: (iv) PCC with OPC cement design mix M30 360.00 Kgs
KSRRB M1200-11.1 : Plain/reinforcement cement concrete, in well foundation
F.well cap i) RCC with OPC cement design mix M20 320.00 Kgs
KSRRB M1200-11.2 : Plain/reinforced cement concrete, in well foundation complete 320.00 Kgs
as per drawing and technical specification i) RCC with OPC cement design mix M20
KSRRB M1200-11.3 : Plain/reinforced cement concrete, in well foundation complete 320.00 Kgs
as per drawing and technical specification i) RCC with OPC cement design mix M20
KSRRB M1200-11.4 : Plain / reinforced cement concrete, in well foundation
complete as per drawing
KSRRB M1200-11.5 and
: Plain/ technicalcement
reinforced specification (ii) RCC
concrete, withfoundation
in well OPC cement design 340.00 Kgs
mix M25 as per drawing and technical specification (iii) RCC with OPC cement
complete 360.00 Kgs
KSRRB M1200-11.6 : Plain / Reinforced cement concrete, in well foundation
design mixasM30
complete per drawing and technical specification: RCC with OPC cement design 360.00 Kgs
KSRRB
mix M30M1200-11.7: Plain / Reinforced cement concrete, in well foundation
complete as per drawing and technical specification (iv) RCC with OPC cement 390.00 Kgs
design M1200-11.8:
KSRRB mix M35 Plain/ reinforced cement concrete, in well foundation complete 390.00 Kgs
as per drawing and technical specification:
KSRRB M1200-12. Plain/ reinforced cementRCC with OPC
concrete cement
in well design complete
foundation mix M35 as
per drawing and technical specification (v) RCC with OPC cement design 420.00 Kgs
KSRRB M1200-48.1 : Construction of cement concrete kerb with top andmix M40
bottom
width 115 and 165mm respectively 250mm high in M-20 grade PCC on M10 Grade 15.83 Kgs
KSRRB M1200-48.2 Construction of cement concrete kerb with top and bottom 15.83 Kgs
width 115
KSRRB M1200-49.1:
and 165mm Cast-in-Situ
respectively
cement
250mmconcrete
high inM20
M20kerbgrade
with
PCCchannel,
on M10
construction of cement concrete kerb with channel with top and bottom with 115 30.03 Kgs
and 165mm
KSRRB M1200-49.2. Cast-in-situ cement concrete M20 kerb with channel 30.03 Kgs
KSRRB M2100-10 Plain cement concrete M10 with OPC cement 220.00 Kgs
KSRRB M2100-11. Brick Masonry work in cement mortar 1:3 in foundation complete
excluding pointing and plastering 122.40 Kgs
KSRRB M2100-13: plain/reinforced cement concrete M15 with OPC cement 240.00 Kgs
KSRRB M2100-14 : Plain / reinforcement cement concrete M20 with OPC cement 300.00 Kgs
KSRRB M2100-15.1 : Plain/ Reinforcement cement concrete M-20 with OPC cement 320.00 Kgs
KSRRB M2100-15.2 : Plain/ reinforcement cement concrete M20 with OPC cement 320.00 Kgs
KSRRB M2100-16.1 Plain/ reinforced cement concrete design mix M25 with OPC 340.00 Kgs
cement
KSRRB M2100-16.2 : Plain / reinforced cement concrete idesign mix M25 with OPC 340.00 Kgs
cement
KSRRB M2100-17.1 : Plain/ reinforced cement concrete idesign mix M25 with OPC 340.00 Kgs
cement
KSRRB M2100-17.2 : Plain /reinforced cement concrete idesign mix M25 with OPC 340.00 Kgs
cdement
KSRRB M2100-8.1: Plain reinforced cement concrete in open foundation with OPC
cement design mix M30 360.00 Kgs
KSRRB M2100-18.2 : Plain / reinforced cement concrete in open foundation with
OPC cement design mix M30 360.00 Kgs
KSRRB M2100-19.1: Plain / reinforcement cement concrete in open foundation with 360.00 Kgs
OPC cement design mix M30
KSRRB M2100-19.2: Plain / reinforced cement concrete in open foundation with 360.00 Kgs
OPC cement design mix M30
KSRRB M2100-20.1 : Plain/ reinforcement in open foundation with OPC cement 390.00 Kgs
design mix M35
KSRRB M2100-20.2 : Plain/ reinforced cement concrete in open foundation with 390.00 Kgs
OPC cement design mix M35
KSRRB M2200-1 : Brick Masonry in 1:3 29.37 Kgs
KSRRB M2200-2 : Painting 1.53 Kgs
KSRRB M2200-3 : Plastering 7.34 Kgs
KSRRB M2200-4.1 :Stone Masonry in CM 1:3 168.30 Kgs
KSRRB M2200-4.2 : Coursed Rubble Masonry 153.00 Kgs
KSRRB M2200-4.3 : Ashlar Masonry 168.30 Kgs
KSRRB M2200-5.1 : M15 with OPC cement 240.00 Kgs
KSRRB M2200-5.2 : Design mix M20 with OPC cement 300.00 Kgs
KSRRB M2200-5.3 Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.4: Design mix M25 @ with OPC cement 340.00 Kgs
KSRRB M2200-5.5 : Design mix M25 with OPCcement 340.00 Kgs
KSRRB M2200-5.6 : Design mix M30 with OPCcement 360.00 Kgs
KSRRB M2200-5.7: Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.8 Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.9: Design mix M20 with OPC cement 320.00 Kgs
KSRRB M2200-5.10 - Design mix M20 with OPC cement 320.00 Kgs
KSRRB M2200-5.11: Design mix M20 with OPC cement 320.00 Kgs
KSRRB M2200-5.12 : Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.13: Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.14 : Design mix M25 with OPC cement 340.00 Kgs
KSRRB M2200-5.15: design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.16: Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.17: Design mix M30 with OPC cement 360.00 Kgs
KSRRB M2200-5.18 : Design mix M35 with OPC cement 390.00 Kgs
KSRRB M2200-5.19: Design mix M35 with OPC cement 390.00 Kgs
KSRRB M2200-5.20: Design mix M35 with OPC cement 390.00 Kgs
PCC grade M15 with OPC cement 240.00 Kgs
PCC grade M20 with OPC cement 300.00 Kgs
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete
M20 320.00 Kgs
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.1 : Furnishing and placing reinforced prestressed cement concrete 320.00 Kgs
