PLUMBING SPECIFICATIONS: 3.

00

1.80 0.90
01. ALL SANITARY WORKS INCLUDE HEREIN SHALL BE
EXECUTED ACCORDING TO THE PROVISION OF THE NATIONAL
PLUMBING CODE OF THE PHILIPPINES IMPLEMENTING RULES 2" Ø PVC PIPE
AND REGULATIONS.
C.O.

02. COORDINATE WITH THE DRAWING WITH OTHER RELATED OUTLET PIPE
DRAWINGS AND SPECIFICATIONS. THE ARCHITECT/S AND/OR MANHOLE MANHOLE

1.30
ENGINEER/S SHALL BE MODIFIED IMMEDIATELY OF ANY

1.10
C.O.
DISCREPANCY FOUND HEREIN HIS/HER SHALL BE FINAL.

03. ALL PIPES SHALL BE INSTALLED AS INDICATED ANY MANHOLE


RELOCATION REQUIREMENTS FOR PROPER EXECUTION OF CB 0.50m X 0.50m
OTHER TRADES SHALL BE WITH THE APPROVAL OF THE CO
ARCHITECT AND/OR ENGINEER.
F
KS INLET PIPE
04. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE
ACTUAL LOCATION , DEPTH AND ELEVATION OF EXISTING PIPES
AND STRUCTURES AS VERIFIED BY THE CONDUCTOR. CO
FD PLAN 4" Ø PVC PIPE

WC 3.00
05. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE F
REQUIRED FLOOR AND WALL OPENINGS. FD LAV 1.80 0.90
MANHOLE MANHOLE
06. ALL SLOPE FOR HORIZONTAL DRAINAGE SHALL BE 2" Ø PVC PIPE
MAINTAINED 1% AS MINIMUM, UNLESS OTHERWISE NOTED.

0.30
07. SIZES OF WATER SUPPLY TO THE FIXTURE SHALL BE IN
ACCORDANCE WITH THE MANUFACTURER'S INSTRUCTIONS. SCUM LINE
10mmØ HOR. & VERT.
08. ALL FIXTURES SHALL BE VENTED UNLESS OTHERWISE BARS SPACED AT 0.60m
NOTED. ST DIGESTING
CHAMBER BOTHWAYS O.C.
CB LEACHING
09. THE WORK THROUGHOUT SHALL BE EXECUTED IN THE
MOST THOROUGH MANNER KNOW TO THE TRADE AND TO THE
CO CHAMBER

1.80
WC

1.30
SANITARY OF THE ARCHITECT 0R ENGINEER.
FD
10. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES KS
AT SIDE AND COORDINATE WITH THE SEWER EFFLUENT SAND
DISPOSAL AND WATERLINE SERVICE CONNECTING POINT.
WC
KS 0.12M THICK
11. REFER TO TECHNICAL SPECIFICATION FOR DETAILED FD 3 - 12mmØ FOOTING
MATERIAL AND EQUIPMENT SPECIFICATION. BARS W/ 10mmØ TIES
SPACED AT 0.20m O.C.
CB CB

0.20
10 mm Ø RSB SPACED AT 0.20M OC 0.50
SECTION
PLUMBING LEGEND
DETAILS OF SEPTIC TANK
WC WATER CLOSET

FD FLOOR DRAIN CB CB
F
KS 0.50
CO CLEAN OUT
FD

M WATER METER PVC STORM


DRAIN PIPE
SP F

0.50
CWS
CV CHECKED VALVE FD WC FD LAV VSS INLET OUTLET
CO
CB CB
CWS
GV GATE VALVE VSS
F 12mm Ø LIFTING HANDLE 10mm Ø RE-BARS
LAV
F FAUCET 4 - 10mm Ø BOTHWAYS
NGL.
FD

ST SEPTIC TANK WC

0.10
SP 3 - LAYER OF 4" THK CHB SMOOTH
FD CEMENT SINGLE FACING FINISH
LAV LAVATORY
CO INLET

0.90
CB CB 4" Ø PVC PIPE
OUTLET
WASTE PIPE LINE TO DRAINAGE CV TO DRAINAGE

0.10
4" Ø PVC PIPE
M 4 - 10mm Ø BOTHWAYS
WATER SUPPLY LINE GV

FROM LOCAL
WATER SUPPLY

CATCH BASIN DETAIL


GROUND FLOOR PLUMBING LAYOUT SECOND FLOOR PLUMBING LAYOUT

CERTIFIED BY: PRC NO: 0015169 PROJECT TITLE AND LOCATION: APPROVED BY: REVISIONS: SHEET CONTENT: SHEET NO.
TIN: 612- 743- 115

PTR NO: 0060632 P-1


ENGR. JAN LESTER M. LOPEZ
PROPOSED TWO-STOREY RESIDENTIAL BUILDING AS SHOWN
ISSUED ON: 10- 06- 22 ALVIN KASILAG
6 9
REGISTERED MASTER PLUMBER ISSUED AT: SIPOCOT, CAM. SUR BRGY. IMPIG, SIPOCOT, CAMARINES SUR OWNER