KH NOTES :
1-THE ELECTRICAL INSTALLATIONS SHALL BE CARRIED OUT IN COMPLIANCE
WITH THE CURRENT EDITION OF "THE REGULATIONS FOR INSTALLATION
OF ELECTRICAL WIRING , ELECTRICAL EQUIPMENT AND AIR CONDITIONING
EQUIPMENT".
2-MV PANEL DETAILS / MANUFACTURER'S DRAWINGS SHALL BE SUBMITTED TO
QATAR GENERAL ELECTRICITY AND WATER CORPORATION (KAHRAMAA) FOR
PRIOR APPROVAL BEFORE IT IS MANUFACTURED
3-TOTAL VOLTAGE DROP SHALL NOT EXCEED 2.5%
0
5.0
STAIR ROOF S 2
RO
ROOF DECK Energy Conservation - Special Notes:
General:
AD
40
C/C 10.30M.SLOPE 1:60
Design and Construction of building shall comply with the provisions of the following
.0
150 MM∅ ESVC PIPE
KAHRAMAA regulations.
0
ACCOMMODATION ROOF 1) Regulation for the installation of electrical wiring, electrical equipment and air
conditioning equipment December 2010 edition. THE SITE
Electrical Installation
All possible energy saving measures adopted in lighting sector.
BA-LP-D-085
Energy saving lamps is proposed wherever applicable.
NE
40
Necessary provisions are included in design/construction to reduce the cooling load and
corresponding electrical demands by property selecting building materials, insulation to
C/ walls and roof and energy efficient windows as applicable.
.0
C
IG
8. All air conditioning equipments are sized and selected as per cooling load calculations.
1
0
15 5M
0 .S
HB
Energy efficiency and conservation measures area considered while selecting HVAC
MM LO
∅ PE systems and equipments.
ES 1:
00 OR
VC 60
OR
**Water Conservation - Special Notes:
PI
PE
.
25 HB
All the plumbing fixtures shall comply with applicable water conservation measures as
stipulated under Section 7.0 of Regulations of Internal Water Installations & Connection
NEIGHBOR
Works May 2009.
E IG
MANHOLE SCHEDULE N
FIRE TRUCK ACCESS
MH-4
BOUNDARY WALL
300
CABINET DOOR
32Ømm GO TO MEZ/FLOOR
MH-3
CONSULTANT REG. NO.:
C/C 2.25M.SLOPE 1:60
1 SERVICE CABINET
BELOW G.L FOR TELE CABLE PROVISION FOR RAIN WATER COVER 3 80mm UPVC SLEEVE LONG RADIUS BEND
CONSUMER NUMBER
(WITH DRAW ROPE) MH-2 HINGES
LOUVERED VENTILATION
C/C 4.00M.SLOPE 1:60
WITH STAINLESS STEEL note : Service Cabinet & 800 mm UPVC Sleeve to be installed by the Customer
150 MM∅ ESVC PIPE
VERMIN SCREEN
COUPLING TO FIX
50mm∅ PVC DUCT 600mm ALUM. CABINET DOOR COPPER PIPE
KAHRAMAA LOGO
BELOW G.L FOR TELE CABLE UNION NUT
TECHNICAL MANAGER
2
(WITH DRAW ROPE) Service Cabinet for Water
1
6mm GEORGIAN WIRED
NEOPRENE GASKET
GLASS TO METER READING
FACILITY (INSIDE PROVIDED) Meters (Sizes 22mm to 42mm) GRADE: A
TYPE-B
(100 x 100)
ELECTRONIC WATER METER
REGISTRATION NO.:
PARKING AREA FOR KAHRAMAA LOCK 1
install water pipes from
Ground water tank to PROJECT:
service cabinet
EXIT
2000GL
ENTRANCE
the cabinet LOCATION: INDUSTRIAL AREA
COPPER SERVICE PIPE 15-42mm
42mmØ HOLE WITH RUBBER BUSH
TO ALLOW SMALLER SIZE PIPES
15, 22 & 28mm (BOTH SIDES)
CLIENT:
WATER
METER CABINET FRONT VIEW
FROM DISTRIBUTION MAIN
SECTION A-A
PVC Duct concealed in the boundary wall MARINA CONSULTING AND
SCALE 1:5 SCALE 1:5
22Ømm PVC
GO TO SEWER
ENVIRONMENTAL STUDIES
DETAIL OF ELECTRONIC WATER METER & CABINET
Pipe should be extended at least
DESIGN & CONSULTANT:
MILLET INTERNATIONAL
300mm below finished ground level
WATER DEPT.
