PLASTIC SLEEVE STEEL BAR Ø16mm@25cm(STAGGERED) PLASTIC SLEEVE STEEL BAR Ø20mm@25cm(STAGGERED)

Ø20mm Ø25mm
75 3 75 75 3 75
WATER STOP WALL REINFORCEMENT WATER STOP WALL REINFORCEMENT
EXPANSION JOINT DETAIL (BOUNDARY WALL) for Wall 1,2&3 m EXPANSION JOINT DETAIL (BOUNDARY WALL) for Wall 4,5&6 m
Scale 1:20 Scale 1:20
PLASTIC SLEEVE STEEL BAR Ø20mm PLASTIC SLEEVE STEEL BAR Ø20mm
Ø20mm Ø25mm
75 3 75 75 3 75
TYPICAL DETAIL FOR MULTI SPAN BEAM REINFORCEMENT
ELEVATION IN EXPANSION JOINT (BOUNDARY WALL) ELEVATION IN EXPANSION JOINT (BOUNDARY WALL)
NOTE: Scale 1:20 Scale 1:20
ALL RETAINING WALLS SHOULD BE SEPARATED
BY EXPANSION JOINT (3cm) FOR MAXIMUM DISTANCE 15m
FIRST POUR CONSTRUCTION JOINT WALL REINFORCEMENT
CONSTRUCTION JOINT
WATER STOPP MAX SPACING 15m IN WINTER
SLAB REINFORCEMENT MAX SPACING 10m IN SUMMER
(IF REQUIRED)
G2-CONCRETE WALL CONSTRUCTION JOINT DETAIL
G1-STRUCTURAL SLAB CONSTRUCTION JOINT DETAIL
DOWELS TO MATCH
10x30mm DEEP FORMED FLEXIBLE JOINT SEALANT CONSTRUCTION JOINT VERTICAL REINFORCEMENT
SURFACE GROOVE UNLESS OTHERWISE NOTED
TOP OF FOOTING
BEND AS REQUIRED
Y16@200x750
30mm SIZE TRIANGULAR SHAPE INDUCED CRACK
WOOD CRACK INDUCER
CONCRETE BLINDING
G3-SLAB ON GRADE CONTRACTION JOINT DETAIL
G4-TYPICAL CONSTRUCTION JOINT BETWEEN WALL & FOUNDATION
JOINTS DETAILS
J3-TYPICAL SECTION THROUGH 150mm RAMP ON GRADE F-JOINTS DETAILS
Y10@150(T)
Reinforcement In Y Dir. TWO BITUMEN
1Y10 (ES)
Y10@200(ES)
Reinforcement In X Dir. COATS
Y10@150(T)
Y10@150(T)
TOP REINFORCEMENT
TOP REINFORCEMENT FLOOR SLAB
REINFORCED CONCRETE SLAB
BOTTOM REINFORCEMENT BOTTOM REINFORCEMENT
PLAIN CONCRETE
POLYTHENE SHEET (250 Microns)
As Plan As Plan As Plan
J4-TYPICAL SECTION THROUGH STAIR ON GRADE
10 X 10
BASE COURSE
STIFFENER COLUMN ANCHORED
SELECTED COMPACTED FILL 98%
IN FLOOR SLABS
MODIFIED PROCTOR TEST
STIFFENER BEAM
FOR REINFORCEMENT FOR REINFORCEMENT A A
REFER TO DETAILS REFER TO DETAILS
CHANGE IN SLAB
ELEVATION
1 2Y16
2Y16 1 1
CONCRETE BLINDING 1
FLOOR SLAB
CONCRETE BLINDING
J5-DETAIL OF SLAB ON GRADE AT FREE EDGE J6-DETAIL OF SLAB ON GRADE AT CHANGE IN ELEVATION PLAN PLAN
4Y12(V) 2Y12(T)
BLOCK WALL TOP REINFORCEMENT R8@200(S) R8@200(S)
BOTTOM REINFORCEMENT 2Y12(B)
SLAB ON 3Y20(T) TOP REINFORCEMENT
GRADE Y10@200
BOTTOM REINFORCEMENT
C1-STIFFENER COLUMN TYPICAL DETAIL C2-STIFFENER BEAM TYPICAL DETAIL
Reinforcement In Y Direction
3Y20(B)
SECTION A-A SECTION A-A
C-TYPICAL DETAILS OF STIFFENER BEAMS AND STIFFERNER COLUMNS IN INTERNAL BLOCK WALLS
J7-TYPICAL DETAIL OF GROUND SLAB
THICKENING BELOW BLOCK WALLS
Typical Single Foot
J-DETAILS OF SLAB ON GRADE K-TYPICAL FLAT SLAB REINFORCEMENT DETAIL L-TYPICAL RAFT REINFORCEMENT DETAIL