COLD WATER SCHEDULE WEST BUILDING COLD WATER SCHEDULE EAST BUILDING GENERAL NOTES PLUMBING LEGEND AND

COLD WATER SCHEDULE EAST BUILDING GENERAL NOTES PLUMBING LEGEND AND SYMBOLS F R A N K R. W E B B

A R C H I T E C T S
1. THE TOTAL INSTALLATION SHALL COMPLY WITH ANY AND ALL REQUIREMENTS OF THE LEGALLY CONSTITUTED AUTHORITIES HAVING SYMBOL ABBREV. DESCRIPTION w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
Plumbing System Friction Loss Plumbing System Friction Loss JURISDICTION INCLUDING 2010 CBC (CALIFORNIA BUILDING CODE) AND 2010 CMC/CPC (CALIFORNIA MECHANICAL AND PLUMBING CODE).
DETAIL No.
F.U.'s : 13.5 = 31 GPM F.U.'s : 133.5 = 75 GPM 2. THE CONTRACTOR SHALL VISIT THE SITE PRIOR TO BID AND SHALL THOROUGHLY FAMILIARIZE HIMSELF WITH THE EXISTING CONDITIONS DETAIL REFERENCE
UNDER WHICH HE WILL BE REQUIRED TO WORK. SHEET No.
A SECTION REFERENCE
Min. friction loss (psi) 25 (25psi for flushvalve, 15 psi for tank type) Min. friction loss (psi) 25 (25psi for flushvalve, 15 psi for tank type)
3. ALL INDICATED DIMENSIONS ARE APPROXIMATE AND ARE GIVEN FOR ESTIMATE PURPOSES ONLY. BEFORE PROCEEDING WITH THE P-1
WORK THIS CONTRACTOR SHALL CAREFULLY CHECK AND VERIFY ALL DIMENSIONS, SIZES, REQUIRED CLEARANCES AND SHALL STACK/RISER
Elev. above St. main (ft.) 5 (from civil plans) Elev. above St. main (ft.) 17.5 (from civil plans) PLUMBING STACK OR RISER REFERENCE
ASSUME FULL RESPONSIBILITY FOR THE FITTING OF ALL EQUIPMENT AND MATERIALS HEREIN REQUIRED TO OTHER PARTS OF THE
WORK OF OTHER TRADES. ID. No.
Daily St. High pressure (psi) 78 (from local water district) Daily St. High pressure (psi) 78 (from local water district) EQUIPMENT
Daily St. Low pressure (psi) 77 (from local water district) Daily St. Low pressure (psi) 77 (from local water district) 4. THE DRAWINGS ARE ESSENTIALLY DIAGRAMMATIC TO THE EXTENT THAT ALL OFFSETS, BENDS, SPECIAL FITTINGS AND LOCATIONS ARE EQUIPMENT REFERENCE
NOT EXACTLY LOCATED. ID. No.
Dist. from St. to highest 145 (from plans, in feet) Dist. from St. to highest 100 (from plans, in feet)
fixture FW FIRE WATER
fixture 5. IN THE PREPARATION OF THESE DOCUMENTS, CERTAIN ASSUMPTIONS ARE MADE REGARDING EXISTING CONDITIONS. SOME OF THESE
ASSUMPTIONS MAY NOT BE VERIFIABLE WITHOUT EXPENDING ADDITIONAL SUMS OF MONEY OR DESTROYING OTHERWISE ADEQUATE SCW SOFTENED / CONDITIONED COLD WATER
1 1/2" Meter pressure loss (psi) 6.5 (UPC Appendix A.1) 1 1/2" Meter pressure loss (psi) 13 (UPC Appendix A.1) OR SERVICEABLE PORTIONS OF EXISTING BUILDINGS AND/OR EQUIPMENT. THEREFORE, THE ENGINEER SHALL NOT BE HELD
CW COLD WATER
Backflow device loss (psi) 13 Backflow device loss (psi) 13 RESPONSIBLE FOR ANY CHANGES OR ADDITIONAL COSTS INCURRED DUE TO EXISTING CONDITIONS.
PRV device loss (psi) N/A HW HOT WATER
PRV device loss (psi) N/A 6. ITEMS RELATED TO PLUMBING UTILITIES AND/OR OTHER SERVICE(S); MATERIALS, LABOR, PERMITS, FEES, ETC., SHALL BE VERIFIED
WITH THE RESPECTIVE SERVING UTILITY COMPANY PRIOR TO SUBMISSION OF A BID. THE ACT OF SUBMITTING A BID SHALL CONSTITUTE HWR HOT WATER RETURN 8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
System static pressure loss (ft. hd.) 2.15 System static pressure loss (ft. hd.) 7.525 t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4
FULL RESPONSIBILITY OF THE CONTRACTOR TO INSTALL SERVICE(S) IN COMPLIANCE WITH THE REQUIREMENTS OF THE SERVING POP-OFF DRAIN LINE OR HIDDEN WATER LINE
UTILITY COMPANY AND THE MECHANICAL ENGINEER. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CHARGES LEVIED BY THE
Friction loss available to 30.35 Friction loss available to 18.475 SERVING UTILITY COMPANY EXCEPTING THE FIRST BILLING DEPOSIT. S or W SOIL or WASTE BELOW GRADE (or FLOOR)
THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
system system OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
7. THE CONTRACTOR SHALL COMPLY WITH ALL CONTRACT DOCUMENTS IN LAYING OUT HIS WORK AND EQUIPMENT. HE SHALL GW GW GREASE WASTE BELOW GRADE (or FLOOR) OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
Total developed length 203 Total developed length 140 COORDINATE THE WORK OF THIS SECTION WITH THE WORK OF OTHER TRADES AND ALL JOB CONDITIONS. CWV CWV COMBINATION WASTE AND VENT WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.
8. THE INSTALLATION OF ACCESS PANELS OR OTHER INDICATING EQUIPMENT OR SPECIALTIES REQUIRING READING, ADJUSTMENT, RD/OD RD/OD ROOF & OVERFLOW DRAIN ABOVE & BELOW GRADE (or FLOOR)
Friction loss/100 ft. 14.95 Friction loss/100 ft. 13.20
(max. friction loss allowable) (max. friction loss allowable) INSPECTION, REPAIRS, REMOVAL OR REPLACEMENT SHALL BE CONVENIENTLY LOCATED WITH REFERENCE TO THE FINISHED BUILDING. SD SD STORM DRAIN
Maximum velocity not to exceed 8fps. Maximum velocity not to exceed 8fps.
9. ALL EQUIPMENT AND FIXTURES INSTALLED UNDER THIS CONTRACT SHALL BE HUNG OR ANCHORED IN ACCORDANCE WITH TITLE 24, S or W SOIL or WASTE ABOVE GRADE (or FLOOR)
TABLE NO. 16 A-O. No. Distribution/Revision Date
V PLUMBING VENT
30% Design Review/Cost Estimate 8.15.2013
COLD WATER SCHEDULE WEST BLDG FUTURE COLD WATER SCHEDULE EAST BLDG FUTURE 10. THE INTENT OF THE DRAWINGS AND SPECIFICATIONS IS TO CONSTRUCT THE PROJECT IN ACCORDANCE WITH TITLE 24, CALIFORNIA
CODE OF REGULATIONS.
COND COND CONDENSATE DRAIN 65% Construction Documents
City Submittal
11.15.2013
12.17.2013
G G GAS LOW PRESSURE
11. WHERE MATERIAL IS SHOWN ON THE DRAWINGS BUT NOT SPECIFIED, IT SHALL BE OF THE SAME TYPE AND QUALITY AS EXISTING 100% Cost Estimate 4.18.2014
MPG MPG GAS MEDIUM PRESSURE
Plumbing System Friction Loss Plumbing System Friction Loss MATERIAL. City Submittal - Backcheck #1 05.05.2014
LPG LPG LIQUID PROPANE GAS 1 City Submittal 03.01.2017
F.U.'s : 80 = 62 GPM F.U.'s : 80 = 62 GPM 12. THE FIRE PROTECTION CONTRACTOR SHALL PROVIDE ALL REQUIRED HYDRAULIC CALCULATIONS AND FIRE SPRINKLER HEAD LOCATION AS AS AUTOMATIC FIRE SPRINKLER
IN ACCORDANCE WITH NFPA 13 TO THE LOCAL FIRE DEPARTMENT FOR REVIEW AND APPROVAL OF THE FIRE PROTECTION SYSTEM.
RW RW RECLAIM WATER
Min. friction loss (psi) 25 (25psi for flushvalve, 15 psi for tank type) Min. friction loss (psi) 25 (25psi for flushvalve, 15 psi for tank type)
13. TEST SYSTEM(S) IN ACCORDANCE WITH REQUIREMENTS OF THE GOVERNING AUTHORITIES. CA CA COMPRESSED AIR
Elev. above St. main (ft.) 5 (from civil plans) Elev. above St. main (ft.) 5 (from civil plans) 14. ALL CLEANOUTS SHALL BE INSTALLED WHERE READILY ACCESSIBLE AND LOCATED AS PER CODE REQUIREMENTS THE CONTRACTOR CAO CAO COMPRESSED AIR OUTLET
SHALL COORDINATE ALL CLEANOUT LOCATIONS WITH EQUIPMENT CABINETS, ETC. AND THE ARCHITECT PRIOR TO ANY INSTALLATION.
Daily St. High pressure (psi) 78 (from local water district) Daily St. High pressure (psi) 78 (from local water district) OX OX OXYGEN
Daily St. Low pressure (psi) 77 (from local water district) Daily St. Low pressure (psi) 77 (from local water district) 15. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND REPAIRING ALL PAVED AREAS WHICH ARE EXCAVATED AND/OR N2O N2O NITROUS OXIDE
DAMAGED BY HIS OPERATIONS. IN ADDITION, THE CONTRACTOR SHALL RESTORE TO THEIR ORIGINAL CONDITION ALL PLANTED AREAS
Dist. from St. to highest 145 (from plans, in feet) Dist. from St. to highest 100 (from plans, in feet) DAMAGED BY HIS OPERATIONS. MA MA MEDICAL AIR
fixture fixture VAC VAC VACUUM
16. ALL CONNECTIONS TO EXISTING SERVICES SHALL BE MADE SUCH THAT INTERRUPTION TIME WILL BE AS SHORT AS POSSIBLE. THE
CONTRACTOR SHALL GIVE THE OWNERS REPRESENTATIVE SUFFICIENT NOTICE OF SUCH INTERRUPTIONS AND THE ACTUAL SHUT- N2 N2 NITROGEN
2" Meter pressure loss (psi) 9 (UPC Appendix A.1) 2" Meter pressure loss (psi) 9 (UPC Appendix A.1)
DOWN TIME SHALL BE AT A TIME DESIGNATED BY THE OWNERS REPRESENTATIVE.
Backflow device loss (psi) 13 Backflow device loss (psi) 13 CS CIRCUIT SETTER 275 W. Hospitality Lane Suite #100
PRV device loss (psi) N/A PRV device loss (psi) N/A 17. ALL EXTERIOR WATER SHUT-OFF VALVES BELOW GROUND SHALL BE INSTALLED IN YARD BOXES WITH COVERS CONSPICUOUSLY SOV SHUT OFF VALVE San Bernardino, CA 92408
MARKED "WATER SHUT-OFF" RESPECTIVELY. Phone: 909.890.3700
System static pressure loss (ft. hd.) 2.15 System static pressure loss (ft. hd.) 2.15 SOV or GC SHUT OFF VALVE OR GAS COCK ON RISER
Fax: 909.890.3770
18. WHEN REQUIRED BY THE AUTHORITY HAVING JURISDICTION, POTABLE WATER SYSTEMS SHALL BE DISINFECTED AND FLUSHED PRIOR
Friction loss available to 27.85 Friction loss available to 27.85 TO USE BY WATER-CHLORINATION SOLUTION AND HAVE BACTERIOLOGICAL EXAMINATION MADE BY AN APPROVED AGENCY PER 2010 CV SWING CHECK VALVE email: info@designwesteng.com
system system CPC SEC. 609.9. PRV PRESSURE REDUCING VALVE
PTR PRESSURE-TEMPERATURE RELIEF VALVE
Total developed length 203 Total developed length 140 19. PLUMBING PIPE, FITTINGS AND FIXTURES USED TO CONVEY OR DISPENSE WATER FOR HUMAN CONSUMPTION SHALL COMPLY WITH AB
1953.
DESIGN WEST ENGINEERING
RPBFP REDUCED PRESSURE BACKFLOW PREVENTER MECHANICAL ELECTRICAL ENERGY CONSULTANTS
Friction loss/100 ft. 13.72 Friction loss/100 ft. 19.89
20. ANY SUBSTITUTION MADE BY THE CONTRACTOR THAT IS DIFFERENT FROM WHAT IS SPECIFIED ON THE DRAWINGS SHALL BE CLEARLY DN PIPE DOWN
(max. friction loss allowable) (max. friction loss allowable)
Maximum velocity not to exceed 8fps. Maximum velocity not to exceed 8fps. INDICATED ON THE SUBMITTAL AS TO ALL THAT IS BEING SUBSTITUTED.
UP PIPE UP
FESSIONA
FUTURE GREASE INTERCEPTOR SCHEDULE PIPE MATERIAL SCHEDULE DN TEE DOWN
ED
PRO
EN
M. J OH
L

EN
N

ER
UP TEE UP

GIN
V
REGI ST

SO
S TE
PRESSURE SHUT-OFF PIPE RISER & PIPE DROP (UP AND DOWN) No. 33209

EER
N
GI GI
MFR. & MODEL NO.: JENSEN PRECAST 500EE PIPE MATERIAL TYPE OF
1 2 SERVICE FITTING RATINGS VALVE FCO FLOOR CLEANOUT EXP. 9-30-2017
& WEIGHT JOINTS
CAPCACITY: 750 - 1500 GALLONS MATERIAL PSI - SwP ME
AT C H A N I CA N

L
WCO WALL CLEANOUT

IA
ST
BALL E O R
OPTIONS: W/ TRAFFIC RATED LIDS AND COLD WATER CAST BRONZE/ CO CLEANOUT PLUG F CA L I F O
COPPER L TUBE SOLDERED WROUGHT COPPER 125 GATE
ABV. GROUND
RISER RINGS AS REQ'D TO FLUSH W/ GRADE CHECK COTG YARD CLEANOUT or CLEANOUT TO GRADE
INSPECTION STATION COLD WATER CAP ON END OF PIPE
BELOW GROUND TO BRAZED CAST BRONZE/ BALL
COPPER K TUBE 125
GATE HB HOSE BIBB WITH VACUUM BREAKER
WATER HEATER SCHEDULE 5' OUTSIDE BUILDING WROUGHT COPPER
WHA & TP WATER HAMMER ARRESTOR & TRAP PRIMER

