You are on page 1of 7

Summary Report

Model File: Swimming Pool, Revision 0


2/1/2022
Structure Data 2/1/2022

1 Structure Data
This chapter provides model geometry information, including items such as story levels, point coordinates, and
element connectivity.

1.1 Story Data

Table 1.1 - Story Definitions


Height Master Splice
Tower Name Similar To Color
m Story Story
T1 Story2 1.8 No None No Green
T1 Story1 2.2 No None No Cyan

Page 2 of 7
Loads 2/1/2022

2 Loads
This chapter provides loading information as applied to the model.

2.1 Load Patterns


Table 2.1 - Load Pattern Definitions
Self
Is Auto
Name Type Weight
Load
Multiplier
~LLRF Yes Other 0
Dead No Dead 1
Live No Live 0
SOIL No Live 0
WATER No Live 0

2.2 Functions

2.2.1 Response Spectrum Functions

Table 2.2 - Functions - Response Spectrum - User Defined


Period Damping
Name Value
sec Ratio
UnifRS 0 1 0.05
UnifRS 1 1

2.3 Load Cases

Table 2.3 - Load Case Definitions - Summary


Name Type
Dead Linear Static
Live Linear Static
Modal -
Modal
Eigen
SOIL Linear Static
WATER Linear Static

TABLE: Load
Combination
Definitions
Load
Name Type Is Auto Name SF

Linear
SDL Add No Dead 1
SDL Live 1
Linear
SDLS Add No Dead 1
SDLS Live 1
SDLS SOIL 1
Linear
SDLW Add No Dead 1
SDLW Live 1
SDLW WATER 1
Page 3 of 7
Loads 2/1/2022

Linear
SDLWS Add No Dead 1
SDLWS Live 1
SDLWS WATER 1
SDLWS SOIL 1
Linear
UDL Add No Dead 1.2
UDL Live 1.6
Linear
UDLS Add No Dead 1.2
UDLS Live 1.6
UDLS SOIL 1.6
Linear
UDLW Add No Dead 1.2
UDLW Live 1.6
UDLW WATER 1.6
Linear
UDLWS Add No Dead 1.2
UDLWS Live 1.6
UDLWS WATER 1.6
UDLWS SOIL 1.6

Page 4 of 7
Loads 2/1/2022

Page 5 of 7
Loads 2/1/2022

Design walls against shear force:


340
ϕ = 0.75 ∗ 0.17 ∗ √35 ∗ 1000 ∗ = 256.46
1000
= 79.5

ϕ = 256.46 > = 79.5 So 400 mm wall thickness is adequate.