Professional Documents
Culture Documents
Line Diagram:
As per ISO 10816 Standards, the health status of the equipment is in Normal condition
Interpretation
having maximum vibration velocity (Vrms) is recorded as 2.16 mm/sec at G/B G2
axial.
There are no significant peaks perceptible in the spectrum. This is considered to be
Analysis
normal.
Recommendation
Please continue the usual operation.
G/B GENERATOR
G1 G2 G3 G4 DE NDE
Horizontal (mm/sec) 1.20 1.00 0.78 0.83 0.29 0.26
Vertical (mm/sec) 1.03 1.15 0.82 0.76 0.49 0.17
Axial (mm/sec) 1.59 2.14 2.30 1.26 0.37 0.27
Acceleration (g) 0.45 0.44 0.39 0.29 0.11 0.04
Temperature(°C) 65 64 66 62 34 35
Following vibration measurement recorded on 28.08.2020 in coupled condition of the equipment.
G/B GENERATOR
G1 G2 G3 G4 DE NDE
Horizontal (mm/sec) 0.82 0.93 0.94 0.88 0.32 0.59
Vertical (mm/sec) 0.81 0.84 0.79 0.44 0.31 0.18
Axial (mm/sec) 1.59 2.16 2.12 1.09 0.26 0.26
Acceleration (g) 0.33 0.33 0.47 0.32 0.06 0.05
Temperature(°C) 67 65 58 61 47 48
Machine Condition Report
1.8 to 3.1 mm/sec 2.8 to 5.1 mm/sec 4.5 to 7.1 mm/sec 7.1 to 11.2 mm/sec 11.2 to 18.0 mm/sec Marginal
7.1 to 11.1
3.1 to 4.5 mm/sec 5.1 to 7.1 mm/sec 11.2 to 18.0 mm/sec 18.0 to 28.0 mm/sec Caution
mm/sec
Above 7.1 Above 11.1
Above 4.5 mm/sec Above 18.1 mm/sec Above 28 mm/sec Critical
mm/sec mm/sec