You are on page 1of 1

NOTES:

GENERAL NOTES
A REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION AND MOUNTING HEIGHTS OF ALL DEVICES. REFER TO IT
REPRESENTATIVE FOR EXACT LOCATION OF IT DEVICES. REFER TO AV DRAWINGS FOR A DETAILED LAYOUT OF CONDUIT AND
CABLE FOR AV DEVICES.
B REFER TO EACH RESPECTIVE SECTION FOR MORE DETAIL (WIRE SIZES, CONDUIT SIZES, ETC.).
C UNDERGROUND CONDUIT SHALL BE PVC. CONDUIT IN WALLS AND ABOVE CEILINGS SHALL BE EMT. EXPOSED CONDUITS SHALL
BE RGS.
D DIRECT BURIED LIGHTING CABLES SHALL BE; ARMORED SINGLE CORE CABLES WITH ALUMINIUM WIRE ARMORED.

LPGF1-14 2x1Cx16mm2 + 1Cx10mm2


DIRECT BURY
GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL GL
LPGF1-16

GL 2x1Cx16mm2 + 1Cx10mm2
DIRECT BURY

GL

GL
V6 V6 V6 V6 V6
GL

GL

T T GL

T T GL

T T
GL
T T
GL
2Cx16mm2 + 10mm2
T T R DIRECT BURY
R R R R R GL
R
LPGF1-3 V6
T T GL
T T T
R T T T
T T
T T T T
R T T T T GL
U T T
R T T T T T T T T T T
Y X R GL

2Cx10mm2 + 6mm2
DIRECT BURY
3 NOS 32MM PVC CONDUIT FOR GL
R TELECOM, DIRECT BURY
LPGF1-10
ATS-1
R
GL
2000mm X 1000mm X 1000mm
R TELECOM HANDHOLE

R GL
LPGF1-5
CONCRETE ENCASED
MDB-03 R
2x1Cx16mm2 + 1Cx10mm2
3000mm X 3000mm X V7 DIRECT BURY GL
R 2500mm MANHOLE
REFER TO 2/E6.01 EXISTING TELECOM MANHOLE

2 NOS. 32MM PVC CONDUIT FOR


GL TELECOM
R

R
GL
R

CONCRETE ENCASED
GL

32MM PVC CONDUIT FOR TELECOM,


DIRECT BURY GL
3
E6.04

GL
MDB-04
MDB-06
FUTURE MDB-07
0 11/1/2021 ISSUED FOR CONSTRUCTION
GL
3000mm X 3000mm X
2500mm MANHOLE
REV.
REFER TO 2/E6.01 DATE DESCRIPTION CHK'D CERT APP'D
GL
No.

1 PROPRIETARY NOTICE
E6.04 GL This drawing and the information contained herein are the exclusive property
ofNovel Non-Metallic Solutions and shall not be copied, reproduced or
GL
disclosed in any manner, or used for any purpose whatsoever, except with the
prior written authorization of Novel Non-Metallic Solutions. This drawing,
including any documentation, drawings, calculation or other information
GL
prepared or derived from the information contained herein shall be returned to
Novel Non-Metallic Solutions upon request.
GL
FUTURE MDB-10 PROJECT TITLE :
MDB-08
FUTURE MDB-11
FUTURE MDB-09
GL NOVEL NON-METALLIC SOLUTIONS MANUFACTURING FACILITY

GL LOCATION :
3000mm X 3000mm X
2500mm MANHOLE
REFER TO 2/E6.01
GL
KING SALMAN ENERGY PARK (SPARK)

PPMA1 2 GL OWNER :
E6.04
2-2" PVC CONDUIT
CHWP CNTRL PANEL
CONCRETE ENCASED NOVEL NON-METALLIC SOLUTIONS MANUFACTURING
LEF CNTRL PANEL
MCC-01 MDB-01 CHECKED BY : APPROVED BY :
AR: A.Aleidi Zaheer Ahmed
ST: H.Ahmed

J
2

J
MCC-02 E4.03 ME: Abbas.H
EE: S.Joseph
CHECKED DATE : APPROVED DATE :
-- --
3000mm X 3000mm X V7
2500mm MANHOLE
TR-04
SHEET TITLE : DRAWING NUMBER : REV
(TYPICAL OF 4)
REFER TO 2/E6.01 CONCRETE ENCASE
4 1 ELECTRICAL SITE PLAN E0.52 0
E6.04 E6.04 TR-06

ENLARGED ELECTRICAL SITE PLAN - NE


1 1 : 250