M20
KSRRB M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in 320.00 Kgs
super
KSRRBstructure -M20
M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in
320.00 Kgs
super structure -M20
KSRRB M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in
super structure -M20 320.00 Kgs
KSRRB M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in 320.00 Kgs
super structure -M20
KSRRB M2300-1.2: Furnishing placing reinforced /Prestressed cement concretge in 320.00 Kgs
super
KSRRBstructure -M20
M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete 320.00 Kgs
in super structure - M20
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete
in super structure - M20 320.00 Kgs
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete
in super structure - M20 320.00 Kgs
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete 320.00 Kgs
in super structure - M20
KSRRB M2300-2.1: Furnishing and placing reinforced/Prestressed cement concrete 320.00 Kgs
in super structure - M20
KSRRB M2300-2.2: Furnishing and placing reinforced/prestrssed cement concrete in 320.00 Kgs
super
KSRRBstructure as per
M2300-2.2: drawingand
Furnishing andplacing
technical specifcations - M20cement concrete in
reinforced/prestrssed 320.00 Kgs
super structure as per drawing and technical specifcations - M20cement concrete in
KSRRB M2300-2.2: Furnishing and placing reinforced/prestrssed
super 320.00 Kgs
KSRRBstructure as per
M2300-2.2: drawingand
Furnishing andplacing
technical specifcations - M20cement concrete in
reinforced/prestrssed
super structure as per drawing and technical specifcations - M20 320.00 Kgs
KSRRB M2300-2.2: Furnishing and placing reinforced/prestrssed cement concrete in 320.00 Kgs
super structure as per drawing and technical specifcations - M20
KSRRB M2300-3.1 : Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-3.1 : Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-3.1
KSRRB structure -: M25
Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-3.1 : Furnishing and placing reinforced/ prestressed cement concrete
in superM2300-3.1
structure -: M25 340.00 Kgs
KSRRB Furnishing and placing reinforced/ prestressed cement concrete
in super structure - M25 340.00 Kgs
KSRRB M2300-3.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure as per drawing - M25
KSRRB M2300-3.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-3.2:
KSRRB structure as per drawing
Furnishing and-placing
M25 reinforced/ prestressed cement concrete
340.00 Kgs
in superM2300-3.2:
KSRRB structure as per drawing
Furnishing and-placing
M25 reinforced/ prestressed cement concrete
in super structure as per drawing - M25 340.00 Kgs
KSRRB M2300-3.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure as per drawing - M25
KSRRB M2300-4.1: Furnishing and Placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-4.1:
KSRRB structure -Furnishing
M25 and Placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-4.1: Furnishing and Placing reinforced/ prestressed cement concrete
in superM2300-4.1:
structure -Furnishing
M25 340.00 Kgs
KSRRB and Placing reinforced/ prestressed cement concrete
in super structure - M25 340.00 Kgs
KSRRB M2300-4.1: Furnishing and Placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure - M25
KSRRB M2300-4.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure M25
KSRRB M2300-4.2: Furnishing and placing reinforced/ prestressed cement concrete
in super structure M25 340.00 Kgs
KSRRB M2300-4.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in super structure M25
KSRRB M2300-4.2: Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-4.2:
KSRRB structure M25
Furnishing and placing reinforced/ prestressed cement concrete 340.00 Kgs
in superM2300-5.1:
KSRRB structure M25
Furnishing and Placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.1: Furnishing and Placing reinforced/ prestressed cement concrete
in super structure - M30 360.00 Kgs
KSRRB M2300-5.1: Furnishing and Placing reinforced/ prestressed cement concrete
in super structure - M30 360.00 Kgs
KSRRB M2300-5.1: Furnishing and Placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.1: Furnishing and Placing reinforced/ prestressed cement concrete 360.00 Kgs
in superM2300-5.2:
KSRRB structure -Furnishing
M30 and placing reinforced / prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.2: Furnishing and placing reinforced / prestressed cement concrete 360.00 Kgs
in superM2300-5.2:
KSRRB structure -Furnishing
M30 and placing reinforced / prestressed cement concrete
in super structure - M30 360.00 Kgs
KSRRB M2300-5.2: Furnishing and placing reinforced / prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-5.2: Furnishing and placing reinforced / prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-6.1: Furnishing and placing Reinforced/ Prestressed cement concrete 360.00 Kgs
in superM2300-6.1:
KSRRB structure as per drawing
Furnishing andM30
placing Reinforced/ Prestressed cement concrete
360.00 Kgs
in super structure as per drawing M30
KSRRB M2300-6.1: Furnishing and placing Reinforced/ Prestressed cement concrete
in super structure as per drawing M30 360.00 Kgs
KSRRB M2300-6.1: Furnishing and placing Reinforced/ Prestressed cement concrete 360.00 Kgs
in super structure as per drawing M30
KSRRB M2300-6.1: Furnishing and placing Reinforced/ Prestressed cement concrete 360.00 Kgs
in superM2300-6.2:
KSRRB structure as per drawing
