You are on page 1of 1

5.

00
SVTR 2"Ø PVC S1000 0.10 1.00 1.00 3.00 0.10
GENERAL PLUMBING NOTES
VTR LEGEND
SVTR

0.10
1. ALL PLUMBING WORKS HEREIN SHALL BE EXECUTED
ACCORDING TO THE REQUIREMENTS OF THE PHILIPPINE
NATIONAL PLUMBING CODE 0.60
AND THE RULES AND REGULATIONS OF THE EXISTING 4"Ø PVC S1000 SANITARY WATER PIPE LINE
LOCAL CODES AND ORDINANCES. NOTHING CONTAINED
ON THE DRAWING SHALL BE CONSTRUED AS TO
W.C. LAV C.O.
CONFLICT WITH THE NATIONAL AND LOCAL
LAV C.O. LAV FRESH WATER PIPE LINE
ORDINANCES OR LAWS GOVERNING THE W.C. F.D. RAIN WATER PIPE LINE
IMPLEMENTATION OF THE PLUMBING WORKS.

2. REFER TO ALL ARCHITECTURAL, STRUCTURAL,


GUTTER LINE
ELECTRICAL, MECHANICAL PLANS AND SPECIFICATIONS M WATER METER
AND INVESTIGATE ALL POSSIBLE INTERFERENCE AND C.O. CB CATCH BASIN
CONDITIONS AFFECTING THE PLUMBING WORKS. VTR MANHOLE MANHOLE MANHOLE MANHOLE

0.60
1.90
3. IT IS NOT INTENDED THAT DRAWINGS SHALL SHOW F.D. VTR VENT THRU ROOF
EVERY PIPE FITTING, VALVE AND APPLIANCES. FURNISH 2"Ø PVC S1000 DS DOWN SPOUT
AND INSTALL, IF NECESSARY ALL ITEMS WHETHER
SPECIFICALLY MENTIONED OR NOT, OR INDICATED ON
URI F.D. FLOOR DRAIN
THE DRAWINGS, TO COMPLETE THE SYSTEM IN
ACCORDANCE WITH THE BEST PRACTICE OF THE W.C. WATER CLOSET
PLUMBING TRADE AND TO THE SATISFACTION OF THE W.C. LAV. LAVATORY DS
ARCHITECT.

4. PERFORM ALL LABOR IN A FIRST-CLASS, NEAT,


SHO SHOWER C.O. C.O.

WORKMANLIKE MANNER BY SPECIALISTS SKILLED IN


2"Ø PVC S1000
UR URINAL
THEIR TRADES, AND SUCH SPECIALISTS AND THEIR

0.10
WORKS SHALL BE SATISFACTORY TO THE ARCHITECT.

BASIC MATERIALS 6"Ø PVC S1000


1. PROVIDE MATERIALS THAT ARE NEW AND THAT PLAN
12MM DIA. MATTING BARS @0.20 M. BOTH WAYS O.C.
CONFORM
6"Ø PVC S1000
WITH THE STANDARDS OF THE UNDERWRITERS
LABORATORIES, INC.
VTR MANHOLE MANHOLE MANHOLE MANHOLE
C.O. C.O. C.O. C.O.
VTR

0.10
2. FOR OTHER MISCELLANEOUS REQUIRED MATERIALS
NOT SPECIFICALLY MENTIONED, PROVIDE THE BEST 4"Ø PVC S1000

0.30
OF THE RESPECTIVE KIND.
W.C. DS A I R S P A C E
3. SUBMIT SAMPLES OF THE MATERIALS FOR APPROVAL LAV 2"Ø PVC S1000 INLET
AS REQUIRED BY THE ARCHITECT.
SINK W.C. F.D. LAV
OUTLET
4. CONFORM ALL APPLICABLE PIPES AND MATERIALS
FOR VARIOUS SERVICES TO THE STANDARDS STATED C.O. 6"Ø PVC S1000 DIGESTIVE CHAMBER
HEREUNDER.

