Professional Documents
Culture Documents
Earth work for lowering and levelling the ground other than
foundation works by mechanical means upto 3.00 depth,
including providing shoring strutting and brasing, removal of
stumps and other deleterious matter, dressing of sides and
2.24 bottom, filling back the excavated earth to the extent cum 56
required & utilising/transporting the remaining earth upto
1.00 km lead. Including the cost of labour & HOM of
machineries, as per drawing and technical specification.
4.22 KSRB 4-3.1 : Extra if vibrator is used for Item No.4-1 to 4-8 cum 17
as per specifications. Specification No. KBS 4.2.6
4.23 KSRB 4-3.2 : Deduct where machine mixing is not done cum 17
Specification No. KBS 4.2.2.5 / 4.3.2.2
Providing and fixing RCC slabs 5 cms thick for wall shelves
with 12mm and down size jelly cement concrete design mix
4.55 M20 including CM 1:3 plaster finishing, curing etc., Sqm 548
complete (excluding the cost of steel and fabrication
charges
5.14 KSRB 5-5 : Extra lift charges for size stone masonry above cum 194
ground floor for every additional floor. KBS 5.1.13
5.20 KSRB 5-8.4 : Providing pulmane finish only on three line Sqm 355
dressed surface as per specifications. KBS 5.1.13
KSRB 7.2 : Providing and fixing 1mm thick M.S. sheet sliding
shutters with frame and diagonal braces of 40x40x6 mm
angle Iron 3.15mm thick M.S. Gusset plates at junctions and
corners, 25mm dia pulley, 40x40x6 mm angles and T iron
7.2 guide rail top and bottom respectively with handles, Sqm 3133
stoppers and locking arrangements etc., including applying
a priming coat of red lead paint cost of materials, labour,
HOM of machinery complete as per specifications. 1 double
leaf door of size 2.4x2.4m. Specification No. KBS 7.8 / 7.12
KSRB 7.3 : Providing and fixing 1mm thick M.S. sheet garage
door with frame and diagonal braces of size 40x40x6 mm
angle Iron, 3.15mm thick M.S. Gusset plates at the junctions
and corners, with handles, stoppers and locking
7.3 Sqm 2546
arrangements etc., including applying a priming coat of red
lead paint cost of materials, labour, HOM of machinery
complete as per specifications. Double leaf door of size
2.4x2.4m. Specification No. KBS 7.9 / 7.12
KSRB 7.4 : Providing and fixing 1mm thick M.S. sheet garage
door with frame and diagonal braces of size 40x40x6 mm
angle Iron, using M.S. flats 30x6 mm for diagonal braces and
central cross pieces 3.15mm thick M.S. Gusset plates at the
7.4 junctions and corners, with handles, stoppers and locking Sqm 2085
arrangements etc., including applying a priming coat of red
lead paint cost of materials, labour, HOM of machinery
complete as per specifications. 1 double leaf door of size
2.4x2.4m. Specification No. KBS 7.9 / 7.12
KSRB 7.5 : Providing and fixing pull and push type rolling
shutters of approved make out of 18 guage, 75mm wide
cold rolled steel laths of convex corrugation, with side
guides and bottom rail, with interlocking arrangements for
steel laths by means of alternate clips, suspension shaft
with High tension coil type springs two numbers, mounted
7.5 on specially designed pipe shaft, with bracket plates, guide Sqm 3086
channels, ball bearing arrangements, for inside & outside
locking with push & pull operations complete including
pulling hooks, 4Nos. handles with all fittings and
accessories, painted with a coat of red lead paint (without
top cover) cost of materials, labour, HOM of machinery
complete as per specifications. Shutter size 3mx2.8 m.