Furnishing andM30
placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-6.2: Furnishing and placing reinforced/ prestressed cement concrete
in superM2300-6.2:
structure -Furnishing
M30 360.00 Kgs
KSRRB and placing reinforced/ prestressed cement concrete
in super structure - M30 360.00 Kgs
KSRRB M2300-6.2: Furnishing and placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M2300-6.2: Furnishing and placing reinforced/ prestressed cement concrete 360.00 Kgs
in super structure - M30
KSRRB M230-7.1: Furnishing and placing Reinforced/ prestressed cement concrete 390.00 Kgs
in superM230-7.1:
KSRRB structure Furnishing
as per drawing - M35 Reinforced/ prestressed cement concrete
and placing 390.00 Kgs
in super structure as per drawing - M35 Reinforced/ prestressed cement concrete
KSRRB M230-7.1: Furnishing and placing
in superM230-7.1:
structure Furnishing
as per drawing - M35 Reinforced/ prestressed cement concrete 390.00 Kgs
KSRRB and placing
in super structure as per drawing - M35 390.00 Kgs
KSRRB M230-7.1: Furnishing and placing Reinforced/ prestressed cement concrete 390.00 Kgs
in super structure as per drawing - M35
KSRRB M2300-7.2: Furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in super structure M35
KSRRB M2300-7.2: Furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in superM2300-7.2:
KSRRB structure M35
Furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in super structure M35
KSRRB M2300-7.2: Furnishing and placing reinforced/ prestressed cement concrete
in superM2300-7.2:
structure M35 390.00 Kgs
KSRRB Furnishing and placing reinforced/ prestressed cement concrete
in super structure M35 390.00 Kgs
KSRRB M2300-7.3: Furnishing and Placing Reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-7.3: Furnishing and Placing Reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-7.3:
KSRRB structure -Furnishing
M35 and Placing Reinforced/ Prestressed cement concrete
390.00 Kgs
in superM2300-7.3:
KSRRB structure -Furnishing
M35 and Placing Reinforced/ Prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-7.3: Furnishing and Placing Reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.1: Furniture and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-8.1:
KSRRB structure -Furniture
M35 and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.1: Furniture and placing reinforced/ Prestressed cement concrete
in superM2300-8.1:
structure -Furniture
M35 390.00 Kgs
KSRRB and placing reinforced/ Prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-8.1: Furniture and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.2: Furnishing and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.2: Furnishing and placing reinforced/ Prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-8.2: Furnishing and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.2: Furnishing and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-8.2:
KSRRB structure -Furnishing
M35 and placing reinforced/ Prestressed cement concrete 390.00 Kgs
in superM2300-8.3:
KSRRB structure -furnishing
M35 and placing reinforced/ prestressed cement concrete 390.00 Kgs
in superM2300-8.3:
KSRRB structure -furnishing
M35 and placing reinforced/ prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-8.3: furnishing and placing reinforced/ prestressed cement concrete
in super structure - M35 390.00 Kgs
KSRRB M2300-8.3: furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in super structure - M35
KSRRB M2300-8.3: furnishing and placing reinforced/ prestressed cement concrete 390.00 Kgs
in superM2300-9.1:
KSRRB structure -Furnishing
M35 and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M2300-9.1: Furnishing and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in superM2300-9.1:
KSRRB structure M40
Furnishing and placing reinforced/ Prestressed cement concrete
in super structure M40 420.00 Kgs
KSRRB M2300-9.1: Furnishing and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M2300-9.1: Furnishing and placing reinforced/ Prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M2300-9.2: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in superM2300-9.2:
KSRRB structure as per drawing
Furnishing andM40
placing reinforced/ prestressed cement concrete
420.00 Kgs
in super structure as per drawing M40
KSRRB M2300-9.2: Furnishing and placing reinforced/ prestressed cement concrete
in super structure as per drawing M40 420.00 Kgs
KSRRB M2300-9.2: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in super structure as per drawing M40
KSRRB M2300-9.2: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in superM2300-10.1:
KSRRB structure asFurnishing
per drawing M40
and placing reinforced/ prestressed cement 420.00 Kgs
concrete
KSRRB M2300-10.1: Furnishing and placing M40
in super structure as per drawing reinforced/ prestressed cement
concrete in super structure as per drawing M40 420.00 Kgs
KSRRB M2300-10.1: Furnishing and placing reinforced/ prestressed cement
concrete in super structure as per drawing M40 420.00 Kgs
KSRRB M2300-10.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure as per drawing M40
KSRRB M2300-10.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure as per drawing M40
KSRRB M2300-10.2: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure
KSRRB M2300-10.2: M40and placing reinforced/ prestressed cement
Furnishing 420.00 Kgs
concrete in super structure
