You are on page 1of 2

PO Box 3146 Umina Beach, NSW 2257, Australia

Phone +61-(0)-400 088 662


Email info@aquation.com.au
www.aquation.com.au

Handheld Fluorometer

Aquation’s Handheld Fluorometer and Portable Datalogger is designed for


measuring plant stress in the field (i.e. the effective quantum yield of
photochemistry; II). The Handheld design enables rapid one-handed
measurement of multiple samples; results can be viewed immediately and later
downloaded to PC for analysis.
Field
Features Aquation’s Handheld Fluorometer and
Studies
Portable Datalogger enables rapid repeated
• Measures II using multiple- stress measurement of multiple replicate
turnover saturating pulse method
leaves in situ.
(PAM)
• Includes PAR and leaf II is widely used as a measure of plant stress.
temperature measurements Rapid sequential measurement of multiple
Pollution
• Single-handed operation: trigger leaves is important for accurate representation Studies
activated measurement, thumb of plant stress. The one-handed design makes
activated leaf-clip measurement of many plants easily achieved by
• Water resistant sensor a single operator. Additional features include
the measurement of ambient irradiance (as
• Portable Datalogger will operate
for 12 hours and log all PAR), and leaf temperature during eachII
Plant Stress
measurements reading. Analysis
• Lightweight and portable: the Not only is the Portable Fluorometer useful for
system can be easily carried and field studies. With the easy-to-use operating
used in the field
software AquationDirect, the fluorescence
• Easy-to-use software with an sensor can be operated direct from a computer.
uncluttered interface
This opens the door to a multitude of plant Environmental
• Automated function when in stress tests that can be conducted on the bench Analysis
pass-thru mode: measurements under controlled environmental conditions.
can be made according to
program

See over for further detail.


PO Box 3146 Umina Beach, NSW 2257, Australia
Phone +61-(0)-400 088 662
Email info@aquation.com.au
www.aquation.com.au
Configuration and use

Handheld The Handheld Fluorometer is


connected to the Portable
Fluorometer Datalogger, which is slung over the
Specifications: shoulder.
• Excitation light 470 nm The Portable Datalogger enables
• Actinic & saturating lights – user interaction while in the field,
white LED and displays the results of each
• Far-red light for PSI excitation measurement. Different settings
735 nm can be stored and used for
different plant species if needed.
• PAR sensor: cosine corrected Portable Datalogger with High
2 sensor 400-700 nm The Handheld unit has a thumb Contrast backlit screen for use in
bright sunlight.
• Leaf temperature: infra-red operated clip used to open the leaf
sensor 5.5–14 m, emissivity clip for easy one-handed leaf
of 1, resolution to ± 0.5 C insertion; the cosine-corrected PAR
• Operating temperature: 0 °C sensor can be seen on the blue
to 45 °C stalk. Leaf temperature (not
• Storage temperature: -5 °C to shown) is measured close to the
60 °C area of measurement. All
• Power: 14.8V 2.6Ah
measurements are made virtually
rechargeable lithium ion simultaneously.
battery pack
The Fluorescence sensor can be
easily removed from the sample
holder clip and used on the bench PAR measurement using cosine
for a wide range of plant stress corrected 2 sensor.
tests. The pass-thru mode enables
operation direct via PC and
AquationDirect.
Software is easy to use graphical
user interface; fully flexible
functions enable a wide range of
settings and custom programs

Leaf temperature measurement


using IR technology.

Aquation Pty Ltd


ABN: 97 127 430 184
DUNS: 75 650 2930
www.aquation.com.au