You are on page 1of 22

29/12/2022 1

Submittal AM140JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM140JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 50.00 (MCA)
MFA [A] 63.00
Performance HP 14.00
Cooling [kW] 40.00
Cooling [Btu/h] 136,500
Heating [kW] 45.00
Heating [Btu/h] 153,500

Specifications
EER 4.72
COP 4.90
Power Input Cooling 1 [kW] 8.47
Heating 2 [kW] 9.18
Current Input (Nominal) Cooling 1 [A] 24.70
Heating 2 [A] 26.80 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) (5.09x2) Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 2200 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
7.70
Controls
Installation Max. Distance Length [m] 200 The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 255 Refrigerant System
Output [CFM] The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
9005
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 12.70 Other Features
Liquid Pipe (Φ, inch) Asymmetrical scroll design with rotating compressor operation/priority (where
1/2"
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes,
Gas Pipe (Φ, inch) 1 1/8" maximum duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are
Discharge (Φ,mm) - considered oil recovery cycles). Oil recovery operation shall not interrupt heating or
Discharge (Φ,inch) - cooling operation.
Sound Sound Pressure 61.0
Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
activation or manual activation (with MIM-B14).
Sound Power 81.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 290.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 309.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,695 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,887 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
Operating Cooling [°C] -5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0 Energy savings options to reduce system energy consumption when average indoor
room temperatures are greater than average indoor set temperatures in heating mode
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. or when average indoor room temperatures are lower than average indoor set
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. temperatures in cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to
change without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal AM140JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal AM200JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM200JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 73.00 (MCA)
MFA [A] 90.00
Performance HP 20.00
Cooling [kW] 56.00
Cooling [Btu/h] 191,100
Heating [kW] 63.00
Heating [Btu/h] 215,000

Specifications
EER 4.89
COP 4.96
Power Input Cooling 1 [kW] 11.45
Heating 2 [kW] 12.70
Current Input (Nominal) Cooling 1 [A] 33.40
Heating 2 [A] 37.00 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) - Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 5600 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
8.40
Controls
Installation Max. Distance Length [m] 200 The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 265 Refrigerant System
Output [CFM] The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
9358
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 15.88 Other Features
Liquid Pipe (Φ, inch) Asymmetrical scroll design with rotating compressor operation/priority (where
5/8"
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes,
Gas Pipe (Φ, inch) 1 1/8" maximum duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are
Discharge (Φ,mm) - considered oil recovery cycles). Oil recovery operation shall not interrupt heating or
Discharge (Φ,inch) - cooling operation.
Sound Sound Pressure 65.0
Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
activation or manual activation (with MIM-B14).
Sound Power 87.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 298.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 317.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,695 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,887 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
Operating Cooling [°C] -5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0 Energy savings options to reduce system energy consumption when average indoor
room temperatures are greater than average indoor set temperatures in heating mode
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. or when average indoor room temperatures are lower than average indoor set
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. temperatures in cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to
change without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal AM200JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal AM220JXVAFH/AZ DVM S Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM220JXVAFH/AZ
Features Type DVM S
Power Voltage [Φ, #, V, Hz] 3,3,208-230,60
MCA [A] 70.00 (MCA)
MFA [A] 80.00
Performance HP 22.00
Cooling [kW] 61.60
Cooling [Btu/h] 210,200
Heating [kW] 69.30
Heating [Btu/h] 236,500

