You are on page 1of 2

SIMOVERT MASTERDRIVES Vector Control

Compact and Chassis Units


Recommended system components
for converters and inverters Compact and chassis units

Selection and ordering data


Nominal Converter Inverter Output sinusoidal filter1) Output reactor1)
power fmax. Pv Iron-core reactor Pv
rating max. fmax. = 300 Hz max.
kW Order No. Order No. Order No. Hz W Order No. W

Supply voltage 3-ph. 380 V to 480 V and DC voltage 510 V to 650 V DC


400 V fpulse = 6 kHz fpulse £ 3 kHz
2.2 6SE7016–1EA61 6SE7016–1TA61 6SE7016–1EA87–1FC0 400 150 6SE7016–1ES87–1FE0 80
3 6SE7018–0EA61 6SE7018–0TA61 6SE7021–0EB87–1FC0 400 200 6SE7021–0ES87–1FE0 80
4 6SE7021–0EA61 6SE7021–0TA61 6SE7021–0EB87–1FC0 400 200 6SE7021–0ES87–1FE0 80
5.5 6SE7021–3EB61 6SE7021–3TB61 6SE7021–8EB87–1FC0 400 250 6SE7021–8ES87–1FE0 95
7.5 6SE7021–8EB61 6SE7021–8TB61 6SE7021–8EB87–1FC0 400 250 6SE7021–8ES87–1FE0 95
11 6SE7022–6EC61 6SE7022–6TC61 6SE7022–6EC87–1FC0 400 300 6SE7022–6ES87–1FE0 110

3 15
18.5
6SE7023–4EC61
6SE7023–8ED61
6SE7023–4TC61
6SE7023–8TD61
6SE7023–4EC87–1FC0
6SE7024–7ED87–1FC0
400
400
400
500
6SE7023–4ES87–1FE0
6SE7024–7ES87–1FE0
130
190
22 6SE7024–7ED61 6SE7024–7TD61 6SE7024–7ED87–1FC0 400 500 6SE7024–7ES87–1FE0 190
30 6SE7026–0ED61 6SE7026–0TD61 6SE7027–2ED87–1FC0 400 600 6SE7027–2ES87–1FE0 130
37 6SE7027–2ED61 6SE7027–2TD61 6SE7027–2ED87–1FC0 400 600 6SE7027–2ES87–1FE0 130
45 6SE7031–0EE60 6SE7031–0TE60 6SE7031–0EE87–1FH0 200 450 6SE7031–0ES87–1FE0 190
55 6SE7031–2EF60 6SE7031–2TF60 6SE7031–5EF87–1FH0 200 600 6SE7031–5ES87–1FE0 220
75 6SE7031–5EF60 6SE7031–5TF60 (6SE7031–5EF87–1FH08)) 200 600 6SE7031–5ES87–1FE0 220
90 6SE7031–8EF60 6SE7031–8TF60 6SE7031–5EF87–1FH02) 200 600 6SE7031–8ES87–1FE0 300
110 6SE7032–1EG60 6SE7032–1TG60 6SE7031–8EF87–1FH03) 200 750 6SE7032–6ES87–1FE0 300
132 6SE7032–6EG60 6SE7032–6TG60 6SE7031–8EF87–1FH04) 200 750 6SE7032–6ES87–1FE0 300
160 6SE7033–2EG60 6SE7033–2TG60 6SE7032–6EG87–1FH05) 200 900 6SE7033–2ES87–1FE0 370
200 6SE7033–7EG60 6SE7033–7TG60 6SE7032–6EG87–1FH06) 200 900 6SE7033–7ES87–1FE0 380
250 6SE7035–1EK60 6SE7035–1TJ60 – 6SE7035–1ES87–1FE0 460
315 6SE7036–0EK60 6SE7036–0TJ60 – 6SE7037–0ES87–1FE0 620
400 6SE7037–0EK60 6SE7037–0TJ60 – 6SE7037–0ES87–1FE0 620
500 – 6SE7038–6TK60 – 6SE7038–6ES87–1FE0 740
630 – 6SE7041–1TK60 – 6SE7041–1ES87–1FE0 860
710 – 6SE7041–3TL60 – 7)

without interphase
transformer chassis
900 – 6SE7041–6TQ60 – 6SE7038–6ES87–1FE0 (2x) 740 (2x)
with interphase
transformer chassis
900 – 6SE7041–6TM60 – 6SE7038–6ES87–1FE0 (2x) 740 (2x)
without interphase
transformer chassis
1300 – 6SE7042–5TN60 – 7)

Attention!
Please observe foot notes 2 to 6.