Specification No. KBS 7.10 / 7.12
KSRB 8.7-3 : Extra over item No. 8.7-1 and 8.7-2 for any
8.22 sunk or raised moulded design plaster of paris ( Gypsum Sqm 440
anhydrous ) ceiling
KSRB 8.7-4 : Extra over item No. 8.7-1 and 8.7-2 for
8.23 providing plaster of paris (Gypsum anhydrous ) ceiling Sqm/M 100
above 5 m height from floor level
KSRB 8.7-6 : Extra over item No. 8.7-5 for providing plaster
8.25 of paris (Gypsum anhydrous ) ceiling tiles above 5 m height Sqm/M 44
from floor level
Providing top layer with 12mm thick silica latex plaster with
8.26 smooth finishing on top surface. Sqm 360
Providing and fixing 6mm Bronze Multi wall poly carbonate
sheet for Tubular structure. The work including cost of all
8.27 materials, labour charges, and hire charges of machineries Sqm 2386
for cutting, welding, grinding and erection equipments,
complete as per specification.
9.105 Providing and fixing to the existing door frames, factory Sqm 2384
made single leaf HDF
Providing and fixing to the existing door frames, factory
made single leaf HDF skin sandwich composite door shutter
of 32 mm thickness made out of honeycomb of 26 mm thick
and surrounded by good quality properly seasoned wooden
reinforcements of size 25 mm X 65 mm for fixing fixtures
such as tower bolts, aldrops, handles etc., and laminated on
either sides with 3 mm thick wood grain finish good quality
HDF skins, using structural bonding material compatible
with honeycomb core, wood and HDF skin and the whole
assembly is bonded together at high temperature and
9.106 pressure using 650 tonnage heated compression moulding Sqm 1610
press. The HDF Composite door surface is coated with 2
coats of high quality primer.The front and back surfaces of
the door shutter and all the four sides are painted with two
coats of high quality paint of any desired colour. The
material and process for manufacturing the door shall
confirm to RV-TIFAC composites design centre standards
and specification and the door shutters tested in
confirmation to IS4020-1994, including cost of all materials,
labour charges, HOM and machineries etc. complete but
excluding the cost of fixtures.
Providing and fixing to the existing door frames, factory
made single leaf HDF skin sandwich composite door shutter
of 32 mm thickness made out of honeycomb of 26 mm thick
and surrounded by good quality properly seasoned wooden
reinforcements of size 25 mm x 65 mm for fixing fixtures
such as tower bolts, aldrops, handles etc., and laminated on
either sides with 3 mm thick wood grain finish good quality
HDF skins, using structural bonding material compatible
with honeycomb core, wood and HDF skin and the whole
assembly is bonded together at high temperature and
9.107 pressure using 650 tonnage heated compression moulding Sqm 1854
press. The HDF Composite door surface is coated with 2
coats of high quality primer.The front and back surfaces of
the door shutter and all the four sides are painted with two
coats of high quality paint of any desired colour. The
material and process for manufacturing the door shall
confirm to RV-TIFAC composites design centre standards
and specification and the door shutters tested in
confirmation to IS4020-1994, including cost of all materials,
labour charges, HOM and machineries etc. complete but
excluding the cost of fixtures.
Extra for water proofing the inside surface of tanks (OHT &
UGT) - applying of modified polymers soft acrylic esters coat
10.5.3 Sqm 285
@0.40 kg/sqm in 2 coats including all labour charges tools
and equipments, all complete as per the specification.
KSRB 11-17.2 : Providing and fixing C.P. brass towel rail 600
mm length, 20mm dia with C.P brackets, fixed to wooden
12.46 cleats with C.P. brass screws including cost of materials, Unit 697
labour complete as per specifications.
