SYMBOLS LEGEND CODE ANALYSIS GENERAL NOTES ABBREVIATIONS

1. ALL WORK SHALL COMPLY WITH CODES, LAWS, ORDINANCES, RULES, AND REGULATIONS OF PUBLIC
SECTION HATCHES & SYMBOLS CATEGORY CODE INFORMATION APPICABLE CODE SECTION AUTHORITIES GOVERNING THE WORK.
A K
CODES IN EFFECT 2. THE GENERAL CONTRACTOR SHALL OBTAIN & PAY FOR PERMITS & INSPECTIONS REQUIRED BY PUBLIC
AC AIR CONDITION(ING) KIT KITCHEN
SAND OR GROUT BUILDING 2015 INTERNATIONAL BUILDING CODE W/MCKINNEY AMENDMENTS AUTHORITIES GOVERNINGTHE WORK.
ACCESS ACCESSORY
MECHANICAL 2015 INTERNATIONAL MECHANICAL CODE W/MCKINNEY AMENDMENTS ACOUS ACOUSTICAL(AL
ELECTRICAL 2017 NATIONAL ELECTRIC CODE W/MCKINNEY AMENDMENTS 3. THE GENERAL CONTRACTOR SHALL REVIEW DOCUMENTS, VERIFY FIELD CONDITIONS & DIMENSIONS, &
EARTH OR NATURAL GROUND AFF ABOVE FINISHED FLOOR
PLUMBING 2015 INTERNATION PLUMBING CODE CONFIRM THAT WORK IS BUILDABLE AS SHOWN. REPORT ANY CONFLICTS OR OMISSIONS TO THE ARCHITECT
ACCESSIBILITY 2015 ADA ACCESSIBILITY GUIDELINES (ADAAG) & 2012 TEXAS ACCESSIBILITY STANDARDS FOR CLARIFICATION PRIOR TO PERFORMING ANY WORK IN QUESTION.
AL
ALT
ALUMINUM
ALTERNATE
L
POROUS FILL (GRAVEL) FIRE SAFETY 2015 INTERNATIONAL FIRE CODE
ANNUNC ANNUNCIATOR
2010 NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS 4. SUBMIT REQUESTS FOR SUBSTITUTIONS, REVISIONS, OR CHANGES TO ARCHITECT FOR REVIEW PRIOR TO LAV LAVATORY
ANOD ANODIZED
ENERGY CODE 2015 INTERNATIONAL ENERGY CONSERVATION CODE PURCHASE, FABRICATION OR INSTALLATION. LB POUND
APPL APPLIANCE
STONE ARCH ARCHITECT(URAL)
£ BRITISH POUND (CURRENCY)
BUILDING USE CLASSIFICATION 5. CENTER ELECTRICAL RECEPTACLES & OUTLETS NOT LESS THAN 15" ABOVE THE FLOOR OR WORKING LT LIGHT
PRINCIPAL CLASSIFICATION R-1 (RESIDENTIAL HOTEL) IBC Section 310.3
AUTO AUTOMATIC
PLATFORM. LVLG LEVELING
CONCRETE OTHER CLASSIFICATION(S) B (BUSINESS) + A-2 (ASSEMBLY-RESTAURANT) + A-3 (ASSEMBLY-MEETING) IBC Section 304.1, 303.3,303.4 AVG AVERAGE
LVR LOUVER
SPRINKLERED YES (ALL) IBC 903, 903.2.9.1 (Group S-1) & AND
6. OWNER WILL PROVIDE WORK NOTED "BY OTHERS" OR "NIC" (NOT IN CONTRACT) UNDER A SEPARATE
INCIDENTAL USE AREAS N/A IBC 509
BRICK (PLAN & SECTION) CONTRACT. INCLUDE SCHEDULE REQUIREMENTS IN CONSTRUCTION PROGRESS SCHEDULE AND
OCCUPANCY SEPARATION NONSEPERATED OCCUPANCIES IBC Table 508.4 COORDINATE TO ASSURE ORDERLY SEQUENCE OF INSTALLATION. B M
R/A- 1HR (SPRINKLER IBC Table 508.4
CONCRETE MASONRY UNIT (PLAN & B/R-1 HR (SPRINKLER IBC Table 508.4 7. COORDINATE TELECOMMUNICATION, DATA, & SECURITY SYSTEM INSTALLATIONS. BLDG BUILDING MAX MAXIMUM
SECTION) B/A 1 HR (SPRINKER IBC Table 508.4 BOLLD BOLLARD MFD MANUFACTURED
