You are on page 1of 1

GENERAL NOTES: LEGEND AND SYMBOLS

PANEL NAME: P
ALL ELECTRICAL WORKS HEREIN SHALL BE IN ACCORDANCE WITH THE
14 WATTS LED BULB IN 6" DIA. PINLIGHT VOLT: 220 POLE: 3 PHASE: 3
NATIONAL BUILDING CODE, PROVISION OF THE LATEST APPROVED EDITION
OF THE PHILIPPINE ELECTRICAL CODE, THE LAWS AND ORDINANCES OF THE
MAIN BREAKER: 30 AT 3P 50 AF 220V 22 KAIC
LOCAL CODE ENFORCING AUTHORITIES AND REQUIREMENTS OF THE LOCAL ORBIT FAN (BY OTHERS)
POWER, TELEPHONE COMPANY AND BUILDING ADMINISTRATION FEEDER: 3 - 8 mm2 THWN ( PHASE ) , 1- 5.5 mm2 THWN (GROUND) 32 mmØ IMC
REQUIREMENTS.
COVE LIGHTS PANEL BOARD CKT CIRCUIT BREAKER RATING NUMBER
LOAD SERVE KW KVA
AMPERE LOAD SIZE OF WIRE
IMC
1. POWER SERVICE TO THE BUILDING SHALL BE 220V3Ø (L-L) ,3 WIRE + GRD., 60 HERTZ. DETAILS NO.
AT AF P KAIC TYPE CO LTG S 3Ø ØAB ØCA ØBC PHASE GROUND PIPE
2. ALL WORKS SHOULD BE DONE UNDER DIRECT SUPERVISION OF LICENSE REGISTERED ELECTRICAL RECHARGEABLE EMERGENCY LIGHT mmØ
mm² THHN mm² THHN
ENGINEER OR REGISTERED MASTER ELECTRICIAN 10WATTS
3. FINAL LIGHTING FIXTURES AND WIRING DEVICES SHALL BE APPROVED FOR LOCATION. SB 1 20 50 2 14 B-ON 1 3 COVE LIGHTS 8-FL 40x1 , 2-FL 20x1 0.45 0.45 2.04 2- 3.5 1- 3.5 15
SWITCH BANK NT
4. LOCATE ALL SPLICING BOXES TO ACCESSIBLE PLACE OR WITH ACCESS PANELS. 30 AT 3P 2 20 50 2 14 B-ON 17 3 17 SETS- 14 WATTS LED BULB 6" DIA. PINLIGHT, 1- EXIT LIGHT 0.25 0.25 1.13 2- 3.5 1- 3.5 15
16 S. LUGS 220V
5. THIS DRAWING ARE DIAGRAMMATIC LAYOUT ONLY. VERIFY SITE ACTUAL LAYOUT PANEL BOARD 3 20 50 2 14 B-ON 16 1 COVE LIGHTS 8-FL 40x1 0.40 0.40 1.82 2- 3.5 1- 3.5 15
6. ALL POWER OUTLET (C.O) SHOULD BE 700 MM FAR FROM EDGE OF SINK, OTHERWISE PROVIDE RESIDUAL P
20 AT 2P 20 AT 2P 4 20 50 2 14 B-ON 1 1 WALL EXAUST FAN 0.02 0.02 0.09 2- 3.5 1- 3.5 15
CONVENIENCE OUTLET EXIT LIGHT 1 2
7. IN KITCHEN AREA/ ROOM ALL METAL OF REF, CABINETS, AIRCON FRAMES, BLOWER FRAMES 20 AT 2P 20 AT 2P
5 20 50 2 14 B-ON 1 HAND DRYER 1.20 1.20 5.45
GROUND FAULT CIRCUIT INTERRUPTER
SHALL BE PROPERLY GROUNDED WITH MINIMUM GROUND BONDING JUMPER OF # 3.5mm2 STRANDED AND GFCI 3 4 6 20 50 2 14 B-ON 16 6 8- 14 WATTS LED BULB 6" DIA. PINLIGHT, 1- LED STRIP LIGHT 9W 0.27 0.27 1.22 2- 3.5 1- 3.5 15
CONVENIENCE OUTLET 20 AT 2P 20 AT 2P
TAP TO PANEL BOARD GROUND TERMINAL LUGS. 2-FL 40x1 , 2- EMERGENCY LIGHT, 2- TOIELT EXH FAN
HD GROUND FAULT CIRCUIT INTERRUPTER 5 6
8. ELECTRICAL CONTRACTOR TO CONDUCT TEST WITH REPRESENTATIVE OF OWNER OR CONSULTANTS, GFCI
HAND DRYER OUTLET 20 AT 2P 20 AT 2P 7 20 50 2 14 B-ON 3 CONVENIENCE OUTLET 0.54 0.54 2.45 2- 3.5 1- 3.5 15
THE FOLLOWING TEST TO BE DONE BEFORE OR AFTER ENERGIZATION. 7 8
20 AT 2P 20 AT 2P 8 20 50 2 14 B-ON 9 6 5- 14 WATTS LED BULB 6" DIA. PINLIGHT, 1- LED STRIP LIGHT 9W 0.19 0.19 0.86 2- 3.5 1- 3.5 15
A. WIRING INSULATION TEST
TOILET EXHAUST FAN 9 10 2-FL 40x1 , 1- EMERGENCY LIGHT
B. WIRING CONTINUITY TEST, INCLUDING GROUND WIRES 20 AT 2P 20 AT 2P
C. VOLTAGE/ POWER SUPPLY TEST AT PANELBOARD AND EVERY 11 12 9 20 50 2 14 B-ON 1 HAND DRYER 1.20 1.20 5.45 2- 3.5 1- 3.5 15
D. AMPERE LOAD TEST OF EACH CIRCUIT AND MAIN WIRE. GT 10 20 50 2 14 B-ON SPACE 15
E. PHASE SEQUENCE OR ROTATIONAL TEST REPORT
P CIRCUIT HOMERUN TO PANEL BOARD 16 S. LUGS
11 20 50 2 14 B-ON 4 4 ORBIT FAN WITH SWITCH CONTROL 0.08 0.08 0.36 2- 3.5 1- 3.5 15
9. ALL LOCATION AND MOUNTING HEIGHT ARE SUBJECT TO APPROVAL OF ELECTRICAL ENGINEER.
--
12 20 50 2 14 B-ON SPACE
10. USE OF FLEXIBLE METALLIC CONDUIT (FMC) SHALL BE LIMITED TO TWENTY FOUR (24) INCHES T.C.L. 4.60 4.60 6.48 7.36 7.03
11. ALL MATERIALS TO BE USE SHALL BE NEW AND APPROVED TYPE FOR LOCATION.
COMPUTATIONS : DEMAND FACTOR = 100 %
12. ALL WIRES SHOULD HAVE A MAXIMUM LOAD OF 80% OF WIRE CAPACITY I 3Ø = 100% DF x 7.36 + 25% x 0.18 = 7.4 AMPS
13. RECEPTACLES FOR GENERAL USE SHALL BE DUPLEX 20A 250VAC GROUND TYPE I CB = 125% x 7.4 = 9.25 AMPS
14. LIGHT SWITCHES MINIMUM RATING SHALL BE 10A 250VAC
15. ALL MATERIALS TO BE USE SHALL BE BRAND NEW AND HAVE A "P.S." MARKS
A. LIGHT SWITCHES - 1.37 M ABOVE FLOOR FINISH
B. CONVENIENCE OUTLETS - 0.30 M ABOVE FLOOR FINISH
C. TELEPHONE OUTLETS - 0.30 M ABOVE FLOOR FINISH
D. PANELBOARD - 1.80 M ABOVE FLOOR FINISH
16. CONDUIT/PIPE EMBEDDED WITHIN CONCRETE WALL SHALL HAVE A MINIMUM CEMENT
PLASTERED OF 20MM THICK.
17. ALL LIGHTING FIXTURES SHOULD HAVE INDEPENDENT HANGER / SUPPORTS.
18. ALL CONDUIT/PIPE ABOVE CEILING SHOULD HAVE INDEPENDENT HANGER/SUPPORTS.
19. ALL BOXES SHALL BE OCCUPIED ONLY OF 50% OF WIRES VOLUME.
20. WIRE VOLTAGE DROP SHALL BE LIMITED TO 3% FROM SOURCE TO PANELBOARD
21. ALL CIRCUIT BREAKER ARE BRAND NEW
22. ALL CONDUIT AND FITTINGS SHALL BE IMC FOR LIGHT AND POWER.
FOR TELEPHONE AND DATA SYSTEM, OR EQUIVALENT CONDUIT USED PVC
23. DOUBLE-COAT OF RUST-PROTECTIVE PAINT (RED-OXIDE PRIMER) ON HANGERS AND SUPPORTS.
24. WIRE COLOR CODING IS STRICTLY ENFORCE:
L1 - RED SWITCH - BROWN
L2 - YELLOW GROUND - GREEN
L3 - BLUE NEUTRAL - WHITE
RETURN SWITCH - BLACK
25. IN CASE OF ANY DISCREPANCY BETWEEN PLANS AND SITE CONDITION, SPECIFICATION
AND REVISIONS/ CHANGES, CONSULT TO ELECTRICAL ENGINEER. TAP / CONNECT TO EXISITING
EMERGENCY PANELBOARD
COORDINATE AND SECURE APPROVAL
P
WITH ENGINEERING DEPARTMENT
GT