Providing and fixing 7.5 cms to 15.00 cms dia NP grating 100
12.111 mm dia. Each 160
12.114.2 Cleaning the blockages of closets and soil pipes into working M 50
order without scaffolding
Cleaning the blockages of closets and soil pipes into working
12.114.3 M 20
order underground stone ware pipes
Providing and fixing for flooring 20mm thick gang saw water
cut telephonic black granite in CM 1:4 proportion with a
coat of rough plastering using CM 1:4, cut to required
shape, pattern with paper joints, finished with cement
mortar using white cement and colour pigments to match
14.59 Sqm 2392
the colour of slab making through jointing with sealant,
grooves in joints including cost of curing etc., complete
including cost and conveyance of all materials, labour for all
items of work, HOM of equipment etc., complete as per
specification
Providing and fixing for flooring 20mm thick gang saw water
cut sadarhalli gray granite in CM 1:4 proportion, cut to
required shape, pattern with paper joints, finished with
14.61.2 cement mortar using white cement and colour pigments to Sqm 1927
match the colour of slab making through jointing with
sealant, groves in joints including cost of curing - minimum
width of 900mm.
KSRB 15.15.4 : Extra over Item 15-15.3 for painting with one
15.52.2 coat plastic emulsion paint of approved brand and shade on Sqm 3
ceiling and / or sloping roof as per specifications.
KSRB 24-6 : Extra for KSRB 24-5 cleaning and washing the
old ceiling and / or sloping roof with soap, soda and water
16.2.2 Sqm 3
including cost of materials, labour, complete as per
specifications.
KSRB 24-8 : Extra for Item No. 24-7 cleaning and washing
the old plastered ceiling and / or sloping roof surface with
16.3.2 soap, soda, water including cost of materials, labour, Sqm 3
complete as per specifications.
KSRB 24-43 : Add from Item no. 24-40 for every 5mm thick
increase after 10mm with respective mortars including
16.35.2 curing cost of materials, labour, complete as per Sqm 46
specifications.
KSRB 24-43 : Add from Item no. 24-40, 24-41, 24-42 for
16.36.2 every 5mm thick increase after 10mm with respective Sqm 40
mortars including curing cost of materials, labour, complete
as per specifications.
KSRB 24-43 : Add from Item no. 24-40, 24-41, 24-42 for
every 5mm thick increase after 10mm with respective
16.37.2 mortars including curing cost of materials, labour, complete Sqm 34
as per specifications.
KSRB 24-44 : Repairs to plaster in patches of 2.5 sqm and
less in walls, ceilings 10 to 20mm thick in cement mortar 1:3
including cutting the patches in proper shape and
16.38 replastering the surface of the wall including disposal of Sqm 243
rubbish with a lead of 50m including curing cost of
materials, labour, complete as per specifications.
Specification No.KBS 24.2.1
19.85 M 149
21.68 Sqm 69
KSRRB M500-57.3. Providing and laying a single coat of a
stress absorbing membrane over a cracked road surface,
with crack width above 9 mm and cracked area above 50%
after cleaning with a mechanical broom, using modified
binder complying with clause 521, sprayed at the rate of 15
kg per 10 sqm and spreading 11.2 mm crushed stone
21.69 Sqm 87
aggregates at 0.12 cum per 10 sqm, sweeping the surface
for uniform spread of aggregates and surface finished to
conform to clause 900.2 complete as per specification. Case
- III :Stress absorbing membrane (SAM) crack width above 9
mm and cracked aread above 50% MORTH Specification No.
522
Trail Bores : Drilling 76mm dia (NX) core hole in soft rock
using diamond core bit vertical or inclined up to 10 degree
to vertical, as directed in- cluding cost of materials,
machineries, labour, water charges, collection of core
25.30 M 2803
samples, logging and leaving, supplying honne wood core
box including cement grounding (excluding cost of cement
for grouting) and re-drilling in case of collapse of sides etc.,
complete.
