Professional Documents
Culture Documents
NA to SLS EN 1992-3:2016
UDC 624.953:692.5
NA to SLS EN 1992-3:2016
Gr.2
Copyright Reserved
SRI LANKA STANDARDS INSTITUTION
No. 17, Victoria Place
Elvitigala Mawatha
Colombo 08
SRI LANKA
Sri Lanka Standards are subject to periodical
revision in order to accommodate the progress
made by industry. Suggestions for
improvement will be recorded and brought to
the notice of the Committees to which the
revisions are entrusted.
© SLSI 2016
All right reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any
form or by any means, electronic or mechanical, including photocopying and microfilm, without permission in
writing from the SLSI.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
Committee responsible for this National Annex
The preparation of this National Annex was entrusted by Committee SC35/WG/12, upon which
the following bodies were represented:
INTRODUCTION
This National Annex has been prepared by the Working group on the development of the National
Annexes to Euro Codes (SC35/WG/12), design of concrete structures. It is to be used in
conjunction with SLS EN 1992-3 : 2012.
This National Annex was approved by the Sectoral Committee on Building and Construction
Materials and was authorized for adoption and publication as a Sri Lanka National Annex by the
Council of the Sri Lanka Standards Institution on 2016-05-26.
In the preparation of this National Annex, the assistance derived from the publication of the
British Standards Institution (BSI), the European Committee for Standardization (CEN) and the
Construction Industry Research and Information Association (CIRIA) is gratefully acknowledged.
NA.1 SCOPE
a) the Sri Lanka decisions for the Nationally Determined Parameters described in the
following sub clauses of SLS EN 1992-3: 2012:
- 7.3.1 (111)
- 7.3.1 (112)
- 7.3.3
- 8.10.1.3 (103)
- 9.11.1 (102)
7.3.1(111) Values of wk1 For hD/h ≤ 5, wk1 = 0.2 mm Use the recommended
For hD/h ≥ 35, wk1 = 0.05 mm values
For intermediate values of hD /h linear
interpolation between 0.2 and 0.05 may
be used
7.3.1 (112) Value of xmin The lesser of 50 mm or 0.2h where h is Use the recommended
the element thickness values
7.3.3 Maximum bar Figure 7.103N and Figure 7.104N Use the recommended
diameter and values
bar spacing
SLS EN 1992-3: 2012, Annex K should not be used. PD 6687-1 [1] includes an alternative
informative annex which should be used instead.
CIRIA Report C660 Early-age thermal crack control in concrete [2] provides further
complementary guidance on the control of early thermal cracking.
Bibliography:
1. PD 6687-1 ,Back ground paper to the UK National Annexes to Euro code 2,Parts 1 and 2
2. CIRIA, Early-age thermal crack control in concrete.
Report C660, CIRIA, 2007
0
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.
Licensed by SLSI to Urban development Authority
2022-06-28
Single-user licence only, copying and networking prohibited.