ELECTRICAL COLD WATER BV BALL VALVE


BELOW GROUND SCHEDULE 80 PVC SOLVENT-WELD PVC 125 GATE
TYPE MARK MFR MODEL VOLUME RECOVERY BTUH INPUT GAS WATTS VOLTAGE PHASE Hz OPERATING WEIGHT (LBS.) BEYOND 5'-0" GR GAS REGULATOR

GC GAS COCK (or GAS STOP)


SCREWED MALL. IRON 150 SQR HEAD
WH 1 A.O. SMITH DEL-10 10.0 gal 8.0 GAL./HR @ 80 deg TEMP RISE 1500 W 120 V 1 60 Hz 138 FUEL GAS STEEL 40, BLACK WELDED STEEL WELD 150 COCK GS GAS SOLENOID
WH 2 A.O. SMITH BTH-150 100.0 gal 192.0 GAL./HR @ 90 deg TEMP RISE 150,000 Btu/h 744 W N/AV
120 1 60 Hz 1389
P.O.C. POINT OF CONNECTION

CIRCULATION PUMP SCHEDULE VENT NO-HUB CAST IRON NO-HUB N/A N/A N/A P.O.D.
A.P.
POINT OF DEMOLITION

ACCESS PANEL
ELECTRICAL
WASTE & SCHEDULE 40 ABS SOVENT-WELD ABS N/A N/A ABV. ABOVE
TYPE MARK MFR MODEL PERFORMANCE CONSTRUCTION VOLTAGE PHASE Hz RPM AMPS DRY WEIGHT (LBS.) SOIL
DRAINS BEL. BELOW
BELOW GRADE NO-HUB CAST IRON NO-HUB N/A N/A N/A A.G.A. AMERICAN GAS ASSOCIATION
CP 1 TACO 007 70 GPM In-Line Pumps 115 V 1 60 Hz 3250 .76 7
WASTE & COPPER L TUBE SOLDERED BRONZE 125 N/A CONN CONNECTION
PLUMBING FIXTURE SCHEDULE SOIL
DRAINS NO-HUB CAST IRON NO-HUB N/A N/A N/A
CONT CONTINUATION

ABOVE GRADE (E) EXISTING


TAG SCHEDULED 40 ABS SOLVENT-WELD ABS N/A N/A
(N) NEW
TAG MARK SPECIFICATION WASTE TRAP VENT CW HW
CONDENSATE COPPER M TUBE SOLDERED BRONZE 125 N/A DN DOWN
H.C. HANDICAPPED
DF 1 Drinking Fountain: Haws model 1119.8 wall mtd., Hi-Lo dual bubbler chilled drinking fountain, 14 GA. type 304 stainless steel with satin 2" INT. 1-1/2" 1/2" -
IE INVERT ELEVATION
finish, polished chrome plated vandal-resistant bubblers (5703M), front push button (PBA2), polished chrome plated vandal- resistant
waste strainer (6462), vandal resistant bottom plates. ADA compliant PLUMBING PIPE INSULATION SCHEDULE (TYP) TYPICAL City of Torrance
Torrance Transit Park & Ride
FD 1 Floor Drain: Zurn Z-415BZ, 5-3/16" inch round top, Dura-Coated cast iron body with anchor fland and polished nickel bronze strainer. VARIES VARIES VARIES - - U.O.N. UNLESS OTHERWISE NOTED
Regional Terminal
Provide with trap primer connection. PIPE SIZE (IN. DIA.) VTR VENT THROUGH ROOF
465 Crenshaw Blvd.
TEMERATURE W/ WITH
FD 3 Floor Drain: JR Smith 3811C, 8 inch round top, duco cast iron with acid resistant coated interior. Provide with trap primer connection. VARIES VARIES VARIES - - RUNOUTS 1.25 2.5 Torrance, CA 90503
SERVICE 1 AND LESS
HB 1 Hose Bibb: Mifab exposed wall hydrant model MHY-90 rough brass finish with vacuum breaker and key operated control valve. - - - 3/4" - RANGE (F) UP TO 2 THRU 2 THRU 4 FU PLUMBING FIXTURE UNIT
SEC COND SECONDARY CONDENSATE
HB 2 Hose Bibb: Mifab exposed wall hydrant model MHY-90 rough brass finish with vacuum breaker and key operated control valve. - - - 3/4" - REQ. INSULATION THICKNESS (IN.)
JS 1 Service/Jan. Sink: Kohler "Whitby" K-6710 white enameled cast iron floor mounted service sink with K-8940 rim guard. Zurn Z842M4
service sink faucet w/ vacuum breaker, hose threaded outlet, pail hook & wall brace.
3" 3" 1-1/2" 3/4" 3/4"
DOMESIC HOT WATER RECIRCULATING LOOPS ABOVE 105˚ 0.5 1.0 1.0 1.5
PLUMBING SHEET INDEX Torrance Transit
L 1 Lavatory: American Standard "Lucerne" 0355.012, white vitreous china, wall hung lavatory w/ faucet holes on 4" centers. Technical 2" 1-1/4" 1-1/2" 1/2" 1/2"
Concepts AutoFaucet 500484 (0.5 GPM), w/ thermostatic mixing valve (402188), 120V AC power adapter, grid strainer drain w/ 1-1/4"
FIRST 8 FEET OF PIPING FROM STORAGE & ELECTRIC
TRACE TAPE SYSTEMS (NON-RECIRCULATING)
ABOVE 105˚ 0.5 1.0 1.0 1.5 Sheet # Sheet Name Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

cast brass P-trap with chrome finish, angle stops w/ rigid riser. On ADA compliant provide Truebro Lav Guard per CPC Sec. 1504.2
L 2 Lavatory: Kohler "Verticyl" K-2881, white vitreous china, unercounter mount. Grohe "Allure Touchless" 36098000 faucet (0.4 gpm) w/ 2" 1-1/4" 1-1/2" 1/2" 1/2"
PLUMBING SIZING FORM EAST BUILDING
P-001
P-101
PLUMBING LEGEND NOTES & SCHEDULES
PLUMBING SITE PLAN Regional
K-13601 temperature mixing valve set temperature limit stop in faucet to 110° grid strainer drain w/ 1-1/4" cast brass P-trap with chrome P-201 PLUMBING FLOOR PLAN - WEST BUILDING

L 3
finish, angle stops w/ rigid riser. On ADA compliant provide Truebro Lav Guard per CPC Sec. 1504.2
Lavatory: ACORN "Dura-Ware" 1953 series stainless steel wall mounted lavatory. ADA compliant. W/ deck-mounted spout, Technical 2" 1-1/4" 1-1/2" 1/2" 1/2"
PIPE SIZE IS BASED ON CHART A-4 @ 3.0 P.S.I. / 100 FT. P-202
P-301
PLUMBING ROOF PLAN - WEST BUILDING
FIRST FLOOR PLUMBING FLOOR PLAN - EAST BUILDING
Terminal
FIXTURE UNITS ARE BASED ON TABLE A-2 FROM APPENDIX A P-302 SECOND FLOOR PLUMBING FLOOR PLAN - EAST BUILDING
Concepts AutoFaucet 500484 (0.5 GPM), w/ thermostatic mixing valve (402188), 120V AC power adapter, grid strainer w/ tailpiece, and P-303 PLUMBING ROOF PLAN - EAST BUILDING CLIENT PROJECT #:B2013-15
tubular P-Trap PIPE SIZE SCHEDULE P-401 PLUMBING ENLARGED PLANS
FIXTURE UNITS
Keyplan
RD 1 Roof Drain: Mifab #R1200 large sump Roof Drain. Lacquered cast iron body w/ no-hub fitting, integral gravel stop, and self locking cast VARIES - - - - FIXTURE UNITS
P-402 PLUMBING ENLARGED PLANS CONTINUED
iron dome strainer. Overflow Drain: Mifab #R1200-R large sump Roof Drain with external 2" water dam. Lacquered cast iron body w/ NUMBER FIXTURE UNIT TOTAL
P-500 PLUMBING DETAILS
SIZE F. TANK F. VALVE GPM VELOCITY
no-hub fitting and self locking cast iron dome strainer. A
RD/OD 1 Roof Drain: Mifab #R1200 large sump Roof Drain. Lacquered cast iron body w/ no-hub fitting, integral gravel stop, and self locking cast VARIES - - - -
1/2"
3/4"
1
5
0
0
1.5
5
2.5
3.2
18
4
WC
U
5.0
4
90
16
PLUMBING SIZING FORM WEST BUILDING
iron dome strainer. Overflow Drain: Mifab #R1200-R large sump Roof Drain with external 2" water dam. Lacquered cast iron body w/ 13 0 10 4.0 15 L 1 15 PIPE SIZE IS BASED ON CHART A-4 @ 3.0 P.S.I. / 100 FT.
1" B
no-hub fitting and self locking cast iron dome strainer.
1-1/4" 24 0 17 4.5 3 SH 2 6
FIXTURE UNITS ARE BASED ON TABLE A-2 FROM APPENDIX A
S 1 Two Compartment Sink: Kohler "Toccata" K-3346, 33"x22" stainless steel double bowl sink, 19 gauge, self rim, punched for (4) holes on 2" 1-1/2" 1-1/2" 1/2" 1/2" 1-1/2" 47 10 27 5.0 2 JS 3 6
C
4" centers, Zurn Z82300-CP8-HS6 single handle faucet w/ hose and spray (1.5 GPM), chrome basket strainers w/ 1-1/2" cast brass L.A.
2" 158 64 56 6.0 1 DF 0.5 0.5 PIPE SIZE SCHEDULE
pattern P-trap with chrome finish, angle stops w/ rigid riser. FIXTURE UNITS D
2-1/2" 380 245 100 7.5 - - - - FIXTURE UNITS
SH 1 Shower: Best Bath shower pan P6337A75B w/ water stopper and removable dam, caulkless drain. Exterior dimensions: 63" (L) x 36" (W) 2" 1-1/2" 1-1/2" 3/4" 3/4" 3" 691 630 160 8.0 133.5
TOTAL FIXTURE UNITS SIZE F. TANK F. VALVE GPM VELOCITY NUMBER FIXTURE UNIT TOTAL E
x 4"(H). Grohe shower valve 35015000, Grohe "Essence" 19347000 shower trim & Grohe "Euphoria" 27492000 shower head (2.5 GPM).
4" 1171 1171 230 8.0 TOTAL G.P.M. 75 1/2" 1 0 1.5 2.5 1 WC 5.0 5.0
Watts LFUSG-B temperature mixing valve set temperature limit stop in faucet to 110°, escutcheon & chrome floor drain.
3/4" 5 0 5 3.2 1 L 1 1
TP 1 Trap Primer: Mifab model number "MR-500", 1/2" inlet and outlet with removable filter screen. May be located as indicated on drawings - - - 1/2" - VELOCITY FOR COLD WATER PIPING LESS THAN 8 FT. PER SECOND
or as required by code. UPC listed. For units serving (2) or more traps provide with Mifab distribution unit model "MI-DU-500". Provided 1" 13 0 10 4.0 1 JS 3 3
VELOCITY FOR HOT WATER PIPING LESS THAN 5 FT. PER SECOND
with a 12" x 12" access panel. 1-1/4" 24 0 17 4.5 1 1st HB 2.5 2.5
MAXIMUM SIZE FOR HOT WATER PIPING SHALL BE 1-1/2"
1-1/2" 47 10 27 5.0 2 2nd HB 1 2
U 1 Urinal: Kohler "Steward" K-4917, waterless urinal, ADA compliant, white vitreous china. Josam 17560-UR Urinal Carrier Floor Mounted 2" INT. 1-1/2" 1" -
Bearing Plate Type. 2" 158 64 56 6.0 TOTAL FIXTURE UNITS 13.5
380 245 100 7.5 31
U 2 Urinal: ACORN "Dura-Ware" 2158 series ADA compliant high efficiency urinal w/ Zurn GEG6003EV-HW6 sensor operated, hardwired
flush valve at .125 GPF
2" INT. 1-1/2" 1" - GAS LOAD SCHEDULE 2-1/2"
3" 691 630 160 8.0
TOTAL G.P.M.

Scale: 12" = 1'-0"


4" 1171 1171 230 8.0
Drawing Title
WC 1 Watercloset: Toto CT708E, ADA, 17" high rim, (1.28 GPF), wall mounted, elongated bowl, siphon jet, 1-1/2" top spud, white vitreous 4" INT. 2" 1" -
china. Sloan 8111-1.28 (1.28 GPF) Flush Valve, Olsonite plastic seat model 95 ComfortCurve, elongated, open front, stain & chemical
resistant. Jay R. Smith water closet support 0210.
SYMBOL ITEM LOCATION DEMAND (IN CFH)
VELOCITY FOR COLD WATER PIPING LESS THAN 8 FT. PER SECOND PLUMBING LEGEND
WC 3 Watercloset: ACORN "Dura-Ware" 2105 series stainless steel, off floor, siphon jet toilet. ADA 18" mount height. (1.28 GPF) w/ ACORN 4" INT. 2" 1" - WH-2 WATER HEATER JANITOR EAST BUILDING 150
VELOCITY FOR HOT WATER PIPING LESS THAN 5 FT. PER SECOND
MAXIMUM SIZE FOR HOT WATER PIPING SHALL BE 1-1/2"
NOTES &
flush valve option(-FV) and Hinged seat, open front less cover.
WHA 1 Water Hammer Arrestor: Mifab "MWH" series, installed on all quick closing valves and all valves which close with the flow of fluid or on - - - VARIES -
- EAST FUTURE T.I. LEASE SPACE 1738
SCHEDULES
headers serving more than one fixture. Provided with a 12" x 12" access panel. - WEST FUTURE T.I. LEASE SPACE 1565

- - - - IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE


Location
Drawing No.
TOTAL GAS LOAD 3453 CFH LA
6/26/2017 3:30:10 PM

Project Manager

SJ

P-001
LONGEST RUN LOW PRESSURE @ 2 PSI <330 FT. Project No.

13025
Date Plotted

06/26/2017

14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
1. ALL VENTING SHALL HAVE A MIN. OF 10' CLEARANCE FROM ANY FORCED AIR INLET W/ A
MIN. OF 3' CLEARANCE ABOVE & A MIN OF 4' CLEARANCE FROM ANY PROPERTY LINE
EXCEPT A PUBLIC WAY PER CPC SEC. 906.

2. ROOF DRAIN & PIPES ARE BASED ON TABLE 11 @ 3" OF RAIN FALL PER HOUR W 1/8" PIPE
SLOPE. SEE DETAIL # 13 ON SHEET P-500

3. COORDINATE EXACT LOCATION OF S.O.V. BACKFLOW DEVICE, WATER METER & GAS METER
WITH ARCHITECT.

4. SHUT-OFF VALVES SHALL BE PROVIDED ON ALL MAIN BRANCHES, RUN TOO RISERS AND
WHERE SHOWN ON DRAWING. LOCATE SHUT-OFF VALVES OVER T-BAR CEILING WHEN
POSSILE. PROVIDE ACCESS PANELS WHEN SHUT-OFF VALVES ARE LOCATION OVER HARD
LID CEILINGS.

