You are on page 1of 1

C 2 CIVIL NOTES

4 SCALE NTS

N
PROPERTY LINE

PROPERTY LINE
THESE GENERAL NOTES ARE INSTRUCTIONS TO THE CONTRACTOR AND
APPLY GENERALLY TO ALL THE WORK UNLESS MORE SPECIFIC
INFORMATION IS SHOWN IN DRAWINGS OR WRITTEN IN THE
SPECIFICATIONS, STANDARDS AND/OR CONTRACTS. 1.5 M x 2.4 M x 2.0 M
Y SEPTIC TANK Y
1.1) ALL CONSTRUCTION WORKS SHALL BE IN ACCORDANCE WITH THE A B C A B C
CURRENT DWG'S, SPEC'S AND STANDARDS AS MODIFIED BY THE
ARCHITECT/ENGINEER
1.2) AN APPROVED SET OF PLANS SHALL BE MAINTAINED ON THE JOB
6000 6000
STATE AT ALL TIMES. 3000 3000 750 3000 3000
1.3) ALL WORKS SHALL BE CONFORM TO THE BEST PRACTICE OF EACH
TRADE. UNLESS SHOWN OR NOTED OTHERWISE, CONSTRUCTION
DETAILS OR PRACTICES ARE COMMON TO THE STANDARD

1450
1.4) ALL WORKS SHALL BE CONFORM TO THE APPLICABLE CODES AND

900
AUTHORITY RULES. W W W W
2 2 2 2
1.5) THE CONTRACTOR SHALL OBTAIN THE NECESSARY PERMITS
REQUIRED FOR THE WORKS SHOWN ON THESE DRAWINGS PRIOR TO
1 1
THE START OF THE CONSTRUCTION.
1.6) THE CONTRACTOR SHALL LOCATE AND UNCOVER ALL THE
UNDERGROUND UTILITIES IN ADVANCE OF THE CONSTRUCTION IN
BEDROOM 1 BEDROOM 2

3000

3000
ORDER THE ARCHITECT/ENGINEER. W W
1.7) BACKFILLING SHALL NOT BE STARTED UNTIL NEWLY INSTALLED 2 2
UNDERGROUND EQUIPMENT IS CHECKED AND APPROVED BY THE

6" CHB FIREWALL

6" CHB FIREWALL


ENGINEERS TO VERIFY THEIR AND THEIR CORRECT
1.8) BACKFILL SHALL BE INSTALLED IN ACCORDANCE WITH THE RULING D D D D
2 2 2 2
STANDARDS.
1.9) DISPOSAL OF/AND STOCKPILING OF EXCESS MATERIAL WITHIN THE
2 2
PLANNING AREA SHALL BE DONE IN SUCH WAY THAT IT WILL NOT SERVICE D D SERVICE D D
4 3 4 3

2000

2000
CREATE A NUISANCE TO THE ONGOING WORKS IN THE GENERAL AND ENTRY ENTRY
NEIGHBORING SURROUNDING. T&B
1.10) THE CONTRACTOR SHALL NOT TRESPASS BEYOND THE PROJECT X X X X
BOUNDARY LINES UNLESS A PERMIT OR WRITTEN AUTHORIZATION HAS
DINING AREA
BEEN OBTAINED FROM THE NEIGHBORING PROPERTY OWNERS
INVOLVED. W W
1.11) ANY DAMAGE ON PUBLIC AREA AND/OR ON THE CLIENTS PREMISES
12000 3 3