8. PROVIDE EXITS, EXIT LIGHTING, FIRE PROTECTIVE DEVICES, & ALARMS IN CONFORMANCE WITH CODES & BD BOARD MFR MANUFACTURER
BUILDING CONSTRUCTION TYPE ORDINANCES. BLKG BLOCKING MECH MECHANICAL
STEEL CLASSIFICATION IB IBC Section 602.2, Table 601 BRDLM BROADLOOM MTL METAL
MAXIMUM AREA (PER FLOOR) UNLIMITED AREA BUILDING IBC Section 506.2 9. PROTECT AREA OF WORK & ADJACENT PROPERTIES FROM DAMAGE. BU BUILT UP MEM MEMBRANE
MAXIMUM BUILDING HEIGHT (FT) 180' IBC Table 504.3 MEZZ MEZZANINE
NON-FERROUS ALUMINUM MAXIMUM # OF FLOORS 12 STORY IBC Table 504.4 MIN MINIMUM
10. MAINTAIN WORK AREAS SO THAT THEY ARE SECURE & LOCKABLE DURING CONSTRUCTION.
C MISC MISCELLANEOUS 50% DESIGN
PLYWOOD FIRE PROTECTION SYSTEM 11. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS GOVERN. IN CASE OR CONFLICT, CONSULT THE MLWK MILLWORK
SPRINKLER SYSTEM
STANDPIPE
YES, 2010 NFPA-13 ESFR
CLASS I
2010 NFPA-13
IBC Section 905.3.1 Exception 1
ARCHITECT.
CAB
CPT
CABINET
CARPET
MOIST MOISTURE DEVELOPMENT /
MOT MOTOR(IZED)
WOOD (FINISH) STANDPIPE HOSE CONNECTIONS REFERENCE CODE IBC Section 905.4
12. PARTITIONS ARE DIMENSIONED FROM FACE OF STUD TO FACE OF STUD, UNLESS NOTED OTHERWISE.
CEM
CER
CEMENT(ITIOUS)
CERAMIC
MTD MOUNTED GMP
PORTABLE FIRE-EXTINGUISHERS 4A RATED, 1A RATED REQUIRED, REFERENCE INTERNATIONAL FIRE CODE FOR LOCATIONS IBC Section 906.1
MAINTAIN DIMENSIONS MARKED AS "CLEAR", "HOLD", OR "FINISH". ALLOW FOR THICKNESS OF FINISHES.
CONTINUOUS NOMINAL LUMBER FIRE ALARM
EMERGENCY ACCESS WINDOWS
R1 OCCUPANCY (NFPA 72)
NOT REQUIRED
IBC Section 907.3
IBC Section 1029
CLG
COATG
CEILING
COATING
N
13. COORDINATE & PROVIDE BLOCKING / BACKING FOR MILLWORK & ITEMS ATTACHED OR MOUNTED TO
COILG COILING
WALLS OR CEILINGS. NIC NOT IN CONTRACT
DISCONTINUOUS NOMINAL LUMBER & FIRE RESISTIVE CONSTRUCTION CONC CONCRETE
NO (#) NUMBER
STRUCTURAL FRAME 2 HR IBC Table 601 CONST CONSTRUCTION
WOOD BLOCKING (INTERRUPTED MEMBER) BEARING WALLS (EXT.) 2 HR IBC Table 601
14. UNDERCUT DOORS TO CLEAR TOP OF FLOOR FINISHED BY 1/4 INCH, UNLESS NOTED OTHERWISE.
CONT CONTINUOUS(ATION)
NTS NOT TO SCALE
BEARING WALLS (INT.) 2 HR IBC Table 601 CONTR CONTRACT(OR)
INSULATION (LOOSE OR BATT) NON-BEARING WALLS (EXT.) 0 HR IBC Table 601 COV COVER O
NON-BEARING WALLS (INT.) 0 HR IBC Table 601 FIRE DEPARTMENT NOTES CMU CONCRETE MASONRY UNIT
FLOOR/CEILING ASSMEBLIES 2 HR IBC Table 601 OH OPPOSITE HAND
RIGID INSULAITON ROOF/CEILING ASSMEBLIES 1 HR IBC Table 601
D ORNA ORNAMENTAL
1. PROVIDE A PORTABLE FIRE EXTINGUISHER WITH A RATING OF NOT LESS THAN 2-A WITHIN 75 FOOT TRAVEL
SHAFT ENCLOSURES 2 HR IBC Table 707.3.10 + IBC section 713.1 OVFL OVERFLOW
DISTANCE TO ALL PORTIONS OF THE BUILDING ON EACH FLOOR, AND ADDITIONAL EXTINGUISHERS AS
STAIR ENCLOSURES 2 HR IBC Section 1023.1 OVHD OVERHEAD
GLAZING (LARGE SCALE) CORRIDOR WALLS R OCCUPANCY 0.5 HR IBC Table 1020.1
REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR OR BUILDING DEPARTMENT INSPECTOR. DBL DOUBLE
DEPT DEPARTMENT OPNG OPENING(S)
DWELLING UNIT SEPARATION 1 HR IBC Section 708.3 OPR OPERABLE
2. PROVIDE EXIT SIGN WITH 6" LETTERS OVER REQUIRED EXITS, WHERE SHOWN ON DRAWINGS, AND DES DESIGN(ED)
GYPSUM WALL BOARD FIRE-RESISTIVE JOINTS ALL RATED ASSEMBLIES NOT LESS THAN THE REQUIRED RESISTANCE OF THE ASSEMBLY IBC Section 715
ADDITIONAL SIGNS AS REQUIRED BY BUILDING DEPARTMENT INSPECTOR OR FIRE DEPARTMENT INSPECTOR. DET DETAIL
PENETRATION FIRE-STOPPING ALL RATED ASSEMBLIES / FIRE-RESISTANCE-RATED ASSEMBLIES IBC Section 714.4.1.1.2 04/24/19
PLASTER WITH LATH
FIRE-BLOCKING IBC Section 717.2
CONNECT EXIT SIGNS TO EMERGENCY POWER CIRCUITS. COMPLY WITH BUILDING CODES. DF
DIA
DRINKING FOUNTAIN
DIAMETER
P
DRAFT-STOPPING 717.3
3. PROVIDE EMERGENCY LIGHTING OF ONE-FOOT CANDLE AT FLOOR LEVEL. COMPLY WITH BUILDING CODES. DIFF DIFFUSER
FIRE-RATED DOORS REQUIRED AT RATED WALLS IBC Table 716.5 PTN PARTITION
DIM DIMENSION
FIRE-RATED WINDOWS REQUIRED AT RATED WALLS IBC Table 716.5 PED PEDESTRIAN
ACOUSTICAL TILE 4. MAINTAIN AISLES AT LEAST 44" WIDE AT PUBLIC AREAS DISP DISPENSER
PBD PARTICLE BOARD
SMOKE-ACTIVATED DOORS REQUIRED IBC Section 715.4.7.3
DIV DIVISION
SMOKE AND HEAT REMOVAL REQUIRED DRAFT CURTAIN AND SMOKE/HEAT VENTS IBC Table 910.3 PNL PANEL
5. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL DN DOWN
CARPET $ DOLLAR (US CURRENCY)
POLYST POLYSTYRENE
MEANS OF EGRESS KNOWLEDGE OR EFFORT. SPECIAL LOCKING DEVICE SHALL BE OF AN APPROVED TYPE. ALL DOORS SHALL PORT PORTABLE
HAVE AN APPROVED LEVER HANDLES. DR DOOR
ELEVATION HATCHES & SYMBOLS OCCUPANT LOAD REFERENCE SHEETS A0.10 - A0.14 IBC Table 1004.1.2 PREFIN PREFINISHED
DSCON DISCONNECT
MAXIMUM TRAVEL DISTANCE R-1 /A = 250'-0" + B = 300'-0" IBC Table 1017.2 PREFAB PREFABRICATED
6. STORAGE, DISPENSING OR USE OF ANY FLAMMABLE OR COMBUSTIBLE LIQUIDS, FLAMMABLE GAS AND DWR DRAWER
COMMON PATH OF EGRESS TRAVEL R-1/A = 75'-0" + B = 100'-0" PLAM PLASTIC LAMINATE
NUMBER OF EXITS REQUIRED REFERENCE SHEETS A0.10 - A0.14 IBC Table 1016.2 HAZARDOUS SUBSTANCES SHALL COMPLY WITH UNIFORM FIRE CODE REGULATIONS. PLAS PLASTER
STONE MAXIMUM DISTANCE BETWEEN EXITS 1/3rd THE LENGTH OF THE MAXIMUM DIAGONAL DIMENSION OF THE AREA SERVED IBC Section 1007.1.1 PLSTC PLASTIC
CORRIDOR WIDTH EGRESS: 44" MIN. OR THE TOTAL LOAD SERVED BY THE EGRESS MULTIPLIED BY 0.2 INCHES (WHICHEVER IS GREATER) / NON-EGRESS COMPONENTS: 44”
MIN. 36 MIN RESIDENTIAL UNITS
20.2 + IBC SECTION 1018.2 7. WOOD BLOCKING SHALL BE FIRE TREATED IN ACCORDANCE WITH APPLICABLE CODE REQUIREMENTS. E PLYWD PLYWOOD
BRICK OR CONCRETE BLOCK 8. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE HEARING IMPAIRED.
PRTECN PROTECTION
CORRIDOR HEIGHT 7’-6” MIN. IBC Section 1208.2 EJ EXPANSION JOINT
WOOD (FINISHED)
DEAD END CORRIDORS
ACCESSIBLE MEANS OF EGRESS
50’-0” MAX. R OCCUPANCY
ACCESSIBLE SPACES SHALL BE PROVIDED WITH NOT LESS THAN ONCE ACCESSIBLE MEANS OF EGRESS. WHERE MOR THAN ONE MEANS OF EGRESS ARE
IBC Section 1018.4, Exception 2
IBC Section 1009.1
FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT MORE THAN 60 FLASHES PER MINUTE. ELAST
ELEC
ELASTOMERIC
ELECTRICAL
R
REQUIRED BY SECTION 106.2 OR 10063 FROM ANY ACCESSIBLE SPACE, EACH ACCESSIBLE POERTION OF THE SPACE SHALL BE SERVED BY NOT LESS THAN 9. KNOX BOX FOR FIRE DEPARTMENT RAPID ENTRY SHALL BE INSTALLED PER JURISDICTION.
TWO ACCESSIBLE MEANS OF EGRESS EMBED EMBEDD(ED)(ING) RDR READER
GLASS EXTERIOR AREA OF ASSISTED REFUGE NOT REQUIERED IBC Section 1009.4 ENGR ENGINEER(ED) RECES RECESSED
NOTE: IF A FIRE ALARM MONITORING SYSTEM IS REUQIRED, LOCATIONS OF FIRE ALARM PANEL & STROBES ARE ENTR ENTRANCE
STAIR ENCLOSURE IBC Section 1022.9 TO BE COORDINATED WITH ARCHITECT PRIOR TO INSTALLATION. RECPT RECEPTACLE
ENCLOSURE PENETRATIONS NOT PERMITTED IBC Section 1023.5 EQ EQUAL REF REFER(ENCE)
STAIR WIDTH 44” IBC Section 1011.2 EQUIP EQUIPMENT REFL REFLECTED
EXIST EXISTING
CONSTRUCTION SYMBOLS STAIR HEADROOM
STAIR LANDING WIDTH
80"
NOT LESS THAN WIDTH OF STAIR
IBC Section 1011.3
IBC Section 1011.6
FINISH NOTES EXP JT EXPANSION JOINT
REFR
REQD
REFRIGERATOR
REQUIRED
ALLOWABLE LANDING REDUCTION BY DOORS 7” WHEN DOOR IS FULLY OPEN, 50% IN ANY OTHER POSITION IBC Section 1010.1.6 EXPS EXPOSE(D) RESIS RESIST(ANT)(IVE)
MAXIMUM VERTICAL RISE W/OUT LANDING 12' IBC Section 1011.8 1. ENSURE SURFACES TO RECEIVE FINISHES ARE CLEAN, TRUE, & FREE OF IRREGULARITIES. DO NOT EXT EXTERIOR REINF REINFORCE(D)(ING)(MENT)
0 COLUMN GRID STAIR TREADS
STAIR RISERS
11” MIN.
7” MAX. AND 4” MIN.
IBC Section 1011.5.2
IBC Section 1011.5.2
PROCEED WITH WORK UNTIL UNSATISFACTORY CONDITIONS HAVE BEEN CORRECTED. RESIL
RFG
RESILIENT
ROOFING
-- PARTITION TAG
HANDRAILS REQUIRED ON BOTH SIDES IBC Section 1011.11 F RM ROOM
HANDRAIL HEIGHT 34” MIN.; 38” MAX. IBC Section 1014.2 RO ROUGH OPENING
HANDRAIL PROJECTION 4.5” ON EACH SIDE IBC Section 1014.8 FAB FABRICATION
ELEVATION DATUM POINT HANDRAIL GRASPABILITY 1.25” DIAM. MIN.; 2 DIAM. MAX. IBC Section 1014.3 REFLECTED CEILING NOTES FD FLOOR DRAIN S
HANDRAIL EXTENSIONS EXTEND HORIZONTALLY 12” FROM TOP RISER, CONTINUE TO SLOPE FOR THE DEPTH OF ONE TREAD BEYOND BOTTOM RISER. IBC Section 1014.6 FE FIRE EXTINGUISHER

MARRIOTT AUTOGRAPH AT CRAIG RANCH


NAME GUARDRAILS REQUIRED AT WALKING SURFACES 30” A.F.F. IBC Section 1015.2
1. DESIGN SUSPENDED CEILING FRAMING SYSTEMS TO RESIST A LATERAL FORCE OF 20% OF THE WEIGHT OF FEC FIRE EXTINGUISHER CABINET SCR SCRIBE
NUMBER ROOM TAG GUARDRAIL HEIGHT 42" MIN. IBC Section 1015.3 FHC FIRE HOSE CABINET
THE CEILING ASSEMBLY & ANY LOADS TRIBUTARY TO THE SYSTEM. USE A MINIMUM WIEGHT OF 5 POUNDS SECUR SECURITY
GUARDRAIL OPENINGS 3-3/4” MAX. (4” DIAM. SPHERE SHALL NOT PASS THROUGH) IBC Section 1015.4 FIN FINISH
PER SQUARE FOOT TO DETERMINE THE LATERAL FORCE. SF SQUARE FEET
Unit Type SIGNAGE REQUIRED IBC Section 1023.9 FLDG FOLDING SGL SINGLE
###
UNIT TAG ELEVATOR OPENINGS TAS TABLE 407.4.1
2. WHERE CEILING LOADS ARE NOT TO EXCEED 5 POUNDS PER SQUARE FOOT AND WHERE PARTITIONS ARE FPLC FIREPLACE SHORG SHORING
ELEVATOR CAB SIZE TAS TABLE 407.4.1 + IBC Section 3002.4 FR FIRE RAT(ING)(ED)
NOT CONNECTED TO THE CEILING SYSTEM, THE FOLLOWING BRACING METHODS MAY BE EMPLOYED: SIM SIMILAR
SIGNAGE TAS TABLE 407.2.3 + IBC Section 3002.3 FR,G FRAMING SS STAINLESS STEEL
# CAB CONTROLS TAS TABLE 407.4
DOOR TAG A. PROVIDE LATERAL SUPPORT BY FOUR WIRES OF MINIMUM NO. 12 GUAGE SPLAYED IN FOUR FXD FIXED STD STANDARD
OCCUPANT EGRESS ELEVATOR FXTR FIXTURE
DIRECTIONS 90 DEGREES APART, & CONNECTED TO THE MAIN RUNNER WITHIN 2" OF THE CROSS RUNNER & STL STEEL
FIRE VESTIBULE FLR FLOOR(ING)
ALIGN ALIGN WITH ESTABLISHED TO THE STRUCTURE ABOVE AT AN ANGLE NOT EXCEEDING 45 DEGREES FROM THE PLANE OF THE CEILING. STRFR STOREFRONT
PROVIDE THESE LATERAL SUPPORT POINTS 12 FEET ON CENTER IN EACH DIRECTION WITH THE FIRST POINT FURN FURNITURE STRUCT STRUCTURAL
SURFACES INTERIOR ENVIRONMENT
WITHIN 4' FROM EACH WALL. FWC FABRIC WALL COVERING SURF SURFACE
NATURAL VENTILATION MIN. 4% OF FLOOR AREA BEING VENTILATED IBC Section 1203.5.1
-?- SUSP SUSPENDED
SHEET KEYNOTE NATURAL LIGHT MIN. 8% OF FLOOR AREA BEING SERVED IBC Section 1205.2 or artificial lighting accordance with 1205.2
B. ALLOW FOR LATERAL MOVEMENT OF THE SYSTEM. ATTACH MAIN RUNNERS AND CROSS RUNNERS AT SYS SYSTEM(S)
SPACE DIMENSIONS MIN. 7’-0” IN ANY DIRECTION, MIN. 3’-0” CLEAR BETWEEN COUNTER FRONTS AND FACE OF APPLIANCES IBC Section 1205.3
-- WINDOW MARK
CEILING HEIGHTS MIN. 7’-6” FOR ALL HABITABLE SPACES AND EGRESS COMPONENTS, MIN. 7’-0” FOR KITCHENS, BATHS, AND STORAGE IBC Section 1208.1 TWO ADJACENT WALLS; MAINTAIN CLEARANCE BETWEEN THE WALL AND THE RUNNERS AT THE OTHER
TWO WALLS.
G

8091 Collin McKinney Pkwy,


INTERIOR FINISHES GA GAUGE
-- REVISION REFERENCE EXIT ENCLOSURES AND PASSAGEWAYS CLASS C FLAMESPREAD RATING IBC Table 803.11 C. PROVIDE VERTICAL SUPPORT ENDS AS REQUIRED BY BUILDING CODES. IN ADDITION, VERTICALLY GD GRAD(E)(ING) T

McKinney, Texas 75070


SUPPORT ENDS OF RUNNERS WITHIN 8" OF DISCONTINUITIES SUCH AS MAY OCCUR WHERE THE CEILING GFRC GLASS FIBER REINF.

CRAIG RANCH HOTEL, LLC


CORRIDORS CLASS C FLAMESPREAD RATING IBC Table 803.11
ROOMS AND ENCLOSED SPACES CLASS C FLAMESPREAD RATING IBC Table 803.11 IS INTERRUPTED BY A WALL CONCRETE THK THICK
# GFRG GLASS FIBER REINF. GYPSUM
SECTION INDENTIFIER TLT TOILET
SHEET ROOFING D. SUPPORT LIGHT FIXTURES & AIR DIFFUSERS DIRECTLY TO THE STRUCTURE ABOVE WITH WIRES. GFRP GLASS FIBER REINF. PLASTER TRAF TRAFFIC
SIM FIRE CLASSIFICATION TYPE IB: CLASS B IBC Table 1505.1 GL GLASS TRANS TRANSPARENT
# ATTIC VENTILATION N/A 3. LOCATE REGISTERS & LIGHTING FIXTURES WITHIN GRID LINES. CENTER SPEAKERS, RECESSED FIXTURES, GR GRAD(E)(ING) TRTD TREATED
SHEET DETAIL INDENTIFIER ROOF COVERING WHITE THERMOPLASTIC SINGLE PLY MEMBRANE IBC Section 1507.13 & SIMILIAR CEILING ELEMENTS IN ACOUSTICAL UNITS, UNLESS NOTED OTHERWISE. GYP GYPSUM T&G TONGUE & GROOVE
ROOF SLOPE ONE-FOURTH UNIT VERTICAL IN 12 UNITS HORIZONTAL (2%) MIN. IBC Section 1507.13.1 TYP TYPICAL
EQUIPMENT ON ROOF YES 4. THE FINISH OF HVAC DIFFUSERS, DRAPERY POCKETS, & SPEAKER GRILLES SHALL MATCH THEIR ADJACENT

FE
FIRE EXTINGUISHER WITHOUT CABINET FINISH, UNLESS NOTED OTHERWISE. H U
ACCESSIBILITY

FIRE EXTINGUISHER CABINET ON WALL ACCESSIBLE PARKING SPACES REQUIRED IBC Table 1106.1. HD HEAD UNDRLAY UNDERLAYMENT
ACCESSIBLE ROUTE 36” MIN.; 32” MIN. CLEAR @ DOORS HDWD HARDWOOD UTIL UTILITY

CENTERLINE
MANUEVERING CLEARANCES
CLEAR FLOOR SPACE
60” DIAM.
30” x 48”
POWER & COMMUNICATION NOTES HDWR
HM
HARDWARE
HOLLOW METAL
UNO
UON
UNLESS NOTED OTHERWISE
UNLESS OTHERWISE NOTED
DOOR STRIKE CLEARANCES 12” MIN. PUSH SIDE; 18” MIN. PULL SIDE HORIZ HORIZONTAL
# 1. PRIOR TO CORING SLAB, REVIEW LOCATIONS WITH ARCHITECT & COORDINATE LOCATIONS WITH OWNER.
EXTERIOR ELEVATION HVAC HEATING, VENTILATION, &
SHEET ENERGY AIR CONDITIONING
ROOF - INSULATION ENTIRELY ABOVE DECK R25 ci IECC TABLE C402.1.3 2. COORDINATE INSTALLATION OF TELECOMMUNICATIONS, DATA & SECURITY SYSTEMS.
# / SHEET INTERIOR ELEVATION WALLS - METAL FRAMED R-13 + R-7.5 ci IECC TABLE C402.1.3 I V
FLOORS - JOIST/FRAMING R-30 IECC TABLE C402.1.3 3. VERIFY EQUIPMENT SPECIFICATIONS, POWER AND INSTALLATION REQUIREMENTS WITH MANUFACTURER
-- GLAZING ELEVATION DOORS - OPAQUE SWINGING R-4.75 IECC TABLE C402.1.3 TO ENSURE PROPER FIT & FUNCTION. INFO INFORMATION VEH VEHICLE
INSTRUM INSTRUMENT(ATION) VERT VERTICAL
HIGHRISE CODE 4. VERIFY MOUNTING REQUIREMENTS OF ELECTRICAL, TELEPHONE & OTHER EQUIPMENT. INSUL INSULATION VIF VERIFY IN FIELD
RF FINISH TAG HIGHRISE CODE REFERENCE SHEETS A0.10 - A0.14 INTLK INTERLOCK(ING)
5. GANG ADJACENT LIGHT SWITCHES & COVER WITH A SINGLE PLATE. INT INTERIOR
?
-- KEYNOTE TAG INFILTR INFILTRATION
6. IDENTIFY DEDICATED OR ISOLATED GROUND ELECTRICAL OUTLETS WITH A RED DOT.
?
-- KEYNOTE TAG 7. MOUNT STANDARD WALL OUTLETS, SWITCHES & THERMOSTATS AT HEIGHTS REQUIRED BY ADA & TAS J W
GUIDELINES, UNLESS NOTED OTHERWISE. WHEN THERMOSTATS AND LIGHT SWITCH OCCUR TOGETHER,
NAME JAN JANITOR W/ WITH
ELEVATION ELEVATION LEVEL INSTALL BOTH ALIGNED HORIZONTALLY WITH CENTER LINE AT +3'-2" ABOVE FINISHED FLOOR.
JT JOINT WC WATER CLOSET
8. INDICATED DIMENSIONS ARE TO THE CENTER LINE OF OUTLET OR SWITCH, OR CLUSTER OF OUTLETS OR WD WOOD
# / SHEET DETAIL REFERENCE WDW WINDOW
SWITCHES, UNLESS OTHERWISE NOTED.
W/O WITHOUT
-- WALL TAG 9. INSTALL OUTLETS ON OPPOSITE SIDES OF PARTITIONS IN SEPARATE STUD CAVITIES. DO NOT INSTALL WT WEIGHT
BACK-TO-BACK. WTRPRF WATERPROOFING c 2019
MERRIMAN ANDERSON /
-- WINDOW TAG ARCHITECTS, INC.
10. PROVIDE MATCHING COVER PLATES, RECEPTACLES & RELATED ITEMS. PROVIDE ONE-PIECE TYPE GANG
COVER PLATES, UNLESS NOTED OTHERWISE. REVISIONS:

PROJECT NUMBER:

maa2017183
ISSUE DATE:

04/24/2019
SHEET NAME:

SYMBOLS, GENERAL
NOTES, ABBREVIATIONS
& CODE ANALYSIS
4/24/2019 3:34:03 PM

SHEET NUMBER: