Certificate of Compliance
We hereby declare that the technical file of
E-LINK ENTERPRISE
A-20, PLOT NO.8, OPP. YOGANAND TEXTILE UDHYO NAGAR,
UDHNA, SURAT-395002, GUJARAT (INDIA)
has been assessed & found to be in conformance with the provisions set forth by the requirement
of Directive Low Voltage Directive 2014/35/EU.
The Certification body has performed a sample audit of the above product quality system covering the design, manufacture & final inspection
of the certified product(s). The quality system has been assessed, approved and is subject to continuous surveillance according to Directive
General Product Safety Directive Low Voltage Directive 2014/35/EU. No additional test report was carried out from submitted type sample
of the product in Compliance with the Specification of the respective standards except those submitted by the Customer.
Date of Initial Registration 12th Aug. 2019 Issue Date 12th Aug. 2019
1st Surveillance on or before 12th Aug. 2020 Expiry Date 11th Aug. 2022
____________________
Authorized Signatory
Certificate of Compliance Appendix-I to Certificate No.: EU6014
This Appendix shall be an integral part of the Certificate. All expressions and terms defined or used in the
Certificate shall have the same meaning in this Addendum, unless the context clearly requires otherwise.
EARTHING SYSTEM
EARTHING CONDUCTIVE IMPROVEMENT METERIAL
EARTHING CHAMBER
LIGHTNING ARRESTER
The CE mark as shown can be used, under the responsibility of the manufacturer, after completion of an EC Declaration of Compliance with
all relevant EC Directives. The statement is based on a single evaluation of one sample of above mentioned product(s). This certificate is
issued under the conditions that the quality system maintained in the manufacturing of above referenced Models/Products & remains valid
until the manufacturing conditions or the quality systems are changed subject to continuous surveillance according to the EC Guidelines.
Further, Certificate is conditioned by positive results of surveillance audits.
____________________
Authorized Signatory
Scanned by CamScanner
Scanned by CamScanner
Scanned by CamScanner
Scanned by CamScanner
Scanned by CamScanner
JPl~Jrr~""""'~ # 503, Manav Niwas CHS., Plot No.7, Sector 19,
We hereby wish to inform that we have installed E- Link Make Advanced Earthing Electrode
We have installed the earthing at our site: Breach Candy Hospital, Mahalaxmi, Mumbai
The resistance values for all Earthings have been measured and found to be below 1 Ohms. We find the
results satisfactory.
.,p)~TiI ~......~ # 503. Manav Niwas CHS.• Plot No.7, Sector 19,
New Panvel • 410206. Dist. Raigad.
Phone: 27650564· Fax: 27661777
GANGESHAN ENTERPRISES E-mail: info@gangeshan.com • Web.: www.gangeshan.com
We hereby wish to inform that we have installed E- Link Make Advanced Earthing Electrode
We have installed 24 no's of Earthing at our site: Interface Building No 16. Mindspace, Malad West.
The resistance values for all Earthings have been measured and found to be below 1 Ohms. We find the
results satisfactory.
We hereby wish to inform that we have installed E- Link Make Advanced Earthing Electrode
We have installed the earthing at our site: Breach Candy Hospital, Mahalaxmi, Mumbai
The resistance values for all Earthings have been measured and found to be below 1 Ohms. We find the
results satisfactory.
.,p)~TiI ~......~ # 503. Manav Niwas CHS.• Plot No.7, Sector 19,
New Panvel • 410206. Dist. Raigad.
Phone: 27650564· Fax: 27661777
GANGESHAN ENTERPRISES E-mail: info@gangeshan.com • Web.: www.gangeshan.com
We hereby wish to inform that we have installed E- Link Make Advanced Earthing Electrode
We have installed 24 no's of Earthing at our site: Interface Building No 16. Mindspace, Malad West.
The resistance values for all Earthings have been measured and found to be below 1 Ohms. We find the
results satisfactory.
Scanned by CamScanner
E‐ LINK EARTHING
Customer List
GAIL ( India ) Limited
RMC Readymix India (Prism Cement Ltd.)
Ultratech Cement Limited
Shree Rama Newsprint Ltd.
Ammann Apollo Ltd.
Soleil Pharma
D‐ Mart
Dominoz’s Pizza
Breach Candy Hospital
Shree Krishna Hospital
Kiran Gems Pvt. Ltd
Avadh Infra Project
White Wings
Ravani Builders
Rajhans Group
Riddhi Siddhi Devlopers
Bhagyarekha Engitech Pvt. Ltd.
Bhavin Industries
C.G. Patel Institute Of Technology
Crystal Interior Products Ltd
Dirgh Diamond Pvt. Ltd.
Gangotri Corporation
Global Syntex
Imperial Indutries
J.B. Syntex Pvt. Ltd.
Jai Mahavir Prints Pvt Ltd
Karimabad Co. Dp. Housing Soc.
Maruti Plastic
Nahata Developers Pvt. Ltd (Raj Point)
Peacock Digital Print
Quality Packaging
Right Industries
Samkit Associatas
Sanskriti Packaging Pvt. Ltd.
Sarvam Polymers
Shree Khedut Sahakari Khand Udyog Mandli Ltd
Shree Narayan Corporation
Swastik Value Addition Pvt. Ltd.
The Vintage Restaurant
Venus Mills PVT LTD
AND ADDING MANY MORE…….
Scanned by CamScanner
Scanned by CamScanner
Scanned by CamScanner
Scanned by CamScanner
Scanned by CamScanner
Scanned by CamScanner
E – LINK ADVANCED EARTHING
TECHNICAL COMPARISON
Sr.