Specifications
EER 3.85
COP 4.40
Power Input Cooling 1 [kW] 16.00
Heating 2 [kW] 15.75
Current Input (Nominal) Cooling 1 [A] 46.65
Heating 2 [A] 45.93 Compatibility
System Mode HEAT PUMP NASA DVM S indoor units , AHU kits (MXD-K***AN), and UCK (MCM-D211UN)
Compressor Type Construction
SSC Scroll x 2
The unit shall be galvanized steel with a baked on powder coated finish.
Output (kW x n) - Heat Exchanger
Oil Type PVE The heat exchanger shall be mechanically bonded fin to copper tube.
Inicial Charge [cc] 5600 The aluminum fins of the heat exchanger shall have a protective coating.
Refrigerant Type R410A Salt spray test method: ASTM-B117-18 - the heat exchanger showed no unusual rust or
Factory Charge [kg] corrosion development to 2,280 hours.
12.50
Controls
Installation Max. Distance Length [m] 200 The outdoor unit shall have a removable EEPROM that stores unit serial number, startup
Height [m] 110.0 information, system settings, system tag/name, and other information.
Condenser Fan Fan Type Propeller Control wiring shall be 16 AWG X 2 shielded wire.
Output [CMM] 340 Refrigerant System
Output [CFM] The compressors shall be Samsung hermetically sealed, inverter driven, direct flash
12007
injected, DC scroll type with soft-start capability.
Motor Output [W] 620.0 x 2
Flash injected compressors provide advanced low ambient heating performance.
E.S.P Max. [mmAq] 8.00 Subcooling devices in system maintain capacity at extreme system refrigerant pipe
E.S.P Max. [Pa] 78.45 lengths and minimize refrigerant noise.
Piping Connections Liquid Pipe (Φ, mm) 15.88 Other Features
Liquid Pipe (Φ, inch) Asymmetrical scroll design with rotating compressor operation/priority (where
5/8"
applicable).
Gas Pipe (Φ, mm) 28.58
Advanced oil recovery cycle logic (maximum duration in cool mode: 3 minutes,
Gas Pipe (Φ, inch) 1 1/8" maximum duration in heat mode: 6 minutes, defrost cycles lasting over 3 minutes are
Discharge (Φ,mm) - considered oil recovery cycles). Oil recovery operation shall not interrupt heating or
Discharge (Φ,inch) - cooling operation.
Sound Sound Pressure 66.0 / 69.0
Optional night quiet modes to reduce outdoor unit sound (4 levels) with automatic
activation or manual activation (with MIM-B14).
Sound Power 87.0
Advanced intelligent defrost logic to significantly reduce defrost cycle frequency by
Dimension Net Weight(kg) 333.0 monitoring air resistance across the condenser coil during heating operation to
Shipping Weight (kg) 355.0 determine defrost operation initiation to prevent unnecessary defrost cycles.
Net Dimensions (WxHxD) (mm) 1,295 x 1,795 x 765 Optional snow blowing logic to prevent snow accumulation on idle outdoor units
Shipping Dimensions (WxHxD) (mm) 1,363 x 1,987 x 832 Maximum current control of outdoor unit(s) to limit current (50% - 100% of design
current) adjustable at outdoor unit or central control devices: DMS 2.5 (MIM-D01AN),
Operating Cooling [°C] -5.0 ~ 48.0
Temp. Range BACnet Gateway (MIM-B17BN), LON Gateway (MIM-B18BN).
Heating [°C] -25.0 ~ 24.0 Energy savings options to reduce system energy consumption when average indoor
room temperatures are greater than average indoor set temperatures in heating mode
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. or when average indoor room temperatures are lower than average indoor set
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB. temperatures in cooling mode.
Samsung maintains a policy of ongoing development, specifications are subject to
change without notice.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal AM220JXVAFH/AZ DVM S Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal AM012NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM012NNNDCH/AA
Features Type Wind-Free 4Way Cassette
(600x600)
Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60
Capacity Cooling [kW]

