CONSULTANTS GENERAL NOTES 2018 INTERNATIONAL RESIDENTIAL CODE

49201 SQUARE FOOTAGE CALC. SHEET INDEX PLAN ISSUE DATES


2021.10.01 - TOWN OF MEAD PLANNING SUBMITTAL
PERMIT DRAWINGS: PROVIDE DAMPPROOFING OR WATERPROOFING OF ALL 2021.12.28 - CENTURY FINAL REVIEW SET
LOWER LEVEL IS CALCULATED FROM INTERIOR SIDE OF FNDN. WALL & INCLUDES STAIRS.
THE ARCHITECT HAS BEEN CONTRACTED TO PROVIDED FOUNDATIONS PER SOILS REPORT AND/OR SECTION R406. 2022.02.28 - TOWN OF MEAD PLANNING RESUBMITTAL
GODDEN | SUDIK ARCHITECTS LIMITED SERVICES. IN REGARDS TO THE CONTRACT A0.0 COVER SHEET
MAIN LEVEL IS CALCULATED FROM EXTERIOR FRAME OF STUD WALL & INCLUDES STAIRS / EXCLUDES OPENINGS TO BELOW. 2022.03.30 - TOWN OF MEAD PERMIT SET
5975 S. QUEBEC STREET, SUITE 250 DOCUMENTS, THE ARCHITECT WILL PREPARE THIS SET OF
CLASS I, II OR III VAPOR RETARDERS ARE REQUIRED ON THE
PERMIT DRAWINGS ONLY. ALL OTHER COMPONENTS OF THE
CENTENNIAL, CO 80111
303-455-4437 - OFFICE
CONTRACT DOCUMENTS ARE BY THE BUILDER OR THE
BUILDERS CONSULTANTS INCLUDING:
INTERIOR SIDE OF FRAME WALLS IN ZONE 5.
THE FOLLOWING SHALL BE DEEMED TO MEET THE CLASS
UPPER LEVEL IS CALCULATED FROM EXTERIOR FRAME OF STUD WALL & EXCLUDES STAIRS / EXCLUDES OPENINGS TO BELOW.
FINISHED
Godden|Sudik
A. STRUCTURAL, MECHANICAL, CIVIL AND ALL OTHER
SPECIFIED:
CLASS I: SHEET POLYETHYLENE, UNPERFORATED
AREA SCHEDULE ELEV. 'A' ELEV. 'B' ELEV. 'C' A R C H I T E C T S
TYPES OF ENGINEERING SERVICES. A1.0 LOWER LEVEL FLOOR PLAN - 'A'
ALUMINUM FOIL. MAIN LEVEL 1,257 SQ. FT. 1,257 SQ. FT. 1,257 SQ. FT. SEE WHAT COULD BE
B. FINISHES & FIXTURE SELECTIONS.
CLASS II: KRAFT-FACED FIBERGLASS BATTS. UPPER LEVEL 1,471 SQ. FT. 1,471 SQ. FT. 1,471 SQ. FT.
C. PROJECT SPECIFICATIONS. A1.1 LOWER LEVEL FLOOR PLAN - 'B'
CLASS III: LATEX OR ENAMEL PAINT.
D. SOILS TEST & ENVIRONMENTAL REPORTS.
TOTAL FINISHED 2,728 SQ. FT. 2,728 SQ. FT. 2,728 SQ. FT.
E. SITE SURVEYS AND PLOT PLANS. A1.2 LOWER LEVEL FLOOR PLAN - 'C'
EV STUDIO WALL FLASHING:
5335 W. 48TH AVENUE, SUITE 300 APPROVED CORROSION-RESISTANT FLASHING SHALL BE UNFINISHED A1.3 OPT. FULL LOWER LEVEL FLOOR PLAN
THE ARCHITECT ASSUMES NO RESPONSIBILITY FOR THE
DENVER, CO 80212 OWNER'S SELECTION OF ANY SPECIFIC PRODUCT, APPLIED IN A MANNER TO PREVENT ENTRY OF WATER INTO LOWER LEVEL 877 SQ. FT. 877 SQ. FT. 877 SQ. FT.
MANUFACTURER, OR METHOD OF INSTALLATION NOT THE WALL CAVITY OR PENETRATION OF WATER TO THE CRAWL SPACE 289 SQ. FT. 289 SQ. FT. 289 SQ. FT. A2.0 MAIN LEVEL FLOOR PLAN - 'A'
303-670-7242 - OFFICE BUILDING STRUCTURAL FRAMING COMPONENTS. THE
DOCUMENTED IN THE CONSTRUCTION DOCUMENTS. THE
ARCHITECT SHALL NOT HAVE CONTROL OVER OR CHARGE OF FLASHING SHALL EXTEND TO THE SURFACE OF THE TOTAL UNFINISHED 1,166 SQ. FT. 1,166 SQ. FT. 1,166 SQ. FT. A2.1 MAIN LEVEL FLOOR PLAN - 'B'
AND SHALL NOT BE RESPONSIBLE FOR CONSTRUCTION EXTERIOR WALL FINISH. APPROVED CORROSION-RESISTANT
MEANS, METHODS, TECHNIQUES, SEQUENCES OR FLASHING SHALL BE INSTALLED AT ALL OF THE FOLLOWING A2.2 MAIN LEVEL FLOOR PLAN - 'C'
UNCONDITIONED & EXTERIOR
PROCEDURES, OR FOR SAFETY PRECAUTIONS AND LOCATIONS PER R703:
3-BAY TANDEM GARAGE 612 SQ. FT. 612 SQ. FT. 612 SQ. FT.
PROGRAMS IN CONNECTION WITH THE WORK. 1. EXTERIOR WINDOW AND DOOR OPENING.
2. AT THE INTERSECTION OF CHIMNEYS OR OTHER COVERED FRONT PORCH 85 SQ. FT. 85 SQ. FT. 85 SQ. FT. A2.3 MAIN LEVEL FLOOR PLAN OPTIONS REVISION LOG
MASONRY CONSTRUCTION W/ FRAME OR STUCCO UPPER LEVEL FLOOR PLAN - 'A' & OPTION
A3.0
CONSTRUCTION PHASE SERVICES: WALLS, W/ PROJECTING LIPS ON BOTH SIDES UNDER
OPTIONS (ADDS ADDITIONAL S.F.)
THE ARCHITECT IS NOT CONTRACTED FOR CONSTRUCTION STUCCO COPINGS.
OPT. FULL LOWER LEVEL (UNFINISHED) 1,155 SQ. FT. 1,155 SQ. FT. 1,155 SQ. FT. A3.1 UPPER LEVEL FLOOR PLAN - 'B'
PHASE SERVICES INCLUDING: 3. UNDER AND AT THE ENDS OF MASONRY, WOOD OR
A. REVIEW OF SHOP DRAWING AND PRODUCT METAL COPINGS AND SILLS. OPT. PATIO 120 SQ. FT. 120 SQ. FT. 120 SQ. FT.
SUBMITTALS. 4. CONTINUOUSLY ABOVE ALL PROJECTING WOOD OR OPT. EXT. COVERED PATIO 230 SQ. FT. 230 SQ. FT. 230 SQ. FT. A3.2 UPPER LEVEL FLOOR PLAN - 'C'
B. CONSTRUCTION OBSERVATIONS. HARDBOARD/FIBER-CEMENT TRIM.
C. ADMINISTRATION OF THE CONSTRUCTION CONTRACT 5. WHERE EXTERIOR PORCHES, DECKS, OR STAIRS ATTACH
INCLUDING PAYMENT APPLICATIONS. TO A WALL OR FLOOR ASSEMBLY OF WOOD-FRAME
CONSTRUCTION.
6. AT WALL AND ROOF INTERSECTIONS.
CLARIFICATIONS & RFI'S: 7. AT BUILT-IN GUTTERS. A4.0A ROOF PLAN & OPT. - 'A'
IN THE EVENT THAT ADDITIONAL DETAIL OR GUIDANCE IS
NEEDED BY THE OWNER / BUILDER, CONTRACTOR OR A4.0B ROOF PLAN & OPT. - 'B'
SUBCONTRACTOR FOR CONSTRUCTION OF ANY ASPECT OF ROOF FLASHING:
THE PROJECT, THEY SHALL IMMEDIATELY NOTIFY THE FLASHINGS SHALL BE INSTALLED IN A MANNER THAT
A4.0C ROOF PLAN & OPT. - 'C'
ARCHITECT. FAILURE TO GIVE A SIMPLE NOTICE SHALL PREVENTS MOISTURE FROM ENTERING THE WALL AND ROOF
RELIEVE THE ARCHITECT OF RESPONSIBILITY FOR THE THROUGH JOINTS IN COPINGS, THROUGH MOISTURE
A5.0A EXTERIOR ELEVATIONS - 'A'
PERMEABLE MATERIALS AND AT INTERSECTIONS WITH
CONSEQUENCES. ANY DISCREPANCY OR AMBIGUITY
DISCOVERED BY THE USE OF THESE PLANS SHALL BE PARAPET WALLS AND OTHER PENETRATIONS THROUGH THE
ROOF PLANE INCLUDING THE FOLLOWING LOCATIONS PER A5.1A EXTERIOR ELEVATIONS - 'A'
REPORTED IMMEDIATELY TO THE ARCHITECT. CHANGES
R903 AND R905:
MADE FROM THE PLANS WITHOUT THE CONSENT OF THE A5.2A OPT. EXT. COVERED PATIO - 'A'
1. WALL AND ROOF INTERSECTIONS.
ARCHITECT ARE UNAUTHORIZED AND SHALL RELIEVE THE
2. WHEREVER THERE IS A CHANGE IN ROOF SLOPE OR
ARCHITECT OF RESPONSIBILITY FOR ALL CONSEQUENCES A5.3A ENHANCED EXTERIOR ELEVATIONS - 'A'
DIRECTION.
ARRIVING OUT OF SUCH CHANGES.
3. AROUND ROOF OPENINGS.
A5.4A ENHANCED EXTERIOR ELEVATIONS - 'A'

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


PROJECT TO BE BUILT FROM "CONSTRUCTION ISSUE"
THE BUILDING THERMAL ENVELOPE SHALL BE DURABLY A5.5A ENHANCED OPT. EXT. COVERED PATIO - 'A'
SET OF DRAWINGS.
SEALED TO LIMIT INFILTRATION. THE SEALING METHODS
ALL DIMENSIONS ARE TO FACE OF STUD UNLESS NOTED BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR A5.6A EXTERIOR DETAILS - 'A'
OTHERWISE. DIMENSIONS TAKE PRECEDENCE OVER DIFFERENTIAL EXPANSION AND CONTRACTION. RE: N1102.4.
DRAWING - DO NOT SCALE. A5.0B EXTERIOR ELEVATIONS - 'B'
WHERE NECESSARY, OR AS DIRECTED BY CONTRACTOR,
PROVIDE EXTRUDED POLYSTYRENE IN LIEU OF BATT A5.1B EXTERIOR ELEVATIONS - 'B'
INSULATION, BEHIND, BENEATH, OR ADJACENT TO PLUMBING,
A5.2B OPT. EXT. COVERED PATIO - 'B'

PHONE: 303-770-8300
CURRENTLY ADOPTED CODES: MECHANICAL, AND ELECTRICAL SUPPLIES, RETURNS, AND
• INTERNATIONAL RESIDENTIAL CODE, 2018 EDITION. OTHER DISTRIBUTION LINES AND FIXTURES TO ENSURE THE
• INTERNATIONAL ENERGY CONSERVATION CODE, 2012 MINIMUM INSULATION VALUES ARE STRICTLY ADHERED TO IN A5.3B ENHANCED EXTERIOR ELEVATIONS - 'B'
EDITION. ALL LOCATIONS. IN ALL INACCESSIBLE OR ENCLOSED AREAS
• NATIONAL ELECTRICAL CODE, 2020 EDITION (NFPA 70). OR AREAS THAT MAY BE INACCESSIBLE OR MAY BE A5.4B ENHANCED EXTERIOR ELEVATIONS - 'B'
• TOWN OF MEAD LOCAL AMENDMENTS ENCLOSED, PLACE EXTRUDED POLYSTYRENE INSULATION
IMMEDIATELY PRIOR TO PLACING THE PLUMBING, A5.5B ENHANCED OPT. EXT. COVERED PATIO - 'B'
MECHANICAL, AND ELECTRICAL RUNS.
REFERENCED STANDARDS: A5.6B EXTERIOR DETAILS - 'B'
AS DETAILED IN IRC CHAPTER 44 AND AS SPECIFIED IN
SECTION R102.4, NUMEROUS REQUIREMENTS FOR INSULATE ALL CANTILEVERED FLOORS WITH BATT A5.0C EXTERIOR ELEVATIONS - 'C'
PRODUCTS AND INSTALLATION METHODS ARE SPECIFIED BY INSULATION, SUFFICIENT TO FILL THE FRAMING CAVITY AND
THE IRC. WHEN NOT SPECIFIED BY THESE PERMIT DRAWINGS, PROVIDE CLASS I, II OR III VAPOR RETARDERS ON THE A5.1C EXTERIOR ELEVATIONS - 'C'
IT IS THE RESPONSIBILITY OF THE BUILDER / CONTRACTOR INTERIOR SIDE OF FRAME.
AND ALL SUBCONTRACTORS TO VERIFY COMPLIANCE WITH A5.2C OPT. EXT. COVERED PATIO - 'C'
THESE REFERENCED STANDARDS. THE BUILDER /
CONTRACTOR AND/OR THE SUBCONTRACTOR SHALL
THE TABLE BELOW LISTS THE PRESCRIPTIVE PATH A5.3C ENHANCED EXTERIOR ELEVATIONS - 'C'
IMMEDIATELY NOTIFY THE ARCHITECT IF ANY PORTION OF
THE DRAWINGS CONTRADICT THE REFERENCED STANDARDS. INSULATION VALUES (CODE MINIMUM). REFER TO THE
PROJECT ENERGY REPORT FOR ADDITIONAL INFORMATION. A5.4C ENHANCED EXTERIOR ELEVATIONS - 'C'
ACTUAL ENERGY REPORT VALUES SHALL SUPERCEDE ANY
MANUFACTURER'S INSTRUCTIONS AND RECOMMENDATIONS: INSULATION VALUES LISTED HERE: A5.5C ENHANCED OPT. EXT. COVERED PATIO - 'C'
THE BUILDER / CONTRACTOR AND/OR THE SUB-
CONTRACTORS SHALL FOLLOW ALL MFG. INSTRUCTIONS AND A5.6C EXTERIOR DETAILS - 'C'
EXTERIOR WOOD FRAMED WALLS (CAVITY) R-20
RECOMMENDATIONS. IF ANY PORTION OF THE DRAWINGS
CONTRADICT THE MANUFACTURERS INSTRUCTIONS, THE CEILINGS UNDER UNCONDITIONED SPACE R-49
BUILDER/ CONTRACTOR AND/OR THE SUBCONTRACTORS
SHALL IMMEDIATELY NOTIFY THE ARCHITECT. FLOORS OVER UNCONDITIOED SPACE (CAVITY) R-30
EXTERIOR BASEMENT WALLS (CONT./CAVITY) R15/19
A6.0 BUILDING SECTIONS
WINDOW U-FACTOR 0.30

SOILS REPORT: A6.1 THERMAL ENVELOPE DIAGRAMS


PROVIDE SITE PREPARATION AS SPECIFIED BY THE SOILS
ENGINEER REPORT INCLUDING A FOUNDATION DRAINAGE A7.0 COMMON DETAILS - WINDOW FLASHING
SYSTEM.
ALL WINDOWS ARE TO BE WEATHER-STRIPPED AND DOUBLE A7.1 COMMON DETAILS - WINDOW FLASHING
GLAZED. FRAME MATERIAL PER BUILDER.
PROVIDE A MINIMUM CLEARANCE OF 6" FROM ALL EXTERIOR A7.2 COMMON DETAILS - WINDOW FLASHING
WALL COVERINGS (EXCEPT 4" FOR MASONRY VENEER) TO
PROVIDE TEMPERED GLASS PER IRC SECTION R308.4 WHEN:
THE TOP OF GRADE. A7.3 COMMON DETAILS - WINDOW FLASHING
A. GLAZING IN ALL FIXED AND OPERABLE PANELS OF
SWINGING, SLIDING AND BIFOLD DOORS.
PROVIDE A MINIMUM CLEARANCE OF 8" FROM THE B. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANEL A7.4 COMMON DETAILS - FIBER CEMENT
NON-TREATED BASE OF WOOD FRAMING TO THE TOP OF ADJACENT TO A DOOR WHERE THE NEAREST VERTICAL
ADJACENT GRADE. EDGE IS WITHIN A 24" ARC OF THE DOOR IN A CLOSED A7.5 COMMON DETAILS - FIBER CEMENT
POSITION & WHOSE BOTTOM EDGE IS LESS THAN 60"
ABOVE THE FLOOR/WALKING SURFACE PER R308.4.2. A7.6 COMMON DETAILS - FIBER CEMENT
SLOPE GRADE PER THE SOILS REPORT OR A MINIMUM 10% C. GLAZING IN AN INDIVIDUAL FIXED OR OPERABLE PANE
AWAY FROM THE STRUCTURE FOR THE FIRST 10 FEET THAT MEETS OF THE FOLLOWING CONDITIONS: A7.7 COMMON DETAILS - ADH. MASONRY
DISTANCE. IMPERVIOUS SURFACES MAY BE SLOPED A MINIMUM 1. EXPOSED AREA OF AN INDIVIDUAL PANE IS LARGER
2.5% AWAY FROM THE STRUCTURE FOR THE FIRST 10'. THAN 9 SQUARE FEET. A7.8 COMMON DETAILS - TRANSITIONS
2. BOTTOM EDGE OF GLAZING IS LESS THAN 18" ABOVE
GALVANIZED DOWNSPOUTS TO HAVE ADJUSTABLE THE FLOOR. A7.9 COMMON DETAILS - ROOF
EXTENDERS TO CARRY WATER MIN. 5'-0" AWAY FROM 3. TOP EDGE OF THE GLAZING IS MORE THAN 36" ABOVE
BUILDING OR AS RECOMMENDED BY SOILS REPORT (TYP). THE FLOOR. A7.10 COMMON DETAILS - ROOF
4. ONE OR MORE WALKING SURFACES ARE WITHIN 36",
MEASURED HORIZONTALLY AND IN A STRAIGHT LINE
A7.11 COMMON DETAILS - PENETRATIONS
GUARDRAILS -SHALL BE LOCATED ALONG ALL OPEN-SIDED OF THE GLAZING.
WALKING SURFACES INCLUDING STAIRS, RAMPS AND D. ALL GLAZING IN RAILINGS REGARDLESS OF AREA AND
A7.12 COMMON DETAILS - PENETRATIONS
LANDINGS (INCLUDING PATIOS) THAT ARE LOCATED MORE HEIGHT ABOVE A WALKING SURFACE. INCLUDED ARE
THAN 30" HIGH TO ANY POINT WITHIN 36" HORZ. TO THE EDGE STRUCTURAL BALUSTER PANELS AND NONSTRUCTURAL
A7.13 COMMON DETAILS - DECKING
OF THE OPEN SIDE. INFILL PANELS PER R308.4.4.
A. GUARDS SHALL BE NOT LESS THAN 36" HIGH EXCEPTION: E. WITHIN ANY COMPARTMENT CONTAINING HOT TUBS,
WHERE THE TOP OF THE GUARD ALSO SERVES AS A WHIRLPOOLS, SAUNAS, STEAM ROOMS, A7.14 COMMON DETAILS - STAIRS
HANDRAIL ON THE OPEN SIDES OF STAIRS, THE TOP OF BATHTUBS/SHOWERS WHOSE BOTTOM EDGE OF GLAZING
THE GUARD SHALL NOT BE LESS THAN 34" AND NOT IS LESS THAN 60" A.F.F. PER R308.4.5. A7.15 COMMON DETAILS - THERMAL BARRIER
MORE THAN 38" H. F. GLAZING ADJACENT TO STAIRWAYS, LANDINGS AND
B. INTERMEDIATE BALUSTERS/RAILS SHALL BE RAMPS WITHIN 36" HORIZONTALLY OF A WALKING A7.16 COMMON DETAILS - THERMAL BARRIER
CONSTRUCTED SUCH THAT A SPHERE 4" IN DIAMETER SURFACE WHEN THE EXPOSED SURFACE OF THE
CANNOT PASS THROUGH. GLAZING IS LESS THAN 36" ABOVE THE PLANE OF THE
ADJACENT WALKING SURFACE PER R308.4.6.
G. GLAZING ADJACENT TO STAIRWAYS WITHIN 60"
HORIZONTALLY OF THE BOTTOM TREAD OF A STAIRWAY
IN ANY DIRECTION WHEN THE EXPOSED SURFACE OF THE E1.0 LOWER LEVEL ELECTRICAL PLAN
FOUNDATION DESIGN AND SOILS REPORT BY COLORADO
GLAZING IS LESS THAN 36" ABOVE THE NOSE OF THE
REGISTERED ENGINEER AND PER IRC. FOUNDATIONS OPT. FULL LOWER LEVEL ELECTRICAL PLAN
TREAD, PER R308.4.7. E1.1
SHOWN ARE GENERIC. FOUNDATION AND BASEMENT FLOOR
H. GLAZING IN WALLS/FENCES ADJACENT TO
DESIGN MAY REQUIRE FLOATING WALLS - SEE ENGINEER'S
INDOOR/OUTDOOR SWIMMING POOLS, HOT TUBS, SPAS E2.0 MAIN LEVEL ELECTRICAL PLAN
DETAILS. ENGINEER SHALL BE ON HAND AT TIME OF
WHERE THE BOTTOM EDGE OF THE GLAZING IS LESS
INSPECTION.
THAN 60" MEASURED HORIZONTALLY AND IN A STRAIGHT E2.1 MAIN LEVEL ELECTRICAL PLAN OPTIONS
LINE OF THE WATER'S EDGE, PER R308.4.5.
PER ENGINEER AND IRC SECTION 506, PROVIDE A MIN. 4" E3.0 UPPER LEVEL ELECTRICAL PLAN
BASE COURSE OF SAND, GRAVEL, CRUSHED STONE OR
IN BATHROOMS CONTAINING A BATHTUB OR SHOWER OR
CRUSHED BLAST-FURNACE SLAG UNDER CONCRETE FLOORS
COMBINATION THEREOF, WATER CLOSET COMPARTMENTS,
ON GROUND WITH A 6 MIL POLYETHYLENE OR APPROVED
LAUNDRY ROOMS AND SIMILAR ROOMS THAT DO NOT HAVE
VAPOR RETARDER WITH JOINTS LAPPED NOT LESS THAN 6"
ACCESS TO NATURAL VENTILATION, A MECHANICAL
AND PLACED BETWEEN THE BASE COURSE AND THE SLAB.
VENTILATION SYSTEM CONNECTED DIRECTLY TO THE
OUTSIDE IS TO BE PROVIDED PER IRC.

PROVIDE FIREBLOCKING IN COMBUSTIBLE CONSTRUCTION


TO CUT OFF ALL CONCEALED DRAFT OPENINGS (BOTH VERT.
AND HORZ.) AT THE FOLLOWING LOCATIONS: AUTOMATIC FIRE SPRINKLERS:
1. IN WALLS VERTICALLY AT THE CEILING AND FLOOR AN AUTOMATIC FIRE SPRINKLER SYSTEM PER IRC SECTION
LEVELS. P2904 IS REQUIRED TO BE INSTALLED PER TOWN OF
2. IN WALLS HORIZONTALLY AT INTERVALS NOT EXCEEDING JOHNSTOWN LOCAL CODE AMENDMENT.
10 FEET.
3. AT ALL INTERCONNECTIONS BETWEEN CONCEALED SMOKE ALARMS ARE TO BE INSTALLED IN ACCORDANCE WITH
VERTICAL AND HORIZONTAL SPACES. MANUFACTURER'S INSTRUCTIONS, AND THE PROVISIONS OF
4. IN CONCEALED SPACES BETWEEN STAIR STRINGERS AT NFPA 72 (HOUSEHOLD FIRE WARNING EQUIPMENT) AND THE
THE TOP AND BOTTOM OF THE RUN. PROVISIONS PER IRC SECTION R314.4 LINK THE AUDIO
5. AT OPENINGS AROUND VENTS, PIPES, DUCTS, CABLES SIGNAL TO ALL UNITS. ALL SMOKE ALARMS SHALL BE LISTED
AND WIRES AT CEILING AND FLOOR LEVELS. IN ACCORDANCE WITH UL 217.

IN COMBUSTIBLE CONSTRUCTION WHERE THERE IS USABLE CARBON MONOXIDE DETECTORS ARE TO BE INSTALLED IN
SPACE BOTH ABOVE AND BELOW THE CONCEALED SPACE OF ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS, AND
A FLOOR / CEILING ASSEMBLY, DRAFTSTOPS SHALL BE THE PROVISIONS OF NFPA 720 AND THE PROVISIONS PER IRC
INSTALLED SO THAT THE AREA OF THE CONCEALED SPACE SECTION R315.5 LINK AUDIO SYSTEM WITH ALL UNITS. ALL
DOES NOT EXCEED 1,000 S.F.. DRAFTSTOPPING SHALL DIVIDE CARBON MONOXIDE DETECTORS SHALL BE LISTED IN
THE CONCEALED SPACE INTO APPROX. EQUAL AREAS. ACCORDANCE WITH UL 217.
WHERE THE ASSEMBLY IS ENCLOSED BY A FLOOR
MEMBRANE ABOVE AND A CEILING MEMBRANE BELOW,
DRAFTSTOPPING SHALL BE PROVIDED IN FLOOR CEILING
ASSEMBLIES UNDER THE FOLLOWING CIRCUMSTANCES:
1. CEILING IS SUSPENDED UNDER THE FLOOR FRAMING.
2. FLOOR FRAMING IS CONSTRUCTED OF TRUSS TYPE
OPEN WEB OR PERFORATED MEMBERS.

©
LOWER LEVEL NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION


NOT SHOWN OR NOTED ON PLANS
FIRE PROTECTION OF FLOORS: FLOOR ASSEMBLIES LOCATED
DIRECTLY OVER UNFINISHED/STORAGE SPACES, AND CRAWL
SPACES INTENDED FOR STORAGE AND/OR HEATING
APPLIANCES SHALL BE SEPARATED AS REQUIRED PER R302.13.
NOT LESS THAN 1/2" GYPSUM WALLBOARD OR EQUIVALENT
Godden|Sudik
SHALL BE APPLIED TO THE UNFINISHED/STORAGE SIDE ON THE A R C H I T E C T S
UNDERSIDE OF THE FLOOR FRAMING MEMBERS. REFER TO SEE WHAT COULD BE
R302.13 "EXCEPTIONS" 1 TO 4 FOR NON-APPLICABLE LOCATIONS
AND ALTERNATE APPLICATIONS.
ALL NON 90° ANGLES ARE 45° U.N.O.
ALL WALL DIMENSIONS ARE 2x4 (3 1/2") TYP., U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS BY A DOOR
OR ACCESS PANEL SHALL HAVE WALLS, UNDER-STAIR
SURFACE AND ANY SOFFITS PROTECTED ON THE
ENCLOSED SIDE WITH 1/2" GYPSUM BOARD PER R302.7
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPECS
FOUNDATION WALL FURRING:
2x4 (3-1/2") FRAMING SET 2" OFF FOUNDATION WALL (5-1/2" F.O.
FND. TO F.O. FRAME), U.N.O. FOR CONCRETE TOLERANCES

SUMP PUMP:
COLUMN ABV. COLUMN ABV.
BUILDER TO COORDINATE SUMP PIT LOCATION IN FIELD AND
W/ OPT. EXT. W/ OPT. EXT. WITH SOILS REPORT SPEC'S. PER P3007.3 AND P3303.1.
COVERED PATIO COVERED PATIO
FURNACE AND HOT WATER HEATER:
FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
OPT. PATIO ABV. OPT. EXT. COVERED PATIO ABV.
UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24.
49'-0"
THE PRESSURE RELIEF VALVE FOR THE WATER HEATER MUST
DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY A FLOOR
DRAIN, PER M2002.4 AND P2804.
11'-0" 10'-0" 28'-0"
WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN PAN
MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST BE AT
LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER P2801.6.2.
WHEN THE WATER HEATER IS LOCATED ON A CONCRETE SLAB,
AN APPROVED FLOOR DRAIN MUST BE IN THE IMMEDIATE
LOCATION AND THE SLAB MUST HAVE A MINIMUM SLOPE OF 1/4"
CONC. PER FOOT TO THE EMBEDDED FLOOR DRAIN.
STOOP ABV. ROUGH-IN PLUMBING FOR FUTURE BATH:
PROVIDE CAPPED PLUMBING LINES, PER BUILDER SPEC'S.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


PER R408, THE UNDER-FLOOR SPACE BETWEEN THE
BOTTOM OF THE FLOOR JOISTS AND THE EARTH UNDER
ANY BUILDING (EXCEPT BASEMENTS) SHALL BE UNVENTED
AND HAVE THE FOLLOWING UNLESS NOTED OTHERWISE:
1. EXPOSED EARTH IS COVERED WITH A CONTINUOUS
CLASS I VAPOR RETARDER. JOINTS OF THE VAPOR
RETARDER SHALL OVERLAP BY 6 INCHES AND SHALL BE

1'-6"

8"
SEALED OR TAPED. THE EDGES OF THE VAPOR RETARDER

4'-0"

PHONE: 303-770-8300
SHALL EXTEND AT LEAST 6 INCHES UP THE STEM WALL AND
CRAWL SHALL BE ATTACHED AND SEALED TO THE STEM WALL.
2. ONE OF THE FOLLOWING SHALL ALSO BE PROVIDED:

2'-6"
SPACE WINDOW HEAD HEIGHT = 6'-8"

4040 SL
A. CONTINUOUSLY OPERATED MECHANICAL EXHAUST
ACCESS

DR.
AT 7'-8" CEILING VENTILATION AT A RATE EQUAL TO 1 CUBIC FOOT PER
WINDOW HEAD HEIGHT = 7'-0" MINUTE FOR EACH 50 SQUARE FEET OF CRAWLSPACE
AT OPT. 8'-8" CEILING FLOOR AREA, INCLUDING AN AIR PATHWAY TO THE COMMON
AREA, AND PERIMETER WALLS INSULATED IN ACCORDANCE
WITH SECTION N1102.2.11 AND ENERGY REPORT.
B. CONDITIONED AIR SUPPLY SIZED TO DELIVER AT A RATE
CRAWL EQUAL TO 1 CUBIC FOOT PER MINUTE FOR EACH 50 SQUARE

15'-6 1/2"
FEET OF UNDER-FLOOR AREA, INCLUDING A RETURN AIR
SPACE UNFINISHED

16'-0"
PATHWAY TO THE COMMON AREA, AND PERIMETER WALLS
INSULATED IN ACCORDANCE WITH SECTION N1102.2.9

10'-8"
CONDITIONED 78 CLG.

23'-4 1/2"
36" DEEP METAL
W.H. ALL REQUIRED NON-ABSORBENT WALL SURFACES
AREA WELL W/
SHALL BE INSTALLED OVER CEMENT, FIBER-CEMENT OR
LADDER - EGRESS GLASS MAT GYPSUM BACKING PER R702.4.2
DR. REQUIREMENTS
DIRECT VENT, SEALED 13'-0" 7'-10 1/2" 7'-1 1/2" PER IRC BATH COUNTERTOP:
COMBUSTION FURNACE RETURN ON CABINETS. BACKSPLASH AND MIRROR ABOVE PER BUILDER.
AND WATER HEATER
SHALL BE INSTALLED TUB:
PER IRC N1102.4.4 FURNACE 30" X 60" UNIT, WITH TILE SURROUND NOT LESS THAN 6 FT. AFF.
CLEAR

5 1/2"
PROVIDE FIXTURES, U.N.O.
MECH. TRUNK LINE ACCESS
COLUMN R & S:
ABV. - V.I.F.
RE: STRUCT. INDICATES ROD & SHELF IN CLOSETS, "(2) R & S" INDICATES
(1) HIGH ROD AND (1) LOW ROD PLUS SHELF. SHELVES ARE

32'-7 1/2"
12" DEEP, U.N.O.
BEAM ABV. - RE:
STRUCT. BASEMENTS:
BASEMENTS AND EVERY SLEEPING ROOM SHALL HAVE AT

LANDING

LANDING
BEAM POCKET

28'-7 1/2"
LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE

3'-9"
4'-0"

4'-0"
(TYP.)
OPENING. EMERGENCY ESCAPES SHALL HAVE A SILL HEIGHT
37'-0"

OF NOT MORE THAN 44" ABOVE THE FLOOR PER R310.2


3'-6" 3'-9 1/2"
EGRESS WINDOW WELL MUST ALLOW FULL OPERATION OF
WINDOW, HAVE A CLEAR AREA OF 9 SF. MIN. & A MIN.

8'-8"

HANDRAIL
HORIZONTAL PROJECTION AND WIDTH OF 36". IF WINDOW WELL
IS OVER 44" DEEP, A PERMANENT STAIR, OR LADDER MUST BE

5T @ 10" = 4'-2"
PROVIDED WHICH DOES NOT PREVENT OPERATION OF THE
WINDOW OR ENCROACH MORE THAN 6" INTO THE CLEAR AREA,

1'-9 1/2"
PER R310.2 - R310.2.4
45'-0"

45'-0"
6'-3 1/2"
UNEXCAVATED
WALL LEGEND

17'-0"
STAIRS ABV.

14R
UP
2x4 (3 1/2") STUD WALL
CL TYPICAL INTERIOR WALL (U.N.O.)
PROVIDE 1/2" GYP.
FLOOR ABV. BOARD @

2'-10"
ROUGH-IN
UNDERSIDE OF 2x6 (5 1/2") STUD WALL
PLUMB.
STAIRS PER R302.7 TYPICAL EXTERIOR WALL (U.N.O.)
FUTURE BATH

8'-1 1/2"
CL
FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"

8'-4"
SUMP PIT AT FLAT (A/B) HIGH AT BASEMENT FINISH (U.N.O.)

2'-8"

6'-7"
LOT CONDITION.

8'-9 1/2"
LOCATION TO BE RAISED FOUNDATION LEDGE
VERIFIED DEPENDENT - RE: STRUCTURAL PLANS
CL RAISED
SUMP ON SOILS REPORT AND
CRAWL

1'-8"
PLOT PLAN FOUNDATION WALL - RE: STRUCTURAL PLANS
SPACE PIT
ACCESS

REFER TO STRUCTURAL
DRAWINGS FOR ALL FOUNDATION RAISED
AND CONCRETE DESIGNS AND FOUNDATION -
RE: STRUCTURAL 2'-6" 10'-4"
4'-0"

SPECIFICATIONS.

6" OR 8" FOUNDATION 1'-2"


WALL PER STRUCTURAL
ENGINEER

DEPRESS FNDN. -
RE: STRUCT.

12'-4 1/2"
PORCH
ABV. CRAWL
SPACE

12'-0"
CONDITIONED
8'-0"

1
A6.0

2'-4" 16'-4" 2'-4"

21'-0" 14'-0" 14'-0"

49'-0"

LOWER LEVEL FLOOR PLAN - 'A'


1 SCALE: 1/4" = 1'-0"

©
LOWER LEVEL NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION


NOT SHOWN OR NOTED ON PLANS
FIRE PROTECTION OF FLOORS: FLOOR ASSEMBLIES LOCATED
DIRECTLY OVER UNFINISHED/STORAGE SPACES, AND CRAWL
SPACES INTENDED FOR STORAGE AND/OR HEATING
APPLIANCES SHALL BE SEPARATED AS REQUIRED PER R302.13.
NOT LESS THAN 1/2" GYPSUM WALLBOARD OR EQUIVALENT
Godden|Sudik
SHALL BE APPLIED TO THE UNFINISHED/STORAGE SIDE ON THE A R C H I T E C T S
UNDERSIDE OF THE FLOOR FRAMING MEMBERS. REFER TO SEE WHAT COULD BE
R302.13 "EXCEPTIONS" 1 TO 4 FOR NON-APPLICABLE LOCATIONS
AND ALTERNATE APPLICATIONS.
ALL NON 90° ANGLES ARE 45° U.N.O.
ALL WALL DIMENSIONS ARE 2x4 (3 1/2") TYP., U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS BY A DOOR
OR ACCESS PANEL SHALL HAVE WALLS, UNDER-STAIR
SURFACE AND ANY SOFFITS PROTECTED ON THE
ENCLOSED SIDE WITH 1/2" GYPSUM BOARD PER R302.7
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPECS
FOUNDATION WALL FURRING:
2x4 (3-1/2") FRAMING SET 2" OFF FOUNDATION WALL (5-1/2" F.O.
FND. TO F.O. FRAME), U.N.O. FOR CONCRETE TOLERANCES

SUMP PUMP:
COLUMN ABV. COLUMN ABV.
BUILDER TO COORDINATE SUMP PIT LOCATION IN FIELD AND
W/ OPT. EXT. W/ OPT. EXT. WITH SOILS REPORT SPEC'S. PER P3007.3 AND P3303.1.
COVERED PATIO COVERED PATIO
FURNACE AND HOT WATER HEATER:
FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
OPT. PATIO ABV.
UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24.
49'-0"
THE PRESSURE RELIEF VALVE FOR THE WATER HEATER MUST
DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY A FLOOR
DRAIN, PER M2002.4 AND P2804.
11'-0" 10'-0" 28'-0"
WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN PAN
MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST BE AT
LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER P2801.6.2.
WHEN THE WATER HEATER IS LOCATED ON A CONCRETE SLAB,
AN APPROVED FLOOR DRAIN MUST BE IN THE IMMEDIATE
LOCATION AND THE SLAB MUST HAVE A MINIMUM SLOPE OF 1/4"
CONC. PER FOOT TO THE EMBEDDED FLOOR DRAIN.
STOOP ABV. ROUGH-IN PLUMBING FOR FUTURE BATH:
PROVIDE CAPPED PLUMBING LINES, PER BUILDER SPEC'S.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


PER R408, THE UNDER-FLOOR SPACE BETWEEN THE
BOTTOM OF THE FLOOR JOISTS AND THE EARTH UNDER
ANY BUILDING (EXCEPT BASEMENTS) SHALL BE UNVENTED
AND HAVE THE FOLLOWING UNLESS NOTED OTHERWISE:
1. EXPOSED EARTH IS COVERED WITH A CONTINUOUS
CLASS I VAPOR RETARDER. JOINTS OF THE VAPOR

1'-6"
RETARDER SHALL OVERLAP BY 6 INCHES AND SHALL BE

8"
SEALED OR TAPED. THE EDGES OF THE VAPOR RETARDER

4'-0"

PHONE: 303-770-8300
SHALL EXTEND AT LEAST 6 INCHES UP THE STEM WALL AND
SHALL BE ATTACHED AND SEALED TO THE STEM WALL.
CRAWL 2. ONE OF THE FOLLOWING SHALL ALSO BE PROVIDED:

2'-6"
SPACE WINDOW HEAD HEIGHT = 6'-8"

4040 SL
A. CONTINUOUSLY OPERATED MECHANICAL EXHAUST
ACCESS

DR.
AT 7'-8" CEILING VENTILATION AT A RATE EQUAL TO 1 CUBIC FOOT PER
WINDOW HEAD HEIGHT = 7'-0" MINUTE FOR EACH 50 SQUARE FEET OF CRAWLSPACE
AT OPT. 8'-8" CEILING FLOOR AREA, INCLUDING AN AIR PATHWAY TO THE COMMON
AREA, AND PERIMETER WALLS INSULATED IN ACCORDANCE
WITH SECTION N1102.2.11 AND ENERGY REPORT.
B. CONDITIONED AIR SUPPLY SIZED TO DELIVER AT A RATE
CRAWL EQUAL TO 1 CUBIC FOOT PER MINUTE FOR EACH 50 SQUARE

15'-6 1/2"
10'-8"
FEET OF UNDER-FLOOR AREA, INCLUDING A RETURN AIR
SPACE UNFINISHED

16'-0"
36" DEEP METAL PATHWAY TO THE COMMON AREA, AND PERIMETER WALLS
CONDITIONED INSULATED IN ACCORDANCE WITH SECTION N1102.2.9
78 CLG. AREA WELL W/

23'-4 1/2"
LADDER - EGRESS
REQUIREMENTS
PER IRC ALL REQUIRED NON-ABSORBENT WALL SURFACES
W.H. SHALL BE INSTALLED OVER CEMENT, FIBER-CEMENT OR
DR. GLASS MAT GYPSUM BACKING PER R702.4.2
DIRECT VENT, SEALED 13'-0" 7'-10 1/2" 7'-1 1/2" BATH COUNTERTOP:
COMBUSTION FURNACE RETURN ON CABINETS. BACKSPLASH AND MIRROR ABOVE PER BUILDER.
AND WATER HEATER
SHALL BE INSTALLED TUB:
PER IRC N1102.4.4 FURNACE 30" X 60" UNIT, WITH TILE SURROUND NOT LESS THAN 6 FT. AFF.
CLEAR

5 1/2"
PROVIDE FIXTURES, U.N.O.
MECH. TRUNK LINE ACCESS
COLUMN R & S:
ABV. - V.I.F.
RE: STRUCT. INDICATES ROD & SHELF IN CLOSETS, "(2) R & S" INDICATES
(1) HIGH ROD AND (1) LOW ROD PLUS SHELF. SHELVES ARE

32'-7 1/2"
12" DEEP, U.N.O.
BEAM ABV. - RE:
STRUCT. BASEMENTS:

LANDING
BASEMENTS AND EVERY SLEEPING ROOM SHALL HAVE AT

LANDING
BEAM POCKET

4'-0 1/2"

28'-7 1/2"
LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE

3'-9"
(TYP.)
OPENING. EMERGENCY ESCAPES SHALL HAVE A SILL HEIGHT
37'-0"

OF NOT MORE THAN 44" ABOVE THE FLOOR PER R310.2


3'-6" 3'-9 1/2"
EGRESS WINDOW WELL MUST ALLOW FULL OPERATION OF
WINDOW, HAVE A CLEAR AREA OF 9 SF. MIN. & A MIN.

8'-8"

HANDRAIL
HORIZONTAL PROJECTION AND WIDTH OF 36". IF WINDOW WELL
IS OVER 44" DEEP, A PERMANENT STAIR, OR LADDER MUST BE

5T @ 10" = 4'-2"
PROVIDED WHICH DOES NOT PREVENT OPERATION OF THE
WINDOW OR ENCROACH MORE THAN 6" INTO THE CLEAR AREA,

1'-9 1/2"
PER R310.2 - R310.2.4
45'-0"

45'-0"
6'-3 1/2"
UNEXCAVATED
WALL LEGEND

17'-0"
STAIRS ABV.

14R
UP
2x4 (3 1/2") STUD WALL
CL TYPICAL INTERIOR WALL (U.N.O.)
PROVIDE 1/2" GYP.
BOARD @

2'-10"
ROUGH-IN
UNDERSIDE OF 2x6 (5 1/2") STUD WALL
PLUMB.
STAIRS PER R302.7 TYPICAL EXTERIOR WALL (U.N.O.)
FUTURE BATH

8'-1 1/2"
CL
FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"

8'-4"
SUMP PIT AT FLAT (A/B) HIGH AT BASEMENT FINISH (U.N.O.)

2'-8"

6'-7"
LOT CONDITION.
LOCATION TO BE RAISED FOUNDATION LEDGE

8'-9 1/2"
VERIFIED DEPENDENT - RE: STRUCTURAL PLANS
CL RAISED
SUMP ON SOILS REPORT AND
CRAWL

1'-8"
PLOT PLAN FOUNDATION WALL - RE: STRUCTURAL PLANS
SPACE PIT
ACCESS

REFER TO STRUCTURAL
DRAWINGS FOR ALL FOUNDATION RAISED
AND CONCRETE DESIGNS AND FOUNDATION -
RE: STRUCTURAL 2'-6" 10'-4"
4'-0"

SPECIFICATIONS.

6" OR 8" FOUNDATION 1'-2"


WALL PER STRUCTURAL
ENGINEER

DEPRESS FNDN. -
RE: STRUCT.

12'-4 1/2"
PORCH ABV. CRAWL
SPACE

12'-0"
CONDITIONED
8'-0"

2
A6.0

2'-4" 16'-4" 2'-4"

21'-0" 14'-0" 14'-0"

49'-0"

LOWER LEVEL FLOOR PLAN - 'B'


1 SCALE: 1/4" = 1'-0"

©
LOWER LEVEL NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION


NOT SHOWN OR NOTED ON PLANS
FIRE PROTECTION OF FLOORS: FLOOR ASSEMBLIES LOCATED
DIRECTLY OVER UNFINISHED/STORAGE SPACES, AND CRAWL
SPACES INTENDED FOR STORAGE AND/OR HEATING
APPLIANCES SHALL BE SEPARATED AS REQUIRED PER R302.13.
NOT LESS THAN 1/2" GYPSUM WALLBOARD OR EQUIVALENT
Godden|Sudik
SHALL BE APPLIED TO THE UNFINISHED/STORAGE SIDE ON THE A R C H I T E C T S
UNDERSIDE OF THE FLOOR FRAMING MEMBERS. REFER TO SEE WHAT COULD BE
R302.13 "EXCEPTIONS" 1 TO 4 FOR NON-APPLICABLE LOCATIONS
AND ALTERNATE APPLICATIONS.
ALL NON 90° ANGLES ARE 45° U.N.O.
ALL WALL DIMENSIONS ARE 2x4 (3 1/2") TYP., U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS BY A DOOR
OR ACCESS PANEL SHALL HAVE WALLS, UNDER-STAIR
SURFACE AND ANY SOFFITS PROTECTED ON THE
ENCLOSED SIDE WITH 1/2" GYPSUM BOARD PER R302.7
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
COLUMN ABV. AT OPENING PER MANUFACTURER'S SPECS
ENHANCED FOUNDATION WALL FURRING:
ELEVATION W/ 2x4 (3-1/2") FRAMING SET 2" OFF FOUNDATION WALL (5-1/2" F.O.
OPT. EXT. FND. TO F.O. FRAME), U.N.O. FOR CONCRETE TOLERANCES
COVERED PATIO
SUMP PUMP:
COLUMN ABV. COLUMN ABV.
BUILDER TO COORDINATE SUMP PIT LOCATION IN FIELD AND
W/ OPT. EXT. W/ OPT. EXT. WITH SOILS REPORT SPEC'S. PER P3007.3 AND P3303.1.
COVERED PATIO COVERED PATIO
FURNACE AND HOT WATER HEATER:
FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
OPT. PATIO ABV.
UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24.
49'-0"
THE PRESSURE RELIEF VALVE FOR THE WATER HEATER MUST
DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY A FLOOR
DRAIN, PER M2002.4 AND P2804.
11'-0" 10'-0" 28'-0"
WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN PAN
MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST BE AT
LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER P2801.6.2.
WHEN THE WATER HEATER IS LOCATED ON A CONCRETE SLAB,
AN APPROVED FLOOR DRAIN MUST BE IN THE IMMEDIATE
LOCATION AND THE SLAB MUST HAVE A MINIMUM SLOPE OF 1/4"
CONC. PER FOOT TO THE EMBEDDED FLOOR DRAIN.
STOOP ABV. ROUGH-IN PLUMBING FOR FUTURE BATH:
PROVIDE CAPPED PLUMBING LINES, PER BUILDER SPEC'S.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


PER R408, THE UNDER-FLOOR SPACE BETWEEN THE
BOTTOM OF THE FLOOR JOISTS AND THE EARTH UNDER
ANY BUILDING (EXCEPT BASEMENTS) SHALL BE UNVENTED
AND HAVE THE FOLLOWING UNLESS NOTED OTHERWISE:
1. EXPOSED EARTH IS COVERED WITH A CONTINUOUS
CLASS I VAPOR RETARDER. JOINTS OF THE VAPOR

1'-6"
RETARDER SHALL OVERLAP BY 6 INCHES AND SHALL BE

8"
SEALED OR TAPED. THE EDGES OF THE VAPOR RETARDER

4'-0"

PHONE: 303-770-8300
SHALL EXTEND AT LEAST 6 INCHES UP THE STEM WALL AND
SHALL BE ATTACHED AND SEALED TO THE STEM WALL.
CRAWL 2. ONE OF THE FOLLOWING SHALL ALSO BE PROVIDED:

2'-6"
SPACE WINDOW HEAD HEIGHT = 6'-8"

4040 SL
A. CONTINUOUSLY OPERATED MECHANICAL EXHAUST
ACCESS AT 7'-8" CEILING

DR.
VENTILATION AT A RATE EQUAL TO 1 CUBIC FOOT PER
WINDOW HEAD HEIGHT = 7'-0" MINUTE FOR EACH 50 SQUARE FEET OF CRAWLSPACE
AT OPT. 8'-8" CEILING FLOOR AREA, INCLUDING AN AIR PATHWAY TO THE COMMON
AREA, AND PERIMETER WALLS INSULATED IN ACCORDANCE
WITH SECTION N1102.2.11 AND ENERGY REPORT.
B. CONDITIONED AIR SUPPLY SIZED TO DELIVER AT A RATE
CRAWL EQUAL TO 1 CUBIC FOOT PER MINUTE FOR EACH 50 SQUARE

15'-6 1/2"
10'-8"
FEET OF UNDER-FLOOR AREA, INCLUDING A RETURN AIR
SPACE UNFINISHED

16'-0"
36" DEEP METAL PATHWAY TO THE COMMON AREA, AND PERIMETER WALLS
CONDITIONED INSULATED IN ACCORDANCE WITH SECTION N1102.2.9
78 CLG. AREA WELL W/

23'-4 1/2"
LADDER - EGRESS
REQUIREMENTS
PER IRC ALL REQUIRED NON-ABSORBENT WALL SURFACES
W.H. SHALL BE INSTALLED OVER CEMENT, FIBER-CEMENT OR
DR. GLASS MAT GYPSUM BACKING PER R702.4.2
DIRECT VENT, SEALED 13'-0" 7'-10 1/2" 7'-1 1/2" BATH COUNTERTOP:
COMBUSTION FURNACE RETURN ON CABINETS. BACKSPLASH AND MIRROR ABOVE PER BUILDER.
AND WATER HEATER
SHALL BE INSTALLED TUB:
CRAWL
FURNACE 30" X 60" UNIT, WITH TILE SURROUND NOT LESS THAN 6 FT. AFF.
PER IRC N1102.4.4 CLEAR
SPACE

5 1/2"
PROVIDE FIXTURES, U.N.O.
MECH. TRUNK LINE ACCESS ACCESS
COLUMN R & S:
ABV. - V.I.F.
RE: STRUCT. INDICATES ROD & SHELF IN CLOSETS, "(2) R & S" INDICATES
(1) HIGH ROD AND (1) LOW ROD PLUS SHELF. SHELVES ARE

32'-7 1/2"
12" DEEP, U.N.O.
BEAM ABV. - RE:
STRUCT. BASEMENTS:

LANDING
BASEMENTS AND EVERY SLEEPING ROOM SHALL HAVE AT

LANDING
BEAM POCKET

4'-0 1/2"

28'-7 1/2"
LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE

3'-9"
(TYP.)
OPENING. EMERGENCY ESCAPES SHALL HAVE A SILL HEIGHT
37'-0"

OF NOT MORE THAN 44" ABOVE THE FLOOR PER R310.2


3'-6" 3'-9 1/2"
EGRESS WINDOW WELL MUST ALLOW FULL OPERATION OF
WINDOW, HAVE A CLEAR AREA OF 9 SF. MIN. & A MIN.

8'-8"

HANDRAIL
HORIZONTAL PROJECTION AND WIDTH OF 36". IF WINDOW WELL
IS OVER 44" DEEP, A PERMANENT STAIR, OR LADDER MUST BE

5T @ 10" = 4'-2"
PROVIDED WHICH DOES NOT PREVENT OPERATION OF THE
WINDOW OR ENCROACH MORE THAN 6" INTO THE CLEAR AREA,

1'-9 1/2"
PER R310.2 - R310.2.4
45'-0"

45'-0"
6'-3 1/2"
UNEXCAVATED
WALL LEGEND

17'-0"
STAIRS ABV.

14R
UP
2x4 (3 1/2") STUD WALL
CL TYPICAL INTERIOR WALL (U.N.O.)
PROVIDE 1/2" GYP.
BOARD @

2'-10"
ROUGH-IN
UNDERSIDE OF 2x6 (5 1/2") STUD WALL
PLUMB.
STAIRS PER R302.7 TYPICAL EXTERIOR WALL (U.N.O.)
FUTURE BATH

8'-1 1/2"
CL
FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"

8'-4"
SUMP PIT AT FLAT (A/B) HIGH AT BASEMENT FINISH (U.N.O.)

2'-8"

6'-7"
LOT CONDITION.
LOCATION TO BE RAISED FOUNDATION LEDGE

8'-9 1/2"
VERIFIED DEPENDENT - RE: STRUCTURAL PLANS
CL RAISED
SUMP ON SOILS REPORT AND
CRAWL

1'-8"
PLOT PLAN FOUNDATION WALL - RE: STRUCTURAL PLANS
SPACE PIT
ACCESS

REFER TO STRUCTURAL
DRAWINGS FOR ALL FOUNDATION RAISED
AND CONCRETE DESIGNS AND FOUNDATION -
RE: STRUCTURAL 2'-6" 10'-4"
4'-0"

SPECIFICATIONS.

6" OR 8" FOUNDATION 1'-2"


WALL PER STRUCTURAL
ENGINEER

DEPRESS FNDN. -
RE: STRUCT.

12'-4 1/2"
PORCH ABV. CRAWL
SPACE

12'-0"
CONDITIONED
8'-0"

3
A6.0

2'-4" 16'-4" 2'-4"

21'-0" 14'-0" 14'-0"

49'-0"

LOWER LEVEL FLOOR PLAN - 'C'


1 SCALE: 1/4" = 1'-0"

©
LOWER LEVEL NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION


NOT SHOWN OR NOTED ON PLANS
FIRE PROTECTION OF FLOORS: FLOOR ASSEMBLIES LOCATED
DIRECTLY OVER UNFINISHED/STORAGE SPACES, AND CRAWL
SPACES INTENDED FOR STORAGE AND/OR HEATING
APPLIANCES SHALL BE SEPARATED AS REQUIRED PER R302.13.
NOT LESS THAN 1/2" GYPSUM WALLBOARD OR EQUIVALENT
Godden|Sudik
SHALL BE APPLIED TO THE UNFINISHED/STORAGE SIDE ON THE A R C H I T E C T S
UNDERSIDE OF THE FLOOR FRAMING MEMBERS. REFER TO SEE WHAT COULD BE
R302.13 "EXCEPTIONS" 1 TO 4 FOR NON-APPLICABLE LOCATIONS
AND ALTERNATE APPLICATIONS.
ALL NON 90° ANGLES ARE 45° U.N.O.
ALL WALL DIMENSIONS ARE 2x4 (3 1/2") TYP., U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
ENCLOSED ACCESSIBLE SPACE UNDER STAIRS BY A DOOR
OR ACCESS PANEL SHALL HAVE WALLS, UNDER-STAIR
SURFACE AND ANY SOFFITS PROTECTED ON THE
ENCLOSED SIDE WITH 1/2" GYPSUM BOARD PER R302.7
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPECS
FOUNDATION WALL FURRING:
2x4 (3-1/2") FRAMING SET 2" OFF FOUNDATION WALL (5-1/2" F.O.
FND. TO F.O. FRAME), U.N.O. FOR CONCRETE TOLERANCES

SUMP PUMP:
COLUMN ABV. COLUMN ABV.
BUILDER TO COORDINATE SUMP PIT LOCATION IN FIELD AND
W/ OPT. EXT. W/ OPT. EXT. WITH SOILS REPORT SPEC'S. PER P3007.3 AND P3303.1.
COVERED PATIO COVERED PATIO
FURNACE AND HOT WATER HEATER:
FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
OPT. PATIO ABV.
UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24.
49'-0"
THE PRESSURE RELIEF VALVE FOR THE WATER HEATER MUST
DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY A FLOOR
30'-5 1/2" DRAIN, PER M2002.4 AND P2804.
11'-0" 7'-6 1/2"
WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN PAN
MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST BE AT
LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER P2801.6.2.
WHEN THE WATER HEATER IS LOCATED ON A CONCRETE SLAB,
AN APPROVED FLOOR DRAIN MUST BE IN THE IMMEDIATE
LOCATION AND THE SLAB MUST HAVE A MINIMUM SLOPE OF 1/4"
CONC. PER FOOT TO THE EMBEDDED FLOOR DRAIN.
36" DEEP METAL STOOP ABV. ROUGH-IN PLUMBING FOR FUTURE BATH:
AREA WELL W/ PROVIDE CAPPED PLUMBING LINES, PER BUILDER SPEC'S.
LADDER - EGRESS

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


REQUIREMENTS
DR. PER IRC PER R408, THE UNDER-FLOOR SPACE BETWEEN THE
BOTTOM OF THE FLOOR JOISTS AND THE EARTH UNDER
ANY BUILDING (EXCEPT BASEMENTS) SHALL BE UNVENTED
4040 SL AND HAVE THE FOLLOWING UNLESS NOTED OTHERWISE:
1. EXPOSED EARTH IS COVERED WITH A CONTINUOUS
CLASS I VAPOR RETARDER. JOINTS OF THE VAPOR
RETARDER SHALL OVERLAP BY 6 INCHES AND SHALL BE
SEALED OR TAPED. THE EDGES OF THE VAPOR RETARDER

4'-0"

PHONE: 303-770-8300
SHALL EXTEND AT LEAST 6 INCHES UP THE STEM WALL AND
SHALL BE ATTACHED AND SEALED TO THE STEM WALL.
2. ONE OF THE FOLLOWING SHALL ALSO BE PROVIDED:
WINDOW HEAD HEIGHT = 6'-8"

4040 SL
A. CONTINUOUSLY OPERATED MECHANICAL EXHAUST
AT 7'-8" CEILING

DR.
VENTILATION AT A RATE EQUAL TO 1 CUBIC FOOT PER
WINDOW HEAD HEIGHT = 7'-0" MINUTE FOR EACH 50 SQUARE FEET OF CRAWLSPACE
AT OPT. 8'-8" CEILING FLOOR AREA, INCLUDING AN AIR PATHWAY TO THE COMMON
AREA, AND PERIMETER WALLS INSULATED IN ACCORDANCE
WITH SECTION N1102.2.11 AND ENERGY REPORT.
B. CONDITIONED AIR SUPPLY SIZED TO DELIVER AT A RATE
EQUAL TO 1 CUBIC FOOT PER MINUTE FOR EACH 50 SQUARE

15'-6 1/2"
FEET OF UNDER-FLOOR AREA, INCLUDING A RETURN AIR
UNFINISHED

16'-0"
PATHWAY TO THE COMMON AREA, AND PERIMETER WALLS
INSULATED IN ACCORDANCE WITH SECTION N1102.2.9
88 CLG.

