GENERAL NOTES STEPS & LANDINGS

- THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE THE STABILITY
- STEP SIZES (OTHER THAN FOR SPIRAL STAIRS) TO BE:
(N.C.C 2019 & BUILDING REGULATIONS 2018) - RISERS (R) 190MM MAXIMUM AND 115MM MINIMUM
AND GENERAL WATER TIGHTNESS OF ALL NEW AND/OR EXISTING
STRUCTURES DURING ALL WORKS.
- GOING (G) 355MM MAXIMUM AND 240MM MINIMUM
- ALL MATERIALS AND WORK PRACTICES SHALL COMPLY WITH, BUT NOT - THE BUILDER AND SUBCONTRACTORS SHALL CHECK AND VERIFY ALL
- 2R + 1G = 700MM MAXIMUM AND 550MM MINIMUM
LIMITED TO THE BUILDING REGULATIONS 2018, THE NATIONAL DIMENSIONS, SETBACKS, LEVELS AND SPECIFICATIONS AND ALL OTHER
- 125MM MAXIMUM GAP TO OPEN TREADS
CONSTRUCTION CODE OF AUSTRALIA 2019 AND ALL RELEVANT RELEVANT DOCUMENTATION PRIOR TO THE COMMENCEMENT OF ANY
- ALL TREADS, LANDINGS AND THE LIKE TO HAVE NON SLIP FINISH OR
CURRENT AUSTRALIAN STANDARDS (AS AMENDED) REFERRED TO WORKS. REPORT ALL DISCREPANCIES TO THIS OFFICE FOR CLARIFICATION.
SUITABLE NON-SKID STRIP NEAR EDGE OF NOSING.
THEREIN. - INSTALLATION OF ALL SERVICES SHALL COMPLY WITH THE RESPECTIVE
- PROVIDE BALUSTRADES WHERE CHANGE IN LEVEL EXCEEDS 1000MM
- GLAZING INCLUDING SAFETY GLAZING SHALL BE INSTALLED TO A SIZE, SUPPLY AUTHORITY REQUIREMENTS.
ABOVE THE SURFACE BENEATH LANDINGS, RAMPS AND/OR TREADS.
TYPE & THICKNESS SO AS TO COMPLY WITH; - THE BUILDER AND SUBCONTRACTOR SHALL ENSURE THAT ALL STORMWATER
BALUSTRADES (OTHER THAN TENSIONED WIRE BALUSTRADES) TO BE:
- N.C.C PART 3.6 FOR CLASS 1 AND 1O BUILDINGS WITHIN ADESIGN DRAINS, SEWER PIPES AND THE LIKE ARE LOCATED AT A SUFFICIENT
- 1000MM MIN. ABOVE FINISHED SURFACE LEVEL OF BALCONIES,
WIND SPEED OF NOT MORE THAN N3, AND DISTANCE FROM ANY BUILDINGS FOOTING AND/OR SLAB EDGE BEAMS SO
LANDINGS OR THE LIKE, AND
- N.C.C PART B1.4 FOR CLASS 2 TO 9 BUILDINGS AS TO PREVENT GENERAL MOISTURE PENETRATION, DAMPNESS,
- 865MM MIN. ABOVE FINISHED SURFACE LEVEL OF STAIR NOSING OR
- WATERPROOFING OF WET AREAS, BEING BATHROOMS, SHOWERS, WEAKENING AND UNDERMINING OF ANY BUILDING AND ITS FOOTING
RAMP, AND
SHOWER ROOMS, LAUNDRIES, SANITARY COMPARTMENTS AND SYSTEM.
- VERTICAL WITH LESS THAN 125MM GAP BETWEEN, AND
THE LIKE SHALL BE PROVIDED IN ACCORDANCE WITH AS - THE APPROVAL BY THIS OFFICE OF A SUBSTITUTE MATERIAL, WORK
- ANY HORIZONTAL ELEMENT WITHIN THE BALUSTRADE BETWEEN 150MM
3740-2010: WATERPROOFING OF WET AREAS WITHIN RESIDENTIAL PRACTICE, VARIATION OR THE LIKE IS NOT AN AUTHORISATION FOR ITS USE
AND 760MM ABOVE THE FLOOR MUST NOT FACILITATE CLIMBING
BUILDINGS. OR A CONTRACT VARIATION. ANY SAID VARIATIONS MUST BE ACCEPTED
WHERE CHANGES IN LEVEL EXCEEDS 4000MM ABOVE THE SURFACE
BY ALL PARTIES TO THE AGREEMENT AND WHERE APPLICABLE THE
BENEATH LANDINGS, RAMPS AND/OR TREADS.
SUSTAINABILITY MEASURES FOR NEW CLASS 1 BUILDINGS. RELEVANT BUILDING SURVEYOR PRIOR TO IMPLEMENTING THE SAID
WIRE BALUSTRADE CONSTRUCTION TO COMPLY WITH N.C.C 2019
VARIATION.
THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ANY HOUSE VOLUME 2 PART 3.9.2.3 FOR CLASS 1 AND 10 BUILDINGS AND N.C.C
ENERGY RATING (HER) REPORT AND SHALL BE CONSTRUCTED IN 2016 VOLUME 1 PART D2.16 FOR OTHER CLASSES OF BUILDINGS.
ACCORDANCE WITH THE STAMPED PLANS ENDORSED BY THE ACCREDITED - HAND RAILS TO BE 865MM MINIMUM ABOVE STAIR NOSING AND
THERMAL PERFORMANCE ASSESSOR WITHOUT ALTERATION. LANDINGS. STORMWATER
100MM DIA. CLASS 6 UPVC STORMWATER LINE LAID TO A MINIMUM GRADE OF
SITE BUSHFIRE ATTACK ASSESSMENT. 1:100 AND CONNECTED TO THE LEGAL POINT OF STORMWATER DISCHARGE.
- WINDOW SIZES NOMINATED ARE NOMINAL ONLY. ACTUAL SIZE MAY
REFERENCE DOCUMENT AS 3959-2009 CONSTRUCTION OF BUILDINGS IN PROVIDE INSPECTION OPENINGS AT 9000MM C/C AND AT EACH CHANGE OF
VARY ACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHED ALL
BUSHFIRE PRONE AREAS. DIRECTION. THE COVER TO UNDERGROUND STORMWATER DRAINS SHALL BE NOT
AROUND.
LESS THEN;
- WHERE THE BUILDING (EXCLUDES CLASS 10) IS LOCATED IN A TERMITE
- 100MM UNDER SOIL
BUSHFIRE ATTACK LEVEL:- (BAL) PRONE AREA THE AREA TO UNDERSIDE OF BUILDING AND PERIMETER IS TO
- 50MM UNDER PAVED OR CONCRETE AREAS
BE TREATED AGAINST TERMITE ATTACK.
BAL-N/A - CONCRETE STUMPS: UP TO 1400MM LONG TO BE 100MM X 100MM (1 NO.
H.D. WIRE) 1401MM TO 1800MM LONG TO BE 100MM X 100MM (2 NO. H.D.
- 100MM UNDER UNREINFORCED CONCRETE OR PAVED DRIVEWAYS
- 75MM UNDER REINFORCED CONCRETE DRIVEWAYS
WIRES) 1801MM TO 3000MM LONG TO BE 125MM X 125MM (2 NO. H.D.
ALL HOMES TO COMPLY WITH AS 3959-2009 (BAL) WIRES) 100MM X 100MM STUMPS EXCEEDING 1200MM ABOVE GROUND PLIABLE MEMBRANES
LEVEL TO BE BRACED WHERE NO PERIMETER BASE BRICKWORK PROVIDED. AS PER CLAUSE 3.8.7.2 OF NCC 2019 A PLIABLE BUILDING MEMBRANE TO BE
WIND SPEED ASSESMENT: - FOR BUILDINGS IN MARINE OR OTHER EXPOSURE ENVIRONMENTS SHALL INSTALLED THAT COMPLIES WITH AS/NZS 4200.1 AND TO BE INSTALLED IN
MAXIMUM DESIGN GUST
SELECT WIND HAVE MASONRY UNITS, MORTAR AND ALL BUILT IN COMPONENTS AND THE ACCORDANCE WITH AS/NZS 4200.2 AND MUST BE A VAPOUR PERMEABLE
WIND SPEED FOR THIS SITE IS:
SPEED LIKE COMPLYING WITH THE DURABILITY REQUIREMENTS OF TABLE 5.1 OF MEMBRANE FOR CLIMATE ZONES 6/7/8." ALTERNATIVELY, SECTION 10 MAY BE
IMPORTANT NOTE: ADOPTED UNDER THE PROVISIONS OF NCC 2019 CLAUSE 3.8.7.2 - PLIABLE
THE WIND SPEED CALCULATION IS TAKEN FROM THE JOB SPECIFIC AS3700-2011 MASONRY STRUCTURES
SOIL REPORT (FRONT PAGE)
- ALL STORMWATER TO BE TAKEN TO THE LEGAL POINT OF DISCHARGE TO THE BUILDING MEMBRANE
STANDARD HOMES ARE DESIGNED TO SUIT A MINIMUM WIND GUST RELEVANT AUTHORITIES APPROVAL.
SPEED OF 33 m/s
- THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH ALL RELEVANT CONDENSATION MANAGEMENT
STRUCTURAL AND ALL OTHER CONSULTANTS DRAWINGS/ DETAILS AND WITH AS PER CLAUSE 3.8.7.3 OF NCC 2019 EXHAUST FROM A BATHROOM, SANITARY
ANY OTHER WRITTEN INSTRUCTIONS ISSUED IN THE COURSE OF THE COMPARTMENT, OR LAUNDRY MUST BE DISCHARGED DIRECTLY VIA A SHAFT OR