KSRRB M1200-3.2 ii) RCC with OPC cement design mix M25
@ 340kgs, with 20mm and down size graded granite metal
26.5.2 coarse aggregates @0.7cum and fine aggregates @ cum 7310
0.47cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008
KSRRB M1200-4.2. ii) PCC with OPC cement design mix M20
@ 300kgs, with 40mm and down size graded granite metal
26.5.5 coarse aggregates @0.64cum and fine aggregates @ cum 6087
0.43cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008
KSRRB M1200-4.4. iv) PCC with OPC cement design mix M25
@ 340kgs, with 40mm and down size graded granite metal
26.5.7 coarse aggregates @0.7cum and fine aggregates @ cum 6672
0.47cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008
KSRRB M1200-4.5. v) RCC with OPC cement design mix M25
@ 340kgs, with 20mm and down size graded granite metal
26.5.8 coarse aggregates @0.7cum and fine aggregates @ cum 6724
0.47cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008
KSRRB M1200-4.6. vi) PCC with OPC cement design mix M30
@ 360kgs, with 40mm and down size graded granite metal
26.5.9 coarse aggregates @0.69cum and fine aggregates @ cum 6842
0.46cum, with superplastisiser @3lts confirming to IS9103-
1999 Reaffirmed-2008
KSRRB M1200-9.1. (i) PCC with OPC cement design mix M20
@ 320kgs, with 40mm and down size graded granite metal
coarse aggregates @0.69cum and fine aggregates @
26.14 0.46cum, with superplastisiser @3lts confirming to IS9103- cum 5699
1999 Reaffirmed-2008 Same as in bottom plug concrete,
excluding cost of forming sump, protective bunds, chiselling
etc.MORTH Specification No.1200,1500 & 1700
D. Intermediate Plug - Plain / Reinforced Cement Concrete,
in Well Foundation MORTH Specification No.1200,1500 &
1700 - KSRRB M1200-9.2. (ii) PCC with OPC cement design
26.15.1 mix M25 @ 340kgs, with 40mm and down size graded cum 6232
granite metal coarse aggregates @0.7cum and fine
aggregates @ 0.47cum, with superplastisiser @3lts
confirming to IS9103-1999 Reaffirmed-2008
27.4 cum 49
27.5 cum 56
27.6 cum 68
KSRRB M2100- Excavation in Ordinary Rock with blasting
KSRRB M2100-3.1. Earth work in excavation for foundation
of structures as per drawing and technical specifications,
27.7 including setting out, construction of shoring and bracing, cum 175
removal of stumps and other deleterious matter, dressing
of sides and bottom and backfilling with approved material
complete as per specifications.
27.8 cum 61
27.16 KSRRB M2100-8. Filling Annular Space Around Footing in cum 5340
Rock Lean cement concrete M 10 mix.
KSRRB M2100-9. Sand Filling in Foundation Trenches as per
27.17 Drawing & Technical SpecificationMORTH Specification No. cum 2133
304
37.12 Repairing door and window frames with available wood to Sqm 417
the required size.
Repairing and fixing shutters (panelled or glazed) to doors,
37.13 Sqm 417
windows, ventilators and cupboards.
37.14 Fixing old eve board with necessary screws and approved M 16
painting two coats.
Providing and fixing plain rolled glass 3mm thick with T.W
37.15 Sqm 706
beading of 10mm thick.
Providing and fixing 4mm thick glass panes to steel windows
37.16 including T.W. beading of 10 mm thick and 2 coats of Sqm 920
approved paints.
37.17 Easing of shutters of door. No 53
37.18 Easing of window shutters. No 52
Providing and fixing M.S bars to windows and ventilators
37.19 including cutting making holes in frame work with two coats kgs 106
of approved paints.
37.22 Removing cuddappa slab flooring and stacking the material Sqm 31
with a lead of 50 meters.
Removing and resetting Mangalore tiles and replacing
37.23 broken ones wherever necessary (excluding cost of new Sqm 16
tiles).
37.24 Cleaning glass with chemicals. Sqm 10
37.25 Removing and refixing existing mortar and pestle stone. Each 164
37.30 Providing wall black boards in CM 1:3 with two coats of Each 850
black paint including finishing etc., complete.