KSRRB M2300-10.2: Furnishing M40and placing reinforced/ prestressed cement
concrete in super structure M40and placing reinforced/ prestressed cement 420.00 Kgs
KSRRB M2300-10.2: Furnishing
concrete in super structure M40 420.00 Kgs
KSRRB M2300-10.2: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure M40
KSRRB M230-10.3: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M230-10.3: Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in superM230-10.3:
KSRRB structure M40
Furnishing and placing reinforced/ prestressed cement concrete 420.00 Kgs
in super structure M40
KSRRB M230-10.3: Furnishing and placing reinforced/ prestressed cement concrete
in superM230-10.3:
structure M40 420.00 Kgs
KSRRB Furnishing and placing reinforced/ prestressed cement concrete
in super structure M40 420.00 Kgs
KSRRB M2300-11.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure as per drawing M40
KSRRB M2300-11.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure
KSRRB M2300-11.1: as per
Furnishing anddrawing
placing M40
reinforced/ prestressed cement
420.00 Kgs
concrete in super structure
KSRRB M2300-11.1: as per
Furnishing anddrawing
placing M40
reinforced/ prestressed cement
concrete in super structure as per drawing M40 420.00 Kgs
KSRRB M2300-11.1: Furnishing and placing reinforced/ prestressed cement 420.00 Kgs
concrete in super structure as per drawing M40
KSRRB M2300-11.2: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structrure
KSRRB M2300-11.2: as per
Furnishing anddrawing M45
placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structrure as per drawing M45
KSRRB M2300-11.2: Furnishing and placing reinforced/ Prestressed cement
concrete in super structrure as per 440.00 Kgs
KSRRB M2300-11.2: Furnishing anddrawing M45
placing reinforced/ Prestressed cement
concrete in super structrure as per drawing M45 440.00 Kgs
KSRRB M2300-11.2: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structrure as per drawing M45
KSRRB M2300-11.3: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structure M45
KSRRB M2300-11.3: Furnishing and placing reinforced/ Prestressed cement
concrete in super structure M45 440.00 Kgs
KSRRB M2300-11.3: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structure M45
KSRRB M2300-11.3: Furnishing and placing reinforced/ Prestressed cement 440.00 Kgs
concrete in super structure
KSRRB M2300-11.3: M45and placing reinforced/ Prestressed cement
Furnishing 440.00 Kgs
concrete in super structure
KSRRB M2300-12: FurnishingM45
and placing reinforced/ Prestressed cement concrete 450.00 Kgs
in
KSRRB M2300-12: Furnishing and M50
super structure as per drawing placing reinforced/ Prestressed cement concrete
in super structure as per drawing M50 450.00 Kgs
KSRRB M2300-12: Furnishing and placing reinforced/ Prestressed cement concrete
in super structure as per drawing M50 450.00 Kgs
KSRRB M2300-12: Furnishing and placing reinforced/ Prestressed cement concrete 450.00 Kgs
in super structure as per drawing M50
KSRRB M2300-12: Furnishing and placing reinforced/ Prestressed cement concrete 450.00 Kgs
in superM2300-13:
KSRRB structure as per drawing
Furnishing and M50
placing reinforced/ prestressed cement concrete 450.00 Kgs
in super structure M55
KSRRB M2300-13: Furnishing and placing reinforced/ prestressed cement concrete 450.00 Kgs
in superM2300-13:
KSRRB structure M55
Furnishing and placing reinforced/ prestressed cement concrete
in super structure M55 450.00 Kgs
KSRRB M2300-13: Furnishing and placing reinforced/ prestressed cement concrete 450.00 Kgs
in super structure M55
KSRRB M2300-13: Furnishing and placing reinforced/ prestressed cement concrete 450.00 Kgs
in super structure M55
KSRRB 2300-16: Providing and laying cement concrete wearing coat with OPC 360.00 Kgs
cement design mix
KSRRB M2500-2: M30 and laying of apron with cement concrete blocks of size
Providing
KSRRB M2500-4.2: providing and laying pitching on slopes laid over prepared filter 240.00 Kgs
0.5x0.5x0.5m
media includingM15
boulder apron laid dry in front of toe of embankment complete as
per drawing and technical specifications -do- B. Cement concrete Blocks of size 240.00 Kgs
KSRRB M2500-5.1: Providing and laying Flooring complete as per drawing and 168.30 Kgs
0.3x0.3x0.3m cast in cement
technical specifications concrete
laid over of grade
A. Rubble M-15
stone laid in cement mortar 1:3
KSRRB M2700-6: PCC M15 grade leveling course below approach slab complete as 240.00 Kgs
per drawing and technical specification complete as per specifications
KSRRB M2700-7: Reinforced cement concrete M30 approach slab 360.00 Kgs
KSRRB M2900-1: Plain cement concrete 1:3:6 mix with crushed 220.00 Kgs
KSRRb M300-6: Filling of crack using slow - curing bitumen emulsion and applying
crusher dust in case crack are wider 0.066 Kgs
KSRRB M2500-9 Curtain wall complete as per drawing and technical specifications. 153.00 Kgs
A stone masonry in cement mortar (1:3)
KSRRB M2500-10 Curtain wall complete as per drawing and Technical Specifications. 240.00 Kgs
B. Cement concrete Grade M-15
Repairs to Building 0.002 EACH
Repairs to Building 0.002 EACH
Repairs to Building 0.002 EACH
Repairs to Building 0.005 EACH
Repairs to Building 0.005 EACH
Repairs to Building 0.005 EACH
Repairs to Building 0.200 EACH
Repairs to Building 4.000 EACH
Repairs to Building 0.120 cum
Repairs to Building 0.120 cum
Repairs to Building 0.120 cum
Repairs to Building 0.00010 Metre.
Repairs to Building 0.00010 Metre.