1) See Engineering Information, Section 6, also ob- 4) Rated current of the units with sinusoidal filter 7) No reactor required. Maximum cable length
serve foot notes 2 to 6. due to derating at a pulse frequency of 6 kHz, 800 m shielded, 1200 m unshielded.
IS = 195 A.
2) Rated current of the units with sinusoidal filter 8) Rated current of the units with sinusoidal filter
due to derating at a pulse frequency of 6 kHz, 5) Rated current of the units with sinusoidal filter due to derating at a pulse frequency of 6 kHz,
IS = 140 A. due to derating at a pulse frequency of 6 kHz, IS = 110 A and therefore lower than for the units
IS = 236 A. with 55 kW (no derating at 6 kHz).
3) Rated current of the units with sinusoidal filter
due to derating at a pulse frequency of 6 kHz, 6) Rated current of the units with sinusoidal filter
IS = 158 A. due to derating at a pulse frequency of 6 kHz,
IS = 278 A.

3/52 Siemens DA 65.10 · 2003/2004


SIMOVERT MASTERDRIVES Vector Control
Dimension Drawings
Compact PLUS/compact and
chassis units · cabinet units Output reactors (iron)

a
a 26

H
H

H
H

h
h
h

DA65-5368a DA65-5369b
DA65-5367
T T
T

B
B

B
DA65-5370
a T

Fig. 49 Fig. 50 Fig. 51 Fig. 52

Output reactors for mounting on horizontal surfaces

DA65-5371a
Type Fig. No. B H T a h Weight n1 n2 d
approx.
kg
6SE7013–0ES87–1FE0 52 124 122 73 – – 1 42 – 1) M 4 2)

n1
6SE7015–0ES87–1FE0 52 148 139 78 – – 2.2 49 90 M 4 2) d
6SE7016–1ES87–1FE0 52 178 153 73 – 146 4.4 53 166 M 5 2)
6SE7016–2FS87–1FE0 52 267 221 107 – 204 14.5 77 249 M 6 2)
n2
6SE7021–0ES87–1FE0 52 178 153 88 – 146 5.5 68 166 M 5 2)
6SE7021–5FS87–1FE0 50 207 220 104 55 – 20 70.5 176.5 M6 Mounting hole
6SE7021–8ES87–1FE0 52 219 180 99 – 168 8 69 201 M 6 2)
6SE7022–6ES87–1FE0 52 219 180 119 – 181 9.2 89 201 M 6 2)
6SE7023–4ES87–1FE0 52 267 221 107 – 216 11 77 249 M 6 2)
6SE7024–7ES87–1FE0 51 197 220 104 69 103 20 70 176 M6
6SE7026–0HS87–1FE0 51 235 250 146 98 – 30 101 200 M8
6SE7027–2ES87–1FE0 49 267 221 107 77 206 11 77 249 M 6 2)
6SE7028–2HS87–1FE0 51 264 280 155 101 – 45 18 224 M8
6SE7031–0ES87–1FE0 49 267 221 107 77 206 17 77 249 M6
6SE7031–2HS87–1FE0 51 314 335 169 109 – 60 138 264 M8
6SE7031–5ES87–1FE0 51 197 220 128 81 100 25 94 176 M6
6SE7031–7HS87–1FE0 51 314 335 169 109 – 60 138 264 M8
6SE7031–8ES87–1FE0 51 281 250 146 98 119 30 101 200 M8
6SE7032–3HS87–1FE0 51 367 385 174 112 – 80 141.5 316.5 M 10
6SE7032–6ES87–1FE0 51 281 250 146 111 121 30 101 200 M8
6SE7033–2ES87–1FE0 51 311 280 155 114 139 45 118 224 M8
6SE7033–7ES87–1FE0 51 264 280 155 101 – 45 118 224 M8
6SE7035–1ES87–1FE0 51 310 280 155 106 150 45 118 224 M8
6SE7037–0ES87–1FE0 51 360 335 169 114 180 60 138 264 M8
6SE7038–6ES87–1FE0 51 410 385 174 127 210 80 141 316 M 10
6SE7022–2FS87–1FE0
6SE7023–4FS87–1FE0
6SE7024–7FS87–1FE0
50
51
51
207
197
197
220
220
220
128
104
128
66
72
81

114
93
25
20
25
94.5
70
128
176.5
176
176
M6
M6
M6
7
6SE7033–0GS87–1FE0 51 417 435 194 118 – 120 155.5 356.5 M 12
6SE7033–5GS87–1FE0 51 417 435 194 118 – 120 155.5 356.5 M 12
6SE7034–5GS87–1FE0 51 417 435 251 147 240 160 212.5 356.5 M 12
6SE7035–7GS87–1FE0 51 533 565 207 – – 170 170.5 411 M 10
6SE7036–5GS87–1FE0 51 533 565 235 – – 220 198.5 411 M 10
6SE7038–6GS87–1FE0 51 608 650 245 – – 280 195.5 471 M 12
6SE7041–1ES87–1FE0 51 420 380 233 160 255 100 203 316 M 10
6SE7041–2GS87–1FE0 51 608 650 310 240 385 310 213 470 M 12

1) Fixing hole in the center of the foot. 2) For any mounting position.

Siemens DA 65.10 · 2003/2004 7/19

You might also like