You are on page 1of 11

LABORATORY 7

Cylinder Sequencing-Oscillating Cylinder

Name: ____________________ Date Submitted:_________________


Course & Section: ____________ Score:________________________

Components Used

 Double Acting Cylinder


 3/2 roller lever valve
 3/2 push button valve
 5/2 pilot operated direction control valve
 Air supply unit

Procedures
Step 1: Open the pneumatic developer.

Step 2: Click the “+” sign, then fill up the examples needed to perform the
operations.

Step 3: Choose all the materials needed. Click the “tools” in the upper left corner of
the screen, and then click the “clock” sign to portray the given instructions.
Step 4: Select the materials that corresponds to your laboratory, then drag them to
your window.

Step 5: Configure the 5/2 way DVC valve, double click and select“piloted” both
sides, then ON the “spring return”.

To set up the two 3/2 way DVC, double click and select “button” on the right side,
and ON the “spring return” on both sides.

Then, followed by the last one 3/2 way DVC, which is on the left side, double click
and select “roller” on the the left side and ON the “spring return”.
Step 6: Exhaust points, connect all the terminals, be sure it is connected and
configured. For the remaining terminals, double click and select “Exhaust not
Channeled” to configure the exhaust points.

Step 7: Flow simulation to simulate the process. Press the play button to operate the
simulation. It shows the Double Acting Cylinder push and pull. Lastly, save your
work.
LABORATORY 6
Pneumatic Circuit for Embossing Application
Name: ____________________ Date Submitted:_________________
Course & Section: ____________ Score:________________________

Components Used

 Double Acting Cylinder


 3/2 roller lever valve
 3/2 push button valve
 5/2 pilot operated direction control valve
 Air supply unit
 Regulator

Procedures
Step 1: Open the pneumatic developer.

Step 2: Click the “+” sign, then fill up the examples needed to perform the
operations.

Step 3: Choose all the materials needed. Click the “tools” in the upper left corner of
the screen, and then click the “clock” sign to portray the given instructions.
Step 4: Select the materials that corresponds to your laboratory, then drag them to
your window.

Step 5: Configure the 5/2 way DVC valve, double click and select“piloted” both
sides, then ON the “spring return”.

To set up the right area of the 3/2 way DVC, double click and select “button” on the
right side, and ON the “spring return” on the left side.

Then, followed by the left area of the 3/2 way DVC, double click and select “roller”
on the the right side and ON the “spring return” on the both side.
Lastly, for the remaining 3/2 way DVC, double click and select “button” on the right
side, and “button with
lock” on the left side, then ON
the “spring return” both
sides.

Step 6: Exhaust points, connect all the terminals, be sure it is connected and
configured. For the remaining terminals, double click and select “Exhaust not
Channeled” to configure the exhaust points.

Step 7: Flow simulation to simulate the process. Press the play button to operate the
simulation. It shows the Double Acting Cylinder push and pull. Lastly, save your
work.
LABORATORY 5
Pneumatic Circuit for Shuttle Valve Operation
Name: ____________________ Date Submitted:_________________
Course & Section: ____________ Score:________________________

Components Used

 Double Acting Cylinder


 3/2 roller lever valve
 3/2 push button valve
 3/2 pedal with lock
 5/2 pilot operated direction control valve
 Air supply unit
 Shuttle valve

Procedures
Step 1: Open the pneumatic developer.

Step 2: Click the “+” sign, then fill up the examples needed to perform the
operations.

Step 3: Choose all the materials needed. Click the “tools” in the upper left corner of
the screen, and then click the “clock” sign to portray the given instructions.
Step 4: Select the materials that corresponds to your laboratory, then drag them to
your window.

Step 5: Configure the 5/2 way DVC valve, double click and select“piloted” both
sides, then ON the “spring return”.

To set up the right area of the 3/2 way DVC, double click and select “button” on the
right side, and ON the “spring return” on the left side.

Then, followed by the left area of the 3/2 way DVC, double click and select “roller”
on the the right side and ON the “spring return” on the both side.
Next, set up the center 3/2 way DVC, double click and select “pedal with lock” on the
right side, and ON the “spring return” on the left side.

Lastly, for the remaining 3/2 way DVC, double click and select “button” on the right
side, and “button with lock” on the left side, then ON the “spring return” both sides.

Step 6: Exhaust points, connect all the terminals, be sure it is connected and
configured. For the remaining terminals, double click and select “Exhaust not
Channeled” to configure the exhaust points.
Step 7: Flow
simulation
to simulate
the process.
Press the play
button to operate
the simulation.
It shows the
Double Acting
Cylinder
push and pull.
Lastly, save your
wor

You might also like