Professional Documents
Culture Documents
Content Page
Product description 2
Properties and benefits 2
Sample applications 2
Handling and storage 2
Applications and intended use 3
Application in cracked Application in non-
Resin properties 3
concrete cracked concrete
Curing times 3
Application in concrete 4
Installation instruction 4
Cleaning 6
Installation parameter 7
Design values 8
Recommended loads 16
Application under seismic Post-installed rebar Fire resistance 20
loading
Chemical resistance 21
Sormat Oy
Harjutie 5
FIN-21290 Rusko, Finland
Telephone +358 (0) 207 940 200
Fax +358 (0) 201 76 3888
www.sormat.com
1
sormat@sormat.com
Rev. 10 (EN)
PRODUCT DATA SHEET
Product description
ETA The ITH EPOXe is a 2-component resin mortar based on a pure epoxy and will be deliver-
OPTION 1 ed in an exclusive 2-C cartridge system. This high performance product may be used in
combination with a hand-, battery- or pneumatic tool and a static mixer ISL EPOX(e). It was
designed especially for the anchoring of threaded rods, reinforcing bars or internal threaded
rod sleeves into concrete (also porous and light) as well as solid masonry. Based on the ex-
cellent standing behavior the usability in combination with a special plastic sleeve in hollow
material is given. The ITH EPOXe is characterised, by a huge range of applications with an
installation temperature from +5 °C and a service temperature up to 72 °C as well as by high
chemical resistance for applications in extreme ambiences e.g. in swimming pools (chlorine)
or closeness to the sea (salt). The wide range of certificates and approvals, allows nearly
every application.
Sample applications
Suitable for facades, roofs, wood construction, metal construction; metal profiles, column,
beam, console, railing, sanitary devices, cable trays, piping, post-installed rebar connection
(reconstruction or reinforcement), etc.
Rev. 10 (EN)
PRODUCT DATA SHEET
Resin properties
Properties Test Method Result
UV resistance Pass
Water tightness DIN EN 12390-8 Pass
Temperature stability 72 °C
Viscosity (A-component) ASTM D 2556 16600 mPas
Viscosity (B-component) ASTM D 2556 16400 mPas
pH-value > 12
Density 1,41 kg / dm³
Compressive strength EN 196 Part 1 120 N / mm²
Flexural strength EN 196 Part 1 42 N / mm²
E modulus EN 196 Part 1 10800 N / mm²
Shrinkage < 0,02 %
Hardness Shore D 85
Electrical resistance IEC 93 1.2 1012 Ω m
Thermal conductivity IEC 60093 0,47 W/m·K
Curing times
Temperature of base Full curing time in dry Full curing time in wet
Gel- / working time
material base material base material
+5 °C 120 min 50 h 100 h
+10 °C 90 min 30 h 60 h
+20 °C 30 min 10 h 20 h
+30 °C 20 min 6h 12 h
+40 °C 12 min 4h 8h
Rev. 10 (EN)
PRODUCT DATA SHEET
2a For diamond drilled holes rinse until clear water appears. Furthermore clean the hole
with a mechanical wire brush. After that repeat the step before (rinse until clear water
appears).
2b.Standing water must be removed before cleaning. Starting from the bottom resp.
back of the bore hole, blow the hole clean with compressed air or a hand pump a
minimum of two times. If the bore hole ground is not reached an extension shall be used.
The hand-pump can be used for anchor sizes up to bore hole diameter 20 mm. For bore
holes larger then 20 mm or deeper than 240 mm, compressed air (min. 6 bar) must be
or used.
2c.Check the correct brush diameter and brush the hole with an appropriate sized wire
brush a minimum of two times. If the bore hole ground is not reached with the brush,
a brush extension shall be used.
2d.Finally blow the hole clean again with compressed air or a hand pump a minimum
of two times. If the bore hole ground is not reached an extension shall be used. The
hand-pump can be used for anchor sizes up to bore hole diameter 20 mm. For bore holes
larger than 20 mm or deeper than 240 mm, compressed air (min. 6 bar) must be used.
or
Rev. 10 (EN)
PRODUCT DATA SHEET
4. Prior to inserting the anchor rod into the filled bore hole, the position of the embed-
ment depth shall be marked on the anchor rods.
5. Prior to dispensing into the anchor hole, squeeze out separately a minimum of three
full strokes (≥ 10 cm) and discard non-uniformly mixed adhesive components until the
mortar shows a consistent red color.