8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4

THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND


ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.

No. Distribution/Revision Date


30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
100% Cost Estimate 4.18.2014
City Submittal - Backcheck #1 05.05.2014
1 City Submittal 03.01.2017

SEE CIVIL FOR CONTINUATION

GI
(FUTURE)
1

SEE CIVIL FOR CONTINUATION


1 275 W. Hospitality Lane Suite #100
San Bernardino, CA 92408
IE 73.36 Phone: 909.890.3700
Fax: 909.890.3770
4" GW
email: info@designwesteng.com
CAP 2" VENT BELOW GRADE
FOR FUTURE CONNECTION
TO GI-1
DESIGN WEST ENGINEERING
MECHANICAL ELECTRICAL ENERGY CONSULTANTS
2" VENT
IE 73.63
IE 74.08
GI
(FUTURE) FESSIONA
1 PRO
4" GW 4" COTG
CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER
1

GIN
V
REGI ST

SO
CAP 2" VENT BELOW GRADE

S TE
No. 33209

EER
N
FOR FUTURE CONNECTION 1
TO GI-1 4" W BELOW GRADE, SEE CIVIL FOR CONTINUATION. EXP. 9-30-2017
FOR WORK TO BE DONE IN 1
AREA SEE SHEETS ME
AT C H A N I CA N

L
2

IA
ST
1,2 1,2 1 1 1/2" CW RISER W/ HB ON RISER & APPROVED 1 1/2" CW S.O.V IN CONC.
E O R
1 P-301 P-302 P-303 YARDBOX SEE DETAIL 15 F CA L I F O
3"ø G P-500
3 4" RD & OD DN FROM ROOF TO BELOW GRADE AND DAYLIGHT
4"ø W
2 1/2"ø TP (11) 4" COTG 4 1" GAS UP IN WALL TO CEILING SPACE
1 1
5 4" FW CAPPED BELOW SLAB FOR FUTURE USE.
1 2
4" COTG 2" VENT 6 GAS LINE TO BE SIZED BY GAS COMPANY

7 CONTRACTOR TO COORDINATE WITH THE GAS COMPANY FOR TRENCHING AND


2-1/2" CW PIPING REQUIREMENTS
BELOW GRADE 3"ø G
1 1
IE 74.75 1"ø G
3"ø G
1
4" COTG
6

4" GW IE APPROXIMATLY 75.4' 7


CONNECT TO FUTURE GI-1
4 SEE CIVIL FOR CONTINUATION (EAST BUILDING FUTURE T.I. 1738 CFH)
2
(EAST BUILDING 180 CFH)
3
1 1/2"ø CW 4"ø FW
(WEST BUILDING FUTURE T.I. 1565 CFH)
3
2
1"ø G 3
FOR CONTINUATION SEE CIVIL PLANS 2 1/2"ø CW 4"ø FW City of Torrance
Torrance Transit Park & Ride
FOR CONTINUATION SEE CIVIL PLANS 1"ø G Regional Terminal
FOR WORK TO BE DONE IN
465 Crenshaw Blvd.
AREA SEE SHEET Torrance, CA 90503
1 2 1/2" CW BELOW
GRADE FOR DRINKING
P-201 P-202 FOUNTIAN, SEE
ARCHITECT.
Torrance Transit
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

Regional
Terminal
CLIENT PROJECT #:B2013-15

Keyplan
3" RD WITH DOWNSPOUT, SEE
CIVIL. TYPICAL OF 10.
A

Drawing Title Scale: 1/16" = 1'-0"

PLUMBING SITE
PLAN

IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE


Location
Drawing No.
LA
6/26/2017 3:30:11 PM

Project Manager

SJ
Project No.

P-101

N
13025
Date Plotted

06/26/2017

PLUMBING SITE PLAN 1/16" = 1'-0" 1


14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
1. CONDENSATE PIPING SHALL BE INSULATED.

2. ROUTE HOT WATER LOOP AS CLOSE AS POSSIBLE TO ALL FIXTURES.

3. ALL VENTING SHALL HAVE A MIN. OF 10' CLEARANCE FROM ANY FORCED AIR INLET W/
A MIN. OF 3' CLEARANCE ABOVE & A MIN. OF 4' CLEARANCE FROM ANY PROPERTY
LINE EXCEPT A PUBLIC WAY PER CPC SEC. 906.

4. ROOF DRAIN & PIPES ARE BASED ON TABLE 11 @4" OF RAIN FALL PER HOUR W/ 1/8"
SLOPE.SEE DETAIL # 13 ON SHEET P-500

5. COORDINATE EXACT LOCATION OF S.O.V. BACKFLOW DEVICE, WATER METER & GAS
METER WITH ARCHITECT.

6. PRIOR TO CONSTRUCTION CONTRACTOR SHALL FIELD VERIFY FOR EXACT SIZE,


LOCATION & INVERT ELEVATION OF EXISTING WASTE LINE & COORDINATE WITH
PLUMBING ENGINEER FOR ANY CHANGES NEEDED.
7. CONTRACTOR SHALL PATH FLOORS, WALLS & CEIINGS TO MATCH NEW CONTRUCTION
PER ARCHITECTS SPECIFICATIONS.
8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4
8. SHUT-OFF VALVES SHALL BE PROVIDED ON ALL MAIN BRANCHES, RUNS TOO RISERS
AND WHERE SHOWN ON DRAWING, LOCATE SHUT-OFF VALVES OVER T-BAR CEILING THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
WHEN POSSIBLE. PROVIDE ACCESS PANELS WHEN SHUT-OFF VALVES ARE LOCATED ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
OVER HARD LID CEILINGS. OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
14 OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
P-500 WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.

No. Distribution/Revision Date


30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
100% Cost Estimate 4.18.2014
City Submittal - Backcheck #1 05.05.2014
1 City Submittal 03.01.2017
2 Owner Revisions 06.23.2017

C.1 C.2 C.3 C.4 C.5 C.6 C.7 C.8

275 W. Hospitality Lane Suite #100


San Bernardino, CA 92408
12 Phone: 909.890.3700
Fax: 909.890.3770
12
email: info@designwesteng.com
12
4"ø GW
4" COTG 4" COTG 4" COTG
1 1 DESIGN WEST ENGINEERING
1 4"ø W MECHANICAL ELECTRICAL ENERGY CONSULTANTS

9 FW BY OTHERS, SEE
FIRE SPRINKLER PLANS
FESSIONA
PRO
H
CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER

GIN
V
REGI ST

SO
S TE
No. 33209

EER
N
E 1 2 1/2" CW RISER W/ HB ON RISER & APPROVED 2 1/2" CW S.O.V IN CONC
EXP. 9-30-2017
Main 4"ø W GREASE WASTE WASTE CAPPED FOR YARDBOX SEE DETAIL 15
CAPPED FOR FUTURE FUTURE USE. ME
Electrical AT C H A N I CA N

L
IA
ST
USE. P-500
Room E O R
Transit F CA L I F O
107
Store 11 2 CONNECT 3/4" CONDENSATE TO FAN COIL IN DIRECT WASTE CONNECTION.
Commercial
Storage 101
Space 3 CONNECT 3/4" CONDENSATE TO FAN COIL UNIT'S SECONDARY WASTE
106 HB 8
102 CONNECTION.
Electrical WC L 1 1"ø G
Yard 3/4"ø COND 4
1 1 TERMINATE 3/4" SECONDARY CONDENSATE 1/2" BELOW CEILING.
110
I Trash / 5 4" RD DN TO BELOW GRADE, SEE CIVIL FOR CONTINUATION.
Recycling 3/4"ø CW
Room 4 7
6 4" OD DN TO BELOW, TERMINATE FLUSH WITH FACE OF EXTERIOR WALL 6"
108 Unisex 3/4"ø COND ABOVE FINISHED GRADE.
3/4"ø CW
Toilet 5
105 Office 7 3/4" CW DN IN WALL ROUGH IN AND CONNECT.
6 104
2 8 1" GAS UP TO CEILING SPACE, CAPPED FOR FUTURE USE.
2
J HB
9 4" WASTE BELOW GRADE, SEE CIVIL FOR CONTINUATION.
3
1 5 10 4" FW, SEE CIVIL FOR CONTINUATION.
Janitor's 3 Security
7 Closet 2 7 HB 6 103 11 3/4" CW UP TO ROOF.
1/2"ø CW 109 3/4"ø SEC COND 1 3/4"ø SEC COND 12 SEE CIVIL FOR CONTINUATION.
JS 4
1

WH
1 1
FOR WORK TO BE DONE IN
1 1/2"ø CW 4"ø F AREA VIEW SHEET
10 1 2
P-402 P-402
HB
1
City of Torrance
Torrance Transit Park & Ride
12 Regional Terminal
465 Crenshaw Blvd.
Torrance, CA 90503

Torrance Transit
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

Regional
Terminal
CLIENT PROJECT #:B2013-15

Keyplan

Drawing Title Scale: 1/8" = 1'-0"

PLUMBING FLOOR
PLAN - WEST
BUILDING
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
Location
Drawing No.
LA
6/26/2017 3:30:12 PM

Project Manager

SJ
Project No.

P-201

N
13025
Date Plotted

06/26/2017

PLUMBING FLOOR PLAN - WEST BUILDING 1/8" = 1'-0" 1


14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
1. ALL VENTING SHALL HAVE A MIN. OF 10' CLEARANCE FROM ANY FORCED AIR INLET W/ A
MIN. OF 3' CLEARANCE ABOVE & A MIN OF 4' CLEARANCE FROM ANY PROPERTY LINE
EXCEPT A PUBLIC WAY PER CPC SEC. 906.
2. ROOF DRAIN & PIPES ARE BASED ON TABLE 11 @ 4" OF RAIN FALL PER HOUR W 1/8" PIPE
SLOPE. SEE DETAIL # 13 ON SHEET P-500

8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4

THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND


ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.

No. Distribution/Revision Date


30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
100% Cost Estimate 4.18.2014
C.1 C.2 C.3 C.4 C.5 C.6 C.7 City Submittal - Backcheck #1 05.05.2014
1 City Submittal 03.01.2017

275 W. Hospitality Lane Suite #100


San Bernardino, CA 92408
Phone: 909.890.3700
H Fax: 909.890.3770
email: info@designwesteng.com

DESIGN WEST ENGINEERING


MECHANICAL ELECTRICAL ENERGY CONSULTANTS
HB
HB
2
2

FESSIONA
PRO
CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER

GIN
V
REGI ST

SO
S TE
No. 33209

EER
N
4" VTR 4" RD & 4" OD DOWN TO BELOW
I 1
EXP. 9-30-2017
ME
AT C H A N I CA N

L
IA
ST
E O R
F CA L I F O
4" RD/OD
1,624 S.F. 1

2" VTR
J
RD/OD 4"
1 1 3,478 S.F. 1

City of Torrance
Torrance Transit Park & Ride
Regional Terminal
465 Crenshaw Blvd.
Torrance, CA 90503

Torrance Transit
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

Regional
Terminal
CLIENT PROJECT #:B2013-15

Keyplan

Drawing Title Scale: 1/8" = 1'-0"

PLUMBING ROOF
PLAN - WEST
BUILDING
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
Location
Drawing No.
LA
6/26/2017 3:30:13 PM

Project Manager

SJ
Project No.

P-202

N
13025
Date Plotted

06/26/2017

PLUMBING ROOF PLAN - WEST BUILDING 1/8" = 1'-0" 1


14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
1. ROUTE HOT WATER LOOP AS CLOSE AS POSSIBLE TO ALL FIXTURES.
2. ALL VENTING SHALL HAVE A MIN. OF 10' CLEARANCE FROM ANY FORCED AIR INLET W/
A MIN. OF 3' CLEARANCE ABOVE & A MIN OF 4' CLEARANCE FROM ANY PROPERTY LINE
EXCEPT A PUBLIC WAY PER CPC SEC. 906.

3. CONTRACTOR SHALL PATCH FLOORS, WALLS & CEILINGS TO MATCH NEW


CONSTRUCTION PER ARCHITECTS SPECIFICATIONS.

4. ROOF DRAIN & PIPES ARE BASED ON TABLE 11 @ 4" OF RAIN FALL PER HOUR W 1/8"
PIPE SLOPE. SEE DETAIL # 13 ON SHEET P-500

5. COORDINATE EXACT LOCATION OF S.O.V. BACKFLOW DEVICE, WATER METER & GAS
METER WITH ARCHITECT.

6. PRIOR TO CONSTRUCTION CONTRACTOR SHALL FIELD VERIFY FOR EXACT SIZE,


LOCATION & INVERT ELECATION OF EXISTING WASTE LINE & COORDINATE WITH
PLUMBING ENGINEER FOR ANY CHANGES NEEDED.

7. SHUT-OFF VALVES SHALL BE PROVIDED ON ALL MAIN BRANCHES, RUN TOO RISERS
8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
AND WHERE SHOWN ON DRAWING. LOCATE SHUT-OFF VALVES OVER T-BAR CEILING t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4
WHEN POSSILE. PROVIDE ACCESS PANELS WHEN SHUT-OFF VALVES ARE LOCATION
OVER HARD LID CEILINGS. 14 THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
P-500 OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
8. CONDENSATE PIPING SHALL BE INSULATED. SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.