Specifications
3.52
Cooling [Btu/h] 12,000
Heating [kW] 3.96
Heating [Btu/h] 13,500 •Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
Current Input (Nominal) Cooling 1 [A] 0.19 systems (AM**********/**).
Heating 2 [A] 0.19
•Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR
fascia panel)
Power Input (Nominal) Cooling 1 [W] 28.00
Heating 2 [W] 28.00 •Built in condensate pump with maximum 29" lift from the bottom of
Fan Type Turbo Fan the unit, check valve, and float switch that disables indoor unit during
Motor (Output) [W] overflow detection
65 x 1
Air Flow Rate (High / Mid / Low) [CFM] 371/336/283
•Knock-out for outside air capability
Air Flow Rate (High / Mid / Low) [CMM] 10.51/9.51/8.01
Air Flow Rate (High/Mid/Low) [L/S] 175.09/158.57/133.56 •Fascia panel shall have LED indicator lights and 4 motorized louvers
External Static Pressure (Min / Std / Max) [in H20] - with independent control (32° - 65° louver control range)
External Static Pressure (Min / Std / Max) [mmAq] -
•High-voltage terminal block temperature sensor to disable unit in the
External Static Pressure (Min / Std / Max) [Pa] -
event overheating of power connection.
Piping Connections Liquid Pipe (Φ, mm) 6.35
Liquid Pipe (Φ, inch) 1/4" •Wind-Free™ function will close the supply air outlet louver while in
Gas Pipe (Φ, mm) 12.70 cooling mode to gently disperse cool air into the space without
Gas Pipe (Φ, inch) 1/2" blowing directly onto occupants. The Wind-Free™ feature is optional
Drain Pipe (Φ,mm) and can be enabled using central or local control options (MWR-
VP25 (OD 32,ID 25)
SH11N, MWR-WE13N, MWR-WE13N, MWR-WG00*N, and AR-EH03U
Field Wiring Power Source Wire AWG 14 only).
Transmission Cable 2 X 16 AWG SHIELDED
Refrigerant Type R410A •The Wind-Free™ 4-way cassette can be configured for 2-stage
Control Method EEV INCLUDED operation, cooling the space with the louver open (fixed or swing) until
Sound Sound Pressure the room temperature nears set temperature. Once room temperature
34.0/30.0/26.0
is near set temperature, Wind-Free™ operation will start automatically,
Sound Power 51.0
closing the louver and using the face of the fascia panel to gently cool
External Dimension (Indoor Unit) Net Weight(kg) 12.00 the space with still air*.
Shipping Weight (kg) 14.00
Net Dimensions (WxHxD) (mm) 575 x 250 x 575 •The Wind-Free™ panel (PC4NUFMUN) has an integral humidity sensor
Shipping Dimensions (WxHxD) (mm) 623 x 298 x 653
that will open the louvers for standard cool mode when space
conditions could potentially cause condensation formation on the
Panel Size Panel model PC4SUSMUN
panel surface.
Panel Net Weight (kg) 2.30
Shipping Weight (kg) 3.50 Construction
Net Dimensions (WxHxD) (mm) 620 x 45 x 620 Insulated, HIPS chassis with a galvanized steel frame and fascia panel
Shipping Dimensions (WxHxD) (mm) 661 x 106 x 671 certified to UL94 V0.
Additional Accessories Drain Pump -
Heat Exchanger
Drain Pump Max. Lifting Height/Displacement - The heat exchanger shall be mechanically bonded fin to copper tube
Air Filter Removable / Washable Indoor Fan
Indoor fan is a single turbo type
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. Three fan speed settings and auto setting
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.
Controls

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal AM012NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal AM018NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM018NNNDCH/AA
Features Type Wind-Free 4Way Cassette
(600x600)
Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60
Capacity Cooling [kW]