6. Starting from the bottom resp. back of the cleaned anchor hole fill the hole up to
approximately two-thirds with adhesive. Slowly withdraw the static mixing nozzle
as the hole fills to avoid creating air pockets. For embedment depth larger than 190 mm
an extension nozzle shall be used. For overhead and horizontal installation in bore holes
bigger than 20 mm a piston plug and extension nozzle shall be used. Observe the gel-/
working times given.
7. Push the threaded rod or reinforcing bar into the anchor hole while turning slightly to
ensure positive distribution of the adhesive until the embedment depth is reached.
The anchor should be free of dirt, grease, oil or other foreign material.
8. Be sure that the anchor is fully seated at the bottom of the hole and that excess mortar
is visible at the top of the hole. If these requirements are not maintained, the applica-
tion has to be renewed.
9. Allow the adhesive to cure to the specified time prior to applying any load or torque.
Do not move or load the anchor until it is fully cured.
10.After full curing, the add-on part can be installed with the max. torque by using a
calibrated torque wrench.
Rev. 10 (EN)
PRODUCT DATA SHEET
Blower
Piston plug
Threaded rod Rebar Bore hole-Ø Brush-Ø Min. brush-Ø Piston plug
Rev. 10 (EN)
PRODUCT DATA SHEET
Anchor size (threaded rod) M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Edge distance Ccr,N [mm] 113 135 165 188 255 304 342 379 400 436 472
Min. edge distance Cmin [mm] 40 50 60 80 100 120 135 150 165 180 195
Spacing Scr,N [mm] 226 270 330 375 510 607 683 759 799 872 945
Min. spacing Smin [mm] 40 50 60 80 100 120 135 150 165 180 195
Embedment depth hef [mm] 80 90 110 125 170 210 250 280 320 350 380
Min. base material
hmin [mm] hef + 30 mm hef + 2d0
thickness
Anchor diameter d [mm] 8 10 12 16 20 24 27 30 33 36 39
Drill diameter d0 [mm] 10 12 14 18 24 28 32 35 37 42 46
Installation torque Tinst [Nm] 10 20 40 80 120 160 180 200 350 500 700
Embedment depth hef [mm] 80 90 110 115 125 170 210 250 280 340 360
Min. base material
hmin [mm] hef + 30 mm hef + 2d0
thickness
Anchor diameter d [mm] 8 10 12 14 16 20 25 28 32 36 40
Drill diameter d0 [mm] 12 14 16 18 20 24 32 35 40 46 50
Rev. 10 (EN)
PRODUCT DATA SHEET
Rev. 10 (EN)
PRODUCT DATA SHEET
2)
Shall be determined acc. to this table or clause 5.2.2.4, EOTA Technical Report TR 029. The smaller value is decisive.
3)
Long term temperature / short term temperature . Long term concrete temperatures are roughly constant over significant periods of time. Short
term elevated temperatures are those that occur over brief intervals, e.g. as a result of diurnal cycling.
Rev. 10 (EN)
PRODUCT DATA SHEET
1)
Sizes M33 up to M39 are not covered by ETA‘s.
10
Rev. 10 (EN)
PRODUCT DATA SHEET
1)
For more details, as well as values in water filled concrete see ETA-14/0352.
2)
For reinforcing bars which do not comply with DIN 488: the characteristic resistance NRk,s shall be determined acc. to Technical Report TR 029, equati-
on (5.1).
3)
Shall be determined acc. to this table or clause 5.2.2.4, EOTA Technical Report TR 029. The smaller value is decisive.
4)
Long term temperature / short term temperature. Long term concrete temperatures are roughly constant over significant periods of time. Short term
elevated temperatures are those that occur over brief intervals, e.g. as a result of diurnal cycling.
5)
Sizes 8 and 10 are covered by ETA only in non-cracked concrete. Sizes 36 and 40 are not covered by ETA‘s.
11
Rev. 10 (EN)
PRODUCT DATA SHEET
Partial safety factor (dry and wet) γMp = γMc 1,5 1,8
Embedment depth hef [mm] 80 90 110 115 125 170 210 250 280 340 360
Edge distance ccr,N [mm] 97 121 139 170 180 219 274 298 330 372 413
Spacing scr,N [mm] 2 x ccr,N
Increasing factors for concrete yc (fck0,11)/1,42
Splitting failure
Edge distance ccr,sp [mm] ccr,N ≤ 2 hef (2,5 - h/hef ) ≤ 2,4 hef
Spacing scr,sp [mm] 2 x ccr,sp
Partial safety factor
(dry and wet)
γMsp 1,8 2,1
The data in this table are intended to use together with the design provisions of ETAG Technical Report TR 029.