4" COTG
3
1 No. Distribution/Revision Date
7 8.1 9 9.2 9.9 10 11 12 13 13.3 14 30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
100% Cost Estimate 4.18.2014
A
City Submittal - Backcheck #1 05.05.2014
1 City Submittal 03.01.2017
4" GW

C.9
C.10

Commercial
Space
150
4 4 3"ø G

275 W. Hospitality Lane Suite #100


2 1/2"ø TP (11) San Bernardino, CA 92408
3"ø RD 4"ø W Phone: 909.890.3700
Fax: 909.890.3770
2 email: info@designwesteng.com

B
Elevator DESIGN WEST ENGINEERING
Machine MECHANICAL ELECTRICAL ENERGY CONSULTANTS
Room
SEE CIVIL FOR 152
CONTINUATION 5

FC FESSIONA
PRO
Lobby E1-7 CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER

GIN
151

V
REGI ST

SO
S TE
3/4" COND 4" COTG No. 33209

EER
N
1 1 6" RD DN IN WALL & BELOW GRADE TO CURB FACE W/
3/4"ø SEC COND 1"ø HW 6" OD DN IN WALL TO DAYLIGHT EXP. 9-30-2017
4"ø W
ME
AT C H A N I CA N

L
IA
ST
D 2 3" RD DN IN WALL TO BELOW SLAB
E O R
F CA L I F O
Men's Exercise 3 3" OD DN IN WALL TO DAYLIGHT
Unisex Room
Women's Shower Men's Women's
Toilet Women's
Public Interview 164A Restroom Shower 167 4 3" RD & OD DN FROM ABOVE
159 1/2"ø G
Restroom Room Restroom 165A 9
2"ø HW 164
153 158 165 FC Electrical 5 4" CLEAN OUT TERMINATE FLUSH WITH GRADE
E1-3 Room
Open 6 TERMINATE 3/4" SECONDARY COND 1/2" BELOW CEILING
171
Offices 3/4"ø COND
157 Copy Room 7 3/4" CW & HW DN IN WALL TO FIXTURE
2"ø HW 160 6
8 1 1/2" VTR
3/4"ø SEC COND
3/4"ø COND
Visiting 2"ø W 9 1/2" GAS UP TO CEILING SPACE
Operators
E Restroom
Data Center
1"ø HW 2"ø W 170
6 154
FC 2"ø CW FC
1 1/2"ø CW 3/4"ø CW Pantry
E1-2 2"ø CW 3/4"ø CW 168 7 E1-6
Quiet Room 4 3
3/4"ø 1"ø CW
2 1/2"ø CW 163 P-401 P-401
SEC 3/4"ø COND 2 1/2"ø CW
COND FOR WORK TO BE DONE IN 3/4"ø COND
2"ø CW AREA VIEW SHEET 1 1/2"ø V
Men's
Operator's FC
Public FC JS
Restroom Dispatch Lounge E1-5
Vestibule E1-4 1
155 156 161 162
FC
S
E1-1 6
1 2"ø W
E.9
F
1

1 1 City of Torrance
1 8
Janitor Torrance Transit Park & Ride
2 P-401
Closet Regional Terminal
P-401 FOR WORK TO BE DONE IN 169 465 Crenshaw Blvd.
AREA VIEW SHEET
SEE CIVIL FOR Torrance, CA 90503
SEE CIVIL FOR SEE CIVIL FOR CONTINUATION
CONTINUATION CONTINUATION

Torrance Transit
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

Regional
Terminal
CLIENT PROJECT #:B2013-15

Keyplan

Drawing Title Scale: 1/8" = 1'-0"

FIRST FLOOR
PLUMBING FLOOR
PLAN - EAST
BUILDING
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
Location
Drawing No.
LA
6/26/2017 3:30:15 PM

Project Manager

SJ
Project No.

P-301

N
13025
Date Plotted

06/26/2017

FIRST FLOOR PLUMBING FLOOR PLAN - EAST BUILDING 1/8" = 1'-0" 1


14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
1. ROUTE HOT WATER LOOP AS CLOSE AS POSSIBLE TO ALL FIXTURES.

2. ALL VENTING SHALL HAVE A MIN. OF 10' CLEARANCE FROM ANY FORCED AIR INLET W/
A MIN. OF 3' CLEARANCE ABOVE & A MIN OF 4' CLEARANCE FROM ANY PROPERTY LINE
EXCEPT A PUBLIC WAY PER CPC SEC. 906.

3. CONTRACTOR SHALL PATCH FLOORS, WALLS & CEILINGS TO MATCH NEW


CONSTRUCTION PER ARCHITECTS SPECIFICATIONS.

4. ROOF DRAIN & PIPES ARE BASED ON TABLE 11 @ 4" OF RAIN FALL PER HOUR W 1/8"
PIPE SLOPE. SEE DETAIL # 13 ON SHEET P-500

5. COORDINATE EXACT LOCATION OF S.O.V. BACKFLOW DEVICE, WATER METER & GAS
METER WITH ARCHITECT.

6. PRIOR TO CONSTRUCTION CONTRACTOR SHALL FIELD VERIFY FOR EXACT SIZE,


LOCATION & INVERT ELECATION OF EXISTING WASTE LINE & COORDINATE WITH
PLUMBING ENGINEER FOR ANY CHANGES NEEDED.

7. SHUT-OFF VALVES SHALL BE PROVIDED ON ALL MAIN BRANCHES, RUN TOO RISERS
8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
AND WHERE SHOWN ON DRAWING. LOCATE SHUT-OFF VALVES OVER T-BAR CEILING t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4
WHEN POSSILE. PROVIDE ACCESS PANELS WHEN SHUT-OFF VALVES ARE LOCATION
OVER HARD LID CEILINGS. THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
8. CONDENSATE PIPING SHALL BE INSULATED. OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.

No. Distribution/Revision Date


30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
100% Cost Estimate 4.18.2014
City Submittal - Backcheck #1 05.05.2014
1 City Submittal 03.01.2017

7 8.1 9 9.2 9.9 10 11 12 13 13.3 14

275 W. Hospitality Lane Suite #100


San Bernardino, CA 92408
Phone: 909.890.3700
Fax: 909.890.3770
email: info@designwesteng.com

A
DESIGN WEST ENGINEERING
MECHANICAL ELECTRICAL ENERGY CONSULTANTS

FESSIONA
PRO
CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER

GIN
V
REGI ST

SO
S TE
No. 33209

EER
N
1 CONNECT 3/4" CONDENSATE TO FAN COIL IN DIRECT WASTE CONNECTION.
EXP. 9-30-2017
2 CONNECT 3/4" CONDENSATE TO FAN COIL UNIT'S SECONDARY WASTE CONNECTION. ME
AT C H A N I CA N

L
IA
ST
3 1 1/2" CW & 1" HW CAPPED FOR FUTURE E O R
F CA L I F O
4 4" RD & 4" OD DN TO BELOW

DF 5 4"RD & 4" OD DN FROM ABOVE


RD/OD 1
RD/OD 6 4" W CAPPED FOR FUTURE
1
1 7
7 4" W DN TO BELOW
B
8 1 1/2" CW UP FROM BELOW TO CEILING SPACE
6 FC
3
E2-3

3/4"ø CW
2
Exterior
1 1/2"ø CW 3/4" SEC COND
Patio
211
1"ø HW
3/4" COND
Second 8
Floor Lobby 4"ø OD
5 5
201 1 4"ø RD

D
3/4" SEC COND

FC Janitor
Closet 5 FC
E2-1 2 FC
207 E2-4
E2-5 1/2"ø G
3/4"ø COND 3/4"ø COND

1
3/4" SEC COND 3/4" SEC COND
3/4" COND 4"ø OD
1 2 City of Torrance
Hallway Women's Men's 1 2 4"ø RD
201A Restroom Restroom Torrance Transit Park & Ride
IT Closet
205 204 208
Regional Terminal
FOR WORK TO BE DONE IN E 465 Crenshaw Blvd.
AREA VIEW SHEETS Torrance, CA 90503
4 3
Conference 3/4" SEC
202 Storage P-402 P-402
COND 3/4"ø COND Training /
209
4"ø OD 2 1
Simulator
Multipurpose
Room Torrance Transit
203 210
4"ø RD
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

FC
E2-2

E.9
Regional
Storage
203A
F
Terminal
CLIENT PROJECT #:B2013-15

4 4 Keyplan

Drawing Title Scale: 1/8" = 1'-0"

SECOND FLOOR
PLUMBING FLOOR
PLAN - EAST
BUILDING
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
Location
Drawing No.
LA
6/26/2017 3:30:16 PM

Project Manager

SJ
Project No.

P-302

N
13025
Date Plotted

06/26/2017

SECOND FLOOR PLUMBING FLOOR PLAN - EAST BUILDING 1/8" = 1'-0" 1


14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
1. ALL VENTING SHALL HAVE A MIN OF 10' CLEARANCE FROM ANY FORCED AIR
INLET W/ A MIN. OF 3' CLEARANCE ABOVE & A MIN OF 4' CLEARANCE FROM ANY
PROPERTY LINE EXCEPT A PUBLIC WAY PER CPC SEC. 906.

2. ROOF DRAINS & PIPES ARE BASED ON TABLE 11 @ 4" OF RAIN FALL PER HOUR W/
1/8" PIPE SLOPE. SEE DETAIL # 13 ON SHEET P-500.

8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4

THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND


ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.

No. Distribution/Revision Date


30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
100% Cost Estimate 4.18.2014
City Submittal - Backcheck #1 05.05.2014
7 8.1 9 9.2 9.9 10 11 12 13 13.3 14 1 City Submittal 03.01.2017

275 W. Hospitality Lane Suite #100


A San Bernardino, CA 92408
Phone: 909.890.3700
Fax: 909.890.3770
email: info@designwesteng.com

DESIGN WEST ENGINEERING


MECHANICAL ELECTRICAL ENERGY CONSULTANTS
C.11
C.12

FESSIONA
PRO
CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER

GIN
V
REGI ST

SO
S TE
No. 33209

EER
N
1 4" VENT THRU ROOF. EXP. 9-30-2017
ME
AT C H A N I CA N

L
4" RD/OD DOWN IN WALL TO BELOW

IA
ST
2
E O R
F CA L I F O

RD/OD 4"
1 1,348 S.F. RD/OD 4"
1 1,126 S.F.

D
1
4" VTR
4" VTR

4" RD/OD
1,330 S.F. 1
1

City of Torrance
Torrance Transit Park & Ride
Regional Terminal
465 Crenshaw Blvd.
Torrance, CA 90503

Torrance Transit
E.9 Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

F
Regional
Terminal
CLIENT PROJECT #:B2013-15

Keyplan

Drawing Title Scale: 1/8" = 1'-0"

PLUMBING ROOF
PLAN - EAST
BUILDING
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
Location
Drawing No.
LA
6/26/2017 3:30:17 PM

Project Manager

SJ
Project No.

P-303

N
13025
Date Plotted

06/26/2017

PLUMBING ROOF PLAN - EAST BUILDING 1/8" = 1'-0" 1


14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
1. ROUTE HOT WATER LOOP AS CLOSE POSSIBLE TO ALL FIXTURES.
8.1 9 2. ALL VENTING SHALL HAVE A MIN. OF 10' CLEARANCE FROM ANY FORCED AIR INLET
W/ A MIN. OF 3' CLEARANCE ABOVE & A MIN. OF 4' CLEARANCE FROM ANY
PROPERTY LINE EXCEPT A PUBLIC WAY PER CPC SEC. 906.
L
2 1 3. SHUT-OFF VALVES SHALL BE PROVIDED ON ALL MAIN BRACHES, RUNS TOO
C.D 2 (TYP OF 4) RISERS, AND WHERE SHOWN ON DRAWING, LOCATE SHUT-OFF VALVES OVER T-
3/4"ø CW BAR CEILING WHEN POSSIBLE PROVIDE ACCESS PANELS WHEN SHUT-OFF
3/4"ø HW VALVES ARE LOCATED OVER HAND LID CEILINGS

D 4. CONDENSATE PIPING SHALL BE INSULATED.

FD
1

Women's 1 1/4"ø HW
1 1/4"ø HW
Public
8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
Restroom t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4
153
9.9 10 11 244 SF THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
WC 2"ø CW OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
3
4 SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
WHA TP WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
FD (TYP OF 7) DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
2 1 1 WC SH 1/2" TP ACCEPTANCE OF THESE RESTRICTIONS.
1
L 1 1/2"ø CW 1 1 3
3/4"ø HW (TYP OF 2)
1 (TYP OF 6)
1 1/2"ø CW
No. Distribution/Revision Date
30% Design Review/Cost Estimate 8.15.2013
FD Men's 3/4"ø HW
TP 3/4"ø CW SH L 65% Construction Documents 11.15.2013
1 Shower
1 1 3 City Submittal 12.17.2013
164A TP
41 SF 2 100% Cost Estimate 4.18.2014
1 1"ø HW 1 1/2"ø TP (9) 2"ø TP (9) City Submittal - Backcheck #1 05.05.2014
3/4"ø HW 1 WHA 1
1/2"ø TP FD
1/2"ø TP (TYP) FD C.E
1 1/2"ø CW 1 1 City Submittal 03.01.2017
1"ø HW 2 TP WHA
1 1 2 1/2"ø CW 2 Owner Revisions 06.23.2017
1 1 1 1/2"ø CW
Unisex 3/4"ø CW
9 1"ø HW
Women's E
2 Toilet Men's Shower Visiting
1/2"ø TP TP 4
159 Restroom 2"ø CW Operators
165A U 1
64 SF
164 41 SF C.F Restroom
214 SF
2 3
154
(TYP OF 2) 1 1/2"ø CW 81 SF
1"ø CW U 1 1/2"ø CW
3/4"ø CW Women's
1 3/4"ø CW
Restroom
165
3/4"ø CW 219 SF
2 1/2"ø CW

2"ø CW 2"ø CW
Copy Room 3/4"ø HW 1"ø HW 1"ø HW 275 W. Hospitality Lane Suite #100
San Bernardino, CA 92408
1"ø HW 160
134 SF
1 1/2"ø CW Phone: 909.890.3700
C.G Fax: 909.890.3770

WHA email: info@designwesteng.com


1
E
L
1 2
3/4"ø HW Men's 2 1/2"ø CW DESIGN WEST ENGINEERING
2 2 1 Public MECHANICAL ELECTRICAL ENERGY CONSULTANTS
(TYP OF 4) Restroom
155 1"ø HW 1/2" TP
266 SF
C.H FD
2 1/2"ø CW FESSIONA
PRO
1
CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER

GIN
V
REGI ST

SO
S TE
No. 33209

EER
N
1 3/4" CW DN IN WALL ROUGH-IN AND CONNECT. EXP. 9-30-2017
E.9 ME
3/4" HW DN IN WALL ROUGH -IN AND CONNECT.
AT C H A N I CA N

L
2

IA
ST
E O R
F 3 2" CW DN IN WALL ROUGH-IN AND CONNECT. F CA L I F O
3/4"ø CW
3/4"ø HW 2 1 4 1-1/2" CW DN IN WALL ROUGH-IN AND CONNECT.

5 2" VENT UP INTO CEILING SPACE.

6 2" WASTE DN BELOW GRADE

7 4" WASTE DN BELOW GRADE

N
8 3/4" CONDENSATE DN IN WALL CONNECT TO TAILPIECE OF LAVATORY.

9 3/4" CW UP TO ABOVE.

ENLARGED SECTION 2 EAST BUILDING FIRST FLOOR DOMESTIC WATER & GAS 1/4" = 1'-0" 3 ENLARGED SECTION 1 EAST BUILDING FIRST FLOOR DOMESTIC WATER & GAS 1/4" = 1'-0" 1 10

11
4" RD & 4" OD DN FROM ROOF INTO CEILING SPACE.

2" VENT UP TO ABOVE.