THE SITE 3 - 8 mm2 THWN ( PHASE ) ,


PULONG, STA. CRUZ, STA. STA. ROSA
TOLL PLAZA
STA. ROSA 3 -1- 5.5 mm2 THWN (GROUND)
ROSA, LAGUNA TOLL PLAZA IN 32 mmØ IMC
(S.BOUND)
(N.BOUND) ( IF LENGTH EXCEED WITH ALLOWABLE
VOLTAGE DROP , INCREASE WIRE SIZE ) BCW # 5.5 mm2 (GREEN)
IN 15 mmØ IMC
SL
EX

VILLA IBARRA
BANNER D= 600 mm (Minimum) CONCRETE HANDHOLE
300 mm X 300 mm X 300mm
W/ REMOVABLE COVER

GROUND ROD 16 mmØ x 2400 mm


R= 5 ohms ( ADD ROD TO MEET REQ'TS)
SL
EX

TOYOTA

COCA-COLA HOT SISIGLICIOUS


2 POWER ONE LINE DIAGRAM
EATERY E-1 NOT TO SCALE
PAVILION

DATE ISSUED : 03-15-2021


GRAPHIC SCALE:
1:50 METERS
1 VICINITY MAP 0 0.50

1:100 METERS
1.00 2.00

E-1 NOT TO SCALE 0 0.50 1.00 2.00 4.00

COMPANY REPUBLIC ACT 545 SECTION 25(4)


DRAWINGS & SPECIFICATIONS DULY SIGNED, STAMPED OR SEALED
PROFESSIONAL ELECTRICAL ENGR: REG. No: 2683 PROJECT: SHEET CONTENT OWNER SHEET No.
AS INSTRUMENTS OF SERVICE ARE THE PROPERTIES AND
P T R No: 0694757-D PROPOSED
JAIROELYNN CONSTRUCTION and DOCUMENTS OF THE ARCHITECT, WHETHER THE OBJECT FOR WHICH
THEY ARE MADE IS EXECUTED OR NOT. IT SHALL BE UNLAWFUL
DATE: 01-04-2021 GENERAL NOTES
COCA-COLA BEVERAGES
FOR ANY PERSON, WITHOUT THE WRITTEN CONSENT OF THE
REHABILITATION OF OPERATION MALE VICINITY MAP
GENERAL SERVICES CORPORATION ARCHITECT OR AUTHOR OF SAID DOCUMENTS TO DUPLICATE OR TO
MAKE COPIES OF SAID DOCUMENTS FOR USE IN THE REPETITION
OF AND FOR OTHER PROJECTS OR BUILDING, WHETHER EXECUTED
PARTLY OR IN WHOLE.
RODOLFO J. RENOLLA
PLACE: QUEZON CITY
T I N : 112-117-301 LOCKER / CR
POWER ONE LINE DIAGRAM
LOAD SCHEDULE PHILIPPINES, INC. E-1
ADDRESS: # 8A EVERLASTING STREET, PRESIDENTIAL DECREE No. 49
TEL No. 414.54.48 DRAWN BY: CHECKED BY: LOCATION:
ROXAS DISTRICT,QUEZON CITY, FAX No. 415.56.86
"PROTECTION OF INTELLECTUAL PROPERTY"

METRO-MANILA, PHILIPPINES
WORKS OF ART, ARCHITECTURE, MODELS & DESIGNS ARE CREATIVE
WORKS AND CONSIDERED AS PART OF THE INTELLECTUAL
RJR PULONG STA. CRUZ, STA. ROSA, LAGUNA APPROVED BY: FILE NAME
PROPERTY OF THE AUTHOR DULY PROTECTED UNDER P.D. 49.

You might also like