You are on page 1of 1

ELECTRICAL NOTES

-THE ELECTRICAL INSTALLATION SHALL BE DONE IN ACCORDANCE


WITH THE PROVISIONS OF THE LATEST EDITION OF THE PHILIPPINE
ELECTRICAL CODE AND WITH EXISTING ORDINANCES,RULES AND
REQUIREMENTS OF THE POWER AND TELEPHONE COMPANIES.

-THE MAIN DISTRIBUTION PANEL TO BE SUPPLIED SHALL BE 230VAC


SINGLE PHASE, 3 WIRES, 60-HERTZ OVERHEAD TYPE.

-THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION


OF SERVICE ENTRANCE FOR PROPER CONNECTION OF SERVICE DROP
b b
AND METER.
WH WH
S
b b CU WP
ACU
CO -ALL WIRING SHALL BE INSTALLED IN STANDARD OR PVC , RIGID PVC CONDUIT
S 12
a S

9
Sab
SCHEDULE 40 RS CONDUITS WHICH IT SHALL BE RUN EMBEDDED INSIDE THE

10
3WS Sab 6
a

b b
REF CO
CONCRETE, SLABS, COLUMNS, WALLS AND PARTITIONS AND/OR RUN CONCEALED BET.
2 3WS
b b CO 11 DOUBLE WALL WOODEN PARTITIONS AND INSIDE THE CEILING SPACES.
S S CO CO
4 5 -ALL MATERIALS TO BE USED SHALL BE BRAND NEW AND OF THE
b b
WP APPROVED TYPE FOR LOCATION AND PURPOSES.
WP CO CO CO
3
a a -STANDARD TYPE OF ACCESSORIES, SPLICING DEVICES TERMINATIONS
3WS

1 BUSHINGS, COUPLINGS, SUPPORTS, CABLE TIES, WIRE/CAVBLE MARKERS


b CO CO
Sab b
7 8
CO AND OTHER APPURTENANCES FOR THE ENTIRE ELECTRICAL INSTALLATION
Sab
3WS
SHALL BE USED.
ACU ACU CO
CO
b b
a -UNLESS OTHERWISE SPECIFIED, THE MINIMUM SIZE OF WIRE AND CONDUIT
WP
SHALL BE NO.2.0mm TW(12 AWG) AND 15mm.(1/2") DIA. PVC RESPECTIVELY.

-WHEREVER REQUIRED AND NECESSARY, PULL/JUNCTION BOXES OR SLEEVES OF


APPROPRIATE SIZE SHALL BE INSTALLED AT CONVENIENT AND APPROPRIATE
LOCATIONS ALTHOUGH THEY ARE NOT SHOWN ON THE PLANS.

-THE ELECTRICAL WORKS SHALL BE DONE UNDER DIRECT AND IMMEDIATE


SUPERVISION OF A LICENSED ELECTRICAL ENGINEER.

-ALL EQUIPMENTS AND PANELS SHOULD BE GROUNDED SEPARATELY.


AND PROVIDE GROUND ROD FOR THE ELECTRICAL SYSTEM.

-ALL WALL OUTLETS SHALL BE INSTALLED AT THE FOLLOWING HEIGHTS


ABOVE THE FINISHED FLOOR LEVEL UNLESS OTHERWISE NOTED :

LIGHTING LINE LAYOUT POWER LINE LAYOUT b. TV,INTERCOM,TELEPHONE AND RECEPTACLE OUTLET -------- 300 mm.
SCALE 1:100 MTRS. SCALE 1:100 MTRS.
c. AIR COND. & CONTROL SWITCH OUTLETS -------- 1500 mm.

d. PANELBOARD & BREAKER (TO THE TOP) -------- 1800 mm.

e. LIGTHS CONTROL SWITCHES -------- 1200 mm.

RISER DIAGRAM -PROVIDE/INSTALL 13 mm.(1/2") DIA. EMT CONDUITS FROM EACH AHU TO C.U
SCHEDULE OF LOADS OF THE SAME COOPERATING SYSTEM FOR CONTROL WIRES.

-PROVIDE ALL WET AREAS SUCH AS TOILET AND WASH WITH


W E GROUND FAULT CURRENT INTERRUPTER(GFCI) AT 10mA SENSITIVITY.

-PROVIDE AIRCONDITION UNIT WOODEN BOX BEFOR INSTALLATION


OF THE ACU EQUIPMENT.REFER THE SIZE APPROPRIATE TO UNIT.
S -THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE
FOR THE PREPARATION OF AS BUILT PLAN AFTER THE
PROJECT IS FINISHED TO BE SUBMITTED TO THE OWNER.

LEGEND
WALL LAMP

CIRCULAR LAMP

PIN LIGHTS
Sa ONE GANG SWITCH

Sab TWO GANG SWITCH


Sabc THREE GANG SWITCH
3ws THREE GANG SWITCH

WP CONVENIENCE OUTLET
COMPUTATION CONVENIENCE OUTLET
CO
CU COOKING UNIT

REF REFRIGERATOR
CIRCUIT RUN
M KILOWATT HOUR METER
LOCATION
SCALE
MAP
NTS ACU ACU

SEAL: IMPORTANT: PROJECT TITLE: CONFORMED: SHEET CONTENT: SHEET NO.:

AS SHOWN
PROFESSIONAL ELECTRICAL ENGINEER
RA 545, SEC 25: THESE DRAWINGS, AS INSTRUMENTS OF
SERVICE, ARE THE PROPERTY & DOCUMENTS OF THE AUTHOR. IT
PROPOSED:
"BUNGALOW RESIDENTIAL"
5
SHALL BE UNLAWFUL FOR ANY PERSON, WITHOUT WRITTEN OR MR. RICHIE AGCAOILI
PRC NO. TIN: PRIOR CONSENT OF THE AUTHOR, TO DUPLICATE OR COPY E 1
SAID DOCUMENTS. Owner:
PTR NO. ISSD ON:
VALIDITY: ISSD AT: Address: LUBNAC VINTAR, ILOCOS NORTE