23'-4 1/2"
W.H. ALL REQUIRED NON-ABSORBENT WALL SURFACES
SHALL BE INSTALLED OVER CEMENT, FIBER-CEMENT OR
DR. GLASS MAT GYPSUM BACKING PER R702.4.2

9'-4" 13'-0" MECH. TRUNK LINE 7'-10 1/2" 7'-1 1/2" BATH COUNTERTOP:
RETURN ABV. - V.I.F. ON CABINETS. BACKSPLASH AND MIRROR ABOVE PER BUILDER.
DIRECT VENT, SEALED
COMBUSTION FURNACE TUB:
AND WATER HEATER FURNACE 30" X 60" UNIT, WITH TILE SURROUND NOT LESS THAN 6 FT. AFF.
CLEAR

5 1/2"
SHALL BE INSTALLED PROVIDE FIXTURES, U.N.O.
ACCESS
PER IRC N1102.4.4 COLUMN R & S:
RE: STRUCT. INDICATES ROD & SHELF IN CLOSETS, "(2) R & S" INDICATES
(1) HIGH ROD AND (1) LOW ROD PLUS SHELF. SHELVES ARE
12" DEEP, U.N.O.
BEAM ABV. - RE:
STRUCT. BASEMENTS:
BASEMENTS AND EVERY SLEEPING ROOM SHALL HAVE AT

LANDING
BEAM POCKET
LEAST ONE OPERABLE EMERGENCY ESCAPE AND RESCUE

3'-9"
4'-0"

4'-0"
(TYP.)
OPENING. EMERGENCY ESCAPES SHALL HAVE A SILL HEIGHT
37'-0"

OF NOT MORE THAN 44" ABOVE THE FLOOR PER R310.2


3'-6" 3'-9 1/2"
EGRESS WINDOW WELL MUST ALLOW FULL OPERATION OF
WINDOW, HAVE A CLEAR AREA OF 9 SF. MIN. & A MIN.

HANDRAIL
HORIZONTAL PROJECTION AND WIDTH OF 36". IF WINDOW WELL
IS OVER 44" DEEP, A PERMANENT STAIR, OR LADDER MUST BE

10'-4"
PROVIDED WHICH DOES NOT PREVENT OPERATION OF THE

7T @ 10" = 5'-10"
WINDOW OR ENCROACH MORE THAN 6" INTO THE CLEAR AREA,

1'-9 1/2"
PER R310.2 - R310.2.4
45'-0"

45'-0"
6'-3 1/2"
UNEXCAVATED
WALL LEGEND

41'-0"
17'-0"
STAIRS ABV.
2x4 (3 1/2") STUD WALL
CL TYPICAL INTERIOR WALL (U.N.O.)
PROVIDE 1/2" GYP.
BOARD @

2'-10"
ROUGH-IN

16R
UP
UNDERSIDE OF 2x6 (5 1/2") STUD WALL
PLUMB.
STAIRS PER R302.7 TYPICAL EXTERIOR WALL (U.N.O.)
FUTURE BATH
CL
FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"

6'-5 1/2"
HIGH AT BASEMENT FINISH (U.N.O.)

2'-8"

6'-8"

7'-1 1/2"
RAISED FOUNDATION LEDGE
- RE: STRUCTURAL PLANS
CL RAISED

1'-8"
FOUNDATION WALL - RE: STRUCTURAL PLANS

REFER TO STRUCTURAL
DRAWINGS FOR ALL FOUNDATION RAISED
AND CONCRETE DESIGNS AND FOUNDATION -

18'-11 1/2"
RE: STRUCTURAL
4'-0"

SPECIFICATIONS.

6" OR 8" FOUNDATION


WALL PER STRUCTURAL
ENGINEER

DEPRESS FNDN. -
RE: STRUCT. PORCH
ABV.

12'-0"
SUMP PIT AT FLAT (A/B)
8'-0"

LOT CONDITION.
LOCATION TO BE
VERIFIED DEPENDENT
1 ON SOILS REPORT AND
SUMP
A6.0 PLOT PLAN
PIT

2'-4" 16'-4" 2'-4"

21'-0" 14'-0" 14'-0"

49'-0"

OPT. FULL LOWER LEVEL FLOOR PLAN - 'A'


1 ELEVATIONS 'B' & 'C' SIMILAR SCALE: 1/4" = 1'-0"

©
MAIN / UPPER PLAN NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT SHOWN OR NOTED ON PLANS
ALL NON 90° ANGLES ARE 45°, U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
Godden|Sudik
TYPICAL GUARDRAIL MIN. 36" ABOVE THE ADJACENT
A R C H I T E C T S
FINISHED FLOOR AND SHALL NOT HAVE OPENINGS WHICH SEE WHAT COULD BE
ALLOW THE PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPEC'S.

COUNTERTOP:
36" H. ON BASE CABINETS, BACKSPLASH PER BUILDER.
UPPER WALL CABINETS:
12" D. CABINETS INDICATED BY DASHED LINE ON PLAN,
TYP. CABINET HEIGHTS WILL VARY PER BUILDER, U.N.O.
SINK:
PROVIDE DISPOSAL, SWITCH POWER. RE: ELECT. PLANS.
REFRIGERATOR:
COORDINATE PLUMBING FOR WATER LINE AS REQUIRED.

FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT


GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM SHALL
BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS PER R702.4.2.
BATHTUB AND SHOWER FLOORS AND WALLS ABOVE
49'-0" BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL
11'-0" 38'-0" EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE
THE FLOOR PER R307.2.
COUNTERTOP:
9'-0 1/2" 13'-9" 7'-10 1/2" 7'-4" 30" H. ON BASE CABINETS (U.N.O.), BACKSPLASH AND
MIRROR ABOVE PER BUILDER.
A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
OPT. PATIO OPT. EXT. CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE
COVERED PATIO WALL, PARTITION, VANITY OR CLOSER THAN 30 INCHES
CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE
SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES IN
COLUMN AT COLUMN AT FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO ANY
OPT. EXT. COVERED OPT. EXT. COVERED WALL, FIXTURE OR DOOR PER R307.1, P2705.1.
PATIO PATIO

CLOTHES WASHER/DRYER LOCATION:

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SIDE-BY-SIDE WASHER/DRYER PLUMBING, ELECTRICAL,
36" x 36" CONC. AND EXHAUST SHALL BE CONFIGURED TO ALLOW FOR THE
STOOP W/ STEPS WASHER TO BE INSTALLED AND ORIENTED ON THE LEFT
PER GRADE SIDE WHEN FACING THE APPLIANCES.
SHELVING OR CABINETRY PER PLAN AND BUILDER SPEC'S.
LAUNDRY SINK PER PLAN AND BUILDER SPEC'S.
DRYER VENT:
HB INSTALL A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE
5050 SL

PHONE: 303-770-8300
5050 SL 6080 SGD (T) STEP EXTERIOR. VENT MUST BE EQUIPPED WITH A BACKDRAFT
DAMPER PER G2439.3. THE MAXIMUM LENGTH OF THE
EXHAUST DUCT SHALL BE 35' FROM THE CONNECTION TO
THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET

3'-10 1/2"
TERMINAL. WHERE FITTINGS ARE USED, THE MAX. LENGTH
OF THE EXHAUST DUCT SHALL BE REDUCED IN
5 1/2" ACCORDANCE WITH TABLE G2439.7.4.1.
8'-5 1/2"
CLOTHES WASHER PAN AND FLOOR DRAIN:
FLOOR DRAIN INSTALLATION AND LOCATION TO COMPLY
30" COOKTOP WITH P2719.1.
PROVIDED AT
BUILDER TO FIELD VERIFY FLOOR DRAIN LOCATION WITH

DW
OPT. GOURMET
FLOOR FRAMING LAYOUT. ADJUST FRAMING AS REQUIRED

30" SLIDE-IN

MICRO ABV.
KITCHEN W/

RANGE w/
PRIOR TO FLOOR DRAIN INSTALLATION.

36" H. ISLAND
VENTED MICRO
PROVIDE AN APPROVED PAN UNDER WASHER AND
GREAT ABV.

6'-4"

DBL SNK
COORDINATE FLOOR DRAIN LOCATION WITH THE PAN

FIREPLACE
ROOM DINING "TYPE" PER BUILDER SPEC'S.

16'-0"

OPT.
90 CLG. 90 CLG. KITCHEN LOCATE WASHER GRAY BOX AS REQUIRED PER CODE.

90 CLG. STACKED CLOTHES WASHER/DRYER UNITS:


ACCESS, PLUMBING, ELECTRICAL AND EXHAUST, SIMILAR IN
APPLICATION AND CODE COMPLIANCE.

17'-6 1/2"
21'-8"

19'-10"
34 1/2" H. 2 x 6
3 1/2" 7" KNEE WALL BLW. FURNACE AND HOT WATER HEATER:
FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
11'-0" 10'-2" 4'-6" 3'-0" 4'-9" 7'-7" 7'-1 1/2" UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.

OPT. 36" REF


PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24

5'-9 1/2"
DBL. OVEN
PROVIDED AT THE PRESSURE RELIEF VALVE FOR THE WATER HEATER
MUST DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY

5 1/2"
OPT. GOURMET
MECH. KITCHEN A FLOOR DRAIN, PER M2002.4 AND P2804.
CHASE WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN
PAN MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST
BE AT LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER

LANDING
STEP

9 1/2"
P2801.6.2.

2040 FX
4'-0"
2'-11 1/2"

3'-6"
4'-8"

3'-9"
1'-10 1/2"

4'-0"
CL

28

68

2'-3 1/2"
37'-0"

68

SHELVES
R & S:

26
UP

(4) 16"

6'-8 1/2"
PR
3'-6" 3'-9 1/2" INDICATES ROD & SHELF IN CLOSETS, "(2) R & S"
INDICATES (1) HIGH ROD AND (1) LOW ROD PLUS SHELF.
SHELVES ARE 12" DEEP, U.N.O.
@ ENH. ELEV.

3'-1 1/2"

2468
FIREPLACE:

(4) 16" SH
36" H. KNEE WALL w/ CAP
GAS FIREPLACE (PER BUILDER) W/ DIRECT VENT OR B-VENT
4020 FX

7 T @ 10" = 5'-10"
PANTRY

16R AT OPT. FULL


PER PLANS. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

4'-9 1/2"
STEPS PER GRADE

- OPT. OPEN RAIL

5" LOWER LEVEL


(ALTERNATE STAIRS REFER TO INTERIOR ELEVATIONS FOR DIMENSIONS AND
45'-0"

45'-0"
3-BAY

HANDRAIL
90 CLG.

5'-11 1/2"
DESIGN LAYOUT. MANUFACTURER'S INSTALLATION

6'-10"
AS REQ.)

8'-4"

14R /
GARAGE MUD INSTRUCTIONS FOR ALL FIREPLACES MUST BE KEPT ON SITE
FOR VERIFICATION AND INSPECTION OF REQUIRED
(4) 16" SH
CONC. ROOM CLEARANCES TO COMBUSTIBLE MATERIAL. ALL FIREPLACES

3'-6"
TO BE UL LISTED & PROVIDED WITH A READY ACCESSIBLE
90 CLG.

5 1/2"
SHUT-OFF VALVE PER THE (IFGC) INTERNATIONAL FUEL GAS
5'-6" 2'-0" CODE SEC. 409.5.
ATTIC ACCESS:

DN

4'-2"
THE ROUGHED-FRAMED OPENING SHALL NOT BE LESS

16R
UP

5 1/2"

6'-1 1/2"
THAN 22"x30" AND SHALL BE LOCATED IN A HALLWAY OR
P.R.

68
3'-11 1/2"
4'-1 1/2"
FLOOR OTHER READILY ACCESSIBLE LOCATION PER R807.1.

28
FOYER

4'-3"
ABV. 90 CLG.

2040 SH
APPLIANCES IN ATTIC REQUIREMENTS PER M1305.1.2.
90 CLG. AIR BARRIER SEAL AND INSULATION PER N1102.2.4.

4068 BP

5 1/2"
R&S
15'-4"

6'-9 1/2"

1'-11 1/2"
2468

6'-4"
TO DRAIN
SLOPE

3080
DWELLING-GARAGE OPENING AND PENETRATION
PROTECTION, SHALL COMPLY WITH, SECTION R302.5.
2'-2" 5'-4" 6'-9 1/2" 5'-6 1/2" 7'-1 1/2" - DWELLING-GARAGE FIRE SEPARATION, SHALL COMPLY

2'-8 1/2"
FLOOR ABV. (TYP.), 22 x 30 REMOVE 2040 SH WITH, TABLE R302.6. THIS PROVISION SHALL NOT APPLY TO
ADD 5/8" GYP. BOARD 3 1/2" 7" ATTIC WINDOW AT BATH 3 / GARAGE WALLS THAT ARE PERPENDICULAR TO THE
TO GARAGE CEILING ACCESS OPT. BEDROOM 5 ADJACENT DWELLING UNIT WALL PER R302.6.
PER R302.6 - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
STEP
APPLIED TO THE GARAGE SIDE FROM THE RESIDENCE AND
2040 SH

TO DRAIN
FNDN. CURB ATTICS.

SLOPE
RE: STRUCT. - NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIV.
4'-0"

COV. SHALL BE APPLIED TO THE GARAGE CEILING ADJACENT TO

OFFICE - RE: DETAIL


HABITABLE ROOMS ABOVE THE GARAGE.
PORCH

DOUBLE HOME
OPT. SINGLE /
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE STRUCTURE(S) SUPPORTING FLOOR AND
16080 GD CONC.
3'-8" 7'-6" 2'-10" CEILING ASSEMBLIES.
STUDY

14'-3"

14'-3"
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. APPLIED
2'-0"

HB
90 CLG. TO THE INTERIOR SIDE OF THE EXTERIOR WALL OF A
GARAGE LOCATED LESS THAN 3'-0" FROM A DWELLING UNIT
ON THE SAME LOT.
COLUMN ALL DOORS LEADING INTO GARAGES FROM LIVING SPACES
TO BE MINIMUM TIGHT FITTING, WEATHER-STRIPPED,

12'-0"
RE: DETAIL
20-MINUTE FIRE-RATED, OR 1 3/8" THICK SOLID WOOD, OR
8'-0"

STEPS PER
SOFFIT ABV. 1 3/8" THICK SOLID OR HONEYCOMB CORE STEEL DOORS
GRADE
(TYP.) EQUIPPED WITH SELF-CLOSING OR AUTOMATIC-CLOSING
DEVICE PER R302.5.1.
HOSE BIB:
ALL HOSE BIBBS ARE "FROSTPROOF" TYPE PER R2903.10.
HOSE BIBB BLEED PER P2903.8.5.

WALL LEGEND
5050 SL
2x4 (3 1/2") STUD WALL
1 TYPICAL INTERIOR WALL (U.N.O)
A6.0
2x6 (5 1/2") STUD WALL
TYPICAL EXTERIOR WALL (U.N.O.)

FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"


HIGH AT MAIN AND UPPER LEVEL (U.N.O)
10'-6" 10'-6" 7'-0" 7'-0" 7'-0" 7'-0"

21'-0" 14'-0" 14'-0"

49'-0"

MAIN LEVEL FLOOR PLAN - 'A'


1 SCALE: 1/4" = 1'-0"
©
MAIN / UPPER PLAN NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT SHOWN OR NOTED ON PLANS
ALL NON 90° ANGLES ARE 45°, U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
Godden|Sudik
TYPICAL GUARDRAIL MIN. 36" ABOVE THE ADJACENT
A R C H I T E C T S
FINISHED FLOOR AND SHALL NOT HAVE OPENINGS WHICH SEE WHAT COULD BE
ALLOW THE PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPEC'S.

COUNTERTOP:
36" H. ON BASE CABINETS, BACKSPLASH PER BUILDER.
UPPER WALL CABINETS:
12" D. CABINETS INDICATED BY DASHED LINE ON PLAN,
TYP. CABINET HEIGHTS WILL VARY PER BUILDER, U.N.O.
SINK:
PROVIDE DISPOSAL, SWITCH POWER. RE: ELECT. PLANS.
REFRIGERATOR:
COORDINATE PLUMBING FOR WATER LINE AS REQUIRED.

FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT


GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM SHALL
BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS PER R702.4.2.
BATHTUB AND SHOWER FLOORS AND WALLS ABOVE
49'-0" BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL
11'-0" 38'-0" EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE
THE FLOOR PER R307.2.
COUNTERTOP:
9'-0 1/2" 13'-9" 7'-10 1/2" 7'-4" 30" H. ON BASE CABINETS (U.N.O.), BACKSPLASH AND
MIRROR ABOVE PER BUILDER.
A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
OPT. PATIO OPT. EXT. CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE
COVERED PATIO WALL, PARTITION, VANITY OR CLOSER THAN 30 INCHES
CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE
SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES IN
COLUMN AT COLUMN AT FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO ANY
OPT. EXT. COVERED OPT. EXT. COVERED WALL, FIXTURE OR DOOR PER R307.1, P2705.1.
PATIO PATIO

CLOTHES WASHER/DRYER LOCATION:

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SIDE-BY-SIDE WASHER/DRYER PLUMBING, ELECTRICAL,
36" x 36" CONC. AND EXHAUST SHALL BE CONFIGURED TO ALLOW FOR THE
STOOP W/ STEPS WASHER TO BE INSTALLED AND ORIENTED ON THE LEFT
PER GRADE SIDE WHEN FACING THE APPLIANCES.
SHELVING OR CABINETRY PER PLAN AND BUILDER SPEC'S.
LAUNDRY SINK PER PLAN AND BUILDER SPEC'S.
DRYER VENT:
HB INSTALL A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE
5050 SL

PHONE: 303-770-8300
5050 SL 6080 SGD (T) STEP EXTERIOR. VENT MUST BE EQUIPPED WITH A BACKDRAFT
DAMPER PER G2439.3. THE MAXIMUM LENGTH OF THE
EXHAUST DUCT SHALL BE 35' FROM THE CONNECTION TO
THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET

3'-10 1/2"
TERMINAL. WHERE FITTINGS ARE USED, THE MAX. LENGTH
OF THE EXHAUST DUCT SHALL BE REDUCED IN
5 1/2" ACCORDANCE WITH TABLE G2439.7.4.1.
8'-5 1/2"
CLOTHES WASHER PAN AND FLOOR DRAIN:
FLOOR DRAIN INSTALLATION AND LOCATION TO COMPLY
30" COOKTOP WITH P2719.1.
PROVIDED AT
BUILDER TO FIELD VERIFY FLOOR DRAIN LOCATION WITH

DW
OPT. GOURMET
FLOOR FRAMING LAYOUT. ADJUST FRAMING AS REQUIRED

30" SLIDE-IN

MICRO ABV.
KITCHEN W/

RANGE w/
PRIOR TO FLOOR DRAIN INSTALLATION.

36" H. ISLAND
VENTED MICRO
PROVIDE AN APPROVED PAN UNDER WASHER AND
GREAT ABV.

6'-4"

DBL SNK
COORDINATE FLOOR DRAIN LOCATION WITH THE PAN

FIREPLACE
ROOM DINING "TYPE" PER BUILDER SPEC'S.

16'-0"

OPT.
90 CLG. 90 CLG. KITCHEN LOCATE WASHER GRAY BOX AS REQUIRED PER CODE.

90 CLG. STACKED CLOTHES WASHER/DRYER UNITS:


ACCESS, PLUMBING, ELECTRICAL AND EXHAUST, SIMILAR IN
APPLICATION AND CODE COMPLIANCE.

17'-6 1/2"
21'-8"

19'-10"
34 1/2" H. 2 x 6
3 1/2" 7" KNEE WALL BLW. FURNACE AND HOT WATER HEATER:
FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
11'-0" 10'-2" 4'-6" 3'-0" 4'-9" 7'-7" 7'-1 1/2" UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.

OPT. 36" REF


PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24

5'-9 1/2"
DBL. OVEN
PROVIDED AT THE PRESSURE RELIEF VALVE FOR THE WATER HEATER
MUST DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY

5 1/2"
OPT. GOURMET
MECH. KITCHEN A FLOOR DRAIN, PER M2002.4 AND P2804.
CHASE WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN
PAN MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST
BE AT LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER

LANDING
STEP

9 1/2"
P2801.6.2.

2040 FX
4'-0"
2'-11 1/2"

3'-6"
4'-8"

3'-9"
1'-10 1/2"

4'-0"
CL

28

68

2'-3 1/2"
37'-0"

68

SHELVES
R & S:

26
UP

(4) 16"

6'-8 1/2"
PR
3'-6" 3'-9 1/2" INDICATES ROD & SHELF IN CLOSETS, "(2) R & S"
INDICATES (1) HIGH ROD AND (1) LOW ROD PLUS SHELF.
SHELVES ARE 12" DEEP, U.N.O.
@ ENH. ELEV.

3'-1 1/2"

2468
FIREPLACE:

(4) 16" SH
36" H. KNEE WALL w/ CAP
GAS FIREPLACE (PER BUILDER) W/ DIRECT VENT OR B-VENT
4020 FX

7 T @ 10" = 5'-10"
PANTRY

16R AT OPT. FULL


PER PLANS. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

4'-9 1/2"
STEPS PER GRADE

- OPT. OPEN RAIL

5" LOWER LEVEL


(ALTERNATE STAIRS REFER TO INTERIOR ELEVATIONS FOR DIMENSIONS AND
45'-0"

45'-0"
3-BAY

HANDRAIL
90 CLG.

5'-11 1/2"
DESIGN LAYOUT. MANUFACTURER'S INSTALLATION

6'-10"
AS REQ.)

8'-4"

14R /
GARAGE MUD INSTRUCTIONS FOR ALL FIREPLACES MUST BE KEPT ON SITE
FOR VERIFICATION AND INSPECTION OF REQUIRED
(4) 16" SH
CONC. ROOM CLEARANCES TO COMBUSTIBLE MATERIAL. ALL FIREPLACES

3'-6"
TO BE UL LISTED & PROVIDED WITH A READY ACCESSIBLE
90 CLG.

5 1/2"
SHUT-OFF VALVE PER THE (IFGC) INTERNATIONAL FUEL GAS
5'-6" 2'-0" CODE SEC. 409.5.
ATTIC ACCESS:

DN

4'-2"
THE ROUGHED-FRAMED OPENING SHALL NOT BE LESS

16R
UP

5 1/2"

6'-1 1/2"
THAN 22"x30" AND SHALL BE LOCATED IN A HALLWAY OR
P.R.

68
3'-11 1/2"
4'-1 1/2"
FLOOR OTHER READILY ACCESSIBLE LOCATION PER R807.1.

28
FOYER

4'-3"
ABV. 90 CLG.

2040 SH
APPLIANCES IN ATTIC REQUIREMENTS PER M1305.1.2.
90 CLG. AIR BARRIER SEAL AND INSULATION PER N1102.2.4.

4068 BP

5 1/2"
R&S
15'-4"

6'-9 1/2"

1'-11 1/2"
2468

6'-4"
TO DRAIN
SLOPE

3080
DWELLING-GARAGE OPENING AND PENETRATION
PROTECTION, SHALL COMPLY WITH, SECTION R302.5.
2'-2" 5'-4" 6'-9 1/2" 5'-6 1/2" 7'-1 1/2" - DWELLING-GARAGE FIRE SEPARATION, SHALL COMPLY

2'-8 1/2"
FLOOR ABV. (TYP.), WITH, TABLE R302.6. THIS PROVISION SHALL NOT APPLY TO
ADD 5/8" GYP. BOARD 3 1/2" 7" GARAGE WALLS THAT ARE PERPENDICULAR TO THE
TO GARAGE CEILING ADJACENT DWELLING UNIT WALL PER R302.6.
PER R302.6 CL - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
STEP
APPLIED TO THE GARAGE SIDE FROM THE RESIDENCE AND
IF GYP. BOARD IS 2040 SH
FNDN. CURB ATTICS.
APPLIED, PROVIDE
RE: STRUCT. - NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIV.
4'-0"

ATTIC ACCESS AS 3'-8" 7'-6" 2'-10"


SHALL BE APPLIED TO THE GARAGE CEILING ADJACENT TO
REQUIRED

OFFICE - RE: DETAIL


TO DRAIN
HABITABLE ROOMS ABOVE THE GARAGE.
COV.

SLOPE

DOUBLE HOME
OPT. SINGLE /
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE STRUCTURE(S) SUPPORTING FLOOR AND
16080 GD SOFFIT ABV. PORCH CEILING ASSEMBLIES.
(TYP.) STUDY

14'-3"

14'-3"
CONC. - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. APPLIED

HB
90 CLG. TO THE INTERIOR SIDE OF THE EXTERIOR WALL OF A
GARAGE LOCATED LESS THAN 3'-0" FROM A DWELLING UNIT
ON THE SAME LOT.
COLUMN ALL DOORS LEADING INTO GARAGES FROM LIVING SPACES
TO BE MINIMUM TIGHT FITTING, WEATHER-STRIPPED,

12'-0"
RE: DETAIL
20-MINUTE FIRE-RATED, OR 1 3/8" THICK SOLID WOOD, OR
8'-0"

STEPS PER
1 3/8" THICK SOLID OR HONEYCOMB CORE STEEL DOORS
GRADE
EQUIPPED WITH SELF-CLOSING OR AUTOMATIC-CLOSING
DEVICE PER R302.5.1.
HOSE BIB:
ALL HOSE BIBBS ARE "FROSTPROOF" TYPE PER R2903.10.
HOSE BIBB BLEED PER P2903.8.5.

WALL LEGEND
3050 SH 3050 SH
2x4 (3 1/2") STUD WALL
2 TYPICAL INTERIOR WALL (U.N.O)
A6.0
2x6 (5 1/2") STUD WALL
TYPICAL EXTERIOR WALL (U.N.O.)

FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"


HIGH AT MAIN AND UPPER LEVEL (U.N.O)
10'-6" 10'-6" 7'-0" 7'-0" 5'-3" 3'-6" 5'-3"

21'-0" 14'-0" 14'-0"

49'-0"

MAIN LEVEL FLOOR PLAN - 'B'


1 SCALE: 1/4" = 1'-0"
©
MAIN / UPPER PLAN NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT SHOWN OR NOTED ON PLANS
ALL NON 90° ANGLES ARE 45°, U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
Godden|Sudik
TYPICAL GUARDRAIL MIN. 36" ABOVE THE ADJACENT
A R C H I T E C T S
FINISHED FLOOR AND SHALL NOT HAVE OPENINGS WHICH SEE WHAT COULD BE
ALLOW THE PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPEC'S.

COUNTERTOP:
36" H. ON BASE CABINETS, BACKSPLASH PER BUILDER.
UPPER WALL CABINETS:
12" D. CABINETS INDICATED BY DASHED LINE ON PLAN,
TYP. CABINET HEIGHTS WILL VARY PER BUILDER, U.N.O.
SINK:
PROVIDE DISPOSAL, SWITCH POWER. RE: ELECT. PLANS.
REFRIGERATOR:
COORDINATE PLUMBING FOR WATER LINE AS REQUIRED.

FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT


GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM SHALL
BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS PER R702.4.2.
BATHTUB AND SHOWER FLOORS AND WALLS ABOVE
49'-0" BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL
11'-0" 38'-0" EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE
THE FLOOR PER R307.2.
COUNTERTOP:
9'-0 1/2" 13'-9" 7'-10 1/2" 7'-4" 30" H. ON BASE CABINETS (U.N.O.), BACKSPLASH AND
COLUMN AT OPT. MIRROR ABOVE PER BUILDER.
EXT. COVERED A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
PATIO OPT. PATIO OPT. EXT. CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE
COVERED PATIO WALL, PARTITION, VANITY OR CLOSER THAN 30 INCHES
CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE
COLUMN AT SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES IN
COLUMN AT COLUMN AT FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO ANY
ENHANCED
OPT. EXT. COVERED OPT. EXT. COVERED WALL, FIXTURE OR DOOR PER R307.1, P2705.1.
ELEVATION W/
PATIO PATIO
OPT. EXT.
COVERED PATIO CLOTHES WASHER/DRYER LOCATION:

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SIDE-BY-SIDE WASHER/DRYER PLUMBING, ELECTRICAL,
36" x 36" CONC. AND EXHAUST SHALL BE CONFIGURED TO ALLOW FOR THE
STOOP W/ STEPS WASHER TO BE INSTALLED AND ORIENTED ON THE LEFT
PER GRADE SIDE WHEN FACING THE APPLIANCES.
SHELVING OR CABINETRY PER PLAN AND BUILDER SPEC'S.
LAUNDRY SINK PER PLAN AND BUILDER SPEC'S.
DRYER VENT:
HB INSTALL A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE
5050 SL

PHONE: 303-770-8300
5050 SL 6080 SGD (T) STEP EXTERIOR. VENT MUST BE EQUIPPED WITH A BACKDRAFT
DAMPER PER G2439.3. THE MAXIMUM LENGTH OF THE
EXHAUST DUCT SHALL BE 35' FROM THE CONNECTION TO
THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET

3'-10 1/2"
TERMINAL. WHERE FITTINGS ARE USED, THE MAX. LENGTH
OF THE EXHAUST DUCT SHALL BE REDUCED IN
5 1/2" ACCORDANCE WITH TABLE G2439.7.4.1.
8'-5 1/2"
CLOTHES WASHER PAN AND FLOOR DRAIN:
FLOOR DRAIN INSTALLATION AND LOCATION TO COMPLY
30" COOKTOP WITH P2719.1.
PROVIDED AT
BUILDER TO FIELD VERIFY FLOOR DRAIN LOCATION WITH

DW
OPT. GOURMET
FLOOR FRAMING LAYOUT. ADJUST FRAMING AS REQUIRED

30" SLIDE-IN

MICRO ABV.
KITCHEN W/

RANGE w/
PRIOR TO FLOOR DRAIN INSTALLATION.

36" H. ISLAND
VENTED MICRO
PROVIDE AN APPROVED PAN UNDER WASHER AND
GREAT ABV.

6'-4"

DBL SNK
COORDINATE FLOOR DRAIN LOCATION WITH THE PAN

FIREPLACE
ROOM DINING "TYPE" PER BUILDER SPEC'S.

16'-0"

OPT.
90 CLG. 90 CLG. KITCHEN LOCATE WASHER GRAY BOX AS REQUIRED PER CODE.

90 CLG. STACKED CLOTHES WASHER/DRYER UNITS:


ACCESS, PLUMBING, ELECTRICAL AND EXHAUST, SIMILAR IN
APPLICATION AND CODE COMPLIANCE.

17'-6 1/2"
21'-8"

19'-10"
34 1/2" H. 2 x 6
3 1/2" 7" KNEE WALL BLW. FURNACE AND HOT WATER HEATER:
FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
11'-0" 10'-2" 4'-6" 3'-0" 4'-9" 7'-7" 7'-1 1/2" UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.

OPT. 36" REF


PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24

5'-9 1/2"
DBL. OVEN
PROVIDED AT THE PRESSURE RELIEF VALVE FOR THE WATER HEATER
MUST DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY

5 1/2"
OPT. GOURMET
MECH. KITCHEN A FLOOR DRAIN, PER M2002.4 AND P2804.
CHASE WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN
PAN MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST
BE AT LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER

LANDING
STEP

9 1/2"
P2801.6.2.

2040 FX
4'-0"
2'-11 1/2"

3'-6"
4'-8"

3'-9"
1'-10 1/2"

4'-0"
CL

28

68

2'-3 1/2"
37'-0"

68

SHELVES
R & S:

26
UP

(4) 16"

6'-8 1/2"
PR
3'-6" 3'-9 1/2" INDICATES ROD & SHELF IN CLOSETS, "(2) R & S"
INDICATES (1) HIGH ROD AND (1) LOW ROD PLUS SHELF.
SHELVES ARE 12" DEEP, U.N.O.
@ ENH. ELEV.

3'-1 1/2"

2468
FIREPLACE:

(4) 16" SH
36" H. KNEE WALL w/ CAP
GAS FIREPLACE (PER BUILDER) W/ DIRECT VENT OR B-VENT
4020 FX

7 T @ 10" = 5'-10"
PANTRY

16R AT OPT. FULL


PER PLANS. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

4'-9 1/2"
STEPS PER GRADE

- OPT. OPEN RAIL

5" LOWER LEVEL


(ALTERNATE STAIRS REFER TO INTERIOR ELEVATIONS FOR DIMENSIONS AND
45'-0"

45'-0"
3-BAY

HANDRAIL
90 CLG.

5'-11 1/2"
DESIGN LAYOUT. MANUFACTURER'S INSTALLATION

6'-10"
AS REQ.)

8'-4"

14R /
GARAGE MUD INSTRUCTIONS FOR ALL FIREPLACES MUST BE KEPT ON SITE
FOR VERIFICATION AND INSPECTION OF REQUIRED
(4) 16" SH
CONC. ROOM CLEARANCES TO COMBUSTIBLE MATERIAL. ALL FIREPLACES

3'-6"
TO BE UL LISTED & PROVIDED WITH A READY ACCESSIBLE
90 CLG.

5 1/2"
SHUT-OFF VALVE PER THE (IFGC) INTERNATIONAL FUEL GAS
5'-6" 2'-0" CODE SEC. 409.5.
ATTIC ACCESS:

DN

4'-2"
THE ROUGHED-FRAMED OPENING SHALL NOT BE LESS

16R
UP

5 1/2"

6'-1 1/2"
THAN 22"x30" AND SHALL BE LOCATED IN A HALLWAY OR
P.R.

68
3'-11 1/2"
4'-1 1/2"
FLOOR OTHER READILY ACCESSIBLE LOCATION PER R807.1.

28
FOYER

4'-3"
ABV. 90 CLG.

2040 SH
APPLIANCES IN ATTIC REQUIREMENTS PER M1305.1.2.
90 CLG. AIR BARRIER SEAL AND INSULATION PER N1102.2.4.

4068 BP

5 1/2"
R&S
15'-4"

6'-9 1/2"

1'-11 1/2"
2468

6'-4"
TO DRAIN
SLOPE

3080
DWELLING-GARAGE OPENING AND PENETRATION
PROTECTION, SHALL COMPLY WITH, SECTION R302.5.
2'-2" 5'-4" 6'-9 1/2" 5'-6 1/2" 7'-1 1/2" - DWELLING-GARAGE FIRE SEPARATION, SHALL COMPLY

2'-8 1/2"
FLOOR ABV. (TYP.), 22 x 30 WITH, TABLE R302.6. THIS PROVISION SHALL NOT APPLY TO
ADD 5/8" GYP. BOARD 3 1/2" 7" ATTIC GARAGE WALLS THAT ARE PERPENDICULAR TO THE
TO GARAGE CEILING ACCESS ADJACENT DWELLING UNIT WALL PER R302.6.
PER R302.6 CL - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
STEP
APPLIED TO THE GARAGE SIDE FROM THE RESIDENCE AND
IF GYP. BOARD IS 2040 SH
FNDN. CURB ATTICS.
APPLIED, PROVIDE
RE: STRUCT. - NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIV.
4'-0"

ATTIC ACCESS AS 3'-8" 7'-6" 2'-10"


SHALL BE APPLIED TO THE GARAGE CEILING ADJACENT TO
REQUIRED

TO DRAIN

OFFICE - RE: DETAIL


HABITABLE ROOMS ABOVE THE GARAGE.

SLOPE
COV.

DOUBLE HOME
OPT. SINGLE /
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE STRUCTURE(S) SUPPORTING FLOOR AND
16080 GD SOFFIT ABV. PORCH CEILING ASSEMBLIES.
(TYP.) STUDY

14'-3"

14'-3"
CONC. - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. APPLIED
2'-0"

HB
90 CLG. TO THE INTERIOR SIDE OF THE EXTERIOR WALL OF A
GARAGE LOCATED LESS THAN 3'-0" FROM A DWELLING UNIT
ON THE SAME LOT.
COLUMN ALL DOORS LEADING INTO GARAGES FROM LIVING SPACES
TO BE MINIMUM TIGHT FITTING, WEATHER-STRIPPED,

12'-0"
RE: DETAIL
20-MINUTE FIRE-RATED, OR 1 3/8" THICK SOLID WOOD, OR
8'-0"

STEPS PER
1 3/8" THICK SOLID OR HONEYCOMB CORE STEEL DOORS
GRADE
EQUIPPED WITH SELF-CLOSING OR AUTOMATIC-CLOSING
DEVICE PER R302.5.1.
HOSE BIB:
ALL HOSE BIBBS ARE "FROSTPROOF" TYPE PER R2903.10.
HOSE BIBB BLEED PER P2903.8.5.

WALL LEGEND
5050 SL
2x4 (3 1/2") STUD WALL
3 TYPICAL INTERIOR WALL (U.N.O)
A6.0
2x6 (5 1/2") STUD WALL
TYPICAL EXTERIOR WALL (U.N.O.)

FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"


HIGH AT MAIN AND UPPER LEVEL (U.N.O)
10'-6" 10'-6" 7'-0" 7'-0" 7'-0" 7'-0"

21'-0" 14'-0" 14'-0"

49'-0"

MAIN LEVEL FLOOR PLAN - 'C'


1 SCALE: 1/4" = 1'-0"
©
MAIN / UPPER PLAN NOTES
49'-0"
REFER TO GENERAL NOTES FOR ADDITIONAL
INFORMATION NOT SHOWN OR NOTED ON PLANS
26'-0" 12'-0" 11'-0" ALL NON 90° ANGLES ARE 45°, U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
Godden|Sudik
TYPICAL GUARDRAIL MIN. 36" ABOVE THE ADJACENT
A R C H I T E C T S
FINISHED FLOOR AND SHALL NOT HAVE OPENINGS WHICH SEE WHAT COULD BE
ALLOW THE PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
WINDOW AND DOOR CALLOUTS ON PLANS ARE

SLOPE TO DRAIN
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPEC'S.
18" H. BENCH
SLOPE TO DRAIN
COUNTERTOP:
PATIO 36" H. ON BASE CABINETS, BACKSPLASH PER BUILDER.

10'-0"
CONC. UPPER WALL CABINETS:
12" D. CABINETS INDICATED BY DASHED LINE ON PLAN,
7'-9 1/2" 4'-2 1/2"
TYP. CABINET HEIGHTS WILL VARY PER BUILDER, U.N.O.
SINK:
4834 PROVIDE DISPOSAL, SWITCH POWER. RE: ELECT. PLANS.
OPT. STEP
SHOWER REFRIGERATOR:
PER GRADE
COORDINATE PLUMBING FOR WATER LINE AS REQUIRED.

6080 SGD (T) STEP FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT
BATH 3 GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM SHALL
BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER
90 CLG. AREAS AND WALL PANELS IN SHOWER AREAS PER R702.4.2.
BATHTUB AND SHOWER FLOORS AND WALLS ABOVE
3-BAY GREAT BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
2040 SH WINDOW
2468 REMOVED GARAGE ROOM DINING KITCHEN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL
CONC. 90 CLG. 90 CLG. 90 CLG. EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE
THE FLOOR PER R307.2.
COUNTERTOP:
30" H. ON BASE CABINETS (U.N.O.), BACKSPLASH AND
MIRROR ABOVE PER BUILDER.
REFER TO STANDARD PLAN

OPT. SHOWER OPT. PATIO FOR MORE INFORMATION A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE

5 AT BATH 3 SCALE: 1/4" = 1'-0" 1 ALL ELEVATION SIMILAR SCALE: 1/4" = 1'-0"
WALL, PARTITION, VANITY OR CLOSER THAN 30 INCHES
CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE
SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES IN
FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO ANY
WALL, FIXTURE OR DOOR PER R307.1, P2705.1.

CLOTHES WASHER/DRYER LOCATION:

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


49'-0" SIDE-BY-SIDE WASHER/DRYER PLUMBING, ELECTRICAL,
AND EXHAUST SHALL BE CONFIGURED TO ALLOW FOR THE
WASHER TO BE INSTALLED AND ORIENTED ON THE LEFT
26'-0" 23'-0" SIDE WHEN FACING THE APPLIANCES.
SHELVING OR CABINETRY PER PLAN AND BUILDER SPEC'S.
FLOATING SHLVS. 12'-0" 11'-0" LAUNDRY SINK PER PLAN AND BUILDER SPEC'S.
(MERILLAT
DRYER VENT:
FLS30-CTNON OR
INSTALL A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE
SIM.)

PHONE: 303-770-8300
EXTERIOR. VENT MUST BE EQUIPPED WITH A BACKDRAFT
DAMPER PER G2439.3. THE MAXIMUM LENGTH OF THE

2'-0"
SOLID SURFACE EXHAUST DUCT SHALL BE 35' FROM THE CONNECTION TO
2'-0"

36" HEAT &

SLOPE TO DRAIN
DESKTOP THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET
GLO COLUMN TERMINAL. WHERE FITTINGS ARE USED, THE MAX. LENGTH
SLIMLINE F.P. EXT. OF THE EXHAUST DUCT SHALL BE REDUCED IN
BASE CABS.
(MERILLAT DDR15 / SOFFIT ABV. COVERED ACCORDANCE WITH TABLE G2439.7.4.1.
2'-0"

DDO15 R/L OR SIM.) 4'-0 1/2" 3'-6" 3'-6" 4'-0 1/2" CLOTHES WASHER PAN AND FLOOR DRAIN:
PATIO FLOOR DRAIN INSTALLATION AND LOCATION TO COMPLY

10'-0"
CONC. WITH P2719.1.
CL
2'-6 1/2"

6'-9 1/2" 16'-2 1/2" BUILDER TO FIELD VERIFY FLOOR DRAIN LOCATION WITH
OPT. STEP FLOOR FRAMING LAYOUT. ADJUST FRAMING AS REQUIRED
PER GRADE PRIOR TO FLOOR DRAIN INSTALLATION.
PROVIDE AN APPROVED PAN UNDER WASHER AND
COORDINATE FLOOR DRAIN LOCATION WITH THE PAN
EQ. 1'-3" 1'-3" 3'-0" 1'-3" 1'-3" EQ. WALL MATERIAL "TYPE" PER BUILDER SPEC'S.
PER BUILDER
LOCATE WASHER GRAY BOX AS REQUIRED PER CODE.
FIREPLACE VENT 8080 SGD (T) STEP
STACKED CLOTHES WASHER/DRYER UNITS:
(2) SHELVES ABV. ACCESS, PLUMBING, ELECTRICAL AND EXHAUST, SIMILAR IN
APPLICATION AND CODE COMPLIANCE.
BASE CABS. BLW.
+0" +24" +0" 3-BAY GREAT FURNACE AND HOT WATER HEATER:
GARAGE ROOM DINING KITCHEN FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
MILLWORK UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
90 CLG. 90 CLG. 90 CLG.
1'-9"

SURROUND CONC. PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24
BEHIND CAB. BLW.

TV LOCATION
3" FILLER PANEL

DESK PER BUILDER THE PRESSURE RELIEF VALVE FOR THE WATER HEATER

9'-0"
MUST DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY
A FLOOR DRAIN, PER M2002.4 AND P2804.
EQ. 8'-0" EQ. REFER TO STANDARD PLAN WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
TILE
SURROUND 36" HEAT 4'-2" OPT. EXT. COVERED PATIO FOR MORE INFORMATION LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN
PAN MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST

REFER TO STANDARD PLAN


PER BUILDER & GLO
SLIMLINE
F.P.
2 ALL ELEVATION SIMILAR SCALE: 1/4" = 1'-0"
BE AT LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER
P2801.6.2.

FOR MORE INFORMATION


R & S:
INDICATES ROD & SHELF IN CLOSETS, "(2) R & S"
INDICATES (1) HIGH ROD AND (1) LOW ROD PLUS SHELF.

OPT. SINGLE HOME SHELVES ARE 12" DEEP, U.N.O.

OPT. 36" REF


3'-11 1/2" 7'-1" 3'-11 1/2"
KITCHEN FIREPLACE:
90 CLG. GAS FIREPLACE (PER BUILDER) W/ DIRECT VENT OR B-VENT

OFFICE @ STUDY OPT. FIREPLACE


PER PLANS. INSTALL PER MANUFACTURER'S INSTRUCTIONS.
REFER TO INTERIOR ELEVATIONS FOR DIMENSIONS AND

8 6
DESIGN LAYOUT. MANUFACTURER'S INSTALLATION
INSTRUCTIONS FOR ALL FIREPLACES MUST BE KEPT ON SITE
SCALE: 1/4" = 1'-0" AT GREAT ROOM SCALE: 1/4" = 1'-0" FOR VERIFICATION AND INSPECTION OF REQUIRED
CLEARANCES TO COMBUSTIBLE MATERIAL. ALL FIREPLACES

2040 FX
2'-6 3/4" 2'-6 3/4" 2'-3 1/2" TO BE UL LISTED & PROVIDED WITH A READY ACCESSIBLE
SHUT-OFF VALVE PER THE (IFGC) INTERNATIONAL FUEL GAS
PANTRY

1'-8 1/2"
2'-3 1/2"
CODE SEC. 409.5.
90 CLG. ATTIC ACCESS:

68
THE ROUGHED-FRAMED OPENING SHALL NOT BE LESS

18
PR
THAN 22"x30" AND SHALL BE LOCATED IN A HALLWAY OR
OTHER READILY ACCESSIBLE LOCATION PER R807.1.
(4) 16" SH APPLIANCES IN ATTIC REQUIREMENTS PER M1305.1.2.
AIR BARRIER SEAL AND INSULATION PER N1102.2.4.

2'-11 1/2"
DWELLING-GARAGE OPENING AND PENETRATION
5050 SL PROTECTION, SHALL COMPLY WITH, SECTION R302.5.
- DWELLING-GARAGE FIRE SEPARATION, SHALL COMPLY
WITH, TABLE R302.6. THIS PROVISION SHALL NOT APPLY TO
GARAGE WALLS THAT ARE PERPENDICULAR TO THE
ADJACENT DWELLING UNIT WALL PER R302.6.

8'-9"
UPPER CABS. - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
30" x 60"
(MERILLAT BK2454
BATH 3 TUB/SHOWER APPLIED TO THE GARAGE SIDE FROM THE RESIDENCE AND

6'-3 1/2"
OR SIM.)

5'-9 1/2"
OR OPT. 4834 ATTICS.
90 CLG. - NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIV.
SHOWER W/
SOLID SURFACE SHALL BE APPLIED TO THE GARAGE CEILING ADJACENT TO
2'-0"

OPT. OVEN 12" BENCH


DESKTOP 42" HEAT & GLO BLW.
FOYER 1'-5 1/2" HABITABLE ROOMS ABOVE THE GARAGE.
COSMO F.P. - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE

36" COOKTOP &


DW 90 CLG. 4'-11 1/2" 2040 SH WINDOW
MILLWORK BUILT

HOOD VENT
2468 APPLIED TO THE STRUCTURE(S) SUPPORTING FLOOR AND
END PANEL REMOVED
CEILING ASSEMBLIES.
36" H. ISLAND

CL - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. APPLIED


4'-0 1/2" 3'-6" 3'-6" 4'-0 1/2" TO THE INTERIOR SIDE OF THE EXTERIOR WALL OF A
DBL SNK

R&S GARAGE LOCATED LESS THAN 3'-0" FROM A DWELLING UNIT

2'-8"
2668
ON THE SAME LOT.
CL
2'-6 1/2"

ALL DOORS LEADING INTO GARAGES FROM LIVING SPACES


CHEF'S TO BE MINIMUM TIGHT FITTING, WEATHER-STRIPPED,
KITCHEN 5068 BP 20-MINUTE FIRE-RATED, OR 1 3/8" THICK SOLID WOOD, OR
1 3/8" THICK SOLID OR HONEYCOMB CORE STEEL DOORS
90 CLG. 22 x 30 EQUIPPED WITH SELF-CLOSING OR AUTOMATIC-CLOSING
EQ. 3'-0" 2'-0" 3'-0" EQ. ATTIC DEVICE PER R302.5.1.
WALL MATERIAL 34 1/2" H. 2 x 6 ACCESS
PER BUILDER KNEE WALL BLW. HOSE BIB:
BASE CABS.
(MERILLAT DDO24 5'-1 1/2" 8'-10 1/2" ALL HOSE BIBBS ARE "FROSTPROOF" TYPE PER R2903.10.
FIREPLACE VENT
HOSE BIBB BLEED PER P2903.8.5.
R/L OR SIM.)
OPT. 36" REF

14'-8 1/2"
BASE & WALL LEGEND

HB
UPPER CABS.
OVEN / BEDROOM 5

12'-0 1/2"
MICRO
+0" +24" +0" COMBO 90 CLG. 2x4 (3 1/2") STUD WALL
TYPICAL INTERIOR WALL (U.N.O)
1'-9"

TV LOCATION 2x6 (5 1/2") STUD WALL


DESK
2040 FX

TYPICAL EXTERIOR WALL (U.N.O.)


9'-0"

EQ. 8'-0" EQ. FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"


1'-2"

42" HEAT
& GLO HIGH AT MAIN AND UPPER LEVEL (U.N.O)
PANEL BEHIND

COSMO F.P.
4'-2"
CAB. BLW.
3" FILLER

2'-3"

REFER TO STANDARD PLAN


6"

FOR MORE INFORMATION


5050 SL REFER TO STANDARD PLAN
FOR MORE INFORMATION
VENEER

OPT. DOUBLE HOME


PER BUILDER
REFER TO STANDARD PLAN WINDOWS VARY PER ELEVATION,
3'-11 1/2" 7'-1" 3'-11 1/2" FOR MORE INFORMATION REFER TO BASE PLANS & ELEVATIONS
FOR LOCATION AND SIZE OF WINDOWS.

OFFICE @ STUDY OPT. LINEAR FIREPLACE OPT. CHEF'S KITCHEN OPT. BEDROOM 5
9 SCALE: 1/4" = 1'-0" 7 OPT 42" FIREPLACE SHOWN AT GREAT ROOM SCALE: 1/4" = 1'-0" 4 SCALE: 1/4" = 1'-0" 3 SCALE: 1/4" = 1'-0" ©
MAIN / UPPER PLAN NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT SHOWN OR NOTED ON PLANS
ALL NON 90° ANGLES ARE 45°, U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
Godden|Sudik
TYPICAL GUARDRAIL MIN. 36" ABOVE THE ADJACENT
A R C H I T E C T S
FINISHED FLOOR AND SHALL NOT HAVE OPENINGS WHICH SEE WHAT COULD BE
ALLOW THE PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPEC'S.

COUNTERTOP:
36" H. ON BASE CABINETS, BACKSPLASH PER BUILDER.
UPPER WALL CABINETS:
12" D. CABINETS INDICATED BY DASHED LINE ON PLAN,
TYP. CABINET HEIGHTS WILL VARY PER BUILDER, U.N.O.
SINK:
PROVIDE DISPOSAL, SWITCH POWER. RE: ELECT. PLANS.
REFRIGERATOR:
COORDINATE PLUMBING FOR WATER LINE AS REQUIRED.

49'-0"
FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT
1'-1 3/4" 8 1/2" 11 3/4" GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM SHALL
12'-6 1/2" 5'-3 1/2" 15'-7 1/2" 4'-0" 5'-0" 3'-8 1/2" BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS PER R702.4.2.
BATHTUB AND SHOWER FLOORS AND WALLS ABOVE
6'-6" 6'-0 1/2" 7'-11 1/2" 7'-8" 2'-6" 2'-6" BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL
EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE
THE FLOOR PER R307.2.
COLUMN AT OPT. OPT. EXT. COVERED COLUMN AT OPT.
EXT. COVERED PATIO BLW. EXT. COVERED COUNTERTOP:
PATIO BLW. PATIO BLW. 30" H. ON BASE CABINETS (U.N.O.), BACKSPLASH AND
MIRROR ABOVE PER BUILDER.
A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE
WALL, PARTITION, VANITY OR CLOSER THAN 30 INCHES
CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE
SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES IN
FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO ANY
WALL, FIXTURE OR DOOR PER R307.1, P2705.1.

CLOTHES WASHER/DRYER LOCATION:

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SIDE-BY-SIDE WASHER/DRYER PLUMBING, ELECTRICAL,
AND EXHAUST SHALL BE CONFIGURED TO ALLOW FOR THE
WASHER TO BE INSTALLED AND ORIENTED ON THE LEFT
SIDE WHEN FACING THE APPLIANCES.
SHELVING OR CABINETRY PER PLAN AND BUILDER SPEC'S.
LAUNDRY SINK PER PLAN AND BUILDER SPEC'S.
DRYER VENT:
INSTALL A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE
5050 SL

PHONE: 303-770-8300
4050 SL 4040 SL (T) EXTERIOR. VENT MUST BE EQUIPPED WITH A BACKDRAFT
DAMPER PER G2439.3. THE MAXIMUM LENGTH OF THE
EXHAUST DUCT SHALL BE 35' FROM THE CONNECTION TO

2'-0"
THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET
TERMINAL. WHERE FITTINGS ARE USED, THE MAX. LENGTH

2040 SH

4'-2 1/2"
30" x 60"

4'-3"

4'-3"
TUB/SHOWER 60" x 42" OF THE EXHAUST DUCT SHALL BE REDUCED IN
BEDROOM 4 PRIMARY TUB ACCORDANCE WITH TABLE G2439.7.4.1.

6'-3 1/2"
SUITE 4842

6'-6"
80 CLG. CLOTHES WASHER PAN AND FLOOR DRAIN:
SHOWER FLOOR DRAIN INSTALLATION AND LOCATION TO COMPLY
80 CLG. WITH P2719.1.
TEMP.

10'-0"
GLAZING BUILDER TO FIELD VERIFY FLOOR DRAIN LOCATION WITH
36" H.

2468
FLOOR FRAMING LAYOUT. ADJUST FRAMING AS REQUIRED

3'-8 1/2"
12'-5 1/2" KNEEWALL

2040 SH
PRIOR TO FLOOR DRAIN INSTALLATION.
PRIMARY

5'-4 1/2"
PROVIDE AN APPROVED PAN UNDER WASHER AND

5'-9 1/2"
10'-5 1/2"
BATH 2468 COORDINATE FLOOR DRAIN LOCATION WITH THE PAN
OPT. "TYPE" PER BUILDER SPEC'S.

3'-8 1/2"
80 CLG.

16'-0"
LAVATORY
LOCATE WASHER GRAY BOX AS REQUIRED PER CODE.

2'-0 1/2"
BATH 2

5'-6 1/2"
STACKED CLOTHES WASHER/DRYER UNITS:
80 CLG. (4) 16" SH. ACCESS, PLUMBING, ELECTRICAL AND EXHAUST, SIMILAR IN
APPLICATION AND CODE COMPLIANCE.

2468
R&S

3'-1"
5 1/2" 2468 FURNACE AND HOT WATER HEATER:

9 1/2"
3'-6" 11'-7" FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
5068 BP
UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24
2'-4 1/2"

6'-0"

7'-6 1/2"
ACCESS
24
THE PRESSURE RELIEF VALVE FOR THE WATER HEATER

R&S
22 x 30
ATTIC
68
4'-1 1/2"
MUST DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY

2668
R&S A FLOOR DRAIN, PER M2002.4 AND P2804.
5'-0 1/2"

2'-6"
(4) WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
30'-9"

30'-9"
2668 16" SH. LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN
R&S W.I.C.

12'-1"
2'-8"

PAN MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST


33'-0"

33'-0"
80 CLG. BE AT LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER

3'-9 1/2"

LANDING
HALL P2801.6.2.

2040 SH
4'-0"
LANDING
2668
80 CLG.

3'-11"

3'-9"
4'-0"
3'-9"
5068 BP
R & S:
2040 SH

8'-11 1/2" 3'-10 1/2" 12'-1" 2'-8" 6'-5" 4'-1" 3'-9 1/2" 7'-1 1/2"
INDICATES ROD & SHELF IN CLOSETS, "(2) R & S"

4'-6 1/2"
1'-6 1/2"

INDICATES (1) HIGH ROD AND (1) LOW ROD PLUS SHELF.

R&S
SHELVES ARE 12" DEEP, U.N.O.

KNEE WALL w/ CAP


- OPT. OPEN RAIL
FIREPLACE:

9'-11"
2668
GAS FIREPLACE (PER BUILDER) W/ DIRECT VENT OR B-VENT

7 T @ 10" = 5'-10"
(4) 16" SH.
R&S PER PLANS. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

HANDRAIL
6'-1 1/2"
68
REFER TO INTERIOR ELEVATIONS FOR DIMENSIONS AND

4'-0"
24
DESIGN LAYOUT. MANUFACTURER'S INSTALLATION

5'-7"
INSTRUCTIONS FOR ALL FIREPLACES MUST BE KEPT ON SITE
BEDROOM 2 FOR VERIFICATION AND INSPECTION OF REQUIRED
13'-3"

80 CLG. CLEARANCES TO COMBUSTIBLE MATERIAL. ALL FIREPLACES


11'-8 1/2"

(W) (D) TO BE UL LISTED & PROVIDED WITH A READY ACCESSIBLE


10'-10"

SHUT-OFF VALVE PER THE (IFGC) INTERNATIONAL FUEL GAS


STD. SHELF CODE SEC. 409.5.

16R
DN
ABOVE W/D

8'-8"
ATTIC ACCESS:
DR. OPT. UPPER THE ROUGHED-FRAMED OPENING SHALL NOT BE LESS

6'-10"
BEDROOM 3 LAUNDRY
CABS. THAN 22"x30" AND SHALL BE LOCATED IN A HALLWAY OR
OTHER READILY ACCESSIBLE LOCATION PER R807.1.

4'-8"
80 CLG.

R&S

4'-10"
5068 BP
80 CLG. APPLIANCES IN ATTIC REQUIREMENTS PER M1305.1.2.
AIR BARRIER SEAL AND INSULATION PER N1102.2.4.

2868
DWELLING-GARAGE OPENING AND PENETRATION
PROTECTION, SHALL COMPLY WITH, SECTION R302.5.
4040 SL - DWELLING-GARAGE FIRE SEPARATION, SHALL COMPLY
2'-3"

2'-3"
2036 FX 2036 FX WITH, TABLE R302.6. THIS PROVISION SHALL NOT APPLY TO
GARAGE WALLS THAT ARE PERPENDICULAR TO THE
ADJACENT DWELLING UNIT WALL PER R302.6.
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE GARAGE SIDE FROM THE RESIDENCE AND
5050 SL
ATTICS.
- NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIV.
SHALL BE APPLIED TO THE GARAGE CEILING ADJACENT TO
HABITABLE ROOMS ABOVE THE GARAGE.
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE STRUCTURE(S) SUPPORTING FLOOR AND
CEILING ASSEMBLIES.
ROOF BLW. - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. APPLIED
TO THE INTERIOR SIDE OF THE EXTERIOR WALL OF A
GARAGE LOCATED LESS THAN 3'-0" FROM A DWELLING UNIT
ON THE SAME LOT.
ALL DOORS LEADING INTO GARAGES FROM LIVING SPACES
TO BE MINIMUM TIGHT FITTING, WEATHER-STRIPPED,
20-MINUTE FIRE-RATED, OR 1 3/8" THICK SOLID WOOD, OR
1 3/8" THICK SOLID OR HONEYCOMB CORE STEEL DOORS
EQUIPPED WITH SELF-CLOSING OR AUTOMATIC-CLOSING
1 DEVICE PER R302.5.1.
A6.0 HOSE BIB:
ALL HOSE BIBBS ARE "FROSTPROOF" TYPE PER R2903.10.
HOSE BIBB BLEED PER P2903.8.5.

WALL LEGEND
2x4 (3 1/2") STUD WALL
TYPICAL INTERIOR WALL (U.N.O)

2x6 (5 1/2") STUD WALL


TYPICAL EXTERIOR WALL (U.N.O.)

7'-8" 4'-10 1/2" 5'-2" 4'-1 1/2" 4'-10"


FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"
HIGH AT MAIN AND UPPER LEVEL (U.N.O)
6'-5" 5'-11 1/2" 12'-6 1/2" 2'-10" 14'-1 1/2" 6'-8" 5 1/2"

12'-4 1/2" 15'-4 1/2" 21'-3"

49'-0"

UPPER LEVEL FLOOR PLAN - 'A'


1 SCALE: 1/4" = 1'-0"
©
MAIN / UPPER PLAN NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT SHOWN OR NOTED ON PLANS
ALL NON 90° ANGLES ARE 45°, U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
Godden|Sudik
TYPICAL GUARDRAIL MIN. 36" ABOVE THE ADJACENT
A R C H I T E C T S
FINISHED FLOOR AND SHALL NOT HAVE OPENINGS WHICH SEE WHAT COULD BE
ALLOW THE PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPEC'S.