KSRB 4.9.2: Providing T.M.T. steel reinforcement for RCC work 0.10750 Tonne
KSRB 4.9.2: Providing T.M.T. steel reinforcement for RCC work 0.10750 Tonne
KSRRB M1100-5: Driven vertical steel piles as per drawing = pile 400x250mm (ISHB 8.62800 Tonne
series)
KSRRB M1100-6: Driven vertical steel piles as per drawing = H section steel column 0.09716 Tonne
450x250mm (ISHB Series)
KSRRB M1100-13. Supplying, fitting and placing uncoated TMT bar reinforcement 1.050 Tonne
KSRRB M1100-13. Supplying, fitting and placing uncoated TMT bar reinforcement 1.050 Tonne
KSRRB M1100-14: Supplying, fitting and placing un-coated Mild steel reinforcement 1.050 Tonne
in foundation as per drawing
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m -Providing and fixing - 0.01150 Tonne
do- LWL in open foundation upto 3m
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m - do- below LWL in
open foundation beyond 3m 0.01150 Tonne
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m -do- for well 0.01150 Tonne
foundation below LWL upto 3m
Providing and fixing 3m long 25mm dia TMT dowel bars 1.5m -do- for well 0.01150 Tonne
foundation belowSupplying,
KSRRB M2200-6: LWL beyond 3m and placin
fitting 1.050 Tonne
TMT
KSRRB bar
M2200-6: Supplying, fitting and placin 1.050 Tonne
TMT bar
KSRRB M2200.7: Supplying, fitting and placing mild steel 1.050 Tonne
KSRRB M2300-14: Supplying, fitting and placing TMT bar reinforcement in super
structure complete 1.050 Tonne
KSRRB M2300-14: Supplying, fitting and placing TMT bar reinforcement in super 1.050 Tonne
structure complete
KSRRB M2300-15: High tensile steel wires/ strands including all accessories 1.020 Tonne
KSRRB M2700-2. Construction of precast RCC 0.01892 Tonne
railing of M-30 grade
21.7 0.00025 MT
21.9 0.00040 MT
21.10.2 0.00020 MT
21.11.1 0.068 MT
21.11.3 0.068 MT
21.11.5 0.068 MT
21.11.2 0.072 MT
21.11.4 0.072 MT
21.11.6 0.072 MT
21.12 0.003 MT
21.17.1 0.092 MT
21.17.3 0.092 MT
21.17.5 0.092 MT
21.17.2 0.103 MT
21.17.4 0.103 MT
21.17.6 0.103 MT
21.20.1 0.103 MT
21.20.3 0.103 MT
21.20.5 0.103 MT
21.20.7 0.103 MT
21.20.9 0.103 MT
21.20.11 0.103 MT
21.20.2 0.115 MT
21.20.4 0.115 MT
21.20.6 0.115 MT
21.20.8 0.115 MT
21.20.10 0.115 MT
21.20.12 0.115 MT
21.21.1 0.103 MT
21.21.3 0.103 MT
21.21.5 0.103 MT
21.21.7 0.103 MT
21.21.9 0.103 MT
21.21.11 0.103 MT
21.21.2 0.115 MT
21.21.4 0.115 MT
21.21.6 0.115 MT
21.21.8 0.115 MT
21.21.10 0.115 MT
21.21.12 0.115 MT
21.22.1 0.129 MT
21.22.3 0.129 MT
21.22.5 0.129 MT
21.22.2 0.141 MT
21.22.4 0.141 MT
21.22.6 0.141 MT
21.23.1 0.117 MT
21.23.3 0.117 MT
21.23.5 0.129 MT
21.23.7 0.129 MT
21.23.9 0.129 MT
21.23.11 0.129 MT
21.23.2 0.141 MT
21.23.4 0.141 MT
21.23.6 0.141 MT
21.23.8 0.141 MT
21.23.10 0.141 MT
21.23.12 0.141 MT
21.26 0.0012 MT
21.27 0.0010 MT
21.32 0.00146 MT
21.33 0.00146 MT
21.36 0.0022 MT
21.37 0.0022 MT
21.38 0.0019 MT
21.39 0.0019 MT
21.40 0.0022 MT
21.41 0.0022 MT
21.42 0.0019 MT
21.43 0.0019 MT
21.45.1 0.00098 MT
21.45.2 0.00068 MT
21.47 0.00582 MT
21.64 0.00121 MT
21.65 0.000858 MT
21.66 0.000527 MT
21.67 0.0009 MT
21.68 0.0011 MT
21.69 0.0015 MT
21.70 0.00105 MT
21.74.1 0.081 MT
21.74.2 0.081 MT
21.74.3 0.054 MT
21.74.4 0.054 MT
21.77.1 0.0955 MT
21.77.1 Waste Plastic 8.31 Kg
21.77.2 0.106 MT
21.77.2 9.23 Kg
21.78.1 0.119 MT
21.78.1 10.37 Kg
21.78.2 0.130 MT
21.78.2 11.31 Kg
21.79.1 0.136 MT
21.79.1 7.07 Kg
21.79.2 0.136 MT
21.79.2 7.07 Kg
KSRRB M2700-1: Providing and laying 12mm thick mastic asphalt wearing course on 0.00283 MT
top of deck slab
KSRRB M2800-2: Removal of existing asphaltic wearing coat comprising 0.0160 MT
KSRRB M2800-5.1: Sealing of cracks/porous concrete by injection 0.0011 MT
KSRRB 3000 Filling Potholes and Patch repairs with open graded premix surfacing, 0.00146 MT
20mm KSRRB M300-4
KSRRB 3000 Filling pot holes and patch repairs with Bituminous concrete 40mm 0.00459 MT
KSRRB M2100-8. Filling Annular Space Around Footing in Rock Lean cement
concrete
KSRRB M2700-2.
