You are on page 1of 1

Document Reference LEEA-030.

1a2

ODEKOLE INTERNATIONAL SERVICES LIMITED


REPORT OF THOROUGH EXAMINATION
This report complies with the requirements of the Lifting Operations and Lifting Equipment Regulations 1998

Date of Thorough Examination: 25-05-2022 Date of Report: 25-05-2022 Report number: ODK/T&G/0522/RP/8921
Name and Address of employer for whom the thorough Address of premises at which the examination was made:
examination was made: THOMPSON AND GRACE OPERATIONAL BASE
INVESTMENT LIMITED STANDARD: BS 5974
Description and identification of the equipment:
Safe Working Load(s): Previous Proof Date of last
UNIT ID NUMBER: TGIL/RGP/001 Load Applied: thorough
RIGGING PLATFORM LENGTH = 9.00M examination:
STEEL FABRICATED RIGGING WIDTH = 6.10M 2 TONNES 3 TONNES
PLATFORM WITH 13 STANCHIONS HEIGHT = 6.53M 31/05/2021
25 RIGGING / LIFTING POINTS
TEST: VISUAL TEST DONE ON POINT LB1 – LB25 (25 POINTS) ON THE RIGGING PLATFORM
SCOPE

RESULT: SUCCESFUL…NO CRACKS OR PERMANENT DEFORMATION ON THE PLATFORM

Was the examination carried out?


Is this the first examination after installation YES NO X Within an interval of 6 months? YES X NO
or assembly at a new site or location? Within an interval of 12 months? YES NO
In accordance with an examination
If the answer to the above question is YES YES NO YES X NO
scheme?
has the equipment been installed correctly? After the occurrence of exceptional
YES NO
circumstances?
Identification of any part found to have a defect which is or could become a danger to persons and a description of the defect:
(If none state NONE): NONE
Is the above an existing or imminent danger to persons *Note-This is a reportable defect YES NO X
Is the above a defect which is not yet but could become a danger to persons:
YES by:
(If YES state the date by when)
Particulars of any repair, renewal or alteration required to remedy the defect identified above:
Particulars of any tests carried out as part of the examination: (If none state NONE)

IS THIS EQUIPMENT SAFE TO OPERATE? YES X NO


Name & Qualifications of person Name of person authenticating this DUE DATE:24-11-2022
making this report: report:

MICHAEL AGADA
LEEA I, II, & III
Signature:
Name and address of employer of persons making and authenticating this report:
ODEKOLE INTERNATIONAL SERVICES LIMITED
7 Sweez Close Orazi Port Harcourt

Version 1 January 2015 Document Originator K Crilly