NOTE -
CONTRACT.
SITE PLAN MEASUREMENTS IN MILLIMETRES - ALL OTHER MEASUREMENTS IN
DUCT TO OUTDOOR AIR; OR TO A ROOF SPACE THAT IS VENTILATED IN
ACCORDANCE WITH 3.8.7.4
MADISON & CO DRAWING SET TO BE READ IN MILLIMETRES U.N.O.
- FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS.
CONJUNCTION WITH STRUCTURAL & CIVIL
ENGINEERING DRAWINGS BY FMG
ENGINEERING
PRELIMINARY ONLY
Rev

DRAWING TITLE: EXISTING/DEMO SITE PLAN Client: G. MIFSUD


P1
Rev Date Issue Rev Date Issue Rev Date Issue Project: PROPOSED PERGOLA @
P1 30.09.22 ISSUED FOR PRELIMINARY REVIEW 32 HUNTINGTOWER CRES Drawing No. Scale
1 of 4 --
LANGWARRIN Date Drawn
M a d i s o n & C o. © COPYRIGHT SEPT. 2022 JA
P. 0418 324 348 / E. madisonandcodesign@gmail.com / RBP: DP-AD 37979 This plan or design may not be copied, loaned of borrowed without the written consent of Madison & Co
EXISTING S/S HOUSE

EASEME
SITE ANALYSIS 10
2.1

NT 3.0M
9

LOT 41
PROPOSED AREA: 296.51m²

RIDGE RL

RIDGE RL
SITE AREA: 999.00m²
NON PERMEABLE 161m²
PERMEABILITY 55.00%
SITE COVERAGE 29.68%

10

10
7.8

7.7
GARDEN AREA 54.76%

9
SOIL CLASSIFICATION
CLASS "TBC"

RIDGE RL

HAB
DOOR

RIDGE RL
HAB

RIDGE RL
AS PER SOIL REPORT PROVIDED BY "TBC"

