GENERAL CONSTRUCTION NOTES

1.0 GENERAL REQUIREMENTS 5.0 NOTES ON CONCRETE MIXES AND PLACEMENT


1.1. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS
OTHERWISE SHOWN OR NOTED. MODIFY TYPICAL DETAILS AS DIRECTED TO MEET
SPECIAL CONDITIONS.
1.2. SHOP DRAWINGS WITH ERECTION AND PLACING DIAGRAMS OF ALL STRUCTURAL
STEEL, MISCELLANEOUS IRON, PRE-CAST CONCRETE ETC. SHALL BE SUBMITTED FOR
ENGINEER'S APPROVAL BEFORE FABRICATION.
1.3. CONTRACTOR SHALL VERIFY ALL DIMENSIONS BEFORE ALL WORK IS TO BEGIN, CHECK
WITH MECHANICAL AND ELECTRICAL CONTRACTORS FOR CONDUITS, PIPE SLEEVES,
ETC. TO BE EMBEDDED IN CONCRETE.
8.3. IF SLABS ARE REINFORCED BOTHWAYS, BARS ALONG THE SHORTER SPAN
1.4. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE ADEQUATE SHORING
SHALL BE PLACED BELOW THOSE ALONG THE LONG SPAN AT THE CENTER
AND BRACING OF THE STRUCTURE FOR ALL LOADS THAT MAYBE IMPOSED DURING
AND OVER THE LONGER SPAN FOR REINFORCING BARS NEAR THE
CONSTRUCTION.
SUPPORTS, THE SPACING OF THE BARS AT THE COLUMN STRIPS SHALL NOT
BE MORE THAN ONE AND A HALF (1 1/2) OF THE SLAB THICKNESS.
2.0 STANDARDS AND REFERENCES
8.4. TEMPERATURE BARS FOR SLAB SHALL BE GENERALLY PLACED NEAR THE
2.1. THE DESIGN, FABRICATION AND CONSTRUCTION OF THE PROJECT SHALL BE
FACE IN TENSION AND SHALL NOT BE LESS THAN 0.0025 X GROSS-SECTIONAL
GOVERNED BY NATIONAL STRUCTURAL CODE OF THE PHILIPPINES (N.S.C.P.). VOL 1,
AREA (Ag) OF THE SLAB (SEE SCHEDULE BELOW)
7TH EDITION 2015

3.0 DESIGN CRITERIA


3.1. LOADINGS
A. DEAD LOAD
CONCRETE 23.544 kN/m³
STEEL 76.93 kN/m³
150MM THK. CHB WALL 3.11 kPa
100MM THK. CHB WALL 2.89 kPa
B. LIVE LOAD
TYPICAL TO ROOMS 1.90 kPa
EXTERIOR CORRIDORS 2.90 kPa
ROOF LIVE LOAD 0.60 kPa
C. WIND LOAD
DESIGN WIND SPEED 270 kPh
E. SEISMIC LOAD
IMPORTANCE FACTOR =1, NUMERICAL FACTOR = 8.5
SEISMIC COEFFICIENT: Cv = 0.44Nv, Ca = 0.64Na
NEAR SOURCE FACTOR: Nv = 1.0, Na = 1.0
SEISMIC ZONE: Z = 0.40 (ZONE 4)
SOIL TYPE: S = D
3.2. DESIGN STRESSES
A. CONCRETE FOR FOOTING, COLUMNS, BEAMS, WALLS AND SLABS
COMPRESSIVE STRENGTH @ 28 DAYS fc' = 21 MPa (3,000 psi)
B. REINFORCING STEEL BARS
FOR BARS 16MMØ AND GREATER INTERMEDIATE GRADE DEFORMED BAR
fy = 276 MPa (40,000 psi)
FOR BARS LESS THAN 16MMØ fy = 235 MPa (33,000 psi)
C. STRUCTURAL STEEL, ASTM-A36
FOR PURLINS, TRUSSES, BRACING AND STRUTS
fy = 248 MPa (36,000 psi)
D. MASONRY UNIT (CHB)
NON-LOAD BEARING WALLS fm' = 3.45 MPa (500 psi)
E. WELDS: USED E-60XX ELECTRODES
F. STRUCTURAL BOLTS, ASTM-A307
fy = 620 MPa (90,000 PSI); Fnv = 372 mpA (54,000 si)

4.0 OTHER NOTES


4.1. IN THE INTERPRETATION OF THE DRAWING, INDICATED DIMENSIONS SHALL GOVERN
AND DISTANCES SHALL BE SCALED FOR CONSTRUCTION PURPOSES.
11.0 NOTES ON FOUNDATION
11.1.ALL FOUNDATION WORKS SHALL BE PROVIDED WITH A "LEAN CONCRETE" HAVING
THICKNESS OF 50MM (2") AND CONCRETE STRENGTH FC' = 13.8 MPA (2000 PSI).

12.0 MISCELLANEOUS NOTES

RA 544, ARTICLE 5, SECTION 33


PREPARED BY: SEAL: MISCELLANEOUS PROVISIONS, SPECIFICATION AND OTHER CONTRACT PROJECT TITLE: SHEET CONTENT: CONFORME:
DOCUMENTS.

MAC Structural Designs IT SHALL BE UNLAWFUL FOR ANY PERSON TO ORDER


OR OTHERWISE CAUSE THE CONSTRUCTION, AS SHOWN
and Engineering Services
RECONSTRUCTION, OR ALTERATION OF ANY BUILDING
OR STRUCTURE INTENDED FOR PUBLIC GATHERING OR
ASSEMBLY SUCH AS THEATERS, CINEMATOGRAPHS,
PROPOSED CONSTRUCTION OF
STADIA, CHURCHES OR STRUCTURES OF LIKE NATURE,

ENGR. MARK HEINTJE A. CUANAN


AND ANY OTHER ENGINEERING STRUCTURES
MENTIONED IN SECTION TWO OF THIS ACT UNLESS THE
DESIGNS, PLANS, AND SPECIFICATIONS OF SAME HAVE
TWO-STOREY RESIDENTIAL MRS. WARDA PANONDI
OWNER
BEEN PREPARED UNDER THE RESPONSIBLE CHARGE
Services Offered: Building Designs, CAD Drafting,
Structural Designs and other Engineering Services
CIVIL ENGINEER/STRUCTURAL DESIGNER
OF, AND SIGNED AND SEALED BY A REGISTERED CIVIL
ENGINEER, AND UNLESS THE CONSTRUCTION,
RECONSTRUCTION AND/OR ALTERATION THEREOF ARE
BUILDING SHEET NO. 6
Address: B11, L24, Summerville Subdivision, Lumbia, Cagayan de Oro City PRC: VALIDITY: EXECUTED UNDER THE RESPONSIBLE CHARGE AND
DIRECT SUPERVISION OF A CIVIL ENGINEER. PLANS AND
Mobile No: 09482110174/09352839502
PTR: PLACE: CDOC DESIGNS OF STRUCTURES MUST BE APPROVED AS
LOCATION: BAGUA II, COTABATO CITY, MAGUINDANO
Email: markcuanan@gmail.com
DATE: 11/20/2021 TIN:
PROVIDED BY LAW OR ORDINANCE OF A CITY OR
PROVINCE OR MUNICIPALITY WHERE THE SAID
STRUCTURE IS TO BE CONSTRUCTED. OWNER: MRS. WARDA PANONDI