PLUMBING FIXTURES VTR 4"Ø PVC S1000 SETTLING TANK SETTLING TANK
C.O. F.D.
4" THK. CHB W/ PLAIN CEMENT PLASTER FIN. W/ 10MM

1.80
2"Ø PVC S1000

2.10
1. INSTALL ALL PLUMBING FIXTURES FREE AND OPEN IN DIA. VERT. BAR @ 0.40 M. W/ 10MM DIA HOR. BARS @
EVERY 3RD LAYER
A MANNER TO ACCESS FOR CLEANING, FURNISHING
WITH BRACKETS, CLEATS, PLATES AND ANCHORS
C.O. URI
REQUIRED TO SUPPORT THE FIXTURES RIGIDLY IN
6"Ø PVC S1000
W.C. C.O.
PLACE.

2. KEEP AWAY AT A SUFFICIENT DISTANCE BUT NOT LESS


THAN 1 2 INCH (12.7mm) ALL SERVICE PIPES, VALVES
DS
12MM DIA. MATTING BARS @ 0.40 M. BOTH WAYS O.C.
AND FITTINGS FROM SURFACES AND LOCATION WHICH
MAY REQUIRE FINISH COATS OR COVERING.
6"Ø PVC S1000 4"Ø PVC S1000

0.12
3. EXTEND THE PIPING TO ALL FIXTURES, OUTLETS AND
EQUIPMENT FROM REQUIRED GATE VALVES

0.20
INSTALLED IN EACH BRANCH NEAR RISERS.
6"Ø PVC S1000
SOIL, WASTE, DRAIN & VENT PIPING
ELEVATION

0.10
1. INSTALL ALL PIPING WORKS IN CONFORMITY WITH ALL 2 SEPTIC TANK DETAIL
PROVISIONS REQUIRED OF THE LATEST EDITION OF
THE PHILIPPINES AND APPLICABLE REQUIREMENTS OF P 2 SCALE 1:25 METERS
EXISTING LOCAL CODES.

2. EXCAVATE TO REQUIRED DEPTHS AND GRADES ALL


6"Ø PVC S1000
EXCAVATIONS REQUIRED FOR THE INSTALLATION OF
DS
PLUMBING AND DRAINAGE SYSTEM. WHEN ROCK IS 6"Ø PVC S1000
ENCOUNTERED, EXTEND EXCAVATION TO A DEPTH 2.00
150mm. BELOW THE PIPE BOTTOM AND BEFORE PIPE IS
LAID, FILL SAND AND OTHER APPROVED MATERIALS. 0.10
1.80 0.10

3. LAY WATER SUPPLY PIPES AND SEWERS IN SEPARATE


TRENCHES.

0.10
4. ALL HORIZONTAL PIPING SHALL BE RUN IN PRACTICAL
ALIGNMENT AND AT A UNIFORM GRADE OF NOT LESS
THAN TWO PERCENT (2%) OR 2cm PER METER
TOWARD THE POINT OF DISPOSAL.

PLUMBING PIPES & FITTINGS DS 6"Ø PVC S1000


1. FOR WATER LINES USE, POLYPROPYLENE (PPR) PIPES
AND FITTINGS CONFORMING TO STANDARD
DIMENSIONS, USING MANUFACTURER SPECIFIED CO
METHOD OF INSTALLATION & CONNECTION. MATERIAL
MANHOLE
BRAND IS POLYMUTAN OR APPROVED EQUAL..

2.00

1.80
2. SEWER PIPES, VENT FITTINGS AND TRAPS TO USE PVC
PIPES AND FITTING MATERIAL OF NELTEX, EMERALD
OR ATLANTA BRAND.

3. PVC JOINT CEMENT. MATERIAL BRAND, NELTEX,


EMERALD OR ATLANTA.

4. FLOOR DRAIN SIZE IS 100mm x 100mm STAINLESS


STEEL. 6"Ø PVC S1000
MATERIAL BRAND, METMA MODEL NO. M210 OR
APPROVED EQUAL.

SEP

0.10
5. WATER METER PROVIDED BY RLC.

