Professional Documents
Culture Documents
doc Page 1 of 2
DB A DB L
GH
DH
A DH
H
8
B B PA
B SP
J Technical data
Speed of material
Type
Frame Metal free Scanning sensitivity 1) without Weight
Detection coil
thickness
Fixing width
zone sensitivity loss2)
GLS SENSITY GENIUS+
Min. Max.
DH DB GH GB L ADH ADB B BPA BSP N MZ2 MZ1 ∅ Fe ∅V2A ∅ Fe ∅ V2A [kg]
[m/sec] [m/sec]
B B
GLS0075/0050 50 75 250 279 200 100 100 210 160 120 2 320 240 0.29 0.41 0.22 0.31 0.06 9.30 19
All dimensions in mm
1)
The specified sensitivity (sphere Ø in mm) is related to the centre of the aperture of the detector (most unfavourable position). The achievable sensitivity
within a product depends on its product effect (intrinsic conductivity caused by moisture, salt content etc.), the product temperature and environmental
influences. The detectability of metal particles are also determined by their nature, shape and position.
2)
Conveying speed: If exceeding or falling below the limits stated contact sales and service team.
MZ1 Metal free zone (static metal)
MZ2 Metal free zone (active metal)
J Standard design
Detection coil and control unit GENIUS+ (option SENSITY or PRIMUS) mounted at the detector head.
Scope of delivery:
(see data sheet control unit GENIUS+, SENSITY or PRIMUS)
Coil housing: Stainless steel 1.4301 (AISI 304), glass bead blasted; tunnel surface made of polypropylene (PP),
polystyrene (PS)
Control enclosure: Stainless steel 1.4301 (AISI 304), glass bead blasted
Type of protection: IP 65
J Special versions
Detector head cooling for product temperatures
...............................................................
above +80° C
IP 67 protection
Explosion-proof version ATEX