Specifications
5.28
Cooling [Btu/h] 18,000
Heating [kW] 5.86
Heating [Btu/h] 20,000 •Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
Current Input (Nominal) Cooling 1 [A] 0.27 systems (AM**********/**).
Heating 2 [A] 0.27
•Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR
fascia panel)
Power Input (Nominal) Cooling 1 [W] 36.00
Heating 2 [W] 36.00 •Built in condensate pump with maximum 29" lift from the bottom of
Fan Type Turbo Fan the unit, check valve, and float switch that disables indoor unit during
Motor (Output) [W] overflow detection
65 x 1
Air Flow Rate (High / Mid / Low) [CFM] 459/388/336
•Knock-out for outside air capability
Air Flow Rate (High / Mid / Low) [CMM] 13.00/10.99/9.51
Air Flow Rate (High/Mid/Low) [L/S] 216.62/183.11/158.57 •Fascia panel shall have LED indicator lights and 4 motorized louvers
External Static Pressure (Min / Std / Max) [in H20] - with independent control (32° - 65° louver control range)
External Static Pressure (Min / Std / Max) [mmAq] -
•High-voltage terminal block temperature sensor to disable unit in the
External Static Pressure (Min / Std / Max) [Pa] -
event overheating of power connection.
Piping Connections Liquid Pipe (Φ, mm) 6.35
Liquid Pipe (Φ, inch) 1/4" •Wind-Free™ function will close the supply air outlet louver while in
Gas Pipe (Φ, mm) 12.70 cooling mode to gently disperse cool air into the space without
Gas Pipe (Φ, inch) 1/2" blowing directly onto occupants. The Wind-Free™ feature is optional
Drain Pipe (Φ,mm) and can be enabled using central or local control options (MWR-
VP25 (OD 32,ID 25)
SH11N, MWR-WE13N, MWR-WE13N, MWR-WG00*N, and AR-EH03U
Field Wiring Power Source Wire AWG 14 only).
Transmission Cable 2 X 16 AWG SHIELDED
Refrigerant Type R410A •The Wind-Free™ 4-way cassette can be configured for 2-stage
Control Method EEV INCLUDED operation, cooling the space with the louver open (fixed or swing) until
Sound Sound Pressure the room temperature nears set temperature. Once room temperature
39.0/36.0/33.0
is near set temperature, Wind-Free™ operation will start automatically,
Sound Power 56.0
closing the louver and using the face of the fascia panel to gently cool
External Dimension (Indoor Unit) Net Weight(kg) 12.00 the space with still air*.
Shipping Weight (kg) 14.00
Net Dimensions (WxHxD) (mm) 575 x 250 x 575 •The Wind-Free™ panel (PC4NUFMUN) has an integral humidity sensor
Shipping Dimensions (WxHxD) (mm) 623 x 298 x 653
that will open the louvers for standard cool mode when space
conditions could potentially cause condensation formation on the
Panel Size Panel model PC4SUSMUN
panel surface.
Panel Net Weight (kg) 2.30
Shipping Weight (kg) 3.50 Construction
Net Dimensions (WxHxD) (mm) 620 x 45 x 620 Insulated, HIPS chassis with a galvanized steel frame and fascia panel
Shipping Dimensions (WxHxD) (mm) 661 x 106 x 671 certified to UL94 V0.
Additional Accessories Drain Pump -
Heat Exchanger
Drain Pump Max. Lifting Height/Displacement - The heat exchanger shall be mechanically bonded fin to copper tube
Air Filter Removable / Washable Indoor Fan
Indoor fan is a single turbo type
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. Three fan speed settings and auto setting
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.
Controls

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal AM018NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal AM020NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AM020NNNDCH/AA
Features Type Wind-Free 4Way Cassette
(600x600)
Power Supply (Indoor Unit) [Φ, #, V, Hz] 1,2,208-230,60
Capacity Cooling [kW]

