You are on page 1of 1

GENERAL NOTES

1. ALL DIMENSIONS ARE IN MILLIMETERS. ALL LEVELS ARE GIVEN


IN METERS UNLESS OTHERWISE NOTED.
2. ALL CONSTRUCTION & INSTALLATIONS SHALL COMPLY WITH AMIES
ENGINEERING STANDARDS AND SPECIFICATIONS.
3. ALL WALLS SHALL PROVIDE BALLISTIC PROTECTION TO NIJ 0108.01,
LEVEL III.
4. DOORS SHALL COMPLY WITH AMIES-O-209.

1 2 3 4 5 6 7
26610

ALUMINUM COPING ALL AROUND


TOP BUILDING OVER PARAPET LEGENDS AND ABBREVIATIONS
EL. +105.700

50MM THK GRAVEL ON 12MM


AGGREGATES NON WOVEN TOP TOP OF PARAPET ESD EMERGENCY SCUPPER DRAIN
TORS ESD MEMBRANE FULLY ADHERED EPDM
EL. +104.500
SINGLE PLY ROOF MEMBRANE TORS TOP OF ROOF SLAB X GRID LABEL
RIGID INSULATION 75MM (R15) 50MM
THK. MIN. SCREED TO FALL ON TOW TOP OF WALKWAY
CEILING LEVEL
CONCRETE ROOF SLAB FFL FINISHED FLOOR LEVEL
EL. +103.000
BATTERY ROOM ACID RESISTANT PAINT FINISH ON
EXPOSED CEILING FGL FINISHED GRADE LEVEL
010

3405
CORRIDOR SECURITY CONTROL SECURITY SB PRE-CAST CONCRETE SPLASH BLOCK
FEMALE EQUIPMENT 200x200MM ACID RESISTANT TILES
005 ROOM
TOILET ROOM D4 D1 SD PRE-CAST CONCRETE SCUPPER DRAIN
012
FFL 002 011 600x600MM HEAVY DUTY RAISED
EL. +100.300
FLOOR PANEL DX DOOR TAG
TOW
EL. +100.150 THK THICKNESS

900

900
FGL
EL. +100.000

E SECTION
001 SCALE 1:75M

F E D C B A
16760

SA-AMI-521-MOSU-000XXX DOORS SCHEDULE - SECURITY CONTROL CENTER

SA-AMI-521-MOSU-000XXX FINISHING SCHEDULE - SECURITY CONTROL CENTER


ALUMINUM COPING ALL AROUND
TOP BUILDING OVER PARAPET
EL. +105.700 SA-AMI-521-MOSU-000XXX ROOF PLAN - SECURITY CONTROL CENTER
50MM THK GRAVEL ON 12MM
AGGREGATES NON WOVEN SA-AMI-521-MOSU-000XXX BUILDING ELEVATIONS - SECURITY CONTROL CENTER
TORS SD SD MEMBRANE FULLY ADHERED EPDM
EL. +104.500
SINGLE PLY ROOF MEMBRANE SA-AMI-521-MOSU-000XXX FLOOR PLAN - SECURITY CONTROL CENTER
RIGID INSULATION 75MM (R15) 50MM
THK. MIN. SCREED TO FALL ON
CONCRETE ROOF SLAB Drawing No DESCRIPTION
CEILING LEVEL
EL. +103.000
100MM DIA PVC DOWN PIPE
REFERENCE DRAWINGS
600x600MM ACOUSTIC CEILING TILE
SECURITY CONTROL MALE 2400
ROOM D7 BREAKOUT / AREA
CORRIDOR
FFL 012 005 006
EL. +100.300
600x600MM HEAVY DUTY RAISED
TOW
EL. +100.150
FLOOR PANEL
SB 0 IFR 01-Dec-2023 ISSUED FOR 60% REVIEW T.Alam A.Rahim M. Ahmad
900

FGL
EL. +100.000 Issued Reviewed Approved
Rev. Step Rev. Date Revision Description By By By
38MM DIA STAINLESS
STEEL HANDRAIL

F SECTION
001 SCALE 1:75M
AMIRAL
PROJECT

This document is the property of AMIRAL and shall not be disclosed to third parties or reproduced without permission of the owner.

This document has been generated by an Electronic Document Management System. When printed it is considered as a for information only
copy. The controlled copy is the screen version and it is the holder's responsibility that he/she holds the latest valid version.

BUILDING SECTIONS
SECURITY CONTROL CENTER (SCC)
Doc Type: DRW Discipline: CIV Phase: DE Class: 2 System / Subsystem : Equipment :
Contractor Contractor
Document Document SA-AMI-521-MOSU-000XXX
Number: ID:

Vendor
Document Rev: 0 Scale: 1:75 Format: Folio: 1 OF 1
Number: