1.0 ALL ELECTRONICS WORKS HERE IN SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE
LATEST EDITION OF THE PHILIPPINE ELECTRONICS CODE, THE RULES AND REGULATIONS OF THE
LOCAL ENFORCING AUTHORITIES AND THE REQUIREMENTS OF THE UTILITY TELEPHONE COMPANY. NOTES :
2.0 ALL ELECTRONICS WORKS HERE IN INCLUDED SHALL BE EXECUTED BY PERSONNEL WITH ELECTRICAL 1.) THIS DRAWING IS SCHEMATIC REPRESENTATION OF SYSTEM ONLY.
TENDERS TO DETAIL COMPLIANT OFFER BASED ON MANUFACTURER'S
EXPERIENCE UNDER THE DIRECT SUPERVISION OF A FULL TIME LICENSED ELECTRONICS ENGINEER, SYSTEM & WIRING METHODS RECOMMENDATION.
WORKS SHALL BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY FINISHED. 2.) POWER SUPPLY TO EACH LDC MUST BE CONNECTED TO EMERGENCY POWER EC-501
ENGINEERING SG
I NATURE DATE COMMENTS
3.0 THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF TAPPING POINT FOR 3.) WIRING INSTALLATION (CEILING CONCEALED, EMBEDDED, EXPOSED OR
CONNECTION TO COMMUNICATION SUPPLY. SURFACED) SHALL BE USED RSC, 15mmØ MINIMUM.
4.0 ALL MATERIALS SHALL BE BRAND NEW & SHALL CONFORM WITH THE PROVISIONS OF THE UNDER 4.) WIRING FROM TEL/DATA PORT TO LDC MUST BE CAT6e NEATLY BUNDLED IN
WRITERS LABORATORIES INC., IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED. CABLE TRAY USING NYLON CABLE TIE
5.0 ALL CONDUITS MUST BE PROTECTED AGAINST DAMAGES BY THE ENTRANCE OF WATER & FOREIGN 5.) LDC's ARE WALL MOUNTED LOCATED 2 FEET BELOW CEILING.
MATTERS DURING CONSTRUCTION. ALL ENDS OF CONDUITS SHALL BE PLUGGED TO EXCLUDE
MOISTURE AND DUST IMMEDIATELY AFTER THE CONDUITS ARE PLACED.
ENS SYSTEM SHALL BE HONEYWELL BRAND
6.0 UNLESS OTHERWISE SPECIFIED, ALL ELECTRONICS WIRING INSTALLATION SHALL BE USED RSC. PROVIDE MODEL NO. CONTROL SIGNALS FROM
THE MINIMUM SIZE OF CONDUIT SHALL BE 15mmØ. FIRE ALARM SYSTEM
7.0 ALL RACEWAYS, WALL & FLOOR PENETRATIONS SHALL BE PROVIDED WITH FIRE BARRIER OF THE FIRE MAN'S MICROPHONE
APPROVED TYPE. LOCATED AT RECEPTION AREA (SECOND FLOOR)
8.0 ALL OUTLET BOXES SHALL BE GALVANIZED GAGE NO. 16, DEEP TYPE WITH FACTORY KNOCKOUTS.
ZONE PAGING MICROPHONE LOCATED AT RECEPTION
PULLBOXES SHALL BE USED WHEN APPLICABLE FOR EASY PULLING OF WIRES AND SHALL BE IN AREA (SECOND FLOOR)
ACCORDANCE WITH THE PHILIPPINE ELECTRICAL CODE REQUIREMENT.
PREFERRED BRAND FOR JUNCTION, PULLBOX OR UTILITY SQUARE BOXES SHALL BE FUMACO, AMCO,
TIMO OR APPROVED EQUAL.
SECOND FLOOR
9.0 MOUNTING HEIGHTS OF DEVICES SHALL BE:
(SUBJECT TO ARCHITECT'S APPROVAL PRIOR TO INSTALLATION) 1. is the network controller interface capable of providing
the desired power amplification for the Microphones? if not
DATA OUTLET- 0.30M ABOVE FINISHED FLOOR TO CENTER OF DEVICE pre-amplifier for the remote microphones at the reception
are to be provided.
10.0 ALL SPEAKER WIRING SHALL BE 2-0.75 SQ.MM SHIELDED SPEAKER WIRE. 2. wall mounted speaker does not have the wattage as well as
the amplifiers. contractor to provide data for proper identification UPPER G/F
11.0 NETWORK CABLES/CONDUIT SHALL HAVE A MINIMUM DISTANCE OF 0.3M FROM POWER CONDUIT to be used in the quantifications of all devices to be used.