COUNTERTOP:
36" H. ON BASE CABINETS, BACKSPLASH PER BUILDER.
UPPER WALL CABINETS:
12" D. CABINETS INDICATED BY DASHED LINE ON PLAN,
TYP. CABINET HEIGHTS WILL VARY PER BUILDER, U.N.O.
SINK:
PROVIDE DISPOSAL, SWITCH POWER. RE: ELECT. PLANS.
REFRIGERATOR:
COORDINATE PLUMBING FOR WATER LINE AS REQUIRED.

49'-0"
FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT
1'-1 3/4" 8 1/2" 11 3/4" GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM SHALL
12'-6 1/2" 5'-3 1/2" 15'-7 1/2" 4'-0" 5'-0" 3'-8 1/2" BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS PER R702.4.2.
BATHTUB AND SHOWER FLOORS AND WALLS ABOVE
6'-6" 6'-0 1/2" 3'-11 1/2" 4'-0" 4'-0" 3'-8" 2'-6" 2'-6" BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL
EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE
THE FLOOR PER R307.2.
COLUMN AT OPT. OPT. EXT. COVERED COLUMN AT OPT.
EXT. COVERED PATIO BLW. EXT. COVERED COUNTERTOP:
PATIO BLW. PATIO BLW. 30" H. ON BASE CABINETS (U.N.O.), BACKSPLASH AND
MIRROR ABOVE PER BUILDER.
A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE
WALL, PARTITION, VANITY OR CLOSER THAN 30 INCHES
CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE
SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES IN
FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO ANY
WALL, FIXTURE OR DOOR PER R307.1, P2705.1.

CLOTHES WASHER/DRYER LOCATION:

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SIDE-BY-SIDE WASHER/DRYER PLUMBING, ELECTRICAL,
AND EXHAUST SHALL BE CONFIGURED TO ALLOW FOR THE
WASHER TO BE INSTALLED AND ORIENTED ON THE LEFT
SIDE WHEN FACING THE APPLIANCES.
SHELVING OR CABINETRY PER PLAN AND BUILDER SPEC'S.
LAUNDRY SINK PER PLAN AND BUILDER SPEC'S.
DRYER VENT:
INSTALL A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE
3050 SH 4050 FX 3050 SH

PHONE: 303-770-8300
4050 SL 4040 SL (T) EXTERIOR. VENT MUST BE EQUIPPED WITH A BACKDRAFT
DAMPER PER G2439.3. THE MAXIMUM LENGTH OF THE
EXHAUST DUCT SHALL BE 35' FROM THE CONNECTION TO

2'-0"
THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET
TERMINAL. WHERE FITTINGS ARE USED, THE MAX. LENGTH

2040 SH

4'-2 1/2"
30" x 60"

4'-3"

4'-3"
TUB/SHOWER 60" x 42" OF THE EXHAUST DUCT SHALL BE REDUCED IN
BEDROOM 4 PRIMARY TUB ACCORDANCE WITH TABLE G2439.7.4.1.

6'-3 1/2"
SUITE 4842

6'-6"
80 CLG. CLOTHES WASHER PAN AND FLOOR DRAIN:
SHOWER FLOOR DRAIN INSTALLATION AND LOCATION TO COMPLY
80 CLG. WITH P2719.1.
TEMP.

10'-0"
GLAZING BUILDER TO FIELD VERIFY FLOOR DRAIN LOCATION WITH
36" H.

2468
FLOOR FRAMING LAYOUT. ADJUST FRAMING AS REQUIRED

3'-8 1/2"
12'-5 1/2" KNEEWALL

2040 SH
PRIOR TO FLOOR DRAIN INSTALLATION.
PRIMARY

5'-4 1/2"
PROVIDE AN APPROVED PAN UNDER WASHER AND

5'-9 1/2"
10'-5 1/2"
BATH 2468 COORDINATE FLOOR DRAIN LOCATION WITH THE PAN
OPT. "TYPE" PER BUILDER SPEC'S.

3'-8 1/2"
80 CLG.

16'-0"
LAVATORY
LOCATE WASHER GRAY BOX AS REQUIRED PER CODE.

2'-0 1/2"
BATH 2

5'-6 1/2"
STACKED CLOTHES WASHER/DRYER UNITS:
80 CLG. (4) 16" SH. ACCESS, PLUMBING, ELECTRICAL AND EXHAUST, SIMILAR IN
APPLICATION AND CODE COMPLIANCE.

2468
R&S

3'-1"
5 1/2" 2468 FURNACE AND HOT WATER HEATER:

9 1/2"
3'-6" 11'-7" FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
5068 BP
UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24
2'-4 1/2"

6'-0"

7'-6 1/2"
ACCESS
24
THE PRESSURE RELIEF VALVE FOR THE WATER HEATER

R&S
22 x 30
ATTIC
68
4'-1 1/2"
MUST DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY

2668
R&S A FLOOR DRAIN, PER M2002.4 AND P2804.
5'-0 1/2"

2'-6"
WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
30'-9"

30'-9"
(4) 16" SH.
2668 LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN
R&S W.I.C.

12'-1"
2'-8"

PAN MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST


33'-0"

33'-0"
80 CLG. BE AT LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER

3'-9 1/2"

LANDING
HALL P2801.6.2.

2040 SH
4'-0"
LANDING
2668
80 CLG.

3'-11"

3'-9"
4'-0"
3'-9"
5068 BP
R & S:
2040 SH

8'-11 1/2" 3'-10 1/2" 12'-1" 2'-8" 6'-5" 4'-1" 3'-9 1/2" 7'-1 1/2"
INDICATES ROD & SHELF IN CLOSETS, "(2) R & S"

4'-6 1/2"
1'-6 1/2"

INDICATES (1) HIGH ROD AND (1) LOW ROD PLUS SHELF.

R&S
SHELVES ARE 12" DEEP, U.N.O.

KNEE WALL w/ CAP


- OPT. OPEN RAIL
FIREPLACE:

9'-11"
2668
GAS FIREPLACE (PER BUILDER) W/ DIRECT VENT OR B-VENT

7 T @ 10" = 5'-10"
(4) 16" SH.
R&S PER PLANS. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

HANDRAIL
6'-1 1/2"
68
REFER TO INTERIOR ELEVATIONS FOR DIMENSIONS AND

4'-0"
24
DESIGN LAYOUT. MANUFACTURER'S INSTALLATION

5'-7"
INSTRUCTIONS FOR ALL FIREPLACES MUST BE KEPT ON SITE
BEDROOM 2 FOR VERIFICATION AND INSPECTION OF REQUIRED
13'-3"

80 CLG. CLEARANCES TO COMBUSTIBLE MATERIAL. ALL FIREPLACES


11'-8 1/2"

(W) (D) TO BE UL LISTED & PROVIDED WITH A READY ACCESSIBLE


10'-10"

SHUT-OFF VALVE PER THE (IFGC) INTERNATIONAL FUEL GAS


STD. SHELF CODE SEC. 409.5.

16R
DN
ABOVE W/D

8'-8"
ATTIC ACCESS:
DR. OPT. UPPER THE ROUGHED-FRAMED OPENING SHALL NOT BE LESS

6'-10"
BEDROOM 3 LAUNDRY
CABS. THAN 22"x30" AND SHALL BE LOCATED IN A HALLWAY OR
OTHER READILY ACCESSIBLE LOCATION PER R807.1.

4'-8"
80 CLG.

R&S

4'-10"
5068 BP
80 CLG. APPLIANCES IN ATTIC REQUIREMENTS PER M1305.1.2.
AIR BARRIER SEAL AND INSULATION PER N1102.2.4.

2868
DWELLING-GARAGE OPENING AND PENETRATION
PROTECTION, SHALL COMPLY WITH, SECTION R302.5.
- DWELLING-GARAGE FIRE SEPARATION, SHALL COMPLY
2'-3"

2'-3"
4040 SL 2020 FX 2020 FX 2020 FX WITH, TABLE R302.6. THIS PROVISION SHALL NOT APPLY TO
GARAGE WALLS THAT ARE PERPENDICULAR TO THE
ADJACENT DWELLING UNIT WALL PER R302.6.
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE GARAGE SIDE FROM THE RESIDENCE AND
3050 SH 3050 SH
ATTICS.
- NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIV.
SHALL BE APPLIED TO THE GARAGE CEILING ADJACENT TO
HABITABLE ROOMS ABOVE THE GARAGE.
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE STRUCTURE(S) SUPPORTING FLOOR AND
CEILING ASSEMBLIES.
ROOF BLW. - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. APPLIED
TO THE INTERIOR SIDE OF THE EXTERIOR WALL OF A
GARAGE LOCATED LESS THAN 3'-0" FROM A DWELLING UNIT
ON THE SAME LOT.
ALL DOORS LEADING INTO GARAGES FROM LIVING SPACES
TO BE MINIMUM TIGHT FITTING, WEATHER-STRIPPED,
20-MINUTE FIRE-RATED, OR 1 3/8" THICK SOLID WOOD, OR
1 3/8" THICK SOLID OR HONEYCOMB CORE STEEL DOORS
EQUIPPED WITH SELF-CLOSING OR AUTOMATIC-CLOSING
2 DEVICE PER R302.5.1.
A6.0 HOSE BIB:
ALL HOSE BIBBS ARE "FROSTPROOF" TYPE PER R2903.10.
HOSE BIBB BLEED PER P2903.8.5.

WALL LEGEND
2x4 (3 1/2") STUD WALL
TYPICAL INTERIOR WALL (U.N.O)

2x6 (5 1/2") STUD WALL


TYPICAL EXTERIOR WALL (U.N.O.)

5'-11 1/8" 3'-6 1/8" 3'-1 1/4" 3'-1 1/2" 4'-1 1/2" 4'-1 1/2" 2'-9"
FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"
HIGH AT MAIN AND UPPER LEVEL (U.N.O)
6'-5" 5'-11 1/2" 12'-6 1/2" 2'-10" 14'-1 1/2" 6'-8" 5 1/2"

12'-4 1/2" 15'-4 1/2" 21'-3"

49'-0"

UPPER LEVEL FLOOR PLAN - 'B'


1 SCALE: 1/4" = 1'-0"
©
MAIN / UPPER PLAN NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT SHOWN OR NOTED ON PLANS
ALL NON 90° ANGLES ARE 45°, U.N.O.
PROVIDE 4" MIN. DOOR JAMB CONDITION AT
PERPENDICULAR WALL OR CENTER WITHIN FRAMED
OPENING, (TYPICAL U.N.O.)
TYPICAL STAIR RAILING @ 34"-38" ABOVE THE TREAD NOSING.
Godden|Sudik
TYPICAL GUARDRAIL MIN. 36" ABOVE THE ADJACENT
A R C H I T E C T S
FINISHED FLOOR AND SHALL NOT HAVE OPENINGS WHICH SEE WHAT COULD BE
ALLOW THE PASSAGE OF A SPHERE 4 INCHES IN DIAMETER.
WINDOW AND DOOR CALLOUTS ON PLANS ARE
GENERIC/NOMINAL WIDTH CALLOUTS. ACTUAL ROUGH
OPENING PER MANUFACTURER'S SPEC'S.

COUNTERTOP:
36" H. ON BASE CABINETS, BACKSPLASH PER BUILDER.
UPPER WALL CABINETS:
12" D. CABINETS INDICATED BY DASHED LINE ON PLAN,
TYP. CABINET HEIGHTS WILL VARY PER BUILDER, U.N.O.
SINK:
PROVIDE DISPOSAL, SWITCH POWER. RE: ELECT. PLANS.
REFRIGERATOR:
COORDINATE PLUMBING FOR WATER LINE AS REQUIRED.

49'-0"
FIBER-CEMENT, FIBER-MAT REINFORCED CEMENT, GLASS MAT
1'-1 3/4" 8 1/2" 11 3/4" GYPSUM BACKERS AND FIBER-REINFORCED GYPSUM SHALL
12'-6 1/2" 5'-3 1/2" 15'-7 1/2" 4'-0" 5'-0" 3'-8 1/2" BE USED AS BACKERS FOR WALL TILE IN TUB AND SHOWER
AREAS AND WALL PANELS IN SHOWER AREAS PER R702.4.2.
BATHTUB AND SHOWER FLOORS AND WALLS ABOVE
6'-6" 6'-0 1/2" 4'-5 1/2" 3'-6" 3'-6" 4'-2" 2'-6" 2'-6" BATHTUBS WITH INSTALLED SHOWER HEADS AND IN
SHOWER COMPARTMENTS SHALL BE FINISHED WITH A
NON-ABSORBENT SURFACE. SUCH WALL SURFACES SHALL
EXTEND TO A HEIGHT OF NOT LESS THAN 6 FEET ABOVE
THE FLOOR PER R307.2.
COLUMN AT OPT. OPT. EXT. COVERED COLUMN AT OPT.
EXT. COVERED PATIO BLW. EXT. COVERED COUNTERTOP:
PATIO BLW. PATIO BLW. 30" H. ON BASE CABINETS (U.N.O.), BACKSPLASH AND
MIRROR ABOVE PER BUILDER.
A WATER CLOSET, LAVATORY OR BIDET SHALL NOT BE SET
CLOSER THAN 15 INCHES FROM ITS CENTER TO ANY SIDE
WALL, PARTITION, VANITY OR CLOSER THAN 30 INCHES
CENTER-TO-CENTER BETWEEN ADJACENT FIXTURES. THERE
SHALL BE A CLEARANCE OF NOT LESS THAN 21 INCHES IN
COLUMN AT FRONT OF A WATER CLOSET, LAVATORY OR BIDET TO ANY
ENHANCED WALL, FIXTURE OR DOOR PER R307.1, P2705.1.
ELEVATION W/ OPT.
EXT. COVERED
PATIO CLOTHES WASHER/DRYER LOCATION:

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SIDE-BY-SIDE WASHER/DRYER PLUMBING, ELECTRICAL,
AND EXHAUST SHALL BE CONFIGURED TO ALLOW FOR THE
WASHER TO BE INSTALLED AND ORIENTED ON THE LEFT
SIDE WHEN FACING THE APPLIANCES.
SHELVING OR CABINETRY PER PLAN AND BUILDER SPEC'S.
LAUNDRY SINK PER PLAN AND BUILDER SPEC'S.
DRYER VENT:
INSTALL A MOISTURE EXHAUST SYSTEM THAT VENTS TO THE
3050 SH 3050 SH 3050 SH

PHONE: 303-770-8300
4050 SL 4040 SL (T) EXTERIOR. VENT MUST BE EQUIPPED WITH A BACKDRAFT
DAMPER PER G2439.3. THE MAXIMUM LENGTH OF THE
EXHAUST DUCT SHALL BE 35' FROM THE CONNECTION TO

2'-0"
THE TRANSITION DUCT FROM THE DRYER TO THE OUTLET
TERMINAL. WHERE FITTINGS ARE USED, THE MAX. LENGTH

2040 SH

4'-2 1/2"
30" x 60"

4'-3"

4'-3"
TUB/SHOWER 60" x 42" OF THE EXHAUST DUCT SHALL BE REDUCED IN
BEDROOM 4 PRIMARY TUB ACCORDANCE WITH TABLE G2439.7.4.1.

6'-3 1/2"
SUITE 4842

6'-6"
80 CLG. CLOTHES WASHER PAN AND FLOOR DRAIN:
SHOWER FLOOR DRAIN INSTALLATION AND LOCATION TO COMPLY
80 CLG. WITH P2719.1.
TEMP.

10'-0"
GLAZING BUILDER TO FIELD VERIFY FLOOR DRAIN LOCATION WITH
36" H.

2468
FLOOR FRAMING LAYOUT. ADJUST FRAMING AS REQUIRED

3'-8 1/2"
12'-5 1/2" KNEEWALL

2040 SH
PRIOR TO FLOOR DRAIN INSTALLATION.
PRIMARY

5'-4 1/2"
PROVIDE AN APPROVED PAN UNDER WASHER AND

5'-9 1/2"
10'-5 1/2"
BATH 2468 COORDINATE FLOOR DRAIN LOCATION WITH THE PAN
OPT. "TYPE" PER BUILDER SPEC'S.

3'-8 1/2"
80 CLG.

16'-0"
LAVATORY
LOCATE WASHER GRAY BOX AS REQUIRED PER CODE.

2'-0 1/2"
BATH 2

5'-6 1/2"
STACKED CLOTHES WASHER/DRYER UNITS:
80 CLG. (4) 16" SH. ACCESS, PLUMBING, ELECTRICAL AND EXHAUST, SIMILAR IN
APPLICATION AND CODE COMPLIANCE.

2468
R&S

3'-1"
5 1/2" 2468 FURNACE AND HOT WATER HEATER:

9 1/2"
3'-6" 11'-7" FINAL LOCATION PER MECHANICAL CONTRACTOR, PER G2406
5068 BP
UNIT TYPES PER BUILDER SPEC'S AND ENERGY REPORT.
PROVIDE CLOSED COMBUSTION AIR, PER M1701 & CHAPTER 24
2'-4 1/2"

6'-0"

7'-6 1/2"
ACCESS
24
THE PRESSURE RELIEF VALVE FOR THE WATER HEATER

R&S
22 x 30
ATTIC
68
4'-1 1/2"
MUST DISCHARGE TO AN APPROVED RECEPTOR, TYPICALLY

2668
R&S A FLOOR DRAIN, PER M2002.4 AND P2804.
5'-0 1/2"

2'-6"
WATER HEATER, PER M2005. WHEN THE WATER HEATER IS
30'-9"

30'-9"
(4) 16" SH.
2668 LOCATED ON A STRUCTURAL FLOOR, AN APPROVED DRAIN
R&S W.I.C.

12'-1"
2'-8"

PAN MUST ALSO BE PROVIDED, PER P2801.6 THE PAN MUST


33'-0"

33'-0"
80 CLG. BE AT LEAST 1.5" IN DEPTH, PER P2801.6.1 AND DRAIN, PER

3'-9 1/2"

LANDING
HALL P2801.6.2.

2040 SH
4'-0"
LANDING
2668
80 CLG.

3'-11"

3'-9"
4'-0"
3'-9"
5068 BP
R & S:
2040 SH

8'-11 1/2" 3'-10 1/2" 12'-1" 2'-8" 6'-5" 4'-1" 3'-9 1/2" 7'-1 1/2"
INDICATES ROD & SHELF IN CLOSETS, "(2) R & S"

4'-6 1/2"
1'-6 1/2"

INDICATES (1) HIGH ROD AND (1) LOW ROD PLUS SHELF.

R&S
SHELVES ARE 12" DEEP, U.N.O.

KNEE WALL w/ CAP


- OPT. OPEN RAIL
FIREPLACE:

9'-11"
2668
GAS FIREPLACE (PER BUILDER) W/ DIRECT VENT OR B-VENT

7 T @ 10" = 5'-10"
(4) 16" SH.
R&S PER PLANS. INSTALL PER MANUFACTURER'S INSTRUCTIONS.

HANDRAIL
6'-1 1/2"
68
REFER TO INTERIOR ELEVATIONS FOR DIMENSIONS AND

4'-0"
24
DESIGN LAYOUT. MANUFACTURER'S INSTALLATION

5'-7"
INSTRUCTIONS FOR ALL FIREPLACES MUST BE KEPT ON SITE
BEDROOM 2 FOR VERIFICATION AND INSPECTION OF REQUIRED
13'-3"

80 CLG. CLEARANCES TO COMBUSTIBLE MATERIAL. ALL FIREPLACES


11'-8 1/2"

(W) (D) TO BE UL LISTED & PROVIDED WITH A READY ACCESSIBLE


10'-10"

SHUT-OFF VALVE PER THE (IFGC) INTERNATIONAL FUEL GAS


STD. SHELF CODE SEC. 409.5.

16R
DN
ABOVE W/D

8'-8"
ATTIC ACCESS:
DR. OPT. UPPER THE ROUGHED-FRAMED OPENING SHALL NOT BE LESS

6'-10"
BEDROOM 3 LAUNDRY
CABS. THAN 22"x30" AND SHALL BE LOCATED IN A HALLWAY OR
OTHER READILY ACCESSIBLE LOCATION PER R807.1.

4'-8"
80 CLG.

R&S

4'-10"
5068 BP
80 CLG. APPLIANCES IN ATTIC REQUIREMENTS PER M1305.1.2.
AIR BARRIER SEAL AND INSULATION PER N1102.2.4.

2868
DWELLING-GARAGE OPENING AND PENETRATION
PROTECTION, SHALL COMPLY WITH, SECTION R302.5.
- DWELLING-GARAGE FIRE SEPARATION, SHALL COMPLY
2'-3"

2'-3"
4040 SL 2026 FX 2026 FX 2026FX WITH, TABLE R302.6. THIS PROVISION SHALL NOT APPLY TO
GARAGE WALLS THAT ARE PERPENDICULAR TO THE
ADJACENT DWELLING UNIT WALL PER R302.6.
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE GARAGE SIDE FROM THE RESIDENCE AND
5050 SL
ATTICS.
- NOT LESS THAN 5/8" TYPE 'X' GYPSUM BOARD OR EQUIV.
SHALL BE APPLIED TO THE GARAGE CEILING ADJACENT TO
HABITABLE ROOMS ABOVE THE GARAGE.
- NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. SHALL BE
APPLIED TO THE STRUCTURE(S) SUPPORTING FLOOR AND
CEILING ASSEMBLIES.
ROOF BLW. - NOT LESS THAN 1/2" GYPSUM BOARD OR EQUIV. APPLIED
TO THE INTERIOR SIDE OF THE EXTERIOR WALL OF A
GARAGE LOCATED LESS THAN 3'-0" FROM A DWELLING UNIT
ON THE SAME LOT.
ALL DOORS LEADING INTO GARAGES FROM LIVING SPACES
TO BE MINIMUM TIGHT FITTING, WEATHER-STRIPPED,
20-MINUTE FIRE-RATED, OR 1 3/8" THICK SOLID WOOD, OR
1 3/8" THICK SOLID OR HONEYCOMB CORE STEEL DOORS
EQUIPPED WITH SELF-CLOSING OR AUTOMATIC-CLOSING
3 DEVICE PER R302.5.1.
A6.0 HOSE BIB:
ALL HOSE BIBBS ARE "FROSTPROOF" TYPE PER R2903.10.
HOSE BIBB BLEED PER P2903.8.5.

WALL LEGEND
2x4 (3 1/2") STUD WALL
TYPICAL INTERIOR WALL (U.N.O)

2x6 (5 1/2") STUD WALL


TYPICAL EXTERIOR WALL (U.N.O.)

7'-8" 4'-10 1/2" 3'-1 1/2" 4'-1 1/2" 4'-1 1/2" 2'-9"
FLAT SOFFIT (TYPICAL INTERIOR WALL) 8'-0"
HIGH AT MAIN AND UPPER LEVEL (U.N.O)
6'-5" 5'-11 1/2" 12'-6 1/2" 2'-10" 14'-1 1/2" 6'-8" 5 1/2"

12'-4 1/2" 15'-4 1/2" 21'-3"

49'-0"

UPPER LEVEL FLOOR PLAN - 'C'


1 SCALE: 1/4" = 1'-0"
©
ROOF PLAN NOTES
COLUMN AT OPT. SOFFIT VENT
EXT. COVERED REFER TO GENERAL NOTES FOR ADDITIONAL
PATIO INFORMATION NOT SHOWN OR NOTED ON PLANS.
ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM
FACE OF FRAME TO END OF TRUSS/RAFTER, U.N.O.
ALL TRUSSES TO BE FABRICATED AND DESIGNED
UNDER THE SUPERVISION OF A COLORADO LICENSED
STRUCTURAL ENGINEER. Godden|Sudik
PROVIDE ROOF VENTS AND/OR SOFFIT VENTS TO PROVIDE A R C H I T E C T S
OPT. ROOF 4 ATTIC VENTILATION AS REQUIRED PER R806. RE: ROOF
SEE WHAT COULD BE
(OPT. EXT. VENT CALCULATIONS, "NET FREE AREA REQUIRED".
4 IN 12 ROOF VENT
COVERED PATIO) PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR

RIDGE

EY

3 IN 12
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL

LL
4 IN 12 BE PAINTED TO MATCH ADJACENT MATERIALS.

VA
WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR
WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.
CRICKETS AND SADDLES SHALL BE INSTALLED AT THE
REQUIRED LOCATIONS, PER R903.2.2. COVERINGS SHALL BE
SOFFIT VENT
SHEET METAL OR THE SAME MATERIAL AS ROOF COVERING.
BUILDER TO COORDINATE UNDERLAYMENT APPLICATION
TYPE PER CRICKET AND SADDLE ROOF SLOPE.

HI
P
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
RESISTANT ROOF SYSTEM AND SHALL INCLUDE
WEATHER PROTECTION PER R903 AND ROOF
COVERINGS PER R905. RE: FLASHING DETAILS.
ICE BARRIER AT EAVES SHALL BE INSTALLED PER R905.1.2
AND AS REQUIRED BY LOCAL AMENDMENTS. NOT
REQUIRED FOR CLAY OR CONCRETE ROOF TILE SYSTEMS.
REFER TO 2/A4.0 ROOF COVERING APPLICATION SHALL COMPLY WITH R905.1.
FOR FIRE RATED GENERAL UNDERLAYMENT APPLICATION FOR ROOF SLOPES;
ASSEMBLIES 2:12 UP TO 3.99:12, TWO-LAYERS OR EQUIV. UNDERLAYMENT.
4:12 AND GREATER ONE-LAYER OR EQUIV. UNDERLAYMENT.
FOR SPECIFIC UNDERLAYMENT TYPES, APPLICATION AND
A ATTACHMENT, RE: TABLE R905.1.1 (1-3).

UNLESS A ROOF IS SLOPED TO DRAIN OVER ROOF EDGES,


DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF A
ROOF. WHERE ROOF DRAINS ARE REQUIRED, SECONDARY
ONLY USE FIRE EMERGENCY OVERFLOW DRAINS OR SCUPPERS SHALL BE
RATED ASSEMBLIES PROVIDED. OVERFLOW DRAINS SHALL DISCHARGE TO AN
WHEN LOCATION APPROVED LOCATION AND SHALL NOT BE CONNECTED TO
ENCROACHES WITHIN ROOF DRAIN LINES,PER 903.4.1.
5' OF PROP. LINE
UNLESS SHOWN ON DRAWINGS, BUILDER TO FIELD
VERIFY LOCATION OF GUTTERS, DIVERTERS,
DOWNSPOUTS AND SPLASH BLOCKS TO DIRECT
POSITIVE DRAINAGE AWAY FROM BUILDING.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


4 IN 12
A
RIDGE
ROOF VENT CALCULATIONS
VENTILATION REQUIRED: ENCLOSED ATTICS AND
ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS

PHONE: 303-770-8300
ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF

FIRE RATED ASSEMBLIES REFER TO STANDARD ROOF


RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH

2
SEPARATE SPACE BY VENTILATING OPENINGS
PLAN FOR MORE INFORMATION PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW.
NTS VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION

OPT. EXT. COVERED PATIO OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS

3
HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE
PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH
SCALE: 1/4" = 1'-0" SCREENING OR SIM. MATERIAL W/ OPENINGS HAVING A
LEAST DIMENSION OF 1/16" MIN. AND 1/4" MAX., PER R806.1.

MINIMUM AREA: THE TOTAL NET FREE VENTILATING AREA


SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE
SPACE VENTILATED EXCEPT THAT REDUCTION OF THE
SOFFIT VENT
TOTAL AREA TO 1/300 IS PERMITTED PROVIDED THAT AT
LEAST 40% AND NOT MORE THAN 50% OF THE REQUIRED
VENTILATING AREA IS PROVIDED BY VENTILATORS
LOCATED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED
NOT MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT
OF THE SPACE, MEASURED VERTICALLY. THE BALANCE OF
THE REQUIRED VENTILATION SHALL BE LOCATED IN THE
BOTTOM ONE-THIRD OF THE ATTIC SPACE, PER R806.2.

VENT AND INSULATION CLEARANCE: WHERE EAVE OR


CORNICE VENTS ARE INSTALLED, BLOCKING, BRIDGING
AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF
REFER TO 2/A4.0 AIR. A 1" MIN. AIR SPACE SHALL BE PROVIDED BETWEEN
FOR FIRE RATED THE INSULATION AND THE ROOF SHEATHING AT THE
ASSEMBLIES LOCATION OF THE VENT, PER R806.3.
UNVENTED ATTICS AND ROOF FRAMING RAFTER
A ASSEMBLIES SHALL BE PERMITTED, PER R806.5.
UNLESS NOTED IN STRUCTURAL DRAWINGS, CUT OUT
ROOF SHEATHING BETWEEN OVERFRAMED AREAS AND
OTHER INTERCONNECTED ROOF AREAS TO COMBINE
VENTILATION AREAS.
ONLY USE FIRE LIMIT ROOF VENTS TO NO MORE THAN 2 OPENINGS PER
RATED ASSEMBLIES ROOF SHEATHING PANEL WITH NO TWO OPENINGS IN
WHEN LOCATION THE SAME PANEL BETWEEN THE SAME TRUSSES.
ENCROACHES WITHIN
5' OF PROP. LINE
NET FREE AREA REQUIRED
ELEVATION STYLE 'A'

4 IN 12
TOTAL ROOF AREA = 1,709 SQ.FT. = 246,096 IN 2
REQUIRED VENTILATION:
RIDGE 246,096 / 300 = 820 IN2 NET FREE AREA
VENTILATION PROVIDED:
AT EAVE: 7 VENTS * 65 IN2 = 455 IN2 (55%)
AT ROOF: 5 VENTS * 75 IN2 = 375 IN2 (45%)

4 IN 12
ROOF VENT

ROOF 1
TOTAL ROOF AREA = 308 SQ.FT. = 44,352 IN2
REQUIRED VENTILATION:
44,352 / 300 = 148 IN2 NET FREE AREA
VENTILATION PROVIDED:
AT EAVE: 3 VENTS * 65 IN2 = 195 IN2 (57%)
AT ROOF: 2 VENTS * 75 IN2 = 150 IN2 (43%)

TOTAL ROOF AREA = 146 SQ.FT. = 21,024 IN2

VA
EY
REQUIRED VENTILATION:

LL
LL
21,024 / 150 = 140 IN2 NET FREE AREA

EY
VA
VENTILATION PROVIDED:
AT EAVE: 3 VENTS * 65 IN2 = 195 IN2 (100%)

RIDGE
ROOF (TYP.)
TOTAL ROOF AREA = 276 SQ.FT. = 39,744 IN2
REQUIRED VENTILATION:
7 IN 12 7 IN 12
39,744 / 300 = 133 IN2 NET FREE AREA
VENTILATION PROVIDED:
AT EAVE: 3 VENTS * 65 IN2 = 195 IN2 (57%)
AT ROOF: 2 VENTS * 75 IN2 = 150 IN2 (43%)

ROOF BLW.
4 IN 12

ROOF 3

4 IN 12

EY
LL
VA

RIDGE
ROOF 2
7 IN 12 7 IN 12

COLUMN
BLW.
1
A6.0
TYPICAL OVERHANG = 1'-0" U.N.O.
TYPICAL COMPOSITION ROOF

FRAME WALL

ROOF PLAN - 'A' BLW.

1 SCALE: 1/4" = 1'-0" 1'-0" O.H.


(TYP.) ©
ROOF PLAN NOTES
COLUMN AT OPT. SOFFIT VENT
EXT. COVERED REFER TO GENERAL NOTES FOR ADDITIONAL
PATIO INFORMATION NOT SHOWN OR NOTED ON PLANS.
ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM
FACE OF FRAME TO END OF TRUSS/RAFTER, U.N.O.
ALL TRUSSES TO BE FABRICATED AND DESIGNED
UNDER THE SUPERVISION OF A COLORADO LICENSED
STRUCTURAL ENGINEER. Godden|Sudik
PROVIDE ROOF VENTS AND/OR SOFFIT VENTS TO PROVIDE A R C H I T E C T S
OPT. ROOF 4 ATTIC VENTILATION AS REQUIRED PER R806. RE: ROOF
SEE WHAT COULD BE
(OPT. EXT. VENT CALCULATIONS, "NET FREE AREA REQUIRED".
4 IN 12 ROOF VENT
COVERED PATIO) PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR

RIDGE

EY

3 IN 12
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL

LL
4 IN 12 BE PAINTED TO MATCH ADJACENT MATERIALS.

VA
WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR
WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.
CRICKETS AND SADDLES SHALL BE INSTALLED AT THE
REQUIRED LOCATIONS, PER R903.2.2. COVERINGS SHALL BE
SHEET METAL OR THE SAME MATERIAL AS ROOF COVERING.
BUILDER TO COORDINATE UNDERLAYMENT APPLICATION
TYPE PER CRICKET AND SADDLE ROOF SLOPE.

HI
P
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
REFER TO 2/A4.0 RESISTANT ROOF SYSTEM AND SHALL INCLUDE
FOR FIRE RATED WEATHER PROTECTION PER R903 AND ROOF
ASSEMBLIES COVERINGS PER R905. RE: FLASHING DETAILS.
ICE BARRIER AT EAVES SHALL BE INSTALLED PER R905.1.2
AND AS REQUIRED BY LOCAL AMENDMENTS. NOT
A REQUIRED FOR CLAY OR CONCRETE ROOF TILE SYSTEMS.
ROOF COVERING APPLICATION SHALL COMPLY WITH R905.1.
GENERAL UNDERLAYMENT APPLICATION FOR ROOF SLOPES;
2:12 UP TO 3.99:12, TWO-LAYERS OR EQUIV. UNDERLAYMENT.
4:12 AND GREATER ONE-LAYER OR EQUIV. UNDERLAYMENT.
ONLY USE FIRE
FOR SPECIFIC UNDERLAYMENT TYPES, APPLICATION AND
RATED ASSEMBLIES
ATTACHMENT, RE: TABLE R905.1.1 (1-3).
WHEN LOCATION
ENCROACHES WITHIN
5' OF PROP. LINE UNLESS A ROOF IS SLOPED TO DRAIN OVER ROOF EDGES,
DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF A
ROOF. WHERE ROOF DRAINS ARE REQUIRED, SECONDARY
EMERGENCY OVERFLOW DRAINS OR SCUPPERS SHALL BE
PROVIDED. OVERFLOW DRAINS SHALL DISCHARGE TO AN
APPROVED LOCATION AND SHALL NOT BE CONNECTED TO
ROOF DRAIN LINES,PER 903.4.1.
UNLESS SHOWN ON DRAWINGS, BUILDER TO FIELD
VERIFY LOCATION OF GUTTERS, DIVERTERS,

H
IP
DOWNSPOUTS AND SPLASH BLOCKS TO DIRECT

IP
POSITIVE DRAINAGE AWAY FROM BUILDING.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


H
4 IN 12
A
RIDGE
4 IN 12 4 IN 12
ROOF VENT CALCULATIONS
VENTILATION REQUIRED: ENCLOSED ATTICS AND
ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS

PHONE: 303-770-8300
ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF

FIRE RATED ASSEMBLIES REFER TO STANDARD ROOF


RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH

2
SEPARATE SPACE BY VENTILATING OPENINGS
PLAN FOR MORE INFORMATION PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW.
NTS VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION

OPT. EXT. COVERED PATIO OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS

3
HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE
PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH
SCALE: 1/4" = 1'-0" SCREENING OR SIM. MATERIAL W/ OPENINGS HAVING A
LEAST DIMENSION OF 1/16" MIN. AND 1/4" MAX., PER R806.1.

MINIMUM AREA: THE TOTAL NET FREE VENTILATING AREA


SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE
SPACE VENTILATED EXCEPT THAT REDUCTION OF THE
SOFFIT VENT TOTAL AREA TO 1/300 IS PERMITTED PROVIDED THAT AT
LEAST 40% AND NOT MORE THAN 50% OF THE REQUIRED
VENTILATING AREA IS PROVIDED BY VENTILATORS
LOCATED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED
REFER TO 2/A4.0 NOT MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT
FOR FIRE RATED OF THE SPACE, MEASURED VERTICALLY. THE BALANCE OF
ASSEMBLIES THE REQUIRED VENTILATION SHALL BE LOCATED IN THE
BOTTOM ONE-THIRD OF THE ATTIC SPACE, PER R806.2.

VENT AND INSULATION CLEARANCE: WHERE EAVE OR


A CORNICE VENTS ARE INSTALLED, BLOCKING, BRIDGING
AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF
AIR. A 1" MIN. AIR SPACE SHALL BE PROVIDED BETWEEN
THE INSULATION AND THE ROOF SHEATHING AT THE
LOCATION OF THE VENT, PER R806.3.
ONLY USE FIRE UNVENTED ATTICS AND ROOF FRAMING RAFTER
RATED ASSEMBLIES ASSEMBLIES SHALL BE PERMITTED, PER R806.5.
WHEN LOCATION
ENCROACHES WITHIN UNLESS NOTED IN STRUCTURAL DRAWINGS, CUT OUT
5' OF PROP. LINE ROOF SHEATHING BETWEEN OVERFRAMED AREAS AND
OTHER INTERCONNECTED ROOF AREAS TO COMBINE
VENTILATION AREAS.
LIMIT ROOF VENTS TO NO MORE THAN 2 OPENINGS PER
ROOF SHEATHING PANEL WITH NO TWO OPENINGS IN
THE SAME PANEL BETWEEN THE SAME TRUSSES.

NET FREE AREA REQUIRED


H
IP
ELEVATION STYLE 'B'

IP
H
4 IN 12
TOTAL ROOF AREA = 1,709 SQ.FT. = 246,096 IN 2
REQUIRED VENTILATION:
RIDGE 246,096 / 300 = 820 IN2 NET FREE AREA
10'-0"

10'-0"
4 IN 12 4 IN 12 VENTILATION PROVIDED:
AT EAVE: 7 VENTS * 65 IN2 = 455 IN2 (55%)
AT ROOF: 5 VENTS * 75 IN2 = 375 IN2 (45%)

4 IN 12
ROOF VENT
ROOF 1
IP

H
TOTAL ROOF AREA = 308 SQ.FT. = 44,352 IN2
H

IP
REQUIRED VENTILATION:
44,352 / 300 = 148 IN2 NET FREE AREA
VENTILATION PROVIDED:
AT EAVE: 3 VENTS * 65 IN2 = 195 IN2 (57%)
AT ROOF: 2 VENTS * 75 IN2 = 150 IN2 (43%)

5'-0" 5'-0"
TOTAL ROOF AREA = 146 SQ.FT. = 21,024 IN2
REQUIRED VENTILATION:
21,024 / 150 = 140 IN2 NET FREE AREA
VENTILATION PROVIDED:
AT LOW ROOF: 2 VENTS * 75 IN2 = 150 IN2 (100%)

VA
ROOF (TYP.) EY

LL
LL
TOTAL ROOF AREA = 276 SQ.FT. = 39,744 IN2

EY
VA

REQUIRED VENTILATION:
39,744 / 300 = 133 IN2 NET FREE AREA

RIDGE
VENTILATION PROVIDED:
AT EAVE: 3 VENTS * 65 IN2 = 195 IN2 (57%)
IF SOFFIT IS REQUIRED TO BE AT ROOF: 2 VENTS * 75 IN2 = 150 IN2 (43%)
RATED REPLACE SOFFIT VENT 4 IN 12 4 IN 12
WITH LOW-PROFILE ROOF VENT
(TYP.)

4 IN 12
ROOF BLW.
4 IN 12 4 IN 12
RIDGE

EY
LL
ROOF 3

VA
4 IN 12 4 IN 12

ROOF 2

RIDGE
COLUMN
BLW.
2
A6.0
TYPICAL OVERHANG = 1'-0" U.N.O.
TYPICAL COMPOSITION ROOF

FRAME WALL

ROOF PLAN - 'B' (TYP.)

1 SCALE: 1/4" = 1'-0" 1'-0" O.H.


(TYP.) ©
ROOF PLAN NOTES
COLUMN AT OPT. SOFFIT VENT
EXT. COVERED REFER TO GENERAL NOTES FOR ADDITIONAL
PATIO INFORMATION NOT SHOWN OR NOTED ON PLANS.
ALL OVERHANGS ARE MEASURED HORIZONTALLY FROM
FACE OF FRAME TO END OF TRUSS/RAFTER, U.N.O.
ALL TRUSSES TO BE FABRICATED AND DESIGNED
UNDER THE SUPERVISION OF A COLORADO LICENSED
STRUCTURAL ENGINEER. Godden|Sudik
PROVIDE ROOF VENTS AND/OR SOFFIT VENTS TO PROVIDE A R C H I T E C T S
OPT. ROOF 4 ATTIC VENTILATION AS REQUIRED PER R806. RE: ROOF
SEE WHAT COULD BE
(OPT. EXT. VENT CALCULATIONS, "NET FREE AREA REQUIRED".
4 IN 12 ROOF VENT
COVERED PATIO) PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR

RIDGE

EY

3 IN 12
COLUMN AT CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL

LL
ENHANCED 4 IN 12 BE PAINTED TO MATCH ADJACENT MATERIALS.

VA
ELEVATION W/ WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR
OPT. EXT. WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
COVERED P2607.
PATIO
CRICKETS AND SADDLES SHALL BE INSTALLED AT THE
REQUIRED LOCATIONS, PER R903.2.2. COVERINGS SHALL BE
SHEET METAL OR THE SAME MATERIAL AS ROOF COVERING.
BUILDER TO COORDINATE UNDERLAYMENT APPLICATION
TYPE PER CRICKET AND SADDLE ROOF SLOPE.

HI
P
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
RESISTANT ROOF SYSTEM AND SHALL INCLUDE
WEATHER PROTECTION PER R903 AND ROOF

HIP

HIP
COVERINGS PER R905. RE: FLASHING DETAILS.
ICE BARRIER AT EAVES SHALL BE INSTALLED PER R905.1.2
AND AS REQUIRED BY LOCAL AMENDMENTS. NOT
REQUIRED FOR CLAY OR CONCRETE ROOF TILE SYSTEMS.
REFER TO 2/A4.0 ROOF COVERING APPLICATION SHALL COMPLY WITH R905.1.
FOR FIRE RATED GENERAL UNDERLAYMENT APPLICATION FOR ROOF SLOPES;
ASSEMBLIES 2:12 UP TO 3.99:12, TWO-LAYERS OR EQUIV. UNDERLAYMENT.
4:12 AND GREATER ONE-LAYER OR EQUIV. UNDERLAYMENT.
FOR SPECIFIC UNDERLAYMENT TYPES, APPLICATION AND
A ATTACHMENT, RE: TABLE R905.1.1 (1-3).

UNLESS A ROOF IS SLOPED TO DRAIN OVER ROOF EDGES,


DRAINS SHALL BE INSTALLED AT EACH LOW POINT OF A
ROOF. WHERE ROOF DRAINS ARE REQUIRED, SECONDARY
ONLY USE FIRE EMERGENCY OVERFLOW DRAINS OR SCUPPERS SHALL BE
RATED ASSEMBLIES PROVIDED. OVERFLOW DRAINS SHALL DISCHARGE TO AN
WHEN LOCATION APPROVED LOCATION AND SHALL NOT BE CONNECTED TO
ENCROACHES WITHIN ROOF DRAIN LINES,PER 903.4.1.
5' OF PROP. LINE
UNLESS SHOWN ON DRAWINGS, BUILDER TO FIELD
VERIFY LOCATION OF GUTTERS, DIVERTERS,
DOWNSPOUTS AND SPLASH BLOCKS TO DIRECT
POSITIVE DRAINAGE AWAY FROM BUILDING.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


4 IN 12
A
RIDGE

7 IN 12 7 IN 12
ROOF VENT CALCULATIONS
VENTILATION REQUIRED: ENCLOSED ATTICS AND
ENCLOSED RAFTER SPACES FORMED WHERE CEILINGS

PHONE: 303-770-8300
ARE APPLIED DIRECTLY TO THE UNDERSIDE OF ROOF

FIRE RATED ASSEMBLIES REFER TO STANDARD ROOF


RAFTERS SHALL HAVE CROSS VENTILATION FOR EACH

2
SEPARATE SPACE BY VENTILATING OPENINGS
PLAN FOR MORE INFORMATION PROTECTED AGAINST THE ENTRANCE OF RAIN OR SNOW.
NTS VENTILATION OPENINGS SHALL HAVE A LEAST DIMENSION

OPT. EXT. COVERED PATIO OF 1/16" MIN. AND 1/4" MAX. VENTILATION OPENINGS

3
HAVING A LEAST DIMENSION LARGER THAN 1/4" SHALL BE
PROVIDED WITH CORROSION-RESISTANT WIRE CLOTH
SCALE: 1/4" = 1'-0" SCREENING OR SIM. MATERIAL W/ OPENINGS HAVING A
LEAST DIMENSION OF 1/16" MIN. AND 1/4" MAX., PER R806.1.

MINIMUM AREA: THE TOTAL NET FREE VENTILATING AREA


SHALL NOT BE LESS THAN 1/150 OF THE AREA OF THE
SPACE VENTILATED EXCEPT THAT REDUCTION OF THE
SOFFIT VENT TOTAL AREA TO 1/300 IS PERMITTED PROVIDED THAT AT
LEAST 40% AND NOT MORE THAN 50% OF THE REQUIRED
VENTILATING AREA IS PROVIDED BY VENTILATORS
LOCATED IN THE UPPER PORTION OF THE ATTIC OR
RAFTER SPACE. UPPER VENTILATORS SHALL BE LOCATED
NOT MORE THAN 3' BELOW THE RIDGE OR HIGHEST POINT
OF THE SPACE, MEASURED VERTICALLY. THE BALANCE OF
THE REQUIRED VENTILATION SHALL BE LOCATED IN THE

HIP

HIP
BOTTOM ONE-THIRD OF THE ATTIC SPACE, PER R806.2.

VENT AND INSULATION CLEARANCE: WHERE EAVE OR


CORNICE VENTS ARE INSTALLED, BLOCKING, BRIDGING
AND INSULATION SHALL NOT BLOCK THE FREE FLOW OF
REFER TO 2/A4.0 AIR. A 1" MIN. AIR SPACE SHALL BE PROVIDED BETWEEN
FOR FIRE RATED THE INSULATION AND THE ROOF SHEATHING AT THE
ASSEMBLIES LOCATION OF THE VENT, PER R806.3.
UNVENTED ATTICS AND ROOF FRAMING RAFTER
A ASSEMBLIES SHALL BE PERMITTED, PER R806.5.
UNLESS NOTED IN STRUCTURAL DRAWINGS, CUT OUT
ROOF SHEATHING BETWEEN OVERFRAMED AREAS AND
OTHER INTERCONNECTED ROOF AREAS TO COMBINE
VENTILATION AREAS.
ONLY USE FIRE LIMIT ROOF VENTS TO NO MORE THAN 2 OPENINGS PER
RATED ASSEMBLIES ROOF SHEATHING PANEL WITH NO TWO OPENINGS IN
WHEN LOCATION THE SAME PANEL BETWEEN THE SAME TRUSSES.
ENCROACHES WITHIN
5' OF PROP. LINE
NET FREE AREA REQUIRED
ELEVATION STYLE 'C'

4 IN 12
TOTAL ROOF AREA = 1,709 SQ.FT. = 246,096 IN 2
REQUIRED VENTILATION:
RIDGE 246,096 / 300 = 820 IN2 NET FREE AREA
VENTILATION PROVIDED:
7 IN 12 AT EAVE: 7 VENTS * 65 IN2 = 455 IN2 (55%)
7 IN 12
AT ROOF: 5 VENTS * 75 IN2 = 375 IN2 (45%)

4 IN 12
ROOF VENT
ROOF 1
TOTAL ROOF AREA = 308 SQ.FT. = 44,352 IN2
REQUIRED VENTILATION:
44,352 / 300 = 148 IN2 NET FREE AREA
VENTILATION PROVIDED:
AT EAVE: 3 VENTS * 65 IN2 = 195 IN2 (57%)
AT ROOF: 2 VENTS * 75 IN2 = 150 IN2 (43%)

TOTAL ROOF AREA = 146 SQ.FT. = 21,024 IN2

VA
EY
REQUIRED VENTILATION:

LL

LL
21,024 / 150 = 140 IN2 NET FREE AREA

EY
VA
VENTILATION PROVIDED:
2'-0" 2'-0" AT LOW ROOF: 2 VENTS * 75 IN2 = 150 IN2 (100%)

RIDGE
ROOF (TYP.)
TOTAL ROOF AREA = 276 SQ.FT. = 39,744 IN2
REQUIRED VENTILATION:
39,744 / 300 = 133 IN2 NET FREE AREA

HIP
HIP

VENTILATION PROVIDED:
7 IN 12 7 IN 12 AT EAVE: 3 VENTS * 65 IN2 = 195 IN2 (57%)
IF SOFFIT IS REQUIRED TO BE AT ROOF: 2 VENTS * 75 IN2 = 150 IN2 (43%)
RATED REPLACE SOFFIT VENT
WITH LOW-PROFILE ROOF VENT
(TYP.)

ROOF BLW.

4 IN 12

EY
LL
RIDGE

VA
4 IN 12 4 IN 12 ROOF 3

7 IN 12 7 IN 12

ROOF 2

RIDGE
COLUMN
BLW.
3
A6.0
TYPICAL OVERHANG = 1'-0" U.N.O.
TYPICAL COMPOSITION ROOF

FRAME WALL

ROOF PLAN - 'C' (TYP.)

1 SCALE: 1/4" = 1'-0" 1'-0" O.H.


(TYP.) ©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
GABLE VENT ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
RE: DETAIL PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

5/4 x 8 FASCIA UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


W/ 5/4 x 2 4 IN 12 ASPHALT SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
SHINGLE STOP SHINGLE ROOF (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR

2'-6"
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
12 VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
7
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

1'-3"
HEEL AT 7 IN 12 5/4 x 8 FASCIA W/
METAL GUTTERS
UPPER PLATE

WINDOW HEAD TEXTURED PANEL


BOARD W/ 5/4 x 2
BATTEN AT 16" O.C.
T.O. TRIM

8'-1 1/8"
5/4 x 8 TRIM
9"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


WINDOW TRIM 5/4 x 4
RETURN

7'-0"
RE: DETAIL CORNER TRIM

5'-4"
8" LAP SIDING 4 IN 12
12
1'-0 5/8"

1'-3"
UPPER LEVEL 4 IN 12 HEEL AT 7 IN 12

PHONE: 303-770-8300
MAIN PLATE MAIN PLATE

WINDOW HEAD
9'-1 1/8"

9'-1 1/8"
8'-0"
5/4 x 4 TRIM
T.O. CAP

4" LAP SIDING

3'-0"
1'-2 1/8"

MAIN LEVEL MAIN LEVEL

T.O. FOUNDATION

PROPOSED RAISED PANEL COLUMN CONC. STOOP


FINISHED GRADE OVERHEAD DOOR RE: DETAIL
RE: DETAIL STEPS PER GRADE
WRAPPED BEAM

FRONT ELEVATION - 'A'


1 SCALE: 1/4" = 1'-0"

7 IN 12

12
4

4'-0"
RETURN

7 IN 12

1'-0"
RETURN

6'-0" RETURN
5/4 x 4 TRIM CONC. STOOP W/
STEPS PER GRADE

NON-GARAGE SIDE
REMOVE 2040 SH
WINDOW @ OPT.
BEDROOM 3 / BATH 3

ELEVATION - 'A'
2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

ASPHALT UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


SHINGLE ROOF 4 IN 12 SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
5/4 x 8 FASCIA W/
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
METAL GUTTERS
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

5/4 x 4 UPPER PLATE


CORNER TRIM
WINDOW HEAD

8" LAP SIDING

8'-1 1/8"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


7'-0"

1'-0 5/8"
WINDOW TRIM UPPER LEVEL
RE: DETAIL

PHONE: 303-770-8300
MAIN PLATE

WINDOW HEAD

9'-1 1/8"
8'-0"

1'-2 1/8"
MAIN LEVEL

T.O. FOUNDATION

CONC. STOOP W/
STEPS PER GRADE
PROPOSED
FINISHED GRADE

REAR ELEVATION - 'A'


1 SCALE: 1/4" = 1'-0"

7 IN 12

12
4
1'-0"

HEEL AT 4 IN 12

UPPER PLATE

4'-0"
RETURN
8'-1 1/8"

7 IN 12
6"
WINDOW TRIM RETURN
RE: DETAIL
12
1'-0 5/8"

4
5/4 x 10 TRIM
UPPER LEVEL
12
4

6"
MAIN PLATE
HEEL HEIGHT
WINDOW HEAD GARAGE PLATE
9'-1 1/8"

8'-1 1/8"
8'-0"

1'-2 1/4"
MAIN LEVEL MAIN LEVEL

T.O. FOUNDATION

5/4 x 4 TRIM 6'-0"


RETURN

GARAGE SIDE ELEVATION - 'A'


2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

4 IN 12 WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


5/4 x 8 FASCIA SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
W/ 5/4 x 2 (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
SHINGLE STOP BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
8" LAP SIDING ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

3 IN 12
12
4

6"
HEEL AT 4 IN 12
EXT. COVERED
PATIO PLATE 5/4 x 8 TRIM

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


9'-1 1/8"

PHONE: 303-770-8300
MAIN LEVEL

COLUMN CONC. PATIO


PROPOSED RE: DETAIL
FINISHED GRADE
OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

REAR ELEVATION - 'A'


1 SCALE: 1/4" = 1'-0"

7 IN 12

12
4

7 IN 12
1'-0" RETURN

5/4 x 8 FASCIA W/ 12 5/4 x 8 FASCIA


3
METAL GUTTERS W/ 5/4 x 2
SHINGLE STOP
4 IN 12 12 4 IN 12
3

5"
HEEL HEIGHT
EXT. COVERED PATIO PLATE
5/4 x 8 TRIM

9'-1 1/8"
CONC. PATIO

MAIN LEVEL

REFER TO STANDARD ELEVATION


FOR MORE INFORMATION
6'-0" RETURN
5/4 x 4 TRIM PROPOSED
FINISHED GRADE

OPT. EXT. COVERED PATIO OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

GARAGE SIDE ELEVATION - 'A' NON-GARAGE SIDE ELEVATION - 'A'


3 SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
GABLE VENT ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
RE: DETAIL PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

5/4 x 8 FASCIA UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


W/ 5/4 x 2 4 IN 12 ASPHALT SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
SHINGLE STOP SHINGLE ROOF (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR

2'-6"
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
12 VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
7
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

1'-3"
HEEL AT 7 IN 12 5/4 x 8 FASCIA W/
METAL GUTTERS
UPPER PLATE HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

WINDOW HEAD TEXTURED PANEL • CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
BOARD W/ 5/4 x 2 TEXTURED PANEL BOARD
BATTEN AT 16" O.C. • DECORATIVE WINDOW TRIM
T.O. TRIM • GABLE VENT DETAIL

8'-1 1/8"
5/4 x 8 TRIM
9"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


WINDOW TRIM 5/4 x 4
RETURN

7'-0"
RE: DETAIL CORNER TRIM

5'-4"
8" LAP SIDING 4 IN 12
12
1'-0 5/8"

1'-3"
UPPER LEVEL 4 IN 12 HEEL AT 7 IN 12

PHONE: 303-770-8300
MAIN PLATE MAIN PLATE

WINDOW HEAD
9'-1 1/8"

9'-1 1/8"
8'-0"
5/4 x 4 TRIM
T.O. CAP

4" LAP SIDING

3'-0"
1'-2 1/8"

MAIN LEVEL MAIN LEVEL

T.O. FOUNDATION

PROPOSED RAISED PANEL COLUMN CONC. STOOP


FINISHED GRADE OVERHEAD DOOR RE: DETAIL
RE: DETAIL STEPS PER GRADE
WRAPPED BEAM

FRONT ELEVATION - 'A'


1 SCALE: 1/4" = 1'-0"

GABLE VENT
RE: DETAIL

7 IN 12

2'-6"
12
TEXTURED PANEL 4
BOARD W/ 5/4 x 4
BATTEN AT 16" O.C.

7 IN 12

1'-0"
RETURN

6'-0" RETURN
5/4 x 4 TRIM

ENHANCED
REMOVE 2040 SH
WINDOW @ OPT.
BEDROOM 3 / BATH 3

NON-GARAGE SIDE ELEVATION - 'A' REFER TO STANDARD ELEVATION


FOR MORE INFORMATION

2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

TEXTURED PANEL
EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE
BOARD W/ 5/4 x 4
BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
BATTEN AT 16" O.C.
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

ASPHALT UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


SHINGLE ROOF 4 IN 12 SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
5/4 x 8 FASCIA W/
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
METAL GUTTERS
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

5/4 x 4 UPPER PLATE HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED
CORNER TRIM
WINDOW HEAD
• CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
TEXTURED PANEL BOARD
8" LAP SIDING
• DECORATIVE WINDOW TRIM
T.O. TRIM • GABLE VENT DETAIL

8'-1 1/8"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


7'-0"
5'-4"

1'-0 5/8"
WINDOW TRIM UPPER LEVEL
RE: DETAIL

PHONE: 303-770-8300
MAIN PLATE

WINDOW HEAD

9'-1 1/8"
8'-0"

1'-2 1/8"
MAIN LEVEL

T.O. FOUNDATION

CONC. STOOP W/
STEPS PER GRADE
PROPOSED
FINISHED GRADE
ENHANCED REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

REAR ELEVATION - 'A'


1 SCALE: 1/4" = 1'-0"

GABLE VENT
RE: DETAIL

TEXTURED PANEL
BOARD W/ 5/4 x 4
BATTEN AT 16" O.C.

7 IN 12

2'-6"
12
4

ADDITIONAL
WINDOW ADDED
@ ENHANCED
ELEVATION

7 IN 12
6"
RETURN
12
4
5/4 x 10 TRIM

12
4

5/4 x 4 TRIM 6'-0" RETURN

ENHANCED REFER TO STANDARD ELEVATION


FOR MORE INFORMATION

GARAGE SIDE ELEVATION - 'A'


2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
TEXTURED PANEL ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
BOARD W/ 5/4 x 4 SEE WHAT COULD BE
BATTEN AT 16" O.C.
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

4 IN 12 WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
TEXTURED PANEL PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.
BOARD W/ 5/4 x 4
BATTEN AT 16" O.C.
UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS
5/4 x 8 FASCIA SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
W/ 5/4 x 2 (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
SHINGLE STOP BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

3 IN 12
12
4 HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

6"
HEEL AT 4 IN 12
EXT. COVERED • CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
PATIO PLATE 5/4 x 8 TRIM TEXTURED PANEL BOARD
• DECORATIVE WINDOW TRIM
• GABLE VENT DETAIL

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


9'-1 1/8"

PHONE: 303-770-8300
MAIN LEVEL

COLUMN CONC. PATIO


PROPOSED RE: DETAIL
FINISHED GRADE
ENHANCED OPT. EXT. COVERED REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

PATIO REAR ELEVATION - 'A'


1 SCALE: 1/4" = 1'-0"

GABLE VENT
RE: DETAIL

7 IN 12

2'-6"
12
TEXTURED PANEL 4
BOARD W/ 5/4 x 4
BATTEN AT 16" O.C.

7 IN 12
1'-0" RETURN

5/4 x 8 FASCIA W/ 12 5/4 x 8 FASCIA


3
METAL GUTTERS W/ 5/4 x 2
SHINGLE STOP
4 IN 12 12 4 IN 12
3

5"
HEEL HEIGHT
EXT. COVERED PATIO PLATE
5/4 x 8 TRIM

9'-1 1/8"
CONC. PATIO

MAIN LEVEL

REFER TO STANDARD ELEVATION


FOR MORE INFORMATION
6'-0" RETURN
5/4 x 4 TRIM PROPOSED
FINISHED GRADE

ENHANCED OPT. EXT. COVERED ENHANCED OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

PATIO GARAGE SIDE ELEVATION - 'A' NON-GARAGE SIDE ELEVATION - 'A'


3 SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"

©
Godden|Sudik
A R C H I T E C T S
SEE WHAT COULD BE

2"

5/4 X 6 TRIM
2"

5/4 X 6
HEAD TRIM
SIMULATED DIVIDED
12" x 24" DECORATIVE LITES RE: ELEVATIONS
GABLE VENT FOR LOCATIONS

5/4 X 4 TRIM 5/4 X 4 TRIM


5/4 X 4
JAMB TRIM
5/4 X 4
SILL TRIM
FRONT & ENHANCED
ELEVATIONS
FRONT & ENHANCED STANDARD SIDE &
ELEVATIONS REAR ELEVATIONS

GABLE VENT DETAIL - 'A' WINDOW TRIM - 'A'

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


4 SCALE: 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0"

PHONE: 303-770-8300
8"
2"

COLUMN PER
STRUCTURAL 8" 5/4 X 6 TRIM

5/4 X 4 TRIM
PLAN
THERMA TRU
2-PANEL DOOR
(OR SIMILAR)
FRAMED
BOX COLUMN

5/4 X 4 TRIM
5/4 X 4 TRIM

FRONT PORCH
COLUMN & RAILING - 'A' FRONT DOOR - 'A'
5 SCALE: 1/2" = 1'-0" 2 SCALE: 1/2" = 1'-0"

OPT. GLAZING
6X6
CORBEL
10"
2"
6"

4"

WAYNE DALTON
(SERIES 9100)
6" 6" 4" RANCH RAISED PANEL
OVERHEAD DOOR W/
OPT. GLAZING
(OR SIMILAR)

FRONT SIDE
PROFILE PROFILE

DOOR TRIM MAY VARY -


RE: FRONT ELEVATION

CORBEL DETAIL - 'A' GARAGE DOOR - 'A'


6 SCALE: N.T.S.
3 SCALE: 1/2" = 1'-0"
©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

12 12 UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


4 4 IN 12 4 SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
4 x 4 BRACKET BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
RE: DETAIL ASPHALT VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
SHINGLE ROOF ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
12
4 MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

1'-0"
5/4 x 8 FASCIA W/
HEEL HEIGHT METAL GUTTERS

UPPER PLATE

WINDOW HEAD
SHAKE SIDING

T.O. TRIM 5/4 x 10 TRIM

8'-1 1/8"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


WINDOW TRIM

7'-0"
RE: DETAIL 8" LAP
SIDING

5'-0"
9" 4 IN 12
5/4 x 8 FASCIA
1'-0 5/8"

W/ 5/4 x 2 RETURN
SHINGLE STOP 12

1'-0"
12
4 4
UPPER LEVEL HEEL HEIGHT

PHONE: 303-770-8300
MAIN PLATE / GARAGE HEEL MAIN PLATE / B.O. TRIM

GARAGE PLATE / B.O. TRIM WINDOW HEAD

5/4 x 4
CORNER TRIM
5/4 x 4 FRIEZE
9'-1 1/8"

9'-1 1/8"
5/4 x 6 TRIM
8'-1 1/8"

8'-0"
T.O. CAP

4" LAP SIDING

3'-0"
1'-2 1/8"

MAIN LEVEL MAIN LEVEL

T.O. FOUNDATION

PROPOSED RAISED PANEL COLUMN CONC. PORCH


FINISHED GRADE OVERHEAD DOOR RE: DETAIL
RE: DETAIL STEPS PER GRADE
WRAPPED BEAM

FRONT ELEVATION - 'B'


1 SCALE: 1/4" = 1'-0"

4 IN 12
5/4 x 4 FRIEZE 12
4

4 IN 12

4'-0"
RETURN

1'-0"
4 IN 12 RETURN

6'-0" RETURN
5/4 x 4 TRIM

NON-GARAGE SIDE
REMOVE 2040 SH
WINDOW @ OPT.
BEDROOM 3 / BATH 3

ELEVATION - 'B'
2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

ASPHALT UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


SHINGLE ROOF 4 IN 12
SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
5/4 x 8 FASCIA W/
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
METAL GUTTERS
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

5/4 x 4 UPPER PLATE


CORNER TRIM
WINDOW HEAD

8" LAP SIDING

8'-1 1/8"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


7'-0"
WINDOW TRIM

1'-0 5/8"
RE: DETAIL

UPPER LEVEL

PHONE: 303-770-8300
MAIN PLATE

WINDOW HEAD

9'-1 1/8"
8'-0"

1'-2 1/8"
MAIN LEVEL

T.O. FOUNDATION

CONC. STOOP W/
STEPS PER GRADE
PROPOSED
FINISHED GRADE

REAR ELEVATION - 'B'


1 SCALE: 1/4" = 1'-0"

5/4 x 4 FRIEZE
4 IN 12
12
4

4 IN 12
1'-0"

HEEL HEIGHT

UPPER PLATE

4'-0"
RETURN
8'-1 1/8"

4 IN 12 4 IN 12
1'-0 5/8"

1'-0"
RETURN 5/4 x 10 TRIM
UPPER LEVEL

MAIN PLATE

WINDOW HEAD
9'-1 1/8"

8'-0"

MAIN LEVEL

5/4 x 4 TRIM 6'-0" RETURN

GARAGE SIDE ELEVATION - 'B'


2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.
4 IN 12
WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR
WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

5/4 x 8 FASCIA
W/ 5/4 x 2 UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS
SHINGLE STOP SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
5/4 x 4 FRIEZE (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
8" LAP BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
SIDING VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

3 IN 12
12
4

6"
HEEL AT 4 IN 12
EXT. COVERED
PATIO PLATE 5/4 x 8 TRIM

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


9'-1 1/8"

PHONE: 303-770-8300
MAIN LEVEL

COLUMN CONC. PATIO


PROPOSED RE: DETAIL
FINISHED GRADE
OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

REAR ELEVATION - 'B'


1 SCALE: 1/4" = 1'-0"

4 IN 12
12
4

4 IN 12

4'-0"
RETURN

1'-0" RETURN

5/4 x 8 FASCIA W/ 12 1'-0" 5/4 x 8 FASCIA


3 4 IN 12 RETURN
METAL GUTTERS W/ 5/4 x 2
SHINGLE STOP
4 IN 12 12 4 IN 12
3

5"
HEEL HEIGHT
EXT. COVERED PATIO PLATE

9'-1 1/8"
CONC. PATIO

MAIN LEVEL

REFER TO STANDARD ELEVATION


FOR MORE INFORMATION
6'-0" RETURN
5/4 x 4 TRIM PROPOSED
FINISHED GRADE

OPT. EXT. COVERED PATIO OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

GARAGE SIDE ELEVATION - 'B' NON-GARAGE SIDE ELEVATION - 'B'


3 SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

12 12 UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


4 4 IN 12 4 SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
4 x 4 BRACKET BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
RE: DETAIL ASPHALT VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
SHINGLE ROOF ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
12
4 MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

1'-0"
5/4 x 8 FASCIA W/
HEEL HEIGHT METAL GUTTERS

UPPER PLATE HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

WINDOW HEAD
SHAKE SIDING • CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
SHAKE SIDING
• DECORATIVE WINDOW TRIM
5/4 x 10 TRIM • BRACKET DETAIL
T.O. TRIM • DECORATIVE COLUMN

8'-1 1/8"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


WINDOW TRIM

7'-0"
RE: DETAIL 8" LAP
SIDING

5'-0"
9" 4 IN 12
5/4 x 8 FASCIA
1'-0 5/8"

W/ 5/4 x 2 RETURN
SHINGLE STOP 12

1'-0"
12
4 4
UPPER LEVEL HEEL HEIGHT

PHONE: 303-770-8300
MAIN PLATE / GARAGE HEEL MAIN PLATE / B.O. TRIM

GARAGE PLATE / B.O. TRIM WINDOW HEAD

5/4 x 4
CORNER TRIM
5/4 x 4 FRIEZE
9'-1 1/8"

9'-1 1/8"
5/4 x 6 TRIM
8'-1 1/8"

8'-0"
T.O. CAP

4" LAP SIDING

3'-0"
1'-2 1/8"

MAIN LEVEL MAIN LEVEL

T.O. FOUNDATION

PROPOSED RAISED PANEL COLUMN CONC. PORCH


FINISHED GRADE OVERHEAD DOOR RE: DETAIL
RE: DETAIL STEPS PER GRADE
WRAPPED BEAM

FRONT ELEVATION - 'B'


1 SCALE: 1/4" = 1'-0"

4 IN 12
4 x 4 BRACKET SHAKE SIDING
5/4 x 4 FRIEZE 12 RE: DETAIL
4

4 IN 12

1'-0"
4 IN 12 RETURN

6'-0" RETURN
5/4 x 4 TRIM

ENHANCED
REMOVE 2040 SH
WINDOW @ OPT.
BEDROOM 3 / BATH 3

NON-GARAGE SIDE ELEVATION - 'B'


2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
SHAKE SIDING PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

ASPHALT UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


SHINGLE ROOF 4 IN 12
SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
5/4 x 8 FASCIA W/
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
METAL GUTTERS
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

UPPER PLATE HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

WINDOW HEAD
• CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
SHAKE SIDING
5/4 x 10 TRIM
• DECORATIVE WINDOW TRIM
• BRACKET DETAIL
T.O. TRIM • DECORATIVE COLUMN
5/4 x 4

8'-1 1/8"
CORNER TRIM

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


7'-0"
5'-0"
8" LAP SIDING

1'-0 5/8"
UPPER LEVEL
WINDOW TRIM

PHONE: 303-770-8300
RE: DETAIL MAIN PLATE

WINDOW HEAD

9'-1 1/8"
8'-0"

1'-2 1/8"
MAIN LEVEL

T.O. FOUNDATION

CONC. STOOP W/
STEPS PER GRADE
PROPOSED
FINISHED GRADE
ENHANCED
REAR ELEVATION - 'B'
1 SCALE: 1/4" = 1'-0"

4 x 4 BRACKET
RE: DETAIL

5/4 x 4 FRIEZE
4 IN 12
SHAKE SIDING
12
4

4 IN 12

ADDITIONAL
WINDOW ADDED
@ ENHANCED
ELEVATION

4 IN 12 4 IN 12
1'-0"
RETURN 5/4 x 10 TRIM

5/4 x 4 TRIM 6'-0" RETURN

ENHANCED
GARAGE SIDE ELEVATION - 'B'
2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
SHAKE SIDING ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.
4 IN 12
WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR
WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
4 x 4 BRACKET ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
RE: DETAIL PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.
5/4 x 8 FASCIA
W/ 5/4 x 2
SHINGLE STOP UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS
SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
5/4 x 4 FRIEZE (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

3 IN 12
12
4 HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

6"
HEEL AT 4 IN 12
EXT. COVERED • CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
PATIO PLATE 5/4 x 8 TRIM SHAKE SIDING
• DECORATIVE WINDOW TRIM
• BRACKET DETAIL
• DECORATIVE COLUMN

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


9'-1 1/8"

PHONE: 303-770-8300
MAIN LEVEL

COLUMN CONC. PATIO SHAKE SIDING


PROPOSED RE: DETAIL

ENHANCED OPT. EXT. COVERED


FINISHED GRADE REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

PATIO REAR ELEVATION - 'B'


1 SCALE: 1/4" = 1'-0"

4 IN 12
12
4

4 IN 12

SHAKE SIDING

1'-0" RETURN

5/4 x 8 FASCIA W/ 12 1'-0"


3 5/4 x 8 FASCIA
METAL GUTTERS 4 IN 12 RETURN W/ 5/4 x 2
4 IN 12 SHINGLE STOP
12 4 IN 12
3

5"
HEEL HEIGHT
EXT. COVERED PATIO PLATE

9'-1 1/8"
CONC. PATIO

MAIN LEVEL

REFER TO STANDARD ELEVATION


FOR MORE INFORMATION
6'-0" RETURN
5/4 x 4 TRIM PROPOSED

ENHANCED OPT. EXT. COVERED ENHANCED OPT. EXT. COVERED PATIO


FINISHED GRADE
REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

PATIO GARAGE SIDE ELEVATION - 'B' NON-GARAGE SIDE ELEVATION - 'B'


3 SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"

©
Godden|Sudik
A R C H I T E C T S
SEE WHAT COULD BE

4X4
BRACKET
5/4 X 8 BACK
BOARD 5/4 X 6
4X4 HEAD TRIM
BRACKET 5/4 X 4
FRIEZE SIMULATED DIVIDED
5/4 X 8 BACK BOARD LITES RE: ELEVATIONS
FOR LOCATIONS

2'-6"
EXTERIOR MATERIAL -
RE: ELEVATIONS
5/4 X 4 5/4 X 4

2"
JAMB TRIM JAMB TRIM
1'-0"
5/4 X 6
SILL TRIM
SIDE FRONT FRONT & ENHANCED STANDARD SIDE &
PROFILE PROFILE ELEVATIONS REAR ELEVATIONS

BRACKET DETAIL - 'B' WINDOW TRIM - 'B'

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


4 SCALE: 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0"

6"

PHONE: 303-770-8300
2'-0"
8"
5/4 X 4 TRIM

COLUMN PER 5/4 X 6


8" 2X6
STRUCTURAL HEAD TRIM
ANGLED TRIM

PLAN
5/4 X 4 TRIM THERMA TRU
3-PANEL DOOR
(OR SIMILAR)
8 X 8 FRAMED
BOX COLUMN

5/4 X 4
JAMB TRIM

5/4 X 4 TRIM

SIDE FRONT
ELEVATION ELEVATION

FRONT PORCH COLUMN &


RAILING - 'B' FRONT DOOR - 'B'
5 SCALE: 1/2" = 1'-0" 2 SCALE: 1/2" = 1'-0"

OPT. GLAZING
6X6
CORBEL
10"
4"
6"

6"

2"

WAYNE DALTON
(SERIES 9100)
6"
6" 4"
COLONIAL RAISED
PANEL OVERHEAD
DOOR W/ OPT. GLAZING
(OR SIMILAR)

FRONT SIDE
PROFILE PROFILE

DOOR TRIM (NOT SHOWN) MAY VARY-


RE: FRONT ELEVATION

CORBEL DETAIL - 'B' GARAGE DOOR - 'B'


6 SCALE: N.T.S.
3 SCALE: 1/2" = 1'-0"
©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


TEXTURED PANEL BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
BOARD W/ 5/4 x 4 ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
BATTEN AT 24" O.C. PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


4 IN 12
ASPHALT SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
SHINGLE ROOF (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
12 BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
7 VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
5/4 x 8 TRIM
5/4 x 8 FASCIA W/ MASONRY VENEER AND OTHER WALL CLADDINGS PER
METAL GUTTERS R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.
8" LAP SIDING

1'-3"
12
7 12
HEEL AT 7 IN 12
7

UPPER PLATE / B.O. TRIM

TEXTURED PANEL
WINDOW HEAD
BOARD W/ 5/4 x 4
BATTEN AT 24" O.C.

5/4 x 4
CORNER TRIM
WINDOW TRIM

8'-1 1/8"
RE: DETAIL

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


CORBEL

7'-0"
RE: DETAIL
T.O. TRIM

4 IN 12
5/4 x 8 FASCIA

3'-0"
1'-0 5/8"

12 W/ 5/4 x 4

1'-3"
12 7 SHINGLE STOP
4 HEEL HEIGHT
UPPER LEVEL

PHONE: 303-770-8300
MAIN PLATE / GARAGE HEEL MAIN PLATE / B.O. TRIM

GARAGE PLATE / B.O. TRIM WINDOW HEAD


1'-0"

5/4 x 4 FRIEZE
9'-1 1/8"

9'-1 1/8"
8'-1 1/8"

8'-0"
T.O. CAP
4" LAP SIDING

T.O. CAP

3'-0"
1'-2 1/8"

1'-10"
MAIN LEVEL MAIN LEVEL

T.O. FOUNDATION

PROPOSED RAISED PANEL COLUMN CONC. PORCH


FINISHED GRADE OVERHEAD DOOR RE: DETAIL
RE: DETAIL STEPS PER GRADE
WRAPPED BEAM

FRONT ELEVATION - 'C'


1 SCALE: 1/4" = 1'-0"

5/4 x 4 FRIEZE

7 IN 12

12
4

7 IN 12

4'-0"
RETURN

7 IN 12

1'-0"
RETURN

6'-0" RETURN
5/4 x 4 TRIM

NON-GARAGE SIDE
REMOVE 2040 SH
WINDOW @ OPT.
BEDROOM 3 / BATH 3

ELEVATION - 'C'
2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

ASPHALT UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


SHINGLE ROOF 4 IN 12 SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
5/4 x 8 FASCIA W/
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
METAL GUTTERS
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.
12 12
7 7

5/4 x 4 UPPER PLATE


CORNER TRIM
WINDOW HEAD

8" LAP SIDING

8'-1 1/8"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


7'-0"
WINDOW TRIM

1'-0 5/8"
RE: DETAIL

UPPER LEVEL

PHONE: 303-770-8300
MAIN PLATE

WINDOW HEAD

9'-1 1/8"
8'-0"

1'-2 1/8"
MAIN LEVEL

T.O. FOUNDATION

CONC. STOOP W/
STEPS PER GRADE
PROPOSED
FINISHED GRADE

REAR ELEVATION - 'C'


1 SCALE: 1/4" = 1'-0"

5/4 x 4 FRIEZE
7 IN 12

12
4

7 IN 12

4'-0"
RETURN

7 IN 12

4 IN 12

1'-0"
RETURN 5/4 x 10 TRIM

5/4 x 4 TRIM 6'-0" RETURN

GARAGE SIDE ELEVATION - 'C'


2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

4 IN 12 WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.
12 12
7 7
EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE
BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

5/4 x 8 FASCIA
W/ 5/4 x 4 UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS
SHINGLE STOP SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
5/4 x 4 FRIEZE (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
8" LAP BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
SIDING VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

3 IN 12
12
4

6"
HEEL AT 4 IN 12
EXT. COVERED
PATIO PLATE 5/4 x 8 TRIM

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


9'-1 1/8"

PHONE: 303-770-8300
MAIN LEVEL

COLUMN CONC. PATIO


PROPOSED RE: DETAIL
FINISHED GRADE
OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

REAR ELEVATION - 'C'


1 SCALE: 1/4" = 1'-0"

7 IN 12

12
4

7 IN 12

4'-0"
RETURN

1'-0" RETURN 5/4 x 4 FRIEZE


7 IN 12

5/4 x 8 FASCIA W/ 12 1'-0" 5/4 x 8 FASCIA


3 RETURN
METAL GUTTERS W/ 5/4 x 4
SHINGLE STOP
4 IN 12 12 4 IN 12
3

5"
HEEL HEIGHT
EXT. COVERED PATIO PLATE
5/4 x 8 TRIM

9'-1 1/8"
CONC. PATIO

MAIN LEVEL

REFER TO STANDARD ELEVATION


FOR MORE INFORMATION
6'-0" RETURN
5/4 x 4 TRIM PROPOSED
FINISHED GRADE

OPT. EXT. COVERED PATIO OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

GARAGE SIDE ELEVATION - 'C' NON-GARAGE SIDE ELEVATION - 'C'


3 SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


TEXTURED PANEL BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
BOARD W/ 5/4 x 4 ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
BATTEN AT 24" O.C. PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


4 IN 12
ASPHALT SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
SHINGLE ROOF (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
12 BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
7 VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
5/4 x 8 TRIM
5/4 x 8 FASCIA W/ MASONRY VENEER AND OTHER WALL CLADDINGS PER
METAL GUTTERS R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.
8" LAP SIDING

1'-3"
12
7 12
HEEL AT 7 IN 12
7

UPPER PLATE / B.O. TRIM HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

TEXTURED PANEL
WINDOW HEAD
BOARD W/ 5/4 x 4 • CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
BATTEN AT 24" O.C. TEXTURED PANEL BOARD
• DECORATIVE WINDOW TRIM
5/4 x 4 • CORBEL DETAIL
CORNER TRIM • DECORATIVE COLUMN
WINDOW TRIM

8'-1 1/8"
RE: DETAIL

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


CORBEL

7'-0"
RE: DETAIL
T.O. TRIM

4 IN 12
5/4 x 8 FASCIA

3'-0"
1'-0 5/8"

12 W/ 5/4 x 4

1'-3"
12 7 SHINGLE STOP
4 HEEL HEIGHT
UPPER LEVEL

PHONE: 303-770-8300
MAIN PLATE / GARAGE HEEL MAIN PLATE / B.O. TRIM

GARAGE PLATE / B.O. TRIM WINDOW HEAD


1'-0"

5/4 x 4 FRIEZE
9'-1 1/8"

9'-1 1/8"
8'-1 1/8"

8'-0"
T.O. CAP
4" LAP SIDING

T.O. CAP

3'-0"
1'-2 1/8"

1'-10"
MAIN LEVEL MAIN LEVEL

T.O. FOUNDATION

PROPOSED RAISED PANEL COLUMN CONC. PORCH


FINISHED GRADE OVERHEAD DOOR RE: DETAIL
RE: DETAIL STEPS PER GRADE
WRAPPED BEAM

FRONT ELEVATION - 'C'


1 SCALE: 1/4" = 1'-0"

CORBEL
RE: DETAIL

5/4 x 4 FRIEZE

7 IN 12

12
4

7 IN 12

TEXTURED PANEL
BOARD W/ 5/4 x 2
BATTEN AT 24" O.C.

7 IN 12

1'-0"
RETURN

6'-0" RETURN
5/4 x 4 TRIM

ENHANCED
REMOVE 2040 SH
WINDOW @ OPT.
BEDROOM 3 / BATH 3

NON-GARAGE SIDE ELEVATION - 'C'


2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
REFER TO PLANS AND DETAILS FOR FIRE RATED
ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.
TEXTURED PANEL
BOARD W/ 5/4 x 2
EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE
BATTEN AT 24" O.C.
BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.

ASPHALT UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS


SHINGLE ROOF 4 IN 12 SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
(INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
5/4 x 8 FASCIA W/
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
METAL GUTTERS
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.
12 12
7 7

UPPER PLATE HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

WINDOW HEAD
• CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
TEXTURED PANEL BOARD
5/4 X 8 TRIM
• DECORATIVE WINDOW TRIM
• CORBEL DETAIL
TEXTURED PANEL
• DECORATIVE COLUMN
BOARD W/ 5/4 x 4

8'-1 1/8"
BATTEN AT 24" O.C.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


7'-0"
T.O. TRIM
5/4 x 4
CORNER TRIM

3'-0"

1'-0 5/8"
8" LAP SIDING
UPPER LEVEL

PHONE: 303-770-8300
WINDOW TRIM
RE: DETAIL MAIN PLATE

WINDOW HEAD

9'-1 1/8"
8'-0"

1'-2 1/8"
MAIN LEVEL

T.O. FOUNDATION

CONC. STOOP W/
STEPS PER GRADE
PROPOSED
FINISHED GRADE
ENHANCED
REAR ELEVATION - 'C'
1 SCALE: 1/4" = 1'-0"
SCALE: 1/4" = 1'-0"

CORBEL
RE: DETAIL

TEXTURED PANEL
BOARD W/ 5/4 x 4
BATTEN AT 24" O.C.

5/4 x 4 FRIEZE
7 IN 12

12
4

7 IN 12

ADDITIONAL
WINDOW ADDED
@ ENHANCED
ELEVATION

7 IN 12

4 IN 12

1'-0"
RETURN 5/4 x 10 TRIM

5/4 x 4 TRIM 6'-0" RETURN

ENHANCED
GARAGE SIDE ELEVATION - 'C'
2 SCALE: 1/4" = 1'-0"

©
ELEVATION NOTES

REFER TO GENERAL NOTES FOR ADDITIONAL


INFORMATION NOT REPRESENTED ON ELEVATIONS.

REFER TO BUILDING SECTIONS FOR PLATE HEIGHTS, HEEL


HEIGHTS AND ADDITIONAL INFORMATION NOT
REPRESENTED ON ELEVATIONS.
Godden|Sudik
TEXTURED PANEL REFER TO PLANS AND DETAILS FOR FIRE RATED
BOARD W/ 5/4 x 2 ASSEMBLY LOCATION, PER LOT SPECIFIC CONDITION. A R C H I T E C T S
BATTEN AT 24" O.C. SEE WHAT COULD BE
PENETRATIONS OF PIPES AND SIMILAR TO BE SEALED AT
ALL OPENINGS IN A BUILDING ENVELOPE WALL, FLOOR OR
CEILING ASSEMBLY, PER P2606. PIPES AND VENTS SHALL
BE PAINTED TO MATCH ADJACENT MATERIALS.

4 IN 12 WATERPROOFING OF OPENINGS AT ROOF AND EXTERIOR


WALL PENETRATIONS SHALL BE MADE WATER TIGHT, PER
P2607.

WHEN WINDOWS ARE ADJACENT TO A DOOR, THE BUILDER


MAY ADJUST ADJACENT WINDOW HEADS AND ALL OTHER
WINDOWS IN SAME ROOM TO ALIGN.
12 12
7 7
EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE
BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
CORBEL ENVELOPE, PER R703.2, AND SHALL INCLUDE FLASHING
RE: DETAIL PER R703.4. RE: FLASHING DETAILS, IF APPLICABLE.
5/4 x 8 FASCIA
W/ 5/4 x 4
SHINGLE STOP UNLESS NOTED OTHERWISE, EXTERIOR WALL CLADDINGS
SHALL BE ELEVATED FROM ADJACENT FINISHED GRADE
5/4 x 4 FRIEZE (INCLUDING LANDSCAPE MATERIAL) A MINIMUM OF 4" FOR
BEARING MASONRY VENEER AND 6" FOR ADHERED MASONRY
VENEER AND OTHER WALL CLADDINGS OR 2" ABOVE
ADJACENT FLATWORK OR ROOF SURFACES FOR ADHERED
MASONRY VENEER AND OTHER WALL CLADDINGS PER
R317.1, R404.1.6, R703.9, R703.12.1 AND PER MFG. SPEC'S.

3 IN 12
12
4 HOUSING FACADES FACING PUBLIC AREAS WITH ENHANCED

6"
HEEL AT 4 IN 12
EXT. COVERED • CHANGE IN THE MATERIAL OF THE WALL BY INCORPORATING
PATIO PLATE 5/4 x 8 TRIM TEXTURED PANEL BOARD
• DECORATIVE WINDOW TRIM
• CORBEL DETAIL
• DECORATIVE COLUMN

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


9'-1 1/8"

PHONE: 303-770-8300
MAIN LEVEL

TEXTURED PANEL
COLUMN CONC. PATIO BOARD W/ 5/4 x 4
PROPOSED RE: DETAIL BATTEN AT 24" O.C.
FINISHED GRADE REFER TO STANDARD ELEVATION

ENHANCED OPT. EXT. COVERED FOR MORE INFORMATION

PATIO REAR ELEVATION - 'C'


1 SCALE: 1/4" = 1'-0"

7 IN 12

12
4

7 IN 12

TEXTURED PANEL
BOARD W/ 5/4 x 2
BATTEN AT 24" O.C.

1'-0" RETURN 5/4 x 4 FRIEZE


7 IN 12

5/4 x 8 FASCIA W/ 12 5/4 x 8 FASCIA


3
METAL GUTTERS W/ 5/4 x 4
SHINGLE STOP
4 IN 12 12 4 IN 12
3

5"
HEEL HEIGHT
EXT. COVERED PATIO PLATE

9'-1 1/8"
CONC. PATIO

MAIN LEVEL

REFER TO STANDARD ELEVATION


FOR MORE INFORMATION
6'-0" RETURN
5/4 x 4 TRIM PROPOSED
FINISHED GRADE

ENHANCED OPT. EXT. COVERED ENHANCED OPT. EXT. COVERED PATIO REFER TO STANDARD ELEVATION
FOR MORE INFORMATION

PATIO GARAGE SIDE ELEVATION - 'C' NON-GARAGE SIDE ELEVATION - 'C'


3 SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"

©
Godden|Sudik
A R C H I T E C T S
SEE WHAT COULD BE

5/4 X 4 TRIM

SIMULATED DIVIDED 2"


4 X10 LITES RE: ELEVATIONS
CORBEL FOR LOCATIONS
5/4 X 4
FRIEZE 5/4 X 4 TRIM 5/4 X 4 TRIM

4" 6"
8" 4" 4"
5/4 X 4 TRIM

SIDE FRONT FRONT & ENHANCED STANDARD SIDE &


PROFILE PROFILE ELEVATIONS REAR ELEVATIONS

GABLE END CORBEL DETAIL - 'C' WINDOW TRIM - 'C'

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


4 SCALE: 1/2" = 1'-0" 1 SCALE: 1/2" = 1'-0"

PHONE: 303-770-8300
1'-0"
2"
5/4 X 6 TRIM

COLUMN PER
STRUCTURAL 1'-0"
4/4 X 4 TRIM 5/4 X 4 TRIM

PLAN THERMA TRU


6-PANEL DOOR
(OR SIMILAR)

TEXTURED
PANEL BOARD

5/4 X 4 TRIM
5/4 X 4 TRIM

FRONT PORCH
COLUMN & RAILING - 'C' FRONT DOOR TRIM - 'C'
5 SCALE: 1/2" = 1'-0" 2 SCALE: 1/2" = 1'-0"

6X8
STANDARD
CORBEL
10" GLAZING
4"
8"

4"

WAYNE DALTON
(SERIES 9100)
6" 6" 4" COLONIAL RAISED
PANEL OVERHEAD
DOOR W/ STD. GLAZING
(OR SIMILAR)

FRONT SIDE
PROFILE PROFILE

DOOR TRIM (NOT SHOWN) MAY VARY-


RE: FRONT ELEVATION

CORBEL DETAIL - 'C' GARAGE DOOR - 'C'


6 SCALE: N.T.S.
3 SCALE: 1/2" = 1'-0"
©
BUILDING SECTION NOTES
RE: "GENERAL NOTES", FLOOR PLANS, ROOF PLANS AND
ELEVATIONS FOR ADDITIONAL INFORMATION.
REFER TO ELEVATIONS FOR ADDITIONAL WALL AND PLATE HT.

CONCRETE WALLS - RE: SOILS REPORT FOR SITE


GEOTECHNICAL EVALUATION PER R401.4 AND PERIMETER
FOUNDATION DRAINAGE PER R405. Godden|Sudik
RE: STRUCTURAL FOR REQUIRED DESIGN SPECIFICATIONS OF
WALL, FOOTING AND FLOOR.
A R C H I T E C T S
WALL THICKNESS - 8" UNLESS DIMENSIONED OR NOTED SEE WHAT COULD BE
OTHERWISE. RE: STRUCTURAL.
FOUNDATION WALLS SHALL BE DAMPROOFED, PER R406.1
EXCEPT WHERE REQUIRED TO BE WATERPROOFED, PER
R406.2. APPLY MATERIAL ON FOUNDATION WALLS, THAT
RETAIN EARTH AND ENCLOSE INTERIOR SPACES AND FLOORS
BELOW GRADE FROM TOP OF FOOTING TO FINISHED GRADE.

INSTALL TREATED 2x SILL PLATE ON AN APPROVED AIR SILL


12 SEE STRUCTURAL DRAWINGS TO
4 GASKET OR SILL SEALER. LEVEL, SQUARE AND FASTEN AS
VERIFY TRUSS DIRECTION. REQUIRED. RE: STRUCTURAL.

REINFORCED, (VERIFY THICKNESS PER STRUCT.) SLOPE 1/4"/FT.

1'-0"
RE: SECTION NOTES MIN. TOWARDS O.H. DOORS. PROVIDE PERIMETER EXPANSION
HEEL HEIGHT JOINTS AND CONTROL JOINTS AS REQUIRED.

UPPER PLATE CONCRETE SLAB PER R506 OR STRUCTURAL FLOOR PER SOILS
REPORT AND STRUCT. VAPOR RETARDER PER R506.2.3. CONTROL
JOINTS AND 1/2" EXPANSION JOINT AT FLOOR PERIMETER AND
PENETRATIONS. UNDER-FLOOR SPACE PER R408 IF STRUCT. FLR.
36" H. KNEE PROVIDE INSULATION
WALL W/ CAP - AT ALL EXTERIOR CONC. W/ TURNED DOWN EDGE (RE: STRUCT.). PROVIDE CONC.
OPT. OPEN RAIL WALLS (TYP.) STEPS TO GRADE (FIELD VERIFY). WHERE EXTERIOR PORCHES,
MASTER DECKS, OR STAIRS ATTACH TO A WALL OR FLOOR ASSEMBLY OF

8'-1 1/8"
WOOD-FRAME CONSTRUCTION, PROVIDE APPROVED
BATH FOYER 7 IN 12 CORROSION-RESISTANT FLASHING OR SELF-ADHERED MEMBRANE
RE: SECTION NOTES 90 CLG. AS FLASHING (IN COMPLIANCE WITH AAMA 711) TO PREVENT
80 CLG. ENTRY OF WATER INTO THE WALL CAVITY OR PENETRATION OF
WATER TO THE BUILDING STRUCT. FRAMING COMPONENTS.
SLOPE MIN. 1/4"/FT. AWAY FROM BUILDING. RE: R506 AND R507.2.4.
12

1'-0 5/8"
4
PER R302.13 APPLY 1/2" GYPSUM WALLBOARD OR EQUIVALENT

1'-0"
TO THE UNDERSIDE OF THE MAIN LEVEL FLOOR FRAMING
UPPER LEVEL HEEL HEIGHT ASSEMBLY. INSTALL TIGHT AGAINST SIDE SURFACES OF
MECHANICAL LINES AND OTHER PENETRATIONS. REFER TO
MAIN PLATE COVERED STOOP PLATE R302.13 "EXCEPTIONS" 1 TO 4 FOR NON-APPLICABLE
LOCATIONS AND ALTERNATE APPLICATIONS.

5'-0 7/8"
T&G FLOOR SHEATHING GLUED AND FASTENED ON TJI FLOOR

16R @ 7 5/8" = 10'-1 3/4"


JOISTS. RE: STRUCTURAL FOR SIZES, ALTERNATE FRAMING
TYPES, SPACING AND SPECIFICATIONS. RE: R501.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


STAIRS BEYOND RE: STRUCTURAL FOR FLOOR SYSTEMS AT STAIR LANDINGS,
HABITABLE ATTIC SPACES, ATTIC FLOOR SUPPORTING
RE: SECTION NOTES T.O. LANDING

9'-1 1/8"

9'-1 1/8"
COV. MECHANICAL, STORAGE OR SIMILAR.

STOOP
KITCHEN CONC.
BEARING AND NON-BEARING WALLS - 2x4 WOOD STUDS
UNLESS DIMENSIONED OR NOTED OTHERWISE. FOUNDATION

5'-0 7/8"
90 CLG. AND BASEMENT FLOOR DESIGN MAY REQUIRE FLOATING
WALLS - RE: STRUCTURAL FOR DESIGN SPECIFICATIONS.
M

1'-0 5/8"
IN 1/2" GYPSUM BOARD AND SEALED AIR BARRIER TO INTERIOR

PHONE: 303-770-8300
RE: SECTION NOTES .6
'- 8 SIDE OF WALLS IN THE BUILDING THERMAL ENVELOPE. NOT
"H
EA SLOPE TO REQUIRED AT INTERIOR SIDE OF EXTERIOR GARAGE WALLS
MAIN LEVEL DR MAIN LEVEL UNLESS PER BUILDER SPECIFICATIONS, OR ONLY GYPSUM
OO DRAIN
M BOARD AS REQUIRED PER R302.6.
LOWER PLATE HALF WALL ASSEMBLY SIMILAR WITH CAP PER BUILDER
SPEC'S. RE: PLANS FOR DIMENSIONS.

5'-0 5/8"
INTERIOR FINISHED MATERIALS PER BUILDER SPECIFICATIONS

14R @ 7 5/8" = 8'-10 1/8"


RE: SECTION NOTES AND AS FOLLOWS:
- INTERIOR WALL FINISHES PER R702.
- CEILING FINISHES PER R702 AND R805
UNFINISHED

7'-9 1/2"
PROVIDE SEALED AIR BARRIER AT WALLS ADJACENT TO
BASEMENT T.O. LANDING THERMAL ENVELOPE.
78 CLG. INSULATION PER ENERGY REPORT IN THE WARM IN WINTER
88 CLG. AT OPT. SIDE OF THE WALL STUD CAVITIES THAT COMPRISE THE

3'-9 1/2"
BUILDING THERMAL ENVELOPE. IN FLOOR SYSTEM ABOVE
FULL LOWER LEVEL GARAGE, DROP SOFFITS FOR MECHANICAL AND PLUMBING
LINES AS NECESSARY.
1'-0" PROVIDE VAPOR RETARDER ON THE INTERIOR SIDE AS
LOWER LEVEL REQUIRED, PER R702.7.

OPT. FULL LOWER LEVEL


2x6 WOOD STUDS UNLESS DIMENSIONED OR NOTED
OTHERWISE WITH WALL SHEATHING. RE: STRUCTURAL FOR
DESIGN SPECIFICATIONS.
FIRE-RESISTANT CONSTRUCTION OF EXTERIOR WALLS PER
PROVIDE 1/2" GYP. R302.1 AND MUNICIPALITY REQUIREMENTS.
SEE STRUCTURAL DRAWINGS TO BOARD @ UNDERSIDE WATER-RESISTIVE BARRIER PER R703.2. PROVIDE AS
VERIFY FOUNDATION TYPE - THIS IS OF STAIRS PER R302.7 SPECIFIED OR OTHER APPROVED MATERIAL, OVER
ONLY A GRAPHIC DEPICTION
SHEATHING OF EXTERIOR WALLS AND GABLE END TRUSSES.
NOT REQUIRED FOR DETACHED ACCESSORY BUILDINGS.

BUILDING SECTION - 'A' EXTERIOR COVERING PER R703 - (1) LAYER OF A


WATER-RESISTIVE BARRIER (WRB) MATERIAL TO THE OUTSIDE

1 ELEVATION 'B' & 'C' SIMILAR SCALE: 1/4" = 1'-0"


OF ALL EXTERIOR WALL AND GABLE END TRUSS SHEATHING
PER R703.2. APPLIED FOR
- WOOD, HARDBOARD AND WOOD STRUCTURAL
PANEL SIDING PER R703.5
- FIBER CEMENT SIDING PER R703.10.
EXTERIOR COVERING PER R703 - (2) LAYERS OF A
WATER-RESISTIVE BARRIER (WRB) MATERIAL TO THE OUTSIDE
OF ALL EXTERIOR WALL AND GABLE END TRUSS SHEATHING
12 12 APPLIED FOR;
4 4
- EXTERIOR PLASTER (STUCCO SYSTEM) PER R703.7.3
- STONE AND MASONRY VENEER PER R703.8
- ADHERED MASONRY VENEER PER R703.12.3.
EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE BUILDING
WITH A WEATHER-RESISTANT EXTERIOR WALL ENVELOPE AND
INCLUDE FLASHING, PER R703.4. RE: FLASHING DETAILS.

PROVIDE INSULATION PROVIDE INSULATION


AT ALL EXTERIOR AT ALL EXTERIOR PROVIDE LOAD-BEARING DIMENSION LUMBER FOR TRUSSES,
WALLS (TYP.) WALLS (TYP.) RAFTERS AND CEILING JOISTS PER R802.
TYPICAL ROOF SYSTEM - ROOF SHEATHING PER R803
7 IN 12
FASTENED TO PRE-ENGINEERED TRUSSES PER
MANUFACTURER AND R802.10. RE: STRUCTURAL FOR
ALTERNATE FRAMING TYPES, SPACING AND SPEC'S. PROVIDE
ADEQUATE CUT-OUTS IN SHEATHING AT OVER-FRAMED ROOF
4 IN 12
12 12 LOCATIONS FOR VENTILATION.
4 4

1'-0"

1'-0"
WEATHER PROTECTION OF ROOF DECKS PER R903. INSTALL
HEEL HEIGHT HEEL HEIGHT FLASHING TO PREVENT MOISTURE ENTERING THE WALL AND
ROOF PLANES PER R903.2.
COVERED COVERED
PORCH PLATE PORCH PLATE
FOR UNDERLAYMENT AND ICE BARRIER RE: R905.1.1, R905.1.2.
FOR ROOF MATERIAL TYPE RE, R905.2 TO R905.17.
RE: ROOF PLAN NOTES FOR ADDITIONAL INFORMATION.
STAIRWAYS CONSTRUCTION PER R311.7:
A. 7-3/4" RISERS MAX. - NOT TO VARY MORE THAN 3/8".
COV. B. 10" TREADS MIN. - NOT TO VARY MORE THAN 3/8".
C. WIDTH - NOT LESS THAN 36" CLEAR WIDTH AT ALL

9'-1 1/8"

9'-1 1/8"
COV. PORCH POINTS ABOVE THE PERMITTED HANDRAIL HEIGHT
AND BELOW THE REQUIRED HEADROOM HEIGHT
PORCH CONC.
D. HEADROOM - NOT LESS THAN 6'-8" CLEAR TO ALL
CONC. OBSTRUCTIONS.
E. HANDRAILS - BETWEEN 34" TO 38" A.F.F. PER
R311.7.8 AND GRIP SIZE R311.7.8.
• W/ A CIRCULAR CROSS
SECTION SHALL HAVE AN OUTSIDE DIAMETER OF
SLOPE TO AT LEAST 1-1/4" TO 2". IF NOT CIRCULAR, IT
SLOPE TO
DRAIN MAIN LEVEL MAIN LEVEL SHALL HAVE A PERIMETER DIMENSION OF AT
DRAIN
LEAST 4" TO 6-1/4" W/ MAX. CROSS SECTION OF
2-1/4".
• W/ A PERIMETER GREATER
THAN 6-1/4" SHALL HAVE A GRASPABLE FINGER
RECESS AREA ON BOTH SIDES OF THE PROFILE.
F. THERE SHALL BE A FLOOR OR LANDING AT THE TOP
AND BOTTOM OF EACH STAIRWAY. EXCEPTION: A
FLOOR OR LANDING IS NOT REQUIRED AT THE TOP
OF AN INTERIOR FLIGHT OF STAIRS, INCLUDING
STAIRS IN AN ENCLOSED GARAGE, PROVIDED A
DOOR DOES NOT SWING OVER THE STAIRS.
G. LANDINGS OR FINISHED FLOORS AT THE REQUIRED
EGRESS DOOR SHALL NOT BE MORE THAN 1-1/2"
LOWER THAN THE TOP OF THE THRESHOLD
PROVIDED THE DOOR DOES NOT SWING OVER THE
LANDING. THE EXTERIOR LANDING MAY BE A
MAXIMUM 7-3/4" BELOW THE TOP OF THE
THRESHOLD PROVIDED THE DOOR DOES NOT
SWING OVER THE LANDING.
H. A FLIGHT OF STAIRS SHALL NOT HAVE A VERTICAL
RISE LARGER THAN 151" (12'-7") BETWEEN FLOOR
LEVELS OR LANDINGS, PER R311.7.3.
I. THE WIDTH OF EACH LANDING SHALL NOT BE LESS
THAN THE WIDTH OF THE STAIRWAY SERVED.
EVERY LANDING SHALL HAVE A MINIMUM DIMENSION
OF 36" MEASURED IN THE DIRECTION OF TRAVEL.
RE: R311.7.6
J. OPEN RISERS ARE PERMITTED UNDER 30"
MEASURED VERTICALLY TO FLOOR OR GRADE.
RISERS MORE THAN 30" MUST NOT ALLOW THE

PARTIAL SECTION - 'C' PARTIAL SECTION - 'B' PASSAGE OF A 4" DIAMETER SPHERE, PER
R311.7.5.1.

3 SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"

©
THERMAL BARRIER NOTES
CLASS I, II OR III VAPOR RETARDERS ARE REQUIRED ON THE
INTERIOR SIDE OF FRAME WALLS IN CLIMATE ZONE 5 PER
R702.7.
THE FOLLOWING SHALL BE DEEMED TO MEET THE CLASS
SPECIFIED :
CLASS I: SHEET POLYETHYLENE, ON PERFORATED ALUMINUM
FOIL PER R702.7.2.
CLASS II: KRAFT-FACED FIBERGLASS BATTS PER R702.7.2. Godden|Sudik
CLASS III: LATEX OR ENAMEL PAINT, RE: R702.7.1 AND R702.7.2.
A R C H I T E C T S
THE BUILDING THERMAL ENVELOPE SHALL BE DURABLY SEE WHAT COULD BE
SEALED TO LIMIT INFILTRATION. THE SEALING METHODS
BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR
DIFFERENTIAL EXPANSION AND CONTRACTION. RE: N1102.4.

WHERE NECESSARY, OR AS DIRECTED BY CONTRACTOR,


PROVIDE EXTRUDED POLYSTYRENE IN LIEU OF BATT
INSULATION, BEHIND, BENEATH, OR ADJACENT TO
PLUMBING, MECHANICAL, AND ELECTRICAL SUPPLIES,
RETURNS, AND OTHER DISTRIBUTION LINES AND FIXTURES
TO ENSURE THE MINIMUM INSULATION VALUES ARE
STRICTLY ADHERED TO IN ALL LOCATIONS. IN ALL
INACCESSIBLE OR ENCLOSED AREAS OR AREAS THAT MAY
BE INACCESSIBLE OR MAY BE ENCLOSED, PLACE
EXTRUDED POLYSTYRENE INSULATION IMMEDIATELY
PRIOR TO PLACING THE PLUMBING, MECHANICAL, AND
ELECTRICAL RUNS.

ATTIC ACCESS PANELS SHALL BE EQUIPPED WITH A DURABLE,


INSULATED COVER THAT IS GASKETED TO PRODUCE A
CONTINUOUS AIR SEAL WHEN CLOSED, PER N1102.2.4.

ALL ELECTRICAL BOXES, LIGHT CANS, AND OTHER


PENETRATIONS AT THE CEILING ADJACENT TO
UNCONDITIONED ATTIC SPACE SHALL BE FULLY GASKETED
AND SEALED, PER N1102.4.5 AND TABLE N1102.4.1.1.

INSULATE ALL CANTILEVERED FLOORS WITH INSULATION,


SUFFICIENT TO FILL THE FRAMING CAVITY AND PROVIDE
CLASS I OR II VAPOR RETARDERS ON THE INTERIOR SIDE
OF FRAME, RE: R702.7 AND TABLE N1102.4.1.1.

REFER TO THE GENERAL NOTES INSULATION TABLE


LOCATED ON THE COVER SHEET FOR EITHER
PRESCRIPTIVE PATH (CODE MINIMUM) OR ANTICIPATED
PERFORMANCE PATH INSULATION VALUES (PER PROJECT
ENERGY REPORT). RE: N1102.1 AND TABLE N1102.1.2.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


PHONE: 303-770-8300
PROVIDE INSULATION PROVIDE INSULATION
AT ALL EXTERIOR AT ALL EXTERIOR PROVIDE INSULATION
WALLS - (TYP.) WALLS - (TYP.) AT ALL EXTERIOR
WALLS - (TYP.)

UPPER LEVEL THERMAL MAIN LEVEL THERMAL LOWER LEVEL THERMAL


ENVELOPE DIAGRAM ENVELOPE DIAGRAM ENVELOPE DIAGRAM
3 ALL ELEVATIONS SIMILAR SCALE: 1/8" = 1'-0" 2 ALL ELEVATIONS SIMILAR SCALE: 1/8" = 1'-0" 1 ALL ELEVATIONS SIMILAR SCALE: 1/8" = 1'-0"

©
FLASHING NOTES

DRAWINGS ON THE FLASHING DETAIL SHEETS ARE SHOWN


TO ILLUSTRATE SUGGESTED FLASHING METHODS FOR
GENERIC MATERIALS. REFER TO MANUFACTURERS
INSTALLATION INSTRUCTIONS FOR SPECIFIC MATERIALS
AND PRODUCTS SPECIFIED AND NOTIFY THE ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.

NOTIFY THE ARCHITECT IMMEDIATELY IF A DETAIL IS


Godden|Sudik
MISSING OR A UNIQUE SITUATION IS NOT DETAILED. A R C H I T E C T S
DETAILS ARE GENERIC, REFER TO THE ARCHITECTURAL SEE WHAT COULD BE
DRAWINGS FOR ELEMENT SIZING AND LOCATION. ADJUST
FLASHING AS NECESSARY.

REFER TO THE STRUCTURAL DRAWINGS FOR EXACT


CONFIGURATION, SIZE AND QUANTITY OF STRUCTURAL
AIR SEAL (CONTINUOUS BEAD ELEMENTS. ADJUST FLASHING AS NECESSARY.
OF SEALANT) BETWEEN SILL DETAILS MAY VARY DEPENDING ON CONSTRUCTION
PAN AND WINDOW FRAME SEQUENCING. NOTIFY THE ARCHITECT IMMEDIATELY IF
CHANGES ARE NEEDED.
DISCONTINUOUS
OSB BLOCKS TO CREATE A
BEAD OF EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE
BACK DAM, PLACE IT RIGHT UP
SEALANT BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
AGAINST THE BOTTOM
BETWEEN ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4.
WINDOW FRAME, THE FLEXIBLE
SILL AND SILL
FLASHING WILL BE ADHERED
PAN TO
DIRECTLY TO THE OSB ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
ALLOW PAN
RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
DRAINAGE
PROTECTION PER R903.2 AND ROOF COVERINGS PER R905.
FASTEN FLEXIBLE FLASHING
BACK DAM NO LOWER THAN
INTERMITTENT THE TOP OF OSB BLOCKING
FLANGE
SEALANT
FLEXIBLE
MEMBRANE
PAN FLASHING
WATER RESISTIVE BARRIER
SILL APPLIED LATER
FLASHING

SEALANT

STEP 1- ROLL FLASHING


ACROSS SILL AND TURN UP

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


JAMB AT ENDS (MIN. OF 6")
EXTEND SILL FLASHING
HORIZONTALLY TO PROJECT STEP 2- FOLD OUTSIDE EDGE
EXTERIOR SHEATHING
SQUARE & LEVEL 9" MIN. BEYOND VERTICAL JAMB DOWN AND TO SIDE OF
FRAMING FLASHING APPLIED LATER CORNER
ROUGH
2X FRAMING ROUGH STEP 3- TEMPORARILY SECURE
JAMB FLASHING WIDTH (9" MIN.) WINDOW
STUDS WINDOW EDGE OF CURVE WITH TAPE
OPENING
OPENING

PHONE: 303-770-8300
ROUGH STEP 4- FOLD UP SILL PAN
WINDOW APPLY TAPE AT ENDS AS REFER TO SECTION THROUGH
ROUGH FRAMED OPENING OPENING REQUIRED, TO HOLD FLASHING WINDOW SILL FOR MORE
SUFFICIENTLY LARGER IN INFORMATION ON

MIN. 6"
TEMPORARILY IN PLACE
WIDTH & HEIGHT THAN THE INSTALLATION OF BACK DAM.
ACTUAL FRAME DIMENSIONS
ROUGH OF THE WINDOWS. TO ASSURE
WINDOW ADEQUATE CLEARANCE
OPENING CONSULT THE WINDOW APPLY SILL FLASHING
SEAL THE WINDOW FRAME TO OPENING.
MANUFACTURER'S LITERATURE HORIZONTALLY BELOW THE 3
SILL. FASTEN FLASHING TO APPLY A 8" NOM. DIA. CONTINUOUS
FOR THE RECOMMENDED BEAD OF SEALANT TO THE BACKSIDE
ROUGH OPENING DIMENSIONS. THE FRAMING SO THE
WEATHER RESISTIVE BARRIER (INTERIOR) OF THE WINDOW FLANGE, IN
APPLIED LATER MAY BE LINE WITH ANY PRE-PUNCHED HOLES OR
SLIPPED UP AND UNDERNEATH SLOTS.
THE FLASHING IN WEATHER
BOARD FASHION. **WHERE A PAN FLASHING IS USED, THE
BEAD OF SEALANT AT THE SILL MUST
HAVE DISCONTINUITY IN ORDER TO
PERMIT DRAINAGE FROM THE SILL PAN
TO THE EXTERIOR OR DRAINAGE PLANE.

SHIM AND ADJUST WINDOW TO ACHIEVE SQUARE,


PLUMB, AND LEVEL CONDITION. USE CORROSION
RESISTANT FASTENERS. FASTEN WITHIN 10" AND
NO CLOSER THAN 3" IN EACH DIRECTION FROM
EVERY CORNER. SECURE WINDOW AROUND FRAME
OPENING WITH EQUIVALENT OF 6d FASTENERS AT
16" O.C. MAXIMUM.

**WHERE PAN FLASHING IS TO BE INSTALLED, TYPE III FLEXIBLE MEMBRANE PAN FLASHING- ONE PIECE
INSTALL AFTER SILL FLASHING (BEFORE WINDOW
INSTALLATION)
USE OF PAN FLASHINGS - THIS PRACTICE RECOMMENDS THAT PAN FLASHINGS BE
USED UNDER ALL WINDOWS AND DOORS, EXCEPT WHERE WALL CONSTRUCTION
DETAILS INCORPORATING FENESTRATION DRAINAGE SYSTEMS ARE PROVIDED BY THE
BUILDING DESIGNER, OR WHERE WALL CONSTRUCTION DETAILS ARE SPECIFICALLY FOR MECHANICALLY JOINED FRAMES, APPLY SEALANT AT CORNERS THE FULL LENGTH
THE FRAMING SHALL BE PLUMB, SQUARE, LEVEL AND STRUCTURALLY ADEQUATE. THE STUDS SHALL PROVIDED BY FENESTRATION MANUFACTURERS' INSTALLATION INSTRUCTIONS. OF THE SEAM WHERE MOUNTING FLANGES MEET AND TO THE OUTSIDE OF THE FRAME
BE FREE OF VOIDS, HOLES, CHIPPING, TWISTING, OR OTHER CONDITIONS THAT WILL NOT ALLOW THE A STRIP OF APPROVED FLASHING MATERIAL SHALL BE AT LEAST 9" WIDE. FLASHING WHERE USED, PAN FLASHINGS SHALL BE INTEGRATED WITH THE WALL'S WEATHER CORNER JOINTS.
SEALANT TO MAINTAIN CONTINUOUS CONTACT. SHALL BE APPLIED IN A WEATHERBOARD FASHION AROUND THE FULL PERIMETER OF RESISTIVE BARRIER IN SHINGLE-LAP FASHION. THE PAN FLASHING SHALL BE
THE OPENING ACCORDING TO THE FOLLOWING PROCEDURES: CONTINUOUSLY SEALED TO THE WEATHER RESISTIVE BARRIER. APPLY A CONTINUOUS BEAD OF SEALANT TO THE BACKSIDE (INTERIOR) OF THE
WINDOW MOUNTING FLANGE IN LINE WITH ANY PRE-PUNCHED HOLES OR SLOTS IN
THE ROUGH OPENING SHALL BE LARGER IN BOTH WIDTH AND HEIGHT THAN THE ACTUAL NET APPLY THE FIRST STRIP HORIZONTALLY IMMEDIATELY BELOW THE SILL, CUT IT THESE PAN FLASHING SYSTEMS ARE THE MOUNTING FLANGE. IMMEDIATELY SET THE WINDOW INTO THE OPENING, AND
DIMENSION OF THE PRODUCT TO BE INSTALLED. THE INSTALLER SHALL OBTAIN ALL AVAILABLE PLAN SUFFICIENTLY LONG TO EXTEND AN EQUAL DISTANCE BEYOND THE 9" JAMB FLASHING, FABRICATED FROM ONE OR MULTIPLE PIECES OF A SELF-ADHERING MEMBRANE AND APPLY SHIMS AS REQUIRED TO ENSURE THE UNIT IS PLUMB, LEVEL AND SQUARE.
DETAILS AND CONSTRUCTION DOCUMENTS, AS WELL AS THE MANUFACTURER'S ROUGH OPENING SO THAT IT PROJECTS EVEN WITH THE VERTICAL JAMB FLASHING TO BE APPLIED ARE APPLIED TO CREATE A WATERTIGHT END DAM AND REAR LEG. FASTEN THE WINDOW PERIMETER SECURELY INTO POSITION. WINDOW SHALL BE
REQUIREMENTS AND INSTRUCTIONS. LATER. INSTALLED IN ACCORDANCE WITH THE INSTALLATION PROCEDURES BELOW.
APPLY THE FLASHING MATERIAL TO ADHERE ALONG THE SILL AND WRAP INTO THE
THE INSTALLER SHALL NOTIFY HIS CLIENT IF ANY CONDITIONS EXIST THAT WOULD PREVENT THE FASTEN THE TOP EDGE OF THE SILL FLASHING TO THE FRAMING. PLACE FASTENERS ROUGH OPENING TO FORM A WATERTIGHT PAN FLASHING. THE FLASHING MATERIAL
PROPER INSTALLATION OF THE FENESTRATION PRODUCT, OR PREVENT APPLICATION OF MATERIALS ALONG THE EDGE OF THE ROUGH OPENING WHERE THEY WILL BE COVERED BY THE SHALL EXTEND UP THE JAMBS AND SHALL EXTEND INTO THE ROUGH OPENING WITH SHIM WINDOW AS NECESSARY TO INSURE A SQUARE, LEVEL AND PLUMB
AND COMPONENTS IN ACCORDANCE WITH THIS PRACTICE. MOUNTING FLANGE OF THE WINDOW LATER. PROVISIONS MADE TO SUPPORT THE FORMATION OF A REAR LEG. THE FLASHING INSTALLATION. THE SILL MUST BE SUPPORTED IN A STRAIGHT AND LEVEL POSITION
SHALL EXTEND ONTO THE FACE OF THE SILL APRON AND JAMB FACE FORMING A TO PREVENT SAGGING, DEFLECTION, AND SILL ROTATION.
CLOSED OUTSIDE CORNER.
ROUGH OPENING GAPS SHALL BE INSULATED FOLLOWING THE FENESTRATION PRODUCT DO NOT FASTEN THE BOTTOM EDGE OR THE LAST 9" OF EACH END, AS THE WEATHER SOME MANUFACTURERS REQUIRE A CONTINUOUS SHIM UNDER THE WINDOW SILL.
INSTALLATION TO REDUCE AIR LEAKAGE AND ENERGY LOSS. THE MATERIAL USED TO FILL THE ROUGH RESISTIVE BARRIER WILL BE APPLIED UNDER THE FLASHING IN A WATER SHEDDING FOLLOW MANUFACTURER'S RECOMMENDATIONS.
OPENING GAP SHALL BE SELECTED TO ENHANCE THE ENERGY SAVING PERFORMANCE OF THE FASHION LATER. IT IS RECOMMENDED THAT THE CORNERS AND BOTTOM EDGE BE WHERE PAN FLASHING IS USED, CARE MUST BE TAKEN TO ENSURE A DRAINAGE PATH
FENESTRATION PRODUCT INSTALLATION. TEMPORARILY TAPED AT 24" ON CENTER TO PREVENT WIND DAMAGE. BETWEEN THE WINDOW AND THE SILL PAN. THEREFORE, THE BEAD OF SEALANT ON CLOSE AND LOCK THE WINDOW. SHIM AND ADJUST THE WINDOW AS NECESSARY TO
THE MOUNTING FLANGE AT THE SILL MUST HAVE AT LEAST 2 GAPS AT LEAST 2" WIDE ACHIEVE A PLUMB, SQUARE AND LEVEL CONDITION, AS WELL AS CENTERING THE
GLASS OR MINERAL FIBER INSULATION, ONE COMPONENT POLYURETHANE FOAM SEALANTS, OR TO PERMIT DRAINAGE FROM THE SILL PAN TO THE EXTERIOR OR THE DRAINAGE WINDOW IN THE FRAME OPENING. SECURE THE FULL PERIMETER WITH THE MINIMUM
OTHER CODE APPROVED MATERIAL SHALL BE USED TO FILL THE ROUGH OPENING GAP AS REQUIRED PLANE. THE GAPS IN THE BEAD OF SEALANT MUST BE NO MORE THAN 4FT APART, EQUIVALENT OF 6d FASTENERS ON A MAXIMUM OF 16" O.C. USING PRE-PUNCHED
BY APPLICABLE CODES OR THE CONTRACT DOCUMENTS OR THE FENESTRATION PRODUCT SUCH THAT ADDITIONAL GAPS ARE REQUIRED FOR WINDOWS/DOORS WIDER THAN 4FT HOLES, IF PROVIDED. HINGED AND PIVOTED WINDOWS MAY REQUIRE ADDITIONAL
MANUFACTURER. WIDE. FASTENERS LOCATED NEAR THE HINGE OR PIVOT POINT. FOR CERTAIN WINDOWS IT
MAY BE APPROPRIATE TO FASTEN THE HEAD IN A MANNER TO ALLOW FOR POSSIBLE
MOVEMENT. IN ALL CASES FOLLOW THE MANUFACTURER'S INSTRUCTIONS FOR ANY
EXCESSIVE INSULATING MATERIAL OF ANY MAY DISTORT THE FENESTRATION FRAME, REQUIRING THE AIR INFILTRATION SEALS INSTALLED AROUND WINDOW PERIMETERS MAY, IF SPECIAL PROCEDURES OR APPLICATIONS.
REMOVAL AND RE-INJECTION OF THE PROPER AMOUNT OF INSULATION. TOO LITTLE MATERIAL WILL INCORRECTLY APPLIED, OBSTRUCT DRAINAGE FROM PAN FLASHINGS. TO REDUCE
LEAVE VOIDS IN THE ROUGH OPENING GAP AND PERMIT EXCESS AIR INFILTRATION. THE CHANCE OF THIS OCCURRING, AIR INFILTRATION SEALS SHALL BE APPLIED IN NOTE:
SUCH A MANNER THAT MOISTURE IS NOT TRAPPED INSIDE THE ESTABLISHED AVOID OVERDRIVING FASTENERS. USE AN APPROPRIATELY SIZED FASTENER TO
WEATHER BARRIER PLANE. HOW THIS IS DONE WILL BE GREATLY AFFECTED BY THE COVER THE WIDTH OF ANY PRE-PUNCHED HOLE AND ADEQUATELY SECURE THE
SPECIFIC WALL MATERIAL AND CONFIGURATION. IT IS IMPERATIVE THAT THIS SEALING WINDOW TO THE STRUCTURE.
SYSTEM IS ALSO APPLIED IN SUCH A MANNER THAT THE WINDOW SURFACES INSIDE
OF THE WEATHER BARRIER ARE PROTECTED FROM AIR LEAKAGE AND MOISTURE. AIR IN EACH DIRECTION FROM ALL CORNERS THERE SHALL BE A FASTENER WITHIN 10"
INFILTRATION SEALS CAN REDUCE THE REQUIRED PAN HEIGHTS. BUT NO CLOSER THAN 3" TO PREVENT FRAME DISTORTION OR FRACTURE OF JOINT
SEALS.