37.31 Providing and fixing mortise locks heavy duty to doors. No 588
37.36.2 Wall bores in size stone masonry - - upto 60 to 90cm thick. Each 203
37.36.3 Wall bores in size stone masonry - - upto 90 to 120 cm thick. Each 234
37.42.1 Dismantling Mangalore tiles roof and stacking the material Sqm 47
within a radius of 50 meters. - - with reepers
37.73.1 Providing shahabad stone flooring set in CM 1:8 with Sqm 737
cement pointing 1:3 proportion etc complete 40mm thick
37.73.2 Providing shahabad stone flooring set in CM 1:8 with Sqm 690
cement pointing 1:3 proportion etc complete 50mm thick
Providing and fixing RCC precast fencing pole of size 0.23m
x 0.23m x 2.0m casted in CC 1:1.5:3 with 20mm downsize
aggregate making holes for drawing barbed wire at 30cm
c/c using 10 mm dia vertical 4 TMT steel rods and 8mm dia
stirrups at 15cm c/c fixed 1.5m above ground level using
37.74 steel moulding, curing, transportation to work spot Each 1579
including excavation in hard soil fixing in plain cement
concrete 1:2:4 using 20mm downsize aggregate including
aligning to plumb and line providing including cost of all
materials, labour, hire charge of machineries lead, lift
loading & unloading etc.,Complete.
For roof slab & terraces Providing & applying water proofing
to roof slab, terraces, landscape area, podium etc., using
modified polyurethane cures (conforming to ASTM C836-
84) to give a tough elastomeric waterproof membrane on
the surface. The surface shall be cleaned free from dust and
38.2 other particle before usage. standards & methodology : This Sqm 700
compound has a medium viscosity grade with 620% of
elongation and shall be done either by roller
application/brush application/ spray. This will be applied for
a thickness of 1.3mm first layer 0.5mm & 2nd layer 0.8mm.
After applying the 2nd layer sand sprinkle shall be done to
provide mechanical key.
ISOPROOF SEALER Providing waterproof treatment to roof
slab using 2 coats of acrylic co polymer elastomeric
ISOPROOF sealer & protector. The surface shall be prepared
free of tar, dust, fungus, loose particles etc.,The surface
shall be applied with basecoat of crystallization liquid and
then ISOPROOF, wetting agent and liquid (1:1:6) over the
prepared surface. In addition the surface shall be provided
with polysulphide/ acrylic sealant to V groves, making
haunch at junction of parapet and roof slab and at damaged
portion using patching mortar to drain off rain water. Over
38.3 this one coat of flexible cementatious membrane (FCM), Sqm 985
Spreading 2 layers of 40 gsm non woven geotextile
membrane as reinforcing material (over FCM) with one
primer coat of ISOPROOF & applying second coat of
ISOPROOF liquid over the primer coat - conforming to ASTM
D 412 - 1992. The work shall be carried out as per the
directions of the Engineer in charge. standards &
methodology : 1. surface Preparation The surface shall be
made free from all dirt, fungus, loose particles by using wire
brush. The surface shall be cleaned with solvent like xylene,
Toluene, Benzene, dilute hydro chloric acid. i) Cutting of
38.24.1 _do_ copper and synthetic rope gabion of size 1mx1mx1m, Box 1300
aperture 100mm x 100mm
38.24.2 _do_ copper and synthetic rope gabion of size 1mx1mx2m, Box 2400
aperture 100mm x 100mm
_do_ copper and synthetic rope gabion of size 1mx1mx3m,
38.24.3 Box 3600
aperture 100mm x 100mm
Providing and Synthetic Biaxial Geogrid indigenously
manufactured from selected high tenacity synthetic yarn
with high molecular weight (> 25000 g/mol), and low
carboxyl end group (<30mmol/kg) for soil reinforcement
application for stabilisation, requirement of geogrid
strength in both direction with granular fill. Technical Data;
-do- ultimate tensile strenth 30Kn/m in MD and CMD,
Tensile strenth at 2% elongation 6Kn/m in MD and 6Kn/m in
CD, aperture size in MD and CD 26X26mm. -do- ultimate
tensile strenth 40Kn/m in MD and CMD, Tensile strenth at
2% elongation 7.5Kn/m in MD and 7.5Kn/m in CD, aperture
38.25
size in MD and CD 25X25mm -do- ultimate tensile strenth
60Kn/m in MD and CMD, Tensile strenth at 2% elongation
9Kn/m in MD and 7.5Kn/m in CD, aperture size in MD and
CD 25X25mm -do- ultimate tensile strenth 90Kn/m in MD
and CMD, Tensile strenth at 2% elongation 11Kn/m in MD
and 9Kn/m in CD, aperture size in MD and CD 23X23mm
Application Methodology; Biaxial geogrids are designed for
applications where strength requirement is in both
directions. They are used in reinforcement of granular
roadbase and subbase, area stabilization, trackbed
stabilization, load transfer platforms,etc.
