You are on page 1of 4

WATER LAYOUT DISTRIBUTION COMPUTATION

SERVICE PIPE GROUND FLOOR

Water Closet (WC)- 2 X 3 = 6

Lavatory (LAV)- 2 X 1 = 2

Kitchen Sink (K.S.)- 1 X 2 = 2

Hose Bibb (H.B)- 4 x 3 = 12

SHOWER (SHO)- 2 x 2 = 4

Total = 26 wsfu

Flow = 26 wsfu x 8 gals/min = 208 gals/min

Prob of Simul. Use = *using interpolation* = 36.36%

Probable Demand = 208 gals/min x 0.3636 = 75.63 gals/min

Thus, Service Pipe = 32 mm. dia PVC Pipe

Branch 1

HB – 1 x 3 = 3

Flow= 3 wsfu x 8 gals/min = 24gals/min

Branch 1 = Use 20mm dia. PVC pipe

Branch 2

HB- 1 x 3 = 3

SHO- 1 x 2 = 2

Lav- 1 x 1 = 1

WC- 1 x 3 = 3

Total= 9wsfu

Flow= 9 x 8 = 72gals/min

Branch 2= Use 25 mm dia. PVC Pipe


Branch 3

K.S- 1 x 2 = 2

Lav- 1 x 1 = 1

SHO- 1 x 2= 2

WC- 1 x 3 = 3

H.B.- 2 x 3 = 6

Total: 14wsfu

Flow = 14 x 8 = 112 gals/min

Branch 3= Use 32 mm dia. PVC Pipe

Riser 1, 2 3 4 = Use 25 mm dia. PVC Pipe

Branch 4

Bathtub – 1 x 2 = 2

Lav- 1 x 1 = 1

WC- 1 x 3 = 3

Total: 6wsfu

Flow = 6 x 8 = 48 gals/min

Branch 4 = Use 25 mm dia. PVC Pipe

Branch 5

Lav- 1 x 1 = 1

W.C.- 1 x 3 = 3

SHO- 1 x 2 = 2

H.B.- 1 x 3 = 3

Total= 9wsfu

Flow = 9 x 8 = 72 gals.min

Branch 5= Use 25 mm dia PVC Pipe


Branch 6

Lav- 1 x 1 = 1

W.C.- 1 x 3 = 3

Sho- 1 x 2 = 2

Total: 6wsfu

Flow = 6 x 8 = 48 gals/min

Branch 6 = Use 25 mm dia. PVC Pipe

Branch 7

Lav – 1 x 1 =1

W.C.- 1 x 3 = 3

H.B.- 1 x 3 = 3

Total: 7wsfu

Flow = 7 x 8 = 56 gals/min

Branch 7 = Use 25 mm dia. PVC Pipe

For Fixtures Pipe Diameter

For Lavatory – 1 x 8 = 8gals/min  Use 10 mm dia. PVC Pipe

For W.C.- 3 x 8 = 24 gals/min  Use 20 mm dia. PVC Pipe

For H.B.- 3 x 8 = 24 gals/min  Use 20 mm dia. PVC Pipe

For Shower- 2 x 8 = 16 gals/min  Use 13 mm dia. PVC Pipe

For Bathtub- 2 x 8 = 16 gals/min  Use 13 mm dia. PVC Pipe

For Kitchen Sink- 2 x 8 = 16 gals/min  Use 13 mm dia. PVC Pipe