FROM QGEWC
ARCHITECTURE ENGINEERING
EXIT MAIN ROAD ENTRANCE
NOTES FOR MAINLAYING, SERVICE PIPE EXTENSION,
MANHOLE 28Ø TANKER INLET PIPE
35Ø VENT PIPE WITH INSECT GUARD
PROVISION OF STORAGE FACILITIES AND PLUMBING
DOHA QATAR PO. BOX 22494 TEL. + 974 44864004 FAX. + 974 44860550
E-mail :qr@milletintl.com
SITE PLAN Ooredoo GENERAL NOTES
1. All Civil works to be executed by customer/contractor under
22Ø TANK ADAPTOR
EXISTING PROPOSED 4. Block wiring to be executed by certified Ooredoo contractor. CONCRETE FOUNDATION
GROUND LEVEL ±0000
3. GROUND/ROOF TANKS SHALL BE OF SUITABLE VOLUMES TO PROVIDE DR. SALMAN AL GHATAM GAMAL ABDUL HAKEEM
UNDERGROUND DUCT 5. Cable works to be laid by Ooredoo free charge up to main telecom
room and on rechargeable basis for sub telecom rooms.
ADEQUATE SUPPLY AGANIST LEVEL OF CONSUMPTION.
RECESS IN CONCRETE FOUNDATION REGISTRATION NO.:
RLU 6. Cable trays width should be between 30cm to 60cm. REGISTRATION NO.: 2851 REGISTRATION NO.: 2900
4. ALL PLUMBING WORKS SHALL BE HANDELED BY
CABINET
7. For Internal connections (block wiring). Refer to (Ooredoo web site). TYPICAL POTABLE GROUND WATER KAHRA MAA APPROVED PLUMPING OR PLUMPING CONTRACTORS SIGNATURE: SIGNATURE: SIGNATURE:
- Internal cabling guidelines.
STORAGE TANK CONNECTIONS DETAIL 5. THE DISTRIBUTION NETWORK FOR LARGE COMPLEX COMPRISING
DP - Telecom Equipment room guidelines.
OF SEVERAL VILLAS OR DWELLING UNITS, SHALL BE LAID IN
8. All telecom jobs to be executed as per Ooredoo standards & regulations.
ACCORDANCE TO KAHRA MAA SPECIFICATION FOR MAINLAYING MATERIALS AND
MANHOLE 9. Telecom Room size ----m x----m. ** Water Conservation-Special Notes
MAINLAYING CONTRACTS - JANUARY 1993 OR ANY UPDATE
10. Ooredoo approval is provided for external telecom. network only.
6. ALL WATER METERS SHALL BE SECURELY ACCOMMODATED
SCALE : AS SHOWN DATE:
JOINT BOX All the plumbling fixtures shall comply with
11. All internal infrastures inside the building are under consultants /
contractors reponsibilties.
INSIDE METER CABINETS.
REV. NO.:
03 - JUNE - 2017
POLE
12. Consultant to contact GSM department for their requirements. applicable water conservation measures as
CABLE TRAY 13. Contractor should contact Ooredoo Plant Protecting Officer PPO. stipulated under section 7.0 of Regulations SHEET NO.: PROJECT NO.:
On Tel 44400500 / 44600700 prior to excuvation. SSP-01
TUNNEL
of Internal Water Installations & Connnection
ORIGINAL SIZE
QP/16/165
Works May 2009. A1
GENERAL NOTES :
GENERAL NOTES :
PROVIDING WINDOWS IN
PLANS AND ELEVATIONS.