38.38.2 WINDOWS : Centre fixed both side openable shutter 5 Sqm 4025
38.39.3 For 2 lane for formation width of 12mtrs. using SDBC mix Unit 44960
material.
38.40.1 For single lane for formation width of 7.50mtrs. and using Unit 32924
BC mix meterial.
Intermediate lane for formation width of 9.00mtrs using BC
38.40.2 Unit 36285
mix material.
38.40.3 2 lane for formation width of 12mtrs. using BC mix material. Unit 46745
Providing, laying, rumble strips, 250 mm wide and 25mm
height in rectangular shape at 1.00 mtr center to center for
the entire formation width of road using pre mix bituminous
material, including providing WBM (2 layers) for shoulder
38.41.1
portions, applying tack coat, providing 2 Nos. retro
reflective traffic signs as per IRC SP 67-2010 (for details IRC
99-1988) For 3 nos - including Wbm layers for length of 2
mtrs on either side of carriage way in shouldr portion.
38.44.7 Providing & fixing of glazed 3 Track - 2 Panel Sliding Door Sqm 7000
With Mesh
and also at important and salient locations, such as major
inter sections, Village / Town limits etc.,. The DGPS controls
will be so established that it meets the minimum criteria
specified for carrying out the mapping activities on a scale
of 1:5000 or 1:10000. (Inclusive of all taxes) NOTES: (a) The
DGPS control points established will be further extended
using the total station for densification so that there are
Control Points for every 200 m interval at staggered
locations. All Physical details shall be picked up for a width
of 50M from the center line on either side of the road.
Primary control points shall be a properly monumented
using Cement Concrete Pillar (RCC) of size 230 mm x 230
mm x 1250 mm, out of which 550 mm is embedded in
Cement Concrete below the ground level. All such Pillars
shall be serially numbered and painted in two coats of
Golden Yellow Colour. The X, Y, Z co-ordinates shall be
referred to center of the Pillar marked on top of it. The co-
ordinates shall be painted in red color. A list of all Primary
and Secondary control points with X,Y,Z Co-ordinate should
38.45 Km 36000
be submitted. Original Revenue Village Survey Maps will be
collected from revenue authorities and all the Control
Points shall be physically verified and marked on top of it.
(a. RTC and other information required shall be collected by
the Consultants from the appropriate authorities, b. Within
RoW, if there are any encroachments, then the consultant
shall get relevant records and prepare the relevant
documents for transferring RTC in the name of PWD.)
