ULTRASONIC TESTING REPORT (STRUCTURAL)

(COMPLETED WELD TUBULAR / NON TUBULAR)


Project : NORTH MALAY BASIN (NMB) FOR HESS EXPLORATION & PRODUCTION Report No. : NMBPH3-TOP-ROI-STR-UT-00006
MALAYSIA B.V.
Client : HESS EXPLORATION & PRODUCTION MALAYSIA B.V. Procedure No. : NMB-WBGB-CST-NDE-50001
Contract : 4610005771 Material Type /Grade : Carbon Steel
Drawing No. : NMB-WBGB-STR-DRW-FAB-50118-4 Surface Condition : BRUSH AND CLEAN
Drawing Title : TOPSIDES CELLAR DECK PRIMARY FRAMING PLAN JOINT DETAILS - CD1_3 Calib./Ref. Block : V1 & V2 BLOCK
& CD1_4
Drawing Rev : 1 Acceptance Criteria : UT: AWS D1.1 Section 6.13.1
Flaw detector : EPOCH LTC Welding Process : FCAW-GS
Serial no. : 130813212 Joint Configuration : SINGLE BEVEL
Couplant : WALLPAPER PASTE Lamination Check : Y
PWHT AFTER/ BEFORE : NA Testing Code / Standard : UT: AWS D1.1/M
Date of Inspection : 29-Jul-2020
PROBES FREQUENCY SIZE PRE LEVEL SENSITIVITY TR.LOSS SCANNING RANGE
0 Deg 4 MHZ 10Ø mm 1st BWE to FSH dB N/A dB 2nd BWE to FSH dB 100 mm
45 Deg 4 MHZ 8x9 mm N/A dB N/A dB N/A dB N/A mm
60 Deg 4 MHZ 8x9 mm N/A dB N/A dB N/A dB N/A mm
70 Deg 4 MHZ 8x9 mm 51.9 dB N/A dB +14 dB 100 mm
SENSITIVITY SETTING : 1.5mm Ø SIDE DRILLED HOLE TO 80% F.S.H

EvaluationWeld Defect / Discontinuity


Length Tested (mm)
Weld Identification.

Thickness (mm)

Remarks
Results
Welder ID
Item No.

Tubular Non- Tubular

Indication Decibel Discontinuity

Prepared By Reviewed By Witnessed / Reviewed By (3rd Party) Witnessed / Reviewed By

Name : Name : Name : Name :


Position : Position : Position : Position :
Date : Date : Date : Date :

Page 1 of 3
ULTRASONIC TESTING REPORT (STRUCTURAL)
(COMPLETED WELD TUBULAR / NON TUBULAR)
Project : NORTH MALAY BASIN (NMB) FOR HESS EXPLORATION & PRODUCTION Report No. : NMBPH3-TOP-ROI-STR-UT-00006
MALAYSIA B.V.
Client : HESS EXPLORATION & PRODUCTION MALAYSIA B.V. Procedure No. : NMB-WBGB-CST-NDE-50001
Contract : 4610005771 Material Type /Grade : Carbon Steel
Drawing No. : NMB-WBGB-STR-DRW-FAB-50118-4 Surface Condition : BRUSH AND CLEAN
Drawing Title : TOPSIDES CELLAR DECK PRIMARY FRAMING PLAN JOINT DETAILS - CD1_3 Calib./Ref. Block : V1 & V2 BLOCK
& CD1_4
Drawing Rev : 1 Acceptance Criteria : UT: AWS D1.1 Section 6.13.1
Flaw detector : EPOCH LTC Welding Process : FCAW-GS
Serial no. : 130813212 Joint Configuration : SINGLE BEVEL
Couplant : WALLPAPER PASTE Lamination Check : Y
PWHT AFTER/ BEFORE : NA Testing Code / Standard : UT: AWS D1.1/M
Date of Inspection : 29-Jul-2020
PROBES FREQUENCY SIZE PRE LEVEL SENSITIVITY TR.LOSS SCANNING RANGE
0 Deg 4 MHZ 10Ø mm 1st BWE to FSH dB N/A dB 2nd BWE to FSH dB 100 mm
45 Deg 4 MHZ 8x9 mm N/A dB N/A dB N/A dB N/A mm
60 Deg 4 MHZ 8x9 mm N/A dB N/A dB N/A dB N/A mm
70 Deg 4 MHZ 8x9 mm 51.9 dB N/A dB +14 dB 100 mm
SENSITIVITY SETTING : 1.5mm Ø SIDE DRILLED HOLE TO 80% F.S.H

Attenuation Factor

Indication Rating

Depth from Surface


Reference Level
Indication Level
Indication Number

Transducer Angle

Angular Distance
Max Resp % DAC

Distance From X

Distance From Y
Length (mm)

Depth (mm)

Width (mm)

From Face

Length
Leg
a b c d
1 9 3714 15mm 350 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted

2 10 3714 15mm 350 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted

3 12 6399 15mm 350 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted

4 13 6399 15mm 350 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted

5 18 6399 15mm 690 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted

6 19 6399 15mm 690 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted

7 24 3714 15mm 650 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted
Prepared By Reviewed By Witnessed / Reviewed By (3rd Party) Witnessed / Reviewed By

Name : Name : Name : Name :


Position : Position : Position : Position :
Date : Date : Date : Date :

Page 2 of 3
ULTRASONIC TESTING REPORT (STRUCTURAL)
(COMPLETED WELD TUBULAR / NON TUBULAR)
Project : NORTH MALAY BASIN (NMB) FOR HESS EXPLORATION & PRODUCTION Report No. : NMBPH3-TOP-ROI-STR-UT-00006
MALAYSIA B.V.
Client : HESS EXPLORATION & PRODUCTION MALAYSIA B.V. Procedure No. : NMB-WBGB-CST-NDE-50001
Contract : 4610005771 Material Type /Grade : Carbon Steel
Drawing No. : NMB-WBGB-STR-DRW-FAB-50118-4 Surface Condition : BRUSH AND CLEAN
Drawing Title : TOPSIDES CELLAR DECK PRIMARY FRAMING PLAN JOINT DETAILS - CD1_3 Calib./Ref. Block : V1 & V2 BLOCK
& CD1_4
Drawing Rev : 1 Acceptance Criteria : UT: AWS D1.1 Section 6.13.1
Flaw detector : EPOCH LTC Welding Process : FCAW-GS
Serial no. : 130813212 Joint Configuration : SINGLE BEVEL
Couplant : WALLPAPER PASTE Lamination Check : Y
PWHT AFTER/ BEFORE : NA Testing Code / Standard : UT: AWS D1.1/M
Date of Inspection : 29-Jul-2020
PROBES FREQUENCY SIZE PRE LEVEL SENSITIVITY TR.LOSS SCANNING RANGE
0 Deg 4 MHZ 10Ø mm 1st BWE to FSH dB N/A dB 2nd BWE to FSH dB 100 mm
45 Deg 4 MHZ 8x9 mm N/A dB N/A dB N/A dB N/A mm
60 Deg 4 MHZ 8x9 mm N/A dB N/A dB N/A dB N/A mm
70 Deg 4 MHZ 8x9 mm 51.9 dB N/A dB +14 dB 100 mm
SENSITIVITY SETTING : 1.5mm Ø SIDE DRILLED HOLE TO 80% F.S.H

8 25 3714 15mm 650 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A Accepted

Prepared By Reviewed By Witnessed / Reviewed By (3rd Party) Witnessed / Reviewed By

Name : Name : Name : Name :


Position : Position : Position : Position :
Date : Date : Date : Date :