THE PAN FLASHING SHOULD BE SECURED IN PLACE TO PREVENT MOVEMENT. AVOID NOTE:
PENETRATION OF THE HORIZONTAL LEG OF THE PAN FLASHING. IF THROUGH-PAN IF ANY DAMAGE TO THE WINDOW FRAME JOINT SEALS OR MOUNTING FLANGES IS
ATTACHMENT CANNOT BE AVOIDED, ATTACH THE PAN THROUGH THE END-DAM JAMB OBSERVED DURING INSTALLATION, THE INSTALLER SHALL REPAIR IT OR CONSULT THE
TABS ABOVE THE UPTURNED REAR LEG. DRIVING FASTENERS THROUGH THE PAN MFG.
WILL COMPROMISE THE WATER TIGHTNESS OF THE PAN. FOR THIS REASON,
ATTACHMENT BY DRIVING FASTENERS THROUGH THE PAN SHALL BE DONE THE OWNER/GENERAL CONTRACTOR IS RESPONSIBLE TO ENSURE THAT THE

WINDOW FLASHING INSTALLATION CAREFULLY AND WITH SEALANT AT THE FASTENERS. USE OF PAN-HEAD SCREWS IS
RECOMMENDED. TO INSTALL SCREWS, DRILL HOLES IN THE PAN AT THE APPROPRIATE
LOCATIONS, FILL THE HOLES WITH SEALANT, AND DRIVE THE SCREWS. ONCE SCREWS
ARE DRIVEN, SEAL OVER THE SCREW HEADS WITH SEALANT TO CREATE A
WEATHER RESISTIVE BARRIER IS EFFECTIVELY INTEGRATED AROUND THE WINDOW
FRAME IN A WEATHERBOARD FASHION.

AFTER INSTALLATION IS COMPLETE, CHECK THE WINDOW FOR PROPER OPERATION


WATERTIGHT INSTALLATION. ONCE THE PAN FLASHING IS SECURED, FILLETS OF

METHOD A
AND LOCKING.
Notice: These Details have been prepared for the use of Contractors SEALANT ARE APPLIED BETWEEN THE UPPER EDGE OF THE OUTER LEG OF THE PAN
and other construction professionals. It has been compiled from FLASHING AND THE BARRIER (SLIGHTLY ABOVE THE BOTTOM CORNERS OF THE
information supplied by testing, research, manufacturing, standards,
and consulting organizations that Godden|Sudik Architects Inc. OPENING), AND THE FILLET BEADS ARE SMOOTHED. THE WINDOW UNIT MAY THEN BE
believes to be competent sources for such data. However, INSTALLED IN THE OPENING.
recognizing that each system must be designed to meet the
particular circumstances; when details vary from manufacturer's
specifications follow the manufacturer's recommendations with
Architects approval. GSA assumes no responsibility or liability of
any kind in connection with these Details or its use by any person or
organization, and makes no representations or warranties of any
kind hereby.

©
FLASHING NOTES

DRAWINGS ON THE FLASHING DETAIL SHEETS ARE SHOWN


TO ILLUSTRATE SUGGESTED FLASHING METHODS FOR
GENERIC MATERIALS. REFER TO MANUFACTURERS
INSTALLATION INSTRUCTIONS FOR SPECIFIC MATERIALS
AND PRODUCTS SPECIFIED AND NOTIFY THE ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.

NOTIFY THE ARCHITECT IMMEDIATELY IF A DETAIL IS


Godden|Sudik
MISSING OR A UNIQUE SITUATION IS NOT DETAILED. A R C H I T E C T S
SEALANT BEAD BEHIND MOUNTING DETAILS ARE GENERIC, REFER TO THE ARCHITECTURAL SEE WHAT COULD BE
FLANGE DRAWINGS FOR ELEMENT SIZING AND LOCATION. ADJUST
FLASHING AS NECESSARY.

REFER TO THE STRUCTURAL DRAWINGS FOR EXACT


CONFIGURATION, SIZE AND QUANTITY OF STRUCTURAL
ELEMENTS. ADJUST FLASHING AS NECESSARY.

DETAILS MAY VARY DEPENDING ON CONSTRUCTION


SEQUENCING. NOTIFY THE ARCHITECT IMMEDIATELY IF
CHANGES ARE NEEDED.

EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
FLEXIBLE MEMBRANE ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4.
PAN FLASHING
ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
PROTECTION PER R903.2 AND ROOF COVERINGS PER R905.

FLASHING

SEALANT BEAD BETWEEN FLASHING AND 6"


MOUNTING FLANGE

OVERLAP ALL VERTICAL


SEAMS AT LEAST 6" AND
OVERLAP ALL
SEAL WITH TAPE
HORIZONTAL SEAMS
FIRST APPLY CONTINUOUS SEAL TO THE RE: MFG. INSTRUCTIONS
AT LEAST 6" SHINGLE
MOUNTING FLANGES AT THE TOP (HEAD)
EMBED BOTTOM OF THE FASHION AND SEAL
AND SIDE (JAMBS) OF WINDOW. EXTEND
1 HEAD FLASHING AGAINST WITH TAPE (THE
SEALANT AT JAMBS 8- 2" ABOVE THE R.O. HIGHER PIECE OF

6" MIN.
AT HEAD. EMBED JAMB FLASHING INTO THE PREVIOUSLY APPLIED
SEALANT (FLASHING GOES BARRIER ON THE
SEALANT AND FASTEN IN PLACE 1
8- 2" OVER SEALANT). EXTEND WALL MUST LAP
HEAD FLASHING BEYOND OVER THE LOWER
FLASHING AT HEAD
EACH JAMB FLASHING, PIECE)
EXTEND 1" BEYOND

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


FASTEN IN PLACE JAMB FLASHING 3RD COURSE OF
WATER-RESISTIVE
1 BARRIER INSTALLED IN
EXTEND JAMB FLASHING TO 2"
LESS THAN THE TOP OF THE TEMPORARILY TAPED A WATER SHEDDING
HEAD FLASHING CORNERS FASHION, TYP.

6" MIN.
A 1
EXTEND JAMB FLASHING TO 2"
LESS THAN THE BOTTOM OF

PHONE: 303-770-8300
THE SILL FLASHING
A

INSTALL 2ND :
APPLY TAPE AT CORNERS TO COURSE OF INSTALL PER WALL FINISH MFG.'S
TEMPORARILY HOLD FLASHING WATER-RESISTIVE RECOMMENDATIONS. SEAL
IN PLACE UNTIL WATER BARRIER (START BETWEEN EXTERIOR FINISHES AND
RESISTIVE BARRIER IS APPLIED FROM BOTTOM TO THE PERIMETER OF THE WINDOW
TOP OF THE WALL). FRAME AT JAMBS AND SILL.
CUT AROUND
OPENING AND
SEAL EDGES WITH
APPROVED TAPE
PER MFG.'S
INSTRUCTIONS.

EXTEND JAMB FLASHING TO OVERLAP


SILL FLASHING. EXTEND JAMB FLASHING
1
8- 2" ABOVE ROUGH OPENING AT HEAD.

1ST COURSE OF WATER


RESISTIVE BARRIER, SLIP UP
AND UNDERNEATH THE SILL
AND JAMB FLASHING

:
USE 1 LAYER OF WATER RESISTIVE
NEXT, APPLY A CONTINUOUS BEAD OF SEALANT TO THE EXPOSED MOUNTING FLANGE CUT THE HEAD FLASHING SUFFICIENTLY LONG SO THAT IT WILL EXTEND BARRIER @ FULL BRICK VENEER. CONTINUE TO APPLY THE WEATHER RESISTIVE BARRIER IN
(EXTERIOR SURFACE) AT THE SIDE JAMBS OF THE INSTALLED WINDOW. CONTINUE APPROXIMATELY 1" BEYOND EACH JAMB FLASHING. INSTALL THE HEAD FLASHING BY USE 2 LAYERS OF WATER RESISTIVE WATER SHEDDING FASHION OVER THE JAMB FLASHING AND OVER
1 PRESSING THE FLASHING INTO THE SEALANT BED PREVIOUSLY APPLIED ACROSS THE BARRIER @ THIN BRICK VENEERS OR THE HEAD OF THE WINDOWS. ATTACH THE WATER RESISTIVE
THE SEALANT BEAD AT THE JAMBS VERTICALLY 8- 2" ABOVE THE ROUGH OPENING AT
THE HEAD OF THE WINDOW (TO THE FACE OF THE HEADER), TO ALLOW FOR THE MOUNTING FLANGE. WHEN APPLYING THE HEAD FLASHING, PRESS THE BOTTOM EDGE STUCCO. BARRIER INTO POSITION USING STAPLES OR OTHER
APPLICATION OF THE TOP PORTION OF THE JAMB FLASHING INTO SEALANT IN THE OF THE FLASHING INTO THE SEALANT UNTIL THE SEALANT APPEARS. THIS WILL APPROPRIATE FASTENERS.
NEXT STEP. THE SEALANT APPLIED HORIZONTALLY ACROSS THE HEAD SHOULD NOT ENSURE THAT NO VOIDS REMAIN BETWEEN THE FLASHING AND THE MOUNTING
EXTEND BEYOND THE JAMB SEALANT. FOR WINDOWS WITH MECHANICALLY JOINED FLANGE. EXTEND THE ENDS OF THE HEAD FLASHING 10" BEYOND THE ROUGH
MOUNTING FLANGES, APPLY SEALANT TO THE FULL LENGTH OF THE JOINTS OR SEAM OPENING, OVER THE TOP OF THE JAMB FLASHING. FASTEN THE HEAD FLASHING INTO WHENEVER APPLYING THE WEATHER RESISTIVE BARRIER,
WHERE THE FLANGES MEET. PLACE ALONG THE TOP EDGE USING STAPLES OR OTHER APPROPRIATE FASTENERS. FLASHING, OR OTHER MATERIALS DO NOT PENETRATE THE
MOUNTING FLANGE WITH THE FASTENERS.
THE BUILDING SHALL BE CONSTRUCTED IN SUCH A MANNER TO SECURE OR SUPPORT
THE APPLICATION OF SEALANT TO THE EXTERIOR FACE OF THE FLANGE IS NOT THE FLASHING TO PREVENT DESTRUCTION OR DISPLACEMENT PRIOR TO
NECESSARY IF USING SELF-ADHESIVE TYPE FLASHING OVER THE MOUNTING FLANGE. INSTALLATION OF THE WEATHER RESISTIVE BARRIER. THE FLASHING SHALL NEVER BE
A CONTINUOUS BEAD OF SEALANT SHALL BE APPLIED TO THE BACK SIDE OF THE LEFT UNSUPPORTED AND VULNERABLE TO WIND DAMAGE.
MOUNTING FLANGE PRIOR TO PLACING THE WINDOW.

WHERE RECOMMENDED AS PART OF THE EXTERIOR WALL FINISH SYSTEM, INSTALL


THE WEATHER RESISTIVE BARRIER AS OUTLINED. THE APPLICATION OF THE WEATHER
RESISTIVE BARRIER MAY BE BY TRADES OTHER THAN THE WINDOW INSTALLER. THE
CONTRACTOR SHALL COORDINATE THIS WORK AS REQUIRED.
APPLY THE SEALANT IN LINE WITH PRE-PUNCHED HOLES OR SLOTS ON THE THE
MOUNTING FLANGE WHEN PROVIDED AND OVER THE HEADS OF THE FASTENERS.

NEXT, STARTING AT EACH JAMB, EMBED THE JAMB FLASHING INTO THE SEAL AND
FASTEN IN PLACE. ATTACH THE FLASHING INTO POSITION TO THE ROUGH OPENING
FRAMING USING STAPLES OR OTHER APPROPRIATE FASTENERS. DO NOT FASTEN THE
BOTTOM 9" OF THE JAMB FLASHING, SO THE WEATHER RESISTIVE BARRIER APPLIED
LATER MAY BE SLIPPED UP AND UNDERNEATH THE FLASHING IN A WEATHERBOARD
FASHION. EXTEND THIS FLASHING TO APPROXIMATELY 12" LESS THAN THE BOTTOM
1
SILL FLASHING AND BEYOND THE TOP OF THE WINDOW TO APPROXIMATELY 2" LESS
THEN THE TOP OF THE HEAD FLASHING.

WINDOW FLASHING INSTALLATION


METHOD A

©
FLASHING NOTES

DRAWINGS ON THE FLASHING DETAIL SHEETS ARE SHOWN


TO ILLUSTRATE SUGGESTED FLASHING METHODS FOR
GENERIC MATERIALS. REFER TO MANUFACTURERS
INSTALLATION INSTRUCTIONS FOR SPECIFIC MATERIALS
AND PRODUCTS SPECIFIED AND NOTIFY THE ARCHITECT
AIR SEAL (CONTINUOUS BEAD
OF SEALANT) BETWEEN SILL
IMMEDIATELY OF ANY DISCREPANCIES.

NOTIFY THE ARCHITECT IMMEDIATELY IF A DETAIL IS


Godden|Sudik
PAN AND WINDOW FRAME
MISSING OR A UNIQUE SITUATION IS NOT DETAILED. A R C H I T E C T S
DETAILS ARE GENERIC, REFER TO THE ARCHITECTURAL SEE WHAT COULD BE
OSB BLOCKS TO CREATE A DRAWINGS FOR ELEMENT SIZING AND LOCATION. ADJUST
BACK DAM, PLACE IT RIGHT UP FLASHING AS NECESSARY.
AGAINST THE BOTTOM
WINDOW FRAME, THE FLEXIBLE REFER TO THE STRUCTURAL DRAWINGS FOR EXACT
FLASHING WILL BE ADHERED CONFIGURATION, SIZE AND QUANTITY OF STRUCTURAL
DIRECTLY TO THE OSB ELEMENTS. ADJUST FLASHING AS NECESSARY.

DETAILS MAY VARY DEPENDING ON CONSTRUCTION


SEQUENCING. NOTIFY THE ARCHITECT IMMEDIATELY IF
CHANGES ARE NEEDED.
FASTEN FLEXIBLE FLASHING
INTERMITTENT BACK DAM NO LOWER THAN
FLANGE THE TOP OF OSB BLOCKING EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE
CUT TOP PORTION TO CREATE SEALANT BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
FLAP, THEN RAISE AND TAPE ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4.
FLEXIBLE
TEMPORARILY TO HEAD MEMBRANE PAN
CONDITION TO ALLOW HEAD FLASHING ROOF ASSEMBLIES SHALL PROVIDE A WEATHER
FLASHING INSTALLATION WATER RESISTIVE BARRIER RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
SILL
FLASHING PROTECTION PER R903.2 AND ROOF COVERINGS PER R905.
(PER ASTM E 2112-07)
WATER RESISTIVE BARRIER 9" MIN. VERTICAL LAP TYP.
SHEATHING IS TEMPORARILY
EXPOSED
45°
CUT WRB FLUSH WITH
9"
R.O. AT HEAD
9"
EXTEND SILL FLASHING
HORIZONTALLY TO PROJECT
9" MIN. BEYOND VERTICAL JAMB
FLASHING APPLIED LATER
STEP 1- ROLL FLASHING
JAMB FLASHING WIDTH (9" MIN.) ACROSS SILL AND TURN UP
JAMB AT ENDS (MIN. OF 6")
CUT LINE
MAKE A MODIFIED "I" CUT IN STEP 2- FOLD OUTSIDE EDGE
THE WEATHER RESISTIVE DOWN AND TO SIDE OF
BARRIER (SEE CUT LINE) THEN CORNER
WRAP WRB TO INTERIOR AT

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SILL AND JAMBS AND STAPLE IN STEP 3- SECURE EDGE OF
PLACE. CURVES WITH TAPE TO
ENSURE ADHERENCE TO THE
APPLY SILL FLASHING WATER RESISTIVE BARRIER
HORIZONTALLY LEVEL WITH
THE TOP EDGE OF THE ROUGH STEP 4- FOLD UP SILL PAN, 4"
OPENING. MIN. REFER TO SECTION

MIN. 6"
OVERLAP VERTICAL AND
SEE NOTE BELOW THROUGH WINDOW SILL FOR
HORIZONTAL SEAMS PER CODE
DIMENSIONS. SEAMS MAY BE MORE INFORMATION ON

PHONE: 303-770-8300
SEALED WITH MFG. APPROVED INSTALLATION OF BACK DAM.
TAPE.
INSTALL TAPE AS EACH LAYER

6" MIN. HORIZONTAL


OF WATER RESISTIVE BARRIER

INSTRUCTIONS
IS INSTALLED.

LAP PER MFG.


WATER RESISTIVE BARRIER

WATER RESISTIVE BARRIER

**WHERE PAN FLASHING IS TO BE INSTALLED, TYPE III FLEXIBLE MEMBRANE PAN FLASHING- ONE PIECE
INSTALL AFTER SILL FLASHING (BEFORE WINDOW
INSTALLATION) USE OF PAN FLASHINGS - THIS PRACTICE RECOMMENDS THAT PAN FLASHINGS BE USED UNDER ALL WINDOWS AND DOORS, EXCEPT WHERE
WALL CONSTRUCTION DETAILS INCORPORATING FENESTRATION DRAINAGE SYSTEMS ARE PROVIDED BY THE BUILDING DESIGNER, OR WHERE
APPLY THE HORIZONTAL SILL FLASHING MATERIAL NEXT, LEVEL WITH THE TOP EDGE OF THE ROUGH WALL CONSTRUCTION DETAILS ARE SPECIFICALLY PROVIDED BY FENESTRATION MANUFACTURERS' INSTALLATION INSTRUCTIONS. WHERE
OPENING. CUT THE SILL FLASHING LONG ENOUGH TO EXTEND AN EQUAL DISTANCE BEYOND THE 9" USED, PAN FLASHINGS SHALL BE INTEGRATED WITH THE WALL'S WEATHER RESISTIVE BARRIER IN SHINGLE-LAP FASHION. THE PAN FLASHING
WEATHER RESISTIVE BARRIER APPLIED PRIOR TO THE WINDOW INSTALLATION-FLASHING APPLIED SHALL BE CONTINUOUSLY SEALED TO THE WEATHER RESISTIVE BARRIER.
JAMB FLASHING, WHICH WILL BE APPLIED LATER. FASTEN THE TOP EDGE OF THE SILL FLASHING TO
OVER THE FACE OF THE MOUNTING FLANGE.
THE FRAMING. PLACE FASTENERS ALONG THE EDGE OF THE ROUGH OPENING WHERE THEY WILL BE
COVERED BY THE MOUNTING FLANGE OF THE WINDOW LATER. THESE PAN FLASHING SYSTEMS ARE FABRICATED FROM ONE OR MULTIPLE PIECES OF A
WHERE A WEATHER RESISTIVE BARRIER IS USED, APPLY THE WATER RESISTIVE BARRIER IN WATER SELF-ADHERING MEMBRANE AND ARE APPLIED TO CREATE A WATERTIGHT END DAM AND REAR LEG.
SHEDDING FASHION, STARTING AT THE BASE OF THE WALL AND WORKING TOWARDS THE TOP.
INSTALL THE WEATHER RESISTIVE BARRIER TO THE FACE OF THE BUILDING FRAMING OR SHEATHING APPLY THE FLASHING MATERIAL TO ADHERE ALONG THE SILL AND WRAP INTO THE ROUGH OPENING TO FORM A WATERTIGHT PAN FLASHING.
FLUSH WITH THE ROUGH OPENING OF THE WINDOW HEAD, JAMBS AND SILL. THE FLASHING MATERIAL SHALL EXTEND UP THE JAMBS AND SHALL EXTEND INTO THE ROUGH OPENING WITH PROVISIONS MADE TO SUPPORT
WHERE THE WEATHER RESISTIVE BARRIER USED IS A BUILDING PAPER TYPE MATERIAL AND COVERS THE FORMATION OF A REAR LEG. THE FLASHING SHALL EXTEND ONTO THE FACE OF THE SILL APRON AND JAMB FACE FORMING A CLOSED
THE WINDOW, CAREFULLY CUT THE BARRIER IN A MODIFIED "I" PATTERN. FOLD THE BOTTOM AND SIDE OUTSIDE CORNER.
FLAPS OVER AND BEHIND THE INTERIOR SIDE OF THE FRAMING. ATTACH THE BARRIER INTO POSITION
ON THE INSIDE OF THE ROUGH OPENING. AT THE HEAD OF THE OPENING, STARTING AT THE TOP
CORNER OF THE WINDOW, MEASURE FROM THE CORNER 9" UP AND 9" OVER AND MARK. AT A 45° WHERE PAN FLASHING IS USED, CARE MUST BE TAKEN TO ENSURE A DRAINAGE PATH BETWEEN THE WINDOW AND THE SILL PAN. THEREFORE,
ANGLE, CAREFULLY CUT THE BARRIER ON A DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE THE BEAD OF SEALANT ON THE MOUNTING FLANGE AT THE SILL MUST HAVE AT LEAST 2 GAPS AT LEAST 2" WIDE TO PERMIT DRAINAGE FROM
BARRIER UP AND TEMPORARILY TAPE THE TOP CORNERS AND CENTER TO THE EXTERIOR WEATHER THE SILL PAN TO THE EXTERIOR OR THE DRAINAGE PLANE. THE GAPS IN THE BEAD OF SEALANT MUST BE NO MORE THAN 4FT APART, SUCH
RESISTIVE BARRIER SURFACE ABOVE. THIS IS DONE IN ORDER TO ALLOW FOR INSTALLATION OF THE THAT ADDITIONAL GAPS ARE REQUIRED FOR WINDOWS/DOORS WIDER THAN 4FT WIDE.
WINDOW AND FLASHING LATER.

AIR INFILTRATION SEALS INSTALLED AROUND WINDOW PERIMETERS MAY, IF INCORRECTLY APPLIED, OBSTRUCT DRAINAGE FROM PAN
AT THE HEAD OF THE OPENING, STARTING AT THE TOP CORNER OF THE WINDOW, MEASURE FROM THE FLASHINGS. TO REDUCE THE CHANCE OF THIS OCCURING, AIR INFILTRATION SEALS SHALL BE APPLIED IN SUCH A MANNER THAT MOISTURE IS
CORNER 9" UP AND 9" OVER AND MARK. AT A 45° ANGLE, CAREFULLY CUT THE BARRIER ON A NOT TRAPPED INSIDE THE ESTABLISHED WEATHER BARRIER PLANE. HOW THIS IS DONE WILL BE GREATLY AFFECTED BY THE SPECIFIC WALL
DIAGONAL. GENTLY RAISE THE TOP EDGE OF THE BARRIER UP AND TEMPORARILY TAPE THE TOP MATERIAL AND CONFIGURATION. IT IS IMPERATIVE THAT THIS SEALING SYSTEM IS ALSO APPLIED IN SUCH A MANNER THAT THE WINDOW
CORNERS AND CENTER TO THE EXTERIOR WEATHER RESISTIVE BARRIER SURFACE ABOVE. THIS IS SURFACES INSIDE OF THE WEATHER BARRIER ARE PROTECTED FROM AIR LEAKAGE AND MOISTURE. AIR INFILTRATION SEALS CAN REDUCE THE
DONE IN ORDER TO ALLOW FOR INSTALLATION OF THE WINDOW AND FLASHING LATER. REQUIRED PAN HEIGHTS.

NOTE:
WEATHER RESISTIVE BARRIER SHALL BE CONTINUOUS, WITHOUT JOINTS UNDER WINDOW AND WITHIN
24" OF WINDOW IN ALL DIRECTIONS

WINDOW FLASHING INSTALLATION


METHOD A1
W/ PAN FLASHING
Notice: These Details have been prepared for the use of Contractors
and other construction professionals. It has been compiled from
information supplied by testing, research, manufacturing, standards,
and consulting organizations that Godden|Sudik Architects Inc.
believes to be competent sources for such data. However,
recognizing that each system must be designed to meet the
particular circumstances; when details vary from manufacturer's
specifications follow the manufacturer's recommendations with
Architects approval. GSA assumes no responsibility or liability of
any kind in connection with these Details or its use by any person or
organization, and makes no representations or warranties of any
kind hereby.

©
FLASHING NOTES

DRAWINGS ON THE FLASHING DETAIL SHEETS ARE SHOWN


TO ILLUSTRATE SUGGESTED FLASHING METHODS FOR
SEALANT BEAD BEHIND MOUNTING GENERIC MATERIALS. REFER TO MANUFACTURERS
FLANGE INSTALLATION INSTRUCTIONS FOR SPECIFIC MATERIALS
AND PRODUCTS SPECIFIED AND NOTIFY THE ARCHITECT
IMMEDIATELY OF ANY DISCREPANCIES.

NOTIFY THE ARCHITECT IMMEDIATELY IF A DETAIL IS


Godden|Sudik
MISSING OR A UNIQUE SITUATION IS NOT DETAILED. A R C H I T E C T S
DETAILS ARE GENERIC, REFER TO THE ARCHITECTURAL SEE WHAT COULD BE
DRAWINGS FOR ELEMENT SIZING AND LOCATION. ADJUST
FLASHING AS NECESSARY.

REFER TO THE STRUCTURAL DRAWINGS FOR EXACT


CONFIGURATION, SIZE AND QUANTITY OF STRUCTURAL
ELEMENTS. ADJUST FLASHING AS NECESSARY.
FLEXIBLE MEMBRANE PAN FLASHING DETAILS MAY VARY DEPENDING ON CONSTRUCTION
SEQUENCING. NOTIFY THE ARCHITECT IMMEDIATELY IF
CHANGES ARE NEEDED.

WATER RESISTIVE BARRIER EXTERIOR WALL ASSEMBLIES SHALL PROVIDE THE


WATER RESISTIVE BARRIER BUILDING WITH A WEATHER RESISTANT EXTERIOR WALL
ENVELOPE AND SHALL INCLUDE FLASHING PER R703.4.

FLASHING ROOF ASSEMBLIES SHALL PROVIDE A WEATHER


SEALANT
RESISTANT ROOF SYSTEM AND SHALL INCLUDE WEATHER
PROTECTION PER R903.2 AND ROOF COVERINGS PER R905.
SEALANT BEAD BETWEEN FLASHING AND
MOUNTING FLANGE

EXTEND SEALANT AT
1 EMBED BOTTOM OF THE HEAD
JAMBS 8- 2" ABOVE THE
R.O. AT HEAD. EMBED FLASHING AGAINST THE
JAMB FLASHING INTO PREVIOUSLY APPLIED SEALANT INSTALL ADDITIONAL LAYER
SEALANT AND FASTEN IN (FLASHING GOES OVER OF WEATHER RESISTIVE
PLACE SEALANT). EXTEND HEAD BARRIER (INTEGRATE WITH
1 FLASHING BEYOND EACH JAMB
8- 2" FLASHING AT HEAD W.R.B. ABOVE W/ MIN. 6"
FLASHING, FASTEN IN PLACE EXTEND 1" BEYOND LAPPING) TO COMPLETELY
JAMB FLASHING COVER THE HEAD FLASHING
AND ANGLE CUT.

1
EXTEND JAMB FLASHING TO 2"

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


LESS THAN THE TOP OF THE
HEAD FLASHING
SEAL THE WINDOW FRAME TO OPENING.
3
APPLY A 8" NOM. DIA. CONTINUOUS A 1
EXTEND JAMB FLASHING TO 2"
BEAD OF SEALANT TO THE BACKSIDE LESS THAN THE BOTTOM OF
(INTERIOR) OF THE WINDOW FLANGE, IN THE SILL FLASHING
LINE WITH ANY PRE-PUNCHED HOLES OR A EXTERIOR WALL FINISH:
SLOTS. INSTALL PER MFG.

PHONE: 303-770-8300
RECOMMENDATION. SOME
DISCONTINUOUS BEAD OF SEALANT
EXTERIOR FINISHES MAY
BEHIND THE WINDOW SILL NAIL FIN ONLY
REQUIRE SEALING BETWEEN
IN ORDER TO ACCOMODATE DRAINAGE
THE PERIMETER OF THE
BETWEEN THE NAIL FIN AND THE
WINDOW FRAME.
FLEXIBLE MEMBRANE FLASHING.

SHIM AND ADJUST WINDOW TO ACHIEVE


SQUARE, PLUMB, AND LEVEL CONDITION.
USE CORROSION RESISTANT
FASTENERS. FASTEN WITHIN 10" AND NO
CLOSER THAN 3" IN EACH DIRECTION EXTEND JAMB FLASHING TO
FROM EVERY CORNER. SECURE OVERLAP SILL FLASHING.
1
WINDOW AROUND FRAME OPENING WITH EXTEND JAMB FLASHING 8- 2"
EQUIVALENT OF 6d FASTENERS AT 16" ABOVE ROUGH OPENING AT
O.C. MAXIMUM. HEAD.

APPLY A CONTINUOUS BEAD OF SEALANT TO THE BACK SIDE (INTERIOR SURFACE) OF APPLY A CONTINUOUS BEAD OF SEALANT TO THE EXPOSED MOUNTING FLANGE APPLY A CONTINUOUS BEAD OF SEALANT TO THE EXPOSED MOUNTING FLANGE
THE MOUNTING FLANGE OF THE WINDOW. PROVIDE A DISCONTINUOUS SEALANT BEAD (EXTERIOR SURFACE) AT THE SIDE JAMBS OF THE INSTALLED WINDOW. (EXTERIOR SURFACE) AT THE HEAD OF THE INSTALLED WINDOW.
REMOVE THE PREVIOUSLY APPLIED TAPE, WHICH HOLDS THE FLAP OF THE WEATHER
BEHIND THE WINDOW SILL NAIL FIN ONLY IN ORDER TO ACCOMMODATE DRAINAGE
RESISTIVE BARRIER AT THE HEAD. ALLOW THE FLAP TO LAY FLAT OVER THE HEAD
BETWEEN THE NAIL FIN AND THE FLEXIBLE MEMBRANE FLASHING. IMMEDIATELY SET NOTE: NOTE:
FLASHING. APPLY A NEW PIECE OF WEATHER RESISTIVE BARRIER OVER THE ENTIRE
THE WINDOW INTO THE OPENING, AND APPLY SHIMS AS REQUIRED TO ENSURE THE THE APPLICATION OF THE ADDITIONAL BEAD OF SEALANT TO THE FLANGE MAY NOT BE THE APPLICATION OF SEALANT TO THE FLANGE IS NOT NECESSARY IF USING
DIAGONAL CUT MADE IN THE WEATHER RESISTIVE BARRIER. THE WEATHER RESISTIVE
UNIT IS PLUMB, LEVEL, AND SQUARE. FASTEN THE WINDOW PERIMETER SECURELY NECESSARY IF USING SELF-ADHESIVE TYPE FLASHING OVER THE MOUNTING FLANGE, SELF-ADHESIVE TYPE FLASHING OVER THE MOUNTING FLANGE.
BARRIER SHOULD BE INTEGRATED WITH PROPER LAPPING OF AT LEAST 6" WITH THE
INTO POSITION. AS LONG AS THE FLASHING SECURELY ADHERES. SOME FLASHING MANUFACTURERS
WEATHER RESISTIVE BARRIER AS IT GOES UP THE WALL.
REFER TO THE DETAILED INSTALLATION INSTRUCTIONS BELOW. MAY REQUIRE THE USE OF PRIMER MATERIALS TO HELP FACILITATE THE BONDING TO APPLY THE SEALANT IN LINE WITH THE PRE-PUNCHED HOLES OR SLOTS ON THE
THE VARIOUS SUBSTRATES. WHEN USING SEALANT NEAR SELF-ADHESIVE FLASHING, MOUNTING FLANGE WHEN PROVIDED AND OVER THE HEADS OF THE FASTENERS.
NOTE: DO NOT USE SEALANT THAT CONTAINS SOLVENT. ALWAYS CONSULT WITH THE
APPLY SEALANT IN LINE WITH THE PRE-PUNCHED HOLES OR SLOTS ON THE MOUNTING FLASHING SUPPLIER TO DETERMINE COMPATABILITY WITH THE VARIOUS NEXT, INSTALL THE HEAD FLASHING BY PRESSING THE FLASHING INTO THE SEALANT
FLANGE WHEN PROVIDED. INSTALLATION MATERIALS AND TO OBTAIN SPECIFIC INSTALLATION TECHINQUES. BEAD PREVIOUSLY APPLIED ACROSS THE MOUNTING FLANGE. WHEN APPLYING THE
HEAD FLASHING, PRESS THE BOTTOM EDGE OF THE FLASHING INTO THE SEALANT
WHERE PAN FLASHING IS USED, THE BEAD OF SEALANT AT THE SILL MUST HAVE 1 UNTIL THE SEALANT APPEARS. THIS WILL ENSURE THAT NO VOIDS REMAIN BETWEEN
1. CONTINUE THE SEALANT BEAD AT THE JAMBS VERTICALLY 8- 2" ABOVE THE ROUGH
DISCONTINUITY IN ORDER TO PERMIT DRAINAGE FROM THE SILL PAN TO THE OPENING AT THE HEAD OF THE WINDOW (TO THE FACE OF THE HEADER), TO ALLOW THE FLASHING AND THE MOUNTING FLANGE. EXTEND THE ENDS OF THE HEAD
EXTERIOR OR DRAINAGE PLANE. FOR APPLICATION OF THE TOP PORTION OF THE JAMB FLASHING INTO SEALANT IN THE FLASHING 10" BEYOND THE ROUGH OPENING, OVER THE TOP OF THE JAMB FLASHING.
NEXT STEP. FASTEN THE HEAD FLASHING INTO PLACE ALONG THE TOP EDGE USING STAPLES OR
OTHER APPROPRIATE FASTENERS.
SHIM WINDOW AS NECESSARY TO INSURE A SQUARE, LEVEL AND PLUMB NOTE:
INSTALLATION. THE SILL MUST BE SUPPORTED IN A STRAIGHT AND LEVEL POSITION APPLY THE SEALANT IN LINE WITH THE PRE-PUNCHED HOLES OR SLOTS ON THE
TO PREVENT SAGGING, DEFLECTION, AND SILL ROTATION. MOUNTING FLANGE WHEN PROVIDED AND OVER THE HEADS OF THE FASTENERS.

SOME MANUFACTURERS REQUIRE A CONTINUOUS SHIM UNDER THE WINDOW SILL. 2. FOR WINDOWS WITH MECHANICALLY JOINED MOUNTING FLANGES, APPLY SEALANT
FOLLOW MANUFACTURER'S RECOMMENDATIONS. TO THE FULL LENGTH OF THE JOINTS OR SEAM WHERE THE FLANGES MEET.

CLOSE AND LOCK THE WINDOW. SHIM AND ADJUST THE WINDOW AS NECESSARY TO NEXT, INSTALL THE JAMB FLASHING BY PRESSING THE FLASHING INTO THE SEALANT
ACHIEVE A PLUMB, SQUARE AND LEVEL CONDITION, AS WELL AS CENTERING THE BEADS ON THE MOUNTING FLANGES. ATTACH THE FLASHING INTO POSITION TO THE
WINDOW IN THE FRAME OPENING. SECURE THE FULL PERIMETER WITH THE MINIMUM ROUGH OPENING FRAMING USING STAPLES OR OTHER APPROPRIATE FASTENERS.
EQUIVALENT OF 6d FASTENERS ON A MAXIMUM OF 16" O.C. USING PRE-PUNCHED 1
EXTEND THE BOTTOM EDGE OF THE JAMB FLASHING 8- 2" BEYOND THE ROUGH
HOLES, IF PROVIDED. HINGED AND PIVOTED WINDOWS MAY REQUIRE ADDITIONAL 1
OPENING SILL, AND EXTEND THE TOP EDGE 8- 2" BEYOND THE ROUGH OPENING HEAD,
FASTENERS LOCATED NEAR THE HINGE OR PIVOT POINT. FOR CERTAIN WINDOWS IT WHERE THE HEAD FLASHING WILL BE PLACED NEXT. TUCK THE TOP OF THE JAMB
MAY BE APPROPRIATE TO FASTEN THE HEAD IN A MANNER TO ALLOW FOR POSSIBLE FLASHING UNDER THE FLAP OF THE WEATHER RESISTIVE BARRIER.
MOVEMENT. IN ALL CASES FOLLOW THE MANUFACTURER'S INSTRUCTIONS FOR ANY
SPECIAL PROCEDURES OR APPLICATIONS.

NOTE:
AVOID OVERDRIVING FASTENERS. USE AN APPROPRIATELY SIZED FASTENER TO
COVER THE WIDTH OF ANY PRE-PUNCHED HOLE AND ADEQUATELY SECURE THE
WINDOW TO THE STRUCTURE.

IN EACH DIRECTION FROM ALL CORNERS THERE SHALL BE A FASTENER WITHIN 10"
BUT NO CLOSER THAN 3" TO PREVENT FRAME DISTORTION OR FRACTURE OF JOINT
SEALS.

NAILS TO BE NO MORE THAN 16" O.C.

NO NAILS SHALL BE BENT OVER NAILING FIN TO SECURE WINDOW

NOTE:
IF ANY DAMAGE TO THE WINDOW FRAME JOINT SEALS OR MOUNTING FLANGES IS
OBSERVED DURING INSTALLATION, THE INSTALLER SHALL REPAIR IT OR CONSULT THE
WINDOW FLASHING INSTALLATION
MFG.

THE OWNER/GENERAL CONTRACTOR IS RESPONSIBLE TO ENSURE THAT THE


WEATHER RESISTIVE BARRIER IS EFFECTIVELY INTEGRATED AROUND THE WINDOW
FRAME IN A WEATHERBOARD FASHION.
METHOD A1
AFTER INSTALLATION IS COMPLETE, CHECK THE WINDOW FOR PROPER OPERATION
AND LOCKING.
W/ PAN FLASHING

©
PROVIDE FURRING STRIPS, MIN. 3 8" DOUBLE LAYER SPLINE OF
EXTERIOR SHEATHING BUILDING PAPER APPLIED GALVANIZED METAL
THICK, 1 12" WIDE, BETWEEN
FLASHING REQ'D ONLY
WATER-RESISTIVE BARRIER &
HARDBOARD PANEL SIDING. WATER-RESISTIVE BARRIER - PER
VERTICALLY (IF USING
ASPHALT FELT, SPLIT 36" WIDE
SHEET IN HALF), NOT NEEDED
WHEN USING 2 LAYERS
OF GRADE D PAPER
Godden|Sudik
BUILDING CODE
INSTALL PER MANUFACTURER'S
RECOMMENDATIONS.
FOR PLASTIC HOUSEWRAPS A R C H I T E C T S
HORIZONTAL LAP SIDING SEE WHAT COULD BE
EXTERIOR SHEATHING
STARTER STRIP
WATER-RESISTIVE BARRIER - PER ASPHALT-
BUILDING CODE 1/4" GAP MIN. SATURATED
BETWEEN FLASHING AND SIDING FELT PAPER
HARDBOARD PANEL SIDING PER
BUILDER
GALVANIZED FLASHING TURN UP
1/4" GAP MIN. WALL MIN. 2" AND LAP W/ WRB
BETWEEN FLASHING AND SIDING

GALVANIZED FLASHING TURN UP


WALL MIN. 2" AND LAP W/ WRB FOLD WATER-RESISTIVE BARRIER HEADER BY
HEADER BY DOWN OVER FLEXIBLE FLASHING OTHERS
FOLD WATER-RESISTIVE BARRIER OTHERS
DOWN OVER FLEXIBLE FLASHING
FLEXIBLE FLASHING OVER HEAD
FLEXIBLE FLASHING OVER HEAD FLASHING
FLASHING

WINDOW TRIM SEALANT


WINDOW TRIM SEALANT
LOW EXPANDING FOAM OR
LOW EXPANDING FOAM OR APPLY BACKER ROD W/
APPLY BACKER ROD W/ SEALANT 2"-4" LAP AT
SEALANT
HORIZONTAL
APPLY SEALANT @ SIDES AND TOP JOINTS
APPLY SEALANT @ SIDES AND TOP ONLY AND NAIL FLANGE
GALVANIZED FLASHING - IF
GALVANIZED FLASHING - IF ONLY AND NAIL FLANGE
REQUIRED BY WINDOW
REQUIRED BY WINDOW MANUFACTURER
MANUFACTURER

D
4"-6" LAP AT VERTICAL ON
JOINTS EY
.) B P.)
N
SECTION VIEW SECTION VIEW CORNER BOARDS PER (6"
9" RNE
MI (TY
R
BUILDER, TYP. CO

WINDOW HEAD WINDOW HEAD INSIDE / OUTSIDE CORNER DETAIL

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


0101C 0101D 0103A
HARDBOARD SIDING W/ TRIM SCALE: 3" = 1'-0" SIDING W/ TRIM SCALE: 3" = 1'-0" W/ NON-PLASTIC BUILDING PAPER SCALE: NTS

PHONE: 303-770-8300
SEALANT SEALANT

LOW EXPANDING FOAM - DO NOT LOW EXPANDING FOAM -


COMPLETELY FILL VOID AT SILL TO DO NOT COMPLETELY
ALLOW FOR DRAINAGE OR APPLY FILL VOID AT SILL TO
BACKER ROD W/ SEALANT ALLOW FOR DRAINAGE
OR APPLY BACKER ROD PLASTIC
W/ SEALANT HOUSEWRAP
1/4" GAP W/ BACKER ROD AND 1/4" GAP W/ BACKER ROD AND
SEALANT SEALANT

MINIMUM 12"
APPLY SEALANT @ CORNERS AND WINDOW SILL APPLY SEALANT @ CORNERS AND WINDOW SILL OVERLAP OF
WRB @ INSIDE
NAIL FLANGE NAIL FLANGE
CORNER
FLEXIBLE MEMBRANE SILL FLASHING FLEXIBLE MEMBRANE SILL
WINDOW TRIM (EXTEND FLASHING BEYOND WINDOW TRIM FLASHING (EXTEND FLASHING
VERTICAL SIDE JAMB) BEYOND VERTICAL SIDE
JAMB)
1/4" REVEAL BETWEEN
TRIM AND PANEL
1/8" GAP W/ SEALANT

GALVANIZED FLASHING
HORIZONTAL LAP SIDING
WATER-RESISTIVE BARRIER - PER WATER-RESISTIVE BARRIER -
HARDBOARD PANEL SIDING PER
BUILDING CODE PER BUILDING CODE
BUILDER

PROVIDE FURRING STRIPS, MIN. 3 8"


THICK, 1 12" WIDE, BETWEEN
WATER-RESISTIVE BARRIER & 6" LAP AT
HARDBOARD PANEL SIDING. HORIZONTAL
INSTALL PER MANUFACTURER'S JOINTS
RECOMMENDATIONS. EXTERIOR SHEATHING EXTERIOR SHEATHING

TAPE ALL SEAMS OF BUILDING


4"-6" LAP AT VERTICAL WRAP PER MANUFACTURER'S
JOINTS RECOMMENDATIONS, EXCEPT
SECTION VIEW SECTION VIEW CORNER BOARDS PER
@ HORIZONTAL TERMINATIONS
WHICH ARE INTENDED TO WEEP.
BUILDER, TYP.

0109D
WINDOW SILL 0109A
WINDOW SILL 0103B
INSIDE / OUTSIDE CORNER DETAIL
HARDBOARD SIDING W/ TRIM SCALE: 3" = 1'-0" SIDING W/ TRIM SCALE: 3" = 1'-0" W/ PLASTIC HOUSE WRAPS SCALE: NTS

PROVIDE FURRING STRIPS, MIN. 3 8"


THICK, 1 12" WIDE, BETWEEN
WATER-RESISTIVE BARRIER & EXTERIOR SHEATHING
HARDBOARD PANEL SIDING.
INSTALL PER MANUFACTURER'S SEALANT
RECOMMENDATIONS.
WATER-RESISTIVE BARRIER
- PER BUILDING CODE
EXTERIOR SHEATHING
WATER-RESISTIVE BARRIER LOW EXPANDING FOAM OR
SEALANT - PER BUILDING CODE APPLY BACKER ROD W/
SEALANT
LOW EXPANDING FOAM OR
APPLY BACKER ROD W/
SEALANT FLEXIBLE MEMBRANE SILL FLASHING
(EXTEND 6" ABOVE TOP OF SILL)

FLEXIBLE MEMBRANE SILL


FLASHING (EXTEND 6"
ABOVE TOP OF SILL)

APPLY SEALANT @ SIDES AND TOP


ONLY AND NAIL FLANGE

APPLY SEALANT @ SIDES AND TOP


ONLY AND NAIL FLANGE JAMB FLASHING WILL BE
APPLIED OVER THE FACE OF
THE INTEGRAL MOUNTING FLANGE
JAMB FLASHING WILL BE
APPLIED OVER THE FACE OF 1/4" GAP W/ BACKER ROD AND
THE INTEGRAL MOUNTING FLANGE SEALANT

1/4" GAP W/ BACKER ROD AND WINDOW TRIM


SEALANT

WINDOW TRIM
1/4" GAP W/ SEALANT
1/4" GAP W/ SEALANT
HORIZONTAL LAP SIDING
HARDBOARD PANEL SIDING PER
BUILDER
PLAN VIEW PLAN VIEW
FURRING STRIP

0105D
WINDOW JAMB 0105A
WINDOW JAMB
HARDBOARD SIDING W/ TRIM SCALE: 3" = 1'-0" SIDING W/ TRIM SCALE: 3" = 1'-0"
©
SECTION VIEW INSULATION SUFFICIENT TO FILL
SECTION VIEW EXTERIOR SHEATHING
Godden|Sudik
WALL CAVITY
EXTERIOR SHEATHING A R C H I T E C T S
INSULATION SUFFICIENT TO FILL HORIZONTAL LAP SIDING
HORIZONTAL LAP SIDING WALL CAVITY SEE WHAT COULD BE
PER BUILDER
WATER-RESISTIVE BARRIER - PER
BUILDING CODE WATER-RESISTIVE BARRIER -
EXTERIOR SHEATHING GYP BD WITH CONTINUOUS SEALANT AT PER BUILDING CODE - LAP WRB OVER
BOTTOM OF FRAMED WALL GALVANIZED FLASHING
PRESSURE TREATED SILL PLATE HORIZONTAL LAP SIDING
WATER-RESISTIVE BARRIER - PER
BUILDING CODE FINISHED FLOOR
STARTER STRIP

1/4" GAP MIN.


GYP BD WITH CONTINUOUS SEALANT AT BETWEEN FLASHING AND SIDING
TOP OF FOUNDATION WALL FLOOR SHEATHING

SILL SEAL
GALVANIZED FLASHING
OPTIONAL INSULATION
1/2" EXPANSION AND GYP BD PER BUILDER STARTER STRIP
MATERIAL

FLOOR JOIST CONCRETE PATIO/STEPS PER GRADE W/ HEADER, RE:


FINISHED FLOOR
STARTER STRIP TURNED DOWN EDGE, RE: STRUCTURAL. STRUCTURAL
SLOPE 1/4" PER FOOT

2" MIN.
CONCRETE SLAB ON GRADE
BETWEEN INSULATION AT RIM JOIST
FLASHING AND SIDING CAVITY PER ENERGY REPORT 1/4" GAP MIN. BETWEEN
FLASHING AND SIDING

RIM JOIST GALVANIZED FLASHING, TURN UP WALL MIN.


CONCRETE PATIO W/ TURNED 2" AND LAP W/ WRB. PAINT TO MATCH
DOWN EDGE, SLOPE 1/4" PER FOOT, ADJACENT MATERIALS, TYP.

2" MIN.
RE: STRUCTURAL
1/2" EXPANSION JOINT

8" MIN.
AND SEALANT

6" MIN.
PRESSURE TREATED
SILL PLATE GARAGE HEADER TRIM, RE:
GALVANIZED FLASHING SET IN ELEVATIONS. SPANS ENTIRE GARAGE,
SEALANT & TURNED DOWN INTO INCLUDING SIDE TRIM PIECES
1/4" KERF
DOOR HEAD HT.
POROUS FILL
1/2" EXPANSION JOINT RE: ELEVATIONS

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


AND SEALANT
SILL SEAL
CONCRETE HAUNCH / WING
BASEMENT WALL INSULATION WALLS PER STRUCTURAL
GALVANIZED FLASHING

DAMPPROOFING, EXTEND
FULL DEPTH OF GARAGE DOOR TRIM, TYP.
CONCRETE

PHONE: 303-770-8300
APPLY SELF-ADHERING, SELF-SEALING
ADHERED BITUMIN
FLASHING BEHIND WRB AND FLASHING
MEMBRANE BEHIND METAL
AND INTO ROUGH OPENING. TURN UP
FLASHING TO COVER
WALL MIN. 8". (FLASHING CANNOT BE
SHEATHING. START MIN. 4"
LEFT PERMANENTLY EXPOSED)
ABOVE FLOOR DECK

CONTINUOUS
DAMPPROOFING, EXTEND
GALVANIZED FLASHING GARAGE DOOR TRACK BEYOND.
TO TOP OF CONCRETE
OVER MEMBRANE, INSTALL PER MANUFACTURER'S
WALL- MATCH COLOR OF
RIGID INSULATION @ FOUNDATION START BEHIND REQUIREMENTS WITH APPROPRIATE
CONCRETE
PERIMETER. USE EXTRUDED POLYSTYRENE GALVANIZED FLASHING
(XPS). BELOW SHEATHING AND SECTION VIEW HARDWARE AND WEATHER STRIPPING

EXTEND DOWN
VAPOR BARRIER / RADON MITIGATION, RUN FOUNDATION WALL MIN.
BENEATH SLAB AND EXTEND DOWN 4"
FOUNDATION WALL, AS REQUIRED BY LOCAL
MUNICIPALITIES

BASE OF WALL @ WALKOUT BASE OF WALL @ FRONT PORCH GARAGE DOOR HEADER
0116A 0123A 0114A
SIDING SCALE: 3" = 1'-0" SIDING SCALE: 3" = 1'-0" SIDING W/ TRIM SCALE: 3" = 1'-0"

INSULATION SUFFICIENT TO FILL


WALL CAVITY LINE OF SIDING OR HARDBOARD BEYOND
SECTION VIEW HORIZONTAL LAP SIDING
SECTION VIEW SILL PAN WITH REAR & SIDE EDGES
SLIDING GLASS DOOR PER EXTERIOR SHEATHING
TURNED UP. ALL CORNERS SHALL BE
BUILDER SEALED AND WATERTIGHT. LAP OVER HARDBOARD PANEL SIDING PER
EXTERIOR SHEATHING FLASHING TO ALLOW DRAINAGE BUILDER

PRESSURE TREATED SILL PLATE LINE OF END DAM WATER-RESISTIVE BARRIER -


WATER-RESISTIVE BARRIER - PER FLASHING THRESHOLD BY DOOR PER BUILDING CODE - LAP WRB OVER
BUILDING CODE MANUFACTURER. LAP TRIM AT STEP GALVANIZED FLASHING
CONTINUOUS SEALANT DOWN AND SEAL
PROVIDE FURRING STRIPS, MIN. 3 8"
TRIM BOARD - INSTALL OVER SPACERS
GYP BD WITH CONTINUOUS SEALANT FINISH FLOOR OR DRAINAGE MAT BEHIND TO PROVIDE THICK, 1 12" WIDE, BETWEEN
AT TOP OF FOUNDATION WALL WATER-RESISTIVE BARRIER &
DRAINAGE/AIR SPACE.
HARDBOARD PANEL SIDING.
ATTACH W/ SCREWS THROUGH
INSTALL PER MANUFACTURER'S
PRE-DRILLED HOLES IN FRONT FACE OF
SILL SEAL RECOMMENDATIONS.
THRESHOLD

RE: PLANS
STARTER STRIP
1/2" EXPANSION OPTIONAL INSULATION
MATERIAL GALVANIZED METAL THROUGH WALL AND GYP BD PER BUILDER
1/4" GAP MIN.
BETWEEN FLASHING AND SIDING FLASHING SET IN BED OF SEALANT,
FINISHED FLOOR LAPPED BY AND SEALED BENEATH PAN HEADER, RE:
FLASHING STRUCTURAL
CONCRETE SLAB ON GRADE GALVANIZED FLASHING

GALVANIZED FLASHING
TURNED DOWN INTO 1/4"
KERF FLEXIBLE FLASHING APPLIED
POROUS FILL
OVER THE GALVANIZED
FINISHED GRADE - TOP OF
FLASHING
LANDSCAPE MATERIAL - SLOPE
GRADE AWAY FROM FOUNDATION
A MIN. 5% WITHIN THE FIRST 10',
8" MIN.

OR AS REQUIRED PER THE 1/4" GAP MIN. BETWEEN


6" MIN.

6" MIN.

GRADING PLAN AND SOILS FLASHING AND SIDING


REPORT.
GALVANIZED FLASHING, TURN UP WALL
MIN. 2" AND LAP W/ WRB

1
2" EXPANSION
POROUS FILL MATERIAL

DAMPPROOFING, EXTEND TO CONCRETE SLAB DOOR HEAD HT.