12000
2000

2000
CAUSED BY THE ONGOING PROJECT WORKS SHALL BE RESTORED IN ITS KITCHEN T&B

6" CHB FIREWALL

6" CHB FIREWALL


ORIGINAL CONDITION, WITH NO ADDITIONAL COST IMPLICATION TO THE
CABINET UP
OWNERS INVOLVED, AS PER FOLLOWING REQUIREMENTS D D
1.12.1) ALL TREES IMPACTED BY THE ONGOING CONSTRUCTION WORKS 3 3
SHALL BE REPLACE IN THE SAME SIZE AND TYPE OF TREE AT THE SAME 3 3
LOCATION OR AT A NEW LOCATION GIVEN BY THE LOCAL AUTHORITIES D D
OR BY THE CLIENT. 2 2
1.12.2) ALL IRRIGATION SYSTEMS SHALL BE RESTORED TO FULLY
3000

3000
FUNCTIONING STATUS. W
2
MASTER'S W
2
1.12.3) ANY ROAD OR STREET CUTS ARE TO BE COORDINATED WITH THE LIVING ROOM BEDROOM
LOCAL AUTHORITIES, BACKFILLED ACCORDING STANDARDS ARE
REPAIRED TO ITS ORIGINAL STATUS.
1.13) ALL DIMENSIONS AND LEVELS ARE IN MILLIMETERS (MM) UNLESS
MENTIONED OTHERWISE.
1.14) THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS
4 W
4 W
1000

1000
D 2 D 2
AND LEVELS ON SITE (BOTH NEW AND EXISTING) AND REPORT
DISCREPANCIES TO THE ARCHITECT/ ENGINEER PRIOR TO PROCEEDING 1 1
OF WORKS. W W
1000

1000
1.15) THE CONTRACTOR SHALL REQUEST, FROM THE 1 1
PORCH
ARCHITECT/ENGINEER, NECESSARY DIMENSIONS NOT SHOWN. BENCHES
1.16) ALL ARCHITECTURAL DRAWINGS SHALL BE READ IN CONJUNCTION 5 FLOWER BOXES
5

775
WITH THE STRUCTURAL, SERVICES DRAWINGS AND SPECIFICATIONS MAIN MAIN
1300

FOR PROPER COORDINATION. ANY DISCREPANCIES SHALL BE BROUGHT ENTRY ENTRY


TO THE ATTENTION OF THE ENGINEER.
1.17) ALL DIMENSIONS OTHER THAN LEVELS ARE GIVEN TO STRUCTURAL
PROPERTY LINE

PROPERTY LINE
ELEMENTS. DIMENSIONS ARE TAKEN FROM AND TO CENTERLINES OF
COLUMNS, BEAMS, AND OTHER STRUCTURAL ELEMENTS; FROM FACES
OF WALLS AND EDGES OF OPENINGS UNLESS SHOWN OTHERWISE.
1.18) ALL LEVELS SHOWN IN THE DRAWING ARE FURNISHED FLOOR
LEVELS. CONTRACTOR SHALL ALLOW ADEQUATE CHANGES IN THE Y Y
STRUCTURAL FLOOR TO ACHIEVE INDICATED FLOOR LEVELS.
1.19) CONTRACTOR SHALL SUBMIT SHOP DRAWINGS “FOR APPROVAL”
PRIOR TO FABRICATION WHERE REQUIRED BY THE
ARCHITECT/ENGINEER.

C 2 GROUND FLOOR PLAN C 2 ROOF PLAN


5 SCALE 11 6 SCALE 1 1

DRAFTED AND ENGINEERED BY: PROJECT TITLE: OWNER: SHEET CONTENT/S: SET NO: SHEET NO:

PROPOSED ONE STOREY RESIDENTIAL BUILDING DERICK B. BALLOGAN GROUND FLOOR PLAN
JOHN D. RULLAN ROOF PLAN C2 2
CIVIL ENGINEER LOCATION: ADDRESS
PRC NO.: 0172118
PTR NO.: 7291230
VALIDITY: NOVEMBER 5, 2022
DATE: JANUARY 2021 POBLACION, DIADI, NUEVA VIZCAYA POBLACION, DIADI, NUEVA VIZCAYA 4 6 15
PLACE ISSUED: LA TRINIDAD, BENGUET

You might also like