Cadastral (Revenue) Survey will be carried out in order to
demarcate the Right of Way of the road and also of all the
encroachments. A statement shall be prepared showing the
extent of Right of Way, Encroachment, including other
assets, Survey Number wise in standard format as approved
by PRAMC. The process carried out should be accurate
enough to issue the necessary notices to the encroachers
for getting them cleared. The following documents in both
Hard and Soft Copy (where required) should be furnished :
1. 1:4000 Drawings which includes, Details of SH, shall cause
to be marked on the map, thereon, Highway boundaries
Providing and fixing self-supported, ribbed, high quality,
high grade (D:350 MPA Yst Min ), pre- painted Galvalume
steel roof sheet, coated with bare Galvalume coating AZ
150, @ 150 gms/Smtr 55%AL,45%Zn) by hot dip process , of
total coated thickness as specified for different spans with a
tolerance of +/- 0.02 mm, according to technical
specification confirming to A 792, with NCCA ll-1, or ECCA
T4 Pencil hardness HB, NCCA standard T-Bend test. The roof
should be fastened to the gutter beam, on the external
sloping side, at an interval of 51mm Centre to Centre, to a
depth of 65 mm with GI anchor bolts and neoprene washers
& subjecting the gutter beam to Schmidt, Hammer test to
38.46
ensure the anchorage of the anchor bolts. The self-
supported roofing system should be designed to with stand
the wind load (As per IS 875 part-3) & Earthquake load (as
per IS 1893) & the design should also comply with any other
technical requirements such as turbo ventilators of 0.60
mts. dia and skylights of size 4.26 x 0.60 mts. fixed one in
each row @ 10.00 Mtr C/C along the length & hangers for
electrical fixtures as per the requirements including cost of
all materials &labour for erection, all lead and lift, loading
and unloading, HOM of machineries etc., complete as per
the standard detailed technical specification, design and
directions of the engineer in charge of the work.
38.47.2 do: - in low rainfall areas(One layers of under coat plus two Sqm 500
layers of top coat)
Light gauge steel frame structure (lgsfs) for dry wall panel
system Providing and fixing factory finished custom
38.60 designed structurally stable, corrosion resistant, cold Kg 174
formed wall structure, trusses, joists, purlins, connection
accessories etc., made out of 0.95 mm thick galvanized steel
coils, (AZ
providing and fixing with internal and external cement fibre
boards/ coir composite boards to lgsfs dry wall panel
system Providing and fixing for both external and internal
faces of Light Gauge Steel Frame Structure in two layers,
sandwiching a breathable vapour barrier in between layers
as per NBC code 2009, with external face having a 6mm
thick heavy duty fiber cement board/coir composite board
fixed on a 9mm thick heavy duty fiber cement board/coir
composite board confirming to IS 14862:2000, Category IV
type A or equivalent in standard sizes and internal face with
12.5mm thick gypsum plaster board/coir composite board
fixed on 8mm thick fiber cement board/coir composite
boards confirming to IS 14862:2000 of category III type B
38.61 (High pressure steam cured) or equivalent ,as per standard Sqm 3316
sizes with self drilling tapping screws half counter sunk, rib
head of 1.60mm to 4mm thick, 8 to 10 gauge, length
varying from 25 to 45mm / fasteners @ 600mm c/c of
approved make, with a staggered vertical joint of 2mm to
3mm sealed with a silicon based sealant and smooth
finished using fiber mesh tape and Epoxy and acrylic based
joining compound for seamless finish and the material and
process of manufacture and assembly/erection confirming
to RV-TIFAC Composite Designs and Specifications including
all costs of labour, materials, fabrication, assembling,
transportation, erection, incidental and unforeseen charges
complete as per the directions of the engineer in charge of
the work.