NEIGHBOR
1 2 3 4 1 2 3 4
UP
5
W
12
PANTRY
8.00 sq.m
1
2
3
BATH
W
08
BEDROOM BEDROOM
12.16 sq.m 12.16 sq.m
BATH
1 2 3 4 1 2 3 4
NEIGHBOR
TYPICAL DETAIL OF BATHROOM W/SUPPLY LAYOUT
FIRE TRUCK ACCESS
OPEN BELOW
STORE 01 LEGEND
WITH PROPER
INSULATION 1 VENT PIPE FROM W/HEATER (15mmØ)
STORE FOR MARINE SUPPLIES METAL ROOFING 4 C.W. SUPPLY TO BIDET (22mmØ)
WITH INSULATION
ON STORE BELOW 5
FIRE TRUCK ACCESS
UP
DN
SHOWROOM FEMALE
PANTRY WC
OFFICES TECHNICAL MANAGER
1 2
1 2
GRADE: A
STORE 03
3
3
WITH PROPER
REGISTRATION NO.:
4
4
INSULATION MALE PANTRY PROJECT:
WC
MILLET INTERNATIONAL
WATER
TANK
2000GL
SCALE: 1:100
EXIT ENTRANCE
ARCHITECTURE ENGINEERING
WATER
METER CABINET DOHA QATAR PO. BOX 22494 TEL. + 974 44864004 FAX. + 974 44860550
22Ømm PVC ROOF W/TANK 22 vent pipe from W.H. E-mail :qr@milletintl.com
ROOF
TITLE:
WATER DEPT. GROUND FLOOR & MEZZANINE
MANHOLE 28Ø TANKER INLET PIPE
FROM QGEWC 35Ø VENT PIPE WITH INSECT GUARD
FLOOR WATER SUPPLY LAYOUT
22 C.W.S to BIDET
W.H. Wall mounted
EXIT 22Ø TANK ADAPTOR 24 at F.F. and 22 at
MAIN ROAD
35Ø TANK OVERFLOW PIPE 22 C.WS. to W.H 22 H.W.S. from W.H DR. SALMAN AL GHATAM GAMAL ABDUL HAKEEM
GROUND DRINKING WATER STORAGE TANK
W.BASIN
TANK ADAPTOR
CAPACITY : 2000 U.S. GALLONS
BIDET
B.TUB
W.C.
WATER TANK SIZE :2080mm. DIA. x 2270mm. HEIGHT 35Ø DRAIN VALVE REGISTRATION NO.: 2851 REGISTRATION NO.: 2900 REGISTRATION NO.:
35Ø COMBINED TANK DRAIN & OVERFLOW
35Ø WATER TANK OUTLET TO PUMPS SUCTION PIPE WITH INSECT GUARD SIGNATURE: SIGNATURE: SIGNATURE:
1 2 3 4 1 2 3 4 1 2 3 4
UP HALL UP HALL
PANTRY PANTRY
DN 8.00 sq.m DN 8.00 sq.m DN
ROOF DECK
BATH BATH
1 2 3 4 1 2 3 4 1 2 3 4
OPEN BELOW
TECHNICAL MANAGER
GRADE: A
1 2
1 2
1 2
REGISTRATION NO.:
3
3
PROJECT:
4
4
4
STORE FOR MARINE SUPPLIES
MILLET INTERNATIONAL
FIRST FLOOR PLAN SECOND FLOOR PLAN ROOF FLOOR PLAN ARCHITECTURE ENGINEERING
SCALE: 1:100 SCALE: 1:100 SCALE: 1:100
DOHA QATAR PO. BOX 22494 TEL. + 974 44864004 FAX. + 974 44860550
E-mail :qr@milletintl.com
TITLE:
ROOF W/TANK 22 vent pipe from W.H.
FIRST FLOOR & SECOND
ROOF
FLOOR WATER SUPPLY LAYOUT
1
2
MANHOLE 28Ø TANKER INLET PIPE CHECKED BY:
35Ø VENT PIPE WITH INSECT GUARD 3
STRUCTURAL ENG.: ARCHITECT ENG.:
22 C.W.S to BIDET LEGEND DR. SALMAN AL GHATAM GAMAL ABDUL HAKEEM
W.H. Wall mounted
22Ø TANK ADAPTOR 24 at F.F. and 22 at
24 rising main to ROOF W/TANK
B.TUB
W.C.
WATER TANK SIZE :2080mm. DIA. x 2270mm. HEIGHT 35Ø DRAIN VALVE
3 C.W. SUPPLY TO FIXTURE(22mmØ)
35Ø COMBINED TANK DRAIN & OVERFLOW
35Ø WATER TANK OUTLET TO PUMPS SUCTION PIPE WITH INSECT GUARD
4 C.W. SUPPLY TO BIDET (22mmØ)
350
REV. NO.:
03 - JUNE - 2017
RECESS IN CONCRETE FOUNDATION