TOP OF CONCRETE WALL - ON GRADE, RE: RE: ELEVATIONS
MATCH COLOR OF CONCRETE STRUCTURAL

CONCRETE PATIO W/ TURNED


DOWN EDGE, SLOPE 1/4" PER FOOT,
LANDSCAPE RE: STRUCTURAL
MATERIAL GALVANIZED FLASHING
ADHERED BITUMIN MEMBRANE,
SET INTO ROUGH OPENING,
COMPACTED SUBGRADE BENEATH SILL PAN, AND TURNED GARAGE DOOR TRIM, TYP.
DOWN TO PATIO
APPLY SELF-ADHERING, SELF-SEALING
1/2" EXPANSION JOINT AND
FLASHING BEHIND WRB AND FLASHING
FOUNDATION WALL SEALANT
AND INTO ROUGH OPENING. TURN UP
RIGID INSULATION @ FOUNDATION WALL MIN. 8". (FLASHING CANNOT BE
PERIMETER. USE EXTRUDED LEFT PERMANENTLY EXPOSED)
POLYSTYRENE (XPS).
GARAGE DOOR TRACK BEYOND. INSTALL
RIGID INSULATION @ FOUNDATION DAMPPROOFING, EXTEND PER MANUFACTURER'S REQUIREMENTS
PERIMETER. USE EXTRUDED POLYSTYRENE TO TOP OF CONCRETE WITH APPROPRIATE HARDWARE AND
(XPS). WALL- MATCH COLOR OF
VAPOR BARRIER / RADON MITIGATION, RUN WEATHER STRIPPING
VAPOR BARRIER / RADON MITIGATION, RUN BENEATH SLAB AND EXTEND DOWN
FOUNDATION WALL, AS REQUIRED BY LOCAL
CONCRETE
SECTION VIEW
BENEATH SLAB AND EXTEND DOWN
FOUNDATION WALL, AS REQUIRED BY LOCAL MUNICIPALITIES
MUNICIPALITIES

BASE OF WALL @ WALKOUT BASE OF WALL @ PATIO / PORCH GARAGE DOOR HEADER
0117E 0120B 0114C
SIDING SCALE: 3" = 1'-0" @ SLIDING GLASS DOOR SCALE: 3" = 1'-0" HARDBOARD SIDING W/ TRIM SCALE: 3" = 1'-0"
©
SILL PAN FLASH WITH REAR & SIDE
SLIDING GLASS DOOR PER EDGES TURNED UP. ALL CORNERS

SECTION VIEW
BUILDER SHALL BE SEALED AND WATERTIGHT. Godden|Sudik
LAP OVER FLASHING TO ALLOW
DRAINAGE
SECTION VIEW A R C H I T E C T S
GALVANIZED SILL PAN
FLASH BEYOND SECTION VIEW SEE WHAT COULD BE

CONTINUOUS SEALANT BACKER ROD AND SEALANT


GYP BD WITH CONTINUOUS SEALANT AT
TRIM BOARD - INSTALL OVER SPACERS HORIZONTAL LAP SIDING BOTTOM OF FRAMED WALL INSULATION SUFFICIENT TO FILL
FINISH FLOOR OR DRAINAGE MAT BEHIND TO PROVIDE WALL CAVITY
DRAINAGE/AIR SPACE
EXTERIOR SHEATHING FINISHED FLOOR
OPTIONAL BATT INSULATION
PER BUILDER
WATER-RESISTIVE BARRIER - PER
FLOOR SHEATHING BUILDING CODE
OPTIONAL GYP BD PER BUILDER
GALVANIZED METAL THROUGH WALL FLOOR SHEATHING
WITH CONTINUOUS SEALANT AT
FLASHING SET IN BED OF SEALANT,
TOP OF FOUNDATION WALL HORIZONTAL LAP SIDING
LAPPED BY AND SEALED BENEATH PAN
FLASHING
EXTERIOR SHEATHING
FLOOR JOIST
CONCRETE PATIO/STEPS PER GRADE W/ PRESSURE TREATED SILL
TURNED DOWN EDGE, RE: STRUCTURAL. PLATE WOOD FLOOR JOIST WATER-RESISTIVE BARRIER - PER
SLOPE 1/4" PER FOOT BUILDING CODE

MIN
1/2"
STARTER STRIP
SILL SEAL RIM JOIST
RIM JOIST 1/4" GAP MIN.
GALVANIZED FLASHING BETWEEN FLASHING AND SIDING
TURNED DOWN INTO 1/4"
INSULATION SUFFICIENT TO FILL KERF 1/2" EXPANSION
RIM JOIST CAVITY MATERIAL
INSULATION SUFFICIENT TO FILL
GALVANIZED FLASHING
RIM JOIST CAVITY

STARTER STRIP
PRESSURE TREATED FINISHED GRADE - TOP OF
SILL PLATE LANDSCAPE MATERIAL - SLOPE
PRESSURE TREATED SILL 1/4" GAP MIN.
GRADE AWAY FROM FOUNDATION
PLATE BETWEEN FLASHING AND SIDING

4" MIN.
A MIN. 5% WITHIN THE FIRST 10',
CONCRETE SLAB ON GRADE,
OR AS REQUIRED PER THE

8" MIN.
SLOPE PER GRADE

6" MIN.
GRADING PLAN AND SOILS
1/2" EXPANSION JOINT AND REPORT. GALVANIZED FLASHING
SEALANT

ADHERED BITUMIN MEMBRANE,

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SILL SEAL FINISHED GRADE - TOP OF
SET INTO ROUGH OPENING,
LANDSCAPE MATERIAL - SLOPE
BENEATH SILL PAN, AND TURNED SILL SEAL
BASEMENT WALL GRADE AWAY FROM FOUNDATION
DOWN TO COVER SHEATHING
INSULATION A MIN. 5% WITHIN THE FIRST 10',

8" MIN.
DAMPPROOFING, EXTEND TO BASEMENT WALL OR AS REQUIRED PER THE

6" MIN.
TOP OF CONCRETE WALL - INSULATION GRADING PLAN AND SOILS
CONTINUOUS GALVANIZED
FLASHING OVER MEMBRANE, START GRAY COLOR TO MATCH REPORT.
BEHIND WEEP SCREED AND EXTEND CONCRETE
DOWN FOUNDATION WALL MIN. 4"

PHONE: 303-770-8300
LANDSCAPE
MATERIAL
FOUNDATION WALL

CONCRETE HAUNCH / WING DAMPPROOFING, EXTEND TO


WALLS PER STRUCTURAL TOP OF CONCRETE WALL -
GRAY COLOR TO MATCH
DAMPPROOFING, EXTEND CONCRETE
FULL DEPTH OF
COMPACTED SUBGRADE LANDSCAPE
CONCRETE
MATERIAL
FOUNDATION WALL

COMPACTED SUBGRADE

SLIDING GLASS DOOR @ PATIO / BASE OF WALL @ GARAGE /


WOOD JOIST FLOOR SYSTEM FOUNDATION WALL BASE OF WALL @ GRADE
0121B 0119 0118B
@ SLIDING GLASS DOOR SCALE: 3" = 1'-0" SIDING @ GRADE SCALE: 3" = 1'-0" SIDING SCALE: 3" = 1'-0"

LINE OF SIDING OR HARDBOARD BEYOND


DOOR AND THRESHOLD PER
BUILDER. THRESHOLD TO LAP INSULATION SUFFICIENT TO FILL
AND SEAL TOP OF TRIM PIECE SILL PAN FLASH WITH REAR & SIDE
WALL CAVITY
BELOW EDGES TURNED UP. ALL CORNERS
GYP BD WITH CONTINUOUS SEALANT AT GYP BD WITH CONTINUOUS SEALANT AT
SHALL BE SEALED AND WATERTIGHT. INSULATION SUFFICIENT TO FILL EXTERIOR SHEATHING
LINE OF END DAM FLASHING BOTTOM OF FRAMED WALL BOTTOM OF FRAMED WALL
LAP OVER FLASHING TO ALLOW WALL CAVITY HORIZONTAL LAP SIDING OR
CONTINUOUS SEALANT DRAINAGE
FINISHED FLOOR FINISHED FLOOR HARDBOARD SIDING
FINISHED FLOOR
BACKER ROD AND SEALANT WATER-RESISTIVE BARRIER - PER
TRIM BOARD - INSTALL OVER SPACERS FLOOR SHEATHING BUILDING CODE
OR DRAINAGE MAT BEHIND TO PROVIDE
DRAINAGE/AIR SPACE FLEXIBLE FLASHING APPLIED
FLOOR SHEATHING FLOOR SHEATHING OVER THE GALVANIZED
FLASHING
GALVANIZED THROUGH WALL FLASHING
WOOD FLOOR JOIST
RE: PLANS

SET IN BED OF SEALANT, LAPPED BY STARTER STRIP


AND SEALED BENEATH PAN FLASHING GYP BD W/ CONTINUOUS SEALANT AT

2" (MIN.)
BOTTOM OF WALL
RIM JOIST
FLOOR JOIST WOOD FLOOR JOIST
CONCRETE PATIO/STEPS PER GRADE W/ BLOCKING
TURNED DOWN EDGE, RE: STRUCTURAL.
SLOPE 1/4" PER FOOT
MIN

1/4" GAP MIN.


1/2"

RIM JOIST BETWEEN FLASHING AND TRIM

INSULATION SUFFICIENT TO FILL GALVANIZED FLASHING


RIM JOIST GALVANIZED FLASHING RIM JOIST CAVITY
TURNED DOWN INTO 1/4" VARIES TRIM
INSULATION AT RIM JOIST KERF INSULATION AT RIM JOIST
CAVITY PER ENERGY REPORT
RE: PLAN PRESSURE TREATED SILL
CAVITY PER ENERGY
PLATE
REPORT

SILL SEAL
PRESSURE TREATED PRESSURE TREATED SILL
SILL PLATE PLATE BASEMENT WALL
INSULATION

1/2" EXPANSION JOINT AND SOFFIT BOARD CONTINUOUS SEALANT


SEALANT 1/2" EXPANSION MATERIAL

MIN.
1/4"
SILL SEAL ADHERED BITUMIN MEMBRANE, SILL SEAL
CONCRETE SLAB TRIM W/ 1/8" GAP
SET INTO ROUGH OPENING,

MIN.
AND SEALANT

8"
BASEMENT WALL INSULATION BENEATH SILL PAN, AND TURNED BASEMENT WALL
DOWN TO COVER SHEATHING INSULATION

CONTINUOUS GALVANIZED
FLASHING OVER MEMBRANE, START DAMPPROOFING, EXTEND TO
BEHIND WEEP SCREED AND EXTEND TOP OF CONCRETE WALL -
DOWN FOUNDATION WALL MIN. 4" GRAY COLOR TO MATCH
CONCRETE

DAMPPROOFING, EXTEND
FULL DEPTH OF
CONCRETE
LANDSCAPE
MATERIAL
CONCRETE HAUNCH / WING FOUNDATION WALL
WALLS PER STRUCTURAL

COMPACTED SUBGRADE

SECTION VIEW
SECTION VIEW SECTION VIEW
BASE OF WALL
@ FRONT DOOR / PORCH BASE OF INT. WALL / GARAGE CANTILEVER @ GRADE
0122B 0118C 0112A
SCALE: 3" = 1'-0" SIDING SCALE: 3" = 1'-0" SIDING W/ TRIM SCALE: 3" = 1'-0"
©
SECTION VIEW SECTION VIEW EXTERIOR SHEATHING WATER-RESISTIVE BARRIER WITH A Godden|Sudik
PERFORMANCE AT LEAST EQUIVALENT TO 2
MORTAR SETTING BED LAYERS OF GRADE D PAPER - PER BUILDING
A R C H I T E C T S
EXTERIOR SHEATHING CODE SEE WHAT COULD BE
LATH W/ SCRATCH COAT EXTERIOR SHEATHING
INSULATION SUFFICIENT TO FILL
MORTAR SETTING BED LATH W/ SCRATCH
WALL CAVITY ADHERED MASONRY VENEER
SEALANT COAT
LATH W/ SCRATCH COAT PER BUILDER
GYP BD WITH CONTINUOUS SEALANT AT ADHERED MASONRY VENEER WATER-RESISTIVE BARRIER WITH A LOW EXPANDING FOAM OR
BOTTOM OF FRAMED WALL PER BUILDER PERFORMANCE AT LEAST EQUIVALENT TO 2 APPLY BACKER ROD W/
OPTIONAL BATT INSULATION LAYERS OF GRADE D PAPER - PER BUILDING
WATER-RESISTIVE BARRIER WITH A SEALANT
FINISHED FLOOR PER BUILDER CODE - LAP WRB OVER WEEP SCREED
PERFORMANCE AT LEAST EQUIVALENT TO 2
LAYERS OF GRADE D PAPER - PER BUILDING FLEXIBLE MEMBRANE SILL
CODE - LAP WRB OVER WEEP SCREED FLASHING (EXTEND 6" ABOVE TOP
OPTIONAL GYP BD PER BUILDER OF SILL)
WITH CONTINUOUS SEALANT AT
FLOOR SHEATHING WEEP SCREED (SHALL BE PLACED A MIN. OF 4" TOP OF FOUNDATION WALL
ABOVE THE FINISHED GRADE OR 2" ABOVE PAVED
SURFACES AND SHALL BE A TYPE THAT WILL
APPLY SEALANT @ SIDES AND TOP
ALLOW TRAPPED WATER TO DRAIN TO THE
ONLY AND NAIL FLANGE
EXTERIOR OF THE BUILDING) - PER BUILDING PRESSURE TREATED SILL
CODE PLATE
JAMB FLASHING WILL BE
FLOOR JOIST CONCRETE PATIO/STEPS PER GRADE W/ APPLIED OVER THE FACE OF
TURNED DOWN EDGE, RE: STRUCTURAL. WEEP SCREED (SHALL BE PLACED A MIN. OF 4" THE INTEGRAL MOUNTING FLANGE
SLOPE 1/4" PER FOOT SILL SEAL

2" MIN.
ABOVE THE FINISHED GRADE OR 2" ABOVE PAVED
1/4" GAP W/ BACKER ROD AND
RIM JOIST SURFACES AND SHALL BE A TYPE THAT WILL
SEALANT
ALLOW TRAPPED WATER TO DRAIN TO THE MORTAR SETTING BED
1/2" EXPANSION EXTERIOR OF THE BUILDING) - PER BUILDING
MATERIAL CODE TRIM OVER BACKER CASING BEAD ADHERED MASONRY
BOARD VENEER PER BUILDER
INSULATION SUFFICIENT TO FILL 1/2" GAP W/ BACKER ROD AND
RIM JOIST CAVITY SEALANT

FINISHED GRADE - TOP OF


LANDSCAPE MATERIAL - SLOPE

4" MIN.
PRESSURE TREATED GRADE AWAY FROM FOUNDATION
CONCRETE SLAB ON GRADE,
A MIN. 5% WITHIN THE FIRST 10',

8" MIN.
SILL PLATE SLOPE PER GRADE

6" MIN.
OR AS REQUIRED PER THE
PLAN VIEW

4" MIN.
GRADING PLAN AND SOILS
REPORT.

1/2" EXPANSION JOINT


WINDOW JAMB

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


AND SEALANT
0405A
ADHERED MASONRY VENEER W/ TRIM SCALE: 3" = 1'-0"
SILL SEAL
CONCRETE HAUNCH / WING
BASEMENT WALL DAMPPROOFING, EXTEND TO
WALLS PER STRUCTURAL
INSULATION TOP OF CONCRETE WALL -
MATCH COLOR OF CONCRETE
DAMPPROOFING, EXTEND

PHONE: 303-770-8300
FULL DEPTH OF
LANDSCAPE
CONCRETE MATERIAL
ADHERED BITUMIN FOUNDATION WALL
MEMBRANE BEHIND METAL SEALANT
FLASHING TO COVER
SHEATHING. START MIN. 4"
ABOVE FLOOR DECK
APPLY SEALANT @ CORNERS AND
CONTINUOUS COMPACTED SUBGRADE NAIL FLANGE LOW EXPANDING FOAM - DO NOT
GALVANIZED FLASHING COMPLETELY FILL VOID AT SILL TO
OVER MEMBRANE, 1/4" GAP W/ BACKER ROD AND SEALANT ALLOW FOR DRAINAGE OR APPLY
START BEHIND WEEP BACKER ROD W/ SEALANT
SCREED AND EXTEND
DOWN FOUNDATION GALVANIZED FLASHING FOR TOP
WALL MIN. 4" EDGE PROTECTION OF TRIM AS
REQUIRED, TYP.

TRIM BOARD PER ELEVATION

BASE OF WALL @ PATIO / PORCH BASE OF WALL @ GARAGE 1/2" GAP MIN.
BETWEEN TRIM AND FLASHING FLEXIBLE MEMBRANE SILL
0413B 0414 FLASHING (EXTEND
ADHERED MASONRY VENEER SCALE: 3" = 1'-0" ADHERED MASONRY VENEER @ GRADE SCALE: 3" = 1'-0"
FLASHING BEYOND VERTICAL
GALVANIZED FLASHING SIDE JAMB)

ADH. MASONRY TRIM CAP


W/ DRIP EDGE (PER. MFG.),
MIN. SLOPE OF 15°

CASING BEAD WATER-RESISTIVE BARRIER WITH A


PERFORMANCE AT LEAST
EQUIVALENT TO 2 LAYERS OF
MORTAR SETTING BED GRADE D PAPER - PER BUILDING
SECTION VIEW 2" SUPPORT ANGLE BEHIND LATH -
CODE

FASTEN AS REQUIRED
EXTERIOR SHEATHING
INSULATION SUFFICIENT TO FILL LATH W/ SCRATCH COAT
MORTAR SETTING BED EXTERIOR SHEATHING
WALL CAVITY
LATH W/ SCRATCH COAT ADHERED MASONRY VENEER
PER BUILDER
GYP BD WITH CONTINUOUS SEALANT AT ADHERED MASONRY VENEER CORROSION RESISTANT LATH
BOTTOM OF FRAMED WALL PER BUILDER MORTAR SETTING BED FASTNER

FINISHED FLOOR WATER-RESISTIVE BARRIER WITH A


PERFORMANCE AT LEAST EQUIVALENT TO 2
SECTION VIEW
LAYERS OF GRADE D PAPER - PER BUILDING
CODE - LAP WRB OVER WEEP SCREED

FLOOR SHEATHING 0403D


WINDOW SILL
ADHERED MASONRY VENEER SCALE: NTS
W/ TRIM BOARD & ADH. MASONRY CAP

FLOOR JOIST

RIM JOIST

INSULATION SUFFICIENT TO FILL


RIM JOIST CAVITY
WEEP SCREED (SHALL BE PLACED A MIN. OF 4"
ABOVE THE FINISHED GRADE OR 2" ABOVE PAVED
SURFACES AND SHALL BE A TYPE THAT WILL
PRESSURE TREATED ALLOW TRAPPED WATER TO DRAIN TO THE
SILL PLATE EXTERIOR OF THE BUILDING) - PER BUILDING
CODE

FINISHED GRADE - TOP OF


LANDSCAPE MATERIAL - SLOPE
SILL SEAL
GRADE AWAY FROM FOUNDATION
A MIN. 5% WITHIN THE FIRST 10',
8" MIN.

6" MIN.

BASEMENT WALL OR AS REQUIRED PER THE


4" MIN.

INSULATION GRADING PLAN AND SOILS


REPORT.

DAMPPROOFING, EXTEND TO
TOP OF CONCRETE WALL -
MATCH COLOR OF CONCRETE

LANDSCAPE
MATERIAL
FOUNDATION WALL

COMPACTED SUBGRADE

BASE OF WALL @ GRADE


0413A
ADHERED MASONRY VENEER SCALE: 3" = 1'-0"
©
ADH. MASONRY APPLICATION
TERMINATING IN VERTICAL WEEP
SCREED, SIM. TO STUCCO APPLICATION
WATER-RESISTIVE BARRIER WITH A
PERFORMANCE AT LEAST EQUIVALENT TO 2
LAYERS OF GRADE D PAPER - PER BUILDING
CODE - LAP WRB OVER WEEP SCREED
EXTERIOR SHEATHING Godden|Sudik
LAP SIDING, RE: ELEVATIONS WATER-RESISTIVE BARRIER - PER A R C H I T E C T S
BUILDING CODE SEE WHAT COULD BE
STARTER STRIP
1/4" GAP MIN. BETWEEN HORIZONTAL LAP SIDING
FLASHING AND SIDING
METAL COUNTER FLASHING W/ STARTER STRIP
HEMMED/DRIP EDGE KICKOUT
1/4" GAP MIN.
CAULK BETWEEN FLASHING AND TRIM BETWEEN FLASHING AND SIDING
BOARD

GALVANIZED METAL HEAD WALL FLASHING EXTENDED


GALVANIZED FLASHING TURN UP
OVER ROWLOCK SILL A MIN. 2" AND A MIN. 6" UPWARD
WALL MIN. 2" AND LAP W/ WRB
LEG BEHIND WRB

SILL CAP W/ DRIP EDGE (SLOPED FOR


DRAINAGE AT MIN. 15°, TRIM VARIES PER
ELEVATIONS) PER MFG.

TERMINATE SIDING
A MIN. OF 1/2" OFF
OF FLASHING
2" SUPPORT ANGLE BEHIND LATH -
FASTEN AS REQUIRED

VERTICAL WEEP SCREED

1/2" EXPANSION JOINT,


APPLY BACKER ROD AND SEALANT ADHERED MASONRY APPLICATION
TRIM
TERMINATING IN WEEP SCREED
1/8" GAP W/ SEALANT
VERTICAL TRIM BOARD, RE: EXTERIOR SHEATHING
ELEVATIONS
HORIZONTAL LAP SIDING
CAULK JOINT, TYP. WATER RESISTIVE BARRIER
WITH A PERFORMANCE AT
LEAST EQUIVALENT TO 2
WATER RESISTIVE BARRIER LAYERS OF GRADE D PAPER - PER
BUILDING CODE

EXTERIOR SHEATHING SECTION VIEW


LAP SIDING PER BUILDER
SECTION VIEW
PLAN VIEW

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


0510
INSIDE CORNER 0504A
SIDING TO ADH. MASONRY 0104A
SIDING TO SIDING
SIDING W/ TRIM TO ADHERED MASONRY VENEER SCALE: 3" = 1'-0" SIDING W/ TRIM TO ADH. MASONRY SCALE: 3" = 1'-0" SIDING W/ TRIM TO SIDING SCALE: 3" = 1'-0"

PHONE: 303-770-8300
VERTICAL J-CHANNEL FOR TERMINATION OF PROVIDE FURRING STRIPS, MIN. 3 8"
LAP SIDING APPLICATION W/O VERTICAL THICK, 1 12" WIDE, BETWEEN
TRIM WATER-RESISTIVE BARRIER &
ADH. MASONRY APPLICATION TERMINATING HARDBOARD PANEL SIDING.
IN VERTICAL WEEP SCREED, SIM. TO INSTALL PER MANUFACTURER'S
STUCCO APPLICATION RECOMMENDATIONS.

WATER-RESISTIVE BARRIER WITH A EXTERIOR SHEATHING


PERFORMANCE AT LEAST
EQUIVALENT TO 2 LAYERS OF GRADE WATER-RESISTIVE BARRIER - PER
D PAPER - PER BUILDING CODE - LAP BUILDING CODE
WRB OVER WEEP SCREED
12" MIN. VERTICAL
HARDBOARD PANEL SIDING PER
WRB LAP
BUILDER

1/4" GAP MIN.


BETWEEN FLASHING AND SIDING

GALVANIZED FLASHING TURN UP


MIN. 12" VERTICAL LAP OF WATER WALL MIN. 2" AND LAP W/ WRB
RESISTIVE BARRIER @ THE
INSIDE CORNER

2X2 HARDBOARD TRIM W/ 1/8"


GAP W/ SEALANT JOINT BETWEEN
SIDING, TYP.
TRIM

EXTERIOR SHEATHING 1/8" GAP W/ SEALANT

HORIZONTAL LAP SIDING


WATER-RESISTIVE BARRIER - PER
1/2" EXPANSION JOINT,
BUILDING CODE
APPLY BACKER ROD AND
SEALANT

HORIZONTAL LAP SIDING VERTICAL TRIM BOARD FOR TERMINATION


OF LAP SIDING APPLICATION
PLAN VIEW SECTION VIEW
CAULK JOINT, TYP.
PLAN VIEW
LAP SIDING PER BUILDER

0108B
INSIDE CORNER SIDING TO ADH. MASONRY 0101D
SIDING TO SIDING
SIDING W/ TRIM SCALE: NTS 0511A HARDBOARD SIDING W/ TRIM TO SIDING SCALE: 3" = 1'-0"
SIDING W/ TRIM SCALE: 3" = 1'-0"

WATER-RESISTIVE
BARRIER - PER
BUILDING CODE
EXTERIOR SHEATHING

WATER-RESISTIVE BARRIER - PER


EXTERIOR
BUILDING CODE
SHEATHING

MIN. 12" VERTICAL LAP OF WATER HORIZONTAL LAP SIDING


HARDBOARD PANEL
RESISTIVE BARRIER @ THE SIDING PER BUILDER
INSIDE CORNER

DOUBLE LAYER SPLINE OF


WATER-RESISTIVE BARRIER
METAL CORNER APPLIED VERTICALLY, MIN. 6"
1/4" GAP W/ SEALANT
BEYOND CORNER AS
REQUIRED PER
MANUFACTURER
WATER-RESISTIVE BARRIER - PER
CORNER TRIM
BUILDING CODE METAL CORNER

EXTERIOR SHEATHING

HARDBOARD PANEL SIDING PER


BUILDER

PLAN VIEW PLAN VIEW


PLAN VIEW

INSIDE CORNER 0108A


OUTSIDE CORNER OUTSIDE CORNER
0108D SIDING W/ TRIM SCALE: NTS 0108C
SIDING W/ METAL CORNER SCALE: 3" = 1'-0" SIDING W/ METAL CORNER SCALE: NTS
©
: WHEN SPECIAL CONDITIONS EXIST WATER RESISTIVE BARRIER - PER
(STEPPING, NORTH FACING, ETC.) BUILDER TO BUILDER CODE
FIELD VERIFY ICE & WATER SHIELD
: WHEN SPECIAL EXTERIOR SHEATHING
CONDITIONS EXIST (STEPPING, ROOFING MATERIAL
NORTH FACING, ETC.) BUILDER (SHINGLES OVERHANG DRIP
: WHEN SPECIAL CONDITIONS
EXIST (STEPPING, NORTH FACING, ETC.)
TO FIELD VERIFY ICE & WATER
SHIELD
EDGE 1/4" TO 3/4") ICE & WATER MEMBRANE - EXTEND UP WALL SHEATHING MIN. 6"
BEHIND WATER RESISTIVE BARRIER (OR ABOVE HIGHEST
Godden|Sudik
BUILDER TO FIELD VERIFY ICE & WATER ICE & WATER SHIELD DIRECTLY OVER
EXPECTED LEVEL OF SNOW & ICE) AND MIN. 12" HORIZONTALLY A R C H I T E C T S

1/4" GAP
DO NOT
CAULK
SHIELD ALONG ROOF DECK
ROOF SHEATHING - EXTEND FROM THE SEE WHAT COULD BE
EXTERIOR SHEATHING LOWEST EDGES OF ALL ROOF SURFACES GALVANIZED COUNTER FLASHING LAP 2" MIN. OVER STEP
AND OVERLAP FASCIA A MIN OF 2" AND FLASHING W/ DRIP KICK EDGE
WATER RESISTIVE BARRIER, LAP OVER EXTEND UP THE ROOF SLOPE TO A POINT
STEP FLASHING 12 TIGHT FITTED 1X BLOCKING, FLASHING OVER BLOCKING TO BE
ICE & WATER MEMBRANE - AT LEAST 24" INSIDE THE EXTERIOR WALL
NEARLY FLUSH WITH THE EXTERIOR FINISH
EXTEND UP WALL SHEATHING 6" RE: ROOF LINE OF THE BUILDING
BEHIND WATER RESISTIVE LAP SIDING EXTERIOR FINISH PLAN
BARRIER (OR ABOVE HIGHEST MATERIAL GALVANIZED HEAD WALL FLASHING W/ MIN. 8" OVERLAP
EXPECTED LEVEL OF SNOW & IN WATER SHEDDING LAP FASHION AT ROOF SADDLE AND EXTEND
STARTER STRIP

ABOVE DECK
ICE) AND MIN. 12" HORIZ. ALONG UP THE FACE OF THE 1X BLOCKING, PAINT TO MATCH PER BUILDER

4"-6" MIN.
ROOF DECK GALVANIZED FLASHING W/ KICKOUT EDGE ROOFING UNDERLAYMENT OVER DRIP
OVER BLOCKING EDGE FLASHING AND ICE & WATER
ASPHALT SHINGLES BY
SHIELD HO
STEP FLASHING W/ 2-4" LONGER RIZ 8" M BUILDER INSTALLED PER
. (R I MFG.
VERTICAL LEG THAN NORMAL 2" DEEP CORRUGATED INSULATION OO N.
VENT BAFFLES/CHANNELS ROOF SHEATHING PER STRUCTURAL FS INSTRUCTIONS/SPECS
AD

(DO NOT
1/4" GAP
ROOFING UNDERLAYMENT OVER ICE &

CAULK)
ATTACHED TO THE UNDERSIDE OF DL
WATER MEMBRANE E)
ROOF SHEATHING ROOF UNDERLAYMENT OVER
ROOFING MATERIAL ICE & WATER MEMBRANE
GALVANIZED DRIP EDGE FLASHING OVER
FASCIA
2X WOOD RAFTER TAIL

TIGHT FITTED 2X WALL SHEATHING EXTENDING UP


SET HANGING GUTTER BELOW ROOF
BLOCKING, FLASHING OVER TO UNDERSIDE OF ROOF RAFTER
SLOPE LINE (1/2" FOR 7:12 ROOF AND
BLOCKING TO BE NEARLY FLUSH PROVIDE WINDBLOCK BAFFLE
3/4" FOR 5:12 ROOF) TO ALLOW
WITH THE EXTERIOR FINISH INTEGRATIVE WITH VENT BAFFLES OPTIONAL
SNOW AND ICE TO SLIDE CLEAR
PROVIDE BLOCKING TO SECONDARY BASE
RESTRAIN INSULATION FLASHING OVER
ROOF
FASCIA, RE: ELEVS. UNDERLAYMENT
LEDGER AND LINE OF
BLOCKING BEYOND PER 2X SUB FASCIA SET DIRECTLY
SOFFIT BOARD MFG. BELOW ROOF SHEATHING TO HOLD
DOWN
EAVE VENTS AT SOFFIT PANEL OR
SECTION VIEW PERFORATED SOFFIT PANEL PER
BUILDER SECTION VIEW
1/4" BACKER ROD AND SEALANT

ROOF TO WALL @ RAKE HEAD WALL FLASHING

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


WATER RESISTIVE BARRIER
0610A 0602
SIDING SCALE: 3" = 1'-0" HARDBOARD SIDING SCALE: 3" = 1'-0"
FINISH MATERIAL PER BUILDER

SECTION VIEW WATER RESISTIVE BARRIER - PER


: WHEN SPECIAL CONDITIONS EXIST

PHONE: 303-770-8300
(STEPPING, NORTH FACING, ETC.) BUILDER TO BUILDER CODE
: WHEN SPECIAL CONDITIONS EXIST ROOF SHINGLES PER BUILDER
FIELD VERIFY ICE & WATER SHIELD
(STEPPING, NORTH FACING, ETC.) BUILDER TO ROOF FASCIA
FIELD VERIFY ICE & WATER SHIELD EXTERIOR SHEATHING
2X SUB FASCIA SET DIRECTLY
BELOW ROOF SHEATHING TO HOLD ICE & WATER MEMBRANE - EXTEND UP WALL SHEATHING MIN. 6"
DOWN BEHIND WATER RESISTIVE BARRIER (OR ABOVE HIGHEST
CONTINUOUS DRIP EDGE FLASHING, LAP EXPECTED LEVEL OF SNOW & ICE) AND MIN. 12" HORIZONTALLY

1/4" GAP
DO NOT
CAULK
OVER UNDERLAYMENT ALONG ROOF DECK

ROOF UNDERLAYMENT GALVANIZED COUNTER FLASHING LAP 2" MIN. OVER STEP
FLASHING W/ DRIP KICK EDGE

EAVE DETAIL
TIGHT FITTED 1X BLOCKING, FLASHING OVER BLOCKING TO BE
NEARLY FLUSH WITH THE EXTERIOR FINISH
0605A
@ EAVE SCALE: 3" = 1'-0"
GALVANIZED HEAD WALL FLASHING W/ MIN. 8" OVERLAP
IN WATER SHEDDING LAP FASHION AT ROOF SADDLE AND EXTEND
OVERHANG

ABOVE DECK
UP THE FACE OF THE 1X BLOCKING, PAINT TO MATCH PER BUILDER

4"-6" MIN.
SOFFIT BLOCKING

HO
RIZ 8" M
. (R I ASPHALT SHINGLES BY
EXTERIOR SOFFIT BOARD OO N.
1/2" MIN.
1" MAX.

FS BUILDER INSTALLED PER


A DD
LE) MFG.
INSTRUCTIONS/SPECS

ROOF UNDERLAYMENT
OVER ICE & WATER
1/4" BACKER ROD AND
MEMBRANE
SEALANT
FRIEZE BAND

CAULK BETWEEN FRIEZE OPTIONAL


BAND AND SIDING SECONDARY BASE
FLASHING OVER
TRUSS, RE: STRUCTURAL ROOF
UNDERLAYMENT
WATER RESISTIVE BARRIER
PER BUILDING CODE

HORIZONTAL LAP SIDING PER


BUILDER
CONTINUOUS
EXTERIOR SHEATHING WATER RESISTIVE BARRIER
(ONE LAYER UNDER SIDING
APPLICATION)
SECTION VIEW
SECTION VIEW OVERLAPPING GALVANIZED
FLASHING

0613A
GABLE END DETAIL EXTERIOR WALL
LAP SIDING EXTERIOR
0602B
HEAD WALL FLASHING
SIDING SCALE: 3" = 1'-0" FINISH MATERIAL SIDING SCALE: 3" = 1'-0"
SHEATHING PER
STRUCTURAL
TO SEAL EXPOSED END
FACE OF BLOCKING, USE A
PRE-FORMED GALVANIZED
METAL FLASHING END CAP
W/ EXTENDED FLANGES
DASHED LINE
: WHEN SPECIAL CONDITIONS EXIST ROOF SHINGLES PER BUILDER REPRESENTS 7" WIDE
(STEPPING, NORTH FACING, ETC.) BUILDER TO CONTINUOUS GALVANIZED
FIELD VERIFY ICE & WATER SHIELD ROOF FASCIA PLACE GALVANIZED METAL BASE STEP
FLASHING W/ KICKOUT FLASHING STRIPS PER
2X SUB FASCIA SET DIRECTLY EDGE OVER BLOCKING AND MANUF. SPEC. W/ 2"
3
BELOW ROOF SHEATHING TO HOLD STEP FLASHING, THE WRB OVERLAP AS WOULD A
PROVIDE FURRING STRIPS, MIN. 8" DOWN MUST LAP OVER THE SHINGLE OVERLAP RIDGE AND HIP CAP SHINGLES PER
THICK, 1 12" WIDE, BETWEEN WEATHER
RESISTIVE BARRIER & HARDBOARD CONTINUOUS DRIP EDGE FLASHING, LAP FLASHING MANUF. SPEC.
PANEL SIDING. INSTALL PER OVER UNDERLAYMENT
LINE OF WATER RESISTIVE ROOFING MATERIAL
MANUFACTURER'S RECOMMENDATIONS. BARRER - IN WATER
ROOF UNDERLAYMENT EXTENDING OVER ADHERE ICE AND WATER MEMBRANE
SHEDDING LAPS, FLASHING TO WALL AND OVER RIDGE TOP SHEATHING AND ROOFING MATERIAL
INTEGRATE WRB W/ AT EDGE OF EAVE EXTEND DOWN ROOF SLOPE ON INSTALLED PER MANUF. SPECS.
GALVANIZED END CAP SHINGLES MUST BOTH SIDES FOR A MIN. OF 18" AND
AND FLANGES AT END OF OVERHANG DRIP EDGE LAPPING OVER ROOF
BLOCKING 1/4" TO 3/4", PER MFG. UNDERLAYMENT, FASTEN AS
INSTRUCTIONS/SPECS. NECESSARY
DASHED LINE OF TIGHT ROOF SHEATHING
OVERHANG FITTED BLOCKING PER STRUCT.

SOFFIT BLOCKING
7" WIDE GALVANIZED METAL ROOFING UNDERLAYMENT
DRIP EDGE FLASHING PER OVERLAPPING DRIP EDGE
MANUF. SPEC. AT EAVE, FLASHING AND ICE &
EXTERIOR SOFFIT BOARD OVERLAP ICE & WATER WATER SHIELD
1/2" MIN.
1" MAX.

SHIELD AND OVER FASCIA MEMBRANE


TRIM, EXTENDING 4" (MIN.)
ONTO ROOF SURFACE W/ 2"
OVERLAP BETWEEN ICE & WATER SHIELD
FLASHING PIECES. FLASHING DIRECTLY OVER ROOF
1/4" BACKER ROD AND WILL TERMINATE IN GUTTER SHEATHING, RE: MANUF.
SEALANT W/ A DRIP EDGE. SPEC.
EXTEND ICE & WATER
FRIEZE BAND .
SHIELD AND ROOF MIN FG.
UNDERLAYMENT UP WALL 18" W/ M
Y
HANGING GUTTER SHEATHING 6" BEHIND RIF INSTALL BLOCKING OR
HARDBOARD PANEL SIDING VE
WATER RESISTIVE CLIPS AT EDGES OF
PER BUILDER KICKOUT FLASHING OF
PLACE EACH STEP FLASHING PIECE ABOUT 1/4" ABOVE BARRIER (WRB OVERLAPS SHEATHING
SUFFICIENT LENGTH AND
THE BOTTOM EDGE OF THE SHINGLE THAT WILL ROOF UNDERLAYMENT
ANGLE TO DIRECT THE STEP FLASHING) OR
TRUSS, RE: STRUCTURAL OVERLAP IT- JUST ENOUGH SO THAT THE FLASHING
WATER RUNNING DOWN PIECE IS NOT VISIBLE WHEN THE OVERLAPPING EXTEND UP TO A POINT
: WHEN SPECIAL CONDITIONS EXIST
WATER RESISTIVE BARRIER ROOF AWAY FROM SHINGLE IS IN PLACE. ABOVE THE HIGHEST
(STEPPING, NORTH FACING, ETC.) BUILDER TO
PER BUILDING CODE SIDING. INSTALL ABOVE EXPECTED LEVEL OF
FIELD VERIFY ICE & WATER SHIELD
DRIP EDGE FLASHING SNOW & ICE
EXTERIOR SHEATHING
AND GUTTER
: WHEN SPECIAL CONDITIONS EXIST (STEPPING, NORTH FACING, ETC.) BUILDER
TO FIELD VERIFY ICE & WATER SHIELD
SECTION VIEW SECTION VIEW

GABLE END DETAIL ROOF TO WALL @ RAKE RIDGE W/O VENT


0613B 0611C 0603A
HARDBOARD SIDING SCALE: 3" = 1'-0" SIDING SCALE: NTS ASPHALT ROOFING SCALE: 3" = 1'-0"
©
: WHEN SPECIAL CONDITIONS EXIST
(STEPPING, NORTH FACING, ETC.) BUILDER
TO FIELD VERIFY ICE & WATER SHIELD Godden|Sudik
A R C H I T E C T S
SEE WHAT COULD BE
ROOF SHINGLES PER
BUILDER
OVERHANG
ROOF FASCIAS

2X SUB FASCIA SET DIRECTLY STRUCTURAL HEADER,


BELOW ROOF SHEATHING TO AS REQUIRED; RE:
HOLD DOWN STRUCTURAL

DRIP EDGE FLASHING, LAP


AIR IMPERMEABLE INSULATION
SOFFIT BOARD OVER UNDERLAYMENT
APPLIED IN DIRECT CONTACT
PER BUILDER ROOF SHINGLES PER
WITH UNDERSIDE OF SHEATHING
ROOF UNDERLAYMENT BUILDER
PER BUILDING CODE

SOFFIT BLOCKING ROOF UNDERLAYMENT

OVERHANG, RE: ROOF PLANS


ICE BARRIER UNDERLAYMENT
HARDBOARD PANEL INSTALLED ALONG EAVES AND
BEYOND BRACKET WHERE ADDITIONALLY NOTED.
LAP OVER METAL FLASHING @
EAVES & EXTEND UP ROOF TO
ATTACH BRACKET 12 A POINT 24" MIN. INSIDE
WITH BOLT RE: ROOF EXTERIOR WALL LINE PER ROOF UNDERLAYMENT
PLAN CODE REQ'MENTS, TYP.
BLOCKING AS
REQUIRED . .
G
FOR BRACKET IN MF
" M /
CONTINUOUS FLASHING, LAP 18 Y W
I F
OVER GUTTER OR PROVIDE R
INTEGRATED GUTTER DRIP VE
EDGE SYSTEM
ROOFING MATERIAL INSTALLED
PER MFG. SPECS.

HEEL HEIGHT, RE: ELEVATIONS


ROOF GUTTER PER
BUILDER

INSTALL BLOCKING OR
CLIPS @ EDGES OF

1/2" CLEARANCE
SHEATHING

BELOW ROOF
SLOPE LINE
: WHEN SPECIAL CONDITIONS

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


EXIST (STEPPING, NORTH FACING, ROOF SHEATHING
ETC.) BUILDER TO FIELD VERIFY ICE & PER STRUCT.
WATER SHIELD
BRACKET
ADHERE ICE AND WATER
2x4 BACK BOARD MEMBRANE OVER THE
FASCIA TRIM, RE: TRANSITION POINT ON THE
PROVIDE FLEX ROOF SHEATHING AND ONTO

PHONE: 303-770-8300
ELEVATIONS
MEMBRANE AT ROOF SLOPE ON BOTH SIDES
BRACKET LOCATIONS, PLATE HEIGHT
FOR A MIN. OF 18" AND
PER BUILDER RE: ELEVATIONS
LAPPING OVER ROOF

1/2" MIN.
1" MAX.
UNDERLAYMENT, FASTEN AS
BLOCKING AS NECESSARY
REQUIRED 2X SUB-FASCIA SET
FOR BRACKET FILL REMAINING CAVITY WITH DIRECTLY BELOW ROOF
BATT OR BLOWN INSULATION, TYP. SHEATHING TO HOLD
ATTACH BRACKET SOFFIT BOARD PER BUILDER DOWN : WHEN SPECIAL CONDITIONS EXIST
WITH BOLT ATTACH BOTH ENDS AT SOLID (STEPPING, NORTH FACING, ETC.) BUILDER TO
BLOCKING, TYP. FIELD VERIFY ICE & WATER SHIELD
BACKER ROD AND SEALANT
WATER RESISTIVE BARRIER
- PER BUILDING CODE
FRIEZE BAND
CAULK BETWEEN FRIEZE BAND AND EXTERIOR MATERIAL SECTION VIEW
EXTERIOR MATERIAL, RE: BUILDING ELEVATIONS
SECTION VIEW SECTION VIEW WATER RESISTIVE BARRIER,
PER BUILDING CODE

0615
BRACKET DETAIL 0623A
UNVENTED ENCLOSED RAFTER 0606
ROOF PITCH CHANGE
SIDING SCALE: 3" = 1'-0" ROOF SCALE: 3" = 1'-0"
SCALE: 3" = 1'-0"

ROOF SHINGLES PER


: WHEN SPECIAL CONDITIONS EXIST BUILDER
(STEPPING, NORTH FACING, ETC.) BUILDER
TO FIELD VERIFY ICE & WATER SHIELD
ROOF UNDERLAYMENT
12 ROOF GUTTER PER
STRUCTURAL HEADER, BUILDER
AS REQUIRED; RE: RE: ROOF
STRUCTURAL PLAN
RAFTER
CONTINUOUS FLASHING
AIR IMPERMEABLE INSULATION
APPLIED IN DIRECT CONTACT
WITH UNDERSIDE OF SHEATHING
CL ICE BARRIER
UNDERLAYMENT LAP OVER
PER BUILDING CODE
CONTINUOUS FLASHING AT
EAVES AS SHOWN
ROOF SHINGLES PER BUILDER
OVERHANG, RE: ROOF PLANS ROOF UNDERLAYMENT 2X SUB FASCIA SET
DIRECTLY BELOW
ROOF SHEATHING TO
ICE BARRIER UNDERLAYMENT HOLD DOWN
INSTALLED ALONG EAVES AND
12 WHERE ADDITIONALLY NOTED.
RE: ROOF LAP OVER METAL FLASHING @
PLAN EAVES & EXTEND UP ROOF TO A
POINT 24" MIN. INSIDE EXTERIOR
WALL LINE PER CODE
REQ'MENTS, TYP.
CONTINUOUS FLASHING, LAP
OVER GUTTER OR PROVIDE
INTEGRATED GUTTER DRIP
EDGE SYSTEM

HEEL HEIGHT, RE: ELEVATIONS


ROOF GUTTER PER RE:ROOF
BUILDER WRB UNDER RAFTER PLAN

SOFFIT BOARD

1/2" CLEARANCE
CAULK BETWEEN

BELOW ROOF
SLOPE LINE
BEAM WRAP & SOFFIT
BOARD

BEAM

BEAM WRAP
FASCIA TRIM
FASCIA TRIM
PLATE HEIGHT
RE: ELEVATIONS
CAULK BETWEEN
BEAM WRAP VENTED SOFFIT
2X SUB-FASCIA SET
1/2" MIN.
1" MAX.

FILL REMAINING CAVITY WITH DIRECTLY BELOW ROOF


BATT OR BLOWN INSULATION, TYP. SHEATHING TO HOLD COLUMN W/
DOWN HARDBOARD WRAP
2 LAYERS OF 58" TYPE X WATER RESISTIVE BARRIER
SOFFIT BOARD PER BUILDER, GYP. BD. PER FIRE RATED
ATTACH BOTH ENDS AT SOLID ASSEMBLY
BLOCKING, TYP. WATER RESISTIVE
BARRIER BETWEEN
BACKER ROD AND SEALANT
COLUMN & WRAP FURRING AS REQ'D. TO
ALIGN W/ FACE OF COLUMN
FRIEZE BAND
CAULK BETWEEN FRIEZE BAND AND EXTERIOR MATERIAL
: WHEN SPECIAL
EXTERIOR MATERIAL, RE: BUILDING ELEVATIONS CONDITIONS EXIST
WATER RESISTIVE BARRIER, (STEPPING, NORTH FACING,
PER BUILDING CODE ETC.) BUILDER TO FIELD

SECTION VIEW 5
8"TYPE X GYP. PER FIRE
VERIFY ICE & WATER SHIELD SECTION VIEW
RATED ASSEMBLY

0623A
UNVENTED ENCLOSED RAFTER 0620
ROOF AT PORCH COLUMN
RATED ROOF SCALE: 3" = 1'-0" ASPHALT ROOFING SCALE: 3" = 1'-0"
©
SELF-ADHERING MODIFIED BITUMEN NOTE : WHEN SPECIAL CONDITIONS EXIST (STEPPING, NORTH
GALVANIZED SHEET METAL RIDGE ROOF TAPE WITH MINIMUM 1" FACING, ETC.) BUILDER TO FIELD VERIFY ICE & WATER
FLASHING OVERLAP SHIELD
GALVANIZED STEP FLASHING WITH FOR THE FIRST 36" FROM LOWEST EDGE OF ROOF, ADD MIN.
ICE AND WATER MEMBRANE OVER
ROOF UNDERLAYMENT, FASTEN AS
MINIMUM 3" OVERLAP 36" WIDE, SELF-ADHERING ICE & WATER MEMBRANE UNDER Godden|Sudik
ROOFING UNDERLAYMENT. INSTALL PER MANUF. SPECS.
NECESSARY A R C H I T E C T S
EDGE OF METAL VALLEY FLASHING SHALL BE A FORMED
SEE WHAT COULD BE
MIN HOOK EDGE (ALSO CREATING A DAM STOPPING MOISTURE
IMU FROM FLOWING OUT OF VALLEY) W/ CLEATS @ 24" O.C.
M3
"O

P
VE MAX. CLEATS SHOULD ALLOW MOVEMENT FOR THERMAL

RLA
RLA EXPANSION. NO NAILS SHALL PENETRATE METAL FLASHING.
P

VE
ROOF SHEATHING PER STRUCT. USE H-CLIPS, SOLID

"O
BLOCKING, OR TONGUE-AND-GROOVE AT EDGES.

M1
IMU
CL RECOMMENDED: GALVANIZED STEEL, MINIMUM 0.018"
METAL VALLEY FLASHING, MAXIMUM 10' LONG OVER ICE &

MIN
MIN WATER MEMBRANE. 18" MIN. WIDTH FOR SLOPES 6IN./FT
OR MORE (FLASHINGS BELOW THIS SLOPE SHOULD BE 24"
I MU
WIDE)
MINIMUM 12" OVERLAP BETWEEN METAL SECTIONS.
M4
"

EXTEND SHINGLES MIN. 12" PAST VALLEY CENTERLINE, PRESS


SHINGLES TIGHT INTO VALLEY AND NAIL IN PLACE. NO
FASTENERS WITHIN 6" OF CENTERLINE OF VALLEY. ADD
EXTRA NAIL AT EACH END SHINGLE THAT CROSSES VALLEY.
EXTERIOR SHEATHING ROOF UNDERLAYMENT
SNAP CHALK LINE 2" OUT FROM THE VALLEY CENTERLINE ON WOVEN OVER VALLEY
ROOF SHEATHING THE OPPOSITE SLOPE AND SHINGLE UP THE OTHER SIDE OF
PER STRUCT. THE VALLEY, HOLD NAILS BACK 6" FROM THE VALLEY WATER RESISTIVE BARRIER, LAP
CENTER. TRIM EACH SHINGLE TO THE GUIDE LINE OVER COUNTERFLASHING
.
MIN FG.
18" W/ M CLIP OFF 1" OF THE UPHILL CORNER OF EACH SHINGLE AT 45 ASPHALT SHINGLES BY BUILDER
Y
RIF INSTALL BLOCKING OR DEGREE ANGLE. NO NAILS INSIDE METAL FLASHING - SEAL
VE SHINGLE TO VALLEY AND TO OVERLAPPING SHINGLE WITH 3"
HORIZONTAL LAP SIDING PER
CLIPS AT EDGES OF BUILDER
SHEATHING WIDE BEAD OF ASPHALT PLASTIC CEMENT.
ICE AND WATER STARTER STRIP ICE AND WATER SHIELD MEMBRANE
MEMBRANE ROOF ROOFING MATERIAL INSTALLED PER MANUF. SPECS (VALLEY
UNDERLAYMENT SIDE W/ LOWER SLOPE OR LESSER HEIGHT GETS SHINGLED
: WHEN SPECIAL CONDITIONS EXIST (STEPPING, NORTH FIRST) GALVANIZED DRIP CAP FLASHING
FACING, ETC.) BUILDER TO FIELD VERIFY ICE & WATER ROOFING UNDERLAYMENT INSTALLED PER MANUF. SPEC. AND
SHIELD GALVANIZED FLASHING

SECTION VIEW AXON VIEW EXTENDING MIN. 6" OVER THE METAL VALLEY FLASHING.
STEP FLASHING
EXTEND VALLEY FLASHING AT LEAST 2" OUT FROM CORNER 1X NAILER 36" WIDE VALLEY FELT
OF TRIM
2X FIRE BLOCKING CLOSED VALLEY

RIDGE TO WALL FLASHING CLOSED VALLEY

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


0621 0608B
HARDBOARD SIDING SCALE: 3" = 1'-0" SIDING SCALE: NTS

PHONE: 303-770-8300
WHEN SPECIAL CONDITIONS EXIST CONTINUOUS LEDGER
(STEPPING, NORTH FACING, ETC.) BUILDER TO
FIELD VERIFY ICE & WATER SHIELD

FROM LOWEST EDGE OF ROOF TO FULL LENGTH


OF VALLEY, ADD MIN. 36" WIDE, SELF-ADHERING
ICE & WATER MEMBRANE UNDER ROOFING
UNDERLAYMENT. INSTALL PER MANUF. SPECS.

ROOF SHEATHING PER STRUCT. USE H-CLIPS, SOLID


BLOCKING, OR TONGUE-AND-GROOVE AT EDGES.
ROOF SHEATHING
MIN. 0.018" GALVANIZED STEEL VALLEY FLASHING,
MIN. 24" WIDE & MAX 10' LONG. WHERE THE SLOPES
VARY OR ARE LESS THAN 6:12, ADD A 1" H.
V-CRIMP @ CENTER.

ROOF SHEATHING PER STRUCT.


MINIMUM 12" OVERLAP BETWEEN METAL SECTIONS.

EDGE OF VALLEY FLASHING SHALL BE A FORMED


HOOK EDGE (ALSO CREATING A DAM STOPPING
MOISTURE FROM FLOWING OUT OF VALLEY) W/ TRUSS RE: STRUCTURAL
CLEATS @ 24" O.C. MAX. CLEATS SHOULD ALLOW
MOVEMENT FOR THERMAL EXPANSION. NO NAILS
SHALL PENETRATE METAL FLASHING.
ROOFING UNDERLAYMENT INSTALLED PER
MANUF. SPEC. AND EXTENDING MIN. 6" OVER
THE METAL VALLEY FLASHING.

ROOFING MATERIAL INSTALLED PER MANUF.


SPECS W/ 1" CLIPPED OFF CORNER AT 45
DEGREE ANGLE. NO NAILS INSIDE METAL
SECTION VIEW
FLASHING - SEAL WITH ASPHALT PLASTIC
CEMENT.

OPEN VALLEY WIDTH: 6" AT TOP INCREASING


BY 1/8" PER FOOT OF VALLEY RUN. SHINGLE
TO CHALKLINES

AXON VIEW EXTEND VALLEY FLASHING AT LEAST 2" OUT


FROM CORNER OF TRIM

0607
OPEN VALLEY 0622
ROOF CRICKET DETAIL
SIDING SCALE: NTS SIDING SCALE: 3" = 1'-0"

EXTERIOR SHEATHING
LATH W/ SCRATCH COAT
ADHERED MASONRY VENEER
EXTERIOR SHEATHING PER BUILDER

WATER-RESISTIVE BARRIER - PER MORTAR SETTING BED


BUILDING CODE WATER-RESISTIVE BARRIER WITH A
PERFORMANCE AT LEAST EQUIVALENT TO 2
LAYERS OF GRADE D PAPER - PER BUILDING
HORIZONTAL LAP SIDING CODE - LAP WRB OVER WEEP SCREED

STARTER STRIP WEEP SCREED

1/4" GAP MIN.


1/2" GAP MIN.
BETWEEN FLASHING AND SIDING
BETWEEN MASONRY AND FLASHING

GALVANIZED FLASHING TURN UP


GALVANIZED FLASHING
WALL MIN. 2" AND LAP W/ WRB
SOLID BLOCKING
SOLID BLOCKING

FLEXIBLE FLASHING, LAP BETWEEN


WATER RESISTIVE BARRIER AND BACKER
BOARD
FLEXIBLE FLASHING, LAP BETWEEN
WATER RESISTIVE BARRIER AND TRIM
GUARDRAIL PER BUILDER - RE:
STRUCTURAL PLANS FOR
GUARDRAIL PER BUILDER - RE: CONNECTION
STRUCTURAL PLANS FOR
TRIM OVER BACKER BOARD - SET FLUSH W/
CONNECTION
FINISHED FACE OF MASONRY
TRIM
GALVANIZED FLASHING
1/8" GAP W/ SEALANT
CASING BEAD

SECTION VIEW SECTION VIEW

0128
RAILING ATTACHMENT 0416
RAILING ATTACHMENT
SIDING SCALE: 3" = 1'-0" ADHERED MASONRY VENEER SCALE: 3" = 1'-0"
©
GUARDRAIL PER BUILDER - RE:
STRUCTURAL PLANS FOR
CONNECTION Godden|Sudik
A R C H I T E C T S
DECKING MATERIAL PER BUILDER SEE WHAT COULD BE
WATER RESISTIVE VAPOR PERMEABLE
BARRIER WITH A PERFORMANCE AT
LEAST EQUIVALENT TO 2 LAYERS OF
ROOFING SHINGLES
GRADE D PAPER BEHIND ADHERED
OVER GALVANIZED MIN. 6" OVERLAP OF

MIN.
MASONRY
FLANGE ROOFING
UNDERLAYMENT OVER

6"
TOP EDGE OF BASE
FLANGE

EXTEND DECKING MATERIAL OVER


OUTSIDE FACE OF DECK FASCIA ADHERED MASONRY VENEER ADHERED MASONRY PER PLACE GALVANIZED FLASHING AND
PER BUILDER, TERMINATE IN BUILDER FLANGE OVER VENT PIPE AND
WEEP SCREED AT VENT SECURE WITH GALVANIZED
PRESSURE TREATED DECK COLLAR SCREWS OR SET IN ASPHALT
JOISTS AND LEDGER - RE: PLASTIC CEMENT
STRUCTURAL PLANS FOR EXTERIOR SHEATHING CONTINUOUS BEAD OF NOTE: INSTALL VENT FLASHING
ATTACHMENT REQUIREMENTS SEALANT BETWEEN TOP OF OVER ROOFING UNDERLAYMENT
WATER RESISTIVE VAPOR BOX AND WEEP SCREED (THE ASPHALT ROOFING TILE WILL
1" MIN. BE CUT TO FIT OVER THE PIPE
PERMEABLE BARRIER WITH A
PERFORMANCE AT LEAST BEFORE THE VENT FLASHING IS
EQUIVALENT TO 2 LAYERS OF GRADE INSTALLED
PROVIDE HOT DIPPED D PAPER, LAP OVER FLASHING TAPE
DECK FASCIA AND VENT COLLAR APPLY SELF-ADHERING,
GALVANIZED OR STAINLESS
SELF-SEALING FLASHING OVER
STEEL STRUCTURAL HANGER / PLACE THE SCREWS TO
EXTERIOR SHEATHING BEHIND ELEC.
HARDWARE -

VERIFY W/
2X FRAME BOX AND EXTENDING A MIN. OF 6" THE OUTSIDE SO THEY

EQUIP.
WALL PAST THE SIDES OF THE BOX AND WILL BE COVERED WITH
FLEXIBLE FLASHING TAPE THE ROOFING SHINGLES
EXTEND UP VERTICALLY BEHIND
LAP DRYER VENT
WRB. FLASHING CANNOT BE LEFT
COLLAR
PERMANENTLY EXPOSED ROOFING SHINGLES
CONTINUOUS SEALANT UNDER GALVANIZED
AROUND PERIMETER FLANGE

HATCHED AREA
INDICATES ROOFING
PREMANUFACTURED DRYER
SECTION VIEW VENT WITH FLASHING
UNDERLAYMENT

COLLAR/WEEP SCREED ROOFING SHINGLES

UPPER AND SIDE


END OF DRAIN-THROUGH DECK

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SHINGLES OVERLAP
THE ELECTRICAL BOX WILL BE
FLANGE, SET IN ASPHALT
1009B INSTALLED DIRECTLY OVER THE
PLASTIC CEMENT
@ END OF DECK SCALE: 3" = 1'-0" SELF-ADHERING FLASHING,
DRYER VENT CAP
CONTINUE THE WRB BELOW THE
INSTALL DRYER VENT BOX UNDER THE FLASHING LOWER PART OF FLANGE
COLLAR IN CONTINUOUS OVERLAPS LOWER
SEALANT OVER EXTERIOR SHINGLES
SHEATHING

PHONE: 303-770-8300
FLEXIBLE FLASHING
TAPE DRYER
VENT COLLAR
APPLY A BEAD OF
CEMENT AROUND THE
WRB LAPPING UNDER TOP OF THE FLASHING
FLASHING TAPE AND : WHEN SPECIAL CONDITIONS EXIST WHERE IT MEETS THE
DRYER VENT COLLAR (STEPPING, NORTH FACING, ETC.) BUILDER TO VENT PIPE
COLUMN FIELD VERIFY ICE & WATER SHIELD
FRAME IN AND FILL VOID
AROUND PENETRATION W/
MINIMALLY EXPANDING
SEAL BETWEEN COLUMN POLYURETHANE FOAM OR
AND TRIM APPROVED SEALANT
SECTION VIEW
TRIM TO COVER COLUMN SECTION VIEW
CONNECTION

0906
DRYER VENT DETAIL 0905
ELECTRICAL BOX DETAIL 0902
ROOF VENT DETAIL
2" MIN.

SIMPSON COLUMN BASE ADHERED MASONRY VENEER SCALE: 3" = 1'-0" ADHERED MASONRY VENEER SCALE: 3" = 1'-0" ASPHALT ROOFING SCALE: 3" = 1'-0"
HARDWARE, RE: STRUCTURAL

SLAB, RE: STRUCTURAL

WATER RESISTIVE BARRIER

SECTION VIEW
HORIZONTAL LAP

1/4" GAP
DO NOT
SIDING

CAULK
EXTERIOR SHEATHING SIDING PER BUILDER

1011A
RAISED COLUMN BASE DETAIL WRB LAYER
APPLIED OVER WATER
RESISTIVE BARRIER BACKFILL AROUND DRAIN
SHOULD BE WITH
CONCRETE SLAB SCALE: 3" = 1'-0" COMPACTED ON-SITE SOILS
STOP SHORT THE LAP SIDING
1/4" ABOVE THE FLASHING, DO COVER WITH DRAIN CAP.
NOT CAULK THE 1/4" GAP SET DRAIN CAP FLUSH W/
APPLY SELF-ADHERING,
ROCK.
SELF-SEALING FLASHING
INSTALL GALVANIZED
OVER EXTERIOR 4" DIA. PVC PERFORATED
FLASHING WITH DRIP EDGE

VERIFY W/
SHEATHING BEHIND ELEC. PIPE WRAPPED WITH
KICKOUT OVER THE TOP OF

EQUIP.
BOX AND EXTENDING A MIN. GEOTEXTILE FABRIC
THE TRIM BLOCK
OF 6" PAST THE SIDES OF
THE BOX AND EXTEND UP 12" MIN. GRAVEL BED
VERTICALLY BEHIND WRB.
FLASHING CANNOT BE LEFT 4" DIA. SOLID PIPE UNDER
WEATHER-CUT TRIM BLOCK PERMANENTLY EXPOSED FOOTING @ MIN. SLOPE OF
INTO 2 PIECES TO FIT AROUND 1/8" PER FOOT CONNECTED
THE VENT PENETRATION TO EXISTING FOUNDATION
NOTE: MIN. 22.5° WEATHER DRAIN SYSTEM
CUT
GRAVEL BED UNDER

6" MIN.
FOOTING AND AROUND PIPE
CAULK BETWEEN
ELECTRICAL BOX AND
SIDING THE ELECTRICAL
BOX WILL BE
INSTALLED DIRECTLY
OVER THE
SELF-ADHERING
FLASHING,
CONTINUE THE WRB
BELOW THE BOX
UNDER THE
FLASHING

CAULK BETWEEN
TRIM BOARD
AND SIDING

PRE-MFG.
DRYER VENT
ENCASE PIPE IN
1/2" TO 3/4"
WASHED GRAVEL.
EXTEND GRAVEL
TO MIN. 1/2 OF THE
HEIGHT OF THE
FOOTING
4" DIA. AND FILL
SECTION VIEW SECTION VIEW TRENCH WITH
PERFORATED
GRAVEL
DRAIN PIPE @ MIN.
1/8" PER FOOT
SLOPE TO DRAIN

0907
SIDEWALL VENT DETAIL 0909
ELECTRICAL BOX DETAIL 0000
WINDOW WELL DRAIN
SIDING SCALE: NTS SIDING SCALE: 3" = 1'-0" SCALE: NTS
©
PROVIDE FURRING STRIPS, MIN. 3 8" INSULATION SUFFICIENT TO FILL
THICK, 1 12" WIDE, BETWEEN
WATER-RESISTIVE BARRIER &
WALL CAVITY
EXTERIOR SHEATHING GYP BOARD WITH CONTINUOUS SEALANT
INSULATION SUFFICIENT TO FILL
WALL CAVITY
Godden|Sudik
PROVIDE FURRING STRIPS, MIN. 3 8"
THICK, 1 12" WIDE, BETWEEN
HARDBOARD PANEL SIDING.
HARDBOARD PANEL SIDING PER
AT BOTTOM OF FRAMED WALL HORIZONTAL LAP SIDING A R C H I T E C T S
WATER-RESISTIVE BARRIER & INSULATION SUFFICIENT TO FILL INSTALL PER MANUFACTURER'S
BUILDER SEE WHAT COULD BE
HARDBOARD PANEL SIDING. WALL CAVITY RECOMMENDATIONS. EXTERIOR SHEATHING
INSTALL PER MANUFACTURER'S EXTERIOR SHEATHING GYP BOARD WITH CONTINUOUS SEALANT WATER-RESISTIVE BARRIER APPLIED
FINISH FLOOR WATER RESISTIVE BARRIER
RECOMMENDATIONS. AT BOTTOM OF FRAMED WALL PRIOR TO DECK INSULATION
HARDBOARD PANEL SIDING PER APPLIED PRIOR TO DECK
GYP BOARD WITH CONTINUOUS SEALANT BUILDER FINISH FLOOR INSTALLATION
AT BOTTOM OF FRAMED WALL FLEXIBLE FLASHING APPLIED
OVER THE GALVANIZED STARTER STRIP
FINISH FLOOR FLASHING
WATER-RESISTIVE BARRIER APPLIED
1/4" GAP MIN.
PRIOR TO DECK INSULATION
1/4" GAP MIN. BETWEEN FLASHING AND SIDING
FLEXIBLE FLASHING APPLIED BETWEEN FLASHING AND TRIM
OVER THE GALVANIZED GALVANIZED FLASHING
FLASHING FLOOR SHEATHING GALVANIZED FLASHING FLOOR SHEATHING
1/4" GAP MIN.
BETWEEN FLASHING AND TRIM DECKING MATERIAL PER DECKING MATERIAL PER
FLOOR SHEATHING BUILDER (4" MIN. STEP FROM BUILDER (4" MIN. STEP FROM

2" MIN.