WHEN LAID PARALLEL & MUST RUN PERPENDICULAR TO THE STEEL CONDUIT WHEN CUTTING
ACROSS A POWER LINE.
12.0 THE PLANS AS DRAWN ARE BASED UPON THE ARCHITECTURAL PLANS & THE DETAILS & SHOWN
LOWER G/F
CONDITION AS ACCURATELY AS IT IS POSSIBLE TO INDICATE THEM IN SCALE. THE PLANS ARE ESH
DIAGRAMMATICAL AND DOES NOT NECESSARILY SHOW ALL FITTINGS NECESSARY TO FIT TO THE
BUILDING CONDITIONS. THE LOCATIONS OF OUTLETS, APPARATUS AND APPLIANCES SHOWN ON 1 PA & BGM RISER DIAGRAM
THE PLANS ARE APPROXIMATE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THEIR ECE-1 SCALE: NTS
PROPER LOCATION IN ORDER TO MAKE THEM FIT WITH THE ARCHITECTURAL DETAILS AND
INSTRUCTIONS FROM THE ENGINEER'S REPRESENTATIVE AT THE SITE. LDC1
PB
LDC2
POE SWITCH
Electronics Plans shall be signed and sealed by a Professional Electronics Engineer per R.A. 9292. FOR APPROVAL
SUSALUM CORPORATION PHILIP P. PANGILINAN, PEE / CEA TIPI TIPI
SAL - Bldg. Sta Rosa - Tagaytay Highway
Sitio Muzon, Brgy. Putingkahoy, Silang, Cavite
PROFESSIONAL ELECTRICAL ENGINEER
DESIGN AND BUILD FOR OFFICE AND AUXILIARY GENERAL NOTES,
Philippines 4118
4895 5566791 STOCKROOM BUILDING SYMBOLS & LEGENDS, & RISER ECE-1
Trunkline No. 63-49-502-9931 to 32
Direct Line: 63-49-502-9924 400-321-713 Quezon City DIAGRAMS
Fax No. 63-49-502-9925 RICHARD CACAL
Email: susalum@susalum.com.ph 01/08/2024 LOAKAN ROAD, PEZA, BAGUIO CITY FACILITIES DIRECTOR
X8 X9 X10
passing a certain size. this is to allow reviewer
idea if the conduits size to be used is still X11 X12 X13
acceptable in the work area.
GENERAL NOTES:
TTC is not
shown in = CCTV CAMERA
the SLD
= WALL- MOUNTED SPEAKER
Y5
ELECTRICAL ROOM
VENDO
AREA
5000
LEGAL COM.
Y4 MR-6
ESH
5000
MR-7
20000
Y3
MR-5 PLANNING
OTHERS
5000
Y2
PAYROLL & FINANCE
EXIT
SUSALUM CORPORATION
SAL - Bldg. Sta Rosa - Tagaytay Highway
PHILIP P. PANGILINAN, PEE / CEA
PROFESSIONAL ELECTRICAL ENGINEER
TIPI TIPI
Sitio Muzon, Brgy. Putingkahoy, Silang, Cavite DESIGN AND BUILD FOR OFFICE AND
Philippines 4118
4895 5566791 STOCKROOM BUILDING AUXILIARY LAYOUT PLAN - LOWER GND FLR ECE-2
Trunkline No. 63-49-502-9931 to 32
Direct Line: 63-49-502-9924 400-321-713 Quezon City
Fax No. 63-49-502-9925 RICHARD CACAL
Email: susalum@susalum.com.ph 01/08/2024 LOAKAN ROAD, PEZA, BAGUIO CITY FACILITIES DIRECTOR
same comments
TEXAS INSTRUMENT
X1 X2 X3 X4 X5 X6 X7 X8 X9 X10GENERAL NOTES: X11 X12 X13
75000
= TELEPHONE AND
DATA OUTLET = WALL-MOUNTED
6000 6000 6000 6000 6000 6000 6000
6000 6000 6000 6000
SPEAKER 6000
TRANSFORMER
TRANSFORMER
UNREG
UPS
5000
Y4
5000
Y3
20000
5000
Y2
5000
Y1
WALKWAY
ESH
= CCTV CAMERA
OTHERS
Y5
IDF ROOM
IT ACE VENDO
VENDO AREA AREA
ELECTRICAL ROOM MR-4
P2P
5000
P2P
Y4 MR-2
EXIT
5000
STAIR
MR-1
Y3
133.27
5000
MR-3
LOCAL IT
Y2
GENDER
NEUTRAL
IT ACE
XID/FAST
LOBBY
5000
Y1
STAIR