12 TERMINATE 3/4" CONDENSATE 1/2" BELOW CEILING

13 3" VENT UP TO ABOVE

14 3/4" COND DN IN WALL TO TAILPIECE OF FIXTURE. SEE DETAIL #13 ON


SHEET P-500
8.1 9

L
2 2"ø W
C.D 5
(TYP OF 4) 1 1/2"ø V 3/4"ø SEC COND

D
City of Torrance
6 Torrance Transit Park & Ride
4"ø W Regional Terminal
12 465 Crenshaw Blvd.
WCO ABOVE FIXTURE, SEE FD Torrance, CA 90503
DETAIL (TYP.)
3 1
1 P-500 Women's (TYP OF 2)
Public 4"ø W

9.9 10 11
Restroom
153
Torrance Transit
244 SF
WC
3
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

1 1/2"ø V
WC (TYP OF 7) 7

1 1/2"ø V
1 2"ø V
Regional
(TYP OF 6) 2"ø V 4"ø W
14 L

L
7 3
3"ø V
Terminal
1
4"ø W FD CLIENT PROJECT #:B2013-15
2"ø W 2"ø W
1 12 Keyplan
4"ø W C.E 4"ø W 2"ø V

FD Men's 2"ø W 2"ø V


4"ø W 4"ø W 2"ø W 4"ø W
Shower 2"ø V 3/4"ø COND
1 2"ø W E Visiting A
164A 1 1/2"ø V FD
41 SF
Operators 8
Unisex 1 Restroom 4"ø W
4"ø W Women's
2 Toilet FD
Shower
C.F 154 B
159 1 4"ø W 81 SF

1 1/2"ø V 165A
64 SF
2"ø V 41 SF 1 1/2"ø V 2"ø V C
11 2"ø V
2"ø W 5
4"ø W
Men's Women's D
Restroom 2"ø W Restroom
164 4"ø W 165 2"ø V E
214 SF 219 SF
3/4"ø COND 2"ø V

U 6
Copy Room 1 1/2"ø V
1 12 C.G
160 U
134 SF
2
13 1 1/2"ø V 1 1/2"ø V
(TYP OF 2)

E Men's
1 1/2"ø V 2"ø W Public Scale: 1/4" = 1'-0"
2"ø W WCO ABOVE FIXTURE, 3/4"ø COND Restroom Drawing Title
L SEE DETAIL (TYP.)
3 8 8 155
C.H
2
(TYP OF 4)
1
P-500 266 SF

2"ø W
PLUMBING
2"ø W ENLARGED PLANS
E.9
F
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
6 1 1/2"ø V Location
Drawing No.
LA
6/26/2017 3:30:20 PM

Project Manager

SJ
Project No.

P-401

N
13025
Date Plotted

06/26/2017

ENLARGED SECTION 2 EAST BUILDING FIRST FLOOR WASTE & VENTS 1/4" = 1'-0" 4 ENLARGED SECTION 1 EAST BUILDING FIRST FLOOR WASTE & VENTS 1/4" = 1'-0" 2
14-037
F R A N K R. W E B B
GENERAL NOTES A R C H I T E C T S
w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n

1. CONDENSATE PIPING SHALL BE INSULATED.

2. ROUTE HOT WATE LOOP AS CLOSE AS POSSIBLE TO ALL FIXTURES.

3. ALL VENTING SHALL HAVE A MIN. OF 10' CLEARANCE FROM ANY FORCED AIR INLET W/
A MIN. OF 3' CLEARANCE ABOVE & A MIN. OF 4' CLEARANCE FROM ANY PROPERTY LINE
EXCEPT A PUBLIC WAY PER CPC SEC. 906.

4. SHUT-OFF VALVES SHALL BE PROVIDED ON ALL MAIN BRACHES, RUNS TOO RISERS
AND WHERE SHOWN ON DRAWING, LOCATE SHUT-OFF VALVES OVER T-BAR CEILING
WHEN POSSIBLE. PROVIDE ACCESS PANELS WHEN SHUT-OFF VALVES ARE LOCATED
OVER HARD LID CEILINGS.

8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
9 9.2 9.9 10 C.3 t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4

THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND


ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
ACCEPTANCE OF THESE RESTRICTIONS.

D
WH No. Distribution/Revision Date
1 1/4"ø HW 2 30% Design Review/Cost Estimate 8.15.2013
DF 16
65% Construction Documents 11.15.2013
L 1 1 1/4"ø HW WHA
3/4"ø HW L City Submittal 12.17.2013
2 1
1 100% Cost Estimate 4.18.2014
(TYP OF 4) 3 City Submittal - Backcheck #1 05.05.2014
15 TP
JS 2
9 1 1 City Submittal 03.01.2017
U 1 1
I 2 Owner Revisions 06.23.2017
1 3/4"ø CW
1 1/4"ø HW
WC
3/4"ø CW
WHA 1
1/2"ø G
1 C.J
10 14
11

12 1 1/2"ø CW
2"ø HW
1/2" TP 3/4"ø HW 3/4"ø CW
3/4"ø CW 1/2"ø TP

CP
1
TP FD
275 W. Hospitality Lane Suite #100
1 1 San Bernardino, CA 92408
3/4"ø HW
2 Phone: 909.890.3700
Fax: 909.890.3770
1 1/2"ø CW
1/2" TP J email: info@designwesteng.com
E
3/4"ø CW
3/4"ø CW
WC
2"ø CW
2
3/4"ø HW DESIGN WEST ENGINEERING
1 MECHANICAL ELECTRICAL ENERGY CONSULTANTS
13
(TYP OF 5) TP 3 2"ø CW
1 FD
3/4"ø HW
3 FESSIONA
2 PRO
JS CONSTRUCTION NOTES ED
EN
M. J OH
L

EN
N

ER

GIN
V
1

REGI ST

SO
S TE
No. 33209

EER
N
1/2"ø CW 1 1-1/2" CW DN IN WALL TO FULL SIZE HEADER WITH SOV IN RISER WITH ACCESS EXP. 9-30-2017
PANEL ROUGH-IN AND CONNECT. ME
AT C H A N I CA N

L
3/4"ø HW

IA
ST
K 2 3/4" HW DN IN WALL WITH SOV IN RISER ROUGH-IN AND CONNECT. E O R
F CA L I F O
C.K WH
1 4"ø F 3 3/4" CW DN IN WALL ROUGH-IN AND CONNECT.
1 1/2"ø CW
3/4"ø CW ET 4 2" VTR.
1
5 3/4" CONDENSATE DOWN IN WALL, CONNECT TO TAILPIECE OF LAVATORY.

6 1-1/2" VENT BELOW GRADE.

N
7 1-1/2" VENT UP IN WALL.

8 1-1/2" VTR.

9 1-1/4" HW DN IN WALL ROUGH-IN AND CONNECT.

ENLARGED EAST BUILDING SECOND FLOOR DOMESTIC WATER & GAS 1/4" = 1'-0" 3 ENLARGED WEST BUILDING DOMESTIC WATER & GAS 1/4" = 1'-0" 1 10 1-1/4 HW DN TO BELOW.

11 3/4" CW UP FROM BELOW.

12 3/4" HW UP FROM BELOW.

13 2" CW UP FROM BELOW.

14 3/4" CW UP FROM BELOW, ROUGH-IN AND CONNECT.

15 1-1/4" HW UP TO CEILING SPACE.

16 3/4" GAS DN FROM CEILING SPACE.

17 1-1/2" VENT UP INTO CEILING SPACE, 2" WASTE DN BELOW GRADE

18 4" VTR

19 3" VENT UP FROM BELOW

C.3 1-1/2' VENT UP TO CEILING SPACE. City of Torrance


9 9.2 9.9 10 20
Torrance Transit Park & Ride
21 TERMINATE 3/4" COND 1/2" BELOW CEILING Regional Terminal
465 Crenshaw Blvd.
Torrance, CA 90503

3/4"ø COND
D
Torrance Transit
4"ø W

DF
3/4"ø COND
WH 4"ø W 2"ø W
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

18 1 U 2
L
2
21
1
JS
3/4"ø COND
Regional
(TYP OF 4) 1 5

5
17 2"ø W 2"ø W 21 1 1/2"ø V I
2"ø V
Terminal
2"ø W 4"ø W
1 1/2"ø V 4 CLIENT PROJECT #:B2013-15
4"ø W
5
C.J Keyplan
3"ø V 1 1/2"ø V WCO ABOVE FIXTURE,
3/4"ø COND SEE DETAIL 3 (TYP.)
6 L
A
P-500 1
2"ø W
6
20 2"ø W B
WC 2
21 3"ø W
1 C
4"ø W
8 8
3"ø W
19 2"ø W D

2"ø V J E
E 3"ø W

1 1/2"ø V 7
8
WCO ABOVE FIXTURE,
WC SEE DETAIL (TYP.)
3
1
P-500
(TYP OF 5) 1
6

JS FD
1 3
Drawing Title Scale: 1/4" = 1'-0"

K
PLUMBING
C.K
ENLARGED PLANS
CONTINUED
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
Location
Drawing No.
LA
6/26/2017 3:30:23 PM

Project Manager

SJ
Project No.

P-402

N
13025
Date Plotted

06/26/2017

ENLARGED EAST BUILDING SECOND FLOOR WASTE & VENTS 1/4" = 1'-0" 4 ENLARGED WEST BUILDING WASTE & VENTS 1/4" = 1'-0" 2
14-037
F R A N K R. W E B B
1/2" CW FOR CONNECTION TO
TRAP STRUCTURE SEE
SUPPLY 1 A R C H I T E C T S
PRIMER THREADED HANGAR
ROD. FOR SIZE AND w w w . t e a m f w a . c o m L o s A n g e l e s | F u l l e r t o n
VENT FULL SIZE OF -
TP SPACING SEE
COND. DRAIN. BALL VALVE 2
1/2" CW (TYP) 1
-
PRECISION PLUMBING PRODUCTS
FC UNIT, SEE SECONDARY PRIME-RITE TRAP PRIMER VALVE
BALL VALVE
MECH DWGS CONDENSATE PAN MODEL #PR-500 FD
TERMINATE SECONDARY 2" MIN. CONDENSATE DRAIN FROM FC ADD VERTICAL ANGLE TYP. I-BEAM - SEE
1
CONDENSATE LINE W/ UNIT. SEE FLOOR PLANS FOR STIFFNER IF LENGTH IS STRUCTURAL FOR SIZE
REFER TO PLANS GREATER THAN MAX. "B - LINE" B3050 BEAM
ELBOW DN ROUTING & SIZES. FOR SIZE AND LOCATION AND LOCATION
LENGTH SHOWN ON PIPE CLAMP
SUPPORT SCHEDLE
ACCESS
CEILING FLOOR PANEL
ESCUTCHEON 1/2" CW NUT & WASHER
S L TOP & BOTTOM
OR TRANSVERSE ANGLE BRACE.
1 1
ALTERNATIVE SIDES EVERY BRACE
ESCUTCHEON DISTRIBUTION UNIT
CONDENSATE LINE, WHERE REQUIRED
ESCUTCHEON
SLOPE TO DRAIN. "B-LINE" - B3690 8 6 0 7 V e n i c e B o u l e v a r d L o s A n g e l e s , C A 9 0 0 3 4
ADJUSTABLE "J" HANGAR t e l : 3 1 0 . 5 5 9 . 4 7 1 7 f a x : 3 1 0 . 5 5 9 . 9 1 7 4
S L TO FLOOR SINK OR 3" 1/2"ø MACH. BOLT AT "B - LINE" B -321 1/2"ø
OR FLOOR DRAIN TRAP CENTERLINE OF CHANNEL THREADED EYE ROD.
- - THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
LENGTH AS REQUIRED ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE PROPERTY
OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED, DISCLOSED TO OTHERS,
FLOOR DRAIN TRAP PRIMER PIPING. SEE PLANS FOR SIZE OR USED IN CONNECTION WITH ANY WORK OR PROJECT OTHER THAN THE
SPECIFIED PROJECT FOR WHICH THEY HAVE BEEN PREPARED AND DEVELOPED
COND. CONN. TO TAIL PCS. WITH SLIP DISTRIBUTION CHART AND LOCATION WITHOUT THE WRITTEN CONSENT OF THE ARCHITECT. VISUAL CONTACT WITH THESE
JOINT FITTINGS BELOW SINK. SEE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF
COND. SLOPE TO DRAIN MAX. WATER ACCEPTANCE OF THESE RESTRICTIONS.
FLOOR PLANS FOR SIZES
NO. OF DISTRIBUTION DEL. ON 15 USE STAND DISTRIBUTION "B - LINE" B - 321 1/2"ø
DRAINS UNIT MODEL SEC. PRESS. PIPE STYLE UNIT IS 1/2"ø THREADED HANGAR ROD COUPLING
DROP. ROD. LENGTH AS REQUIRED
1 N/A 2 OZ. STRAIGHT NOT REQUIRED No. Distribution/Revision Date
INSULATION WHERE "B-LINE" B3162 PIPE SADDLE 30% Design Review/Cost Estimate 8.15.2013
COND. CONN. TO TAIL PCS WITH SLIP 2 DU-2 2 OZ. STRAIGHT 2 OPENING APPILES - SEE
JOINT FITTING BELOW SINK. SEE FLOOR 65% Construction Documents 11.15.2013
NOTE: APECIFICATIONS
PLANS FOR SIZES 3 DU-3 5 OZ. STRAIGHT 3 OPENING City Submittal 12.17.2013
ACCESS PANEL SHALL NOT BE INSTALLED
BEHIND GRAB BARS. 100% Cost Estimate 4.18.2014
4 DU-4 5 OZ. STRAIGHT 4 OPENING City Submittal - Backcheck #1 05.05.2014
1 City Submittal 03.01.2017
2 Owner Revisions 06.23.2017

CONDENSATE TO FC/LAV SINK 17 CONDENSATE TO LAV 13 TRAP PRIMER 9 PIPE SUPPORT 5 CONNECTION TO STRUCTURE 1
2 MAXIMUM SPAN 2 1 2
PIPE SIZE BETWEEN SUPPORT HANGER ROD MAX. LENGTH LONGITUDINAL VERTICAL TRANSVERSE BOLT
IN INCHES HANGERS O.C. DIAMETER SIZE FOR RODS ANGLE BRACE HANGER ANGLE ANGLE BRACE SIZE
(STIFFNER)
HORIZ. VERT.
COPPER TUBE & PIPE
EXTERIOR CONCRETE WALL _1 & 3_ 1-1/2 x 1-1/2 x 18 1-1/2 x 1-1/2 x 18
2 4 6'-0" 10'-0" 3/8" 37" 1 x 1 x 18ga 3/8"
ga @ 80'-0" O.C. ga @ 40'-0" O.C.
1 THRU 1/2 1-1/2 x 1-1/2 x 18 1-1/2 x 1-1/2 x 18 275 W. Hospitality Lane Suite #100
6'-0" 10'-0" 3/8" 37" 1 x 1 x 18ga 3/8"
CAULK AND SEAL WATERTIGHT TYPICAL PIPE. SEE RD OD ga @ 80'-0" O.C. ga @ 40'-0" O.C. San Bernardino, CA 92408
FURRED WALL ROOF SUMP
(WHERE REQUIRED) (TYP BOTH SIDES) PLANS FOR SIZE AND 1 1 1-1/2 x 1-1/2 x 18 2-1/2 x 2-1/2 x 16 Phone: 909.890.3700
RECEIVER (TYP) 2 10'-0" 10'-0" 3/8" 37" 1 x 1 x 18ga 3/8"
OVERFLOW DRAIN PIPE LOCATION ga @ 80'-0" O.C. ga @ 40'-0" O.C. Fax: 909.890.3770
REFERENCE PLUMBING PLANS STEEL PIPE FOR GAS
FOR SIZES & LOCATIONS email: info@designwesteng.com
GALV MTL. 2" WATER DAM _1 & 3_ 1-1/2 x 1-1/2 x 18 1-1/2 x 1-1/2 x 18
2 4 6'-0" 6'-0" 3/8" 37" 1 x 1 x 18ga 3/8"
PIPE SUPPORT ga @ 80'-0" O.C. ga @ 40'-0" O.C.
MIFAB R1940 DOWNSPOUT NOZZLE
MOUNT OVERFLOW DRAIN
1 8'-0" 8'-0" 3/8" 37"
1-1/2 x 1-1/2 x 18
ga @ 80'-0" O.C.
1 x 1 x 18ga
1-1/2 x 1-1/2 x 18
ga @ 40'-0" O.C.
3/8" DESIGN WEST ENGINEERING
MECHANICAL ELECTRICAL ENERGY CONSULTANTS
6" ABOVE ROOF DRAIN 1- thru 2 2-1/2 x 2-1/2 x 16 2-1/2 x 2-1/2 x 16
10'-0" 10'-0" 3/8" 37" 1 x 1 x 18ga 3/8"
ga @ 80'-0" O.C. ga @ 40'-0" O.C.
FINISH GRADE OR
UNDERDECK SEE SCHEDULE 40 PVC & ABS DWV 3
CONCRETE WALKWAY
FINISH FLOOR CLAMP (TYP) ARCHITECTURAL
DWGS. FOR ROOF _1 & 3_ 1-1/2 x 1-1/2 x 18 1-1/2 x 1-1/2 x 18
4'-0" 10'-0" 3/8" 37" 1 x 1 x 18ga 3/8" FESSIONA
ROOF DRAIN PIPE CONSTRUCTION
2 4 ga @ 80'-0" O.C. ga @ 40'-0" O.C. PRO L
ED M. J OH
EN

EN
REFERENCE PLUMBING 1-1/2 x 1-1/2 x 18 1-1/2 x 1-1/2 x 18 N

ER
1 thru 2 4'-0" 10'-0" 3/8" 37" 1 x 1 x 18ga 3/8"

GIN
SLOPE

V
REGI ST
PLANS FOR SIZES & ga @ 80'-0" O.C. ga @ 40'-0" O.C.

SO
S TE
FOR PIPING CONTINUATION
No. 33209

EER
N
LOCATIONS SEE PLUMBING FLOOR CAST IRON HUBLESS (NO HUB)
PLAN (TYP) EXP. 9-30-2017
1-1/2 x 1-1/2 x 18 1-1/2 x 1-1/2 x 18
1- & 2 A 15'-0" 3/8" 37" 1 x 1 x 18ga 3/8" ME
ga @ 80'-0" O.C. ga @ 40'-0" O.C.
AT C H A N I CA N

L
IA
ST
REFERENCE CIVIL PLANS CONCRETE FLOOR DECK ABS OR PVC PIPE E O R
FOR CONTINUATION SEE STRUCTURAL DWGS, SLEEVE
3 thru 6 A REFER TO SMACNA GUIDELINES IN SCHEDULE BELOW F CA L I F O
SUPPORT EVERY JOINT. SUPPORT SHALL BE WITHIN 18 INCHES OF JOINT ON BOTH SIDES. (SUPPORT ALSO REQUIRED AT EACH
A HORIZONTAL JOINT CONNECTION.)

STRUCTURAL ALL PIPING 2-1/2" AND LARGER PER THE FOLLOWING SMACNA GUIDELINES
CONC. FOOTING 2-1/2 x 2-1/2 x 16 2-1/2 x 2-1/2 x 16
2-1/2 10'-0" 10'-0" 1/2" 25" 2 x 2 x 16ga 3/8"
ga @ 80'-0" O.C. ga @ 40'-0" O.C.
2-1/2 x 2-1/2 x 16 2-1/2 x 2-1/2 x 16
3 10'-0" 10'-0" 1/2" 25" 2 x 2 x 16ga 3/8"
ga @ 80'-0" O.C. ga @ 40'-0" O.C.
2-1/2 x 2-1/2 x 16 2-1/2 x 2-1/2 x 16
4 10'-0" 10'-0" 5/8" 31" 2 x 2 x 16ga 1/2"
ga @ 80'-0" O.C. ga @ 40'-0" O.C.
2-1/2 x 2-1/2 x 16 2-1/2 x 2-1/2 x 16
5 10'-0" 10'-0" 5/8" 31" 2 x 2 x 16ga 1/2"
ga @ 80'-0" O.C. ga @ 40'-0" O.C.
2-1/2 x 2-1/2 x 16 2-1/2 x 2-1/2 x 16
6 10'-0" 10'-0" 5/8" 37" 2 x 2 x 16ga 1/2"
ROOF DRAIN 14 PIPE PENETRATION THRU FLOOR 10 ROOF & OVERFLOW DRAIN 6 ga @ 40'-0" O.C. ga @ 40'-0" O.C.

NOTES:
1 VERTICAL ANGLE ONLY REQUIRED WHEN ROD MAXIMUM LENGTH IS EXCEEDED.
2 BRACING MAY BE OMITTED WHERE TOP OF PIPE IS 12" OR LESS FROM BOTTOM OF HANGER SUPPORT CONNECTED TO STRUCTURE
3 ALLOW FOR EXPANSION EVERY 30'-0".
STAINLESS STEEL INSTALL PER CPC 313.0
ACCESS PANEL 'STORMTITE' VANDAL PROOF
WATER HAMMER ARRESTOR

"STORMTITE" SEAMLESS
PIPE CAP
PIPING SUPPORT SCHEDULE 2
LEAD ROOF FLASHING
ASSEMBLY.
NOTES:
CAULK AND SEAL WATERTIGHT TYPICAL PIPE. 1. INSTALL PER CPC (SEC. 707.0 & 719.0)
(TYP BOTH SIDES) 2. CLEAN OUTS SHALL BE INSTALLED IN WALL ABOVE WATER CLOSETS, 1
SEE PLANS FOR WALL
SEE ARCH. URINALS AND LAVATORIES
SIZE & LOCATION.
BALL VALVE DWGS FOR ROOF City of Torrance
2 1/2" CONSTRUCTION VENT Torrance Transit Park & Ride
ROOFING OVER
BASE 7" Regional Terminal
5" 465 Crenshaw Blvd.
REFER TO PLANS FOR WCO
SIZE & LOCATION Torrance, CA 90503
ABS OR PVC
PIPE SLEEVE
COVER PLATE

PERMASEAL
TYP.
Torrance Transit
CONCRETE OR BLOCK WALL WASTE
PIPE SIZING AND SELECTION TABLE
SEE STRUCTURAL DWGS.
8"
COVER PLATE
Park and Ride
C:\Users\acloud\Documents\14-037 Torrance Transit Center MEP_Central_acloud.rvt

PPP SIZE FIXTURE UNITS CROSS REF. PDI STEEL REINFORCING SIDEWALK FINISH FLOOR
BOOT TYP.
1/2" 1-11 A TYPICAL PIPE
SEE PLANS FOR
COTG
Regional
3/4" 12-32 B
SIZE & LOCATION
1" 33-60 C Terminal
1-1/4" 61-113 D NOTE: OUTSIDE INSIDE
PIPE CLAMP (TYP)
ACCESS PANEL SHALL NOT BE INSTALLED PIPE PENETRATION DETAIL CLIENT PROJECT #:B2013-15
1-1/2" 114-154 E 1% SLOPE WASTE 2% SLOPE
BEHIND GRAB BARS.
Keyplan
2" 155-330 F

A
WATER HAMMER ARRESTOR 15 PIPE THRU WALL 11 VENT THRU ROOF 7 CLEAN OUT 3
B
VACUUM RELIEF VALVE CHECK VALVE (TYP)
INSTALL PER LOCAL CODES C
CW
HW
D
1.5 GAL. THERMAL
CW TO BUILDING EXPANSION TANK AMERI-VENT TYPE "B" UL
APPROVED FLUE CAP. E
AQUA STAT SECURE WITH #3 SHEET
HB 3/4"
WALL MOUNTED SILICONE SEALER HWR METAL SCREWS
6 LB. SHEET LEAD FLASHING BALL VALVE (TYP)
1 HOSE BIBB 18 GA. G.I. WEATHER HOOD
IN RECESSED BOX RIVIT & SOLDER TO VENT PIPE
CP
ROOFING OVER BASE
1
HOSE CLAMP
ASME RATED PRESS.
EXTERIOR WALL RELIEF VALVE ROOFING OVER BASE
18" MIN.
SECURE W/H TO WALL
WH POP-OFF DRAIN Scale: 1 : 1
WITH 1" WIDE - MIN. 20 Drawing Title
GA. SHT. MTL. STRAP & 1 LINE FULL SIZE OF
(2) 1/4"∅ LAG BOLTS UNIT CONNECTION
CW MAIN. SEE PLANS
FOR SIZE & LOCATION
SEE ARCHITECTURAL
EACH END. PER CPC
SEC. 508.0 - 508.2
PLUMBING DETAILS
DWGS FOR ROOF GALV. SHT. MTL.
8" MIN. "SMITTY" PAN
CONSTRUCTION
SIDE WALK OR GRADE SEE ARCHITECTURAL
18 GA. G.I. FLASHING SECURE DWGS FOR ROOF
TO ROOF WITH #10 SHEET 8" MIN.
CONSTRUCTION
ESCUTCHEON METAL SCREWS AT 6" 0.C.
PIPE THRU ROOF
SEE PLUMBING ROOF POP-OFF 1" MIN. CLEARANCE
IF DRAWING IS NOT 30X42 THEN IT IS NOT TO SCALE
CONCRETE YARD BOX PLANS FOR SIZE DRAIN LINE Location
BALL VALVE FOOTING
MIN. 1" AIR BREAK AMERI-VENT THIMBLE
Drawing No.
3/4" PLYWD. LA
6/26/2017 3:30:25 PM

DECKING O/ CLG. JANITOR SINK APPROVED DOUBLE WALL TYPE "B"


Project Manager
JOISTS (WHERE VENT FLUE FROM WATER HEATER.
REQUIRED) REFER TO PLANS FOR SIZE. SJ

P-500
TYPE 'K' COPPER
Project No.
BELOW GROUND
13025
MAKE P.O.C. TO BUILDING SERVICE LINE Date Plotted
APPROX. 5'-0" OUTSIDE OF BUILDING
06/26/2017

COLD WATER MAIN - 01 16 PIPING THRU ROOF 12 WATER HEATER CONNECTION 8 FLUE THRU ROOF 4
14-037
NOTE: SITE PLAN IS FOR REFERENCE ONLY. GENERAL NOTES:

DESIGN OF FIRE WATER SUPPLY SYSTEM SHOWN ON CIVIL SHEET C-301. 1. SCOPE OF WORK: DESIGN AND INSTALLATION OF AN AUTOMATIC FIRE SPRINKLER SYSTEM THROUGHOUT THE
EAST AND WEST BUILDINGS AND A CLEAN AGENT FIRE SUPPRESSION SYSTEM IN THE DATA CENTER ROOM ON
LEVEL 1 OF THE EAST BUILDING FOR THE TORRANCE TRANSIT TERMINAL IN TORRANCE, CA.
1.1. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 13, 2010 EDITION

8" PVC WATER


1.2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 24, 2010 EDITION
1.3. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 2001, 2008 EDITION
1.4. CITY OF TORRANCE REQUIREMENTS.

2. PROVIDE A SPRINKLER SYSTEM IN A NONCOMBUSTIBLE BUILDING. THE SPRINKLER SYSTEM DESIGN SHALL
MEET THE FOLLOWING CRITERIA:
2.1. CONFERENCE ROOM, OPERATORS LOUNGE, RESTROOMS, TRAINING ROOM, AND ASSOCIATED SUPPORT
SPACES: WET SYSTEM, WITH K-FACTOR 5.6 QUICK-RESPONSE SPRINKLERS, SPACED TO A MAXIMUM OF 225
SQUARE FEET PER SPRINKLER. THE SYSTEM SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE 0.10 GPM
PER SQUARE FOOT FOR THE MOST REMOTE 1,500 SQUARE FOOT AREA WITH A TOTAL HOSE DEMAND OF 100

8" PV
GPM (LIGHT HAZARD). QUICK RESPONSE SPRINKLER DESIGN AREA REDUCTION WILL BE APPLIED IN
8607 Venice Boulevard Los Angeles, CA 90034
ACCORDANCE WITH NFPA 13 SECTION 11.2.3.2.3. tel: 310. 559. 4717 fax: 310. 559. 9174

C WA
2.2. COMMERCIAL AREAS: TRASH/RECYCLING ROOM, AND STORAGE ROOM: WET SYSTEM WITH K-FACTOR 5.6
THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND
QUICK-RESPONSE SPRINKLERS, SPACED TO A MAXIMUM OF 100 SQUARE FEET PER SPRINKLER. THE ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE
SYSTEM SHALL BE HYDRAULICALLY DESIGNED TO PROVIDE 0.20 GPM PER SQUARE FOOT FOR THE MOST PROPERTY OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED,

T ER
DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR
REMOTE 1,500 SQUARE FOOT AREA WITH A TOTAL HOSE DEMAND OF 250 GPM (ORDINARY HAZARD GROUP PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE
FH II).
BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE
ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS
SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE
25' 2.3. SPRINKLER DEFLECTORS SHALL BE ORIENTED PARALLEL TO THE CEILING AND OR ROOF SLOPE IN RESTRICTIONS.
ACCORDANCE WITH NFPA 13 SECTION 8.6.4.2.1. THE DISTANCE BETWEEN SPRINKLERS SHALL BE MEASURED
PARALLEL TO THE CEILING AND/OR ROOF SLOPE IN ACCORDANCE WITH NFPA 13 SECTION .
2.4. SPRINKLERS SHALL BE LOCATED TO AVOID OBSTRUCTIONS AS REQUIRED BY NFPA 13 SECTIONS 8.6.5 AND
WEST BUILDING FDC 8.10.6. SPRINKLERS SHALL BE PROVIDED BELOW FIXED OBSTRUCTIONS OVER 4 FT. WIDE. No. Distribution/Revision Date
EAST BUILDING FDC 20' 30% Design Review/Cost Estimate 8.15.2013
3. SYSTEM DESIGN AND INSTALLATION SHALL BE PER CBC/CFC CHAPTER 9, AND NFPA 13. MATERIALS TO BE UL 65% Construction Documents 11.15.2013
8" AND FM APPROVED OR LISTED. SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH NFPA 13 City Submittal 12.17.2013
P VC
WA 95% Construction Documents 03.14.2014
T 8" PVC WATER 9. ALL FIRE SPRINKLER SYSTEM DEVICES AND EQUIPMENT SHALL BE THE LATEST AVAILABLE FROM THE 100% Cost Estimate 04.18.2014
ER
MANUFACTURER, SOLID IN CONSTRUCTION, AND CHOSEN TO MATCH THE AESTHETICS OF THE BUILDING. City Submittal - Backcheck #1 09.01.2015
City Submittal 03.01.2017
10. INSTALL AMES IN-BUILDING RISER. CONNECT TO UNDERGROUND APPROX. 5 FEET. UNDERGROUND MAINS AND
SPRINKLER RISER LEAD-IN CONNECTIONS SHALL BE FLUSHED BEFORE CONNECTION IS MADE TO SPRINKLER PIPING. Permit Amendment 04.10.2017

7. PROVIDE 1-INCH OUTLET IN SHELL CONDITIONS FOR FUTURE TENANT IMPROVEMENT.

DA
DC
W
10. WATER METER SHALL BE INSTALLED PRIOR TO FINAL.

