Renewable Energy Batteries

2017 Catalog

Deep Cycle Flooded Lead Acid (FLA) Batteries

Visit Us: Email Us: Call Us:


Www.ForeverPurePlace.com Sales@ForeverPurePlace.com +1-408-969-2688
TABLE OF CONTENTS

Battery Features………………………………………………………………… 1

Index of Available Models…………………………………………..…….. 2,3

Battery Maintenance Guide………………………………………………. 4

Industrial Battery Limited Warranty………………………………….. 5


We produce our own high performing line of ForeverPure Power
Renewable Energy Batteries. These deep cycle lead acid batteries are
designed to be regularly deeply discharged and recharged to get the most
out of a renewable energy system (solar, wind, etc.). They are able to
provide system users with an un uninterrupted power supply (UPS).
ForeverPure Power Batteries are produced in the USA, come with a 5 year
warranty, and are available in 12, 24, 36, and 48 Volt.

Tubular Positive (+) Plates, Negative (-) Plates Tubular design


and Separators cross section

Features of ForeverPure Power Batteries


• Tubular Design results in smaller footprint and greater charge retention
• Lead-Antimony Alloy provides mechanical strength and deep cycling capability
• Envelope Separator for longer life
• Tank Formation
• Bottom Bridge
• Hardigg jar for tough protection
• Flip vent caps with water level indicator
• Watering System
• At least 1,500 cycles under 80% discharge

P. 1
Available Models
Dimensions (Inches) Weight
Battery Model Volt 20 Hr. AH Rating X Y Z (Wet)
(Length) (Width) (Height) (Lbs)
6-85-13.wc.FLA 12 816 30.88 7.45 23.25 507
12-75-5.wc.FLA 24 240 24.60 6.42 23.46 333
12-85-5.wc.FLA 24 240 25.91 5.75 23.23 349
12-85-7-b.wc.FLA 24 408 25.60 8.50 23.25 472
12-85-13.wc.FLA 24 816 30.50 13.00 23.25 941
12-85-15.FLA 24 952 35.25 13.00 22.64 1090
12-100-13.wc.FLA 24 960 30.50 13.00 26.25 1080
12-125-13-a.FLA 24 1200 35.56 11.56 31.38 1241
12-125-13-b.FLA 24 1200 30.50 13.00 30.50 1287
12-125-15-a.FLA 24 1400 38.00 11.90 30.50 1446
12-125-15-b.FLA 24 1400 36.00 14.00 30.50 1468
12-125-17.FLA 24 1600 38.00 13.50 30.50 1624
18-85-13-a.FLA 36 816 38.00 15.60 22.64 1306
18-85-13-b.FLA 36 816 30.63 19.00 22.63 1306
18-85-15-a.FLA 36 952 38.00 17.80 22.64 1556
18-85-15-b.FLA 36 952 32.00 23.60 22.64 1556
18-85-17-a.FLA 36 1088 38.00 20.00 22.64 1747
18-85-17-b.FLA 36 1088 32.50 25.60 22.64 1785
18-85-19-a.FLA 36 1224 38.20 22.30 22.64 1990
18-85-19-b.FLA 36 1224 35.00 25.56 22.63 1990

18-85-17-a.FLA 12-85-5.FLA

12-125-17.FLA
12-85-13.FLA
P. 2
Available Models
Dimensions (Inches) Weight
Battery Model Volt 20 Hr. AH Rating X Y Z (Wet)
(Length) (Width) (Height) (Lbs)
18-85-21.FLA 36 1360 38.20 24.60 22.64 2167
18-85-23.FLA 36 1496 38.20 27.00 22.64 2325
18-85-25.FLA 36 1632 38.20 29.25 22.64 2510
18-85-27.FLA 36 1768 38.50 31.75 22.64 2651
18-125-11.FLA 36 1000 37.80 13.60 30.50 1640
18-125-15.FLA 36 1400 38.00 17.80 30.50 2116
18-125-17.FLA 36 1600 38.00 20.00 30.50 2392
24-85-9.FLA 48 544 31.56 17.95 23.25 1180
24-85-13-a.FLA 48 816 38.00 20.50 22.64 1825
24-85-15-a.FLA 48 952 38.20 23.60 22.64 2064
24-85-17.FLA 48 1088 38.20 26.50 22.64 2301
24-85-19.FLA 48 1224 38.20 29.75 22.64 2632
24-85-21.FLA 48 1360 38.20 32.75 22.64 2887
24-85-25-a.FLA 48 1632 38.75 38.25 23.27 3620
24-85-25-b.FLA 48 1632 57.75 25.75 23.27 3490
24-85-27.FLA 48 1768 41.75 38.25 23.27 3563
24-125-11.FLA 48 1000 37.90 17.70 31.10 2245
24-125-13-a.FLA 48 1200 37.88 20.56 30.50 TBA
24-125-17.FLA 48 1600 44 26.69 30.56 3643