2)
For reinforcing bars which do not comply with DIN 488: the characteristic resistance NRk,s shall be determined acc. to Technical Report TR 029, equati-
on (5.1).
3)
Shall be determined acc. to this table or clause 5.2.2.4, EOTA Technical Report TR 029. The smaller value is decisive.
4)
Long term temperature / short term temperature. Long term concrete temperatures are roughly constant over significant periods of time. Short term
elevated temperatures are those that occur over brief intervals, e.g. as a result of diurnal cycling.
12
Rev. 10 (EN)
PRODUCT DATA SHEET
Factor k 2,0
1)
For reinforcing bars which do not comply with DIN 488: the characteristic resistance VRk,s shall be determined acc. to Technical Report TR 029,
equation (5.5).
2)
For reinforcing bars which do not comply with DIN 488: the characteristic resistance M0Rk,s shall be determined acc. to Technical Report TR 029,
equation (5.6b).
3)
Sizes 36 and 40 are not covered by ETA‘s.
13
Rev. 10 (EN)
PRODUCT DATA SHEET
a)
The values defining the seismicity levels may be found in the National Annex of EN 1998-1.
b)
Definition according to EN 1998-1:2004, 3.2.1.
c)
ag = Design ground acceleration on Type A ground (EN 1998-1: 2004, 3.2.1),
S = soil factor (see e.g. EN 1998-1: 2004, 3.2.2).
d)
C1 attachments of non-structural elements
e)
C2 for connections between structural elements of primary and/or secondary seismic members
0
with R k = NRk,s, NRk,p, NRk,c, NRk,sp (from design in cracked concrete)
αN,seis = 1,0 for NRk,c, NRk,sp
αN,seis = for NRk,s, NRk,p see following tables
αgap = see following tables
αseis = see following tables
Rk,seis = αgap • αseis • αV,seis • R k
0
Shear load:
0
with R k = VRk,s, VRk,c, VRk,cp (from design in cracked concrete)
αV,seis = 1,0 for VRk,c, VRk,cp
αV,seis = for VRk,s see following tables
αgap = see following tables
αseis = see following tables
14
Rev. 10 (EN)
PRODUCT DATA SHEET
Anchor size threaded rod 1) M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
Tension load
Steel failure (NRk,s) αN,seis [-] 1,0
Shear load
Steel failure without lever arm (VRk,s) αV,seis [-] 0,70
Shear load
Steel failure without lever arm (VRk,s) αV,seis [-] 0,70
15
Rev. 10 (EN)
PRODUCT DATA SHEET
Anchor size (steel quality 5.8) 1) M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
non-cracked
NRec,stat 8,6 13,8 20,0 28,0 38,1 52,3 67,9 80,5 98,3 113 127
concrete
24 °C/40 °C NRec,stat [kN] 6,0 8,4 12,3 16,2 21,8 29,6 39,7 49,4 62,1 74,1 87,1
cracked concrete
Recommended tension load
NRec,seis 4,1 5,7 8,4 11,0 14,8 20,4 27,4 34,1 42,8 51,1 60,1
non-cracked
NRec,stat 7,6 10,7 14,8 21,2 29,1 40,4 54,1 67,3 79,0 94,2 111
concrete
43 °C/60 °C NRec,stat [kN] 3,6 5,0 7,4 10,0 12,7 18,8 25,2 31,4 39,5 47,1 55,4
cracked concrete
NRec,seis 2,4 3,4 5,0 6,8 8,6 13,0 17,4 21,7 27,3 32,5 38,2
non-cracked
NRec,stat 6,8 9,5 13,2 18,7 25,4 37,7 46,9 58,3 67,7 80,8 95,0
concrete
43 °C/72 °C NRec,stat [kN] 3,2 4,5 6,6 8,7 10,9 16,2 21,6 26,9 33,9 40,4 47,5
cracked concrete
NRec,seis 2,2 3,1 4,5 5,9 7,4 11,1 14,9 18,6 23,4 27,9 32,8
non-cracked