U.C.A
HAB
FILE No: TBC

HAB
DATED: TBC

FFL 1

EAVE RL
LEVELS

HAB
HAB

10
10

5.2
01
LEVELS SHOWN ARE TO AN ARBITRARY DATUM AND ARE TO

10HAB
5.6

10
3
.91

DOOR
6.6
BE USED AS A GUIDE ONLY. BUILDER TO CHECK AND VERIFY

HAB

5.6
8

HAB
GARAGE

2
ON SITE PRIOR TO ANY WORK BEING CARRIED OUT.

6
P.O.S
ALL LEVELS ON DRAWINGS ARE NOMINAL AND MAY ALTER
DUE TO SITE CONDITIONS UP TO 50mm EITHER WAY. 10

6M N/NATIVE

P.O.S
5.2
Approx.6.0

EAVE RL
GENERAL 3
-CONTRACTOR IS RESPONSIBLE FOR SETTING OUT AND

P.O.S
CHECKING ALL LEVELS AND MEASUREMENTS ON SITE PRIOR
TO COMMENCEMENT OF ANY WORK. EXISTING 1.90M PALING FENCE EXISTING RETAINING WALL
-ALL WORK IS SUBJECT TO INSPECTION AND APPROVAL OF

U.C.A
+0.45M EXT

10
RELEVANT BUILDING SURVEYOR.
101 251°13'
S/W PIT

5.2
101 5.5M N/NATIVES CHECK EASEMENT
-ALL WORK SHOWN TO BE CARRIED OUT IN GOOD
.4

3
.2 101 // // // // //
HUNTINGTOWER

WORKMAN LIKE MANNER IN ACCORDANCE WITH // // // // // // // // // // // // // // // // // // //


101.4
53.69M .2 101

EXISTING
3.5M N/NATIVE 8
10

10
10 1
10101 .09

POND
101
"NATIONAL CONSTRUCTION CODE -2015".

1010 10
10

10
EXISTING RETAINING WALL 5.5M N/NATIVES 101.2

1.5M N/NATIVES

//
0.1
1
101

10 10

1.3 01
1.4 .38
10.41 EXISTING 101

1.21. 1.
1.1

10

1.2
11000 11000
.41
-WORK SHOWN TO BE IN ACCORDANCE WITH // // //

6M NATIVE
3020
1.2 1.2

3
RETAINING WALL
101.2101

4 .10
1
0
19015

1.2.9 1. .95
6M N/NATIVE

5.35

628 24
1

1
SPECIFICATIONS/COMPUTATIONS SUPPLIED. 10

3 4
10

1101010
101

46 22
RETAINING WALL

10
10
1.0

10

10 .26
U.C.A

0
101

10.2.9
1
.98
10

1.85M P
0.9

1.0
6

.25
EXCAVATION

10
1.0

69

//
9

4
10
0.9

//
1
-EXCAVATE FOOTINGS AND DRAINS AS SHOWN. KEEP

10
10
0.9

PRIVACY SCREEN
6

1.0
0.9
EXCAVATIONS DRY AND BACKFILL WITH APPROVED 10

6
1.0

ALING F
MATERIALS FREE OF ANY BUILDING DEBRIS.
1 101

//
101
STORMWATER DRAIN 100

10
LOT 40

.13
10

RIDGE RL
KEEP AREA

101

//
101
.8

1.0
0.9

RIDGE
10
CONSTRUCT & DISCHARGE 100 DIA. P.V.C STORM WATER

10

10
10

CLEAR OF

2
1.0
9

ENCE
5.5
1.1
DRAIN TO LEGAL POINT OF DISCHARGE AS DIRECTED BY THE
No. 32
1.0

0
10
PIPEWORK

2
2
RELEVANT AUTHORITY. MIN FALL 1:100 PROVIDE INSPECTION
5

FFL

//
1.0
EXISTING S/S HOUSE PERGOLA

RL
OPENINGS AT 9000 MAX CTRS OR AT EVERY CHANGE OF
153°45'40"