1:3:6 nominal
Construction
mix of precast RCC 0.00024 MT
railing of M-30 grade 0.03069 MT
21.5 0.0011 MT
21.6 0.0006 MT
21.55 0.1756 MT
21.56 0.1756 MT
21.70 0.0987 MT
21.71 0.153 MT
21.72 0.1865 MT
KSRRB 3000 Filling Potholes and Patch repairs with open graded premix surfacing, 0.00024 MT
20mm KSRRB M300-4
KSRRB 3000 Filling pot holes and patch repairs with Bituminous concrete 40mm 0.00024 MT
Linolium sheet 1.05 sqm, 1.05 Sqm
adhesive 0.20 kg 0.20 kgs
Metallic floor hardner 2.6 kg 2.60 kgs
Metallic floor hardner 2.6 kg 2.60 kgs
Shahabad slab 1.15 sqm, 1.15 Sqm
pigment 0.45 kg 0.45 kgs
pigment 0.45 kg 0.45 kgs
marble chips 17.3 kgs, 17.30 kgs
marble powder 0.0017 cum 0.0017 cum
pigment 0.56 kgs 0.56 kgs
marble chips - 17.3 kgs, 17.30 kgs
marble powder - 0.0017 cum, 0.0017 cum
white cement - 0.16 kgs, pigment 0.16 Kgs
Marble chips - 17.3 kgs, 17.30 Kgs
white cement 0.08 bags, 4.00 kgs
marble powder - 0.0017 cum, pigment 0.0017 cum
Marble chips - 17.3 kgs, 17.30 kgs
white cement 0.16 bags, 8.00 Kgs
marble powder - 0.0017 cum, pigment 0.0017 cum
Alluminium sheet for strips - 0.042 sqm 0.042 Sqm
Glass strips - 0.044 sqm 0.044 Sqm
mosaic tiles - 1.1 sqm, 1.10 Sqm
pigment 0.30 kgs 0.30 Sqm
white cement - 0.08 bags, 4.00 kgs
pigment - 0.30 kgs 0.30 Kgs
mosaic tiles - 1.1 sqm, 1.10 Sqm
white cement - 0.04 bags, 2.00 kgs
pigment - 0.30 kgs 0.30 kgs
white mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.17 bags 8.50 Kgs
checkered mosaic tiles - 1.10 sqm, 1.10 Sqm
pigment - 0.3 kgs 0.30 kgs
checkered mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.088 bags, 4.40 Kgs
pigment - 0.3 kgs 0.30 Kgs
mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.04 bags, 2.00 kgs
pigment - 0.30 kgs 0.30 kgs
mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement -0.17 bags 8.50 kgs
ceramic tiles - 1.10 sqm, 1.10 Sqm
ceramic tiles - 1.10 sqm, 1.10 Sqm
ceramic tiles - 1.10 sqm, 1.10 Sqm
ceramic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.002 bags 0.10 Kgs
white cement - 0.002 bags 0.10 Kgs
white cement - 0.002 bags 0.10 Kgs
white cement - 0.002 bags 0.10 Kgs
marble slabs - 1.15 sqm, 1.15 Sqm
white cement - 0.01 bags 0.50 Kgs
red oxide - 0.28 kg 0.28 kgs
glazed tiles - 46 nos. 46.00 Nos
Glazed tiles 46 nos. 46.00 Nos
Glazed tiles 46 nos. 46.00 Nos
Glazed tiles 46 nos. 46.00 Nos
marble slab - 1.15 sqm 1.15 Sqm
Water proof compound - 0.13 kgs 0.13 kgs
Water proof compound - 0.09 kgs 0.09 kgs
Water proof compound - 0.125 kgs 0.125 kgs
Water proof compound - 0.15 kgs 0.15 kgs
Water proof compound - 0.167 kgs 0.167 kgs
Water proof compound - 0.22 kgs 0.22 Kgs
Water proof compound - 0.167 kgs 0.167 Kgs
Lime - 0.0025/cum 0.0025 cum
burnt lime - 0.003 quintal 0.0030 Qtl
Burnt lime - 0.0015 quintal 0.0015 Qtl
Burnt lime - 0.003 quintal 0.003 Qtl
Burnt lime - 0.015 quintal 0.015 Qtl
Linseed oil 0.08 ltr. 0.08 ltr
Gopi - 0.025 kg, 0.025 kgs
Burnt lime 0.0015, 0.0015 Sqm
Gopi - 0.013 0.013 Kgs
Distemper - 0.081 ltr 0.081 ltr
Dry distemper - 0.1 kg, 0.10 kgs
whitening - 0.1 kg 0.10 Kgs
Dry distemper - 0.06 kg 0.06 kgs
Dry distemper - 0.04 kg 0.04 kgs
Distemper - 0.081 ltr, 0.081 ltr
oil bound - 0.15 kg 0.15 Kg
Oil bound - 0.1 kg 0.10 kg
Plastic emulsion paint - 0.12 ltr 0.12 ltr
Plastic emulsion paint - 0.073 ltr 0.073 ltr
Plastic emulsion paint - 0.049 ltr 0.049 ltr
Water proof cement paint - 0.3 kg 0.30 kg
Water proof cement paint - 0.18 kg 0.18 kg
Water proof cement paint - 0.12 kg 0.12 kg
White lead paint - 0.1 ltr 0.10 ltr
Pink Primer paint - 0.09 ltr 0.09 ltr
Aluminium paint primer - 0.1 ltr 0.10 ltr
Enamel primer - 0.09 ltr 0.09 ltr
Liquid wood filler - 0.075 ltr 0.075 ltr
Enamel metal paint - 0.15 ltr 0.15 ltr
Enamel metal paint - 0.15 ltr 0.15 ltr
Enamel metal paint - 0.09 ltr 0.09 ltr
Enamel metal paint - 0.09 ltr 0.09 ltr
Under coat flatting varnish - 0.07 ltr., 0.07 ltr
Varnish - 0.075 ltr 0.075 ltr
Varnish - 0.075 ltr 0.075 ltr
Varnish - 0.075 ltr 0.075 ltr
Spirit - 0.16 ltr, 0.16 ltr
Shellac - 0.024 kg, 0.024 kg
Linseed oil - 0.012 ltr, 0.012 ltr
pigment - 0.012 kg 0.012 kg
Spirit - 0.095 ltr, 0.095 ltr
Shellac - 0.013 kg, 0.013 Kg
Linseed oil - 0.007 ltr., 0.007 ltr
Bees wax - 0.05 kg, 0.05 Kg