Specifications
5.86
Cooling [Btu/h] 20,000
Heating [kW] 6.74
Heating [Btu/h] 23,000 •Compatible with Samsung DVM S, DVM S Water, and DVM S Eco
Current Input (Nominal) Cooling 1 [A] 0.30 systems (AM**********/**).
Heating 2 [A] 0.30
•Electro-static, washable, pleated filters as standard (included with
System Mode HP/HR
fascia panel)
Power Input (Nominal) Cooling 1 [W] 38.00
Heating 2 [W] 38.00 •Built in condensate pump with maximum 29" lift from the bottom of
Fan Type Turbo Fan the unit, check valve, and float switch that disables indoor unit during
Motor (Output) [W] overflow detection
65 x 1
Air Flow Rate (High / Mid / Low) [CFM] 477/424/360
•Knock-out for outside air capability
Air Flow Rate (High / Mid / Low) [CMM] 13.51/12.01/10.19
Air Flow Rate (High/Mid/Low) [L/S] 225.11/200.10/169.90 •Fascia panel shall have LED indicator lights and 4 motorized louvers
External Static Pressure (Min / Std / Max) [in H20] - with independent control (32° - 65° louver control range)
External Static Pressure (Min / Std / Max) [mmAq] -
•High-voltage terminal block temperature sensor to disable unit in the
External Static Pressure (Min / Std / Max) [Pa] -
event overheating of power connection.
Piping Connections Liquid Pipe (Φ, mm) 6.35
Liquid Pipe (Φ, inch) 1/4" •Wind-Free™ function will close the supply air outlet louver while in
Gas Pipe (Φ, mm) 12.70 cooling mode to gently disperse cool air into the space without
Gas Pipe (Φ, inch) 1/2" blowing directly onto occupants. The Wind-Free™ feature is optional
Drain Pipe (Φ,mm) and can be enabled using central or local control options (MWR-
VP25 (OD 32,ID 25)
SH11N, MWR-WE13N, MWR-WE13N, MWR-WG00*N, and AR-EH03U
Field Wiring Power Source Wire AWG 14 only).
Transmission Cable 2 X 16 AWG SHIELDED
Refrigerant Type R410A •The Wind-Free™ 4-way cassette can be configured for 2-stage
Control Method EEV INCLUDED operation, cooling the space with the louver open (fixed or swing) until
Sound Sound Pressure the room temperature nears set temperature. Once room temperature
40.0/38.0/35.0
is near set temperature, Wind-Free™ operation will start automatically,
Sound Power 57.0
closing the louver and using the face of the fascia panel to gently cool
External Dimension (Indoor Unit) Net Weight(kg) 12.00 the space with still air*.
Shipping Weight (kg) 14.00
Net Dimensions (WxHxD) (mm) 575 x 250 x 575 •The Wind-Free™ panel (PC4NUFMUN) has an integral humidity sensor
Shipping Dimensions (WxHxD) (mm) 623 x 298 x 653
that will open the louvers for standard cool mode when space
conditions could potentially cause condensation formation on the
Panel Size Panel model PC4SUSMUN
panel surface.
Panel Net Weight (kg) 2.30
Shipping Weight (kg) 3.50 Construction
Net Dimensions (WxHxD) (mm) 620 x 45 x 620 Insulated, HIPS chassis with a galvanized steel frame and fascia panel
Shipping Dimensions (WxHxD) (mm) 661 x 106 x 671 certified to UL94 V0.
Additional Accessories Drain Pump -
Heat Exchanger
Drain Pump Max. Lifting Height/Displacement - The heat exchanger shall be mechanically bonded fin to copper tube
Air Filter Removable / Washable Indoor Fan
Indoor fan is a single turbo type
* Nominal cooling capacities are based on: Indoor temperature: 80 ⁰F DB, 67⁰F WB. Outdoor temperature: 95⁰F DB, 75⁰F WB. Three fan speed settings and auto setting
* Nominal heating capacities are based on: Indoor temperature: 70 ⁰F DB, 60⁰F WB. Outdoor temperature: 47⁰F DB, 43⁰F WB.
Controls

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal AM020NNNDCH/AA Wind-Free 4Way Cassette (600x600) Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal AR-EH03E Wireless remote controller Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model AR-EH03E
Features Type Wireless remote controller

Specifications

• Multi-channel wireless control of Samsung indoor units

• Can control up to 4 indoor units individual (setup required)

• Wide display

• Soft-touch buttons

Specifications
Compatibility
• Control options: ON/OFF, set temperature, mode, fan speed, filter reminder reset, independent louver control
(AM0***N4DCH, AM0***NNDCH/**, AC0***N4DCH/**, and AJ0***NNDCH/** only), airflow direction, single event timer
• DVM S indoor units (AM0***N****/**)
setting, Wind-FreeTM Cooling and Long Reach functions (applies to supported models when using the Wind-FreeTM fascia
panel).
• Free Joint Multi (FJM) mini 4-way cassette (AJ0***NNDCH/**,
AJ0**NBNDCH/**)
• Indoor unit address and option setting programming mode

• Single zone CAC 4-way cassette systems (AC0***N4DCH/**)


• Includes holder to mount on wall

• Single zone CAC duct systems (AC0***NHDCH/**, AC0**NMDCH/**,


• Dimensions (W X L X H): 1 13/16" X 5 3/8" X 13/16"
AC0***NLDCH/**)

**Requires the installation of MRK-A10N wireless receiver kit**

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal AR-EH03E Wireless remote controller Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal MCM-A300N Touch centralized controller Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MCM-A300N
Features Type Touch centralized controller

Features
• 7" touch LCD controller
• Maximum 128 indoor units and Samsung ERV's
• Allows creation of zones for indoor unit grouping (12 maximum) with customizable zone icons
• Can connect and control up to 16 X DVM S systems (see page 2 for more details)
• 2 X digital input terminals for dry-contact connection to disable/enable all connected equipment (3 optional configuration
settings)
• 1 X digital output terminal for system operation status output, 12 VDC, 10 mA max. (short: 1 or more indoor units are ON.
Open: all indoor units are OFF)