FOR

RIDGE RL

0
DIRECTION. DP DENOTES 100x50 DOWNPIPES AT 12000 MAX
100

330°48'4
10 10 (999sqm) FFL: RL 101.90
18.60M

FUTURE

10
CTRS. PROVIDE 100 DIAM SEWERGRADE S.W DRAIN UNDER
.6 0.9 1.1

GARAGE
11000
10

5.5
10.966
SLAB AND DRIVEWAY 7 9 POOL.
0.9

EAVE RL

//
0.9

0.9

18.75M
EXISTING FFL: RL 101.90

U.C.A
WATERPROOFING 7 MAX.

7
BUILDER TO PROVIDE WATERPROOFING DEPTH OF
TAP

100

10

10

0"
MEMBRANE FOR INTERFACE BETWEEN POOL TO
100.8

//
.4

5.0

1.0
GARDEN BEDS AND CONCRETE 20745

8
BE 1.8M

6
10
SLABS/BRICKWORK/RENDERED WALLS
CRESCENT

3.310
G/W

10
2 0.9
100.8

1.0
TERMITE PROTECTION 10

10

//
10

100 0.7

4
10

0.9
10

7
PROVIDE TERMITE TREATMENT IN
0.5

.2 2 0.9

GAS 0.9
0.9

100 10
ACCORDANCE WITH AS 3660.
1

10 10 8 6
1.5M N/NATIVES100.6

.8
SITING SUBJECT TO APPROVAL BY RELEVANT 100.6 0.9

10 100.
0.7

10

10

//
10 10 10

// 10

5.5 82
LOCAL AUTHORITY 7
10 100 0 10

1.0
0.6 10 0.8 0.8

5820
0.9

310
10
0.7

10
0.5

1010.6
1

100

1
100 10 0 .
10

0.5 .87 81 7 5

10
10
7

1.01

0.6
0
8

0.6
6

10
.59
0.6

10

0.6
10 6

0.5
00

10
100.6

.6
DEMOLITION NOTE

000.

2
0.5

4
0.5

0.5
2

.5

10
0.7
10

2 10
9
100

0.3
7

10

0.4
//

//
0
.2
3.5M N/NATIVE

DASHED LINES INDICATE AREAS TO DEMOLISH


0

8
9
.43 100.4

10
0.54

0
100 100

EXISTING 1.83M PALING FENCE

.64
// // // // // // // // //
10 10 // // // // // // // // //
10 // 10

4M N/NATIVE
GUTTER
TOP

0.2 0 APPROX 0.6M RETAINING WALL 0.5 0.5


10
10
10 .00

54.66M

10
10 OF

.33

10

10
ELECTRICITY PIT

7 4 2M N/NATIVES
0.2 NH
0.2
0.

0.4
1.9

0.3

0.3
DOOR
07

1
1

2
4

NH

5
71°13'

