3/4" Ø RSC CEILING LIGHT S2 DOUBLE GANG SWITCH
2P-40AT MCB 3. ALL WIRING EQUIPMENT AND FIXTURES WERE BRAND NEW OF THE
WALL LAMPS S3 THREE GANG SWITCH
SWITCH LINE
APPROVED TYPE BY PHILIPPINE STANDARD AGENCY FOR EVERY
FLOURESCENT
R.C. TERMINAL
INTENDED LOCATION AND PURPOSE.
CONVENEINCE OUTLET CIRCUIT LINE RUN INSIDE WALL OR UNDER FLOOR
POST CO
LIGHTING OUTLET 1 15A 15A 2 LIGHTING OUTLET
WP
WEATHER PROOF OUTLET CIRCUIT LINE RUN INSIDE WALL OR OVER CEILING
4.UNLESS OTHERWISE INDICATED IN THE PLAN , ALL CONVENIENCE
KILOWATT Ref
REFRIGERATOR OUTLET
LP
LOAD PANEL
OUTLET WERE PLACED 300MM ABOVE FLOOR LEVEL
HOUR METER MICROWAVE OUTLET SERVICE ENTRANCE
M M SE
1.50
CONVENIENCE OUTLET 5 20A 20A 6 CONVENIENCE OUTLET PANEL TO OUTLETS
LP
7. A SEPARATE SERVICE DROP WERE PROVISED FOR THE BUILDINGS
GRADE LINE ELECTRICAL WIRINGS
REF OUTLET 1HP 7 20A 20A 8 ACU
OUTLET 1
HP
8. ALL WIRINGS WERE CAREFULLY INSPECTED AND APPROVED BY
3 SINGLE LINE DIAGRAM COMPETENT ELECTRICAL INSPECTOR BEFORE THE CURRENT IS TURNED
1.20
E 1 ON AND AN APPROVAL BY THE BUREAU OF FIRE DEPARTMENT IS NEEDED
ACU SPARE
9 30A 30A 10
OUTLET 1
HP
0.25
15mm Ø x 3.0 M COPPER 900 mm X 900 mm RC
FOOTING WITH
CLAD GRD ROD 5-16mm O RSB BOTHWAY
CATARMAN
ROAD
4 CONVENIENCE OUTLET 4 230 720 3.13 20 2 50 2-3.5mm² THWN IN 15mmØ PVC
ALLEN-
ACIBAR'S CONSTRUCTION & SUPPLY 5 CONVENIENCE OUTLET 4 230 720 3.13 20 2 50 2-3.5mm² THWN IN 15mmØ PVC
6 CONVENIENCE OUTLET 1 230 180 0.78 20 2 50 2-3.5mm² THWN IN 15mmØ PVC
7 REF OUTLET 1HP 1 230 1000 4.35 20 2 50 2-3.5mm² THWN IN 15mmØ PVC
8 ACU OUTLET 1 HP 1 230 1100 4.78 30 2 50 2-5.5mm² THWN IN 15mmØ PVC
9 ACU OUTLET 1 HP 1 230 1100 4.78 30 2 50 2-5.5mm² THWN IN 15mmØ PVC
SPARE
ALLYING DEMAND FACTOR OF 80%IN EXCESS FOR MAIN PANEL PROTCTION USED :
N SITE IT 6720 X .80 =5376 MINIMUM AMPACITY OF MAIN FEEDER: 2P-40AT MCB
EVACUATION CENTER
SIGN AND SEALED: PRC No. PROJECT TITLE : OWNER / APPLICANT : SHEET CONTENTS : REVISIONS: SHEET No:
PTR No.
PROPOSED 2 STOREY RESIDENTIAL GENERAL NOTES, LEGENDS & VICINITY MAP
ISSUED ON MR. GERROUS REYES PANEL BOARD DIAGRAM P
WITH ROOFTOP SINGLE LINE DIAGRAM
PROFESSIONAL ELECTRICAL ENGINEER ISSUED AT
LOCATION : BRGY. BANTAYAN, SANISIDRO
MABUHAY, SAN ROQUENORTHERN
NORTHERNSAMAR
SAMAR BRGY. MABUHAY,
ADDRESS : BRGY. BANTAYAN,SAN
SANISIDRO
ROQUE NORTHERN
NORTHERN SAMAR
SAMAR
ELECTRICAL LOAD CALCULATION 1316