Specifications
• SD card slot for data backup and future software updates
Specifications
Compatible with DVM S systems (AM****X****/**), DVM Chiller
Convenience
(AG0*******/**), CAC 1:1 systems (AC0********/**) without
• Scheduling (maximum 10 schedules)
additional hardware/adapters. Compatible with the following systems
• All ON/OFF button
using MIM-N01 communication interface module: FJM multi-zone
• Indoor unit operation mode, set temperature, fan speed, controller use/restriction enable/disable, louver control, and filter
systems (AJ0*****CH/**), DVM Plus III and earlier VRF models.
reminder reset setting/checking.
Compatible with Fresh Access™ ERV units (AN***NSEDAV/**) using
• Cooling and heating temperature (desired temperature) limit setting
MXD-K200VN ERV kit at every ERV and 1 X MIM-N10 ERV interface
• Group/zone control
module per 16 ERV Kits. Compatible with FCU Kit (MIM-F00N) using one
• Operation mode restriction setting
MIM-F10N FCU kit interface module per 16 FCU Kits.
• Screen lock
Maximum:
• Restrict: ON/OFF, mode, set temperature, fan speed, advanced settings, and remote control use (basic indoor unit settings)
• 64 indoor units, 1 system, and 16 MCU's when connected to F1/F2
for daily users
(system/set layer)
• Menu lock (restrict indoor unit control, schedule setting/changing, and controller settings for daily users)
• 128 indoor units and 16 systems when connected to R1/R2 (control
• LCD ON/OFF button/indicator on front of controller to turn display ON/OFF (blue indicator: 1 or more indoor units are ON.
layer)
Red indicator: indoor unit/system error is present)
100 - 240 VAC, 50/60Hz
• Option to group multiple indoor units to display as one indoor unit on user interface
RS485 communication
Can connect to R1/R2 or F1/F2 communication wires
Up to 16 X MCM-A300N controllers can connect together on R1/R2 or
F1/F2 communication line
Up to 15 X MCM-A300N controllers can connect together on R1/R2
communication line when used with MIM-D00AN, MIMD01AUN, MIM-
B17N, MIM-N17BN, MIM-B18N, and MIM-B18BN gateways
16 AWG X 2 shielded wire for all R1/R2 and F1/F2 communication
wiring

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal MCM-A300N Touch centralized controller Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal MIM-D01AN DMS 2.5 Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MIM-D01AN
Features Type DMS 2.5

Features
Easy Control & Monitoring Through Web Browser
• Individual/Group control of up to 256 indoor units
• Operation mode, temperature setting, airflow direction, fan speed, temperature restriction settings, unoccupied mode
setting, and discharge air temperature setting (for applicable duct unit models).
• Restrict use of wireless/wired remote controllers, mode, temperature, and set point.
• Outdoor and indoor unit cycle monitoring
• Convenient digital display allows for easy initial set up
• SD card slot for data storage and software updating (daily automatic backup, SD card purchased separately)

Specifications
• LAN connection for upper level control options
• Available sophisticated control logic allows programming outputs based on various system inputs
• Dynamic security management
• Operation and error history management
• Maximum current control of outdoor unit(s) to limit current (50% - 100% of design current) adjustable at outdoor unit or
MIM-D01AN (does not apply to all system models)
• Supports multiple user access (different usernames and access levels)
• Various user management level settings (HVAC system access, gateway permission access)
• Unoccupied room control settings adjustment capability (for compatible units)

Web Server Function


• Remote control with a public IP address via internet connection
• No management soft required – PC- management through web browser (optimized for Internet Explorer)
• Multiple user accounts can be setup with the ability to specify what unit(s) each individual can monitor and control and
what level of control permission is allowed.
• 2D Floorplan layout option for simplified project viewing

Schedule Control Function Through Web Browser


• Up to 256 schedule settings
• Weekly and daily schedule setting
• Wireless/wired remote controller restriction setting
• Digital outputs can be incorporated into scheduling

Advanced Programmable Control Logic Setting


• Specify various system control point inputs (indoor units, outdoor units, DI, DO) and operators (=, >, <, ≤, ≥, ≠) to
manipulate system operation (indoor units, outdoor units, DI, DO) based on the status of the specified variables.
Advanced Heat Pump Auto Changeover Logic
• Optional "weighted averaging" or "representative" setting for heat pump systems to provide optimal auto changeover while
in Auto mode.
External Contact Interface
• Full indoor unit control with simple contact input (emergency/lock)
• 8 additional digital input terminals for monitoring options
• State output (operation/error) for synchronous control
• 6 general purpose outputs to control other components (on: 12VDC out; off: no voltage)
• Digital inputs and digital outputs can be incorporated into control logic
• Digital outputs can be incorporated into control logic and daily schedules to control other devices