HAB
HAB

NH
NH
DOOR
NH

NH
GARAGE
TBM ELECTRICITY PIT
RL 100.00

HAB
RIDGE

IN AREA
10

EXISTING S/S HOUSE

POOL
RIDGE RL
3.6
5

P.O.S
RL

LOT 39
Approx.4.9

10
4.5
7
NO
RT
H PRELIMINARY ONLY
Rev

DRAWING TITLE: SITE PLAN Client: G. MIFSUD


P1
Rev Date Issue Rev Date Issue Rev Date Issue Project: PROPOSED PERGOLA @
P1 30.09.22 ISSUED FOR PRELIMINARY REVIEW 32 HUNTINGTOWER CRES Drawing No. Scale
2 of 4 1:200
LANGWARRIN Date Drawn
M a d i s o n & C o. © COPYRIGHT SEPT. 2022 JA
P. 0418 324 348 / E. madisonandcodesign@gmail.com / RBP: DP-AD 37979 This plan or design may not be copied, loaned of borrowed without the written consent of Madison & Co
IMPORTANT NOTE: GENERAL NOTES
REFER TO ENGINEERS DESIGN FOR ARTICULATION - WRITTEN DIMENSIONS TAKE PREFERENCE OVER SCALE
JOINT LAYOUT - UNLESS OTHERWISE INDICATED ALL WALL DIMENSIONS ARE AS FOLLOWS:
* EXTERNAL RENDERED BRICK 225mm = 110 BRICK, 25 CAVITY, 90 STUD
* EXTERNAL FEATURE BRICK 225mm = 52 BRICK, 83 CAVITY, 90 STUD
NOTE: * INTERNAL 90mm STUD, * INDICATES 45mm STUD
- PROVIDE REMOVABLE HINGES TO ALL HINGED WC & POWDER
PENETRATIONS THROUGH THE SISALATION PAPER ROOM DOORS WHEN DISTANCE FROM THE DOOR OPENING TO
ARE TO BE TAPED AROUND CAREFULLY TO ENSURE THE PAN IS LESS THAN 1200mm FOR INWARD SWINGING DOORS.
- PROVIDE WEATHER STRIPS TO FRONT ENTRY DOOR
ANY GAPS ARE SEALED. SD
- SMOKE DETECTOR (HARDWIRED WITH BATTERY BACKUP)

-ALL DIMENSIONS ARE TO STUD FRAME.PLASTER AND


SKIRTING BOARDS NOT CONSIDERED.

5000

4830 170
DP EX
CL POST CL POST
2100HX1800W SL 1000HX900W SL
EXISTING EXISTING DP
2100HX1800W SL 2100HX1800W SL 1000HX600W SL1000HX600W SL

170
EXISTING EXISTING EXISTING EXISTING DP ST
PO
DP
EXISTING 1000HX1500W SL BEAM TO ENG'S
EXISTING
EXISTING

900W A
2100HX

BROOM
DESIGN

EX
BULKHEAD BULKHEAD EXISTING
EX

BEAM TO ENG'S
.
ENS WC

ROBE
EX

DESIGN
TILES L'DRY TILES

EQUAL
CL POST
GARAGE
TILES BATH
BED1 DINING BED2 EX
. TILES

LINEN
CARPET TILES CARPET

EX

EX
EXISTING

900W A
2100HX

ST
WIR PO
EX
CARPET
EXISTING
BULKHEAD EX EX

BEAM TO ENG'S
EX
EX

EX

DESIGN

EQUAL
CL POST
EX
EXISTING
UP
GARAGE DOOR ENTRY PERGOLA

2100HX1800W SL
TILES TREATED PINE
EXISTING DECKING ST

EXISTING

9600
BULKHEAD BOARDS ON PO
DP BED3 BATTENS OVER
UP CARPET
EX EXISTING
CONCRETE PAD

BEAM TO ENG'S

EQUAL
DESIGN

CL POST
CONCRETE
PORCH

KITCHEN FAMILY
TILES ROBE
TILES ROBE X
2100HX2700W SL

ST
PO
LIVING
EXISTING

EX
CARPET

BEAM TO ENG'S

EQUAL
2100HX1800W SL

CL POST
DESIGN
EXISTING
BED4
CARPET
1000HX1800W SL 2100HX2700W SD BEAM TO ENG'S
DP
EXISTING EXISTING DESIGN
02 DP
ST

170
01
PO

950
250
UP
2100HX2700W SL
DP TREATED PINE 135 X 135 DAR
EXISTING
VERANDAH STEP TREATED PINE
POSTS (TYP)