Linseed oil - 0.036 ltr., 0.036 ltr
Varnish - 0.012 ltr 0.012 ltr
Bees wax - 0.25 kg, 0.25 kg
Linseed oil - 0.018 ltr., 0.018 ltr
Varnish - 0.06 ltr 0.06 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Ready mix primer paint - 0.09 ltr 0.09 ltr
Enamel metal paint - 0.15 ltr 0.15 ltr
Enamel metal paint - 0.09 ltr 0.09 ltr
Alluminium paint - 0.08 ltr 0.08 ltr
Alluminium paint - 0.046 ltr 0.046 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Black japan paint - 0.07 ltr 0.07 ltr
Ready mix primer paint - 0.084 ltr., 0.084 ltr
plaster of paris - 0.05 kg 0.05 kg
Wall paint - 0.11 ltr., 0.11 ltr
Wall paint - 0.65 ltr., 0.65 ltr
Ready mix primer paint - 0.148 ltr., 0.148 ltr
Ready mix primer paint - 0.09 ltr., 0.09 ltr
Wax polish - 0.01 kg 0.01 kg
Wax polish - 0.007 kgs 0.007 kgs
Marble chips - 0.87 kgs, 0.87 kgs
marble powder - 0.0007 cum, 0.0007 cum
pigment - 0.285 kgs 0.285 kgs
White cement - 0.41 kg, 0.41 kg
Marble chips - 0.87 kgs, 0.87 kgs
Marble powder - 0.0007 cum, 0.0007 cum
pigment - 0.285 kgs 0.285 kgs
White cement - 0.04 bags, 2.00 kgs
Marble chips - 8.7 kgs, 8.70 kgs
Marble powder - 0.0007 cum, 0.0007 cum
pigment - 0.28 kgs 0.28 kgs
White cement - 0.08 bags, 4.00 kgs
Marble chips - 8.7 kgs, 8.70 kgs
Marble powder - 0.0007 cum 0.0007 cum
Mosaic tiles - 1.10 Sqm 1.10 Sqm
Mosaic tiles - 1.10 Sqm, 1.10 Sqm
pigment 0.462 kgs 0.462 kgs
Mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.066 bags, 3.30 Kgs
pigment 0.55 kgs 0.55 kgs
Mosaic tiles - 1.10 sqm, 1.10 Sqm
white cement - 0.13 bags 6.50 Kgs
Nitric acid - 0.01 ltr / sqm 0.01 ltr
paint remover - 0.07 ltr/sqm, blow, lamp, brushes, 0.07 ltr
caustic soda - 0.073 kg/sqm, scraper, brushes, 0.073 kg
Kerosene oil - 0.10 ltr/sqm, scraper, putty at 5% on cost of kerosene oil 0.10 ltr
Kerosene oil - 0.10 ltr/sqm, scraper, putty at 5% on cost of kerosene oil 0.10 ltr
Paint remover - 0.07 ltr/sqm, brushes, scraper,terpentine oil, putty at 2% on 0.07 ltr
paint removal cost
Putty for filling holes-0.068 kg/metre 0.068 kg
Sl. Code Hire Charges Component Name
No. No.
1 1001 Mixer (concrete) - 1 cum Capacity
2 1002 Vibrator (with needle)
3 1004 Bitumen Boiler Oil Fired - 1500 ltr. Capacity
4 1005 Mini Mix Plant 6/10 TPH
5 1006 Wheel Burrows
6 1007 Hand Mixer
7 1008 Farm Tractor
8 1010 Mechanical Paver finisher 100 TPH capacity
9 1011 Tipper
10 1012 Front End Loader 1 cum bucket capacity
11 1013 Hot Mix Plant 40/60 TPH
12 1014 Vibrator Roller
13 1015 Hire charges for Tractor mounted or mini dozer
14 1016 Pneumatic Tyre Roller (8 Tonnes) - 25 cum / hr
15 1018 Motor Grader BEML
16 1019 Motorised scrapper
17 1020 Wheeled Dozer D 50 BEML
18 1022 Hydraulic Control Paver finisher (with Electronic S
19 1023 Tractor 40 HP
20 1024 Tractor 50 HP
21 1028 Wet Mix Plant 60 TPH/ Pug Mill
22 1030 Air Compressor
23 1031 J.C.B. Excavator
24 1032 Water Tanker / Day
25 1035 Road Roller 8-10 T ( 425Cum/day soil compacted)
Front end loader (1Cum) Turnover 120 Cum /day
26 1036 when used with hot mix plant
27 1037 Vibratory Roller 8 Tonne
28 1038 Pneumatic Road Roller
29 1039 Tandem Road Roller - 30 cum / hr
30 1040 Motor Grader 3.35 meter blade
31 1041 Motorised scraper (950 Cum / day)
32 1042 Wheeled Dozer (D50 BEML)
33 1043 Hot mix Plant ( 6-10TPH) 8T /hr capacity
34 1045 Hot mix plant 40-60 TPH Capacity
35 1046 Paver finisher Mechanical 100 TPH capacity
36 1047 Paver Finisher Hydrostatic with sensor control 100
37 1048 Tractor 40 HP
38 1049 Tractor 50 HP
39 1055 Air compressor (170 Cfm)
40 1056 Hydraulic Excavator 1 cum bucket
41 1057 Water Tanker
42 1058 Tractor mounted dozer
43 1059 Mixer (concrete small used in culvert)
44 1060 Vibrator
45 1063 Concrete pump 45 & 30 cum capacity
46 1064 nsit mixer 4.5 cum/hour
47 1065 Batching Plant (30 cum/hour)
48 1066 Batching Plant (15- 20 cum/hour)
49 1069 HOM for pumping water 3.5 KL / hr capacity pump
50 1070 HOM of Vibrator
51 1071 HOM of welding and grinding machine
52 1073 HOM of cutting and grinding machine
53 1074 HOM of cutting and grinding machine
54 1075 HOM of Machinaries for planing
55 1076 HOM of polishing machine
56 1077 HOM of Blow lamp
57 1078 HOM of pilling rig with Bentonite pump, etc.
