You are on page 1of 12

SRI LANKA STANDARD

NA to SLS EN 1992-1-2:2013

SRI LANKA NATIONAL ANNEX TO


EUROCODE 2: DESIGN OF CONCRETE
STRUCTURES —
PART 1-2: GENERAL RULES — STRUCTURAL FIRE DESIGN

Licensed by SLSI to Urban development Authority


2022-06-28
SRI LANKA STANDARDS INSTITUTION
Single-user licence only, copying and networking prohibited.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
SRI LANKA NATIONAL ANNEX TO
EUROCODE 2: DESIGN OF CONCRETE STRUCTURES —
PART 1-2: GENERAL RULES — STRUCTURAL FIRE DESIGN

NA to SLS EN 1992-1-2:2013

Gr. 3

Copyright Reserved
SRI LANKA STANDARDS INSTITUTION
17, Victoria Place
Elvitigala Mawatha
Colombo 8
Sri LankaAuthority
Licensed by SLSI to Urban development
2022-06-28
Single-user licence only, copying and networking prohibited.
Sri Lanka Standards are subject to periodical
revision in order to accommodate the progress
made by industry. Suggestions for improvement
will be recorded and brought to the notice of the
Committees to which the revisions are
entrusted.

This standard does not purport to include all the


necessary provisions of a contract. 

©  SLSI 2013

All right reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any
form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in
writing from the SLSI.

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
Committee responsible for this National Annex

The preparation of this National Annex was entrusted by Committee SC35/WG/12, upon which the following
bodies were represented:

Eng. S A Karunarathne (Chairman) - The Society of Structural Engineers , Sri Lanka


Eng. H Abeyruwan - University of Peradeniya, Department of Civil Engineering
Eng. G T R de Silva - The Institution of Engineers, Sri Lanka
Eng. W M D N Ranasinghe - Provincial Engineering Organization – Western Province
Eng. (Prof) S M A Nanayakkara - University of Moratuwa, Department of Civil Engineering
Eng. K L S Sahabandu - Central Engineering Consultancy Bureau
Eng. (Dr) H Sooriyarachchi - University of Ruhuna, Department of Civil and Environmental
Engineering

  Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
 

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
NA to SLS EN 1992-1-2:2013

NATIONAL ANNEX TO
EUROCODE 2 : DESIGN OF CONCRETE STRUCTURES–
PART 1-2 : GENERAL RULES – STRUCTURAL FIRE DESIGN

INTRODUCTION

This National Annex has been prepared by the Working group on the development of the National
Annexes to Euro Codes (SC35/WG/12), structural use of concrete. It is to be used in conjunction with SLS
EN 1992-1-2:2012.

This National Annex was approved by the Sectoral Committee on Building and Construction Materials and
was authorized for adoption and publication as a Sri Lanka National Annex by the Council of the Sri Lanka
Standards Institution on 2013-10-02.

NA.1 SCOPE

This National Annex gives:


a) the Sri Lanka decisions for the Nationally Determined Parameters described in the following
subclasses of SLS EN 1992-1-1:2013;
— 2.1.3(2) — 5.3.2(2)
— 2.3(2)P — 5.6.1(1)
— 3.2.3(5) — 5.7.3(2)
— 3.2.4(2) — 6.1(5)
— 3.3.3(1) — 6.2(2)
— 4.1(1)P — 6.3(1)
— 4.5.1(2) — 6.4.2.1(3)
— 5.2(3) — 6.4.2.2(2)

NA.2 NATIONALLY DETERMINED PARAMETERS

Sri Lanka decisions for the Nationally Determined Parameters described in


SLS EN 1992-1-1:2012 are given in Table NA.1.

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.

NA to SLS EN 1992-1-2:2013

TABLE NA.1 – Sri Lanka decisions for Nationally Determined Parameters described in SLS EN 1992-1-2:2012

Sub clause Nationally Determined Parameter Euro code recommendation Sri Lanka decision
2.1.3 (2) Values of ∆θ1 and ∆θ2 ∆θ1 = 200 K Use the recommended values
∆θ1 = 240 K
2.3 (2)P Partial safety factor γMfi 1.0 for both thermal and mechanical properties Use the recommended value
3.2.3 (5) Values for the parameters of the stress- Class N (Table 3.2a) or Class X (Table 3.2b) Class N (Table 3.2a)
strain relationship of reinforcing steel at
elevated temperatures
3.2.4 (2) Values for the parameters of the stress- Class A or Class B in Table 3.3 Class A
strain relationship of cold worked (wires
and strands) pre stressing steel at elevated
temperatures
3.3.3 (1) Value of thermal conductivity λc Limits defined in 3.3.3 (2) The lower limit defined in 3.3.3 (2)
4.1 (1)P Use of advanced calculation methods to None None
satisfy 2.4.1 (2)P
4.5.1 (2) Value of moisture content к% below which 3% Use the recommended value
spalling is unlikely to occur
5.2 (3) Reference load level ŋfi 0.7 Use the recommended value
5.3.1 (1) Tabulated data for unbraced structures None None
5.3.2 (2) Value of emax 0.15 h (or b) Use the recommended value
5.6.1 (1) Web thickness Class WA, WB or WC WA
5.7.3 (2) Additional rules on rotation capacity at None None
supports for continuous solid slabs
6.1 (5) Reduction of strength at elevated For C55/67 and C60/75:Class 1 of Table 6.1N Use the recommended classes and
temperature for high strength concretes For C70/85 and C80/95:Class 2 of Table 6.1N value
For C90/105 : Class 3 of Table 6.1N
6.2 (2) Methods to control spalling of high strength Methods A to D Any of the Methods A to D or a
concretes combination of the methods may be
used

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
NA to SLS EN 1992-1-2:2013

TABLE NA.1 – Sri Lanka decisions for Nationally Determined Parameters described in SLS EN 1992-1-2:2012 (continued)

Sub clause Nationally Determined Parameter Euro code recommendation Sri Lanka decision
6.3 (1) Value of thermal conductivity for high Limits given in 3.3.3 (2) The upper limit defined in 3.3.3 (2)
strength concrete
6.4.2.1 (3) Value of factor k 1.1 for Class 1 of Table 6.1N Use the recommended values
1.3 for Class 2 of Table 6.1N
6.4.2.2 (2) Value of factor k m k m Values given in Table 6.2N Use the recommended values

5
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
 

 
 

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.
 

 
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
 

Licensed by SLSI to Urban development Authority


2022-06-28
Single-user licence only, copying and networking prohibited.

You might also like