VRec,stat 5,1 8,6 12,0 22,3 34,9 50,3 65,7 80,0 88,6 102 117
concrete
Recommended
shear load wit- VRec,stat [kN] 4,8 7,1 9,6 13,7 19,2 24,2 29,1 34,6 40,6 47,0 53,8
hout lever arm 2) cracked concrete
VRec,seis 1,8 3,0 4,2 6,9 9,6 12,1 14,5 17,3 20,3 23,5 26,9
Embedment depth hef [mm] 80 90 110 125 170 210 250 280 320 350 380
Edge distance ccr,N [mm] 113 135 165 188 255 304 342 379 400 436 472
16
Rev. 10 (EN)
PRODUCT DATA SHEET
Anchor size (steel quality 5.8) M8 M10 M12 M16 M20 M24 M27 M30 M33 M36 M39
non-cracked
24 °C/40 °C NRec [kN] 8,6 13,8 16,5 24,9 40,3 56,5 75,7 89,0 111,9 131 148
Recommended
concrete
tension load
non-cracked
43 °C/60 °C NRec [kN] 6,7 9,4 10,7 15,0 25,4 34,6 46,3 52,4 65,8 78,5 92,4
concrete
non-cracked
43 °C/72 °C NRec [kN] 6,2 8,1 9,9 13,7 21,2 31,4 42,1 47,1 59,2 70,7 83,1
concrete
Recommended shear
non-cracked
load without lever VRec [kN] 5,1 8,6 12,0 22,3 34,4 45,1 55,4 63,7 75,3 87,0 95,7
concrete
arm 1)
Embedment depth hef [mm] 80 90 110 125 170 210 250 280 320 350 380
Edge distance ccr,N [mm] 97 121 139 185 225 263 296 319 351 383 403
1)
Shear load with lever arm acc. TR 029.
17
Rev. 10 (EN)
PRODUCT DATA SHEET
NRec,seis 4,1 5,7 8,4 9,6 9,4 15,0 21,3 28,4 36,3 49,6 58,4
non-cracked
NRec,stat 6,8 9,5 13,2 16,1 18,7 25,4 39,3 48,6 62,2 85,0 100
concrete
43 °C/60 °C NRec,stat [kN] 3,6 5,0 7,4 8,0 8,5 12,7 19,6 26,2 33,5 45,8 53,9
cracked concrete
NRec,seis 2,4 3,4 5,0 5,5 5,8 8,8 13,5 18,1 23,1 31,6 37,2
non-cracked
NRec,stat 6,0 8,4 12,3 14,0 17,5 23,6 33,7 44,9 57,4 78,5 92,3
concrete
43 °C/72 °C NRec,stat [kN] 3,2 4,5 6,6 7,0 7,5 10,9 16,8 22,4 28,7 39,2 46,2
cracked concrete
NRec,seis 2,2 3,1 4,5 4,8 5,1 7,5 11,6 15,5 19,8 27,1 31,9
non-cracked
VRec,stat 6,7 10,5 14,8 20,0 26,2 41,0 56,6 67,0 84,0 102 120
concrete
Recommended
shear load wit- VRec,stat [kN] 4,8 7,1 9,4 11,6 13,7 19,1 25,7 30,5 38,3 46,6 55,2
hout lever arm 2) cracked concrete
VRec,seis 2,3 3,5 4,7 5,8 6,9 9,5 12,8 15,3 19,2 23,3 27,6
Embedment depth hef [mm] 80 90 110 115 125 170 210 250 280 340 360
Edge distance ccr,N [mm] 109 135 158 173 188 253 303 339 388 436 484
18
Rev. 10 (EN)
PRODUCT DATA SHEET
concrete
tension load
non-cracked
43 °C/60 °C NRec [kN] 6,8 9,5 13,2 16,1 18,7 25,4 39,3 48,6 62,2 85,0 100
concrete
non-cracked
43 °C/72 °C NRec [kN] 6,0 8,4 12,3 14,0 17,5 23,6 33,7 44,9 57,4 78,5 92,3
concrete
Recommended shear
non-cracked
load without lever VRec [kN] 6,7 10,5 14,8 20,0 26,2 41,0 60,1 68,0 85 102 116
concrete
arm 1)
Embedment depth hef [mm] 80 90 110 115 125 170 210 250 280 340 360
Edge distance ccr,N [mm] 97 121 139 162 185 225 274 298 341 383 413
1)
Shear load with lever arm acc. TR 029.
19
Rev. 10 (EN)
PRODUCT DATA SHEET
Fire resistance
(Threaded rod) in hammer-drilled holes
Fire resistance time in combination with threaded rods (M8 to M30) made of zinc plated
steel, property class 5.8 or higher as well as stainless steel A4-70.
20
Rev. 10 (EN)
PRODUCT DATA SHEET
Results shown in the table are applicable to brief periods of chemical contact with full cured adhesive (e.g. temporary contact with adhesive during a spill).
21
Rev. 10 (EN)