58 1079 HOM of pump 23 KW
59 1080 HOM of pump 9.5 KW
60 1081 HOM of pneumatic hammer and pavement braker
61 1082 HOM of screed vibrator
62 1083 Mastic cooker
63 1084 HOM of gunniting equipment
64 1085 HOM of drilling equipment
65 1086 Plate vibrator having 3 Ton compaction force
66 1087 Crane charges
67 1088 Grout pump, agitator
68 1089 HOM of 7.5 cft capacity concrete mixing machine
69 1092 Crane Charges
70 1093 HOM of Machinery jack for prestressing
71 1094 HOM of spraying machine
72 1095 Crawlar Tractor
73 1096 Tipper-5 cum
74 1097 Smooth Wheeled Roller
75 1098 Rotavator - 25 cum / hr
76 1099 Ripper - 60 cum / hr
77 1301 Mechanical Broom Hydraulic
78 1302 Bitumen Pressure Distributor
79 1303 Emulsion Pressure Distrbutor
80 1304 Hotmix Plant - 120 TPH capacity
81 1305 Hotmix Plant - 100 TPH capacity
82 1306 Vacuum dewatering
83 1307 Hydraulic Chip Spreader
84 1308 Pot-hole Repair Machine
85 1309 GSB Plant 50 cum
86 1311 Cranes 80 tonnes
87 1312 Cranes 35 tonnes
88 1313 Cranes 3 tonnes
89 1314 Concrete Bucket - 1 cum capacity
90 1315 Kerb Casting Machine
91 1317 Piling Rig with Bantonite Pump
92 1321 Generator 100 KVA
93 1322 Generator 33 KVA
94 1324 Road Marking Machine
95 1325 Mobile Slurry Seal Equipment
96 135 Drilling Equipment (Tractor mounted)
97 1326 Integrated stone crusher of 200 TPH including belt
98 1327 Hot Mix Plant 20 to 40 TPH Capacity
99 1501 Grout pump with agitator & accessories
100 1503 Epoxy Injection gun
101 1506 Shotcreteing equipment
102 1511 Stressing jack with pump
103 1515 Hire charges for jack of 40 tonne lifting capacity
104 1517 Cement concrete batch mix at 75 cum/ hr
105 1527 Road sweeper at 1250 sqm/hr
Cement concrete batch mix at 175 cum/hor
106 1528 (effective output)
107 1529 Electric generator set 250 KVA
108 1530 Slip form paver with electronic sensor
109 1532 Concrete joint cutting machine
Batch type cold mixing plant 100 - 120 TPH
capacity producing an average output of 75 tonne
110 1535 per hour
111 1550 Motorised barge of 20 tonne capacity
112 1551 Boat to carry at least 20 persons
113 902 base mix plant (pug mill)
114 965 Transit mixer 4 cum capacity for lead beyond 1 km
Usage of plant & equipment for pneumatic method
115 970 of well sinking
Air Compressor 250 cfm with pneumatic breaker/
116 996 jack hammer along with accessories
Compressor with guniting equipment along with
117 999 accessories
118 137 Concrete paver finisher with 40 HP Motor
Unit Rate
RS. PS.
Day 1,600.00
Day 350.00
hr 157.00
Day 1,600.00
Day 15.00
Day 160.00
Day 2,260.00
Day 7,040.00
Day 2,016.00
hr 700
Day 76,960.00
Day 11,560.00
Day 2,400.00
Day 8,272.00
Day 15,200.00
Day 1,520.00
Day 14,000.00
Day 18,560.00
Day 1,520.00
Day 2,512.00
hr 1,133.00
Day 2,304.00
Day 6,720.00
Day 485.60
hr 433.00

hr 700.00
hr 1,300.00
hr 1,034.00
hr 1,034.00
hr 2,080.00
hr 190.00
hr 1,600.00
hr 375.00
hr 9,620.00
hr 880.00
hr 2,320.00
hr 190.00
hr 314.00
hr 290.00
hr 1,130.00
hr 61.00
hr 375.00
hr 50.00
hr 50.00
hr 194.00
hr 740.00
hr 1,850.00
hr 1,548.00
hr 50.00
Day 200.00
Day 400.0
Day 400.0
hr 50.00
cum 40.00
Day 200.00
Day 50.00
Day 37,960.00
Day 800.00
Day 500.00
hr 50.00
hr 50.00
Day 448.00
Day 400.00
Day 50.00
Day 300.00
Day 4,000.00
Day 300.00
Day 1,440.00
hr 500.00
hr 91.00
Day 75.00
hr 200.00
hr 240.00
hr 386.00
hr 14.55
hr 24.65
hr 309.00
hr 890.00
hr 665.00
hr 18,600.00
hr 13,750.00
Sq.mtr 40.00
hr 2,000.00
hr 852.00
hr 902.00
hr 971.00
hr 647.00
hr 270.00
hr 12.30
hr 280.00
hr 4,745.00
hr 630.00
hr 296.00
hr 67.30
hr 802
Day 1,920.00
hr 13,150.00
hr 4,580.00
hr 800.00
hr 275.00
hr 100.00
hr 150.00
No. 3,300.00
hr 1,800.00
hr 276.00

hr 7,904.00
hr 750.00
hr 1,800.00
hr 1,565.00

hr 8,000.00
hr 500.00
hr 110.00
hr 1,133.00
t.km 2.00

hr 400.00

hr 257.00

hr 257.00
hr 2,170.00

You might also like