4830 170
CL POST CL POST
5000
DP

C
D

AREA SCHEDULE
m² sq
EXISTING 248.51 26.75
PROPOSED 48 5.17
GRAND TOTAL 296.51 31.92
PRELIMINARY ONLY
Rev

DRAWING TITLE: GROUND FLOOR PLAN Client: G. MIFSUD


P1
Rev Date Issue Rev Date Issue Rev Date Issue Project: PROPOSED PERGOLA @
P1 30.09.22 ISSUED FOR PRELIMINARY REVIEW 32 HUNTINGTOWER CRES Drawing No. Scale
3 of 4 1:100
LANGWARRIN Date Drawn
M a d i s o n & C o. © COPYRIGHT SEPT. 2022 JA
P. 0418 324 348 / E. madisonandcodesign@gmail.com / RBP: DP-AD 37979 This plan or design may not be copied, loaned of borrowed without the written consent of Madison & Co
ROOF EXTENDA BRACKET INSTALLED ON EXISTING TOP
PLATE. BRACKET TO BE INSTALLED AS PER
MANUFACTURERS REQUIREMENTS. PROVIDE FLASHING COLORBOND
AS REQUIRED CAPPING

COMBINATION COLORBOND ROOF & TREATED PINE TIMBER


LASERLITE (OVER HABITABLE WINDOWS) FRAMING. REFER TO
ENGINEERING
@ 22.5° PITCH FOR DETAILS

ROOF EXTENDA BRACKET


INSTALLED ON EXISTING TOP COLORBOND &
PLATE. BRACKET TO BE POLYCARBONATE
GUTTER TO
INSTALLED AS PER ROOFING @ 22.5°
MATCH
MANUFACTURERS PITCH ON 70 X 35
EXISTING WITH
REQUIREMENTS. PRIVDE BATTENS
SPREADER
FLASHING AS REQUIRED
GUTTER TO
UNDERSIDE OF BEAM

4400
MATCH
EXISTING

EXSITING FL-CL
2615

2400
EX.
EX. EX. 135 X 135 DAR
TREATED PINE
POSTS (TYP)

EX.

EXISTING BRICK
VENEER WALL
EXISTING DWELLING

2400 EXISTING FL-CL


F7 TREATED PINE (240mm)
PLINTH BOARDS
A ELEVATION BED04
PERGOLA

SCALE - 1:100

COMBINATION COLORBOND ROOF &


TREATED PINE
LASERLITE (OVER HABITABLE WINDOWS) DECKING BOARDS
@ 22.5° PITCH GUTTER TO MATCH
ON TIMBER BATTENS
OVER EXISTING TREATED PINE
EXISTING CONCRETE PAD PLINTH BOARD

LA LT LA LT LA LT LA LT
UNDERSIDE OF BEAM

EX. EXISTING CONCRETE


PAD
2615

2400
EX. EX. Y-Y SECTION
- SCALE - 1:50

EXISTING
F7 TREATED PINE DWELLING
F7 TREATED PINE
PLINTH BOARDS BEYOND
STEP

B ELEVATION
SCALE - 1:100
ROOF EXTENDA BRACKET INSTALLED ON
EXISTING TOP
PLATE. BRACKET TO BE INSTALLED AS PER
MANUFACTURERS REQUIREMENTS. PROVIDE COMBINATION COLORBOND ROOF &
FLASHING AS REQUIRED LASERLITE (OVER HABITABLE WINDOWS)
@ 22.5° PITCH
UNDERSIDE OF BEAM
EXISTING FL-CL

2615
2400

2.
1.

F7 TREATED PINE F7 TREATED PINE


EXISTING DWELLING PLINTH BOARD STEP

C ELEVATION PRELIMINARY ONLY


SCALE - 1:100
Rev

DRAWING TITLE: ELEAVTIONS / SECTIONS Client: G. MIFSUD


P1
Rev Date Issue Rev Date Issue Rev Date Issue Project: PROPOSED PERGOLA @
P1 30.09.22 ISSUED FOR PRELIMINARY REVIEW 32 HUNTINGTOWER CRES Drawing No. Scale
4 of 4 1:100
LANGWARRIN Date Drawn
M a d i s o n & C o. © COPYRIGHT SEPT. 2022 JA
P. 0418 324 348 / E. madisonandcodesign@gmail.com / RBP: DP-AD 37979 This plan or design may not be copied, loaned of borrowed without the written consent of Madison & Co

You might also like