2" MIN.
GALVANIZED FLASHING
FINISH FLOOR) FINISH FLOOR)
DECKING MATERIAL PER

2" MIN.
BUILDER (4" MIN. STEP FROM GALVANIZED FLASHING GALVANIZED FLASHING
FINISH FLOOR) WOOD FLOOR JOIST WOOD FLOOR JOIST
GALVANIZED FLASHING
WOOD FLOOR JOIST
RIM JOIST RIM JOIST

RIM JOIST PRESSURE TREATED DECK JOISTS PRESSURE TREATED DECK JOISTS
AND LEDGER - RE: STRUCTURAL AND LEDGER - RE: STRUCTURAL
PLANS FOR ATTACHMENT PLANS FOR ATTACHMENT
PRESSURE TREATED DECK JOISTS INSULATION SUFFICIENT INSULATION SUFFICIENT TO FILL
REQUIREMENTS REQUIREMENTS
AND LEDGER - RE: STRUCTURAL TO FILL RIM JOIST CAVITY RIM JOIST CAVITY
PLANS FOR ATTACHMENT
INSULATION SUFFICIENT TO FILL REQUIREMENTS
RIM JOIST CAVITY

PROVIDE HOT DIPPED GALVANIZED PROVIDE HOT DIPPED GALVANIZED


OR STAINLESS STEEL OR STAINLESS STEEL
STRUCTURAL HANGER / STRUCTURAL HANGER /
PROVIDE HOT DIPPED GALVANIZED
HARDWARE - HARDWARE -
OR STAINLESS STEEL
STRUCTURAL HANGER /
HARDWARE - DOUBLE TOP PLATE DOUBLE TOP PLATE

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


DOUBLE TOP PLATE

GALVANIZED FLASHING GALVANIZED FLASHING


GYP BOARD WITH CONTINUOUS SEALANT GYP BOARD WITH CONTINUOUS SEALANT
AT TOP OF FRAMED WALL AT TOP OF FRAMED WALL
GALVANIZED FLASHING
GYP BOARD WITH CONTINUOUS SEALANT

PHONE: 303-770-8300
AT TOP OF FRAMED WALL FLEXIBLE MEMBRANE FLASHING, FLEXIBLE MEMBRANE FLASHING,
INSULATION SUFFICIENT TO FILL INSULATION SUFFICIENT TO FILL
WALL CAVITY SET BEHIND GALVANIZED FLASHING WALL CAVITY SET BEHIND GALVANIZED FLASHING

INSULATION SUFFICIENT TO FILL FLEXIBLE MEMBRANE FLASHING,


WALL CAVITY SET BEHIND GALVANIZED FLASHING

TRIM TRIM
EXTERIOR SHEATHING TRIM
1/8" GAP W/ SEALANT 1/8" GAP W/ SEALANT
1/8" GAP W/ SEALANT EXTERIOR SHEATHING EXTERIOR SHEATHING
HORIZONTAL LAP SIDING HORIZONTAL LAP SIDING
HORIZONTAL LAP SIDING

WATER RESISTIVE BARRIER - PER


BUILDING CODE WATER RESISTIVE BARRIER - PER WATER RESISTIVE BARRIER - PER
BUILDING CODE BUILDING CODE

SECTION VIEW SECTION VIEW SECTION VIEW

BASE OF WALL @ DECK BASE OF WALL @ DECK BASE OF WALL @ DECK


0123A 0123A 0123A
HARDBOARD SIDING SCALE: 3" = 1'-0" SIDING & HARDBOARD SIDING SCALE: 3" = 1'-0" SIDING SCALE: 3" = 1'-0"

PROVIDE FURRING STRIPS, MIN. 3 8"


THICK, 1 12" WIDE, BETWEEN
WATER-RESISTIVE BARRIER & SLIDING GLASS DOOR PER
SECTION VIEW SECTION VIEW
HARDBOARD PANEL SIDING. BUILDER
INSTALL PER MANUFACTURER'S SILL PAN FLASH WITH REAR & SIDE
RECOMMENDATIONS. EDGES TURNED UP. ALL CORNERS SILL PAN FLASH WITH REAR & SIDE
SLIDING GLASS DOOR PER
GALVANIZED SILL PAN FLASH SHALL BE SEALED AND WATERTIGHT. EDGES TURNED UP. ALL CORNERS
BUILDER
BEYOND LAP OVER FLASHING TO ALLOW SHALL BE SEALED AND WATERTIGHT.
DRAINAGE GALVANIZED SILL PAN FLASH LAP OVER FLASHING TO ALLOW
CONTINUOUS SEALANT BEYOND DRAINAGE
BACKER ROD AND SEALANT
CONTINUOUS SEALANT BACKER ROD AND SEALANT
FINISH FLOOR TRIM BOARD - INSTALL OVER SPACERS TRIM BOARD - INSTALL OVER SPACERS
OR DRAINAGE MAT BEHIND TO PROVIDE FINISH FLOOR OR DRAINAGE MAT BEHIND TO PROVIDE
DRAINAGE/AIR SPACE DRAINAGE/AIR SPACE

WATER-RESISTIVE BARRIER WATER-RESISTIVE BARRIER


APPLIED PRIOR TO DOOR APPLIED PRIOR TO DOOR
INSTALLATION, LAPPED BY SILL INSTALLATION, LAPPED BY SILL
AND PAN FLASHING AND PAN FLASHING
FLOOR SHEATHING FLOOR SHEATHING
DECKING MATERIAL PER BUILDER (4" DECKING MATERIAL PER BUILDER (4"
MIN. STEP FROM FINISH FLOOR) MIN. STEP FROM FINISH FLOOR)

2" MIN.

2" MIN.
GALVANIZED FLASHING GALVANIZED FLASHING

WOOD FLOOR JOIST WOOD FLOOR JOIST

RIM JOIST RIM JOIST

PRESSURE TREATED DECK JOISTS PRESSURE TREATED DECK JOISTS


AND LEDGER - RE: STRUCTURAL AND LEDGER - RE: STRUCTURAL
PLANS FOR ATTACHMENT PLANS FOR ATTACHMENT
INSULATION SUFFICIENT TO FILL REQUIREMENTS INSULATION SUFFICIENT REQUIREMENTS
RIM JOIST CAVITY TO FILL RIM JOIST CAVITY

PROVIDE HOT DIPPED GALVANIZED PROVIDE HOT DIPPED GALVANIZED


OR STAINLESS STEEL OR STAINLESS STEEL
STRUCTURAL HANGER / STRUCTURAL HANGER /
HARDWARE - HARDWARE -

PRESSURE TREATED PRESSURE TREATED


SILL PLATE SILL PLATE

GYP BD WITH CONTINUOUS SEALANT AT GYP BD WITH CONTINUOUS SEALANT AT


TOP OF FRAMED WALL TOP OF FRAMED WALL
GALVANIZED FLASHING GALVANIZED FLASHING

FLEXIBLE MEMBRANE FLASHING, MEMBRANE


SET INTO ROUGH OPENING, BENEATH SILL
PAN AND TURNED DOWN TO COVER FLEXIBLE MEMBRANE FLASHING, MEMBRANE
INSULATION SUFFICIENT TO FILL SHEATHING INSULATION SUFFICIENT TO FILL SET INTO ROUGH OPENING, BENEATH SILL
WALL CAVITY WALL CAVITY PAN AND TURNED DOWN TO COVER
TRIM SHEATHING
1/4" REVEAL BETWEEN
TRIM AND PANEL
TRIM
GALVANIZED FLASHING
EXTERIOR SHEATHING EXTERIOR SHEATHING 1/8" GAP W/ SEALANT

HARDBOARD PANEL SIDING HORIZONTAL LAP SIDING


PER BUILDER
WATER-RESISTIVE BARRIER - PER
BUILDING CODE WATER-RESISTIVE BARRIER - PER
BUILDING CODE

SLIDING GLASS DOOR @ SLIDING GLASS DOOR @


0121C
THROUGH-DRAIN DECK 0121C
THROUGH-DRAIN DECK
HARDBOARD SIDING SCALE: 3" = 1'-0" SIDING SCALE: 3" = 1'-0"
©
Godden|Sudik
A R C H I T E C T S
SEE WHAT COULD BE

PRE-CUT STRINGER BEYOND

STAIR TREAD

FALSE STRINGER

GYPSUM BOARD

2X FRAMING

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


PHONE: 303-770-8300
CUT STRINGER DETAIL
2 SCALE: 1/4" = 1'-0"

TERMINATE CURB WALL @


TOP OF LANDING W/ CAP
ATOP FINISHED FLOOR

NEWEL POST

PRE-CUT STRINGER BEYOND

STAIR TREAD

PRE-CUT STRINGER

CURB WALL W/ CAP

OPEN RAIL
SECTION VIEW PLAN VIEW

OPEN RAIL

CURB WALL W/ CAP

STAIR TREAD

PRE-CUT
STRINGER BEYOND

OPEN RAIL @ LANDING DETAIL CUT STRINGER @ CURB WALL


3 SCALE: 1/4" = 1'-0" 1 SCALE: NTS

©
THERMAL BARRIER NOTES
CLASS I, II OR III VAPOR RETARDERS ARE REQUIRED ON THE
SECTION VIEW SECTION VIEW SECTION VIEW INTERIOR SIDE OF FRAME WALLS IN CLIMATE ZONE 5 PER
R702.7.
THE FOLLOWING SHALL BE DEEMED TO MEET THE CLASS
2X BLOCKING, FIELD EXTERIOR WALL EXTERIOR WALL EXTERIOR WALL SPECIFIED :
VERIFY SHEATHING SHEATHING SHEATHING CLASS I: SHEET POLYETHYLENE, ON PERFORATED ALUMINUM

TUB OR SHOWER EXTERIOR WALL EXTERIOR WALL EXTERIOR WALL


FOIL PER R702.7.2.
CLASS II: KRAFT-FACED FIBERGLASS BATTS PER R702.7.2. Godden|Sudik
PAN CLASS III: LATEX OR ENAMEL PAINT, RE: R702.7.1 AND R702.7.2.
INSULATION INSULATION INSULATION A R C H I T E C T S
AIR BARRIER - SEAL GYPSUM BOARD GYPSUM BOARD GYPSUM BOARD THE BUILDING THERMAL ENVELOPE SHALL BE DURABLY SEE WHAT COULD BE
@ SEAMS & SEALED TO LIMIT INFILTRATION. THE SEALING METHODS
PERIMETER EDGES FLOOR SHEATHING INSULATION AIR BARRIER - CONTINUOUS BETWEEN DISSIMILAR MATERIALS SHALL ALLOW FOR
SILL PLATE SEALED ROOF SYSTEM RE:
@ INSIDE OF WALL ON FLOOR SYSTEM BAFFLE EXTERIOR WALL SHEATHING DIFFERENTIAL EXPANSION AND CONTRACTION. RE: N1102.4.
TO SUB-FLOOR STRUCT.
BEHIND TUB RE: STRUCT. BEHIND ROOF SYSTEM - SEAL
WHERE NECESSARY, OR AS DIRECTED BY CONTRACTOR,
@ SEAMS & PERIMETER EDGES PROVIDE EXTRUDED POLYSTYRENE IN LIEU OF BATT
CONTINUOUS BEAD INSULATION, BEHIND, BENEATH, OR ADJACENT TO
OF SEALANT CONDITIONED ROOF SYSTEM RE: PLUMBING, MECHANICAL, AND ELECTRICAL SUPPLIES,
SPACE FOR STRUCT. RETURNS, AND OTHER DISTRIBUTION LINES AND FIXTURES
MECHANICAL & ATTIC TO ENSURE THE MINIMUM INSULATION VALUES ARE
PLUMBING RUNS INSULATION STRICTLY ADHERED TO IN ALL LOCATIONS. IN ALL
AIR BARRIER - SEAL INACCESSIBLE OR ENCLOSED AREAS OR AREAS THAT MAY
@ SEAMS & BE INACCESSIBLE OR MAY BE ENCLOSED, PLACE
PERIMETER EDGES EXTRUDED POLYSTYRENE INSULATION IMMEDIATELY
PRIOR TO PLACING THE PLUMBING, MECHANICAL, AND
ELECTRICAL RUNS.

ATTIC ACCESS PANELS SHALL BE EQUIPPED WITH A DURABLE,


DROPPED SOFFIT - INSULATED COVER THAT IS GASKETED TO PRODUCE A
EXTERIOR FLOOR AIR BARRIER - CONTINUOUS AIR SEAL WHEN CLOSED, PER N1102.2.4.
AIR BARRIER - SEAL @ AIR BARRIER - SEAL @ CONTINUOUS
INSULATION TO BE
SEAMS & PERIMETER SEAMS & PERIMETER EXTERIOR WALL ALL ELECTRICAL BOXES, LIGHT CANS, AND OTHER
IN CONTACT W/ THE
EDGES EDGES SHEATHING BEHIND PENETRATIONS AT THE CEILING ADJACENT TO
FLOOR DECK
ROOF SYSTEM - UNCONDITIONED ATTIC SPACE SHALL BE FULLY GASKETED
ABOVE
NON-VENTED SEAL @ SEAMS & AND SEALED, PER N1102.4.5 AND TABLE N1102.4.1.1.
GYPSUM BOARD GYPSUM BOARD
SOFFIT, RE: PLANS PERIMETER EDGES
INSULATE ALL CANTILEVERED FLOORS WITH INSULATION,
FOR RATED EXTERIOR WALL EXTERIOR WALL SUFFICIENT TO FILL THE FRAMING CAVITY AND PROVIDE
ASSEMBLIES AND INSULATION INSULATION CLASS I OR II VAPOR RETARDERS ON THE INTERIOR SIDE
LOCATIONS OF FRAME, RE: R702.7 AND TABLE N1102.4.1.1.
EXTERIOR WALL EXTERIOR WALL FLOOR
SHEATHING SHEATHING INSULATION
REFER TO THE GENERAL NOTES INSULATION TABLE
BLOCKING EXTERIOR WALL LOCATED ON THE COVER SHEET FOR EITHER
BETWEEN JOISTS INSULATION PRESCRIPTIVE PATH (CODE MINIMUM) OR ANTICIPATED
PERFORMANCE PATH INSULATION VALUES (PER PROJECT
ENERGY REPORT). RE: N1102.1 AND TABLE N1102.1.2.

1311
CANTILEVER DROPPED SOFFIT 1305
SOFFIT TO FLOOR & ATTIC 1304
SIDE ROOF & KNEE WALL

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


SCALE: NTS (1308 COMBINED IN 1304) SCALE: NTS

PHONE: 303-770-8300
SECTION VIEW SECTION VIEW SECTION VIEW
EXTERIOR WALL
SHEATHING

INSULATION SUFFICIENT FLOOR SHEATHING


TO FILL WALL CAVITY OVER JOIST
EXTERIOR ROOF
GYP BD WITH BLOCKING
SHEATHING
CONTINUOUS SEALANT BETWEEN
ROOF TRUSSES AT BOTTOM OF JOISTS, SEALED
RE: STRUCT. BLOCKING FRAMED WALL AT PERIMETER
BETWEEN
2x10 BOX FRAMED JOISTS, SEALED BOTTOM PLATE W/
CONTINUOUS CAULKING FLOOR INSULATION TO
INSULATION STOP ON AT PERIMETER
AT FLOOR CONNECTION BE IN CONTACT AT ALL
BOTTOM CHORD OF
SIX SIDES, SEAL AT
TRUSS & BLOCKED
PERIMETER AND SEAMS
BETWEEN TRUSS BAY
FLOOR INSULATION
ATTIC INSULATION TO BE IN CONTACT
W/ THE FLOOR
DECK ABOVE

NON-VENTED
TIGHT FITTING ATTIC BATT SOFFIT, RE: PLANS
INSULATION GLUED OR FOR RATED
FASTENED W/ BOLTS AND ASSEMBLIES AND
WIRES TO ACCESS PANEL LOCATIONS
ATTIC ACCESS PANEL -
FIRE PROTECTION
DRYWALL EVEN CUT EDGES
AT FLOOR PER IRC
W/ 1/4" TO 1/2" CLEARANCE SEALANT, ADHESIVE OR GASKET
EXTERIOR WALL
FROM TRUSS @ PERIMETER TAPED OR
INSULATION INSULATION PER ENERGY REPORT
- OPTION FOR ACCESS PANEL SEALED JOINTS
STABILITY FASTEN SHEATHING GYPSUM BOARD
BACKER PANEL
AIR BARRIER - CONTINUOUS TRIM MOULDING
GASKET OR WEATHER STRIP @
PERIMETER OF ACCESS PANEL

1x2 VERTICAL TRIM MOULDING


FASTENED TO TRUSS FOR
ACCESS PANEL SUPPORT
BLOCKING AT
0000
ATTIC ACCESS 1309
CANTILEVER 0000
CONDITIONED SPACE
SCALE: NTS SCALE: NTS SCALE: NTS

SECTION VIEW SECTION VIEW SECTION VIEW

EXTERIOR WALL
SHEATHING

EXTERIOR WALL EXTERIOR ROOF


INSULATION EXTERIOR WALL SHEATHING
SHEATHING
GYPSUM BOARD ROOF TRUSSES
EXTERIOR WALL RE: STRUCT.
INSULATION
CONTINUOUS BEAD ATTIC INSULATION
OF SEALANT GYPSUM BOARD

CONCRETE SLAB ON
GRADE RE: STRUCT. CONTINUOUS BEAD
OF SEALANT
CONTINUOUS 1/2"
EXPANSION JOINT MATERIAL
@ SLAB PERIMETER

CONTINUOUS SEAL
@ SILL PLATE
CONTINUOUS
SPRAY FOAM 2x NAILER
RIGID INSULATION @ SEALANT @
FOUNDATION SILL PLATE AIR BARRIER - SEAL @
PERIMETER USE SEAMS & PERIMETER
EXTRUDED EDGES
POLYSTYRENE (XPS) EXTERIOR
FOUNDATION WALL 2x6 KNEE WALL CUT
VAPOR BARRIER / INSULATION TO FIT FLUSH WITH
RADON MITIGATION, INTERIOR EDGE OF
RUN BENEATH SLAB CONTINUOUS SEAL TRUSS W/ EXTERIOR
& EXTEND DOWN @ SILL PLATE WALL INSULATION
FOUNDATION WALL,
PER CODE GYPSUM BOARD

0000
BASE OF WALL - WALKOUT 0000
BASE OF WALL 0000
ATTIC KNEE WALL
SCALE: NTS SCALE: NTS SCALE: NTS

©
SECTION VIEW

Godden|Sudik
A R C H I T E C T S
SEE WHAT COULD BE

EXTERIOR WALL
SHEATHING

INSULATION EXTERIOR WALL


BAFFLE INSULATION

GYPSUM BOARD

STAIR STRINGER

STAIR TREAD

ATTIC INSULATION

AIR BARRIER @
INSIDE OF WALL
BENEATH STAIRS
AND LANDING, CUT
TO FIT AND SEAL
ALL SEAMS &
PERIMETER EDGES
CONTINUOUS BEAD
OF SEALANT

GYPSUM WALL
BOARD

STAIRWELL

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


1310
SCALE: NTS
EXTERIOR WALL
SHEATHING
EXTERIOR WALL
INSULATION

PHONE: 303-770-8300
CONTINUOUS BEAD OF PLAN VIEW PLAN VIEW
ADHESIVE @ BASE OF
SILL PLATE & TOP OF EXTERIOR WALL
RIM JOIST PERIMETER SHEATHING
CONTINUOUS BEAD EXTERIOR WALL
EXTERIOR WALL
OF SEALANT SHEATHING
INSULATION

EXTERIOR WALL GYPSUM BOARD


INSULATION

EXTERIOR WALL EXTERIOR WALL


INSULATION @ RIM INSULATION - FULL
CAVITY

GYPSUM BOARD
AIR BARRIER -
SEAL @ SEAMS &
CONTINUOUS BEAD AIR BARRIER - PERIMETER EDGES
OF SEALANT PROVIDE IC (INSULATION
SEAL @ SEAMS
CONTACT) RATED RECESSED
& PERIMETER
CAN LIGHT WHEN IN ATTIC SPACE
EDGES
ATTIC INSULATION
2x6 EXTERIOR
STUD WALL -
RE: STRUCT.

2x4 HORIZONTAL
LADDER BLOCKING
CONTINUOUS BEAD
OF SEALANT

CONTINUOUS MINIMAL 2x INTERIOR


EXPANDING SPRAY FOAM STUD WALL
@ PERIMETER OF
WINDOW & DOOR FRAME GYPSUM BOARD
CONTINUOUS BEAD
OF SEALANT

CONTINUOUS BEAD OF
ADHESIVE @ BASE OF
SILL PLATE & TOP OF
RIM JOIST PERIMETER FURRED WALL CHASE @ CORNER & DBL. WALL RECESSED CAN LIGHTS IN ATTIC
1306 1301 1111B
CONTINUOUS BEAD SCALE: NTS SCALE: NTS SCALE: NTS
OF SEALANT

FLOOR SYSTEM,
RE: STRUCTURAL
SECTION VIEW

CERAMIC TILE OVER 1/2" WP GYP BD. SECTION VIEW


SOLID SURFACE SHOWER SEAT.
SECTION VIEW
SECURE W/ MASTIC & CAULK @
CONTINUOUS SPRAY PERIMETER TO TILE
FOAM SEALANT @
INSIDE OF SILL PLATE PLYWOOD PLATFORM OVER 2X EXTERIOR WALL
WATERPROOF SHEATHING
FRAMING
TREATED SILL PLATE MEMBRANE
ON CONTINUOUS SILL EXTERIOR WALL
TOP OF DECK
GASKET INSULATION

EXTERIOR FOUNDATION GYP BD WITH


WALL INSULATION - 2x LEDGER CONTINUOUS SEALANT
CONTINUOUS FROM TOP AT TOP OF TUB DECK
OF RIM JOIST TO TOP OF AIR BARRIER - SEAL @ SEAMS
BASEMENT FLOOR & PERIMETER EDGES @
INSIDE OF WALL BEHIND TUB
CONTINUOUS BEAD EXTERIOR WALL EXTERIOR WALL
CONCRETE FOUNDATION WALL, OF SEALANT SHEATHING SHEATHING
RE: STRUCTURAL PLANS EXTERIOR WALL
SHEATHING 2X BLOCKING, FIELD VERIFY GYPSUM BOARD GYPSUM BOARD
CONTINUOUS 1/2" EXPANSION JOINT
EXTERIOR WALL TUB OR SHOWER PAN
MATERIAL @ SLAB PERIMETER
INSULATION EXTERIOR WALL EXTERIOR WALL
AIR BARRIER - SEAL
CONCRETE SLAB OR INSULATION INSULATION
@ SEAMS &
STRUCTURAL FLOOR, RE: CONTINUOUS PERIMETER EDGES
STRUCTURAL PLANS RIGID INSULATION FILL CAVITY W/
BEAD OF @ INSIDE OF WALL
SEALANT INSULATION
BEHIND TUB
WINDOW OR DOOR WINDOW OR DOOR
HEADER RE: HEADER RE:
CONTINUOUS BEAD STRUCT. STRUCT.
DRIP EDGE OF SEALANT
SILICONE CAULK

0000
WALL SECTION 1303
SHOWER SEAT 1302B
TUB & SHOWER 0000
WINDOW - DOOR HEADER
SCALE: NTS SCALE: NTS SCALE: NTS SCALE: NTS

©
ELECTRICAL SYMBOLS ELECTRICAL NOTES

STANDARD DUPLEX OUTLET 2020 NATIONAL ELECTRICAL CODE (NEC)


AND COMPLIANCE WITH THE 2018 IRC
GFI DUPLEX OUTLET
- GROUND FAULT CIRCUIT INTERUPTER REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION
WP NOT SHOWN OR NOTED ON PLANS.
DUPLEX OUTLET - GFI & WEATHER PROOF
GFI
ALL ELECTRICAL OUTLETS, LIGHT FIXTURES, FANS, SWITCHES,
SWITCHED DUPLEX OUTLET ETC..., SHALL COMPLY W/ 2020 NEC. Godden|Sudik
DWELLING UNIT RECEPTACLE OUTLETS ARE SHOWN FOR
FLOOR OUTLET
REPRESENTATION PURPOSES ONLY, ACTUAL LOCATIONS TO
A R C H I T E C T S
220 VOLT OUTLET COMPLY, PER 210.52 THROUGH 210.65 SEE WHAT COULD BE
BUILDER TO COORDINATE LOCATION OF GAS, WATER &
DUPLEX OUTLET IN CEILING
ELECTRICAL METER & PANEL LOCATIONS.
DIRECT WIRE VERIFY POWER REQUIREMENTS W/ APPLIANCE/
EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
EXHAUST FAN &
EXHAUST FAN
LIGHT COMBINATION
IN EVERY KITCHEN, FAMILY RM., DINING RM., LIVING RM.,
TV CABLE TELEVISION OUTLET PARLOR, LIBRARY, DEN, SUN RM., BDRM., REC. RM., OR SIMILAR
- BUILDER TO VERIFY LOCATION ROOM OR AREA OF DWELLING UNITS, RECEPTACLE OUTLETS
TV - HIGH & LOW OUTLET & "SMURF TUBE" CONNECTOR SHALL BE INSTALLED AS SPECIFIED IN 210.52
OR SIMILAR STACKED @ 12" A.F.F. & 50" A.F.F. - (A)(1) THROUGH (A)(4).
INTEGRATED COMMUNICATION PORT RECEPTACLES SHALL BE INSTALLED SO THAT NO
(CABLE/DATA/PHONE) @ 12" A.F.F. POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF
- BUILDER TO VERIFY SPEC'S. & LOCATION ANY WALL SPACE IS MORE THAN 6'-0" FROM A RECEPTACLE
OUTLET, THAT DO NOT HAVE COUNTERTOPS OR SIMILAR WORK
INTEGRATED COMMUNICATION JACK SPACES, PER 210.52(A)(1)(2).
- INCLUDES (2) PHONE & (2) CABLE OUTLETS RECEPTACLE OUTLETS IN FLOORS
- BUILDER TO VERIFY SPEC'S. & LOCATION SHALL NOT BE COUNTED AS PART OF THE REQUIRED NUMBER
TELEPHONE JACK OF RECEPTACLE OUTLETS EXCEPT WHERE LOCATED WITHIN
- BUILDER TO VERIFY LOCATION 18" OF THE WALL, PER 210.52(A)(3).
OUTLETS IN FLOORS, TEL. JACKS AND TELEVISION LOCATIONS
TELEPHONE JACK PRE-WIRE TO BE FIELD VERIFIED BY BUILDER.
- BUILDER TO VERIFY LOCATION
IN THE KITCHEN, PANTRY, BREAKFAST AREA, DINING ROOM OR
ICC-ES SMOKE DETECTOR SIMILAR AREA OF A DWELLING UNIT, TWO OR MORE 20-AMPERE
D SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY
- LINK AUDIO TO OTHER UNITS
210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE
C CARBON MONOXIDE DETECTOR OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP AND WORK
SURFACE OUTLETS COVERED BY 210.52(C), AND RECEPTACLE
X CARBON MONOXIDE & SMOKE DETECTOR COMBINATION OUTLETS FOR REFRIGERATION EQUIPTMENT, PER 210.52(B)(1).
AT LEAST ONE ADDITIONAL 20-AMPERE BRANCH CIRCUIT SHALL
J JUNCTION BOX BE PROVIDED TO SUPPLY THE LAUNDRY RECEPTACLE
OUTLET(S) REQUIRED BY 210.52(F), PER 210.11(C)(2).
S SINGLE SWITCH
ONE OR MORE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL
S3 3-WAY SWITCH BE PROVIDED TO SUPPLY A BATHROOM(S) RECEPTACLE
OUTLET(S). REQUIRED BY 210.52 (D) AND ANY COUNTERTOP
S4 4-WAY SWITCH AND SIMILAR WORK SURFACE RECEPTACLE OUTLETS PER
SD DIMMER SWITCH 210.11(C)(3).
GFCI PROTECTION SHALL BE PROVIDED FOR OUTLETS THAT
SURFACED MOUNTED CEILING LIGHT FIXTURE - SUPPLY SUMP PUMPS AND DISHWASHERS PER 210.8(D) AND
STYLE PER BUILDER SPECIFICATIONS 422.5.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


ALL SERVICES SUPPLYING DWELLING
PENDANT OR CHANDELIER LIGHT FIXTURE UNITS SHALL BE PROVIDED WITH A SURGE-PROTECTION
- STYLE PER BUILDER SPECIFICATIONS DEVICE (SPD) PER 230.67. THE SPD SHALL BE TYPE I OR II.
PC
PULL-CHAIN CEILING LIGHT FIXTURE GFCI FOR PERSONNEL SHALL BE PROVIDED AS REQUIRED, PER
210.8(A) THROUGH (F). THE GFCI SHALL BE INSTALLED IN A
READILY ACCESSIBLE LOCATION.
LED PUCK CEILING LIGHT FIXTURE
:

S
RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE

PHONE: 303-770-8300
WP
LED PUCK CEILING LIGHT FIXTURE - WATER PROOF WITH 210.52 (C)(2)(A) AND (C)(2)(B). AT LEAST ONE RECEPTACLE
OUTLET SHALL BE PROVIDED FOR THE FIRST 9 SQ. FT. OF THE
COUNTERTOP OR WORK SURFACE AND WITHIN THE LOCATION
LED PUCK MINI CEILING LIGHT FIXTURE PER 210.52 (C)(3).
ALL 125-VOLT THROUGH 250-VOLT, RECEPTACLES INSTALLED IN
LED PUCK DIRECTIONAL CEILING LIGHT FIXTURE THE LOCATIONS SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND
SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150
VOLTS OR LESS TO GROUND SHALL HAVE GFCI PROTECTION
WALL MOUNT SCONCE LIGHT FIXTURE FOR PERSONNEL. INCLUDES BATHROOMS,
- STYLE PER BUILDER SPECIFICATIONS GARAGES, OUTDOORS, CRAWL SPACES, BASEMENTS,
GFI KITCHENS, SINKS, BOATHOUSES, BATHTUBS OR SHOWER
WALL MOUNT LIGHT FIXTURE
STALLS - WITHIN 6 FEET OF THE OUTSIDE EDGE OF BATHTUBS
- COACH, LANTERN, CARRIAGE, ETC...
OR SHOWER STALLS, LAUNDRY AREAS AND INDOOR DAMP AND
- STYLE PER BUILDER SPECIFICATIONS
WET LOCATIONS PER 210.8 (A).
WALL MOUNT VANITY LIGHT FIXTURE
- LIGHT BAR - AFCI SHALL BE PROVIDED AS REQUIRED, PER 210.12(A)(B)
- STYLE AND FIXTURE SIZE / BULB COUNT PER (C) AND (D). THE AFCI SHALL BE INSTALLED IN A READILY
BUILDER SPECIFICATIONS ACCESSIBLE LOCATION.
ALL 120-VOLT, SINGLE-PHASE, 15-AMPERE AND 20-AMPERE
BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES
5-LIGHT WALL MOUNT VANITY LIGHT FIXTURE INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS,
- LIGHT BAR - DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
- STYLE PER BUILDER SPECIFICATIONS BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS OR AREAS
SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN
DB DOOR BELL - PUSH BUTTON 210.12(A)(1) THROUGH (6), (B)(C)(D).
AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE
GD GARAGE DOOR OPENER - PUSH BUTTON INSTALLED IN BATHROOMS WITHIN 3'-0" OF THE OUTSIDE EDGE
TO LIGHT
OF EACH BASIN. THE RECEPTACLE OUTLET SHALL BE LOCATED
& SWITCH LED LIGHT -
B CHIME - BELL LED ON A WALL OR PARTITION THAT IS ADJACENT TO THE BASIN OR
ABOVE SIZE PER PLAN BASIN COUNTERTOP, LOCATED ON THE COUNTERTOP, OR
LIGHT
T THERMOSTAT & BLDR. SPEC'S. INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET. IN
NO CASE SHALL THE RECEPTACLE BE LOCATED MORE THAN 12"
CEILING FAN BELOW THE TOP OF THE BASIN OR COUNTERTOP. RECEPTACLE
- INSTALL LIGHT KIT IF NOTED OUTLET ASSEMBLIES LISTED FOR USE IN COUNTERTOPS SHALL
- PER BUILDER SPECIFICATIONS BE PERMITTED TO BE INSTALLED IN THE COUNTERTOP, PER
WP 210.52(D).
GFI CEILING FAN - (SYMBOL DASHED) TYPICAL OUTLETS TO BE INSTALLED AT +12" A.F.F. U.N.O. -
RE: ROUGH-IN FOR OPTIONAL OUTLETS LOCATED AT +36" H. COUNTERTOPS TO BE INSTALLED
FAN AND LIGHT COMBINATION AT +48" A.F.F. U.N.O. - OUTLETS LOCATED AT +30" H.
COUNTERTOPS TO BE INSTALLED AT +42" A.F.F. U.N.O. -
BREAKER PANEL - BUILDER LOCATE PER SITE OUTLETS INDICATED AT ENTERTAINMENT / AUDIO CENTERS
SPECIFIC CONDITIONS ARE TO BE COORDINATED W/ MILLWORK SUBCONTRACTOR &

S S3
AUDIO VISUAL CONSULTANT.
IN DWELLING UNITS, LIGHTING OUTLETS SHALL BE INSTALLED
WHERE SPECIFIED IN 210.70(A)(B) AND (C).
:
RECESSED LIGHT FIXTURES, AND OTHER
S AT OPT. ALL LIGHTING REQUIREMENTS SHALL BE IN COMPLIANCE WITH
3 SIMILAR FIXTURES, INSTALLED IN THE BUILDING THERMAL
ARTICLE 410.
WALKOUT ENVELOPE SHALL BE AIR TIGHT, "IC" RATED, AND SEALED TO
THE DRYWALL, PER TABLE N1102.4.1.1. : ARE TO BE INSTALLED IN ACCORDANCE WITH
SINGLE GFI OUTLET MANUFACTURER'S INSTRUCTIONS AND PER ARTICLE 760.
X DWELLING UNITS,
AT SUMP PIT (FIELD PROVIDE ALARMS IN THE FOLLOWING LOCATIONS:
VERIFY LOCATION) INCLUDING ATTACHED AND DETACHED GARAGES AND 1. IN EACH SLEEPING ROOM.
ACCESSORY BUILDINGS SHALL BE LISTED TAMPER 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
WP
-RESISTANT RECEPTABLES PER 406.12. VICINITY OF THE BEDROOMS.
GFI
SHALL BE INSTALLED IN A 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
READILY ACCESSIBLE OUTDOOR LOCATION. SERVICE BASEMENTS/HABITABLE ATTICS, NOT INCLUDING CRAWL
DISCONNECTS MUST BE MARKED PER 230.85 SPACES AND UNINHABITABLE ATTICS. IN DWELLING UNITS WITH
SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN
S THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE
THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL, UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER
COMMUNICATION BOXES, AND ALL OTHER SIMILAR FIXTURES, LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE
OR AIR-SEALED BOXES SHALL BE INSTALLED, PER TABLE FULL STORY BELOW THE UPPER LEVEL.
N1102.4.1.1. 4. NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR
MECHANICAL VENTILATION SYSTEMS ARE TO BE OPENING OF A BATHROOM WITH A BATHTUB OR SHOWER.
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S 5. INSTALLATION HORIZONTALLY FROM PERMANENTLY
INSTRUCTIONS, THE 2020 NEC AND THE 2018 IRC R303.4 AND INSTALLED COOKING APPLIANCES:
R303.5. - NOT LESS THAN 20' FOR IONIZATION SMOKE ALARMS.
- NOT LESS THAN 10' FOR IONIZATION SMOKE ALARMS
SHALL DISCHARGE TO THE OUTDOORS WITH AN ALARM-SILENCING SWITCH.
THROUGH A SINGLE WALL DUCT. THE DUCT SERVING THE - NOT LESS THAN 6' FOR PHOTOELECTRIC SMOKE ALARMS.
HOOD SHALL HAVE A SMOOTH INTERIOR, BE AIR TIGHT, BE : ARE TO BE INSTALLED IN
EQUIPTED WITH A BACK DRAFT DAMPER AND BE INDEPENDENT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
GFI OF ALL OTHER EXHAUST SYSTEMS. DUCTS SHALL NOT PER ARTICLE 760. PROVIDE CARBON MONOXIDE ALARMS IN THE
TERMINATE IN ATTICS, CRAWL SPACES OR AREAS INSIDE THE FOLLOWING LOCATIONS:
BUILDING, PER M1503.1. - ON THE CEILING OR WALL WITHIN 15'-0" OF THE ENTRANCE
TO EACH SEPARATE SLEEPING AREA.
KITCHEN EXHAUST RATES SHALL COMPLY WITH M1503.5. - IN THE BEDROOM WHERE A FUEL-BURNING APPLIANCE IS
LOCATED OR ITS ATTACHED BATHROOM.
MAKEUP AIR IS REQUIRED TO AN EXHAUST HOOD SYSTEM - ON EVERY FLOOR LEVEL.
CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM AND SHALL IN ADDITION, A CARBON MONOXIDE DETECTOR CAN BE
BE MECHANICALLY OR NATURALLY PROVIDED WITH A MAKEUP INSTALLED WITHIN 25'-0" OF ANY FUEL-FIRED HEATER, BOILER,
AIR RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. FIREPLACE OR ATTACHED GARAGE AS LONG AS THERE IS A
PROVIDE NOT LESS THAN ONE GRAVITY OR ELECTRICALLY CENTRALIZED ALARM SYSTEM OR OTHER MECHANISM FOR A
OPERATED DAMPER, PER M1503.6. RESPONSIBLE PERSON TO HEAR THE ALARM AT ALL TIMES.
: COMBINATION SMOKE AND CARBON
DOMESTIC OPEN-TOP BROILER MONOXIDE ALARMS SHALL BE PERMITTED TO USE IN PLACE OF
UNITS SHALL HAVE A METAL EXHAUST HOOD AND DISCHARGE SMOKE ALARMS OR CARBON MONOXIDE ALARMS.
TO THE OUTDOORS EQUIPPED WITH A BACK DRAFT DAMPER
OR OTHER MEANS TO CONTROL INFILTRATION/EXFILTRATION PER COLORADO'S HOUSE BILL 1149 ENACTED INTO LAW,
WHEN NOT IN OPERATION. BOILER UNITS INCORPORATING AN REQUIRES THE BUILDER THE OPTION OF HAVING THE HOME
INTEGRAL EXHAUST SYSTEM, DOES NOT REQUIRE AN INCLUDE OR BE PRE-WIRED FOR SOLAR PHOTOVOLTAIC
EXHAUST HOOD, PER M1503.1. INSTALLATION. ALSO PROVIDED TO THE HOMEOWNERS PER
THE REQUIREMENTS OF THE LAW IS A LIST OF LOCAL SOLAR

LOWER LEVEL ELECTRICAL PLAN :


SHALL BE DESIGNED IN ACCORDANCE WITH SECTIONS M1505.4.
INSTALLERS/CONTRACTORS WHO CAN ASSESS THE HOME'S

1
SOLAR ENERGY POTENTIAL.

SCALE: 1/4" = 1'-0" BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY PROVIDE FULL LENGTH CONDUIT TUBE FROM BASEMENT TO
ROOMS AND SIMILAR ROOMS SHALL BE PROVIDED WITH ATTIC, PRE-WIRE FOR SOLAR PHOTOVOLTAIC (PV) SYSTEM
NATURAL VENTILATION W/ AN AREA NOT LESS THAN 1 1/2 SF - INSTALLATION. COORDINATED PER BUILDER.
IN BATHROOMS, LAUNDRY ROOMS AND SIMILAR ROOMS, THE SOLAR (PV) SYSTEM TO BE INSTALLED IN ACCORDANCE
WITHOUT NATURAL VENTILATION, A MECHANICAL VENTILATION WITH MANUFACTURER'S INSTRUCTIONS AND SHALL COMPLY
SYSTEM CONNECTED DIRECTLY TO EXTERIOR CAPABLE OF WITH ARTICLE 690
VENTILATION RATES OF 50 CFM INTERMITTENT OR 20 CFM : A MINIMUM OF 90% OF
CONTINUOUS FOR BATHROOMS, TOILET ROOMS SHALL BE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
PROVIDED. A MECHANICAL VENTILATION SYSTEM WITH BE HIGH-EFFICACY LAMPS, PER N1104.1
VENTILATION RATES OF 100 CFM INTERMITTENT OR 25 CFM
CONTINUOUS FOR KITCHENS SHALL BE PROVIDED, PER
M1505.4.

: ALL BATH FANS MUST MEET ENERGY STAR V3.2


REQUIREMENTS EFFECTIVE JAN 2021

©
ELECTRICAL SYMBOLS ELECTRICAL NOTES

STANDARD DUPLEX OUTLET 2020 NATIONAL ELECTRICAL CODE (NEC)


AND COMPLIANCE WITH THE 2018 IRC
GFI DUPLEX OUTLET
- GROUND FAULT CIRCUIT INTERUPTER REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION
WP NOT SHOWN OR NOTED ON PLANS.
DUPLEX OUTLET - GFI & WEATHER PROOF
GFI
ALL ELECTRICAL OUTLETS, LIGHT FIXTURES, FANS, SWITCHES,
SWITCHED DUPLEX OUTLET ETC..., SHALL COMPLY W/ 2020 NEC. Godden|Sudik
DWELLING UNIT RECEPTACLE OUTLETS ARE SHOWN FOR
FLOOR OUTLET
REPRESENTATION PURPOSES ONLY, ACTUAL LOCATIONS TO
A R C H I T E C T S
220 VOLT OUTLET COMPLY, PER 210.52 THROUGH 210.65 SEE WHAT COULD BE
BUILDER TO COORDINATE LOCATION OF GAS, WATER &
DUPLEX OUTLET IN CEILING
ELECTRICAL METER & PANEL LOCATIONS.
DIRECT WIRE VERIFY POWER REQUIREMENTS W/ APPLIANCE/
EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
EXHAUST FAN &
EXHAUST FAN
LIGHT COMBINATION
IN EVERY KITCHEN, FAMILY RM., DINING RM., LIVING RM.,
TV CABLE TELEVISION OUTLET PARLOR, LIBRARY, DEN, SUN RM., BDRM., REC. RM., OR SIMILAR
- BUILDER TO VERIFY LOCATION ROOM OR AREA OF DWELLING UNITS, RECEPTACLE OUTLETS
TV - HIGH & LOW OUTLET & "SMURF TUBE" CONNECTOR SHALL BE INSTALLED AS SPECIFIED IN 210.52
OR SIMILAR STACKED @ 12" A.F.F. & 50" A.F.F. - (A)(1) THROUGH (A)(4).
INTEGRATED COMMUNICATION PORT RECEPTACLES SHALL BE INSTALLED SO THAT NO
(CABLE/DATA/PHONE) @ 12" A.F.F. POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF
- BUILDER TO VERIFY SPEC'S. & LOCATION ANY WALL SPACE IS MORE THAN 6'-0" FROM A RECEPTACLE
OUTLET, THAT DO NOT HAVE COUNTERTOPS OR SIMILAR WORK
INTEGRATED COMMUNICATION JACK SPACES, PER 210.52(A)(1)(2).
- INCLUDES (2) PHONE & (2) CABLE OUTLETS RECEPTACLE OUTLETS IN FLOORS
- BUILDER TO VERIFY SPEC'S. & LOCATION SHALL NOT BE COUNTED AS PART OF THE REQUIRED NUMBER
TELEPHONE JACK OF RECEPTACLE OUTLETS EXCEPT WHERE LOCATED WITHIN
- BUILDER TO VERIFY LOCATION 18" OF THE WALL, PER 210.52(A)(3).
OUTLETS IN FLOORS, TEL. JACKS AND TELEVISION LOCATIONS
TELEPHONE JACK PRE-WIRE TO BE FIELD VERIFIED BY BUILDER.
- BUILDER TO VERIFY LOCATION
IN THE KITCHEN, PANTRY, BREAKFAST AREA, DINING ROOM OR
ICC-ES SMOKE DETECTOR SIMILAR AREA OF A DWELLING UNIT, TWO OR MORE 20-AMPERE
D SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY
- LINK AUDIO TO OTHER UNITS
210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE
C CARBON MONOXIDE DETECTOR OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP AND WORK
SURFACE OUTLETS COVERED BY 210.52(C), AND RECEPTACLE
X CARBON MONOXIDE & SMOKE DETECTOR COMBINATION OUTLETS FOR REFRIGERATION EQUIPTMENT, PER 210.52(B)(1).
AT LEAST ONE ADDITIONAL 20-AMPERE BRANCH CIRCUIT SHALL
J JUNCTION BOX BE PROVIDED TO SUPPLY THE LAUNDRY RECEPTACLE
OUTLET(S) REQUIRED BY 210.52(F), PER 210.11(C)(2).
S SINGLE SWITCH
ONE OR MORE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL
S3 3-WAY SWITCH BE PROVIDED TO SUPPLY A BATHROOM(S) RECEPTACLE
OUTLET(S). REQUIRED BY 210.52 (D) AND ANY COUNTERTOP
S4 4-WAY SWITCH AND SIMILAR WORK SURFACE RECEPTACLE OUTLETS PER
SD DIMMER SWITCH 210.11(C)(3).
GFCI PROTECTION SHALL BE PROVIDED FOR OUTLETS THAT
SURFACED MOUNTED CEILING LIGHT FIXTURE - SUPPLY SUMP PUMPS AND DISHWASHERS PER 210.8(D) AND
STYLE PER BUILDER SPECIFICATIONS 422.5.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


ALL SERVICES SUPPLYING DWELLING
PENDANT OR CHANDELIER LIGHT FIXTURE UNITS SHALL BE PROVIDED WITH A SURGE-PROTECTION
- STYLE PER BUILDER SPECIFICATIONS DEVICE (SPD) PER 230.67. THE SPD SHALL BE TYPE I OR II.
PC
PULL-CHAIN CEILING LIGHT FIXTURE GFCI FOR PERSONNEL SHALL BE PROVIDED AS REQUIRED, PER
210.8(A) THROUGH (F). THE GFCI SHALL BE INSTALLED IN A
READILY ACCESSIBLE LOCATION.
LED PUCK CEILING LIGHT FIXTURE
:
RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE

PHONE: 303-770-8300
WP
LED PUCK CEILING LIGHT FIXTURE - WATER PROOF WITH 210.52 (C)(2)(A) AND (C)(2)(B). AT LEAST ONE RECEPTACLE
OUTLET SHALL BE PROVIDED FOR THE FIRST 9 SQ. FT. OF THE
COUNTERTOP OR WORK SURFACE AND WITHIN THE LOCATION
LED PUCK MINI CEILING LIGHT FIXTURE PER 210.52 (C)(3).
ALL 125-VOLT THROUGH 250-VOLT, RECEPTACLES INSTALLED IN
LED PUCK DIRECTIONAL CEILING LIGHT FIXTURE THE LOCATIONS SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND
SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150
VOLTS OR LESS TO GROUND SHALL HAVE GFCI PROTECTION
WALL MOUNT SCONCE LIGHT FIXTURE FOR PERSONNEL. INCLUDES BATHROOMS,
- STYLE PER BUILDER SPECIFICATIONS GARAGES, OUTDOORS, CRAWL SPACES, BASEMENTS,
KITCHENS, SINKS, BOATHOUSES, BATHTUBS OR SHOWER
WALL MOUNT LIGHT FIXTURE
STALLS - WITHIN 6 FEET OF THE OUTSIDE EDGE OF BATHTUBS
- COACH, LANTERN, CARRIAGE, ETC...
OR SHOWER STALLS, LAUNDRY AREAS AND INDOOR DAMP AND
- STYLE PER BUILDER SPECIFICATIONS
WET LOCATIONS PER 210.8 (A).
WALL MOUNT VANITY LIGHT FIXTURE
- LIGHT BAR - AFCI SHALL BE PROVIDED AS REQUIRED, PER 210.12(A)(B)
- STYLE AND FIXTURE SIZE / BULB COUNT PER (C) AND (D). THE AFCI SHALL BE INSTALLED IN A READILY
BUILDER SPECIFICATIONS ACCESSIBLE LOCATION.
ALL 120-VOLT, SINGLE-PHASE, 15-AMPERE AND 20-AMPERE
BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES
5-LIGHT WALL MOUNT VANITY LIGHT FIXTURE INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS,
- LIGHT BAR - DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
- STYLE PER BUILDER SPECIFICATIONS BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS OR AREAS
SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN
DB DOOR BELL - PUSH BUTTON 210.12(A)(1) THROUGH (6), (B)(C)(D).
AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE
GD GARAGE DOOR OPENER - PUSH BUTTON INSTALLED IN BATHROOMS WITHIN 3'-0" OF THE OUTSIDE EDGE
TO LIGHT
OF EACH BASIN. THE RECEPTACLE OUTLET SHALL BE LOCATED
& SWITCH LED LIGHT -
B CHIME - BELL LED ON A WALL OR PARTITION THAT IS ADJACENT TO THE BASIN OR
ABOVE SIZE PER PLAN BASIN COUNTERTOP, LOCATED ON THE COUNTERTOP, OR
LIGHT
T THERMOSTAT & BLDR. SPEC'S. INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET. IN
NO CASE SHALL THE RECEPTACLE BE LOCATED MORE THAN 12"
CEILING FAN BELOW THE TOP OF THE BASIN OR COUNTERTOP. RECEPTACLE
- INSTALL LIGHT KIT IF NOTED OUTLET ASSEMBLIES LISTED FOR USE IN COUNTERTOPS SHALL
- PER BUILDER SPECIFICATIONS BE PERMITTED TO BE INSTALLED IN THE COUNTERTOP, PER
WP 210.52(D).
GFI CEILING FAN - (SYMBOL DASHED) TYPICAL OUTLETS TO BE INSTALLED AT +12" A.F.F. U.N.O. -
RE: ROUGH-IN FOR OPTIONAL OUTLETS LOCATED AT +36" H. COUNTERTOPS TO BE INSTALLED
FAN AND LIGHT COMBINATION AT +48" A.F.F. U.N.O. - OUTLETS LOCATED AT +30" H.
COUNTERTOPS TO BE INSTALLED AT +42" A.F.F. U.N.O. -
BREAKER PANEL - BUILDER LOCATE PER SITE OUTLETS INDICATED AT ENTERTAINMENT / AUDIO CENTERS
SPECIFIC CONDITIONS ARE TO BE COORDINATED W/ MILLWORK SUBCONTRACTOR &

S S3
AUDIO VISUAL CONSULTANT.
IN DWELLING UNITS, LIGHTING OUTLETS SHALL BE INSTALLED
WHERE SPECIFIED IN 210.70(A)(B) AND (C).
:
RECESSED LIGHT FIXTURES, AND OTHER
ALL LIGHTING REQUIREMENTS SHALL BE IN COMPLIANCE WITH
AT OPT. SIMILAR FIXTURES, INSTALLED IN THE BUILDING THERMAL
ARTICLE 410.
WALKOUT ENVELOPE SHALL BE AIR TIGHT, "IC" RATED, AND SEALED TO
THE DRYWALL, PER TABLE N1102.4.1.1. : ARE TO BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS AND PER ARTICLE 760.
X DWELLING UNITS, PROVIDE ALARMS IN THE FOLLOWING LOCATIONS:
INCLUDING ATTACHED AND DETACHED GARAGES AND 1. IN EACH SLEEPING ROOM.
ACCESSORY BUILDINGS SHALL BE LISTED TAMPER 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
-RESISTANT RECEPTABLES PER 406.12. VICINITY OF THE BEDROOMS.
SHALL BE INSTALLED IN A 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
READILY ACCESSIBLE OUTDOOR LOCATION. SERVICE BASEMENTS/HABITABLE ATTICS, NOT INCLUDING CRAWL
DISCONNECTS MUST BE MARKED PER 230.85 SPACES AND UNINHABITABLE ATTICS. IN DWELLING UNITS WITH
SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN
THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE
THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL, UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER
COMMUNICATION BOXES, AND ALL OTHER SIMILAR FIXTURES, LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE
OR AIR-SEALED BOXES SHALL BE INSTALLED, PER TABLE FULL STORY BELOW THE UPPER LEVEL.
N1102.4.1.1. 4. NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR
MECHANICAL VENTILATION SYSTEMS ARE TO BE OPENING OF A BATHROOM WITH A BATHTUB OR SHOWER.
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S 5. INSTALLATION HORIZONTALLY FROM PERMANENTLY
INSTRUCTIONS, THE 2020 NEC AND THE 2018 IRC R303.4 AND INSTALLED COOKING APPLIANCES:
R303.5. - NOT LESS THAN 20' FOR IONIZATION SMOKE ALARMS.
- NOT LESS THAN 10' FOR IONIZATION SMOKE ALARMS
SHALL DISCHARGE TO THE OUTDOORS WITH AN ALARM-SILENCING SWITCH.
THROUGH A SINGLE WALL DUCT. THE DUCT SERVING THE - NOT LESS THAN 6' FOR PHOTOELECTRIC SMOKE ALARMS.
HOOD SHALL HAVE A SMOOTH INTERIOR, BE AIR TIGHT, BE : ARE TO BE INSTALLED IN
EQUIPTED WITH A BACK DRAFT DAMPER AND BE INDEPENDENT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
OF ALL OTHER EXHAUST SYSTEMS. DUCTS SHALL NOT PER ARTICLE 760. PROVIDE CARBON MONOXIDE ALARMS IN THE
SINGLE GFI OUTLET TERMINATE IN ATTICS, CRAWL SPACES OR AREAS INSIDE THE FOLLOWING LOCATIONS:
AT SUMP PIT (FIELD BUILDING, PER M1503.1. - ON THE CEILING OR WALL WITHIN 15'-0" OF THE ENTRANCE
VERIFY LOCATION) TO EACH SEPARATE SLEEPING AREA.
WP KITCHEN EXHAUST RATES SHALL COMPLY WITH M1503.5. - IN THE BEDROOM WHERE A FUEL-BURNING APPLIANCE IS
GFI LOCATED OR ITS ATTACHED BATHROOM.
MAKEUP AIR IS REQUIRED TO AN EXHAUST HOOD SYSTEM - ON EVERY FLOOR LEVEL.
CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM AND SHALL IN ADDITION, A CARBON MONOXIDE DETECTOR CAN BE
BE MECHANICALLY OR NATURALLY PROVIDED WITH A MAKEUP INSTALLED WITHIN 25'-0" OF ANY FUEL-FIRED HEATER, BOILER,
AIR RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. FIREPLACE OR ATTACHED GARAGE AS LONG AS THERE IS A
PROVIDE NOT LESS THAN ONE GRAVITY OR ELECTRICALLY CENTRALIZED ALARM SYSTEM OR OTHER MECHANISM FOR A
OPERATED DAMPER, PER M1503.6. RESPONSIBLE PERSON TO HEAR THE ALARM AT ALL TIMES.
: COMBINATION SMOKE AND CARBON
DOMESTIC OPEN-TOP BROILER MONOXIDE ALARMS SHALL BE PERMITTED TO USE IN PLACE OF
UNITS SHALL HAVE A METAL EXHAUST HOOD AND DISCHARGE SMOKE ALARMS OR CARBON MONOXIDE ALARMS.
TO THE OUTDOORS EQUIPPED WITH A BACK DRAFT DAMPER
OR OTHER MEANS TO CONTROL INFILTRATION/EXFILTRATION PER COLORADO'S HOUSE BILL 1149 ENACTED INTO LAW,

OPT. FULL WHEN NOT IN OPERATION. BOILER UNITS INCORPORATING AN


INTEGRAL EXHAUST SYSTEM, DOES NOT REQUIRE AN
EXHAUST HOOD, PER M1503.1.
REQUIRES THE BUILDER THE OPTION OF HAVING THE HOME
INCLUDE OR BE PRE-WIRED FOR SOLAR PHOTOVOLTAIC
INSTALLATION. ALSO PROVIDED TO THE HOMEOWNERS PER
THE REQUIREMENTS OF THE LAW IS A LIST OF LOCAL SOLAR

LOWER LEVEL ELECTRICAL PLAN :


SHALL BE DESIGNED IN ACCORDANCE WITH SECTIONS M1505.4.
INSTALLERS/CONTRACTORS WHO CAN ASSESS THE HOME'S

1
SOLAR ENERGY POTENTIAL.

SCALE: 1/4" = 1'-0" BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY PROVIDE FULL LENGTH CONDUIT TUBE FROM BASEMENT TO
ROOMS AND SIMILAR ROOMS SHALL BE PROVIDED WITH ATTIC, PRE-WIRE FOR SOLAR PHOTOVOLTAIC (PV) SYSTEM
NATURAL VENTILATION W/ AN AREA NOT LESS THAN 1 1/2 SF - INSTALLATION. COORDINATED PER BUILDER.
IN BATHROOMS, LAUNDRY ROOMS AND SIMILAR ROOMS, THE SOLAR (PV) SYSTEM TO BE INSTALLED IN ACCORDANCE
WITHOUT NATURAL VENTILATION, A MECHANICAL VENTILATION WITH MANUFACTURER'S INSTRUCTIONS AND SHALL COMPLY
SYSTEM CONNECTED DIRECTLY TO EXTERIOR CAPABLE OF WITH ARTICLE 690
VENTILATION RATES OF 50 CFM INTERMITTENT OR 20 CFM : A MINIMUM OF 90% OF
CONTINUOUS FOR BATHROOMS, TOILET ROOMS SHALL BE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
PROVIDED. A MECHANICAL VENTILATION SYSTEM WITH BE HIGH-EFFICACY LAMPS, PER N1104.1
VENTILATION RATES OF 100 CFM INTERMITTENT OR 25 CFM
CONTINUOUS FOR KITCHENS SHALL BE PROVIDED, PER
M1505.4.