FW
WEST
BUILDING
11. ALL SPRINKLERS PIPING SHALL REMAIN UNCOVERED UNTIL INSPECTED.

8" 12. THE SPRINKLER SYSTEM WILL BE MONITORED BY A CENTRAL STATION SIGNALING SYSTEM FURNISHED AND
PV INSTALLED BY THE ALARM CONTRACTOR. ALL TAMPER SWITCHES AND WATER FLOW INDICATORS SHALL BE
C INSTALLED BY THE SPRINKLER CONTRACTOR AND WIRED TO THE CENTRAL STATION SIGNALING SYSTEM BY
W
AT THE ALARM CONTRACTOR.
ER
13. CONNECTIONS TO PROTECTED PREMISES AND SUPERVISING STATION FIRE ALARM SYSTEMS SHALL BE TESTED
TO VERIFY PROPER IDENTIFICATION AND TRANSMISSION OF ALARMS FROM AUTOMATIC FIRE EXTINGUISHING

W
SYSTEMS.

14. ALL VALVES CONTROLLING THE WATER SUPPLY FOR AUTOMATIC SPRINKLER SYSTEMS AND WATER FLOW
SWITCHES ON ALL SPRINKLER SYSTEMS SHALL BE SUPERVISED. Fire Protection Engineering
Aon Fire Protection Engineering Corporation
15. THE SPRINKLER FLOW SWITCH SHALL BE TESTED TO CONFIRM THAT WHEN THE INSPECTOR'S TEST VALVE IS 707 Wilshire Boulevard | Suite 2600
ACTIVATED AN ALARM WILL SOUND NO MORE THAN 90 SECONDS AFTER INITIAL FLOW. Los Angeles, CA 90017
t +1.213.630.2020 | f + 1.213.630.2098
Fire Protection | Code | Risk
16. FLOW SWITCH SHALL BE CONNECTED TO A 10-INCH OUTSIDE ALARM BELL OR OTHER AUDIBLE ALARM DEVICE Life Safety | Security
AT EACH RISER. APPROVED IDENTIFICATION SIGNS SHALL BE PROVIDED ON THE OUTSIDE ALARM BELL www.aonfpe.com
"SPRINKLER FIRE ALARM - WHEN ALARM SOUNDS CALL 911 / FIRE DEPARTMENT". Project #: 1913055-000

17. ALL INSPECTOR'S TEST CONNECTIONS AND LOW POINT DRAINS SHALL BE PER NFPA 13 (UNLESS NOTED
OTHERWISE) AND SHALL BE DISPLAYED ON SHOP DRAWINGS. MOUNTING HEIGHTS OF CONTROL VALVES SHALL ES
PROF S I ONA
BE 5'-0" A.F.F. MOUNT CONTROL VALVES FOR INSPECTOR'S TEST CONNECTION AND LOW POINT DRAINS INSIDE D L
RE

E
BUILDING. PIPE DRAIN LINES TO THE SANITARY DRAIN OR OTHER APPROVED LOCATION. PROVIDE FREEZE

EN
ST

GI
PROTECTION FOR ALL DRY PIPE AUXILIARY DRAINS.

I
REG

NEER
8"
PV 18. SIGNAGE SHALL BE PROVIDED AS REQUIRED, INCLUDING "RISER ROOM IDENTIFICATION". FP 1 5 73
C
W EXP. 6-30-17
AT 19. A LABEL OF THE SELF-ADHESIVE TYPE SHALL BE PLACED ON THE FIRE DEPARTMENT CONNECTION OR ON THE
ER
RISER FOR FIRE SPRINKLER SYSTEM AND SHALL INCLUDE THE DATE OF INSTALLATION AND/OR DATE SERVICE
WAS PERFORMED AND LICENSED NUMBER OF PERSON PERFORMING SERVICE WORK.
EAST

W
BUILDING
20. REFER TO THE ARCHITECTURAL DRAWINGS FOR ACTUAL BUILDING DIMENSIONS AND DETAILS. DO NOT SCALE
"FP" DRAWINGS FOR CONSTRUCTION PURPOSES.

21. REFER TO THE FIRE PROTECTION SPECIFICATIONS FOR ADDITIONAL INFORMATION REGARDING THE FIRE
PROTECTION SYSTEM.

22. SPRINKLER SYSTEM DEFERRED DESIGN/SHOP DRAWINGS SHALL BE SIMULTANEOUSLY SUBMITTED TO THE
BUILDING/FIRE DEPARTMENT AND THE OWNER FOR REVIEW AND APPROVAL.

23. ROOF DRAIN AND OVERFLOW PIPING WITHIN THE BUILDING SHALL UTILIZE APPROVED DRAINAGE FITTINGS.

DA
DC
FW
SPRINKLER RISER FH
SYSTEM 1
SPRINKLER RISER
SYSTEM 2

8"
PV
C
W
AT
ER

City of Torrance
Torrance Transit Park and Ride
FH Regional Terminal
465 Crenshaw Blvd.
NORTH
Torrance, CA 90503

Torrance Transit
SITE PLAN
1 SCALE: 1" = 20'-0" ELBOW Park and Ride
24" MAX
FLEXIBLE COUPLING (FC)
(TYPICAL FOR EACH RISER) TO SYSTEM 2 Regional Terminal
CONTRACTOR NOTES: ABOVE GROUND PIPING NOTES: ELBOW SYMBOL LEGEND
1. THE SPRINKLER CONTRACTOR SHALL BE C-16 LICENSED BY THE STATE OF CALIFORNIA FOR 1. ALL PIPING SHALL BE LISTED IN ACCORDANCE WITH NFPA 13 SECTION 6.3.1.1. FLEXIBLE COUPLING (FC)
24" MAX
TO SYSTEM
4-WAY BRACE
(TYPICAL FOR EACH RISER)
24" MAX
TO SYSTEM 1 X" DIAMETER OF PIPE
PHASE II
DESIGN AND INSTALLATION OF AUTOMATIC FIRE SPRINKLER SYSTEMS. PIPE
2. ALL FIRE SYSTEM PIPING SHALL BE PROVIDED AS FOLLOWS: X-X CLIENT PROJECT #: B2013-15
4-WAY BRACE ALARM BELL FC ALARM BELL LENGTH OF PIPE
2. THE SPRINKLER CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND COORDINATE WITH 2.1. PIPE SHALL BE BLACK STEEL COMPLIANT WITH ASTM A 53. (SEE PLANS FOR LOCATION) (SEE PLANS FOR LOCATION) Drawing Title
OTHER TRADES PRIOR TO INSTALLATION. 2.2. SCHEDULE 40 PIPE IS REQUIRED FOR PIPE DIAMETER OF 2 INCHES OR LESS. 300 LB. PRESSURE 300 LB. PRESSURE GAUGE SPRINKLER RISER
2.3. SCHEDULE 10 PIPE IS PERMITTED FOR PIPE DIAMETERS OF 212 INCHES OR GREATER. (TYPICAL FOR EACH RISER)
3. SPRINKLER CONTRACTOR TO COORDINATE AND ADJUST SPRINKLERS TO ELECTRICAL,
MECHANICAL, STRUCTURE AND ALL OTHER TRADES AT NO ADDITIONAL COST TO THE OWNER.
2.4. PIPING FOR EXTERIOR INSTALLATION AND DRAIN PIPING SHALL BE SCHEDULE 40 HOT DIPPED
GALVANIZED, UNLESS OTHERWISE NOTED.
GAUGE

POTTER FLOW SWITCH 2" TEST AND DRAIN VALVE WITH POTTER FLOW SWITCH
2" TEST AND DRAIN VALVE WITH
MINIMUM 12-INCH RELIEF VALVE
RISER NIPPLE SITE PLAN AND
INSTALL OFFSETS AS REQUIRED TO AVOID CLASHES.
4. JOINING OF PIPE AND FITTINGS TO BE DONE WITH GROOVED COUPLINGS WHEN LIGHTWALL PIPE IS USED
WIRING BY OTHERS MINIMUM 12-INCH RELIEF VALVE WIRING BY OTHERS
(TYPICAL FOR EACH RISER)
(TYPICAL FOR EACH RISER)
SPARE SPRINKLER CABINET
RISER ELBOW
GENERAL NOTES
4" BUTTERFLY SPARE SPRINKLER CABINET END CAP
4. THE SPRINKLER CONTRACTOR IS RESPONSIBLE FOR ALL CUTTING, SEALING, PATCHING, AND OR THREADED CAST IRON OR DUCTILE IRON FITTINGS WITH THREADABLE PIPE.
PAINTING REQUIRED FOR INSTALLATION OF THE SPRINKLER SYSTEM. ALL PENETRATIONS OF VALVE WITH TAMPER
2" DRAIN, DISCHARGE TO APPROVED 4" BUTTERFLY VALVE 2" DRAIN, DISCHARGE TO APPROVED
RATED ASSEMBLIES SHALL BE FIRE STOPPED WITH AN APPROVED MATERIAL AS PRESCRIBED 5. ALL WELDING TO BE DONE BY CERTIFIED WELDERS. PROVIDE WELDING PROCEDURE AND QUALIFICATIONS SWITCH STRUCTURAL HANGER
LOCATION. COORDINATE WITH WITH TAMPER SWITCH LOCATION. COORDINATE WITH
IN THE CBC. IN ACCORDANCE WITH NFPA 13 SECTION 6.5.2. PLUMBING CONTRACTOR PLUMBING CONTRACTOR
(TYPICAL FOR EACH RISER) SPLAY HANGER
(TYPICAL FOR EACH RISER)
FLEXIBLE COUPLING (FC) FLEXIBLE COUPLING (FC) FC
5. DELIVERY OF ALL MATERIALS AND EQUIPMENT TO THE JOB SITE SHALL BE SCHEDULED TO 6. ALL PIPING AND ATTACHED APPURTENANCES SUBJECTED TO SYSTEM WORKING PRESSURE SHALL BE
ASSURE COMPLIANCE WITH THE PREDETERMINED CONSTRUCTION SCHEDULE. THE HYDROSTATICALLY TESTED AT 200 PSI, OR 50 PSI IN EXCESS OF THE SYSTEM WORKING PRESSURE, FLANGE FLANGE LATERAL OR LONGITUDINAL EARTHQUAKE BRACE
24" MAX 24" MAX
Scale: 1/8" = 1'-0"
CONTRACTOR SHALL BE RESPONSIBLE FOR STORAGE AND HANDLING ALL MATERIALS AND WHICHEVER IS GREATER, AND SHALL MAINTAIN THAT PRESSURE WITHOUT LOSS FOR 2 HOURS. (PROJECT 6" ABOVE FINISH GRADE 6" ABOVE FINISH GRADE
IF DRAWING IS NOT 30"x42" THEN IT IS NOT TO SCALE
EQUIPMENT ON THE JOB SITE, INCLUDING FURNISHING OF ANY STORAGE FACILITIES OR INSPECTOR SHALL WITNESS AND CONFIRM COMPLIANCE). 4 WAY EARTHQUAKE BRACE Location
STRUCTURE REQUIRED. Drawing No.
7. SYSTEM RISERS SHALL NOT BE CONNECTED TO UNDERGROUND MAINS AND LEAD IN CONNECTIONS UNTIL LA
6. SPRINKLER CONTRACTOR SHALL COMPLETE AND SIGN CONTRACTOR'S MATERIAL AND TEST UNDERGROUND PIPING HAS BEEN HYDROSTATICALLY TESTED AND FLUSHED. WHERE UNDERGROUND MINIMUM 2" CLEARANCE MINIMUM 2" CLEARANCE FIRE RATED WALL PENETRATION Project Manager

CERTIFICATE FOR THE ABOVEGROUND PIPING. THIS FORM SHALL BE GIVEN TO THE PROJECT PIPING IS FLUSHED AND NOT IMMEDIATELY CONNECTED TO THE OVERHEAD PIPING, THE RISER SHALL BE
KF
INSPECTOR WHO WILL FORWARD TO DSA FOR FILLING IN PROJECT RECORDS. CAPPED OR OTHERWISE PROTECTED TO PREVENT DEBRIS, DIRT, OR ANIMALS FROM ENTERING INTO THE
AMES IN-BUILDING RISER AMES IN-BUILDING RISER SEISMIC SEPARATION ASSEMBLY Project No.

7. OWNER IS TO BE PROVIDED WITH TEST CERTIFICATES, CARE & MAINTENANCE BOOK (NFPA 25
- CALIFORNIA AMENDED), AND A SPARE HEAD CABINET WITH SPRINKLERS AND A WRENCH PER
UNDERGROUND PIPING (WITNESSED BY THE PROJECT INSPECTOR).

# #
#
HYDRAULIC REFERENCE NODES Date Plotted
13025 FP-101
NFPA 13.
WEST BUILDING RISER DETAIL EAST BUILDING RISER DETAIL 04/10/2017
2 NTS
3 NTS
WATER FLOW BELL
8607 Venice Boulevard Los Angeles, CA 90034
tel: 310. 559. 4717 fax: 310. 559. 9174

THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND


ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED,
DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR
PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE
BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE
ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS
6 SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE
1 2 3 4 4.2 5 6 RESTRICTIONS.

No. Distribution/Revision Date


30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
95% Construction Documents 03.14.2014
100% Cost Estimate 04.18.2014
City Submittal - Backcheck #1 09.01.2015
H City Submittal 03.01.2017
Permit Amendment 04.10.2017
3
Transit Store
101 KEYNOTES
Main Electrical
3
Room
1 OPEN TO SKY
107
2 NON-COMBUSTIBLE EXTERIOR
SYMBOL LEGEND
Electrical Yard ROOF OR CANOPY
1
(NFPA 13, 8.15.7.2) SPRINKLER RISER
110 Commercial 3 SPACE SPRINKLERS TO AVOID
3Space STRUCTURAL OBSTRUCTION WATER FLOW BELL
3 102 (NFPA 13 SECTION 8.6.5).
Storage
106
I
Trash /
1
Recycling
Room 10'-0 5/16"
SPRINKLER SCHEDULE & LEGEND
108 SYMBOL SPRINKLER DESCRIPTION K-FACTOR TEMP. FINISH SIN QUANTITY
Office
3 Unisex Toilet
104
105 UPRIGHT SPRINKLER - QUICK RESPONSE 5.6 155 F BRASS TY3131 24
Fire Protection Engineering
PENDENT SPRINKLER CONCEALED - QUICK RESPONSE 5.6 155 F WHITE TY3531 9 Aon Fire Protection Engineering Corporation
J 707 Wilshire Boulevard | Suite 2600
SIDEWALL SPRINKLER - QUICK RESPONSE 5.6 155 F WHITE TY3331 0 Los Angeles, CA 90017
t +1.213.630.2020 | f + 1.213.630.2098
Janitor's Closet Fire Protection | Code | Risk
3 Security
109 Life Safety | Security
103 HEAD CAB'T & WRENCH(ES) PROVIDED TOTAL COUNT THIS FLOOR = 33 www.aonfpe.com
Project #: 1913055-000
2 NOTE: WHERE SPRINKLERS ARE EXPOSED TO CORROSIVE CONDITIONS PROVIDE CORROSION PROTECTION
FP-101

K
ES
SPRINKLER SYSTEM RISER PROF S I ONA
D
PROVIDE MAXIMUM 2-INCH NOTE: ALL FIRE SPRINKLER SYSTEM DEVICES AND EQUIPMENT SHALL BE THE LATEST AVAILABLE FROM THE RE
L

EN
ST
CLEARANCE BETWEEN RISER MANUFACTURER, SOLID IN CONSTRUCTION, AND CHOSEN TO MATCH THE AESTHETICS OF THE BUILDING.

GI
I
REG

NEER
FLANGE AND WALL
5.1 FP 1 5 73
EXP. 6-30-17

NORTH

0 4' 8' 16'

LEVEL 1 - WEST BUILDING


1 1/8" = 1'-0"

SCH. 40 PIPE AS REQUIRED

1 FLEXHEAD SPRINKLER DROP STEEL I-BEAM


2"x 521 HILTI KWIK BOLT TZ
(ESR 1917)

CORRUGATED STAINLESS STEEL HOSE


WITH STAINLESS STEEL BRAID AVAILABLE
IN 2', 3', 4', 5' & 6' LENGTHS BEAM CLAMP
TOLCO FIG. 65
WRAP AROUND BEAM
ADJUSTABLE HUB FLANGE NOT LESS
NO-THREAD SWIVEL SWAY THAN 1 IN.
BRACE FITTING
MULTI-PORT BRACKET
TOLCO FIG. 909 (2)
ALL THREAD ROD
TOLCO FIG. 100
TOLCO FIG. 1000 ``FAST RETAINER STRAP SHALL BE NOT LESS
CLAMP'' SWAY BRACE THAN 16 GAUGE THICKNESS AND NOT LESS
ATTACHMENT THAN 1 IN. WIDE FOR PIPE 8 IN. OR LESS
OPA-0672-07 T-BAR CLNG TOLCO FIG. 69
SURGE RESTRAINER
TOLCO FIG. 25

TOLCO
ADJUSTABLE RING HANGER
TOLCO FIG. 200
Model #2024,2036,2048,2060,2072
SPRINKLER PIPE

4 WAY EARTHQUAKE BRACE AT CONCRETE SYMBOL =


FLEXIBLE ARMOVER INSTALLATION
NTS
HANG TO TOP OR BOTTOM FLANGE OF I-BEAM

City of Torrance
HANGER AT STEEL BEAM SYMBOL = Torrance Transit Park and Ride
STEEL BEAM STEEL BEAM
Regional Terminal
NTS 465 Crenshaw Blvd.
Torrance, CA 90503

I-BEAM
TOLCO TOLCO
Torrance Transit
SWAY BRACE SWAY BRACE
ATTACHMENT
TOLCO FIG. 909
ATTACHMENT
TOLCO FIG. 909
Park and Ride
SWAY BRACE ATTACHMENT TO STEEL
I-BEAM TOLCO FIG. 800
SWAY BRACE ATTACHMENT TO STEEL
I-BEAM TOLCO FIG. 800
Regional Terminal
45 -59 45 -59 SWIVEL SWAY BRACE
ATTACHMENT PHASE II
TOLCO FIG. 909
SWAY BRACE CLAMP OR SWAY BRACE ATTACHMENT TO STEEL CLIENT PROJECT #: B2013-15
SWAY BRACE ATTACHMENT OR
TOLCO FIG. 1000 I-BEAM TOLCO FIG. 800 HANGER AND SEISMIC RESTRAINT NOTES:
Drawing Title
TOLCO FIG. 909
1. PROVIDE SEISMIC BRACING IN CONFORMANCE WITH NFPA 13 REQUIREMENTS.

1" SCH 40 PIPE 1" SCH 40 PIPE BRACE PIPE 1" SCH. 40
2. HANGER LOCATIONS FOR ALL PIPING SHALL BE IN COMPLIANCE WITH NFPA 13 SECTIONS 9.1 THROUGH 9.2.5.4. WEST BUILDING
R
``FAST CLAMP'' SWAY BRACE ATTACHMENT
3. WHENEVER POSSIBLE, LIMIT BRANCH LINE PIPING HANGERS TO MAXIMUM 6 INCHES IN LENGTH BETWEEN THE POINT OF SPRINKLER PIPING
ATTACHMENT TO STRUCTURAL MEMBERS AND THE TOP OF PIPING TO MEET THE REQUIREMENTS OF NFPA 13 SECTIONS
PIPE TO BE BRACED
TOLCO FIG. 1000
9.3.6.1 THROUGH 9.3.6.4. PLAN
4. WHERE SPRINKLERS PENETRATE SUSPENDED CEILINGS, PROVIDE FLEXIBLE SPRINKLER DROPS TO MEET THE
PIPE TO BE BRACED
REQUIREMENTS OF ASCE 7-05 SECTION 13.5.6.1(E).
PIPE CLAMP
TOLCO FIG. 4A 5. FLEXIBLE COUPLINGS SHALL BE INSTALLED AS FOLLOWS:
Scale: 1/8" = 1'-0"
IF DRAWING IS NOT 30"x42" THEN IT IS NOT TO SCALE
Location
a. WITHIN 24 IN. OF THE TOP AND BOTTOM OF ALL RISERS; Drawing No.
b. ABOVE AND BELOW ANY INTERMEDIATE POINTS OF SUPPORT FOR A RISER OR OTHER VERTICAL PIPE. LA
BL BL
BRANCH LINE RESTRAINT USING c. WITHIN 12 IN. ABOVE AND WITHIN 24 IN. BELOW THE FLOOR IN MULTISTORY BUILDINGS. WHEN THE FLEXIBLE Project Manager

LONGITUDINAL BRACE SYMBOL = LATERAL BRACE SYMBOL = LATERAL BRACE SYMBOL =


BLX
COUPLING BELOW THE FLOOR IS ABOVE THE TIE-IN MAIN TO THE MAIN SUPPLYING THAT FLOOR, A FLEXIBLE KF
COUPLING SHALL BE PROVIDED ON THE VERTICAL PORTION OF THE TIE-IN PIPING. Project No.
NTS NTS
NTS
Date Plotted
13025 FP-110
04/10/2017
6.9 7 8 9 10 11 12 13

2 8607 Venice Boulevard Los Angeles, CA 90034


tel: 310. 559. 4717 fax: 310. 559. 9174

THESE DRAWINGS AND SPECIFICATIONS AND IDEAS, DESIGNS AND


ARRANGEMENTS REPRESENTED THEREBY ARE AND SHALL REMAIN THE
PROPERTY OF THE ARCHITECT: NO PART THEREOF SHALL BE COPIED,
DISCLOSED TO OTHERS, OR USED IN CONNECTION WITH ANY WORK OR
PROJECT OTHER THAN THE SPECIFIED PROJECT FOR WHICH THEY HAVE
BEEN PREPARED AND DEVELOPED WITHOUT THE WRITTEN CONSENT OF THE
Commercial ARCHITECT. VISUAL CONTACT WITH THESE DRAWINGS OR SPECIFICATIONS
SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE
Space RESTRICTIONS.

109

No. Distribution/Revision Date


30% Design Review/Cost Estimate 8.15.2013
65% Construction Documents 11.15.2013
City Submittal 12.17.2013
95% Construction Documents 03.14.2014
AREA 1

2
100% Cost Estimate 04.18.2014
City Submittal - Backcheck #1 09.01.2015
C5 City Submittal 03.01.2017
Permit Amendment 04.10.2017
B
AREA 2

INSTALL SPRINKLERS UNDER STAIR Elevator Machine


3 Room
LANDING. PIPING SERVING STAIR
SPRINKLERS SHALL BE CORED THROUGH OPEN TO CEILING ABOVE
112
THE WALL ALONG COLUMN GRID LINE B. 2
PIPING SHALL BE CONCEALED IN SOFFIT 2
FRAMING BELOW THE STAIR.
Lobby 2

10' - 0" 110

C
8' - 0"
Unisex Toilet
Interview Room
2
Women's Public
Restroom 119 Men's Shower Women's Shower
117
9' - 0" 9' - 0"
113 122A 9' - 0"
123A Fire Protection Engineering
Electrical Room Aon Fire Protection Engineering Corporation
9' - 0" 10' - 0" 707 Wilshire Boulevard | Suite 2600
Women's Exercise Room 125 1
Men's Restroom Los Angeles, CA 90017
Restroom
10' - 0" 124 t +1.213.630.2020 | f + 1.213.630.2098
10' - 0" Fire Protection | Code | Risk
Copy Room 122 123
Open Offices Life Safety | Security
www.aonfpe.com
C6 10'120
- 0" 9' - 0"
Visiting Operators 116 9' - 0" 9' - 0" Project #: 1913055-000
D Restroom
2 10' - 0" Vending 9' - 0"
114 ES
9' - 0" 127 INSTALL SIDEWALL SPRINKLERS UNDER EXTERIOR STAIR IN PROF S I ONA
D L
E ACCORDANCE WITH CITY OF TORRANCE REQUIREMENTS. RE

TE

EN
Quiet Room

IS

GI
Pantry PIPING SERVING STAIR SPRINKLERS SHALL BE CORED

REG
Data Center

NEER
Operator's THROUGH THE WALL ALONG COLUMN GRID LINE 13. SEAL ALL
145 10' - 0"
Lounge 144 PENETRATIONS THROUGH EXTERIOR WALL.
130 FP 1 5 73
Vestibule
9' - 0" 128 EXP. 6-30-17
Men's Public 10' - 0" PROVIDE CLEAN AGENT FIRE
Dispatch 128A SUPPRESSION SYSTEM IN
Restroom 10' - 0"
ACCORDANCE WITH NFPA 2001 IN
2 9' - 0" 118 DATA CENTER ROOM IN LIEU OF
115
Janitor Closet SPRINKLER AS PERMITTED BY
3 1
FP-101
TORRANCE FIRE DEPARTMENT
2 131
F

Operator's Patio
SYSTEM 1 PROVIDE MAXIMUM 2-INCH
134 SYSTEM 2 CLEARANCE BETWEEN
RISER FLANGE AND WALL
1 1

AREA 2 AREA 3
C7

LEVEL 1 - EAST BUILDING


1 1/8" = 1'-0" NORTH

0 4' 8' 16'

6.9
7 8 9 10 11 12 13

C5

Storage
3
201B City of Torrance
10' - Torrance Transit Park and Ride
0"
2 Regional Terminal
465 Crenshaw Blvd.
9' - Second Floor 2
0" Lobby Torrance, CA 90503

9' - 10' - 201


0" 0"
C
Torrance Transit
Janitor Closet

208 KEYNOTES
Park and Ride
10' -
0"
Conference
Men's Restroom

204
Women's 1 OPEN TO SKY
SYMBOL LEGEND
Regional Terminal
Restroom 2 NON-COMBUSTIBLE EXTERIOR
10' -
202 Hallway
9' -
0"
201A
9' -
0"
205
9' -
0"
Training /
ROOF OR CANOPY
(NFPA 13, 8.15.7.2) SPRINKLER RISER PHASE II
Multipurpose 3 NON-COMBUSTIBLE ELEVATOR
0" IT Closet HOISTWAY WITH NONCOMBUSTIBLE WATER FLOW BELL CLIENT PROJECT #: B2013-15
C6 Room HYDRAULIC FLUID(NFPA 13, 8.15.5.5)
D
10' -
207
209
Drawing Title
0"

E
EAST BUILDING
Storage SPRINKLER SCHEDULE & LEGEND
206 SYMBOL SPRINKLER DESCRIPTION K-FACTOR TEMP. FINISH SIN QUANTITY
SPRINKLER PIPING
Simulator

203 10' - UPRIGHT SPRINKLER - QUICK RESPONSE 5.6 155 F BRASS TY3131 26 PLAN
0"
PENDENT SPRINKLER CONCEALED - QUICK RESPONSE 5.6 155 F WHITE TY3531 88

SIDEWALL SPRINKLER - QUICK RESPONSE 5.6 155 F WHITE TY3331 3

9' - Scale: 1/8" = 1'-0"


0" HEAD CAB'T & WRENCH(ES) PROVIDED TOTAL COUNT THIS FLOOR = 117 IF DRAWING IS NOT 30"x42" THEN IT IS NOT TO SCALE
F Location
NOTE: WHERE SPRINKLERS ARE EXPOSED TO CORROSIVE CONDITIONS PROVIDE CORROSION PROTECTION Drawing No.
LA
Project Manager

NOTE: ALL FIRE SPRINKLER SYSTEM DEVICES AND EQUIPMENT SHALL BE THE LATEST AVAILABLE FROM THE KF
MANUFACTURER, SOLID IN CONSTRUCTION, AND CHOSEN TO MATCH THE AESTHETICS OF THE BUILDING. Project No.

2
LEVEL 2 - EAST BUILDING
NORTH
Date Plotted
13025 FP-111
1/8" = 1'-0"
0 4' 8' 16' 04/10/2017