Energy Management / Power Distribution Function


• Ability to monitor, track, and query energy use from indoor unit(s) and systems with MIM-B16 or MIM-B16N and electricity
meter interface module (purchased separately, requires 3rd party watt-hour meters with pulse output).
• When used with SNET 3 software, detailed PDF report generation is possible
• User defined daily time periods for energy use reports to accommodate on/off peak energy billing.
• Export energy usage and other data to Excel file

History Management
• Storage of all operation commands from gateway and other system controls (saves to SD card purchased separately).
• Storage of all error events for review (saves to SD card purchased separately).
• Storage of all operation logic control events (saves to SD card purchased separately).
• Error alerts via email that contain: error code, error explanation, units affected, time and date of error occurrence, and
error status.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal MIM-D01AN DMS 2.5 Latin America

Specifications
• MIM-D01AN shall monitor status and control Samsung DVM S, CAC, FJM, RAC, ERV (MIM-N10 interface module adapter required), and DVM Chiller systems
• MIM-D01AN shall monitor status and control Samsung systems only via web client or Samsung SNET 3 software.

Specifications
• Connection of FJM and DVM Plus III equipment or earlier models will require a communication interface module adapter (MIM-N01)
• DC 12V, 3A power provided by AC/DC adapter (input 110-240VAC 50/60Hz, provided with MIM-D01AN)
• Communication connection via ON/OFF Controller(s) (MCM-A202DN) and direct connection to DVM S series (AM*********/**, AG*********/** and CAC (AC0********/**)
outdoor units
• 16 AWG X 2 shielded cable between Samsung equipment and controls is recommended for proper operation

• Maximum number of RS485 connections:


- Maximum 75 ON/OFF Controllers (MCM-A202DN) to 1 MIM-D01AN
- Maximum 15 ON/OFF Controllers (MCM-A202DN) to a single MIM-D01AN channel
- Maximum 75 Touch Central Controllers (MCM-A300N) to 1 MIM-D01AN
- Maximum 15 Touch Central Controllers (MCM-A300N) to a single MIM-D01AN channel
- Maximum 16 systems to a single channel (5 total)
- Maximum 80 systems connected direct (5 ports, 16 systems per port), 256 through ON/OFF Controllers (MCM-A202DN)
- Maximum 16 Chiller FCU Interface Modules (MIM-F10N) to a single channel (5 total, each MIM-F10N supports up to 16 MIM-F00N FCU Kits)
- Maximum 80 Chiller FCU Interface Modules (MIM-F10N) connected direct (5 ports, 16 X MIM-F10N per port)
- Maximum 128 indoor units on a single MIM-D01AN channel (HR MCU, air handlers, and Samsung ERV's)
- Maximum 256 indoor units (HR MCU, air handlers, and Samsung ERV's) to one MIM-D01AN
- Maximum 8 MIM-B16 Energy Meter Interface Modules per MIM-D01AN (must connect to CH4 (COM5) on gateway)
- Maximum 8 MIM-B16N Energy Meter Interface Modules per MIM-D01AN (can connect to same channel as DVM S outdoor units on gateway)

• Digital inputs and outputs:


- DI terminals (X 10): Dry input (0V)
- DO terminals (X 8): 12VDC, maximum 200 mA
• Refer to controls Technical Data Book for more information found at www.DVMdownload.com.

