You are on page 1of 1

1.

ALL PLUMBING WORKS INCLUDED HEREIN SHALL BE COLD WATER LINES GALVANIZED IRON PIPES (GIP)' SCHEDULE
EXECUTED ACCORDING TO THE PROVISIONS OF THE 40 CONFORMING TO ASM A-120.
PHILIPPINE PLUMBING CODE, THE NATIONAL BUILDING STEEL COVER
CODE AND THE RULES AND REGULATIONS OF THE HOT WATER LINES REHAU PIPES 75. 0mm
4" THK. CHB THK. SLAB
LOCAL AUTHORITY CONCERNED.
PLASTER FINISH
2. COORDINATE THE DRAWINGS WITH OTHER RELATED SEWER/ WASTE LINES PVC PIPES, SERIES 1000, EMERALD BRAND
DRAWINGS AND SPECIFICATIONS. OR APPROVED EQUAL.

0.10
THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY OF ANY
E
DISCREPANCY FOUND THEREIN PRIOR TO INSTALLATION. DOWNSPOUT PVC PIPES, SERIES 1000, EMERALD BRAND N K
L I E E IT)
Y C R ERM

0.30
R P
OR APPROVED EQUAL. A T O RY
I T D P , ANIT

0.40
N S
S A 0 0 ØRIFY
3. ALL PIPES AND FIXTURES SHALL BE INSTALLED AS 1 VE
(

INDICATED ON THE PLANS. ANY RELOCATIONS REQUIRED VENT LINES PVC PIPES, SERIES 600, EMERALD BRAND
VENTILATION

0.50
FOR PROPER EXECUTION OF OTHER TRADES SHALL BE OR APPROVED EQUAL. NK IC
TAEPT
S N K
E
L I E E IT)
Y C R ERM
WITH PRIOR APPROVAL OF THE ARCHITECT OR R
A T O RY
I T P , ANIT
P

ENGINEER. DRAINAGE LINES CONCRETE DRAINAGE PIPES A NØ DFY S


S 5 RI
1 VE
( K
EE IT)
CR M
FC
O O ER
ET YP
50mm THK.
4. PROPOSED SANITARY UTILITIES SHALL CONFORM TO THE WATER METER MWSS APPROVED A
LIN ITR
RY SAN
Y
SLAB WI TH POLYURETHANE WALL
NIT IF
ACTUAL LOCATION, DEPTH AND INVERT ELEVATIONS OF SA VER
( 10mmØ REBARS 0.10 0.30 0.10
ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY GATE VALVES CRANE BRAND OR APPROVED
THE CONTRACTOR. EQUAL 0.50
SECTION CONCRETE WALL
5. ALL SLOPES FOR THE HORIZONTAL DRAINAGE PIPES
SHALL MAINTAIN 2% UNLESS OTHERWISE SPECIFIED.
0.50 0.80
6. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN
L
ACCORDANCE WITH THE MANUFACTURER'S
INSTRUCTIONS. A

2% SLOPE

0.40
7. ALL PIPE SIZES ARE IN MILLIMETERS UNLESS OTHERWISE A
G
E
N
I N

0.10
SPECIFIED. D
R
A

A
L A
N
A
C
N
E
O
P C
R
E
T
E
I M
R
E
P

N
TYPICAL OPEN PERIMETER
E
2 CONCRETE CANAL DETAIL
P P 02 SCALE: nts

4.00 6.00
2.00 2.00
1.50 4.50
0.60
400x400mm MANHOLE
COVER W/ 12mmØ REBARS 400x400mm MANHOLE 150mm THK. TOP SLAB
(PROVIDE HADLE BARS) COVER W/ 12mmØ REBARS W/ 12mmØ REBARS @
100Ø PVC OUTLET PIPE (PROVIDE HADLE BARS) 250mm O.C.B.W.

0.30 MIN.
O
FC
O FC TO STREET SEWER

0.30 MIN.
VARIES
0.15
LEACHING
CHAMBER 01 100Ø C.O. 100Ø C.O.
I SOMETRI C LAY OUT M.H. GRADE LINE

1.50
0.60

@ SITE
01

VERIFY

0.10
P 02 SCALE: 1:300 METERS 100Ø PVC 100Ø PVC OUTLET PIPE AIR SPACE
100mm CHB PARTITION M.H.

0.15
WALL W/ 10mmØ VERT. LEACHING TO STREET SEWER SCUM LEVEL 100Ø PVC
& HOR. BARS @ 600mm CHAMBER 02 INLET PIPE
WATER
100Ø PVC 100mm CHB INTERIOR WALL W/ LEVEL

2.00
PLASTIC SLAT 10mmØ VERT. @ 400mm & HOR.

1.70
100mm M.H. BARS @ 600mm RESPECTIVELY DIGESTIVE

6.00
4" THK. CHB THK. SLAB LEACHING CHAMBER
PLASTER FINISH CHAMBER 01
150mm CHB PERIMETER 150mm CHB EXTERIOR WALL W/
WALL W/ 10mmØ VERT. 10mmØ VERT. @ 400mm & HOR.
& HOR. BARS @ 600mm BARS @ 600mm RESPECTIVELY

4.50
DIGESTIVE CHAMBER

0.20
3 - 10mmØ CONT.
C.O. BARS W/ 10mmØ TIES
0.30
0.10 0.30

@ 2 50 mm. O. C.
0.40

150mm THICK R.C. SLAB ELEV A T I ON


W/ 12mmØ STEEL REINF.
BAR 250mm O.C.B.W. 100mm THK. BOTTOM
SLAB W/ 10mmØ TEMP
BARS @ 400mm O.C.B.W.
100Ø PVC INLET PIPE
50mm THK.
PLAN
SLAB WI TH
10mmØ REBARS 0.10 0.30 0.10
OPEN CONCRETE FOR SALES QUOTATION

0.50 02 CANAL DETAIL 03 SEPTIC TANK DETAILS PURPOSESONLY.NOT VALID


FOR APPROVAL OF PLANS.
P 02 SCALE: NTS P 02 SCALE: NTS
SECTION
CIVIL ENGINEER PRC : PROJECT TITLE / LOCATION OWNER / ADDRESS CADD DfD
: SHEET CONTENTS REVISIONS SHEET NO.
P H I L I P P I N E PTR : Poultry Agriframe Building System LUCKY 5 / MR.CARLO JmC
CHECKED BY: No. PARTICULAR ( S ) : DATE : 02
STEELFRAMI NG
CORPORATION TIN : (PABS - BROILER Model) SANTIAGO RlM
APPROVED BY: AS SHOWN
Tunnel VentilatedI-Type
( ) BP 02
I SO 9001:2015
PCAB No.36112
ISSUED ON :
ISSUED AT :
BUGALLON , PANGASINAN BUGALLON , PANGASINAN
DATE:
DfD
DESIGNED BY:
BUILDING PLAN1 PABS - PSC - SO #:

You might also like