39.13.3 COURT HALL FURNITURE Horse Shoe Table Providing and Sqm 11000
fixing
39.16.1 X TYPE 4 wings 3A) Size : 1500 mmW x 1200mm D x 1200 No 56000
mm ht :
39.16.2 X TYPE 4 wings 3B) Size : 1500 mmW x 1500mm D x 1200 No 69500
mm ht:
T TYPE 2 wings 3C) Size : 1500 mmW x 1200mm D x 1200
39.16.3 No 35900
mm ht
39.16.4 T TYPE 2 wings 3D) Size : 1500 mmW x 1500mm D x 1200 No 53000
mm ht :
39.16.5 C TYPE 2 wings 3C) Size : 1500 mmW x 1200mm D x 1200 No 39100
mm ht:
C TYPE 2 wings 3D) Size : 1500 mmW x 1500mm D x 1200
39.16.6 No 57800
mm ht:
L TYPE one wing 3C) Size : 1500 mmW x 1200mm D x 1200
39.16.7 mm ht: No 23600
39.18.3 1200 mmW x 540mm D x 750 mm ht (Post formed table top No 8170
39.23.1 75mm thick frames tile based system (Frame with Tile) Sqm 5380
39.23.2 75mm thick frames tile based system (Frame with Glass) Sqm 5900
CO2 4.5Kg Squeeze grip Providing 4.5Kg CO2 Gas Type Fire
Extinugisher, Trolley Mounted, Easy Weight Management
used Unused Mechanism, Squeeze Grip, Gross Weight 19.1
Kg. empty Weight 14.6 Kg. Can Height 860MM Diameter
140MM, Discharge Time less than13 Secs, Controllable
40.34 discharge mechanism, Applicable on Class B&C Fire, B Each 18259
Rating 13B, Can Constuctin : Hot spinning/Forging, Valve
Construction : Forging & Machining, Internal Coating of
Can : Not Applicable, External coating of Can : Spray
Painting, Sheet metal thickness : 4.5MM ISI Approved, 1
Year Warranty. with instalert system with Superior quality
EPDM Rubber Hosepipe etc., complete
40.61 Wireless Siren Strobe External Wireless Siren - a fuly Each 14520
supervised Power Code
40.78 Supply installation, testing and commissioning of fire alarm Nos. 80000
Main panel with15 zone indication alaram etc. as required
Supplying Installing testing and commissioning approved
make Centrifugal pump end suction type couple to Electric
mortor of suitable HP, fitted on a common base frame and
rated for Fire duty. including 2 nos. Pressure guages fitted
40.79 on suction & delivery side of the pump. The pums shall run Nos. 288000
on 400/440V, 3ph, 50Hz electric supply, Duty of pumps:
2850 Lpm @ 70.0m Head. Control panel shall be per
specification stated in Item No.87. (Cost of control pannel is
not included)
Wraping and Galing of U/G pipe line work includes one coat
40.98.2 of anti corrossion paint (Black) and two coats of Bituminous M 250
cloth. -do- 150 mm dia. Complete
Wraping and Galing of U/G pipe line work includes one coat
40.98.3 of anti corrossion paint (Black) and two coats of Bituminous M 200
cloth. -do- 100 mm dia. Complete
Wraping and Galing of U/G pipe line work includes one coat
40.98.4 of anti corrossion paint (Black) and two coats of Bituminous M 150
cloth. -do- 80 mm dia. Complete
Supplying Installation testing and Commissiong of Micro
precess base Fire alram Control panel having power
regulation Circuit, which conner to 230 AC to @$V.D.C.
Indicating FIRE-FAULT, ISOLATION with Feather touch push
button switches, Test facility also with work test facility
40.99.1 Each 18000
arrangement, provided in the panel. All this electronic
circuits componets are assembled in M.S.16 gauge suitable
panel cabinet with glass Fraonted and locking arrangements
including cost of all mateials etc. -do- Make
Ravel/Golbe/Royale 12 Zone. complete
40.11 Providing and Fixing Fire force board size of 3 Each 2950
40.11 Supplying of four bucket stand alongwith buckets. Complete Each 1200
40.11 Supplying of two bucket stand alongwith buckets. Complete Each 630
40.12 Supplying of FIRST AID CHART with lamination. Complete Each 225