6. AIR CHAMBER TO BE PROVIDED FOR ALL WATER LINES


OUTLETS ALL NECESSARY FITTING SHALL BE
PROVIDED. TIC PLAN
12MM DIA. MATTING BARS @0.20 M. BOTH WAYS O.C.
7. TEFLON TAPE FOR ALL WATER LINES CONNECTIONS
APPLIED TO MALE THREADS ONLY.
TA MANHOLE
C.O.

NK

0.10
8. STAINLESS STEEL SINK STRAINER MATERIAL BRAND,
BIG BOY USA OR APPROVED EQUAL.

9. APPLY PIONEER EPOXY FOR JOINT.


6"Ø PVC S1000
10. MAKE ALL JOINTS WATER TIGHT. FOR JOINING PIPES,
USE THE FOLLOWING: INLET
A. GALVANIZED IRON AND COPPER PIPES: CAREFULLY
REAMED THREADED JOINTS. APPLY TEFLON TAPE
I N G
LD NK
OR PAINT WITH RED LEAD AT ALL LENGTHS.
B. CEMENT PIPES: GROUT WITH CEMENT MIX ALL
O

1.60
AROUND THE JOINTS IN A CONSISTENT MANNER. DO
NOT ALLOW GROUT TO BULGE INSIDE PIPE H TA HOLDING TANK

2.04
INTERIORS
C. PVC PIPES: USE APPROPRIATE COUPLERS AND
4" THK. CHB W/ PLAIN CEMENT PLASTER FIN. W/ 10MM
GLUE AT JOINTS.
DIA. VERT. BAR @ 0.40 M. W/ 10MM DIA HOR. BARS @
SHUT-OFFS EVERY 3RD LAYER
11. THE THREADS OF DRAINAGE FITTINGS SHALL BE
TAPPED
PROVIDE TO ALLOW
THE ENTIRE TWO WITH
SYSTEM (2) PERCENT
VALVESOR
SO21mm/M
GRADE
LOCATED THAT THE SYSTEM OR PORTIONS OF IT

TER
CAN BE OPERATED, REPLACED AND REPAIRED, AS
WELL AS AFFORDING COMPLETE CONTROL OF
THE WATER SUPPLY TO EACH GROUP OF THE 6"Ø PVC S1000 A
W NK
N

0.34
FIXTURES. WHEN REQUIRED, PROVIDE ALSO
I
RA TA
PRESSURE REDUCING VALVES.

OTHERS

1. PIPES SHALL BE INSTALLED AS INDICATED.


ELEVATION
ANY RELOCATION REQUIRED FOR PROPER
EXECUTION OF OTHER TRADES SHALL BE
PRIOR APPROVAL OF ARCHITECT AND THE
DESIGNING PLUMBING ENGINEER.
3 HOLDING TANK DETAIL
2. PROPOSED SANITARY UTILITIES SHALL
CONFORM TO THE ACTUAL LOCATION, P 2 SCALE 1:25 METERS
DEPTH , AND INVERT ELEVATIONS. 1 ISOMETRIC SANITARY LAYOUT
3. ALL FIXTURES SHALL BE VENTED, UNLESS
OTHERWISE INDICATED. P 2 D N T S

MASTER PLUMBER PROJECT TITLE/ LOCATION: OWNER: SHEET CONTENTS: DRAWING NO.:

1. ISOMETRIC SANITARY LAYOUT

A PROPOSED TWO-STOREY COMMERCIAL BUILDING Sps. JOHN AND GEESNELL YAP 2. SEPTIC TANK DETAIL P 2
4
OWNER
SAN ISIDRO DISTRICT, TAGBILARAN CITY SHEET NO.:

THESE DRAWINGS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY AND DOCUMENT OF THE ARCHITECT. ADDRESS: SAN ISIDRO DISTRICT, TAGBILARAN CITY
IT SHALL BE UNLAWFULL FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT
OR AUTHORS OF THE SAID DOCUMENT TO DUPLICATE OR COPY SAID INSTRUMENTS
12 18
SIGNATURE TIN: CTC NO. DRAWN: CHECKED: GWORKS

You might also like