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal MWR-WG00JN Wired remote controller Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MWR-WG00JN
Features Type Wired remote controller

Features
Easy indoor unit control 1
• Air handler operation ON/OFF
• Air handler operation mode, set temperature, air flow direction, fan speed
• Discharge air temperature setting (with supported indoor unit models)
• Filter replacement alarm display and reset
• Single indoor unit control or multiple unit control (maximum 16 units)
• Time synchronization with DMS2.5 gateways
• Dual Set Temperature (indoor unit firmware upgrade may be required 2)

Specifications
• Advanced HP auto changeover control and configuration (indoor unit firmware upgrade may be required)
Specifications*
• Quiet and sleep modes
• Compatible with Samsung DVM S Systems (AM************, MCM-
• Error display (up to 10 error codes with descriptions)
D211UN), and DVM Chiller FCU Kits (MIM-F00N).
• Can connect and control up to 16 indoor units on a single system or
Energy saving operation
across multiple systems
• Upper/lower temperature restriction setting
• 2 Conductor connection
• Occupied/unoccupied settings
• DC 12V power supplied by indoor unit (consumption: 2W)
• Setback function
• PLC (power line communication) is done on F3/F4 terminals.
• Energy saving operation mode
• Can sense temperature via internal sensor, temperature sensor inside
• Energy consumption monitoring and daily, weekly, monthly, and yearly energy consumption trending (for supported
indoor unit, or use the average temperature between controller and air
systems)
handler temperature sensors
• Maximum current control for DVM S 3Ø outdoor units (AM****XV******)
• 16 AWG shielded cable is necessary for proper operation
Weekly operating schedule setting
• Weekly operating schedule
• Able to set desired A/C operation mode, setting temperature and fan speed to operate based on weekly schedules
• Able to apply schedule exception day

Other features
• Different button permission levels Supports multiple languages (English, Spanish, French, Portuguese, Dutch, German)
• Partial button lock options (operation on/off, heat mode, cool mode, fan mode, dry mode, auto mode, set temperature, fan
speed, scheduling, Wind-Free, Long-wind, quiet mode, and sleep mode buttons can be locked individually).
• Daylight savings clock advance option
• Temperature limit setting option
• Real-time clock function
• Built-in IR receiver for indoor unit control using a wireless controller and integral room temperature sensor
• Indoor unit operation state display
• Indoor unit service mode support
• Micro SD card slot for simple firmware updating
• Independent louver control for DVM S Series 4-way cassette (AM0***N4DCH/**) and mini 4-way cassette
(AM0***NNDCH/**) models
• Airflow direction control for 360 Cassette (AM0**KN4DCH/**) indoor units. 360 Cassette units manufactured before
7/1/2016 will require a firmware update to use MWR-WG00JN.
Contact Samsung HVAC technical support to obtain the firmware upgrade files. Firmware updating can be done using MIM-
C02N communication converter/service tool.
• Adjustable heating temperature compensation values
• Wind-FreeTM Control (applies to AM0**NN4DCH/**, AM0**RN4DCH/**, AM0**NNNDCH/**, and AM0**NN1DCH/**
when using the Wind-FreeTM fascia panel)
• MDS (Motion Detection Sensor) Indirect/ Direct Control (applies to AM0***N4DCH/** and AM0***NNDCH/**. MDS sold
separately).
• Long Reach Function (for applicable indoor unit models)
• Automatic air volume enable and status viewing (for Duct S models AM0**MNMDCH/**, AM0**MNHDCH/**, and
AM0**RNMDCH/**).

* Some features may not be available depending on the model of connected air handler(s)
* Firmware upgrade may be required for certain features.

English 1

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Submittal MWR-WG00JN Wired remote controller Latin America

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 1

Submittal MXJ-YA1509M Y-joint Latin America

Job Name Location


Purchaser Engineer
Submitted to Reference Approval Construction

Specifications
Model MXJ-YA1509M
Features Type Y-joint

• Required component for Samsung DVM S and DVM Eco systems (AM****X****/**) with multiple evaporators and/or
Mode Change Units (MCU)
• Constructed of brazed copper or brass and copper
• Indoor unit Y-joint models include both liquid and suction fittings, insulation, and ties to secure insulation
• Heat recovery (HR) Y-joint models are required for branching the hot gas pipe throughout heat recovery systems (HR
systems only)
• Included insulation shall be polystyrene certified to UL94 V0, 5/8" wall thickness
• Inlet pipe shall be adjustable to facilitate different pipe sizes without having to braze additional fittings
• Each model shall include adjustable reducers as noted in the table below

Specifications

English 1

Submittal MXJ-YA1509M Y-joint Latin America

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.
29/12/2022 2

Specifications

English 2

Samsung maintains a policy of ongoing development, specifications are subject to change without notice.

You might also like