18-85-21.FLA 18-125-13.FLA

24-85-21.FLA
P. 3
Battery Maintenance Guide

General Caring
• Do not discharge (drain) batteries over 70% of rated capacity. (1.140 -1.160 SPG)
• Do not use batteries with specific gravity below 1120
• Properly charge batteries with matched chargers. Do not undercharge or overcharge the battery.
(Voltage, A.H. and type. Max overall AH variance of 10%)
• Always allow your battery to cool down after charging. (Ideal usage: 70% discharge, 6-8 hours
charge time, 4 hours cool down time)
• Contact your Battery Service Representative (BSR) for an inspection if batteries on-charge exceeds
115 degrees F.
• Report any issues (even minor) to your BSR.
Watering
• Add water only as needed to maintain proper electrolyte (acid) level. (Approximately 0.25” below
bottom of vent opening, but above the element protector)
• Always water after charging. (This will help prevent spill overs)
• Only distilled or other approved water sources (e.g. deionized) should be used.
Safety
• Always wear safety equipment when inspecting, servicing or working near batteries.
• Major electrolyte spill-overs should be reported to your battery service company as they can affect
battery performance and may possibly contain sulfuric acid, lead compounds.
• Never add acid to battery, only approved water. (Acid adjustment svc. is available)
• Always keep vent caps tightly in place. (Removal is fine while watering)
• Open battery and truck covers during charge and ensure adequate ventilation exists in all areas
where batteries are being charged.
• Batteries will produce a flammable/explosive gasses. Never smoke, allow sparks, or allow any open
flame near a battery.
• Always ensure no metal objects come into contact with the inter-cell connectors, or cable ends of a
battery.
• Always keep batteries clean, dry, and free from foreign objects.

P. 4
Industrial Battery Limited Warranty
ForeverPure Corporation warrants their industrial batteries against defects in materials and workmanship for a
period of five (5) years from the date of receipt for batteries containing nine (9) or more plates, and for a period of
three (3) years for batteries containing five (5) to seven (7) plates.

During the warranty period, if a battery fails to supply 80% of the six (6) hour rated capacity when tested under
supervision and according to standards, it shall be repaired or replaced at ForeverPure Corporation's discretion.
There will be part(s) replacement only; all other expenses will not be included. The replacement battery shall only
be warranted for the remainder of the unused portion of the original battery warranty. Credit for any defective
battery shall be prorated based upon the original purchase price, the length of the warranty, and the time
remaining on the warranty.

Additional Terms and Conditions:

1. Each battery is of the proper size, design, and capacity for the duty cycle it is intended
to perform and shall never exceed that value during the warranty period.
2. Batteries are to be limited to one cycle charge and discharge within a twenty-four (24)
hour day of no more than 80% of the rated capacity, and no more than 300 cycles per
calendar year.
3. Each battery is to be charged on an approved and properly sized charger that meets or
exceeds the latest BCI Standards, for industrial truck chargers. Chargers are required to
have the proper capacity rating, voltages and charging start and finish rates to completely
recharge the battery to specified specific gravity before subsequent discharge.
Recharging must occur during the twenty-four hour, per Note 2 above.
4. Maintenance and cycle records shall be kept in accordance to manufacturer’s guidelines.
Such records must be submitted to ForeverPure Corporation at the time of the warranty
claim in order to qualify for protection under the warranty requirements.
5. Sufficient electrolyte levels must be maintained in each cell at all times by the addition
of approved purified water with TDS (Total Dissolved Solids) less than 50 ppm. The
addition of acid or other additives voids this warranty.
6. This warranty is void should average electrolyte temperatures be in excess of 115° F, or
below 50° F.
7. This warranty is void should it be determined that any battery(s) has been modified,
abused, misused, or damaged by anything other than by normal use.
8. This warranty is void should repairs be performed by anyone other than ForeverPure
Corporation., or one of its designated service representatives.
9. This warranty applies to the original owner only and is non-transferrable.
10. This warranty is not applicable and void for batteries used in heavy-duty applications such
as, but not limited to, mill, foundry, and forging operations.

THIS WARRANTY EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED, INCLUDING,
WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS. FOREVERPURE
CORPORATION ASSUMES NO LIABILITY FOR ANY PERSONAL INJURY OR PROPERTY DAMAGE OF ANY
KIND WHETHER INCIDENTAL, CONSEQUENTIAL, OR OTHERWISE, FROM THE POSSESSION OR THE USE
OF THE BATTERY(S). NO CLAIM SHALL EVER EXCEED THE PURCHASE PRICE OF THE BATTERY(S).

P. 5

You might also like