__________ 1. These tools are made of steel hardened and tempered at the tip used to loosen or tighten screws with
slotted heads.
A. Screw Driver B. Hammer C. Pliers D. Clamps
__________ 2. It is a device inserted to a convenience outlet.
A. Switch B. Fuse C. Lamp Holder D. Male Plug
__________ 3. It Is also called as lamp socket or receptacle.
A. Switch B. Fuse C. Lamp Holder D. Male Plug
__________ 4. It is a device that connects and disconnects the flow of the electric current in a circuit.
A. Switch B. Fuse C. Lamp Holder D. Male Plug
__________ 5. It is a circuit protective device that automatically blows and cuts the current when overload or short
circuits happens.
A. Circuit Breaker B. Fuse C. Junction BoxD. Switch
__________ 6. It is a protective device used to automatically blow and cut the current when trouble in the circuit or
overload occur.
A. Circuit Breaker B. Fuse C. Junction BoxD. Switch
_________ 7. It is a rectangular shaped metallic or plastic PVC material in which flush type convenience outlet
and switch are attached.
A. Utility box B. Junction BoxC. Circuit Breaker D. Conduit
_________ 8. An octagonal shaped electrical material where the connections or joints of wires are being done.
A. Utility box B. Junction Box C. Circuit Breaker D. Conduit
_________ 9. It is made of multiple strand of copper.
A. Conduit B. PVC C. Stranded Wire D. Solid Wire
_________ 10. It is made of a single strand of wire.
A. Conduit B. PVC C. Stranded Wire D. Solid Wire
_________ 11. It is used to hold and anchor electrical conduits.
A. Solid wire B. Connectors C. Clamp D. Switch
_________ 12. It is a device that act as a convenient source of electrical energy for current consuming appliances.
It is where male plug is inserted.
A. Solid Wire B. Convenience outlet C. Male Plug D. Switch
_________ 13. Duplex stranded wire use for temporary wiring installation and commonly used in extension cord
assembly.
A. Solid Wire B. Connector C. Fuse D. Flat Cord
_________ 14. It is used to drive screws with a single slot head.
A. Pliers B. Conduit C. Standard Screw Driver D. Phillip Screw Driver
_________ 15. This is used to drive screws with cross slot heads.
A. Pliers B. Conduit C. Standard Screw Driver D. Phillip Screw Driver
_________ 16. A short shank or blade and a shorted handle screw driver.
A. Allen S. D. B. Phillip S. D. C. Stubby S. D.D. Screw Driver
_________ 17. It is used for cutting, twisting bending, holding and gripping wires and cables.
A. Screw Driver B. Hammer C. Pliers D. Connector
_________ 18. It is used for gripping, holding, and cutting fine medium and big wires.
A. Long nose Pliers B. Screw DriverC. Electricians Knife D. Combination Plier
_________ 20. It is used for cutting and holding fine wires. This can reach tight spaces or small openings.
A. Long nose Pliers B. Screw DriverC. Electricians Knife D. Combination Plier
_________ 21. It is a type of pliers that can be used for cutting fine, medium, and big wires.
A. Side Cutting Pliers B. Screw DriverC. Electricians Knife D. oolCombination Plier
_________ 22. A tool for removing insulation of medium-sized wire.
A. Electricians Knife B. Wire Stripper C. Hammer D. Hacksaw
_________ 23. It is a small drilling machine.
A. Drill bit B. Welding Machine C. Portable Electric Drill D. Automatic Machine
_________ 24. It is a tool used to cut metal conduit.
A. Drill bit B. Hacksaw C. Portable Electric Drill D. Automatic Machine
_________ 25. A kind of joint commonly used to join two or more conductors inside the junction box.
A. Rat Tail B. Knotted Tap C. Y-Splice D. Duplex Cross Joint.
_________ 26. It is used where the tap wire is under considerable tensile stress.
A. Rat TailB. Knotted Tap C. Y-Splice D. Duplex Cross Joint.
_________ 27. Used for temporary tap.
A. Rat Tail B. Knotted Tap C. Aerial Tap D. Duplex Cross Joint.
_________ 29. Used when the tap wire is under considerable tensile stress,
A. Plain Tap B. Knotted Tap C. Y-Splice D. Duplex Cross Joint.
_________ 30. It is most widely used splice or joint in interior wiring.
A. Rat TailB. Western Union Short Tie C. Y-Splice D. Western Union Long Tie