: ALL BATH FANS MUST MEET ENERGY STAR V3.2


REQUIREMENTS EFFECTIVE JAN 2021

©
ELECTRICAL SYMBOLS ELECTRICAL NOTES

STANDARD DUPLEX OUTLET 2020 NATIONAL ELECTRICAL CODE (NEC)


AND COMPLIANCE WITH THE 2018 IRC
GFI DUPLEX OUTLET
- GROUND FAULT CIRCUIT INTERUPTER REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION
WP NOT SHOWN OR NOTED ON PLANS.
DUPLEX OUTLET - GFI & WEATHER PROOF
GFI
ALL ELECTRICAL OUTLETS, LIGHT FIXTURES, FANS, SWITCHES,
SWITCHED DUPLEX OUTLET ETC..., SHALL COMPLY W/ 2020 NEC. Godden|Sudik
DWELLING UNIT RECEPTACLE OUTLETS ARE SHOWN FOR
FLOOR OUTLET
REPRESENTATION PURPOSES ONLY, ACTUAL LOCATIONS TO
A R C H I T E C T S
220 VOLT OUTLET COMPLY, PER 210.52 THROUGH 210.65 SEE WHAT COULD BE
BUILDER TO COORDINATE LOCATION OF GAS, WATER &
DUPLEX OUTLET IN CEILING
ELECTRICAL METER & PANEL LOCATIONS.
DIRECT WIRE VERIFY POWER REQUIREMENTS W/ APPLIANCE/
EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
EXHAUST FAN &
EXHAUST FAN
LIGHT COMBINATION
IN EVERY KITCHEN, FAMILY RM., DINING RM., LIVING RM.,
TV CABLE TELEVISION OUTLET PARLOR, LIBRARY, DEN, SUN RM., BDRM., REC. RM., OR SIMILAR
- BUILDER TO VERIFY LOCATION ROOM OR AREA OF DWELLING UNITS, RECEPTACLE OUTLETS
TV - HIGH & LOW OUTLET & "SMURF TUBE" CONNECTOR SHALL BE INSTALLED AS SPECIFIED IN 210.52
OR SIMILAR STACKED @ 12" A.F.F. & 50" A.F.F. - (A)(1) THROUGH (A)(4).
INTEGRATED COMMUNICATION PORT RECEPTACLES SHALL BE INSTALLED SO THAT NO
(CABLE/DATA/PHONE) @ 12" A.F.F. POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF
- BUILDER TO VERIFY SPEC'S. & LOCATION ANY WALL SPACE IS MORE THAN 6'-0" FROM A RECEPTACLE
OUTLET, THAT DO NOT HAVE COUNTERTOPS OR SIMILAR WORK
INTEGRATED COMMUNICATION JACK SPACES, PER 210.52(A)(1)(2).
- INCLUDES (2) PHONE & (2) CABLE OUTLETS RECEPTACLE OUTLETS IN FLOORS
- BUILDER TO VERIFY SPEC'S. & LOCATION SHALL NOT BE COUNTED AS PART OF THE REQUIRED NUMBER
TELEPHONE JACK OF RECEPTACLE OUTLETS EXCEPT WHERE LOCATED WITHIN
- BUILDER TO VERIFY LOCATION 18" OF THE WALL, PER 210.52(A)(3).
OUTLETS IN FLOORS, TEL. JACKS AND TELEVISION LOCATIONS
TELEPHONE JACK PRE-WIRE TO BE FIELD VERIFIED BY BUILDER.
- BUILDER TO VERIFY LOCATION
IN THE KITCHEN, PANTRY, BREAKFAST AREA, DINING ROOM OR
ICC-ES SMOKE DETECTOR SIMILAR AREA OF A DWELLING UNIT, TWO OR MORE 20-AMPERE
D SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY
- LINK AUDIO TO OTHER UNITS
210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE
C CARBON MONOXIDE DETECTOR OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP AND WORK
SURFACE OUTLETS COVERED BY 210.52(C), AND RECEPTACLE
X CARBON MONOXIDE & SMOKE DETECTOR COMBINATION OUTLETS FOR REFRIGERATION EQUIPTMENT, PER 210.52(B)(1).
AT LEAST ONE ADDITIONAL 20-AMPERE BRANCH CIRCUIT SHALL
J JUNCTION BOX BE PROVIDED TO SUPPLY THE LAUNDRY RECEPTACLE
OUTLET(S) REQUIRED BY 210.52(F), PER 210.11(C)(2).
S SINGLE SWITCH
ONE OR MORE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL
S3 3-WAY SWITCH BE PROVIDED TO SUPPLY A BATHROOM(S) RECEPTACLE
OUTLET(S). REQUIRED BY 210.52 (D) AND ANY COUNTERTOP
S4 4-WAY SWITCH AND SIMILAR WORK SURFACE RECEPTACLE OUTLETS PER
SD DIMMER SWITCH 210.11(C)(3).
GFCI PROTECTION SHALL BE PROVIDED FOR OUTLETS THAT
SURFACED MOUNTED CEILING LIGHT FIXTURE - SUPPLY SUMP PUMPS AND DISHWASHERS PER 210.8(D) AND
STYLE PER BUILDER SPECIFICATIONS 422.5.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


W.P. ALL SERVICES SUPPLYING DWELLING
GFI PENDANT OR CHANDELIER LIGHT FIXTURE UNITS SHALL BE PROVIDED WITH A SURGE-PROTECTION
- STYLE PER BUILDER SPECIFICATIONS DEVICE (SPD) PER 230.67. THE SPD SHALL BE TYPE I OR II.
PC
S PULL-CHAIN CEILING LIGHT FIXTURE GFCI FOR PERSONNEL SHALL BE PROVIDED AS REQUIRED, PER
GFI
210.8(A) THROUGH (F). THE GFCI SHALL BE INSTALLED IN A

4'-0 1/2"
READILY ACCESSIBLE LOCATION.
LED PUCK CEILING LIGHT FIXTURE
:
RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE

PHONE: 303-770-8300
GFI FOR WP
LED PUCK CEILING LIGHT FIXTURE - WATER PROOF WITH 210.52 (C)(2)(A) AND (C)(2)(B). AT LEAST ONE RECEPTACLE
GFI DW BELOW OUTLET SHALL BE PROVIDED FOR THE FIRST 9 SQ. FT. OF THE
CL GFI COUNTERTOP OR WORK SURFACE AND WITHIN THE LOCATION
LED PUCK MINI CEILING LIGHT FIXTURE PER 210.52 (C)(3).
CL
ALL 125-VOLT THROUGH 250-VOLT, RECEPTACLES INSTALLED IN
GFI THE LOCATIONS SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND
LED PUCK DIRECTIONAL CEILING LIGHT FIXTURE
SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150
MICRO VOLTS OR LESS TO GROUND SHALL HAVE GFCI PROTECTION

S
220v WALL MOUNT SCONCE LIGHT FIXTURE FOR PERSONNEL. INCLUDES BATHROOMS,

5'-0"
- STYLE PER BUILDER SPECIFICATIONS GARAGES, OUTDOORS, CRAWL SPACES, BASEMENTS,
OPT. PENDANTS
KITCHENS, SINKS, BOATHOUSES, BATHTUBS OR SHOWER
KEYLESS WALL MOUNT LIGHT FIXTURE
STALLS - WITHIN 6 FEET OF THE OUTSIDE EDGE OF BATHTUBS
PRE - WIRE - COACH, LANTERN, CARRIAGE, ETC...
OR SHOWER STALLS, LAUNDRY AREAS AND INDOOR DAMP AND
- STYLE PER BUILDER SPECIFICATIONS
OPT.CEILING WET LOCATIONS PER 210.8 (A).
FAN GFI WALL MOUNT VANITY LIGHT FIXTURE
CL - LIGHT BAR - AFCI SHALL BE PROVIDED AS REQUIRED, PER 210.12(A)(B)
- STYLE AND FIXTURE SIZE / BULB COUNT PER (C) AND (D). THE AFCI SHALL BE INSTALLED IN A READILY
BUILDER SPECIFICATIONS ACCESSIBLE LOCATION.
GFI GFI ALL 120-VOLT, SINGLE-PHASE, 15-AMPERE AND 20-AMPERE
BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES
5-LIGHT WALL MOUNT VANITY LIGHT FIXTURE INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS,

6'-0 1/2"
- LIGHT BAR - DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
- STYLE PER BUILDER SPECIFICATIONS BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS OR AREAS
SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN
DB DOOR BELL - PUSH BUTTON 210.12(A)(1) THROUGH (6), (B)(C)(D).

GFI

GFI
GFI +48" AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE
GD GARAGE DOOR OPENER - PUSH BUTTON INSTALLED IN BATHROOMS WITHIN 3'-0" OF THE OUTSIDE EDGE
GFI
OF EACH BASIN. THE RECEPTACLE OUTLET SHALL BE LOCATED
SS S SS S B CHIME - BELL LED
LED LIGHT - ON A WALL OR PARTITION THAT IS ADJACENT TO THE BASIN OR
SIZE PER PLAN BASIN COUNTERTOP, LOCATED ON THE COUNTERTOP, OR
LIGHT
T THERMOSTAT & BLDR. SPEC'S. INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET. IN

S3
NO CASE SHALL THE RECEPTACLE BE LOCATED MORE THAN 12"
CEILING FAN BELOW THE TOP OF THE BASIN OR COUNTERTOP. RECEPTACLE
GFI

- INSTALL LIGHT KIT IF NOTED OUTLET ASSEMBLIES LISTED FOR USE IN COUNTERTOPS SHALL
GFI - PER BUILDER SPECIFICATIONS BE PERMITTED TO BE INSTALLED IN THE COUNTERTOP, PER
210.52(D).
CEILING FAN - (SYMBOL DASHED) TYPICAL OUTLETS TO BE INSTALLED AT +12" A.F.F. U.N.O. -
RE: ROUGH-IN FOR OPTIONAL OUTLETS LOCATED AT +36" H. COUNTERTOPS TO BE INSTALLED
TO LIGHT &
FAN AND LIGHT COMBINATION AT +48" A.F.F. U.N.O. - OUTLETS LOCATED AT +30" H.
SWITCH ABV.

S3
S
COUNTERTOPS TO BE INSTALLED AT +42" A.F.F. U.N.O. -
S BREAKER PANEL - BUILDER LOCATE PER SITE OUTLETS INDICATED AT ENTERTAINMENT / AUDIO CENTERS
T THERM. SPECIFIC CONDITIONS ARE TO BE COORDINATED W/ MILLWORK SUBCONTRACTOR &
GD AUDIO VISUAL CONSULTANT.
B CHIME
IN DWELLING UNITS, LIGHTING OUTLETS SHALL BE INSTALLED
KEYLESS

S3
WHERE SPECIFIED IN 210.70(A)(B) AND (C).
:
RECESSED LIGHT FIXTURES, AND OTHER
ALL LIGHTING REQUIREMENTS SHALL BE IN COMPLIANCE WITH
SIMILAR FIXTURES, INSTALLED IN THE BUILDING THERMAL
TO LIGHT & ARTICLE 410.
ENVELOPE SHALL BE AIR TIGHT, "IC" RATED, AND SEALED TO
: ARE TO BE INSTALLED IN ACCORDANCE WITH
SWITCH BLW. THE DRYWALL, PER TABLE N1102.4.1.1.
MANUFACTURER'S INSTRUCTIONS AND PER ARTICLE 760.
DWELLING UNITS, PROVIDE ALARMS IN THE FOLLOWING LOCATIONS:
INCLUDING ATTACHED AND DETACHED GARAGES AND 1. IN EACH SLEEPING ROOM.

S3
ACCESSORY BUILDINGS SHALL BE LISTED TAMPER

S
2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
GFI -RESISTANT RECEPTABLES PER 406.12. VICINITY OF THE BEDROOMS.
CLG. OUTLET FOR
SHALL BE INSTALLED IN A 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
GARAGE DOOR BASEMENTS/HABITABLE ATTICS, NOT INCLUDING CRAWL
READILY ACCESSIBLE OUTDOOR LOCATION. SERVICE

SS
DISCONNECTS MUST BE MARKED PER 230.85 SPACES AND UNINHABITABLE ATTICS. IN DWELLING UNITS WITH
SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN
THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE
GFI THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL, UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER
X COMMUNICATION BOXES, AND ALL OTHER SIMILAR FIXTURES, LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE
OR AIR-SEALED BOXES SHALL BE INSTALLED, PER TABLE FULL STORY BELOW THE UPPER LEVEL.
N1102.4.1.1. 4. NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR
MECHANICAL VENTILATION SYSTEMS ARE TO BE OPENING OF A BATHROOM WITH A BATHTUB OR SHOWER.
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S 5. INSTALLATION HORIZONTALLY FROM PERMANENTLY
INSTRUCTIONS, THE 2020 NEC AND THE 2018 IRC R303.4 AND INSTALLED COOKING APPLIANCES:
R303.5. - NOT LESS THAN 20' FOR IONIZATION SMOKE ALARMS.

S
P.C. IN - NOT LESS THAN 10' FOR IONIZATION SMOKE ALARMS
SHALL DISCHARGE TO THE OUTDOORS WITH AN ALARM-SILENCING SWITCH.
S S3 THROUGH A SINGLE WALL DUCT. THE DUCT SERVING THE - NOT LESS THAN 6' FOR PHOTOELECTRIC SMOKE ALARMS.
ATTIC HOOD SHALL HAVE A SMOOTH INTERIOR, BE AIR TIGHT, BE : ARE TO BE INSTALLED IN
EQUIPTED WITH A BACK DRAFT DAMPER AND BE INDEPENDENT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
DB OF ALL OTHER EXHAUST SYSTEMS. DUCTS SHALL NOT PER ARTICLE 760. PROVIDE CARBON MONOXIDE ALARMS IN THE
TERMINATE IN ATTICS, CRAWL SPACES OR AREAS INSIDE THE FOLLOWING LOCATIONS:
W.P. BUILDING, PER M1503.1. - ON THE CEILING OR WALL WITHIN 15'-0" OF THE ENTRANCE
GFI TO EACH SEPARATE SLEEPING AREA.
KITCHEN EXHAUST RATES SHALL COMPLY WITH M1503.5. - IN THE BEDROOM WHERE A FUEL-BURNING APPLIANCE IS
LOCATED OR ITS ATTACHED BATHROOM.
MAKEUP AIR IS REQUIRED TO AN EXHAUST HOOD SYSTEM - ON EVERY FLOOR LEVEL.
CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM AND SHALL IN ADDITION, A CARBON MONOXIDE DETECTOR CAN BE
BE MECHANICALLY OR NATURALLY PROVIDED WITH A MAKEUP INSTALLED WITHIN 25'-0" OF ANY FUEL-FIRED HEATER, BOILER,
AIR RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. FIREPLACE OR ATTACHED GARAGE AS LONG AS THERE IS A
PROVIDE NOT LESS THAN ONE GRAVITY OR ELECTRICALLY CENTRALIZED ALARM SYSTEM OR OTHER MECHANISM FOR A
OPERATED DAMPER, PER M1503.6. RESPONSIBLE PERSON TO HEAR THE ALARM AT ALL TIMES.
: COMBINATION SMOKE AND CARBON
DOMESTIC OPEN-TOP BROILER MONOXIDE ALARMS SHALL BE PERMITTED TO USE IN PLACE OF
UNITS SHALL HAVE A METAL EXHAUST HOOD AND DISCHARGE SMOKE ALARMS OR CARBON MONOXIDE ALARMS.
TO THE OUTDOORS EQUIPPED WITH A BACK DRAFT DAMPER
OR OTHER MEANS TO CONTROL INFILTRATION/EXFILTRATION PER COLORADO'S HOUSE BILL 1149 ENACTED INTO LAW,
WHEN NOT IN OPERATION. BOILER UNITS INCORPORATING AN REQUIRES THE BUILDER THE OPTION OF HAVING THE HOME
INTEGRAL EXHAUST SYSTEM, DOES NOT REQUIRE AN INCLUDE OR BE PRE-WIRED FOR SOLAR PHOTOVOLTAIC
EXHAUST HOOD, PER M1503.1. INSTALLATION. ALSO PROVIDED TO THE HOMEOWNERS PER
THE REQUIREMENTS OF THE LAW IS A LIST OF LOCAL SOLAR
: INSTALLERS/CONTRACTORS WHO CAN ASSESS THE HOME'S
SHALL BE DESIGNED IN ACCORDANCE WITH SECTIONS M1505.4. SOLAR ENERGY POTENTIAL.
BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY PROVIDE FULL LENGTH CONDUIT TUBE FROM BASEMENT TO
ROOMS AND SIMILAR ROOMS SHALL BE PROVIDED WITH ATTIC, PRE-WIRE FOR SOLAR PHOTOVOLTAIC (PV) SYSTEM
NATURAL VENTILATION W/ AN AREA NOT LESS THAN 1 1/2 SF - INSTALLATION. COORDINATED PER BUILDER.
IN BATHROOMS, LAUNDRY ROOMS AND SIMILAR ROOMS, THE SOLAR (PV) SYSTEM TO BE INSTALLED IN ACCORDANCE
WITHOUT NATURAL VENTILATION, A MECHANICAL VENTILATION WITH MANUFACTURER'S INSTRUCTIONS AND SHALL COMPLY
SYSTEM CONNECTED DIRECTLY TO EXTERIOR CAPABLE OF WITH ARTICLE 690
VENTILATION RATES OF 50 CFM INTERMITTENT OR 20 CFM : A MINIMUM OF 90% OF
CONTINUOUS FOR BATHROOMS, TOILET ROOMS SHALL BE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
PROVIDED. A MECHANICAL VENTILATION SYSTEM WITH BE HIGH-EFFICACY LAMPS, PER N1104.1
VENTILATION RATES OF 100 CFM INTERMITTENT OR 25 CFM
CONTINUOUS FOR KITCHENS SHALL BE PROVIDED, PER

MAIN LEVEL ELECTRICAL PLAN M1505.4.

1 SCALE: 1/4" = 1'-0"


: ALL BATH FANS MUST MEET ENERGY STAR V3.2
REQUIREMENTS EFFECTIVE JAN 2021

©
ELECTRICAL SYMBOLS ELECTRICAL NOTES

STANDARD DUPLEX OUTLET 2020 NATIONAL ELECTRICAL CODE (NEC)


AND COMPLIANCE WITH THE 2018 IRC
GFI DUPLEX OUTLET
- GROUND FAULT CIRCUIT INTERUPTER REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION
WP NOT SHOWN OR NOTED ON PLANS.
DUPLEX OUTLET - GFI & WEATHER PROOF
GFI
ALL ELECTRICAL OUTLETS, LIGHT FIXTURES, FANS, SWITCHES,
SWITCHED DUPLEX OUTLET ETC..., SHALL COMPLY W/ 2020 NEC. Godden|Sudik
DWELLING UNIT RECEPTACLE OUTLETS ARE SHOWN FOR
FLOOR OUTLET
REPRESENTATION PURPOSES ONLY, ACTUAL LOCATIONS TO
A R C H I T E C T S
220 VOLT OUTLET COMPLY, PER 210.52 THROUGH 210.65 SEE WHAT COULD BE
BUILDER TO COORDINATE LOCATION OF GAS, WATER &
DUPLEX OUTLET IN CEILING
ELECTRICAL METER & PANEL LOCATIONS.
DIRECT WIRE VERIFY POWER REQUIREMENTS W/ APPLIANCE/
EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
EXHAUST FAN &
EXHAUST FAN
LIGHT COMBINATION
IN EVERY KITCHEN, FAMILY RM., DINING RM., LIVING RM.,
TV CABLE TELEVISION OUTLET PARLOR, LIBRARY, DEN, SUN RM., BDRM., REC. RM., OR SIMILAR
- BUILDER TO VERIFY LOCATION ROOM OR AREA OF DWELLING UNITS, RECEPTACLE OUTLETS
W.P.
TV - HIGH & LOW OUTLET & "SMURF TUBE" CONNECTOR SHALL BE INSTALLED AS SPECIFIED IN 210.52
GFI (A)(1) THROUGH (A)(4).
OR SIMILAR STACKED @ 12" A.F.F. & 50" A.F.F. -
INTEGRATED COMMUNICATION PORT RECEPTACLES SHALL BE INSTALLED SO THAT NO
S (CABLE/DATA/PHONE) @ 12" A.F.F. POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF
- BUILDER TO VERIFY SPEC'S. & LOCATION ANY WALL SPACE IS MORE THAN 6'-0" FROM A RECEPTACLE
OUTLET, THAT DO NOT HAVE COUNTERTOPS OR SIMILAR WORK
INTEGRATED COMMUNICATION JACK SPACES, PER 210.52(A)(1)(2).
- INCLUDES (2) PHONE & (2) CABLE OUTLETS RECEPTACLE OUTLETS IN FLOORS
- BUILDER TO VERIFY SPEC'S. & LOCATION SHALL NOT BE COUNTED AS PART OF THE REQUIRED NUMBER
TELEPHONE JACK OF RECEPTACLE OUTLETS EXCEPT WHERE LOCATED WITHIN
- BUILDER TO VERIFY LOCATION 18" OF THE WALL, PER 210.52(A)(3).
OUTLETS IN FLOORS, TEL. JACKS AND TELEVISION LOCATIONS
TELEPHONE JACK PRE-WIRE TO BE FIELD VERIFIED BY BUILDER.
REFER TO STANDARD - BUILDER TO VERIFY LOCATION
IN THE KITCHEN, PANTRY, BREAKFAST AREA, DINING ROOM OR
ELECTRICAL PLAN FOR SIMILAR AREA OF A DWELLING UNIT, TWO OR MORE 20-AMPERE
MORE INFORMATION ICC-ES SMOKE DETECTOR
D SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY
- LINK AUDIO TO OTHER UNITS
LED PUCK LIGHT 210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE
CARBON MONOXIDE DETECTOR OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP AND WORK

OPT. PATIO / DECK ELECTRICAL PLAN


C
SURFACE OUTLETS COVERED BY 210.52(C), AND RECEPTACLE
X CARBON MONOXIDE & SMOKE DETECTOR COMBINATION OUTLETS FOR REFRIGERATION EQUIPTMENT, PER 210.52(B)(1).

1 SCALE: 1/4" = 1'-0" J JUNCTION BOX


AT LEAST ONE ADDITIONAL 20-AMPERE BRANCH CIRCUIT SHALL
BE PROVIDED TO SUPPLY THE LAUNDRY RECEPTACLE
OUTLET(S) REQUIRED BY 210.52(F), PER 210.11(C)(2).
S SINGLE SWITCH
ONE OR MORE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL

S
S3 3-WAY SWITCH BE PROVIDED TO SUPPLY A BATHROOM(S) RECEPTACLE
USB OUTLET OUTLET(S). REQUIRED BY 210.52 (D) AND ANY COUNTERTOP
S4 4-WAY SWITCH AND SIMILAR WORK SURFACE RECEPTACLE OUTLETS PER
2-WAY SWITCH 210.11(C)(3).
SD DIMMER SWITCH
CL GFCI PROTECTION SHALL BE PROVIDED FOR OUTLETS THAT
SURFACED MOUNTED CEILING LIGHT FIXTURE - SUPPLY SUMP PUMPS AND DISHWASHERS PER 210.8(D) AND
TV - HIGH & LOW OUTLET STYLE PER BUILDER SPECIFICATIONS 422.5.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


& "SMURF TUBE" CONNECTOR
3'-2"

ALL SERVICES SUPPLYING DWELLING


OR SIMILAR STACKED @ PENDANT OR CHANDELIER LIGHT FIXTURE UNITS SHALL BE PROVIDED WITH A SURGE-PROTECTION
12" A.F.F. & 50" A.F.F. - STYLE PER BUILDER SPECIFICATIONS DEVICE (SPD) PER 230.67. THE SPD SHALL BE TYPE I OR II.
PC
PULL-CHAIN CEILING LIGHT FIXTURE GFCI FOR PERSONNEL SHALL BE PROVIDED AS REQUIRED, PER
DUAL DATA, 210.8(A) THROUGH (F). THE GFCI SHALL BE INSTALLED IN A
2 CAT6 WP WP WP WP READILY ACCESSIBLE LOCATION.
LED PUCK CEILING LIGHT FIXTURE
OUTLET BLW. :
OUTLET
RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE

PHONE: 303-770-8300
COUNTER WP
LED PUCK CEILING LIGHT FIXTURE - WATER PROOF WITH 210.52 (C)(2)(A) AND (C)(2)(B). AT LEAST ONE RECEPTACLE
USB OUTLET USB OUTLET OUTLET SHALL BE PROVIDED FOR THE FIRST 9 SQ. FT. OF THE
ABV. COUNTER ABV. COUNTER COUNTERTOP OR WORK SURFACE AND WITHIN THE LOCATION
LED PUCK MINI CEILING LIGHT FIXTURE PER 210.52 (C)(3).
ALL 125-VOLT THROUGH 250-VOLT, RECEPTACLES INSTALLED IN
LED PUCK DIRECTIONAL CEILING LIGHT FIXTURE THE LOCATIONS SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND
S
W.P. SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150
GFI VOLTS OR LESS TO GROUND SHALL HAVE GFCI PROTECTION
WALL MOUNT SCONCE LIGHT FIXTURE FOR PERSONNEL. INCLUDES BATHROOMS,
- STYLE PER BUILDER SPECIFICATIONS GARAGES, OUTDOORS, CRAWL SPACES, BASEMENTS,
S
KITCHENS, SINKS, BOATHOUSES, BATHTUBS OR SHOWER
DUAL DATA, WALL MOUNT LIGHT FIXTURE
STALLS - WITHIN 6 FEET OF THE OUTSIDE EDGE OF BATHTUBS
2 CAT6 REFER TO STANDARD - COACH, LANTERN, CARRIAGE, ETC...
OR SHOWER STALLS, LAUNDRY AREAS AND INDOOR DAMP AND
ELECTRICAL PLAN FOR - STYLE PER BUILDER SPECIFICATIONS
WET LOCATIONS PER 210.8 (A).
MORE INFORMATION WALL MOUNT VANITY LIGHT FIXTURE
- LIGHT BAR - AFCI SHALL BE PROVIDED AS REQUIRED, PER 210.12(A)(B)
- STYLE AND FIXTURE SIZE / BULB COUNT PER (C) AND (D). THE AFCI SHALL BE INSTALLED IN A READILY
BUILDER SPECIFICATIONS ACCESSIBLE LOCATION.

OPT. SINGLE HOME REFER TO STANDARD 5-LIGHT WALL MOUNT VANITY LIGHT FIXTURE
ALL 120-VOLT, SINGLE-PHASE, 15-AMPERE AND 20-AMPERE
BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES
INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS,

OPT. FIREPLACE OPT. EXT. COVERED PATIO / DECK


ELECTRICAL PLAN FOR

OFFICE @ STUDY MORE INFORMATION


- LIGHT BAR -
- STYLE PER BUILDER SPECIFICATIONS
DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS OR AREAS
SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN

ELECTRICAL PLAN ELECTRICAL PLAN ELECTRICAL PLAN DB DOOR BELL - PUSH BUTTON 210.12(A)(1) THROUGH (6), (B)(C)(D).
AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE

7 ALL ELEVATIONS SIMILAR SCALE: 1/4" = 1'-0" 5 OPT. 36" FIREPLACE SHOWN AT GREAT ROOM SCALE: 1/4" = 1'-0" 2 SCALE: 1/4" = 1'-0"
B
GD GARAGE DOOR OPENER - PUSH BUTTON

CHIME - BELL LED


LED LIGHT -
INSTALLED IN BATHROOMS WITHIN 3'-0" OF THE OUTSIDE EDGE
OF EACH BASIN. THE RECEPTACLE OUTLET SHALL BE LOCATED
ON A WALL OR PARTITION THAT IS ADJACENT TO THE BASIN OR
SIZE PER PLAN BASIN COUNTERTOP, LOCATED ON THE COUNTERTOP, OR
LIGHT
T THERMOSTAT & BLDR. SPEC'S. INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET. IN
NO CASE SHALL THE RECEPTACLE BE LOCATED MORE THAN 12"
CEILING FAN BELOW THE TOP OF THE BASIN OR COUNTERTOP. RECEPTACLE
- INSTALL LIGHT KIT IF NOTED OUTLET ASSEMBLIES LISTED FOR USE IN COUNTERTOPS SHALL
- PER BUILDER SPECIFICATIONS BE PERMITTED TO BE INSTALLED IN THE COUNTERTOP, PER
210.52(D).
CEILING FAN - (SYMBOL DASHED) TYPICAL OUTLETS TO BE INSTALLED AT +12" A.F.F. U.N.O. -
RE: ROUGH-IN FOR OPTIONAL OUTLETS LOCATED AT +36" H. COUNTERTOPS TO BE INSTALLED
FAN AND LIGHT COMBINATION AT +48" A.F.F. U.N.O. - OUTLETS LOCATED AT +30" H.
COUNTERTOPS TO BE INSTALLED AT +42" A.F.F. U.N.O. -
BREAKER PANEL - BUILDER LOCATE PER SITE OUTLETS INDICATED AT ENTERTAINMENT / AUDIO CENTERS
SPECIFIC CONDITIONS ARE TO BE COORDINATED W/ MILLWORK SUBCONTRACTOR &
AUDIO VISUAL CONSULTANT.
IN DWELLING UNITS, LIGHTING OUTLETS SHALL BE INSTALLED
WHERE SPECIFIED IN 210.70(A)(B) AND (C).
:
RECESSED LIGHT FIXTURES, AND OTHER
ALL LIGHTING REQUIREMENTS SHALL BE IN COMPLIANCE WITH
SIMILAR FIXTURES, INSTALLED IN THE BUILDING THERMAL
ARTICLE 410.
ENVELOPE SHALL BE AIR TIGHT, "IC" RATED, AND SEALED TO
THE DRYWALL, PER TABLE N1102.4.1.1. : ARE TO BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS AND PER ARTICLE 760.
DWELLING UNITS, PROVIDE ALARMS IN THE FOLLOWING LOCATIONS:
INCLUDING ATTACHED AND DETACHED GARAGES AND 1. IN EACH SLEEPING ROOM.
ACCESSORY BUILDINGS SHALL BE LISTED TAMPER 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
-RESISTANT RECEPTABLES PER 406.12. VICINITY OF THE BEDROOMS.
SHALL BE INSTALLED IN A 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
READILY ACCESSIBLE OUTDOOR LOCATION. SERVICE BASEMENTS/HABITABLE ATTICS, NOT INCLUDING CRAWL
DISCONNECTS MUST BE MARKED PER 230.85 SPACES AND UNINHABITABLE ATTICS. IN DWELLING UNITS WITH
SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN
S THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE
GFI THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL, UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER
LED PUCK LIGHT COMMUNICATION BOXES, AND ALL OTHER SIMILAR FIXTURES, LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE
OR AIR-SEALED BOXES SHALL BE INSTALLED, PER TABLE FULL STORY BELOW THE UPPER LEVEL.
N1102.4.1.1. 4. NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR
GFI FOR OPENING OF A BATHROOM WITH A BATHTUB OR SHOWER.
GFI MECHANICAL VENTILATION SYSTEMS ARE TO BE
DW BELOW
USB OUTLET GFI INSTALLED IN ACCORDANCE WITH MANUFACTURER'S 5. INSTALLATION HORIZONTALLY FROM PERMANENTLY

SS
INSTRUCTIONS, THE 2020 NEC AND THE 2018 IRC R303.4 AND INSTALLED COOKING APPLIANCES:
DUAL DATA, - NOT LESS THAN 20' FOR IONIZATION SMOKE ALARMS.
DUAL DATA, R303.5.
2 CAT6 GFI - NOT LESS THAN 10' FOR IONIZATION SMOKE ALARMS
2 CAT6
SHALL DISCHARGE TO THE OUTDOORS WITH AN ALARM-SILENCING SWITCH.
S

HOOD - NOT LESS THAN 6' FOR PHOTOELECTRIC SMOKE ALARMS.

GFI
THROUGH A SINGLE WALL DUCT. THE DUCT SERVING THE
S

2-WAY SWITCH 220v HOOD SHALL HAVE A SMOOTH INTERIOR, BE AIR TIGHT, BE : ARE TO BE INSTALLED IN
OPT. PENDANTS EQUIPTED WITH A BACK DRAFT DAMPER AND BE INDEPENDENT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
OF ALL OTHER EXHAUST SYSTEMS. DUCTS SHALL NOT PER ARTICLE 760. PROVIDE CARBON MONOXIDE ALARMS IN THE
CL
S TERMINATE IN ATTICS, CRAWL SPACES OR AREAS INSIDE THE FOLLOWING LOCATIONS:
TO OPT.
BUILDING, PER M1503.1. - ON THE CEILING OR WALL WITHIN 15'-0" OF THE ENTRANCE
TV - HIGH & LOW OUTLET GFI OVEN BLW.
TO EACH SEPARATE SLEEPING AREA.
3'-2"

& "SMURF TUBE" CONNECTOR D


KITCHEN EXHAUST RATES SHALL COMPLY WITH M1503.5. - IN THE BEDROOM WHERE A FUEL-BURNING APPLIANCE IS
OR SIMILAR STACKED @ LOCATED OR ITS ATTACHED BATHROOM.
12" A.F.F. & 50" A.F.F. GFI MAKEUP AIR IS REQUIRED TO AN EXHAUST HOOD SYSTEM - ON EVERY FLOOR LEVEL.
GFI CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM AND SHALL IN ADDITION, A CARBON MONOXIDE DETECTOR CAN BE
P.C. IN
BE MECHANICALLY OR NATURALLY PROVIDED WITH A MAKEUP INSTALLED WITHIN 25'-0" OF ANY FUEL-FIRED HEATER, BOILER,
AIR RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. FIREPLACE OR ATTACHED GARAGE AS LONG AS THERE IS A
OUTLET BLW. OUTLET USB OUTLET ATTIC PROVIDE NOT LESS THAN ONE GRAVITY OR ELECTRICALLY CENTRALIZED ALARM SYSTEM OR OTHER MECHANISM FOR A
COUNTER ABV. COUNTER OPERATED DAMPER, PER M1503.6. RESPONSIBLE PERSON TO HEAR THE ALARM AT ALL TIMES.
: COMBINATION SMOKE AND CARBON
220v

USB OUTLET DUAL DATA,


GFI

+48" DOMESTIC OPEN-TOP BROILER MONOXIDE ALARMS SHALL BE PERMITTED TO USE IN PLACE OF
ABV. COUNTER 2 CAT6 UNITS SHALL HAVE A METAL EXHAUST HOOD AND DISCHARGE
GFI SMOKE ALARMS OR CARBON MONOXIDE ALARMS.
TO THE OUTDOORS EQUIPPED WITH A BACK DRAFT DAMPER
DUAL DATA, OUTLET BLW. SS S
OR OTHER MEANS TO CONTROL INFILTRATION/EXFILTRATION PER COLORADO'S HOUSE BILL 1149 ENACTED INTO LAW,
2 CAT6 COUNTER WHEN NOT IN OPERATION. BOILER UNITS INCORPORATING AN REQUIRES THE BUILDER THE OPTION OF HAVING THE HOME
INTEGRAL EXHAUST SYSTEM, DOES NOT REQUIRE AN INCLUDE OR BE PRE-WIRED FOR SOLAR PHOTOVOLTAIC
S EXHAUST HOOD, PER M1503.1. INSTALLATION. ALSO PROVIDED TO THE HOMEOWNERS PER
GFI THE REQUIREMENTS OF THE LAW IS A LIST OF LOCAL SOLAR
: INSTALLERS/CONTRACTORS WHO CAN ASSESS THE HOME'S
SHALL BE DESIGNED IN ACCORDANCE WITH SECTIONS M1505.4. SOLAR ENERGY POTENTIAL.
OUTLET ABV. BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY PROVIDE FULL LENGTH CONDUIT TUBE FROM BASEMENT TO
COUNTER ROOMS AND SIMILAR ROOMS SHALL BE PROVIDED WITH ATTIC, PRE-WIRE FOR SOLAR PHOTOVOLTAIC (PV) SYSTEM
REFER TO STANDARD INSTALLATION. COORDINATED PER BUILDER.
NATURAL VENTILATION W/ AN AREA NOT LESS THAN 1 1/2 SF -
ELECTRICAL PLAN FOR THE SOLAR (PV) SYSTEM TO BE INSTALLED IN ACCORDANCE
IN BATHROOMS, LAUNDRY ROOMS AND SIMILAR ROOMS,
MORE INFORMATION WITH MANUFACTURER'S INSTRUCTIONS AND SHALL COMPLY
WITHOUT NATURAL VENTILATION, A MECHANICAL VENTILATION
SYSTEM CONNECTED DIRECTLY TO EXTERIOR CAPABLE OF WITH ARTICLE 690
REFER TO STANDARD
REFER TO STANDARD VENTILATION RATES OF 50 CFM INTERMITTENT OR 20 CFM : A MINIMUM OF 90% OF
ELECTRICAL PLAN FOR
ELECTRICAL PLAN FOR

OPT. DOUBLE HOME


CONTINUOUS FOR BATHROOMS, TOILET ROOMS SHALL BE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
MORE INFORMATION
MORE INFORMATION PROVIDED. A MECHANICAL VENTILATION SYSTEM WITH BE HIGH-EFFICACY LAMPS, PER N1104.1
VENTILATION RATES OF 100 CFM INTERMITTENT OR 25 CFM
CONTINUOUS FOR KITCHENS SHALL BE PROVIDED, PER

OFFICE @ STUDY OPT. LINEAR FIREPLACE OPT. CHEF'S KITCHEN OPT. BEDROOM 5 M1505.4.

ELECTRICAL PLAN ELECTRICAL PLAN ELECTRICAL PLAN ELECTRICAL PLAN


8 ALL ELEVATIONS SIMILAR SCALE: 1/4" = 1'-0" 6 OPT. 42" FIREPLACE SHOWN AT GREAT ROOM SCALE: 1/4" = 1'-0" 4 ALL ELEVATIONS SIMILAR SCALE: 1/4" = 1'-0" 3 SCALE: 1/4" = 1'-0"
: ALL BATH FANS MUST MEET ENERGY STAR V3.2
REQUIREMENTS EFFECTIVE JAN 2021

©
ELECTRICAL SYMBOLS ELECTRICAL NOTES

STANDARD DUPLEX OUTLET 2020 NATIONAL ELECTRICAL CODE (NEC)


AND COMPLIANCE WITH THE 2018 IRC
GFI DUPLEX OUTLET
- GROUND FAULT CIRCUIT INTERUPTER REFER TO GENERAL NOTES FOR ADDITIONAL INFORMATION
WP NOT SHOWN OR NOTED ON PLANS.
DUPLEX OUTLET - GFI & WEATHER PROOF
GFI
ALL ELECTRICAL OUTLETS, LIGHT FIXTURES, FANS, SWITCHES,
SWITCHED DUPLEX OUTLET ETC..., SHALL COMPLY W/ 2020 NEC. Godden|Sudik
DWELLING UNIT RECEPTACLE OUTLETS ARE SHOWN FOR
FLOOR OUTLET
REPRESENTATION PURPOSES ONLY, ACTUAL LOCATIONS TO
A R C H I T E C T S
220 VOLT OUTLET COMPLY, PER 210.52 THROUGH 210.65 SEE WHAT COULD BE
BUILDER TO COORDINATE LOCATION OF GAS, WATER &
DUPLEX OUTLET IN CEILING
ELECTRICAL METER & PANEL LOCATIONS.
DIRECT WIRE VERIFY POWER REQUIREMENTS W/ APPLIANCE/
EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
EXHAUST FAN &
EXHAUST FAN
LIGHT COMBINATION
IN EVERY KITCHEN, FAMILY RM., DINING RM., LIVING RM.,
TV CABLE TELEVISION OUTLET PARLOR, LIBRARY, DEN, SUN RM., BDRM., REC. RM., OR SIMILAR
- BUILDER TO VERIFY LOCATION ROOM OR AREA OF DWELLING UNITS, RECEPTACLE OUTLETS
TV - HIGH & LOW OUTLET & "SMURF TUBE" CONNECTOR SHALL BE INSTALLED AS SPECIFIED IN 210.52
OR SIMILAR STACKED @ 12" A.F.F. & 50" A.F.F. - (A)(1) THROUGH (A)(4).
INTEGRATED COMMUNICATION PORT RECEPTACLES SHALL BE INSTALLED SO THAT NO
(CABLE/DATA/PHONE) @ 12" A.F.F. POINT MEASURED HORIZONTALLY ALONG THE FLOOR LINE OF
- BUILDER TO VERIFY SPEC'S. & LOCATION ANY WALL SPACE IS MORE THAN 6'-0" FROM A RECEPTACLE
OUTLET, THAT DO NOT HAVE COUNTERTOPS OR SIMILAR WORK
INTEGRATED COMMUNICATION JACK SPACES, PER 210.52(A)(1)(2).
- INCLUDES (2) PHONE & (2) CABLE OUTLETS RECEPTACLE OUTLETS IN FLOORS
- BUILDER TO VERIFY SPEC'S. & LOCATION SHALL NOT BE COUNTED AS PART OF THE REQUIRED NUMBER
TELEPHONE JACK OF RECEPTACLE OUTLETS EXCEPT WHERE LOCATED WITHIN
- BUILDER TO VERIFY LOCATION 18" OF THE WALL, PER 210.52(A)(3).
OUTLETS IN FLOORS, TEL. JACKS AND TELEVISION LOCATIONS
TELEPHONE JACK PRE-WIRE TO BE FIELD VERIFIED BY BUILDER.
- BUILDER TO VERIFY LOCATION
IN THE KITCHEN, PANTRY, BREAKFAST AREA, DINING ROOM OR
ICC-ES SMOKE DETECTOR SIMILAR AREA OF A DWELLING UNIT, TWO OR MORE 20-AMPERE
D SMALL-APPLIANCE BRANCH CIRCUITS REQUIRED BY
- LINK AUDIO TO OTHER UNITS
210.11(C)(1) SHALL SERVE ALL WALL AND FLOOR RECEPTACLE
C CARBON MONOXIDE DETECTOR OUTLETS COVERED BY 210.52(A), ALL COUNTERTOP AND WORK
SURFACE OUTLETS COVERED BY 210.52(C), AND RECEPTACLE
X CARBON MONOXIDE & SMOKE DETECTOR COMBINATION OUTLETS FOR REFRIGERATION EQUIPTMENT, PER 210.52(B)(1).
AT LEAST ONE ADDITIONAL 20-AMPERE BRANCH CIRCUIT SHALL
J JUNCTION BOX BE PROVIDED TO SUPPLY THE LAUNDRY RECEPTACLE
WP WP OUTLET(S) REQUIRED BY 210.52(F), PER 210.11(C)(2).
S SINGLE SWITCH
ONE OR MORE 120-VOLT, 20-AMPERE BRANCH CIRCUIT SHALL
S3 3-WAY SWITCH BE PROVIDED TO SUPPLY A BATHROOM(S) RECEPTACLE
OUTLET(S). REQUIRED BY 210.52 (D) AND ANY COUNTERTOP
S4 4-WAY SWITCH AND SIMILAR WORK SURFACE RECEPTACLE OUTLETS PER
SD DIMMER SWITCH 210.11(C)(3).

SS
PRE - WIRE GFCI PROTECTION SHALL BE PROVIDED FOR OUTLETS THAT
OPT.CEILING SURFACED MOUNTED CEILING LIGHT FIXTURE - SUPPLY SUMP PUMPS AND DISHWASHERS PER 210.8(D) AND
FAN STYLE PER BUILDER SPECIFICATIONS 422.5.

8390 E. Crescent Parkway, Suite 650 Greenwood Village, CO 80111


ALL SERVICES SUPPLYING DWELLING
SS PENDANT OR CHANDELIER LIGHT FIXTURE UNITS SHALL BE PROVIDED WITH A SURGE-PROTECTION
- STYLE PER BUILDER SPECIFICATIONS DEVICE (SPD) PER 230.67. THE SPD SHALL BE TYPE I OR II.

GFI
PC
PULL-CHAIN CEILING LIGHT FIXTURE GFCI FOR PERSONNEL SHALL BE PROVIDED AS REQUIRED, PER
210.8(A) THROUGH (F). THE GFCI SHALL BE INSTALLED IN A
READILY ACCESSIBLE LOCATION.

SSS
LED PUCK CEILING LIGHT FIXTURE
GFI :
RECEPTACLE OUTLETS SHALL BE INSTALLED IN ACCORDANCE

GFI

PHONE: 303-770-8300
WP
LED PUCK CEILING LIGHT FIXTURE - WATER PROOF WITH 210.52 (C)(2)(A) AND (C)(2)(B). AT LEAST ONE RECEPTACLE
OUTLET SHALL BE PROVIDED FOR THE FIRST 9 SQ. FT. OF THE
COUNTERTOP OR WORK SURFACE AND WITHIN THE LOCATION
LED PUCK MINI CEILING LIGHT FIXTURE PER 210.52 (C)(3).

GFI
ALL 125-VOLT THROUGH 250-VOLT, RECEPTACLES INSTALLED IN
S THE LOCATIONS SPECIFIED IN 210.8(A)(1) THROUGH (A)(11) AND
LED PUCK DIRECTIONAL CEILING LIGHT FIXTURE
SUPPLIED BY SINGLE-PHASE BRANCH CIRCUITS RATED 150
VOLTS OR LESS TO GROUND SHALL HAVE GFCI PROTECTION

S
WALL MOUNT SCONCE LIGHT FIXTURE FOR PERSONNEL. INCLUDES BATHROOMS,
- STYLE PER BUILDER SPECIFICATIONS

S
GARAGES, OUTDOORS, CRAWL SPACES, BASEMENTS,
P.C. IN KITCHENS, SINKS, BOATHOUSES, BATHTUBS OR SHOWER
D WALL MOUNT LIGHT FIXTURE
STALLS - WITHIN 6 FEET OF THE OUTSIDE EDGE OF BATHTUBS
D - COACH, LANTERN, CARRIAGE, ETC...
OR SHOWER STALLS, LAUNDRY AREAS AND INDOOR DAMP AND
ATTIC - STYLE PER BUILDER SPECIFICATIONS
WET LOCATIONS PER 210.8 (A).

S3
SSS
WALL MOUNT VANITY LIGHT FIXTURE
- LIGHT BAR - AFCI SHALL BE PROVIDED AS REQUIRED, PER 210.12(A)(B)
- STYLE AND FIXTURE SIZE / BULB COUNT PER (C) AND (D). THE AFCI SHALL BE INSTALLED IN A READILY
BUILDER SPECIFICATIONS ACCESSIBLE LOCATION.
ALL 120-VOLT, SINGLE-PHASE, 15-AMPERE AND 20-AMPERE
BRANCH CIRCUITS SUPPLYING OUTLETS OR DEVICES
D X 5-LIGHT WALL MOUNT VANITY LIGHT FIXTURE INSTALLED IN DWELLING UNIT KITCHENS, FAMILY ROOMS,
- LIGHT BAR - DINING ROOMS, LIVING ROOMS, PARLORS, LIBRARIES, DENS,
- STYLE PER BUILDER SPECIFICATIONS BEDROOMS, SUNROOMS, RECREATION ROOMS, CLOSETS,
HALLWAYS, LAUNDRY AREAS, AND SIMILAR ROOMS OR AREAS

S
SHALL BE PROTECTED BY ANY OF THE MEANS DESCRIBED IN
DB DOOR BELL - PUSH BUTTON 210.12(A)(1) THROUGH (6), (B)(C)(D).
S AT LEAST ONE WALL RECEPTACLE OUTLET SHALL BE
GD GARAGE DOOR OPENER - PUSH BUTTON INSTALLED IN BATHROOMS WITHIN 3'-0" OF THE OUTSIDE EDGE
TO SWITCH OF EACH BASIN. THE RECEPTACLE OUTLET SHALL BE LOCATED
D BELOW B CHIME - BELL LED LIGHT - ON A WALL OR PARTITION THAT IS ADJACENT TO THE BASIN OR
LED
SIZE PER PLAN BASIN COUNTERTOP, LOCATED ON THE COUNTERTOP, OR
LIGHT
T THERMOSTAT & BLDR. SPEC'S. INSTALLED ON THE SIDE OR FACE OF THE BASIN CABINET. IN
NO CASE SHALL THE RECEPTACLE BE LOCATED MORE THAN 12"
GFI CEILING FAN BELOW THE TOP OF THE BASIN OR COUNTERTOP. RECEPTACLE

220v
- INSTALL LIGHT KIT IF NOTED OUTLET ASSEMBLIES LISTED FOR USE IN COUNTERTOPS SHALL
- PER BUILDER SPECIFICATIONS BE PERMITTED TO BE INSTALLED IN THE COUNTERTOP, PER
210.52(D).
CEILING FAN - (SYMBOL DASHED) TYPICAL OUTLETS TO BE INSTALLED AT +12" A.F.F. U.N.O. -
RE: ROUGH-IN FOR OPTIONAL OUTLETS LOCATED AT +36" H. COUNTERTOPS TO BE INSTALLED
FAN AND LIGHT COMBINATION AT +48" A.F.F. U.N.O. - OUTLETS LOCATED AT +30" H.

S3S3
COUNTERTOPS TO BE INSTALLED AT +42" A.F.F. U.N.O. -

SS
BREAKER PANEL - BUILDER LOCATE PER SITE OUTLETS INDICATED AT ENTERTAINMENT / AUDIO CENTERS
SPECIFIC CONDITIONS ARE TO BE COORDINATED W/ MILLWORK SUBCONTRACTOR &
AUDIO VISUAL CONSULTANT.
IN DWELLING UNITS, LIGHTING OUTLETS SHALL BE INSTALLED
WHERE SPECIFIED IN 210.70(A)(B) AND (C).
:
RECESSED LIGHT FIXTURES, AND OTHER
ALL LIGHTING REQUIREMENTS SHALL BE IN COMPLIANCE WITH
SIMILAR FIXTURES, INSTALLED IN THE BUILDING THERMAL
ARTICLE 410.
ENVELOPE SHALL BE AIR TIGHT, "IC" RATED, AND SEALED TO
THE DRYWALL, PER TABLE N1102.4.1.1. : ARE TO BE INSTALLED IN ACCORDANCE WITH
MANUFACTURER'S INSTRUCTIONS AND PER ARTICLE 760.
DWELLING UNITS, PROVIDE ALARMS IN THE FOLLOWING LOCATIONS:
INCLUDING ATTACHED AND DETACHED GARAGES AND 1. IN EACH SLEEPING ROOM.
ACCESSORY BUILDINGS SHALL BE LISTED TAMPER 2. OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE
-RESISTANT RECEPTABLES PER 406.12. VICINITY OF THE BEDROOMS.
SHALL BE INSTALLED IN A 3. ON EACH ADDITIONAL STORY OF THE DWELLING, INCLUDING
READILY ACCESSIBLE OUTDOOR LOCATION. SERVICE BASEMENTS/HABITABLE ATTICS, NOT INCLUDING CRAWL
DISCONNECTS MUST BE MARKED PER 230.85 SPACES AND UNINHABITABLE ATTICS. IN DWELLING UNITS WITH
SPLIT LEVELS AND WITHOUT AN INTERVENING DOOR BETWEEN
THE ADJACENT LEVELS, A SMOKE ALARM INSTALLED ON THE
THE AIR BARRIER SHALL BE INSTALLED BEHIND ELECTRICAL, UPPER LEVEL SHALL SUFFICE FOR THE ADJACENT LOWER
COMMUNICATION BOXES, AND ALL OTHER SIMILAR FIXTURES, LEVEL PROVIDED THAT THE LOWER LEVEL IS LESS THAN ONE
OR AIR-SEALED BOXES SHALL BE INSTALLED, PER TABLE FULL STORY BELOW THE UPPER LEVEL.
N1102.4.1.1. 4. NOT LESS THAN 3 FEET HORIZONTALLY FROM THE DOOR OR
MECHANICAL VENTILATION SYSTEMS ARE TO BE OPENING OF A BATHROOM WITH A BATHTUB OR SHOWER.
INSTALLED IN ACCORDANCE WITH MANUFACTURER'S 5. INSTALLATION HORIZONTALLY FROM PERMANENTLY
INSTRUCTIONS, THE 2020 NEC AND THE 2018 IRC R303.4 AND INSTALLED COOKING APPLIANCES:
R303.5. - NOT LESS THAN 20' FOR IONIZATION SMOKE ALARMS.
- NOT LESS THAN 10' FOR IONIZATION SMOKE ALARMS
SHALL DISCHARGE TO THE OUTDOORS WITH AN ALARM-SILENCING SWITCH.
THROUGH A SINGLE WALL DUCT. THE DUCT SERVING THE - NOT LESS THAN 6' FOR PHOTOELECTRIC SMOKE ALARMS.
HOOD SHALL HAVE A SMOOTH INTERIOR, BE AIR TIGHT, BE : ARE TO BE INSTALLED IN
EQUIPTED WITH A BACK DRAFT DAMPER AND BE INDEPENDENT ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS AND
OF ALL OTHER EXHAUST SYSTEMS. DUCTS SHALL NOT PER ARTICLE 760. PROVIDE CARBON MONOXIDE ALARMS IN THE
TERMINATE IN ATTICS, CRAWL SPACES OR AREAS INSIDE THE FOLLOWING LOCATIONS:
BUILDING, PER M1503.1. - ON THE CEILING OR WALL WITHIN 15'-0" OF THE ENTRANCE
TO EACH SEPARATE SLEEPING AREA.
KITCHEN EXHAUST RATES SHALL COMPLY WITH M1503.5. - IN THE BEDROOM WHERE A FUEL-BURNING APPLIANCE IS
LOCATED OR ITS ATTACHED BATHROOM.
MAKEUP AIR IS REQUIRED TO AN EXHAUST HOOD SYSTEM - ON EVERY FLOOR LEVEL.
CAPABLE OF EXHAUSTING IN EXCESS OF 400 CFM AND SHALL IN ADDITION, A CARBON MONOXIDE DETECTOR CAN BE
BE MECHANICALLY OR NATURALLY PROVIDED WITH A MAKEUP INSTALLED WITHIN 25'-0" OF ANY FUEL-FIRED HEATER, BOILER,
AIR RATE APPROXIMATELY EQUAL TO THE EXHAUST AIR RATE. FIREPLACE OR ATTACHED GARAGE AS LONG AS THERE IS A
PROVIDE NOT LESS THAN ONE GRAVITY OR ELECTRICALLY CENTRALIZED ALARM SYSTEM OR OTHER MECHANISM FOR A
OPERATED DAMPER, PER M1503.6. RESPONSIBLE PERSON TO HEAR THE ALARM AT ALL TIMES.
: COMBINATION SMOKE AND CARBON
DOMESTIC OPEN-TOP BROILER MONOXIDE ALARMS SHALL BE PERMITTED TO USE IN PLACE OF
UNITS SHALL HAVE A METAL EXHAUST HOOD AND DISCHARGE SMOKE ALARMS OR CARBON MONOXIDE ALARMS.
TO THE OUTDOORS EQUIPPED WITH A BACK DRAFT DAMPER
OR OTHER MEANS TO CONTROL INFILTRATION/EXFILTRATION PER COLORADO'S HOUSE BILL 1149 ENACTED INTO LAW,
WHEN NOT IN OPERATION. BOILER UNITS INCORPORATING AN REQUIRES THE BUILDER THE OPTION OF HAVING THE HOME
INTEGRAL EXHAUST SYSTEM, DOES NOT REQUIRE AN INCLUDE OR BE PRE-WIRED FOR SOLAR PHOTOVOLTAIC
EXHAUST HOOD, PER M1503.1. INSTALLATION. ALSO PROVIDED TO THE HOMEOWNERS PER
THE REQUIREMENTS OF THE LAW IS A LIST OF LOCAL SOLAR
: INSTALLERS/CONTRACTORS WHO CAN ASSESS THE HOME'S
SHALL BE DESIGNED IN ACCORDANCE WITH SECTIONS M1505.4. SOLAR ENERGY POTENTIAL.
BATHROOMS, WATER CLOSET COMPARTMENTS, LAUNDRY PROVIDE FULL LENGTH CONDUIT TUBE FROM BASEMENT TO
ROOMS AND SIMILAR ROOMS SHALL BE PROVIDED WITH ATTIC, PRE-WIRE FOR SOLAR PHOTOVOLTAIC (PV) SYSTEM
NATURAL VENTILATION W/ AN AREA NOT LESS THAN 1 1/2 SF - INSTALLATION. COORDINATED PER BUILDER.
IN BATHROOMS, LAUNDRY ROOMS AND SIMILAR ROOMS, THE SOLAR (PV) SYSTEM TO BE INSTALLED IN ACCORDANCE
WITHOUT NATURAL VENTILATION, A MECHANICAL VENTILATION WITH MANUFACTURER'S INSTRUCTIONS AND SHALL COMPLY
SYSTEM CONNECTED DIRECTLY TO EXTERIOR CAPABLE OF WITH ARTICLE 690
VENTILATION RATES OF 50 CFM INTERMITTENT OR 20 CFM : A MINIMUM OF 90% OF
CONTINUOUS FOR BATHROOMS, TOILET ROOMS SHALL BE LAMPS IN PERMANENTLY INSTALLED LIGHTING FIXTURES SHALL
PROVIDED. A MECHANICAL VENTILATION SYSTEM WITH BE HIGH-EFFICACY LAMPS, PER N1104.1
VENTILATION RATES OF 100 CFM INTERMITTENT OR 25 CFM
CONTINUOUS FOR KITCHENS SHALL BE PROVIDED, PER

UPPER LEVEL ELECTRICAL PLAN M1505.4.

1 SCALE: 1/4" = 1'-0"


: ALL BATH FANS MUST MEET ENERGY STAR V3.2
REQUIREMENTS EFFECTIVE JAN 2021