“E Link” Advanced Earthing Traditional Earthing
No
1 Dual Electrode Technology, there are One G.I /C.I. pipe of particular diameter.
two electrode, one inside the other i.e.,
Outer side pipe, inside strip
technology
2 Inner Electrode is not in direct contact The earth electrode is in direct contact
with the soil. with the soil.
3 Corrosion Resistive system Liable to fast corrosion, subsequent decay
of earthing pipe/plate.
4 Fluctuation of Ohmic value is less. Fluctuation of Ohmic value is more,
results in frequent maintenance of
gadgets / machines and may endanger
human life too.
5 Since E‐Link Electrode is surrounded Distribution of short circuit current is less
by highly conductive soil so the charge in terms of charge dissipation therefore it
dissipation through the electrode is generates high potential at the pit which
very high and the current density result in low fault current in comparison
across the electrode is very low which to required tripping circuit of fault
results in very high fault current, that protection.
is sufficient to trip the fault relays.
9 It requires less space and time to It requires a large space and time to
install the earthing electrode. install the earthing electrode.
APPLICATION OF PRODUCT
Recommendation
Sr. No. Application Earthing Type
QTY Type
* It is always better & safe to earth the Neutral even if earthing is provided for that by the power
supplier
* The above information is given in general. The selection of earth electrode (Dia and Length) &
quantity of earth pits for a particular application depends on various factors like soil resistivity of the
area, equipments to be earthed, the amount of maximum fault current that can flow in to the
electrical circuit at any given time etc. Therefore it is suggested to consult a qualified electrical
engineer / consultant before going for electrical earthing.
E – Link Earthing
Installation Method
Once installed properly the E – Link Earthing Electrode will give a very good
earth resistivity value compared to the conventional earthing and since this earthing
electrode resists the corrosion, the earth value will remain same with out much
fluctuation. This earthing system does not require any maintenance in normal soil
conditions except few buckets of watering during very hot summer season. If it is
installed properly as per our specification then it will show better result than conventional
earthing system for many years.
However, it is important to note that characteristics of the soil play a major role in
determining the earth resistance value and the factors that determines the
characteristics / resistivity of the soil is given below.
The installation method is pasted on each & every earth electrode supplied by us.
However, the E –Link Advance Earthing can be installed by any one of the following
methods depending on the soil condition.
Normal Soil:
Make a bore of 8” to 10” in diameter manually up to the electrode length (2 Mtr or 3 Mtr).
Put a little quantity of Earth Conductivity Improvement Compound – ECIM (a layer of
min. 3 to 4 inch) in side the pit and drop the electrode exactly in the center of the pit.
Now mix the soil that has been dug out with the ECIM. like sand & cement. Now pour the
above mixture in small quantity in to the pit followed by water and remove the trapped air
inside the pit by poking a rod in to the mixture repeatedly.
Repeat the above exercise till the pit is completely filled up. Pour sufficient water so that
mixture is in paste /mud form. Allow the pit to absorb the water and becomes compact.
Test the earth pit and connect to the electrical circuit. Avoid excess watering. Do not
hammer the earth electrode.
Sandy Soil:
Please make a big pit of 10’ x 10’ and 11’ deep; fill the entire pit with black cotton soil or
normal soil, pour enough water so that pit is full with water, leave it for three days so that
soil soaks up the water.
You will notice that soil level has gone down and again top up the pit with soil & fill the
water. Now after two or three days this pit is ready for earthing purpose and our earthing
can be installed there by above described normal method, that will definitely give you a
very good earth resistivity value.
However, if the pit is filled with ECIM mix soil then that will show better earth resistance
value. These types of installations may needs regular watering after certain intervals that
depends on the characteristics of the soil. It is to be noted that more than one earth
electrode may be required to be installed and connected in parallel to bring down the
earth resistance value with in safe limits.
Semi-Rocky Soil:
If enough soil is there then earthing can be done by normal method otherwise that can
be done by making a big pit as in case of sandy soil. Ours is a corrosion resistant, long
life and almost maintenance free earthing system in normal soil conditions & if installed
properly it will give better earth resistivity value than conventional earthing system. It is a
Fit & Forget earthing system. However, these types of installations may needs regular
watering after certain intervals that depends on the characteristics of the soil. It is to be
noted that more than one earth electrode may be required to be installed and connected
in parallel to bring down the earth resistance value with in safe limits.
E - LINK ENTERPRISE
TECHNO SERIES, MODEL : PRIME
DUAL ELECTRODE TECHNOLOGY
Electrode Data
Sr. No. Model No. Length
Outer Inner
Pipe Strip
GALVENISED MODEL
1 ECIM PRIME 15
2 ECIM PRIME 25
E - LINK ENTERPRISE
ALPHA SERIES, MODEL : SMART
DUAL ELECTRODE TECHNOLOGY
Electrode Data
Sr. No. Model No. Length
Outer Inner
Pipe Strip
GALVENISED MODEL
48 mm DIA
2 ELDCS1 - 502 2 MTR. 32*6
3.2 MM Thickness
1 ECIM SMART 15
2 ECIM SMART 25
E - LINK ENTERPRISE
ADVANCED EARTHING SYSTEM
CU COATED CARBON STEEL ROD TECHNOLOGY (100 and 250 Micron)
Length Dia
Sr. No. Model No.
MM MM
1 ECIM PRIME 15
2 ECIM PRIME 25
1 ECIM SMART 15
2 ECIM SMART 25
1 ECIM STAR 15
2 ECIM STAR 25