DYNAMIC BALANCING

OF BLOWERS
DECEMBER 2022
BACKGROUND
One of our client has called us urgently to
perform in-situ dynamic balancing for three
blowers of similar configuration which
shows significant increase in vibration
amplitudes after motor overhauling.

Site - A leading petrochemical facility in


Kuwait
Motor size - 100 hp
Blower directly mounted on the Motor shaft
BLOWER 1 - VIBRATION DATA
Before Balancing After Balancing
Location Unit
21 Dec 2022 21 Dec 2022

M1H mm/sec rms 8.51 1.38

M1P G-s Peak 0.12 0.05

M1V mm/sec rms 6.6 0.98 ▪ Mass added: 62 grams


M1A mm/sec rms 18.49 0.86

M2H mm/sec rms 6.57 1.03

M2P G-s Peak 0.07 0.02

M2V mm/sec rms 6.42 0.92

M2A mm/sec rms 18.61 0.77


BLOWER 1 - FFT SPECTRUMS
BLOWER 2 - VIBRATION DATA
Before Balancing After Balancing
Location Unit
20 Dec 2022 21 Dec 2022

M1H mm/sec rms 7.5 3.5

▪ Mass added: 45 grams


M1P G-s Peak 0.08 0.05

M1V mm/sec rms 4.65 1.74

M1A mm/sec rms 17.52 2.6

M2H mm/sec rms 8.58 1.61

M2P G-s Peak 0.09 0.06

M2V mm/sec rms 7.75 0.58

M2A mm/sec rms 17.78 1.88


BLOWER 2 - FFT SPECTRUMS
BLOWER 3 - VIBRATION DATA
Before Balancing After Balancing
Location Unit
21 Dec 2022 21 Dec 2022

M1H mm/sec rms 32.86 0.67

M1P G-s Peak 0.03 0.04


▪ Mass added: 60 grams
M1V mm/sec rms 8.28 0.84

M1A mm/sec rms 21.36 0.91

M2H mm/sec rms 10.76 1.11

M2P G-s Peak 0.03 0.03

M2V mm/sec rms 14.03 0.84

M2A mm/sec rms 18.74 1.0


BLOWER 3 - FFT SPECTRUMS
BALANCING MASS ADDED